Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.
ERIC Educational Resources Information Center
Pike, R. M.; And Others
1986-01-01
Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)
Direct conversion of rheological compliance measurements into storage and loss moduli.
Evans, R M L; Tassieri, Manlio; Auhl, Dietmar; Waigh, Thomas A
2009-07-01
We remove the need for Laplace/inverse-Laplace transformations of experimental data, by presenting a direct and straightforward mathematical procedure for obtaining frequency-dependent storage and loss moduli [G'(omega) and G''(omega), respectively], from time-dependent experimental measurements. The procedure is applicable to ordinary rheological creep (stress-step) measurements, as well as all microrheological techniques, whether they access a Brownian mean-square displacement, or a forced compliance. Data can be substituted directly into our simple formula, thus eliminating traditional fitting and smoothing procedures that disguise relevant experimental noise.
Direct conversion of rheological compliance measurements into storage and loss moduli
NASA Astrophysics Data System (ADS)
Evans, R. M. L.; Tassieri, Manlio; Auhl, Dietmar; Waigh, Thomas A.
2009-07-01
We remove the need for Laplace/inverse-Laplace transformations of experimental data, by presenting a direct and straightforward mathematical procedure for obtaining frequency-dependent storage and loss moduli [ G'(ω) and G″(ω) , respectively], from time-dependent experimental measurements. The procedure is applicable to ordinary rheological creep (stress-step) measurements, as well as all microrheological techniques, whether they access a Brownian mean-square displacement, or a forced compliance. Data can be substituted directly into our simple formula, thus eliminating traditional fitting and smoothing procedures that disguise relevant experimental noise.
ERIC Educational Resources Information Center
Birk, James P., Ed.
1989-01-01
Presented is a simple laboratory set-up for teaching microprocessor-controlled data acquisition as a part of an instrumental analysis course. Discussed are the experimental set-up, experimental procedures, and technical considerations for this technique. (CW)
Experimental calibration procedures for rotating Lorentz-force flowmeters
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.; ...
2017-07-14
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Experimental calibration procedures for rotating Lorentz-force flowmeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Simple Apparatus for Measuring the Critical Properties of Gases
ERIC Educational Resources Information Center
Donaldson, G. B.
1973-01-01
Describes the construction and operational procedures of a simple setup which enables undergraduate students to conduct experiments on critical phenomena in gases. Indicates that the experimental features are proved comparable to those of the Reamer and Sage apparatus. (CC)
A More Rigorous Quasi-Experimental Alternative to the One-Group Pretest-Posttest Design.
ERIC Educational Resources Information Center
Johnson, Craig W.
1986-01-01
A simple quasi-experimental design is described which may have utility in a variety of applied and laboratory research settings where ordinarily the one-group pretest-posttest pre-experimental design might otherwise be the procedure of choice. The design approaches the internal validity of true experimental designs while optimizing external…
Salas, Rosa Ana; Pleite, Jorge
2013-01-01
We propose a specific procedure to compute the inductance of a toroidal ferrite core as a function of the excitation current. The study includes the linear, intermediate and saturation regions. The procedure combines the use of Finite Element Analysis in 2D and experimental measurements. Through the two dimensional (2D) procedure we are able to achieve convergence, a reduction of computational cost and equivalent results to those computed by three dimensional (3D) simulations. The validation is carried out by comparing 2D, 3D and experimental results. PMID:28809283
An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.
ERIC Educational Resources Information Center
Moehs, Peter J.; Levine, Samuel
1982-01-01
A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…
Experimental Investigation of the Flow on a Simple Frigate Shape (SFS)
Mora, Rafael Bardera
2014-01-01
Helicopters operations on board ships require special procedures introducing additional limitations known as ship helicopter operational limitations (SHOLs) which are a priority for all navies. This paper presents the main results obtained from the experimental investigation of a simple frigate shape (SFS) which is a typical case of study in experimental and computational aerodynamics. The results obtained in this investigation are used to make an assessment of the flow predicted by the SFS geometry in comparison with experimental data obtained testing a ship model (reduced scale) in the wind tunnel and on board (full scale) measurements performed on a real frigate type ship geometry. PMID:24523646
Enzyme Activity Experiments Using a Simple Spectrophotometer
ERIC Educational Resources Information Center
Hurlbut, Jeffrey A.; And Others
1977-01-01
Experimental procedures for studying enzyme activity using a Spectronic 20 spectrophotometer are described. The experiments demonstrate the effect of pH, temperature, and inhibitors on enzyme activity and allow the determination of Km, Vmax, and Kcat. These procedures are designed for teaching large lower-level biochemistry classes. (MR)
Psychological Distance to Reward: Effects of S+ Duration and the Delay Reduction It Signals
ERIC Educational Resources Information Center
Alessandri, Jerome; Stolarz-Fantino, Stephanie; Fantino, Edmund
2011-01-01
A concurrent-chains procedure was used to examine choice between segmented (two-component chained schedules) and unsegmented schedules (simple schedules) in terminal links with equal inter-reinforcement intervals. Previous studies using this kind of experimental procedure showed preference for unsegmented schedules for both pigeons and humans. In…
Archimedes' Principle in Action
ERIC Educational Resources Information Center
Kires, Marian
2007-01-01
The conceptual understanding of Archimedes' principle can be verified in experimental procedures which determine mass and density using a floating object. This is demonstrated by simple experiments using graduated beakers. (Contains 5 figures.)
A Simple Lightning Flash Polarity Discriminating Counter.
ERIC Educational Resources Information Center
Devan, K. R. S.; Jayaratne, E. R.
1990-01-01
Described are the apparatus and procedures needed for a demonstration of a determination of the polarity of charges carried by individual ground flashes of lightning. Discussed are materials, apparatus construction, and experimental results. (CW)
Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions
NASA Astrophysics Data System (ADS)
Li, Er Qiang; Zhang, Jia Ming; Thoroddsen, Sigurdur T.
2014-01-01
Droplet-based microfluidic devices have become a preferred versatile platform for various fields in physics, chemistry and biology. Polydimethylsiloxane soft lithography, the mainstay for fabricating microfluidic devices, usually requires the usage of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions. The advantages of our method lie in a simple manufacturing procedure, inexpensive processing equipment and flexibility in the surface modification of the designed microfluidic devices. Different types of devices have been designed and tested and the experimental results demonstrated their robustness for preparing monodisperse single, double, triple and multi-component emulsions.
A comparison of methods for teaching receptive language to toddlers with autism.
Vedora, Joseph; Grandelski, Katrina
2015-01-01
The use of a simple-conditional discrimination training procedure, in which stimuli are initially taught in isolation with no other comparison stimuli, is common in early intensive behavioral intervention programs. Researchers have suggested that this procedure may encourage the development of faulty stimulus control during training. The current study replicated previous work that compared the simple-conditional and the conditional-only methods to teach receptive labeling of pictures to young children with autism spectrum disorder. Both methods were effective, but the conditional-only method required fewer sessions to mastery. © Society for the Experimental Analysis of Behavior.
Two Experiments for Estimating Free Convection and Radiation Heat Transfer Coefficients
ERIC Educational Resources Information Center
Economides, Michael J.; Maloney, J. O.
1978-01-01
This article describes two simple undergraduate heat transfer experiments which may reinforce a student's understanding of free convection and radiation. Apparatus, experimental procedure, typical results, and discussion are included. (Author/BB)
De Flora, Silvio
1974-01-01
Areas of cytopathic effect can be circumscribed in cell monolayers by adding antiserum to the liquid nutrient medium after adsorption of virus. This procedure represents a simple and reliable tool for the titration of virus infectivity and provides an experimental model for studying some aspects of virus infection. Images PMID:4364462
Test Equality between Three Treatments under an Incomplete Block Crossover Design.
Lui, Kung-Jong
2015-01-01
Under a random effects linear additive risk model, we compare two experimental treatments with a placebo in continuous data under an incomplete block crossover trial. We develop three test procedures for simultaneously testing equality between two experimental treatments and a placebo, as well as interval estimators for the mean difference between treatments. We apply Monte Carlo simulations to evaluate the performance of these test procedures and interval estimators in a variety of situations. We note that the bivariate test procedure accounting for the dependence structure based on the F-test is preferable to the other two procedures when there is only one of the two experimental treatments has a non-zero effect vs. the placebo. We note further that when the effects of the two experimental treatments vs. a placebo are in the same relative directions and are approximately of equal magnitude, the summary test procedure based on a simple average of two weighted-least-squares (WLS) estimators can outperform the other two procedures with respect to power. When one of the two experimental treatments has a relatively large effect vs. the placebo, the univariate test procedure with using Bonferroni's equality can be still of use. Finally, we use the data about the forced expiratory volume in 1 s (FEV1) readings taken from a double-blind crossover trial comparing two different doses of formoterol with a placebo to illustrate the use of test procedures and interval estimators proposed here.
Determination of Components in Beverages by Thin-Layer Chromatography.
ERIC Educational Resources Information Center
Ma, Yinfa; Yeung, Edward S.
1990-01-01
Described is a simple and interesting chromatography experiment using three different fluorescence detection principles for the determination of caffeine, saccharin and sodium benzoate in beverages. Experimental procedures and an analysis and discussion of the results are included. (CW)
Approximate solution of the multiple watchman routes problem with restricted visibility range.
Faigl, Jan
2010-10-01
In this paper, a new self-organizing map (SOM) based adaptation procedure is proposed to address the multiple watchman route problem with the restricted visibility range in the polygonal domain W. A watchman route is represented by a ring of connected neuron weights that evolves in W, while obstacles are considered by approximation of the shortest path. The adaptation procedure considers a coverage of W by the ring in order to attract nodes toward uncovered parts of W. The proposed procedure is experimentally verified in a set of environments and several visibility ranges. Performance of the procedure is compared with the decoupled approach based on solutions of the art gallery problem and the consecutive traveling salesman problem. The experimental results show the suitability of the proposed procedure based on relatively simple supporting geometrical structures, enabling application of the SOM principles to watchman route problems in W.
How-to-Do-It: Using the Muscle Response Phenomenon to Enhance Biology Teaching.
ERIC Educational Resources Information Center
Kendler, Barry S.
1989-01-01
Presents a method which introduces biology students to some fundamental aspects of scientific methodology. Explains simple muscle testing procedures, a historical perspective, experimental variables, pedagogical uses, and possible mechanisms of the muscle response phenomenon action. (RT)
In Vitro Spermatogenesis of Gypsy Moth Larvae.
ERIC Educational Resources Information Center
Brown, Judy; Loeb, Marcia J.
1994-01-01
Students establish simple cell developmental cultures to observe the process of spermatogenesis, mitosis, and meiosis in living cells. Using the background information, hints for further exploration, and experimental procedures provided, teachers can easily modify this experiment to suit their students needs. (ZWH)
ERIC Educational Resources Information Center
King, Allen L.
1975-01-01
Describes an experimental project on boomerangs designed for an undergraduate course in classical mechanics. The students designed and made their own boomerangs, devised their own procedures, and carried out suitable measurements. Presents some of their data and a simple analysis for the two-bladed boomerang. (Author/MLH)
Experiments in Horticultural Science.
ERIC Educational Resources Information Center
Arbel, Illil
1992-01-01
Investigates the use of temperature and light to change the usual intervals for plant germinating, sprouting, and flowering. Provides simple experimental procedures and discussions regarding photoperiodism, forced branching before spring, and various types of seed dormancy, including physical dormancy, physiological dormancy, and double dormancy.…
ERIC Educational Resources Information Center
Matlen, Bryan J.; Klahr, David
2013-01-01
We report the effect of different sequences of high vs low levels of instructional guidance on children's immediate learning and long-term transfer of simple experimental design procedures and concepts, often called "CVS" (Control of Variables Strategy). Third-grade children (N = 57) received instruction in CVS via one of four possible orderings…
NASA Astrophysics Data System (ADS)
Thubagere, Anupama J.; Thachuk, Chris; Berleant, Joseph; Johnson, Robert F.; Ardelean, Diana A.; Cherry, Kevin M.; Qian, Lulu
2017-02-01
Biochemical circuits made of rationally designed DNA molecules are proofs of concept for embedding control within complex molecular environments. They hold promise for transforming the current technologies in chemistry, biology, medicine and material science by introducing programmable and responsive behaviour to diverse molecular systems. As the transformative power of a technology depends on its accessibility, two main challenges are an automated design process and simple experimental procedures. Here we demonstrate the use of circuit design software, combined with the use of unpurified strands and simplified experimental procedures, for creating a complex DNA strand displacement circuit that consists of 78 distinct species. We develop a systematic procedure for overcoming the challenges involved in using unpurified DNA strands. We also develop a model that takes synthesis errors into consideration and semi-quantitatively reproduces the experimental data. Our methods now enable even novice researchers to successfully design and construct complex DNA strand displacement circuits.
Garcia, F; Arruda-Neto, J D; Manso, M V; Helene, O M; Vanin, V R; Rodriguez, O; Mesa, J; Likhachev, V P; Filho, J W; Deppman, A; Perez, G; Guzman, F; de Camargo, S P
1999-10-01
A new and simple statistical procedure (STATFLUX) for the calculation of transfer coefficients of radionuclide transport to animals and plants is proposed. The method is based on the general multiple-compartment model, which uses a system of linear equations involving geometrical volume considerations. By using experimentally available curves of radionuclide concentrations versus time, for each animal compartment (organs), flow parameters were estimated by employing a least-squares procedure, whose consistency is tested. Some numerical results are presented in order to compare the STATFLUX transfer coefficients with those from other works and experimental data.
Let's Measure the Dielectric Constant of a Piece of Paper!
ERIC Educational Resources Information Center
Karlow, Edwin A.
1991-01-01
Described is a simple circuit with which students can observe the effect of common dielectric materials in a capacitor and measure the dielectric constant of a piece of paper. Discussed are the theory, apparatus construction, and experimental procedures for this activity. (CW)
ERIC Educational Resources Information Center
Cardinali, Mario Emilio; Giomini, Claudio
1989-01-01
Proposes a simple procedure based on an expansion of the exponential terms of Raoult's law by applying it to the case of the benzene-toluene mixture. The results with experimental values are presented as a table. (YP)
Vitamin C: Rate of Decay and Stability Characteristics
ERIC Educational Resources Information Center
Kakis, Frederic J.; Rossi, Carl J.
1974-01-01
Describes an experiment designed to provide the opportunity for studying some of the parameters affecting the stability of Vitamin C in various environments, and to acquaint the student with an experimental procedure for studying simple reaction kinetics and the calculations of specific rate constants. (Author/JR)
Technical Note: Procedure for the calibration and validation of kilo-voltage cone-beam CT models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vilches-Freixas, Gloria; Létang, Jean Michel; Rit,
2016-09-15
Purpose: The aim of this work is to propose a general and simple procedure for the calibration and validation of kilo-voltage cone-beam CT (kV CBCT) models against experimental data. Methods: The calibration and validation of the CT model is a two-step procedure: the source model then the detector model. The source is described by the direction dependent photon energy spectrum at each voltage while the detector is described by the pixel intensity value as a function of the direction and the energy of incident photons. The measurements for the source consist of a series of dose measurements in air performedmore » at each voltage with varying filter thicknesses and materials in front of the x-ray tube. The measurements for the detector are acquisitions of projection images using the same filters and several tube voltages. The proposed procedure has been applied to calibrate and assess the accuracy of simple models of the source and the detector of three commercial kV CBCT units. If the CBCT system models had been calibrated differently, the current procedure would have been exclusively used to validate the models. Several high-purity attenuation filters of aluminum, copper, and silver combined with a dosimeter which is sensitive to the range of voltages of interest were used. A sensitivity analysis of the model has also been conducted for each parameter of the source and the detector models. Results: Average deviations between experimental and theoretical dose values are below 1.5% after calibration for the three x-ray sources. The predicted energy deposited in the detector agrees with experimental data within 4% for all imaging systems. Conclusions: The authors developed and applied an experimental procedure to calibrate and validate any model of the source and the detector of a CBCT unit. The present protocol has been successfully applied to three x-ray imaging systems. The minimum requirements in terms of material and equipment would make its implementation suitable in most clinical environments.« less
If Oswald Hadn’t Used Counterfactuals, My Robot Would Have
2010-02-05
procedure can be viewed as a concrete implementation of Ramsey’s idea ( Ramsey , 1929), according to which a conditional is accepted if the consequent is...been treated (x′). This fraction cannot be assessed in experimental study, for the simple reason that we cannot re- test patients twice, with and...without treatment. A different question is therefore posed: which counterfactuals can be tested , be it in experimental or observational studies. This
Evaluation of hard red spring wheat quality using four different roller mills
USDA-ARS?s Scientific Manuscript database
Domestic and overseas buyers pay premium price for hard red spring (HRS) wheat due to high protein content and excellent milling and baking performances. For efficient quality identification of wheat samples, a wheat quality laboratory needs an objective and simple experimental milling procedure and...
RADIOISOTOPE EXPERIMENTS IN HIGH SCHOOL BIOLOGY, AN ANNOTATED SELECTED BIBLIOGRAPHY.
ERIC Educational Resources Information Center
HURLBURT, EVELYN M.
SELECTED REFERENCES ON THE USE OF RADIOISOTOPES IN BIOLOGY ARE CONTAINED IN THIS ANNOTATED BIBLIOGRAPHY FOR SECONDARY SCHOOL STUDENTS. MATERIALS INCLUDED WERE PUBLISHED AFTER 1960 AND DEAL WITH THE PROPERTIES OF RADIATION, SIMPLE RADIATION DETECTION PROCEDURES, AND TECHNIQUES FOR USING RADIOISOTOPES EXPERIMENTALLY. THE REFERENCES ARE LISTED IN…
How to Learn and Have Fun with Poly(Vinyl Alcohol) and White Glue.
ERIC Educational Resources Information Center
de Zea Bermudez, V.; Passos de Almeida, P.; Feria Seita, J.
1998-01-01
Presents a classroom guide for a simple theoretical approach to the study of certain fluids. Discusses background information, followed by experimental procedures for the preparation of two popular viscoelastic materials ("Slime" and "Silly Putty") that exhibit unusual flow properties. Also lists student discussion questions…
1991-05-01
was received as bar stocks in the work hardened condition. Before machining, the copper rods were annealed at 400 °C in argon for one hour. This...ABSTRACT Large deformation uniaxial compression and fixed-end torsion (simple shear) experiments were conducted on annealed OFHC Copper to obtain its... annealing treatment produced an average grain diameter of 45 jim. Experimental Procedure Compression Tests All the compression tests were conducted with
Regional thermal-inertia mapping from an experimental satellite ( Powder River basin, Wyoming).
Watson, K.
1982-01-01
A new experimental satellite has provided, for the first time, thermal data that should be useful in reconnaissance geologic exploration. Thermal inertia, a property of geologic materials, can be mapped from these data by applying an algorithm that has been developed using a new thermal model. A simple registration procedure was used on a pair of day and night images of the Powder River basin, Wyoming, to illustrate the method.-from Author
Nano-Ignition Torch Applied to Cryogenic H2/O2 Coaxial Jet
2016-01-04
developed and ignition of liquid fuel sprays by the torch has been achieved. In this report, we will describe the experimental procedure for producing...ignition that is induced by a compact Xe-flash, including the results for photoignition of a simple fuel spray in air as well as ignition of a coaxial...window. Experimental Setup for Fuel Spray Ignition Three different setups were utilized for the fuel ignition experiments. The first one was used
A Simple Experiment to Explore Standing Waves in a Flexible Corrugated Sound Tube
NASA Astrophysics Data System (ADS)
Amorim, Maria Eva; Sousa, Teresa Delmira; Carvalho, P. Simeão; Sousa, Adriano Sampaioe
2011-09-01
Sound tubes, pipes, and singing rods are used as musical instruments and as toys to perform amusing experiments. In particular, corrugated tubes present unique characteristics with respect to the sounds they can produce; that is why they have been studied so intensively, both at theoretical and experimental levels.1-4 Experimental studies usually involve expensive and sophisticated equipment that is out of reach of school laboratory facilities.3-6 In this paper we show how to investigate quantitatively the sounds produced by a flexible sound tube corrugated on the inside by using educational equipment readily available in school laboratories, such as the oscilloscope, the microphone, the anemometer, and the air pump. We show that it is possible for students to study the discontinuous spectrum of sounds produced by a flexible corrugated tube and go even further, computing the speed of sound in air with a simple experimental procedure.
In Vivo Effects of Barbituates on Seed Germination and Seedling Growth.
ERIC Educational Resources Information Center
Kordan, H. A.
1984-01-01
A simple, low-cost experimental system can be used to demonstrate the "in vivo" effects of barbituates on seed germination and seedling growth behavior in different plant species. Lipid solubility and concentration of individual barbituates both affect the response. List of materials needed, procedures used, and typical results obtained are…
A Materials Index--Its Storage, Retrieval, and Display
ERIC Educational Resources Information Center
Rosen, Carol Z.
1973-01-01
An experimental procedure for indexing physical materials based on simple syntactical rules was tested by encoding the materials in the journal, Applied Physics Letters,'' to produce a materials index. The syntax and numerous examples together with an indication of the method by which retrieval can be effected are presented. (5 references)…
A Standardized Soil Ecotoxicological Test Using Red Worms (Eisenia fetida).
ERIC Educational Resources Information Center
Paradise, Christopher J.
2001-01-01
Describes a simple, inexpensive test for soil contamination that can be used in a variety of courses to examine the effects of soil toxicity, to practice standardized laboratory procedures, to study experimental design and data analysis, or to investigate earthworm ecology. Presents background information along with details regarding equipment,…
Cardiac Arrhythmias in Experimental Syncope
1958-11-01
cardiac toward respiratory alkalosis . Regardless of arriythmias by stress procedures. It follows these two extremes in the assumed change in that previous...frequently induced by respiratory maneuvers without syncope. Intravenous aidministration of atropine appatently prevented recurrence of cardiac...arrhythmia induced by respiratory maneuvers. Significant cardiac arrhythmia was also noted in simple orthostatic syncope. Loss of consciousness presents a
Low carbon steel: Metallurgical structure vs. mechanical properties
NASA Technical Reports Server (NTRS)
Shull, Robert D.
1990-01-01
The objective is to provide a low cost, simple experiment for either demonstration purposes or as a laboratory experiment that will teach the student the importance of the thermal-mechanical history of a metallic alloy in determining that material's mechanical behavior. Hairpins are subjected to various treatments. The experimental equipment and procedures are discussed.
Cavity Ring down Spectroscopy Experiment for an Advanced Undergraduate Laboratory
ERIC Educational Resources Information Center
Stacewicz, T.; Wasylczyk, P.; Kowalczyk, P.; Semczuk, M.
2007-01-01
A simple experiment is described that permits advanced undergraduates to learn the principles and applications of the cavity ring down spectroscopy technique. The apparatus is used for measurements of low concentrations of NO[subscript 2] produced in air by an electric discharge. We present the setup, experimental procedure, data analysis and some…
The effect of music on parental participation during pediatric laceration repair.
Sobieraj, Gregory; Bhatt, Maala; LeMay, Sylvie; Rennick, Janet; Johnston, Celeste
2009-12-01
The purpose of this quasi-experimental study was to test an intervention on the use of music during simple laceration repair to promote parent-led distraction in children aged 1 to 5. Children's songs were broadcast via speakers during laceration repair and parents were encouraged to participate in distracting their child. The proportion of parental participation was determined. Laceration procedures were videotaped and objectively scored using the Procedure Behavior Check List. A total of 57 children participated in the study. There was no difference in parental involvement between the control and intervention groups. When age, sex, and condition were controlled for, distress scores were significantly higher if the father was present in the procedure room than if only the mother was present (43.68 vs. 23.39, t(54) 4.296, p = < 0.001). It was concluded that distress varies with the age of the child and the parent who is present during the procedure. Providing music during simple laceration repair did not increase the proportion of parents who were involved in distraction.
NASA Technical Reports Server (NTRS)
Harris, J. E.
1975-01-01
An implicit finite-difference procedure is presented for solving the compressible three-dimensional boundary-layer equations. The method is second-order accurate, unconditionally stable (conditional stability for reverse cross flow), and efficient from the viewpoint of computer storage and processing time. The Reynolds stress terms are modeled by (1) a single-layer mixing length model and (2) a two-layer eddy viscosity model. These models, although simple in concept, accurately predicted the equilibrium turbulent flow for the conditions considered. Numerical results are compared with experimental wall and profile data for a cone at an angle of attack larger than the cone semiapex angle. These comparisons clearly indicate that the numerical procedure and turbulence models accurately predict the experimental data with as few as 21 nodal points in the plane normal to the wall boundary.
On the nitrogen-induced far-infrared absorption spectra
NASA Technical Reports Server (NTRS)
Dore, P.; Filabozzi, A.
1987-01-01
The rototranslational absorption spectrum of gaseous N2 is analyzed, considering quadrupolar and hexadecapolar induction mechanisms. The available experimental data are accounted for by using a line-shape analysis in which empirical profiles describe the single-line translational profiles. Thus, a simple procedure is derived that allows the prediction of the N2 spectrum at any temperature. On the basis of the results obtained for the pure gas, a procedure to compute the far-infrared spectrum of the N2-Ar gaseous mixture is also proposed. The good agreement between computed and experimental N2-Ar data indicates that it is possible to predict the far-infrared absorption induced by N2 on the isotropic polarizability of any interacting partner.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vonach, H.; Tagesen, S.
Starting with a discussion of the requirements and goals for high quality general-purpose evaluations the paper will describe the procedures chosen in our evaluation work for JEFF for producing new general evaluations with complete covariance information for all cross sections (file 3 data). Key problems essential for the goal of making the best possible use of the existing theoretical and experimental knowledge on neutron interactions with the respective nuclide will be addressed, especially the problem of assigning covariances to calculated cross sections, necessary checking procedures for all experimental data and various possibilities to amend the experimental database beyond the obviousmore » use of EXFOR data for the respective cross sections. In this respect both, the use of elemental cross sections in isotopic evaluations and the use of implicit cross-section data (that is data which can be converted into cross sections by simple methods) will be discussed in some detail.« less
Preparation and Analysis of Positioned Mononucleosomes
Kulaeva, Olga; Studitsky, Vasily M.
2016-01-01
Short DNA fragments containing single nucleosomes have been extensively employed as simple model experimental systems for analysis of many intranuclear processes, including binding of proteins to nucleosomes, covalent histone modifications, transcription, DNA repair and ATP-dependent chromatin remodeling. Here we describe several recently developed procedures for obtaining and analysis of mononucleosomes assembled on 200–350-bp DNA fragments. PMID:25827872
Contact angle determination procedure and detection of an invisible surface film
NASA Technical Reports Server (NTRS)
Meyer, G.; Grat, R.
1990-01-01
The contact angle value, i.e., the tangent angle of liquid resting on a planar solid surface, is a basic parameter which can be applied to a wide range of applications. The goal is to provide a basic understanding of the contact angle measurement technique and to present a simple illustration that can be applied as a quality control method; namely, detection of a surface contaminant which exists on a surface that appears clean to the unaided eye. The equipment and experimental procedures are detailed.
Channel Temperature Estimates for Microwave AlGaN/GaN Power HEMTS on SiC and Sapphire
NASA Technical Reports Server (NTRS)
Freeman, Jon C.
2003-01-01
A simple technique to estimate the channel temperature of a generic AlGaN/GaN HEMTs on SiC or Sapphire, while incorporating temperature dependence of the thermal conductivity is presented. The procedure is validated b y comparing it's predictions with the experimentally measured temperatures in devices presented in three recently published articles.
NASA Astrophysics Data System (ADS)
Palazzi, E.
The evaluation of atmospheric dispersion of a cloud, arising from a sudden release of flammable or toxic materials, is an essential tool for properly designing flares, vents and other safety devices and to quantify the potential risk related to the existing ones or arising from the various kinds of accidents which can occur in chemical plants. Among the methods developed to treat the important case of upward-directed jets, Hoehne's procedure for determining the behaviour and extent of flammability zone is extensively utilized, particularly concerning petrochemical plants. In a previous study, a substantial simplification of the aforesaid procedure was achieved, by correlating the experimental data with an empirical formula, allowing to obtain a mathematical description of the boundaries of the flammable cloud. Following a theoretical approach, a most general model is developed in the present work, applicable to the various kinds of design problems and/or risk evaluation regarding upward-directed releases from high velocity sources. It is also demonstrated that the model gives conservative results, if applied outside the range of the Hoehne's experimental conditions. Moreover, with simple modifications, the same approach could be easily applied to deal with the atmospheric dispersion of anyhow directed releases.
Kreil, David P; Russell, Roslin R
2005-03-01
To overcome random experimental variation, even for simple screens, data from multiple microarrays have to be combined. There are, however, systematic differences between arrays, and any bias remaining after experimental measures to ensure consistency needs to be controlled for. It is often difficult to make the right choice of data transformation and normalisation methods to achieve this end. In this tutorial paper we review the problem and a selection of solutions, explaining the basic principles behind normalisation procedures and providing guidance for their application.
Grow, Laura L; Kodak, Tiffany; Carr, James E
2014-01-01
Previous research has demonstrated that the conditional-only method (starting with a multiple-stimulus array) is more efficient than the simple-conditional method (progressive incorporation of more stimuli into the array) for teaching receptive labeling to children with autism spectrum disorders (Grow, Carr, Kodak, Jostad, & Kisamore,). The current study systematically replicated the earlier study by comparing the 2 approaches using progressive prompting with 2 boys with autism. The results showed that the conditional-only method was a more efficient and reliable teaching procedure than the simple-conditional method. The results further call into question the practice of teaching simple discriminations to facilitate acquisition of conditional discriminations. © Society for the Experimental Analysis of Behavior.
NASA Technical Reports Server (NTRS)
Wilkenfeld, J. M.; Judge, R. J. R.; Harlacher, B. L.
1982-01-01
A combined experimental and analytical program to develop system electrical test procedures for the qualification of spacecraft against damage produced by space-electron-induced discharges (EID) occurring on spacecraft dielectric outer surfaces is described. The data on the response of a simple satellite model, called CAN, to electron-induced discharges is presented. The experimental results were compared to predicted behavior and to the response of the CAN to electrical injection techniques simulating blowoff and arc discharges. Also included is a review of significant results from other ground tests and the P78-2 program to form a data base from which is specified those test procedures which optimally simulate the response of spacecraft to EID. The electrical and electron spraying test data were evaluated to provide a first-cut determination of the best methods for performance of electrical excitation qualification tests from the point of view of simulation fidelity.
NASA Astrophysics Data System (ADS)
Song, Huixu; Shi, Zhaoyao; Chen, Hongfang; Sun, Yanqiang
2018-01-01
This paper presents a novel experimental approach and a simple model for verifying that spherical mirror of laser tracking system could lessen the effect of rotation errors of gimbal mount axes based on relative motion thinking. Enough material and evidence are provided to support that this simple model could replace complex optical system in laser tracking system. This experimental approach and model interchange the kinematic relationship between spherical mirror and gimbal mount axes in laser tracking system. Being fixed stably, gimbal mount axes' rotation error motions are replaced by spatial micro-displacements of spherical mirror. These motions are simulated by driving spherical mirror along the optical axis and vertical direction with the use of precision positioning platform. The effect on the laser ranging measurement accuracy of displacement caused by the rotation errors of gimbal mount axes could be recorded according to the outcome of laser interferometer. The experimental results show that laser ranging measurement error caused by the rotation errors is less than 0.1 μm if radial error motion and axial error motion are under 10 μm. The method based on relative motion thinking not only simplifies the experimental procedure but also achieves that spherical mirror owns the ability to reduce the effect of rotation errors of gimbal mount axes in laser tracking system.
Experimental QR code optical encryption: noise-free data recovering.
Barrera, John Fredy; Mira-Agudelo, Alejandro; Torroba, Roberto
2014-05-15
We report, to our knowledge for the first time, the experimental implementation of a quick response (QR) code as a "container" in an optical encryption system. A joint transform correlator architecture in an interferometric configuration is chosen as the experimental scheme. As the implementation is not possible in a single step, a multiplexing procedure to encrypt the QR code of the original information is applied. Once the QR code is correctly decrypted, the speckle noise present in the recovered QR code is eliminated by a simple digital procedure. Finally, the original information is retrieved completely free of any kind of degradation after reading the QR code. Additionally, we propose and implement a new protocol in which the reception of the encrypted QR code and its decryption, the digital block processing, and the reading of the decrypted QR code are performed employing only one device (smartphone, tablet, or computer). The overall method probes to produce an outcome far more attractive to make the adoption of the technique a plausible option. Experimental results are presented to demonstrate the practicality of the proposed security system.
Hernandez, Purnima; Ikkanda, Zachary
2011-03-01
There are a limited number of studies addressing behavior management techniques and procedural modifications that dentists can use to treat people with an autism spectrum disorder (ASD). The authors conducted a search of the dental and behavioral analytic literature to identify management techniques that address problem behaviors exhibited by children with ASDs in dental and other health-related environments. Applied behavior analysis (ABA) is a science in which procedures are based on the principles of behavior through systematic experimentation. Clinicians have used ABA procedures successfully to modify socially significant behaviors of people with ASD. Basic behavior management techniques currently used in dentistry may not encourage people with cognitive and behavioral disabilities, such as ASD, to tolerate simple in-office dental procedures consistently. Instead, dental care providers often are required to use advanced behavior management techniques to complete simple in-office procedures such as prophylaxis, sealant placement and obtaining radiographs. ABA procedures can be integrated in the dental environment to manage problem behaviors often exhibited by children with an ASD. The authors found no evidence-based procedural modifications that address the behavioral characteristics and problematic behaviors of children with an ASD in a dental environment. Further research in this area should be conducted. Knowledge and in-depth understanding of behavioral principles is essential when a dentist is concerned with modifying behaviors. Using ABA procedures can help dentists manage problem behaviors effectively and systematically when performing routine dental treatment. Being knowledgeable about each patient's behavioral characteristics and the parents' level of involvement is important in the successful integration of the procedures and reduction of in-office time.
Structural Counterfactuals: A Brief Introduction
2013-06-01
relationships in the world. The procedure can be viewed as a concrete implementation of Ramsey’s idea ( Ramsey , 1929), according 1 Forthcoming, Cognitive...as the basis for causal discovery algorithms (Pearl & Verma, 1991; Spirtes, Glymour, & Scheines, 1993) as well as deciding identification and testing ...x′). This fraction cannot be assessed in experimental study, for the simple reason that we cannot re- test patients twice, with and without treatment
Liu, Chen-Jiang; Wang, Ji-De
2009-02-13
A simple, efficient procedure for the one-pot Biginelli condensation reaction of aldehydes, beta-ketoesters and urea or thiourea employing copper(II) sulfamate as a novel catalyst is described. Compared to the classical Biginelli reaction conditions, the present method has the advantages of good yields, short reaction times and experimental simplicity.
ERIC Educational Resources Information Center
Johnson, Eric R.
1988-01-01
Describes a laboratory experiment that measures the amount of ascorbic acid destroyed by food preparation methods (boiling and steaming). Points out that aqueous extracts of cooked green pepper samples can be analyzed for ascorbic acid by a relatively simple redox titration. Lists experimental procedure for four methods of preparation. (MVL)
Customized data container for improved performance in optical cryptosystems
NASA Astrophysics Data System (ADS)
Vélez Zea, Alejandro; Fredy Barrera, John; Torroba, Roberto
2016-12-01
Coherent optical encryption procedures introduce speckle noise to the output, limiting many practical applications. Until now the only method available to avoid this noise is to codify the information to be processed into a container that is encrypted instead of the original data. Although the decrypted container presents the noise due to the optical processing, their features remain recognizable enough to allow decoding, bringing the original information free of any kind of degradation. The first adopted containers were the quick response (QR) codes. However, the limitations of optical encryption procedures and the features of QR codes imply that in practice only simple codes containing small amounts of data can be processed without large experimental requirements. In order to overcome this problem, we introduce the first tailor made container to be processed in optical cryptosystems, ensuring larger noise tolerance and the ability to process more information with less experimental requirements. We present both simulations and experimental results to demonstrate the advantages of our proposal.
Passive hand movements disrupt adults' counting strategies.
Imbo, Ineke; Vandierendonck, André; Fias, Wim
2011-01-01
In the present study, we experimentally tested the role of hand motor circuits in simple-arithmetic strategies. Educated adults solved simple additions (e.g., 8 + 3) or simple subtractions (e.g., 11 - 3) while they were required to retrieve the answer from long-term memory (e.g., knowing that 8 + 3 = 11), to transform the problem by making an intermediate step (e.g., 8 + 3 = 8 + 2 + 1 = 10 + 1 = 11) or to count one-by-one (e.g., 8 + 3 = 8…9…10…11). During the process of solving the arithmetic problems, the experimenter did or did not move the participants' hand on a four-point matrix. The results show that passive hand movements disrupted the counting strategy while leaving the other strategies unaffected. This pattern of results is in agreement with a procedural account, showing that the involvement of hand motor circuits in adults' mathematical abilities is reminiscent of finger counting during childhood.
A Simple Numerical Procedure for the Simulation of "Lifelike" Linear-Sweep Voltammograms
NASA Astrophysics Data System (ADS)
Bozzini, Benedetto P.
2000-01-01
Practical linear-sweep voltammograms seldom resemble the theoretical ones shown in textbooks. This is because several phenomena (activation, mass transport, ohmic resistance) control the kinetics over different potential ranges scanned during the potential sweep. These effects are generally treated separately in the didactic literature, yet they have never been "assembled" in a way that allows the educational use of real experiments. This makes linear-sweep voltammetric experiments almost unusable in the teaching of physical chemistry. A simple approach to the classroom description of "lifelike" experimental results is proposed in this paper. Analytical expressions of linear sweep voltammograms are provided. The actual numerical evaluations can be carried out with a pocket calculator. Two typical examples are executed and comparison with experimental data is described. This approach to teaching electrode kinetics has proved an effective tool to provide students with an insight into the effects of electrochemical parameters and operating conditions.
Simulations of multi-contrast x-ray imaging using near-field speckles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zdora, Marie-Christine; Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom and Department of Physics & Astronomy, University College London, London, WC1E 6BT; Thibault, Pierre
2016-01-28
X-ray dark-field and phase-contrast imaging using near-field speckles is a novel technique that overcomes limitations inherent in conventional absorption x-ray imaging, i.e. poor contrast for features with similar density. Speckle-based imaging yields a wealth of information with a simple setup tolerant to polychromatic and divergent beams, and simple data acquisition and analysis procedures. Here, we present a simulation software used to model the image formation with the speckle-based technique, and we compare simulated results on a phantom sample with experimental synchrotron data. Thorough simulation of a speckle-based imaging experiment will help for better understanding and optimising the technique itself.
Control of H2S emissions using an ozone oxidation process: Preliminary results
NASA Technical Reports Server (NTRS)
Defaveri, D.; Ferrando, B.; Ferraiolo, G.
1986-01-01
The problem of eliminating industrial emission odors does not have a simple solution, and consequently has not been researched extensively. Therefore, an experimental research program regarding oxidation of H2S through ozone was undertaken to verify the applicable limits of the procedure and, in addition, was designed to supply a useful analytical means of rationalizing the design of reactors employed in the sector.
Márquez-Islas, Roberto; Sánchez-Pérez, Celia; García-Valenzuela, Augusto
2014-02-01
We describe a method for obtaining the refractive index (RI), size, and concentration of nonabsorbing nanoparticles in suspension from relatively simple optical measurements. The method requires measuring the complex effective RI of two dilute suspensions of the particles in liquids of different refractive indices. We describe the theoretical basis of the proposed method and provide experimental results validating the procedure.
The effects of relaxation breathing on procedural pain and anxiety during burn care.
Park, Eunok; Oh, Hyunjin; Kim, Taeim
2013-09-01
Burn patients experience high levels of pain and anxiety during dressing changes. Relaxation breathing is a simple behavioral intervention to manage pain and anxiety. However, the information about the effects of relaxation breathing on pain and anxiety levels for burn patients during dressing changes is limited. This study followed a quasi-experimental, pretest-posttest comparison group design without random assignment to groups. A total of 64 burn patients from Daejeon, South Korea were recruited by a convenience sequential sampling approach. With institutional approval and written consent, the experimental group practiced relaxation breathing during dressing change procedures. Data were collected from June to September 2011 using a VAS for pain and a VAS-A for anxiety. The homogeneity test was used to detect any significant group differences in the demographic data and pretest measures. The pain scores significantly differed between the 2 groups after intervention (RB group vs. control group, P=.01) and over time (pretest vs. posttest, P=.001). The anxiety scores significantly differed between the 2 groups (P=.01) and over time (P=.02). Relaxation breathing is a simple and inexpensive technique nurses can use to help burn patients manage pain and anxiety during dressing changes. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
NASA Technical Reports Server (NTRS)
Nielsen, Jack N; Kaattari, George E; Drake, William C
1952-01-01
A simple method is presented for estimating lift, pitching-moment, and hinge-moment characteristics of all-movable wings in the presence of a body as well as the characteristics of wing-body combinations employing such wings. In general, good agreement between the method and experiment was obtained for the lift and pitching moment of the entire wing-body combination and for the lift of the wing in the presence of the body. The method is valid for moderate angles of attack, wing deflection angles, and width of gap between wing and body. The method of estimating hinge moment was not considered sufficiently accurate for triangular all-movable wings. An alternate procedure is proposed based on the experimental moment characteristics of the wing alone. Further theoretical and experimental work is required to substantiate fully the proposed procedure.
Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.
Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld
2005-03-01
Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.
Acylation of Chiral Alcohols: A Simple Procedure for Chiral GC Analysis.
Oromí-Farrús, Mireia; Torres, Mercè; Canela, Ramon
2012-01-01
The use of iodine as a catalyst and either acetic or trifluoroacetic acid as a derivatizing reagent for determining the enantiomeric composition of acyclic and cyclic aliphatic chiral alcohols was investigated. Optimal conditions were selected according to the molar ratio of alcohol to acid, the reaction time, and the reaction temperature. Afterwards, chiral stability of chiral carbons was studied. Although no isomerization was observed when acetic acid was used, partial isomerization was detected with the trifluoroacetic acid. A series of chiral alcohols of a widely varying structural type were then derivatized with acetic acid using the optimal conditions. The resolution of the enantiomeric esters and the free chiral alcohols was measured using a capillary gas chromatograph equipped with a CP Chirasil-DEX CB column. The best resolutions were obtained with 2-pentyl acetates (α = 3.00) and 2-hexyl acetates (α = 1.95). This method provides a very simple and efficient experimental workup procedure for analyzing chiral alcohols by chiral-phase GC.
Performance Enhancement of a High Speed Jet Impingement System for Nonvolatile Residue Removal
NASA Technical Reports Server (NTRS)
Klausner, James F.; Mei, Renwei; Near, Steve; Stith, Rex
1996-01-01
A high speed jet impingement cleaning facility has been developed to study the effectiveness of the nonvolatile residue removal. The facility includes a high pressure air compressor which charges the k-bottles to supply high pressure air, an air heating section to vary the temperature of the high pressure air, an air-water mixing chamber to meter the water flow and generate small size droplets, and a converging- diverging nozzle to deliver the supersonic air-droplet mixture flow to the cleaning surface. To reliably quantify the cleanliness of the surface, a simple procedure for measurement and calibration is developed to relate the amount of the residue on the surface to the relative change in the reflectivity between a clean surface and the greased surface. This calibration procedure is economical, simple, reliable, and robust. a theoretical framework is developed to provide qualitative guidance for the design of the test and interpretation of the experimental results. The result documented in this report support the theoretical considerations.
Mayer, Paul M; Martineau, Eric
2011-03-21
The gas-phase binding of small molecules to the Amyloid β-40 peptide generated by electrospray ionization has been explored with collision-induced dissociation mass spectrometry and kinetic rate theory. This study discusses a simple procedure used to theoretically model the experimental breakdown diagrams for the Aβ-40 peptide complexed with a series of aminosulfonate small molecules, namely homotaurine, 3-cyclohexylamino-2-hydroxy-1-propanesulfonic acid (CAPSO), 3-(1,3,4,9-tetrahydro-2H-β-carbolin-2-yl)propane-1-sulfonic acid, 3-(1,3,4,9-tetrahydro-2H-β-carbolin-2-yl)butane-1-sulfonic acid, and 3-(cyclohexylamino)propane-1-sulfonic acid. An alternative procedure employing an extrapolation procedure for k(E) is also discussed.
Boundary condition computational procedures for inviscid, supersonic steady flow field calculations
NASA Technical Reports Server (NTRS)
Abbett, M. J.
1971-01-01
Results are given of a comparative study of numerical procedures for computing solid wall boundary points in supersonic inviscid flow calculatons. Twenty five different calculation procedures were tested on two sample problems: a simple expansion wave and a simple compression (two-dimensional steady flow). A simple calculation procedure was developed. The merits and shortcomings of the various procedures are discussed, along with complications for three-dimensional and time-dependent flows.
Guerra, J G; Rubiano, J G; Winter, G; Guerra, A G; Alonso, H; Arnedo, M A; Tejera, A; Gil, J M; Rodríguez, R; Martel, P; Bolivar, J P
2015-11-01
The determination in a sample of the activity concentration of a specific radionuclide by gamma spectrometry needs to know the full energy peak efficiency (FEPE) for the energy of interest. The difficulties related to the experimental calibration make it advisable to have alternative methods for FEPE determination, such as the simulation of the transport of photons in the crystal by the Monte Carlo method, which requires an accurate knowledge of the characteristics and geometry of the detector. The characterization process is mainly carried out by Canberra Industries Inc. using proprietary techniques and methodologies developed by that company. It is a costly procedure (due to shipping and to the cost of the process itself) and for some research laboratories an alternative in situ procedure can be very useful. The main goal of this paper is to find an alternative to this costly characterization process, by establishing a method for optimizing the parameters of characterizing the detector, through a computational procedure which could be reproduced at a standard research lab. This method consists in the determination of the detector geometric parameters by using Monte Carlo simulation in parallel with an optimization process, based on evolutionary algorithms, starting from a set of reference FEPEs determined experimentally or computationally. The proposed method has proven to be effective and simple to implement. It provides a set of characterization parameters which it has been successfully validated for different source-detector geometries, and also for a wide range of environmental samples and certified materials. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seapan, M.; Crynes, B.L.; Dale, S.
The objectives of this study were to analyze alternate crudes kinetic hydrotreatment data in the literature, develop a mathematical model for interpretation of these data, develop an experimental procedure and apparatus to collect accurate kinetic data, and finally, to combine the model and experimental data to develop a general model which, with a few experimental parameters, could be used in design of future hydrotreatment processes. These objectives were to cover a four year program (1980 to 1984) and were subjective to sufficient funding. Only partial funding has been available thus far to cover activities for two years. A hydrotreatment datamore » base is developed which contains over 2000 citations, stored in a microcomputer. About 50% of these are reviewed, classified and can be identified by feedstock, catalyst, reactor type and other process characteristics. Tests of published hydrodesulfurization data indicate the problems with simple n-th order, global kinetic models, and point to the value of developing intrinsic reaction kinetic models to describe the reaction processes. A Langmuir-Hinshelwood kinetic model coupled with a plug flow reactor design equation has been developed and used for published data evaluation. An experimental system and procedure have been designed and constructed, which can be used for kinetic studies. 30 references, 4 tables.« less
Computation of the dipole moments of proteins.
Antosiewicz, J
1995-10-01
A simple and computationally feasible procedure for the calculation of net charges and dipole moments of proteins at arbitrary pH and salt conditions is described. The method is intended to provide data that may be compared to the results of transient electric dichroism experiments on protein solutions. The procedure consists of three major steps: (i) calculation of self energies and interaction energies for ionizable groups in the protein by using the finite-difference Poisson-Boltzmann method, (ii) determination of the position of the center of diffusion (to which the calculated dipole moment refers) and the extinction coefficient tensor for the protein, and (iii) generation of the equilibrium distribution of protonation states of the protein by a Monte Carlo procedure, from which mean and root-mean-square dipole moments and optical anisotropies are calculated. The procedure is applied to 12 proteins. It is shown that it gives hydrodynamic and electrical parameters for proteins in good agreement with experimental data.
NASA Astrophysics Data System (ADS)
Royston, Thomas J.; Zhang, Xiangling; Mansy, Hussein A.; Sandler, Richard H.
2002-05-01
Experimental studies have shown that a pneumothorax (collapsed lung) substantially alters the propagation of sound introduced at the mouth of an intubated subject and measured at the chest surface. Thus, it is hypothesized that an inexpensive diagnostic procedure could be developed for detection of a pneumothorax based on a simple acoustic test. In the present study, theoretical models of sound transmission through the pulmonary system and chest region are reviewed in the context of their ability to predict acoustic changes caused by a pneumothorax, as well as other pathologic conditions. Such models could aid in parametric design studies to develop acoustic means of diagnosing pneumothorax and other lung pathologies. Extensions of previously developed simple models of the authors are presented that are in more quantitative agreement with experimental results and that simulate both transmission from the bronchial airways to the chest wall, as well as reflection in the bronchial airways. [Research supported by NIH NCRR Grant No. 14250 and NIH NHLBI Grant No. 61108.
Simple Organics and Biomonomers Identified in HCN Polymers: An Overview
Ruiz-Bermejo, Marta; Zorzano, María-Paz; Osuna-Esteban, Susana
2013-01-01
Hydrogen cyanide (HCN) is a ubiquitous molecule in the Universe. It is a compound that is easily produced in significant yields in prebiotic simulation experiments using a reducing atmosphere. HCN can spontaneously polymerise under a wide set of experimental conditions. It has even been proposed that HCN polymers could be present in objects such as asteroids, moons, planets and, in particular, comets. Moreover, it has been suggested that these polymers could play an important role in the origin of life. In this review, the simple organics and biomonomers that have been detected in HCN polymers, the analytical techniques and procedures that have been used to detect and characterise these molecules and an exhaustive classification of the experimental/environmental conditions that favour the formation of HCN polymers are summarised. Nucleobases, amino acids, carboxylic acids, cofactor derivatives and other compounds have been identified in HCN polymers. The great molecular diversity found in HCN polymers encourages their placement at the central core of a plausible protobiological system. PMID:25369814
Novel Fabry-Perot fiber optic sensor with multiple applications
NASA Astrophysics Data System (ADS)
Chen, Xiaopei; Shen, Fabin; Wang, Anbo; Wang, Zhuang; Zhang, Yan
2004-12-01
A novel Intrinsic Fabry-Perot fiber-optic sensor is presented in this paper. The sensors were made through two simple steps: wet chemical etch and fusion splice. Micro air-gaps were generated inside the fibers and functioned as reflective mirrors. This procedure not only provides a simple and cost effective technology for fabricating intrinsic Fabry-Perot Interferometric (IFPI) fiber sensors, but also provides two possible IFPI structures. Both of the fiber cavity between the air-gaps or the air-gap and cleaved fiber end can be used as sensing elements. With these two structures, this sensor can be used to measure the temperature, strain, pressure, refractive index of chemicals and the thin film thickness by itself. Multi-point measurements can also be achieved by multiplexing. Furthermore, it also can be multiplexed with other sensors such as Long Period Gratings (LPG) to provide compensations for other perturbation sensing. Theoretical and experimental studies of two sensor structures are described. Experimental results show that high resolution and high sensitivity can be obtained with appropriate signal processing.
Modern projection of the old electroscope for nuclear radiation quantitative work and demonstrations
NASA Astrophysics Data System (ADS)
Oliveira Bastos, Rodrigo; Baltokoski Boch, Layara
2017-11-01
Although quantitative measurements in radioactivity teaching and research are only believed to be possible with high technology, early work in this area was fully accomplished with very simple apparatus such as zinc sulphide screens and electroscopes. This article presents an experimental practice using the electroscope, which is a very simple apparatus that has been widely used for educational purposes, although generally for qualitative work. The main objective is to show the possibility of measuring radioactivity not only in qualitative demonstrations, but also in quantitative experimental practices. The experimental set-up is a low-cost ion chamber connected to an electroscope in a configuration that is very similar to that used by Marie and Pierre Currie, Rutherford, Geiger, Pacini, Hess and other great researchers from the time of the big discoveries in nuclear and high-energy particle physics. An electroscope leaf is filmed and projected, permitting the collection of quantitative data for the measurement of the 220Rn half-life, collected from the emanation of the lantern mantles. The article presents the experimental procedures and the expected results, indicating that the experiment may provide support for nuclear physics classes. These practices could spread widely to either university or school didactic laboratories, and the apparatus has the potential to allow the development of new teaching activity for nuclear physics.
The Kelvin water-drop experiment
NASA Technical Reports Server (NTRS)
Shull, Robert D.
1990-01-01
This experiment was originally designed and performed by Lord Kelvin (William Thomson) in the late 1800's to demonstrate the creation of an electric potential simply by means of dividing up a body of flowing water. The objective is to demonstrate the power of electrical forces in a material as common as water and to help teach the student that even simple, well understood phenomena sometimes present unexpected results that, at first thought, defeat explanation. The experimental equipment and procedure are explained.
A versatile calibration procedure for portable coded aperture gamma cameras and RGB-D sensors
NASA Astrophysics Data System (ADS)
Paradiso, V.; Crivellaro, A.; Amgarou, K.; de Lanaute, N. Blanc; Fua, P.; Liénard, E.
