Simple, Fast, and Sensitive Method for Quantification of Tellurite in Culture Media▿
Molina, Roberto C.; Burra, Radhika; Pérez-Donoso, José M.; Elías, Alex O.; Muñoz, Claudia; Montes, Rebecca A.; Chasteen, Thomas G.; Vásquez, Claudio C.
2010-01-01
A fast, simple, and reliable chemical method for tellurite quantification is described. The procedure is based on the NaBH4-mediated reduction of TeO32− followed by the spectrophotometric determination of elemental tellurium in solution. The method is highly reproducible, is stable at different pH values, and exhibits linearity over a broad range of tellurite concentrations. PMID:20525868
Newly developed double neural network concept for reliable fast plasma position control
NASA Astrophysics Data System (ADS)
Jeon, Young-Mu; Na, Yong-Su; Kim, Myung-Rak; Hwang, Y. S.
2001-01-01
Neural network is considered as a parameter estimation tool in plasma controls for next generation tokamak such as ITER. The neural network has been reported to be so accurate and fast for plasma equilibrium identification that it may be applied to the control of complex tokamak plasmas. For this application, the reliability of the conventional neural network needs to be improved. In this study, a new idea of double neural network is developed to achieve this. The new idea has been applied to simple plasma position identification of KSTAR tokamak for feasibility test. Characteristics of the concept show higher reliability and fault tolerance even in severe faulty conditions, which may make neural network applicable to plasma control reliably and widely in future tokamaks.
Rakesh Minocha; Walter C. Shortle
1993-01-01
Two simple and fast methods for the extraction of major inorganic cations (Ca, Mg, Mn, K) from small quantities of stemwood and needles of woody plants were developed. A 3.2- or 6.4-mm cobalt drill bit was used to shave samples from disks and increment cores of stemwood. For ion extraction, wood (ground or shavings) or needles were either homogenzied using a Tekmar...
Generalised Category Attack—Improving Histogram-Based Attack on JPEG LSB Embedding
NASA Astrophysics Data System (ADS)
Lee, Kwangsoo; Westfeld, Andreas; Lee, Sangjin
We present a generalised and improved version of the category attack on LSB steganography in JPEG images with straddled embedding path. It detects more reliably low embedding rates and is also less disturbed by double compressed images. The proposed methods are evaluated on several thousand images. The results are compared to both recent blind and specific attacks for JPEG embedding. The proposed attack permits a more reliable detection, although it is based on first order statistics only. Its simple structure makes it very fast.
Yang, Heejung; Kim, Hyun Woo; Kwon, Yong Soo; Kim, Ho Kyong; Sung, Sang Hyun
2017-09-01
Anthocyanins are potent antioxidant agents that protect against many degenerative diseases; however, they are unstable because they are vulnerable to external stimuli including temperature, pH and light. This vulnerability hinders the quality control of anthocyanin-containing berries using classical high-performance liquid chromatography (HPLC) analytical methodologies based on UV or MS chromatograms. To develop an alternative approach for the quality assessment and discrimination of anthocyanin-containing berries, we used MS spectral data acquired in a short analytical time rather than UV or MS chromatograms. Mixtures of anthocyanins were separated from other components in a short gradient time (5 min) due to their higher polarity, and the representative MS spectrum was acquired from the MS chromatogram corresponding to the mixture of anthocyanins. The chemometric data from the representative MS spectra contained reliable information for the identification and relative quantification of anthocyanins in berries with good precision and accuracy. This fast and simple methodology, which consists of a simple sample preparation method and short gradient analysis, could be applied to reliably discriminate the species and geographical origins of different anthocyanin-containing berries. These features make the technique useful for the food industry. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Dalverny, Anne-Laure; Leyral, Géraldine; Rouessac, Florence; Bernaud, Laurent; Filhol, Jean-Sébastien
2018-01-01
Magnetic iron oxide nanoparticles were synthesized and stabilized using ammonium cations or poly(vinyl alcohol) to produce amazing materials such as safer aqueous ferrofluids, ferrogels, ferromagnetic inks, plastics, and nanopowders illustrating how versatile materials can be produced just by simple modifications. The synthesis is fast, reliable,…
USDA-ARS?s Scientific Manuscript database
Microwave digestion followed by analysis using ICP-MS has been shown to be a simple, fast reliable method for the multi-element determination in multivitamin/mineral dietary supplements (MVM). A study of 35 popular MVM dietary supplements revealed that composition and levels varied among products, a...
USDA-ARS?s Scientific Manuscript database
Foodborne diseases are of serious concern for public health. It is necessary to develop fast and reliable non-destructive detection methods to improve food product monitoring for the food industry. This research was conducted to investigate hyperspectral fluorescence imaging using violet/blue LED ex...
Meyer, Golo M J; Weber, Armin A; Maurer, Hans H
2014-05-01
Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1 h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples. Copyright © 2013 John Wiley & Sons, Ltd.
Brain State Effects on Layer 4 of the Awake Visual Cortex
Zhuang, Jun; Bereshpolova, Yulia; Stoelzel, Carl R.; Huff, Joseph M.; Hei, Xiaojuan; Alonso, Jose-Manuel
2014-01-01
Awake mammals can switch between alert and nonalert brain states hundreds of times per day. Here, we study the effects of alertness on two cell classes in layer 4 of primary visual cortex of awake rabbits: presumptive excitatory “simple” cells and presumptive fast-spike inhibitory neurons (suspected inhibitory interneurons). We show that in both cell classes, alertness increases the strength and greatly enhances the reliability of visual responses. In simple cells, alertness also increases the temporal frequency bandwidth, but preserves contrast sensitivity, orientation tuning, and selectivity for direction and spatial frequency. Finally, alertness selectively suppresses the simple cell responses to high-contrast stimuli and stimuli moving orthogonal to the preferred direction, effectively enhancing mid-contrast borders. Using a population coding model, we show that these effects of alertness in simple cells—enhanced reliability, higher gain, and increased suppression in orthogonal orientation—could play a major role at increasing the speed of cortical feature detection. PMID:24623767
Kremkow, Jens; Perrinet, Laurent U.; Monier, Cyril; Alonso, Jose-Manuel; Aertsen, Ad; Frégnac, Yves; Masson, Guillaume S.
2016-01-01
Neurons in the primary visual cortex are known for responding vigorously but with high variability to classical stimuli such as drifting bars or gratings. By contrast, natural scenes are encoded more efficiently by sparse and temporal precise spiking responses. We used a conductance-based model of the visual system in higher mammals to investigate how two specific features of the thalamo-cortical pathway, namely push-pull receptive field organization and fast synaptic depression, can contribute to this contextual reshaping of V1 responses. By comparing cortical dynamics evoked respectively by natural vs. artificial stimuli in a comprehensive parametric space analysis, we demonstrate that the reliability and sparseness of the spiking responses during natural vision is not a mere consequence of the increased bandwidth in the sensory input spectrum. Rather, it results from the combined impacts of fast synaptic depression and push-pull inhibition, the later acting for natural scenes as a form of “effective” feed-forward inhibition as demonstrated in other sensory systems. Thus, the combination of feedforward-like inhibition with fast thalamo-cortical synaptic depression by simple cells receiving a direct structured input from thalamus composes a generic computational mechanism for generating a sparse and reliable encoding of natural sensory events. PMID:27242445
An Energy-Based Limit State Function for Estimation of Structural Reliability in Shock Environments
Guthrie, Michael A.
2013-01-01
limit state function is developed for the estimation of structural reliability in shock environments. This limit state function uses peak modal strain energies to characterize environmental severity and modal strain energies at failure to characterize the structural capacity. The Hasofer-Lind reliability index is briefly reviewed and its computation for the energy-based limit state function is discussed. Applications to two degree of freedom mass-spring systems and to a simple finite element model are considered. For these examples, computation of the reliability index requires little effort beyond a modal analysis, but still accounts for relevant uncertainties in both the structure and environment.more » For both examples, the reliability index is observed to agree well with the results of Monte Carlo analysis. In situations where fast, qualitative comparison of several candidate designs is required, the reliability index based on the proposed limit state function provides an attractive metric which can be used to compare and control reliability.« less
On Algorithms for Generating Computationally Simple Piecewise Linear Classifiers
1989-05-01
suffers. - Waveform classification, e.g. speech recognition, seismic analysis (i.e. discrimination between earthquakes and nuclear explosions), target...assuming Gaussian distributions (B-G) d) Bayes classifier with probability densities estimated with the k-N-N method (B- kNN ) e) The -arest neighbour...range of classifiers are chosen including a fast, easy computable and often used classifier (B-G), reliable and complex classifiers (B- kNN and NNR
[Differentiation of geographic biovariants of smallpox virus by PCR].
Babkin, I V; Babkina, I N
2010-01-01
Comparative analysis of amino acid and nucleotides sequences of ORFs located in extended segments of the terminal variable regions in variola virus genome detected a promising locus for viral genotyping according to the geographic origin. This is ORF O1L of VARV. The primers were calculated for synthesis of this ORF fragment by PCR, which makes it possible to distinguish South America-Western Africa genotype from other VARV strains. Subsequent RFLP analysis reliably differentiated Asian strains from African strains (except Western Africa isolates). This method has been tested using 16 VARV strains from various geographic regions. The developed approach is simple, fast and reliable.
Evaluation and application of a fast module in a PLC based interlock and control system
NASA Astrophysics Data System (ADS)
Zaera-Sanz, M.
2009-08-01
The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of μseconds. Siemens has introduced a ``so called'' fast module (FM352-5 Boolean Processor). It provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This paper publishes the results of this study. As well, this paper could be useful for other applications requiring fast processing using a PLC.
Fast response pyroelectric detector-preamplifier assembled device
NASA Astrophysics Data System (ADS)
Bai, PiJi; Tai, Yunjian; Liu, Huiping
2008-03-01
The pyroelectric detector is wide used for its simple structure and high performance to price ratio. It has been used in thermal detecting, infrared spectrum and laser testing. When the pyroelectric detector was applied in practice, fast reponse speed is need. For improving the response speed of the pyroelectric detector some specific technology has been used in the preamplifier schematic. High sense and fast response character of the pyroelectric detector-preamplifier assembled device had been achieved. When the device is applied in acute concussion condition, it must survive from the acute concussion condition testing. For it reliability some specific technology was used in the device fabricating procedure. At last the performance parameter testing result and simulation application condition result given in this paper show the performance of the pyroelectric detector-preamplifier assembled device had achieved the advance goal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josephson, J.; Sowa, E.S.
1977-04-01
The design and testing of a simple and reliable Self-Actuated Shutdown System (SASS) for the protection of Liquid Metal Fast Breeder Reactors (LMFBRs) is described. A ferromagnetic Curie temperature permanent magnet holding device has been selected for the design of the Self-Actuated Shutdown System in order to enhance the safety of liquid metal cooled fast reactors (LMFBRs). The self-actuated, self-contained device operates such that accident conditions, resulting in increased coolant temperature or neutron flux reduce the magnetic holding force suspending a neutron absorber above the core by raising the temperature of the trigger mechanism above the Curie point. Neutron absorbermore » material is then inserted into the core, under gravity, terminating the accident. Two possible design variations of the selected concept are presented.« less
[Evaluation of mass spectrometry: MALDI-TOF MS for fast and reliable yeast identification].
Relloso, María S; Nievas, Jimena; Fares Taie, Santiago; Farquharson, Victoria; Mujica, María T; Romano, Vanesa; Zarate, Mariela S; Smayevsky, Jorgelina
2015-01-01
The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique known as MALDI-TOF MS is a tool used for the identification of clinical pathogens by generating a protein spectrum that is unique for a given species. In this study we assessed the identification of clinical yeast isolates by MALDI-TOF MS in a university hospital from Argentina and compared two procedures for protein extraction: a rapid method and a procedure based on the manufacturer's recommendations. A short protein extraction procedure was applied in 100 isolates and the rate of correct identification at genus and species level was 98.0%. In addition, we analyzed 201 isolates, previously identified by conventional methods, using the methodology recommended by the manufacturer and there was 95.38% coincidence in the identification at species level. MALDI TOF MS showed to be a fast, simple and reliable tool for yeast identification. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Fast and Reliable Thermodynamic Approach for Determining the Protonation State of the Asp Dyad.
Huang, Jinfeng; Sun, Bin; Yao, Yuan; Liu, Junjun
2017-09-25
The protonation state of the asp dyad is significantly important in revealing enzymatic mechanisms and developing drugs. However, it is hard to determine by calculating free energy changes between possible protonation states, because the free energy changes due to protein conformational flexibility are usually much larger than those originating from different locations of protons. Sophisticated and computationally expensive methods such as free energy perturbation, thermodynamic integration (TI), and quantum mechanics/molecular mechanics are therefore usually used for this purpose. In the present study, we have developed a simple thermodynamic approach to effectively eliminating the free energy changes arising from protein conformational flexibility and estimating the free energy changes only originated from the locations of protons, which provides a fast and reliable method for determining the protonation state of asp dyads. The test of this approach on a total of 15 asp dyad systems, including BACE-1 and HIV-1 protease, shows that the predictions from this approach are all consistent with experiments or with the computationally expensive TI calculations. It is clear that our thermodynamic approach could be used to rapidly and reliably determine the protonation state of the asp dyad.
Normative Data for an Instrumental Assessment of the Upper-Limb Functionality.
Caimmi, Marco; Guanziroli, Eleonora; Malosio, Matteo; Pedrocchi, Nicola; Vicentini, Federico; Molinari Tosatti, Lorenzo; Molteni, Franco
2015-01-01
Upper-limb movement analysis is important to monitor objectively rehabilitation interventions, contributing to improving the overall treatments outcomes. Simple, fast, easy-to-use, and applicable methods are required to allow routinely functional evaluation of patients with different pathologies and clinical conditions. This paper describes the Reaching and Hand-to-Mouth Evaluation Method, a fast procedure to assess the upper-limb motor control and functional ability, providing a set of normative data from 42 healthy subjects of different ages, evaluated for both the dominant and the nondominant limb motor performance. Sixteen of them were reevaluated after two weeks to perform test-retest reliability analysis. Data were clustered into three subgroups of different ages to test the method sensitivity to motor control differences. Experimental data show notable test-retest reliability in all tasks. Data from older and younger subjects show significant differences in the measures related to the ability for coordination thus showing the high sensitivity of the method to motor control differences. The presented method, provided with control data from healthy subjects, appears to be a suitable and reliable tool for the upper-limb functional assessment in the clinical environment.
Normative Data for an Instrumental Assessment of the Upper-Limb Functionality
Caimmi, Marco; Guanziroli, Eleonora; Malosio, Matteo; Pedrocchi, Nicola; Vicentini, Federico; Molinari Tosatti, Lorenzo; Molteni, Franco
2015-01-01
Upper-limb movement analysis is important to monitor objectively rehabilitation interventions, contributing to improving the overall treatments outcomes. Simple, fast, easy-to-use, and applicable methods are required to allow routinely functional evaluation of patients with different pathologies and clinical conditions. This paper describes the Reaching and Hand-to-Mouth Evaluation Method, a fast procedure to assess the upper-limb motor control and functional ability, providing a set of normative data from 42 healthy subjects of different ages, evaluated for both the dominant and the nondominant limb motor performance. Sixteen of them were reevaluated after two weeks to perform test-retest reliability analysis. Data were clustered into three subgroups of different ages to test the method sensitivity to motor control differences. Experimental data show notable test-retest reliability in all tasks. Data from older and younger subjects show significant differences in the measures related to the ability for coordination thus showing the high sensitivity of the method to motor control differences. The presented method, provided with control data from healthy subjects, appears to be a suitable and reliable tool for the upper-limb functional assessment in the clinical environment. PMID:26539500
Delatorre, Carolina; Rodríguez, Ana; Rodríguez, Lucía; Majada, Juan P; Ordás, Ricardo J; Feito, Isabel
2017-01-01
Plant growth regulators (PGRs) are very different chemical compounds that play essential roles in plant development and the regulation of physiological processes. They exert their functions by a mechanism called cross-talk (involving either synergistic or antagonistic actions) thus; it is for great interest to study as many PGRs as possible to obtain accurate information about plant status. Much effort has been applied to develop methods capable of analyze large numbers of these compounds but frequently excluding some chemical families or important PGRs within each family. In addition, most of the methods are specially designed for matrices easy to work with. Therefore, we wanted to develop a method which achieved the requirements lacking in the literature and also being fast and reliable. Here we present a simple, fast and robust method for the extraction and quantification of 20 different PGRs using UHPLC-MS/MS optimized in complex matrices. Copyright © 2016 Elsevier B.V. All rights reserved.
Aknoun, Sherazade; Savatier, Julien; Bon, Pierre; Galland, Frédéric; Abdeladim, Lamiae; Wattellier, Benoit; Monneret, Serge
2015-01-01
Single-cell dry mass measurement is used in biology to follow cell cycle, to address effects of drugs, or to investigate cell metabolism. Quantitative phase imaging technique with quadriwave lateral shearing interferometry (QWLSI) allows measuring cell dry mass. The technique is very simple to set up, as it is integrated in a camera-like instrument. It simply plugs onto a standard microscope and uses a white light illumination source. Its working principle is first explained, from image acquisition to automated segmentation algorithm and dry mass quantification. Metrology of the whole process, including its sensitivity, repeatability, reliability, sources of error, over different kinds of samples and under different experimental conditions, is developed. We show that there is no influence of magnification or spatial light coherence on dry mass measurement; effect of defocus is more critical but can be calibrated. As a consequence, QWLSI is a well-suited technique for fast, simple, and reliable cell dry mass study, especially for live cells.
Zhao, Henry; Pesavento, Lauren; Coote, Skye; Rodrigues, Edrich; Salvaris, Patrick; Smith, Karen; Bernard, Stephen; Stephenson, Michael; Churilov, Leonid; Yassi, Nawaf; Davis, Stephen M; Campbell, Bruce C V
2018-04-01
Clinical triage scales for prehospital recognition of large vessel occlusion (LVO) are limited by low specificity when applied by paramedics. We created the 3-step ambulance clinical triage for acute stroke treatment (ACT-FAST) as the first algorithmic LVO identification tool, designed to improve specificity by recognizing only severe clinical syndromes and optimizing paramedic usability and reliability. The ACT-FAST algorithm consists of (1) unilateral arm drift to stretcher <10 seconds, (2) severe language deficit (if right arm is weak) or gaze deviation/hemineglect assessed by simple shoulder tap test (if left arm is weak), and (3) eligibility and stroke mimic screen. ACT-FAST examination steps were retrospectively validated, and then prospectively validated by paramedics transporting culturally and linguistically diverse patients with suspected stroke in the emergency department, for the identification of internal carotid or proximal middle cerebral artery occlusion. The diagnostic performance of the full ACT-FAST algorithm was then validated for patients accepted for thrombectomy. In retrospective (n=565) and prospective paramedic (n=104) validation, ACT-FAST displayed higher overall accuracy and specificity, when compared with existing LVO triage scales. Agreement of ACT-FAST between paramedics and doctors was excellent (κ=0.91; 95% confidence interval, 0.79-1.0). The full ACT-FAST algorithm (n=60) assessed by paramedics showed high overall accuracy (91.7%), sensitivity (85.7%), specificity (93.5%), and positive predictive value (80%) for recognition of endovascular-eligible LVO. The 3-step ACT-FAST algorithm shows higher specificity and reliability than existing scales for clinical LVO recognition, despite requiring just 2 examination steps. The inclusion of an eligibility step allowed recognition of endovascular-eligible patients with high accuracy. Using a sequential algorithmic approach eliminates scoring confusion and reduces assessment time. Future studies will test whether field application of ACT-FAST by paramedics to bypass suspected patients with LVO directly to endovascular-capable centers can reduce delays to endovascular thrombectomy. © 2018 American Heart Association, Inc.
Fetal acoustic stimulation test for early intrapartum fetal monitoring.
Goonewardene, M; Hanwellage, K
2011-03-01
The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p < 0.001), specificity (100% vs 87%, p = 0.017), positive predictive value (100% vs 98%, p = 0.024), negative predictive value (79% vs 17%, p < 0.001) and accuracy (99%vs 64%, p < 0.001) in predicting 5 minute APGAR < 7 in the baby. FAST is a reliable screening test for assessing fetal well being in early labour. It complements the NST and is better than the NST alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bucknor, Matthew; Grabaskas, David; Brunett, Acacia
2015-04-26
Advanced small modular reactor designs include many advantageous design features such as passively driven safety systems that are arguably more reliable and cost effective relative to conventional active systems. Despite their attractiveness, a reliability assessment of passive systems can be difficult using conventional reliability methods due to the nature of passive systems. Simple deviations in boundary conditions can induce functional failures in a passive system, and intermediate or unexpected operating modes can also occur. As part of an ongoing project, Argonne National Laboratory is investigating various methodologies to address passive system reliability. The Reliability Method for Passive Systems (RMPS), amore » systematic approach for examining reliability, is one technique chosen for this analysis. This methodology is combined with the Risk-Informed Safety Margin Characterization (RISMC) approach to assess the reliability of a passive system and the impact of its associated uncertainties. For this demonstration problem, an integrated plant model of an advanced small modular pool-type sodium fast reactor with a passive reactor cavity cooling system is subjected to a station blackout using RELAP5-3D. This paper discusses important aspects of the reliability assessment, including deployment of the methodology, the uncertainty identification and quantification process, and identification of key risk metrics.« less
Integrated protocol for reliable and fast quantification and documentation of electrophoresis gels.
Rehbein, Peter; Schwalbe, Harald
2015-06-01
Quantitative analysis of electrophoresis gels is an important part in molecular cloning, as well as in protein expression and purification. Parallel quantifications in yield and purity can be most conveniently obtained from densitometric analysis. This communication reports a comprehensive, reliable and simple protocol for gel quantification and documentation, applicable for single samples and with special features for protein expression screens. As major component of the protocol, the fully annotated code of a proprietary open source computer program for semi-automatic densitometric quantification of digitized electrophoresis gels is disclosed. The program ("GelQuant") is implemented for the C-based macro-language of the widespread integrated development environment of IGOR Pro. Copyright © 2014 Elsevier Inc. All rights reserved.
Haider, Bilal; Krause, Matthew R.; Duque, Alvaro; Yu, Yuguo; Touryan, Jonathan; Mazer, James A.; McCormick, David A.
2011-01-01
SUMMARY During natural vision, the entire visual field is stimulated by images rich in spatiotemporal structure. Although many visual system studies restrict stimuli to the classical receptive field (CRF), it is known that costimulation of the CRF and the surrounding nonclassical receptive field (nCRF) increases neuronal response sparseness. The cellular and network mechanisms underlying increased response sparseness remain largely unexplored. Here we show that combined CRF + nCRF stimulation increases the sparseness, reliability, and precision of spiking and membrane potential responses in classical regular spiking (RSC) pyramidal neurons of cat primary visual cortex. Conversely, fast-spiking interneurons exhibit increased activity and decreased selectivity during CRF + nCRF stimulation. The increased sparseness and reliability of RSC neuron spiking is associated with increased inhibitory barrages and narrower visually evoked synaptic potentials. Our experimental observations were replicated with a simple computational model, suggesting that network interactions among neuronal subtypes ultimately sharpen recurrent excitation, producing specific and reliable visual responses. PMID:20152117
Regression dilution bias: tools for correction methods and sample size calculation.
Berglund, Lars
2012-08-01
Random errors in measurement of a risk factor will introduce downward bias of an estimated association to a disease or a disease marker. This phenomenon is called regression dilution bias. A bias correction may be made with data from a validity study or a reliability study. In this article we give a non-technical description of designs of reliability studies with emphasis on selection of individuals for a repeated measurement, assumptions of measurement error models, and correction methods for the slope in a simple linear regression model where the dependent variable is a continuous variable. Also, we describe situations where correction for regression dilution bias is not appropriate. The methods are illustrated with the association between insulin sensitivity measured with the euglycaemic insulin clamp technique and fasting insulin, where measurement of the latter variable carries noticeable random error. We provide software tools for estimation of a corrected slope in a simple linear regression model assuming data for a continuous dependent variable and a continuous risk factor from a main study and an additional measurement of the risk factor in a reliability study. Also, we supply programs for estimation of the number of individuals needed in the reliability study and for choice of its design. Our conclusion is that correction for regression dilution bias is seldom applied in epidemiological studies. This may cause important effects of risk factors with large measurement errors to be neglected.
Probability techniques for reliability analysis of composite materials
NASA Technical Reports Server (NTRS)
Wetherhold, Robert C.; Ucci, Anthony M.
1994-01-01
Traditional design approaches for composite materials have employed deterministic criteria for failure analysis. New approaches are required to predict the reliability of composite structures since strengths and stresses may be random variables. This report will examine and compare methods used to evaluate the reliability of composite laminae. The two types of methods that will be evaluated are fast probability integration (FPI) methods and Monte Carlo methods. In these methods, reliability is formulated as the probability that an explicit function of random variables is less than a given constant. Using failure criteria developed for composite materials, a function of design variables can be generated which defines a 'failure surface' in probability space. A number of methods are available to evaluate the integration over the probability space bounded by this surface; this integration delivers the required reliability. The methods which will be evaluated are: the first order, second moment FPI methods; second order, second moment FPI methods; the simple Monte Carlo; and an advanced Monte Carlo technique which utilizes importance sampling. The methods are compared for accuracy, efficiency, and for the conservativism of the reliability estimation. The methodology involved in determining the sensitivity of the reliability estimate to the design variables (strength distributions) and importance factors is also presented.
Scaling up digital circuit computation with DNA strand displacement cascades.
Qian, Lulu; Winfree, Erik
2011-06-03
To construct sophisticated biochemical circuits from scratch, one needs to understand how simple the building blocks can be and how robustly such circuits can scale up. Using a simple DNA reaction mechanism based on a reversible strand displacement process, we experimentally demonstrated several digital logic circuits, culminating in a four-bit square-root circuit that comprises 130 DNA strands. These multilayer circuits include thresholding and catalysis within every logical operation to perform digital signal restoration, which enables fast and reliable function in large circuits with roughly constant switching time and linear signal propagation delays. The design naturally incorporates other crucial elements for large-scale circuitry, such as general debugging tools, parallel circuit preparation, and an abstraction hierarchy supported by an automated circuit compiler.
Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves.
Elgendi, Mohamed; Eskofier, Bjoern; Abbott, Derek
2015-07-21
There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG) signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry). The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats). We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design.
NASA Astrophysics Data System (ADS)
Meddings, Nina; Owen, John R.; Garcia-Araez, Nuria
2017-10-01
Lithium ion conducting membranes are important to protect the lithium metal electrode and act as a barrier to crossover species such as polysulphides in Li-S systems, redox mediators in Li-O2 cells or dissolved cathode species or electrolyte oxidation products in high voltage Li-ion batteries. We present an in-situ method for measuring permeability of membranes to crossover redox species. The method employs a 'Swagelok' cell design equipped with a glassy carbon working electrode, in which redox species are placed initially in the counter electrode compartment only. Permeability through the membrane, which separates working and counter electrodes, is determined using a square wave voltammetry technique that allows the concentration of crossover redox species to be evaluated over time with very high precision. We test the method using a model and well-behaved electrochemical system to demonstrate its sensitivity, reproducibility and reliability relative to alternative approaches. This new method offers advantages in terms of small electrolyte volume, and simple, fast, quantitative and in-situ measurement.
Wardak, Cecylia; Grabarczyk, Malgorzata
2016-08-02
A simple, fast and cheap method for monitoring copper and nitrate in drinking water and food products using newly developed solid contact ion-selective electrodes is proposed. Determination of copper and nitrate was performed by application of multiple standard additions technique. The reliability of the obtained results was assessed by comparing them using the anodic stripping voltammetry or spectrophotometry for the same samples. In each case, satisfactory agreement of the results was obtained, which confirms the analytical usefulness of the constructed electrodes.
The determination of antipyrine elimination in saliva by liquid chromatography.
Gartzke, J; Jäger, H
1991-01-01
A simple, fast and reliable liquid chromatographic method for the determination of antipyrine in saliva is described. The elimination of antipyrine is a good indicator for general evaluation of the liver function for dispositional purposes for example in occupational and environmental medicine. The described LC method was compared with a more extensive photometric procedure. The results obtained from both methods show very good correlation. Only one measurement is necessary to determine the antipyrine clearance. Furthermore the antipyrine dosage can be minimized, because of the sensitivity of the HPLC-method.
Note: A simple image processing based fiducial auto-alignment method for sample registration.
Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne
2015-08-01
A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.
NASA Astrophysics Data System (ADS)
Chen, Fan; Huang, Shaoxiong; Ding, Jinjin; Ding, Jinjin; Gao, Bo; Xie, Yuguang; Wang, Xiaoming
2018-01-01
This paper proposes a fast reliability assessing method for distribution grid with distributed renewable energy generation. First, the Weibull distribution and the Beta distribution are used to describe the probability distribution characteristics of wind speed and solar irradiance respectively, and the models of wind farm, solar park and local load are built for reliability assessment. Then based on power system production cost simulation probability discretization and linearization power flow, a optimal power flow objected with minimum cost of conventional power generation is to be resolved. Thus a reliability assessment for distribution grid is implemented fast and accurately. The Loss Of Load Probability (LOLP) and Expected Energy Not Supplied (EENS) are selected as the reliability index, a simulation for IEEE RBTS BUS6 system in MATLAB indicates that the fast reliability assessing method calculates the reliability index much faster with the accuracy ensured when compared with Monte Carlo method.
Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves
Elgendi, Mohamed; Eskofier, Bjoern; Abbott, Derek
2015-01-01
Background There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG) signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Methods Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry). Results The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats). Conclusions We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design. PMID:26197321
AlKhalidi, Bashar A; Shtaiwi, Majed; AlKhatib, Hatim S; Mohammad, Mohammad; Bustanji, Yasser
2008-01-01
A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.
Huxel Bliven, Kellie C; Snyder Valier, Alison R; Bay, R Curtis; Sauers, Eric L
2017-04-01
The Functional Arm Scale for Throwers (FAST) is an upper extremity (UE) region-specific and population-specific patient-reported outcome (PRO) scale developed to measure health-related quality of life in throwers with UE injuries. Stages I and II, described in a companion paper, of FAST development produced a 22-item scale and a 9-item pitcher module. Stage III of scale development, establishing reliability and validity of the FAST, is reported herein. To describe stage III of scale development: reliability and validity of the FAST. Cohort study (diagnosis); Level of evidence, 2. Data from throwing athletes collected over 5 studies were pooled to assess reliability and validity of the FAST. Reliability was estimated using FAST scores from 162 throwing athletes who were injured (n = 23) and uninjured (n = 139). Concurrent validity was estimated using FAST scores and Disabilities of the Arm, Shoulder, and Hand (DASH) and Kerlan-Jobe Orthopaedic Clinic (KJOC) scores from 106 healthy, uninjured throwing athletes. Known-groups validity was estimated using FAST scores from 557 throwing athletes who were injured (n = 142) and uninjured (n = 415). Reliability and validity were assessed using intraclass correlation coefficients (ICCs), and measurement error was assessed using standard error of measurement (SEM) and minimum detectable change (MDC). Receiver operating characteristic curves and sensitivity/specificity values were estimated for known-groups validity. Data from a separate group (n = 18) of postsurgical and nonoperative/conservative rehabilitation patients were analyzed to report responsiveness of the FAST. The FAST total, subscales, and pitcher module scores demonstrated excellent test-retest reliability (ICC, 0.91-0.98). The SEM 95 and MDC 95 for the FAST total score were 3.8 and 10.5 points, respectively. The SEM 95 and MDC 95 for the pitcher module score were 5.7 and 15.7 points, respectively. The FAST scores showed acceptable correlation with DASH (ICC, 0.49-0.82) and KJOC (ICC, 0.62-0.81) scores. The FAST total score classified 85.1% of players into the correct injury group. For predicting UE injury status, a FAST total cutoff score of 10.0 out of 100.0 was 91% sensitive and 75% specific, and a pitcher module score of 10.0 out of 100.0 was 87% sensitive and 78% specific. The FAST total score demonstrated responsiveness on several indices between intake and discharge time points. The FAST is a reliable, valid, and responsive UE region-specific and population-specific PRO scale for measuring patient-reported health care outcomes in throwing athletes with injury.
Huxel Bliven, Kellie C.; Snyder Valier, Alison R.; Bay, R. Curtis; Sauers, Eric L.
2017-01-01
Background: The Functional Arm Scale for Throwers (FAST) is an upper extremity (UE) region-specific and population-specific patient-reported outcome (PRO) scale developed to measure health-related quality of life in throwers with UE injuries. Stages I and II, described in a companion paper, of FAST development produced a 22-item scale and a 9-item pitcher module. Stage III of scale development, establishing reliability and validity of the FAST, is reported herein. Purpose: To describe stage III of scale development: reliability and validity of the FAST. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Data from throwing athletes collected over 5 studies were pooled to assess reliability and validity of the FAST. Reliability was estimated using FAST scores from 162 throwing athletes who were injured (n = 23) and uninjured (n = 139). Concurrent validity was estimated using FAST scores and Disabilities of the Arm, Shoulder, and Hand (DASH) and Kerlan-Jobe Orthopaedic Clinic (KJOC) scores from 106 healthy, uninjured throwing athletes. Known-groups validity was estimated using FAST scores from 557 throwing athletes who were injured (n = 142) and uninjured (n = 415). Reliability and validity were assessed using intraclass correlation coefficients (ICCs), and measurement error was assessed using standard error of measurement (SEM) and minimum detectable change (MDC). Receiver operating characteristic curves and sensitivity/specificity values were estimated for known-groups validity. Data from a separate group (n = 18) of postsurgical and nonoperative/conservative rehabilitation patients were analyzed to report responsiveness of the FAST. Results: The FAST total, subscales, and pitcher module scores demonstrated excellent test-retest reliability (ICC, 0.91-0.98). The SEM95 and MDC95 for the FAST total score were 3.8 and 10.5 points, respectively. The SEM95 and MDC95 for the pitcher module score were 5.7 and 15.7 points, respectively. The FAST scores showed acceptable correlation with DASH (ICC, 0.49-0.82) and KJOC (ICC, 0.62-0.81) scores. The FAST total score classified 85.1% of players into the correct injury group. For predicting UE injury status, a FAST total cutoff score of 10.0 out of 100.0 was 91% sensitive and 75% specific, and a pitcher module score of 10.0 out of 100.0 was 87% sensitive and 78% specific. The FAST total score demonstrated responsiveness on several indices between intake and discharge time points. Conclusion: The FAST is a reliable, valid, and responsive UE region-specific and population-specific PRO scale for measuring patient-reported health care outcomes in throwing athletes with injury. PMID:28451614
NASA Astrophysics Data System (ADS)
Vatanparast, Maryam; Vullum, Per Erik; Nord, Magnus; Zuo, Jian-Min; Reenaas, Turid W.; Holmestad, Randi
2017-09-01
Geometric phase analysis (GPA), a fast and simple Fourier space method for strain analysis, can give useful information on accumulated strain and defect propagation in multiple layers of semiconductors, including quantum dot materials. In this work, GPA has been applied to high resolution Z-contrast scanning transmission electron microscopy (STEM) images. Strain maps determined from different g vectors of these images are compared to each other, in order to analyze and assess the GPA technique in terms of accuracy. The SmartAlign tool has been used to improve the STEM image quality getting more reliable results. Strain maps from template matching as a real space approach are compared with strain maps from GPA, and it is discussed that a real space analysis is a better approach than GPA for aberration corrected STEM images.
[The application of stereology in radiology imaging and cell biology fields].
Hu, Na; Wang, Yan; Feng, Yuanming; Lin, Wang
2012-08-01
Stereology is an interdisciplinary method for 3D morphological study developed from mathematics and morphology. It is widely used in medical image analysis and cell biology studies. Because of its unbiased, simple, fast, reliable and non-invasive characteristics, stereology has been widely used in biomedical areas for quantitative analysis and statistics, such as histology, pathology and medical imaging. Because the stereological parameters show distinct differences in different pathology, many scholars use stereological methods to do quantitative analysis in their studies in recent years, for example, in the areas of the condition of cancer cells, tumor grade, disease development and the patient's prognosis, etc. This paper describes the stereological concept and estimation methods, also illustrates the applications of stereology in the fields of CT images, MRI images and cell biology, and finally reflects the universality, the superiority and reliability of stereology.
Segmentation by fusion of histogram-based k-means clusters in different color spaces.
Mignotte, Max
2008-05-01
This paper presents a new, simple, and efficient segmentation approach, based on a fusion procedure which aims at combining several segmentation maps associated to simpler partition models in order to finally get a more reliable and accurate segmentation result. The different label fields to be fused in our application are given by the same and simple (K-means based) clustering technique on an input image expressed in different color spaces. Our fusion strategy aims at combining these segmentation maps with a final clustering procedure using as input features, the local histogram of the class labels, previously estimated and associated to each site and for all these initial partitions. This fusion framework remains simple to implement, fast, general enough to be applied to various computer vision applications (e.g., motion detection and segmentation), and has been successfully applied on the Berkeley image database. The experiments herein reported in this paper illustrate the potential of this approach compared to the state-of-the-art segmentation methods recently proposed in the literature.
Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy
2017-06-01
Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.
A webcam in Bayer-mode as a light beam profiler for the near infra-red
Langer, Gregor; Hochreiner, Armin; Burgholzer, Peter; Berer, Thomas
2013-01-01
Beam profiles are commonly measured with complementary metal oxide semiconductors (CMOS) or charge coupled devices (CCD). The devices are fast and reliable but expensive. By making use of the fact that the Bayer-filter in commercial webcams is transparent in the near infra-red (>800 nm) and their CCD chips are sensitive up to about 1100 nm, we demonstrate a cheap and simple way to measure laser beam profiles with a resolution down to around ±1 μm, which is close to the resolution of the knife-edge technique. PMID:23645943
A webcam in Bayer-mode as a light beam profiler for the near infra-red.
Langer, Gregor; Hochreiner, Armin; Burgholzer, Peter; Berer, Thomas
2013-05-01
Beam profiles are commonly measured with complementary metal oxide semiconductors (CMOS) or charge coupled devices (CCD). The devices are fast and reliable but expensive. By making use of the fact that the Bayer-filter in commercial webcams is transparent in the near infra-red (>800 nm) and their CCD chips are sensitive up to about 1100 nm, we demonstrate a cheap and simple way to measure laser beam profiles with a resolution down to around ±1 μm, which is close to the resolution of the knife-edge technique.
Invariant approach to the character classification
NASA Astrophysics Data System (ADS)
Šariri, Kristina; Demoli, Nazif
2008-04-01
Image moments analysis is a very useful tool which allows image description invariant to translation and rotation, scale change and some types of image distortions. The aim of this work was development of simple method for fast and reliable classification of characters by using Hu's and affine moment invariants. Measure of Eucleidean distance was used as a discrimination feature with statistical parameters estimated. The method was tested in classification of Times New Roman font letters as well as sets of the handwritten characters. It is shown that using all Hu's and three affine invariants as discrimination set improves recognition rate by 30%.
NASA Astrophysics Data System (ADS)
Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan
2018-04-01
A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.
Simple and fast method for fabrication of endoscopic implantable sensor arrays.
Tahirbegi, I Bogachan; Alvira, Margarita; Mir, Mònica; Samitier, Josep
2014-06-26
Here we have developed a simple method for the fabrication of disposable implantable all-solid-state ion-selective electrodes (ISE) in an array format without using complex fabrication equipment or clean room facilities. The electrodes were designed in a needle shape instead of planar electrodes for a full contact with the tissue. The needle-shape platform comprises 12 metallic pins which were functionalized with conductive inks and ISE membranes. The modified microelectrodes were characterized with cyclic voltammetry, scanning electron microscope (SEM), and optical interferometry. The surface area and roughness factor of each microelectrode were determined and reproducible values were obtained for all the microelectrodes on the array. In this work, the microelectrodes were modified with membranes for the detection of pH and nitrate ions to prove the reliability of the fabricated sensor array platform adapted to an endoscope.
Data transmission protocol for Pi-of-the-Sky cameras
NASA Astrophysics Data System (ADS)
Uzycki, J.; Kasprowicz, G.; Mankiewicz, M.; Nawrocki, K.; Sitek, P.; Sokolowski, M.; Sulej, R.; Tlaczala, W.
2006-10-01
The large amount of data collected by the automatic astronomical cameras has to be transferred to the fast computers in a reliable way. The method chosen should ensure data streaming in both directions but in nonsymmetrical way. The Ethernet interface is very good choice because of its popularity and proven performance. However it requires TCP/IP stack implementation in devices like cameras for full compliance with existing network and operating systems. This paper describes NUDP protocol, which was made as supplement to standard UDP protocol and can be used as a simple-network protocol. The NUDP does not need TCP protocol implementation and makes it possible to run the Ethernet network with simple devices based on microcontroller and/or FPGA chips. The data transmission idea was created especially for the "Pi of the Sky" project.
Closed-loop control of renal perfusion pressure in physiological experiments.
Campos-Delgado, D U; Bonilla, I; Rodríguez-Martínez, M; Sánchez-Briones, M E; Ruiz-Hernández, E
2013-07-01
This paper presents the design, experimental modeling, and control of a pump-driven renal perfusion pressure (RPP)-regulatory system to implement precise and relatively fast RPP regulation in rats. The mechatronic system is a simple, low-cost, and reliable device to automate the RPP regulation process based on flow-mediated occlusion. Hence, the regulated signal is the RPP measured in the left femoral artery of the rat, and the manipulated variable is the voltage applied to a dc motor that controls the occlusion of the aorta. The control system is implemented in a PC through the LabView software, and a data acquisition board NI USB-6210. A simple first-order linear system is proposed to approximate the dynamics in the experiment. The parameters of the model are chosen to minimize the error between the predicted and experimental output averaged from eight input/output datasets at different RPP operating conditions. A closed-loop servocontrol system based on a pole-placement PD controller plus dead-zone compensation was proposed for this purpose. First, the feedback structure was validated in simulation by considering parameter uncertainty, and constant and time-varying references. Several experimental tests were also conducted to validate in real time the closed-loop performance for stepwise and fast switching references, and the results show the effectiveness of the proposed automatic system to regulate the RPP in the rat, in a precise, accurate (mean error less than 2 mmHg) and relatively fast mode (10-15 s of response time).
Stratmann, Philipp; Lakatos, Dominic; Albu-Schäffer, Alin
2016-01-01
There are multiple indications that the nervous system of animals tunes muscle output to exploit natural dynamics of the elastic locomotor system and the environment. This is an advantageous strategy especially in fast periodic movements, since the elastic elements store energy and increase energy efficiency and movement speed. Experimental evidence suggests that coordination among joints involves proprioceptive input and neuromodulatory influence originating in the brain stem. However, the neural strategies underlying the coordination of fast periodic movements remain poorly understood. Based on robotics control theory, we suggest that the nervous system implements a mechanism to accomplish coordination between joints by a linear coordinate transformation from the multi-dimensional space representing proprioceptive input at the joint level into a one-dimensional controller space. In this one-dimensional subspace, the movements of a whole limb can be driven by a single oscillating unit as simple as a reflex interneuron. The output of the oscillating unit is transformed back to joint space via the same transformation. The transformation weights correspond to the dominant principal component of the movement. In this study, we propose a biologically plausible neural network to exemplify that the central nervous system (CNS) may encode our controller design. Using theoretical considerations and computer simulations, we demonstrate that spike-timing-dependent plasticity (STDP) for the input mapping and serotonergic neuromodulation for the output mapping can extract the dominant principal component of sensory signals. Our simulations show that our network can reliably control mechanical systems of different complexity and increase the energy efficiency of ongoing cyclic movements. The proposed network is simple and consistent with previous biologic experiments. Thus, our controller could serve as a candidate to describe the neural control of fast, energy-efficient, periodic movements involving multiple coupled joints.