2018-04-01
The present paper proposes a versatile procedure for the geometrical calibration of coded aperture gamma cameras and RGB-D depth sensors, using only one radioactive point source and a simple experimental set-up. Calibration data is then used for accurately aligning radiation images retrieved by means of the γ-camera with the respective depth images computed with the RGB-D sensor. The system resulting from such a combination is thus able to retrieve, automatically, the distance of radioactive hotspots by means of pixel-wise mapping between gamma and depth images. This procedure is of great interest for a wide number of applications, ranging from precise automatic estimation of the shape and distance of radioactive objects to Augmented Reality systems. Incidentally, the corresponding results validated the choice of a perspective design model for a coded aperture γ-camera.
Object permanence in orangutans (Pongo pygmaeus) and squirrel monkeys (Saimiri sciureus).
de Blois, S T; Novak, M A; Bond, M
1998-06-01
The authors tested orangutans (Pongo pygmaeus) and squirrel monkeys (Saimiri sciureus) on object permanence tasks. In Experiment 1, orangutans solved all visible displacements and most invisible displacements except those involving movements into 2 boxes successively. In Experiment 2, performance of orangutans on double invisible displacements and control displacements (assessing simple strategies) was compared. Orangutans did not use the simple strategy of selecting the box visited last by the experimenter. Instead, poorer performance on double invisible displacements may have been related to increased memory requirements. In Experiment 3, squirrel monkeys were tested using the procedure of Experiment 1. Squirrel monkeys solved visible but did not comprehend invisible displacements. Results suggest that orangutans but not squirrel monkeys possess Stage 6 object permanence capabilities.
NASA Astrophysics Data System (ADS)
Kumavat, Hemraj Ramdas
2016-09-01
The compressive stress-strain behavior and mechanical properties of clay brick masonry and its constituents clay bricks and mortar, have been studied by several laboratory tests. Using linear regression analysis, a analytical model has been proposed for obtaining the stress-strain curves for masonry that can be used in the analysis and design procedures. The model requires only the compressive strengths of bricks and mortar as input data, which can be easily obtained experimentally. Development of analytical model from the obtained experimental results of Young's modulus and compressive strength. Simple relationships have been identified for obtaining the modulus of elasticity of bricks, mortar, and masonry from their corresponding compressive strengths. It was observed that the proposed analytical model clearly demonstrates a reasonably good prediction of the stress-strain curves when compared with the experimental curves.
Experimental study and simulation of 63Zn production via proton induce reaction.
Rostampour, Malihe; Sadeghi, Mahdi; Aboudzadeh, Mohammadreza; Hamidi, Saeid; Soltani, Naser; Novin, Fatemeh Bolouri; Rahiminejad, Ali; Rajabifar, Saeid
2018-06-01
The 63 Zn was produced by16.8 MeV proton irradiation of natural copper. Thick target yield for 63 Zn in the energy range of 16.8 →12.2 MeV was 2.47 ± 0.12 GBq/μA.h. Reasonable agreement between achieved experimental data and theoretical value of thick target yield for 63 Zn was observed. A simple separation procedure of 63 Zn from copper target was developed using cation exchange chromatography. About 88 ± 5% of the loaded activity was recovered. The performance of FLUKA to reproduce experimental data of thick target yield of 63 Zn is validated. The achieved results from this code were compared with the corresponding experimental data. This comparison demonstrated that FLUKA provides a suitable tool for the simulation of radionuclide production using proton irradiation. Copyright © 2018 Elsevier Ltd. All rights reserved.
Imaging the wave functions of adsorbed molecules
Lüftner, Daniel; Ules, Thomas; Reinisch, Eva Maria; Koller, Georg; Soubatch, Serguei; Tautz, F. Stefan; Ramsey, Michael G.; Puschnig, Peter
2014-01-01
The basis for a quantum-mechanical description of matter is electron wave functions. For atoms and molecules, their spatial distributions and phases are known as orbitals. Although orbitals are very powerful concepts, experimentally only the electron densities and -energy levels are directly observable. Regardless whether orbitals are observed in real space with scanning probe experiments, or in reciprocal space by photoemission, the phase information of the orbital is lost. Here, we show that the experimental momentum maps of angle-resolved photoemission from molecular orbitals can be transformed to real-space orbitals via an iterative procedure which also retrieves the lost phase information. This is demonstrated with images obtained of a number of orbitals of the molecules pentacene (C22H14) and perylene-3,4,9,10-tetracarboxylic dianhydride (C24H8O6), adsorbed on silver, which are in excellent agreement with ab initio calculations. The procedure requires no a priori knowledge of the orbitals and is shown to be simple and robust. PMID:24344291
Prediction of plastic instabilities under thermo-mechanical loadings in tension and simple shear
NASA Astrophysics Data System (ADS)
Manach, P. Y.; Mansouri, L. F.; Thuillier, S.
2016-08-01
Plastic instabilities like Portevin-Le Châtelier were quite thoroughly investigated experimentally in tension, under a large range of strain rates and temperatures. Such instabilities are characterized both by a jerky flow and a localization of the strain in bands. Similar phenomena were also recorded for example in simple shear [1]. Modelling of this phenomenon is mainly performed at room temperature, taking into account the strain rate sensitivity, though an extension of the classical Estrin-Kubin-McCormick was proposed in the literature, by making some of the material parameters dependent on temperature. A similar approach is considered in this study, furthermore extended for anisotropic plasticity with Hill's 1948 yield criterion. Material parameters are identified at 4 different temperatures, ranging from room temperature up to 250°C. The identification procedure is split in 3 steps, related to the elasticity, the average stress level and the magnitude of the stress drops. The anisotropy is considered constant in this temperature range, as evidenced by experimental results [2]. The model is then used to investigate the temperature dependence of the critical strain, as well as its capability to represent the propagation of the bands. Numerical predictions of the instabilities in tension and simple shear at room temperature and up to 250°C are compared with experimental results [3]. In the case of simple shear, a monotonic loading followed by unloading and reloading in the reverse direction (“Bauschinger-type” test) is also considered, showing that (i) kinematic hardening should be taken into account to fully describe the transition at re-yielding (ii) the modelling of the critical strain has to be improved.
Measuring complete quantum states with a single observable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng Xinhua; Suter, Dieter; Du Jiangfeng
2007-10-15
Experimental determination of an unknown quantum state usually requires several incompatible measurements. However, it is also possible to determine the full quantum state from a single, repeated measurement. For this purpose, the quantum system whose state is to be determined is first coupled to a second quantum system (the 'assistant') in such a way that part of the information in the quantum state is transferred to the assistant. The actual measurement is then performed on the enlarged system including the original system and the assistant. We discuss in detail the requirements of this procedure and experimentally implement it on amore » simple quantum system consisting of nuclear spins.« less
NASA Astrophysics Data System (ADS)
Mahaut, Fabien; Bertrand, François; Coussot, Philippe; Chateau, Xavier; Ovarlez, Guillaume
2008-07-01
We study experimentally and theoretically the behavior of suspensions of noncolloidal particles in yield stress fluids. We develop procedures and materials that allow focusing on the purely mechanical contribution of the particles to the yield stress fiuid behavior, allowing relating the macroscopic properties of these suspensions to the mechanical properties of the yield stress fluid and the particle volume fraction. We find that the elastic modulus/concentration relationship follows a Krieger-Dougherty law, and show that the yield stress/concentration relationship is related to the elastic modulus/concentration relationship through a very simple law, in agreement with a micromechanical analysis. We finally present evidence for shear-induced migration in the flows of these suspensions.
NASA Astrophysics Data System (ADS)
Brunger, M. J.; Thorn, P. A.; Campbell, L.; Kato, H.; Kawahara, H.; Hoshino, M.; Tanaka, H.; Kim, Y.-K.
2008-05-01
We consider the efficacy of the BEf-scaling approach, in calculating reliable integral cross sections for electron impact excitation of dipole-allowed electronic states in molecules. We will demonstrate, using specific examples in H2, CO and H2O, that this relatively simple procedure can generate quite accurate integral cross sections which compare well with available experimental data. Finally, we will briefly consider the ramifications of this to atmospheric and other types of modelling studies.
Novel zero voltage transition pulse width modulation flyback converter
NASA Astrophysics Data System (ADS)
Adib, Ehsan; Farzanehfard, Hosein
2010-09-01
In this article, a new zero voltage (ZV) transition flyback converter is introduced which uses a simple auxiliary circuit. In this converter, ZV switching condition is achieved for the converter switch while zero current switching condition is attained for the auxiliary switch. There is no additional voltage and current stress on the main switch. Main diode, auxiliary circuit voltage and current ratings are low. The proposed converter is analysed and design procedure is discussed. The presented experimental results of a prototype converter justify the theoretical analysis.
Test equality in binary data for a 4 × 4 crossover trial under a Latin-square design.
Lui, Kung-Jong; Chang, Kuang-Chao
2016-10-15
When there are four or more treatments under comparison, the use of a crossover design with a complete set of treatment-receipt sequences in binary data is of limited use because of too many treatment-receipt sequences. Thus, we may consider use of a 4 × 4 Latin square to reduce the number of treatment-receipt sequences when comparing three experimental treatments with a control treatment. Under a distribution-free random effects logistic regression model, we develop simple procedures for testing non-equality between any of the three experimental treatments and the control treatment in a crossover trial with dichotomous responses. We further derive interval estimators in closed forms for the relative effect between treatments. To evaluate the performance of these test procedures and interval estimators, we employ Monte Carlo simulation. We use the data taken from a crossover trial using a 4 × 4 Latin-square design for studying four-treatments to illustrate the use of test procedures and interval estimators developed here. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Flowers for Algernon: The ethics of human experimentation on the intellectually disabled.
Ghoshal, Nishan; Wilkinson, Paul O
2017-09-01
Flowers for Algernon is a novel written in 1966 by Daniel Keyes. Since its publication, it has received significant critical acclaim, earning a Nebula science-fiction award, and was also adapted into a feature film. Set in the 1960s, the novel follows the story of Charlie Gordon, an intellectually disabled man who lives a simple but happy life working a cleaning job at a local bakery. Charlie's life, however, faces an abrupt change when he is offered the opportunity to participate in a novel surgical procedure to improve his intellect. Although he doesn't fully understand the risks of the operation, consent is provided on his behalf by his estranged sister and Charlie undergoes the experiment. The experiment is a success and Charlie develops intellectually at an alarming pace, soon surpassing the experimenters themselves. The rest of the book follows the, not all positive, changes that this intellect brings to Charlie's life. The novel is set in a time when American scientific experimentation could often occur without fully informed consent. This article explores the ethical side of such experiments like the one performed on Charlie, namely if it is morally right to perform a potentially dangerous experimental procedure on someone who doesn't fully understand the risks, even if it will potentially help them.
Raza, Asad; Zia-Ul-Haq, Muhammad
2011-01-01
Two simple, fast, and accurate spectrophotometric methods for the determination of alendronate sodium are described. The methods are based on charge-transfer complex formation of the drug with two π-electron acceptors 7,7,7,8-tetracyanoquinodimethane (TCNQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in acetonitrile and methanol medium. The methods are followed spectrophotometrically by measuring the maximum absorbance at 840 nm and 465 nm, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 2-10 μg mL(-1) and 2-12 μg mL(-1), respectively. The optimal reactions conditions values such as the reagent concentration, heating time, and stability of reaction product were determined. No significant difference was obtained between the results of newly proposed methods and the B.P. Titrimetric procedures. The charge transfer approach using TCNQ and DDQ procedures described in this paper is simple, fast, accurate, precise, and extraction-free.
Raza, Asad; Zia-ul-Haq, Muhammad
2011-01-01
Two simple, fast, and accurate spectrophotometric methods for the determination of alendronate sodium are described. The methods are based on charge-transfer complex formation of the drug with two π-electron acceptors 7,7,7,8-tetracyanoquinodimethane (TCNQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in acetonitrile and methanol medium. The methods are followed spectrophotometrically by measuring the maximum absorbance at 840 nm and 465 nm, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 2–10 μg mL−1 and 2–12 μg mL−1, respectively. The optimal reactions conditions values such as the reagent concentration, heating time, and stability of reaction product were determined. No significant difference was obtained between the results of newly proposed methods and the B.P. Titrimetric procedures. The charge transfer approach using TCNQ and DDQ procedures described in this paper is simple, fast, accurate, precise, and extraction-free. PMID:21760789
Model Checking Satellite Operational Procedures
NASA Astrophysics Data System (ADS)
Cavaliere, Federico; Mari, Federico; Melatti, Igor; Minei, Giovanni; Salvo, Ivano; Tronci, Enrico; Verzino, Giovanni; Yushtein, Yuri
2011-08-01
We present a model checking approach for the automatic verification of satellite operational procedures (OPs). Building a model for a complex system as a satellite is a hard task. We overcome this obstruction by using a suitable simulator (SIMSAT) for the satellite. Our approach aims at improving OP quality assurance by automatic exhaustive exploration of all possible simulation scenarios. Moreover, our solution decreases OP verification costs by using a model checker (CMurphi) to automatically drive the simulator. We model OPs as user-executed programs observing the simulator telemetries and sending telecommands to the simulator. In order to assess feasibility of our approach we present experimental results on a simple meaningful scenario. Our results show that we can save up to 90% of verification time.
Detection of hepatocarcinoma in rats by integration of the fluorescence spectrum: Experimental model
NASA Astrophysics Data System (ADS)
Marcassa, J. C.; Ferreira, J.; Zucoloto, S.; Castro E Silva, O., Jr.; Marcassa, L. G.; Bagnato, V. S.
2006-05-01
The incorporation of spectroscopic techniques into diagnostic procedures may greatly improve the chances for precise diagnostics. One promising technique is fluorescence spectroscopy, which has recently been used to detect many different types of diseases. In this work, we use laser-induced tissue fluorescence to detect hepatocarcinoma in rats using excitation light at wavelengths of 443 and 532 nm. Hepatocarcinoma was induced chemically in Wistar rats. The collected fluorescence spectrum ranges from the excitation wavelength up to 850 nm. A mathematical procedure carried out on the spectrum determines a figure of merit value, which allows the detection of hepatocarcinoma. The figure of merit involves a procedure which evaluates the ratio between the backscattered excitation wavelength and the broad emission fluorescence band. We demonstrate that a normalization allowed by integration of the fluorescence spectra is a simple operation that may allow the detection of hepatocarcinoma.
Kold, S; Soballe, K; Mouzin, O; Chen, Xiangmei; Toft, M; Bechtold, J
2002-01-01
We used an experimental model producing a tissue response with a sclerotic endosteal neo-cortical rim associated with implant loosening in humans: a 6 mm PMMA cylinder pistoned 500 m concentrically in a 7.5 mm hole, with polyethylene particles. At a second operation at eight weeks, the standard revision procedure removed the fibrous membrane in one knee, and the crack revision procedure was used to crack the sclerotic endosteal rim in the contralateral knee. Once stability was achieved following the revision procedures, loaded Ti plasma sprayed implants were inserted into the revision cavities of 8 dogs for an additional 4 weeks. Revision implant fixation (ultimate shear strength and energy absorption) was significantly enhanced by cracking the sclerotic endosteal rim. In conclusion, we demonstrated a simple technique of cracking the sclerotic endosteal rim as an additional method for improving revision fixation. (Hip International 2002; 2: 77-9).
A comparison of simple shear characterization methods for composite laminates
NASA Technical Reports Server (NTRS)
Yeow, Y. T.; Brinson, H. F.
1978-01-01
Various methods for the shear stress/strain characterization of composite laminates are examined and their advantages and limitations are briefly discussed. Experimental results and the necessary accompanying analysis are then presented and compared for three simple shear characterization procedures. These are the off-axis tensile test method, the (+/- 45 deg)s tensile test method and the (0/90 deg)s symmetric rail shear test method. It is shown that the first technique indicates the shear properties of the graphite/epoxy laminates investigated are fundamentally brittle in nature while the latter two methods tend to indicate that these laminates are fundamentally ductile in nature. Finally, predictions of incrementally determined tensile stress/strain curves utilizing the various different shear behaviour methods as input information are presented and discussed.
A comparison of simple shear characterization methods for composite laminates
NASA Technical Reports Server (NTRS)
Yeow, Y. T.; Brinson, H. F.
1977-01-01
Various methods for the shear stress-strain characterization of composite laminates are examined, and their advantages and limitations are briefly discussed. Experimental results and the necessary accompanying analysis are then presented and compared for three simple shear characterization procedures. These are the off-axis tensile test method, the + or - 45 degs tensile test method and the 0 deg/90 degs symmetric rail shear test method. It is shown that the first technique indicates that the shear properties of the G/E laminates investigated are fundamentally brittle in nature while the latter two methods tend to indicate that the G/E laminates are fundamentally ductile in nature. Finally, predictions of incrementally determined tensile stress-strain curves utilizing the various different shear behavior methods as input information are presented and discussed.
SERE: single-parameter quality control and sample comparison for RNA-Seq.
Schulze, Stefan K; Kanwar, Rahul; Gölzenleuchter, Meike; Therneau, Terry M; Beutler, Andreas S
2012-10-03
Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson's correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson's r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen's simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter.
SERE: Single-parameter quality control and sample comparison for RNA-Seq
2012-01-01
Background Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson’s correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Results Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson’s r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen’s simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. Conclusions SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter. PMID:23033915
NASA Technical Reports Server (NTRS)
Scott, Elaine P.
1996-01-01
A thermal stress analysis is an important aspect in the design of aerospace structures and vehicles such as the High Speed Civil Transport (HSCT) at the National Aeronautics and Space Administration Langley Research Center (NASA-LaRC). These structures are complex and are often composed of numerous components fabricated from a variety of different materials. The thermal loads on these structures induce temperature variations within the structure, which in turn result in the development of thermal stresses. Therefore, a thermal stress analysis requires knowledge of the temperature distributions within the structures which consequently necessitates the need for accurate knowledge of the thermal properties, boundary conditions and thermal interface conditions associated with the structural materials. The goal of this proposed multi-year research effort was to develop estimation methodologies for the determination of the thermal properties and interface conditions associated with aerospace vehicles. Specific objectives focused on the development and implementation of optimal experimental design strategies and methodologies for the estimation of thermal properties associated with simple composite and honeycomb structures. The strategy used in this multi-year research effort was to first develop methodologies for relatively simple systems and then systematically modify these methodologies to analyze complex structures. This can be thought of as a building block approach. This strategy was intended to promote maximum usability of the resulting estimation procedure by NASA-LARC researchers through the design of in-house experimentation procedures and through the use of an existing general purpose finite element software.
Efficacy of a Procedure-Specific Education Module on Informed Consent in Plastic Surgery.
Brandel, Michael G; Reid, Christopher M; Parmeshwar, Nisha; Dobke, Marek K; Gosman, Amanda A
2017-05-01
Truly informed consent is an elusive goal, seldom attained in medical or surgical practice. Patients often do not fully understand procedures and therapies they undergo or the associated sequelae. Historically, informed consent and patient education have been limited to physician discussions, sometimes with the addition of simple visual aids. More recently, there is a growing body of decision aids available, including interactive multimedia patient educational modules that review preoperative through postoperative care, risks, benefits, alternatives, different surgical options, as well as commonly asked questions. We hypothesized that the addition of a Web-based educational tool would positively impact attainment of informed consent and satisfaction in plastic surgery patients. We performed a prospective randomized controlled study comparing patients who presented in consultation for breast reconstruction, breast reduction, and abdominoplasty. Patients received standard patient education along with a procedure-specific (study) or general patient safety (control) Web-based educational module. Informed consent was measured using a surgical-focused, modified version of the Shared Decision-making 25 index tool. Patient demographic information as well as surrogate markers of familiarity with technology were recorded preoperatively and postoperatively. Comparisons were made between study and control groups, procedure subgroups, and preoperative and postoperative time points. Demographic factors and consent variables were compared among experimental and procedure groups. Data were collected from 65 patients preoperatively and 48 patients postoperatively. Thirty patients competed both surveys. Overall, no differences in patient characteristics or familiarity with technology were observed between experimental groups. Demographic characteristics were also similar between groups. No meaningful differences were identified in comparisons between experimental groups on either cross-sectional or longitudinal analyses. Nearly all patient responses were consistent with being well informed and satisfied with the educational process. Overall, patients undergoing plastic surgery procedures are adequately informed and have a high degree of satisfaction regarding their patient education. The addition of a Web-based informed consent tool did not make a demonstrable difference in informed consent.
Verevkin, Sergey P; Zaitsau, Dzmitry H; Emel'yanenko, Vladimir N; Yermalayeu, Andrei V; Schick, Christoph; Liu, Hongjun; Maginn, Edward J; Bulut, Safak; Krossing, Ingo; Kalb, Roland
2013-05-30
Vaporization enthalpy of an ionic liquid (IL) is a key physical property for applications of ILs as thermofluids and also is useful in developing liquid state theories and validating intermolecular potential functions used in molecular modeling of these liquids. Compilation of the data for a homologous series of 1-alkyl-3-methylimidazolium bis(trifluoromethane-sulfonyl)imide ([C(n)mim][NTf2]) ILs has revealed an embarrassing disarray of literature results. New experimental data, based on the concurring results from quartz crystal microbalance, thermogravimetric analyses, and molecular dynamics simulation have revealed a clear linear dependence of IL vaporization enthalpies on the chain length of the alkyl group on the cation. Ambiguity of the procedure for extrapolation of vaporization enthalpies to the reference temperature 298 K was found to be a major source of the discrepancies among previous data sets. Two simple methods for temperature adjustment of vaporization enthalpies have been suggested. Resulting vaporization enthalpies obey group additivity, although the values of the additivity parameters for ILs are different from those for molecular compounds.
[Experimental study on establishment of a simple model of rats crush injury-crush syndrome].
Chen, Xi; Liu, Yuehong; Xu, Wei; Qin, Tingwu; Zhao, Luping; Liu, Shuping; Zhang, Yi; Tan, Hong; Zhou, Yu
2013-01-01
To establish a repeatable, simple, and effective model of rat crush injury and crush syndrome. A total of 42 female Sprague Dawley rats (2-month-old, (CS) so as to lay a foundation for further study on CS. weighing 160-180 g) were divided randomly into the control group (n=6) and experimental group (n=36). The rats of the experimental group were used to establish the crush injury and CS model in both lower limbs by self-made crush injury mould. The survival rate and hematuria rate were observed after decompression. The biochemical indexes of blood were measured at 2, 4, 8, 12, 24, and 48 hours after decompression. The samples of muscle, kidney, and heart were harvested for morphological observation. There was no treatment in the control group, and the same tests were performed. Seven rats died and 15 rats had hematuria during compression in the experimental group. Swelling of the lower limb and muscle tissue was observed in the survival rats after reperfusion. The liver function test results showed that the levels of alanine transaminase and aspartate aminotransferase in the experimental group were significantly higher than those in the control group (P < 0.05). The renal function test results showed that blood urea nitrogen level increased significantly after 2 hours of decompression in the experimental group, showing significant difference when compared with that in the control group at 12, 24, and 48 hours after decompression (P < 0.05); the creatinine level of the experimental group was higher than that of the control group at 4, 8, 12, and 24 hours, showing significant difference at 8, 12, and 24 hours (P < 0.05). The serum K+ concentration of the experimental group was higher than that of the control group at all time, showing significant difference at the other time (P < 0.05) except at 2 hours. The creatine kinase level showed an increasing tendency in the experimental group, showing significant difference when compared with the level of the control group at 4, 8, 12, and 24 hours (P < 0.05). The histological examination of the experimental group showed that obvious edema and necrosis of the muscle were observed at different time points; glomeruli congestion and swelling, renal tubular epithelial cell degeneration, edema, necrosis, and myoglobin tube type were found in the kidneys; and myocardial structure had no obvious changes. The method of the crush injury and CS model by self-made crush injury mould is a simple and effective procedure and the experimental result is stable. It is a simple method to establish an effective model of rats crush injury and CS.
The binding domain of the HMGB1 inhibitor carbenoxolone: Theory and experiment
NASA Astrophysics Data System (ADS)
Mollica, Luca; Curioni, Alessandro; Andreoni, Wanda; Bianchi, Marco E.; Musco, Giovanna
2008-05-01
We present a combined computational and experimental study of the interaction of the Box A of the HMGB1 protein and carbenoxolone, an inhibitor of its pro-inflammatory activity. The computational approach consists of classical molecular dynamics (MD) simulations based on the GROMOS force field with quantum-refined (QRFF) atomic charges for the ligand. Experimental data consist of fluorescence intensities, chemical shift displacements, saturation transfer differences and intermolecular Nuclear Overhauser Enhancement signals. Good agreement is found between observations and the conformation of the ligand-protein complex resulting from QRFF-MD. In contrast, simple docking procedures and MD based on the unrefined force field provide models inconsistent with experiment. The ligand-protein binding is dominated by non-directional interactions.
NASA Technical Reports Server (NTRS)
Bailey, J. A.
1976-01-01
Project planning for two series of simple experiments on the effect of zero gravity on the melting and freezing of metals and nonmetals is described. The experiments will be performed in the Long Duration Exposure Facility, and their purpose will be to study: (1) the general morphology of metals and nonmetals during solidification, (2) the location of ullage space (liquid-vapor interfaces), and (3) the magnitude of surface tension driven convection during solidification of metals and nonmetals. The preliminary design of the experiments is presented. Details of the investigative approach, experimental procedure, experimental hardware, data reduction and analysis, and anticipated results are given. In addition a work plan and cost analysis are provided.
NASA Astrophysics Data System (ADS)
Witzman, S.; Shitzer, A.; Zvirin, Y.
A simple mathematical algorithm which facilitates the design of a latent heat reservoir for stabilizing the temperature of an inflight electronic device is developed, and the behavior of paraffin wax in a heat storage capacitor is experimentally studied. The results show that in the solidification stage the heat transfer coefficient h is smaller than 35 W/sq m - C and decreases with time. During the melting process, natural convection could significantly increase h on the internal side and thereby reduce the time required to melt the section compared to the conduction process alone. Values of h up to 60 W/sq m - C can be achieved. The correlation between experimental and theoretical results is good.
Sanagi, M Marsin; Nasir, Zalilah; Ling, Susie Lu; Hermawan, Dadan; Ibrahim, Wan Aini Wan; Naim, Ahmedy Abu
2010-01-01
Linearity assessment as required in method validation has always been subject to different interpretations and definitions by various guidelines and protocols. However, there are very limited applicable implementation procedures that can be followed by a laboratory chemist in assessing linearity. Thus, this work proposes a simple method for linearity assessment in method validation by a regression analysis that covers experimental design, estimation of the parameters, outlier treatment, and evaluation of the assumptions according to the International Union of Pure and Applied Chemistry guidelines. The suitability of this procedure was demonstrated by its application to an in-house validation for the determination of plasticizers in plastic food packaging by GC.
State of charge estimation in Ni-MH rechargeable batteries
NASA Astrophysics Data System (ADS)
Milocco, R. H.; Castro, B. E.
In this work we estimate the state of charge (SOC) of Ni-MH rechargeable batteries using the Kalman filter based on a simplified electrochemical model. First, we derive the complete electrochemical model of the battery which includes diffusional processes and kinetic reactions in both Ni and MH electrodes. The full model is further reduced in a cascade of two parts, a linear time invariant dynamical sub-model followed by a static nonlinearity. Both parts are identified using the current and potential measured at the terminals of the battery with a simple 1-D minimization procedure. The inverse of the static nonlinearity together with a Kalman filter provide the SOC estimation as a linear estimation problem. Experimental results with commercial batteries are provided to illustrate the estimation procedure and to show the performance.
Piérard, Gérald E.; Piérard-Franchimont, Claudine; Paquet, Philippe; Hermanns-Lê, Trinh; Delvenne, Philippe
2014-01-01
In the dermatopathology field, some simple available laboratory tests require minimum equipment for establishing a diagnosis. Among them, the cyanoacrylate skin surface stripping (CSSS), formerly named skin surface biopsy or follicular biopsy, represents a convenient low cost procedure. It is a minimally invasive method collecting a continuous sheet of stratum corneum and horny follicular casts. In the vast majority of cases, it is painless and is unassociated with adverse events. CSSS can be performed in subjects of any age. The method has a number of applications in diagnostic dermatopathology and cosmetology, as well as in experimental dermatology settings. A series of derived analytic procedures include xerosis grading, comedometry, corneofungimetry, corneodynamics of stratum corneum renewal, corneomelametry, corneosurfametry, and corneoxenometry. PMID:25177726
Caveats and considerations for performing pancreas-specific gene manipulations in the mouse.
Magnuson, M A; Burlison, J S
2007-11-01
Conditional gene targeting using the Cre/loxP strategy has proven to be very useful for studies of glucose homeostasis, tissue function and dysfunction in diabetes, and pancreas development. However, use of this strategy over the past decade has revealed a variety of experimental caveats, many of which are a direct consequence of the procedures used to generate Cre-driver lines. We discuss frequently encountered experimental artefacts, the advantages of using bacterial artificial chromosome-derived transgenes or performing a Cre knockin for improving the specificity of expression, and systems for regulating Cre activity. In addition, recent studies indicate that high amounts of Cre in the pancreatic beta-cell may cause glucose intolerance and impaired insulin secretion. However, these findings, while serving as a reminder for simple experimental controls, are unlikely to diminish utilization of this very powerful and useful technology.
James, Ella L; Bonsall, Michael B; Hoppitt, Laura; Tunbridge, Elizabeth M; Geddes, John R; Milton, Amy L; Holmes, Emily A
2015-08-01
Memory of a traumatic event becomes consolidated within hours. Intrusive memories can then flash back repeatedly into the mind's eye and cause distress. We investigated whether reconsolidation-the process during which memories become malleable when recalled-can be blocked using a cognitive task and whether such an approach can reduce these unbidden intrusions. We predicted that reconsolidation of a reactivated visual memory of experimental trauma could be disrupted by engaging in a visuospatial task that would compete for visual working memory resources. We showed that intrusive memories were virtually abolished by playing the computer game Tetris following a memory-reactivation task 24 hr after initial exposure to experimental trauma. Furthermore, both memory reactivation and playing Tetris were required to reduce subsequent intrusions (Experiment 2), consistent with reconsolidation-update mechanisms. A simple, noninvasive cognitive-task procedure administered after emotional memory has already consolidated (i.e., > 24 hours after exposure to experimental trauma) may prevent the recurrence of intrusive memories of those emotional events. © The Author(s) 2015.
James, Ella L.; Bonsall, Michael B.; Hoppitt, Laura; Tunbridge, Elizabeth M.; Geddes, John R.; Milton, Amy L.
2015-01-01
Memory of a traumatic event becomes consolidated within hours. Intrusive memories can then flash back repeatedly into the mind’s eye and cause distress. We investigated whether reconsolidation—the process during which memories become malleable when recalled—can be blocked using a cognitive task and whether such an approach can reduce these unbidden intrusions. We predicted that reconsolidation of a reactivated visual memory of experimental trauma could be disrupted by engaging in a visuospatial task that would compete for visual working memory resources. We showed that intrusive memories were virtually abolished by playing the computer game Tetris following a memory-reactivation task 24 hr after initial exposure to experimental trauma. Furthermore, both memory reactivation and playing Tetris were required to reduce subsequent intrusions (Experiment 2), consistent with reconsolidation-update mechanisms. A simple, noninvasive cognitive-task procedure administered after emotional memory has already consolidated (i.e., > 24 hours after exposure to experimental trauma) may prevent the recurrence of intrusive memories of those emotional events. PMID:26133572
Phase-unwrapping algorithm by a rounding-least-squares approach
NASA Astrophysics Data System (ADS)
Juarez-Salazar, Rigoberto; Robledo-Sanchez, Carlos; Guerrero-Sanchez, Fermin
2014-02-01
A simple and efficient phase-unwrapping algorithm based on a rounding procedure and a global least-squares minimization is proposed. Instead of processing the gradient of the wrapped phase, this algorithm operates over the gradient of the phase jumps by a robust and noniterative scheme. Thus, the residue-spreading and over-smoothing effects are reduced. The algorithm's performance is compared with four well-known phase-unwrapping methods: minimum cost network flow (MCNF), fast Fourier transform (FFT), quality-guided, and branch-cut. A computer simulation and experimental results show that the proposed algorithm reaches a high-accuracy level than the MCNF method by a low-computing time similar to the FFT phase-unwrapping method. Moreover, since the proposed algorithm is simple, fast, and user-free, it could be used in metrological interferometric and fringe-projection automatic real-time applications.
Characterization of biofilms with a fiber optic spectrometer
NASA Astrophysics Data System (ADS)
Krautwald, S.; Tonyali, A.; Fellerhoff, B.; Franke, Hilmar; Tamachkiarov, A.; Griebe, T.; Flemming, H. C.
2000-12-01
Optical sensing is one promising approach to monitor bioflims in an early stage. Generally, natural bioflims are quite inhomogeneous, therefore we start the investigation with suspensions of dead bacteria in water as a simple model for a bioflim. An experimental arrangement based on a white light fiber optic spectrometer is used for measuring the density of a thin film with a local resolution in the order of several tim. The method is applied with model biofilms. In a computer controlled procedure reflectance spectra may be recorded at different positions in the x-y plane. Scanning through thin suspension regions of bacteria between glass plates allows an estimation of the refractive index of bacteria. Taking advantage of the light collecting property of the glass substrate a simple measurement of the fluorescence with local resolution is demonstrated as well.
NASA Astrophysics Data System (ADS)
Liang, Yan-Yu; Bao, Shu-Juan; Li, Hu-Lin
2006-07-01
A series of spinel-structured materials have been prepared by a simple hydrothermal procedure in an aqueous medium. The new synthetic method is time and energy saving i.e., no further thermal treatment and extended grinding. The main experimental process involved the insertion of lithium into electrolytic manganese dioxide with glucose as a mild reductant in an autoclave. Both the hydrothermal temperature and the presence of glucose play the critical roles in determining the final spinel integrity. Particular electrochemical performance has also been systematically explored, and the results show that Al 3+, F - co-substituted spinels have the best combination of initial capacity and capacity retention among all these samples, exhibited the initial capacity of 115 mAh/g and maintained more than 90% of the initial value at the 50th cycle.
Recognition of Simple 3D Geometrical Objects under Partial Occlusion
NASA Astrophysics Data System (ADS)
Barchunova, Alexandra; Sommer, Gerald
In this paper we present a novel procedure for contour-based recognition of partially occluded three-dimensional objects. In our approach we use images of real and rendered objects whose contours have been deformed by a restricted change of the viewpoint. The preparatory part consists of contour extraction, preprocessing, local structure analysis and feature extraction. The main part deals with an extended construction and functionality of the classifier ensemble Adaptive Occlusion Classifier (AOC). It relies on a hierarchical fragmenting algorithm to perform a local structure analysis which is essential when dealing with occlusions. In the experimental part of this paper we present classification results for five classes of simple geometrical figures: prism, cylinder, half cylinder, a cube, and a bridge. We compare classification results for three classical feature extractors: Fourier descriptors, pseudo Zernike and Zernike moments.
Mazoure, Bogdan; Caraus, Iurie; Nadon, Robert; Makarenkov, Vladimir
2018-06-01
Data generated by high-throughput screening (HTS) technologies are prone to spatial bias. Traditionally, bias correction methods used in HTS assume either a simple additive or, more recently, a simple multiplicative spatial bias model. These models do not, however, always provide an accurate correction of measurements in wells located at the intersection of rows and columns affected by spatial bias. The measurements in these wells depend on the nature of interaction between the involved biases. Here, we propose two novel additive and two novel multiplicative spatial bias models accounting for different types of bias interactions. We describe a statistical procedure that allows for detecting and removing different types of additive and multiplicative spatial biases from multiwell plates. We show how this procedure can be applied by analyzing data generated by the four HTS technologies (homogeneous, microorganism, cell-based, and gene expression HTS), the three high-content screening (HCS) technologies (area, intensity, and cell-count HCS), and the only small-molecule microarray technology available in the ChemBank small-molecule screening database. The proposed methods are included in the AssayCorrector program, implemented in R, and available on CRAN.
NASA Astrophysics Data System (ADS)
Hodgson, Steven C.; Orbell, John D.; Bigger, Stephen W.; Scheirs, John
2000-06-01
A simple project is described for introducing students to some experimental procedures commonly used to measure the effects of thermal treatment on synthetic polymers. The thermally induced changes that occur in the commodity polymers low-density polyethylene (LDPE), poly(ethylene terephthalate) (PET), and poly(vinyl chloride) (PVC) are examined as a function of the time of thermal treatment in an air-circulating oven. In particular, simple procedures are described for determining (i) the polymer hydroperoxide (POOH) content and carbonyl index (CI) of LDPE, (ii) the extent of whitening of PET, and (iii) the extent of discoloration or "yellowing" of PVC, all of which change during thermal treatment. The POOH content of LDPE is determined using a ferrometric method and the CI of this polymer is measured by both Fourier transform infrared spectroscopy and a staining technique involving 2,4-dinitrophenylhydrazine. The thermal oxidation of LDPE and the kinetics of formation of its POOH and carbonyl species are discussed with reference to the accepted mechanism for the autooxidation of polyolefins. The whitening of PET and the yellowing of PVC during thermal treatment are explained by means of a crystallization process and a "zip" dehydrochlorination reaction, respectively.
Analytical and experimental study of vibrations in a gear transmission
NASA Technical Reports Server (NTRS)
Choy, F. K.; Ruan, Y. F.; Zakrajsek, J. J.; Oswald, Fred B.; Coy, J. J.
1991-01-01
An analytical simulation of the dynamics of a gear transmission system is presented and compared to experimental results from a gear noise test rig at the NASA Lewis Research Center. The analytical procedure developed couples the dynamic behaviors of the rotor-bearing-gear system with the response of the gearbox structure. The modal synthesis method is used in solving the overall dynamics of the system. Locally each rotor-gear stage is modeled as an individual rotor-bearing system using the matrix transfer technique. The dynamics of each individual rotor are coupled with other rotor stages through the nonlinear gear mesh forces and with the gearbox structure through bearing support systems. The modal characteristics of the gearbox structure are evaluated using the finite element procedure. A variable time steping integration routine is used to calculate the overall time transient behavior of the system in modal coordinates. The global dynamic behavior of the system is expressed in a generalized coordinate system. Transient and steady state vibrations of the gearbox system are presented in the time and frequency domains. The vibration characteristics of a simple single mesh gear noise test rig is modeled. The numerical simulations are compared to experimental data measured under typical operating conditions. The comparison of system natural frequencies, peak vibration amplitudes, and gear mesh frequencies are generally in good agreement.
Brown, Erik Thorson; Stallard, Robert F.; Larsen, Matthew C.; Raisbeck, Grant M.; Yiou, Francoise
1995-01-01
We present a simple method for estimation of long-term mean denudation rates using in situ-produced cosmogenic 10Be in fluvial sediments. Procedures are discussed to account for the effects of soil bioturbation, mass wasting and attenuation of cosmic rays by biomass and by local topography. Our analyses of 10Be in quartz from bedrock outcrops, soils, mass-wasting sites and riverine sediment from the Icacos River basin in the Luquillo Experimental Forest, Puerto Rico, are used to characterize denudation for major landform elements in that basin. The 10Be concentration of a discharge-weighted average of size classes of river sediment corresponds to a long-term average denudation of ≈ 43 m Ma −1, consistent with mass balance results.
Beléndez, Augusto; Beléndez, Tarsicio; Neipp, Cristian; Pascual, Inmaculada
2002-11-10
A method to determine the refractive index and thickness of silver halide emulsions used in holography is presented. The emulsions are in the form of a layer of film deposited on a thick glass plate. The experimental reflectances of p-polarized light are measured as a function of the incident angles, and the values of refractive index, thickness, and extinction coefficient of the emulsion are obtained by using the theoretical equation for reflectance. As examples, five commercial holographic silver halide emulsions are analyzed. The procedure to obtain the measurements and the numerical analysis of the experimental data are simple, and agreement of the calculated reflectances, by use of the thickness and refractive index obtained, with the measured reflectances is satisfactory.
Durability assessments of concrete using electrical properties and acoustic emission testing
NASA Astrophysics Data System (ADS)
Todak, Heather N.
Premature damage deterioration has been observed in pavement joints throughout the Midwestern region of the United States. Over time, severe joint damage creates a transportation safety concern and the necessary repairs can be an extreme economic burden. The deterioration is due in part to freeze-thaw damage associated with fluid accumulation at the pavement joints. This very preventable problem is an indication that current specifications and construction practices for freeze-thaw durability of concrete are inadequate. This thesis serves to create a better understanding of moisture ingress, freeze-thaw damage mechanisms, and the effect of variations in mixture properties on freeze-thaw behavior of concrete. The concepts of the nick point degree of saturation, sorptivity rates, and critical degree of saturation are discussed. These factors contribute to service life, defined in this study as the duration of time a concrete element remains below levels of critical saturation which are required for damage development to initiate. A theoretical model and a simple experimental procedure are introduced which help determine the nick point for a series of 32 concrete mixtures with unique mixture proportions and air entrainment properties. This simple experimental procedure is also presented as a method to measure important electrical properties in order to establish the formation factor, a valuable measure of concrete transport properties. The results of freeze-thaw testing with acoustic emission monitoring are presented to help understand and quantify damage development in concrete specimens when conditioned to various degrees of saturation. This procedure was used to study the relationship between air entrainment properties and the critical degree of saturation. Applying the concepts of degree of saturation and sorptivity, a performance-based model is proposed as a new approach to specifications for freeze-thaw durability. Finally, a conceptual model is presented to illustrate the effect of various changes in mixture proportions and air void properties on service life.
Zhang, Xiao C; Bermudez, Ana M; Reddy, Pranav M; Sarpatwari, Ravi R; Chheng, Darin B; Mezoian, Taylor J; Schwartz, Victoria R; Simmons, Quinneil J; Jay, Gregory D; Kobayashi, Leo
2017-03-01
A stable and readily accessible work surface for bedside medical procedures represents a valuable tool for acute care providers. In emergency department (ED) settings, the design and implementation of traditional Mayo stands and related surface devices often limit their availability, portability, and usability, which can lead to suboptimal clinical practice conditions that may affect the safe and effective performance of medical procedures and delivery of patient care. We designed and built a novel, open-source, portable, bedside procedural surface through an iterative development process with use testing in simulated and live clinical environments. The procedural surface development project was conducted between October 2014 and June 2016 at an academic referral hospital and its affiliated simulation facility. An interdisciplinary team of emergency physicians, mechanical engineers, medical students, and design students sought to construct a prototype bedside procedural surface out of off-the-shelf hardware during a collaborative university course on health care design. After determination of end-user needs and core design requirements, multiple prototypes were fabricated and iteratively modified, with early variants featuring undermattress stabilizing supports or ratcheting clamp mechanisms. Versions 1 through 4 underwent 2 hands-on usability-testing simulation sessions; version 5 was presented at a design critique held jointly by a panel of clinical and industrial design faculty for expert feedback. Responding to select feedback elements over several surface versions, investigators arrived at a near-final prototype design for fabrication and use testing in a live clinical setting. This experimental procedural surface (version 8) was constructed and then deployed for controlled usability testing against the standard Mayo stands in use at the study site ED. Clinical providers working in the ED who opted to participate in the study were provided with the prototype surface and just-in-time training on its use when performing bedside procedures. Subjects completed the validated 10-point System Usability Scale postshift for the surface that they had used. The study protocol was approved by the institutional review board. Multiple prototypes and recursive design revisions resulted in a fully functional, portable, and durable bedside procedural surface that featured a stainless steel tray and intuitive hook-and-lock mechanisms for attachment to ED stretcher bed rails. Forty-two control and 40 experimental group subjects participated and completed questionnaires. The median System Usability Scale score (out of 100; higher scores associated with better usability) was 72.5 (interquartile range [IQR] 51.3 to 86.3) for the Mayo stand; the experimental surface was scored at 93.8 (IQR 84.4 to 97.5 for a difference in medians of 17.5 (95% confidence interval 10 to 27.5). Subjects reported several usability challenges with the Mayo stand; the experimental surface was reviewed as easy to use, simple, and functional. In accordance with experimental live environment deployment, questionnaire responses, and end-user suggestions, the project team finalized the design specification for the experimental procedural surface for open dissemination. An iterative, interdisciplinary approach was used to generate, evaluate, revise, and finalize the design specification for a new procedural surface that met all core end-user requirements. The final surface design was evaluated favorably on a validated usability tool against Mayo stands when use tested in simulated and live clinical settings. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator
Moses, Matthew S.; Murphy, Ryan J.; Kutzer, Michael D. M.; Armand, Mehran
2016-01-01
This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy. PMID:27818607
Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator.
Moses, Matthew S; Murphy, Ryan J; Kutzer, Michael D M; Armand, Mehran
2015-12-01
This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy.
A Focusing Method in the Calibration Process of Image Sensors Based on IOFBs
Fernández, Pedro R.; Lázaro, José L.; Gardel, Alfredo; Cano, Ángel E.; Bravo, Ignacio
2010-01-01
A focusing procedure in the calibration process of image sensors based on Incoherent Optical Fiber Bundles (IOFBs) is described using the information extracted from fibers. These procedures differ from any other currently known focusing method due to the non spatial in-out correspondence between fibers, which produces a natural codification of the image to transmit. Focus measuring is essential prior to carrying out calibration in order to guarantee accurate processing and decoding. Four algorithms have been developed to estimate the focus measure; two methods based on mean grey level, and the other two based on variance. In this paper, a few simple focus measures are defined and compared. Some experimental results referred to the focus measure and the accuracy of the developed methods are discussed in order to demonstrate its effectiveness. PMID:22315526
NASA Technical Reports Server (NTRS)
1980-01-01
A simple procedure to evaluate actual evaporation was derived by linearizing the surface energy balance equation, using Taylor's expansion. The original multidimensional hypersurface could be reduced to a linear relationship between evaporation and surface temperature or to a surface relationship involving evaporation, surface temperature and albedo. This procedure permits a rapid sensitivity analysis of the surface energy balance equation as well as a speedy mapping of evaporation from remotely sensed surface temperatures and albedo. Comparison with experimental data yielded promising results. The validity of evapotranspiration and soil moisture models in semiarid conditions was tested. Wheat was the crop chosen for a continuous measurement campaign made in the south of Italy. Radiometric, micrometeorologic, agronomic and soil data were collected for processing and interpretation.
Solvent-Ion Interactions in Salt Water: A Simple Experiment.
ERIC Educational Resources Information Center
Willey, Joan D.
1984-01-01
Describes a procedurally quick, simple, and inexpensive experiment which illustrates the magnitude and some effects of solvent-ion interactions in aqueous solutions. Theoretical information, procedures, and examples of temperature, volume and hydration number calculations are provided. (JN)
Nanofrictional behavior of amorphous, polycrystalline and textured Y-Cr-O films
NASA Astrophysics Data System (ADS)
Gervacio-Arciniega, J. J.; Flores-Ruiz, F. J.; Diliegros-Godines, C. J.; Broitman, E.; Enriquez-Flores, C. I.; Espinoza-Beltrán, F. J.; Siqueiros, J.; Cruz, M. P.
2016-08-01
Differences in friction coefficients (μ) of ferroelectric YCrO3, textured and polycrystalline films, and non-ferroelectric Y-Cr-O films are analyzed. The friction coefficient was evaluated by atomic force microscopy using a simple quantitative procedure where the dependence of friction force with the applied load is obtained in only one topographical image. A simple code was developed with the MATLAB® software to analyze the experimental data. The code includes a correction of the hysteresis in the forward and backward scanning directions. The quantification of load exerted on the sample surface was obtained by finite element analysis of the AFM cantilever starting from its experimental dynamic information. The results show that the ferroelectric YCrO3 film deposited on a Pt(150 nm)/TiO2(30 nm)/SiO2/Si (100) substrate is polycrystalline and has a lower friction coefficient than the deposited on SrTiO3 (110), which is highly textured. From a viewpoint of industrial application in ferroelectric memories, where the writing process is electrical or mechanically achieved by sliding AFM tips on the sample, polycrystalline YCrO3 films seem to be the best candidates due to their lower μ.
Asymptotic formulae for likelihood-based tests of new physics
NASA Astrophysics Data System (ADS)
Cowan, Glen; Cranmer, Kyle; Gross, Eilam; Vitells, Ofer
2011-02-01
We describe likelihood-based statistical tests for use in high energy physics for the discovery of new phenomena and for construction of confidence intervals on model parameters. We focus on the properties of the test procedures that allow one to account for systematic uncertainties. Explicit formulae for the asymptotic distributions of test statistics are derived using results of Wilks and Wald. We motivate and justify the use of a representative data set, called the "Asimov data set", which provides a simple method to obtain the median experimental sensitivity of a search or measurement as well as fluctuations about this expectation.
Design Guidelines for Quiet Fans and Pumps for Space Vehicles
NASA Technical Reports Server (NTRS)
Lovell, John S.; Magliozzi, Bernard
2008-01-01
This document presents guidelines for the design of quiet fans and pumps of the class used on space vehicles. A simple procedure is presented for the prediction of fan noise over the meaningful frequency spectrum. A section also presents general design criteria for axial flow fans, squirrel cage fans, centrifugal fans, and centrifugal pumps. The basis for this report is an experimental program conducted by Hamilton Standard under NASA Contract NAS 9-12457. The derivations of the noise predicting methods used in this document are explained in Hamilton Standard Report SVHSER 6183, "Fan and Pump Noise Control," dated May 1973 (6).
Nasrollahzadeh, Mahmoud; Sajadi, S Mohammad; Rostami-Vartooni, Akbar; Khalaj, Mehdi
2015-09-01
In this paper, we report the preparation of Natrolite zeolite supported copper nanoparticles as a heterogeneous catalyst for 1,3-diploar cycloaddition and synthesis aryl nitriles from aryl iodides under ligand-free conditions. The catalyst was characterized using XRD, SEM, TEM, EDS and TG-DTA. The experimental procedure is simple, the products are formed in high yields and the catalyst can be recycled and reused several times without any significant loss of catalytic activity. Copyright © 2015 Elsevier Inc. All rights reserved.
Linearization of the bradford protein assay.
Ernst, Orna; Zor, Tsaffrir
2010-04-12
Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.
Enhanced Impurity-Free Intermixing Bandgap Engineering for InP-Based Photonic Integrated Circuits
NASA Astrophysics Data System (ADS)
Cui, Xiao; Zhang, Can; Liang, Song; Zhu, Hong-Liang; Hou, Lian-Ping
2014-04-01
Impurity-free intermixing of InGaAsP multiple quantum wells (MQW) using sputtering Cu/SiO2 layers followed by rapid thermal processing (RTP) is demonstrated. The bandgap energy could be modulated by varying the sputtering power and time of Cu, RTP temperature and time to satisfy the demands for lasers, modulators, photodetector, and passive waveguides for the photonic integrated circuits with a simple procedure. The blueshift of the bandgap wavelength of MQW is experimentally investigated on different sputtering and annealing conditions. It is obvious that the introduction of the Cu layer could increase the blueshift more greatly than the common impurity free vacancy disordering technique. A maximum bandgap blueshift of 172 nm is realized with an annealing condition of 750°C and 200s. The improved technique is promising for the fabrication of the active/passive optoelectronic components on a single wafer with simple process and low cost.
A Simple and Reliable Setup for Monitoring Corrosion Rate of Steel Rebars in Concrete
Jibran, Mohammed Abdul Azeem; Azad, Abul Kalam
2014-01-01
The accuracy in the measurement of the rate of corrosion of steel in concrete depends on many factors. The high resistivity of concrete makes the polarization data erroneous due to the Ohmic drop. The other source of error is the use of an arbitrarily assumed value of the Stern-Geary constant for calculating corrosion current density. This paper presents the outcomes of a research work conducted to develop a reliable and low-cost experimental setup and a simple calculation procedure that can be utilised to calculate the corrosion current density considering the Ohmic drop compensation and the actual value of the Stern-Geary constants calculated using the polarization data. The measurements conducted on specimens corroded to different levels indicate the usefulness of the developed setup to determine the corrosion current density with and without Ohmic drop compensation. PMID:24526907
SCEW: a Microsoft Excel add-in for easy creation of survival curves.
Khan, Haseeb Ahmad
2006-07-01
Survival curves are frequently used for reporting survival or mortality outcomes of experimental pharmacological/toxicological studies and of clinical trials. Microsoft Excel is a simple and widely used tool for creation of numerous types of graphic presentations however it is difficult to create step-wise survival curves in Excel. Considering the familiarity of clinicians and biomedical scientists with Excel, an algorithm survival curves in Excel worksheet (SCEW) has been developed for easy creation of survival curves directly in Excel worksheets. The algorithm has been integrated in the form of Excel add-in for easy installation and usage. The program is based on modification of frequency data for binary break-up using the spreadsheet formula functions whereas a macro subroutine automates the creation of survival curves. The advantages of this program are simple data input, minimal procedural steps and the creation of survival curves in the familiar confines of Excel.
NASA Technical Reports Server (NTRS)
Sellers, Piers J.; Shuttleworth, W. James; Dorman, Jeff L.; Dalcher, Amnon; Roberts, John M.
1989-01-01
Using meteorological and hydrological measurements taken in and above the central-Amazon-basin tropical forest, calibration of the Sellers et al. (1986) simple biosphere (SiB) model are described. The SiB model is a one-dimensional soil-vegetation-atmosphere model designed for use within GCMs models, representing the vegetation cover by analogy with processes operating within a single representative plant. The experimental systems and the procedures used to obtain field data are described, together with the specification of the physiological parameterization required to provide an average description of data. It was found that some of the existing literature on stomatal behavior for tropical species is inconsistent with the observed behavior of the complete canopy in Amazonia, and that the rainfall interception store of the canopy is considerably smaller than originally specified in the SiB model.
NASA Astrophysics Data System (ADS)
Nandiyanto, A. B. D.; Wiryani, A. S.; Rusli, A.; Purnamasari, A.; Abdullah, A. G.; Ana; Widiaty, I.; Hurriyati, R.
2017-03-01
Curcumin is one of the pigments which is used as a spice in Asian cuisine, traditional cosmetic, and medicine. Therefore, process for getting curcumin has been widely studied. Here, the purpose of this study was to demonstrate the simple method for extracting curcumin from Indonesian local turmeric and investigate the infrared spectra and thermal decomposition properties. In the experimental procedure, the washed turmeric was dissolved into an ethanol solution, and then put into a rotary evaporator to enrich curcumin concentration. The result showed that the present method is effective to isolate curcumin compound from Indonesian local turmeric. Since the process is very simple, this method can be used for home industrial application. Further, understanding the thermal decomposition properties of curcumin give information, specifically relating to the selection of treatment when curcumin must face the thermal-related process.
Evaluation of Bayesian Sequential Proportion Estimation Using Analyst Labels
NASA Technical Reports Server (NTRS)
Lennington, R. K.; Abotteen, K. M. (Principal Investigator)
1980-01-01
The author has identified the following significant results. A total of ten Large Area Crop Inventory Experiment Phase 3 blind sites and analyst-interpreter labels were used in a study to compare proportional estimates obtained by the Bayes sequential procedure with estimates obtained from simple random sampling and from Procedure 1. The analyst error rate using the Bayes technique was shown to be no greater than that for the simple random sampling. Also, the segment proportion estimates produced using this technique had smaller bias and mean squared errors than the estimates produced using either simple random sampling or Procedure 1.
Measurement of g using a magnetic pendulum and a smartphone magnetometer
NASA Astrophysics Data System (ADS)
Pili, Unofre; Violanda, Renante; Ceniza, Claude
2018-04-01
The internal sensors in smartphones for their advanced add-in functions have also paved the way for these gadgets becoming multifunctional tools in elementary experimental physics. For instance, the acceleration sensor has been used to analyze free-falling motion and to study the oscillations of a spring-mass system. The ambient light sensor on the other hand has been proven to be a capable tool in studying an astronomical phenomenon as well as in measuring speed and acceleration. In this paper we present an accurate, convenient, and engaging use of the smartphone magnetic field sensor to measure the acceleration due to gravity via measurement of the period of oscillations (simply called "period" in what follows) of a simple pendulum. Measurement of the gravitational acceleration via the simple pendulum is a standard elementary physics laboratory activity, but the employment of the magnetic field sensor of a smartphone device in measuring the period is quite new and the use of it is seen as fascinating among students. The setup and procedure are rather simple and can easily be replicated as a classroom demonstration or as a regular laboratory activity.
Simple effective rule to estimate the jamming packing fraction of polydisperse hard spheres.
Santos, Andrés; Yuste, Santos B; López de Haro, Mariano; Odriozola, Gerardo; Ogarko, Vitaliy
2014-04-01
A recent proposal in which the equation of state of a polydisperse hard-sphere mixture is mapped onto that of the one-component fluid is extrapolated beyond the freezing point to estimate the jamming packing fraction ϕJ of the polydisperse system as a simple function of M1M3/M22, where Mk is the kth moment of the size distribution. An analysis of experimental and simulation data of ϕJ for a large number of different mixtures shows a remarkable general agreement with the theoretical estimate. To give extra support to the procedure, simulation data for seventeen mixtures in the high-density region are used to infer the equation of state of the pure hard-sphere system in the metastable region. An excellent collapse of the inferred curves up to the glass transition and a significant narrowing of the different out-of-equilibrium glass branches all the way to jamming are observed. Thus, the present approach provides an extremely simple criterion to unify in a common framework and to give coherence to data coming from very different polydisperse hard-sphere mixtures.
Brainstorming: weighted voting prediction of inhibitors for protein targets.
Plewczynski, Dariusz
2011-09-01
The "Brainstorming" approach presented in this paper is a weighted voting method that can improve the quality of predictions generated by several machine learning (ML) methods. First, an ensemble of heterogeneous ML algorithms is trained on available experimental data, then all solutions are gathered and a consensus is built between them. The final prediction is performed using a voting procedure, whereby the vote of each method is weighted according to a quality coefficient calculated using multivariable linear regression (MLR). The MLR optimization procedure is very fast, therefore no additional computational cost is introduced by using this jury approach. Here, brainstorming is applied to selecting actives from large collections of compounds relating to five diverse biological targets of medicinal interest, namely HIV-reverse transcriptase, cyclooxygenase-2, dihydrofolate reductase, estrogen receptor, and thrombin. The MDL Drug Data Report (MDDR) database was used for selecting known inhibitors for these protein targets, and experimental data was then used to train a set of machine learning methods. The benchmark dataset (available at http://bio.icm.edu.pl/∼darman/chemoinfo/benchmark.tar.gz ) can be used for further testing of various clustering and machine learning methods when predicting the biological activity of compounds. Depending on the protein target, the overall recall value is raised by at least 20% in comparison to any single machine learning method (including ensemble methods like random forest) and unweighted simple majority voting procedures.
Prevalidation in pharmaceutical analysis. Part I. Fundamentals and critical discussion.
Grdinić, Vladimir; Vuković, Jadranka
2004-05-28
A complete prevalidation, as a basic prevalidation strategy for quality control and standardization of analytical procedure was inaugurated. Fast and simple, the prevalidation methodology based on mathematical/statistical evaluation of a reduced number of experiments (N < or = 24) was elaborated and guidelines as well as algorithms were given in detail. This strategy has been produced for the pharmaceutical applications and dedicated to the preliminary evaluation of analytical methods where linear calibration model, which is very often occurred in practice, could be the most appropriate to fit experimental data. The requirements presented in this paper should therefore help the analyst to design and perform the minimum number of prevalidation experiments needed to obtain all the required information to evaluate and demonstrate the reliability of its analytical procedure. In complete prevalidation process, characterization of analytical groups, checking of two limiting groups, testing of data homogeneity, establishment of analytical functions, recognition of outliers, evaluation of limiting values and extraction of prevalidation parameters were included. Moreover, system of diagnosis for particular prevalidation step was suggested. As an illustrative example for demonstration of feasibility of prevalidation methodology, among great number of analytical procedures, Vis-spectrophotometric procedure for determination of tannins with Folin-Ciocalteu's phenol reagent was selected. Favourable metrological characteristics of this analytical procedure, as prevalidation figures of merit, recognized the metrological procedure as a valuable concept in preliminary evaluation of quality of analytical procedures.
Ruas, Alexandre; Bernard, Olivier; Caniffi, Barbara; Simonin, Jean-Pierre; Turq, Pierre; Blum, Lesser; Moisy, Philippe
2006-02-23
This work is aimed at a description of the thermodynamic properties of highly concentrated aqueous solutions of uranyl nitrate at 25 degrees C. A new resolution of the binding mean spherical approximation (BIMSA) theory, taking into account 1-1 and also 1-2 complex formation, is developed and used to reproduce, from a simple procedure, experimental uranyl nitrate osmotic coefficient variation with concentration. For better consistency of the theory, binary uranyl perchlorate and chloride osmotic coefficients are also calculated. Comparison of calculated and experimental values is made. The possibility of regarding the ternary system UO(2)(NO(3))(2)/HNO(3)/H(2)O as a "simple" solution (in the sense of Zdanovskii, Stokes, and Robinson) is examined from water activity and density measurements. Also, an analysis of existing uranyl nitrate binary data is proposed and compared with our obtained data. On the basis of the concept of "simple" solution, values for density and water activity for the binary system UO(2)(NO(3))(2)/H(2)O are proposed in a concentration range on which uranyl nitrate precipitates from measurements on concentrated solutions of the ternary system UO(2)(NO(3))(2)/HNO(3)/H(2)O. This new set of binary data is "fictive" in the sense that the real binary system is not stable chemically. Finally, a new, interesting predictive capability of the BIMSA theory is shown.
A Simple Method for Automated Equilibration Detection in Molecular Simulations.
Chodera, John D
2016-04-12
Molecular simulations intended to compute equilibrium properties are often initiated from configurations that are highly atypical of equilibrium samples, a practice which can generate a distinct initial transient in mechanical observables computed from the simulation trajectory. Traditional practice in simulation data analysis recommends this initial portion be discarded to equilibration, but no simple, general, and automated procedure for this process exists. Here, we suggest a conceptually simple automated procedure that does not make strict assumptions about the distribution of the observable of interest in which the equilibration time is chosen to maximize the number of effectively uncorrelated samples in the production timespan used to compute equilibrium averages. We present a simple Python reference implementation of this procedure and demonstrate its utility on typical molecular simulation data.
A simple method for automated equilibration detection in molecular simulations
Chodera, John D.
2016-01-01
Molecular simulations intended to compute equilibrium properties are often initiated from configurations that are highly atypical of equilibrium samples, a practice which can generate a distinct initial transient in mechanical observables computed from the simulation trajectory. Traditional practice in simulation data analysis recommends this initial portion be discarded to equilibration, but no simple, general, and automated procedure for this process exists. Here, we suggest a conceptually simple automated procedure that does not make strict assumptions about the distribution of the observable of interest, in which the equilibration time is chosen to maximize the number of effectively uncorrelated samples in the production timespan used to compute equilibrium averages. We present a simple Python reference implementation of this procedure, and demonstrate its utility on typical molecular simulation data. PMID:26771390
Experimental implementation of the Bacon-Shor code with 10 entangled photons
NASA Astrophysics Data System (ADS)
Gimeno-Segovia, Mercedes; Sanders, Barry C.
The number of qubits that can be effectively controlled in quantum experiments is growing, reaching a regime where small quantum error-correcting codes can be tested. The Bacon-Shor code is a simple quantum code that protects against the effect of an arbitrary single-qubit error. In this work, we propose an experimental implementation of said code in a post-selected linear optical setup, similar to the recently reported 10-photon GHZ generation experiment. In the procedure we propose, an arbitrary state is encoded into the protected Shor code subspace, and after undergoing a controlled single-qubit error, is successfully decoded. BCS appreciates financial support from Alberta Innovates, NSERC, China's 1000 Talent Plan and the Institute for Quantum Information and Matter, which is an NSF Physics Frontiers Center(NSF Grant PHY-1125565) with support of the Moore Foundation(GBMF-2644).
NASA Astrophysics Data System (ADS)
Lemus-Mondaca, Roberto A.; Vega-Gálvez, Antonio; Zambra, Carlos E.; Moraga, Nelson O.
2017-01-01
A 3D model considering heat and mass transfer for food dehydration inside a direct contact dryer is studied. The k- ɛ model is used to describe turbulent air flow. The samples thermophysical properties as density, specific heat, and thermal conductivity are assumed to vary non-linearly with temperature. FVM, SIMPLE algorithm based on a FORTRAN code are used. Results unsteady velocity, temperature, moisture, kinetic energy and dissipation rate for the air flow are presented, whilst temperature and moisture values for the food also are presented. The validation procedure includes a comparison with experimental and numerical temperature and moisture content results obtained from experimental data, reaching a deviation 7-10 %. In addition, this turbulent k- ɛ model provided a better understanding of the transport phenomenon inside the dryer and sample.
Numerical simulation of damage evolution for ductile materials and mechanical properties study
NASA Astrophysics Data System (ADS)
El Amri, A.; Hanafi, I.; Haddou, M. E. Y.; Khamlichi, A.
2015-12-01
This paper presents results of a numerical modelling of ductile fracture and failure of elements made of 5182H111 aluminium alloys subjected to dynamic traction. The analysis was performed using Johnson-Cook model based on ABAQUS software. The modelling difficulty related to prediction of ductile fracture mainly arises because there is a tremendous span of length scales from the structural problem to the micro-mechanics problem governing the material separation process. This study has been used the experimental results to calibrate a simple crack propagation criteria for shell elements of which one has often been used in practical analyses. The performance of the proposed model is in general good and it is believed that the presented results and experimental-numerical calibration procedure can be of use in practical finite-element simulations.
How-to-Do-It: A Simple DNA Isolation Technique Using Halophilic Bacteria.
ERIC Educational Resources Information Center
Guilfoile, Patrick
1989-01-01
Described is a simple technique for isolating DNA from halophilic bacteria. Materials, procedure, and additional experiments are outlined. It is stated that the DNA obtained will be somewhat contaminated with cellular proteins and RNA. Offers a procedure for greater purification. (RT)
NASA Astrophysics Data System (ADS)
Chasalevris, Athanasios; Dohnal, Fadi
2015-02-01
The idea for a journal bearing with variable geometry was formerly developed and investigated on its principles of operation giving very optimistic theoretical results for the vibration quenching of simple and more complicated rotor bearing systems during the passage through the first critical speed. The journal bearing with variable geometry is presented in this paper in its final form with the detailed design procedure. The current journal bearing was constructed in order to be applied in a simple real rotor bearing system that already exists as an experimental facility. The current paper presents details on the manufactured prototype bearing as an experimental continuation of previous works that presented the simulation of the operating principle of this journal bearing. The design parameters are discussed thoroughly under the numerical simulation for the fluid film pressure in dependency of the variable fluid film thickness during the operation conditions. The implementation of the variable geometry bearing in an experimental rotor bearing system is outlined. Various measurements highlight the efficiency of the proposed bearing element in vibration quenching during the passage through resonance. The inspiration for the current idea is based on the fact that the alteration of the fluid film characteristics of stiffness and damping during the passage through resonance results in vibration quenching. This alteration of the bearing characteristics is achieved by the introduction of an additional fluid film thickness using the passive displacement of the lower half-bearing part. • The contribution of the current journal bearing in vibration quenching. • Experimental evidence for the VGJB contribution.
Nonlinear least-squares data fitting in Excel spreadsheets.
Kemmer, Gerdi; Keller, Sandro
2010-02-01
We describe an intuitive and rapid procedure for analyzing experimental data by nonlinear least-squares fitting (NLSF) in the most widely used spreadsheet program. Experimental data in x/y form and data calculated from a regression equation are inputted and plotted in a Microsoft Excel worksheet, and the sum of squared residuals is computed and minimized using the Solver add-in to obtain the set of parameter values that best describes the experimental data. The confidence of best-fit values is then visualized and assessed in a generally applicable and easily comprehensible way. Every user familiar with the most basic functions of Excel will be able to implement this protocol, without previous experience in data fitting or programming and without additional costs for specialist software. The application of this tool is exemplified using the well-known Michaelis-Menten equation characterizing simple enzyme kinetics. Only slight modifications are required to adapt the protocol to virtually any other kind of dataset or regression equation. The entire protocol takes approximately 1 h.
Equation of state for detonation product gases
NASA Astrophysics Data System (ADS)
Nagayama, Kunihito; Kubota, Shiro
2003-03-01
A thermodynamic analysis procedure of the detonation product equation of state (EOS) together with the experimental data set of the detonation velocity as a function of initial density has been formulated. The Chapman-Jouguet (CJ) state [W. Ficket and W. C. Davis, Detonation: Theory and Experiment (University of California Press, Berkeley 1979)] on the p-ν plane is found to be well approximated by the envelope function formed by the collection of Rayleigh lines with many different initial density states. The Jones-Stanyukovich-Manson relation [W. Ficket and W. C. Davis, Detonation: Theory and Experiment (University of California Press, Berkeley, 1979)] is used to estimate the error included in this approximation. Based on this analysis, a simplified integration method to calculate the Grüneisen parameter along the CJ state curve with different initial densities utilizing the cylinder expansion data has been presented. The procedure gives a simple way of obtaining the EOS function, compatible with the detonation velocity data. Theoretical analysis has been performed for the precision of the estimated EOS function. EOS of the pentaerithrytoltetranitrate explosive is calculated and compared with some of the experimental data such as CJ pressure data and cylinder expansion data.
THREE-STAGE ANALYSIS OF BLOOD COAGULATION
Milstone, J. H.
1948-01-01
1. Blood-clotting mechanism has been analyzed by a procedure which devotes a separate experimental step to each of the three primary reactions: 1. Prothrombokinase → thrombokinase 2. Prothrombin → thrombin 3. Fibrinogen → fibrin 2. Activation of prothrombin by thrombokinase followed the course of a unimolecular reaction, and the concentration of thrombokinase determined the initial rate. By this relation thrombokinase was measured, and the activation of its precursor was charted. 3. When the activation of prothrombokinase was plotted against time, the experimental points fell close to the theoretical curve for a simple autocatalytic reaction. Moreover, the process was accelerated by seeding with a small amount of crude thrombokinase. It was concluded that the activation of prothrombokinase involves an autocatalytic or chain reaction. 4. The three-stage procedure made possible the separate estimation of the power to activate prothrombin, on one hand, and the capacity to accelerate the transformation of prothrombokinase on the other. Drastic losses of both activities occurred when crude thrombokinase solutions were heated at 60°C., or adsorbed with barium sulfate. 5. The concentration of calcium was important for the normal progress of prothrombin activation, and also for the transformation of prothrombokinase. PMID:18904755
Control of the Pore Texture in Nanoporous Silicon via Chemical Dissolution.
Secret, Emilie; Wu, Chia-Chen; Chaix, Arnaud; Galarneau, Anne; Gonzalez, Philippe; Cot, Didier; Sailor, Michael J; Jestin, Jacques; Zanotti, Jean-Marc; Cunin, Frédérique; Coasne, Benoit
2015-07-28
The surface and textural properties of porous silicon (pSi) control many of its physical properties essential to its performance in key applications such as optoelectronics, energy storage, luminescence, sensing, and drug delivery. Here, we combine experimental and theoretical tools to demonstrate that the surface roughness at the nanometer scale of pSi can be tuned in a controlled fashion using partial thermal oxidation followed by removal of the resulting silicon oxide layer with hydrofluoric acid (HF) solution. Such a process is shown to smooth the pSi surface by means of nitrogen adsorption, electron microscopy, and small-angle X-ray and neutron scattering. Statistical mechanics Monte Carlo simulations, which are consistent with the experimental data, support the interpretation that the pore surface is initially rough and that the oxidation/oxide removal procedure diminishes the surface roughness while increasing the pore diameter. As a specific example considered in this work, the initial roughness ξ ∼ 3.2 nm of pSi pores having a diameter of 7.6 nm can be decreased to 1.0 nm following the simple procedure above. This study allows envisioning the design of pSi samples with optimal surface properties toward a specific process.
van Laarhoven, Twan; Marchiori, Elena
2013-01-01
In silico discovery of interactions between drug compounds and target proteins is of core importance for improving the efficiency of the laborious and costly experimental determination of drug-target interaction. Drug-target interaction data are available for many classes of pharmaceutically useful target proteins including enzymes, ion channels, GPCRs and nuclear receptors. However, current drug-target interaction databases contain a small number of drug-target pairs which are experimentally validated interactions. In particular, for some drug compounds (or targets) there is no available interaction. This motivates the need for developing methods that predict interacting pairs with high accuracy also for these 'new' drug compounds (or targets). We show that a simple weighted nearest neighbor procedure is highly effective for this task. We integrate this procedure into a recent machine learning method for drug-target interaction we developed in previous work. Results of experiments indicate that the resulting method predicts true interactions with high accuracy also for new drug compounds and achieves results comparable or better than those of recent state-of-the-art algorithms. Software is publicly available at http://cs.ru.nl/~tvanlaarhoven/drugtarget2013/.
Guided mass spectrum labelling in atom probe tomography.
Haley, D; Choi, P; Raabe, D
2015-12-01
Atom probe tomography (APT) is a valuable near-atomic scale imaging technique, which yields mass spectrographic data. Experimental correctness can often pivot on the identification of peaks within a dataset, this is a manual process where subjectivity and errors can arise. The limitations of manual procedures complicate APT experiments for the operator and furthermore are a barrier to technique standardisation. In this work we explore the capabilities of computer-guided ranging to aid identification and analysis of mass spectra. We propose a fully robust algorithm for enumeration of the possible identities of detected peak positions, which assists labelling. Furthermore, a simple ranking scheme is developed to allow for evaluation of the likelihood of each possible identity being the likely assignment from the enumerated set. We demonstrate a simple, yet complete work-chain that allows for the conversion of mass-spectra to fully identified APT spectra, with the goal of minimising identification errors, and the inter-operator variance within APT experiments. This work chain is compared to current procedures via experimental trials with different APT operators, to determine the relative effectiveness and precision of the two approaches. It is found that there is little loss of precision (and occasionally gain) when participants are given computer assistance. We find that in either case, inter-operator precision for ranging varies between 0 and 2 "significant figures" (2σ confidence in the first n digits of the reported value) when reporting compositions. Intra-operator precision is weakly tested and found to vary between 1 and 3 significant figures, depending upon species composition levels. Finally it is suggested that inconsistencies in inter-operator peak labelling may be the largest source of scatter when reporting composition data in APT. Copyright © 2015 Elsevier B.V. All rights reserved.
Microscopically derived potential energy surfaces from mostly structural considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ermamatov, M.J.; Institute of Nuclear Physics, Ulughbek, Tashkent 100214; Hess, Peter O., E-mail: hess@nucleares.unam.mx
2016-08-15
A simple procedure to estimate the quadrupole Potential-Energy-Surface (PES) is presented, using mainly structural information, namely the content of the shell model space and the Pauli exclusion principle. Further microscopic properties are implicitly contained through the use of results from the Möller and Nix tables or experimental information. A mapping to the geometric potential is performed yielding the PES. The General Collective Model is used in order to obtain an estimate on the spectrum and quadrupole transitions, adjusting only the mass parameter. First, we test the conjecture on known nuclei, deriving the PES and compare them to known data. Wemore » will see that the PES approximates very well the structure expected. Having acquired a certain confidence, we predict the PES of several chain of isotopes of heavy and super-heavy nuclei and at the end we investigate the structure of nuclei in the supposed island of stability. One of the main points to show is that simple assumptions can provide already important information on the structure of nuclei outside known regions and that spectra and electromagnetic transitions can be estimated without using involved calculations and assumptions. The procedure does not allow to calculate binding energies. The method presented can be viewed as a starting point for further improvements.« less
NASA Astrophysics Data System (ADS)
Mlimandago, S.
This research paper have gone out with very simple and easy (several) new concepts in document management for space projects and programs which can be applied anywhere both in the developing and developed countries. These several new concepts are and have been applied in Tanzania, Kenya and Uganda and found out to bear very good results using simple procedures. The intergral project based its documentation management approach from the outset on electronic document sharing and archiving. The main objective of having new concepts was to provide a faster and wider availability of the most current space information to all parties rather than creating a paperless office. Implementation of the new concepts approach required the capturing of documents in an appropriate and simple electronic format at source establishing new procedures for project wide information sharing and the deployment of a new generation of simple procedure - WEB - based tools. Key success factors were the early adoption of Internet technologies and simple procedures for improved information flow new concepts which can be applied anywhere both in the developed and the developing countries.
2011-01-10
in Fig. 4, we discuss a procedure of transmutation from the simple -particle chiral element to the conjugated gammadion chiral metamaterial. The...the transmutation from the simple -particle chiral element to the conjugated gammadion chiral metamaterial. The procedure shows how the magnetic or
A simple procedure for the estimation of neutron skyshine from proton accelerators.
Stevenson, G R; Thomas, R H
1984-01-01
Recent calculations of neutron diffusion at an air/ground interface have enabled the establishment of a very simple procedure for estimating neutron dose equivalent at large distances from proton accelerators in the energy range 10 MeV to several tens of GeV.
Ghazy, S E; Samra, S E; Mahdy, A F M; El-Morsy, S M
2004-11-01
A simple and economic experimental sorptive -flotation procedure is presented for the removal of copper(II) species from aqueous solutions. It is based on using powdered marble wastes (PMW), which are widespread and inexpensive and may represent an environmental problem, as the effective inorganic sorbent and oleic (HOL) as the surfactant. The main parameters (i.e. initial solution pH, sorbent, surfactant and copper concentrations, stirring times, ionic strength, temperature and the presence of foreign ions) influencing the flotation of PMW and /or Cu(II) were examined. Nearly, 100% of PMW and Cu(II) were removed from aqueous solutions at pH7 after stirring for 10 min and at room temperature, (approximately 25 degrees C). The procedure was successfully applied to recover Cu(II) spiked to some natural water samples. A mechanism for sorption and flotation is suggested.
Flood mapping in ungauged basins using fully continuous hydrologic-hydraulic modeling
NASA Astrophysics Data System (ADS)
Grimaldi, Salvatore; Petroselli, Andrea; Arcangeletti, Ettore; Nardi, Fernando
2013-04-01
SummaryIn this work, a fully-continuous hydrologic-hydraulic modeling framework for flood mapping is introduced and tested. It is characterized by a simulation of a long rainfall time series at sub-daily resolution that feeds a continuous rainfall-runoff model producing a discharge time series that is directly given as an input to a bi-dimensional hydraulic model. The main advantage of the proposed approach is to avoid the use of the design hyetograph and the design hydrograph that constitute the main source of subjective analysis and uncertainty for standard methods. The proposed procedure is optimized for small and ungauged watersheds where empirical models are commonly applied. Results of a simple real case study confirm that this experimental fully-continuous framework may pave the way for the implementation of a less subjective and potentially automated procedure for flood hazard mapping.
Klahr, David; Nigam, Milena
2004-10-01
In a study with 112 third- and fourth-grade children, we measured the relative effectiveness of discovery learning and direct instruction at two points in the learning process: (a) during the initial acquisition of the basic cognitive objective (a procedure for designing and interpreting simple, unconfounded experiments) and (b) during the subsequent transfer and application of this basic skill to more diffuse and authentic reasoning associated with the evaluation of science-fair posters. We found not only that many more children learned from direct instruction than from discovery learning, but also that when asked to make broader, richer scientific judgments, the many children who learned about experimental design from direct instruction performed as well as those few children who discovered the method on their own. These results challenge predictions derived from the presumed superiority of discovery approaches in teaching young children basic procedures for early scientific investigations.
Optimization and automation of quantitative NMR data extraction.
Bernstein, Michael A; Sýkora, Stan; Peng, Chen; Barba, Agustín; Cobas, Carlos
2013-06-18
NMR is routinely used to quantitate chemical species. The necessary experimental procedures to acquire quantitative data are well-known, but relatively little attention has been applied to data processing and analysis. We describe here a robust expert system that can be used to automatically choose the best signals in a sample for overall concentration determination and determine analyte concentration using all accepted methods. The algorithm is based on the complete deconvolution of the spectrum which makes it tolerant of cases where signals are very close to one another and includes robust methods for the automatic classification of NMR resonances and molecule-to-spectrum multiplets assignments. With the functionality in place and optimized, it is then a relatively simple matter to apply the same workflow to data in a fully automatic way. The procedure is desirable for both its inherent performance and applicability to NMR data acquired for very large sample sets.
NASA Astrophysics Data System (ADS)
Baumgart, M.; Druml, N.; Consani, M.
2018-05-01
This paper presents a simulation approach for Time-of-Flight cameras to estimate sensor performance and accuracy, as well as to help understanding experimentally discovered effects. The main scope is the detailed simulation of the optical signals. We use a raytracing-based approach and use the optical path length as the master parameter for depth calculations. The procedure is described in detail with references to our implementation in Zemax OpticStudio and Python. Our simulation approach supports multiple and extended light sources and allows accounting for all effects within the geometrical optics model. Especially multi-object reflection/scattering ray-paths, translucent objects, and aberration effects (e.g. distortion caused by the ToF lens) are supported. The optical path length approach also enables the implementation of different ToF senor types and transient imaging evaluations. The main features are demonstrated on a simple 3D test scene.
From Phonomecanocardiography to Phonocardiography computer aided
NASA Astrophysics Data System (ADS)
Granados, J.; Tavera, F.; López, G.; Velázquez, J. M.; Hernández, R. T.; López, G. A.
2017-01-01
Due to lack of training doctors to identify many of the disorders in the heart by conventional listening, it is necessary to add an objective and methodological analysis to support this technique. In order to obtain information of the performance of the heart to be able to diagnose heart disease through a simple, cost-effective procedure by means of a data acquisition system, we have obtained Phonocardiograms (PCG), which are images of the sounds emitted by the heart. A program of acoustic, visual and artificial vision recognition was elaborated to interpret them. Based on the results of previous research of cardiologists a code of interpretation of PCG and associated diseases was elaborated. Also a site, within the university campus, of experimental sampling of cardiac data was created. Phonocardiography computer-aided is a viable and low cost procedure which provides additional medical information to make a diagnosis of complex heart diseases. We show some previous results.
An evaluation of methods for scaling aircraft noise perception
NASA Technical Reports Server (NTRS)
Ollerhead, J. B.
1971-01-01
One hundred and twenty recorded sounds, including jets, turboprops, piston engined aircraft and helicopters were rated by a panel of subjects in a paired comparison test. The results were analyzed to evaluate a number of noise rating procedures in terms of their ability to accurately estimate both relative and absolute perceived noise levels. It was found that the complex procedures developed by Stevens, Zwicker and Kryter are superior to other scales. The main advantage of these methods over the more convenient weighted sound pressure level scales lies in their ability to cope with signals over a wide range of bandwidth. However, Stevens' loudness level scale and the perceived noise level scale both overestimate the growth of perceived level with intensity because of an apparent deficiency in the band level summation rule. A simple correction is proposed which will enable these scales to properly account for the experimental observations.
Ishii, Yosuke; Biwa, Shiro
2014-07-01
An ultrasonic evaluation procedure for the interlayer interfacial normal stiffness and the intralayer longitudinal wave velocity of multilayered plate-like structures is proposed. Based on the characteristics of the amplitude reflection spectrum of ultrasonic wave at normal incidence to a layered structure with spring-type interlayer interfaces, it is shown that the interfacial normal stiffness and the longitudinal wave velocity in the layers can be simultaneously evaluated from the frequencies of local maxima and minima of the spectrum provided that all interfaces and layers have the same properties. The effectiveness of the proposed procedure is investigated from the perspective of the sensitivity of local extremal frequencies of the reflection spectrum. The feasibility of the proposed procedure is also investigated when the stiffness of each interface is subjected to small random fluctuations about a certain average value. The proposed procedure is applied to a 16-layered cross-ply carbon-fiber-reinforced composite laminate. The normal stiffness of resin-rich interfaces and the longitudinal wave velocity of plies in the thickness direction evaluated from the experimental reflection spectrum are shown to be consistent with simple theoretical estimations.
NASA Technical Reports Server (NTRS)
Hakkinen, Raimo J; Richardson, A S , Jr
1957-01-01
Sinusoidally oscillating downwash and lift produced on a simple rigid airfoil were measured and compared with calculated values. Statistically stationary random downwash and the corresponding lift on a simple rigid airfoil were also measured and the transfer functions between their power spectra determined. The random experimental values are compared with theoretically approximated values. Limitations of the experimental technique and the need for more extensive experimental data are discussed.
Combining Experiments and Simulations Using the Maximum Entropy Principle
Boomsma, Wouter; Ferkinghoff-Borg, Jesper; Lindorff-Larsen, Kresten
2014-01-01
A key component of computational biology is to compare the results of computer modelling with experimental measurements. Despite substantial progress in the models and algorithms used in many areas of computational biology, such comparisons sometimes reveal that the computations are not in quantitative agreement with experimental data. The principle of maximum entropy is a general procedure for constructing probability distributions in the light of new data, making it a natural tool in cases when an initial model provides results that are at odds with experiments. The number of maximum entropy applications in our field has grown steadily in recent years, in areas as diverse as sequence analysis, structural modelling, and neurobiology. In this Perspectives article, we give a broad introduction to the method, in an attempt to encourage its further adoption. The general procedure is explained in the context of a simple example, after which we proceed with a real-world application in the field of molecular simulations, where the maximum entropy procedure has recently provided new insight. Given the limited accuracy of force fields, macromolecular simulations sometimes produce results that are at not in complete and quantitative accordance with experiments. A common solution to this problem is to explicitly ensure agreement between the two by perturbing the potential energy function towards the experimental data. So far, a general consensus for how such perturbations should be implemented has been lacking. Three very recent papers have explored this problem using the maximum entropy approach, providing both new theoretical and practical insights to the problem. We highlight each of these contributions in turn and conclude with a discussion on remaining challenges. PMID:24586124
Simple projects guidebook : federal-aid procedure for simple projects
DOT National Transportation Integrated Search
2002-06-01
Experience has shown that a simple project generally 1) does not have any right-of-way involvement and 2) has a Programmatic Categorical Exclusion or Categorical Exclusion environmental determination. Page 7 outlines the definition of simple projects...
Webster, John
2014-01-01
Simple Summary When making a choice of species for animal experimentation we must balance its suitability as a model for human medicine against the potential harms to the animals both from the procedures and the quality of their lifetime experience. The capacity to experience pain may be similar in mammals, birds and fish. The capacity to suffer from fear is governed more by sentience than cognitive ability, so it cannot be assumed that rodents or farm animals suffer less than dogs or primates. I suggest that it is unethical to base the choice of species for animal experimentation simply on the basis that it will cause less distress within society. Abstract Ethical principles governing the conduct of experiments with animals are reviewed, especially those relating to the choice of species. Legislation requires that the potential harm to animals arising from any procedure should be assessed in advance and justified in terms of its possible benefit to society. Potential harms may arise both from the procedures and the quality of the animals’ lifetime experience. The conventional approach to species selection is to use animals with the “lowest degree of neurophysiological sensitivity”. However; this concept should be applied with extreme caution in the light of new knowledge. The capacity to experience pain may be similar in mammals, birds and fish. The capacity to suffer from fear is governed more by sentience than cognitive ability, so it cannot be assumed that rodents or farm animals suffer less than dogs or primates. I suggest that it is unethical to base the choice of species for animal experimentation simply on the basis that it will cause less distress within society. A set of responsibilities is outlined for each category of moral agent. These include regulators, operators directly concerned with the conduct of scientific experiments and toxicology trials, veterinarians and animal care staff; and society at large. PMID:26479009
NASA Astrophysics Data System (ADS)
Guchhait, Shyamal; Banerjee, Biswanath
2018-04-01
In this paper, a variant of constitutive equation error based material parameter estimation procedure for linear elastic plates is developed from partially measured free vibration sig-natures. It has been reported in many research articles that the mode shape curvatures are much more sensitive compared to mode shape themselves to localize inhomogeneity. Complying with this idea, an identification procedure is framed as an optimization problem where the proposed cost function measures the error in constitutive relation due to incompatible curvature/strain and moment/stress fields. Unlike standard constitutive equation error based procedure wherein a solution of a couple system is unavoidable in each iteration, we generate these incompatible fields via two linear solves. A simple, yet effective, penalty based approach is followed to incorporate measured data. The penalization parameter not only helps in incorporating corrupted measurement data weakly but also acts as a regularizer against the ill-posedness of the inverse problem. Explicit linear update formulas are then developed for anisotropic linear elastic material. Numerical examples are provided to show the applicability of the proposed technique. Finally, an experimental validation is also provided.
A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer.
Pagoulatos, N; Haynor, D R; Kim, Y
2001-09-01
We have developed a fast calibration method for computing the position and orientation of 2-D ultrasound (US) images in 3-D space where a position sensor is mounted on the US probe. This calibration is required in the fields of 3-D ultrasound and registration of ultrasound with other imaging modalities. Most of the existing calibration methods require a complex and tedious experimental procedure. Our method is simple and it is based on a custom-built phantom. Thirty N-fiducials (markers in the shape of the letter "N") embedded in the phantom provide the basis for our calibration procedure. We calibrated a 3.5-MHz sector phased-array probe with a magnetic position sensor, and we studied the accuracy and precision of our method. A typical calibration procedure requires approximately 2 min. We conclude that we can achieve accurate and precise calibration using a single US image, provided that a large number (approximately ten) of N-fiducials are captured within the US image, enabling a representative sampling of the imaging plane.
NASA Astrophysics Data System (ADS)
Guo, Xiaowei; Chen, Mingyong; Zhu, Jianhua; Ma, Yanqin; Du, Jinglei; Guo, Yongkang; Du, Chunlei
2006-01-01
A novel method for the fabrication of continuous micro-optical components is presented in this paper. It employs a computer controlled digital-micromirror-device(DMD TM) as a switchable projection mask and silver-halide sensitized gelatin (SHSG) as recording material. By etching SHSG with enzyme solution, the micro-optical components with relief modulation can be generated through special processing procedures. The principles of etching SHSG with enzyme and theoretical analysis for deep etching are also discussed in detail, and the detailed quantitative experiments on the processing procedures are conducted to determine optimum technique parameters. A good linear relationship within a depth range of 4μm was experimentally obtained between exposure dose and relief depth. At last, the microlensarray with 256.8μm radius and 2.572μm depth was achieved. This method is simple, cheap and the aberration in processing procedures can be corrected in the step of designing mask, so it is a practical method to fabricate good continuous profile for low-volume production.
Drop shape visualization and contact angle measurement on curved surfaces.
Guilizzoni, Manfredo
2011-12-01
The shape and contact angles of drops on curved surfaces is experimentally investigated. Image processing, spline fitting and numerical integration are used to extract the drop contour in a number of cross-sections. The three-dimensional surfaces which describe the surface-air and drop-air interfaces can be visualized and a simple procedure to determine the equilibrium contact angle starting from measurements on curved surfaces is proposed. Contact angles on flat surfaces serve as a reference term and a procedure to measure them is proposed. Such procedure is not as accurate as the axisymmetric drop shape analysis algorithms, but it has the advantage of requiring only a side view of the drop-surface couple and no further information. It can therefore be used also for fluids with unknown surface tension and there is no need to measure the drop volume. Examples of application of the proposed techniques for distilled water drops on gemstones confirm that they can be useful for drop shape analysis and contact angle measurement on three-dimensional sculptured surfaces. Copyright © 2011 Elsevier Inc. All rights reserved.
Wavefront sensor and wavefront corrector matching in adaptive optics
Dubra, Alfredo
2016-01-01
Matching wavefront correctors and wavefront sensors by minimizing the condition number and mean wavefront variance is proposed. The particular cases of two continuous-sheet deformable mirrors and a Shack-Hartmann wavefront sensor with square packing geometry are studied in the presence of photon noise, background noise and electronics noise. Optimal number of lenslets across each actuator are obtained for both deformable mirrors, and a simple experimental procedure for optimal alignment is described. The results show that high-performance adaptive optics can be achieved even with low cost off-the-shelf Shack-Hartmann arrays with lenslet spacing that do not necessarily match those of the wavefront correcting elements. PMID:19532513
Wavefront sensor and wavefront corrector matching in adaptive optics.
Dubra, Alfredo
2007-03-19
Matching wavefront correctors and wavefront sensors by minimizing the condition number and mean wavefront variance is proposed. The particular cases of two continuous-sheet deformable mirrors and a Shack-Hartmann wavefront sensor with square packing geometry are studied in the presence of photon noise, background noise and electronics noise. Optimal number of lenslets across each actuator are obtained for both deformable mirrors, and a simple experimental procedure for optimal alignment is described. The results show that high-performance adaptive optics can be achieved even with low cost off-the-shelf Shack-Hartmann arrays with lenslet spacing that do not necessarily match those of the wavefront correcting elements.
Fourier-space TEM reconstructions with symmetry adapted functions for all rotational point groups.
Trapani, Stefano; Navaza, Jorge
2013-05-01
A general-purpose and simple expression for the coefficients of symmetry adapted functions referred to conveniently oriented symmetry axes is given for all rotational point groups. The expression involves the computation of reduced Wigner-matrix elements corresponding to an angle specific to each group and has the computational advantage of leading to Fourier-space TEM (transmission electron microscopy) reconstruction procedures involving only real valued unknowns. Using this expression, a protocol for ab initio view and center assignment and reconstruction so far used for icosahedral particles has been tested with experimental data in other point groups. Copyright © 2013 Elsevier Inc. All rights reserved.
Xu, Y.; Xia, J.; Miller, R.D.
2006-01-01
Multichannel analysis of surface waves is a developing method widely used in shallow subsurface investigations. The field procedures and related parameters are very important for successful applications. Among these parameters, the source-receiver offset range is seldom discussed in theory and normally determined by empirical or semi-quantitative methods in current practice. This paper discusses the problem from a theoretical perspective. A formula for quantitatively evaluating a layered homogenous elastic model was developed. The analytical results based on simple models and experimental data demonstrate that the formula is correct for surface wave surveys for near-surface applications. ?? 2005 Elsevier B.V. All rights reserved.
Interfacial gas nanobubbles or oil nanodroplets?
Wang, Xingya; Zhao, Binyu; Hu, Jun; Wang, Shuo; Tai, Renzhong; Gao, Xingyu; Zhang, Lijuan
2017-01-04
The existence of nanobubbles at a solid-liquid interface with high stability has been confirmed by myriad experimental studies, and their gaseous nature has also been extensively verified. However, nanodroplets of polydimethylsiloxane (PDMS) recently observed in the atomic force microscopy (AFM) measurement of nanobubbles plague the nanobubble community. It may easily lead to wrong interpretations of the AFM results and thus hinders further application of the already widely used AFM in nanobubble studies. Therefore, finding a direct experimental solution to distinguish nanobubbles from nanodroplets in AFM measurements is a matter of great urgency. Herein, we first developed an effective and reproducible method to produce PDMS nanodroplets at the highly ordered pyrolytic graphite (HOPG)/water interface. From their size, contact angle, and stiffness, the formed PDMS nanodroplets are not distinguishable from nanobubbles. However, the force curves on these two objects are strikingly different from each other, i.e., a peculiar plateau in both the approach and retraction curves was found on nanobubbles whereas they changed linearly between the jump-in and jump-off point on PDMS nanodroplets. Thus, the present study not only provided a simple and effective procedure to generate PDMS nanodroplets but also paved a simple practical and in situ way to discriminate nanobubbles from the PDMS nanodroplets by direct AFM force measurements.
NASA Astrophysics Data System (ADS)
Samanta, B.; Al-Balushi, K. R.
2003-03-01
A procedure is presented for fault diagnosis of rolling element bearings through artificial neural network (ANN). The characteristic features of time-domain vibration signals of the rotating machinery with normal and defective bearings have been used as inputs to the ANN consisting of input, hidden and output layers. The features are obtained from direct processing of the signal segments using very simple preprocessing. The input layer consists of five nodes, one each for root mean square, variance, skewness, kurtosis and normalised sixth central moment of the time-domain vibration signals. The inputs are normalised in the range of 0.0 and 1.0 except for the skewness which is normalised between -1.0 and 1.0. The output layer consists of two binary nodes indicating the status of the machine—normal or defective bearings. Two hidden layers with different number of neurons have been used. The ANN is trained using backpropagation algorithm with a subset of the experimental data for known machine conditions. The ANN is tested using the remaining set of data. The effects of some preprocessing techniques like high-pass, band-pass filtration, envelope detection (demodulation) and wavelet transform of the vibration signals, prior to feature extraction, are also studied. The results show the effectiveness of the ANN in diagnosis of the machine condition. The proposed procedure requires only a few features extracted from the measured vibration data either directly or with simple preprocessing. The reduced number of inputs leads to faster training requiring far less iterations making the procedure suitable for on-line condition monitoring and diagnostics of machines.
Identification of site frequencies from building records
Celebi, M.
2003-01-01
A simple procedure to identify site frequencies using earthquake response records from roofs and basements of buildings is presented. For this purpose, data from five different buildings are analyzed using only spectral analyses techniques. Additional data such as free-field records in close proximity to the buildings and site characterization data are also used to estimate site frequencies and thereby to provide convincing evidence and confirmation of the site frequencies inferred from the building records. Furthermore, simple code-formula is used to calculate site frequencies and compare them with the identified site frequencies from records. Results show that the simple procedure is effective in identification of site frequencies and provides relatively reliable estimates of site frequencies when compared with other methods. Therefore the simple procedure for estimating site frequencies using earthquake records can be useful in adding to the database of site frequencies. Such databases can be used to better estimate site frequencies of those sites with similar geological structures.
NASA Astrophysics Data System (ADS)
Sun, Shoutian; Ramu Ramachandran, Bala; Wick, Collin D.
2018-02-01
New interatomic potentials for pure Ti and Al, and binary TiAl were developed utilizing the second nearest neighbour modified embedded-atom method (MEAM) formalism. The potentials were parameterized to reproduce multiple properties spanning bulk solids, solid surfaces, solid/liquid phase changes, and liquid interfacial properties. This was carried out using a newly developed optimization procedure that combined the simple minimization of a fitness function with a genetic algorithm to efficiently span the parameter space. The resulting MEAM potentials gave good agreement with experimental and DFT solid and liquid properties, and reproduced the melting points for Ti, Al, and TiAl. However, the surface tensions from the model consistently underestimated experimental values. Liquid TiAl’s surface was found to be mostly covered with Al atoms, showing that Al has a significant propensity for the liquid/air interface.
A simple and accurate method for calculation of the structure factor of interacting charged spheres.
Wu, Chu; Chan, Derek Y C; Tabor, Rico F
2014-07-15
Calculation of the structure factor of a system of interacting charged spheres based on the Ginoza solution of the Ornstein-Zernike equation has been developed and implemented on a stand-alone spreadsheet. This facilitates direct interactive numerical and graphical comparisons between experimental structure factors with the pioneering theoretical model of Hayter-Penfold that uses the Hansen-Hayter renormalisation correction. The method is used to fit example experimental structure factors obtained from the small-angle neutron scattering of a well-characterised charged micelle system, demonstrating that this implementation, available in the supplementary information, gives identical results to the Hayter-Penfold-Hansen approach for the structure factor, S(q) and provides direct access to the pair correlation function, g(r). Additionally, the intermediate calculations and outputs can be readily accessed and modified within the familiar spreadsheet environment, along with information on the normalisation procedure. Copyright © 2014 Elsevier Inc. All rights reserved.
Sun, Shoutian; Ramachandran, Bala Ramu; Wick, Collin D
2018-02-21
New interatomic potentials for pure Ti and Al, and binary TiAl were developed utilizing the second nearest neighbour modified embedded-atom method (MEAM) formalism. The potentials were parameterized to reproduce multiple properties spanning bulk solids, solid surfaces, solid/liquid phase changes, and liquid interfacial properties. This was carried out using a newly developed optimization procedure that combined the simple minimization of a fitness function with a genetic algorithm to efficiently span the parameter space. The resulting MEAM potentials gave good agreement with experimental and DFT solid and liquid properties, and reproduced the melting points for Ti, Al, and TiAl. However, the surface tensions from the model consistently underestimated experimental values. Liquid TiAl's surface was found to be mostly covered with Al atoms, showing that Al has a significant propensity for the liquid/air interface.
JJ Stent Removal under Ultrasound Guidance in Women: It is Simple and Safe.
Amer, Bernard; Gupta, Sandeep; Kanwar, Vijayendra S; Lodh, Bijit; Khumukcham, Somarendra; Akoijam, Kaku Singh
2014-12-01
With the increase in number of patients treated for urological problems with endoscopic procedures, the number of patients with JJ stent is also increasing. The amount of workload thus incurred multiplies, even to the point that, sometimes we waste more time in the operating room removing JJ stents than the actual endourological procedures. Here in our institute, we have devised a very simple and effective way of removing JJ stents in women and also determined the efficacy, safety and cost of JJ stent removal under ultrasound guidance in women in comparison to cystoscopic removal. Two hundred women attending the Department of Urology from July 2012 to July 2013 at RIMS hospital were randomly divided into two arms. One hundred women had their JJ stent removed with cystoscope and another 100 women had their JJ stent removed under ultrasound guidance using simple surgical tools available at the hospital. The primary comparative points were waiting time for operating room appointment date, cost of the procedure, time taken for the procedure, discomfort or pain felt by the patient and urethral injuries. In all the parameters, stent removal under ultrasound guidance was significantly better except for urethral injuries where both the procedures had similar outcomes. We concluded that JJ stent removal under ultrasound guidance in women was simple, effective and safe.
Isolating the Effects of Training Using Simple Regression Analysis: An Example of the Procedure.
ERIC Educational Resources Information Center
Waugh, C. Keith
This paper provides a case example of simple regression analysis, a forecasting procedure used to isolate the effects of training from an identified extraneous variable. This case example focuses on results of a three-day sales training program to improve bank loan officers' knowledge, skill-level, and attitude regarding solicitation and sale of…
Pickl, Karin E; Adamek, Viktor; Gorges, Roland; Sinner, Frank M
2011-07-15
Due to increased regulatory requirements, the interaction of active pharmaceutical ingredients with various surfaces and solutions during production and storage is gaining interest in the pharmaceutical research field, in particular with respect to development of new formulations, new packaging material and the evaluation of cleaning processes. Experimental adsorption/absorption studies as well as the study of cleaning processes require sophisticated analytical methods with high sensitivity for the drug of interest. In the case of 2,6-diisopropylphenol - a small lipophilic drug which is typically formulated as lipid emulsion for intravenous injection - a highly sensitive method in the concentration range of μg/l suitable to be applied to a variety of different sample matrices including lipid emulsions is needed. We hereby present a headspace-solid phase microextraction (HS-SPME) approach as a simple cleanup procedure for sensitive 2,6-diisopropylphenol quantification from diverse matrices choosing a lipid emulsion as the most challenging matrix with regard to complexity. By combining the simple and straight forward HS-SPME sample pretreatment with an optimized GC-MS quantification method a robust and sensitive method for 2,6-diisopropylphenol was developed. This method shows excellent sensitivity in the low μg/l concentration range (5-200μg/l), good accuracy (94.8-98.8%) and precision (intraday-precision 0.1-9.2%, inter-day precision 2.0-7.7%). The method can be easily adapted to other, less complex, matrices such as water or swab extracts. Hence, the presented method holds the potential to serve as a single and simple analytical procedure for 2,6-diisopropylphenol analysis in various types of samples such as required in, e.g. adsorption/absorption studies which typically deal with a variety of different surfaces (steel, plastic, glass, etc.) and solutions/matrices including lipid emulsions. Copyright © 2011 Elsevier B.V. All rights reserved.
New coherent laser communication detection scheme based on channel-switching method.
Liu, Fuchuan; Sun, Jianfeng; Ma, Xiaoping; Hou, Peipei; Cai, Guangyu; Sun, Zhiwei; Lu, Zhiyong; Liu, Liren
2015-04-01
A new coherent laser communication detection scheme based on the channel-switching method is proposed. The detection front end of this scheme comprises a 90° optical hybrid and two balanced photodetectors which outputs the in-phase (I) channel and quadrature-phase (Q) channel signal current, respectively. With this method, the ultrahigh speed analog/digital transform of the signal of the I or Q channel is not required. The phase error between the signal and local lasers is obtained by simple analog circuit. Using the phase error signal, the signals of the I/Q channel are switched alternately. The principle of this detection scheme is presented. Moreover, the comparison of the sensitivity of this scheme with that of homodyne detection with an optical phase-locked loop is discussed. An experimental setup was constructed to verify the proposed detection scheme. The offline processing procedure and results are presented. This scheme could be realized through simple structure and has potential applications in cost-effective high-speed laser communication.
Impulse-variability theory: implications for ballistic, multijoint motor skill performance.
Urbin, M A; Stodden, David F; Fischman, Mark G; Weimar, Wendi H
2011-01-01
Impulse-variability theory (R. A. Schmidt, H. N. Zelaznik, B. Hawkins, J. S. Frank, & J. T. Quinn, 1979) accounts for the curvilinear relationship between the magnitude and resulting variability of the muscular forces that influence the success of goal-directed limb movements. The historical roots of impulse-variability theory are reviewed in the 1st part of this article, including the relationship between movement speed and spatial error. The authors then address the relevance of impulse-variability theory for the control of ballistic, multijoint skills, such as throwing, striking, and kicking. These types of skills provide a stark contrast to the relatively simple, minimal degrees of freedom movements that characterized early research. However, the inherent demand for ballistic force generation is a strong parallel between these simple laboratory tasks and multijoint motor skills. Therefore, the authors conclude by recommending experimental procedures for evaluating the adequacy of impulse variability as a theoretical model within the context of ballistic, multijoint motor skill performance. Copyright © Taylor & Francis Group, LLC
NASA Astrophysics Data System (ADS)
Zhang, Yanjun; Jiang, Li; Wang, Chunru
2015-07-01
A porous Sn@C nanocomposite was prepared via a facile hydrothermal method combined with a simple post-calcination process, using stannous octoate as the Sn source and glucose as the C source. The as-prepared Sn@C nanocomposite exhibited excellent electrochemical behavior with a high reversible capacity, long cycle life and good rate capability when used as an anode material for lithium ion batteries.A porous Sn@C nanocomposite was prepared via a facile hydrothermal method combined with a simple post-calcination process, using stannous octoate as the Sn source and glucose as the C source. The as-prepared Sn@C nanocomposite exhibited excellent electrochemical behavior with a high reversible capacity, long cycle life and good rate capability when used as an anode material for lithium ion batteries. Electronic supplementary information (ESI) available: Detailed experimental procedure and additional characterization, including a Raman spectrum, TGA curve, N2 adsorption-desorption isotherm, TEM images and SEM images. See DOI: 10.1039/c5nr03093e
76 FR 56263 - Titles II and XVI: Documenting and Evaluating Disability in Young Adults
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-12
... carrying out simple instructions and work procedures during a school-sponsored work experience; Difficulty... instructions; Make simple work-related judgments typically required for unskilled work; Respond appropriately... ability to hear and understand simple oral messages, including instructions, and to communicate simple...