Stratmann, Philipp; Lakatos, Dominic; Albu-Schäffer, Alin
2016-01-01
There are multiple indications that the nervous system of animals tunes muscle output to exploit natural dynamics of the elastic locomotor system and the environment. This is an advantageous strategy especially in fast periodic movements, since the elastic elements store energy and increase energy efficiency and movement speed. Experimental evidence suggests that coordination among joints involves proprioceptive input and neuromodulatory influence originating in the brain stem. However, the neural strategies underlying the coordination of fast periodic movements remain poorly understood. Based on robotics control theory, we suggest that the nervous system implements a mechanism to accomplish coordination between joints by a linear coordinate transformation from the multi-dimensional space representing proprioceptive input at the joint level into a one-dimensional controller space. In this one-dimensional subspace, the movements of a whole limb can be driven by a single oscillating unit as simple as a reflex interneuron. The output of the oscillating unit is transformed back to joint space via the same transformation. The transformation weights correspond to the dominant principal component of the movement. In this study, we propose a biologically plausible neural network to exemplify that the central nervous system (CNS) may encode our controller design. Using theoretical considerations and computer simulations, we demonstrate that spike-timing-dependent plasticity (STDP) for the input mapping and serotonergic neuromodulation for the output mapping can extract the dominant principal component of sensory signals. Our simulations show that our network can reliably control mechanical systems of different complexity and increase the energy efficiency of ongoing cyclic movements. The proposed network is simple and consistent with previous biologic experiments. Thus, our controller could serve as a candidate to describe the neural control of fast, energy-efficient, periodic movements involving multiple coupled joints. PMID:27014051
Charter, Richard A
2005-12-01
Confidence intervals are provided for the validity coefficients calculated by Veazey, et al. for the M-FAST. Two coefficients alpha are also presented along with suggestions for different approaches to calculating the M-FAST internal consistency reliability.
Hou, Xianlong; Hodges, Ben R; Feng, Dongyu; Liu, Qixiao
2017-03-15
As oil transport increasing in the Texas bays, greater risks of ship collisions will become a challenge, yielding oil spill accidents as a consequence. To minimize the ecological damage and optimize rapid response, emergency managers need to be informed with how fast and where oil will spread as soon as possible after a spill. The state-of-the-art operational oil spill forecast modeling system improves the oil spill response into a new stage. However uncertainty due to predicted data inputs often elicits compromise on the reliability of the forecast result, leading to misdirection in contingency planning. Thus understanding the forecast uncertainty and reliability become significant. In this paper, Monte Carlo simulation is implemented to provide parameters to generate forecast probability maps. The oil spill forecast uncertainty is thus quantified by comparing the forecast probability map and the associated hindcast simulation. A HyosPy-based simple statistic model is developed to assess the reliability of an oil spill forecast in term of belief degree. The technologies developed in this study create a prototype for uncertainty and reliability analysis in numerical oil spill forecast modeling system, providing emergency managers to improve the capability of real time operational oil spill response and impact assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study
Jalali, Amir; Hatamie, Amir; Saferpour, Tahere; Khajeamiri, Alireza; Safa, Tahere; Buazar, Foad
2016-01-01
In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method showed that unambiguous identification can be achieved for MDMA from 3, 4-methylenedioxyamphetamine (MDA), Amphetamine (AM), methamphetamine (MA) and ketamine (Keta) compounds, respectively. The experimental results indicated the acceptable time window without interfering peaks. It is found that GC-MS was provided a suitable and rapid identification approach for MDMA (Ecstacy) tablets, particularly in the Forensic labs. Consequently, the intense MDMA levels would support the police to develop a simple quantification of impurity in Ecstasy tablets. PMID:27610162
Simple and Fast Method for Fabrication of Endoscopic Implantable Sensor Arrays
Tahirbegi, I. Bogachan; Alvira, Margarita; Mir, Mònica; Samitier, Josep
2014-01-01
Here we have developed a simple method for the fabrication of disposable implantable all-solid-state ion-selective electrodes (ISE) in an array format without using complex fabrication equipment or clean room facilities. The electrodes were designed in a needle shape instead of planar electrodes for a full contact with the tissue. The needle-shape platform comprises 12 metallic pins which were functionalized with conductive inks and ISE membranes. The modified microelectrodes were characterized with cyclic voltammetry, scanning electron microscope (SEM), and optical interferometry. The surface area and roughness factor of each microelectrode were determined and reproducible values were obtained for all the microelectrodes on the array. In this work, the microelectrodes were modified with membranes for the detection of pH and nitrate ions to prove the reliability of the fabricated sensor array platform adapted to an endoscope. PMID:24971473
Liang, Jiajie; Chen, Yongsheng; Xu, Yanfei; Liu, Zhibo; Zhang, Long; Zhao, Xin; Zhang, Xiaoliang; Tian, Jianguo; Huang, Yi; Ma, Yanfeng; Li, Feifei
2010-11-01
Owing to its extraordinary electronic property, chemical stability, and unique two-dimensional nanostructure, graphene is being considered as an ideal material for the highly expected all-carbon-based micro/nanoscale electronics. Herein, we present a simple yet versatile approach to constructing all-carbon micro/nanoelectronics using solution-processing graphene films directly. From these graphene films, various graphene-based microcosmic patterns and structures have been fabricated using maskless computer-controlled laser cutting. Furthermore, a complete system involving a prototype of a flexible write-once-read-many-times memory card and a fast data-reading system has been demonstrated, with infinite data retention time and high reliability. These results indicate that graphene could be the ideal material for fabricating the highly demanded all-carbon and flexible devices and electronics using the simple and efficient roll-to-roll printing process when combined with maskless direct data writing.
The Human Brain Project and neuromorphic computing
Calimera, Andrea; Macii, Enrico; Poncino, Massimo
Summary Understanding how the brain manages billions of processing units connected via kilometers of fibers and trillions of synapses, while consuming a few tens of Watts could provide the key to a completely new category of hardware (neuromorphic computing systems). In order to achieve this, a paradigm shift for computing as a whole is needed, which will see it moving away from current “bit precise” computing models and towards new techniques that exploit the stochastic behavior of simple, reliable, very fast, low-power computing devices embedded in intensely recursive architectures. In this paper we summarize how these objectives will be pursued in the Human Brain Project. PMID:24139655
Measurement of Poisson's ratio of nonmetallic materials by laser holographic interferometry
NASA Astrophysics Data System (ADS)
Zhu, Jian T.
1991-12-01
By means of the off-axis collimated plane wave coherent light arrangement and a loading device by pure bending, Poisson's ratio values of CFRP (carbon fiber-reinforced plactics plates, lay-up 0 degree(s), 90 degree(s)), GFRP (glass fiber-reinforced plactics plates, radial direction) and PMMA (polymethyl methacrylate, x, y direction) have been measured. In virtue of this study, the ministry standard for the Ministry of Aeronautical Industry (Testing method for the measurement of Poisson's ratio of non-metallic by laser holographic interferometry) has been published. The measurement process is fast and simple. The measuring results are reliable and accurate.
Foffani, Guglielmo; Uzcategui, Yoryani G; Gal, Beatriz; Menendez de la Prida, Liset
2007-09-20
Ripples are sharp-wave-associated field oscillations (100-300 Hz) recorded in the hippocampus during behavioral immobility and slow-wave sleep. In epileptic rats and humans, a different and faster oscillation (200-600 Hz), termed fast ripples, has been described. However, the basic mechanisms are unknown. Here, we propose that fast ripples emerge from a disorganized ripple pattern caused by unreliable firing in the epileptic hippocampus. Enhanced synaptic activity is responsible for the irregular bursting of CA3 pyramidal cells due to large membrane potential fluctuations. Lower field interactions and a reduced spike-timing reliability concur with decreased spatial synchronization and the emergence of fast ripples. Reducing synaptically driven membrane potential fluctuations improves both spike-timing reliability and spatial synchronization and restores ripples in the epileptic hippocampus. Conversely, a lower spike-timing reliability, with reduced potassium currents, is associated with ripple shuffling in normal hippocampus. Therefore, fast ripples may reflect a pathological desynchronization of the normal ripple pattern.
Don’t make cache too complex: A simple probability-based cache management scheme for SSDs
Cho, Sangyeun; Choi, Jongmoo
2017-01-01
Solid-state drives (SSDs) have recently become a common storage component in computer systems, and they are fueled by continued bit cost reductions achieved with smaller feature sizes and multiple-level cell technologies. However, as the flash memory stores more bits per cell, the performance and reliability of the flash memory degrade substantially. To solve this problem, a fast non-volatile memory (NVM-)based cache has been employed within SSDs to reduce the long latency required to write data. Absorbing small writes in a fast NVM cache can also reduce the number of flash memory erase operations. To maximize the benefits of an NVM cache, it is important to increase the NVM cache utilization. In this paper, we propose and study ProCache, a simple NVM cache management scheme, that makes cache-entrance decisions based on random probability testing. Our scheme is motivated by the observation that frequently written hot data will eventually enter the cache with a high probability, and that infrequently accessed cold data will not enter the cache easily. Owing to its simplicity, ProCache is easy to implement at a substantially smaller cost than similar previously studied techniques. We evaluate ProCache and conclude that it achieves comparable performance compared to a more complex reference counter-based cache-management scheme. PMID:28358897
Don't make cache too complex: A simple probability-based cache management scheme for SSDs.
Baek, Seungjae; Cho, Sangyeun; Choi, Jongmoo
2017-01-01
Solid-state drives (SSDs) have recently become a common storage component in computer systems, and they are fueled by continued bit cost reductions achieved with smaller feature sizes and multiple-level cell technologies. However, as the flash memory stores more bits per cell, the performance and reliability of the flash memory degrade substantially. To solve this problem, a fast non-volatile memory (NVM-)based cache has been employed within SSDs to reduce the long latency required to write data. Absorbing small writes in a fast NVM cache can also reduce the number of flash memory erase operations. To maximize the benefits of an NVM cache, it is important to increase the NVM cache utilization. In this paper, we propose and study ProCache, a simple NVM cache management scheme, that makes cache-entrance decisions based on random probability testing. Our scheme is motivated by the observation that frequently written hot data will eventually enter the cache with a high probability, and that infrequently accessed cold data will not enter the cache easily. Owing to its simplicity, ProCache is easy to implement at a substantially smaller cost than similar previously studied techniques. We evaluate ProCache and conclude that it achieves comparable performance compared to a more complex reference counter-based cache-management scheme.
NASA Technical Reports Server (NTRS)
Jadaan, Osama
2001-01-01
Present capabilities of the NASA CARES/Life (Ceramic Analysis and Reliability Evaluation of Structures/Life) code include probabilistic life prediction of ceramic components subjected to fast fracture, slow crack growth (stress corrosion), and cyclic fatigue failure modes. Currently, this code has the capability to compute the time-dependent reliability of ceramic structures subjected to simple time-dependent loading. For example, in slow crack growth (SCG) type failure conditions CARES/Life can handle the cases of sustained and linearly increasing time-dependent loads, while for cyclic fatigue applications various types of repetitive constant amplitude loads can be accounted for. In real applications applied loads are rarely that simple, but rather vary with time in more complex ways such as, for example, engine start up, shut down, and dynamic and vibrational loads. In addition, when a given component is subjected to transient environmental and or thermal conditions, the material properties also vary with time. The objective of this paper is to demonstrate a methodology capable of predicting the time-dependent reliability of components subjected to transient thermomechanical loads that takes into account the change in material response with time. In this paper, the dominant delayed failure mechanism is assumed to be SCG. This capability has been added to the NASA CARES/Life (Ceramic Analysis and Reliability Evaluation of Structures/Life) code, which has also been modified to have the ability of interfacing with commercially available FEA codes executed for transient load histories. An example involving a ceramic exhaust valve subjected to combustion cycle loads is presented to demonstrate the viability of this methodology and the CARES/Life program.
Reliability of pulse waveform separation analysis: effects of posture and fasting.
Stoner, Lee; Credeur, Daniel; Fryer, Simon; Faulkner, James; Lambrick, Danielle; Gibbs, Bethany Barone
2017-03-01
Oscillometric pulse wave analysis devices enable, with relative simplicity and objectivity, the measurement of central hemodynamic parameters. The important parameters are central blood pressures and indices of arterial wave reflection, including wave separation analysis (backward pressure component Pb and reflection magnitude). This study sought to determine whether the measurement precision (between-day reliability) of Pb and reflection magnitude: exceeds the criterion for acceptable reliability; and is affected by posture (supine, seated) and fasting state. Twenty healthy adults (50% female, 27.9 years, 24.2 kg/m) were tested on six different mornings: 3 days fasted, 3 days nonfasted condition. On each occasion, participants were tested in supine and seated postures. Oscillometric pressure waveforms were recorded on the left upper arm. The criterion intra-class correlation coefficient value of 0.75 was exceeded for Pb (0.76) and reflection magnitude (0.77) when participants were assessed under the combined supine-fasted condition. The intra-class correlation coefficient was lowest for Pb in seated-nonfasted condition (0.57), and lowest for reflection magnitude in the seated-fasted condition (0.56). For Pb, the smallest detectible change that must be exceeded in order for a significant change to occur in an individual was 2.5 mmHg, and for reflection magnitude, the smallest detectable change was 8.5%. Assessments of Pb and reflection magnitude are as follows: exceed the criterion for acceptable reliability; and are most reliable when participants are fasted in a supine position. The demonstrated reliability suggests sufficient precision to detect clinically meaningful changes in reflection magnitude and Pb.
Development and Reliability Testing of a Fast-Food Restaurant Observation Form.
Rimkus, Leah; Ohri-Vachaspati, Punam; Powell, Lisa M; Zenk, Shannon N; Quinn, Christopher M; Barker, Dianne C; Pugach, Oksana; Resnick, Elissa A; Chaloupka, Frank J
2015-01-01
To develop a reliable observational data collection instrument to measure characteristics of the fast-food restaurant environment likely to influence consumer behaviors, including product availability, pricing, and promotion. The study used observational data collection. Restaurants were in the Chicago Metropolitan Statistical Area. A total of 131 chain fast-food restaurant outlets were included. Interrater reliability was measured for product availability, pricing, and promotion measures on a fast-food restaurant observational data collection instrument. Analysis was done with Cohen's κ coefficient and proportion of overall agreement for categorical variables and intraclass correlation coefficient (ICC) for continuous variables. Interrater reliability, as measured by average κ coefficient, was .79 for menu characteristics, .84 for kids' menu characteristics, .92 for food availability and sizes, .85 for beverage availability and sizes, .78 for measures on the availability of nutrition information,.75 for characteristics of exterior advertisements, and .62 and .90 for exterior and interior characteristics measures, respectively. For continuous measures, average ICC was .88 for food pricing measures, .83 for beverage prices, and .65 for counts of exterior advertisements. Over 85% of measures demonstrated substantial or almost perfect agreement. Although some measures required revision or protocol clarification, results from this study suggest that the instrument may be used to reliably measure the fast-food restaurant environment.
Acousto-optic filtering of lidar signals
NASA Technical Reports Server (NTRS)
Kolarov, G.; Deleva, A.; Mitsev, TS.
1992-01-01
The predominant part of the noise in lidar receivers is created by the background radiation; therefore, one of the most important elements of the receiving optics is a spectrally selecting filter placed in front of the photodetector. Interference filters are usually used to transmit a given wavelength. Specific properties of the interference filters, such as simple design, reliability, small size, and large aperture, combined with high transmission coefficient and narrow spectral band, make them the preferred spectral device in many cases. However, problems arise in applications such as the Differential Absorption Lidar (DIAL) technique, where fast tuning within a wide spectral region is necessary. Tunable acousto-optical filters (TAOF), used recently in astrophysical observations to suppress the background radiation, can be employed with success in lidar sounding. They are attractive due to the possibility for fast spectral scanning with a narrow transmission band. The TAOF's advantages are fully evident in DIAL lidars where one must simultaneously receive signals at two laser frequencies.
A simplified controller and detailed dynamics of constant off-time peak current control
NASA Astrophysics Data System (ADS)
Van den Bossche, Alex; Dimitrova, Ekaterina; Valchev, Vencislav; Feradov, Firgan
2017-09-01
A fast and reliable current control is often the base of power electronic converters. The traditional constant frequency peak control is unstable above 50 % duty ratio. In contrast, the constant off-time peak current control (COTCC) is unconditionally stable and fast, so it is worth analyzing it. Another feature of the COTCC is that one can combine a current control together with a current protection. The time dynamics show a zero-transient response, even when the inductor changes in a wide range. It can also be modeled as a special transfer function for all frequencies. The article shows also that it can be implemented in a simple analog circuit using a wide temperature range IC, such as the LM2903, which is compatible with PV conversion and automotive temperature range. Experiments are done using a 3 kW step-up converter. A drawback is still that the principle does not easily fit in usual digital controllers up to now.
NASA Astrophysics Data System (ADS)
Elsheikh, Ahmed A.; Gao, Stephen S.; Liu, Kelly H.; Mohamed, Abdelnasser A.; Yu, Youqiang; Fat-Helbary, Raafat E.
2014-04-01
For most continental areas, the mechanisms leading to mantle fabrics responsible for the observed anisotropy remain ambiguous, partially due to the lack of sufficient spatial coverage of reliable seismological observations. Here we report the first joint analysis of shear-wave splitting measurements obtained at stations on the Arabian and Nubian Plates adjacent to the Red Sea. More than 1100 pairs of high-quality splitting parameters show dominantly N-S fast orientations at all 47 stations and larger-than-normal splitting times beneath the Afro-Arabian Dome (AAD). The uniformly N-S fast orientations and large splitting times up to 1.5 s are inconsistent with significant contributions from the lithosphere, which is about 50-80 km thick beneath the AAD and even thinner beneath the Red Sea. The results can best be explained by simple shear between the lithosphere and the asthenosphere associated with northward subduction of the African/Arabian Plates over the past 150 Ma.
Moro, Maria Francesca; Colom, Francesc; Floris, Francesca; Pintus, Elisa; Pintus, Mirra; Contini, Francesca; Carta, Mauro Giovanni
2012-01-01
Background: Functioning Assessment Short Test (FAST) is a brief instrument designed to assess the main functioning problems experienced by psychiatric patients, specifically bipolar patients. It includes 24 items assessing impairment or disability in six domains of functioning: autonomy, occupational functioning, cognitive functioning, financial issues, interpersonal relationships and leisure time. The aim of this study is to measure the validity and reliability of the Italian version of this instrument. Methods: Twenty-four patients with DSM-IV TR bipolar disorder and 20 healthy controls were recruited and evaluated in three private clinics in Cagliari (Sardinia, Italy). The psychometric properties of FAST (feasibility, internal consistency, concurrent validity, discriminant validity (patients vs controls and eutimic patients vs manic and depressed), and test-retest reliability were analyzed. Results: The internal consistency obtained was very high with a Cronbach's alpha of 0.955. A highly significant negative correlation with GAF was obtained (r = -0.9; p < 0.001) pointing to a reasonable degree of concurrent validity. FAST show a good test-retest reliability between two independent evaluation differing of one week (mean K =0.73). The total FAST scores were lower in controls as compared with Bipolar Patients and in Euthimic patients compared with Depressed or Manic. Conclusion: The Italian version of the FAST showed similar psychometrics properties as far as regard internal consistency and discriminant validity of the original version and show a good test retest reliability measure by means of K statistics. PMID:22905035
Gartzke, J; Jäger, H; Vins, I
1991-01-01
A simple, fast and reliable liquid chromatographic method for the determination of theophylline in serum and capillary blood after a solid phase extraction is described for therapeutic drug monitoring. The employment of capillary blood permits the determination of an individual drug profile and other pharmacokinetic studies in neonates and infants. There were no differences in venous- and capillary-blood levels but these values compared poorly with those in serum. An adjustment of the results by correction of the different volumes of serum and blood by haematocrit was unsuccessful. Differences in the binding of theophylline to erythrocytes could be an explanation for the differences in serum at blood levels of theophylline.
Adenoma of the cloacal scent gland in a California Kingsnake (Lampropeltis getulus californiae).
Gál, János; Mándoki, Míra
2012-12-01
A multiple simple adenoma causing severe distortion of the tail base was identified in the cloacal scent gland of a female California Kingsnake (Lampropeltis getulus californiae). In addition to the normal epithelial layer of the gland and the skin, the tumour cells in the glandular epithelium also showed cross immunereactivity with humanised anti-cytokeratin antibody. This is the first description of an adenoma in the scent gland of a reptile species. Neither epithelial nor mesenchymal tumours arising from the scent gland of reptiles have been reported previously. This report also highlights the possible use of humanised antibodies on reptile species for the fast, reliable and specific differential diagnosis of tumours.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wixson, J. R.
Root cause analysis (RCA) is an important methodology that can be integrated with the VE Job Plan to generate superior results from the VE Methodology. The point at which RCA is most appropriate is after the function analysis and FAST Model have been built and functions for improvement have been chosen. These functions are then subjected to a simple, but, rigorous RCA to get to the root cause of their deficiencies, whether it is high cost/poor value, poor quality, or poor reliability. Once the most probable causes for these problems have been arrived at, better solutions for improvement can bemore » developed in the creativity phase because the team better understands the problems associated with these functions.« less
Berglund, Lars; Garmo, Hans; Lindbäck, Johan; Svärdsudd, Kurt; Zethelius, Björn
2008-09-30
The least-squares estimator of the slope in a simple linear regression model is biased towards zero when the predictor is measured with random error. A corrected slope may be estimated by adding data from a reliability study, which comprises a subset of subjects from the main study. The precision of this corrected slope depends on the design of the reliability study and estimator choice. Previous work has assumed that the reliability study constitutes a random sample from the main study. A more efficient design is to use subjects with extreme values on their first measurement. Previously, we published a variance formula for the corrected slope, when the correction factor is the slope in the regression of the second measurement on the first. In this paper we show that both designs improve by maximum likelihood estimation (MLE). The precision gain is explained by the inclusion of data from all subjects for estimation of the predictor's variance and by the use of the second measurement for estimation of the covariance between response and predictor. The gain of MLE enhances with stronger true relationship between response and predictor and with lower precision in the predictor measurements. We present a real data example on the relationship between fasting insulin, a surrogate marker, and true insulin sensitivity measured by a gold-standard euglycaemic insulin clamp, and simulations, where the behavior of profile-likelihood-based confidence intervals is examined. MLE was shown to be a robust estimator for non-normal distributions and efficient for small sample situations. Copyright (c) 2008 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Filuk, A. B.; Bailey, J. E.; Cuneo, M. E.; Lake, P. W.; Nash, T. J.; Noack, D. D.; Maron, Y.
2000-12-01
The maximum power achieved in a wide variety of high-power devices, including electron and ion diodes, z pinches, and microwave generators, is presently limited by anode-cathode gap breakdown. A frequently discussed hypothesis for this effect is ionization of fast neutral atoms injected throughout the anode-cathode gap during the power pulse. We describe a newly developed diagnostic tool that provides a direct test of this hypothesis. Time-resolved vacuum-ultraviolet absorption spectroscopy is used to directly probe fast neutral atoms with 1-mm spatial resolution in the 10-mm anode-cathode gap of the SABRE 5 MV, 1 TW applied-B ion diode. Absorption spectra collected during Ar RF glow discharges and with CO2 gas fills confirm the reliability of the diagnostic technique. Throughout the 50-100 ns ion diode pulses no measurable neutral absorption was seen, setting upper limits of (0.12-1.5)×1014 cm-3 for ground-state fast neutral atom densities of H, C, N, O, and F. The absence of molecular absorption bands also sets upper limits of (0.16-1.2)×1015 cm-3 for common simple molecules. These limits are low enough to rule out ionization of fast neutral atoms as a breakdown mechanism. Breakdown due to ionization of molecules is also found to be unlikely. This technique can now be applied to quantify the role of neutral atoms in other high-power devices.
Framework for SEM contour analysis
NASA Astrophysics Data System (ADS)
Schneider, L.; Farys, V.; Serret, E.; Fenouillet-Beranger, C.
2017-03-01
SEM images provide valuable information about patterning capability. Geometrical properties such as Critical Dimension (CD) can be extracted from them and are used to calibrate OPC models, thus making OPC more robust and reliable. However, there is currently a shortage of appropriate metrology tools to inspect complex two-dimensional patterns in the same way as one would work with simple one-dimensional patterns. In this article we present a full framework for the analysis of SEM images. It has been proven to be fast, reliable and robust for every type of structure, and particularly for two-dimensional structures. To achieve this result, several innovative solutions have been developed and will be presented in the following pages. Firstly, we will present a new noise filter which is used to reduce noise on SEM images, followed by an efficient topography identifier, and finally we will describe the use of a topological skeleton as a measurement tool that can extend CD measurements on all kinds of patterns.
NASA Astrophysics Data System (ADS)
Mendizabal, A.; González-Díaz, J. B.; San Sebastián, M.; Echeverría, A.
2016-07-01
This paper describes the implementation of a simple strategy adopted for the inherent shrinkage method (ISM) to predict welding-induced distortion. This strategy not only makes it possible for the ISM to reach accuracy levels similar to the detailed transient analysis method (considered the most reliable technique for calculating welding distortion) but also significantly reduces the time required for these types of calculations. This strategy is based on the sequential activation of welding blocks to account for welding direction and transient movement of the heat source. As a result, a significant improvement in distortion prediction is achieved. This is demonstrated by experimentally measuring and numerically analyzing distortions in two case studies: a vane segment subassembly of an aero-engine, represented with 3D-solid elements, and a car body component, represented with 3D-shell elements. The proposed strategy proves to be a good alternative for quickly estimating the correct behaviors of large welded components and may have important practical applications in the manufacturing industry.
Wang, Tong; Wu, Hai-Long; Xie, Li-Xia; Zhu, Li; Liu, Zhi; Sun, Xiao-Dong; Xiao, Rong; Yu, Ru-Qin
2017-04-01
In this work, a smart chemometrics-enhanced strategy, high-performance liquid chromatography, and diode array detection coupled with second-order calibration method based on alternating trilinear decomposition algorithm was proposed to simultaneously quantify 12 polyphenols in different kinds of apple peel and pulp samples. The proposed strategy proved to be a powerful tool to solve the problems of coelution, unknown interferences, and chromatographic shifts in the process of high-performance liquid chromatography analysis, making it possible for the determination of 12 polyphenols in complex apple matrices within 10 min under simple conditions of elution. The average recoveries with standard deviations, and figures of merit including sensitivity, selectivity, limit of detection, and limit of quantitation were calculated to validate the accuracy of the proposed method. Compared to the quantitative analysis results from the classic high-performance liquid chromatography method, the statistical and graphical analysis showed that our proposed strategy obtained more reliable results. All results indicated that our proposed method used in the quantitative analysis of apple polyphenols was an accurate, fast, universal, simple, and green one, and it was expected to be developed as an attractive alternative method for simultaneous determination of multitargeted analytes in complex matrices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A simple and rapid method for optical visualization and quantification of bacteria on textiles
Stiefel, Philipp; Schneider, Jana; Amberg, Caroline; Maniura-Weber, Katharina; Ren, Qun
2016-01-01
To prevent bacterial contamination on textiles and the associated undesired effects different biocidal coatings have been investigated and applied. However, due to health and environmental concerns anti-adhesive coatings preventing the binding of bacteria would be favored. To develop such anti-adhesive coatings simple assays for reliable and fast screening are beneficial. Here an easy-to-handle, robust and rapid assay to assess bacteria on textiles utilizing a tetrazolium salt was reported. The assay allowed direct eye visualization of the color change of the textiles containing bacteria, facilitating fast screening. Quantification of the adhered bacteria could be done by generating standard curves which correlate the staining intensity to cell numbers. An additional advantage of the described assay is that with the same detection method anti-adhesive and biocidal effects can be investigated. The method was applied to different coatings, using Pseudomonas aeruginosa and Staphylococcus aureus as model organisms. The detection limit was found to be between 2.5 * 106 and 9.4 * 108 for P. aeruginosa and between 1 * 106 and 3.3 * 108 for S. aureus. The anti-adhesive coating PLUMA was demonstrated to reduce bacterial adhesion without killing them, whereas the biocidal coating TH22-27 caused a clear reduction in the number of viable cells. PMID:28004762
Brown, A M
2001-06-01
The objective of this present study was to introduce a simple, easily understood method for carrying out non-linear regression analysis based on user input functions. While it is relatively straightforward to fit data with simple functions such as linear or logarithmic functions, fitting data with more complicated non-linear functions is more difficult. Commercial specialist programmes are available that will carry out this analysis, but these programmes are expensive and are not intuitive to learn. An alternative method described here is to use the SOLVER function of the ubiquitous spreadsheet programme Microsoft Excel, which employs an iterative least squares fitting routine to produce the optimal goodness of fit between data and function. The intent of this paper is to lead the reader through an easily understood step-by-step guide to implementing this method, which can be applied to any function in the form y=f(x), and is well suited to fast, reliable analysis of data in all fields of biology.
Simple online recognition of optical data strings based on conservative optical logic
NASA Astrophysics Data System (ADS)
Caulfield, H. John; Shamir, Joseph; Zavalin, Andrey I.; Silberman, Enrique; Qian, Lei; Vikram, Chandra S.
2006-06-01
Optical packet switching relies on the ability of a system to recognize header information on an optical signal. Unless the headers are very short with large Hamming distances, optical correlation fails and optical logic becomes attractive because it can handle long headers with Hamming distances as low as 1. Unfortunately, the only optical logic gates fast enough to keep up with current communication speeds involve semiconductor optical amplifiers and do not lend themselves to the incorporation of large numbers of elements for header recognition and would consume a lot of power as well. The ideal system would operate at any bandwidth with no power consumption. We describe how to design and build such a system by using passive optical logic. This too leads to practical problems that we discuss. We show theoretically various ways to use optical interferometric logic for reliable recognition of long data streams such as headers in optical communication. In addition, we demonstrate one particularly simple experimental approach using interferometric coinc gates.
Flight Research into Simple Adaptive Control on the NASA FAST Aircraft
NASA Technical Reports Server (NTRS)
Hanson, Curtis E.
2011-01-01
A series of simple adaptive controllers with varying levels of complexity were designed, implemented and flight tested on the NASA Full-Scale Advanced Systems Testbed (FAST) aircraft. Lessons learned from the development and flight testing are presented.
Development of a probabilistic analysis methodology for structural reliability estimation
NASA Technical Reports Server (NTRS)
Torng, T. Y.; Wu, Y.-T.
1991-01-01
The novel probabilistic analysis method for assessment of structural reliability presented, which combines fast-convolution with an efficient structural reliability analysis, can after identifying the most important point of a limit state proceed to establish a quadratic-performance function. It then transforms the quadratic function into a linear one, and applies fast convolution. The method is applicable to problems requiring computer-intensive structural analysis. Five illustrative examples of the method's application are given.
Cacho, J; Sevillano, J; de Castro, J; Herrera, E; Ramos, M P
2008-11-01
Insulin resistance plays a role in the pathogenesis of diabetes, including gestational diabetes. The glucose clamp is considered the gold standard for determining in vivo insulin sensitivity, both in human and in animal models. However, the clamp is laborious, time consuming and, in animals, requires anesthesia and collection of multiple blood samples. In human studies, a number of simple indexes, derived from fasting glucose and insulin levels, have been obtained and validated against the glucose clamp. However, these indexes have not been validated in rats and their accuracy in predicting altered insulin sensitivity remains to be established. In the present study, we have evaluated whether indirect estimates based on fasting glucose and insulin levels are valid predictors of insulin sensitivity in nonpregnant and 20-day-pregnant Wistar and Sprague-Dawley rats. We have analyzed the homeostasis model assessment of insulin resistance (HOMA-IR), the quantitative insulin sensitivity check index (QUICKI), and the fasting glucose-to-insulin ratio (FGIR) by comparing them with the insulin sensitivity (SI(Clamp)) values obtained during the hyperinsulinemic-isoglycemic clamp. We have performed a calibration analysis to evaluate the ability of these indexes to accurately predict insulin sensitivity as determined by the reference glucose clamp. Finally, to assess the reliability of these indexes for the identification of animals with impaired insulin sensitivity, performance of the indexes was analyzed by receiver operating characteristic (ROC) curves in Wistar and Sprague-Dawley rats. We found that HOMA-IR, QUICKI, and FGIR correlated significantly with SI(Clamp), exhibited good sensitivity and specificity, accurately predicted SI(Clamp), and yielded lower insulin sensitivity in pregnant than in nonpregnant rats. Together, our data demonstrate that these indexes provide an easy and accurate measure of insulin sensitivity during pregnancy in the rat.
Reja, Abu Hena Hasanoor; De, Abhishek; Biswas, Supratik; Chattopadhyay, Amitabha; Chatterjee, Gobinda; Bhattacharya, Basudev; Sarda, Aarti; Aggarwal, Ishad
2013-01-01
The diagnosis of pure neural leprosy (PNL) remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC) coupled with Ziehl Neelsen staining (ZN staining) and Multiplex-Polymerase Chain Reaction (PCR) specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL), which may be simpler and yet reliable. The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex-PCR. Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4%) with the help of conventional acid-fast staining and 11 cases (84.6%) with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23%) cases showed specific epithelioid cells, whereas 8 (61.5%) cases showed non-specific inflammation, and 2 (15.3%) cases had no inflammatory cells. Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB) and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of PNL.
Sutariya, Pinkesh G; Pandya, Alok; Lodha, Anand; Menon, Shobhana K
2016-01-15
A new, simple, ultra-sensitive and selective approach has been reported for the "on spot" colorimetric detection of creatinine based on calix[4]arene functionalized gold nanoparticles (AuNPs) with excellent discrimination in the presence of other biomolecules. The lower detection limit of the method is 2.16nM. The gold nanoparticles and p-tert-butylcalix[4]arene were synthesized by microwave assisted method. Specifically, in our study, we used dynamic light scattering (DLS) which is a powerful method for the determination of small changes in particle size, improved selectivity and sensitivity of the creatinine detection system over colorimetric method. The nanoassembly is characterized by Transmission electron microscopy (TEM), DLS, UV-vis and ESI-MS spectroscopy, which demonstrates the binding affinity due its ability of hydrogen bonding and electrostatic interaction between -NH group of creatinine and pSDSC4. It exhibits fast response time (<60s) to creatinine and has long shelf-life (>5 weeks). The developed pSDSC4-AuNPs based creatinine biosensor will be established as simple, reliable and accurate tool for the determination of creatinine in human urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro
2015-01-01
Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were <0.50 for 48% of amino acids, 27% of acylcarnitines, 18% of lysophosphatidylcholines and 4% of phosphatidylcholines. In non-fasting samples, the median ICC was 0.54. ICC values were <0.50 for 71% of acylcarnitines, 48% of amino acids, 44% of biogenic amines, 36% of sphingomyelins, 34% of phosphatidylcholines and 33% of lysophosphatidylcholines. Overall, reproducibility was lower in non-fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920
Use of the oral sugar test in ponies when performed with or without prior fasting.
Knowles, E J; Harris, P A; Elliott, J; Menzies-Gow, N J
2017-07-01
It is recommended that the oral sugar test (OST) for insulin dysregulation (ID) be performed after an overnight fast, but fasting is impractical in ponies kept solely at pasture. There are few data on OST repeatability and reliability in ponies. To report 1) whether OST results obtained in the morning after an overnight fast or without fasting in the afternoon (FASTING/FED) can be used interchangeably, 2) time of highest insulin concentration T max [insulin], repeatability and reliability of insulin response to the OST when FASTING or FED and 3) dichotomous agreement (ID/normal) within a small sample when FASTING or FED. Method comparison study. Oral sugar tests were performed on four occasions in 10 adult native British ponies, twice FASTING and twice FED. Insulin concentrations were measured by radioimmunoassay at 0-120 min (T 0,30,60,75,90,120 ). Differences between FASTING and FED results were assessed using mixed effects models. Indices of repeatability and reliability were calculated; dichotomous agreement was reported using kappa statistics. Serum [insulin] was significantly (P≤0.05) higher at T 60 -T 90 with prior fasting (estimated differences [95% confidence intervals]): T 60 : 23.5 μiu/ml (8.7-38.4 μiu/ml), T 75 : 27.1 μiu/ml (12.3-41.8 μiu/ml), T 90 : 15.1 (0.36-29.9 μiu/ml). Most frequently, T max [ins] occurred at T 30 . At any single time point, within-subject coefficients of variation were: FASTING: 40% and FED: 31%. The 95% limits for repeatability were FASTING: 29-340%, FED: 41-240%. Test reliabilities were FASTING: 0.70 and FED: 0.67. For dichotomous interpretation similar results (kappa = 0.7) were obtained using cut-offs of [Insulin] >60 μiu/ml at T 60 or T 90 for FASTING and [Insulin] >51 μiu/ml at T 30 or T 60 for FED samples. Oral sugar tests were performed on a small number of animals on one pasture during one season (spring). Clinicians should beware of interpreting changes in absolute OST results owing to poor repeatability. When stabling is unavailable, OSTs of ponies at pasture may yield similar dichotomous results without prior fasting. © 2016 EVJ Ltd.
Röijezon, Ulrik; Djupsjöbacka, Mats; Björklund, Martin; Häger-Ross, Charlotte; Grip, Helena; Liebermann, Dario G
2010-09-27
Assessment of sensorimotor function is useful for classification and treatment evaluation of neck pain disorders. Several studies have investigated various aspects of cervical motor functions. Most of these have involved slow or self-paced movements, while few have investigated fast cervical movements. Moreover, the reliability of assessment of fast cervical axial rotation has, to our knowledge, not been evaluated before. Cervical kinematics was assessed during fast axial head rotations in 118 women with chronic nonspecific neck pain (NS) and compared to 49 healthy controls (CON). The relationship between cervical kinematics and symptoms, self-rated functioning and fear of movement was evaluated in the NS group. A sub-sample of 16 NS and 16 CON was re-tested after one week to assess the reliability of kinematic variables. Six cervical kinematic variables were calculated: peak speed, range of movement, conjunct movements and three variables related to the shape of the speed profile. Together, peak speed and conjunct movements had a sensitivity of 76% and a specificity of 78% in discriminating between NS and CON, of which the major part could be attributed to peak speed (NS: 226 ± 88°/s and CON: 348 ± 92°/s, p < 0.01). Peak speed was slower in NS compared to healthy controls and even slower in NS with comorbidity of low-back pain. Associations were found between reduced peak speed and self-rated difficulties with running, performing head movements, car driving, sleeping and pain. Peak speed showed reasonably high reliability, while the reliability for conjunct movements was poor. Peak speed of fast cervical axial rotations is reduced in people with chronic neck pain, and even further reduced in subjects with concomitant low back pain. Fast cervical rotation test seems to be a reliable and valid tool for assessment of neck pain disorders on group level, while a rather large between subject variation and overlap between groups calls for caution in the interpretation of individual assessments.
How Root Cause Analysis Can Improve the Value Methodology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wixson, James Robert
2002-05-01
Root cause analysis (RCA) is an important methodology that can be integrated with the VE Job Plan to generate superior results from the VE Methodology. The point at which RCA is most appropriate is after the function analysis and FAST Model have been built and functions for improvement have been chosen. These functions are then subjected to a simple, but, rigorous RCA to get to the root cause of their deficiencies, whether it is high cost/poor value, poor quality, or poor reliability. Once the most probable causes for these problems have been arrived at, better solutions for improvement can bemore » developed in the creativity phase because the team better understands the problems associated with these functions.« less
Barista: A Framework for Concurrent Speech Processing by USC-SAIL
Can, Doğan; Gibson, James; Vaz, Colin; Georgiou, Panayiotis G.; Narayanan, Shrikanth S.
2016-01-01
We present Barista, an open-source framework for concurrent speech processing based on the Kaldi speech recognition toolkit and the libcppa actor library. With Barista, we aim to provide an easy-to-use, extensible framework for constructing highly customizable concurrent (and/or distributed) networks for a variety of speech processing tasks. Each Barista network specifies a flow of data between simple actors, concurrent entities communicating by message passing, modeled after Kaldi tools. Leveraging the fast and reliable concurrency and distribution mechanisms provided by libcppa, Barista lets demanding speech processing tasks, such as real-time speech recognizers and complex training workflows, to be scheduled and executed on parallel (and/or distributed) hardware. Barista is released under the Apache License v2.0. PMID:27610047
Principles and Applications of Liquid Chromatography-Mass Spectrometry in Clinical Biochemistry
Pitt, James J
2009-01-01
Liquid chromatography-mass spectrometry (LC-MS) is now a routine technique with the development of electrospray ionisation (ESI) providing a simple and robust interface. It can be applied to a wide range of biological molecules and the use of tandem MS and stable isotope internal standards allows highly sensitive and accurate assays to be developed although some method optimisation is required to minimise ion suppression effects. Fast scanning speeds allow a high degree of multiplexing and many compounds can be measured in a single analytical run. With the development of more affordable and reliable instruments, LC-MS is starting to play an important role in several areas of clinical biochemistry and compete with conventional liquid chromatography and other techniques such as immunoassay. PMID:19224008
Versatile module for experiments with focussing neutron guides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, T.; Pfleiderer, C.; Böni, P.
2014-09-22
We report the development of a versatile module that permits fast and reliable use of focussing neutron guides under varying scattering angles. A simple procedure for setting up the module and neutron guides is illustrated by typical intensity patterns to highlight operational aspects as well as typical parasitic artefacts. Combining a high-precision alignment table with separate housings for the neutron guides on kinematic mounts, the change-over between neutron guides with different focussing characteristics requires no readjustments of the experimental setup. Exploiting substantial gain factors, we demonstrate the performance of this versatile neutron scattering module in a study of the effectsmore » of uniaxial stress on the domain populations in the transverse spin density wave phase of single crystal Cr.« less
Distribution and release of human pancreatic polypeptide.
Adrian, T E; Bloom, S R; Bryant, M G; Polak, J M; Heitz, P H; Barnes, A J
1976-12-01
A simple and reliable radioimmunoassay has been developed for a new gut hormone, HPP. In the primate 93% of the total PP was found in the pancreas with a small amount throughout the remaining gastrointestinal tract. HPP has been shown to be produced by a number of pancreatic apudomas and their metastases. The immunoreactive PP from these tumours and from normal pancreas was chromatographically indistinguishable from the pure peptide. The plasma PP concentration rose rapidly after a meal in normal subjects and was still raised six hours later. Fasting plasma PP levels in patients with PP cell containing pancreatic endocrine tumours were higher than even the postprandial level in normal subjects. PP measurements is thus useful in diagnosis of pancreatic endocrine tumours.
Distribution and release of human pancreatic polypeptide.
Adrian, T E; Bloom, S R; Bryant, M G; Polak, J M; Heitz, P H; Barnes, A J
1976-01-01
A simple and reliable radioimmunoassay has been developed for a new gut hormone, HPP. In the primate 93% of the total PP was found in the pancreas with a small amount throughout the remaining gastrointestinal tract. HPP has been shown to be produced by a number of pancreatic apudomas and their metastases. The immunoreactive PP from these tumours and from normal pancreas was chromatographically indistinguishable from the pure peptide. The plasma PP concentration rose rapidly after a meal in normal subjects and was still raised six hours later. Fasting plasma PP levels in patients with PP cell containing pancreatic endocrine tumours were higher than even the postprandial level in normal subjects. PP measurements is thus useful in diagnosis of pancreatic endocrine tumours. Images Fig. 2 PMID:828120
Barista: A Framework for Concurrent Speech Processing by USC-SAIL.
Can, Doğan; Gibson, James; Vaz, Colin; Georgiou, Panayiotis G; Narayanan, Shrikanth S
2014-05-01
We present Barista, an open-source framework for concurrent speech processing based on the Kaldi speech recognition toolkit and the libcppa actor library. With Barista, we aim to provide an easy-to-use, extensible framework for constructing highly customizable concurrent (and/or distributed) networks for a variety of speech processing tasks. Each Barista network specifies a flow of data between simple actors, concurrent entities communicating by message passing, modeled after Kaldi tools. Leveraging the fast and reliable concurrency and distribution mechanisms provided by libcppa, Barista lets demanding speech processing tasks, such as real-time speech recognizers and complex training workflows, to be scheduled and executed on parallel (and/or distributed) hardware. Barista is released under the Apache License v2.0.
Dual-beam laser autofocusing system based on liquid lens
NASA Astrophysics Data System (ADS)
Zhang, Fumin; Yao, Yannan; Qu, Xinghua; Zhang, Tong; Pei, Bing
2017-02-01
A dual-beam laser autofocusing system is designed in this paper. The autofocusing system is based on a liquid lens with less moving parts and fast response time, which makes the system simple, reliable, compact and fast. A novel scheme ;Time-sharing focus, fast conversion; is innovatively proposed. The scheme effectively solves the problem that the guiding laser and the working laser cannot focus at the same target point because of the existence of chromatic aberration. This scheme not only makes both guiding laser and working laser achieve optimal focusing in guiding stage and working stage respectively, but also greatly reduces the system complexity and simplifies the focusing process as well as makes autofocusing time of the working laser reduce to about 10 ms. In the distance range of 1 m to 30 m, the autofocusing spot size is kept under 4.3 mm at 30 m and just 0.18 mm at 1 m. The spot size is much less influenced by the target distance compared with the collimated laser with a micro divergence angle for its self-adaptivity. The dual-beam laser autofocusing system based on liquid lens is fully automatic, compact and efficient. It is fully meet the need of dynamicity and adaptivity and it will play an important role in a number of long-range control applications.
Michalke, Bernhard
2017-03-01
Boron exposure is of interest and concern from an occupational point of view. Usual daily boron intake is related to boron blood plasma concentration <1mg/L and to <3mg/L in urine, but after exposure urine concentrations are quickly elevated. Reliable boron biomonitoring, typically in urine, thus is mandatory for occupational health control institutions. This paper reports on the development of a simple, fast and reliable boron determination procedure based on inductively coupled plasma - optical emission spectrometry (ICP-OES). Major aims for this method were simplicity in sample preparation, low risk for artifacts and interferences, high precision and accuracy, possibly low costs, including lower costs for element selective detection, short total analysis time and suitability for occupational health laboratories. Precision data (serial or day-to-day) from urine and doped urine were very good: <1.5 or <2%. Accuracy was calculated from analysis of a certified reference material (ERM-CD 281), as 99% or according to recoveries of doped concentrations ranging from 102 to 109% recovery. For cross-checking ICP-OES determinations, samples were analyzed also by quadrupole ICP-qMS and by sectorfield ICP-sf-MS at low and medium resolution. Both systems confirmed ICP-OES measurements when using 11 B for quantification. Determinations based on 10 B however showed some bias, except with ICP-sf-MS at medium resolution. The observed elevated signals are discussed with respect to the known Ne ++ interference (as an impurity in Ar), which is not separated in low resolving quadrupole ICP-MS systems or ICP-sf-MS at low resolution. Copyright © 2016 Elsevier GmbH. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filuk, A. B.; Bailey, J. E.; Cuneo, M. E.
The maximum power achieved in a wide variety of high-power devices, including electron and ion diodes, z pinches, and microwave generators, is presently limited by anode-cathode gap breakdown. A frequently discussed hypothesis for this effect is ionization of fast neutral atoms injected throughout the anode-cathode gap during the power pulse. We describe a newly developed diagnostic tool that provides a direct test of this hypothesis. Time-resolved vacuum-ultraviolet absorption spectroscopy is used to directly probe fast neutral atoms with 1-mm spatial resolution in the 10-mm anode-cathode gap of the SABRE 5 MV, 1 TW applied-B ion diode. Absorption spectra collected duringmore » Ar RF glow discharges and with CO{sub 2} gas fills confirm the reliability of the diagnostic technique. Throughout the 50--100 ns ion diode pulses no measurable neutral absorption was seen, setting upper limits of (0.12--1.5)x10{sup 14}cm{sup -3} for ground-state fast neutral atom densities of H, C, N, O, and F. The absence of molecular absorption bands also sets upper limits of (0.16--1.2)x10{sup 15}cm{sup -3} for common simple molecules. These limits are low enough to rule out ionization of fast neutral atoms as a breakdown mechanism. Breakdown due to ionization of molecules is also found to be unlikely. This technique can now be applied to quantify the role of neutral atoms in other high-power devices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eylenceoğlu, E.; Rafatov, I., E-mail: rafatov@metu.edu.tr; Kudryavtsev, A. A.
2015-01-15
Two-dimensional hybrid Monte Carlo–fluid numerical code is developed and applied to model the dc glow discharge. The model is based on the separation of electrons into two parts: the low energetic (slow) and high energetic (fast) electron groups. Ions and slow electrons are described within the fluid model using the drift-diffusion approximation for particle fluxes. Fast electrons, represented by suitable number of super particles emitted from the cathode, are responsible for ionization processes in the discharge volume, which are simulated by the Monte Carlo collision method. Electrostatic field is obtained from the solution of Poisson equation. The test calculations weremore » carried out for an argon plasma. Main properties of the glow discharge are considered. Current-voltage curves, electric field reversal phenomenon, and the vortex current formation are developed and discussed. The results are compared to those obtained from the simple and extended fluid models. Contrary to reports in the literature, the analysis does not reveal significant advantages of existing hybrid methods over the extended fluid model.« less
Transient Reliability Analysis Capability Developed for CARES/Life
NASA Technical Reports Server (NTRS)
Nemeth, Noel N.
2001-01-01
The CARES/Life software developed at the NASA Glenn Research Center provides a general-purpose design tool that predicts the probability of the failure of a ceramic component as a function of its time in service. This award-winning software has been widely used by U.S. industry to establish the reliability and life of a brittle material (e.g., ceramic, intermetallic, and graphite) structures in a wide variety of 21st century applications.Present capabilities of the NASA CARES/Life code include probabilistic life prediction of ceramic components subjected to fast fracture, slow crack growth (stress corrosion), and cyclic fatigue failure modes. Currently, this code can compute the time-dependent reliability of ceramic structures subjected to simple time-dependent loading. For example, in slow crack growth failure conditions CARES/Life can handle sustained and linearly increasing time-dependent loads, whereas in cyclic fatigue applications various types of repetitive constant-amplitude loads can be accounted for. However, in real applications applied loads are rarely that simple but vary with time in more complex ways such as engine startup, shutdown, and dynamic and vibrational loads. In addition, when a given component is subjected to transient environmental and or thermal conditions, the material properties also vary with time. A methodology has now been developed to allow the CARES/Life computer code to perform reliability analysis of ceramic components undergoing transient thermal and mechanical loading. This means that CARES/Life will be able to analyze finite element models of ceramic components that simulate dynamic engine operating conditions. The methodology developed is generalized to account for material property variation (on strength distribution and fatigue) as a function of temperature. This allows CARES/Life to analyze components undergoing rapid temperature change in other words, components undergoing thermal shock. In addition, the capability has been developed to perform reliability analysis for components that undergo proof testing involving transient loads. This methodology was developed for environmentally assisted crack growth (crack growth as a function of time and loading), but it will be extended to account for cyclic fatigue (crack growth as a function of load cycles) as well.
Martins, Magda Targa; Melo, Jéssica; Barreto, Fabiano; Hoff, Rodrigo Barcellos; Jank, Louise; Bittencourt, Michele Soares; Arsand, Juliana Bazzan; Schapoval, Elfrides Eva Scherman
2014-11-01
In routine laboratory work, screening methods for multiclass analysis can process a large number of samples in a short time. The main challenge is to develop a methodology to detect as many different classes of residues as possible, combined with speed and low cost. An efficient technique for the analysis of multiclass antibacterial residues (fluoroquinolones, tetracyclines, sulfonamides and trimethoprim) was developed based on simple, environment-friendly extraction for bovine milk, cattle and poultry liver. Acidified ethanol was used as an extracting solvent for milk samples. Liver samples were treated using EDTA-washed sand for cell disruption, methanol:water and acidified acetonitrile as extracting solvent. A total of 24 antibacterial residues were detected and confirmed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), at levels between 10, 25 and 50% of the maximum residue limit (MRL). For liver samples a metabolite (sulfaquinoxaline-OH) was also monitored. A validation procedure was conducted for screening purposes in accordance with European Union requirements (2002/657/EC). The detection capability (CCβ) false compliant rate was less than 5% at the lowest level for each residue. Specificity and ruggedness were also discussed. Incurred and routine samples were analyzed and the method was successfully applied. The results proved that this method can be an important tool in routine analysis, since it is very fast and reliable. Copyright © 2014. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
FILUK,A.B.; BAILEY,JAMES E.; CUNEO,MICHAEL E.
The maximum power achieved in a wide variety of high-power devices, including electron and ion diodes, z pinches, and microwave generators, is presently limited by anode-cathode gap breakdown. A frequently-discussed hypothesis for this effect is ionization of fast neutral atoms injected throughout the anode-cathode gap during the power pulse. The authors describe a newly-developed diagnostic tool that provides the first direct test of this hypothesis. Time-resolved vacuum-ultraviolet absorption spectroscopy is used to directly probe fast neutral atoms with 1 mm spatial resolution in the 10 mm anode-cathode gap of the SABRE 5 MV, 1 TW applied-B ion diode. Absorption spectramore » collected during Ar RF glow discharges and with CO{sub 2} gas fills confirm the reliability of the diagnostic technique. Throughout the 50--100 ns ion diode pulses no measurable neutral absorption is seen, setting upper limits of 0.12--1.5 x 10{sup 14} cm{sup {minus}3} for ground state fast neutral atom densities of H, C, N, O, F. The absence of molecular absorption bands also sets upper limits of 0.16--1.2 x 10{sup 15} cm{sup {minus}3} for common simple molecules. These limits are low enough to rule out ionization throughout the gap as a breakdown mechanism. This technique can now be applied to quantify the role of neutral atoms in other high-power devices.« less
NASA Astrophysics Data System (ADS)
Ghaffarian, Saman; Ghaffarian, Salar
2014-11-01
This paper proposes an improved FastICA model named as Purposive FastICA (PFICA) with initializing by a simple color space transformation and a novel masking approach to automatically detect buildings from high resolution Google Earth imagery. ICA and FastICA algorithms are defined as Blind Source Separation (BSS) techniques for unmixing source signals using the reference data sets. In order to overcome the limitations of the ICA and FastICA algorithms and make them purposeful, we developed a novel method involving three main steps: 1-Improving the FastICA algorithm using Moore-Penrose pseudo inverse matrix model, 2-Automated seeding of the PFICA algorithm based on LUV color space and proposed simple rules to split image into three regions; shadow + vegetation, baresoil + roads and buildings, respectively, 3-Masking out the final building detection results from PFICA outputs utilizing the K-means clustering algorithm with two number of clusters and conducting simple morphological operations to remove noises. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.6% and 85.5% overall pixel-based and object-based precision performances, respectively.
Chericoni, Silvio; Stefanelli, Fabio; Da Valle, Ylenia; Giusiani, Mario
2015-09-01
A sensitive and reliable method for extraction and quantification of benzoylecgonine (BZE) and cocaine (COC) in urine is presented. Propyl-chloroformate was used as derivatizing agent, and it was directly added to the urine sample: the propyl derivative and COC were then recovered by liquid-liquid extraction procedure. Gas chromatography-mass spectrometry was used to detect the analytes in selected ion monitoring mode. The method proved to be precise for BZE and COC both in term of intraday and interday analysis, with a coefficient of variation (CV)<6%. Limits of detection (LOD) were 2.7 ng/mL for BZE and 1.4 ng/mL for COC. The calibration curve showed a linear relationship for BZE and COC (r2>0.999 and >0.997, respectively) within the range investigated. The method, applied to thirty authentic samples, showed to be very simple, fast, and reliable, so it can be easily applied in routine analysis for the quantification of BZE and COC in urine samples. © 2015 American Academy of Forensic Sciences.
Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G
2017-03-15
The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.
Christian, Nicole Townsend; Burlew, Clay Cothren; Moore, Ernest E; Geddes, Andrea E; Wagenaar, Amy E; Fox, Charles J; Pieracci, Fredric M
2018-06-01
The focused abdominal sonography for trauma (FAST) examination has been reported to be unreliable in pelvic fracture patients. Additionally, given the advent of new therapeutic interventions, such as resuscitative endovascular balloon occlusion of the aorta (REBOA), rapid identification of intra-abdominal hemorrhage compared with Zone III hemorrhage may guide different therapeutic strategies. We hypothesized that FAST is reliable for detecting clinically significant intra-abdominal hemorrhage in the face of complex pelvic fractures. Our pelvic fracture database of all hemodynamically unstable patients requiring intervention from January 1, 2005, to July 1, 2015, was reviewed. The FAST examination was compared with operative and computed tomography (CT) scan findings. Confirmatory evaluation for FAST(-) patients was considered positive if therapeutic intervention was required. During the study period, 81 patients in refractory shock with FAST imaging in our emergency department (ED) underwent pelvic packing. Mean age was 45 ± 2 years and Injury Severity Score was 50 ± 1.5. The FAST examination was negative in 53 patients; 52 patients did not require operative intervention for abdominal bleeding while one patient required splenectomy. The FAST examination was positive in 28 patients; 26 had findings confirmed by CT or laparotomy while two patients did not have intra-abdominal hemorrhage on further evaluation. The sensitivity and specificity for FAST in this population was 96% and 96%, respectively, positive predictive value was 93%, and negative predictive value was 98%. The false-negative and -positive rates for FAST were 2% and 7%. Focused abdominal sonography for trauma examination reliably identifies clinically significant hemoperitoneum in life-threatening, pelvic fracture related hemorrhage. The incidence of a false-negative FAST in this unstable pelvic fracture population was 2%. FAST results may be used when determining the role of REBOA in these multisystem trauma patients and requires further study. REBOA placement should be considered in hemodynamically unstable pelvic fracture patients who are FAST(-), while laparotomy should be used in FAST(+) patients. Therapeutic, level IV.
A Simple and Reliable Method of Design for Standalone Photovoltaic Systems
NASA Astrophysics Data System (ADS)
Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.
2017-06-01
Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.
Wu, Wenjie; Zhang, Yuan; Wu, Hanqiu; Zhou, Weie; Cheng, Yan; Li, Hongna; Zhang, Chuanbin; Li, Lulu; Huang, Ying; Zhang, Feng
2017-07-01
Isoflavones are natural substances that exhibit hormone-like pharmacological activities. The separation of isoflavones remains an analytical challenge because of their similar structures. We show that ultra-high performance supercritical fluid chromatography can be an appropriate tool to achieve the fast separation of 12 common dietary isoflavones. Among the five tested columns the Torus DEA column was found to be the most effective column for the separation of these isoflavones. The impact of individual parameters on the retention time and separation factor was evaluated. These parameters were optimized to develop a simple, rapid, and green method for the separation of the 12 target analytes. It only took 12.91 min using gradient elution with methanol as an organic modifier and formic acid as an additive. These isoflavones were determined with limit of quantitation ranging from 0.10 to 0.50 μg/mL, which was sufficient for reliable determination of various matrixes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Non-enzymatic detection of glucose using poly(azure A)-nickel modified glassy carbon electrode.
Liu, Tong; Luo, Yiqun; Zhu, Jiaming; Kong, Liyan; Wang, Wen; Tan, Liang
2016-08-15
A simple, sensitive and selective non-enzymatic glucose sensor was constructed in this paper. The poly(azure A)-nickel modified glassy carbon electrode was successfully fabricated by the electropolymerization of azure A and the adsorption of Ni(2+). The Ni modified electrode, which was characterized by scanning electron microscope, cyclic voltammetry, electrochemical impedance spectra and X-ray photoelectron spectroscopy measurements, respectively, displayed well-defined current responses of the Ni(III)/Ni(II) couple and showed a good activity for electrocatalytic oxidation of glucose in alkaline medium. Under the optimized conditions, the developed sensor exhibited a broad linear calibration range of 5 μM-12mM for quantification of glucose and a low detection limit of 0.64μM (3σ). The excellent analytical performance including simple structure, fast response time, good anti-interference ability, satisfying stability and reliable reproducibility were also found from the proposed amperometric sensor. The results were satisfactory for the determination of glucose in human serum samples as comparison to those from a local hospital. Copyright © 2016 Elsevier B.V. All rights reserved.
Salehifar, Mehdi; Moreno-Equilaz, Manuel
2016-01-01
Due to its fault tolerance, a multiphase brushless direct current (BLDC) motor can meet high reliability demand for application in electric vehicles. The voltage-source inverter (VSI) supplying the motor is subjected to open circuit faults. Therefore, it is necessary to design a fault-tolerant (FT) control algorithm with an embedded fault diagnosis (FD) block. In this paper, finite control set-model predictive control (FCS-MPC) is developed to implement the fault-tolerant control algorithm of a five-phase BLDC motor. The developed control method is fast, simple, and flexible. A FD method based on available information from the control block is proposed; this method is simple, robust to common transients in motor and able to localize multiple open circuit faults. The proposed FD and FT control algorithm are embedded in a five-phase BLDC motor drive. In order to validate the theory presented, simulation and experimental results are conducted on a five-phase two-level VSI supplying a five-phase BLDC motor. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
2010-01-01
Background Assessment of sensorimotor function is useful for classification and treatment evaluation of neck pain disorders. Several studies have investigated various aspects of cervical motor functions. Most of these have involved slow or self-paced movements, while few have investigated fast cervical movements. Moreover, the reliability of assessment of fast cervical axial rotation has, to our knowledge, not been evaluated before. Methods Cervical kinematics was assessed during fast axial head rotations in 118 women with chronic nonspecific neck pain (NS) and compared to 49 healthy controls (CON). The relationship between cervical kinematics and symptoms, self-rated functioning and fear of movement was evaluated in the NS group. A sub-sample of 16 NS and 16 CON was re-tested after one week to assess the reliability of kinematic variables. Six cervical kinematic variables were calculated: peak speed, range of movement, conjunct movements and three variables related to the shape of the speed profile. Results Together, peak speed and conjunct movements had a sensitivity of 76% and a specificity of 78% in discriminating between NS and CON, of which the major part could be attributed to peak speed (NS: 226 ± 88 °/s and CON: 348 ± 92 °/s, p < 0.01). Peak speed was slower in NS compared to healthy controls and even slower in NS with comorbidity of low-back pain. Associations were found between reduced peak speed and self-rated difficulties with running, performing head movements, car driving, sleeping and pain. Peak speed showed reasonably high reliability, while the reliability for conjunct movements was poor. Conclusions Peak speed of fast cervical axial rotations is reduced in people with chronic neck pain, and even further reduced in subjects with concomitant low back pain. Fast cervical rotation test seems to be a reliable and valid tool for assessment of neck pain disorders on group level, while a rather large between subject variation and overlap between groups calls for caution in the interpretation of individual assessments. PMID:20875135
Quick release latch for reactor scram
Johnson, Melvin L.; Shawver, Bruce M.
1976-01-01
A simple, reliable, and fast-acting means for releasing a control element and allowing it to be inserted rapidly into the core region of a nuclear reactor for scram purposes. A latch mechanism grips a coupling head on a nuclear control element to connect the control element to the control drive assembly. The latch mechanism is closed by tensioning a cable or rod with an actuator. The control element is released by de-energizing the actuator, providing fail-safe, rapid release of the control element to effect reactor shutdown. A sensing rod provides indication that the control element is properly positioned in the latch. Two embodiments are illustrated, one involving a collet-type latch mechanism, the other a pliers-type latch mechanism with the actuator located inside the reactor vessel.
Lai, Yiu Wai; Krause, Michael; Savan, Alan; Thienhaus, Sigurd; Koukourakis, Nektarios; Hofmann, Martin R; Ludwig, Alfred
2011-10-01
A high-throughput characterization technique based on digital holography for mapping film thickness in thin-film materials libraries was developed. Digital holographic microscopy is used for fully automatic measurements of the thickness of patterned films with nanometer resolution. The method has several significant advantages over conventional stylus profilometry: it is contactless and fast, substrate bending is compensated, and the experimental setup is simple. Patterned films prepared by different combinatorial thin-film approaches were characterized to investigate and demonstrate this method. The results show that this technique is valuable for the quick, reliable and high-throughput determination of the film thickness distribution in combinatorial materials research. Importantly, it can also be applied to thin films that have been structured by shadow masking.
Quick release latch for reactor scram
Johnson, M.L.; Shawver, B.M.
1975-09-16
A simple, reliable, and fast-acting means for releasing a control element and allowing it to be inserted rapidly into the core region of a nuclear reactor for scram purposes is described. A latch mechanism grips a coupling head on a nuclear control element to connect the control element to the control drive assembly. The latch mechanism is closed by tensioning a cable or rod with an actuator. The control element is released by de-energizing the actuator, providing fail-safe, rapid release of the control element to effect reactor shutdown. A sensing rod provides indication that the control element is properly positioned in the latch. Two embodiments are illustrated, one involving a collet- type latch mechanism, the other a pliers-type latch mechanism with the actuator located inside the reactor vessel. (auth)
Remote observing environment using a KVM-over-IP for the OAO 188 cm telescope
NASA Astrophysics Data System (ADS)
Yanagisawa, Kenshi; Inoue, Goki; Kuroda, Daisuke; Ukita, Nobuharu; Mizumoto, Yoshihiko; Izumiura, Hideyuki
2016-08-01
We have prepared remote observing environment for the 188 cm telescope at Okayama Astrophysical Observatory. A KVM-over-IP and a VPN gateway are employed as core devices, which offer reliable, secure and fast link between on site and remote sites. We have confirmed the KVM-over-IP has ideal characteristics for serving the remote observing environment; the use is simple for both users and maintainer; access from any platform is available; multiple and simultaneous access is possible; and maintenance load is small. We also demonstrated that the degradation of observing efficiency specific to the remote observing is negligibly small. The remote observing environment has fully opened since the semester 2016A, about 30% of the total observing time in the last semester was occupied by remote observing.
Determination of Diffusion Parameters of CO2 Through Microporous PTFE Using a Potentiometric Method
NASA Astrophysics Data System (ADS)
Tarsiche, I.; Ciurchea, D.
Dk values at the diffusion of CO2 through microporous PTFE of 1 to 7 × 10- 7 cm2 s- 1 in the concentration range from 4 × 10- 4 to 0.22 g/l CO2 are determined using a simple, fast and reliable potentiometric method. The method is based on the least-squares fitting of the potential versus time response of a self made CO2 sensitive Severinghaus type sensor with PTFE as a gas-permeable membrane. The obtained results are in good agreement with other reported literature data, both experimental or calculated ones using molecular dynamics simulations. The proposed technique is very sensitive especially at low concentrations of gas and may be used for the study of other polymeric membranes too.
Lima, Fabricio O.; Silva, Gisele S.; Furie, Karen L.; Frankel, Michael R.; Lev, Michael H.; Camargo, Érica CS; Haussen, Diogo C.; Singhal, Aneesh B.; Koroshetz, Walter J.; Smith, Wade S.; Nogueira, Raul G.
2016-01-01
Background and Purpose Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. Methods The FAST-ED scale was based on items of the NIHSS with higher predictive value for LVOS and tested in the STOPStroke cohort, in which patients underwent CT angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial-ICA, MCA-M1, MCA-2, or basilar arteries. Patients with partial, bi-hemispheric, and/or anterior + posterior circulation occlusions were excluded. Receiver operating characteristic (ROC) curve, sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of FAST-ED were compared with the NIHSS, Rapid Arterial oCclusion Evaluation (RACE) scale and Cincinnati Prehospital Stroke Severity Scale (CPSSS). Results LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the ROC curve: FAST-ED=0.81 as reference; NIHSS=0.80, p=0.28; RACE=0.77, p=0.02; and CPSS=0.75, p=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity 0.89, PPV 0.72, and NPV 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, 0.79 and CPSS ≥2 of 0.56, 0.85, 0.65, 0.78, respectively. Conclusions FAST-ED is a simple scale that if successfully validated in the field may be used by medical emergency professionals to identify LVOS in the pre-hospital setting enabling rapid triage of patients. PMID:27364531
Current Barriers to Successful Implementation of FIST Principles
2013-07-01
risks will surface during development that could not have been predicted. Managing a thin budget with no schedule slack for these unknown-unknowns is...Fleischer » Keywords: Fast, Inexpensive, Simple, Tiny (FIST); Program Management ; Heuristics; Innovation; Oversight Current Barriers to Successful...Implementation of FIST Principles Capt Brandon Keller, USAF, and Lt Col J. Robert Wirthlin, USAF The Fast, Inexpensive, Simple, and Tiny (FIST
Application of a swarm-based approach for phase unwrapping
NASA Astrophysics Data System (ADS)
da S. Maciel, Lucas; Albertazzi G., Armando, Jr.
2014-07-01
An algorithm for phase unwrapping based on swarm intelligence is proposed. The novel approach is based on the emergent behavior of swarms. This behavior is the result of the interactions between independent agents following a simple set of rules and is regarded as fast, flexible and robust. The rules here were designed with two purposes. Firstly, the collective behavior must result in a reliable map of the unwrapped phase. The unwrapping reliability was evaluated by each agent during run-time, based on the quality of the neighboring pixels. In addition, the rule set must result in a behavior that focuses on wrapped regions. Stigmergy and communication rules were implemented in order to enable each agent to seek less worked areas of the image. The agents were modeled as Finite-State Machines. Based on the availability of unwrappable pixels, each agent assumed a different state in order to better adapt itself to the surroundings. The implemented rule set was able to fulfill the requirements on reliability and focused unwrapping. The unwrapped phase map was comparable to those from established methods as the agents were able to reliably evaluate each pixel quality. Also, the unwrapping behavior, being observed in real time, was able to focus on workable areas as the agents communicated in order to find less traveled regions. The results were very positive for such a new approach to the phase unwrapping problem. Finally, the authors see great potential for future developments concerning the flexibility, robustness and processing times of the swarm-based algorithm.
High-reliability release mechanism
NASA Technical Reports Server (NTRS)
Paradise, J. J.
1971-01-01
Release mechanism employing simple clevis fitting in combination with two pin-pullers achieves high reliability degree through active mechanical redundancy. Mechanism releases solar arrays. It is simple and inexpensive and performs effectively. It adapts to other release-system applications with variety of pin-puller devices.
Zhang, Yong; Long, Xingning; Ma, Xiaojuan; He, Qianqian; Luo, Xingguang; Bian, Yanhui; Xi, Yuanyuan; Sun, Xia; Ng, Chee H; Vieta, Eduard; Xiang, Yu-Tao
2018-06-05
Bipolar disorder (BD) is often associated with significant functional impairment. However, there is currently no valid and reliable instrument for this variable that is both brief and easy to administer in China. We thus aimed to evaluate the psychometric properties of the Chinese version of the Functioning Assessment Short Test (FAST) in Chinese adults with BD. In this sample of adult subjects, 176 with BD and 53 healthy controls were included. The Chinese version of the FAST, the Young Mania Rating Scale (YMRS), the 17-item Hamilton Depression Rating Scale (HDRS-17) and the Global Assessment Functioning (GAF) were administered, and the psychometric analysis of the FAST was conducted. The internal consistency (Cronbach's alpha) was 0.89 and 0.88 for the FAST at the baseline and week 1, respectively. Four domains (occupational functioning, cognitive functioning, interpersonal relationship and financial issues) at baseline had high item-total correlations. The FAST assessments at baseline and week 1 were highly correlated, indicating high test-retest reliability. The FAST total score was strongly associated with GAF total scores at week 0 (r = -0.952, p < 0.001), HDRS (r = 0.575, p < 0.001) and YRMS (r = 0.394, p < 0.001) and at week 1 (r = -0.945, p < 0.001; r = 0.582, p < 0.001; r = 0.363, p < 0.001), respectively, suggesting high concurrent validity. The FAST showed four dimensional measurement properties in exploratory factor analysis at baseline. The Chinese version of the FAST has satisfactory psychometric properties in terms of validity and reliability in Chinese adults with BD. Copyright © 2018 Elsevier B.V. All rights reserved.
Accelerating evaluation of converged lattice thermal conductivity
NASA Astrophysics Data System (ADS)
Qin, Guangzhao; Hu, Ming
2018-01-01
High-throughput computational materials design is an emerging area in materials science, which is based on the fast evaluation of physical-related properties. The lattice thermal conductivity (κ) is a key property of materials for enormous implications. However, the high-throughput evaluation of κ remains a challenge due to the large resources costs and time-consuming procedures. In this paper, we propose a concise strategy to efficiently accelerate the evaluation process of obtaining accurate and converged κ. The strategy is in the framework of phonon Boltzmann transport equation (BTE) coupled with first-principles calculations. Based on the analysis of harmonic interatomic force constants (IFCs), the large enough cutoff radius (rcutoff), a critical parameter involved in calculating the anharmonic IFCs, can be directly determined to get satisfactory results. Moreover, we find a simple way to largely ( 10 times) accelerate the computations by fast reconstructing the anharmonic IFCs in the convergence test of κ with respect to the rcutof, which finally confirms the chosen rcutoff is appropriate. Two-dimensional graphene and phosphorene along with bulk SnSe are presented to validate our approach, and the long-debate divergence problem of thermal conductivity in low-dimensional systems is studied. The quantitative strategy proposed herein can be a good candidate for fast evaluating the reliable κ and thus provides useful tool for high-throughput materials screening and design with targeted thermal transport properties.
Fast targeted analysis of 132 acidic and neutral drugs and poisons in whole blood using LC-MS/MS.
Di Rago, Matthew; Saar, Eva; Rodda, Luke N; Turfus, Sophie; Kotsos, Alex; Gerostamoulos, Dimitri; Drummer, Olaf H
2014-10-01
The aim of this study was to develop an LC-MS/MS based screening technique that covers a broad range of acidic and neutral drugs and poisons by combining a small sample volume and efficient extraction technique with simple automated data processing. After protein precipitation of 100μL of whole blood, 132 common acidic and neutral drugs and poisons including non-steroidal anti-inflammatory drugs, barbiturates, anticonvulsants, antidiabetics, muscle relaxants, diuretics and superwarfarin rodenticides (47 quantitated, 85 reported as detected) were separated using a Shimadzu Prominence HPLC system with a C18 separation column (Kinetex XB-C18, 4.6mm×150mm, 5μm), using gradient elution with a mobile phase of 25mM ammonium acetate buffer (pH 7.5)/acetonitrile. The drugs were detected using an ABSciex(®) API 2000 LC-MS/MS system (ESI+ and -, MRM mode, two transitions per analyte). The method was fully validated in accordance with international guidelines. Quantification data obtained using one-point calibration compared favorably to that using multiple calibrants. The presented LC-MS/MS assay has proven to be applicable for determination of the analytes in blood. The fast and reliable extraction method combined with automated processing gives the opportunity for high throughput and fast turnaround times for forensic and clinical toxicology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Dhole, Seema M; Khedekar, Pramod B; Amnerkar, Nikhil D
2012-07-01
Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. The developed methods illustrated excellent linearity (r(2) > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations.
Fast Coding of Orientation in Primary Visual Cortex
Shriki, Oren; Kohn, Adam; Shamir, Maoz
2012-01-01
Understanding how populations of neurons encode sensory information is a major goal of systems neuroscience. Attempts to answer this question have focused on responses measured over several hundred milliseconds, a duration much longer than that frequently used by animals to make decisions about the environment. How reliably sensory information is encoded on briefer time scales, and how best to extract this information, is unknown. Although it has been proposed that neuronal response latency provides a major cue for fast decisions in the visual system, this hypothesis has not been tested systematically and in a quantitative manner. Here we use a simple ‘race to threshold’ readout mechanism to quantify the information content of spike time latency of primary visual (V1) cortical cells to stimulus orientation. We find that many V1 cells show pronounced tuning of their spike latency to stimulus orientation and that almost as much information can be extracted from spike latencies as from firing rates measured over much longer durations. To extract this information, stimulus onset must be estimated accurately. We show that the responses of cells with weak tuning of spike latency can provide a reliable onset detector. We find that spike latency information can be pooled from a large neuronal population, provided that the decision threshold is scaled linearly with the population size, yielding a processing time of the order of a few tens of milliseconds. Our results provide a novel mechanism for extracting information from neuronal populations over the very brief time scales in which behavioral judgments must sometimes be made. PMID:22719237
Dhole, Seema M.; Khedekar, Pramod B.; Amnerkar, Nikhil D.
2012-01-01
Background: Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. Objective: UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. Materials and Methods: The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. Results: The developed methods illustrated excellent linearity (r2 > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. Conclusion: The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations. PMID:23781481
solveME: fast and reliable solution of nonlinear ME models.
Yang, Laurence; Ma, Ding; Ebrahim, Ali; Lloyd, Colton J; Saunders, Michael A; Palsson, Bernhard O
2016-09-22
Genome-scale models of metabolism and macromolecular expression (ME) significantly expand the scope and predictive capabilities of constraint-based modeling. ME models present considerable computational challenges: they are much (>30 times) larger than corresponding metabolic reconstructions (M models), are multiscale, and growth maximization is a nonlinear programming (NLP) problem, mainly due to macromolecule dilution constraints. Here, we address these computational challenges. We develop a fast and numerically reliable solution method for growth maximization in ME models using a quad-precision NLP solver (Quad MINOS). Our method was up to 45 % faster than binary search for six significant digits in growth rate. We also develop a fast, quad-precision flux variability analysis that is accelerated (up to 60× speedup) via solver warm-starts. Finally, we employ the tools developed to investigate growth-coupled succinate overproduction, accounting for proteome constraints. Just as genome-scale metabolic reconstructions have become an invaluable tool for computational and systems biologists, we anticipate that these fast and numerically reliable ME solution methods will accelerate the wide-spread adoption of ME models for researchers in these fields.
Wilson, Lydia J; Newhauser, Wayne D
2015-01-01
State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 minutes. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models. PMID:26040833
Jagetic, Lydia J; Newhauser, Wayne D
2015-06-21
State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.
Reliability assessment and improvement for a fast corrector power supply in TPS
NASA Astrophysics Data System (ADS)
Liu, Kuo-Bin; Liu, Chen-Yao; Wang, Bao-Sheng; Wong, Yong Seng
2018-07-01
Fast Orbit Feedback System (FOFB) can be installed in a synchrotron light source to eliminate undesired disturbances and to improve the stability of beam orbit. The design and implementation of an accurate and reliable Fast Corrector Power Supply (FCPS) is essential to realize the effectiveness and availability of the FOFB. A reliability assessment for the FCPSs in the FOFB of Taiwan Photon Source (TPS) considering MOSFETs' temperatures is represented in this paper. The FCPS is composed of a full-bridge topology and a low-pass filter. A Hybrid Pulse Width Modulation (HPWM) requiring two MOSFETs in the full-bridge circuit to be operated at high frequency and the other two be operated at the output frequency is adopted to control the implemented FCPS. Due the characteristic of HPWM, the conduction loss and switching loss of each MOSFET in the FCPS is not same. Two of the MOSFETs in the full-bridge circuit will suffer higher temperatures and therefore the circuit reliability of FCPS is reduced. A Modified PWM Scheme (MPWMS) designed to average MOSFETs' temperatures and to improve circuit reliability is proposed in this paper. Experimental results measure the MOSFETs' temperatures of FCPS controlled by the HPWM and the proposed MPWMS. The reliability indices under different PWM controls are then assessed. From the experimental results, it can be observed that the reliability of FCPS using the proposed MPWMS can be improved because the MOSFETs' temperatures are closer. Since the reliability of FCPS can be enhanced, the availability of FOFB can also be improved.
Hertäg, Loreen; Hass, Joachim; Golovko, Tatiana; Durstewitz, Daniel
2012-01-01
For large-scale network simulations, it is often desirable to have computationally tractable, yet in a defined sense still physiologically valid neuron models. In particular, these models should be able to reproduce physiological measurements, ideally in a predictive sense, and under different input regimes in which neurons may operate in vivo. Here we present an approach to parameter estimation for a simple spiking neuron model mainly based on standard f-I curves obtained from in vitro recordings. Such recordings are routinely obtained in standard protocols and assess a neuron's response under a wide range of mean-input currents. Our fitting procedure makes use of closed-form expressions for the firing rate derived from an approximation to the adaptive exponential integrate-and-fire (AdEx) model. The resulting fitting process is simple and about two orders of magnitude faster compared to methods based on numerical integration of the differential equations. We probe this method on different cell types recorded from rodent prefrontal cortex. After fitting to the f-I current-clamp data, the model cells are tested on completely different sets of recordings obtained by fluctuating ("in vivo-like") input currents. For a wide range of different input regimes, cell types, and cortical layers, the model could predict spike times on these test traces quite accurately within the bounds of physiological reliability, although no information from these distinct test sets was used for model fitting. Further analyses delineated some of the empirical factors constraining model fitting and the model's generalization performance. An even simpler adaptive LIF neuron was also examined in this context. Hence, we have developed a "high-throughput" model fitting procedure which is simple and fast, with good prediction performance, and which relies only on firing rate information and standard physiological data widely and easily available.
Advanced Reactor PSA Methodologies for System Reliability Analysis and Source Term Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, D.; Brunett, A.; Passerini, S.
Beginning in 2015, a project was initiated to update and modernize the probabilistic safety assessment (PSA) of the GE-Hitachi PRISM sodium fast reactor. This project is a collaboration between GE-Hitachi and Argonne National Laboratory (Argonne), and funded in part by the U.S. Department of Energy. Specifically, the role of Argonne is to assess the reliability of passive safety systems, complete a mechanistic source term calculation, and provide component reliability estimates. The assessment of passive system reliability focused on the performance of the Reactor Vessel Auxiliary Cooling System (RVACS) and the inherent reactivity feedback mechanisms of the metal fuel core. Themore » mechanistic source term assessment attempted to provide a sequence specific source term evaluation to quantify offsite consequences. Lastly, the reliability assessment focused on components specific to the sodium fast reactor, including electromagnetic pumps, intermediate heat exchangers, the steam generator, and sodium valves and piping.« less
A Digital Microfluidics Platform for Loop-Mediated Isothermal Amplification Detection
Veigas, Bruno; Águas, Hugo; Fortunato, Elvira; Martins, Rodrigo; Baptista, Pedro Viana; Igreja, Rui
2017-01-01
Digital microfluidics (DMF) arises as the next step in the fast-evolving field of operation platforms for molecular diagnostics. Moreover, isothermal schemes, such as loop-mediated isothermal amplification (LAMP), allow for further simplification of amplification protocols. Integrating DMF with LAMP will be at the core of a new generation of detection devices for effective molecular diagnostics at point-of-care (POC), providing simple, fast, and automated nucleic acid amplification with exceptional integration capabilities. Here, we demonstrate for the first time the role of coupling DMF and LAMP, in a dedicated device that allows straightforward mixing of LAMP reagents and target DNA, as well as optimum temperature control (reaction droplets undergo a temperature variation of just 0.3 °C, for 65 °C at the bottom plate). This device is produced using low-temperature and low-cost production processes, adaptable to disposable and flexible substrates. DMF-LAMP is performed with enhanced sensitivity without compromising reaction efficacy or losing reliability and efficiency, by LAMP-amplifying 0.5 ng/µL of target DNA in just 45 min. Moreover, on-chip LAMP was performed in 1.5 µL, a considerably lower volume than standard bench-top reactions. PMID:29144379
Rebouças, Camila Tavares; Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes
2018-05-18
Background: A green analytical chemistry method was developed for quantification of enrofloxacin in tablets. The drug, a second-generation fluoroquinolone, was first introduced in veterinary medicine for the treatment of various bacterial species. Objective: This study proposed to develop, validate, and apply a reliable, low-cost, fast, and simple IR spectroscopy method for quantitative routine determination of enrofloxacin in tablets. Methods: The method was completely validated according to the International Conference on Harmonisation guidelines, showing accuracy, precision, selectivity, robustness, and linearity. Results: It was linear over the concentration range of 1.0-3.0 mg with correlation coefficients >0.9999 and LOD and LOQ of 0.12 and 0.36 mg, respectively. Conclusions: Now that this IR method has met performance qualifications, it can be adopted and applied for the analysis of enrofloxacin tablets for production process control. The validated method can also be utilized to quantify enrofloxacin in tablets and thus is an environmentally friendly alternative for the routine analysis of enrofloxacin in quality control. Highlights: A new green method for the quantitative analysis of enrofloxacin by Fourier-Transform Infrared spectroscopy was validated. It is a fast, clean and low-cost alternative for the evaluation of enrofloxacin tablets.
Ames, Nancy J; Powers, John H; Ranucci, Alexandra; Gartrell, Kyungsook; Yang, Li; VanRaden, Mark; Leidy, Nancy Kline; Wallen, Gwenyth R
2017-04-27
Although body temperature is one of four key vital signs routinely monitored and treated in clinical practice, relatively little is known about the symptoms associated with febrile states. The purpose of this study was to assess the validity, reliability and feasibility of the Fever Assessment Tool (FAST) in an acute care research setting. Qualitative: To assess content validity and finalize the FAST instrument, 12 adults from an inpatient medical-surgical unit at the National Institutes of Health (NIH) Clinical Center participated in cognitive interviews within approximately 12 h of a febrile state (tympanic temperature ≥ 38° Celsius). Quantitative: To test reliability, validity and feasibility, 56 new adult inpatients completed the 21-item FAST. The cognitive interviews clarified and validated the content of the final 21-item FAST. Fifty-six patients completed the FAST from two to 133 times during routine vital sign assessment, yielding 1,699 temperature time points. Thirty-four percent of the patients (N = 19) experienced fever at one or more time points, with a total of 125 febrile time points. Kuder-Richardson 20 (KR-20) reliability of the FAST was 0.70. Four nonspecific symptom categories, Tired or Run-Down (12), Sleepy (13), Weak or Lacking Energy (11), and Thirsty (9) were among the most frequently reported symptoms in all participants. Using Generalized Estimating Equations (GEE), the odds of reporting eight symptoms, Warm (4), Sweating (5), Thirsty (9), General Body Aches (10), Weak or Lacking Energy (11), Tired or Run Down (12) and Difficulty Breathing (17), were increased when patients had a fever (Fever Now), compared to the two other subgroups-patients who had a fever, but not at that particular time point, (Fever Not Now) and patients who never had a fever (Fever Never). Many, but not all, of the comparisons were significant in both groups. Results suggest the FAST is reliable, valid and easy to administer. In addition to symptoms usually associated with fever (e.g. feeling warm), symptoms such as Difficulty Breathing (17) were identified with fever. Further study in a larger, more diverse patient population is warranted. Clinical Trials Number: NCT01287143 (January 2011).
Rosa, Sarah N.; Oki, Delwyn S.
2010-01-01
Reliable estimates of the magnitude and frequency of floods are necessary for the safe and efficient design of roads, bridges, water-conveyance structures, and flood-control projects and for the management of flood plains and flood-prone areas. StreamStats provides a simple, fast, and reproducible method to define drainage-basin characteristics and estimate the frequency and magnitude of peak discharges in Hawaii?s streams using recently developed regional regression equations. StreamStats allows the user to estimate the magnitude of floods for streams where data from stream-gaging stations do not exist. Existing estimates of the magnitude and frequency of peak discharges in Hawaii can be improved with continued operation of existing stream-gaging stations and installation of additional gaging stations for areas where limited stream-gaging data are available.