Realistic absorption coefficient of ultrathin films
NASA Astrophysics Data System (ADS)
Cesaria, M.; Caricato, A. P.; Martino, M.
2012-10-01
Both a theoretical algorithm and an experimental procedure are discussed of a new route to determine the absorption/scattering properties of thin films deposited on transparent substrates. Notably, the non-measurable contribution of the film-substrate interface is inherently accounted for. While the experimental procedure exploits only measurable spectra combined according to a very simple algorithm, the theoretical derivation does not require numerical handling of the acquired spectra or any assumption on the film homogeneity and substrate thickness. The film absorption response is estimated by subtracting the measured absorption spectrum of the bare substrate from that of the film on the substrate structure but in a non-straightforward way. In fact, an assumption about the absorption profile of the overall structure is introduced and a corrective factor accounting for the relative film-to-substrate thickness. The method is tested on films of a well known material (ITO) as a function of the film structural quality and influence of the film-substrate interface, both deliberately changed by thickness tuning and doping. Results are found fully consistent with information obtained by standard optical analysis and band gap values reported in the literature. Additionally, comparison with a conventional method demonstrates that our route is generally more accurate even if particularly suited for very thin films.
Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld
2013-01-01
Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940
Analysis of pre-service physics teacher skills designing simple physics experiments based technology
NASA Astrophysics Data System (ADS)
Susilawati; Huda, C.; Kurniawan, W.; Masturi; Khoiri, N.
2018-03-01
Pre-service physics teacher skill in designing simple experiment set is very important in adding understanding of student concept and practicing scientific skill in laboratory. This study describes the skills of physics students in designing simple experiments based technologicall. The experimental design stages include simple tool design and sensor modification. The research method used is descriptive method with the number of research samples 25 students and 5 variations of simple physics experimental design. Based on the results of interviews and observations obtained the results of pre-service physics teacher skill analysis in designing simple experimental physics charged technology is good. Based on observation result, pre-service physics teacher skill in designing simple experiment is good while modification and sensor application are still not good. This suggests that pre-service physics teacher still need a lot of practice and do experiments in designing physics experiments using sensor modifications. Based on the interview result, it is found that students have high enough motivation to perform laboratory activities actively and students have high curiosity to be skilled at making simple practicum tool for physics experiment.
Tsuchida, Keiichi; García-García, Héctor M; van der Giessen, Willem J; McFadden, Eugène P; van der Ent, Martin; Sianos, Georgios; Meulenbrug, Hans; Ong, Andrew T L; Serruys, Patrick W
2006-03-01
The objective of this study was to investigate the efficacy of guidewire navigation across coronary artery stenoses using magnetic navigation system (MNS) versus conventional navigation. The MNS is a novel option to facilitate access to target lesions, particularly in tortuous vessels. In an experimental study using a challenging vessel phantom, magnetic-navigated guidewire passage has been reported to reduce fluoroscopy and procedure time significantly. Both magnetic and manual guidewire navigation were attempted in 21 consecutive diseased coronary arteries. The study endpoint was defined as an intraluminal wire position distal to the stenosis. Procedural success was defined as successful guidewire passage without procedural events. Procedure time, amount of contrast, fluoroscopy time, and radiation dose/area product (DAP) were evaluated. There were no procedural events related to either guidewire. Although the lesions attempted had relatively simple and straightforward characteristics, significantly shorter procedure and fluoroscopy time were observed for manual guidewire navigation compared to MNS (median, 40 vs. 120 sec, P=0.001; 38 vs. 105 sec, P=0.001, respectively). Contrast amount and DAP were higher in MNS than in conventional method (median, 13 vs. 9 ml, P=0.018; 215 vs. 73 Gym2, P=0.002, respectively). The magnetic wire did not cross in two vessels. Guidewire navigation using MNS presented a novel, safe, and feasible approach to address coronary artery lesions. Clinical studies are needed to evaluate the potential benefit of the MNS in more complex coronary lesions and tortuous anatomy. Copyright (c) 2006 Wiley-Liss, Inc.
A comparison of methods for teaching receptive labeling to children with autism spectrum disorders.
Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N
2011-01-01
Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed.
Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael
2015-01-01
MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators - attending (AR) and resident radiologists (RR) as well as medical students (MS) - performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were significant differences in experimental procedure times but not in the number of successful biopsies.
NASA Astrophysics Data System (ADS)
Saupe, Florian; Knoblach, Andreas
2015-02-01
Two different approaches for the determination of frequency response functions (FRFs) are used for the non-parametric closed loop identification of a flexible joint industrial manipulator with serial kinematics. The two applied experiment designs are based on low power multisine and high power chirp excitations. The main challenge is to eliminate disturbances of the FRF estimates caused by the numerous nonlinearities of the robot. For the experiment design based on chirp excitations, a simple iterative procedure is proposed which allows exploiting the good crest factor of chirp signals in a closed loop setup. An interesting synergy of the two approaches, beyond validation purposes, is pointed out.
Properties of nanocrystalline Si layers embedded in structure of solar cell
NASA Astrophysics Data System (ADS)
Jurečka, Stanislav; Imamura, Kentaro; Matsumoto, Taketoshi; Kobayashi, Hikaru
2017-12-01
Suppression of spectral reflectance from the surface of solar cell is necessary for achieving a high energy conversion efficiency. We developed a simple method for forming nanocrystalline layers with ultralow reflectance in a broad range of wavelengths. The method is based on metal assisted etching of the silicon surface. In this work, we prepared Si solar cell structures with embedded nanocrystalline layers. The microstructure of embedded layer depends on the etching conditions. We examined the microstructure of the etched layers by a transmission electron microscope and analysed the experimental images by statistical and Fourier methods. The obtained results provide information on the applied treatment operations and can be used to optimize the solar cell forming procedure.
Squids in the Study of Cerebral Magnetic Field
NASA Astrophysics Data System (ADS)
Romani, G. L.; Narici, L.
The following sections are included: * INTRODUCTION * HISTORICAL OVERVIEW * NEUROMAGNETIC FIELDS AND AMBIENT NOISE * DETECTORS * Room temperature sensors * SQUIDs * DETECTION COILS * Magnetometers * Gradiometers * Balancing * Planar gradiometers * Choice of the gradiometer parameters * MODELING * Current pattern due to neural excitations * Action potentials and postsynaptic currents * The current dipole model * Neural population and detected fields * Spherically bounded medium * SPATIAL CONFIGURATION OF THE SENSORS * SOURCE LOCALIZATION * Localization procedure * Experimental accuracy and reproducibility * SIGNAL PROCESSING * Analog Filtering * Bandpass filters * Line rejection filters * DATA ANALYSIS * Analysis of evoked/event-related responses * Simple average * Selected average * Recursive techniques * Similarity analysis * Analysis of spontaneous activity * Mapping and localization * EXAMPLES OF NEUROMAGNETIC STUDIES * Neuromagnetic measurements * Studies on the normal brain * Clinical applications * Epilepsy * Tinnitus * CONCLUSIONS * ACKNOWLEDGEMENTS * REFERENCES
Robust matching for voice recognition
NASA Astrophysics Data System (ADS)
Higgins, Alan; Bahler, L.; Porter, J.; Blais, P.
1994-10-01
This paper describes an automated method of comparing a voice sample of an unknown individual with samples from known speakers in order to establish or verify the individual's identity. The method is based on a statistical pattern matching approach that employs a simple training procedure, requires no human intervention (transcription, work or phonetic marketing, etc.), and makes no assumptions regarding the expected form of the statistical distributions of the observations. The content of the speech material (vocabulary, grammar, etc.) is not assumed to be constrained in any way. An algorithm is described which incorporates frame pruning and channel equalization processes designed to achieve robust performance with reasonable computational resources. An experimental implementation demonstrating the feasibility of the concept is described.
Statistical theory of chromatography: new outlooks for affinity chromatography.
Denizot, F C; Delaage, M A
1975-01-01
We have developed further the statistical approach to chromatography initiated by Giddings and Eyring, and applied it to affinity chromatography. By means of a convenient expression of moments the convergence towards the Laplace-Gauss distribution has been established. The Gaussian character is not preserved if other causes of dispersion are taken into account, but expressions of moments can be obtained in a generalized form. A simple procedure is deduced for expressing the fundamental constants of the model in terms of purely experimental quantities. Thus, affinity chromatography can be used to determine rate constants of association and dissociation in a range considered as the domain of the stopped-flow methods. PMID:1061072
Ötvös, Sándor B; Mándity, István M; Fülöp, Ferenc
2011-08-01
A simple and efficient flow-based technique is reported for the catalytic deuteration of several model nitrogen-containing heterocyclic compounds which are important building blocks of pharmacologically active materials. A continuous flow reactor was used in combination with on-demand pressure-controlled electrolytic D(2) production. The D(2) source was D(2)O, the consumption of which was very low. The experimental set-up allows the fine-tuning of pressure, temperature, and flow rate so as to determine the optimal conditions for the deuteration reactions. The described procedure lacks most of the drawbacks of the conventional batch deuteration techniques, and additionally is highly selective and reproducible.
2011-01-01
Summary A simple, efficient, and mild procedure for a solvent-free one-step synthesis of various 4,4′-diaminotriarylmethane derivatives in the presence of antimony trichloride as catalyst is described. Triarylmethane derivatives were prepared in good to excellent yields and characterized by elemental analysis, FTIR, 1H and 13C NMR spectroscopic techniques. The structural and vibrational analysis were investigated by performing theoretical calculations at the HF and DFT levels of theory by standard 6-31G*, 6-31G*/B3LYP, and B3LYP/cc-pVDZ methods and good agreement was obtained between experimental and theoretical results. PMID:21445373
The Capillary Flow Experiments Aboard the International Space Station: Increments 9-15
NASA Technical Reports Server (NTRS)
Jenson, Ryan M.; Weislogel, Mark M.; Tavan, Noel T.; Chen, Yongkang; Semerjian, Ben; Bunnell, Charles T.; Collicott, Steven H.; Klatte, Jorg; dreyer, Michael E.
2009-01-01
This report provides a summary of the experimental, analytical, and numerical results of the Capillary Flow Experiment (CFE) performed aboard the International Space Station (ISS). The experiments were conducted in space beginning with Increment 9 through Increment 16, beginning August 2004 and ending December 2007. Both primary and extra science experiments were conducted during 19 operations performed by 7 astronauts including: M. Fincke, W. McArthur, J. Williams, S. Williams, M. Lopez-Alegria, C. Anderson, and P. Whitson. CFE consists of 6 approximately 1 to 2 kg handheld experiment units designed to investigate a selection of capillary phenomena of fundamental and applied importance, such as large length scale contact line dynamics (CFE-Contact Line), critical wetting in discontinuous structures (CFE-Vane Gap), and capillary flows and passive phase separations in complex containers (CFE-Interior Corner Flow). Highly quantitative video from the simply performed flight experiments provide data helpful in benchmarking numerical methods, confirming theoretical models, and guiding new model development. In an extensive executive summary, a brief history of the experiment is reviewed before introducing the science investigated. A selection of experimental results and comparisons with both analytic and numerical predictions is given. The subsequent chapters provide additional details of the experimental and analytical methods developed and employed. These include current presentations of the state of the data reduction which we anticipate will continue throughout the year and culminate in several more publications. An extensive appendix is used to provide support material such as an experiment history, dissemination items to date (CFE publication, etc.), detailed design drawings, and crew procedures. Despite the simple nature of the experiments and procedures, many of the experimental results may be practically employed to enhance the design of spacecraft engineering systems involving capillary interface dynamics.
Morishita, Keitaro; Hiramoto, Akira; Michishita, Asuka; Takagi, Satoshi; Hoshino, Yuki; Itami, Takaharu; Lim, Sue Yee; Osuga, Tatsuyuki; Nakamura, Sayuri; Ochiai, Kenji; Nakamura, Kensuke; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi
2017-04-01
OBJECTIVE To assess the use of contrast-enhanced ultrasonography (CEUS) of the hepatic vein for the detection of hemodynamic changes associated with experimentally induced portal hypertension in dogs. ANIMALS 6 healthy Beagles. PROCEDURES A prospective study was conducted. A catheter was surgically placed in the portal vein of each dog. Hypertension was induced by intraportal injection of microspheres (10 to 15 mg/kg) at 5-day intervals via the catheter. Microsphere injections were continued until multiple acquired portosystemic shunts were created. Portal vein pressure (PVP) was measured through the catheter. Contrast-enhanced ultrasonography was performed before and after establishment of hypertension. Time-intensity curves were generated from the region of interest in the hepatic vein. Perfusion variables measured for statistical analysis were hepatic vein arrival time, time to peak, time to peak phase (TTPP), and washout ratio. The correlation between CEUS variables and PVP was assessed by use of simple regression analysis. RESULTS Time to peak and TTPP were significantly less after induction of portal hypertension. Simple regression analysis revealed a significant negative correlation between TTPP and PVP. CONCLUSIONS AND CLINICAL RELEVANCE CEUS was useful for detecting hemodynamic changes associated with experimentally induced portal hypertension in dogs, which was characterized by a rapid increase in the intensity of the hepatic vein. Furthermore, TTPP, a time-dependent variable, provided useful complementary information for predicting portal hypertension. IMPACT FOR HUMAN MEDICINE Because the method described here induced presinusoidal portal hypertension, these results can be applied to idiopathic portal hypertension in humans.
ERIC Educational Resources Information Center
Dias, Alice M.; Ferreira, Maria La Salete
2015-01-01
A simple and ecofriendly procedure was developed in order to prepare extracts from red and green leaves. This procedure enables the separation of yellow, green, and red band pigments and optimizes the previously reported baking soda "supermarket column". The same extract also led to a novel and colorful potato starch column, which can…
A Constrained Genetic Algorithm with Adaptively Defined Fitness Function in MRS Quantification
NASA Astrophysics Data System (ADS)
Papakostas, G. A.; Karras, D. A.; Mertzios, B. G.; Graveron-Demilly, D.; van Ormondt, D.
MRS Signal quantification is a rather involved procedure and has attracted the interest of the medical engineering community, regarding the development of computationally efficient methodologies. Significant contributions based on Computational Intelligence tools, such as Neural Networks (NNs), demonstrated a good performance but not without drawbacks already discussed by the authors. On the other hand preliminary application of Genetic Algorithms (GA) has already been reported in the literature by the authors regarding the peak detection problem encountered in MRS quantification using the Voigt line shape model. This paper investigates a novel constrained genetic algorithm involving a generic and adaptively defined fitness function which extends the simple genetic algorithm methodology in case of noisy signals. The applicability of this new algorithm is scrutinized through experimentation in artificial MRS signals interleaved with noise, regarding its signal fitting capabilities. Although extensive experiments with real world MRS signals are necessary, the herein shown performance illustrates the method's potential to be established as a generic MRS metabolites quantification procedure.
Stability of Polymer Ultrathin Films (<7 nm) Made by a Top-Down Approach.
Bal, Jayanta Kumar; Beuvier, Thomas; Unni, Aparna Beena; Chavez Panduro, Elvia Anabela; Vignaud, Guillaume; Delorme, Nicolas; Chebil, Mohamed Souheib; Grohens, Yves; Gibaud, Alain
2015-08-25
In polymer physics, the dewetting of spin-coated polystyrene ultrathin films on silicon remains mysterious. By adopting a simple top-down method based on good solvent rinsing, we are able to prepare flat polystyrene films with a controlled thickness ranging from 1.3 to 7.0 nm. Their stability was scrutinized after a classical annealing procedure above the glass transition temperature. Films were found to be stable on oxide-free silicon irrespective of film thickness, while they were unstable (<2.9 nm) and metastable (>2.9 nm) on 2 nm oxide-covered silicon substrates. The Lifshitz-van der Waals intermolecular theory that predicts the domains of stability as a function of the film thickness and of the substrate nature is now fully reconciled with our experimental observations. We surmise that this reconciliation is due to the good solvent rinsing procedure that removes the residual stress and/or the density variation of the polystyrene films inhibiting thermodynamically the dewetting on oxide-free silicon.
Coherent X-ray beam metrology using 2D high-resolution Fresnel-diffraction analysis.
Ruiz-Lopez, M; Faenov, A; Pikuz, T; Ozaki, N; Mitrofanov, A; Albertazzi, B; Hartley, N; Matsuoka, T; Ochante, Y; Tange, Y; Yabuuchi, T; Habara, T; Tanaka, K A; Inubushi, Y; Yabashi, M; Nishikino, M; Kawachi, T; Pikuz, S; Ishikawa, T; Kodama, R; Bleiner, D
2017-01-01
Direct metrology of coherent short-wavelength beamlines is important for obtaining operational beam characteristics at the experimental site. However, since beam-time limitation imposes fast metrology procedures, a multi-parametric metrology from as low as a single shot is desirable. Here a two-dimensional (2D) procedure based on high-resolution Fresnel diffraction analysis is discussed and applied, which allowed an efficient and detailed beamline characterization at the SACLA XFEL. So far, the potential of Fresnel diffraction for beamline metrology has not been fully exploited because its high-frequency fringes could be only partly resolved with ordinary pixel-limited detectors. Using the high-spatial-frequency imaging capability of an irradiated LiF crystal, 2D information of the coherence degree, beam divergence and beam quality factor M 2 were retrieved from simple diffraction patterns. The developed beam metrology was validated with a laboratory reference laser, and then successfully applied at a beamline facility, in agreement with the source specifications.
Note: a simple experimental arrangement to generate optical vortex beams.
Kumar, Dhirendra; Das, Abhijit; Boruah, Bosanta R
2013-02-01
In this Note, we present a simple experimental arrangement to generate optical vortex beams. We have demonstrated how by taking print of an interferogram on a transparent sheet, vortex beams with various topological charges can be generated. Experimental results show that the vortex beam indeed carries the topological charge that is used to compute the interferograms. In addition to being simple and inexpensive, one major advantage of the arrangement is that it makes it possible to generate different vortex beams quickly, unlike using the photographic process to create the holograms.
Martijn, Carolien; Vanderlinden, Marlies; Roefs, Anne; Huijding, Jorg; Jansen, Anita
2010-09-01
Many women show weight and body concerns that leave them vulnerable to body dissatisfaction, lowered self-esteem, psychological distress, and eating disorders. This study tested whether body satisfaction could be increased by means of evaluative conditioning. In the experimental condition (n = 26), women with low and high body concern completed a conditioning procedure in which pictures of their bodies were selectively linked to positive social stimuli (pictures of smiling faces). Pictures of control bodies were linked to neutral or negative social stimuli (neutral and frowning faces). In a control condition (n = 28), low and high body concerned women underwent a procedure in which pictures of their own body and of control bodies were randomly followed by positive, neutral, and negative social stimuli. Changes in body satisfaction and self-esteem before and after the conditioning task. Women with high body concern demonstrated an increase in body satisfaction and global self-esteem when pictorial representations of their own bodies were associated with positive stimuli that signaled social acceptance. A simple conditioning procedure increased body satisfaction in healthy, normal weight women who were concerned about their shape and weight. (PsycINFO Database Record (c) 2010 APA, all rights reserved).
Operator priming and generalization of practice in adults' simple arithmetic.
Chen, Yalin; Campbell, Jamie I D
2016-04-01
There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication, suggesting that a general addition procedure was primed by the + sign. In Experiment 1 (n = 36), we applied this operator-priming paradigm to rule-based problems (0 + N = N, 1 × N = N, 0 × N = 0) and 1 + N problems with N ranging from 0 to 9. For the rule-based problems, we found both operator-preview facilitation and generalization of practice (e.g., practicing 0 + 3 sped up unpracticed 0 + 8), the latter being a signature of procedure use; however, we also found operator-preview facilitation for 1 + N in the absence of generalization, which implies the 1 + N problems were solved by fact retrieval but nonetheless were facilitated by an operator preview. Thus, the operator preview effect does not discriminate procedure use from fact retrieval. Experiment 2 (n = 36) investigated whether a population with advanced mathematical training-engineering and computer science students-would show generalization of practice for nonrule-based simple addition problems (e.g., 1 + 4, 4 + 7). The 0 + N problems again presented generalization, whereas no nonzero problem type did; but all nonzero problems sped up when the identical problems were retested, as predicted by item-specific fact retrieval. The results pose a strong challenge to the generality of the proposal that skilled adults' simple addition is based on fast procedural algorithms, and instead support a fact-retrieval model of fast addition performance. (c) 2016 APA, all rights reserved).
A computerized stroop test for the evaluation of psychotropic drugs in healthy participants.
Pilli, Raveendranadh; Naidu, Mur; Pingali, Usha Rani; Shobha, J C; Reddy, A Praveen
2013-04-01
The Stroop paradigm evaluates susceptibility to interference and is sensitive to dysfunction in frontal lobes and drug effects. The aim of the present study was to establish a simple and reliable computerized version of Stroop color-word test, which can be used for screening of various psychotropic drugs. The standardized method was followed in all cases, by recording the reaction time (RT) in msec in 24 healthy participants using computerized version of Stroop color-word test. Reproducibility of the test procedure was evaluated by recording the RTs by a single experimenter on two sessions (interday reproducibility). Validity of the model was further tested by evaluating the psychotropic effect of Zolpidem 5 mg, Caffeine 500 mg, or Placebo on 24 healthy subjects in a randomized, double blind three-way crossover design. The method was found to produce low variability with coefficient of variation less than 10%. Interday reproducibility was very good as shown by Bland-Altman plot with most of the values within ±2SD. There was a significant increase in RTs in Stroop performance with Zolpidem at 1 hr and 2 hrs; in contrast, caffeine significantly decreased RTs in Stroop performance at 1 hr only compared to placebo. The Stroop color-word recording and analysis system is simple, sensitive to centrally acting drug effects, and has potential for future experimental psychomotor assessment studies.
A simple method to separate red wine nonpolymeric and polymeric phenols by solid-phase extraction.
Pinelo, Manuel; Laurie, V Felipe; Waterhouse, Andrew L
2006-04-19
Simple polyphenols and tannins differ in the way that they contribute to the organoleptic profile of wine and their effects on human health. Very few straightforward techniques to separate red wine nonpolymeric phenols from the polymeric fraction are available in the literature. In general, they are complex, time-consuming, and generate large amounts of waste. In this procedure, the separation of these compounds was achieved using C18 cartridges, three solvents with different elution strengths, and pH adjustments of the experimental matrices. Two full factorial 2(3) experimental designs were performed to find the optimal critical variables and their values, allowing for the maximization of tannin recovery and separation efficiency (SE). Nonpolymeric phenols such as phenolic acids, monomers, and oligomers of flavonol and flavan-3-ols and anthocyanins were removed from the column by means of an aqueous solvent followed by ethyl acetate. The polymeric fraction was then eluted with a combination of methanol/acetone/water. The best results were attained with 1 mL of wine sample, a 10% methanol/water solution (first eluant), ethyl acetate (second eluant), and 66% acetone/water as the polymeric phenols-eluting solution (third eluant), obtaining a SE of ca. 90%. Trials with this method on fruit juices also showed high separation efficiency. Hence, this solid-phase extraction method has been shown to be a simple and efficient alternative for the separation of nonpolymeric phenolic fractions and the polymeric ones, and this method could have important applications to sample purification prior to biological testing due to the nonspecific binding of polymeric phenolics to nearly all enzymes and receptor sites.
5 CFR 9701.521 - Grievance procedures.
Code of Federal Regulations, 2010 CFR
2010-01-01
... paragraphs (d), (f), and (g) of this section, the procedures must be the exclusive administrative procedures... simple, provide for expeditious processing, and include procedures that— (i) Assure an exclusive representative the right, in its own behalf or on behalf of any employee in the unit represented by the exclusive...
ERIC Educational Resources Information Center
Smyth, Sinead; Barnes-Holmes, Dermot; Forsyth, John P.
2006-01-01
Two experiments investigated the derived transfer of functions through equivalence relations established using a stimulus pairing observation procedure. In Experiment 1, participants were trained on a simple discrimination (A1+/A2-) and then a stimulus pairing observation procedure was used to establish 4 stimulus pairings (A1-B1, A2-B2, B1-C1,…
Ganger, Michael T; Dietz, Geoffrey D; Ewing, Sarah J
2017-12-01
qPCR has established itself as the technique of choice for the quantification of gene expression. Procedures for conducting qPCR have received significant attention; however, more rigorous approaches to the statistical analysis of qPCR data are needed. Here we develop a mathematical model, termed the Common Base Method, for analysis of qPCR data based on threshold cycle values (C q ) and efficiencies of reactions (E). The Common Base Method keeps all calculations in the logscale as long as possible by working with log 10 (E) ∙ C q , which we call the efficiency-weighted C q value; subsequent statistical analyses are then applied in the logscale. We show how efficiency-weighted C q values may be analyzed using a simple paired or unpaired experimental design and develop blocking methods to help reduce unexplained variation. The Common Base Method has several advantages. It allows for the incorporation of well-specific efficiencies and multiple reference genes. The method does not necessitate the pairing of samples that must be performed using traditional analysis methods in order to calculate relative expression ratios. Our method is also simple enough to be implemented in any spreadsheet or statistical software without additional scripts or proprietary components.
The Simple Lamb Wave Analysis to Characterize Concrete Wide Beams by the Practical MASW Test
Lee, Young Hak; Oh, Taekeun
2016-01-01
In recent years, the Lamb wave analysis by the multi-channel analysis of surface waves (MASW) for concrete structures has been an effective nondestructive evaluation, such as the condition assessment and dimension identification by the elastic wave velocities and their reflections from boundaries. This study proposes an effective Lamb wave analysis by the practical application of MASW to concrete wide beams in an easy and simple manner in order to identify the dimension and elastic wave velocity (R-wave) for the condition assessment (e.g., the estimation of elastic properties). This is done by identifying the zero-order antisymmetric (A0) and first-order symmetric (S1) modes among multimodal Lamb waves. The MASW data were collected on eight concrete wide beams and compared to the actual depth and to the pressure (P-) wave velocities collected for the same specimen. Information is extracted from multimodal Lamb wave dispersion curves to obtain the elastic stiffness parameters and the thickness of the concrete structures. Due to the simple and cost-effective procedure associated with the MASW processing technique, the characteristics of several fundamental modes in the experimental Lamb wave dispersion curves could be measured. Available reference data are in good agreement with the parameters that were determined by our analysis scheme. PMID:28773562
DOE Office of Scientific and Technical Information (OSTI.GOV)
Figueroa, C.; Brizuela, H.; Heluani, S. P.
2014-05-21
The backscattering coefficient is a magnitude whose measurement is fundamental for the characterization of materials with techniques that make use of particle beams and particularly when performing microanalysis. In this work, we report the results of an analytic method to calculate the backscattering and absorption coefficients of electrons in similar conditions to those of electron probe microanalysis. Starting on a five level states ladder model in 3D, we deduced a set of integro-differential coupled equations of the coefficients with a method know as invariant embedding. By means of a procedure proposed by authors, called method of convergence, two types ofmore » approximate solutions for the set of equations, namely complete and simple solutions, can be obtained. Although the simple solutions were initially proposed as auxiliary forms to solve higher rank equations, they turned out to be also useful for the estimation of the aforementioned coefficients. In previous reports, we have presented results obtained with the complete solutions. In this paper, we present results obtained with the simple solutions of the coefficients, which exhibit a good degree of fit with the experimental data. Both the model and the calculation method presented here can be generalized to other techniques that make use of different sorts of particle beams.« less
Teaching a Generalizable Language Strategy.
ERIC Educational Resources Information Center
Foxx, R. M.; And Others
This paper describes the development and use of language training procedures, referred to as cues-pause-point procedures, that rely on behavioral principles and simple and natural teaching procedures and that are exhibited in many normal parent-child or teacher-student verbal interactions. The procedures have been effective in teaching severely…
Saito, Masatoshi; Sagara, Shota
2017-06-01
The main objective of this study is to propose a simple formulation (which we called DEEDZ) for deriving effective atomic numbers (Z eff ) via electron density (ρ e ) calibration from dual-energy (DE) CT data. We carried out numerical analysis of this DEEDZ method for a large variety of materials with known elemental compositions and mass densities using an available photon cross sections database. The new conversion approach was also applied to previously published experimental DECT data to validate its practical feasibility. We performed numerical analysis of the DEEDZ conversion method for tissue surrogates that have the same chemical compositions and mass densities as a commercial tissue-characterization phantom in order to determine the parameters necessary for the ρ e and Z eff calibrations in the DEEDZ conversion. These parameters were then applied to the human-body-equivalent tissues of ICRU Report 46 as objects of interest with unknown ρ e and Z eff . The attenuation coefficients of these materials were calculated using the XCOM photon cross sections database. We also applied the DEEDZ conversion to experimental DECT data available in the literature, which was measured for two commercial phantoms of different shapes and sizes using a dual-source CT scanner at 80 kV and 140 kV/Sn. The simulated Z eff 's were in excellent agreement with the reference values for almost all of the ICRU-46 human tissues over the Z eff range from 5.83 (gallstones-cholesterol) to 16.11 (bone mineral-hydroxyapatite). The relative deviations from the reference Z eff were within ± 0.3% for all materials, except for one outlier that presented a -3.1% deviation, namely, the thyroid. The reason for this discrepancy is that the thyroid contains a small amount of iodine, an element with a large atomic number (Z = 53). In the experimental case, we confirmed that the simple formulation with less fit parameters enable to calibrate Z eff as accurately as the existing calibration procedure. The DEEDZ conversion method based on the simple formulation proposed could facilitate the construction of ρ e and Z eff images from acquired DECT data. © 2017 American Association of Physicists in Medicine.
A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.
John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192).
We have developed a simple, mild extraction procedure using methanol which, when...
A COMPARISON OF METHODS FOR TEACHING RECEPTIVE LABELING TO CHILDREN WITH AUTISM SPECTRUM DISORDERS
Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N
2011-01-01
Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed. PMID:21941380
NASA Astrophysics Data System (ADS)
Cherubini, Antonello; Moretti, Giacomo; Vertechy, Rocco; Fontana, Marco
2015-06-01
The discovery of an innovative class of thermally activated actuators based on twisted polymeric fibres has opened new horizons toward the development of effective devices that can be easily manufactured using inexpensive materials such as fishing lines or sewing threads. These new devices show large deformations when heated together with promising performance in terms of energy and power densities. With the aim of providing information and data useful for the future engineering applications, we present the results of a thermo-mechanical characterization conducted on a specific type of twisted polymeric fibre (i.e. nylon-made coiled actuators) that is considered particularly promising. A custom experimental test-bench and procedure have been developed and employed to run isothermal and isometric tensile tests on a set of specimens that are fabricated with a simple and repeatable process. The results of the experiments highlight some important issues related to the response of these actuators such as hysteresis, repeatability, predictability and stored elastic energy.
Measurement of M²-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor.
Du, Yongzhao
2016-11-29
For asymmetric laser beams, the values of beam quality factor M x 2 and M y 2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M²-curve is developed. The M²-curve not only contains the beam quality factor M x 2 and M y 2 in the x -direction and y -direction, respectively; but also introduces a curve of M x α 2 versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M²-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts.
Experimental recovery of quantum correlations in absence of system-environment back-action
Xu, Jin-Shi; Sun, Kai; Li, Chuan-Feng; Xu, Xiao-Ye; Guo, Guang-Can; Andersson, Erika; Lo Franco, Rosario; Compagno, Giuseppe
2013-01-01
Revivals of quantum correlations in composite open quantum systems are a useful dynamical feature against detrimental effects of the environment. Their occurrence is attributed to flows of quantum information back and forth from systems to quantum environments. However, revivals also show up in models where the environment is classical, thus unable to store quantum correlations, and forbids system-environment back-action. This phenomenon opens basic issues about its interpretation involving the role of classical environments, memory effects, collective effects and system-environment correlations. Moreover, an experimental realization of back-action-free quantum revivals has applicative relevance as it leads to recover quantum resources without resorting to more demanding structured environments and correction procedures. Here we introduce a simple two-qubit model suitable to address these issues. We then report an all-optical experiment which simulates the model and permits us to recover and control, against decoherence, quantum correlations without back-action. We finally give an interpretation of the phenomenon by establishing the roles of the involved parties. PMID:24287554
Clos, Lawrence J; Jofre, M Fransisca; Ellinger, James J; Westler, William M; Markley, John L
2013-06-01
To facilitate the high-throughput acquisition of nuclear magnetic resonance (NMR) experimental data on large sets of samples, we have developed a simple and straightforward automated methodology that capitalizes on recent advances in Bruker BioSpin NMR spectrometer hardware and software. Given the daunting challenge for non-NMR experts to collect quality spectra, our goal was to increase user accessibility, provide customized functionality, and improve the consistency and reliability of resultant data. This methodology, NMRbot, is encoded in a set of scripts written in the Python programming language accessible within the Bruker BioSpin TopSpin ™ software. NMRbot improves automated data acquisition and offers novel tools for use in optimizing experimental parameters on the fly. This automated procedure has been successfully implemented for investigations in metabolomics, small-molecule library profiling, and protein-ligand titrations on four Bruker BioSpin NMR spectrometers at the National Magnetic Resonance Facility at Madison. The investigators reported benefits from ease of setup, improved spectral quality, convenient customizations, and overall time savings.
Measurement of M2-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
Du, Yongzhao
2016-01-01
For asymmetric laser beams, the values of beam quality factor Mx2 and My2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M2-curve is developed. The M2-curve not only contains the beam quality factor Mx2 and My2 in the x-direction and y-direction, respectively; but also introduces a curve of Mxα2 versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M2-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts. PMID:27916845
Social learning by imitation in a reptile (Pogona vitticeps).
Kis, Anna; Huber, Ludwig; Wilkinson, Anna
2015-01-01
The ability to learn through imitation is thought to be the basis of cultural transmission and was long considered a distinctive characteristic of humans. There is now evidence that both mammals and birds are capable of imitation. However, nothing is known about these abilities in the third amniotic class-reptiles. Here, we use a bidirectional control procedure to show that a reptile species, the bearded dragon (Pogona vitticeps), is capable of social learning that cannot be explained by simple mechanisms such as local enhancement or goal emulation. Subjects in the experimental group opened a trap door to the side that had been demonstrated, while subjects in the ghost control group, who observed the door move without the intervention of a conspecific, were unsuccessful. This, together with differences in behaviour between experimental and control groups, provides compelling evidence that reptiles possess cognitive abilities that are comparable to those observed in mammals and birds and suggests that learning by imitation is likely to be based on ancient mechanisms.
Experimental recovery of quantum correlations in absence of system-environment back-action.
Xu, Jin-Shi; Sun, Kai; Li, Chuan-Feng; Xu, Xiao-Ye; Guo, Guang-Can; Andersson, Erika; Lo Franco, Rosario; Compagno, Giuseppe
2013-01-01
Revivals of quantum correlations in composite open quantum systems are a useful dynamical feature against detrimental effects of the environment. Their occurrence is attributed to flows of quantum information back and forth from systems to quantum environments. However, revivals also show up in models where the environment is classical, thus unable to store quantum correlations, and forbids system-environment back-action. This phenomenon opens basic issues about its interpretation involving the role of classical environments, memory effects, collective effects and system-environment correlations. Moreover, an experimental realization of back-action-free quantum revivals has applicative relevance as it leads to recover quantum resources without resorting to more demanding structured environments and correction procedures. Here we introduce a simple two-qubit model suitable to address these issues. We then report an all-optical experiment which simulates the model and permits us to recover and control, against decoherence, quantum correlations without back-action. We finally give an interpretation of the phenomenon by establishing the roles of the involved parties.
NASA Astrophysics Data System (ADS)
Marcus, P. M.; Jona, F.
2005-05-01
A simple effective procedure (MNP) for finding equilibrium tetragonal and hexagonal states under pressure is described and applied. The MNP procedure finds a path to minima of the Gibbs free energy G at T=0 K (G=E+pV, E=energy per atom, p=pressure, V=volume per atom) for tetragonal and hexagonal structures by using the approximate expansion of G in linear and quadratic strains at an arbitrary initial structure to find a change in the strains which moves toward a minimum of G. Iteration automatically proceeds to a minimum within preset convergence criteria on the calculation of the minimum. Comparison is made with experimental results for the ground states of seven metallic elements in hexagonal close-packed (hcp), face- and body-centered cubic structures, and with a previous procedure for finding minima based on tracing G along the epitaxial Bain path (EBP) to a minimum; the MNP is more easily generalized than the EBP procedure to lower symmetry and more atoms in the unit cell. Comparison is also made with a molecular-dynamics program for crystal equilibrium structures under pressure and with CRYSTAL, a program for crystal equilibrium structures at zero pressure. Application of MNP to the elements Y and Cd, which have hcp ground states at zero pressure, finds minima of E at face-centered cubic (fcc) structure for both Y and Cd. Evaluation of all the elastic constants shows that fcc Y is stable, hence a metastable phase, but fcc Cd is unstable.
Lewis, Debra A; Ding, Yong Hong; Dai, Daying; Kadirvel, Ramanathan; Danielson, Mark A; Cloft, Harry J; Kallmes, David F
2008-01-01
Background and Purpose Elastase-induced aneurysms in rabbits have been proposed as a useful preclinical tool for device development. The object of this study is to report rates of morbidity and mortality associated with creation and embolization of the elastase-induced rabbit aneurysm, and to assess the impact of operator experience on these rates. Methods Elastase-induced model aneurysms were created in New Zealand White rabbits (n=700). One neuroradiologist/investigator, naïve to the aneurysm creation procedure at the outset of the experiments, performed all surgeries. All morbidity and deaths related to aneurysm creation (n=700) and embolization procedures (n=529) were categorized into acute and chronic deaths. Data were analyzed with single regression analysis and ANOVA. To assess the impact of increasing operator experience, the number of animals was broken into 50 animal increments. Results There were 121 (17%) deaths among 700 subjects. Among 700 aneurysm creation procedures, 59 deaths (8.4%) were noted. Among 529 aneurysm embolization procedures, 43 deaths (8.1%) were noted. Nineteen additional deaths (2.7% of 700 subjects) were unrelated to procedures. Simple regression indicated mortality associated with procedures diminished with increasing operator experience (R2=0.38; p=0.0180) and that for each 50 rabbit increment mortality is reduced on average by 0.6 percent. Conclusions Mortality rates of approximately 8% are associated with both experimental aneurysm creation and with embolization in the rabbit, elastase-induced aneurysm model. Increasing operator experience is inversely correlated with mortality and the age of the rabbit is positively associated with morbidity. PMID:19001536
Thors, B; Hansson, B; Törnevik, C
2009-07-07
In this paper, a procedure is proposed for generating simple and practical compliance boundaries for mobile communication base station antennas. The procedure is based on a set of formulae for estimating the specific absorption rate (SAR) in certain directions around a class of common base station antennas. The formulae, given for both whole-body and localized SAR, require as input the frequency, the transmitted power and knowledge of antenna-related parameters such as dimensions, directivity and half-power beamwidths. With knowledge of the SAR in three key directions it is demonstrated how simple and practical compliance boundaries can be generated outside of which the exposure levels do not exceed certain limit values. The conservativeness of the proposed procedure is discussed based on results from numerical radio frequency (RF) exposure simulations with human body phantoms from the recently developed Virtual Family.
A simple Lagrangian forecast system with aviation forecast potential
NASA Technical Reports Server (NTRS)
Petersen, R. A.; Homan, J. H.
1983-01-01
A trajectory forecast procedure is developed which uses geopotential tendency fields obtained from a simple, multiple layer, potential vorticity conservative isentropic model. This model can objectively account for short-term advective changes in the mass field when combined with fine-scale initial analyses. This procedure for producing short-term, upper-tropospheric trajectory forecasts employs a combination of a detailed objective analysis technique, an efficient mass advection model, and a diagnostically proven trajectory algorithm, none of which require extensive computer resources. Results of initial tests are presented, which indicate an exceptionally good agreement for trajectory paths entering the jet stream and passing through an intensifying trough. It is concluded that this technique not only has potential for aiding in route determination, fuel use estimation, and clear air turbulence detection, but also provides an example of the types of short range forecasting procedures which can be applied at local forecast centers using simple algorithms and a minimum of computer resources.
NGA-West 2 GMPE average site coefficients for use in earthquake-resistant design
Borcherdt, Roger D.
2015-01-01
Site coefficients corresponding to those in tables 11.4–1 and 11.4–2 of Minimum Design Loads for Buildings and Other Structures published by the American Society of Civil Engineers (Standard ASCE/SEI 7-10) are derived from four of the Next Generation Attenuation West2 (NGA-W2) Ground-Motion Prediction Equations (GMPEs). The resulting coefficients are compared with those derived by other researchers and those derived from the NGA-West1 database. The derivation of the NGA-W2 average site coefficients provides a simple procedure to update site coefficients with each update in the Maximum Considered Earthquake Response MCER maps. The simple procedure yields average site coefficients consistent with those derived for site-specific design purposes. The NGA-W2 GMPEs provide simple scale factors to reduce conservatism in current simplified design procedures.
A Mechanical Coil Insertion System for Endovascular Coil Embolization of Intracranial Aneurysms
Haraguchi, K.; Miyachi, S.; Matsubara, N.; Nagano, Y.; Yamada, H.; Marui, N.; Sano, A.; Fujimoto, H.; Izumi, T.; Yamanouchi, T.; Asai, T.; Wakabayashi, T.
2013-01-01
Summary Like other fields of medicine, robotics and mechanization might be introduced into endovascular coil embolization of intracranial aneurysms for effective treatment. We have already reported that coil insertion force could be smaller and more stable when the coil delivery wire is driven mechanically at a constant speed. Another background is the difficulty in synchronizing operators' minds and hands when two operators control the microcatheter and the coil respectively. We have therefore developed a mechanical coil insertion system enabling a single operator to insert coils at a fixed speed while controlling the microcatheter. Using our new system, the operator manipulated the microcatheter with both hands and drove the coil using foot switches simultaneously. A delivery wire force sensor previously reported was used concurrently, allowing the operator to detect excessive stress on the wire. In vitro coil embolization was performed using three methods: simple mechanical advance of the coil; simple mechanical advance of the coil with microcatheter control; and driving (forward and backward) of the coil using foot switches in addition to microcatheter control. The system worked without any problems, and did not interfere with any procedures. In experimental coil embolization, delivery wire control using the foot switches as well as microcatheter manipulation helped to achieve successful insertion of coils. This system could offer the possibility of developing safer and more efficient coil embolization. Although we aim at total mechanization and automation of procedures in the future, microcatheter manipulation and synchronized delivery wire control are still indispensable using this system. PMID:23693038
Lance, Blake W.; Smith, Barton L.
2016-06-23
Transient convection has been investigated experimentally for the purpose of providing Computational Fluid Dynamics (CFD) validation benchmark data. A specialized facility for validation benchmark experiments called the Rotatable Buoyancy Tunnel was used to acquire thermal and velocity measurements of flow over a smooth, vertical heated plate. The initial condition was forced convection downward with subsequent transition to mixed convection, ending with natural convection upward after a flow reversal. Data acquisition through the transient was repeated for ensemble-averaged results. With simple flow geometry, validation data were acquired at the benchmark level. All boundary conditions (BCs) were measured and their uncertainties quantified.more » Temperature profiles on all four walls and the inlet were measured, as well as as-built test section geometry. Inlet velocity profiles and turbulence levels were quantified using Particle Image Velocimetry. System Response Quantities (SRQs) were measured for comparison with CFD outputs and include velocity profiles, wall heat flux, and wall shear stress. Extra effort was invested in documenting and preserving the validation data. Details about the experimental facility, instrumentation, experimental procedure, materials, BCs, and SRQs are made available through this paper. As a result, the latter two are available for download and the other details are included in this work.« less
Hydro-dynamic damping theory in flowing water
NASA Astrophysics Data System (ADS)
Monette, C.; Nennemann, B.; Seeley, C.; Coutu, A.; Marmont, H.
2014-03-01
Fluid-structure interaction (FSI) has a major impact on the dynamic response of the structural components of hydroelectric turbines. On mid-head to high-head Francis runners, the rotor-stator interaction (RSI) phenomenon always has to be considered carefully during the design phase to avoid operational issues later on. The RSI dynamic response amplitudes are driven by three main factors: (1) pressure forcing amplitudes, (2) excitation frequencies in relation to natural frequencies and (3) damping. The prediction of the two first factors has been largely documented in the literature. However, the prediction of fluid damping has received less attention in spite of being critical when the runner is close to resonance. Experimental damping measurements in flowing water on hydrofoils were presented previously. Those results showed that the hydro-dynamic damping increased linearly with the flow. This paper presents development and validation of a mathematical model, based on momentum exchange, to predict damping due to fluid structure interaction in flowing water. The model is implemented as an analytical procedure for simple structures, such as cantilever beams, but is also implemented in more general ways using three different approaches for more complex structures such as runner blades: a finite element procedure, a CFD modal work based approach and a CFD 1DOF approach. The mathematical model and all three implementation approaches are shown to agree well with experimental results.
Banitaba, Sayed Hossein; Safari, Javad; Khalili, Shiva Dehghan
2013-01-01
A green and simple approach to assembling of 2-amino-4,8-dihydropyrano[3,2-b]pyran-3-carbonitrile scaffolds via three-component reaction of kojic acid, malononitrile, and aromatic aldehydes in aqueous media under ultrasound irradiation is described. The combinatorial synthesis was achieved for this methodology with applying ultrasound irradiation while making use of water as green solvent. In comparison to conventional methods, experimental simplicity, good functional group tolerance, excellent yields, short routine, and selectivity without the need for a transition metal or base catalyst are prominent features of this green procedure. Copyright © 2012 Elsevier B.V. All rights reserved.
Bandgap engineering of InGaAsP/InP laser structure by photo-absorption-induced point defects
NASA Astrophysics Data System (ADS)
Kaleem, Mohammad; Nazir, Sajid; Saqib, Nazar Abbas
2016-03-01
Integration of photonic components on the same photonic wafer permits future optical communication systems to be dense and advanced performance. This enables very fast information handling between photonic active components interconnected through passive optical low loss channels. We demonstrate the UV-Laser based Quantum Well Intermixing (QWI) procedure to engineer the band-gap of compressively strained InGaAsP/InP Quantum Well (QW) laser material. We achieved around 135nm of blue-shift by simply applying excimer laser (λ= 248nm). The under observation laser processed material also exhibits higher photoluminescence (PL) intensity. Encouraging experimental results indicate that this simple technique has the potential to produce photonic integrated devices and circuits.
Size and habit evolution of PETN crystals - a lattice Monte Carlo study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zepeda-Ruiz, L A; Maiti, A; Gee, R
2006-02-28
Starting from an accurate inter-atomic potential we develop a simple scheme of generating an ''on-lattice'' molecular potential of short range, which is then incorporated into a lattice Monte Carlo code for simulating size and shape evolution of nanocrystallites. As a specific example, we test such a procedure on the morphological evolution of a molecular crystal of interest to us, e.g., Pentaerythritol Tetranitrate, or PETN, and obtain realistic facetted structures in excellent agreement with experimental morphologies. We investigate several interesting effects including, the evolution of the initial shape of a ''seed'' to an equilibrium configuration, and the variation of growth morphologymore » as a function of the rate of particle addition relative to diffusion.« less
High-precision control of LSRM based X-Y table for industrial applications.
Pan, J F; Cheung, Norbert C; Zou, Yu
2013-01-01
The design of an X-Y table applying direct-drive linear switched reluctance motor (LSRM) principle is proposed in this paper. The proposed X-Y table has the characteristics of low cost, simple and stable mechanical structure. After the design procedure is introduced, an adaptive position control method based on online parameter identification and pole-placement regulation scheme is developed for the X-Y table. Experimental results prove the feasibility and its priority over a traditional PID controller with better dynamic response, static performance and robustness to disturbances. It is expected that the novel two-dimensional direct-drive system find its applications in high-precision manufacture area. Copyright © 2012 ISA. Published by Elsevier Ltd. All rights reserved.
A quantitative witness for Greenberger-Horne-Zeilinger entanglement.
Eltschka, Christopher; Siewert, Jens
2012-01-01
Along with the vast progress in experimental quantum technologies there is an increasing demand for the quantification of entanglement between three or more quantum systems. Theory still does not provide adequate tools for this purpose. The objective is, besides the quest for exact results, to develop operational methods that allow for efficient entanglement quantification. Here we put forward an analytical approach that serves both these goals. We provide a simple procedure to quantify Greenberger-Horne-Zeilinger-type multipartite entanglement in arbitrary three-qubit states. For two qubits this method is equivalent to Wootters' seminal result for the concurrence. It establishes a close link between entanglement quantification and entanglement detection by witnesses, and can be generalised both to higher dimensions and to more than three parties.
Bağda, Esra; Altundağ, Huseyin; Tüzen, Mustafa; Soylak, Mustafa
2017-08-01
In the present study, a simple, mono step deep eutectic solvent (DES) extraction was developed for selective extraction of copper from sediment samples. The optimization of all experimental parameters, e.g. DES type, sample/DES ratio, contact time and temperature were performed with using BCR-280 R (lake sediment certified reference material). The limit of detection (LOD) and the limit of quantification (LOQ) were found as 1.2 and 3.97 µg L -1 , respectively. The RSD of the procedure was 7.5%. The proposed extraction method was applied to river and lake sediments sampled from Serpincik, Çeltek, Kızılırmak (Fadl and Tecer region of the river), Sivas-Turkey.
NASA Astrophysics Data System (ADS)
Salatino, P.; Solimene, R.; Chirone, R.
The de-NOx potential of coal and of dried and pelletized sewage sludge, a waste-derived fuel candidate for cofiring with coal, is assessed. The experimental procedure is based on operation of a bench scale fluidized bed reactor where NO-doped nitrogen is contacted with batches of the fuel. A second type of experiment has been purposely designed to assess the loss of reactivity of chars toward gasification by NOx as char is heat-treated for pre-set times at temperatures typical of fluidized bed combustion. A simple phenomenological model is developed to shed light on the basic features of the interaction between heterogeneous char-NOx reaction and thermal annealing of the char.
Versatile module for experiments with focussing neutron guides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, T.; Pfleiderer, C.; Böni, P.
2014-09-22
We report the development of a versatile module that permits fast and reliable use of focussing neutron guides under varying scattering angles. A simple procedure for setting up the module and neutron guides is illustrated by typical intensity patterns to highlight operational aspects as well as typical parasitic artefacts. Combining a high-precision alignment table with separate housings for the neutron guides on kinematic mounts, the change-over between neutron guides with different focussing characteristics requires no readjustments of the experimental setup. Exploiting substantial gain factors, we demonstrate the performance of this versatile neutron scattering module in a study of the effectsmore » of uniaxial stress on the domain populations in the transverse spin density wave phase of single crystal Cr.« less
Design and analysis of unequal split Bagley power dividers
NASA Astrophysics Data System (ADS)
Abu-Alnadi, Omar; Dib, Nihad; Al-Shamaileh, Khair; Sheta, Abdelfattah
2015-03-01
In this article, we propose a general design procedure to develop unequal split Bagley power dividers (BPDs). Based on the mathematical approach carried out in the insight of simple circuit and transmission line theories, exact design equations for 3-way and 5-way BPDs are derived. Utilising the developed equations leads to power dividers with the ability of offering different output power ratios through a suitable choice of the characteristic impedances of the interconnecting transmission lines. For verification purposes, a 1:2:1 3-way, 1:2:1:2:1 5-way and 1:3:1:3:1 5-way BPDs are designed and fabricated. The experimental and full-wave simulation results prove the validity of the designed unequal split BPDs.
Concentrator optical characterization using computer mathematical modelling and point source testing
NASA Technical Reports Server (NTRS)
Dennison, E. W.; John, S. L.; Trentelman, G. F.
1984-01-01
The optical characteristics of a paraboloidal solar concentrator are analyzed using the intercept factor curve (a format for image data) to describe the results of a mathematical model and to represent reduced data from experimental testing. This procedure makes it possible not only to test an assembled concentrator, but also to evaluate single optical panels or to conduct non-solar tests of an assembled concentrator. The use of three-dimensional ray tracing computer programs to calculate the mathematical model is described. These ray tracing programs can include any type of optical configuration from simple paraboloids to array of spherical facets and can be adapted to microcomputers or larger computers, which can graphically display real-time comparison of calculated and measured data.
NASA Astrophysics Data System (ADS)
Douglas-Gallardo, Oscar A.; Burgos-Paci, Maxi A.; Mendoza-Cruz, Rubén; Putnam, Karl G.; Josefina Arellano-Jiménez, M.; José-Yacamán, Miguel; Mariscal, Marcelo M.; Macagno, Vicente A.; Sánchez, Cristián G.; Pérez, Manuel A.
2018-03-01
A novel strategy to synthesize photoluminescent silicon nanocrystals (SiNCs) from a reaction between tetraethylorthosilicate (TEOS) and trimethyl-hexadecyl-ammonium borohydride (CTABH4) in organic solvent is presented. The formation reaction occurs spontaneously at room temperature in homogeneous phase. The produced silicon nanocrystals are characterized by using their photoluminescent properties and via HRTEM. In addition, theoretical calculations of the optical absorption spectrum of silicon quantum dots in vacuum with different sizes and surface moieties were performed in order to compare with the experimental findings. The new chemical reaction is simple and can be implemented to produce silicon nanocrystal with regular laboratory materials by performing easy and safe procedures. [Figure not available: see fulltext.
Day, Charles A.; Kraft, Lewis J.; Kang, Minchul; Kenworthy, Anne K.