Genuine Onion: Simple, Fast, Flexible, and Cheap Website Authentication
2015-05-21
Genuine onion : Simple, Fast, Flexible, and Cheap Website Authentication Paul Syverson U.S. Naval Research Laboratory paul.syverson@nrl.navy.mil...access to Internet websites. Tor is also used to access sites on the . onion virtual domain. The focus of . onion use and discussion has traditionally... onion system can be used to provide an entirely separate benefit: basic website authentication. We also argue that not only can onionsites provide
Constellation Coverage Analysis
NASA Technical Reports Server (NTRS)
Lo, Martin W. (Compiler)
1997-01-01
The design of satellite constellations requires an understanding of the dynamic global coverage provided by the constellations. Even for a small constellation with a simple circular orbit propagator, the combinatorial nature of the analysis frequently renders the problem intractable. Particularly for the initial design phase where the orbital parameters are still fluid and undetermined, the coverage information is crucial to evaluate the performance of the constellation design. We have developed a fast and simple algorithm for determining the global constellation coverage dynamically using image processing techniques. This approach provides a fast, powerful and simple method for the analysis of global constellation coverage.
Specvis: Free and open-source software for visual field examination.
Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna; Waleszczyk, Wioletta J
2017-01-01
Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions).
Specvis: Free and open-source software for visual field examination
Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna
2017-01-01
Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions). PMID:29028825
ERIC Educational Resources Information Center
Thompson, Patricia; Beath, Tricia; Bell, Jacqueline; Jacobson, Gabrielle; Phair, Tegan; Salbach, Nancy M.; Wright, F. Virginia
2008-01-01
Short-term test-retest reliability of the 10-metre fast walk test (10mFWT) and 6-minute walk test (6MWT) was evaluated in 31 ambulatory children with cerebral palsy (CP), with subgroup analyses in Gross Motor Function Classification System (GMFCS) Levels I (n=9), II (n=8), and III (n=14). Sixteen females and 15 males participated, mean age 9 years…
Drew Sayer, R; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W
2016-10-01
The brain's reward system influences ingestive behavior and subsequently obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. This study sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n = 16) and men (n = 12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the two testing days. Mean fasting-state brain responses on day 2 were reduced compared with day 1 in the left insula and right amygdala, but mean day 1 and day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. © 2016 The Obesity Society.
Sayer, R Drew; Tamer, Gregory G; Chen, Ningning; Tregellas, Jason R; Cornier, Marc-Andre; Kareken, David A; Talavage, Thomas M; McCrory, Megan A; Campbell, Wayne W
2016-01-01
Objective The brain’s reward system influences ingestive behavior and subsequently, obesity risk. Functional magnetic resonance imaging (fMRI) is a common method for investigating brain reward function. We sought to assess the reproducibility of fasting-state brain responses to visual food stimuli using BOLD fMRI. Methods A priori brain regions of interest included bilateral insula, amygdala, orbitofrontal cortex, caudate, and putamen. Fasting-state fMRI and appetite assessments were completed by 28 women (n=16) and men (n=12) with overweight or obesity on 2 days. Reproducibility was assessed by comparing mean fasting-state brain responses and measuring test-retest reliability of these responses on the 2 testing days. Results Mean fasting-state brain responses on Day 2 were reduced compared to Day 1 in the left insula and right amygdala, but mean Day 1 and Day 2 responses were not different in the other regions of interest. With the exception of the left orbitofrontal cortex response (fair reliability), test-retest reliabilities of brain responses were poor or unreliable. Conclusion fMRI-measured responses to visual food cues in adults with overweight or obesity show relatively good mean-level reproducibility, but considerable within-subject variability. Poor test-retest reliability reduces the likelihood of observing true correlations and increases the necessary sample sizes for studies. PMID:27542906
2013-01-01
Background The fovea, which is the most sensitive part of the retina, is known to have birefringent properties, i.e. it changes the polarization state of light upon reflection. Existing devices use this property to obtain information on the orientation of the fovea and the direction of gaze. Such devices employ specific frequency components that appear during moments of fixation on a target. To detect them, previous methods have used solely the power spectrum of the Fast Fourier Transform (FFT), which, unfortunately, is an integral method, and does not give information as to where exactly the events of interest occur. With very young patients who are not cooperative enough, this presents a problem, because central fixation may be present only during very short-lasting episodes, and can easily be missed by the FFT. Method This paper presents a method for detecting short-lasting moments of central fixation in existing devices for retinal birefringence scanning, with the goal of a reliable detection of eye alignment. Signal analysis is based on the Continuous Wavelet Transform (CWT), which reliably localizes such events in the time-frequency plane. Even though the characteristic frequencies are not always strongly expressed due to possible artifacts, simple topological analysis of the time-frequency distribution can detect fixation reliably. Results In all six subjects tested, the CWT allowed precise identification of both frequency components. Moreover, in four of these subjects, episodes of intermittent but definitely present central fixation were detectable, similar to those in Figure 4. A simple FFT is likely to treat them as borderline cases, or entirely miss them, depending on the thresholds used. Conclusion Joint time-frequency analysis is a powerful tool in the detection of eye alignment, even in a noisy environment. The method is applicable to similar situations, where short-lasting diagnostic events need to be detected in time series acquired by means of scanning some substrate along a specific path. PMID:23668264
Hardware and software reliability estimation using simulations
NASA Technical Reports Server (NTRS)
Swern, Frederic L.
1994-01-01
The simulation technique is used to explore the validation of both hardware and software. It was concluded that simulation is a viable means for validating both hardware and software and associating a reliability number with each. This is useful in determining the overall probability of system failure of an embedded processor unit, and improving both the code and the hardware where necessary to meet reliability requirements. The methodologies were proved using some simple programs, and simple hardware models.
... Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering the Menu Ordering Your Meal Eating Fast ... A sandwich or burger from a fast food restaurant can contain more than 100 percent of you ...
Neto, Jose Osni Bruggemann; Gesser, Rafael Lehmkuhl; Steglich, Valdir; Bonilauri Ferreira, Ana Paula; Gandhi, Mihir; Vissoci, João Ricardo Nickenig; Pietrobon, Ricardo
2013-01-01
The validation of widely used scales facilitates the comparison across international patient samples. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. The Simple Shoulder Test was translated from English into Brazilian Portuguese, translated back into English, and evaluated for accuracy by an expert committee. It was then administered to 100 patients with shoulder conditions. Psychometric properties were analyzed including factor analysis, internal reliability, test-retest reliability at seven days, and construct validity in relation to the Short Form 36 health survey (SF-36). Factor analysis demonstrated a three factor solution. Cronbach's alpha was 0.82. Test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.84. Associations were observed in the hypothesized direction with all subscales of SF-36 questionnaire. The Simple Shoulder Test translation and cultural adaptation to Brazilian-Portuguese demonstrated adequate factor structure, internal reliability, and validity, ultimately allowing for its use in the comparison with international patient samples.
Neto, Jose Osni Bruggemann; Gesser, Rafael Lehmkuhl; Steglich, Valdir; Bonilauri Ferreira, Ana Paula; Gandhi, Mihir; Vissoci, João Ricardo Nickenig; Pietrobon, Ricardo
2013-01-01
Background The validation of widely used scales facilitates the comparison across international patient samples. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. Objective The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. Methods The Simple Shoulder Test was translated from English into Brazilian Portuguese, translated back into English, and evaluated for accuracy by an expert committee. It was then administered to 100 patients with shoulder conditions. Psychometric properties were analyzed including factor analysis, internal reliability, test-retest reliability at seven days, and construct validity in relation to the Short Form 36 health survey (SF-36). Results Factor analysis demonstrated a three factor solution. Cronbach’s alpha was 0.82. Test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.84. Associations were observed in the hypothesized direction with all subscales of SF-36 questionnaire. Conclusion The Simple Shoulder Test translation and cultural adaptation to Brazilian-Portuguese demonstrated adequate factor structure, internal reliability, and validity, ultimately allowing for its use in the comparison with international patient samples. PMID:23675436
Hybrid learning in signalling games
NASA Astrophysics Data System (ADS)
Barrett, Jeffrey A.; Cochran, Calvin T.; Huttegger, Simon; Fujiwara, Naoki
2017-09-01
Lewis-Skyrms signalling games have been studied under a variety of low-rationality learning dynamics. Reinforcement dynamics are stable but slow and prone to evolving suboptimal signalling conventions. A low-inertia trial-and-error dynamical like win-stay/lose-randomise is fast and reliable at finding perfect signalling conventions but unstable in the context of noise or agent error. Here we consider a low-rationality hybrid of reinforcement and win-stay/lose-randomise learning that exhibits the virtues of both. This hybrid dynamics is reliable, stable and exceptionally fast.
NASA Astrophysics Data System (ADS)
Cavallari, Francesca; de Gruttola, Michele; Di Guida, Salvatore; Govi, Giacomo; Innocente, Vincenzo; Pfeiffer, Andreas; Pierro, Antonio
2011-12-01
Automatic, synchronous and reliable population of the condition databases is critical for the correct operation of the online selection as well as of the offline reconstruction and analysis of data. In this complex infrastructure, monitoring and fast detection of errors is a very challenging task. In this paper, we describe the CMS experiment system to process and populate the Condition Databases and make condition data promptly available both online for the high-level trigger and offline for reconstruction. The data are automatically collected using centralized jobs or are "dropped" by the users in dedicated services (offline and online drop-box), which synchronize them and take care of writing them into the online database. Then they are automatically streamed to the offline database, and thus are immediately accessible offline worldwide. The condition data are managed by different users using a wide range of applications.In normal operation the database monitor is used to provide simple timing information and the history of all transactions for all database accounts, and in the case of faults it is used to return simple error messages and more complete debugging information.
Diffusion blotting: a rapid and simple method for production of multiple blots from a single gel.
Olsen, Ingrid; Wiker, Harald G
2015-01-01
A very simple and fast method for diffusion blotting of proteins from precast SDS-PAGE gels on a solid plastic support was developed. Diffusion blotting for 3 min gives a quantitative transfer of 10 % compared to 1-h electroblotting. For each subsequent blot from the same gel a doubling of transfer time is necessary to obtain the same amount of protein onto each blot. High- and low-molecular-weight components are transferred equally efficiently when compared to electroblotting. However, both methods do give a higher total transfer of the low-molecular-weight proteins compared to the large proteins. The greatest advantage of diffusion blotting is that several blots can be made from each lane, thus enabling testing of multiple antisera on virtually identical blots. The gel remains on the plastic support, which prevents it from stretching or shrinking. This ensures identical blots and facilitates more reliable molecular weight determination. Furthermore the proteins remaining in the gel can be stained with Coomassie Brilliant Blue or other methods for exact and easy comparison with the developed blots. These advantages make diffusion blotting the method of choice when quantitative protein transfer is not required.
... can order a simple blood test , usually done fasting (nothing to eat or drink, except water, for ... screening healthy kids without risk factors, a non-fasting blood test can be used. According to the ...
Lima, Fabricio O; Silva, Gisele S; Furie, Karen L; Frankel, Michael R; Lev, Michael H; Camargo, Érica C S; Haussen, Diogo C; Singhal, Aneesh B; Koroshetz, Walter J; Smith, Wade S; Nogueira, Raul G
2016-08-01
Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. The Field Assessment Stroke Triage for Emergency Destination (FAST-ED) scale was based on items of the National Institutes of Health Stroke Scale (NIHSS) with higher predictive value for LVOS and tested in the Screening Technology and Outcomes Project in Stroke (STOPStroke) cohort, in which patients underwent computed tomographic angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial internal carotid artery, middle cerebral artery-M1, middle cerebral artery-2, or basilar arteries. Patients with partial, bihemispheric, and anterior+posterior circulation occlusions were excluded. Receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value of FAST-ED were compared with the NIHSS, Rapid Arterial Occlusion Evaluation (RACE) scale, and Cincinnati Prehospital Stroke Severity (CPSS) scale. LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the receiver operating characteristic curve: FAST-ED=0.81 as reference; NIHSS=0.80, P=0.28; RACE=0.77, P=0.02; and CPSS=0.75, P=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity of 0.89, positive predictive value of 0.72, and negative predictive value of 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, and 0.79, and CPSS ≥2 of 0.56, 0.85, 0.65, and 0.78, respectively. FAST-ED is a simple scale that if successfully validated in the field, it may be used by medical emergency professionals to identify LVOS in the prehospital setting enabling rapid triage of patients. © 2016 American Heart Association, Inc.
CASTOR: Widely Distributed Scalable Infospaces
2008-11-01
1 i Progress against Planned Objectives Enable nimble apps that react fast as...generation of scalable, reliable, ultra- fast event notification in Linux data centers. • Maelstrom, a spin-off from Ricochet, offers a powerful new option...out potential enhancements to WS-EVENTING and WS-NOTIFICATION based on our work. Potential impact for the warflighter. QSM achieves extremely fast
Zhao, Lian-Hua; Zhao, Hong-Zheng; Zhao, Xue; Kong, Wei-Jun; Hu, Yi-Chen; Yang, Shi-Hai; Yang, Mei-Hua
2016-05-01
Citri Reticulatae Pericarpium (CRP) is a commonly-used traditional Chinese medicine with flavonoids as the major bioactive components. Nevertheless, the contents of the flavonoids in CRP of different sources may significantly vary affecting their therapeutic effects. Thus, the setting up of a reliable and comprehensive quality assessment method for flavonoids in CRP is necessary. To set up a rapid and sensitive ultra-fast liquid chromatography coupled with tandem mass spectrometry (UFLC-MS/MS) method for simultaneous quantification of seven bioactive flavonoids in CRP. A UFLC-MS/MS method coupled to ultrasound-assisted extraction was developed for simultaneous separation and quantification of seven flavonoids including hesperidin, neohesperidin, naringin, narirutin, tangeretin, nobiletin and sinensetin in 16 batches of CRP samples from different sources in China. The established method showed good linearity for all analytes with correlation coefficient (R) over 0.9980, together with satisfactory accuracy, precision and reproducibility. Furthermore, the recoveries at the three spiked levels were higher than 89.71% with relative standard deviations (RSDs) lower than 5.19%. The results indicated that the contents of seven bioactive flavonoids in CRP varied significantly among different sources. Among the samples under study, hesperidin showed the highest contents in 16 samples ranged from 27.50 to 86.30 mg/g, the contents of hesperidin in CRP-15 and CRP-9 were 27.50 and 86.30 mg/g, respectively, while, the amount of narirutin was too low to be measured in some samples. This study revealed that the developed UFLC-MS/MS method was simple, sensitive and reliable for simultaneous quantification of multi-components in CRP with potential perspective for quality control of complex matrices. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Statistical validity of using ratio variables in human kinetics research.
Liu, Yuanlong; Schutz, Robert W
2003-09-01
The purposes of this study were to investigate the validity of the simple ratio and three alternative deflation models and examine how the variation of the numerator and denominator variables affects the reliability of a ratio variable. A simple ratio and three alternative deflation models were fitted to four empirical data sets, and common criteria were applied to determine the best model for deflation. Intraclass correlation was used to examine the component effect on the reliability of a ratio variable. The results indicate that the validity, of a deflation model depends on the statistical characteristics of the particular component variables used, and an optimal deflation model for all ratio variables may not exist. Therefore, it is recommended that different models be fitted to each empirical data set to determine the best deflation model. It was found that the reliability of a simple ratio is affected by the coefficients of variation and the within- and between-trial correlations between the numerator and denominator variables. It was recommended that researchers should compute the reliability of the derived ratio scores and not assume that strong reliabilities in the numerator and denominator measures automatically lead to high reliability in the ratio measures.
Integrated Life-Cycle Framework for Maintenance, Monitoring and Reliability of Naval Ship Structures
2012-08-15
number of times, a fast and accurate method for analyzing the ship hull is required. In order to obtain this required computational speed and accuracy...Naval Engineers Fleet Maintenance & Modernization Symposium (FMMS 2011) [8] and the Eleventh International Conference on Fast Sea Transportation ( FAST ...probabilistic strength of the ship hull. First, a novel deterministic method for the fast and accurate calculation of the strength of the ship hull is
Khalikova, Maria A; Šatínský, Dalibor; Solich, Petr; Nováková, Lucie
2015-05-18
A novel simple, fast and efficient ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed and validated for the separation and quantitative determination of eleven illegal dyes in chili-containing spices. The method involved a simple ultrasound-assisted liquid extraction of illegal compounds with tetrahydrofuran. The separation was performed using a supercritical fluid chromatography system and CSH Fluoro-Phenyl stationary phase at 70°C. The mobile phase was carbon dioxide and the mixture of methanol:acetonitrile (1:1, v/v) with 2.5% formic acid as an additive at the flow rate 2.0 mL min(-1). The UV-vis detection was accomplished at 500 nm for seven compounds and at 420 nm for Sudan Orange G, Butter Yellow, Fast Garnet GBC and Methyl Red due to their maximum of absorbance. All eleven compounds were separated in less than 5 min. The method was successfully validated and applied using three commercial samples of chili-containing spices - Chili sauce (Indonesia), Feferony sauce (Slovakia) and Mojo sauce (Spain). The linearity range of proposed method was 0.50-9.09 mg kg(-1) (r ≥ 0.995). The detection limits were determined as signal to noise ratio of 3 and were ranged from 0.15 mg kg(-1) to 0.60 mg kg(-1) (1.80 mg kg(-1) for Fast Garnet) for standard solution and from 0.25 mg kg(-1) to 1.00 mg kg(-1) (2.50 mg kg(-1) for Fast Garnet, 1.50 mg kg(-1) for Sudan Red 7B) for chili-containing samples. The recovery values were in the range of 73.5-107.2% and relative standard deviation ranging from 0.1% to 8.2% for within-day precision and from 0.5% to 8.8% for between-day precision. The method showed potential for being used to monitor forbidden dyes in food constituents. The developed UHPSFC method was compared to the UHPLC-UV method. The orthogonality of Sudan dyes separation by these two methods was demonstrated. Benefits and drawbacks were discussed showing the reliability of both methods for monitoring of studied illegal dyes in real food constituents. Copyright © 2015 Elsevier B.V. All rights reserved.
Accuracy and speed of material categorization in real-world images.
Sharan, Lavanya; Rosenholtz, Ruth; Adelson, Edward H
2014-08-13
It is easy to visually distinguish a ceramic knife from one made of steel, a leather jacket from one made of denim, and a plush toy from one made of plastic. Most studies of material appearance have focused on the estimation of specific material properties such as albedo or surface gloss, and as a consequence, almost nothing is known about how we recognize material categories like leather or plastic. We have studied judgments of high-level material categories with a diverse set of real-world photographs, and we have shown (Sharan, 2009) that observers can categorize materials reliably and quickly. Performance on our tasks cannot be explained by simple differences in color, surface shape, or texture. Nor can the results be explained by observers merely performing shape-based object recognition. Rather, we argue that fast and accurate material categorization is a distinct, basic ability of the visual system. © 2014 ARVO.
Mora, Leticia; Sentandreu, Miguel Angel; Toldrá, Fidel
2007-06-13
A new HPLC procedure based on hydrophilic interaction chromatography (HILIC) has been developed for the simultaneous determination of carnosine, anserine, balenine, creatine, and creatinine in meat. This is the first time that HILIC has been directly applied to the study of meat components, having the advantage of not requiring complex cleanup and/or sample derivatization procedures. The chromatographic separation has been developed using a silica column (4.6 x 150 mm, 3 microm), and the proposed methodology is simple, reliable, and fast (<13 min per sample). The method has been validated in terms of linearity, repeatability, reproducibility, and recovery and represents an interesting alternative to methods currently in use for determining the mentioned compounds and other polar substances. The detection limits are 5.64, 8.23, 3.66, 3.99, and 0.06 microg/mL for carnosine, anserine, balenine, creatine, and creatinine, respectively.
Simas, Rosineide C; Catharino, Rodrigo R; Cunha, Ildenize B S; Cabral, Elaine C; Barrera-Arellano, Daniel; Eberlin, Marcos N; Alberici, Rosana M
2010-04-01
A fast and reliable method is presented for the analysis of vegetable oils. Easy ambient sonic-spray ionization mass spectrometry (EASI-MS) is shown to efficiently desorb and ionize the main oil constituents from an inert surface under ambient conditions and to provide comprehensive triacylglyceride (TAG) and free fatty acid (FFA) profiles detected mainly as either [TAG + Na](+) or [FFA-H](-) ions. EASI(+/-)-MS analysis is simple, easily implemented, requires just a tiny droplet of the oil and is performed without any pre-separation or chemical manipulation. It also causes no fragmentation of TAG ions hence diacylglyceride (DAG) and monoacylglyceride (MAG) profiles and contents can also be measured. The EASI(+/-)-MS profiles of TAG and FFA permit authentication and quality control and can be used, for instance, to access levels of adulteration, acidity, oxidation or hydrolysis of vegetable oils in general.
Scene-based nonuniformity correction algorithm based on interframe registration.
Zuo, Chao; Chen, Qian; Gu, Guohua; Sui, Xiubao
2011-06-01
In this paper, we present a simple and effective scene-based nonuniformity correction (NUC) method for infrared focal plane arrays based on interframe registration. This method estimates the global translation between two adjacent frames and minimizes the mean square error between the two properly registered images to make any two detectors with the same scene produce the same output value. In this way, the accumulation of the registration error can be avoided and the NUC can be achieved. The advantages of the proposed algorithm lie in its low computational complexity and storage requirements and ability to capture temporal drifts in the nonuniformity parameters. The performance of the proposed technique is thoroughly studied with infrared image sequences with simulated nonuniformity and infrared imagery with real nonuniformity. It shows a significantly fast and reliable fixed-pattern noise reduction and obtains an effective frame-by-frame adaptive estimation of each detector's gain and offset.
Accuracy and speed of material categorization in real-world images
Sharan, Lavanya; Rosenholtz, Ruth; Adelson, Edward H.
2014-01-01
It is easy to visually distinguish a ceramic knife from one made of steel, a leather jacket from one made of denim, and a plush toy from one made of plastic. Most studies of material appearance have focused on the estimation of specific material properties such as albedo or surface gloss, and as a consequence, almost nothing is known about how we recognize material categories like leather or plastic. We have studied judgments of high-level material categories with a diverse set of real-world photographs, and we have shown (Sharan, 2009) that observers can categorize materials reliably and quickly. Performance on our tasks cannot be explained by simple differences in color, surface shape, or texture. Nor can the results be explained by observers merely performing shape-based object recognition. Rather, we argue that fast and accurate material categorization is a distinct, basic ability of the visual system. PMID:25122216
Environmental contamination by lead and cadmium in plants from urban area of Madrid, Spain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, L.M.; Rico, M.C.; Gonzalez, J.
1987-02-01
The monitoring of atmospheric pollution is of great importance. The use of biological materials as metal indicators has been reported to be a relatively cheap, simple and reliable method. Many studies have been made on the influence of air pollution upon plants; however, studies on the relation between metals in airborne particulates and plants are few. Plants are important in the biogeochemical cycle of heavy metals: lead associated with leaves or other deciduous tissue is recycled relatively fast, while lead contained in woody parts of the plant is recycled over a much longer period of time. The aim of thismore » paper is: (a) to determine the lead and cadmium content of the plants investigated; (b) to determine the variations in lead and cadmium in 15 places of the city of Madrid (Spain); (c) to obtain correlations between lead, cadmium, motor traffic, and rain.« less
Three-dimensional surface imaging system for assessing human obesity
NASA Astrophysics Data System (ADS)
Xu, Bugao; Yu, Wurong; Yao, Ming; Pepper, M. Reese; Freeland-Graves, Jeanne H.
2009-10-01
The increasing prevalence of obesity suggests a need to develop a convenient, reliable, and economical tool for assessment of this condition. Three-dimensional (3-D) body surface imaging has emerged as an exciting technology for the estimation of body composition. We present a new 3-D body imaging system, which is designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology is used to satisfy the requirement for a simple hardware setup and fast image acquisition. The portability of the system is created via a two-stand configuration, and the accuracy of body volume measurements is improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3-D body imaging. Body measurement functions dedicated to body composition assessment also are developed. The overall performance of the system is evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.
A 3D surface imaging system for assessing human obesity
NASA Astrophysics Data System (ADS)
Xu, B.; Yu, W.; Yao, M.; Yao, X.; Li, Q.; Pepper, M. R.; Freeland-Graves, J. H.
2009-08-01
The increasing prevalence of obesity suggests a need to develop a convenient, reliable and economical tool for assessment of this condition. Three-dimensional (3D) body surface imaging has emerged as an exciting technology for estimation of body composition. This paper presents a new 3D body imaging system, which was designed for enhanced portability, affordability, and functionality. In this system, stereo vision technology was used to satisfy the requirements for a simple hardware setup and fast image acquisitions. The portability of the system was created via a two-stand configuration, and the accuracy of body volume measurements was improved by customizing stereo matching and surface reconstruction algorithms that target specific problems in 3D body imaging. Body measurement functions dedicated to body composition assessment also were developed. The overall performance of the system was evaluated in human subjects by comparison to other conventional anthropometric methods, as well as air displacement plethysmography, for body fat assessment.
Predicting catalyst-support interactions between metal nanoparticles and amorphous silica supports
NASA Astrophysics Data System (ADS)
Ewing, Christopher S.; Veser, Götz; McCarthy, Joseph J.; Lambrecht, Daniel S.; Johnson, J. Karl
2016-10-01
Metal-support interactions significantly affect the stability and activity of supported catalytic nanoparticles (NPs), yet there is no simple and reliable method for estimating NP-support interactions, especially for amorphous supports. We present an approach for rapid prediction of catalyst-support interactions between Pt NPs and amorphous silica supports for NPs of various sizes and shapes. We use density functional theory calculations of 13 atom Pt clusters on model amorphous silica supports to determine linear correlations relating catalyst properties to NP-support interactions. We show that these correlations can be combined with fast discrete element method simulations to predict adhesion energy and NP net charge for NPs of larger sizes and different shapes. Furthermore, we demonstrate that this approach can be successfully transferred to Pd, Au, Ni, and Fe NPs. This approach can be used to quickly screen stability and net charge transfer and leads to a better fundamental understanding of catalyst-support interactions.
A Novel and Simple Spike Sorting Implementation.
Petrantonakis, Panagiotis C; Poirazi, Panayiota
2017-04-01
Monitoring the activity of multiple, individual neurons that fire spikes in the vicinity of an electrode, namely perform a Spike Sorting (SS) procedure, comprises one of the most important tools for contemporary neuroscience in order to reverse-engineer the brain. As recording electrodes' technology rabidly evolves by integrating thousands of electrodes in a confined spatial setting, the algorithms that are used to monitor individual neurons from recorded signals have to become even more reliable and computationally efficient. In this work, we propose a novel framework of the SS approach in which a single-step processing of the raw (unfiltered) extracellular signal is sufficient for both the detection and sorting of the activity of individual neurons. Despite its simplicity, the proposed approach exhibits comparable performance with state-of-the-art approaches, especially for spike detection in noisy signals, and paves the way for a new family of SS algorithms with the potential for multi-recording, fast, on-chip implementations.
An adaptive tracking observer for failure-detection systems
NASA Technical Reports Server (NTRS)
Sidar, M.
1982-01-01
The design problem of adaptive observers applied to linear, constant and variable parameters, multi-input, multi-output systems, is considered. It is shown that, in order to keep the observer's (or Kalman filter) false-alarm rate (FAR) under a certain specified value, it is necessary to have an acceptable proper matching between the observer (or KF) model and the system parameters. An adaptive observer algorithm is introduced in order to maintain desired system-observer model matching, despite initial mismatching and/or system parameter variations. Only a properly designed adaptive observer is able to detect abrupt changes in the system (actuator, sensor failures, etc.) with adequate reliability and FAR. Conditions for convergence for the adaptive process were obtained, leading to a simple adaptive law (algorithm) with the possibility of an a priori choice of fixed adaptive gains. Simulation results show good tracking performance with small observer output errors and accurate and fast parameter identification, in both deterministic and stochastic cases.
Mandal, Abhishek; Boatz, Jennifer C.; Wheeler, Travis; van der Wel, Patrick C. A.
2017-01-01
A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation. PMID:28229262
Balog, Julia; Perenyi, Dora; Guallar-Hoyas, Cristina; Egri, Attila; Pringle, Steven D; Stead, Sara; Chevallier, Olivier P; Elliott, Chris T; Takats, Zoltan
2016-06-15
Increasingly abundant food fraud cases have brought food authenticity and safety into major focus. This study presents a fast and effective way to identify meat products using rapid evaporative ionization mass spectrometry (REIMS). The experimental setup was demonstrated to be able to record a mass spectrometric profile of meat specimens in a time frame of <5 s. A multivariate statistical algorithm was developed and successfully tested for the identification of animal tissue with different anatomical origin, breed, and species with 100% accuracy at species and 97% accuracy at breed level. Detection of the presence of meat originating from a different species (horse, cattle, and venison) has also been demonstrated with high accuracy using mixed patties with a 5% detection limit. REIMS technology was found to be a promising tool in food safety applications providing a reliable and simple method for the rapid characterization of food products.
Lee, Mi Kyung; Coker, David F
2016-08-18
An accurate approach for computing intermolecular and intrachromophore contributions to spectral densities to describe the electronic-nuclear interactions relevant for modeling excitation energy transfer processes in light harvesting systems is presented. The approach is based on molecular dynamics (MD) calculations of classical correlation functions of long-range contributions to excitation energy fluctuations and a separate harmonic analysis and single-point gradient quantum calculations for electron-intrachromophore vibrational couplings. A simple model is also presented that enables detailed analysis of the shortcomings of standard MD-based excitation energy fluctuation correlation function approaches. The method introduced here avoids these problems, and its reliability is demonstrated in accurate predictions for bacteriochlorophyll molecules in the Fenna-Matthews-Olson pigment-protein complex, where excellent agreement with experimental spectral densities is found. This efficient approach can provide instantaneous spectral densities for treating the influence of fluctuations in environmental dissipation on fast electronic relaxation.
Tinsley, Grant M; Moore, M Lane; Graybeal, Austin J
2018-05-01
Many diets employ regular periods of fasting that extend beyond a typical overnight fast (i.e. intermittent fasting [IF]). Evaluation of acute fasting responses provides information concerning the potential theoretical rationale for IF. The purpose of the present investigation was to assess the test-retest reliability of hunger-related variables during 24-hour fasts and the relationship between these variables and body composition, as well as subsequent energy intake (EI) after fasting. Eleven participants (6 F, 5 M) completed two 24-hour fasts after being provided a 3-day standardized weight-maintenance diet. From 16 to 24 h of fasting, participants were directly observed and provided hourly assessments of hunger, desire to eat (DTE), prospective food consumption (PFC), fullness and energy. After the fast, participants were allowed ad libitum food consumption, and compensation was calculated as EI relative to weight-maintenance energy needs. Test-retest reliability for hunger-related assessments at particular durations of fasting was evaluated using intraclass correlation coefficients (ICC), changes in dependent variables were evaluated using ANOVA with repeated measures, and relationships between variables were explored using bivariate correlations. At 16 h of fasting, the ICCs for all hunger-related assessments were statistically significant (r = 0.67-0.91; p ≤ 0.05). However, as the fast progressed, reliability varied substantially. When averaged across the nine measurements, the ICCs were: 0.81 (fullness), 0.74 (PFC), 0.67 (energy), 0.44 (DTE) and 0.36 (hunger). Body fat percentage was significantly correlated with changes in PFC (r = 0.62, p = 0.04), hunger (r = 0.66, p = 0.03), DTE (r = 0.71, p = 0.02), and fullness (r = -0.63, p = 0.04), but not energy (r = -0.16, p = 0.64). Average EI compensation was only 60% of weight-maintenance needs, but substantial variability was observed (7 to 110% compensation). Compensation was significantly correlated with changes in PFC (r = 0.72, p = 0.01), hunger (r = 0.63, p = 0.04) and DTE (r = 0.60, p = 0.05), but not fullness (r = 0.58, p = 0.06) or energy (r = 0.35, p = 0.29). Compensation and body fat percentage were not correlated (r = 0.03, p = 0.94). The percent of energy intake from fat and protein increased after the fast (29.9 to 37.3% and 13.8 to 16.8%; p < 0.05), while the percent of energy intake from carbohydrate decreased (56.4 to 46.0%; p = 0.02). These results may have implications for IF programs. It is possible that the implementation of multiple "test fasts," in which subjective variables and subsequent energy intake are evaluated, could be used to identify candidates who may be more likely to benefit from an IF program. Copyright © 2018 Elsevier Inc. All rights reserved.
KEYVAN, Ali; GER, Mehmet Can; ERTÜRK, Sevgi Gül; TÜRKCAN, Ahmet
2015-01-01
Introduction The aim of this study was to show the validity and reliability of the M-FAST Turkish Version. Methods Translation and back-translation of the M-FAST was done, then the M-FAST Turkish Version was created with linguistic equivalence. The study was performed with 97 detainees and convicts sent from penal institutions who were internalized at our hospital forensic psychiatry service. M-FAST Turkish Version was applied to evaluees and as a result of clinical interview according to DSM-IV-TR diagnostic criteria and various data explorations the evaluee was examined for malingering. To investigate the internal consistency of the scale, Cronbach’s alpha and test-retest methods were used. In order to check the validity of the scale, in addition to the clinician’s diagnosis, participants were requested to fill the Minnesota Multiphasic Personality Inventory (MMPI) F and K validity scales. Results The mean age of participants was 31.8±9.3 (SD) years. 47 evaluees (48.5%) were diagnosed as malingering. In the internal consistency analysis, Cronbach’s alpha Coefficient was found to be .93. Test-retest relationship that was applied to 22 evaluees was found to be highly significant and strong (r=.89, p<.001). M-FAST scores were significantly high at the malingering group (n=47) (z=−8.02, p<.001). ROC curve analysis suggested a score of ≥7 points as the optimal cut-off for a malingering level for the M-FAST. Kappa coefficients of malingering ± groups were found to be, M-FAST≥7 Kappa: .83; F>16 Kappa: .29; F-K>16 Kappa: .30. For diagnosis of malingering, M-FAST Scale and the MMPI inventory scales were evaluated with the Binary Logistic Regression analysis and only M-FAST scores were found to be significant in prediction of malingering. Conclusion The findings of this study support that, M-FAST Turkish Form represents the structure of the original scale and can be used as a reliable and valid instrument. PMID:28360727
Evaluation of Reliability Coefficients for Two-Level Models via Latent Variable Analysis
ERIC Educational Resources Information Center
Raykov, Tenko; Penev, Spiridon
2010-01-01
A latent variable analysis procedure for evaluation of reliability coefficients for 2-level models is outlined. The method provides point and interval estimates of group means' reliability, overall reliability of means, and conditional reliability. In addition, the approach can be used to test simple hypotheses about these parameters. The…
Defense.gov Special Report: Send Your Vote Home
, is fast approaching. No matter where you are stationed, registering to vote and getting your absentee ballot is simple, fast and easy. State Guidelines Interactive Map Use the State Guidelines Interactive
A reliable, fast and low cost maximum power point tracker for photovoltaic applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enrique, J.M.; Andujar, J.M.; Bohorquez, M.A.
This work presents a new maximum power point tracker system for photovoltaic applications. The developed system is an analog version of the ''P and O-oriented'' algorithm. It maintains its main advantages: simplicity, reliability and easy practical implementation, and avoids its main disadvantages: inaccurateness and relatively slow response. Additionally, the developed system can be implemented in a practical way at a low cost, which means an added value. The system also shows an excellent behavior for very fast variables in incident radiation levels. (author)
Application of the differential decay-curve method to γ-γ fast-timing lifetime measurements
NASA Astrophysics Data System (ADS)
Petkov, P.; Régis, J.-M.; Dewald, A.; Kisyov, S.
2016-10-01
A new procedure for the analysis of delayed-coincidence lifetime experiments focused on the Fast-timing case is proposed following the approach of the Differential decay-curve method. Examples of application of the procedure on experimental data reveal its reliability for lifetimes even in the sub-nanosecond range. The procedure is expected to improve both precision/reliability and treatment of systematic errors and scarce data as well as to provide an option for cross-check with the results obtained by means of other analyzing methods.
A Vertical Organic Transistor Architecture for Fast Nonvolatile Memory.
She, Xiao-Jian; Gustafsson, David; Sirringhaus, Henning
2017-02-01
A new device architecture for fast organic transistor memory is developed, based on a vertical organic transistor configuration incorporating high-performance ambipolar conjugated polymers and unipolar small molecules as the transport layers, to achieve reliable and fast programming and erasing of the threshold voltage shift in less than 200 ns. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Assistant for Specifying Quality Software (ASQS) Mission Area Analysis
1990-12-01
somewhat arbitrary, it was a reasonable and fast approach for partitioning the mission and software domains. The MAD builds on work done by Boeing Aerospace...Reliability ++ Reliability +++ Response 2: NO Discussion: A NO response implies intermittent burns -- most likely to perform attitude control functions...Propulsion Reliability +++ Reliability ++ 4-15 4.8.3 Query BT.3 Query: For intermittent thruster firing requirements, will the average burn time be less than
USDA-ARS?s Scientific Manuscript database
Expressed sequence tag (EST) simple sequence repeats (SSRs) in Prunus were mined, and flanking primers designed and used for genome-wide characterization and selection of primers to optimize marker distribution and reliability. A total of 12,618 contigs were assembled from 84,727 ESTs, along with 34...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Touati, Said; Chennai, Salim; Souli, Aissa
The increased requirements on supervision, control, and performance in modern power systems make power quality monitoring a common practise for utilities. Large databases are created and automatic processing of the data is required for fast and effective use of the available information. Aim of the work presented in this paper is the development of tools for analysis of monitoring power quality data and in particular measurements of voltage and currents in various level of electrical power distribution. The study is extended to evaluate the reliability of the electrical system in nuclear plant. Power Quality is a measure of how wellmore » a system supports reliable operation of its loads. A power disturbance or event can involve voltage, current, or frequency. Power disturbances can originate in consumer power systems, consumer loads, or the utility. The effect of power quality problems is the loss power supply leading to severe damage to equipments. So, we try to track and improve system reliability. The assessment can be focused on the study of impact of short circuits on the system, harmonics distortion, power factor improvement and effects of transient disturbances on the Electrical System during motor starting and power system fault conditions. We focus also on the review of the Electrical System design against the Nuclear Directorate Safety Assessment principles, including those extended during the last Fukushima nuclear accident. The simplified configuration of the required system can be extended from this simple scheme. To achieve these studies, we have used a demo ETAP power station software for several simulations. (authors)« less
Rozen, Warren Matthew; Spychal, Robert T.; Hunter-Smith, David J.
2016-01-01
Background Accurate volumetric analysis is an essential component of preoperative planning in both reconstructive and aesthetic breast procedures towards achieving symmetrization and patient-satisfactory outcome. Numerous comparative studies and reviews of individual techniques have been reported. However, a unifying review of all techniques comparing their accuracy, reliability, and practicality has been lacking. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE, was undertaken. Results Since Bouman’s first description of water displacement method, a range of volumetric assessment techniques have been described: thermoplastic casting, direct anthropomorphic measurement, two-dimensional (2D) imaging, and computed tomography (CT)/magnetic resonance imaging (MRI) scans. However, most have been unreliable, difficult to execute and demonstrate limited practicability. Introduction of 3D surface imaging has revolutionized the field due to its ease of use, fast speed, accuracy, and reliability. However, its widespread use has been limited by its high cost and lack of high level of evidence. Recent developments have unveiled the first web-based 3D surface imaging program, 4D imaging, and 3D printing. Conclusions Despite its importance, an accurate, reliable, and simple breast volumetric analysis tool has been elusive until the introduction of 3D surface imaging technology. However, its high cost has limited its wide usage. Novel adjunct technologies, such as web-based 3D surface imaging program, 4D imaging, and 3D printing, appear promising. PMID:27047788
Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples.
Daems, Devin; van Nuijs, Alexander L N; Covaci, Adrian; Hamidi-Asl, Ezat; Van Camp, Guy; Nagels, Luc J
2015-07-01
The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright © 2014 John Wiley & Sons, Ltd.
Sabokrou, Mohammad; Fayyaz, Mohsen; Fathy, Mahmood; Klette, Reinhard
2017-02-17
This paper proposes a fast and reliable method for anomaly detection and localization in video data showing crowded scenes. Time-efficient anomaly localization is an ongoing challenge and subject of this paper. We propose a cubicpatch- based method, characterised by a cascade of classifiers, which makes use of an advanced feature-learning approach. Our cascade of classifiers has two main stages. First, a light but deep 3D auto-encoder is used for early identification of "many" normal cubic patches. This deep network operates on small cubic patches as being the first stage, before carefully resizing remaining candidates of interest, and evaluating those at the second stage using a more complex and deeper 3D convolutional neural network (CNN). We divide the deep autoencoder and the CNN into multiple sub-stages which operate as cascaded classifiers. Shallow layers of the cascaded deep networks (designed as Gaussian classifiers, acting as weak single-class classifiers) detect "simple" normal patches such as background patches, and more complex normal patches are detected at deeper layers. It is shown that the proposed novel technique (a cascade of two cascaded classifiers) performs comparable to current top-performing detection and localization methods on standard benchmarks, but outperforms those in general with respect to required computation time.
Ma, R; Castellanos, D C; Bachman, J
2016-07-01
China is in the midst of the nutrition transition with increasing rates of obesity and dietary changes. One contributor is the increase in fast food chains within the country. The purpose of this study was to develop a theory-based instrument that explores influencing factors of fast food consumption in adolescents residing in Beijing, China. Cross-sectional study. Value expectancy and theory of planned behaviour were utilised to explore influencing factors of fast food consumption in the target population. There were 201 Chinese adolescents between the ages of 12 and 18. Cronbach's alpha correlation coefficients were used to examine internal reliability of the theory-based questionnaire. Bivariate correlations and a MANOVA were utilised to determine the relationship between theory-based constructs, body mass index (BMI)-for-age and fast food intake frequency as well as to determine differences in theory-based scores among fast food consumption frequency groupings. The theory-based questionnaire showed good reliability. Furthermore, there was a significant difference in the theory-based subcategory scores between fast food frequency groups. A significant positive correlation was observed between times per week fast food was consumed and each theory-based subscale score. Using BMI-for-age of 176 participants, 81% were normal weight and 19% were considered overweight or obese. Results showed consumption of fast food to be on average 1.50 ± 1.33 per week. The relationship between BMI-for-age and times per week fast food was consumed was not significant. As the nutrition transition continues and fast food chains expand, it is important to explore factors effecting fast food consumption in China. Interventions targeting influencing factors can be developed to encourage healthy dietary choice in the midst of this transition. Copyright © 2016. Published by Elsevier Ltd.
Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish
Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan
2015-01-01
Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.
Xu, Chonggang; Gertner, George
2013-01-01
Fourier Amplitude Sensitivity Test (FAST) is one of the most popular uncertainty and sensitivity analysis techniques. It uses a periodic sampling approach and a Fourier transformation to decompose the variance of a model output into partial variances contributed by different model parameters. Until now, the FAST analysis is mainly confined to the estimation of partial variances contributed by the main effects of model parameters, but does not allow for those contributed by specific interactions among parameters. In this paper, we theoretically show that FAST analysis can be used to estimate partial variances contributed by both main effects and interaction effects of model parameters using different sampling approaches (i.e., traditional search-curve based sampling, simple random sampling and random balance design sampling). We also analytically calculate the potential errors and biases in the estimation of partial variances. Hypothesis tests are constructed to reduce the effect of sampling errors on the estimation of partial variances. Our results show that compared to simple random sampling and random balance design sampling, sensitivity indices (ratios of partial variances to variance of a specific model output) estimated by search-curve based sampling generally have higher precision but larger underestimations. Compared to simple random sampling, random balance design sampling generally provides higher estimation precision for partial variances contributed by the main effects of parameters. The theoretical derivation of partial variances contributed by higher-order interactions and the calculation of their corresponding estimation errors in different sampling schemes can help us better understand the FAST method and provide a fundamental basis for FAST applications and further improvements. PMID:24143037
Xu, Chonggang; Gertner, George
2011-01-01
Fourier Amplitude Sensitivity Test (FAST) is one of the most popular uncertainty and sensitivity analysis techniques. It uses a periodic sampling approach and a Fourier transformation to decompose the variance of a model output into partial variances contributed by different model parameters. Until now, the FAST analysis is mainly confined to the estimation of partial variances contributed by the main effects of model parameters, but does not allow for those contributed by specific interactions among parameters. In this paper, we theoretically show that FAST analysis can be used to estimate partial variances contributed by both main effects and interaction effects of model parameters using different sampling approaches (i.e., traditional search-curve based sampling, simple random sampling and random balance design sampling). We also analytically calculate the potential errors and biases in the estimation of partial variances. Hypothesis tests are constructed to reduce the effect of sampling errors on the estimation of partial variances. Our results show that compared to simple random sampling and random balance design sampling, sensitivity indices (ratios of partial variances to variance of a specific model output) estimated by search-curve based sampling generally have higher precision but larger underestimations. Compared to simple random sampling, random balance design sampling generally provides higher estimation precision for partial variances contributed by the main effects of parameters. The theoretical derivation of partial variances contributed by higher-order interactions and the calculation of their corresponding estimation errors in different sampling schemes can help us better understand the FAST method and provide a fundamental basis for FAST applications and further improvements.
Wide dynamic logarithmic InGaAs sensor suitable for eye-safe active imaging
NASA Astrophysics Data System (ADS)
Ni, Yang; Bouvier, Christian; Arion, Bogdan; Noguier, Vincent
2016-05-01
In this paper, we present a simple method to analyze the injection efficiency of the photodiode interface circuit under fast shuttering conditions for active Imaging applications. This simple model has been inspired from the companion model for reactive elements largely used in CAD. In this paper, we demonstrate that traditional CTIA photodiode interface is not adequate for active imaging where fast and precise shuttering operation is necessary. Afterwards we present a direct amplification based photodiode interface which can provide an accurate and fast shuttering operation on photodiode. These considerations have been used in NIT's newly developed ROIC and corresponding SWIR sensors both in VGA 15um pitch (NSC1201) and also in QVGA 25um pitch (NSC1401).
Zager, Valerija; Cemazar, Maja; Hreljac, Irena; Lah, Tamara T; Sersa, Gregor; Filipic, Metka
2010-03-01
Human exposure to genotoxic agents in the environment and everyday life represents a serious health threat. Fast and reliable assessment of genotoxicity of chemicals is of main importance in the fields of new chemicals and drug development as well as in environmental monitoring. The tumor suppressor gene p21, the major downstream target gene of activated p53 which is responsible for cell cycle arrest following DNA damage, has been shown to be specifically up-regulated by genotoxic carcinogens. The aim of our study was to develop a human cell-based biosensor system for simple and fast detection of genotoxic agents. Metabolically active HepG2 human hepatoma cells were transfected with plasmid encoding Enhanced Green Fluorescent Protein (EGFP) under the control of the p21 promoter (p21HepG2GFP). DNA damage was induced by genotoxic agents with known mechanisms of action. The increase in fluorescence intensity, due to p21 mediated EGFP expression, was measured with a fluorescence microplate reader. The viability of treated cells was determined by the colorimetric MTS assay. The directly acting alkylating agent methylmethane sulphonate (MMS) showed significant increase in EGFP production after 48 h at 20 μg/mL. The indirectly acting carcinogen benzo(a)pyren (BaP) and the cross-linking agent cisplatin (CisPt) induced a dose- dependent increase in EGFP fluorescence, which was already significant at concentrations 0.13 μg/mL and 0.41 μg/mL, respectively. Vinblastine (VLB), a spindle poison that does not induce direct DNA damage, induced only a small increase in EGFP fluorescence intensity after 24 h at the lowest concentration (0.1 μg/mL), while exposure to higher concentrations was associated with significantly reduced cell viability. The results of our study demonstrated that this novel assay based on the stably transformed cell line p21HepG2GFP can be used as a fast and simple biosensor system for detection of genetic damage caused by chemical agents.
Operator Priming and Generalization of Practice in Adults' Simple Arithmetic
ERIC Educational Resources Information Center
Chen, Yalin; Campbell, Jamie I. D.
2016-01-01
There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication,…
No Generalization of Practice for Nonzero Simple Addition
ERIC Educational Resources Information Center
Campbell, Jamie I. D.; Beech, Leah C.
2014-01-01
Several types of converging evidence have suggested recently that skilled adults solve very simple addition problems (e.g., 2 + 1, 4 + 2) using a fast, unconscious counting algorithm. These results stand in opposition to the long-held assumption in the cognitive arithmetic literature that such simple addition problems normally are solved by fact…
The Data Evaluation for Obtaining Accuracy and Reliability
NASA Astrophysics Data System (ADS)
Kim, Chang Geun; Chae, Kyun Shik; Lee, Sang Tae; Bhang, Gun Woong
2012-11-01
Nemours scientific measurement results are flooded from the paper, data book, etc. as fast growing of internet. We meet many different measurement results on the same measurand. In this moment, we are face to choose most reliable one out of them. But it is not easy to choose and use the accurate and reliable data as we do at an ice cream parlor. Even expert users feel difficult to distinguish the accurate and reliable scientific data from huge amount of measurement results. For this reason, the data evaluation is getting more important as the fast growing of internet and globalization. Furthermore the expressions of measurement results are not in standardi-zation. As these need, the international movement has been enhanced. At the first step, the global harmonization of terminology used in metrology and the expression of uncertainty in measurement were published in ISO. These methods are wide spread to many area of science on their measurement to obtain the accuracy and reliability. In this paper, it is introduced that the GUM, SRD and data evaluation on atomic collisions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moriarty, Tom
The NREL cell measurement lab measures the IV parameters of cells of multiple sizes and configurations. A large contributing factor to errors and uncertainty in Jsc, Imax, Pmax and efficiency can be the irradiance spatial nonuniformity. Correcting for this nonuniformity through its precise and frequent measurement can be very time consuming. This paper explains a simple, fast and effective method based on bicubic interpolation for determining and correcting for spatial nonuniformity and verification of the method's efficacy.
Sass, J O; Endres, W
1997-08-01
Much evidence supports the hypothesis that mild or moderate hyperhomocysteinaemia represents an important and independent risk factor for occlusive vascular diseases. Therefore, the accurate and reliable determination of total plasma homocysteine has gained major importance for risk assessment. Furthermore, it can help in the detection of folate and vitamin B12 deficiency. This has prompted us to develop a sensitive gas chromatography-mass spectrometry (GC-MS) method in order to quantify total homocysteine in human plasma. Prior to chromatography, reduced homocysteine was released from disulfide bonds by incubation with excess dithiothreitol and converted into its N(O,S)-propoxycarbonyl propyl ester by derivatization with n-propyl chloroformate. Aminoethylcysteine served as internal standard. The method proved to be highly linear over the entire concentration range examined (corresponding to 0-266 microM homocysteine) and showed intra-assay and inter-assay variation (relative standard deviations) of approximately 5 and 5-10%, respectively. External quality control by comparison with duplicate analysis performed on a HPLC-based system revealed satisfactory correlation. The newly developed GC-MS based method provides simple, reliable and fast quantification of total homocysteine and requires only inexpensive chemicals, which are easy to obtain.
Electrical Characterization of Semiconductor Materials and Devices
NASA Astrophysics Data System (ADS)
Deen, M.; Pascal, Fabien
Semiconductor materials and devices continue to occupy a preeminent technological position due to their importance when building integrated electronic systems used in a wide range of applications from computers, cell-phones, personal digital assistants, digital cameras and electronic entertainment systems, to electronic instrumentation for medical diagnositics and environmental monitoring. Key ingredients of this technological dominance have been the rapid advances made in the quality and processing of materials - semiconductors, conductors and dielectrics - which have given metal oxide semiconductor device technology its important characteristics of negligible standby power dissipation, good input-output isolation, surface potential control and reliable operation. However, when assessing material quality and device reliability, it is important to have fast, nondestructive, accurate and easy-to-use electrical characterization techniques available, so that important parameters such as carrier doping density, type and mobility of carriers, interface quality, oxide trap density, semiconductor bulk defect density, contact and other parasitic resistances and oxide electrical integrity can be determined. This chapter describes some of the more widely employed and popular techniques that are used to determine these important parameters. The techniques presented in this chapter range in both complexity and test structure requirements from simple current-voltage measurements to more sophisticated low-frequency noise, charge pumping and deep-level transient spectroscopy techniques.
Development of a non-explosive release actuator using shape memory alloy wire.
Yoo, Young Ik; Jeong, Ju Won; Lim, Jae Hyuk; Kim, Kyung-Won; Hwang, Do-Soon; Lee, Jung Ju
2013-01-01
We have developed a newly designed non-explosive release actuator that can replace currently used release devices. The release mechanism is based on a separation mechanism, which relies on segmented nuts and a shape memory alloy (SMA) wire trigger. A quite fast and simple trigger operation is made possible through the use of SMA wire. This actuator is designed to allow a high preload with low levels of shock for the solar arrays of medium-size satellites. After actuation, the proposed device can be easily and instantly reset. Neither replacement, nor refurbishment of any components is necessary. According to the results of a performance test, the release time, preload capacity, and maximum shock level are 50 ms, 15 kN, and 350 G, respectively. In order to increase the reliability of the actuator, more than ten sets of performance tests are conducted. In addition, the proposed release actuator is tested under thermal vacuum and extreme vibration environments. No degradation or damage was observed during the two environment tests, and the release actuator was able to operate successfully. Considering the test results as a whole, we conclude that the proposed non-explosive release actuator can be applied reliably to intermediate-size satellites to replace existing release systems.
Laser-Induced Breakdown Spectroscopy Based Protein Assay for Cereal Samples.
Sezer, Banu; Bilge, Gonca; Boyaci, Ismail Hakki
2016-12-14
Protein content is an important quality parameter in terms of price, nutritional value, and labeling of various cereal samples. However, conventional analysis methods, namely, Kjeldahl and Dumas, have major drawbacks such as long analysis time, titration mistakes, and carrier gas dependence with high purity. For this reason, there is an urgent need for rapid, reliable, and environmentally friendly technologies for protein analysis. The present study aims to develop a new method for protein analysis in wheat flour and whole meal by using laser-induced breakdown spectroscopy (LIBS), which is a multielemental, fast, and simple spectroscopic method. Unlike the Kjeldahl and Dumas methods, it has potential to analyze a high number of samples in considerably short time. In the study, nitrogen peaks in LIBS spectra of wheat flour and whole meal samples with different protein contents were correlated with results of the standard Dumas method with the aid of chemometric methods. A calibration graph showed good linearity with the protein content between 7.9 and 20.9% and a 0.992 coefficient of determination (R 2 ). The limit of detection was calculated as 0.26%. The results indicated that LIBS is a promising and reliable method with its high sensitivity for routine protein analysis in wheat flour and whole meal samples.
Fast gas spectroscopy using pulsed quantum cascade lasers
NASA Astrophysics Data System (ADS)
Beyer, T.; Braun, M.; Lambrecht, A.
2003-03-01
Laser spectroscopy has found many industrial applications, e.g., control of automotive exhaust and process monitoring. The midinfrared region is of special interest because it has stronger absorption lines compared to the near infrared (NIR). However, in the NIR high quality reliable laser sources, detectors, and passive optical components are available. A quantum cascade laser could change this situation if fundamental advantages can be exploited with compact and reliable systems. It will be shown that, using pulsed lasers and available fast detectors, lower residual sensitivity levels than in corresponding NIR systems can be achieved. The stability is sufficient for industrial applications.
Junker, Laura V; Ensminger, Ingo
2016-12-01
Rapid developments in remote-sensing of vegetation and high-throughput precision plant phenotyping promise a range of real-life applications using leaf optical properties for non-destructive assessment of plant performance. Use of leaf optical properties for assessing plant performance requires the ability to use photosynthetic pigments as proxies for physiological properties and the ability to detect these pigments fast, reliably and at low cost. We describe a simple and cost-effective protocol for the rapid analysis of chlorophylls, carotenoids and tocopherols using high-performance liquid chromatography (HPLC). Many existing methods are based on the expensive solvent acetonitrile, take a long time or do not include lutein epoxide and α-carotene. We aimed to develop an HPLC method which separates all major chlorophylls and carotenoids as well as lutein epoxide, α-carotene and α-tocopherol. Using a C 30 -column and a mobile phase with a gradient of methanol, methyl-tert-butyl-ether (MTBE) and water, our method separates the above pigments and isoprenoids within 28 min. The broad applicability of our method is demonstrated using samples from various plant species and tissue types, e.g. leaves of Arabidopsis and avocado plants, several deciduous and conifer tree species, various crops, stems of parasitic dodder, fruit of tomato, roots of carrots and Chlorella algae. In comparison to previous methods, our method is very affordable, fast and versatile and can be used to analyze all major photosynthetic pigments that contribute to changes in leaf optical properties and which are of interest in most ecophysiological studies. © 2016 Scandinavian Plant Physiology Society.
de Diego, Antonio M G
2010-02-01
The ability of adrenal chromaffin cells to fast-release catecholamines relies on their capacity to fire action potentials (APs). However, little attention has been paid to the requirements needed to evoke the controlled firing of APs. Few data are available in rodents and none on the bovine chromaffin cell, a model extensively used by researchers. The aim of this work was to clarify this issue. Short puffs of acetylcholine (ACh) were fast perifused to current-clamped chromaffin cells and produced the firing of single APs. Based on the currents generated by such ACh applications and previous literature, current waveforms that efficiently elicited APs at frequencies up to 20 Hz were generated. Complex waveforms were also generated by adding simple waveforms with different delays; these waveforms aimed at modeling the stimulation patterns that a chromaffin cell would conceivably undergo upon strong synaptic stimulation. Cholinergic innervation was assessed using the acetylcholinesterase staining technique on the supposition that the innervation pattern is a determinant of the kind of stimuli chromaffin cells can receive. It is concluded that 1) a reliable method to produce frequency-controlled APs by applying defined current injection waveforms is achieved; 2) the APs thus generated have essentially the same features as those spontaneously emitted by the cell and those elicited by fast-ACh perifusion; 3) the higher frequencies attainable peak at around 30 Hz; and 4) the bovine adrenal medulla shows abundant cholinergic innervation, and chromaffin cells show strong acetylcholinesterase staining, consistent with a tight cholinergic presynaptic control of firing frequency.
On the nature of fast sausage waves in coronal loops
NASA Astrophysics Data System (ADS)
Bahari, Karam
2018-05-01
The effect of the parameters of coronal loops on the nature of fast sausage waves are investigated. To do this three models of the coronal loop considered, a simple loop model, a current-carrying loop model and a model with radially structured density called "Inner μ" profile. For all the models the Magnetohydrodynamic (MHD) equations solved analytically in the linear approximation and the restoring forces of oscillations obtained. The ratio of the magnetic tension force to the pressure gradient force obtained as a function of the distance from the axis of the loop. In the simple loop model for all values of the loop parameters the fast sausages wave have a mixed nature of Alfvénic and fast MHD waves, in the current-carrying loop model with thick annulus and low density contrast the fast sausage waves can be considered as purely Alfvénic wave in the core region of the loop, and in the "Inner μ" profile for each set of the parameters of the loop the wave can be considered as a purely Alfvénic wave in some regions of the loop.
Foust, Amanda; Popovic, Marko; Zecevic, Dejan; McCormick, David A.
2010-01-01
Purkinje neurons are the output cells of the cerebellar cortex and generate spikes in two distinct modes, known as simple and complex spikes. Revealing the point of origin of these action potentials, and how they conduct into local axon collaterals, is important for understanding local and distal neuronal processing and communication. By utilizing a recent improvement in voltage sensitive dye imaging technique that provided exceptional spatial and temporal resolution, we were able to resolve the region of spike initiation as well as follow spike propagation into axon collaterals for each action potential initiated on single trials. All fast action potentials, for both simple and complex spikes, whether occurring spontaneously or in response to a somatic current pulse or synaptic input, initiated in the axon initial segment. At discharge frequencies of less than approximately 250 Hz, spikes propagated faithfully through the axon and axon collaterals, in a saltatory manner. Propagation failures were only observed for very high frequencies or for the spikelets associated with complex spikes. These results demonstrate that the axon initial segment is a critical decision point in Purkinje cell processing and that the properties of axon branch points are adjusted to maintain faithful transmission. PMID:20484631
Shrivas, Kamlesh; Wu, Hui-Fen
2007-11-02
A simple and rapid sample cleanup and preconcentration method for the quantitative determination of caffeine in one drop of beverages and foods by gas chromatography/mass spectrometry (GC/MS) has been proposed using drop-to-drop solvent microextraction (DDSME). The best optimum experimental conditions for DDSME were: chloroform as the extraction solvent, 5 min extraction time, 0.5 microL exposure volume of the extraction phase and no salt addition at room temperature. The optimized methodology exhibited good linearity between 0.05 and 5.0 microg/mL with correlation coefficient of 0.980. The relative standard deviation (RSD) and limits of detection (LOD) of the DDSME/GC/MS method were 4.4% and 4.0 ng/mL, respectively. Relative recovery of caffeine in beverages and foods were found to be 96.6-101%, which showing good reliability of this method. This DDSME excludes the major disadvantages of conventional method of caffeine extraction, like large amount of organic solvent and sample consumption and long sample pre-treatment process. So, this approach proves that the DDSME/GC/MS technique can be applied as a simple, fast and feasible diagnosis tool for environmental, food and biological application for extremely small amount of real sample analysis.
A stable and convenient protein electrophoresis titration device with bubble removing system.
Zhang, Qiang; Fan, Liu-Yin; Li, Wen-Lin; Cong, Feng-Song; Zhong, Ran; Chen, Jing-Jing; He, Yu-Chen; Xiao, Hua; Cao, Cheng-Xi
2017-07-01
Moving reaction boundary titration (MRBT) has a potential application to immunoassay and protein content analysis with high selectivity. However, air bubbles often impair the accuracy of MRBT, and the leakage of electrolyte greatly decreases the safety and convenience of electrophoretic titration. Addressing these two issues a reliable MRBT device with modified electrolyte chamber of protein titration was designed. Multiphysics computer simulation was conducted for optimization according to two-phase flow. The single chamber was made of two perpendicular cylinders with different diameters. After placing electrophoretic tube, the resident air in the junction next to the gel could be eliminated by a simple fast electrolyte flow. Removing the electrophoretic tube automatically prevented electrolyte leakage at the junction due to the gravity-induced negative pressure within the chamber. Moreover, the numerical simulation and experiments showed that the improved MRBT device has following advantages: (i) easy and rapid setup of electrophoretic tube within 20 s; (ii) simple and quick bubble dissipates from the chamber of titration within 2 s; (iii) no electrolyte leakage from the two chambers: and (iv) accurate protein titration and safe instrumental operation. The developed technique and apparatus greatly improves the performance of the previous MRBT device, and providing a new route toward practical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A study on gaseous extinguishing agent sensing with a simple measurement method
NASA Astrophysics Data System (ADS)
Guan, Yu; Lu, Song; Yuan, Wei; Qian, Hanjie
2018-03-01
As research on the concentration distribution for evaluating the effectiveness of a gas fire extinguisher system is quite important, the proper sensing technology is necessary. Here, a simple method used for measuring the concentration of agent is introduced, and the manufacture of the sensing part is described clearly. The sensing unit is composed of a pressure reducing structure and pressure sensor element. The detection was achieved by sensing the change of pressure difference caused by gas flow. In order to verify the theory and characterize the sensing performance, two types of fire extinguishing agents, bromotrifluoromethane (CBrF3) and heptafluoropropane (C3HF7), were used in the experiments. The results showed a high sensitivity from 0 to 100%, good repeatability and fast response/recovery time. Furthermore, the effect of operating temperature, humidity and geometric structure on the response were investigated. Measurements showed, for CBrF3, that the temperature had a linear impact on the response and the influence of humidity in the sensor was negligible. Through the analysis of the geometry parameter, it was found that the sensing performance could be greatly improved through adjusting the geometry structure. This technique provides a low-cost and highly reliable sensor for the detection of gaseous extinguishing agent that can be easily fabricated.
A novel method for determining sex in late term gestational mice based on the external genitalia
Murdaugh, Laura B.; Mendoza-Romero, Haley N.; Fish, Eric W.
2018-01-01
In many experiments using fetal mice, it is necessary to determine the sex of the individual fetus. However, other than genotyping for sex-specific genes, there is no convenient, reliable method of sexing mice between gestational day (GD) 16.5 and GD 18.0. We designed a rapid, relatively simple visual method to determine the sex of mouse fetuses in the GD 16.5—GD 18.0 range that can be performed as part of a routine morphological assessment. By examining the genitalia for the presence or absence of key features, raters with minimal experience with the method were able to correctly identify the sex of embryos with 99% accuracy, while raters with no experience were 95% accurate. The critical genital features include: the presence or absence of urethral seam or proximal urethral meatus; the shape of the genitalia, and the presence or absence of an area related to the urethral plate. By comparing these morphological features of the external genitalia, we show a simple, accurate, and fast way to determine the sex of late stage mouse fetuses. Integrating this method into regular morphological assessments will facilitate the determination of sex differences in fetuses between GD 16.5 and GD 18.0. PMID:29617407
FAITH – Fast Assembly Inhibitor Test for HIV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague
Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less
Computing Reliabilities Of Ceramic Components Subject To Fracture
NASA Technical Reports Server (NTRS)
Nemeth, N. N.; Gyekenyesi, J. P.; Manderscheid, J. M.
1992-01-01
CARES calculates fast-fracture reliability or failure probability of macroscopically isotropic ceramic components. Program uses results from commercial structural-analysis program (MSC/NASTRAN or ANSYS) to evaluate reliability of component in presence of inherent surface- and/or volume-type flaws. Computes measure of reliability by use of finite-element mathematical model applicable to multiple materials in sense model made function of statistical characterizations of many ceramic materials. Reliability analysis uses element stress, temperature, area, and volume outputs, obtained from two-dimensional shell and three-dimensional solid isoparametric or axisymmetric finite elements. Written in FORTRAN 77.
Hu, Hua; Jonas, Peter
2014-01-01
Fast-spiking, parvalbumin-expressing GABAergic interneurons/basket cells (BCs) play a key role in feedforward and feedback inhibition, gamma oscillations, and complex information processing. For these functions, fast propagation of action potentials (APs) from the soma to the presynaptic terminals is important. However, the functional properties of interneuron axons remain elusive. Here, we examined interneuron axons by confocally targeted subcellular patch-clamp recording in rat hippocampal slices. APs were initiated in the proximal axon ~20 μm from the soma, and propagated to the distal axon with high reliability and speed. Subcellular mapping revealed a stepwise increase of Na+ conductance density from the soma to the proximal axon, followed by a further gradual increase in the distal axon. Active cable modeling and experiments with partial channel block indicated that low axonal Na+ conductance density was sufficient for reliability, but high Na+ density was necessary for both speed of propagation and fast-spiking AP phenotype. Our results suggest that a supercritical density of Na+ channels compensates for the morphological properties of interneuron axons (small segmental diameter, extensive branching, and high bouton density), ensuring fast AP propagation and high-frequency repetitive firing. PMID:24657965
Minimum Control Requirements for Advanced Life Support Systems
NASA Technical Reports Server (NTRS)
Boulange, Richard; Jones, Harry; Jones, Harry
2002-01-01
Advanced control technologies are not necessary for the safe, reliable and continuous operation of Advanced Life Support (ALS) systems. ALS systems can and are adequately controlled by simple, reliable, low-level methodologies and algorithms. The automation provided by advanced control technologies is claimed to decrease system mass and necessary crew time by reducing buffer size and minimizing crew involvement. In truth, these approaches increase control system complexity without clearly demonstrating an increase in reliability across the ALS system. Unless these systems are as reliable as the hardware they control, there is no savings to be had. A baseline ALS system is presented with the minimal control system required for its continuous safe reliable operation. This baseline control system uses simple algorithms and scheduling methodologies and relies on human intervention only in the event of failure of the redundant backup equipment. This ALS system architecture is designed for reliable operation, with minimal components and minimal control system complexity. The fundamental design precept followed is "If it isn't there, it can't fail".
Reliability Standards of Complex Engineering Systems
NASA Astrophysics Data System (ADS)
Galperin, E. M.; Zayko, V. A.; Gorshkalev, P. A.
2017-11-01
Production and manufacture play an important role in today’s modern society. Industrial production is nowadays characterized by increased and complex communications between its parts. The problem of preventing accidents in a large industrial enterprise becomes especially relevant. In these circumstances, the reliability of enterprise functioning is of particular importance. Potential damage caused by an accident at such enterprise may lead to substantial material losses and, in some cases, can even cause a loss of human lives. That is why industrial enterprise functioning reliability is immensely important. In terms of their reliability, industrial facilities (objects) are divided into simple and complex. Simple objects are characterized by only two conditions: operable and non-operable. A complex object exists in more than two conditions. The main characteristic here is the stability of its operation. This paper develops the reliability indicator combining the set theory methodology and a state space method. Both are widely used to analyze dynamically developing probability processes. The research also introduces a set of reliability indicators for complex technical systems.
De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip
2017-01-01
Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL.
The new ATLAS Fast Calorimeter Simulation
NASA Astrophysics Data System (ADS)
Schaarschmidt, J.; ATLAS Collaboration
2017-10-01
Current and future need for large scale simulated samples motivate the development of reliable fast simulation techniques. The new Fast Calorimeter Simulation is an improved parameterized response of single particles in the ATLAS calorimeter that aims to accurately emulate the key features of the detailed calorimeter response as simulated with Geant4, yet approximately ten times faster. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. A prototype of this new Fast Calorimeter Simulation is in development and its integration into the ATLAS simulation infrastructure is ongoing.
Pont, Frédéric; Fournié, Jean Jacques
2010-03-01
MS, the reference technology for proteomics, routinely produces large numbers of protein lists whose fast comparison would prove very useful. Unfortunately, most softwares only allow comparisons of two to three lists at once. We introduce here nwCompare, a simple tool for n-way comparison of several protein lists without any query language, and exemplify its use with differential and shared cancer cell proteomes. As the software compares character strings, it can be applied to any type of data mining, such as genomic or metabolomic datalists.
RF-MEMS capacitive switches with high reliability
Goldsmith, Charles L.; Auciello, Orlando H.; Carlisle, John A.; Sampath, Suresh; Sumant, Anirudha V.; Carpick, Robert W.; Hwang, James; Mancini, Derrick C.; Gudeman, Chris
2013-09-03
A reliable long life RF-MEMS capacitive switch is provided with a dielectric layer comprising a "fast discharge diamond dielectric layer" and enabling rapid switch recovery, dielectric layer charging and discharging that is efficient and effective to enable RF-MEMS switch operation to greater than or equal to 100 billion cycles.
Coding for reliable satellite communications
NASA Technical Reports Server (NTRS)
Lin, S.
1984-01-01
Several error control coding techniques for reliable satellite communications were investigated to find algorithms for fast decoding of Reed-Solomon codes in terms of dual basis. The decoding of the (255,223) Reed-Solomon code, which is used as the outer code in the concatenated TDRSS decoder, was of particular concern.
Rigamonti, A E; Bini, S; Grugni, G; Agosti, F; De Col, A; Mallone, M; Cella, S G; Sartorio, A
2014-10-01
The effect of eating rate on the release of anorexigenic gut peptides in Prader-Willi syndrome (PWS), a neurogenetic disorder clinically characterized by hyperphagia and excessive obesity, has not been investigated so far. Postprandial PYY and GLP-1 levels to fast (5 min) and slow (30 min) ice cream consumption were measured in PWS adult patients and age-matched patients with simple obesity and normal-weighted subjects. Visual analog scales (VASs) were used to evaluate the subjective feelings of hunger and satiety. Fast ice cream consumption stimulated GLP-1 release in normal subjects, a greater increase being observed with slow feeding. Fast or slow feeding did not change circulating levels of GLP-1 in obese patients, while, unexpectedly, fast feeding (but not slow feeding) stimulated GLP-1 release in PWS patients. Plasma PYY concentrations increased in all groups, irrespective of the eating rate. Slow feeding was more effective in stimulating PYY release in normal subjects, while fast feeding was more effective in PWS patients. Slow feeding evoked a lower hunger and higher satiety compared with fast feeding in normal subjects, this finding being not evident in obese patients. Unexpectedly, fast feeding evoked a lower hunger and higher satiety in PWS patients in comparison with slow feeding. Fast feeding leads to higher concentrations of anorexigenic gut peptides and favours satiety in PWS adult patients, this pattern being not evident in age-matched patients with simple obesity, thus suggesting the existence of a different pathophysiological substrate in these two clinical conditions. © 2013 John Wiley & Sons Ltd.
Camp, Christopher L; Heidenreich, Mark J; Dahm, Diane L; Bond, Jeffrey R; Collins, Mark S; Krych, Aaron J
2016-03-01
Tibial tubercle-trochlear groove (TT-TG) distance is a variable that helps guide surgical decision-making in patients with patellar instability. The purpose of this study was to compare the accuracy and reliability of an MRI TT-TG measuring technique using a simple external alignment method to a previously validated gold standard technique that requires advanced software read by radiologists. TT-TG was calculated by MRI on 59 knees with a clinical diagnosis of patellar instability in a blinded and randomized fashion by two musculoskeletal radiologists using advanced software and by two orthopaedists using the study technique which utilizes measurements taken on a simple electronic imaging platform. Interrater reliability between the two radiologists and the two orthopaedists and intermethods reliability between the two techniques were calculated using interclass correlation coefficients (ICC) and concordance correlation coefficients (CCC). ICC and CCC values greater than 0.75 were considered to represent excellent agreement. The mean TT-TG distance was 14.7 mm (Standard Deviation (SD) 4.87 mm) and 15.4 mm (SD 5.41) as measured by the radiologists and orthopaedists, respectively. Excellent interobserver agreement was noted between the radiologists (ICC 0.941; CCC 0.941), the orthopaedists (ICC 0.978; CCC 0.976), and the two techniques (ICC 0.941; CCC 0.933). The simple TT-TG distance measurement technique analysed in this study resulted in excellent agreement and reliability as compared to the gold standard technique. This method can predictably be performed by orthopaedic surgeons without advanced radiologic software. II.
Parastar, Hadi; Mostafapour, Sara; Azimi, Gholamhasan
2016-01-01
Comprehensive two-dimensional gas chromatography and flame ionization detection combined with unfolded-partial least squares is proposed as a simple, fast and reliable method to assess the quality of gasoline and to detect its potential adulterants. The data for the calibration set are first baseline corrected using a two-dimensional asymmetric least squares algorithm. The number of significant partial least squares components to build the model is determined using the minimum value of root-mean square error of leave-one out cross validation, which was 4. In this regard, blends of gasoline with kerosene, white spirit and paint thinner as frequently used adulterants are used to make calibration samples. Appropriate statistical parameters of regression coefficient of 0.996-0.998, root-mean square error of prediction of 0.005-0.010 and relative error of prediction of 1.54-3.82% for the calibration set show the reliability of the developed method. In addition, the developed method is externally validated with three samples in validation set (with a relative error of prediction below 10.0%). Finally, to test the applicability of the proposed strategy for the analysis of real samples, five real gasoline samples collected from gas stations are used for this purpose and the gasoline proportions were in range of 70-85%. Also, the relative standard deviations were below 8.5% for different samples in the prediction set. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Feng, Shangguo; Zhu, Yujia; Yu, Chenliang; Jiao, Kaili; Jiang, Mengying; Lu, Jiangjie; Shen, Chenjia; Ying, Qicai; Wang, Huizhong
2018-01-01
Physalis is an important genus in the Solanaceae family. It includes many species of significant medicinal value, edible value, and ornamental value. However, many Physalis species are easily confused because of their similar morphological traits, which hinder the utilization and protection of Physalis resources. Therefore, it is necessary to create fast, sensitive, and reliable methods for the Physalis species authentication. Intended for that, in this study, species-specific sequence-characterized amplified region (SCAR) markers were developed for accurate identification of the closely related Physalis species P. angulata, P. minima, P. pubescens, and P. alkekengi var. franchetii, based on a simple and novel marker system, start codon targeted (SCoT) marker. A total of 34 selected SCoT primers yielded 289 reliable SCoT loci, of which 265 were polymorphic. Four species-specific SCoT fragments (SCoT3-1404, SCoT3-1589, SCoT5-550, and SCoT36-520) from Physalis species were successfully identified, cloned, and sequenced. Based on these selected specific DNA fragments, four SCAR primers pairs were developed and named ST3KZ, ST3MSJ, ST5SJ, and ST36XSJ. PCR analysis of each of these primer pairs clearly demonstrated a specific amplified band in all samples of the target Physalis species, but no amplification was observed in other Physalis species. Therefore, the species-specific SCAR primer pairs developed in this study could be used as powerful tools that can rapidly, effectively, and reliably identify and differentiate Physalis species.
ERIC Educational Resources Information Center
Smith, Stacey L.; Vannest, Kimberly J.; Davis, John L.
2011-01-01
The reliability of data is a critical issue in decision-making for practitioners in the school. Percent Agreement and Cohen's kappa are the two most widely reported indices of inter-rater reliability, however, a recent Monte Carlo study on the reliability of multi-category scales found other indices to be more trustworthy given the type of data…
O'Connor, S; McCaffrey, N; Whyte, E; Moran, K
2016-07-01
To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.
FAST: a framework for simulation and analysis of large-scale protein-silicon biosensor circuits.
Gu, Ming; Chakrabartty, Shantanu
2013-08-01
This paper presents a computer aided design (CAD) framework for verification and reliability analysis of protein-silicon hybrid circuits used in biosensors. It is envisioned that similar to integrated circuit (IC) CAD design tools, the proposed framework will be useful for system level optimization of biosensors and for discovery of new sensing modalities without resorting to laborious fabrication and experimental procedures. The framework referred to as FAST analyzes protein-based circuits by solving inverse problems involving stochastic functional elements that admit non-linear relationships between different circuit variables. In this regard, FAST uses a factor-graph netlist as a user interface and solving the inverse problem entails passing messages/signals between the internal nodes of the netlist. Stochastic analysis techniques like density evolution are used to understand the dynamics of the circuit and estimate the reliability of the solution. As an example, we present a complete design flow using FAST for synthesis, analysis and verification of our previously reported conductometric immunoassay that uses antibody-based circuits to implement forward error-correction (FEC).
Peptide-gated ion channels and the simple nervous system of Hydra.
Gründer, Stefan; Assmann, Marc
2015-02-15
Neurons either use electrical or chemical synapses to communicate with each other. Transmitters at chemical synapses are either small molecules or neuropeptides. After binding to their receptors, transmitters elicit postsynaptic potentials, which can either be fast and transient or slow and longer lasting, depending on the type of receptor. Fast transient potentials are mediated by ionotropic receptors and slow long-lasting potentials by metabotropic receptors. Transmitters and receptors are well studied for animals with a complex nervous system such as vertebrates and insects, but much less is known for animals with a simple nervous system like Cnidaria. As cnidarians arose early in animal evolution, nervous systems might have first evolved within this group and the study of neurotransmission in cnidarians might reveal an ancient mechanism of neuronal communication. The simple nervous system of the cnidarian Hydra extensively uses neuropeptides and, recently, we cloned and functionally characterized an ion channel that is directly activated by neuropeptides of the Hydra nervous system. These results demonstrate the existence of peptide-gated ion channels in Hydra, suggesting they mediate fast transmission in its nervous system. As related channels are also present in the genomes of the cnidarian Nematostella, of placozoans and of ctenophores, it should be considered that the early nervous systems of cnidarians and ctenophores have co-opted neuropeptides for fast transmission at chemical synapses. © 2015. Published by The Company of Biologists Ltd.
Decay Time of Cathodoluminescence
ERIC Educational Resources Information Center
Kraftmakher, Yaakov
2009-01-01
Simple measurements of the decay time of cathodoluminescence are described. Cathodoluminescence is used in many devices, including computer monitors, oscilloscopes, radar displays and television tubes. The experimental setup is simple and easy to build. Two oscilloscopes, a function generator, and a fast photodiode are needed for the experiments.…
Development and evaluation of the nurse quality of communication with patient questionnaire.
Vuković, Mira; Gvozdenović, Branislav S; Stamatović-Gajić, Branka; Ilić, Miodrag; Gajić, Tomislav
2010-01-01
Nurse/patient relationship as a complex interrelation or as an interaction of the factor patient and factor nurse has been a subject of a number of studies during the past ten years. Nurse/patient communication is a special entity, usually observed within a framework of the wider nurse/patient relationship. In that regard, we wanted to develop a standardized questionnaire that could reliably measure the quality of communication between nurse and patient, and be used by nurses. The main goal of this study was to develop and evaluate construct validity of the Nurse Quality of Communication with Patient Questionnaire (NQCPQ), as well as to evaluate its reliability. The goal was also to establish a measure of inter-raters reliability, using two repeated measurements of results by items and scores of the NQCPQ, on the same observed units by two assessors. The starting NQCPQ that consists of 25 items, was filled in by two groups of nurses. Each nurse was questioned during morning and afternoon shifts, in order to evaluate their communication with hospitalized patients, using marks from 1 to 6. To evaluate construct validity, we used the analysis of main components, while reliability was assessed using intraclass correlation coefficient and Cronbach-alpha coefficient. To evaluate interraters reliability, we used Pearson correlation coefficient. Using a group of 118 patients, we explained 86% of the unknown, regarding the investigated phenomenon (communication nurse/patient), using one component by which we separated 6 items of the questionnaire. Inter-item correlation (alpha) in this component was 0.96. Pearson correlation coefficient was highly significant, value 0.7 by item, and correlation coefficient for scores at repeated measurements was 0.84. NQCPQ is 6-item instrument with high construct validity. It can be used to measure quality of nurse/patient communication in a simple, fast and reliable way. It could contribute to more adequate research and defining of this problem, and as such could be used in studies of interaction of psychometric, clinical, biochemical, socio-cultural, demographic and other parameters as well.
Pallapothu, Leela Mohan Kumar; Batta, Neelima; Pigili, Ravi Kumar; Yejella, Rajendra Prasad
2015-02-01
A simple, rapid and sensitive analytical method using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) detection with positive ion electrospray ionization was developed for the determination of dienogest in human K2 EDTA plasma using levonorgestrel d6 as an internal standard (IS). Dienogest and IS were extracted from human plasma using simple liquid-liquid extraction. Chromatographic separation was achieved on a Zorbax XDB-Phenyl column (4.6 × 75 mm, 3.5 µm) under isocratic conditions using acetonitrile-5 mm ammonium acetate (70:30, v/v) at a flow rate of 0.60 mL/min. The protonated precursor to product ion transitions monitored for dienogest and IS were at m/z 312.30 → 135.30 and 319.00 → 251.30, respectively. The method was validated with a linearity range of 1.003-200.896 ng/mL having a total analysis time for each chromatograph of 3.0 min. The method has shown tremendous reproducibility with intra- and inter-day precision (coefficient of variation) <3.97 and 6.10%, respectively, and accuracy within ±4.0% of nominal values. The validated method was applied to a pharmacokinetic study in human plasma samples generated after administration of a single oral dose of 2.0 mg dienogest tablets to healthy female volunteers and was proved to be highly reliable for the analysis of clinical samples. Copyright © 2014 John Wiley & Sons, Ltd.
Biomonitoring of selenoprotein P in human serum by fast affinity chromatography coupled to ICP-MS.
Heitland, Peter; Köster, Helmut D
2018-04-01
Most of the Se in human serum is bound to selenoprotein P (SEPP1) in which Se is present in form of selenocysteine. The SEPP1 is a new possible biomarker for the Se status and for this reason we developed a fast, simple and reliable method for the quantitative determination of SEPP1 in serum by affinity chromatography coupled to ICP-MS. It is possible to separate SEPP1 from other selenoproteins in serum in only 5 min, which allows high sample throughput in clinical laboratories. Measured and certified concentrations of total Se and Se(SEPP1) are in good agreement for the reference material SRM 1950. The SEPP1 concentration was stable in serum samples of 3 persons for a minimum of 2 weeks. Further results of method validation were described including internal and external quality assurance. The analytical method was applied for a biomonitoring study of the SEPP1 and total Se concentration in human serum of 50 occupationally non-exposed persons living in northern Germany. Concentration ranges and mean concentrations for Se(SEPP1) are 31.1-59.7 and 46.2 μg/L, respectively. The corresponding values for total Se are 62-120 and 83.5 μg/L. The mean percentage of total Se in serum present as SEPP1 is 58%. Copyright © 2018 Elsevier GmbH. All rights reserved.
Highly Coarse-Grained Representations of Transmembrane Proteins
2017-01-01
Numerous biomolecules and biomolecular complexes, including transmembrane proteins (TMPs), are symmetric or at least have approximate symmetries. Highly coarse-grained models of such biomolecules, aiming at capturing the essential structural and dynamical properties on resolution levels coarser than the residue scale, must preserve the underlying symmetry. However, making these models obey the correct physics is in general not straightforward, especially at the highly coarse-grained resolution where multiple (∼3–30 in the current study) amino acid residues are represented by a single coarse-grained site. In this paper, we propose a simple and fast method of coarse-graining TMPs obeying this condition. The procedure involves partitioning transmembrane domains into contiguous segments of equal length along the primary sequence. For the coarsest (lowest-resolution) mappings, it turns out to be most important to satisfy the symmetry in a coarse-grained model. As the resolution is increased to capture more detail, however, it becomes gradually more important to match modular repeats in the secondary structure (such as helix-loop repeats) instead. A set of eight TMPs of various complexity, functionality, structural topology, and internal symmetry, representing different classes of TMPs (ion channels, transporters, receptors, adhesion, and invasion proteins), has been examined. The present approach can be generalized to other systems possessing exact or approximate symmetry, allowing for reliable and fast creation of multiscale, highly coarse-grained mappings of large biomolecular assemblies. PMID:28043122
Yilmaz, B.; Kaban, S.; Akcay, B. K.
2015-01-01
In this study, simple, fast and reliable cyclic voltammetry, linear sweep voltammetry, square wave voltammetry and differential pulse voltammetry methods were developed and validated for determination of etodolac in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of etodolac at platinum electrode in acetonitrile solution containing 0.1 M lithium perchlorate. The well-defined oxidation peak was observed at 1.03 V. The calibration curves were linear for etodolac at the concentration range of 2.5-50 μg/ml for linear sweep, square wave and differential pulse voltammetry methods, respectively. Intra- and inter-day precision values for etodolac were less than 4.69, and accuracy (relative error) was better than 2.00%. The mean recovery of etodolac was 100.6% for pharmaceutical preparations. No interference was found from three tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Etol, Tadolak and Etodin tablets as pharmaceutical preparation. PMID:26664057
[Perineal reconstruction: Salvage surgery with 2flaps technique].