2012-01-01
Fluorescence recovery after photobleaching (FRAP) is a powerful, versatile and widely accessible tool to monitor molecular dynamics in living cells that can be performed using modern confocal microscopes. Although the basic principles of FRAP are simple, quantitative FRAP analysis requires careful experimental design, data collection and analysis. In this review we discuss the theoretical basis for confocal FRAP, followed by step-by-step protocols for FRAP data acquisition using a laser scanning confocal microscope for (1) measuring the diffusion of a membrane protein, (2) measuring the diffusion of a soluble protein, and (3) analysis of intracellular trafficking. Finally, data analysis procedures are discussed and an equation for determining the diffusion coefficient of a molecular species undergoing pure diffusion is presented. PMID:23042527
NASA Astrophysics Data System (ADS)
Santos, Marlus Alves Dos; Teixeira, Francesco Brugnera; Moreira, Heline Hellen Teixeira; Rodrigues, Adele Aud; Machado, Fabrício Castro; Clemente, Tatiana Mordente; Brigido, Paula Cristina; Silva, Rebecca Tavares E.; Purcino, Cecílio; Gomes, Rafael Gonçalves Barbosa; Bahia, Diana; Mortara, Renato Arruda; Munte, Claudia Elisabeth; Horjales, Eduardo; da Silva, Claudio Vieira
2014-03-01
Structural studies of proteins normally require large quantities of pure material that can only be obtained through heterologous expression systems and recombinant technique. In these procedures, large amounts of expressed protein are often found in the insoluble fraction, making protein purification from the soluble fraction inefficient, laborious, and costly. Usually, protein refolding is avoided due to a lack of experimental assays that can validate correct folding and that can compare the conformational population to that of the soluble fraction. Herein, we propose a validation method using simple and rapid 1D 1H nuclear magnetic resonance (NMR) spectra that can efficiently compare protein samples, including individual information of the environment of each proton in the structure.
A quantitative witness for Greenberger-Horne-Zeilinger entanglement
Eltschka, Christopher; Siewert, Jens
2012-01-01
Along with the vast progress in experimental quantum technologies there is an increasing demand for the quantification of entanglement between three or more quantum systems. Theory still does not provide adequate tools for this purpose. The objective is, besides the quest for exact results, to develop operational methods that allow for efficient entanglement quantification. Here we put forward an analytical approach that serves both these goals. We provide a simple procedure to quantify Greenberger-Horne-Zeilinger–type multipartite entanglement in arbitrary three-qubit states. For two qubits this method is equivalent to Wootters' seminal result for the concurrence. It establishes a close link between entanglement quantification and entanglement detection by witnesses, and can be generalised both to higher dimensions and to more than three parties. PMID:23267431
NASA Astrophysics Data System (ADS)
Azizkhani, Vahid; Montazeri, Faezeh; Molashahi, Ebrahim; Ramazani, Ali
2017-07-01
Magnetic nanoparticles of copper ferrite (CuFe2O4 MNPs) have been simply prepared and applied as an efficient recyclable and reusable catalyst for the green synthesis of 2,4,6,8,10,12-hexabenzyl-2,4,6,8,10,12-hexaazatetracyclo[5.5.0.05,9.03,11]dodecane (HBIW). The structure of the synthesized pure HBIW (recrystallization from ethanol) was confirmed by using various spectral techniques like infrared (IR), 1H-NMR, 13C-NMR and some of its physical properties. The prepared catalyst was characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier transform infrared (FTIR). In addition, CuFe2O4 MNPs could be reused up to seven runs without any significant loss of activity. Finally, the remarkable advantages of this method are the simple experimental procedure, shorter reaction times, simple workup, and green aspects by avoiding toxic catalysts and high yield of product.
One-step preparation of antimicrobial silver nanoparticles in polymer matrix
NASA Astrophysics Data System (ADS)
Lyutakov, O.; Kalachyova, Y.; Solovyev, A.; Vytykacova, S.; Svanda, J.; Siegel, J.; Ulbrich, P.; Svorcik, V.
2015-03-01
Simple one-step procedure for in situ preparation of silver nanoparticles (AgNPs) in the polymer thin films is described. Nanoparticles (NPs) were prepared by reaction of N-methyl pyrrolidone with silver salt in semi-dry polymer film and characterized by transmission electron microscopy, XPS, and UV-Vis spectroscopy techniques. Direct synthesis of NPs in polymer has several advantages; even though it avoids time-consuming NPs mixing with polymer matrix, uniform silver distribution in polymethylmethacrylate (PMMA) films is achieved without necessity of additional stabilization. The influence of the silver concentration, reaction temperature and time on reaction conversion rate, and the size and size-distribution of the AgNPs was investigated. Polymer films doped with AgNPs were tested for their antibacterial activity on Gram-negative bacteria. Antimicrobial properties of AgNPs/PMMA films were found to be depended on NPs concentration, their size and distribution. Proposed one-step synthesis of functional polymer containing AgNPs is environmentally friendly, experimentally simple and extremely quick. It opens up new possibilities in development of antimicrobial coatings with medical and sanitation applications.
NASA Astrophysics Data System (ADS)
Kim, Yong-Hyun; Kim, Ki-Hyun
2015-07-01
The analysis of polycyclic aromatic hydrocarbons (PAH) in ambient air requires the tedious experimental steps of both sampling and pretreatment (e.g., extraction or clean-up). To replace pre-existing conventional methods, a simple, rapid, and novel technique was developed to measure gas-particle fractionation of PAH in ambient air based on ‘sorbent tube-thermal desorption-gas chromatograph-mass spectrometer (ST-TD-GC-MS)’. The separate collection and analysis of ambient PAHs were achieved independently by two serially connected STs. The basic quality assurance confirmed good linearity, precision, and high sensitivity to eliminate the need for complicated pretreatment procedures with the detection limit (16 PAHs: 13.1 ± 7.04 pg). The analysis of real ambient PAH samples showed a clear fractionation between gas (two-three ringed PAHs) and particulate phases (five-six ringed PAHs). In contrast, for intermediate (four ringed) PAHs (fluoranthene, pyrene, benz[a]anthracene, and chrysene), a highly systematic/gradual fractionation was established. It thus suggests a promising role of ST-TD-GC-MS as measurement system in acquiring a reliable database of airborne PAH.
Giovannini, Giannina; Sbarciog, Mihaela; Steyer, Jean-Philippe; Chamy, Rolando; Vande Wouwer, Alain
2018-05-01
Hydrogen has been found to be an important intermediate during anaerobic digestion (AD) and a key variable for process monitoring as it gives valuable information about the stability of the reactor. However, simple dynamic models describing the evolution of hydrogen are not commonplace. In this work, such a dynamic model is derived using a systematic data driven-approach, which consists of a principal component analysis to deduce the dimension of the minimal reaction subspace explaining the data, followed by an identification of the kinetic parameters in the least-squares sense. The procedure requires the availability of informative data sets. When the available data does not fulfill this condition, the model can still be built from simulated data, obtained using a detailed model such as ADM1. This dynamic model could be exploited in monitoring and control applications after a re-identification of the parameters using actual process data. As an example, the model is used in the framework of a control strategy, and is also fitted to experimental data from raw industrial wine processing wastewater. Copyright © 2018 Elsevier Ltd. All rights reserved.
Powell, Jane; Letson, Susan; Davidoff, Jules; Valentine, Tim; Greenwood, Richard
2008-04-01
Twenty patients with impairments of face recognition, in the context of a broader pattern of cognitive deficits, were administered three new training procedures derived from contemporary theories of face processing to enhance their learning of new faces: semantic association (being given additional verbal information about the to-be-learned faces); caricaturing (presentation of caricatured versions of the faces during training and veridical versions at recognition testing); and part recognition (focusing patients on distinctive features during the training phase). Using a within-subjects design, each training procedure was applied to a different set of 10 previously unfamiliar faces and entailed six presentations of each face. In a "simple exposure" control procedure (SE), participants were given six presentations of another set of faces using the same basic protocol but with no further elaboration. Order of the four procedures was counterbalanced, and each condition was administered on a different day. A control group of 12 patients with similar levels of face recognition impairment were trained on all four sets of faces under SE conditions. Compared to the SE condition, all three training procedures resulted in more accurate discrimination between the 10 studied faces and 10 distractor faces in a post-training recognition test. This did not reflect any intrinsic lesser memorability of the faces used in the SE condition, as evidenced by the comparable performance across face sets by the control group. At the group level, the three experimental procedures were of similar efficacy, and associated cognitive deficits did not predict which technique would be most beneficial to individual patients; however, there was limited power to detect such associations. Interestingly, a pure prosopagnosic patient who was tested separately showed benefit only from the part recognition technique. Possible mechanisms for the observed effects, and implications for rehabilitation, are discussed.
Leili, Mostafa; Pirmoghani, Amin; Samadi, Mohammad Taghi; Shokoohi, Reza; Roshanaei, Ghodratollah; Poormohammadi, Ali
2016-11-01
The objective of this study was to determine the residual concentrations of ethion and imidacloprid in cucumbers grown in greenhouse. The effect of some simple processing procedures on both ethion and imidacloprid residues were also studied. Ten active greenhouses that produce cucumber were randomly selected. Ethion and imidacloprid as the most widely used pesticides were measured in cucumber samples of studied greenhouses. Moreover, the effect of storing, washing, and peeling as simple processing procedures on both ethion and imidacloprid residues were investigated. One hour after pesticide application; the maximum residue levels (MRLs) of ethion and imidacloprid were higher than that of Codex standard level. One day after pesticide application, the levels of pesticides were decreased about 35 and 31% for ethion and imidacloprid, respectively, which still were higher than the MRL. Washing procedure led to about 51 and 42.5% loss in ethion and imidacloprid residues, respectively. Peeling procedure also led to highest loss of 93.4 and 63.7% in ethion and imidacloprid residues, respectively. The recovery for both target analytes was in the range between 88 and 102%. The residue values in collected samples one hour after pesticides application were higher than standard value. The storing, washing, and peeling procedures lead to the decrease of pesticide residues in greenhouse cucumbers. Among them, the peeling procedure has the greatest impact on residual reduction. Therefore, these procedures can be used as simple and effective processing techniques for reducing and removing pesticides from greenhouse products before their consumption.
Parameter estimation for lithium ion batteries
NASA Astrophysics Data System (ADS)
Santhanagopalan, Shriram
With an increase in the demand for lithium based batteries at the rate of about 7% per year, the amount of effort put into improving the performance of these batteries from both experimental and theoretical perspectives is increasing. There exist a number of mathematical models ranging from simple empirical models to complicated physics-based models to describe the processes leading to failure of these cells. The literature is also rife with experimental studies that characterize the various properties of the system in an attempt to improve the performance of lithium ion cells. However, very little has been done to quantify the experimental observations and relate these results to the existing mathematical models. In fact, the best of the physics based models in the literature show as much as 20% discrepancy when compared to experimental data. The reasons for such a big difference include, but are not limited to, numerical complexities involved in extracting parameters from experimental data and inconsistencies in interpreting directly measured values for the parameters. In this work, an attempt has been made to implement simplified models to extract parameter values that accurately characterize the performance of lithium ion cells. The validity of these models under a variety of experimental conditions is verified using a model discrimination procedure. Transport and kinetic properties are estimated using a non-linear estimation procedure. The initial state of charge inside each electrode is also maintained as an unknown parameter, since this value plays a significant role in accurately matching experimental charge/discharge curves with model predictions and is not readily known from experimental data. The second part of the dissertation focuses on parameters that change rapidly with time. For example, in the case of lithium ion batteries used in Hybrid Electric Vehicle (HEV) applications, the prediction of the State of Charge (SOC) of the cell under a variety of road conditions is important. An algorithm to predict the SOC in time intervals as small as 5 ms is of critical demand. In such cases, the conventional non-linear estimation procedure is not time-effective. There exist methodologies in the literature, such as those based on fuzzy logic; however, these techniques require a lot of computational storage space. Consequently, it is not possible to implement such techniques on a micro-chip for integration as a part of a real-time device. The Extended Kalman Filter (EKF) based approach presented in this work is a first step towards developing an efficient method to predict online, the State of Charge of a lithium ion cell based on an electrochemical model. The final part of the dissertation focuses on incorporating uncertainty in parameter values into electrochemical models using the polynomial chaos theory (PCT).
Olmos, José Manuel; Laborda, Eduardo; Ortuño, Joaquín Ángel; Molina, Ángela
2017-03-01
The quantitative characterization of inclusion complexes formed in aqueous phase between organic ions and hydrophilic hosts by ion-transfer voltammetry with solvent polymeric membrane ion sensors is studied, both in a theoretical and experimental way. Simple analytical solutions are presented for the determination of the binding constant of the complex from the variation with the host concentration of the electrochemical signal. These solutions are valid for any voltammetric technique and for solvent polymeric membrane ion sensors comprising one polarisable interface (1PI) and also, for the first time, two polarisable interfaces (2PIs). Suitable experimental conditions and data analysis procedures are discussed and applied to the study of the interactions of a common ionic liquid cation (1-octyl-3-metyl-imidazolium) and an ionisable drug (clomipramine) with two hydrophilic cyclodextrins: α-cyclodextrin and 2-hydroxypropyl-β-cyclodextrin. The experimental study is performed via square wave voltammetry with 2PIs and 1PI solvent polymeric membranes and in both cases the electrochemical experiments enable the detection of inclusion complexes and the determination of the corresponding binding constant. Copyright © 2016 Elsevier B.V. All rights reserved.
Full-degrees-of-freedom frequency based substructuring
NASA Astrophysics Data System (ADS)
Drozg, Armin; Čepon, Gregor; Boltežar, Miha
2018-01-01
Dividing the whole system into multiple subsystems and a separate dynamic analysis is common practice in the field of structural dynamics. The substructuring process improves the computational efficiency and enables an effective realization of the local optimization, modal updating and sensitivity analyses. This paper focuses on frequency-based substructuring methods using experimentally obtained data. An efficient substructuring process has already been demonstrated using numerically obtained frequency-response functions (FRFs). However, the experimental process suffers from several difficulties, among which, many of them are related to the rotational degrees of freedom. Thus, several attempts have been made to measure, expand or combine numerical correction methods in order to obtain a complete response model. The proposed methods have numerous limitations and are not yet generally applicable. Therefore, in this paper an alternative approach based on experimentally obtained data only, is proposed. The force-excited part of the FRF matrix is measured with piezoelectric translational and rotational direct accelerometers. The incomplete moment-excited part of the FRF matrix is expanded, based on the modal model. The proposed procedure is integrated in a Lagrange Multiplier Frequency Based Substructuring method and demonstrated on a simple beam structure, where the connection coordinates are mainly associated with the rotational degrees of freedom.
NASA Astrophysics Data System (ADS)
Gomez, Jamie; Nelson, Ruben; Kalu, Egwu E.; Weatherspoon, Mark H.; Zheng, Jim P.
2011-05-01
Equivalent circuit model (EMC) of a high-power Li-ion battery that accounts for both temperature and state of charge (SOC) effects known to influence battery performance is presented. Electrochemical impedance measurements of a commercial high power Li-ion battery obtained in the temperature range 20 to 50 °C at various SOC values was used to develop a simple EMC which was used in combination with a non-linear least squares fitting procedure that used thirteen parameters for the analysis of the Li-ion cell. The experimental results show that the solution and charge transfer resistances decreased with increase in cell operating temperature and decreasing SOC. On the other hand, the Warburg admittance increased with increasing temperature and decreasing SOC. The developed model correlations that are capable of being used in process control algorithms are presented for the observed impedance behavior with respect to temperature and SOC effects. The predicted model parameters for the impedance elements Rs, Rct and Y013 show low variance of 5% when compared to the experimental data and therefore indicates a good statistical agreement of correlation model to the actual experimental values.
Laser Speckle Photography: Some Simple Experiments for the Undergraduate Laboratory.
ERIC Educational Resources Information Center
Bates, B.; And Others
1986-01-01
Describes simple speckle photography experiments which are easy to set up and require only low cost standard laboratory equipment. Included are procedures for taking single, double, and multiple exposures. (JN)
Rendering the "Not-So-Simple" Pendulum Experimentally Accessible.
ERIC Educational Resources Information Center
Jackson, David P.
1996-01-01
Presents three methods for obtaining experimental data related to acceleration of a simple pendulum. Two of the methods involve angular position measurements and the subsequent calculation of the acceleration while the third method involves a direct measurement of the acceleration. Compares these results with theoretical calculations and…
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
Operator Priming and Generalization of Practice in Adults' Simple Arithmetic
ERIC Educational Resources Information Center
Chen, Yalin; Campbell, Jamie I. D.
2016-01-01
There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication,…
Foglia, Giovanni; Mistrangelo, Emanuela; Lijoi, Davide; Alessandri, Franco; Ragni, Nicola
2007-07-01
To analyse prospectively the effectiveness of a new simple, minimally invasive, and cost-effective technique for the treatment of female urinary stress incontinence: the transfascial vaginal tape (TFT). In a prospective study, we enrolled 45 women undergoing TFT with or without hysterectomy and/or another pelvic reconstructive procedure between 1st December 2003 and 31st December. TFT consists of a tension-free urethrosuspension using a sling located at the mid-urethral level and placed laterally in the endopelvic fascia previously perforated. Follow-up evaluations were established at 3 and 6 months and at 1 year after the operation. During each follow-up, women underwent cough stress test and they answered to the "Incontinence quality of life questionnaire" (I-QOL), to the Patient Global Impression of Severity (PGI-S) and of Improvement (PGI-I) questions. Thirty-nine patients (88.9%) had a follow-up examination 1 year after surgery. Of these, 30 (76.9%) were defined cured, 6 (15.4%) improved and 3 (7.7%) failed. TFT procedure can be considered a simple, safe and cost-effective procedure for the treatment of stress urinary incontinence and can be an alternative to tension-free vaginal tape or transobturator route for sub-urethral tape procedures.
A Robust Adaptive Autonomous Approach to Optimal Experimental Design
NASA Astrophysics Data System (ADS)
Gu, Hairong
Experimentation is the fundamental tool of scientific inquiries to understand the laws governing the nature and human behaviors. Many complex real-world experimental scenarios, particularly in quest of prediction accuracy, often encounter difficulties to conduct experiments using an existing experimental procedure for the following two reasons. First, the existing experimental procedures require a parametric model to serve as the proxy of the latent data structure or data-generating mechanism at the beginning of an experiment. However, for those experimental scenarios of concern, a sound model is often unavailable before an experiment. Second, those experimental scenarios usually contain a large number of design variables, which potentially leads to a lengthy and costly data collection cycle. Incompetently, the existing experimental procedures are unable to optimize large-scale experiments so as to minimize the experimental length and cost. Facing the two challenges in those experimental scenarios, the aim of the present study is to develop a new experimental procedure that allows an experiment to be conducted without the assumption of a parametric model while still achieving satisfactory prediction, and performs optimization of experimental designs to improve the efficiency of an experiment. The new experimental procedure developed in the present study is named robust adaptive autonomous system (RAAS). RAAS is a procedure for sequential experiments composed of multiple experimental trials, which performs function estimation, variable selection, reverse prediction and design optimization on each trial. Directly addressing the challenges in those experimental scenarios of concern, function estimation and variable selection are performed by data-driven modeling methods to generate a predictive model from data collected during the course of an experiment, thus exempting the requirement of a parametric model at the beginning of an experiment; design optimization is performed to select experimental designs on the fly of an experiment based on their usefulness so that fewest designs are needed to reach useful inferential conclusions. Technically, function estimation is realized by Bayesian P-splines, variable selection is realized by Bayesian spike-and-slab prior, reverse prediction is realized by grid-search and design optimization is realized by the concepts of active learning. The present study demonstrated that RAAS achieves statistical robustness by making accurate predictions without the assumption of a parametric model serving as the proxy of latent data structure while the existing procedures can draw poor statistical inferences if a misspecified model is assumed; RAAS also achieves inferential efficiency by taking fewer designs to acquire useful statistical inferences than non-optimal procedures. Thus, RAAS is expected to be a principled solution to real-world experimental scenarios pursuing robust prediction and efficient experimentation.
14 CFR 21.275 - Experimental certificates.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Experimental certificates. 21.275 Section... CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Delegation Option Authorization Procedures § 21.275 Experimental certificates. (a) The manufacturer shall, before issuing an experimental certificate, obtain from the...
14 CFR 21.275 - Experimental certificates.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Experimental certificates. 21.275 Section... CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Delegation Option Authorization Procedures § 21.275 Experimental certificates. (a) The manufacturer shall, before issuing an experimental certificate, obtain from the...
MOtoNMS: A MATLAB toolbox to process motion data for neuromusculoskeletal modeling and simulation.
Mantoan, Alice; Pizzolato, Claudio; Sartori, Massimo; Sawacha, Zimi; Cobelli, Claudio; Reggiani, Monica
2015-01-01
Neuromusculoskeletal modeling and simulation enable investigation of the neuromusculoskeletal system and its role in human movement dynamics. These methods are progressively introduced into daily clinical practice. However, a major factor limiting this translation is the lack of robust tools for the pre-processing of experimental movement data for their use in neuromusculoskeletal modeling software. This paper presents MOtoNMS (matlab MOtion data elaboration TOolbox for NeuroMusculoSkeletal applications), a toolbox freely available to the community, that aims to fill this lack. MOtoNMS processes experimental data from different motion analysis devices and generates input data for neuromusculoskeletal modeling and simulation software, such as OpenSim and CEINMS (Calibrated EMG-Informed NMS Modelling Toolbox). MOtoNMS implements commonly required processing steps and its generic architecture simplifies the integration of new user-defined processing components. MOtoNMS allows users to setup their laboratory configurations and processing procedures through user-friendly graphical interfaces, without requiring advanced computer skills. Finally, configuration choices can be stored enabling the full reproduction of the processing steps. MOtoNMS is released under GNU General Public License and it is available at the SimTK website and from the GitHub repository. Motion data collected at four institutions demonstrate that, despite differences in laboratory instrumentation and procedures, MOtoNMS succeeds in processing data and producing consistent inputs for OpenSim and CEINMS. MOtoNMS fills the gap between motion analysis and neuromusculoskeletal modeling and simulation. Its support to several devices, a complete implementation of the pre-processing procedures, its simple extensibility, the available user interfaces, and its free availability can boost the translation of neuromusculoskeletal methods in daily and clinical practice.
NASA Astrophysics Data System (ADS)
Garcia-Molina, Rafael; del Mazo, Alejandro; Velasco, Santiago
2018-01-01
We present a simple and cheap experimental setup that clearly shows how the colors of the white light spectrum after passing a prism do not recombine when emerging from an identical second prism, as it is still found in many references.
ERIC Educational Resources Information Center
Garcia-Molina, Rafael; del Mazo, Alejandro; Velasco, Santiago
2018-01-01
We present a simple and cheap experimental setup that clearly shows how the colors of the white light spectrum after passing a prism do not recombine when emerging from an identical second prism, as it is still found in many references.
A Simple Experiment Demonstrating the Allosteric Regulation of Yeast Pyruvate Kinase.
ERIC Educational Resources Information Center
Taber, Richard L.; Campbell, Angela; Spencer, Scott
1998-01-01
Explains the procedures used to determine the regulatory properties of yeast pyruvate kinase. Involves a partial purification using PEG precipitation that can be done in one laboratory period with simple equipment. (DDR)
Additivity of nonlinear biomass equations
Bernard R. Parresol
2001-01-01
Two procedures that guarantee the property of additivity among the components of tree biomass and total tree biomass utilizing nonlinear functions are developed. Procedure 1 is a simple combination approach, and procedure 2 is based on nonlinear joint-generalized regression (nonlinear seemingly unrelated regressions) with parameter restrictions. Statistical theory is...
Using Mouse Mammary Tumor Cells to Teach Core Biology Concepts: A Simple Lab Module.
McIlrath, Victoria; Trye, Alice; Aguanno, Ann
2015-06-18
Undergraduate biology students are required to learn, understand and apply a variety of cellular and molecular biology concepts and techniques in preparation for biomedical, graduate and professional programs or careers in science. To address this, a simple laboratory module was devised to teach the concepts of cell division, cellular communication and cancer through the application of animal cell culture techniques. Here the mouse mammary tumor (MMT) cell line is used to model for breast cancer. Students learn to grow and characterize these animal cells in culture and test the effects of traditional and non-traditional chemotherapy agents on cell proliferation. Specifically, students determine the optimal cell concentration for plating and growing cells, learn how to prepare and dilute drug solutions, identify the best dosage and treatment time course of the antiproliferative agents, and ascertain the rate of cell death in response to various treatments. The module employs both a standard cell counting technique using a hemocytometer and a novel cell counting method using microscopy software. The experimental procedure lends to open-ended inquiry as students can modify critical steps of the protocol, including testing homeopathic agents and over-the-counter drugs. In short, this lab module requires students to use the scientific process to apply their knowledge of the cell cycle, cellular signaling pathways, cancer and modes of treatment, all while developing an array of laboratory skills including cell culture and analysis of experimental data not routinely taught in the undergraduate classroom.
Chen, Shaoxia; McMullan, Greg; Faruqi, Abdul R; Murshudov, Garib N; Short, Judith M; Scheres, Sjors H W; Henderson, Richard
2013-12-01
Three-dimensional (3D) structure determination by single particle electron cryomicroscopy (cryoEM) involves the calculation of an initial 3D model, followed by extensive iterative improvement of the orientation determination of the individual particle images and the resulting 3D map. Because there is much more noise than signal at high resolution in the images, this creates the possibility of noise reinforcement in the 3D map, which can give a false impression of the resolution attained. The balance between signal and noise in the final map at its limiting resolution depends on the image processing procedure and is not easily predicted. There is a growing awareness in the cryoEM community of how to avoid such over-fitting and over-estimation of resolution. Equally, there has been a reluctance to use the two principal methods of avoidance because they give lower resolution estimates, which some people believe are too pessimistic. Here we describe a simple test that is compatible with any image processing protocol. The test allows measurement of the amount of signal and the amount of noise from overfitting that is present in the final 3D map. We have applied the method to two different sets of cryoEM images of the enzyme beta-galactosidase using several image processing packages. Our procedure involves substituting the Fourier components of the initial particle image stack beyond a chosen resolution by either the Fourier components from an adjacent area of background, or by simple randomisation of the phases of the particle structure factors. This substituted noise thus has the same spectral power distribution as the original data. Comparison of the Fourier Shell Correlation (FSC) plots from the 3D map obtained using the experimental data with that from the same data with high-resolution noise (HR-noise) substituted allows an unambiguous measurement of the amount of overfitting and an accompanying resolution assessment. A simple formula can be used to calculate an unbiased FSC from the two curves, even when a substantial amount of overfitting is present. The approach is software independent. The user is therefore completely free to use any established method or novel combination of methods, provided the HR-noise test is carried out in parallel. Applying this procedure to cryoEM images of beta-galactosidase shows how overfitting varies greatly depending on the procedure, but in the best case shows no overfitting and a resolution of ~6 Å. (382 words). © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.
Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti
2014-02-01
Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.
Sunil, Kanoujia; Gupta, Archika; Chaubey, Digamber; Pandey, Anand; Kureel, Shiv Narain; Verma, Ajay Kumar
2018-01-01
To report the clinical application of the new surgical technique of antireflux procedure without creating submucosal tunnel for surgical correction of vesicoureteric reflux during bladder closure in exstrophy. Based on the report of published experimental technique, the procedure was clinically executed in seven patients of classic exstrophy bladder with small bladder plate with polyps, where the creation of submucosal tunnel was not possible, in last 18 months. Ureters were mobilized. A rectangular patch of bladder mucosa at trigone was removed exposing the detrusor. Mobilized urteres were advanced, crossed and anchored to exposed detrusor parallel to each other. Reconstruction included bladder and epispadias repair with abdominal wall closure. The outcome was measured with the assessment of complications, abolition of reflux on cystogram and upper tract status. At 3-month follow-up cystogram, reflux was absent in all. Follow-up ultrasound revealed mild dilatation of pelvis and ureter in one. The technique of extra-mucosal ureteric reimplantation without the creation of submucosal tunnel is simple to execute without risk and complications and effectively provides an antireflux mechanism for the preservation of upper tract in bladder exstrophy. With the use of this technique, reflux can be prevented since the very beginning of exstrophy reconstruction.
Development of the Quality Assurance/Quality Control Procedures for a Neutron Interrogation System
NASA Astrophysics Data System (ADS)
Obhođaš, Jasmina; Sudac, Davorin; Valković, Vladivoj
2016-06-01
In order to perform Quality Assurance/Quality Control (QA/QC) procedures for a system dedicated to the neutron interrogation of objects for the presence of threat materials one needs to perform measurements of reference materials (RM) i.e. simulants having the same (or similar) atomic ratios as real materials. It is well known that explosives, drugs, and various other benign materials, contain chemical elements such as hydrogen, oxygen, carbon and nitrogen in distinctly different quantities. For example, a high carbon-to-oxygen ratio (C/O) is characteristic of drugs. Explosives can be differentiated by measurement of both (C/O) and nitrogen-to-oxygen (N/O) ratios. The C/N ratio of the chemical warfare agents, coupled with the measurement of elements such as fluorine and phosphorus, clearly differentiate them from the conventional explosives. Here we present the RM preparation, calibration procedure and correlations attained between theoretical values and experimentally obtained results in laboratory conditions for C/O and N/C ratios of prepared hexogen (RDX), TNT, DLM2, TATP, cocaine, heroin, yperite, tetranitromethane, peroxide methylethylketone, nitromethane and ethyleneglycol dinitrate simulants. We have shown that analyses of the gamma ray spectra by using simple unfolding model developed for this purpose gave a nice agreement with the chemical formula of created simulants, thus the calibration quality was successfully tested.
Radiofrequency Ablation of Lung Tumors
... the procedure. top of page What does the equipment look like? In this procedure, computed tomography (CT) ... electrical generator and grounding pads are used. Radiofrequency equipment There are two types of needle electrodes: simple ...
Radiofrequency Ablation of Liver Tumors
... the procedure. top of page What does the equipment look like? The equipment used in this procedure ... and grounding pads may also be used. Radiofrequency equipment There are two types of needle electrodes: simple ...
Busse, Harald; Riedel, Tim; Garnov, Nikita; Thörmer, Gregor; Kahn, Thomas; Moche, Michael
2015-01-01
Objectives MRI is of great clinical utility for the guidance of special diagnostic and therapeutic interventions. The majority of such procedures are performed iteratively ("in-and-out") in standard, closed-bore MRI systems with control imaging inside the bore and needle adjustments outside the bore. The fundamental limitations of such an approach have led to the development of various assistance techniques, from simple guidance tools to advanced navigation systems. The purpose of this work was to thoroughly assess the targeting accuracy, workflow and usability of a clinical add-on navigation solution on 240 simulated biopsies by different medical operators. Methods Navigation relied on a virtual 3D MRI scene with real-time overlay of the optically tracked biopsy needle. Smart reference markers on a freely adjustable arm ensured proper registration. Twenty-four operators – attending (AR) and resident radiologists (RR) as well as medical students (MS) – performed well-controlled biopsies of 10 embedded model targets (mean diameter: 8.5 mm, insertion depths: 17-76 mm). Targeting accuracy, procedure times and 13 Likert scores on system performance were determined (strong agreement: 5.0). Results Differences in diagnostic success rates (AR: 93%, RR: 88%, MS: 81%) were not significant. In contrast, between-group differences in biopsy times (AR: 4:15, RR: 4:40, MS: 5:06 min:sec) differed significantly (p<0.01). Mean overall rating was 4.2. The average operator would use the system again (4.8) and stated that the outcome justifies the extra effort (4.4). Lowest agreement was reported for the robustness against external perturbations (2.8). Conclusions The described combination of optical tracking technology with an automatic MRI registration appears to be sufficiently accurate for instrument guidance in a standard (closed-bore) MRI environment. High targeting accuracy and usability was demonstrated on a relatively large number of procedures and operators. Between groups with different expertise there were significant differences in experimental procedure times but not in the number of successful biopsies. PMID:26222443
Sánchez, Benjamín J; Pérez-Correa, José R; Agosin, Eduardo
2014-09-01
Dynamic flux balance analysis (dFBA) has been widely employed in metabolic engineering to predict the effect of genetic modifications and environmental conditions in the cell׳s metabolism during dynamic cultures. However, the importance of the model parameters used in these methodologies has not been properly addressed. Here, we present a novel and simple procedure to identify dFBA parameters that are relevant for model calibration. The procedure uses metaheuristic optimization and pre/post-regression diagnostics, fixing iteratively the model parameters that do not have a significant role. We evaluated this protocol in a Saccharomyces cerevisiae dFBA framework calibrated for aerobic fed-batch and anaerobic batch cultivations. The model structures achieved have only significant, sensitive and uncorrelated parameters and are able to calibrate different experimental data. We show that consumption, suboptimal growth and production rates are more useful for calibrating dynamic S. cerevisiae metabolic models than Boolean gene expression rules, biomass requirements and ATP maintenance. Copyright © 2014 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.
Monou, M; Kythreotou, N; Fatta, D; Smith, S R
2009-02-01
Small-scale experimental investigations were undertaken on the anaerobic digestion (AD) and codigestion of livestock waste and industrial biowastes. A simple procedure was developed to rapidly determine the suitability of wastes for digestion. The experiment was split into two phases; initially, the seed (digested brewery waste) was replaced by the test waste over a period of 5 days. During the second phase, the test waste was incubated and monitored for methanogenesis. Dairy cattle slurry was the most efficient co-substrate which, when codigested with pig slurry in an equal ratio achieved volatile solids destruction of 32%, CH(4) production rate of 97.4 ml d(-1), maximum CH(4) content of 61.6% and total gas yield of 2229 ml after 529 h. High fat content wastes were unsuitable for AD due to low pH value and because the dominant microbial reaction was fermentation. Codigestion was investigated to overcome any inhibitions; however, dairy cattle slurry, abattoir wastewater and NaOH additions did not lead to methanogenesis. Treating these wastes by AD is feasible but without CH(4) production.
A porous media theory for characterization of membrane blood oxygenation devices
NASA Astrophysics Data System (ADS)
Sano, Yoshihiko; Adachi, Jun; Nakayama, Akira
2013-07-01
A porous media theory has been proposed to characterize oxygen transport processes associated with membrane blood oxygenation devices. For the first time, a rigorous mathematical procedure based a volume averaging procedure has been presented to derive a complete set of the governing equations for the blood flow field and oxygen concentration field. As a first step towards a complete three-dimensional numerical analysis, one-dimensional steady case is considered to model typical membrane blood oxygenator scenarios, and to validate the derived equations. The relative magnitudes of oxygen transport terms are made clear, introducing a dimensionless parameter which measures the distance the oxygen gas travels to dissolve in the blood as compared with the blood dispersion length. This dimensionless number is found so large that the oxygen diffusion term can be neglected in most cases. A simple linear relationship between the blood flow rate and total oxygen transfer rate is found for oxygenators with sufficiently large membrane surface areas. Comparison of the one-dimensional analytic results and available experimental data reveals the soundness of the present analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Overton, J.H.; Jarabek, A.M.
1989-01-01
The U.S. EPA advocates the assessment of health-effects data and calculation of inhaled reference doses as benchmark values for gauging systemic toxicity to inhaled gases. The assessment often requires an inter- or intra-species dose extrapolation from no observed adverse effect level (NOAEL) exposure concentrations in animals to human equivalent NOAEL exposure concentrations. To achieve this, a dosimetric extrapolation procedure was developed based on the form or type of equations that describe the uptake and disposition of inhaled volatile organic compounds (VOCs) in physiologically-based pharmacokinetic (PB-PK) models. The procedure assumes allometric scaling of most physiological parameters and that the value ofmore » the time-integrated human arterial-blood concentration must be limited to no more than to that of experimental animals. The scaling assumption replaces the need for most parameter values and allows the derivation of a simple formula for dose extrapolation of VOCs that gives equivalent or more-conservative exposure concentrations values than those that would be obtained using a PB-PK model in which scaling was assumed.« less
A rational approach to predict and modulate stereolability of chiral alpha substituted ketones.
Cirilli, Roberto; Costi, Roberta; Di Santo, Roberto; Gasparrini, Francesco; La Torre, Francesco; Pierini, Marco; Siani, Gabriella
2009-01-01
An effective strategy to assess and modulate the stereolability of chiral alpha substituted ketones (C alpha SKs) is presented. The tendency of C alpha SKs to retain or change their configuration in water is analyzed as a function of thermodynamic proton-release attitude of alpha asymmetric atoms inside the structures by linear Brønsted correlations. A molecular modeling procedure was developed to analyze and suggest chemical modifications of C alpha SKs in view to obtain the desired grade of stereochemical stability. The approach was employed to predict the tendency to enantiomerize in water of two ketones (1 and 2) endowed with inhibitory activity against monoamine oxidases (MAOs) and the results were confirmed by experimental kinetics measurements performed in organic medium. As a demonstration of practical potentialities of the approach, four new structures, conceived as simple chemical modifications of 1 and 2, were designed to improve/reduce the stereostability grade of the starting anti-MAO ketones. The possibility to extend easily the procedure to other classes of C-H acids appears of interest.
Characterization of laser beam transmission through a High Density Polyethylene (HDPE) plate
NASA Astrophysics Data System (ADS)
Genna, S.; Leone, C.; Tagliaferri, V.
2017-02-01
Infrared (IR) light propagation in semicrystalline polymers involves mechanisms such as reflection, transmission, absorption and internal scattering. These different rates determine either the interaction mechanism, either the temperatures reached in the IR heating processes. Consequently, the knowledge of these rates is fundamental in the development of IR heating processes in order to avoid the polymer's damage and to increase the process energy efficiency. Aim of this work is to assess a simple procedure to determine the rates of absorbed, reflected, transmitted and scattered energy in the case of an unfilled High Density Polyethylene (HDPE) plate. Experimental tests were performed by exposing a HDPE plate, 3 mm in thickness, to a diode laser source, working at the fundamental wavelength of 975 nm. The transmitted power was measured by power meter, the reflected one by applying the Beer-Lambert law to sample of different thickness. IR thermal images were adopted to measure the absorbed ratio. The scattered ratio was measured by energetic balance, as difference between the incoming power and the other ratios. Finally, IR thermal images were adopted to measure the scattered ratio and to validate the procedure.
49 CFR 1141.1 - Procedures to calculate interest rates.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the portion of the year covered by the interest rate. A simple multiplication of the nominal rate by... 49 Transportation 8 2010-10-01 2010-10-01 false Procedures to calculate interest rates. 1141.1... TRANSPORTATION BOARD, DEPARTMENT OF TRANSPORTATION RULES OF PRACTICE PROCEDURES TO CALCULATE INTEREST RATES...
A Simple Illustration for the Need of Multiple Comparison Procedures
ERIC Educational Resources Information Center
Carter, Rickey E.
2010-01-01
Statistical adjustments to accommodate multiple comparisons are routinely covered in introductory statistical courses. The fundamental rationale for such adjustments, however, may not be readily understood. This article presents a simple illustration to help remedy this.
NASA Technical Reports Server (NTRS)
Rao, R. G. S.; Ulaby, F. T.
1977-01-01
The paper examines optimal sampling techniques for obtaining accurate spatial averages of soil moisture, at various depths and for cell sizes in the range 2.5-40 acres, with a minimum number of samples. Both simple random sampling and stratified sampling procedures are used to reach a set of recommended sample sizes for each depth and for each cell size. Major conclusions from statistical sampling test results are that (1) the number of samples required decreases with increasing depth; (2) when the total number of samples cannot be prespecified or the moisture in only one single layer is of interest, then a simple random sample procedure should be used which is based on the observed mean and SD for data from a single field; (3) when the total number of samples can be prespecified and the objective is to measure the soil moisture profile with depth, then stratified random sampling based on optimal allocation should be used; and (4) decreasing the sensor resolution cell size leads to fairly large decreases in samples sizes with stratified sampling procedures, whereas only a moderate decrease is obtained in simple random sampling procedures.
Bohnen, Jordan D; George, Brian C; Williams, Reed G; Schuller, Mary C; DaRosa, Debra A; Torbeck, Laura; Mullen, John T; Meyerson, Shari L; Auyang, Edward D; Chipman, Jeffrey G; Choi, Jennifer N; Choti, Michael A; Endean, Eric D; Foley, Eugene F; Mandell, Samuel P; Meier, Andreas H; Smink, Douglas S; Terhune, Kyla P; Wise, Paul E; Soper, Nathaniel J; Zwischenberger, Joseph B; Lillemoe, Keith D; Dunnington, Gary L; Fryer, Jonathan P
Intraoperative performance assessment of residents is of growing interest to trainees, faculty, and accreditors. Current approaches to collect such assessments are limited by low participation rates and long delays between procedure and evaluation. We deployed an innovative, smartphone-based tool, SIMPL (System for Improving and Measuring Procedural Learning), to make real-time intraoperative performance assessment feasible for every case in which surgical trainees participate, and hypothesized that SIMPL could be feasibly integrated into surgical training programs. Between September 1, 2015 and February 29, 2016, 15 U.S. general surgery residency programs were enrolled in an institutional review board-approved trial. SIMPL was made available after 70% of faculty and residents completed a 1-hour training session. Descriptive and univariate statistics analyzed multiple dimensions of feasibility, including training rates, volume of assessments, response rates/times, and dictation rates. The 20 most active residents and attendings were evaluated in greater detail. A total of 90% of eligible users (1267/1412) completed training. Further, 13/15 programs began using SIMPL. Totally, 6024 assessments were completed by 254 categorical general surgery residents (n = 3555 assessments) and 259 attendings (n = 2469 assessments), and 3762 unique operations were assessed. There was significant heterogeneity in participation within and between programs. Mean percentage (range) of users who completed ≥1, 5, and 20 assessments were 62% (21%-96%), 34% (5%-75%), and 10% (0%-32%) across all programs, and 96%, 75%, and 32% in the most active program. Overall, response rate was 70%, dictation rate was 24%, and mean response time was 12 hours. Assessments increased from 357 (September 2015) to 1146 (February 2016). The 20 most active residents each received mean 46 assessments by 10 attendings for 20 different procedures. SIMPL can be feasibly integrated into surgical training programs to enhance the frequency and timeliness of intraoperative performance assessment. We believe SIMPL could help facilitate a national competency-based surgical training system, although local and systemic challenges still need to be addressed. Copyright © 2016. Published by Elsevier Inc.
Using Three-Dimensional Printing to Fabricate a Tubing Connector for Dilation and Evacuation.
Stitely, Michael L; Paterson, Helen
2016-02-01
This is a proof-of-concept study to show that simple instrumentation problems encountered in surgery can be solved by fabricating devices using a three-dimensional printer. The device used in the study is a simple tubing connector fashioned to connect two segments of suction tubing used in a surgical procedure where no commercially available product for this use is available through our usual suppliers in New Zealand. A cylindrical tubing connector was designed using three-dimensional printing design software. The tubing connector was fabricated using the Makerbot Replicator 2X three-dimensional printer. The connector was used in 15 second-trimester dilation and evacuation procedures. Data forms were completed by the primary operating surgeon. Descriptive statistics were used with the expectation that the device would function as intended in all cases. The three-dimensional printed tubing connector functioned as intended in all 15 instances. Commercially available three-dimensional printing technology can be used to overcome simple instrumentation problems encountered during gynecologic surgical procedures.
Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum.
Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing
2014-05-01
Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of P. falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8-24 h followed by routine culture. When cultures with 27-60% of ring stage were synchronized using this procedure, 70-93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. Copyright © 2014 Elsevier Inc. All rights reserved.
Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum
Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M.; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing
2014-01-01
Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of Plasmodium falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8–24 h followed by routine culture. When cultures with 27–60% of ring stage were synchronized using this procedure, 70–93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. PMID:24632190
NASA Astrophysics Data System (ADS)
Campbell, J.; Dean, J.; Clyne, T. W.
2017-02-01
This study concerns a commonly-used procedure for evaluating the steady state creep stress exponent, n, from indentation data. The procedure involves monitoring the indenter displacement history under constant load and making the assumption that, once its velocity has stabilised, the system is in a quasi-steady state, with stage II creep dominating the behaviour. The stress and strain fields under the indenter are represented by "equivalent stress" and "equivalent strain rate" values. The estimate of n is then obtained as the gradient of a plot of the logarithm of the equivalent strain rate against the logarithm of the equivalent stress. Concerns have, however, been expressed about the reliability of this procedure, and indeed it has already been shown to be fundamentally flawed. In the present paper, it is demonstrated, using a very simple analysis, that, for a genuinely stable velocity, the procedure always leads to the same, constant value for n (either 1.0 or 0.5, depending on whether the tip shape is spherical or self-similar). This occurs irrespective of the value of the measured velocity, or indeed of any creep characteristic of the material. It is now clear that previously-measured values of n, obtained using this procedure, have varied in a more or less random fashion, depending on the functional form chosen to represent the displacement-time history and the experimental variables (tip shape and size, penetration depth, etc.), with little or no sensitivity to the true value of n.
Wijemanne, Nimanthi; Soysa, Preethi; Wijesundara, Sulochana; Perera, Hemamali
2018-01-01
Uric acid and hypoxanthine are produced in the catabolism of purine. Abnormal urinary levels of these products are associated with many diseases and therefore it is necessary to have a simple and rapid method to detect them. Hence, we report a simple reverse phase high performance liquid chromatography (HPLC/UV) technique, developed and validated for simultaneous analysis of uric acid, hypoxanthine, and creatinine in human urine. Urine was diluted appropriately and eluted with C-18 column 100 mm × 4.6 mm with a C-18 precolumn 25 mm × 4.6 mm in series. Potassium phosphate buffer (20 mM, pH 7.25) at a flow rate of 0.40 mL/min was employed as the solvent and peaks were detected at 235 nm. Tyrosine was used as the internal standard. The experimental conditions offered a good separation of analytes without interference of endogenous substances. The calibration curves were linear for all test compounds with a regression coefficient, r 2 > 0.99. Uric acid, creatinine, tyrosine, and hypoxanthine were eluted at 5.2, 6.1, 7.2, and 8.3 min, respectively. Intraday and interday variability were less than 4.6% for all the analytes investigated and the recovery ranged from 98 to 102%. The proposed HPLC procedure is a simple, rapid, and low cost method with high accuracy with minimum use of organic solvents. This method was successfully applied for the determination of creatinine, hypoxanthine, and uric acid in human urine.
NASA Technical Reports Server (NTRS)
Partridge, William P.; Laurendeau, Normand M.
1997-01-01
We have experimentally assessed the quantitative nature of planar laser-induced fluorescence (PLIF) measurements of NO concentration in a unique atmospheric pressure, laminar, axial inverse diffusion flame (IDF). The PLIF measurements were assessed relative to a two-dimensional array of separate laser saturated fluorescence (LSF) measurements. We demonstrated and evaluated several experimentally-based procedures for enhancing the quantitative nature of PLIF concentration images. Because these experimentally-based PLIF correction schemes require only the ability to make PLIF and LSF measurements, they produce a more broadly applicable PLIF diagnostic compared to numerically-based correction schemes. We experimentally assessed the influence of interferences on both narrow-band and broad-band fluorescence measurements at atmospheric and high pressures. Optimum excitation and detection schemes were determined for the LSF and PLIF measurements. Single-input and multiple-input, experimentally-based PLIF enhancement procedures were developed for application in test environments with both negligible and significant quench-dependent error gradients. Each experimentally-based procedure provides an enhancement of approximately 50% in the quantitative nature of the PLIF measurements, and results in concentration images nominally as quantitative as LSF point measurements. These correction procedures can be applied to other species, including radicals, for which no experimental data are available from which to implement numerically-based PLIF enhancement procedures.
Feasibility of Air Levitated Surface Stage for Lithography Tool
NASA Astrophysics Data System (ADS)
Tanaka, Keiichi
The application of light-weight drive technology into the lithography stage has been the current state of art because of minimization of power loss. The purpose of this article is to point out the so-called, "surface stage" which is composed of Lorentz forced 3 DOF (Degree Of Freedom) planar motor (x, y and theta z), air levitation (bearing) system and motor cooling system, is the most balanced concept for the next generation lithography through the verification of each component by manufacturing simple parts and test stand. This paper presents the design method and procedure, and experimental results of the air levitated surface stage which was conducted several years ago, however the author is convinced that the results are enough to adapt various developments of precision machining tool.
NASA Astrophysics Data System (ADS)
Bianco, Vincenzo; Nardini, Sergio; Manca, Oronzio
2011-12-01
In this article, developing turbulent forced convection flow of a water-Al2O3 nanofluid in a square tube, subjected to constant and uniform wall heat flux, is numerically investigated. The mixture model is employed to simulate the nanofluid flow and the investigation is accomplished for particles size equal to 38 nm. An entropy generation analysis is also proposed in order to find the optimal working condition for the given geometry under given boundary conditions. A simple analytical procedure is proposed to evaluate the entropy generation and its results are compared with the numerical calculations, showing a very good agreement. A comparison of the resulting Nusselt numbers with experimental correlations available in literature is accomplished. To minimize entropy generation, the optimal Reynolds number is determined.
NASA Technical Reports Server (NTRS)
Abbey, Craig K.; Eckstein, Miguel P.
2002-01-01
We consider estimation and statistical hypothesis testing on classification images obtained from the two-alternative forced-choice experimental paradigm. We begin with a probabilistic model of task performance for simple forced-choice detection and discrimination tasks. Particular attention is paid to general linear filter models because these models lead to a direct interpretation of the classification image as an estimate of the filter weights. We then describe an estimation procedure for obtaining classification images from observer data. A number of statistical tests are presented for testing various hypotheses from classification images based on some more compact set of features derived from them. As an example of how the methods we describe can be used, we present a case study investigating detection of a Gaussian bump profile.
Optimal cooperative control synthesis of active displays
NASA Technical Reports Server (NTRS)
Garg, S.; Schmidt, D. K.
1985-01-01
A technique is developed that is intended to provide a systematic approach to synthesizing display augmentation for optimal manual control in complex, closed-loop tasks. A cooperative control synthesis technique, previously developed to design pilot-optimal control augmentation for the plant, is extended to incorporate the simultaneous design of performance enhancing displays. The technique utilizes an optimal control model of the man in the loop. It is applied to the design of a quickening control law for a display and a simple K/s(2) plant, and then to an F-15 type aircraft in a multi-channel task. Utilizing the closed loop modeling and analysis procedures, the results from the display design algorithm are evaluated and an analytical validation is performed. Experimental validation is recommended for future efforts.
An efficient algorithm for automatic phase correction of NMR spectra based on entropy minimization
NASA Astrophysics Data System (ADS)
Chen, Li; Weng, Zhiqiang; Goh, LaiYoong; Garland, Marc
2002-09-01
A new algorithm for automatic phase correction of NMR spectra based on entropy minimization is proposed. The optimal zero-order and first-order phase corrections for a NMR spectrum are determined by minimizing entropy. The objective function is constructed using a Shannon-type information entropy measure. Entropy is defined as the normalized derivative of the NMR spectral data. The algorithm has been successfully applied to experimental 1H NMR spectra. The results of automatic phase correction are found to be comparable to, or perhaps better than, manual phase correction. The advantages of this automatic phase correction algorithm include its simple mathematical basis and the straightforward, reproducible, and efficient optimization procedure. The algorithm is implemented in the Matlab program ACME—Automated phase Correction based on Minimization of Entropy.
Robust control of the DC-DC boost converter based on the uncertainty and disturbance estimator
NASA Astrophysics Data System (ADS)
Oucheriah, Said
2017-11-01
In this paper, a robust non-linear controller based on the uncertainty and disturbance estimator (UDE) scheme is successfully developed and implemented for the output voltage regulation of the DC-DC boost converter. System uncertainties, external disturbances and unknown non-linear dynamics are lumped as a signal that is accurately estimated using a low-pass filter and their effects are cancelled by the controller. This methodology forms the basis of the UDE-based controller. A simple procedure is also developed that systematically determines the parameters of the controller to meet certain specifications. Using simulation, the effectiveness of the proposed controller is compared against the sliding-mode control (SMC). Experimental tests also show that the proposed controller is robust to system uncertainties, large input and load perturbations.
NASA Astrophysics Data System (ADS)
Li, Jie; Zippilli, Stefano; Zhang, Jing; Vitali, David
2016-05-01
Collapse models postulate the existence of intrinsic noise which modifies quantum mechanics and is responsible for the emergence of macroscopic classicality. Assessing the validity of these models is extremely challenging because it is nontrivial to discriminate unambiguously their presence in experiments where other hardly controllable sources of noise compete to the overall decoherence. Here we provide a simple procedure that is able to probe the hypothetical presence of the collapse noise with a levitated nanosphere in a Fabry-Pérot cavity. We show that the stationary state of the system is particularly sensitive, under specific experimental conditions, to the interplay between the trapping frequency, the cavity size, and the momentum diffusion induced by the collapse models, allowing one to detect them even in the presence of standard environmental noises.
Uniform, luminescent Eu:LuF3 nanoparticles
NASA Astrophysics Data System (ADS)
Becerro, Ana I.; Gonzalez-Mancebo, Daniel; Ocaña, Manuel
2015-01-01
A simple procedure for the synthesis of orthorhombic, uniform, LuF3 particles with two different morphologies (rhombus- and cocoon-like) and nanometer and sub-micrometer size, respectively, is reported. The method consists in the aging, at 120 °C for 2 h, a solution containing [BMIM]BF4 ionic liquid (0.5 mL) and lutetium acetate (in the case of the rhombi) or lutetium nitrate (in the case of the cocoons) (0.02 M) in ethylene glycol (total volume 10 mL). This synthesis method was also adequate for the synthesis of Eu3+-doped LuF3 particles of both morphologies, whose luminescence properties were investigated in detail. The experimental observations reported herein suggest that these materials are suitable phosphors for optoelectronic as well as in vitro biotechnological applications.