Jiménez Gómez, Marta; Navarro-Sánchez, Antonio; Lima Sánchez, Jaime; Hernández Hernández, Juan Ramón
2017-12-01
The principles of perineal reconstructive surgery comprise adequate filling of the defect along with stable and durable skin coverage, with a low morbidity rate. Two-flap perineal reconstruction is a simple, fast and reliable technique that uses a single donor site. This improves scar position with low morbidity. It is based in the use of 2flaps; one flap fills the defect with a «turn over» technique and the other is a rotation - advancement flap for skin coverage. A 52-year-old male diagnosed with Lynch syndrome who underwent laparoscopic abdominoperineal amputation for adenocarcinoma of the lower rectum and developed recurrence 2years later over the perineal scar that required radical resection and perineal reconstruction. The use of this approach facilitates perineal reconstruction and enables treatment of patients with large and complex defects in frequently irradiated tissues where wound dehiscence and infection are common. Copyright © 2017 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Kanaujia, Pankaj K; Pardasani, Deepak; Gupta, A K; Dubey, D K
2007-01-19
Efficient extraction of chemical warfare agents (CWAs) from water is essential before subjecting them to gas chromatographic and spectral analysis aiming towards verification of the Chemical Weapons Convention (CWC). It requires development of fast, reliable, simple and reproducible sample preparation of CWAs from water which is likely to be contaminated during deliberate or inadvertent spread of CWAs. This work describes development of a solid-phase extraction method using hydrophilic-lipophilic balance (HLB) cartridges for extraction of CWAs from water. The extraction efficiencies of HLB and C18 cartridges were compared and the results revealed that HLB sorbents performed better. Extracts were analyzed by gas chromatography-mass spectrometry. Extraction parameters, such as extraction solvent, its volume and rinsing solvent were optimized. Best recoveries of target analytes were obtained using 1mL methanol and limits of detection were achieved up to 0.05microg/mL with dichloromethane. Precision of the method was found to be less than 9.2% RSD.
Intelligent Gate Drive for Fast Switching and Crosstalk Suppression of SiC Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Zheyu; Dix, Jeffery; Wang, Fei Fred
This study presents an intelligent gate drive for silicon carbide (SiC) devices to fully utilize their potential of high switching-speed capability in a phase-leg configuration. Based on the SiC device's intrinsic properties, a gate assist circuit consisting of two auxiliary transistors with two diodes is introduced to actively control gate voltages and gate loop impedances of both devices in a phase-leg configuration during different switching transients. Compared to conventional gate drives, the proposed circuit has the capability of accelerating the switching speed of the phase-leg power devices and suppressing the crosstalk to below device limits. Based on Wolfspeed 1200-V SiCmore » MOSFETs, the test results demonstrate the effectiveness of this intelligent gate drive under varying operating conditions. More importantly, the proposed intelligent gate assist circuitry is embedded into a gate drive integrated circuit, offering a simple, compact, and reliable solution for end-users to maximize benefits of SiC devices in actual power electronics applications.« less
Intelligent Gate Drive for Fast Switching and Crosstalk Suppression of SiC Devices
Zhang, Zheyu; Dix, Jeffery; Wang, Fei Fred; ...
2017-01-19
This study presents an intelligent gate drive for silicon carbide (SiC) devices to fully utilize their potential of high switching-speed capability in a phase-leg configuration. Based on the SiC device's intrinsic properties, a gate assist circuit consisting of two auxiliary transistors with two diodes is introduced to actively control gate voltages and gate loop impedances of both devices in a phase-leg configuration during different switching transients. Compared to conventional gate drives, the proposed circuit has the capability of accelerating the switching speed of the phase-leg power devices and suppressing the crosstalk to below device limits. Based on Wolfspeed 1200-V SiCmore » MOSFETs, the test results demonstrate the effectiveness of this intelligent gate drive under varying operating conditions. More importantly, the proposed intelligent gate assist circuitry is embedded into a gate drive integrated circuit, offering a simple, compact, and reliable solution for end-users to maximize benefits of SiC devices in actual power electronics applications.« less
CMOS Cell Sensors for Point-of-Care Diagnostics
Adiguzel, Yekbun; Kulah, Haluk
2012-01-01
The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies. PMID:23112587
CMOS cell sensors for point-of-care diagnostics.
Adiguzel, Yekbun; Kulah, Haluk
2012-01-01
The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies.
NASA Astrophysics Data System (ADS)
Chen, Yufeng; Yang, Jin; Li, Zonglong; Li, Ran; Ruan, Weidong; Zhuang, Zhiping; Zhao, Bing
2016-01-01
Raman spectroscopy, surface-enhanced Raman spectroscopy (SERS) and density functional theory (DFT) simulations were employed to study 5-amino-2-mercaptobenzimidazole (5-A-2MBI) molecules. Ag colloids were used as SERS substrates which were prepared by using hydroxylamine hydrochloride as reducing agent. Raman vibration modes and SERS characteristic peaks of 5-A-2MBI were assigned with the aid of DFT calculations. The molecular electrostatic potential (MEP) of 5-A-2MBI was used to discuss the possible adsorption behavior of 5-A-2MBI on Ag colloids. The spectral analysis showed that 5-A-2MBI molecules were slightly titled via the sulfur atoms adhering to the surfaces of Ag substrates. The obtained SERS spectral intensity decreased when lowering the 5-A-2MBI concentrations. A final detection limit on the concentration of 5 × 10- 7 mol · L- 1 was gained. SERS proved to be a simple, fast and reliable method for the detection and characterization of 5-A-2MBI molecules.
Fast and Accurate Circuit Design Automation through Hierarchical Model Switching.
Huynh, Linh; Tagkopoulos, Ilias
2015-08-21
In computer-aided biological design, the trifecta of characterized part libraries, accurate models and optimal design parameters is crucial for producing reliable designs. As the number of parts and model complexity increase, however, it becomes exponentially more difficult for any optimization method to search the solution space, hence creating a trade-off that hampers efficient design. To address this issue, we present a hierarchical computer-aided design architecture that uses a two-step approach for biological design. First, a simple model of low computational complexity is used to predict circuit behavior and assess candidate circuit branches through branch-and-bound methods. Then, a complex, nonlinear circuit model is used for a fine-grained search of the reduced solution space, thus achieving more accurate results. Evaluation with a benchmark of 11 circuits and a library of 102 experimental designs with known characterization parameters demonstrates a speed-up of 3 orders of magnitude when compared to other design methods that provide optimality guarantees.
Physical and chemical characterization of petroleum products by GC-MS.
Mendez, A; Meneghini, R; Lubkowitz, J
2007-01-01
There is a need for reliable and fast means of monitoring refining, conversion, and upgrading processes aiming to increase the yield of light distillates, and thus, reducing the oil barrel bottoms. By simultaneously utilizing the FID and mass selective detectors while splitting the column effluent in a controlled way, it is possible to obtain identical gas chromatograms and total ion chromatograms from a single run. This means that besides the intensity vs. time graphs, the intensity vs. mass and boiling point can also be obtained. As a result, physical and chemical characterization can be performed in a simple and rapid manner. Experimental results on middle, heavy distillates, and crude oil fractions show clearly the effect of upgrading processes on the chemical composition and yields of diesel, jet fuels, and high vacuum gasoil fractions. The methodology is fully compliant with ASTM D-2887, D-7213, D-6352, and D7169 for simulated distillation and the previously mentioned mass spectrometry standards. The group type analysis correlated satisfactorily with high-performance liquid chromatography data.
Fluidic Vectoring of a Planar Incompressible Jet Flow
NASA Astrophysics Data System (ADS)
Mendez, Miguel Alfonso; Scelzo, Maria Teresa; Enache, Adriana; Buchlin, Jean-Marie
2018-06-01
This paper presents an experimental, a numerical and a theoretical analysis of the performances of a fluidic vectoring device for controlling the direction of a turbulent, bi-dimensional and low Mach number (incompressible) jet flow. The investigated design is the co-flow secondary injection with Coanda surface, which allows for vectoring angles up to 25° with no need of moving mechanical parts. A simple empirical model of the vectoring process is presented and validated via experimental and numerical data. The experiments consist of flow visualization and image processing for the automatic detection of the jet centerline; the numerical simulations are carried out solving the Unsteady Reynolds Average Navier- Stokes (URANS) closed with the k - ω SST turbulence model, using the PisoFoam solver from OpenFOAM. The experimental validation on three different geometrical configurations has shown that the model is capable of providing a fast and reliable evaluation of the device performance as a function of the operating conditions.
Yaman, Yesim Tugce; Abaci, Serdar
2016-01-01
A novel electrochemical sensor gold nanoparticle (AuNP)/polyvinylpyrrolidone (PVP) modified pencil graphite electrode (PGE) was developed for the ultrasensitive determination of Bisphenol A (BPA). The gold nanoparticles were electrodeposited by constant potential electrolysis and PVP was attached by passive adsorption onto the electrode surface. The electrode surfaces were characterized by electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The parameters that affected the experimental conditions were researched and optimized. The AuNP/PVP/PGE sensor provided high sensitivity and selectivity for BPA recognition by using square wave adsorptive stripping voltammetry (SWAdSV). Under optimized conditions, the detection limit was found to be 1.0 nM. This new sensor system offered the advantages of simple fabrication which aided the expeditious replication, low cost, fast response, high sensitivity and low background current for BPA. This new sensor system was successfully tested for the detection of the amount of BPA in bottled drinking water with high reliability. PMID:27231912
Zafra-Gómez, Alberto; Garballo, Antonio; Morales, Juan C; García-Ayuso, Luis E
2006-06-28
A fast, simple, and reliable method for the isolation and determination of the vitamins thiamin, riboflavin, niacin, pantothenic acid, pyridoxine, folic acid, cyanocobalamin, and ascorbic acid in food samples is proposed. The most relevant advantages of the proposed method are the simultaneous determination of the eight more common vitamins in enriched food products and a reduction of the time required for quantitative extraction, because the method consists merely of the addition of a precipitation solution and centrifugation of the sample. Furthermore, this method saves a substantial amount of reagents as compared with official methods, and minimal sample manipulation is achieved due to the few steps required. The chromatographic separation is carried out on a reverse phase C18 column, and the vitamins are detected at different wavelengths by either fluorescence or UV-visible detection. The proposed method was applied to the determination of water-soluble vitamins in supplemented milk, infant nutrition products, and milk powder certified reference material (CRM 421, BCR) with recoveries ranging from 90 to 100%.
Colorimetric detection of copper in water using a Schiff base derivative
NASA Astrophysics Data System (ADS)
Peralta Domínguez, D.; Ramos-Ortiz, G.; Maldonado, J. L.; Rodriguez, M.; Meneses-Nava, M. A.; Barbosa-Garcia, O.; Santillan, R.; Farfán, N.
2013-09-01
Organic molecular sensors have the advantage of being used through an easy, fast, economical and reliable optical method for detecting toxic metal ions in our environment. In this work, we present a simple but highly specific organic ligand compound 5-Chloro-2-((E)-((E)-3-(4-(dimethylamino)phenyl)allylidene)amino)phenol (L1) that acts as a colorimetric sensor for ions in a mixture of acetonitrile/water (ratio 10:1, v:v). Binding interaction between L1 and various metal-ions has been established by ultraviolet-visible spectroscopic measurements that indicate favorable coordination of the ligand with selective metal ions, particularly, with copper. These results showed that the electronic transition band shape of L1 change after binding with copper in aqueous solution. L1 exhibited binding-induced color changes from yellow to pink one detected by the naked eye. This new sensor presented 2.5 × 10-6 M as limit detection, even under the presence of other metal ions.
Spatial Brain Control Interface using Optical and Electrophysiological Measures
2013-08-27
appropriate for implementing a reliable brain-computer interface ( BCI ). The LSVM method 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 27-08-2013 13...Machine (LSVM) was the most appropriate for implementing a reliable brain-computer interface ( BCI ). The LSVM method was applied to the imaging data...local field potentials proved to be fast and strongly tuned for the spatial parameters of the task. Thus, a reliable BCI that can predict upcoming
Lanini, Juliana; Galduróz, José Carlos Fernandes; Pompéia, Sabine
2016-01-01
Caffeine is widely used, often consumed with food, and improves simple and complex/executive attention under fasting conditions. We investigated whether these cognitive effects are observed when personalized habitual doses of caffeine are ingested by caffeine consumers, whether they are influenced by nutriments and if various executive domains are susceptible to improvement. This was a double-blind, placebo-controlled study including 60 young, healthy, rested males randomly assigned to one of four treatments: placebo fasting, caffeine fasting, placebo meal and caffeine meal. Caffeine doses were individualized for each participant based on their self-reported caffeine consumption at the time of testing (morning). The test battery included measures of simple and sustained attention, executive domains (inhibiting, updating, shifting, dual tasking, planning and accessing long-term memory), control measures of subjective alterations, glucose and insulin levels, skin conductance, heart rate and pupil dilation. Regardless of meal intake, acute habitual doses of caffeine decreased fatigue, and improved simple and sustained attention and executive updating. This executive effect was not secondary to the habitual weekly dose consumed, changes in simple and sustained attention, mood, meal ingestion and increases in cognitive effort. We conclude that the morning caffeine "fix" has positive attentional effects and selectively improved executive updating whether or not caffeine is consumed with food. Copyright © 2015 John Wiley & Sons, Ltd.
Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang
2013-09-01
We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.
M-Split: A Graphical User Interface to Analyze Multilayered Anisotropy from Shear Wave Splitting
NASA Astrophysics Data System (ADS)
Abgarmi, Bizhan; Ozacar, A. Arda
2017-04-01
Shear wave splitting analysis are commonly used to infer deep anisotropic structure. For simple cases, obtained delay times and fast-axis orientations are averaged from reliable results to define anisotropy beneath recording seismic stations. However, splitting parameters show systematic variations with back azimuth in the presence of complex anisotropy and cannot be represented by average time delay and fast axis orientation. Previous researchers had identified anisotropic complexities at different tectonic settings and applied various approaches to model them. Most commonly, such complexities are modeled by using multiple anisotropic layers with priori constraints from geologic data. In this study, a graphical user interface called M-Split is developed to easily process and model multilayered anisotropy with capabilities to properly address the inherited non-uniqueness. M-Split program runs user defined grid searches through the model parameter space for two-layer anisotropy using formulation of Silver and Savage (1994) and creates sensitivity contour plots to locate local maximas and analyze all possible models with parameter tradeoffs. In order to minimize model ambiguity and identify the robust model parameters, various misfit calculation procedures are also developed and embedded to M-Split which can be used depending on the quality of the observations and their back-azimuthal coverage. Case studies carried out to evaluate the reliability of the program using real noisy data and for this purpose stations from two different networks are utilized. First seismic network is the Kandilli Observatory and Earthquake research institute (KOERI) which includes long term running permanent stations and second network comprises seismic stations deployed temporary as part of the "Continental Dynamics-Central Anatolian Tectonics (CD-CAT)" project funded by NSF. It is also worth to note that M-Split is designed as open source program which can be modified by users for additional capabilities or for other applications.
NASA Astrophysics Data System (ADS)
Ling, Jun
Achieving reliable underwater acoustic communications (UAC) has long been recognized as a challenging problem owing to the scarce bandwidth available and the reverberant spread in both time and frequency domains. To pursue high data rates, we consider a multi-input multi-output (MIMO) UAC system, and our focus is placed on two main issues regarding a MIMO UAC system: (1) channel estimation, which involves the design of the training sequences and the development of a reliable channel estimation algorithm, and (2) symbol detection, which requires interference cancelation schemes due to simultaneous transmission from multiple transducers. To enhance channel estimation performance, we present a cyclic approach for designing training sequences with good auto- and cross-correlation properties, and a channel estimation algorithm called the iterative adaptive approach (IAA). Sparse channel estimates can be obtained by combining IAA with the Bayesian information criterion (BIC). Moreover, we present sparse learning via iterative minimization (SLIM) and demonstrate that SLIM gives similar performance to IAA but at a much lower computational cost. Furthermore, an extension of the SLIM algorithm is introduced to estimate the sparse and frequency modulated acoustic channels. The extended algorithm is referred to as generalization of SLIM (GoSLIM). Regarding symbol detection, a linear minimum mean-squared error based detection scheme, called RELAX-BLAST, which is a combination of vertical Bell Labs layered space-time (V-BLAST) algorithm and the cyclic principle of the RELAX algorithm, is presented and it is shown that RELAX-BLAST outperforms V-BLAST. We show that RELAX-BLAST can be implemented efficiently by making use of the conjugate gradient method and diagonalization properties of circulant matrices. This fast implementation approach requires only simple fast Fourier transform operations and facilitates parallel implementations. The effectiveness of the proposed MIMO schemes is verified by both computer simulations and experimental results obtained by analyzing the measurements acquired in multiple in-water experiments.
Estimating Measures of Pass-Fail Reliability from Parallel Half-Tests.
ERIC Educational Resources Information Center
Woodruff, David J.; Sawyer, Richard L.
Two methods for estimating measures of pass-fail reliability are derived, by which both theta and kappa may be estimated from a single test administration. The methods require only a single test administration and are computationally simple. Both are based on the Spearman-Brown formula for estimating stepped-up reliability. The non-distributional…
Eckner, James T.; Richardson, James K.; Kim, Hogene; Joshi, Monica S.; Oh, Youkeun K.; Ashton-Miller, James A.
2015-01-01
Summary Slowed reaction time (RT) represents both a risk factor for and a consequence of sport concussion. The purpose of this study was to determine the reliability and criterion validity of a novel clinical test of simple and complex RT, called RTclin, in contact sport athletes. Both tasks were adapted from the well-known ruler drop test of RT and involve manually grasping a falling vertical shaft upon its release, with the complex task employing a go/no-go paradigm based on a slight cue. In 46 healthy contact sport athletes (24 males; M = 16.3 yr., SD = 5.0; 22 women: M age= 15.0 yr., SD = 4.0) whose sports included soccer, ice hockey, American football, martial arts, wrestling, and lacrosse, the latency and accuracy of simple and complex RTclin had acceptable test-retest and inter-rater reliabilities and correlated with a computerized criterion standard, the Axon Computerized Cognitive Assessment Tool. Medium to large effect sizes were found. The novel RTclin tests have acceptable reliability and criterion validity for clinical use and hold promise as concussion assessment tools. PMID:26106803
Engineering Design Handbook: Reliable Military Electronics
1976-01-15
p. 30. CBS-Hytron: "I..ow-o::stPower Trall8istors," E1a::Drnic Design, 1 Nov. 1956, p. 24. Chang, C. M.: "An NPN High-Power Fast Germanium Col:e...34Monovibrator Has Fast Recovery Time," Electronics, Dec. 1957, p. 158. Carlson, A W. : "Junction Transistor Counters," EledronicDesign, 1 March 1957, p. 28...Method Makes Fast Pulses in Transistor Circuits," Electronic Design, 28 May 1958, p. 44. Stassior, R. A : "Pulse Applications cf a Diffused-Meltback
Jenerette, Coretta; Dixon, Jane
2010-10-01
Ethnic and cultural norms influence an individual's assertiveness. In health care, assertiveness may play an important role in health outcomes, especially for predominantly minority populations, such as adults with sickle cell disease. Therefore, it is important to develop measures to accurately assess assertiveness. It is also important to reduce response burden of lengthy instruments while retaining instrument reliability and validity. The purpose of this article is to describe development of a shorter version of the Simple Rathus Assertiveness Schedule (SRAS). Data from a cross-sectional descriptive study of adults with sickle cell disease were used to construct a short form of the SRAS, guided by stepwise regression analysis. The 19-item Simple Rathus Assertiveness Scale-Short Form (SRAS-SF) had acceptable reliability (α = .81) and construct validity and was highly correlated with the SRAS (r = .98, p = .01). The SRAS-SF reduces response burden, while maintaining reliability and validity.
Consistency of Lower-Body Dimensions Using Surface Landmarks and Simple Measurement Tools.
Caia, Johnpaul; Weiss, Lawrence W; Chiu, Loren Z F; Schilling, Brian K; Paquette, Max R
2016-09-01
Caia, J, Weiss, LW, Chiu, LZF, Schilling, BK, and Paquette, MR. Consistency of lower-body dimensions using surface landmarks and simple measurement tools. J Strength Cond Res 30(9): 2600-2608, 2016-Body dimensions may influence various types of physical performance. This study was designed to establish the reliability and precision of bilateral lower-body dimensions using surface anatomic landmarks and either sliding calipers or goniometry. Fifty university students (25 men and 25 women) were measured on 2 separate occasions separated by 48 or 72 hours. A small digital caliper was used to acquire longitudinal dimensions of the feet, whereas a larger broad-blade caliper was used to measure lower-limb, hip, and pelvic dimensions. Quadriceps angle (Q-angle) was determined through surface goniometry. Data for all foot and lower-limb dimensions were both reliable and precise (intraclass correlation coefficient (ICC) ≥0.72, SEM 0.1-0.5 cm). Measures of Q-angle were also reliable and precise (ICC ≥0.85, SEM 0.2-0.4°). Findings from this investigation demonstrate that lower-body dimensions may be reliably and precisely measured through simple practical tests, when surface anatomic landmarks and standardized procedures are used. Although intertester reliability remains to be established, meticulous adherence to specific measurement protocols is likely to yield viable output for lower-body dimensions when more sophisticated methods are unavailable or inappropriate.
Pereira, Leandro S A; Lisboa, Fernanda L C; Coelho Neto, José; Valladão, Frederico N; Sena, Marcelo M
2018-05-09
Several new psychoactive substances (NPS) have reached the illegal drug market in recent years, and ecstasy-like tablets are one of the forms affected by this change. Cathinones and tryptamines have increasingly been found in ecstasy-like seized samples as well as other amphetamine type stimulants. A presumptive method for identifying different drugs in seized ecstasy tablets (n=92) using ATR-FTIR (attenuated total reflectance - Fourier transform infrared spectroscopy) and PLS-DA (partial least squares discriminant analysis) was developed. A hierarchical strategy of sequential modeling was performed with PLS-DA. The main model discriminated four classes: 5-MeO-MIPT, methylenedioxyamphetamines (MDMA and MDA), methamphetamine, and cathinones. Two submodels were built to identify drugs present in MDs and cathinones classes. Models were validated through the estimate of figures of merit. The average reliability rate (RLR) of the main model was 96.8% and accordance (ACC) was 100%. For the submodels, RLR and ACC were 100%. The reliability of the models was corroborated through their spectral interpretation. Thus, spectral assignments were performed by associating informative vectors of each specific modeled class to the respective drugs. The developed method is simple, fast, and can be applied to the forensic laboratory routine, leading to objective results reports useful for forensic scientists and law enforcement. Copyright © 2018 Elsevier B.V. All rights reserved.
Walke, Peter; Fujita, Yasuhiko; Peeters, Wannes; Toyouchi, Shuichi; Frederickx, Wout; De Feyter, Steven; Uji-I, Hiroshi
2018-04-26
Tip-enhanced Raman scattering (TERS) microscopy is a unique analytical tool to provide complementary chemical and topographic information of surfaces with nanometric resolution. However, difficulties in reliably producing the necessary metallized scanning probe tips has limited its widespread utilisation, particularly in the case of cantilever-based atomic force microscopy. Attempts to alleviate tip related issues using colloidal or bottom-up engineered tips have so far not reported consistent probes for both Raman and topographic imaging. Here we demonstrate the reproducible fabrication of cantilever-based high-performance TERS probes for both topographic and Raman measurements, based on an approach that utilises noble metal nanowires as the active TERS probe. The tips show 10 times higher TERS contrasts than the most typically used electrochemically-etched tips, and show a reproducibility for TERS greater than 90%, far greater than found with standard methods. We show that TERS can be performed in tapping as well as contact AFM mode, with optical resolutions around or below 15 nm, and with a maximum resolution achieved in tapping-mode of 6 nm. Our work illustrates that superior TERS probes can be produced in a fast and cost-effective manner using simple wet-chemistry methods, leading to reliable and reproducible high-resolution and high-sensitivity TERS, and thus renders the technique applicable for a broad community.
A pipette-based calibration system for fast-scan cyclic voltammetry with fast response times.
Ramsson, Eric S
2016-01-01
Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique that utilizes the oxidation and/or reduction of an analyte of interest to infer rapid changes in concentrations. In order to calibrate the resulting oxidative or reductive current, known concentrations of an analyte must be introduced under controlled settings. Here, I describe a simple and cost-effective method, using a Petri dish and pipettes, for the calibration of carbon fiber microelectrodes (CFMs) using FSCV.
Subject-level reliability analysis of fast fMRI with application to epilepsy.
Hao, Yongfu; Khoo, Hui Ming; von Ellenrieder, Nicolas; Gotman, Jean
2017-07-01
Recent studies have applied the new magnetic resonance encephalography (MREG) sequence to the study of interictal epileptic discharges (IEDs) in the electroencephalogram (EEG) of epileptic patients. However, there are no criteria to quantitatively evaluate different processing methods, to properly use the new sequence. We evaluated different processing steps of this new sequence under the common generalized linear model (GLM) framework by assessing the reliability of results. A bootstrap sampling technique was first used to generate multiple replicated data sets; a GLM with different processing steps was then applied to obtain activation maps, and the reliability of these maps was assessed. We applied our analysis in an event-related GLM related to IEDs. A higher reliability was achieved by using a GLM with head motion confound regressor with 24 components rather than the usual 6, with an autoregressive model of order 5 and with a canonical hemodynamic response function (HRF) rather than variable latency or patient-specific HRFs. Comparison of activation with IED field also favored the canonical HRF, consistent with the reliability analysis. The reliability analysis helps to optimize the processing methods for this fast fMRI sequence, in a context in which we do not know the ground truth of activation areas. Magn Reson Med 78:370-382, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Gog, Simon; Bader, Martin
2008-10-01
The problem of sorting signed permutations by reversals is a well-studied problem in computational biology. The first polynomial time algorithm was presented by Hannenhalli and Pevzner in 1995. The algorithm was improved several times, and nowadays the most efficient algorithm has a subquadratic running time. Simple permutations played an important role in the development of these algorithms. Although the latest result of Tannier et al. does not require simple permutations, the preliminary version of their algorithm as well as the first polynomial time algorithm of Hannenhalli and Pevzner use the structure of simple permutations. More precisely, the latter algorithms require a precomputation that transforms a permutation into an equivalent simple permutation. To the best of our knowledge, all published algorithms for this transformation have at least a quadratic running time. For further investigations on genome rearrangement problems, the existence of a fast algorithm for the transformation could be crucial. Another important task is the back transformation, i.e. if we have a sorting on the simple permutation, transform it into a sorting on the original permutation. Again, the naive approach results in an algorithm with quadratic running time. In this paper, we present a linear time algorithm for transforming a permutation into an equivalent simple permutation, and an O(n log n) algorithm for the back transformation of the sorting sequence.
Assuring reliability program effectiveness.
NASA Technical Reports Server (NTRS)
Ball, L. W.
1973-01-01
An attempt is made to provide simple identification and description of techniques that have proved to be most useful either in developing a new product or in improving reliability of an established product. The first reliability task is obtaining and organizing parts failure rate data. Other tasks are parts screening, tabulation of general failure rates, preventive maintenance, prediction of new product reliability, and statistical demonstration of achieved reliability. Five principal tasks for improving reliability involve the physics of failure research, derating of internal stresses, control of external stresses, functional redundancy, and failure effects control. A final task is the training and motivation of reliability specialist engineers.
Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.
Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J
2013-01-01
In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.
Kaur, Jaspreet; Srinivasan, K. K.; Joseph, Alex; Gupta, Abhishek; Singh, Yogendra; Srinivas, Kona S.; Jain, Garima
2010-01-01
Objective: Venlafaxine,hydrochloride is a structurally novel phenethyl bicyclic antidepressant, and is usually categorized as a serotonin–norepinephrine reuptake inhibitor (SNRI) but it has been referred to as a serotonin–norepinephrine–dopamine reuptake inhibitor. It inhibits the reuptake of dopamine. Venlafaxine HCL is widely prescribed in the form of sustained release formulations. In the current article we are reporting the development and validation of a fast and simple stability indicating, isocratic high performance liquid chromatographic (HPLC) method for the determination of venlafaxine hydrochloride in sustained release formulations. Materials and Methods: The quantitative determination of venlafaxine hydrochloride was performed on a Kromasil C18 analytical column (250 × 4.6 mm i.d., 5 μm particle size) with 0.01 M phosphate buffer (pH 4.5): methanol (40: 60) as a mobile phase, at a flow rate of 1.0 ml/min. For HPLC methods, UV detection was made at 225 nm. Results: During method validation, parameters such as precision, linearity, accuracy, stability, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions: The method has been successfully applied for the quantification and dissolution profiling of Venlafaxine HCL in sustained release formulation. The method presents a simple and reliable solution for the routine quantitative analysis of Venlafaxine HCL. PMID:21814426
NASA Astrophysics Data System (ADS)
Michalik-Onichimowska, Aleksandra; Kern, Simon; Riedel, Jens; Panne, Ulrich; King, Rudibert; Maiwald, Michael
2017-04-01
Driven mostly by the search for chemical syntheses under biocompatible conditions, so called "click" chemistry rapidly became a growing field of research. The resulting simple one-pot reactions are so far only scarcely accompanied by an adequate optimization via comparably straightforward and robust analysis techniques possessing short set-up times. Here, we report on a fast and reliable calibration-free online NMR monitoring approach for technical mixtures. It combines a versatile fluidic system, continuous-flow measurement of 1H spectra with a time interval of 20 s per spectrum, and a robust, fully automated algorithm to interpret the obtained data. As a proof-of-concept, the thiol-ene coupling between N-boc cysteine methyl ester and allyl alcohol was conducted in a variety of non-deuterated solvents while its time-resolved behaviour was characterized with step tracer experiments. Overlapping signals in online spectra during thiol-ene coupling could be deconvoluted with a spectral model using indirect hard modeling and were subsequently converted to either molar ratios (using a calibration-free approach) or absolute concentrations (using 1-point calibration). For various solvents the kinetic constant k for pseudo-first order reaction was estimated to be 3.9 h-1 at 25 °C. The obtained results were compared with direct integration of non-overlapping signals and showed good agreement with the implemented mass balance.
Pimentel, Lígia; Fontes, Ana Luiza; Salsinha, Sofia; Machado, Manuela; Correia, Inês; Gomes, Ana Maria; Pintado, Manuela; Rodríguez-Alcalá, Luís Miguel
2018-03-08
Lipids are gaining relevance over the last 20 years, as our knowledge about their role has changed from merely energy/structural molecules to compounds also involved in several biological processes. This led to the creation in 2003 of a new emerging research field: lipidomics. In particular the phospholipids have pharmacological/food applications, participate in cell signalling/homeostatic pathways while their analysis faces some challenges. Their fractionation/purification is, in fact, especially difficult, as they are amphiphilic compounds. Moreover, it usually involves SPE or TLC procedures requiring specific materials hampering their suitableness for routine analysis. Finally, they can interfere with the ionization of other molecules during mass spectrometry analysis. Thus, simple high-throughput reliable methods to selectively isolate these compounds based on the difference between chemical characteristics of lipids would represent valuable tools for their study besides that of other compounds. The current review work aims to describe the state-of-the-art related to the extraction of phospholipids using liquid-liquid methods for their targeted isolation. The technological and biological importance of these compounds and ion suppression phenomena are also reviewed. Methods by precipitation with acetone or isolation using methanol seem to be suitable for selective isolation of phospholipids in both biological and food samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Estimation of interhemispheric dynamics from simple unimanual reaction time to extrafoveal stimuli.
Braun, C M
1992-12-01
This essay reviews research on interhemispheric transfer time derived from simple unimanual reaction time to hemitachistoscopically presented visual stimuli. Part 1 reviews major theoretical themes including (a) the significance of the eccentricity effect on interhemispheric transfer time in the context of proposed underlying neurohistological constraints; (b) the significance of gender differences in interhemispheric transfer time and findings in dyslexics and left-handers in the context of a fetal brain testosterone model; and (c) the significance of complexity effects on interhemispheric transfer time in a context of "dynamic" vs. "hard-wired" concepts of the underlying interhemispheric communication systems. Part 2 consists of a meta-analysis of 49 published behavioral experiments, in view of drawing a portrait of the best set of experimental conditions apt to produce salient, reliable, and statistically significant measures of interhemispheric transfer time, namely (a) index rather than thumb response, (b) low rather than high target luminance, (c) short rather than prolonged target display, and (d) very eccentric rather than near-foveal stimulus location. Part 3 proposes a theoretical model of interhemispheric transfer time, postulating the measurable existence of fast and slow interhemispheric channels. The proposed mechanism's evolutionary adaptive value, the neurophysiological evidence in its support, and favorable functional evidence from studies of callosotomized patients are then presented followed by proposals for critical experimental tests of the model.
Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin
2017-01-01
A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.
ERIC Educational Resources Information Center
Cooke, Jason; Hebert, Dominique; Kelly, Joel A.
2015-01-01
This work describes a convenient and reliable laboratory experiment in nanochemistry that is flexible and adaptable to a wide range of educational settings. The rapid preparation of yellow colloidal silver nanoparticles is achieved by glucose reduction of silver nitrate in the presence of starch and sodium citrate in gently boiling water, using…
The Effect of Raters and Rating Conditions on the Reliability of the Missionary Teaching Assessment
ERIC Educational Resources Information Center
Ure, Abigail C.
2011-01-01
This study investigated how 2 different rating conditions, the controlled rating condition (CRC) and the uncontrolled rating condition (URC), effected rater behavior and the reliability of a performance assessment (PA) known as the Missionary Teaching Assessment (MTA). The CRC gives raters the capability to manipulate (pause, rewind, fast-forward)…
Simple and fast screening of G-quadruplex ligands with electrochemical detection system.
Fan, Qiongxuan; Li, Chao; Tao, Yaqin; Mao, Xiaoxia; Li, Genxi
2016-11-01
Small molecules that may facilitate and stabilize the formation of G-quadruplexes can be used for cancer treatments, because the G-quadruplex structure can inhibit the activity of telomerase, an enzyme over-expressed in many cancer cells. Therefore, there is considerable interest in developing a simple and high-performance method for screening small molecules binding to G-quadruplex. Here, we have designed a simple electrochemical approach to screen such ligands based on the fact that the formation and stabilization of G-quadruplex by ligand may inhibit electron transfer of redox species to electrode surface. As a proof-of-concept study, two types of classical G-quadruplex ligands, TMPyP4 and BRACO-19, are studied in this work, which demonstrates that this method is fast and robust and it may be applied to screen G-quadruplex ligands for anticancer drugs testing and design in the future. Copyright © 2016 Elsevier B.V. All rights reserved.
Kon', I Ia; Volkova, L Iu; Sannikova, N E; Dzhumagaziev, A A; Aleshina, I V; Toboleva, M A; Korosteleva, M M
2010-01-01
Overweight appear one of the serious problem in European region WHO today. Obesity is polyetiological disease and result of different factors. The aim of the current studies was investigation of connection between consumption confectionary, fast food stuffs and soft drinks and body-mass index (BMI). At the beginning, was inspection of 434 schoolchildren 7-18 age old. As a result, was determined, that confectionary, fast food stuffs and soft drinks mach more popular, than ever stuffs. At the same time, was determined, that mean significance BMI was reliable above for children, who used confectionary, fast food stuffs and soft drinks frequently.
Desert ants achieve reliable recruitment across noisy interactions
Razin, Nitzan; Eckmann, Jean-Pierre; Feinerman, Ofer
2013-01-01
We study how desert ants, Cataglyphis niger, a species that lacks pheromone-based recruitment mechanisms, inform each other about the presence of food. Our results are based on automated tracking that allows us to collect a large database of ant trajectories and interactions. We find that interactions affect an ant's speed within the nest. Fast ants tend to slow down, whereas slow ones increase their speed when encountering a faster ant. Faster ants tend to exit the nest more frequently than slower ones. So, if an ant gains enough speed through encounters with others, then she tends to leave the nest and look for food. On the other hand, we find that the probability for her to leave the nest depends only on her speed, but not on whether she had recently interacted with a recruiter that has found the food. This suggests a recruitment system in which ants communicate their state by very simple interactions. Based on this assumption, we estimate the information-theoretical channel capacity of the ants’ pairwise interactions. We find that the response to the speed of an interacting nest-mate is very noisy. The question is then how random interactions with ants within the nest can be distinguished from those interactions with a recruiter who has found food. Our measurements and model suggest that this distinction does not depend on reliable communication but on behavioural differences between ants that have found the food and those that have not. Recruiters retain high speeds throughout the experiment, regardless of the ants they interact with; non-recruiters communicate with a limited number of nest-mates and adjust their speed following these interactions. These simple rules lead to the formation of a bistable switch on the level of the group that allows the distinction between recruitment and random noise in the nest. A consequence of the mechanism we propose is a negative effect of ant density on exit rates and recruitment success. This is, indeed, confirmed by our measurements. PMID:23486172
Negredo, F; Blaicher, M; Nesic, A; Kraft, P; Ott, J; Dörfler, W; Koos, C; Rockstuhl, C
2018-06-01
Photonic wire bonds, i.e., freeform waveguides written by 3D direct laser writing, emerge as a technology to connect different optical chips in fully integrated photonic devices. With the long-term vision of scaling up this technology to a large-scale fabrication process, the in situ optimization of the trajectory of photonic wire bonds is at stake. A prerequisite for the real-time optimization is the availability of a fast loss estimator for single-mode waveguides of arbitrary trajectory. Losses occur because of the bending of the waveguides and at transitions among sections of the waveguide with different curvatures. Here, we present an approach that resides on the fundamental mode approximation, i.e., the assumption that the photonic wire bonds predominantly carry their energy in a single mode. It allows us to predict in a quick and reliable way the pertinent losses from pre-computed modal properties of the waveguide, enabling fast design of optimum paths.
A New Approximate Chimera Donor Cell Search Algorithm
NASA Technical Reports Server (NTRS)
Holst, Terry L.; Nixon, David (Technical Monitor)
1998-01-01
The objectives of this study were to develop chimera-based full potential methodology which is compatible with overflow (Euler/Navier-Stokes) chimera flow solver and to develop a fast donor cell search algorithm that is compatible with the chimera full potential approach. Results of this work included presenting a new donor cell search algorithm suitable for use with a chimera-based full potential solver. This algorithm was found to be extremely fast and simple producing donor cells as fast as 60,000 per second.
NASA Technical Reports Server (NTRS)
Unal, Resit; Morris, W. Douglas; White, Nancy H.; Lepsch, Roger A.; Brown, Richard W.
2000-01-01
This paper describes the development of parametric models for estimating operational reliability and maintainability (R&M) characteristics for reusable vehicle concepts, based on vehicle size and technology support level. A R&M analysis tool (RMAT) and response surface methods are utilized to build parametric approximation models for rapidly estimating operational R&M characteristics such as mission completion reliability. These models that approximate RMAT, can then be utilized for fast analysis of operational requirements, for lifecycle cost estimating and for multidisciplinary sign optimization.
Not So Fast! (and Not So Frugal!): Rethinking the Recognition Heuristic
ERIC Educational Resources Information Center
Oppenheimer, Daniel M.
2003-01-01
The "fast and frugal" approach to reasoning (Gigerenzer, G., & Todd, P. M. (1999). "Simple heuristics that make us smart." New York: Oxford University Press) claims that individuals use non-compensatory strategies in judgment--the idea that only one cue is taken into account in reasoning. The simplest and most important of these heuristics…
Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School
ERIC Educational Resources Information Center
Bogacz, Bogdan F.; Pedziwiatr, Antoni T.
2014-01-01
A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…
Fast or Frugal, but Not Both: Decision Heuristics under Time Pressure
ERIC Educational Resources Information Center
Bobadilla-Suarez, Sebastian; Love, Bradley C.
2018-01-01
Heuristics are simple, yet effective, strategies that people use to make decisions. Because heuristics do not require all available information, they are thought to be easy to implement and to not tax limited cognitive resources, which has led heuristics to be characterized as fast-and-frugal. We question this monolithic conception of heuristics…
Operator priming and generalization of practice in adults' simple arithmetic.
Chen, Yalin; Campbell, Jamie I D
2016-04-01
There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication, suggesting that a general addition procedure was primed by the + sign. In Experiment 1 (n = 36), we applied this operator-priming paradigm to rule-based problems (0 + N = N, 1 × N = N, 0 × N = 0) and 1 + N problems with N ranging from 0 to 9. For the rule-based problems, we found both operator-preview facilitation and generalization of practice (e.g., practicing 0 + 3 sped up unpracticed 0 + 8), the latter being a signature of procedure use; however, we also found operator-preview facilitation for 1 + N in the absence of generalization, which implies the 1 + N problems were solved by fact retrieval but nonetheless were facilitated by an operator preview. Thus, the operator preview effect does not discriminate procedure use from fact retrieval. Experiment 2 (n = 36) investigated whether a population with advanced mathematical training-engineering and computer science students-would show generalization of practice for nonrule-based simple addition problems (e.g., 1 + 4, 4 + 7). The 0 + N problems again presented generalization, whereas no nonzero problem type did; but all nonzero problems sped up when the identical problems were retested, as predicted by item-specific fact retrieval. The results pose a strong challenge to the generality of the proposal that skilled adults' simple addition is based on fast procedural algorithms, and instead support a fact-retrieval model of fast addition performance. (c) 2016 APA, all rights reserved).
de Oliveira, Marcelo Firmino; Vieira, Andressa Tironi; Batista, Antônio Carlos Ferreira; Rodrigues, Hugo de Souza; Stradiotto, Nelson Ramos
2011-01-01
A simple, fast, and complete route for the production of methylic and ethylic biodiesel from tucum oil is described. Aliquots of the oil obtained directly from pressed tucum (pulp and almonds) were treated with potassium methoxide or ethoxide at 40°C for 40 min. The biodiesel form was removed from the reactor and washed with 0.1 M HCl aqueous solution. A simple distillation at 100°C was carried out in order to remove water and alcohol species from the biodiesel. The oxidative stability index was obtained for the tucum oil as well as the methylic and ethylic biodiesel at 6.13, 2.90, and 2.80 h, for storage times higher than 8 days. Quality control of the original oil and of the methylic and ethylic biodiesels, such as the amount of glycerin produced during the transesterification process, was accomplished by the TLC, GC-MS, and FT-IR techniques. The results obtained in this study indicate a potential biofuel production by simple treatment of tucum, an important Amazonian fruit. PMID:21629751
Fast and accurate image recognition algorithms for fresh produce food safety sensing
NASA Astrophysics Data System (ADS)
Yang, Chun-Chieh; Kim, Moon S.; Chao, Kuanglin; Kang, Sukwon; Lefcourt, Alan M.
2011-06-01
This research developed and evaluated the multispectral algorithms derived from hyperspectral line-scan fluorescence imaging under violet LED excitation for detection of fecal contamination on Golden Delicious apples. The algorithms utilized the fluorescence intensities at four wavebands, 680 nm, 684 nm, 720 nm, and 780 nm, for computation of simple functions for effective detection of contamination spots created on the apple surfaces using four concentrations of aqueous fecal dilutions. The algorithms detected more than 99% of the fecal spots. The effective detection of feces showed that a simple multispectral fluorescence imaging algorithm based on violet LED excitation may be appropriate to detect fecal contamination on fast-speed apple processing lines.
Duration as a measure of the spiral aftereffect.
DOT National Transportation Integrated Search
1963-01-01
Describes an experiment that studied the reliability of duration as a measure of the spiral aftereffect. The results for 10 Ss indicate that duration is a highly reliable measure and that duration is a simple monotonic function of exposure-time.
Enhanced parent selection algorithms in mintroute protocol
NASA Astrophysics Data System (ADS)
Kim, Ki-Il
2012-11-01
A low-rate, short-range wireless radio communication on a small device often hampers high reliability in wireless sensor networks. However, more applications are increasingly demanding high reliability. To meet this requirement, various approaches have been proposed in each viewpoint of layers. Among those, MintRoute is a well-known network layer approach to develop a new metric based on link quality for path selection towards the sink. By choosing the link with the highest measured value, it has a higher possibility to transmit a packet over the link without error. However, there are still several issues to be mentioned during operations. In this paper, we propose how to improve the MintRoute protocol through revised algorithms. They include a parent selection considering distance and level from the sink node, and a fast recovery method against failures. Simulations and analysis are performed by in order to validate the suitability of reduced end-to-end delay and fast recovery for failures, thus to enhance the reliability of communication.
2011-01-01
Background Bleach-sedimentation may improve microscopy for diagnosing tuberculosis by sterilising sputum and concentrating Mycobacterium tuberculosis. We studied gravity bleach-sedimentation effects on safety, sensitivity, speed and reliability of smear-microscopy. Methods This blinded, controlled study used sputum specimens (n = 72) from tuberculosis patients. Bleach concentrations and exposure times required to sterilise sputum (n = 31) were determined. In the light of these results, the performance of 5 gravity bleach-sedimentation techniques that sterilise sputum specimens (n = 16) were compared. The best-performing of these bleach-sedimentation techniques involved adding 1 volume of 5% bleach to 1 volume of sputum, shaking for 10-minutes, diluting in 8 volumes distilled water and sedimenting overnight before microscopy. This technique was further evaluated by comparing numbers of visible acid-fast bacilli, slide-reading speed and reliability for triplicate smears before versus after bleach-sedimentation of sputum specimens (n = 25). Triplicate smears were made to increase precision and were stained using the Ziehl-Neelsen method. Results M. tuberculosis in sputum was successfully sterilised by adding equal volumes of 15% bleach for 1-minute, 6% for 5-minutes or 3% for 20-minutes. Bleach-sedimentation significantly decreased the number of acid-fast bacilli visualised compared with conventional smears (geometric mean of acid-fast bacilli per 100 microscopy fields 166, 95%CI 68-406, versus 346, 95%CI 139-862, respectively; p = 0.02). Bleach-sedimentation diluted paucibacillary specimens less than specimens with higher concentrations of visible acid-fast bacilli (p = 0.02). Smears made from bleach-sedimented sputum were read more rapidly than conventional smears (9.6 versus 11.2 minutes, respectively, p = 0.03). Counting conventional acid-fast bacilli had high reliability (inter-observer agreement, r = 0.991) that was significantly reduced (p = 0.03) by bleach-sedimentation (to r = 0.707) because occasional strongly positive bleach-sedimented smears were misread as negative. Conclusions Gravity bleach-sedimentation improved laboratory safety by sterilising sputum but decreased the concentration of acid-fast bacilli visible on microscopy, especially for sputum specimens containing high concentrations of M. tuberculosis. Bleach-sedimentation allowed examination of more of each specimen in the time available but decreased the inter-observer reliability with which slides were read. Thus bleach-sedimentation effects vary depending upon specimen characteristics and whether microscopy was done for a specified time, or until a specified number of microscopy fields had been read. These findings provide an explanation for the contradictory results of previous studies. PMID:21985457
Evaluating North American Electric Grid Reliability Using the Barabasi-Albert Network Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chassin, David P.; Posse, Christian
2005-09-15
The reliability of electric transmission systems is examined using a scale-free model of network topology and failure propagation. The topologies of the North American eastern and western electric grids are analyzed to estimate their reliability based on the Barabási-Albert network model. A commonly used power system reliability index is computed using a simple failure propagation model. The results are compared to the values of power system reliability indices previously obtained using other methods and they suggest that scale-free network models are usable to estimate aggregate electric grid reliability.
Evaluating North American Electric Grid Reliability Using the Barabasi-Albert Network Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chassin, David P.; Posse, Christian
2005-09-15
The reliability of electric transmission systems is examined using a scale-free model of network topology and failure propagation. The topologies of the North American eastern and western electric grids are analyzed to estimate their reliability based on the Barabasi-Albert network model. A commonly used power system reliability index is computed using a simple failure propagation model. The results are compared to the values of power system reliability indices previously obtained using standard power engineering methods, and they suggest that scale-free network models are usable to estimate aggregate electric grid reliability.
NASA Technical Reports Server (NTRS)
Trela, W.
1980-01-01
The paper reviews the progress of the major technical tasks of the DOE/NASA/Ford program Evaluation of Ceramics for Stator Applications in Automotive Gas Turbine Engines: reliability prediction, stator fabrication, material characterization, and stator evaluation. A fast fracture reliability model was prepared for a one-piece ceramic stator. Periodic inspection results are presented.
Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.
Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren
2014-01-01
This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.
Javorska, Lenka; Krcmova, Lenka Kujovska; Solich, Petr; Kaska, Milan
2017-08-05
Management of the therapy of life-threatening bacterial infection is extremely based on an optimal antibiotic treatment. Achieving the correct vancomycin dosage in blood and target tissues can be complicated in special situations, e.g., where large fluid sequestration and/or acute renal failure occur. A UHPLC-MS/MS method operating in electrospray (ESI) positive ion mode was applied for the determination of vancomycin in serum, urine and peritoneal/pleural effusion. Sample pretreatment was composed of dilution and simple protein precipitation where only a small volume (50μL) of serum, urine or peritoneal/pleural effusion was required. The separation of vancomycin was performed on a Meteoric Core C18 BIO column (100×4.6mm, 2.7μm) by gradient elution with 0.1% formic acid in water and acetonitrile. The total time of analysis was 4.5min. The method was found to be linear in the range of 2-60μM (or 0.5-10μM) for serum, 0.27-10μM (or 2-60μM) for peritoneal/pleural effusion and 25-300μM for urine, which was adequate for the determination of vancomycin in patient samples. The intra- and inter-day precision was below 8% RSD, and accuracy was from 89 to 104%. The UHPLC/MS-MS method offers a fast and reliable approach to determine vancomycin concentrations in three different human body fluid samples (serum, urine and peritoneal/pleural effusion) with a simple sample pretreatment that was the same for all selected specimens. This method should be applicable to large sample series in clinical (pharmacokinetic/pharmacodynamic) studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Status of liquid metal fast breeder reactor fuel development in Japan
NASA Astrophysics Data System (ADS)
Katsuragawa, M.; Kashihara, H.; Akebi, M.
1993-09-01
The mixed-oxide fuel technology for a liquid metal fast breeder reactor (LMFBR) in Japan is progressing toward commercial deployment of LMFBR. Based on accumulated experience in Joyo and Monju fuel development, efforts for large scale LMFBR fuel development are devoted to improved irradiation performance, reliability and economy. This paper summarizes accomplishments, current activities and future plans for LMFBR fuel development in Japan.
Fast Computation and Assessment Methods in Power System Analysis
NASA Astrophysics Data System (ADS)
Nagata, Masaki
Power system analysis is essential for efficient and reliable power system operation and control. Recently, online security assessment system has become of importance, as more efficient use of power networks is eagerly required. In this article, fast power system analysis techniques such as contingency screening, parallel processing and intelligent systems application are briefly surveyed from the view point of their application to online dynamic security assessment.
Simple algorithm for improved security in the FDDI protocol
NASA Astrophysics Data System (ADS)
Lundy, G. M.; Jones, Benjamin
1993-02-01
We propose a modification to the Fiber Distributed Data Interface (FDDI) protocol based on a simple algorithm which will improve confidential communication capability. This proposed modification provides a simple and reliable system which exploits some of the inherent security properties in a fiber optic ring network. This method differs from conventional methods in that end to end encryption can be facilitated at the media access control sublayer of the data link layer in the OSI network model. Our method is based on a variation of the bit stream cipher method. The transmitting station takes the intended confidential message and uses a simple modulo two addition operation against an initialization vector. The encrypted message is virtually unbreakable without the initialization vector. None of the stations on the ring will have access to both the encrypted message and the initialization vector except the transmitting and receiving stations. The generation of the initialization vector is unique for each confidential transmission and thus provides a unique approach to the key distribution problem. The FDDI protocol is of particular interest to the military in terms of LAN/MAN implementations. Both the Army and the Navy are considering the standard as the basis for future network systems. A simple and reliable security mechanism with the potential to support realtime communications is a necessary consideration in the implementation of these systems. The proposed method offers several advantages over traditional methods in terms of speed, reliability, and standardization.
Redundant disk arrays: Reliable, parallel secondary storage. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Gibson, Garth Alan
1990-01-01
During the past decade, advances in processor and memory technology have given rise to increases in computational performance that far outstrip increases in the performance of secondary storage technology. Coupled with emerging small-disk technology, disk arrays provide the cost, volume, and capacity of current disk subsystems, by leveraging parallelism, many times their performance. Unfortunately, arrays of small disks may have much higher failure rates than the single large disks they replace. Redundant arrays of inexpensive disks (RAID) use simple redundancy schemes to provide high data reliability. The data encoding, performance, and reliability of redundant disk arrays are investigated. Organizing redundant data into a disk array is treated as a coding problem. Among alternatives examined, codes as simple as parity are shown to effectively correct single, self-identifying disk failures.
Rubino, Stefano; Akhtar, Sultan; Leifer, Klaus
2016-02-01
We present a simple, fast method for thickness characterization of suspended graphene/graphite flakes that is based on transmission electron microscopy (TEM). We derive an analytical expression for the intensity of the transmitted electron beam I 0(t), as a function of the specimen thickness t (t<λ; where λ is the absorption constant for graphite). We show that in thin graphite crystals the transmitted intensity is a linear function of t. Furthermore, high-resolution (HR) TEM simulations are performed to obtain λ for a 001 zone axis orientation, in a two-beam case and in a low symmetry orientation. Subsequently, HR (used to determine t) and bright-field (to measure I 0(0) and I 0(t)) images were acquired to experimentally determine λ. The experimental value measured in low symmetry orientation matches the calculated value (i.e., λ=225±9 nm). The simulations also show that the linear approximation is valid up to a sample thickness of 3-4 nm regardless of the orientation and up to several ten nanometers for a low symmetry orientation. When compared with standard techniques for thickness determination of graphene/graphite, the method we propose has the advantage of being simple and fast, requiring only the acquisition of bright-field images.
The fast kinematic magnetic dynamo and the dissipationless limit
NASA Technical Reports Server (NTRS)
Finn, John M.; Ott, Edward
1990-01-01
The evolution of the magnetic field in models that incorporate chaotic field line stretching, field cancellation, and finite magnetic Reynolds number is examined analytically and numerically. Although the models used here are highly idealized, it is claimed that they display and illustrate typical behavior relevant to fast magnetic dynamic behavior. It is shown, in particular, that consideration of magnetic flux through a finite fixed surface provides a simple and effective way of deducing fast dynamo behavior from the zero resistivity equation. Certain aspects of the fast dynamo problem can thus be reduced to a study of nonlinear dynamic properties of the underlying flow.
Structural Reliability and Monte Carlo Simulation.
ERIC Educational Resources Information Center
Laumakis, P. J.; Harlow, G.
2002-01-01
Analyzes a simple boom structure and assesses its reliability using elementary engineering mechanics. Demonstrates the power and utility of Monte-Carlo simulation by showing that such a simulation can be implemented more readily with results that compare favorably to the theoretical calculations. (Author/MM)
Montare, Alberto
2013-06-01
The three classical Donders' reaction time (RT) tasks (simple, choice, and discriminative RTs) were employed to compare reaction time scores from college students obtained by use of Montare's simplest chronoscope (meterstick) methodology to scores obtained by use of a digital-readout multi-choice reaction timer (machine). Five hypotheses were tested. Simple RT, choice RT, and discriminative RT were faster when obtained by meterstick than by machine. The meterstick method showed higher reliability than the machine method and was less variable. The meterstick method of the simplest chronoscope may help to alleviate the longstanding problems of low reliability and high variability of reaction time performances; while at the same time producing faster performance on Donders' simple, choice and discriminative RT tasks than the machine method.
Kim, Jeong Ah; Kim, Moojong; Kang, Sung Min; Lim, Kun Taek; Kim, Tae Song; Kang, Ji Yoon
2015-05-15
Despite scientific progress in the study of Alzheimer's disease (AD), it is still challenging to develop a robust and sensitive methodology for the early diagnosis of AD due to the lack of a decisive biomarker in blood. Recent reports on the oligomer amyloid β (Aβ) as a biomarker demonstrated its possibility for identifying early onset of AD in patients, but its low concentration in blood requires highly reliable detection techniques. To overcome the low reliability and labor-intensive procedures of conventional enzyme-linked immunosorbent assay (ELISA), we present a magnetic bead-droplet immunoassay platform for simple and highly sensitive detection of oligomer Aβ for the diagnosis of AD. This microchip consists of chambers that contain water-based reagents or oil for consecutive assay procedures, and there are arrays of micro-pillars fabricated between the two adjacent chambers to form robust water-oil interfaces. With the aid of these micro-pillars, magnetic beads can stably pass through each chamber by linearly actuating a magnet along the microchip. The robust water-oil interface and simple procedures of the assay make it possible to obtain reliable results from this microchip. The intensity of the fluorescence at the read-out chamber increased quantitatively and linearly, depending on the amount of serially-diluted standard Aβ solution. The results of the assay indicated that the limit of detection was about 10 pg/mL even though it was done with manual manipulation of the magnet. This platform simplified the complicated ELISA procedure and achieved high sensitivity that was no lower than that of the conventional magnetic bead immunoassay. The magnetic bead-droplet platform reduced the assay time to 45 min, and it also reduced the amount of antibody usage in a single diagnosis significantly (10-30 ng of antibody per single assay). Consequently, this microfluidic chip has strong potential as a feasible system for use in the diagnosis of AD with a fast and easy immunoassay process, since the suggested platform can be automated with ease for point-of-care testing as well as high-throughput diagnostic equipment. Copyright © 2014 Elsevier B.V. All rights reserved.
De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip
2017-01-01
Background: Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. Aim: This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. Materials and Methods: All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. Results: A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. Conclusion: The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL. PMID:29263539
ERIC Educational Resources Information Center
Digilov, Rafael M.
2008-01-01
We describe a simple and very inexpensive undergraduate laboratory experiment for fast determination of Young's modulus at moderate temperatures with the aid of a force sensor. A strip-shaped specimen rigidly bolted to the force sensor forms a clamped-free cantilever beam. Placed in a furnace, it is subjected to free-bending vibrations followed by…
NASA Astrophysics Data System (ADS)
Lee, Chang-Kun; Moon, Seokil; Lee, Byounghyo; Jeong, Youngmo; Lee, Byoungho
2016-10-01
A head-mounted compressive three-dimensional (3D) display system is proposed by combining polarization beam splitter (PBS), fast switching polarization rotator and micro display with high pixel density. According to the polarization state of the image controlled by polarization rotator, optical path of image in the PBS can be divided into transmitted and reflected components. Since optical paths of each image are spatially separated, it is possible to independently focus both images at different depth positions. Transmitted p-polarized and reflected s-polarized images can be focused by convex lens and mirror, respectively. When the focal lengths of the convex lens and mirror are properly determined, two image planes can be located in intended positions. The geometrical relationship is easily modulated by replacement of the components. The fast switching of polarization realizes the real-time operation of multi-focal image planes with a single display panel. Since it is possible to conserve the device characteristic of single panel, the high image quality, reliability and uniformity can be retained. For generating 3D images, layer images for compressive light field display between two image planes are calculated. Since the display panel with high pixel density is adopted, high quality 3D images are reconstructed. In addition, image degradation by diffraction between physically stacked display panels can be mitigated. Simple optical configuration of the proposed system is implemented and the feasibility of the proposed method is verified through experiments.
Tiwari, Dileep; Haque, Shafiul; Tiwari, Ram P; Jawed, Arshad; Govender, Thavendran; Kruger, Hendrik G
2017-04-01
A rapid and efficient diagnostic test was developed for the detection of Mycobacterium tuberculosis antigens in serum samples of active tuberculosis (TB) and extrapulmonary TB patients via a liposomal agglutination-based method. A rapid card test has been developed to facilitate the recognition of high-affinity binding rabbit raised purified culture filtrate protein antibodies coupled on the surface of activated liposomal preparation. In the presence of TB antigens, the polyclonal antibodies bound to the liposomal particles demonstrate a visible agglutination reaction. The developed assay was simple, rapid, reliable, sensitive, and specific as a diagnostic test for the detection of antigens in serum samples of clinically confirmed cases of TB within 4-5 minutes' duration. The test was evaluated at different hospitals, medical colleges, and pathology centers, and involved 1483 participants. This investigation was conducted to detect the presence of these antigens during the period of active growth of the microorganism in serum samples for pulmonary TB and processed tissue biopsy for other extrapulmonary TB. Results obtained using this test were compared with acid-fast bacilli smear and culture results. Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application. Copyright © 2015. Published by Elsevier B.V.
Seibold, E; Maier, T; Kostrzewa, M; Zeman, E; Splettstoesser, W
2010-04-01
Francisella tularensis, the causative agent of tularemia, is a potential agent of bioterrorism. The phenotypic discrimination of closely related, but differently virulent, Francisella tularensis subspecies with phenotyping methods is difficult and time-consuming, often producing ambiguous results. As a fast and simple alternative, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) was applied to 50 different strains of the genus Francisella to assess its ability to identify and discriminate between strains according to their designated species and subspecies. Reference spectra from five representative strains of Francisella philomiragia, Francisella tularensis subsp. tularensis, Francisella tularensis subsp. holarctica, Francisella tularensis subsp. mediasiatica, and Francisella tularensis subsp. novicida were established and evaluated for their capability to correctly identify Francisella species and subspecies by matching a collection of spectra from 45 blind-coded Francisella strains against a database containing the five reference spectra and 3,287 spectra from other microorganisms. As a reference method for identification of strains from the genus Francisella, 23S rRNA gene sequencing was used. All strains were correctly identified, with both methods showing perfect agreement at the species level as well as at the subspecies level. The identification of Francisella strains by MALDI-TOF MS and subsequent database matching was reproducible using biological replicates, different culture media, different cultivation times, different serial in vitro passages of the same strain, different preparation protocols, and different mass spectrometers.
Aszyk, Justyna; Kot, Jacek; Tkachenko, Yurii; Woźniak, Michał; Bogucka-Kocka, Anna; Kot-Wasik, Agata
2017-04-15
A simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography-tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F 2α , 8-iso-15(R)-prostaglandin F 2α , 11β-prostaglandin F 2α , 15(R)-prostaglandin F 2α ) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the most reliable markers of oxidative stress in vivo. Validation of method was performed by evaluation of the key analytical parameters such as: matrix effect, analytical curve, trueness, precision, limits of detection and limits of quantification. As a homoscedasticity was not met for analytical data, weighted linear regression was applied in order to improve the accuracy at the lower end points of calibration curve. The detection limits (LODs) ranged from 1.0 to 2.1pg/mL. For plasma samples spiked with the isoprostanes at the level of 50pg/mL, intra-and interday repeatability ranged from 2.1 to 3.5% and 0.1 to 5.1%, respectively. The applicability of the proposed approach has been verified by monitoring of isoprostane isomers level in plasma samples collected from young patients (n=8) subjected to hyperbaric hyperoxia (100% oxygen at 280kPa(a) for 30min) in a multiplace hyperbaric chamber. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kissi, Eric Ofosu; Bawuah, Prince; Silfsten, Pertti; Peiponen, Kai-Erik
2015-03-01
In order to find counterfeit drugs quickly and reliably, we have developed `tape method' a transmission spectroscopic terahertz (THz) measurement technique and compared it with a standard attenuated total reflection (ATR) THz spectroscopic measurement. We used well-known training samples, which include commercial paracetamol and aspirin tablets to check the validity of these two measurement techniques. In this study, the spectral features of some active pharmaceutical ingredients (APIs), such as aspirin and paracetamol are characterized for identification purpose. This work covers a wide THz spectral range namely, 2-18 THz. This proposed simple but novel technique, the tape method, was used for characterizing API and identifying their presence in their dosage forms. By comparing the spectra of the APIs to their dosage forms (powder samples), all distinct fingerprints present in the APIs are also present in their respective dosage forms. The positions of the spectral features obtained with the ATR techniques were akin to that obtained from the tape method. The ATR and the tape method therefore, complement each other. The presence of distinct fingerprints in this spectral range has highlighted the possibility of developing fast THz sensors for the screening of pharmaceuticals. It is worth noting that, the ATR method is applicable to flat faced tablets whereas the tape method is suitable for powders in general (e.g. curved surface tablets that require milling before measurement). Finally, we have demonstrated that ATR techniques can be used to screen counterfeit antimalarial tablets.
ERIC Educational Resources Information Center
Vollmer, Michael; Mollmann, Klaus-Peter
2012-01-01
The recent introduction of inexpensive high-speed cameras offers a new experimental approach to many simple but fast-occurring events in physics. In this paper, the authors present two simple demonstration experiments recorded with high-speed cameras in the fields of gas dynamics and thermal physics. The experiments feature vapour pressure effects…
Simple new test for rapid differentiation of Prototheca wickerhamii from Prototheca zopfii.
Casal, M J; Gutierrez, J
1983-01-01
A simple new test to differentiate Prototheca wickerhamii from Prototheca zopfii by determining susceptibility to clotrimazole is described. A 50-micrograms clotrimazole disk provides a rapid and reliable means of distinguishing P. wickerhamii from P. zopfii. PMID:6630477
ERIC Educational Resources Information Center
Feldt, Leonard S.
2011-01-01
This article presents a simple, computer-assisted method of determining the extent to which increases in reliability increase the power of the "F" test of equality of means. The method uses a derived formula that relates the changes in the reliability coefficient to changes in the noncentrality of the relevant "F" distribution. A readily available…
Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa
2016-04-01
Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.
Reliability of a Shuttle reaction timer
NASA Technical Reports Server (NTRS)
Hays, Russell D.; Mazzocca, Augustus D.; Rashid, Michael; Siconolfi, Steven F.
1992-01-01
Reaction, movement, and task times refer to the times needed to initially respond to a stimulus, make the specific movement, and complete the entire task. This study evaluated the reliability of a simple reaction timer designed to mimic a Space Shuttle task (turning on an overhead switch).
Dykes, Patricia C; Wantland, Dean; Whittenburg, Luann; Lipsitz, Stuart; Saba, Virginia K
2013-01-01
While nursing activities represent a significant proportion of inpatient care, there are no reliable methods for determining nursing costs based on the actual services provided by the nursing staff. Capture of data to support accurate measurement and reporting on the cost of nursing services is fundamental to effective resource utilization. Adopting standard terminologies that support tracking both the quality and the cost of care could reduce the data entry burden on direct care providers. This pilot study evaluated the feasibility of using a standardized nursing terminology, the Clinical Care Classification System (CCC), for developing a reliable costing method for nursing services. Two different approaches are explored; the Relative Value Unit RVU and the simple cost-to-time methods. We found that the simple cost-to-time method was more accurate and more transparent in its derivation than the RVU method and may support a more consistent and reliable approach for costing nursing services.
Rakesh Minocha; Walter C. Shortle; Stephanie L. Long; Subhash C. Minocha
1994-01-01
A fast and reliable method for the extraction of cellular polyamines and major inorganic ions (Ca, Mg, Mn, K, and P) from several plant tissues is described. The method involves repeated freezing and thawing of samples instead of homogenization. The efficiency of extraction of both the polyamines and inorganic ions by these two methods was compared for 10 different...
Strategy for continuous improvement in IC manufacturability, yield, and reliability
NASA Astrophysics Data System (ADS)
Dreier, Dean J.; Berry, Mark; Schani, Phil; Phillips, Michael; Steinberg, Joe; DePinto, Gary
1993-01-01
Continual improvements in yield, reliability and manufacturability measure a fab and ultimately result in Total Customer Satisfaction. A new organizational and technical methodology for continuous defect reduction has been established in a formal feedback loop, which relies on yield and reliability, failed bit map analysis, analytical tools, inline monitoring, cross functional teams and a defect engineering group. The strategy requires the fastest detection, identification and implementation of possible corrective actions. Feedback cycle time is minimized at all points to improve yield and reliability and reduce costs, essential for competitiveness in the memory business. Payoff was a 9.4X reduction in defectivity and a 6.2X improvement in reliability of 256 K fast SRAMs over 20 months.
Ceramic component reliability with the restructured NASA/CARES computer program
NASA Technical Reports Server (NTRS)
Powers, Lynn M.; Starlinger, Alois; Gyekenyesi, John P.
1992-01-01
The Ceramics Analysis and Reliability Evaluation of Structures (CARES) integrated design program on statistical fast fracture reliability and monolithic ceramic components is enhanced to include the use of a neutral data base, two-dimensional modeling, and variable problem size. The data base allows for the efficient transfer of element stresses, temperatures, and volumes/areas from the finite element output to the reliability analysis program. Elements are divided to insure a direct correspondence between the subelements and the Gaussian integration points. Two-dimensional modeling is accomplished by assessing the volume flaw reliability with shell elements. To demonstrate the improvements in the algorithm, example problems are selected from a round-robin conducted by WELFEP (WEakest Link failure probability prediction by Finite Element Postprocessors).
Cyber: A Flexible Deterrent Option
2013-02-14
to come on when they throw a switch and other electrical appliances throughout the house to work without any commercial power interruption. For...power plants this means maintaining the electrical grid and the supervisory control and data acquisition (SCADA) systems at a reliable rate of “99.99999...on the grid.”36 The researchers “simply instructed it to make rapid changes in the electricity cycles that powered the equipment: fast, slow, fast
NASA Technical Reports Server (NTRS)
Carroll, Joseph A.; Alexander, Charles M.
1993-01-01
Design concept promises speed, control, and reliability. Scheme for deploying tether provides for fast, free, and snagless payout and fast, dependable braking. Developed for small, expendable tethers in outer space, scheme also useful in laying transoceanic cables, deploying guidance wires to torpedoes and missiles, paying out rescue lines from ship to ship via rockets, deploying antenna wires, releasing communication and power cables to sonobuoys and expendable bathythermographs, and in reeling out lines from fishing rods.
Robustness of Synchrony in Complex Networks and Generalized Kirchhoff Indices
NASA Astrophysics Data System (ADS)
Tyloo, M.; Coletta, T.; Jacquod, Ph.
2018-02-01
In network theory, a question of prime importance is how to assess network vulnerability in a fast and reliable manner. With this issue in mind, we investigate the response to external perturbations of coupled dynamical systems on complex networks. We find that for specific, nonaveraged perturbations, the response of synchronous states depends on the eigenvalues of the stability matrix of the unperturbed dynamics, as well as on its eigenmodes via their overlap with the perturbation vector. Once averaged over properly defined ensembles of perturbations, the response is given by new graph topological indices, which we introduce as generalized Kirchhoff indices. These findings allow for a fast and reliable method for assessing the specific or average vulnerability of a network against changing operational conditions, faults, or external attacks.
A simple and fast representation space for classifying complex time series
NASA Astrophysics Data System (ADS)
Zunino, Luciano; Olivares, Felipe; Bariviera, Aurelio F.; Rosso, Osvaldo A.
2017-03-01
In the context of time series analysis considerable effort has been directed towards the implementation of efficient discriminating statistical quantifiers. Very recently, a simple and fast representation space has been introduced, namely the number of turning points versus the Abbe value. It is able to separate time series from stationary and non-stationary processes with long-range dependences. In this work we show that this bidimensional approach is useful for distinguishing complex time series: different sets of financial and physiological data are efficiently discriminated. Additionally, a multiscale generalization that takes into account the multiple time scales often involved in complex systems has been also proposed. This multiscale analysis is essential to reach a higher discriminative power between physiological time series in health and disease.
A fast and simple bonding method for low cost microfluidic chip fabrication
NASA Astrophysics Data System (ADS)
Yin, Zhifu; Zou, Helin
2018-01-01
With the development of the microstructure fabrication technique, microfluidic chips are widely used in biological and medical researchers. Future advances in their commercial applications depend on the mass bonding of microfluidic chip. In this study we are presenting a simple, low cost and fast way of bonding microfluidic chips at room temperature. The influence of the bonding pressure on the deformation of the microchannel and adhesive tape was analyzed by numerical simulation. By this method, the microfluidic chip can be fully sealed at low temperature and pressure without using any equipment. The dye water and gas leakage test indicated that the microfluidic chip can be bonded without leakage or block and its bonding strength can up to 0.84 MPa.
Aeroelastic Modeling of Offshore Turbines and Support Structures in Hurricane-Prone Regions (Poster)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damiani, R.
US offshore wind turbines (OWTs) will likely have to contend with hurricanes and the associated loading conditions. Current industry standards do not account for these design load cases (DLCs), thus a new approach is required to guarantee that the OWTs achieve an appropriate level of reliability. In this study, a sequentially coupled aero-hydro-servo-elastic modeling technique was used to address two design approaches: 1.) The ABS (American Bureau of Shipping) approach; and 2.) The Hazard Curve or API (American Petroleum Institute) approach. The former employs IEC partial load factors (PSFs) and 100-yr return-period (RP) metocean events. The latter allows setting PSFsmore » and RP to a prescribed level of system reliability. The 500-yr RP robustness check (appearing in [2] and [3] upcoming editions) is a good indicator of the target reliability for L2 structures. CAE tools such as NREL's FAST and Bentley's' SACS (offshore analysis and design software) can be efficiently coupled to simulate system loads under hurricane DLCs. For this task, we augmented the latest FAST version (v. 8) to include tower aerodynamic drag that cannot be ignored in hurricane DLCs. In this project, a 6 MW turbine was simulated on a typical 4-legged jacket for a mid-Atlantic site. FAST-calculated tower base loads were fed to SACS at the interface level (transition piece); SACS added hydrodynamic and wind loads on the exposed substructure, and calculated mudline overturning moments, and member and joint utilization. Results show that CAE tools can be effectively used to compare design approaches for the design of OWTs in hurricane regions and to achieve a well-balanced design, where reliability levels and costs are optimized.« less
Rodriguez-Molina, Victor M.; Aertsen, Ad; Heck, Detlef H.
2007-01-01
In vivo studies have shown that neurons in the neocortex can generate action potentials at high temporal precision. The mechanisms controlling timing and reliability of action potential generation in neocortical neurons, however, are still poorly understood. Here we investigated the temporal precision and reliability of spike firing in cortical layer V pyramidal cells at near-threshold membrane potentials. Timing and reliability of spike responses were a function of EPSC kinetics, temporal jitter of population excitatory inputs, and of background synaptic noise. We used somatic current injection to mimic population synaptic input events and measured spike probability and spike time precision (STP), the latter defined as the time window (Δt) holding 80% of response spikes. EPSC rise and decay times were varied over the known physiological spectrum. At spike threshold level, EPSC decay time had a stronger influence on STP than rise time. Generally, STP was highest (≤2.45 ms) in response to synchronous compounds of EPSCs with fast rise and decay kinetics. Compounds with slow EPSC kinetics (decay time constants>6 ms) triggered spikes at lower temporal precision (≥6.58 ms). We found an overall linear relationship between STP and spike delay. The difference in STP between fast and slow compound EPSCs could be reduced by incrementing the amplitude of slow compound EPSCs. The introduction of a temporal jitter to compound EPSCs had a comparatively small effect on STP, with a tenfold increase in jitter resulting in only a five fold decrease in STP. In the presence of simulated synaptic background activity, precisely timed spikes could still be induced by fast EPSCs, but not by slow EPSCs. PMID:17389910
First demonstration of the fast-to-slow corrector current shift in the NSLS-II storage ring
NASA Astrophysics Data System (ADS)
Yang, Xi; Tian, Yuke; Yu, Li Hua; Smaluk, Victor
2018-04-01
To realize the full benefits of the high brightness and ultra-small beam sizes of NSLS-II, it is essential that the photon beams are exceedingly stable. In the circumstances of implementing local bumps, changing ID gaps, and long term drifting, the fast orbit feedback (FOFB) requires shifting the fast corrector strengths to the slow correctors to prevent the fast corrector saturation and to make the beam orbit stable in the sub-micron level. As the result, a reliable and precise technique of fast-to-slow corrector strength shift has been developed and tested at NSLS-II. This technique is based on the fast corrector response to the slow corrector change when the FOFB is on. In this article, the shift technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented. The maximum fast corrector current was reduced from greater than 0.45 A to less than 0.04 A with the orbit perturbation within ±1 μm.
USDA-ARS?s Scientific Manuscript database
There is a need for simple surrogate estimates of insulin sensitivity in epidemiological studies of obese youth because the hyperinsulinemic-euglycemic clamp is not feasible on a large scale. Objectives: (i) To examine the triglyceride glucose (TyG) index (Ln[fasting triglycerides (mg/dL)'×'fasting ...
NASA Technical Reports Server (NTRS)
Kershaw, David S.; Prasad, Manoj K.; Beason, J. Douglas
1986-01-01
The Klein-Nishina differential cross section averaged over a relativistic Maxwellian electron distribution is analytically reduced to a single integral, which can then be rapidly evaluated in a variety of ways. A particularly fast method for numerically computing this single integral is presented. This is, to the authors' knowledge, the first correct computation of the Compton scattering kernel.
Design of Water Temperature Control System Based on Single Chip Microcomputer
NASA Astrophysics Data System (ADS)
Tan, Hanhong; Yan, Qiyan
2017-12-01
In this paper, we mainly introduce a multi-function water temperature controller designed with 51 single-chip microcomputer. This controller has automatic and manual water, set the water temperature, real-time display of water and temperature and alarm function, and has a simple structure, high reliability, low cost. The current water temperature controller on the market basically use bimetal temperature control, temperature control accuracy is low, poor reliability, a single function. With the development of microelectronics technology, monolithic microprocessor function is increasing, the price is low, in all aspects of widely used. In the water temperature controller in the application of single-chip, with a simple design, high reliability, easy to expand the advantages of the function. Is based on the appeal background, so this paper focuses on the temperature controller in the intelligent control of the discussion.
A creatinine biosensor based on admittance measurement
NASA Astrophysics Data System (ADS)
Ching, Congo Tak-Shing; Sun, Tai-Ping; Jheng, Deng-Yun; Tsai, Hou-Wei; Shieh, Hsiu-Li
2015-08-01
Regular check of blood creatinine level is very important as it is a measurement of renal function. Therefore, the objective of this study is to develop a simple and reliable creatinine biosensor based on admittance measurement for precise determination of creatinine. The creatinine biosensor was fabricated with creatinine deiminase immobilized on screen-printed carbon electrodes. Admittance measurement at a specific frequency ranges (22.80 - 84.71 Hz) showed that the biosensor has an excellent linear (r2 > 0.95) response range (50 - 250 uM), which covers the normal physiological and pathological ranges of blood creatinine levels. Intraclass correlation coefficient (ICC) showed that the biosensor has excellent reliability and validity (ICC = 0.98). In conclusion, a simple and reliable creatinine biosensor was developed and it is capable of precisely determining blood creatinine levels in both the normal physiological and pathological ranges.
NASA Astrophysics Data System (ADS)
Pérez, Israel; Ángel Hernández Cuevas, José; Trinidad Elizalde Galindo, José
2018-05-01
We designed and developed a desktop AC susceptometer for the characterization of materials. The system consists of a lock-in amplifier, an AC function generator, a couple of coils, a sample holder, a computer system with a designed software in freeware C++ code, and an Arduino card coupled to a Bluetooth module. The Arduino/Bluetooth serial interface allows the user to have a connection to almost any computer and thus avoids the problem of connectivity between the computer and the peripherals, such as the lock-in amplifier and the function generator. The Bluetooth transmitter/receiver used is a commercial device which is robust and fast. These new features reduce the size and increase the versatility of the susceptometer, for it can be used with a simple laptop. To test our instrument, we performed measurements on magnetic materials and show that the system is reliable at both room temperature and cryogenic temperatures (77 K). The instrument is suitable for any physics or engineering laboratory either for research or academic purposes.
Atila, Alptug; Yilmaz, Bilal
2015-01-01
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containing 0.1 M TBACIO4. The well-defined oxidation peak was observed at 1.21 V. The calibration curves were linear for bosentan at the concentration range of 5-40 µg/mL for LSV and 5-35 µg/mL for SWV and DPV methods, respectively. Intra- and inter-day precision values for bosentan were less than 4.92, and accuracy (relative error) was better than 6.29%. The mean recovery of bosentan was 100.7% for pharmaceutical preparations. No interference was found from two tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Tracleer and Diamond tablets as pharmaceutical preparation. PMID:25901151
Accuracy of the adiabatic-impulse approximation for closed and open quantum systems
NASA Astrophysics Data System (ADS)
Tomka, Michael; Campos Venuti, Lorenzo; Zanardi, Paolo
2018-03-01
We study the adiabatic-impulse approximation (AIA) as a tool to approximate the time evolution of quantum states when driven through a region of small gap. Such small-gap regions are a common situation in adiabatic quantum computing and having reliable approximations is important in this context. The AIA originates from the Kibble-Zurek theory applied to continuous quantum phase transitions. The Kibble-Zurek mechanism was developed to predict the power-law scaling of the defect density across a continuous quantum phase transition. Instead, here we quantify the accuracy of the AIA via the trace norm distance with respect to the exact evolved state. As expected, we find that for short times or fast protocols, the AIA outperforms the simple adiabatic approximation. However, for large times or slow protocols, the situation is actually reversed and the AIA provides a worse approximation. Nevertheless, we found a variation of the AIA that can perform better than the adiabatic one. This counterintuitive modification consists in crossing the region of small gap twice. Our findings are illustrated by several examples of driven closed and open quantum systems.
Juillet, Y; Dubois, C; Bintein, F; Dissard, J; Bossée, A
2014-08-01
A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography-mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95%). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention.
Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao
2015-01-01
The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.
NASA Astrophysics Data System (ADS)
Lagos, Soledad R.; Velis, Danilo R.
2018-02-01
We perform the location of microseismic events generated in hydraulic fracturing monitoring scenarios using two global optimization techniques: Very Fast Simulated Annealing (VFSA) and Particle Swarm Optimization (PSO), and compare them against the classical grid search (GS). To this end, we present an integrated and optimized workflow that concatenates into an automated bash script the different steps that lead to the microseismic events location from raw 3C data. First, we carry out the automatic detection, denoising and identification of the P- and S-waves. Secondly, we estimate their corresponding backazimuths using polarization information, and propose a simple energy-based criterion to automatically decide which is the most reliable estimate. Finally, after taking proper care of the size of the search space using the backazimuth information, we perform the location using the aforementioned algorithms for 2D and 3D usual scenarios of hydraulic fracturing processes. We assess the impact of restricting the search space and show the advantages of using either VFSA or PSO over GS to attain significant speed-ups.
Construction and Validation of a Measurement Instrument for Attitudes towards Teamwork.
Mendo-Lázaro, Santiago; Polo-Del-Río, María I; Iglesias-Gallego, Damián; Felipe-Castaño, Elena; León-Del-Barco, Benito
2017-01-01
Cooperative, collaborative learning and other forms of group learning methods are increasingly used in classrooms. Knowing students' attitudes toward teamwork has great value since they influence the students' learning results as well as their social development. So it is necessary to have robust instruments to provide a better understanding of these attitudes and preferences concerning teamwork. Such instruments also help to identify the factors that promote positive or negative attitudes within the context of group activities. Using a sample of 750 first and second year university students studying a degree in Kindergarten, Primary and Social Education, an instrument measuring attitudes toward team learning has been developed. Two distinct factors were obtained through various factorial analyses and structural equations: Academic attitudes and Social and emotional attitudes . Our study reveals that the instrument is both valid and reliable. Its application is both simple and fast and it has important implications for planning teaching and learning activities that contribute to an improvement in attitudes as well as the practice of teaching in the context of learning through teamwork.
Smartphone application for emergency signal detection.
Figueiredo, Isabel N; Leal, Carlos; Pinto, Luís; Bolito, Jason; Lemos, André
2016-09-01
Currently, a number of studies focus on the study and design of new healthcare technologies to improve elderly health and quality of life. Taking advantage of the popularity, portability, and inherent technology of smartphones, we present an emergency application for smartphones, designated as knock-to-panic (KTP). This innovative and novel system enables users to simply hit their devices in order to send an alarm signal to an emergency service. This application is a complete and autonomous emergency system, and can provide an economic, reliable, and unobtrusive method for elderly monitoring or safety protection. Moreover, the simple and fast activation of KTP makes it a viable and potentially superior alternative to traditional ambient assisted living emergency calls. Furthermore, KTP can be further extended to the general population as well and not just be limited for elderly persons. The proposed method is a threshold-based algorithm and is designed to require a low battery power consumption. The evaluation of the performance of the algorithm in collected data indicates that both sensitivity and specificity are above 90%. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Utrera, Mariana; Morcuende, David; Rodríguez-Carpena, Javier-Germán; Estévez, Mario
2011-12-01
Precise methodologies for the routine analysis of particular protein carbonyls are required in order to progress in this topic of increasing interest. The present paper originally describes the application of an improved method for the detection of α-aminoadipic and γ-glutamic semialdehydes in a meat system by using a derivatization procedure with p-amino-benzoic acid (ABA) followed by fluorescent high-performance liquid chromatography (HPLC). The method development comprises i) the description of a simple HPLC program which allows the efficient separation of the ABA and the key standard compounds and ii) the optimization of the procedure for the preparation of a meat sample in order to maximize the fluorescent signal for both protein carbonyls. Furthermore, the suitability of this method is evaluated by applying the technique to porcine burger patties. The present procedure enables an accurate and relatively fast analysis of both semialdehydes in meat samples in which they could play an interesting role as reliable indicators of protein oxidation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Construction and Validation of a Measurement Instrument for Attitudes towards Teamwork
Mendo-Lázaro, Santiago; Polo-del-Río, María I.; Iglesias-Gallego, Damián; Felipe-Castaño, Elena; León-del-Barco, Benito
2017-01-01
Cooperative, collaborative learning and other forms of group learning methods are increasingly used in classrooms. Knowing students’ attitudes toward teamwork has great value since they influence the students’ learning results as well as their social development. So it is necessary to have robust instruments to provide a better understanding of these attitudes and preferences concerning teamwork. Such instruments also help to identify the factors that promote positive or negative attitudes within the context of group activities. Using a sample of 750 first and second year university students studying a degree in Kindergarten, Primary and Social Education, an instrument measuring attitudes toward team learning has been developed. Two distinct factors were obtained through various factorial analyses and structural equations: Academic attitudes and Social and emotional attitudes. Our study reveals that the instrument is both valid and reliable. Its application is both simple and fast and it has important implications for planning teaching and learning activities that contribute to an improvement in attitudes as well as the practice of teaching in the context of learning through teamwork. PMID:28676775
Separation of similar yeast strains by IEF techniques.
Horká, Marie; Růzicka, Filip; Holá, Veronika; Slais, Karel
2009-06-01
Rapid and reliable identification of the etiological agents of infectious diseases, especially species that are hardly distinguishable by routinely used laboratory methods, e.g. Candida albicans from C. dubliniensis, is necessary for early administration of an appropriate therapy. Similarly, the differentiation between biofilm-positive and biofilm-negative yeast strains is necessary for the choice of a therapeutic strategy due to higher resistance of the biofilm-positive strains to antifungals. In this study rapid separation and identification of similar strains of Candida, cells and/or their lysates, based on IEF are outlined. The isoelectric points of the monitored "similar pairs" of Candidas, C. albicans and C. dubliniensis and the biofilm-positive C. parapsilosis, C. tropicalis and their biofilm-negative strains were determined by CIEF with UV detection in the acidic pH gradient. The differences between their isoelectric points were up to 0.3 units of pI. Simultaneously, a fast and a simple technique was developed for the lysis of the outer membrane cell and characteristic fingerprints were found in lysate electrophoreograms and in gels from the capillary or the gel IEF, respectively.