Asymmetrically dominated choice problems, the isolation hypothesis and random incentive mechanisms.
Cox, James C; Sadiraj, Vjollca; Schmidt, Ulrich
2014-01-01
This paper presents an experimental study of the random incentive mechanisms which are a standard procedure in economic and psychological experiments. Random incentive mechanisms have several advantages but are incentive-compatible only if responses to the single tasks are independent. This is true if either the independence axiom of expected utility theory or the isolation hypothesis of prospect theory holds. We present a simple test of this in the context of choice under risk. In the baseline (one task) treatment we observe risk behavior in a given choice problem. We show that by integrating a second, asymmetrically dominated choice problem in a random incentive mechanism risk behavior can be manipulated systematically. This implies that the isolation hypothesis is violated and the random incentive mechanism does not elicit true preferences in our example.
A laboratory information management system for DNA barcoding workflows.
Vu, Thuy Duong; Eberhardt, Ursula; Szöke, Szániszló; Groenewald, Marizeth; Robert, Vincent
2012-07-01
This paper presents a laboratory information management system for DNA sequences (LIMS) created and based on the needs of a DNA barcoding project at the CBS-KNAW Fungal Biodiversity Centre (Utrecht, the Netherlands). DNA barcoding is a global initiative for species identification through simple DNA sequence markers. We aim at generating barcode data for all strains (or specimens) included in the collection (currently ca. 80 k). The LIMS has been developed to better manage large amounts of sequence data and to keep track of the whole experimental procedure. The system has allowed us to classify strains more efficiently as the quality of sequence data has improved, and as a result, up-to-date taxonomic names have been given to strains and more accurate correlation analyses have been carried out.
Compositions in II-Flat. A Prelude to Pythagoras
ERIC Educational Resources Information Center
Callagy, J. J.
1971-01-01
This article shows how simple instruments may be used to construct angles of certain measures and applies this procedure to more detailed problems. A proof of the Pythagorean Theorem is given using these procedures. (CT)
Female genital mutilation reversal: a general approach.
Anand, Mallika; Stanhope, Todd J; Occhino, John A
2014-07-01
Female genital mutilation (FGM) is a violation of human rights; yet, more than 100 million females are estimated to have undergone the procedure worldwide. There is an increased need for physician education in treating FGM. Female pelvic surgeons have a unique opportunity to treat this population of patients. Here, we depict the classification of FGM and a general approach to FGM reversal. We specifically address the procedure of type III FGM reversal, or defibulation. In this video, we first highlight the importance of the problem of FGM. Next, we present the classification of FGM using an original, simple, schematic diagram highlighting they key anatomic structures involved in the four types of FGM. We then present a simple case of reversal of type III FGM, a procedure also known as defibulation. After depicting the surgical procedure, we discuss clinical results and summarize key principles of the defibulation procedure. Our patient was a 25-year-old woman who had undergone type III FGM as a child in Somalia. She desired restoration of vaginal function. We performed a reversal, and her postoperative course was uncomplicated. By 6 weeks postoperatively, she was able to engage in sexual intercourse without dyspareunia. FGM is a problem at the doorsteps of female pelvic medicine and reconstructive surgery. Our video demonstrates a basic surgical approach that can be applied to simple cases of type III FGM presenting to the female pelvic surgeon.
NASA Astrophysics Data System (ADS)
Robin, C. M.
2005-12-01
Many fluid mechanical experiments with direct applications to Earth Science are performed with sugary syrups using conceptually straightforward procedures. Corn syrup has indeed proven to be a godsend for those studying convection and related non-linear phenomena. In addition, however, it gives experimentalists a deep physical intuition for the interior workings of hot planets. The basic concepts behind plate tectonics and mantle convection are not difficult; indeed, although they may not be aware of it, most students probably have a basic intuitive understanding of fluid mechanics gained in their daily life. However, the large size and long time scale of geophysical processes may be quite intimidating to young students. Even a simple geophysical experiment requires a complicated array of coolers, heaters and measuring and recording equipment. It is of interest to introduce students to the geodynamical concepts that can be visualized in a high-tech lab using familiar processes and equipment. Using a homemade apparatus and grocery store supplies, I propose using a 'Stove-top Earth pecan pie' to introduce simple geodynamic concepts to middle- and high-school students. The initially cold syrup heats up and the pecans begin to float (continent formation), the syrup begins to convect (mantle convection), and convection slows down after the heat is removed (secular cooling). Even Wilson cycles can be simulated by moving the pan to one side or the other of the stovetop or heating element. The activity formally introduces students to convection and its application to the earth, and makes them think about plate motion, heat transfer, scaling, and experimental procedures. As an added bonus, they can eat their experiments after recess!
The Behavioral Economics of Choice and Interval Timing
Jozefowiez, J.; Staddon, J. E. R.; Cerutti, D. T.
2009-01-01
We propose a simple behavioral economic model (BEM) describing how reinforcement and interval timing interact. The model assumes a Weber-law-compliant logarithmic representation of time. Associated with each represented time value are the payoffs that have been obtained for each possible response. At a given real time, the response with the highest payoff is emitted. The model accounts for a wide range of data from procedures such as simple bisection, metacognition in animals, economic effects in free-operant psychophysical procedures and paradoxical choice in double-bisection procedures. Although it assumes logarithmic time representation, it can also account for data from the time-left procedure usually cited in support of linear time representation. It encounters some difficulties in complex free-operant choice procedures, such as concurrent mixed fixed-interval schedules as well as some of the data on double bisection, that may involve additional processes. Overall, BEM provides a theoretical framework for understanding how reinforcement and interval timing work together to determine choice between temporally differentiated reinforcers. PMID:19618985
Procedure for estimating orbital debris risks
NASA Technical Reports Server (NTRS)
Crafts, J. L.; Lindberg, J. P.
1985-01-01
A procedure for estimating the potential orbital debris risk to the world's populace from payloads or spent stages left in orbit on future missions is presented. This approach provides a consistent, but simple, procedure to assess the risk due to random reentry with an adequate accuracy level for making programmatic decisions on planned low Earth orbit missions.
Modelling the complete operation of a free-piston shock tunnel for a low enthalpy condition
NASA Astrophysics Data System (ADS)
McGilvray, M.; Dann, A. G.; Jacobs, P. A.
2013-07-01
Only a limited number of free-stream flow properties can be measured in hypersonic impulse facilities at the nozzle exit. This poses challenges for experimenters when subsequently analysing experimental data obtained from these facilities. Typically in a reflected shock tunnel, a simple analysis that requires small amounts of computational resources is used to calculate quasi-steady gas properties. This simple analysis requires initial fill conditions and experimental measurements in analytical calculations of each major flow process, using forward coupling with minor corrections to include processes that are not directly modeled. However, this simplistic approach leads to an unknown level of discrepancy to the true flow properties. To explore the simple modelling techniques accuracy, this paper details the use of transient one and two-dimensional numerical simulations of a complete facility to obtain more refined free-stream flow properties from a free-piston reflected shock tunnel operating at low-enthalpy conditions. These calculations were verified by comparison to experimental data obtained from the facility. For the condition and facility investigated, the test conditions at nozzle exit produced with the simple modelling technique agree with the time and space averaged results from the complete facility calculations to within the accuracy of the experimental measurements.
The Effect of Massage on Anticipatory Anxiety and Procedural Pain in Patients with Burn Injury.
Najafi Ghezeljeh, Tahereh; Mohades Ardebili, Fatimah; Rafii, Forough; Manafi, Farzad
2017-01-01
Pain related to burn injuries is one of the most troublesome pain intensity. This study aimed to investigate the effect of massage on anticipatory anxiety, procedural pain intensity, vital signs and relaxation level of patients with burn injury. In this quasi-experimental study, through convenience sampling, 60 hospitalized adult burn patients were selected from a specialized burn and reconstructive hospital. Subjects were assigned to massage and control groups through simple randomization. Massage was offered by using non aromatic oil about 10-15 minutes before wound care on intact part of the body once a day for 20 minutes on patients' bedside for 3 consecutive days. In the 3 days, the control group did not received any massage and were asked to stay at bed. Demographic and clinical characteristics and vital signs, Visual Analogue Scale and the Persian version of Burn Specific Pain Anxiety Scale were used to determine baseline and procedural pain, anxiety and relaxation levels and anticipatory anxiety. No significant difference was noted between mean score of pain intensity, anxiety and relaxation level, and vital signs in massage and control groups after intervention following wound care. In massage and control groups, there was no significant differences between mean scores of anticipatory anxiety before and after intervention. There was no significant difference between the mean scores of anticipatory anxiety in massage and control groups after intervention prior wound care. Massage was shown not to have any effect on anticipatory anxiety and procedural pain.
Discharge characteristics of embankment-shaped weirs
Kindsvater, Carl E.
1964-01-01
An embankment-shaped weir is an embankment overtopped by flood waters. Among the engineering problems frequently resulting from. this occurrence is the need to compute the peak discharge from postflood yield observations. The research described in this. report was concerned with the theoretical and experimental bases for the computation procedure. The research had two main objectives. One was to determine the relationship between embankment form and roughness and some of the more important discharge characteristics. The second was to define, theoretically and experimentally, the relationship between free-flow discharge and the boundary layer on the roadway. The first objective was accomplished with the experimental determination of coefficients of discharge and other significant flow characteristics for a variety of boundary and flow conditions. The second objective was accomplished with the development and experimental verification of a discharge equation which involved the boundary layer displacement thickness. This phase of the research included a general investigation of boundary layer growth on the roadway. It is included that both free- and submerged-flow discharge are virtually independent of the influence of embankment shape and relative height. The influence of boundary resistance is appreciable only for smaller heads. The most practical solution for discharge is one which is based on. the simple weir equation and experimentally determined coefficients. A completely analytical equation of discharge is impractical. The report contains the results of 936 experiments on the discharge characteristics of 17 different models; plus 106 boundary-layer velocity traverses on 4 different models. The data are summarized in both graphical and tabular form.
de Abreu, Igor Renato Louro Bruno; Abrão, Fernando Conrado; Silva, Alessandra Rodrigues; Corrêa, Larissa Teresa Cirera; Younes, Riad Nain
2015-05-01
Currently, there is a tendency to perform surgical procedures via laparoscopic or thoracoscopic access. However, even with the impressive technological advancement in surgical materials, such as improvement in quality of monitors, light sources, and optical fibers, surgeons have to face simple problems that can greatly hinder surgery by video. One is the formation of "fog" or residue buildup on the lens, causing decreased visibility. Intracavitary techniques for cleaning surgical optics and preventing fog formation have been described; however, some of these techniques employ the use of expensive and complex devices designed solely for this purpose. Moreover, these techniques allow the cleaning of surgical optics when they becomes dirty, which does not prevent the accumulation of residue in the optics. To solve this problem we have designed a device that allows cleaning the optics with no surgical stops and prevents the fogging and residue accumulation. The objective of this study is to evaluate through experimental testing the effectiveness of a simple device that prevents the accumulation of residue and fogging of optics used in surgical procedures performed through thoracoscopic or laparoscopic access. Ex-vivo experiments were performed simulating the conditions of residue presence in surgical optics during a video surgery. The experiment consists in immersing the optics and catheter set connected to the IV line with crystalloid solution in three types of materials: blood, blood plus fat solution, and 200 mL of distilled water and 1 vial of methylene blue. The optics coupled to the device were immersed in 200 mL of each type of residue, repeating each immersion 10 times for each distinct residue for both thirty and zero degrees optics, totaling 420 experiments. A success rate of 98.1% was observed after the experiments, in these cases the device was able to clean and prevent the residue accumulation in the optics.
Richter, S. Helene; Garner, Joseph P.; Zipser, Benjamin; Lewejohann, Lars; Sachser, Norbert; Touma, Chadi; Schindler, Britta; Chourbaji, Sabine; Brandwein, Christiane; Gass, Peter; van Stipdonk, Niek; van der Harst, Johanneke; Spruijt, Berry; Võikar, Vootele; Wolfer, David P.; Würbel, Hanno
2011-01-01
In animal experiments, animals, husbandry and test procedures are traditionally standardized to maximize test sensitivity and minimize animal use, assuming that this will also guarantee reproducibility. However, by reducing within-experiment variation, standardization may limit inference to the specific experimental conditions. Indeed, we have recently shown in mice that standardization may generate spurious results in behavioral tests, accounting for poor reproducibility, and that this can be avoided by population heterogenization through systematic variation of experimental conditions. Here, we examined whether a simple form of heterogenization effectively improves reproducibility of test results in a multi-laboratory situation. Each of six laboratories independently ordered 64 female mice of two inbred strains (C57BL/6NCrl, DBA/2NCrl) and examined them for strain differences in five commonly used behavioral tests under two different experimental designs. In the standardized design, experimental conditions were standardized as much as possible in each laboratory, while they were systematically varied with respect to the animals' test age and cage enrichment in the heterogenized design. Although heterogenization tended to improve reproducibility by increasing within-experiment variation relative to between-experiment variation, the effect was too weak to account for the large variation between laboratories. However, our findings confirm the potential of systematic heterogenization for improving reproducibility of animal experiments and highlight the need for effective and practicable heterogenization strategies. PMID:21305027
Radiation/Catalytic Augmented Combustion.
1984-05-01
interest to compare the experimental results for the solid bluff body with a thuoretical result. Using simple argtinieiiLs from fluid mechanics " one...responsibility through completion. Dr. A. E. Cerkanowlcz assisted in writing this final report. Experimental studies on catalytic augmented combustion...as well as with other combustion species, lead to ignition and sustained combustion via chain reactions. Simple combustion enhancement without
Experimental Evaluation of the Drag Coefficient of Water Rockets by a Simple Free-Fall Test
ERIC Educational Resources Information Center
Barrio-Perotti, R.; Blanco-Marigorta, E. Arguelles-Diaz, K.; Fernandez-Oro, J.
2009-01-01
The flight trajectory of a water rocket can be reasonably calculated if the magnitude of the drag coefficient is known. The experimental determination of this coefficient with enough precision is usually quite difficult, but in this paper we propose a simple free-fall experiment for undergraduate students to reasonably estimate the drag…
Wotman, Michael; Levinger, Joshua; Leung, Lillian; Kallush, Aron; Mauer, Elizabeth
2017-01-01
Background Preoperative anxiety is a common problem in hospitals and other health care centers. This emotional state has been shown to negatively impact patient satisfaction and outcomes. Aromatherapy, the therapeutic use of essential oils extracted from aromatic plants, may offer a simple, low‐risk and cost‐effective method of managing preoperative anxiety. The purpose of this study was to evaluate the efficacy of lavender aromatherapy in reducing preoperative anxiety in ambulatory surgery patients undergoing procedures in general otolaryngology. Methods A prospective and controlled pilot study was conducted with 100 patients who were admitted to New York‐Presbyterian/Weill Cornell Medical Center for ambulatory surgery from January of 2015 to August of 2015. The subjects were allocated to two groups; the experimental group received inhalation lavender aromatherapy in the preoperative waiting area while the control group received standard nursing care. Both groups reported their anxiety with a visual analog scale (VAS) upon arriving to the preoperative waiting area and upon departure to the operating room. Results According to a Welch's two sample t‐test, the mean reduction in anxiety was statistically greater in the experimental group than the control group (p = 0.001). Conclusion Lavender aromatherapy reduced preoperative anxiety in ambulatory surgery patients. This effect was modest and possibly statistically significant. Future research is needed to confirm the clinical efficacy of lavender aromatherapy. Level of Evidence 2b PMID:29299520
Investigation to advance prediction techniques of the low-speed aerodynamics of V/STOL aircraft
NASA Technical Reports Server (NTRS)
Maskew, B.; Strash, D.; Nathman, J.; Dvorak, F. A.
1985-01-01
A computer program, VSAERO, has been applied to a number of V/STOL configurations with a view to advancing prediction techniques for the low-speed aerodynamic characteristics. The program couples a low-order panel method with surface streamline calculation and integral boundary layer procedures. The panel method--which uses piecewise constant source and doublet panels-includes an iterative procedure for wake shape and models boundary layer displacement effect using the source transpiration technique. Certain improvements to a basic vortex tube jet model were installed in the code prior to evaluation. Very promising results were obtained for surface pressures near a jet issuing at 90 deg from a flat plate. A solid core model was used in the initial part of the jet with a simple entrainment model. Preliminary representation of the downstream separation zone significantly improve the correlation. The program accurately predicted the pressure distribution inside the inlet on the Grumman 698-411 design at a range of flight conditions. Furthermore, coupled viscous/potential flow calculations gave very close correlation with experimentally determined operational boundaries dictated by the onset of separation inside the inlet. Experimentally observed degradation of these operational boundaries between nacelle-alone tests and tests on the full configuration were also indicated by the calculation. Application of the program to the General Dynamics STOL fighter design were equally encouraging. Very close agreement was observed between experiment and calculation for the effects of power on pressure distribution, lift and lift curve slope.
NASA Astrophysics Data System (ADS)
Pan, Feng; Ding, Xiaoxue; Launey, Kristina D.; Draayer, J. P.
2018-06-01
A simple and effective algebraic isospin projection procedure for constructing orthonormal basis vectors of irreducible representations of O (5) ⊃OT (3) ⊗ON (2) from those in the canonical O (5) ⊃ SUΛ (2) ⊗ SUI (2) basis is outlined. The expansion coefficients are components of null space vectors of the projection matrix with four nonzero elements in each row in general. Explicit formulae for evaluating OT (3)-reduced matrix elements of O (5) generators are derived.
An automated approach to the design of decision tree classifiers
NASA Technical Reports Server (NTRS)
Argentiero, P.; Chin, R.; Beaudet, P.
1982-01-01
An automated technique is presented for designing effective decision tree classifiers predicated only on a priori class statistics. The procedure relies on linear feature extractions and Bayes table look-up decision rules. Associated error matrices are computed and utilized to provide an optimal design of the decision tree at each so-called 'node'. A by-product of this procedure is a simple algorithm for computing the global probability of correct classification assuming the statistical independence of the decision rules. Attention is given to a more precise definition of decision tree classification, the mathematical details on the technique for automated decision tree design, and an example of a simple application of the procedure using class statistics acquired from an actual Landsat scene.
A Quantitative Review of Functional Analysis Procedures in Public School Settings
ERIC Educational Resources Information Center
Solnick, Mark D.; Ardoin, Scott P.
2010-01-01
Functional behavioral assessments can consist of indirect, descriptive and experimental procedures, such as a functional analysis. Although the research contains numerous examples demonstrating the effectiveness of functional analysis procedures, experimental conditions are often difficult to implement in classroom settings and analog conditions…
La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso
2015-10-01
Preclinical evaluation of the mechanical reliability of fixation devices is a mandatory activity before their introduction into market. There are two standardized protocols for preclinical testing of spinal implants. The American Society for Testing Materials (ASTM) recommends the F1717 standard, which describes a vertebrectomy condition that is relatively simple to implement, whereas the International Organization for Standardization (ISO) suggests the 12189 standard, which describes a more complex physiological anterior support-based setup. Moreover, ASTM F1717 is nowadays well established, whereas ISO 12189 has received little attention: A few studies tried to accurately describe the ISO experimental procedure through numeric models, but these studies totally neglect the recommended precompression step. This study aimed to build up a reliable, validated numeric model capable of describing the stress on the rods of a spinal fixator assembled according to ISO 12189 standard procedure. Such a model would more adequately represent the in vitro testing condition. This study used finite element (FE) simulations and experimental validation testing. An FE model of the ISO setup was built to calculate the stress on the rods. Simulation was validated by comparison with experimental strain gauges measurements. The same fixator has been previously virtually mounted in an L2-L4 FE model of the lumbar spine, and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between the FE predictions and experimental measurements is in good agreement, thus confirming the suitability of the FE method to evaluate the stresses in the device. The initial precompression induces a significant extension of the assembled construct. As the applied load increases, the initial extension is gradually compensated, so that at peak load the rods are bent in flexion: The final stress value predicted is thus reduced to about 50%, if compared with the previous model where the precompression was not considered. Neglecting the initial preload due to the assembly of the overall construct according to ISO 12189 standard could lead to an overestimation of the stress on the rods up to 50%. To correctly describe the state of stress on the posterior spinal fixator, tested according to the ISO procedure, it is important to take into account the initial preload due to the assembly of the overall construct. Copyright © 2015 Elsevier Inc. All rights reserved.
Estimation of descriptive statistics for multiply censored water quality data
Helsel, Dennis R.; Cohn, Timothy A.
1988-01-01
This paper extends the work of Gilliom and Helsel (1986) on procedures for estimating descriptive statistics of water quality data that contain “less than” observations. Previously, procedures were evaluated when only one detection limit was present. Here we investigate the performance of estimators for data that have multiple detection limits. Probability plotting and maximum likelihood methods perform substantially better than simple substitution procedures now commonly in use. Therefore simple substitution procedures (e.g., substitution of the detection limit) should be avoided. Probability plotting methods are more robust than maximum likelihood methods to misspecification of the parent distribution and their use should be encouraged in the typical situation where the parent distribution is unknown. When utilized correctly, less than values frequently contain nearly as much information for estimating population moments and quantiles as would the same observations had the detection limit been below them.
Virtual hybrid test control of sinuous crack
NASA Astrophysics Data System (ADS)
Jailin, Clément; Carpiuc, Andreea; Kazymyrenko, Kyrylo; Poncelet, Martin; Leclerc, Hugo; Hild, François; Roux, Stéphane
2017-05-01
The present study aims at proposing a new generation of experimental protocol for analysing crack propagation in quasi brittle materials. The boundary conditions are controlled in real-time to conform to a predefined crack path. Servo-control is achieved through a full-field measurement technique to determine the pre-set fracture path and a simple predictor model based on linear elastic fracture mechanics to prescribe the boundary conditions on the fly so that the actual crack path follows at best the predefined trajectory. The final goal is to identify, for instance, non-local damage models involving internal lengths. The validation of this novel procedure is performed via a virtual test-case based on an enriched damage model with an internal length scale, a prior chosen sinusoidal crack path and a concrete sample. Notwithstanding the fact that the predictor model selected for monitoring the test is a highly simplified picture of the targeted constitutive law, the proposed protocol exhibits a much improved sensitivity to the sought parameters such as internal lengths as assessed from the comparison with other available experimental tests.
Temperature dependence of ion transport: the compensated Arrhenius equation.
Petrowsky, Matt; Frech, Roger
2009-04-30
The temperature-dependent conductivity originating in a thermally activated process is often described by a simple Arrhenius expression. However, this expression provides a poor description of the data for organic liquid electrolytes and amorphous polymer electrolytes. Here, we write the temperature dependence of the conductivity as an Arrhenius expression and show that the experimentally observed non-Arrhenius behavior is due to the temperature dependence of the dielectric constant contained in the exponential prefactor. Scaling the experimentally measured conductivities to conductivities at a chosen reference temperature leads to a "compensated" Arrhenius equation that provides an excellent description of temperature-dependent conductivities. A plot of the prefactors as a function of the solvent dielectric constant results in a single master curve for each family of solvents. These data suggest that ion transport in these and related systems is governed by a single activated process differing only in the activation energy for each family of solvents. Connection is made to the shift factor used to describe electrical and mechanical relaxation in a wide range of phenomena, suggesting that this scaling procedure might have broad applications.
Sun, Shuangjiao; Long, Chanjuan; Tao, Chunyao; Meng, Sa; Deng, Biyang
2014-12-03
The paper describes a homemade ultrasonic microdialysis device coupled with capillary electrophoresis electrochemiluminescence (CE-ECL) for studying the interaction between human serum albumin (HSA) and trimetazidine dihydrochloride (TMZ). The time required for equilibrium by ultrasonic microdialysis was 45min, which was far less than that by traditional dialysis (240min). It took 80min to achieve the required combination equilibrium by normal incubation and only 20min by ultrasonic. Compared with traditional dialysis, the use of ultrasonic microdialysis simplified experimental procedures, shortened experimental time and saved consumption of sample. A simple, sensitive and selective determination of TMZ was developed using CE-ECL and the parameters that affected ECL intensity were optimized. Under the optimized conditions, the linear range of TMZ was from 0.075 to 80μmol/L (r(2)=0.9974). The detection limit was 26nmol/L with RSD of 2.8%. The number of binding sites and binding constant were 1.54 and 15.17L/mol, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jimenez, Santiago; Remacha, Pilar; Ballester, Javier
2008-03-15
In this paper the results of a complete set of devolatilization and combustion experiments performed with pulverized ({proportional_to}500 {mu}m) biomass in an entrained flow reactor under realistic combustion conditions are presented. The data obtained are used to derive the kinetic parameters that best fit the observed behaviors, according to a simple model of particle combustion (one-step devolatilization, apparent oxidation kinetics, thermally thin particles). The model is found to adequately reproduce the experimental trends regarding both volatile release and char oxidation rates for the range of particle sizes and combustion conditions explored. The experimental and numerical procedures, similar to those recentlymore » proposed for the combustion of pulverized coal [J. Ballester, S. Jimenez, Combust. Flame 142 (2005) 210-222], have been designed to derive the parameters required for the analysis of biomass combustion in practical pulverized fuel configurations and allow a reliable characterization of any finely pulverized biomass. Additionally, the results of a limited study on the release rate of nitrogen from the biomass particle along combustion are shown. (author)« less
Barone, Vincenzo; Bellina, Fabio; Biczysko, Malgorzata; Bloino, Julien; Fornaro, Teresa; Latouche, Camille; Lessi, Marco; Marianetti, Giulia; Minei, Pierpaolo; Panattoni, Alessandro; Pucci, Andrea
2015-10-28
The possibilities offered by organic fluorophores in the preparation of advanced plastic materials have been increased by designing novel alkynylimidazole dyes, featuring different push and pull groups. This new family of fluorescent dyes was synthesized by means of a one-pot sequential bromination-alkynylation of the heteroaromatic core, and their optical properties were investigated in tetrahydrofuran and in poly(methyl methacrylate). An efficient in silico pre-screening scheme was devised as consisting of a step-by-step procedure employing computational methodologies by simulation of electronic spectra within simple vertical energy and more sophisticated vibronic approaches. Such an approach was also extended to efficiently simulate one-photon absorption and emission spectra of the dyes in the polymer environment for their potential application in luminescent solar concentrators. Besides the specific applications of this novel material, the integration of computational and experimental techniques reported here provides an efficient protocol that can be applied to make a selection among similar dye candidates, which constitute the essential responsive part of those fluorescent plastic materials.
Quantitative Comparisons to Promote Inquiry in the Introductory Physics Lab
NASA Astrophysics Data System (ADS)
Holmes, N. G.; Bonn, D. A.
2015-09-01
In a recent report, the American Association of Physics Teachers has developed an updated set of recommendations for curriculum of undergraduate physics labs. This document focuses on six major themes: constructing knowledge, modeling, designing experiments, developing technical and practical laboratory skills, analyzing and visualizing data, and communicating physics. These themes all tie together as a set of practical skills in scientific measurement, analysis, and experimentation. In addition to teaching students how to use these skills, it is important for students to know when to use them so that they can use them autonomously. This requires, especially in the case of analytical skills, high levels of inquiry behaviors to reflect on data and iterate measurements, which students rarely do in lab experiments. Often, they perform lab experiments in a plug-and-chug frame, procedurally completing each activity with little to no sensemaking. An emphasis on obtaining true theoretical values or agreement on individual measurements also reinforces inauthentic behaviors such as retroactively inflating measurement uncertainties. This paper aims to offer a relatively simple pedagogical framework for engaging students authentically in experimentation and inquiry in physics labs.
Constrained Allocation Flux Balance Analysis
Mori, Matteo; Hwa, Terence; Martin, Olivier C.
2016-01-01
New experimental results on bacterial growth inspire a novel top-down approach to study cell metabolism, combining mass balance and proteomic constraints to extend and complement Flux Balance Analysis. We introduce here Constrained Allocation Flux Balance Analysis, CAFBA, in which the biosynthetic costs associated to growth are accounted for in an effective way through a single additional genome-wide constraint. Its roots lie in the experimentally observed pattern of proteome allocation for metabolic functions, allowing to bridge regulation and metabolism in a transparent way under the principle of growth-rate maximization. We provide a simple method to solve CAFBA efficiently and propose an “ensemble averaging” procedure to account for unknown protein costs. Applying this approach to modeling E. coli metabolism, we find that, as the growth rate increases, CAFBA solutions cross over from respiratory, growth-yield maximizing states (preferred at slow growth) to fermentative states with carbon overflow (preferred at fast growth). In addition, CAFBA allows for quantitatively accurate predictions on the rate of acetate excretion and growth yield based on only 3 parameters determined by empirical growth laws. PMID:27355325
Pixel-based parametric source depth map for Cerenkov luminescence imaging
NASA Astrophysics Data System (ADS)
Altabella, L.; Boschi, F.; Spinelli, A. E.
2016-01-01
Optical tomography represents a challenging problem in optical imaging because of the intrinsically ill-posed inverse problem due to photon diffusion. Cerenkov luminescence tomography (CLT) for optical photons produced in tissues by several radionuclides (i.e.: 32P, 18F, 90Y), has been investigated using both 3D multispectral approach and multiviews methods. Difficult in convergence of 3D algorithms can discourage to use this technique to have information of depth and intensity of source. For these reasons, we developed a faster 2D corrected approach based on multispectral acquisitions, to obtain source depth and its intensity using a pixel-based fitting of source intensity. Monte Carlo simulations and experimental data were used to develop and validate the method to obtain the parametric map of source depth. With this approach we obtain parametric source depth maps with a precision between 3% and 7% for MC simulation and 5-6% for experimental data. Using this method we are able to obtain reliable information about the source depth of Cerenkov luminescence with a simple and flexible procedure.
Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru
2013-11-01
The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (p<0.001), but the distance of that was so small (mean, 0.47 mm) that it did not cause any problem clinically. Although further improvement might be needed, such as screw specification, the closed reduction and internal fixation method has many advantages: short operative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.
Manga Vectorization and Manipulation with Procedural Simple Screentone.
Yao, Chih-Yuan; Hung, Shih-Hsuan; Li, Guo-Wei; Chen, I-Yu; Adhitya, Reza; Lai, Yu-Chi
2017-02-01
Manga are a popular artistic form around the world, and artists use simple line drawing and screentone to create all kinds of interesting productions. Vectorization is helpful to digitally reproduce these elements for proper content and intention delivery on electronic devices. Therefore, this study aims at transforming scanned Manga to a vector representation for interactive manipulation and real-time rendering with arbitrary resolution. Our system first decomposes the patch into rough Manga elements including possible borders and shading regions using adaptive binarization and screentone detector. We classify detected screentone into simple and complex patterns: our system extracts simple screentone properties for refining screentone borders, estimating lighting, compensating missing strokes inside screentone regions, and later resolution independently rendering with our procedural shaders. Our system treats the others as complex screentone areas and vectorizes them with our proposed line tracer which aims at locating boundaries of all shading regions and polishing all shading borders with the curve-based Gaussian refiner. A user can lay down simple scribbles to cluster Manga elements intuitively for the formation of semantic components, and our system vectorizes these components into shading meshes along with embedded Bézier curves as a unified foundation for consistent manipulation including pattern manipulation, deformation, and lighting addition. Our system can real-time and resolution independently render the shading regions with our procedural shaders and drawing borders with the curve-based shader. For Manga manipulation, the proposed vector representation can be not only magnified without artifacts but also deformed easily to generate interesting results.
Electronic test and calibration circuits, a compilation
NASA Technical Reports Server (NTRS)
1972-01-01
A wide variety of simple test calibration circuits are compiled for the engineer and laboratory technician. The majority of circuits were found inexpensive to assemble. Testing electronic devices and components, instrument and system test, calibration and reference circuits, and simple test procedures are presented.
Zimmerman, Carl-Ulrich R; Stiedl, Thomas; Spergser, Joachim; Rosengarten, Renate
2014-09-01
A simple method for preparing agar plates is presented, which allows an efficient transfer of Ureaplasma colonies to nitrocellulose membranes for subsequent immunological detection. This simple and reproducible procedure was used to demonstrate antigenic variation in the phase-variable mba-locus of Ureaplasma parvum serovar 3. Copyright © 2014 Elsevier B.V. All rights reserved.
Energy awareness for supercapacitors using Kalman filter state-of-charge tracking
NASA Astrophysics Data System (ADS)
Nadeau, Andrew; Hassanalieragh, Moeen; Sharma, Gaurav; Soyata, Tolga
2015-11-01
Among energy buffering alternatives, supercapacitors can provide unmatched efficiency and durability. Additionally, the direct relation between a supercapacitor's terminal voltage and stored energy can improve energy awareness. However, a simple capacitive approximation cannot adequately represent the stored energy in a supercapacitor. It is shown that the three branch equivalent circuit model provides more accurate energy awareness. This equivalent circuit uses three capacitances and associated resistances to represent the supercapacitor's internal SOC (state-of-charge). However, the SOC cannot be determined from one observation of the terminal voltage, and must be tracked over time using inexact measurements. We present: 1) a Kalman filtering solution for tracking the SOC; 2) an on-line system identification procedure to efficiently estimate the equivalent circuit's parameters; and 3) experimental validation of both parameter estimation and SOC tracking for 5 F, 10 F, 50 F, and 350 F supercapacitors. Validation is done within the operating range of a solar powered application and the associated power variability due to energy harvesting. The proposed techniques are benchmarked against the simple capacitive model and prior parameter estimation techniques, and provide a 67% reduction in root-mean-square error for predicting usable buffered energy.
Simple Numerical Modelling for Gasdynamic Design of Wave Rotors
NASA Astrophysics Data System (ADS)
Okamoto, Koji; Nagashima, Toshio
The precise estimation of pressure waves generated in the passages is a crucial factor in wave rotor design. However, it is difficult to estimate the pressure wave analytically, e.g. by the method of characteristics, because the mechanism of pressure-wave generation and propagation in the passages is extremely complicated as compared to that in a shock tube. In this study, a simple numerical modelling scheme was developed to facilitate the design procedure. This scheme considers the three dominant factors in the loss mechanism —gradual passage opening, wall friction and leakage— for simulating the pressure waves precisely. The numerical scheme itself is based on the one-dimensional Euler equations with appropriate source terms to reduce the calculation time. The modelling of these factors was verified by comparing the results with those of a two-dimensional numerical simulation, which were previously validated by the experimental data in our previous study. Regarding wave rotor miniaturization, the leakage flow effect, which involves the interaction between adjacent cells, was investigated extensively. A port configuration principle was also examined and analyzed in detail to verify the applicability of the present numerical modelling scheme to the wave rotor design.
Salonen, K; Leisola, M; Eerikäinen, T
2009-01-01
Determination of metabolites from an anaerobic digester with an acid base titration is considered as superior method for many reasons. This paper describes a practical at line compatible multipoint titration method. The titration procedure was improved by speed and data quality. A simple and novel control algorithm for estimating a variable titrant dose was derived for this purpose. This non-linear PI-controller like algorithm does not require any preliminary information from sample. Performance of this controller is superior compared to traditional linear PI-controllers. In addition, simplification for presenting polyprotic acids as a sum of multiple monoprotic acids is introduced along with a mathematical error examination. A method for inclusion of the ionic strength effect with stepwise iteration is shown. The titration model is presented with matrix notations enabling simple computation of all concentration estimates. All methods and algorithms are illustrated in the experimental part. A linear correlation better than 0.999 was obtained for both acetate and phosphate used as model compounds with slopes of 0.98 and 1.00 and average standard deviations of 0.6% and 0.8%, respectively. Furthermore, insensitivity of the presented method for overlapping buffer capacity curves was shown.
Bavili Tabrizi, Ahad; Abdollahi, Ali
2015-10-01
A simple, rapid and sensitive spectrofluorimetric method was developed for the determination of di-syston, ethion and phorate in environmental water samples. The procedure is based on the oxidation of these pesticides with cerium (IV) to produce cerium (III), and its fluorescence was monitored at 368 ± 3 nm after excitation at 257 ± 3 nm. The variables effecting oxidation of each pesticide were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 0.2-15, 0.1-13, 0.1-13 ng mL(-1) for di-syston, ethion and phorate, respectively. The limit of detection and quantification were in the range 0.034-0.096 and 0.112-0.316 ng mL(-1), respectively. Intra- and inter-day assay precisions, expressed as the relative standard deviation (RSD), were lower than 5.2 % and 6.7 %, respectively. Good recoveries in the range 86 %-108 % were obtained for spiked water samples. The proposed method was applied to the determination of studied pesticides in environmental water samples.
Kaban, Leonard B; Cappetta, Alyssa; George, Brian C; Lahey, Edward T; Bohnen, Jordan D; Troulis, Maria J
2017-10-01
There are no universally accepted tools to evaluate operative skills of surgical residents in a timely fashion. The purpose of this study was to determine the feasibility of using a smartphone application, SIMPL (System for Improving and Measuring Procedural Learning), developed by a multi-institutional research collaborative, to achieve a high rate of timely operative evaluations and resident communication and to collect performance data. The authors hypothesized that these goals would be achieved because the process is convenient and efficient. This was a prospective feasibility and engagement study using SIMPL to evaluate residents' operative skills. SIMPL requires the attending surgeon to answer 3 multiple-choice questions: 1) What level of help (Zwisch Scale) was required by the trainee? 2) What was the level of performance? 3) How complex was the case? The evaluator also can dictate a narrative. The sample was composed of 3 faculty members and 3 volunteer senior residents. Predictor variables were the surgeons, trainees, and procedures performed. Outcome variables included number and percentage of procedures performed by faculty-and-resident pairs assessed, time required to complete assessments, time lapsed to submission, percentage of assessments with narratives, and residents' response rates. From March through June 2016, 151 procedures were performed in the operating room by the faculty-and-resident teams. There were 107 assessments submitted (71%). Resident response (self-assessment) to faculty evaluations was 81%. Recorded time to complete assessments (n = 75 of 107) was shorter than 2 minutes. The time lapsed to submission was shorter than 72 hours (100%). Dictations were submitted for 35 evaluations (33%). Data for the type of help, performance, and complexity of cases were collected for each resident. SIMPL facilitates timely intraoperative evaluations of surgical skills, engagement by faculty and residents, and collection of detailed procedural data. Additional prospective trials to assess this tool further are planned. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
QUEST - A Bayesian adaptive psychometric method
NASA Technical Reports Server (NTRS)
Watson, A. B.; Pelli, D. G.
1983-01-01
An adaptive psychometric procedure that places each trial at the current most probable Bayesian estimate of threshold is described. The procedure takes advantage of the common finding that the human psychometric function is invariant in form when expressed as a function of log intensity. The procedure is simple, fast, and efficient, and may be easily implemented on any computer.
ERIC Educational Resources Information Center
Petscher, Yaacov; Schatschneider, Christopher
2011-01-01
Research by Huck and McLean (1975) demonstrated that the covariance-adjusted score is more powerful than the simple difference score, yet recent reviews indicate researchers are equally likely to use either score type in two-wave randomized experimental designs. A Monte Carlo simulation was conducted to examine the conditions under which the…
Control of the collapse distance in atmospheric propagation
NASA Astrophysics Data System (ADS)
Fibich, Gadi; Sivan, Yonatan; Ehrlich, Yosi; Louzon, Einat; Fraenkel, Moshe; Eisenmann, Shmuel; Katzir, Yiftach; Zigler, Arie
2006-06-01
We show experimentally for ultrashort laser pulses propagating in air, that the collapse/filamentation distance of intense laser pulses in the atmosphere can be extended and controlled with a simple double-lens setup. We derive a simple formula for the filamentation distance, and confirm its agreement with the experimental results. We also observe that delaying the onset of filamentation increases the filament length.
Side, Domenico Delle; Nassisi, Vincenzo; Pennetta, Cecilia; Alifano, Pietro; Di Salvo, Marco; Talà, Adelfia; Chechkin, Aleksei; Seno, Flavio
2017-01-01
We present an effective dynamical model for the onset of bacterial bioluminescence, one of the most studied quorum sensing-mediated traits. Our model is built upon simple equations that describe the growth of the bacterial colony, the production and accumulation of autoinducer signal molecules, their sensing within bacterial cells, and the ensuing quorum activation mechanism that triggers bioluminescent emission. The model is directly tested to quantitatively reproduce the experimental distributions of photon emission times, previously measured for bacterial colonies of Vibrio jasicida, a luminescent bacterium belonging to the Harveyi clade, growing in a highly drying environment. A distinctive and novel feature of the proposed model is bioluminescence ‘quenching’ after a given time elapsed from activation. Using an advanced fitting procedure based on the simulated annealing algorithm, we are able to infer from the experimental observations the biochemical parameters used in the model. Such parameters are in good agreement with the literature data. As a further result, we find that, at least in our experimental conditions, light emission in bioluminescent bacteria appears to originate from a subtle balance between colony growth and quorum activation due to autoinducers diffusion, with the two phenomena occurring on the same time scale. This finding is consistent with a negative feedback mechanism previously reported for Vibrio harveyi. PMID:29308273
Side, Domenico Delle; Nassisi, Vincenzo; Pennetta, Cecilia; Alifano, Pietro; Di Salvo, Marco; Talà, Adelfia; Chechkin, Aleksei; Seno, Flavio; Trovato, Antonio
2017-12-01
We present an effective dynamical model for the onset of bacterial bioluminescence, one of the most studied quorum sensing-mediated traits. Our model is built upon simple equations that describe the growth of the bacterial colony, the production and accumulation of autoinducer signal molecules, their sensing within bacterial cells, and the ensuing quorum activation mechanism that triggers bioluminescent emission. The model is directly tested to quantitatively reproduce the experimental distributions of photon emission times, previously measured for bacterial colonies of Vibrio jasicida , a luminescent bacterium belonging to the Harveyi clade, growing in a highly drying environment. A distinctive and novel feature of the proposed model is bioluminescence 'quenching' after a given time elapsed from activation. Using an advanced fitting procedure based on the simulated annealing algorithm, we are able to infer from the experimental observations the biochemical parameters used in the model. Such parameters are in good agreement with the literature data. As a further result, we find that, at least in our experimental conditions, light emission in bioluminescent bacteria appears to originate from a subtle balance between colony growth and quorum activation due to autoinducers diffusion, with the two phenomena occurring on the same time scale. This finding is consistent with a negative feedback mechanism previously reported for Vibrio harveyi .
Permutation tests for goodness-of-fit testing of mathematical models to experimental data.
Fişek, M Hamit; Barlas, Zeynep
2013-03-01
This paper presents statistical procedures for improving the goodness-of-fit testing of theoretical models to data obtained from laboratory experiments. We use an experimental study in the expectation states research tradition which has been carried out in the "standardized experimental situation" associated with the program to illustrate the application of our procedures. We briefly review the expectation states research program and the fundamentals of resampling statistics as we develop our procedures in the resampling context. The first procedure we develop is a modification of the chi-square test which has been the primary statistical tool for assessing goodness of fit in the EST research program, but has problems associated with its use. We discuss these problems and suggest a procedure to overcome them. The second procedure we present, the "Average Absolute Deviation" test, is a new test and is proposed as an alternative to the chi square test, as being simpler and more informative. The third and fourth procedures are permutation versions of Jonckheere's test for ordered alternatives, and Kendall's tau(b), a rank order correlation coefficient. The fifth procedure is a new rank order goodness-of-fit test, which we call the "Deviation from Ideal Ranking" index, which we believe may be more useful than other rank order tests for assessing goodness-of-fit of models to experimental data. The application of these procedures to the sample data is illustrated in detail. We then present another laboratory study from an experimental paradigm different from the expectation states paradigm - the "network exchange" paradigm, and describe how our procedures may be applied to this data set. Copyright © 2012 Elsevier Inc. All rights reserved.
Mechanical Resonance of a Plastic Strip.
ERIC Educational Resources Information Center
Ayers, R. Dean
1981-01-01
Presents an experiment to illustrate mechanical resonance designed for use in lower division laboratories. The apparatus and procedure have been kept simple. The basic experiment yields measurements of amplitude versus driving frequency, but a fairly simple elaboration allows for measurements of phase lag as well. (Author/SK)
Understanding Exponential Growth: As Simple as a Drop in a Bucket.
ERIC Educational Resources Information Center
Goldberg, Fred; Shuman, James
1984-01-01
Provides procedures for a simple laboratory activity on exponential growth and its characteristic doubling time. The equipment needed consists of a large plastic bucket, an eyedropper, a stopwatch, an assortment of containers and graduated cylinders, and a supply of water. (JN)
Simple Experiments on Magnetism and Electricity...from Edison.
ERIC Educational Resources Information Center
Schultz, Robert F.
Background information, lists of materials needed and procedures used are provided for 16 simple experiments on electricity and magnetism. These experiments are organized into sections dealing with: (1) Edison's carbon experiments (building a galvanometer, investigating the variable conductivity of carbon, and examining the carbon transmitter…
Complexity, Training Paradigm Design, and the Contribution of Memory Subsystems to Grammar Learning
Ettlinger, Marc; Wong, Patrick C. M.
2016-01-01
Although there is variability in nonnative grammar learning outcomes, the contributions of training paradigm design and memory subsystems are not well understood. To examine this, we presented learners with an artificial grammar that formed words via simple and complex morphophonological rules. Across three experiments, we manipulated training paradigm design and measured subjects' declarative, procedural, and working memory subsystems. Experiment 1 demonstrated that passive, exposure-based training boosted learning of both simple and complex grammatical rules, relative to no training. Additionally, procedural memory correlated with simple rule learning, whereas declarative memory correlated with complex rule learning. Experiment 2 showed that presenting corrective feedback during the test phase did not improve learning. Experiment 3 revealed that structuring the order of training so that subjects are first exposed to the simple rule and then the complex improved learning. The cumulative findings shed light on the contributions of grammatical complexity, training paradigm design, and domain-general memory subsystems in determining grammar learning success. PMID:27391085
Geary, D C; Frensch, P A; Wiley, J G
1993-06-01
Thirty-six younger adults (10 male, 26 female; ages 18 to 38 years) and 36 older adults (14 male, 22 female; ages 61 to 80 years) completed simple and complex paper-and-pencil subtraction tests and solved a series of simple and complex computer-presented subtraction problems. For the computer task, strategies and solution times were recorded on a trial-by-trial basis. Older Ss used a developmentally more mature mix of problem-solving strategies to solve both simple and complex subtraction problems. Analyses of component scores derived from the solution times suggest that the older Ss are slower at number encoding and number production but faster at executing the borrow procedure. In contrast, groups did not appear to differ in the speed of subtraction fact retrieval. Results from a computational simulation are consistent with the interpretation that older adults' advantage for strategy choices and for the speed of executing the borrow procedure might result from more practice solving subtraction problems.
Capacitive sensor for engine oil deterioration measurement
NASA Astrophysics Data System (ADS)
Shinde, Harish; Bewoor, Anand
2018-04-01
A simple system or mechanism for engine Oil (lubricating oil) deterioration monitoring is a need. As engine oil is an important element in I C engines and it is exposed to various strains depending on the operating conditions. If it becomes contaminated with dirt and metal particles, it can become too thick or thin and loses its protective properties, leads to unwanted friction. In turn, to avoid an engine failure, the oil must be changed before it loses its protective properties, which may be harmful to engine which deteriorates vehicle performance. At the same time, changing the lubricant too early, cause inefficient use of already depleting resources, also unwanted impact on the environment and economic reasons. Hence, it will be always helpful to know the quality of the oil under use. With this objective, the research work had been undertaken to develop a simple capacitance sensor for quantification of the quality of oil under use. One of the investigated parameter to quantify oil degradation is Viscosity (as per standard testing procedure: DIN 51562-1). In this research work, an alternative method proposed which analyzing change in capacitance of oil, to quantify the quality of oil underuse and compared to a conventional standard method. The experimental results reported in this paper shows trend for the same. Engine oil of grade SAE 15W40 used for light-duty vehicle, vans and passenger cars is used for experimentation. Suggested method can form a base for further research to develop a cost-effective method for indicating the time to change in engine oil quality have been presented.
Justifying scale type for a latent variable: Formative or reflective?
NASA Astrophysics Data System (ADS)
Liu, Hao; Bahron, Arsiah; Bagul, Awangku Hassanal Bahar Pengiran
2015-12-01
The study attempted to explore the possibilities to create a procedure at the experimental level to double confirm whether manifest variables scale type is formative or reflective. Now, the criteria of making such a decision are heavily depended on researchers' judgment at the conceptual and operational level. The study created an experimental procedure that seems could double confirm the decisions from the conceptual and operational level judgments. The experimental procedure includes the following tests, Variance Inflation Factor (VIF), Tolerance (TOL), Ridge Regression, Cronbach's alpha, Dillon-Goldstein's rho, and first and second eigenvalue. The procedure considers manifest variables' both multicollinearity and consistency. As the result, the procedure received the same judgment with the carefully established decision making at the concept and operational level.
DOT National Transportation Integrated Search
2006-01-01
A previous study developed a procedure for microscopic simulation model calibration and validation and evaluated the procedure via two relatively simple case studies using three microscopic simulation models. Results showed that default parameters we...
Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.
Smith, R F; Mather, H M; Ellard, G A
1998-02-01
The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.
Robotic general surgery experience: a gradual progress from simple to more complex procedures.
Al-Naami, M; Anjum, M N; Aldohayan, A; Al-Khayal, K; Alkharji, H
2013-12-01
Robotic surgery was introduced at our institution in 2003, and we used a progressive approach advancing from simple to more complex procedures. A retrospective chart review. Cases included totalled 129. Set-up and operative times have improved over time and with experience. Conversion rates to standard laparoscopic or open techniques were 4.7% and 1.6%, respectively. Intraoperative complications (6.2%), blood loss and hospital stay were directly proportional to complexity. There were no mortalities and the postoperative complication rate (13.2%) was within accepted norms. Our findings suggest that robot technology is presently most useful in cases tailored toward its advantages, i.e. those confined to a single space, those that require performance of complex tasks, and re-do procedures. Copyright © 2013 John Wiley & Sons, Ltd.
Herbst, M; Lehmhus, H; Oldenburg, B; Orlowski, C; Ohgke, H
1983-04-01
A simple experimental set for the production and investigation of bacterially contaminated solid-state aerosols with constant concentration is described. The experimental set consists mainly of a fluidized bed-particle generator within a modified chamber for formaldehyde desinfection. The special conditions for the production of a defined concentration of particles and microorganisms are to be found out empirically. In a first application aerosol-sizing of an Andersen sampler is investigated. The findings of Andersen (1) are confirmed with respect to our experimental conditions.
Experimental study of pancreaticojejunostomy completed using anastomotic chains
NASA Astrophysics Data System (ADS)
Pan, Wei-Dong; Xu, Rui-Yun; Li, Nan; Fang, He-Ping; Pan, Cu-Zhi; Tang, Zhao-Feng
2010-07-01
The most difficult, time-consuming, and complication-prone step in pancreaticoduodenectomy is the pancreaticojejunostomy step. The largest disadvantage of this kind of anastomosis is the high incidence of postoperative anastomotic leakage. Once pancreatic leakage occurs, the patient death rate can be very high. The aim of this study was to design a pancreaticojejunostomy procedure using anastomotic chains, which results in the cut end of the jejunum being attached to the pancreatic stump without suturing, and to evaluate the safety and efficacy of this procedure in domestic pigs. The pancreaticojejunal anastomotic chains had the following structures: the chains consisted of two braceletlike chains made of titanium, named chain A and chain B. The function of chain A was to attach the free jejunal end onto the pancreatic stump, whereas the function of chain B was to tighten the contact between the jejunal wall and the surface of the pancreatic stump to eliminate gaps between the two structures and ensure tightness that is sufficient to guarantee that there is no leakage of jejunal fluid or pancreatic juice. The following procedure was used to assess the safety and efficacy of the procedure: pancreaticojejunostomies were performed on ten domestic pigs using anastomotic chains. The time required to complete the pancreaticojejunal anastomoses, the pressure tolerance of the pancreaticojejunal anastomoses, the pig death rate, and the histopathological examinations of the pancreaticojejunostomy tissues were recorded. The average time required to complete the pancreaticojejunal anastomosis procedure was 13±2 min. The observed tolerance pressure of the pancreaticojejunal anastomoses was more than 90 mm H2O. All ten domestic pigs that underwent operations were still alive four weeks after the operations. Pathological examinations showed that the anastomotic surfaces were completely healed, and the pancreatic cutting surfaces were primarily epithelialized. In conclusion, the use of anastomotic chains in pancreaticojejunostomy procedures results in a decrease in or elimination of pancreatic leakage. In addition, the procedure is simple to perform, is not time-intensive, and appears to be safe in a pig model.
Qamar, Wajhul
2015-01-01
Bronchoalveolar lavage fluid (BALF) is an important tool in experimental toxicology and pharmacology. A number of researchers have utilized BAL in studies involving rodents. However, the detailed procedure of performing BAL in rodents has rarely been reported. In the present article, in situ BAL in rats has been described with technical points that ensure the quality and validity of BALF samples. BAL was performed in rats of Wistar strain. Flow cytometry and microscopy were utilized to analyze the BAL cells. The collected volume of BALF was 84.32 ± 2.7% of instilled volume. Alveolar macrophages were found to be prevalent in normal lungs when analyzed under microscope and by flow cytometry. The main problem that one may face is the accidental contamination of BALF samples with blood of the animal itself. Presence of blood in BALF certainly adds a significant number of cells and other biochemical variables. No blood contamination was detected in BALF. Here, a simple procedure for BAL and collection of alveolar cells (macrophages in the present study) is explained with an emphasis on technical steps and precautions, which ensures the quality of the BALF samples. Data exhibit that there is no blood contamination in the BALF and provide evidence that the technical points considered in the procedure here are successful in maintaining the quality and validity of BALF samples.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.
2017-03-01
Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.
Procedures for cryogenic X-ray ptychographic imaging of biological samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yusuf, M.; Zhang, F.; Chen, B.
Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This paper describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to Health Care Technology § 405.211 Procedures for Medicare contractors in making coverage decisions... 42 Public Health 2 2010-10-01 2010-10-01 false Procedures for Medicare contractors in making coverage decisions for a non-experimental/investigational (Category B) device. 405.211 Section 405.211...
Procedures for cryogenic X-ray ptychographic imaging of biological samples
Yusuf, M.; Zhang, F.; Chen, B.; ...
2017-01-12
Biological sample-preparation procedures have been developed for imaging human chromosomes under cryogenic conditions. A new experimental setup, developed for imaging frozen samples using beamline I13 at Diamond Light Source, is described. This paper describes the equipment and experimental procedures as well as the authors' first ptychographic reconstructions using X-rays.
ERIC Educational Resources Information Center
Sobrero, Patricio; Valverde, Claudio
2013-01-01
A simple and cheap laboratory class is proposed to illustrate the lethal effect of UV radiation on bacteria and the operation of different DNA repair mechanisms. The class is divided into two sessions, an initial 3-hour experimental session and a second 2-hour analytical session. The experimental session involves two separate experiments: one…
A simple model of proton damage in GaAs solar cells
NASA Technical Reports Server (NTRS)
Wilson, J. W.; Walker, G. H.; Outlaw, R. A.
1982-01-01
A simple proton damage model for GaAs solar cells is derived and compared to experimental values of change in short circuit currents. The recombination cross section associated with the defects was determined from the experimental comparison to be approximately 1.2 x 10 to the -13th power sq cm in fair agreement with values determined from the deep level transient spectroscopy technique.
Integrated data analysis for genome-wide research.
Steinfath, Matthias; Repsilber, Dirk; Scholz, Matthias; Walther, Dirk; Selbig, Joachim
2007-01-01
Integrated data analysis is introduced as the intermediate level of a systems biology approach to analyse different 'omics' datasets, i.e., genome-wide measurements of transcripts, protein levels or protein-protein interactions, and metabolite levels aiming at generating a coherent understanding of biological function. In this chapter we focus on different methods of correlation analyses ranging from simple pairwise correlation to kernel canonical correlation which were recently applied in molecular biology. Several examples are presented to illustrate their application. The input data for this analysis frequently originate from different experimental platforms. Therefore, preprocessing steps such as data normalisation and missing value estimation are inherent to this approach. The corresponding procedures, potential pitfalls and biases, and available software solutions are reviewed. The multiplicity of observations obtained in omics-profiling experiments necessitates the application of multiple testing correction techniques.
[Study on the kinetic fluorimetric determination of tannins in tea].
Feng, Su-ling; Tang, Jun-ming; Fan, Jing
2003-04-01
A simple and highly sensitive kinetic fluorimetric method is proposed for the determination of trace tannins, based on the activation of tannins on the oxidation of pyronine Y by hydrogen peroxide catalyzed by Cu(II) ion. The effects of some experimental conditions were investigated and discussed in detail. The fixed reaction time procedure was used to determine the fluorescence intensity of the system. The calibration curve of tannin was linear in the range of 0.06-0.96 mg.L-1, and the detection limit for tannin was 0.032 mg.L-1. The relative standard deviation for the measurement of 0.32 mg.L-1 tannin (n = 11) was 2.3%. The proposed method has been successfully applied to the determination of tannins in tea. The results obtained were compared with those provided by the Folin-Ciocalteu method.
NASA Technical Reports Server (NTRS)
Gupta, S. K.; Tiwari, S. N.
1976-01-01
A simple procedure and computer program were developed for retrieving the surface temperature from the measurement of upwelling infrared radiance in a single spectral region in the atmosphere. The program evaluates the total upwelling radiance at any altitude in the region of the CO fundamental band (2070-2220 1/cm) for several values of surface temperature. Actual surface temperature is inferred by interpolation of the measured upwelling radiance between the computed values of radiance for the same altitude. Sensitivity calculations were made to determine the effect of uncertainty in various surface, atmospheric and experimental parameters on the inferred value of surface temperature. It is found that the uncertainties in water vapor concentration and surface emittance are the most important factors affecting the accuracy of the inferred value of surface temperature.
Adaptive Discrete Hypergraph Matching.
Yan, Junchi; Li, Changsheng; Li, Yin; Cao, Guitao
2018-02-01
This paper addresses the problem of hypergraph matching using higher-order affinity information. We propose a solver that iteratively updates the solution in the discrete domain by linear assignment approximation. The proposed method is guaranteed to converge to a stationary discrete solution and avoids the annealing procedure and ad-hoc post binarization step that are required in several previous methods. Specifically, we start with a simple iterative discrete gradient assignment solver. This solver can be trapped in an -circle sequence under moderate conditions, where is the order of the graph matching problem. We then devise an adaptive relaxation mechanism to jump out this degenerating case and show that the resulting new path will converge to a fixed solution in the discrete domain. The proposed method is tested on both synthetic and real-world benchmarks. The experimental results corroborate the efficacy of our method.
Effective doping of low energy ions into superfluid helium droplets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jie; Chen, Lei; Freund, William M.
2015-08-21
We report a facile method of doping cations from an electrospray ionization (ESI) source into superfluid helium droplets. By decelerating and stopping the ion pulse of reserpine and substance P from an ESI source in the path of the droplet beam, about 10{sup 4} ion-doped droplets (one ion per droplet) can be recorded, corresponding to a pickup efficiency of nearly 1 out of 1000 ions. We attribute the success of this simple approach to the long residence time of the cations in the droplet beam. The resulting size of the doped droplets, on the order of 10{sup 5}/droplet, is measuredmore » using deflection and retardation methods. Our method does not require an ion trap in the doping region, which significantly simplifies the experimental setup and procedure for future spectroscopic and diffraction studies.« less
Palladium nanoparticles formed on titanium silicate ETS-10.
Lin, Christopher C H; Danaie, Mohsen; Mitlin, David; Kuznicki, Steven M
2011-03-01
We report that surface templated and supported palladium nanoparticles self assemble on ETS-10 type molecular sieve surfaces by simple exchange and activation procedures in the absence of a reductant. This procedure is similar to the one previously reported for silver nanoparticle self assembly on ETS-10. We observed a bimodal distribution with particle sizes ranging from 2-5 and 15-30 nm. This simple, economical method generates high concentrations (approximately 12 wt% of total composite) of uniform, metallic palladium nanoparticles that are multiply twinned and thermally stable making them potentially unique for advanced catalytic and electronic applications.
İşlekdemir, Burcu; Kaya, Nurten
2016-01-01
Patients generally prefer to have their family present during medical or nursing interventions. Family presence is assumed to reduce anxiety, especially during painful interventions. This study employed a randomized controlled experimental design to determine the effects of family presence on pain and anxiety during invasive nursing procedures. The study population consisted of patients hospitalized in the observation unit of the internal medicine section in the emergency department of a university hospital. The sample comprised 138 patients assigned into the experimental and control groups by drawing lots. The invasive nursing procedure was carried out in the presence of family members, for members of the experimental group, and without family members, for members of the control group. Thus, the effects of family presence on pain and anxiety during the administration of an invasive nursing procedure to patients were analyzed. The results showed that members of the experimental and control groups did not differ with respect to the pain and state anxiety scores during the intervention. Family presence does not influence the participants' pain and anxiety during an invasive nursing procedure. Thus, the decision regarding family presence during such procedures should be based on patient preference. Copyright © 2015 Elsevier Ltd. All rights reserved.
Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.
Sparding, Nadja; Slotved, Hans-Christian; Nicolaisen, Gert M; Giese, Steen B; Elmlund, Jón; Steenhard, Nina R
2014-01-01
After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin) with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments) for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.
Mortensen, Kim I; Tassone, Chiara; Ehrlich, Nicky; Andresen, Thomas L; Flyvbjerg, Henrik
2018-05-09
Nanosize lipid vesicles are used extensively at the interface between nanotechnology and biology, e.g., as containers for chemical reactions at minute concentrations and vehicles for targeted delivery of pharmaceuticals. Typically, vesicle samples are heterogeneous as regards vesicle size and structural properties. Consequently, vesicles must be characterized individually to ensure correct interpretation of experimental results. Here we do that using dual-color fluorescence labeling of vesicles-of their lipid bilayers and lumens, separately. A vesicle then images as two spots, one in each color channel. A simple image analysis determines the total intensity and width of each spot. These four data all depend on the vesicle radius in a simple manner for vesicles that are spherical, unilamellar, and optimal encapsulators of molecular cargo. This permits identification of such ideal vesicles. They in turn enable calibration of the dual-color fluorescence microscopy images they appear in. Since this calibration is not a separate experiment but an analysis of images of vesicles to be characterized, it eliminates the potential source of error that a separate calibration experiment would have been. Nonideal vesicles in the same images were characterized by how their four data violate the calibrated relationship established for ideal vesicles. In this way, our method yields size, shape, lamellarity, and encapsulation efficiency of each imaged vesicle. Applying this procedure to extruded samples of vesicles, we found that, contrary to common assumptions, only a fraction of vesicles are ideal.
Relaxation and Distraction in Experimental Desensitization.
ERIC Educational Resources Information Center
Weir, R. O.; Marshall, W. L.
1980-01-01
Compared experimental desensitization with a procedure that replaced relaxation with a distraction task and with an approach that combined both relaxation and distraction. Desensitization generally was more effective than the other two procedures. (Author)
Solving Simple Kinetics without Integrals
ERIC Educational Resources Information Center
de la Pen~a, Lisandro Herna´ndez
2016-01-01
The solution of simple kinetic equations is analyzed without referencing any topic from differential equations or integral calculus. Guided by the physical meaning of the rate equation, a systematic procedure is used to generate an approximate solution that converges uniformly to the exact solution in the case of zero, first, and second order…
ERIC Educational Resources Information Center
Britton, L. N.; And Others
1988-01-01
Considers the applicability of the simple emersion/weight-gain method for predicting diffusion coefficients, solubilities, and permeation rates of chemicals in polymers that do not undergo physical and chemical deterioration. Presents the theoretical background, procedures and typical results related to this activity. (CW)
Numerous extraction methods have been developed and used in the quantitation of both photopigments and mycosporine amino acids (MAAs) found in Symbiodinium sp. and zooanthellate metazoans. We have development of a simple, mild extraction procedure using methanol, which when coupl...
General theory of remote gaze estimation using the pupil center and corneal reflections.
Guestrin, Elias Daniel; Eizenman, Moshe
2006-06-01
This paper presents a general theory for the remote estimation of the point-of-gaze (POG) from the coordinates of the centers of the pupil and corneal reflections. Corneal reflections are produced by light sources that illuminate the eye and the centers of the pupil and corneal reflections are estimated in video images from one or more cameras. The general theory covers the full range of possible system configurations. Using one camera and one light source, the POG can be estimated only if the head is completely stationary. Using one camera and multiple light sources, the POG can be estimated with free head movements, following the completion of a multiple-point calibration procedure. When multiple cameras and multiple light sources are used, the POG can be estimated following a simple one-point calibration procedure. Experimental and simulation results suggest that the main sources of gaze estimation errors are the discrepancy between the shape of real corneas and the spherical corneal shape assumed in the general theory, and the noise in the estimation of the centers of the pupil and corneal reflections. A detailed example of a system that uses the general theory to estimate the POG on a computer screen is presented.
An interval model updating strategy using interval response surface models
NASA Astrophysics Data System (ADS)
Fang, Sheng-En; Zhang, Qiu-Hu; Ren, Wei-Xin
2015-08-01
Stochastic model updating provides an effective way of handling uncertainties existing in real-world structures. In general, probabilistic theories, fuzzy mathematics or interval analyses are involved in the solution of inverse problems. However in practice, probability distributions or membership functions of structural parameters are often unavailable due to insufficient information of a structure. At this moment an interval model updating procedure shows its superiority in the aspect of problem simplification since only the upper and lower bounds of parameters and responses are sought. To this end, this study develops a new concept of interval response surface models for the purpose of efficiently implementing the interval model updating procedure. The frequent interval overestimation due to the use of interval arithmetic can be maximally avoided leading to accurate estimation of parameter intervals. Meanwhile, the establishment of an interval inverse problem is highly simplified, accompanied by a saving of computational costs. By this means a relatively simple and cost-efficient interval updating process can be achieved. Lastly, the feasibility and reliability of the developed method have been verified against a numerical mass-spring system and also against a set of experimentally tested steel plates.
Caciagli, P; Verderio, A
2003-06-30
Several aspects of enzyme-linked immunosorbent assay (ELISA) procedures and data analysis have been examined in an attempt to find a rapid and reliable method for discriminating between 'positive' and 'negative' results when testing a large number of samples. A layout of ELISA plates was designed to reduce uncontrolled variation and to optimize the number of negative and positive controls. A transformation using the fourth root (A(1/4)) of the optical density readings corrected for the blank (A) stabilized the variance of most ELISA data examined. Transformed A values were used to calculate the true limits, at a set protection level, for false positive (C) and false negative (D). Methods are discussed to reduce the number of undifferentiated samples, i.e. the samples with response falling between C and D. The whole procedure was set up for use with an electronic spreadsheet. With the addition of few instructions of the type 'if em leader then em leader else' in the spreadsheet, the ELISA results were obtained in the simple trichotomous form 'negative/undefined/positive'. This allowed rapid analysis of more than 1100 maize samples testing for the presence of seven aphid-borne viruses-in fact almost 8000 ELISA samples.
An automated device for appetitive conditioning in zebrafish (Danio rerio).
Manabe, Kazuchika; Dooling, R J; Takaku, Shinichi
2013-12-01
An automated device and a procedure for the operant conditioning individual zebrafish were developed. The key feature of this procedure was the construction of a simple, inexpensive feeder that can deliver extremely small amounts of food, thus preventing rapid satiation. This allows the experimenter to run multiple trails in a single test session and multiple sessions in one day. In addition, small response keys made from acryl rods and fiber sensors were developed that were sufficiently sensitive to detect fish contact. To illustrate the efficiency and utility of the device for traditional learning paradigms, we trained zebrafish in a fixed ratio schedule where subjects were reinforced with food after 10 responses. Zebrafish reliably responded on the response key for sessions that lasted as long 80-reinforcements. They also showed the traditional "break and run" response pattern that has been found in many species. These results show that this system will be valuable for behavioral studies with zebrafish, especially for experiments that need many repeated trials using food reinforcer in a session. The present system can be used for sensory and learning investigations, as well applications in behavioral pharmacology, behavioral genetics, and toxicology where the zebrafish is becoming the vertebrate model of choice.
A novel procedure for the identification of chaos in complex biological systems
NASA Astrophysics Data System (ADS)
Bazeia, D.; Pereira, M. B. P. N.; Brito, A. V.; Oliveira, B. F. De; Ramos, J. G. G. S.
2017-03-01
We demonstrate the presence of chaos in stochastic simulations that are widely used to study biodiversity in nature. The investigation deals with a set of three distinct species that evolve according to the standard rules of mobility, reproduction and predation, with predation following the cyclic rules of the popular rock, paper and scissors game. The study uncovers the possibility to distinguish between time evolutions that start from slightly different initial states, guided by the Hamming distance which heuristically unveils the chaotic behavior. The finding opens up a quantitative approach that relates the correlation length to the average density of maxima of a typical species, and an ensemble of stochastic simulations is implemented to support the procedure. The main result of the work shows how a single and simple experimental realization that counts the density of maxima associated with the chaotic evolution of the species serves to infer its correlation length. We use the result to investigate others distinct complex systems, one dealing with a set of differential equations that can be used to model a diversity of natural and artificial chaotic systems, and another one, focusing on the ocean water level.
Giordano, Anna; Barresi, Antonello A; Fissore, Davide
2011-01-01
The aim of this article is to show a procedure to build the design space for the primary drying of a pharmaceuticals lyophilization process. Mathematical simulation of the process is used to identify the operating conditions that allow preserving product quality and meeting operating constraints posed by the equipment. In fact, product temperature has to be maintained below a limit value throughout the operation, and the sublimation flux has to be lower than the maximum value allowed by the capacity of the condenser, besides avoiding choking flow in the duct connecting the drying chamber to the condenser. Few experimental runs are required to get the values of the parameters of the model: the dynamic parameters estimation algorithm, an advanced tool based on the pressure rise test, is used to this purpose. A simple procedure is proposed to take into account parameters uncertainty and, thus, it is possible to find the recipes that allow fulfilling the process constraints within the required uncertainty range. The same approach can be effective to take into account the heterogeneity of the batch when designing the freeze-drying recipe. Copyright © 2010 Wiley-Liss, Inc. and the American Pharmacists Association
NASA Astrophysics Data System (ADS)
Bergese, P.; Bontempi, E.; Depero, L. E.
2006-10-01
X-ray reflectivity (XRR) is a non-destructive, accurate and fast technique for evaluating film density. Indeed, sample-goniometer alignment is a critical experimental factor and the overriding error source in XRR density determination. With commercial single-wavelength X-ray reflectometers, alignment is difficult to control and strongly depends on the operator. In the present work, the contribution of misalignment on density evaluation error is discussed, and a novel procedure (named XRR-density evaluation or XRR-DE method) to minimize the problem will be presented. The method allows to overcome the alignment step through the extrapolation of the correct density value from appropriate non-specular XRR data sets. This procedure is operator independent and suitable for commercial single-wavelength X-ray reflectometers. To test the XRR-DE method, single crystals of TiO 2 and SrTiO 3 were used. In both cases the determined densities differed from the nominal ones less than 5.5%. Thus, the XRR-DE method can be successfully applied to evaluate the density of thin films for which only optical reflectivity is today used. The advantage is that this method can be considered thickness independent.
Modeling procedures for handling qualities evaluation of flexible aircraft
NASA Technical Reports Server (NTRS)
Govindaraj, K. S.; Eulrich, B. J.; Chalk, C. R.
1981-01-01
This paper presents simplified modeling procedures to evaluate the impact of flexible modes and the unsteady aerodynamic effects on the handling qualities of Supersonic Cruise Aircraft (SCR). The modeling procedures involve obtaining reduced order transfer function models of SCR vehicles, including the important flexible mode responses and unsteady aerodynamic effects, and conversion of the transfer function models to time domain equations for use in simulations. The use of the modeling procedures is illustrated by a simple example.
Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F
2014-06-01
We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Exemption for investigational use and procedure for obtaining authorization to market edible products from experimental animals. 170.17 Section 170.17 Food and... procedure for obtaining authorization to market edible products from experimental animals. A food additive...
Reversed-phase liquid chromatography column testing: robustness study of the test.
Le Mapihan, K; Vial, J; Jardy, A
2004-12-24
Choosing the right RPLC column for an actual separation among the more than 600 commercially available ones still represents a real challenge for the analyst particularly when basic solutes are involved. Many tests dedicated to the characterization and the classification of stationary phases have been proposed in the literature and some of them highlighted the need of a better understanding of retention properties to lead to a rational choice of columns. However, unlike classical chromatographic methods, the problem of their robustness evaluation has often been left unaddressed. In the present study, we present a robustness study that was applied to the chromatographic testing procedure we had developed and optimized previously. A design of experiment (DoE) approach was implemented. Four factors, previously identified as potentially influent, were selected and subjected to small controlled variations: solvent fraction, temperature, pH and buffer concentration. As our model comprised quadratic terms instead of a simple linear model, we chose a D-optimal design in order to minimize the experiment number. As a previous batch-to-batch study [K. Le Mapihan, Caractérisation et classification des phases stationnaires utilisées pour l'analyse CPL de produits pharmaceutiques, Ph.D. Thesis, Pierre and Marie Curie University, 2004] had shown a low variability on the selected stationary phase, it was then possible to split the design into two parts, according to the solvent nature, each using one column. Actually, our testing procedure involving assays both with methanol and with acetonitrile as organic modifier, such an approach enabled to avoid a possible bias due to the column ageing considering the number of experiments required (16 + 6 center points). Experimental results were computed thanks to a Partial Least Squares regression procedure, more adapted than the classical regression to handle factors and responses not completely independent. The results showed the behavior of the solutes in relation to their physico-chemical properties and the relevance of the second term degree of our model. Finally, the robust domain of the test has been fairly identified, so that any potential user precisely knows to which extend each experimental parameter must be controlled when our testing procedure is to be implemented.
Influence of vapor deposition on structural and charge transport properties of ethylbenzene films
Antony, Lucas W.; Jackson, Nicholas E.; Lyubimov, Ivan; ...
2017-04-14
Organic glass films formed by physical vapor deposition exhibit enhanced stability relative to those formed by conventional liquid cooling and aging techniques. Recently, experimental and computational evidence has emerged indicating that the average molecular orientation can be tuned by controlling the substrate temperature at which these “stable glasses” are grown. In this work, we present a comprehensive all-atom simulation study of ethylbenzene, a canonical stable-glass former, using a computational film formation procedure that closely mimics the vapor deposition process. Atomistic studies of experimentally formed vapor-deposited glasses have not been performed before, and this study therefore begins by verifying that themore » model and method utilized here reproduces key structural features observed experimentally. Having established agreement between several simulated and experimental macroscopic observables, simulations are used to examine the substrate temperature dependence of molecular orientation. The results indicate that ethylbenzene glasses are anisotropic, depending upon substrate temperature, and that this dependence can be understood from the orientation present at the surface of the equilibrium liquid. By treating ethylbenzene as a simple model for molecular semiconducting materials, a quantum-chemical analysis is then used to show that the vapor-deposited glasses exhibit decreased energetic disorder and increased magnitude of the mean-squared transfer integral relative to isotropic, liquid-cooled films, an effect that is attributed to the anisotropic ordering of the molecular film. Finally, these results suggest a novel structure–function simulation strategy capable of tuning the electronic properties of organic semiconducting glasses prior to experimental deposition, which could have considerable potential for organic electronic materials design.« less
Influence of vapor deposition on structural and charge transport properties of ethylbenzene films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antony, Lucas W.; Jackson, Nicholas E.; Lyubimov, Ivan
Organic glass films formed by physical vapor deposition exhibit enhanced stability relative to those formed by conventional liquid cooling and aging techniques. Recently, experimental and computational evidence has emerged indicating that the average molecular orientation can be tuned by controlling the substrate temperature at which these “stable glasses” are grown. In this work, we present a comprehensive all-atom simulation study of ethylbenzene, a canonical stable-glass former, using a computational film formation procedure that closely mimics the vapor deposition process. Atomistic studies of experimentally formed vapor-deposited glasses have not been performed before, and this study therefore begins by verifying that themore » model and method utilized here reproduces key structural features observed experimentally. Having established agreement between several simulated and experimental macroscopic observables, simulations are used to examine the substrate temperature dependence of molecular orientation. The results indicate that ethylbenzene glasses are anisotropic, depending upon substrate temperature, and that this dependence can be understood from the orientation present at the surface of the equilibrium liquid. By treating ethylbenzene as a simple model for molecular semiconducting materials, a quantum-chemical analysis is then used to show that the vapor-deposited glasses exhibit decreased energetic disorder and increased magnitude of the mean-squared transfer integral relative to isotropic, liquid-cooled films, an effect that is attributed to the anisotropic ordering of the molecular film. Finally, these results suggest a novel structure–function simulation strategy capable of tuning the electronic properties of organic semiconducting glasses prior to experimental deposition, which could have considerable potential for organic electronic materials design.« less
Influence of Vapor Deposition on Structural and Charge Transport Properties of Ethylbenzene Films
2017-01-01
Organic glass films formed by physical vapor deposition exhibit enhanced stability relative to those formed by conventional liquid cooling and aging techniques. Recently, experimental and computational evidence has emerged indicating that the average molecular orientation can be tuned by controlling the substrate temperature at which these “stable glasses” are grown. In this work, we present a comprehensive all-atom simulation study of ethylbenzene, a canonical stable-glass former, using a computational film formation procedure that closely mimics the vapor deposition process. Atomistic studies of experimentally formed vapor-deposited glasses have not been performed before, and this study therefore begins by verifying that the model and method utilized here reproduces key structural features observed experimentally. Having established agreement between several simulated and experimental macroscopic observables, simulations are used to examine the substrate temperature dependence of molecular orientation. The results indicate that ethylbenzene glasses are anisotropic, depending upon substrate temperature, and that this dependence can be understood from the orientation present at the surface of the equilibrium liquid. By treating ethylbenzene as a simple model for molecular semiconducting materials, a quantum-chemical analysis is then used to show that the vapor-deposited glasses exhibit decreased energetic disorder and increased magnitude of the mean-squared transfer integral relative to isotropic, liquid-cooled films, an effect that is attributed to the anisotropic ordering of the molecular film. These results suggest a novel structure–function simulation strategy capable of tuning the electronic properties of organic semiconducting glasses prior to experimental deposition, which could have considerable potential for organic electronic materials design. PMID:28573203
Karimi, Shima; Talebpour, Zahra; Adib, Noushin
2016-06-14
A poly acrylate-ethylene glycol (PA-EG) thin film is introduced for the first time as a novel polar sorbent for sorptive extraction method coupled directly to solid-state spectrofluorimetry without the necessity of a desorption step. The structure, polarity, fluorescence property and extraction performance of the developed thin film were investigated systematically. Carvedilol was used as the model analyte to evaluate the proposed method. The entire procedure involved one-step extraction of carvedilol from plasma using PA-EG thin film sorptive phase without protein precipitation. Extraction variables were studied in order to establish the best experimental conditions. Optimum extraction conditions were the followings: stirring speed of 1000 rpm, pH of 6.8, extraction temperature of 60 °C, and extraction time of 60 min. Under optimal conditions, extraction of carvedilol was carried out in spiked human plasma; and the linear range of calibration curve was 15-300 ng mL(-1) with regression coefficient of 0.998. Limit of detection (LOD) for the method was 4.5 ng mL(-1). The intra- and inter-day accuracy and precision of the proposed method were evaluated in plasma sample spiked with three concentration levels of carvedilol; yielding a recovery of 91-112% and relative standard deviation of less than 8%, respectively. The established procedure was successfully applied for quantification of carvedilol in plasma sample of a volunteer patient. The developed PA-EG thin film sorptive phase followed by solid-state spectrofluorimetric method provides a simple, rapid and sensitive approach for the analysis of carvedilol in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Task as a Heuristic for Understanding Student Learning and Motivation.
ERIC Educational Resources Information Center
Blumenfeld, Phyllis C.; And Others
1987-01-01
Describes the cognitive characteristics and procedural "forms" associated with common school learning tasks. Illustrates how variations in these can affect student motivation and learning. Concludes that simple task content and unvaried procedures tend to result in limited thinkers and alienated workers. (JDH)
DEVELOPMENT OF A PROTOCOL FOR TESTING EFFECTS OF TOXIC SUBSTANCES ON PLANTS
This study was designed to devise a rapid, simple, reproducible bioassay procedure to determine effects of so-called 'toxic substances in the environment' on vegetation and provide a standardized procedure for evaluation and comparison of effects of diverse compounds. Eight diffe...
The Effect of Massage on Anticipatory Anxiety and Procedural Pain in Patients with Burn Injury
Najafi Ghezeljeh, Tahereh; Mohades Ardebili, Fatimah; Rafii, Forough; Manafi, Farzad
2017-01-01
BACKGROUND Pain related to burn injuries is one of the most troublesome pain intensity. This study aimed to investigate the effect of massage on anticipatory anxiety, procedural pain intensity, vital signs and relaxation level of patients with burn injury. METHODS In this quasi-experimental study, through convenience sampling, 60 hospitalized adult burn patients were selected from a specialized burn and reconstructive hospital. Subjects were assigned to massage and control groups through simple randomization. Massage was offered by using non aromatic oil about 10-15 minutes before wound care on intact part of the body once a day for 20 minutes on patients’ bedside for 3 consecutive days. In the 3 days, the control group did not received any massage and were asked to stay at bed. Demographic and clinical characteristics and vital signs, Visual Analogue Scale and the Persian version of Burn Specific Pain Anxiety Scale were used to determine baseline and procedural pain, anxiety and relaxation levels and anticipatory anxiety. RESULTS No significant difference was noted between mean score of pain intensity, anxiety and relaxation level, and vital signs in massage and control groups after intervention following wound care. In massage and control groups, there was no significant differences between mean scores of anticipatory anxiety before and after intervention. There was no significant difference between the mean scores of anticipatory anxiety in massage and control groups after intervention prior wound care. CONCLUSION Massage was shown not to have any effect on anticipatory anxiety and procedural pain. PMID:28289612
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egestad, B.; Curstedt, T.; Sjoevall, J.
1982-01-01
Procedures for enrichment of non-volatile chlorinated aromatic pollutants from fat, water and milk are described. /sup 14/C-DDT was used as a model compound in recovery experiments. A several thousand-fold enrichment of DDT added to butter was achieved by two consecutive straight-phase chromatographies on Lipidex 5000. Trace amounts of DDT in liter volumes of water could be quantitatively extracted by rapid filtration through 2 ml beds of Lipidex 1000. A batch extraction procedure permitted enrichment of DDT from milk after addition of n-pentylamine, methanol and water. DDT could then be eluted from the gel with retention of more than 90% ofmore » the lipids. A reversed-phase system with Lipidex 5000 could be used for separation of TCDD from DDT and PCBs. The liquid-gel chromatographic procedures are simple and suitable for clean-up of samples prior to application of high-resolution methods. 5 tables.« less
A design procedure for the phase-controlled parallel-loaded resonant inverter
NASA Technical Reports Server (NTRS)
King, Roger J.
1989-01-01
High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.
ERIC Educational Resources Information Center
Rikhtegar, Omid; Gholami, Javad
2015-01-01
The purpose of this study was to find out the possible effects of pre-versus post-presentation input flooding via reading on simple past tense acquisition among young Iranian EFL learners. Sixty one elementary EFL learners were divided into two experimental and one control group. The experimental groups were exposed to pre and post presentation…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watts, Christopher A.
In this dissertation the possibility that chaos and simple determinism are governing the dynamics of reversed field pinch (RFP) plasmas is investigated. To properly assess this possibility, data from both numerical simulations and experiment are analyzed. A large repertoire of nonlinear analysis techniques is used to identify low dimensional chaos in the data. These tools include phase portraits and Poincare sections, correlation dimension, the spectrum of Lyapunov exponents and short term predictability. In addition, nonlinear noise reduction techniques are applied to the experimental data in an attempt to extract any underlying deterministic dynamics. Two model systems are used to simulatemore » the plasma dynamics. These are the DEBS code, which models global RFP dynamics, and the dissipative trapped electron mode (DTEM) model, which models drift wave turbulence. Data from both simulations show strong indications of low dimensional chaos and simple determinism. Experimental date were obtained from the Madison Symmetric Torus RFP and consist of a wide array of both global and local diagnostic signals. None of the signals shows any indication of low dimensional chaos or low simple determinism. Moreover, most of the analysis tools indicate the experimental system is very high dimensional with properties similar to noise. Nonlinear noise reduction is unsuccessful at extracting an underlying deterministic system.« less
NASA Astrophysics Data System (ADS)
Aronica, G. T.; Candela, A.
2007-12-01
SummaryIn this paper a Monte Carlo procedure for deriving frequency distributions of peak flows using a semi-distributed stochastic rainfall-runoff model is presented. The rainfall-runoff model here used is very simple one, with a limited number of parameters and practically does not require any calibration, resulting in a robust tool for those catchments which are partially or poorly gauged. The procedure is based on three modules: a stochastic rainfall generator module, a hydrologic loss module and a flood routing module. In the rainfall generator module the rainfall storm, i.e. the maximum rainfall depth for a fixed duration, is assumed to follow the two components extreme value (TCEV) distribution whose parameters have been estimated at regional scale for Sicily. The catchment response has been modelled by using the Soil Conservation Service-Curve Number (SCS-CN) method, in a semi-distributed form, for the transformation of total rainfall to effective rainfall and simple form of IUH for the flood routing. Here, SCS-CN method is implemented in probabilistic form with respect to prior-to-storm conditions, allowing to relax the classical iso-frequency assumption between rainfall and peak flow. The procedure is tested on six practical case studies where synthetic FFC (flood frequency curve) were obtained starting from model variables distributions by simulating 5000 flood events combining 5000 values of total rainfall depth for the storm duration and AMC (antecedent moisture conditions) conditions. The application of this procedure showed how Monte Carlo simulation technique can reproduce the observed flood frequency curves with reasonable accuracy over a wide range of return periods using a simple and parsimonious approach, limited data input and without any calibration of the rainfall-runoff model.
"Compacted" procedures for adults' simple addition: A review and critique of the evidence.
Chen, Yalin; Campbell, Jamie I D
2018-04-01
We review recent empirical findings and arguments proffered as evidence that educated adults solve elementary addition problems (3 + 2, 4 + 1) using so-called compacted procedures (e.g., unconscious, automatic counting); a conclusion that could have significant pedagogical implications. We begin with the large-sample experiment reported by Uittenhove, Thevenot and Barrouillet (2016, Cognition, 146, 289-303), which tested 90 adults on the 81 single-digit addition problems from 1 + 1 to 9 + 9. They identified the 12 very-small addition problems with different operands both ≤ 4 (e.g., 4 + 3) as a distinct subgroup of problems solved by unconscious, automatic counting: These items yielded a near-perfectly linear increase in answer response time (RT) yoked to the sum of the operands. Using the data reported in the article, however, we show that there are clear violations of the sum-counting model's predictions among the very-small addition problems, and that there is no real RT boundary associated with addends ≤4. Furthermore, we show that a well-known associative retrieval model of addition facts-the network interference theory (Campbell, 1995)-predicts the results observed for these problems with high precision. We also review the other types of evidence adduced for the compacted procedure theory of simple addition and conclude that these findings are unconvincing in their own right and only distantly consistent with automatic counting. We conclude that the cumulative evidence for fast compacted procedures for adults' simple addition does not justify revision of the long-standing assumption that direct memory retrieval is ultimately the most efficient process of simple addition for nonzero problems, let alone sufficient to recommend significant changes to basic addition pedagogy.
Golombeck, M A; Dössel, O; Raiser, J
2003-09-01
Numerical field calculations and experimental investigations were performed to examine the heating of the surface of human skin during the application of a new electrode design for the patient return electrode. The new electrode is characterised by an equipotential ring around the central electrode pads. A multi-layer thigh model was used, to which the patient return electrode and the active electrode were connected. The simulation geometry and the dielectric tissue parameters were set according to the frequency of the current. The temperature rise at the skin surface due to the flow of current was evaluated using a two-step numerical solving procedure. The results were compared with experimental thermographical measurements that yielded a mean value of maximum temperature increase of 3.4 degrees C and a maximum of 4.5 degrees C in one test case. The calculated heating patterns agreed closely with the experimental results. However, the calculated mean value in ten different numerical models of the maximum temperature increase of 12.5 K (using a thermodynamic solver) exceeded the experimental value owing to neglect of heat transport by blood flow and also because of the injection of a higher test current, as in the clinical tests. The implementation of a simple worst-case formula that could significantly simplify the numerical process led to a substantial overestimation of the mean value of the maximum skin temperature of 22.4 K and showed only restricted applicability. The application of numerical methods confirmed the experimental assertions and led to a general understanding of the observed heating effects and hotspots. Furthermore, it was possible to demonstrate the beneficial effects of the new electrode design with an equipotential ring. These include a balanced heating pattern and the absence of hotspots.
Cassette, Philippe
2016-03-01
In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ(2) minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Girault, Isabelle; d'Ham, Cedric; Ney, Muriel; Sanchez, Eric; Wajeman, Claire
2012-04-01
Many studies have stressed students' lack of understanding of experiments in laboratories. Some researchers suggest that if students design all or parts of entire experiment, as part of an inquiry-based approach, it would overcome certain difficulties. It requires that a procedure be written for experimental design. The aim of this paper is to describe the characteristics of a procedure in science laboratories, in an educational context. As a starting point, this paper proposes a model in the form of a hierarchical task diagram that gives the general structure of any procedure. This model allows both the analysis of existing procedures and the design of a new inquiry-based approach. The obtained characteristics are further organized into criteria that can help both teachers and students assess a procedure during and after its writing. These results are obtained through two different sets of data. First, the characteristics of procedures are established by analysing laboratory manuals. This allows the organization and type of information in procedures to be defined. This analysis reveals that students are seldom asked to write a full procedure, but sometimes have to specify tasks within a procedure. Secondly, iterative interviews are undertaken with teachers. This leads to the list of criteria to evaluate the procedure.
Pal, Jayanta K; Berwal, Sunil K; Soni, Rupali N
2012-01-01
A simple method for staining of proteins simultaneously on sodium dodecyl sulfate (SDS) polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis is described. A 5% solution of Alta, a commercially available cosmetic preparation, is added in the upper tank buffer during electrophoresis. On completion of electrophoresis, the gel is washed in distilled water and viewed on a white light plate and a transilluminator to photograph the protein profiles. The gel is processed for western blot transfer of proteins onto a nitrocellulose membrane, and upon completion, the protein profiles on the membrane are viewed and photographed as stated above. The membrane can then be processed for immunostaining as per the standard procedure. Thus, the staining procedure using Alta is simple, rapid (without any need of destaining), and cost-effective.
Performance tests and quality control of cathode ray tube displays.
Roehrig, H; Blume, H; Ji, T L; Browne, M
1990-08-01
Spatial resolution, noise, characteristic curve, and absolute luminance are the essential parameters that describe physical image quality of a display. This paper presents simple procedures for assessing the performance of a cathode ray tube (CRT) in terms of these parameters as well as easy set up techniques. The procedures can be used in the environment where the CRT is used. The procedures are based on a digital representation of the Society of Motion Pictures and Television Engineers pattern plus a few simple other digital patterns. Additionally, measurement techniques are discussed for estimating brightness uniformity, veiling glare, and distortion. Apart from the absolute luminance, all performance features can be assessed with an uncalibrated photodetector and the eyes of a human observer. The measurement techniques especially enable the user to perform comparisons of different display systems.
Shen, Yi; Dai, Wei; Richards, Virginia M
2015-03-01
A MATLAB toolbox for the efficient estimation of the threshold, slope, and lapse rate of the psychometric function is described. The toolbox enables the efficient implementation of the updated maximum-likelihood (UML) procedure. The toolbox uses an object-oriented architecture for organizing the experimental variables and computational algorithms, which provides experimenters with flexibility in experimental design and data management. Descriptions of the UML procedure and the UML Toolbox are provided, followed by toolbox use examples. Finally, guidelines and recommendations of parameter configurations are given.
Blade selection for a modern axial-flow compressor
NASA Technical Reports Server (NTRS)
Wright, L. C.
1974-01-01
The procedures leading to successful design of an axial flow compressor are discussed. The three related approaches to cascade selection are: (1) experimental approach which relies on the use of experimental results from identical cascades to satisfy the velocity diagrams calculated, (2) a purely analytical procedure whereby blade shapes are calculated from the theoretical cascade and viscous flow equations, and (3) a semiempirical procedure which used experimental data together with the theoretically derived functional relations to relate the cascade parameters. Diagrams of typical transonic blade sections with uncambered leading edges are presented.
New approach in the quantum statistical parton distribution
NASA Astrophysics Data System (ADS)
Sohaily, Sozha; Vaziri (Khamedi), Mohammad
2017-12-01
An attempt to find simple parton distribution functions (PDFs) based on quantum statistical approach is presented. The PDFs described by the statistical model have very interesting physical properties which help to understand the structure of partons. The longitudinal portion of distribution functions are given by applying the maximum entropy principle. An interesting and simple approach to determine the statistical variables exactly without fitting and fixing parameters is surveyed. Analytic expressions of the x-dependent PDFs are obtained in the whole x region [0, 1], and the computed distributions are consistent with the experimental observations. The agreement with experimental data, gives a robust confirm of our simple presented statistical model.
NASA Astrophysics Data System (ADS)
Billaud, Pierre; Marhaba, Salem; Grillet, Nadia; Cottancin, Emmanuel; Bonnet, Christophe; Lermé, Jean; Vialle, Jean-Louis; Broyer, Michel; Pellarin, Michel
2010-04-01
This article describes a high sensitivity spectrophotometer designed to detect the overall extinction of light by a single nanoparticle (NP) in the 10-4-10-5 relative range, using a transmission measurement configuration. We focus here on the simple and low cost scheme where a white lamp is used as a light source, permitting easy and broadband extinction measurements (300-900 nm). Using a microscope, in a confocal geometry, an increased sensitivity is reached thanks to a modulation of the NP position under the light spot combined with lock-in detection. Moreover, it is shown that this technique gives access to the absolute extinction cross-sections of the single NP provided that the incident electromagnetic field distribution experienced by the NP is accurately characterized. In this respect, an experimental procedure to characterize the light spot profile in the focal plane, using a reference NP as a probe, is also laid out. The validity of this approach is discussed and confirmed by comparing experimental intensity distributions to theoretical calculations taking into account the vector character of the tightly focused beam. The calibration procedure permitting to obtain the absolute extinction cross-section of the probed NP is then fully described. Finally, the force of the present technique is illustrated through selected examples concerning spherical and slightly elongated gold and silver NPs. Absolute extinction measurements are found to be in good consistency with the NP size and shape independently obtained from transmission electron microscopy, showing that spatial modulation spectroscopy is a powerful tool to get an optical fingerprint of the NP.
ERIC Educational Resources Information Center
Miller, Regina M.; And Others
In this study a 4-component procedure designed to decrease a 4-year-old child's noncompliance behaviors was experimentally analyzed as to the effectiveness of the separate components of the package. Once experimental control had been demonstrated and the subject's noncompliance behaviors had been decreased to an acceptable level, separate analyses…
Simple Psychological Interventions for Reducing Pain From Common Needle Procedures in Adults
Boerner, Katelynn E.; Birnie, Kathryn A.; Taddio, Anna; McMurtry, C. Meghan; Noel, Melanie; Shah, Vibhuti; Pillai Riddell, Rebecca
2015-01-01
Background: This systematic review evaluated the effectiveness of simple psychological interventions for managing pain and fear in adults undergoing vaccination or related common needle procedures (ie, venipuncture/venous cannulation). Design/Methods: Databases were searched to identify relevant randomized and quasi-randomized controlled trials. Self-reported pain and fear were prioritized as critically important outcomes. Data were combined using standardized mean difference (SMD) or relative risk (RR) with 95% confidence intervals (CI). Results: No studies involving vaccination met inclusion criteria; evidence was drawn from 8 studies of other common needle procedures (eg, venous cannulation, venipuncture) in adults. Two trials evaluating the impact of neutral signaling of the impending procedure (eg, “ready?”) as compared with signaling of impending pain (eg, “sharp scratch”) demonstrated lower pain when signaled about the procedure (n=199): SMD=−0.97 (95% CI, −1.26, −0.68), after removal of 1 trial where self-reported pain was significantly lower than the other 2 included trials. Two trials evaluated music distraction (n=156) and demonstrated no difference in pain: SMD=0.10 (95% CI, −0.48, 0.27), or fear: SMD=−0.25 (95% CI, −0.61, 0.10). Two trials evaluated visual distraction and demonstrated no difference in pain (n=177): SMD=−0.57 (95% CI, −1.82, 0.68), or fear (n=81): SMD=−0.05 (95% CI, −0.50, 0.40). Two trials evaluating breathing interventions found less pain in intervention groups (n=138): SMD=−0.82 (95% CI, −1.21, −0.43). The quality of evidence across all trials was very low. Conclusions: There are no published studies of simple psychological interventions for vaccination pain in adults. There is some evidence of a benefit from other needle procedures for breathing strategies and neutral signaling of the start of the procedure. There is no evidence for use of music or visual distraction. PMID:26352921
ERIC Educational Resources Information Center
Yamashita, Shuichi; Kashiwaguma, Yasuyuki; Hayashi, Hideko; Pietzner, Verena
2017-01-01
In science classes, students usually learn about the law of definite proportions by the oxidation of copper. However, common procedures usually do not lead to proper results. This leads to confusion among the students because their experimental results do not fit to the theoretical values. Therefore, we invented a new procedure for this experiment…
NASA Astrophysics Data System (ADS)
Hawcroft, David M.
1996-11-01
Courses of organic chemistry frequently include studies of biochemistry and hence of biochemical techniques. Radioisotopes have played a major role in the understanding of metabolic pathways, transport, enzyme activity and other processes. The experiment described in this paper uses simple techniques to illustrate the procedures involved in working with radioisotopes when following a simplified metabolic pathway. Safety considerations are discussed and a list of safety rules is provided, but the experiment itself uses very low levels of a weak beta-emitting isotope (tritium). Plant material is suggested to reduce legal, financial and emotive problems, but the techniques are applicable to all soft-tissued material. The problems involved in data interpretation in radioisotope experiments resulting from radiation quenching are resolved by simple correction calculations, and the merits of using radioisotopes shown by a calculation of the low mass of material being measured. Suggestions for further experiments are given.
Helicopter vibration suppression using simple pendulum absorbers on the rotor blade
NASA Technical Reports Server (NTRS)
Hamouda, M.-N. H.; Pierce, G. A.
1981-01-01
A design procedure is presented for the installation of simple pendulums on the blades of a helicopter rotor to suppress the root reactions. The procedure consists of a frequency response analysis for a hingeless rotor blade excited by a harmonic variation of spanwise airload distributions during forward flight, as well as a concentrated load at the tip. The structural modeling of the blade provides for elastic degrees of freedom in flap and lead-lag bending plus torsion. Simple flap and lead-lag pendulums are considered individually. Using a rational order scheme, the general nonlinear equations of motion are linearized. A quasi-steady aerodynamic representation is used in the formation of the airloads. The solution of the system equations derives from their representation as a transfer matrix. The results include the effect of pendulum tuning on the minimization of the hub reactions.
Lorentz-invariant formulation of Cherenkov radiation by tachyons
NASA Technical Reports Server (NTRS)
Jones, F. C.
1972-01-01
Previous treatments of Cherenkov radiation, electromagnetic and gravitational, by tachyons were in error because the prescription employed to cut off the divergent integral over frequency is not a Lorentz invariant procedure. The resulting equation of motion for the tachyon is therefore not covariant. The proper procedure requires an extended, deformable distribution of charge or mass and yields a particularly simple form for the tachyon's world line, one that could be deduced from simple invariance considerations. It is shown that Cherenkov radiation by tachyons implys their ultimate annihilation with an antitachyon and demonstrates a disturbing property of tachyons, namely the impossibility of specifying arbitrary Cauchy data even in a purely classical theory.
Yi, Gihwan; Choi, Jun-Ho; Lee, Jong-Hee; Jeong, Unggi; Nam, Min-Hee; Yun, Doh-Won; Eun, Moo-Young
2005-01-01
We describe a rapid and simple procedure for homogenizing leaf samples suitable for mini/midi-scale DNA preparation in rice. The methods used tungsten carbide beads and general vortexer for homogenizing leaf samples. In general, two samples can be ground completely within 11.3+/-1.5 sec at one time. Up to 20 samples can be ground at a time using a vortexer attachment. The yields of the DNA ranged from 2.2 to 7.6 microg from 25-150 mg of young fresh leaf tissue. The quality and quantity of DNA was compatible for most of PCR work and RFLP analysis.
Xu, Guojun; Yu, Xinghua; Zhang, Jinxie; Sheng, Yingchao; Liu, Gan; Tao, Wei; Mei, Lin
2016-01-01
One limitation of current biodegradable polymeric nanoparticles (NPs) is the contradiction between functional modification and maintaining formerly excellent bioproperties with simple procedures. Here, we reported a robust aptamer-polydopamine-functionalized mannitol-functionalized poly(lactide-co-glycolide) (M-PLGA)-D-α-tocopheryl polyethylene glycol 1000 succinate (TPGS) nanoformulation (Apt-pD-NPs) for the delivery of docetaxel (DTX) with enhanced cervical cancer therapy effects. The novel DTX-loaded Apt-pD-NPs possess satisfactory advantages: 1) increased drug loading content and encapsulation efficiency induced by star-shaped copolymer M-PLGA-TPGS; 2) significant active targeting effect caused by conjugated AS1411 aptamers; and 3) excellent long-term compatibility by incorporation of TPGS. Therefore, with simple preparation procedures and excellent bioproperties, the new functionalized Apt-pD-NPs could maximally increase the local effective drug concentration on tumor sites, achieving enhanced treatment effectiveness and minimizing side effects. In a word, the robust DTX-loaded Apt-pD-NPs could be used as potential nanotherapeutics for cervical cancer treatment, and the aptamer-polydopamine modification strategy could be a promising method for active targeting of cancer therapy with simple procedures.
A Simple Acronym for Doing Calculus: CAL
ERIC Educational Resources Information Center
Hathaway, Richard J.
2008-01-01
An acronym is presented that provides students a potentially useful, unifying view of the major topics covered in an elementary calculus sequence. The acronym (CAL) is based on viewing the calculus procedure for solving a calculus problem P* in three steps: (1) recognizing that the problem cannot be solved using simple (non-calculus) techniques;…
More Powerful Tests of Simple Interaction Contrasts in the Two-Way Factorial Design
ERIC Educational Resources Information Center
Hancock, Gregory R.; McNeish, Daniel M.
2017-01-01
For the two-way factorial design in analysis of variance, the current article explicates and compares three methods for controlling the Type I error rate for all possible simple interaction contrasts following a statistically significant interaction, including a proposed modification to the Bonferroni procedure that increases the power of…
A Simple Hypnotic Approach to Treat Test Anxiety in Medical Students and Residents.
ERIC Educational Resources Information Center
Hebert, Stephen W.
1984-01-01
A simple hypnotic procedure to treat test anxiety is described that was used successfully with medical students and residents at the Wake Forest University Medical Center. A light trace is obtained and then the student is told to take such a hypnotic "journey" the evening prior to the test. (MLW)
Quantitation & Case-Study-Driven Inquiry to Enhance Yeast Fermentation Studies
ERIC Educational Resources Information Center
Grammer, Robert T.
2012-01-01
We propose a procedure for the assay of fermentation in yeast in microcentrifuge tubes that is simple and rapid, permitting assay replicates, descriptive statistics, and the preparation of line graphs that indicate reproducibility. Using regression and simple derivatives to determine initial velocities, we suggest methods to compare the effects of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lutjeboer, Jacob, E-mail: j.lutjeboer@lumc.nl; Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl, E-mail: mburgmans@hotmail.com; Chung, Kaman, E-mail: kaman.chung10@gmail.com
PurposeInterventional radiology (IR) procedures are associated with high rates of preparation and planning errors. In many centers, pre-procedural consultation and screening of patients is performed by referring physicians. Interventional radiologists have better knowledge about procedure details and risks, but often only get acquainted with the patient in the procedure room. We hypothesized that patient safety (PS) and patient satisfaction (PSAT) in elective IR procedures would improve by implementation of a pre-procedural visit to an outpatient IR clinic.Material and MethodsIRB approval was obtained and informed consent was waived. PS and PSAT were measured in patients undergoing elective IR procedures before (controlmore » group; n = 110) and after (experimental group; n = 110) implementation of an outpatient IR clinic. PS was measured as the number of process deviations. PSAT was assessed using a questionnaire measuring Likert scores of three dimensions: interpersonal care aspects, information/communication, and patient participation. Differences in PS and PSAT between the two groups were compared using an independent t test.ResultsThe average number of process deviations per patient was 0.39 in the control group compared to 0.06 in the experimental group (p < 0.001). In 9.1 % patients in the control group, no legal informed consent was obtained compared to 0 % in the experimental group. The mean overall Likert score was significantly higher in the experimental group compared to the control group: 2.68 (SD 0.314) versus 2.48 (SD 0.381) (p < 0.001).ConclusionPS and PSAT improve significantly if patients receive consultation and screening in an IR outpatient clinic prior to elective IR procedures.« less
Direct Simple Shear Test Data Analysis using Jupyter Notebooks on DesignSafe-CI
NASA Astrophysics Data System (ADS)
Eslami, M.; Esteva, M.; Brandenberg, S. J.
2017-12-01
Due to the large number of files and their complex structure, managing data generated during natural hazards experiments requires scalable and specialized tools. DesignSafe-CI (https://www.designsafe-ci.org/) is a web-based research platform that provides computational tools to analyze, curate, and publish critical data for natural hazards research making it understandable and reusable. We present a use case from a series of Direct Simple Shear (DSS) experiments in which we used DS-CI to post-process, visualize, publish, and enable further analysis of the data. Current practice in geotechnical design against earthquakes relies on the soil's plasticity index (PI) to assess liquefaction susceptibility, and cyclic softening triggering procedures, although, quite divergent recommendations on recommended levels of plasticity can be found in the literature for these purposes. A series of cyclic and monotonic direct simple shear experiments was conducted on three low-plasticity fine-grained mixtures at the same plasticity index to examine the effectiveness of the PI in characterization of these types of materials. Results revealed that plasticity index is an insufficient indicator of the cyclic behavior of low-plasticity fine-grained soils, and corrections for pore fluid chemistry and clay minerology may be necessary for future liquefaction susceptibility and cyclic softening assessment procedures. Each monotonic, or cyclic experiment contains two stages; consolidation and shear, which include time series of load, displacement, and corresponding stresses and strains, as well as equivalent excess pore-water pressure. Using the DS-CI curation pipeline we categorized the data to display and describe the experiment's structure and files corresponding to each stage of the experiments. Two separate notebooks in Python 3 were created using the Jupyter application available in DS-CI. A data plotter aids visualizing the experimental data in relation to the sensor from which it was generated. The analysis notebook allows combining outcomes of multiple tests, conducting diverse analyses to find critical parameters, and developing plots at arbitrary strain levels. Using the platform aids both researchers work with the data and those reusing it.
The simple procedure for the fluxgate magnetometers calibration
NASA Astrophysics Data System (ADS)
Marusenkov, Andriy
2014-05-01
The fluxgate magnetometers are widely used in geophysics investigations including the geomagnetic field monitoring at the global network of geomagnetic observatories as well as for electromagnetic sounding of the Earth's crust conductivity. For solving these tasks the magnetometers have to be calibrated with an appropriate level of accuracy. As a particular case, the ways to satisfy the recent requirements to the scaling and orientation errors of 1-second INTERNAGNET magnetometers are considered in the work. The goal of the present study was to choose a simple and reliable calibration method for estimation of scale factors and angular errors of the three-axis magnetometers in the field. There are a large number of the scalar calibration methods, which use a free rotation of the sensor in the calibration field followed by complicated data processing procedures for numerical solution of the high-order equations set. The chosen approach also exploits the Earth's magnetic field as a calibrating signal, but, in contrast to other methods, the sensor has to be oriented in some particular positions in respect to the total field vector, instead of the sensor free rotation. This allows to use very simple and straightforward linear computation formulas and, as a result, to achieve more reliable estimations of the calibrated parameters. The estimation of the scale factors is performed by the sequential aligning of each component of the sensor in two positions: parallel and anti-parallel to the Earth's magnetic field vector. The estimation of non-orthogonality angles between each pair of components is performed after sequential aligning of the components at the angles +/- 45 and +/- 135 degrees of arc in respect to the total field vector. Due to such four positions approach the estimations of the non-orthogonality angles are invariant to the zero offsets and non-linearity of transfer functions of the components. The experimental justifying of the proposed method by means of the Coil Calibration system reveals, that the achieved accuracy (<0.04 % for scale factors and 0.03 degrees of arc for angle errors) is sufficient for many applications, particularly for satisfying the INTERMAGNET requirements to 1-second instruments.
Hubert, Ph; Nguyen-Huu, J-J; Boulanger, B; Chapuzet, E; Chiap, P; Cohen, N; Compagnon, P-A; Dewé, W; Feinberg, M; Lallier, M; Laurentie, M; Mercier, N; Muzard, G; Nivet, C; Valat, L
2004-11-15
This paper is the first part of a summary report of a new commission of the Société Française des Sciences et Techniques Pharmaceutiques (SFSTP). The main objective of this commission was the harmonization of approaches for the validation of quantitative analytical procedures. Indeed, the principle of the validation of theses procedures is today widely spread in all the domains of activities where measurements are made. Nevertheless, this simple question of acceptability or not of an analytical procedure for a given application, remains incompletely determined in several cases despite the various regulations relating to the good practices (GLP, GMP, ...) and other documents of normative character (ISO, ICH, FDA, ...). There are many official documents describing the criteria of validation to be tested, but they do not propose any experimental protocol and limit themselves most often to the general concepts. For those reasons, two previous SFSTP commissions elaborated validation guides to concretely help the industrial scientists in charge of drug development to apply those regulatory recommendations. If these two first guides widely contributed to the use and progress of analytical validations, they present, nevertheless, weaknesses regarding the conclusions of the performed statistical tests and the decisions to be made with respect to the acceptance limits defined by the use of an analytical procedure. The present paper proposes to review even the bases of the analytical validation for developing harmonized approach, by distinguishing notably the diagnosis rules and the decision rules. This latter rule is based on the use of the accuracy profile, uses the notion of total error and allows to simplify the approach of the validation of an analytical procedure while checking the associated risk to its usage. Thanks to this novel validation approach, it is possible to unambiguously demonstrate the fitness for purpose of a new method as stated in all regulatory documents.
Non-Procedural Languages for Information Resource Management.
ERIC Educational Resources Information Center
Bearley, William L.
The future of information resources management requires new approaches to implementing systems which will include a type of data base management that frees users to solve data processing problems logically by telling the system what they want, together with powerful non-procedural languages that will permit communication in simple, concise…
Adjusting the Stems Regional Forest Growth Model to Improve Local Predictions
W. Brad Smith
1983-01-01
A simple procedure using double sampling is described for adjusting growth in the STEMS regional forest growth model to compensate for subregional variations. Predictive accuracy of the STEMS model (a distance-independent, individual tree growth model for Lake States forests) was improved by using this procedure
Classical conditioning of the eyeblink reflex is a relatively simple procedure for studying associative learning that was first developed for use with human subjects more than half a century ago. The use of this procedure in laboratory animals by psychologists and neuro-scientist...
How to Use Chromatography as a Science Teaching Aid.
ERIC Educational Resources Information Center
Ganis, Frank M.
Presented are five procedures which permit the effective teaching of chromatography with equipment which is readily available, economical, and simple in design. The first procedure involves a study of solute partition in two immiscible solvents and of countercurrent distribution. The second illustrates the use of unidimensional ascending paper…
Speed and Accuracy in the Processing of False Statements About Semantic Information.
ERIC Educational Resources Information Center
Ratcliff, Roger
1982-01-01
A standard reaction time procedure and a response signal procedure were used on data from eight experiments on semantic verifications. Results suggest that simple models of the semantic verification task that assume a single yes/no dimension on which discrimination is made are not correct. (Author/PN)
An analysis of ratings: A guide to RMRATE
Thomas C. Brown; Terry C. Daniel; Herbert W. Schroeder; Glen E. Brink
1990-01-01
This report describes RMRATE, a computer program for analyzing rating judgments. RMRATE scales ratings using several scaling procedures, and compares the resulting scale values. The scaling procedures include the median and simple mean, standardized values, scale values based on Thurstone's Law of Categorical Judgment, and regression-based values. RMRATE also...
Using Statistical Process Control to Make Data-Based Clinical Decisions.
ERIC Educational Resources Information Center
Pfadt, Al; Wheeler, Donald J.
1995-01-01
Statistical process control (SPC), which employs simple statistical tools and problem-solving techniques such as histograms, control charts, flow charts, and Pareto charts to implement continual product improvement procedures, can be incorporated into human service organizations. Examples illustrate use of SPC procedures to analyze behavioral data…
New Method for Evaluation of Virucidal Activity of Antiseptics and Disinfectants
Papageorgiou, Georgios T.; Mocé-Llivina, Laura; Jofre, Juan
2001-01-01
Counting culturable viruses adsorbed to cellulose nitrate filters (the VIRADEN method) is proposed as a simple procedure for the evaluation of the virucidal activity of antiseptics and disinfectants. The virucidal activities of two different doses of iodine, chlorine, glutaraldehyde, and chlorhexidine digluconate on poliovirus 1 were tested with a standardized procedure and with the VIRADEN method. The two procedures assayed provided similar results. PMID:11722944
Rolider, A; Van Houten, R
1985-01-01
The effects of a movement suppression time-out, which involved punishing any movement or verbalization while a client is in the time-out area, were evaluated in four experiments. The first experiment examined the effects of a DRO procedure and movement suppression plus DRO in suppressing self-injurious behavior in a psychotic child in three different situations. In Experiment 2, the results of the previous experiment were replicated with two dangerous behaviors in a second psychotic child. In a third experiment, movement suppression plus DRO was compared with contingent restraint in reducing inappropriate poking behavior in two settings. The movement suppression procedure eliminated poking whereas contingent restraint had little effect. In the final experiment, movement suppression time-out alone was compared with exclusionary time-out alone and simple corner time-out alone. Self-stimulation occurred at high levels during the exclusionary and simple corner time-out procedures. Self-stimulation was either suppressed or reduced during movement suppression time-out. The movement suppression time-out procedure produced a larger reduction in the target behavior in all three children. The effectiveness of the movement suppression procedure was explained in terms of the suppression of self-stimulation while the time-out procedure was being applied.
NASA Astrophysics Data System (ADS)
Di Capua, R.; Offi, F.; Fontana, F.
2014-07-01
Exponential decay is a prototypical functional behaviour for many physical phenomena, and therefore it deserves great attention in physics courses at an academic level. The absorption of the electromagnetic radiation that propagates in a dissipative medium provides an example of the decay of light intensity, as stated by the law of Lambert-Beer-Bourguer. We devised a very simple experiment to check this law. The experimental setup, its realization, and the data analysis of the experiment are definitely simple. Our main goal was to create an experiment that is accessible to all students, including those in their first year of academic courses and those with poorly equipped laboratories. As illustrated in this paper, our proposal allowed us to develop a deep discussion about some general mathematical and numerical features of exponential decay. Furthermore, the special setup of the absorbing medium (sliced in finite thickness slabs) and the experimental outcomes allow students to understand the transition from the discrete to the continuum approach in experimental physics.
Experimental assessment of advanced Stirling component concepts
NASA Technical Reports Server (NTRS)
Ziph, B.
1985-01-01
The results of an experimental assessment of some advanced Stirling engine component concepts are presented. High performance piston rings, reciprocating oil scrapers and heat pipes with getters and with mechanical couplings were tested. The tests yielded the following results: (1) Bonded, split, pumping piston rings, in preliminary testing, proved a promising concept, exhibiting low leakage and friction losses. Solid piston rings proved impractical in view of their sensitivity to the operating temperature; (2) A babbit oil scraper in a compliant housing performed well in atmospheric endurance testing. In pressurized tests the scraper did not perform well as a containment seal. The latter tests suggest modifications which may adapt Ti successfully to that application; and (3) Heat pipe endurance tests indicated the adequacy of simple, inexpensive fabrication and filling procedures. Getters were provided to increase the tolerance of the heat pipes to the presence of air and commercially available couplings were demonstrated to be suitable for heat pipe application. In addition to the above tests, the program also included a design effort for a split shaft applicable to a swashplate driven engine with a pressurized crank-case. The design is aimed, and does accomplish, an increase in component life to more than 10,000 hours.
Generalized energy measurements and modified transient quantum fluctuation theorems
NASA Astrophysics Data System (ADS)
Watanabe, Gentaro; Venkatesh, B. Prasanna; Talkner, Peter
2014-05-01
Determining the work which is supplied to a system by an external agent provides a crucial step in any experimental realization of transient fluctuation relations. This, however, poses a problem for quantum systems, where the standard procedure requires the projective measurement of energy at the beginning and the end of the protocol. Unfortunately, projective measurements, which are preferable from the point of view of theory, seem to be difficult to implement experimentally. We demonstrate that, when using a particular type of generalized energy measurements, the resulting work statistics is simply related to that of projective measurements. This relation between the two work statistics entails the existence of modified transient fluctuation relations. The modifications are exclusively determined by the errors incurred in the generalized energy measurements. They are universal in the sense that they do not depend on the force protocol. Particularly simple expressions for the modified Crooks relation and Jarzynski equality are found for Gaussian energy measurements. These can be obtained by a sequence of sufficiently many generalized measurements which need not be Gaussian. In accordance with the central limit theorem, this leads to an effective error reduction in the individual measurements and even yields a projective measurement in the limit of infinite repetitions.
Monolithic Cylindrical Fused Silica Resonators with High Q Factors
Pan, Yao; Wang, Dongya; Wang, Yanyan; Liu, Jianping; Wu, Suyong; Qu, Tianliang; Yang, Kaiyong; Luo, Hui
2016-01-01
The cylindrical resonator gyroscope (CRG) is a typical Coriolis vibratory gyroscope whose performance is determined by the Q factor and frequency mismatch of the cylindrical resonator. Enhancing the Q factor is crucial for improving the rate sensitivity and noise performance of the CRG. In this paper, for the first time, a monolithic cylindrical fused silica resonator with a Q factor approaching 8 × 105 (ring-down time over 1 min) is reported. The resonator is made of fused silica with low internal friction and high isotropy, with a diameter of 25 mm and a center frequency of 3974.35 Hz. The structure of the resonator is first briefly introduced, and then the experimental non-contact characterization method is presented. In addition, the post-fabrication experimental procedure of Q factor improvement, including chemical and thermal treatment, is demonstrated. The Q factor improvement by both treatments is compared and the primary loss mechanism is analyzed. To the best of our knowledge, the work presented in this paper represents the highest reported Q factor for a cylindrical resonator. The proposed monolithic cylindrical fused silica resonator may enable high performance inertial sensing with standard manufacturing process and simple post-fabrication treatment. PMID:27483263
NASA Astrophysics Data System (ADS)
Yang, Tao; Zhang, Qi; Hao, Yue; Zhou, Xin-hui; Yi, Ming-dong; Wei, Wei; Huang, Wei; Li, Xing-ao
2017-10-01
A multiple-input multiple-output visible light communication (VLC) system based on disorder dispersion components is presented. Instead of monochromatic sources and large size photodetectors used in the traditional VLC systems, broadband sources with different spectra act as the transmitters and a compact imaging chip sensor accompanied by a disorder dispersion component and a calculating component serve as the receivers in the proposed system. This system has the merits of small size, more channels, simple structure, easy integration, and low cost. Simultaneously, the broadband sources are suitable to act as illumination sources for their white color. A regularized procedure is designed to solve a matrix equation for decoding the signals at the receivers. A proof-of-concept experiment using on-off keying modulation has been done to prove the feasibility of the design. The experimental results show that the signals decoded by the receivers fit well with those generated from the transmitters, but the bit error ratio is increased with the number of the signal channels. The experimental results can be further improved using a high-speed charge-coupled device, decreasing noises, and increasing the distance between the transmitters and the receivers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Govind, R.; Bishop, D.F.
1996-12-31
This paper provides an overview of air biofiltration with experimental data on the performance of peat/compost, pelletized packed bed and structured media biofilters. It is shown that use of high surface area per unit volume structured media results in higher contaminant treatment rates per unit biofilter volume. Peat/compost biofilters exhibit lower removal efficiencies at high (> 100 ppmv) inlet contaminant concentrations and require control of media moisture content. Increase of temperature results in increasing biodegradation rates. It is shown that use of structured ceramic media allows effective control of biomass buildup by continuous removal of biomass from the biofilter mediamore » and that the biomass removal rate depends on nutrient flowrate. An experimental system is presented which enables biofilm kinetics to be determined and a simple biofilter model is developed in this paper. A group contribution approach has been developed to estimate biokinetic parameter which allows biofiltration effectiveness to be determined for a variety of volatile organic compounds (VOCs). Finally, a procedure is presented, illustrated by an example, which is used to develop an integrated process for effective treatment of air contaminants. 22 refs., 12 figs., 4 tabs.« less
An experiment on radioactive equilibrium and its modelling using the ‘radioactive dice’ approach
NASA Astrophysics Data System (ADS)
Santostasi, Davide; Malgieri, Massimiliano; Montagna, Paolo; Vitulo, Paolo
2017-07-01
In this article we describe an educational activity on radioactive equilibrium we performed with secondary school students (17-18 years old) in the context of a vocational guidance stage for talented students at the Department of Physics of the University of Pavia. Radioactive equilibrium is investigated experimentally by having students measure the activity of 214Bi from two different samples, obtained using different preparation procedures from an uraniferous rock. Students are guided in understanding the mathematical structure of radioactive equilibrium through a modelling activity in two parts. Before the lab measurements, a dice game, which extends the traditional ‘radioactive dice’ activity to the case of a chain of two decaying nuclides, is performed by students divided into small groups. At the end of the laboratory work, students design and run a simple spreadsheet simulation modelling the same basic radioactive chain with user defined decay constants. By setting the constants to realistic values corresponding to nuclides of the uranium decay chain, students can deepen their understanding of the meaning of the experimental data, and also explore the difference between cases of non-equilibrium, transient and secular equilibrium.
Fragmentation modeling of a resin bonded sand
NASA Astrophysics Data System (ADS)
Hilth, William; Ryckelynck, David
2017-06-01
Cemented sands exhibit a complex mechanical behavior that can lead to sophisticated models, with numerous parameters without real physical meaning. However, using a rather simple generalized critical state bonded soil model has proven to be a relevant compromise between an easy calibration and good results. The constitutive model formulation considers a non-associated elasto-plastic formulation within the critical state framework. The calibration procedure, using standard laboratory tests, is complemented by the study of an uniaxial compression test observed by tomography. Using finite elements simulations, this test is simulated considering a non-homogeneous 3D media. The tomography of compression sample gives access to 3D displacement fields by using image correlation techniques. Unfortunately these fields have missing experimental data because of the low resolution of correlations for low displacement magnitudes. We propose a recovery method that reconstructs 3D full displacement fields and 2D boundary displacement fields. These fields are mandatory for the calibration of the constitutive parameters by using 3D finite element simulations. The proposed recovery technique is based on a singular value decomposition of available experimental data. This calibration protocol enables an accurate prediction of the fragmentation of the specimen.
Tunable two-dimensional liquid gradient refractive index (L-GRIN) lens for variable light focusing.
Huang, Hua; Mao, Xiaole; Lin, Sz-Chin Steven; Kiraly, Brian; Huang, Yiping; Huang, Tony Jun
2010-09-21
We report a two-dimensional (2D) tunable liquid gradient refractive index (L-GRIN) lens for variable focusing of light in the out-of-plane direction. This lens focuses a light beam through a liquid medium with a 2D hyperbolic secant (HS) refractive index gradient. The refractive index gradient is established in a microfluidic chamber through the diffusion between two fluids with different refractive indices, i.e. CaCl(2) solution and deionized (DI) water. The 2D HS refractive index profile and subsequently the focal length of the L-GRIN lens can be tuned by changing the ratio of the flow rates of the CaCl(2) solution and DI water. The focusing effect is experimentally characterized through side-view and top-view image analysis, and the experimental data match well with the results from ray-tracing optical simulations. Advantages of the 2D L-GRIN lens include simple device fabrication procedure, low fluid consumption rate, convenient lens-tuning mechanism, and compatibility with existing microfluidic devices. We expect that with further optimizations, this 2D L-GRIN lens can be used in many optics-based lab-on-a-chip applications.
NASA Astrophysics Data System (ADS)
Parekh, Bhaumik Kamlesh
Lithium-Ion batteries have become a popular choice for use in energy storage systems in electric vehicles (EV) and Hybrid electric vehicles (HEV) because of high power and high energy density. But the use of EV and HEV in all climates demands for a battery thermal management system (BTMS) since temperature effects their performance, cycle life and, safety. Hence the BTMS plays a crucial role in the performance of EV and HEV. In this paper, three thermal management systems are studied: (a) simple aluminum as heat spreader material, (b) heat pipes as heat spreader, and (c) advanced combined solid state thermoelectric heat pump (TE) and heat pipe system; these will be subsequently referred to as Design A, B and C, respectively. A detailed description of the designs and the experimental setup is presented. The experimental procedure is divided into two broad categories: Cooling mode and Warming-up mode. Cooling mode covers the conditions when a BTMS is responsible to cool the battery pack through heat dissipation and Warming-up mode covers the conditions when the BTMS is responsible to warm the battery pack in a low temperature ambient condition, maintaining a safe operating temperature of the battery pack in both modes. The experimental procedure analyzes the thermal management system by evaluating the effect of each variable like heat sink area, battery heat generation rate, cooling air temperature, air flow rate and TE power on parameters like maximum temperature of the battery pack (T max), maximum temperature difference (DeltaT) and, heat transfer through heat sink/cooling power of TE (Q c). The results show that Design C outperforms Design A and Design B in spite of design issues which reduce its efficiency, but can still be improved to achieve better performance.
Conducting Miller-Urey Experiments
NASA Technical Reports Server (NTRS)
Parker, Eric Thomas; Cleaves, Henderson James; Burton, Aaron S.; Glavin, Daniel P.; Dworkin, Jason; Zhou, Manshui; Bada, Jeffrey L.; Fernandez, Facundo M.
2014-01-01
In 1953, Stanley Miller reported the production of biomolecules from simple gaseous starting materials, using apparatus constructed to simulate the primordial Earth's atmosphere-ocean system. Miller introduced 200 ml of water, 100 mmHg of H2, 200mmHg of CH4, and 200mmHg of NH3 into the apparatus, then subjected this mixture, under reflux, to an electric discharge for a week, while the water was simultaneously heated. The purpose of this manuscript is to provide the reader with a general experimental protocol that can be used to conduct a Miller-Urey type spark discharge experiment, using a simplified 3 L reaction flask. Since the experiment involves exposing inflammable gases to a high voltage discharge, it is worth highlighting important steps that reduce the risk of explosion. The general procedures described in this work can be extrapolated to design and conduct a wide variety of electric discharge experiments simulating primitive planetary environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hepworth, H.K.; Davidson, J.S.; Hooyman, J.L.
1997-03-01
Commercially available admixtures have been developed for placing traditional concrete products under water. This paper evaluates adapting anti-washout admixture (AWA) and high range water reducing admixture (HRWRA) products to enhance controlled low-strength materials (CLSMs) for underwater placement. A simple experimental scale model (based on dynamic and geometric similitude) of typical grout pump emplacement equipment has been developed to determine the percentage of cementing material washed out. The objective of this study was to identify proportions of admixtures and underwater CLSM emplacement procedures which would minimize the cross-contamination of the displaced water while maintaining the advantages of CLSM. Since the displacedmore » water from radioactively contaminated systems must be subsequently treated prior to release to the environment, the amount of cross-contamination is important for cases in which cementing material could form hard sludges in a water treatment facility and contaminate the in-place CLSM stabilization medium.« less
Fuzzy observer-based control for maximum power-point tracking of a photovoltaic system
NASA Astrophysics Data System (ADS)
Allouche, M.; Dahech, K.; Chaabane, M.; Mehdi, D.
2018-04-01
This paper presents a novel fuzzy control design method for maximum power-point tracking (MPPT) via a Takagi and Sugeno (TS) fuzzy model-based approach. A knowledge-dynamic model of the PV system is first developed leading to a TS representation by a simple convex polytopic transformation. Then, based on this exact fuzzy representation, a H∞ observer-based fuzzy controller is proposed to achieve MPPT even when we consider varying climatic conditions. A specified TS reference model is designed to generate the optimum trajectory which must be tracked to ensure maximum power operation. The controller and observer gains are obtained in a one-step procedure by solving a set of linear matrix inequalities (LMIs). The proposed method has been compared with some classical MPPT techniques taking into account convergence speed and tracking accuracy. Finally, various simulation and experimental tests have been carried out to illustrate the effectiveness of the proposed TS fuzzy MPPT strategy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Xu; Islam, Ahmad E.; Seabron, Eric
2015-04-07
Aligned arrays of semiconducting single-walled carbon nanotubes (s-SWNTs) represent ideal configurations for use of this class of material in high performance electronics. Development of means for removing the metallic SWNTs (m-SWNTs) in as-grown arrays represents an essential challenge. Here, we introduce a simple scheme that achieves this type of purification using direct, selective current injection through interdigitated electrodes into the m-SWNTs, to allow their complete removal using processes of thermocapillarity and dry etching. Experiments and numerical simulations establish the fundamental aspects that lead to selectivity in this process, thereby setting design rules for optimization. Single-step purification of arrays that includemore » thousands of SWNTs demonstrates the effectiveness and simplicity of the procedures. The result is a practical route to large-area aligned arrays of purely s-SWNTs with low-cost experimental setups.« less
A multiparallel bioreactor for the cultivation of mammalian cells in a 3D-ceramic matrix.
Goralczyk, Vicky; Driemel, Gregor; Bischof, Andreas; Peter, Andrea; Berthold, Almuth; Kroh, Lothar; Blessing, Lucienne; Schubert, Helmut; King, Rudibert
2010-01-01
For adherently growing cells, cultivation is limited by the provided growth surface. Excellent surface-to-volume ratios are found in highly porous matrices, which have to face the challenge of nutrient supply inside the matrices' caverns. Therefore, perfusion strategies are recommended which often have to deal with the need of developing an encompassing bioreactor periphery. We present a modular bioreactor system based on a porous ceramic matrix that enables the supply of cells with oxygen and nutrients by perfusion. The present version of the reactor system focuses on simple testing of various inoculation and operation modes. Moreover, it can be used to efficiently test different foam structures. Protocols are given to set-up the system together with handling procedures for long-time cultivation of a CHO cell line. Experimental results confirm vital growth of cells inside the matrices' caverns.
Giresi, Paul G.; Kim, Jonghwan; McDaniell, Ryan M.; Iyer, Vishwanath R.; Lieb, Jason D.
2007-01-01
DNA segments that actively regulate transcription in vivo are typically characterized by eviction of nucleosomes from chromatin and are experimentally identified by their hypersensitivity to nucleases. Here we demonstrate a simple procedure for the isolation of nucleosome-depleted DNA from human chromatin, termed FAIRE (Formaldehyde-Assisted Isolation of Regulatory Elements). To perform FAIRE, chromatin is crosslinked with formaldehyde in vivo, sheared by sonication, and phenol-chloroform extracted. The DNA recovered in the aqueous phase is fluorescently labeled and hybridized to a DNA microarray. FAIRE performed in human cells strongly enriches DNA coincident with the location of DNaseI hypersensitive sites, transcriptional start sites, and active promoters. Evidence for cell-type–specific patterns of FAIRE enrichment is also presented. FAIRE has utility as a positive selection for genomic regions associated with regulatory activity, including regions traditionally detected by nuclease hypersensitivity assays. PMID:17179217
Optimization of Compton-suppression and summing schemes for the TIGRESS HPGe detector array
NASA Astrophysics Data System (ADS)
Schumaker, M. A.; Svensson, C. E.; Andreoiu, C.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Boston, A. J.; Chakrawarthy, R. S.; Churchman, R.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Jones, B.; Maharaj, R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Sarazin, F.; Scraggs, H. C.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.
2007-04-01
Methods of optimizing the performance of an array of Compton-suppressed, segmented HPGe clover detectors have been developed which rely on the physical position sensitivity of both the HPGe crystals and the Compton-suppression shields. These relatively simple analysis procedures promise to improve the precision of experiments with the TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS). Suppression schemes will improve the efficiency and peak-to-total ratio of TIGRESS for high γ-ray multiplicity events by taking advantage of the 20-fold segmentation of the Compton-suppression shields, while the use of different summing schemes will improve results for a wide range of experimental conditions. The benefits of these methods are compared for many γ-ray energies and multiplicities using a GEANT4 simulation, and the optimal physical configuration of the TIGRESS array under each set of conditions is determined.
A technique for computation of noise temperature due to a beam waveguide shroud
NASA Technical Reports Server (NTRS)
Veruttipong, W.; Franco, M. M.
1993-01-01
Direct analytical computation of the noise temperature of real beam waveguide (BWG) systems, including all mirrors and the surrounding shroud, is an extremely complex problem and virtually impossible to achieve. Yet the DSN antennas are required to be ultra low-noise in order to be effective, and a reasonably accurate prediction is essential. This article presents a relatively simple technique to compute a real BWG system noise temperature by combining analytical techniques with data from experimental tests. Specific expressions and parameters for X-band (8.45-GHz) BWG noise computation are obtained for DSS 13 and DSS 24, now under construction. These expressions are also valid for various conditions of the BWG feed systems, including horn sizes and positions, and mirror sizes, curvatures, and positions. Parameters for S- and Ka-bands (2.3 and 32.0 GHz) have not been determined; however, those can be obtained following the same procedure as for X-band.
Vácha, Robert; Megyes, Tunde; Bakó, Imre; Pusztai, László; Jungwirth, Pavel
2009-04-23
Results from molecular dynamics simulations of aqueous hydroxide of varying concentrations have been compared with experimental structural data. First, the polarizable POL3 model was verified against neutron scattering using a reverse Monte Carlo fitting procedure. It was found to be competitive with other simple water models and well suited for combining with hydroxide ions. Second, a set of four polarizable models of OH- were developed by fitting against accurate ab initio calculations for small hydroxide-water clusters. All of these models were found to provide similar results that robustly agree with structural data from X-ray scattering. The present force field thus represents a significant improvement over previously tested nonpolarizable potentials. Although it cannot in principle capture proton hopping and can only approximately describe the charge delocalization within the immediate solvent shell around OH-, it provides structural data that are almost entirely consistent with data obtained from scattering experiments.
Computational design of a self-assembling symmetrical β-propeller protein.
Voet, Arnout R D; Noguchi, Hiroki; Addy, Christine; Simoncini, David; Terada, Daiki; Unzai, Satoru; Park, Sam-Yong; Zhang, Kam Y J; Tame, Jeremy R H
2014-10-21
The modular structure of many protein families, such as β-propeller proteins, strongly implies that duplication played an important role in their evolution, leading to highly symmetrical intermediate forms. Previous attempts to create perfectly symmetrical propeller proteins have failed, however. We have therefore developed a new and rapid computational approach to design such proteins. As a test case, we have created a sixfold symmetrical β-propeller protein and experimentally validated the structure using X-ray crystallography. Each blade consists of 42 residues. Proteins carrying 2-10 identical blades were also expressed and purified. Two or three tandem blades assemble to recreate the highly stable sixfold symmetrical architecture, consistent with the duplication and fusion theory. The other proteins produce different monodisperse complexes, up to 42 blades (180 kDa) in size, which self-assemble according to simple symmetry rules. Our procedure is suitable for creating nano-building blocks from different protein templates of desired symmetry.
Determination of equivalent sound speed profiles for ray tracing in near-ground sound propagation.
Prospathopoulos, John M; Voutsinas, Spyros G
2007-09-01
The determination of appropriate sound speed profiles in the modeling of near-ground propagation using a ray tracing method is investigated using a ray tracing model which is capable of performing axisymmetric calculations of the sound field around an isolated source. Eigenrays are traced using an iterative procedure which integrates the trajectory equations for each ray launched from the source at a specific direction. The calculation of sound energy losses is made by introducing appropriate coefficients to the equations representing the effect of ground and atmospheric absorption and the interaction with the atmospheric turbulence. The model is validated against analytical and numerical predictions of other methodologies for simple cases, as well as against measurements for nonrefractive atmospheric environments. A systematic investigation for near-ground propagation in downward and upward refractive atmosphere is made using experimental data. Guidelines for the suitable simulation of the wind velocity profile are derived by correlating predictions with measurements.
Manipulation of Unknown Objects to Improve the Grasp Quality Using Tactile Information.
Montaño, Andrés; Suárez, Raúl
2018-05-03
This work presents a novel and simple approach in the area of manipulation of unknown objects considering both geometric and mechanical constraints of the robotic hand. Starting with an initial blind grasp, our method improves the grasp quality through manipulation considering the three common goals of the manipulation process: improving the hand configuration, the grasp quality and the object positioning, and, at the same time, prevents the object from falling. Tactile feedback is used to obtain local information of the contacts between the fingertips and the object, and no additional exteroceptive feedback sources are considered in the approach. The main novelty of this work lies in the fact that the grasp optimization is performed on-line as a reactive procedure using the tactile and kinematic information obtained during the manipulation. Experimental results are shown to illustrate the efficiency of the approach.
NASA Technical Reports Server (NTRS)
Freeman, Jon C.
2004-01-01
A key parameter in the design trade-offs made during AlGaN/GaN HEMTs development for microwave power amplifiers is the channel temperature. An accurate determination can, in general, only be found using detailed software; however, a quick estimate is always helpful, as it speeds up the design cycle. This paper gives a simple technique to estimate the channel temperature of a generic microwave AlGaN/GaN HEMT on SiC or Sapphire, while incorporating the temperature dependence of the thermal conductivity. The procedure is validated by comparing its predictions with the experimentally measured temperatures in microwave devices presented in three recently published articles. The model predicts the temperature to within 5 to 10 percent of the true average channel temperature. The calculation strategy is extended to determine device temperature in power combining MMICs for solid-state power amplifiers (SSPAs).
Rosas-Cholula, Gerardo; Ramirez-Cortes, Juan Manuel; Alarcon-Aquino, Vicente; Gomez-Gil, Pilar; Rangel-Magdaleno, Jose de Jesus; Reyes-Garcia, Carlos
2013-08-14
This paper presents a project on the development of a cursor control emulating the typical operations of a computer-mouse, using gyroscope and eye-blinking electromyographic signals which are obtained through a commercial 16-electrode wireless headset, recently released by Emotiv. The cursor position is controlled using information from a gyroscope included in the headset. The clicks are generated through the user's blinking with an adequate detection procedure based on the spectral-like technique called Empirical Mode Decomposition (EMD). EMD is proposed as a simple and quick computational tool, yet effective, aimed to artifact reduction from head movements as well as a method to detect blinking signals for mouse control. Kalman filter is used as state estimator for mouse position control and jitter removal. The detection rate obtained in average was 94.9%. Experimental setup and some obtained results are presented.
Rosas-Cholula, Gerardo; Ramirez-Cortes, Juan Manuel; Alarcon-Aquino, Vicente; Gomez-Gil, Pilar; Rangel-Magdaleno, Jose de Jesus; Reyes-Garcia, Carlos
2013-01-01
This paper presents a project on the development of a cursor control emulating the typical operations of a computer-mouse, using gyroscope and eye-blinking electromyographic signals which are obtained through a commercial 16-electrode wireless headset, recently released by Emotiv. The cursor position is controlled using information from a gyroscope included in the headset. The clicks are generated through the user's blinking with an adequate detection procedure based on the spectral-like technique called Empirical Mode Decomposition (EMD). EMD is proposed as a simple and quick computational tool, yet effective, aimed to artifact reduction from head movements as well as a method to detect blinking signals for mouse control. Kalman filter is used as state estimator for mouse position control and jitter removal. The detection rate obtained in average was 94.9%. Experimental setup and some obtained results are presented. PMID:23948873
Efficient design and verification of diagnostics for impurity transport experiments.
Chilenski, M A; Greenwald, M J; Marzouk, Y M; Rice, J E; White, A E
2018-01-01
Recent attempts to measure impurity transport in Alcator C-Mod using an x-ray imaging crystal spectrometer and laser blow-off impurity injector have failed to yield unique reconstructions of the transport coefficient profiles. This paper presents a fast, linearized model which was constructed to estimate diagnostic requirements for impurity transport experiments. The analysis shows that the spectroscopic diagnostics on Alcator C-Mod should be capable of inferring simple profiles of impurity diffusion D Z and convection V Z accurate to better than ±10% uncertainty, suggesting that the failure to infer unique D Z and V Z from experimental data is attributable to an inadequate analysis procedure rather than the result of insufficient diagnostics. Furthermore, the analysis reveals that even a modest spatial resolution can overcome a low time resolution. This approach can be adapted to design and verify diagnostics for transport experiments on any magnetic confinement device.
Fluorescence correlation spectroscopy: the case of subdiffusion.
Lubelski, Ariel; Klafter, Joseph
2009-03-18
The theory of fluorescence correlation spectroscopy is revisited here for the case of subdiffusing molecules. Subdiffusion is assumed to stem from a continuous-time random walk process with a fat-tailed distribution of waiting times and can therefore be formulated in terms of a fractional diffusion equation (FDE). The FDE plays the central role in developing the fluorescence correlation spectroscopy expressions, analogous to the role played by the simple diffusion equation for regular systems. Due to the nonstationary nature of the continuous-time random walk/FDE, some interesting properties emerge that are amenable to experimental verification and may help in discriminating among subdiffusion mechanisms. In particular, the current approach predicts 1), a strong dependence of correlation functions on the initial time (aging); 2), sensitivity of correlation functions to the averaging procedure, ensemble versus time averaging (ergodicity breaking); and 3), that the basic mean-squared displacement observable depends on how the mean is taken.
Phenomenological model for transient deformation based on state variables
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, M S; Cho, C W; Alexopoulos, P
The state variable theory of Hart, while providing a unified description of plasticity-dominated deformation, exhibits deficiencies when it is applied to transient deformation phenomena at stresses below yield. It appears that the description of stored anelastic strain is oversimplified. Consideration of a simple physical picture based on continuum dislocation pileups suggests that the neglect of weak barriers to dislocation motion is the source of these inadequacies. An appropriately modified description incorporating such barriers then allows the construction of a macroscopic model including transient effects. Although the flow relations for the microplastic element required in the new theory are not known,more » tentative assignments may be made for such functions. The model then exhibits qualitatively correct behavior when tensile, loading-unloading, reverse loading, and load relaxation tests are simulated. Experimental procedures are described for determining the unknown parameters and functions in the new model.« less
NASA Technical Reports Server (NTRS)
Chien, C. H.; Swinson, W. F.; Turner, J. L.; Moslehy, F. A.; Ranson, W. F.
1980-01-01
A method for measuring in-plane displacement of a rotating structure by using two laser speckle photographs is described. From the displacement measurements one can calculate strains and stresses due to a centrifugal load. This technique involves making separate speckle photographs of a test model. One photograph is made with the model loaded (model is rotating); the second photograph is made with no load on the model (model is stationary). A sandwich is constructed from the two speckle photographs and data are recovered in a manner similar to that used with conventional speckle photography. The basic theory, experimental procedures of this method, and data analysis of a simple rotating specimen are described. In addition the measurement of in-plane surface displacement components of a deformed solid, and the application of the coupled laser speckle interferometry and boundary-integral solution technique to two dimensional elasticity problems are addressed.
Fu, Xiaotong; Mavrogiannis, Nicholas; Ibo, Markela; Crivellari, Francesca; Gagnon, Zachary R
2017-01-01
We present a new type of free-flow electrophoresis (FFE) device for performing on-chip microfluidic isotachophoresis and zone electrophoresis. FFE is performed using metal gallium electrodes, which are isolated from a main microfluidic flow channel using thin micron-scale polydimethylsiloxane/carbon black (PDMS/CB) composite membranes integrated directly into the sidewalls of the microfluidic channel. The thin membrane allows for field penetration and effective electrophoresis, but serves to prevent bubble generation at the electrodes from electrolysis. We experimentally demonstrate the ability to use this platform to perform on-chip free-flow electrophoretic separation and isotachophoretic concentration. Due to the small size and simple fabrication procedure, this PDMS/CB platform could be used as a part of an on-chip upstream sample preparation toolkit for portable microfluidic diagnostic applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ion specific correlations in bulk and at biointerfaces.
Kalcher, I; Horinek, D; Netz, R R; Dzubiella, J
2009-10-21
Ion specific effects are ubiquitous in any complex colloidal or biological fluid in bulk or at interfaces. The molecular origins of these 'Hofmeister effects' are not well understood and their theoretical description poses a formidable challenge to the modeling and simulation community. On the basis of the combination of atomistically resolved molecular dynamics (MD) computer simulations and statistical mechanics approaches, we present a few selected examples of specific electrolyte effects in bulk, at simple neutral and charged interfaces, and on a short α-helical peptide. The structural complexity in these strongly Coulomb-correlated systems is highlighted and analyzed in the light of available experimental data. While in general the comparison of MD simulations to experiments often lacks quantitative agreement, mostly because molecular force fields and coarse-graining procedures remain to be optimized, the consensus as regards trends provides important insights into microscopic hydration and binding mechanisms.
Passively mode-locked soliton femtosecond pulses employing graphene saturable absorber
NASA Astrophysics Data System (ADS)
Lau, K. Y.; Muhammad, F. D.; Latif, A. A.; Abu Bakar, M. H.; Yusoff, Z.; Mahdi, M. A.
2017-09-01
We demonstrate a passively mode-locked fiber laser incorporating graphene thin film (GTF) as saturable absorber (SA). The SA is fabricated by sandwiching the GTF between two single mode fiber ferrules through a fiber adaptor. The transmission loss at 1560 nm and non-linear saturation absorption modulation depth for GTF-SA are 0.8 dB and 2.90%, respectively. An erbium-doped fiber laser cavity is constructed to verify the functionality of GTF-SA and is designed to have net anomalous dispersion. It generates large spectral width of 4.99 nm with pulse repetition rate of 9.655 MHz and pulse width of 670 fs. Net anomalous dispersion and time bandwidth product higher than the sech2 transform-limited pulse validate the experimental result. In short, we demonstrate high performance GTF-SA that is able to generate ultrafast pulse duration in femtosecond range effortlessly with simple and green SA fabrication procedures.
Investigation of piezoelectric impedance-based health monitoring of structure interface debonding
NASA Astrophysics Data System (ADS)
Xiao, Li; Chen, Guofeng; Chen, Xiaoming; Qu, Wenzhong
2016-04-01
Various damages might occur during the solid rocket motor (SRM) manufacturing/operational phase, and the debonding of propellant/insulator/composite case interfaces is one of damage types which determine the life of a motor. The detection of such interface debonding damage will be beneficial for developing techniques for reliable nondestructive evaluation (NDE) and structural health monitoring (SHM). Piezoelectric sensors are widely used for structural health monitoring technique. In particular, electromechanical impedance (EMI) techniques give simple and low-cost solutions for detecting damage in various structures. In this work, piezoelectric EMI structural health monitoring technique is applied to identify the debonding condition of propellant/insulator interface structure using finite element method and experimental investigation. A three-dimensional coupled field finite element model is developed using the software ANSYS and the harmonic analysis is conducted for high-frequency impedance analysis procedure. In the experimental study, the impedance signals were measured from PZT and MFC sensors outside attached to composite case monitoring the different debonding conditions between the propellant and insulator. Root mean square deviation (RMSD) based damage index is conducted to quantify the changes i n impedance for different de bonding conditions and frequency range. Simulation and experimental results confirmed that the EMI technique can be used effectively for detecting the debonding damage in SRM and is expected to be useful for future application of real SRM's SHM.
Lin, Che-Hsin; Lee, Gwo-Bin; Fu, Lung-Ming; Chen, Shu-Hui
2004-07-30
This paper presents a novel micro-capillary electrophoresis (CE) chip with embedded optical fibers for the on-line detection of DNA samples. The optical fibers are pre-etched and then inserted directly into fiber channels incorporated within low-cost soda-lime glass substrates. The embedded optical fibers are precisely aligned with the microfluidic channels such that the induced fluorescence signals from labeled bio-samples can be detected. This arrangement avoids the requirement for delicate optical alignment procedures and equipment. Surface modification of the CE channels is accomplished by means of a simple and reliable organic-based spin-on-glass (SOG) method. The zeta potential distribution and the corresponding electroosmotic mobility of the fluid are simulated numerically for the modified and non-modified channel surfaces, and then both sets of results are verified experimentally. The present results indicate that the value of the zeta potential for a surface with an SOG coating is 19.3 times smaller than that of an untreated surface. A phiX-174 DNA marker fluid is used to evaluate the injection and separation performance of the developed micro-CE device. Furthermore, the long-term stability of the SOG-coated surface is also investigated. The experimental data reveal that the microchip device is capable of providing highly efficient separations of bio-molecules, and that the SOG layer retains its low zeta potential characteristics for at least 45 days. The present results confirm the effectiveness of the proposed micro-CE chip in performing the on-line detection of DNA samples, and indicate that the SOG process represents a simple and reliable solution for the surface modification of glass-based microchannels.
Ranking Cognitive Flexibility in a Group Setting of Rhesus Monkeys with a Set-Shifting Procedure.
Shnitko, Tatiana A; Allen, Daicia C; Gonzales, Steven W; Walter, Nicole A R; Grant, Kathleen A
2017-01-01
Attentional set-shifting ability is an executive function underling cognitive flexibility in humans and animals. In humans, this function is typically observed during a single experimental session where dimensions of playing cards are used to measure flexibility in the face of changing rules for reinforcement (i.e., the Wisconsin Card Sorting Test (WCST)). In laboratory animals, particularly non-human primates, variants of the WCST involve extensive training and testing on a series of dimensional discriminations, usually in social isolation. In the present study, a novel experimental approach was used to assess attentional set-shifting simultaneously in 12 rhesus monkeys. Specifically, monkeys living in individual cages but in the same room were trained at the same time each day in a set-shifting task in the same housing environment. As opposed to the previous studies, each daily session began with a simple single-dimension discrimination regardless of the animal's performance on the previous session. A total of eight increasingly difficult, discriminations (sets) were possible in each daily 45 min session. Correct responses were reinforced under a second-order schedule of flavored food pellet delivery, and criteria for completing a set was 12 correct trials out of a running total of 15 trials. Monkeys progressed through the sets at their own pace and abilities. The results demonstrate that all 12 monkeys acquired the simple discrimination (the first set), but individual differences in the ability to progress through all eight sets were apparent. A performance index (PI) that encompassed progression through the sets, errors and session duration was calculated and used to rank each monkey's performance in relation to each other. Overall, this version of a set-shifting task results in an efficient assessment of reliable differences in cognitive flexibility in a group of monkeys.
Ranking Cognitive Flexibility in a Group Setting of Rhesus Monkeys with a Set-Shifting Procedure
Shnitko, Tatiana A.; Allen, Daicia C.; Gonzales, Steven W.; Walter, Nicole A. R.; Grant, Kathleen A.
2017-01-01
Attentional set-shifting ability is an executive function underling cognitive flexibility in humans and animals. In humans, this function is typically observed during a single experimental session where dimensions of playing cards are used to measure flexibility in the face of changing rules for reinforcement (i.e., the Wisconsin Card Sorting Test (WCST)). In laboratory animals, particularly non-human primates, variants of the WCST involve extensive training and testing on a series of dimensional discriminations, usually in social isolation. In the present study, a novel experimental approach was used to assess attentional set-shifting simultaneously in 12 rhesus monkeys. Specifically, monkeys living in individual cages but in the same room were trained at the same time each day in a set-shifting task in the same housing environment. As opposed to the previous studies, each daily session began with a simple single-dimension discrimination regardless of the animal’s performance on the previous session. A total of eight increasingly difficult, discriminations (sets) were possible in each daily 45 min session. Correct responses were reinforced under a second-order schedule of flavored food pellet delivery, and criteria for completing a set was 12 correct trials out of a running total of 15 trials. Monkeys progressed through the sets at their own pace and abilities. The results demonstrate that all 12 monkeys acquired the simple discrimination (the first set), but individual differences in the ability to progress through all eight sets were apparent. A performance index (PI) that encompassed progression through the sets, errors and session duration was calculated and used to rank each monkey’s performance in relation to each other. Overall, this version of a set-shifting task results in an efficient assessment of reliable differences in cognitive flexibility in a group of monkeys. PMID:28386222
Nonlinear and threshold-dominated runoff generation controls DOC export in a small peat catchment
NASA Astrophysics Data System (ADS)
Birkel, C.; Broder, T.; Biester, H.
2017-03-01
We used a relatively simple two-layer, coupled hydrology-biogeochemistry model to simultaneously simulate streamflow and stream dissolved organic carbon (DOC) concentrations in a small lead and arsenic contaminated upland peat catchment in northwestern Germany. The model procedure was informed by an initial data mining analysis, in combination with regression relationships of discharge, DOC, and element export. We assessed the internal model DOC processing based on stream DOC hysteresis patterns and 3-hourly time step groundwater level and soil DOC data for two consecutive summer periods in 2013 and 2014. The parsimonious model (i.e., few calibrated parameters) showed the importance of nonlinear and rapid near-surface runoff generation mechanisms that caused around 60% of simulated DOC load. The total load was high even though these pathways were only activated during storm events on average 30% of the monitoring time—as also shown by the experimental data. Overall, the drier period 2013 resulted in increased nonlinearity but exported less DOC (115 kg C ha-1 yr-1 ± 11 kg C ha-1 yr-1) compared to the equivalent but wetter period in 2014 (189 kg C ha-1 yr-1 ± 38 kg C ha-1 yr-1). The exceedance of a critical water table threshold (-10 cm) triggered a rapid near-surface runoff response with associated higher DOC transport connecting all available DOC pools and subsequent dilution. We conclude that the combination of detailed experimental work with relatively simple, coupled hydrology-biogeochemistry models not only allowed the model to be internally constrained but also provided important insight into how DOC and tightly coupled pollutants or trace elements are mobilized.
Richards, V. M.; Dai, W.
2014-01-01
A MATLAB toolbox for the efficient estimation of the threshold, slope, and lapse rate of the psychometric function is described. The toolbox enables the efficient implementation of the updated maximum-likelihood (UML) procedure. The toolbox uses an object-oriented architecture for organizing the experimental variables and computational algorithms, which provides experimenters with flexibility in experimental design and data management. Descriptions of the UML procedure and the UML Toolbox are provided, followed by toolbox use examples. Finally, guidelines and recommendations of parameter configurations are given. PMID:24671826
NASA Technical Reports Server (NTRS)
Byrne, K. P.; Marshall, S. E.
1983-01-01
A procedure for experimentally determining, in terms of the particle motions, the shapes of the low order acoustic modes in enclosures is described. The procedure is based on finding differentiable functions which approximate the shape functions of the low order acoustic modes when these modes are defined in terms of the acoustic pressure. The differentiable approximating functions are formed from polynomials which are fitted by a least squares procedure to experimentally determined values which define the shapes of the low order acoustic modes in terms of the acoustic pressure. These experimentally determined values are found by a conventional technique in which the transfer functions, which relate the acoustic pressures at an array of points in the enclosure to the volume velocity of a fixed point source, are measured. The gradient of the function which approximates the shape of a particular mode in terms of the acoustic pressure is evaluated to give the mode shape in terms of the particle motion. The procedure was tested by using it to experimentally determine the shapes of the low order acoustic modes in a small rectangular enclosure.
A-Priori Tuning of Modified Magnussen Combustion Model
NASA Technical Reports Server (NTRS)
Norris, A. T.
2016-01-01
In the application of CFD to turbulent reacting flows, one of the main limitations to predictive accuracy is the chemistry model. Using a full or skeletal kinetics model may provide good predictive ability, however, at considerable computational cost. Adding the ability to account for the interaction between turbulence and chemistry improves the overall fidelity of a simulation but adds to this cost. An alternative is the use of simple models, such as the Magnussen model, which has negligible computational overhead, but lacks general predictive ability except for cases that can be tuned to the flow being solved. In this paper, a technique will be described that allows the tuning of the Magnussen model for an arbitrary fuel and flow geometry without the need to have experimental data for that particular case. The tuning is based on comparing the results of the Magnussen model and full finite-rate chemistry when applied to perfectly and partially stirred reactor simulations. In addition, a modification to the Magnussen model is proposed that allows the upper kinetic limit for the reaction rate to be set, giving better physical agreement with full kinetic mechanisms. This procedure allows a simple reacting model to be used in a predictive manner, and affords significant savings in computational costs for simulations.
Aggregative Learning Method and Its Application for Communication Quality Evaluation
NASA Astrophysics Data System (ADS)
Akhmetov, Dauren F.; Kotaki, Minoru
2007-12-01
In this paper, so-called Aggregative Learning Method (ALM) is proposed to improve and simplify the learning and classification abilities of different data processing systems. It provides a universal basis for design and analysis of mathematical models of wide class. A procedure was elaborated for time series model reconstruction and analysis for linear and nonlinear cases. Data approximation accuracy (during learning phase) and data classification quality (during recall phase) are estimated from introduced statistic parameters. The validity and efficiency of the proposed approach have been demonstrated through its application for monitoring of wireless communication quality, namely, for Fixed Wireless Access (FWA) system. Low memory and computation resources were shown to be needed for the procedure realization, especially for data classification (recall) stage. Characterized with high computational efficiency and simple decision making procedure, the derived approaches can be useful for simple and reliable real-time surveillance and control system design.
Detection of Cherenkov Photons with Multi-Anode Photomultipliers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salazar, H.; Moreno, E.; Murrieta, T.
2006-09-25
The present paper describes the laboratory course given at the X Mexican Workshop on Particles and Fields. We describe the setup and procedure used to measure the Cherenkov circles produced by cosmic muons upon traversal of a simple glass radiator system. The main purpose of this exercise is to introduce the students to work with multi-anode photomultipliers such as the one used for this experiment (Hamamatsu R5900-M64), with which measurements requiring position sensitive detection of single photons can be successfully performed. We present a short introduction to multi-anode photomultipliers (MAPMT) and describe the setup and the procedure used to measuremore » the response of a MAPMT to a uniform source of light. Finally, we describe the setup and procedure used to measure the Cherenkov circles produced by cosmic muons upon traversal of a simple glass radiator system.« less
NASA Astrophysics Data System (ADS)
Kalachev, L. V.
2016-06-01
We present a simple model of experimental setup for in vitro study of drug release from drug eluting stents and drug propagation in artificial tissue samples representing blood vessels. The model is further reduced using the assumption on vastly different characteristic diffusion times in the stent coating and in the artificial tissue. The model is used to derive a relationship between the times at which the measurements have to be taken for two experimental platforms, with corresponding artificial tissue samples made of different materials with different drug diffusion coefficients, to properly compare the drug release characteristics of drug eluting stents.
Bell's Theorem and Einstein's "Spooky Actions" from a Simple Thought Experiment
ERIC Educational Resources Information Center
Kuttner, Fred; Rosenblum, Bruce
2010-01-01
In 1964 John Bell proved a theorem allowing the experimental test of whether what Einstein derided as "spooky actions at a distance" actually exist. We will see that they "do". Bell's theorem can be displayed with a simple, nonmathematical thought experiment suitable for a physics course at "any" level. And a simple, semi-classical derivation of…