Effective Pb2+ removal from water using nanozerovalent iron stored 10 months
NASA Astrophysics Data System (ADS)
Ahmed, M. A.; Bishay, Samiha T.; Ahmed, Fatma M.; El-Dek, S. I.
2017-10-01
Heavy metal removal from water required reliable and cost-effective considerations, fast separation as well as easy methodology. In this piece of research, nanozerovalent iron (NZVI) was prepared as ideal sorbent for Pb2+ removal. The sample was characterized using X-ray diffraction (XRD), high-resolution transmission electron microscope (HRTEM), and atomic force microscope (AFM-SPM). Batch experiments comprised the effect of pH value and contact time on the adsorption process. The same NZVI was stored for a shelf time (10 months) and the batch experiment was repeated. The outcomes of the investigation assured that NZVI publicized an extraordinary large metal uptake (98%) after a short contact time (10 h). The stored sample revealed the same effectiveness on Pb2+ removal under the same conditions. The results of the physical properties, magnetic susceptibility, and conductance were correlated with the adsorption efficiency. This work offers evidence that these NZVI particles could be potential candidate for Pb2+ removal in large scale, stored for a long time using a simple, green, and cost-effective methodology, and represent an actual feedback in waste water treatment.
Gomez, María R; Sombra, Lorena; Olsina, Roberto A; Martínez, Luis D; Silva, María F
2005-01-01
The present work describes a simple, accurate and rapid method for the separation and simultaneous determination of codeine, diphenhydramine, ephedrine and noscapine present in cough-cold syrup formulations by capillary zone electrophoresis. Factors affecting the separation were the buffer pH and concentration, applied voltage, and presence of additives. Separations were carried out in less than 10 min with a 20 mM sodium tetraborate buffer, pH 8.50. The carrier electrolyte gave baseline separation with good resolution, great reproducibility and accuracy. Calibration plots were linear over at least three orders of magnitude of analyte concentrations, the lower limits of detection being within the range 0.42-1.33 microg ml(-1). Detection was performed by UV absorbance at wavelengths of 205 and 250 nm. Quantification of the components in actual syrup formulations was calculated against the responses of freshly prepared external standard solutions. The method was validated and met all analysis requirements of quality assurance and quality control. The procedure was fast and reliable and commercial pharmaceuticals could be analyzed without prior sample clean-up procedure.
Origin of temperature plateaus in laser-heated diamond anvil cell experiments
NASA Astrophysics Data System (ADS)
Geballe, Zachary M.; Jeanloz, Raymond
2012-06-01
Many high-pressure high-temperature studies using laser-heated diamond cells have documented plateaus in the increase of temperature with increasing laser power or with time. By modeling heat transfer in typical laser-heated diamond anvil cell experiments, we demonstrate that latent heat due to melting or other phase transformation is unlikely to be the source of observed plateaus in any previously published studies, regardless of whether pulsed or continuous lasers were used. Rather, large increases (˜10-fold) in thermal conductivity can explain some of the plateaus, and modest increases in reflectivity (tens of percent) can explain any or all of them. Modeling also shows that the sub-microsecond timescale of heating employed in recent pulsed heating experiments is fast enough compared to heat transport into and through typical insulations, but too slow compared to heat transport into metallic laser absorbers themselves to allow the detection of a large plateau due to latent heat of fusion. Four new designs are suggested for future experiments that could use the simple observation of a latent heat-induced plateau to provide reliable high-pressure melting data.
RP-HPLC determination of water-soluble vitamins in honey.
Ciulu, Marco; Solinas, Silvia; Floris, Ignazio; Panzanelli, Angelo; Pilo, Maria I; Piu, Paola C; Spano, Nadia; Sanna, Gavino
2011-01-15
The assessment and validation of reliable analytical methods for the determination of vitamins in sugar-based matrices (e.g. honey) are still scarcely explored fields of research. This study proposes and fully validates a simple and fast RP-HPLC method for the simultaneous determination of five water-soluble vitamins (vitamin B(2), riboflavin; vitamin B(3), nicotinic acid; vitamin B(5), pantothenic acid; vitamin B(9), folic acid; and vitamin C, ascorbic acid) in honey. The method provides low detection and quantification limits, very good linearity in a large concentration interval, very good precision, and the absence of any bias. It has been successfully applied to 28 honey samples (mainly from Sardinia, Italy) of 12 different botanical origins. While the overall amount of the analytes in the samples is quite low (always below 40 mg kg(-1)), we have observed a marked dependence of some of their concentrations (i.e. vitamin B(3) and vitamin B(5)) and the botanical origin of the honey. This insight might lead to important characterization features for this food item. Copyright © 2010 Elsevier B.V. All rights reserved.
Atila, Alptug; Yilmaz, Bilal
2015-01-01
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containing 0.1 M TBACIO4. The well-defined oxidation peak was observed at 1.21 V. The calibration curves were linear for bosentan at the concentration range of 5-40 µg/mL for LSV and 5-35 µg/mL for SWV and DPV methods, respectively. Intra- and inter-day precision values for bosentan were less than 4.92, and accuracy (relative error) was better than 6.29%. The mean recovery of bosentan was 100.7% for pharmaceutical preparations. No interference was found from two tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Tracleer and Diamond tablets as pharmaceutical preparation.
Rahman, Mohammed M; Balkhoyor, Hasan B; Asiri, Abdullah M
2017-03-01
A nanocomposite (NC) composed of chromium(III)oxide nanomaterials decorated carbon nanotubes (Cr 2 O 3 -CNT NC) was prepared via a simple solution method with reducing agents in an alkaline medium. The Cr 2 O 3 -CNT NC was characterized using ultraviolet-visible (UV/Vs.) spectroscopy, Fourier-transform infrared (FTIR) spectroscopy, energy-dispersive X-ray spectroscopy (XEDS), X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and field-emission scanning electron microscopy (FESEM). The Cr 2 O 3 -CNT composite was deposited on a flat glassy carbon electrode (GCE) with conducting nafion (5%) binders to produce a sensor that exhibited fast response and high selectivity toward 4-methoxyphenol (4MP) in phosphate buffer phase at pH 7. Furthermore, the sensor performance parameters, including the sensitivity, lower detection range, reliability, and reproducibility, ease of integration, long-term stability, and selectivity were investigated in detail. The calibration plot was found to be linear in the concentration range of 0.01 nM-0.1 μM. The sensitivity and detection limit were calculated as 1.4768 μA cm -2 μM -1 and 0.06428 ± 0.0002 nM (at a signal-to-noise ratio of 3), respectively. Thus, it was concluded that the proposed selective and efficient sensor represents a promising approach to effectively detect toxic phenolic compounds in the environment with acceptable and reliable results. Copyright © 2016 Elsevier Ltd. All rights reserved.
Anaya, G; Molina, A; Valera, M; Moreno-Millán, M; Azor, P; Peral-García, P; Demyda-Peyrás, S
2017-08-01
Chromosomal abnormalities in the sex chromosome pair (ECAX and ECAY) are widely associated with reproductive problems in horses. However, a large proportion of these abnormalities remains undiagnosed due to the lack of an affordable diagnostic tool that allows for avoiding karyotyping tests. Hereby, we developed an STR (single-tandem-repeat)-based molecular method to determine the presence of the main sex chromosomal abnormalities in horses in a fast, cheap and reliable way. The frequency of five ECAX-linked (LEX026, LEX003, TKY38, TKY270 and UCDEQ502) and two ECAY-linked (EcaYH12 and SRY) markers was characterized in 261 Purebred Spanish Horses to determine the efficiency of the methodology developed to be used as a chromosomal diagnostic tool. All the microsatellites analyzed were highly polymorphic, with a sizeable number of alleles (polymorphic information content > 0.5). Based on this variability, the methodology showed 100% sensitivity and 99.82% specificity to detect the most important sex chromosomal abnormalities reported in horses (chimerism, Turner's syndrome and sex reversal syndromes). The method was also validated with 100% efficiency in 10 individuals previously diagnosed as chromosomally aberrant. This STR screening panel is an efficient and reliable molecular-cytogenetic tool for the early detection of sex chromosomal abnormalities in equines that could be included in breeding programs to save money, effort and time of veterinary practitioners and breeders. © 2017 Stichting International Foundation for Animal Genetics.
Reliable data storage system design and implementation for acoustic logging while drilling
NASA Astrophysics Data System (ADS)
Hao, Xiaolong; Ju, Xiaodong; Wu, Xiling; Lu, Junqiang; Men, Baiyong; Yao, Yongchao; Liu, Dong
2016-12-01
Owing to the limitations of real-time transmission, reliable downhole data storage and fast ground reading have become key technologies in developing tools for acoustic logging while drilling (LWD). In order to improve the reliability of the downhole storage system in conditions of high temperature, intensive shake and periodic power supply, improvements were made in terms of hardware and software. In hardware, we integrated the storage system and data acquisition control module into one circuit board, to reduce the complexity of the storage process, by adopting the controller combination of digital signal processor and field programmable gate array. In software, we developed a systematic management strategy for reliable storage. Multiple-backup independent storage was employed to increase the data redundancy. A traditional error checking and correction (ECC) algorithm was improved and we embedded the calculated ECC code into all management data and waveform data. A real-time storage algorithm for arbitrary length data was designed to actively preserve the storage scene and ensure the independence of the stored data. The recovery procedure of management data was optimized to realize reliable self-recovery. A new bad block management idea of static block replacement and dynamic page mark was proposed to make the period of data acquisition and storage more balanced. In addition, we developed a portable ground data reading module based on a new reliable high speed bus to Ethernet interface to achieve fast reading of the logging data. Experiments have shown that this system can work stably below 155 °C with a periodic power supply. The effective ground data reading rate reaches 1.375 Mbps with 99.7% one-time success rate at room temperature. This work has high practical application significance in improving the reliability and field efficiency of acoustic LWD tools.
Good cash flow = come in fast, go out slow!
Garvey, Sherill
2002-07-01
The formula for successful cash management in home care is a simple one: The agency must bring cash in as quickly as possible, while keeping expenditures at as low and slow a pace as possible. However, while the formula may be simple, success may be elusive unless agency administrators have a well-thought-out plan to handle cash management.
Saa, Pedro A.; Nielsen, Lars K.
2016-01-01
Motivation: Computation of steady-state flux solutions in large metabolic models is routinely performed using flux balance analysis based on a simple LP (Linear Programming) formulation. A minimal requirement for thermodynamic feasibility of the flux solution is the absence of internal loops, which are enforced using ‘loopless constraints’. The resulting loopless flux problem is a substantially harder MILP (Mixed Integer Linear Programming) problem, which is computationally expensive for large metabolic models. Results: We developed a pre-processing algorithm that significantly reduces the size of the original loopless problem into an easier and equivalent MILP problem. The pre-processing step employs a fast matrix sparsification algorithm—Fast- sparse null-space pursuit (SNP)—inspired by recent results on SNP. By finding a reduced feasible ‘loop-law’ matrix subject to known directionalities, Fast-SNP considerably improves the computational efficiency in several metabolic models running different loopless optimization problems. Furthermore, analysis of the topology encoded in the reduced loop matrix enabled identification of key directional constraints for the potential permanent elimination of infeasible loops in the underlying model. Overall, Fast-SNP is an effective and simple algorithm for efficient formulation of loop-law constraints, making loopless flux optimization feasible and numerically tractable at large scale. Availability and Implementation: Source code for MATLAB including examples is freely available for download at http://www.aibn.uq.edu.au/cssb-resources under Software. Optimization uses Gurobi, CPLEX or GLPK (the latter is included with the algorithm). Contact: lars.nielsen@uq.edu.au Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27559155
A Review on VSC-HVDC Reliability Modeling and Evaluation Techniques
NASA Astrophysics Data System (ADS)
Shen, L.; Tang, Q.; Li, T.; Wang, Y.; Song, F.
2017-05-01
With the fast development of power electronics, voltage-source converter (VSC) HVDC technology presents cost-effective ways for bulk power transmission. An increasing number of VSC-HVDC projects has been installed worldwide. Their reliability affects the profitability of the system and therefore has a major impact on the potential investors. In this paper, an overview of the recent advances in the area of reliability evaluation for VSC-HVDC systems is provided. Taken into account the latest multi-level converter topology, the VSC-HVDC system is categorized into several sub-systems and the reliability data for the key components is discussed based on sources with academic and industrial backgrounds. The development of reliability evaluation methodologies is reviewed and the issues surrounding the different computation approaches are briefly analysed. A general VSC-HVDC reliability evaluation procedure is illustrated in this paper.
Developing a new intelligent system for the diagnosis of tuberculous pleural effusion.
Li, Chengye; Hou, Lingxian; Sharma, Bishundat Yanesh; Li, Huaizhong; Chen, ChengShui; Li, Yuping; Zhao, Xuehua; Huang, Hui; Cai, Zhennao; Chen, Huiling
2018-01-01
In countries with high prevalence of tuberculosis (TB), clinicians often diagnose tuberculous pleural effusion (TPE) by using diagnostic tests, which have not only poor sensitivity, but poor availability as well. The aim of our study is to develop a new artificial intelligence based diagnostic model that is accurate, fast, non-invasive and cost effective to diagnose TPE. It is expected that a tool derived based on the model be installed on simple computer devices (such as smart phones and tablets) and be used by clinicians widely. For this study, data of 140 patients whose clinical signs, routine blood test results, blood biochemistry markers, pleural fluid cell type and count, and pleural fluid biochemical tests' results were prospectively collected into a database. An Artificial intelligence based diagnostic model, which employs moth flame optimization based support vector machine with feature selection (FS-MFO-SVM), is constructed to predict the diagnosis of TPE. The optimal model results in an average of 95% accuracy (ACC), 0.9564 the area under the receiver operating characteristic curve (AUC), 93.35% sensitivity, and 97.57% specificity for FS-MFO-SVM. The proposed artificial intelligence based diagnostic model is found to be highly reliable for diagnosing TPE based on simple clinical signs, blood samples and pleural effusion samples. Therefore, the proposed model can be widely used in clinical practice and further evaluated for use as a substitute of invasive pleural biopsies. Copyright © 2017 Elsevier B.V. All rights reserved.
Kokulnathan, Thangavelu; Kumar, Jeyaraj Vinoth; Chen, Shen-Ming; Karthik, Raj; Elangovan, Arumugam; Muthuraj, Velluchamy
2018-06-01
In the modern world, the contamination of ecosystem by human and veterinary pharmaceutical drugs through the metabolic excretion, improper disposal/industrial waste has been subjected to a hot issue. Therefore, exploitation of exclusive structured material and reliable technique is a necessary task to the precise detection of drugs. With this regards, we made an effort for the fabrication of novel one-dimensional (1D) stannous tungstate nanorods (β-SnW NRs) via simple sonochemical approach and used as an electrochemical sensor for the detection of antipsychotic drug chlorpromazine (CPZ) for the first time. The crystallographic structure, surface topology, elemental compositions and their distributions and ionic states were enquired by different spectroscopic techniques such as XRD, FTIR, SEM, EDS, elemental mapping and XPS analysis. The developed β-SnW NRs/GCE sensor exhibits a rapid and sensitive electrochemical response towards CPZ sensing with wide linear response range (0.01-457 µM), high sensitivity (2.487 µA µM -1 cm -2 ), low detection limit (0.003 µM) and excellent selectivity. Besides, the as-proposed electrochemical sensor was successfully applied to real sample analysis in commercial CPZ drug and biological fluids and the acquired recovery results are quite satisfactory. The proposed sonochemical method for the preparation of β-SnW NRs is low cost, very simple, fast and efficient for sensor applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Tissue-Engineered Fibrin-Based Heart Valve with a Tubular Leaflet Design
Weber, Miriam; Heta, Eriona; Moreira, Ricardo; Gesche, Valentine N.; Schermer, Thomas; Frese, Julia
2014-01-01
The general approach in heart valve tissue engineering is to mimic the shape of the native valve in the attempt to recreate the natural haemodynamics. In this article, we report the fabrication of the first tissue-engineered heart valve (TEHV) based on a tubular leaflet design, where the function of the leaflets of semilunar heart valves is performed by a simple tubular construct sutured along a circumferential line at the root and at three single points at the sinotubular junction. The tubular design is a recent development in pericardial (nonviable) bioprostheses, which has attracted interest because of the simplicity of the construction and the reliability of the implantation technique. Here we push the potential of the concept further from the fabrication and material point of view to realize the tube-in-tube valve: an autologous, living HV with remodelling and growing capability, physiological haemocompatibility, simple to construct and fast to implant. We developed two different fabrication/conditioning procedures and produced fibrin-based constructs embedding cells from the ovine umbilical cord artery according to the two different approaches. Tissue formation was confirmed by histology and immunohistology. The design of the tube-in-tube foresees the possibility of using a textile coscaffold (here demonstrated with a warp-knitted mesh) to achieve enhanced mechanical properties in vision of implantation in the aortic position. The tube-in-tube represents an attractive alternative to the conventional design of TEHVs aiming at reproducing the valvular geometry. PMID:23829551
Kahsay, Getu; Shraim, Fairouz; Villatte, Philippe; Rotger, Jacques; Cassus-Coussère, Céline; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin
2013-03-05
A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C₈ (150 mm × 4.6 mm, 5 μm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 μg/ml and 0.32 μg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities. Copyright © 2012 Elsevier B.V. All rights reserved.
Universal robotic gripper based on the jamming of granular material
Brown, Eric; Rodenberg, Nicholas; Amend, John; Mozeika, Annan; Steltz, Erik; Zakin, Mitchell R.; Lipson, Hod; Jaeger, Heinrich M.
2010-01-01
Gripping and holding of objects are key tasks for robotic manipulators. The development of universal grippers able to pick up unfamiliar objects of widely varying shape and surface properties remains, however, challenging. Most current designs are based on the multifingered hand, but this approach introduces hardware and software complexities. These include large numbers of controllable joints, the need for force sensing if objects are to be handled securely without crushing them, and the computational overhead to decide how much stress each finger should apply and where. Here we demonstrate a completely different approach to a universal gripper. Individual fingers are replaced by a single mass of granular material that, when pressed onto a target object, flows around it and conforms to its shape. Upon application of a vacuum the granular material contracts and hardens quickly to pinch and hold the object without requiring sensory feedback. We find that volume changes of less than 0.5% suffice to grip objects reliably and hold them with forces exceeding many times their weight. We show that the operating principle is the ability of granular materials to transition between an unjammed, deformable state and a jammed state with solid-like rigidity. We delineate three separate mechanisms, friction, suction, and interlocking, that contribute to the gripping force. Using a simple model we relate each of them to the mechanical strength of the jammed state. This advance opens up new possibilities for the design of simple, yet highly adaptive systems that excel at fast gripping of complex objects.
Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.
ERIC Educational Resources Information Center
Youngjohn, James R.; And Others
Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…
Gelman, Hannah; Gruebele, Martin
2014-01-01
Fast folding proteins have been a major focus of computational and experimental study because they are accessible to both techniques: they are small and fast enough to be reasonably simulated with current computational power, but have dynamics slow enough to be observed with specially developed experimental techniques. This coupled study of fast folding proteins has provided insight into the mechanisms which allow some proteins to find their native conformation well less than 1 ms and has uncovered examples of theoretically predicted phenomena such as downhill folding. The study of fast folders also informs our understanding of even “slow” folding processes: fast folders are small, relatively simple protein domains and the principles that govern their folding also govern the folding of more complex systems. This review summarizes the major theoretical and experimental techniques used to study fast folding proteins and provides an overview of the major findings of fast folding research. Finally, we examine the themes that have emerged from studying fast folders and briefly summarize their application to protein folding in general as well as some work that is left to do. PMID:24641816
Development of fast measurements of concentration of NORM U-238 by HPGe
NASA Astrophysics Data System (ADS)
Cha, Seokki; Kim, Siu; Kim, Geehyun
2017-02-01
Naturally Occureed Radioactive Material (NORM) generated from the origin of earth can be found all around us and even people who are not engaged in the work related to radiation have been exposed to unnecessary radiation. This NORM has a potential risk provided that is concentrated or transformed by artificial activities. Likewise, a development of fast measruement method of NORM is emerging to prevent the radiation exposure of the general public and person engaged in the work related to the type of business related thereto who uses the material in which NORM is concentrated or transfromed. Based on such a background, many of countries have tried to manage NORM and carried out regulatory legislation. To effienctly manage NORM, there is need for developing new measurement to quickly and accurately analyze the nuclide and concentration. In this study, development of the fast and reliable measurement was carried out. In addition to confirming the reliability of the fast measurement, we have obtained results that can suggest the possibility of developing another fast measurement. Therefore, as a follow-up, it is possible to develop another fast analytical measurement afterwards. The results of this study will be very useful for the regulatory system to manage NORM. In this study, a review of two indirect measurement methods of NORM U-238 that has used HPGe on the basis of the equilibrium theory of relationships of mother and daughter nuclide at decay-chain of NORM U-238 has been carried out. For comparative study(in order to know reliabily), direct measurement that makes use of alpha spectrometer with complicated pre-processing process was implemented.
Development Of Methodologies Using PhabrOmeter For Fabric Drape Evaluation
NASA Astrophysics Data System (ADS)
Lin, Chengwei
Evaluation of fabric drape is important for textile industry as it reveals the aesthetic and functionality of the cloth and apparel. Although many fabric drape measuring methods have been developed for several decades, they are falling behind the need for fast product development by the industry. To meet the requirement of industries, it is necessary to develop an effective and reliable method to evaluate fabric drape. The purpose of the present study is to determine if PhabrOmeter can be applied to fabric drape evaluation. PhabrOmeter is a fabric sensory performance evaluating instrument which is developed to provide fast and reliable quality testing results. This study was sought to determine the relationship between fabric drape and other fabric attributes. In addition, a series of conventional methods including AATCC standards, ASTM standards and ISO standards were used to characterize the fabric samples. All the data were compared and analyzed with linear correlation method. The results indicate that PhabrOmeter is reliable and effective instrument for fabric drape evaluation. Besides, some effects including fabric structure, testing directions were considered to examine their impact on fabric drape.
Zhang, Xingwu; Wang, Chenxi; Gao, Robert X.; Yan, Ruqiang; Chen, Xuefeng; Wang, Shibin
2016-01-01
Milling vibration is one of the most serious factors affecting machining quality and precision. In this paper a novel hybrid error criterion-based frequency-domain LMS active control method is constructed and used for vibration suppression of milling processes by piezoelectric actuators and sensors, in which only one Fast Fourier Transform (FFT) is used and no Inverse Fast Fourier Transform (IFFT) is involved. The correction formulas are derived by a steepest descent procedure and the control parameters are analyzed and optimized. Then, a novel hybrid error criterion is constructed to improve the adaptability, reliability and anti-interference ability of the constructed control algorithm. Finally, based on piezoelectric actuators and acceleration sensors, a simulation of a spindle and a milling process experiment are presented to verify the proposed method. Besides, a protection program is added in the control flow to enhance the reliability of the control method in applications. The simulation and experiment results indicate that the proposed method is an effective and reliable way for on-line vibration suppression, and the machining quality can be obviously improved. PMID:26751448
Developing of an automation for therapy dosimetry systems by using labview software
NASA Astrophysics Data System (ADS)
Aydin, Selim; Kam, Erol
2018-06-01
Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. Therefore it is very important to provide reliable, accurate and fast calibration services for therapy dosimeters since the radiation dose delivered to a radiotherapy patient is directly related to accuracy and reliability of these devices. In this study, we report the performance of in-house developed computer controlled data acquisition and monitoring software for the commercially available radiation therapy electrometers. LabVIEW® software suite is used to provide reliable, fast and accurate calibration services. The software also collects environmental data such as temperature, pressure and humidity in order to use to use these them in correction factor calculations. By using this software tool, a better control over the calibration process is achieved and the need for human intervention is reduced. This is the first software that can control frequently used dosimeter systems, in radiation thereapy field at hospitals, such as Unidos Webline, Unidos E, Dose-1 and PC Electrometers.
NASA Technical Reports Server (NTRS)
Gyekenyesi, J. P.
1985-01-01
A computer program was developed for calculating the statistical fast fracture reliability and failure probability of ceramic components. The program includes the two-parameter Weibull material fracture strength distribution model, using the principle of independent action for polyaxial stress states and Batdorf's shear-sensitive as well as shear-insensitive crack theories, all for volume distributed flaws in macroscopically isotropic solids. Both penny-shaped cracks and Griffith cracks are included in the Batdorf shear-sensitive crack response calculations, using Griffith's maximum tensile stress or critical coplanar strain energy release rate criteria to predict mixed mode fracture. Weibull material parameters can also be calculated from modulus of rupture bar tests, using the least squares method with known specimen geometry and fracture data. The reliability prediction analysis uses MSC/NASTRAN stress, temperature and volume output, obtained from the use of three-dimensional, quadratic, isoparametric, or axisymmetric finite elements. The statistical fast fracture theories employed, along with selected input and output formats and options, are summarized. An example problem to demonstrate various features of the program is included.
Daikhin, Luba; Ahissar, Merav
2015-07-01
Introducing simple stimulus regularities facilitates learning of both simple and complex tasks. This facilitation may reflect an implicit change in the strategies used to solve the task when successful predictions regarding incoming stimuli can be formed. We studied the modifications in brain activity associated with fast perceptual learning based on regularity detection. We administered a two-tone frequency discrimination task and measured brain activation (fMRI) under two conditions: with and without a repeated reference tone. Although participants could not explicitly tell the difference between these two conditions, the introduced regularity affected both performance and the pattern of brain activation. The "No-Reference" condition induced a larger activation in frontoparietal areas known to be part of the working memory network. However, only the condition with a reference showed fast learning, which was accompanied by a reduction of activity in two regions: the left intraparietal area, involved in stimulus retention, and the posterior superior-temporal area, involved in representing auditory regularities. We propose that this joint reduction reflects a reduction in the need for online storage of the compared tones. We further suggest that this change reflects an implicit strategic shift "backwards" from reliance mainly on working memory networks in the "No-Reference" condition to increased reliance on detected regularities stored in high-level auditory networks.
Xuli, Wu; Weiyi, He; Ji, Kunmei; Wenpu, Wan; Dongsheng, Hu; Hui, Wu; Xinpin, Luo; Zhigang, Liu
2013-03-01
The ingredient declaration on food labels assumes paramount importance in the protection of food-allergic consumers. China has not implemented Food allergen labeling. A gold immunochromatography assay (GICA) was developed using 2 monoclonal antibodies (mAb) against the milk allergen β-lactoglobulin in this study. The GICA was specific for pure milk samples with a sensitivity of 0.2 ng/mL. Milk protein traces extracted from 110 food products were detected by this method. The labels of 106 were confirmed by our GICA method: 57 food samples originally labeled as containing milk were positive for β-lactoglobulin and 49 food samples labeled as not containing milk were negative for β-lactoglobulin. However, 3 food samples falsely labeled as containing milk were found to contain no β-lactoglobulin whereas 1 food sample labeled as not containing milk actually contained β-lactoglobulin. First, these negatives could be because of the addition of a casein fraction. Second, some countries demand that food manufacturers label all ingredients derived from milk as "containing milk" even though the ingredients contain no detectable milk protein by any method. Our GICA method could thus provide a fast and simple method for semiquantitatation of β-lactoglobulin in foods. The present method provides a fast, simple, semiquantitative method for the determination of milk allergens in foods. © 2013 Institute of Food Technologists®
NASA Astrophysics Data System (ADS)
Arantchouk, L.; Houard, A.; Brelet, Y.; Carbonnel, J.; Larour, J.; André, Y.-B.; Mysyrowicz, A.
2013-04-01
We describe a simple, sturdy, and reliable spark gap operating with air at atmospheric pressure and able to switch currents in excess of 10 kA with sub-nanosecond jitter. The spark gap is remotely triggered by a femtosecond laser filament.
Analysis of whisker-toughened CMC structural components using an interactive reliability model
NASA Technical Reports Server (NTRS)
Duffy, Stephen F.; Palko, Joseph L.
1992-01-01
Realizing wider utilization of ceramic matrix composites (CMC) requires the development of advanced structural analysis technologies. This article focuses on the use of interactive reliability models to predict component probability of failure. The deterministic William-Warnke failure criterion serves as theoretical basis for the reliability model presented here. The model has been implemented into a test-bed software program. This computer program has been coupled to a general-purpose finite element program. A simple structural problem is presented to illustrate the reliability model and the computer algorithm.
ZERO: probabilistic routing for deploy and forget Wireless Sensor Networks.
Vilajosana, Xavier; Llosa, Jordi; Pacho, Jose Carlos; Vilajosana, Ignasi; Juan, Angel A; Vicario, Jose Lopez; Morell, Antoni
2010-01-01
As Wireless Sensor Networks are being adopted by industry and agriculture for large-scale and unattended deployments, the need for reliable and energy-conservative protocols become critical. Physical and Link layer efforts for energy conservation are not mostly considered by routing protocols that put their efforts on maintaining reliability and throughput. Gradient-based routing protocols route data through most reliable links aiming to ensure 99% packet delivery. However, they suffer from the so-called "hot spot" problem. Most reliable routes waste their energy fast, thus partitioning the network and reducing the area monitored. To cope with this "hot spot" problem we propose ZERO a combined approach at Network and Link layers to increase network lifespan while conserving reliability levels by means of probabilistic load balancing techniques.
Automated and fast building of three-dimensional RNA structures.
Zhao, Yunjie; Huang, Yangyu; Gong, Zhou; Wang, Yanjie; Man, Jianfen; Xiao, Yi
2012-01-01
Building tertiary structures of non-coding RNA is required to understand their functions and design new molecules. Current algorithms of RNA tertiary structure prediction give satisfactory accuracy only for small size and simple topology and many of them need manual manipulation. Here, we present an automated and fast program, 3dRNA, for RNA tertiary structure prediction with reasonable accuracy for RNAs of larger size and complex topology.
Fast Simulation of the Impact Parameter Calculation of Electrons through Pair Production
NASA Astrophysics Data System (ADS)
Bang, Hyesun; Kweon, MinJung; Huh, Kyoung Bum; Pachmayer, Yvonne
2018-05-01
A fast simulation method is introduced that reduces tremendously the time required for the impact parameter calculation, a key observable in physics analyses of high energy physics experiments and detector optimisation studies. The impact parameter of electrons produced through pair production was calculated considering key related processes using the Bethe-Heitler formula, the Tsai formula and a simple geometric model. The calculations were performed at various conditions and the results were compared with those from full GEANT4 simulations. The computation time using this fast simulation method is 104 times shorter than that of the full GEANT4 simulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Dohoon; Lee, Jinwoo; Kim, Jungbae
2005-12-05
We fabricated a highly sensitive and fast glucose biosensor by simply immobilizing glucose oxidase in mesocellular carbon foam. Due to its unique structure, the MSU-F-C enabled high enzyme loading without serious mass transfer limitation, resulting in high catalytic efficiency. As a result, the glucose biosensor fabricated with MSU-F-C/GOx showed a high sensitivity and fast response. Given these results and the inherent electrical conductivity, we anticipate that MSU-F-C will make a useful matrix for enzyme immobilization in various biocatalytic and electrobiocatalytic applications.
Turbine Performance Optimization Task Status
NASA Technical Reports Server (NTRS)
Griffin, Lisa W.; Turner, James E. (Technical Monitor)
2001-01-01
Capability to optimize for turbine performance and accurately predict unsteady loads will allow for increased reliability, Isp, and thrust-to-weight. The development of a fast, accurate aerodynamic design, analysis, and optimization system is required.
NASA Astrophysics Data System (ADS)
El-Jaat, Majda; Hulley, Michael; Tétreault, Michel
2018-02-01
Despite the broad impact and importance of saltwater intrusion in coastal aquifers, little research has been directed towards forecasting saltwater intrusion in areas where the source of saltwater is uncertain. Saline contamination in inland groundwater supplies is a concern for numerous communities in the southern US including the city of Deltona, Florida. Furthermore, conventional numerical tools for forecasting saltwater contamination are heavily dependent on reliable characterization of the physical characteristics of underlying aquifers, information that is often absent or challenging to obtain. To overcome these limitations, a reliable alternative data-driven model for forecasting salinity in a groundwater supply was developed for Deltona using the fast orthogonal search (FOS) method. FOS was applied on monthly water-demand data and corresponding chloride concentrations at water supply wells. Groundwater salinity measurements from Deltona water supply wells were applied to evaluate the forecasting capability and accuracy of the FOS model. Accurate and reliable groundwater salinity forecasting is necessary to support effective and sustainable coastal-water resource planning and management. The available (27) water supply wells for Deltona were randomly split into three test groups for the purposes of FOS model development and performance assessment. Based on four performance indices (RMSE, RSR, NSEC, and R), the FOS model proved to be a reliable and robust forecaster of groundwater salinity. FOS is relatively inexpensive to apply, is not based on rigorous physical characterization of the water supply aquifer, and yields reliable estimates of groundwater salinity in active water supply wells.
AME - Asteroseismology Made Easy. Estimating stellar properties by using scaled models
NASA Astrophysics Data System (ADS)
Lundkvist, Mia; Kjeldsen, Hans; Silva Aguirre, Victor
2014-06-01
Context. Stellar properties and, in particular stellar radii of exoplanet host stars, are essential for measuring the properties of exoplanets, therefore it is becoming increasingly important to be able to supply reliable stellar radii fast. Grid-modelling is an obvious choice for this, but that only offers a low degree of transparency to non-specialists. Aims: Here we present a new, easy, fast, and transparent method of obtaining stellar properties for stars exhibiting solar-like oscillations. The method, called Asteroseismology Made Easy (AME), can determine stellar masses, mean densities, radii, and surface gravities, as well as estimate ages. We present AME as a visual and powerful tool that could be useful, in particular, in light of the large number of exoplanets being found. Methods: AME consists of a set of figures from which the stellar parameters can be deduced. These figures are made from a grid of stellar evolutionary models that cover masses ranging from 0.7 M⊙ to 1.6 M⊙ in steps of 0.1 M⊙ and metallicities in the interval -0.3 dex ≤ [Fe/H] ≤ +0.3 dex in increments of 0.1 dex. The stellar evolutionary models are computed using the Modules for Experiments in Stellar Astrophysics (MESA) code with simple input physics. Results: We have compared the results from AME with results for three groups of stars: stars with radii determined from interferometry (and measured parallaxes), stars with radii determined from measurements of their parallaxes (and calculated angular diameters), and stars with results based on modelling their individual oscillation frequencies. We find that a comparison of the radii from interferometry to those from AME yields a weighted mean of the fractional differences of just 2%. This is also the level of deviation that we find when we compare the parallax-based radii to the radii determined from AME. Conclusions: The comparison between independently determined stellar parameters and those found using AME show that our method can provide reliable stellar masses, radii, and ages, with median uncertainties in the order of 4%, 2%, and 25%, respectively. http://sac.au.dk/scientific-data/ame
Not so fast! (and not so frugal!): rethinking the recognition heuristic.
Oppenheimer, Daniel M
2003-11-01
The 'fast and frugal' approach to reasoning (Gigerenzer, G., & Todd, P. M. (1999). Simple heuristics that make us smart. New York: Oxford University Press) claims that individuals use non-compensatory strategies in judgment--the idea that only one cue is taken into account in reasoning. The simplest and most important of these heuristics postulates that judgment sometimes relies solely on recognition. However, the studies that have investigated usage of the recognition heuristic have confounded recognition with other cues that could also lead to similar judgments. This paper tests whether mere recognition is actually driving the findings in support of the recognition heuristic. Two studies provide evidence that judgments do not conform to the recognition heuristic when these confounds are accounted for. Implications for the study of simple heuristics are discussed.
Note: High temperature pulsed solenoid valve.
Shen, Wei; Sulkes, Mark
2010-01-01
We have developed a high temperature pulsed solenoid valve with reliable long term operation to at least 400 degrees C. As in earlier published designs, a needle extension sealing a heated orifice is lifted via solenoid actuation; the solenoid is thermally isolated from the heated orifice region. In this new implementation, superior sealing and reliability were attained by choosing a solenoid that produces considerably larger lifting forces on the magnetically actuated plunger. It is this property that facilitates easily attainable sealing and reliability, albeit with some tradeoff in attainable gas pulse durations. The cost of the solenoid valve employed is quite low and the necessary machining quite simple. Our ultimate level of sealing was attained by making a simple modification to the polished seal at the needle tip. The same sealing tip modification could easily be applied to one of the earlier high T valve designs, which could improve the attainability and tightness of sealing for these implementations.
[Effect of fasting-dietary therapy in patients with arterial hypertension and obesity].
Murav'ev, S A; Okonechnikova, N S; Dmitrieva, O A; Makarova, G A
2010-01-01
35 patients with arterial hypertension and obesity against the background of fasting-diet therapy and after 1 and 6 months after treatment conducted daily monitoring of blood pressure, microalbuminuria and glomerular filtration rate, the study of color and contrast sensitivity of retinal eyes. Fasting-diet therapy within 11 days results in reliable reduced daily average AD and stabilization of load pressure indicators; reduction originally pathological microalbuminurii at 18%, increase in the number of patients with normal speed glomerular filtering 48%; improving of eyes function, these changes are saved within 1-6 months after treatment without the using of antihypertensive therapy.
Inexpensive and fast pathogenic bacteria screening using field-effect transistors.
Formisano, Nello; Bhalla, Nikhil; Heeran, Mel; Reyes Martinez, Juana; Sarkar, Amrita; Laabei, Maisem; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Flitsch, Sabine; Estrela, Pedro
2016-11-15
While pathogenic bacteria contribute to a large number of globally important diseases and infections, current clinical diagnosis is based on processes that often involve culturing which can be time-consuming. Therefore, innovative, simple, rapid and low-cost solutions to effectively reduce the burden of bacterial infections are urgently needed. Here we demonstrate a label-free sensor for fast bacterial detection based on metal-oxide-semiconductor field-effect transistors (MOSFETs). The electric charge of bacteria binding to the glycosylated gates of a MOSFET enables quantification in a straightforward manner. We show that the limit of quantitation is 1.9×10(5) CFU/mL with this simple device, which is more than 10,000-times lower than is achieved with electrochemical impedance spectroscopy (EIS) and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-ToF) on the same modified surfaces. Moreover, the measurements are extremely fast and the sensor can be mass produced at trivial cost as a tool for initial screening of pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.
Sun, Hui; Lai, Jia-Ping; Chen, Fang; Zhu, De-Rong
2015-02-01
A simple, fast, and universal suspension polymerization method was used to synthesize the molecularly imprinted microspheres (MIMs) for the topical anesthetic benzocaine (BZC). The desired diameter (10-20 μm) and uniform morphology of the MIMs were obtained easily by changing one or more of the synthesis conditions, including type and amount of surfactant, stirring rate, and ratio of organic to water phase. The MIMs obtained were used as a molecular-imprinting solid-phase-extraction (MISPE) material for extraction of BZC in human serum and fish tissues. The MISPE results revealed that the BZC in these biosamples could be enriched effectively after the MISPE operation. The recoveries of BZC on MIMs cartridges were higher than 90% (n = 3). Finally, an MISPE-HPLC method with UV detection was developed for highly selective extraction and fast detection of trace BZC in human serum and fish tissues. The developed method could also be used for the enrichment and detection of BZC in other complex biosamples.
A simple fast pulse gas valve using a dynamic pressure differential as the primary closing mechanism
NASA Astrophysics Data System (ADS)
Thomas, J. C.; Hwang, D. Q.; Horton, R. D.; Rogers, J. H.; Raman, R.
1993-06-01
In this article we describe a simple fast pulse gas valve developed for use in a plasma discharge experiment. The valve delivers 1017-1019 molecules per pulse varied by changing the voltage on the electromagnetic driver power supply. Valve pulse widths are observed to be less than 300 μs full width at half maximum with a rise time of less than 100 μs resulting in a maximum gas flow rate of ˜1022 molecules per second. An optical transmission technique was used to determine the mechanical opening and closing characteristics of the valve piston. A fast ionization gauge (FIG) was used for diagnosis of the temporal character of the gas pulse while the total gas throughput was determined by measuring the change in pressure per pulse in a small test chamber with a convectron tube gauge. Calibration of the FIG was accomplished by comparing the net change in pressure in a large chamber as measured by the FIG to the net change in pressure in a small test chamber as measured by the convectron tube gauge.
Lax-Friedrichs sweeping scheme for static Hamilton-Jacobi equations
NASA Astrophysics Data System (ADS)
Kao, Chiu Yen; Osher, Stanley; Qian, Jianliang
2004-05-01
We propose a simple, fast sweeping method based on the Lax-Friedrichs monotone numerical Hamiltonian to approximate viscosity solutions of arbitrary static Hamilton-Jacobi equations in any number of spatial dimensions. By using the Lax-Friedrichs numerical Hamiltonian, we can easily obtain the solution at a specific grid point in terms of its neighbors, so that a Gauss-Seidel type nonlinear iterative method can be utilized. Furthermore, by incorporating a group-wise causality principle into the Gauss-Seidel iteration by following a finite group of characteristics, we have an easy-to-implement, sweeping-type, and fast convergent numerical method. However, unlike other methods based on the Godunov numerical Hamiltonian, some computational boundary conditions are needed in the implementation. We give a simple recipe which enforces a version of discrete min-max principle. Some convergence analysis is done for the one-dimensional eikonal equation. Extensive 2-D and 3-D numerical examples illustrate the efficiency and accuracy of the new approach. To our knowledge, this is the first fast numerical method based on discretizing the Hamilton-Jacobi equation directly without assuming convexity and/or homogeneity of the Hamiltonian.
Ponce, Gema; Sanca, Lilica; Mané, Morto; Armada, Ana; Machado, Diana; Vieira, Fina; Gomes, Victor F.; Martins, Elisabete; Colombatti, Raffaella; Riccardi, Fabio; Perdigão, João; Sotero, Joana; Portugal, Isabel; Couto, Isabel; Atouguia, Jorge; Rodrigues, Amabélia; Viveiros, Miguel
2015-01-01
Background This study aimed to evaluate the usefulness of the Xpert MTB/RIF assay for the rapid direct detection of M. tuberculosis complex (MTBC) strains and rifampicin resistance associated mutations in a resource-limited setting such as Guinea-Bissau and its implications in the management of tuberculosis (TB) and drug resistant tuberculosis, complementing the scarce information on resistance and genotypic diversity of MTBC strains in this West African country. Methods and Results This cross-sectional prospective study included 100 consecutive TB patients with positive acid-fast smears at two months of anti-tuberculosis treatment or in a re-treatment situation, between May and December 2012. Resistance to rifampicin was detected using the GeneXpert system and the Xpert MTB/RIF assay. MTBC isolates obtained with the BACTEC MGIT 960 system were tested for susceptibility to first- and second-line anti-tuberculosis drugs. Overall, the prevalence of multidrug-resistant tuberculosis (MDR-TB) was found to be 9 cases. Of these, 67% (6 patients) of confirmed MDR-TB cases had no past history of TB treatment and 33% (3 patients) were previously treated cases. Extensively drug-resistant TB was not found. Molecular typing of the MDR-TB strains revealed recent transmission patterns of imported MDR strains. Conclusions The Xpert MTB/RIF assay was reliable for the detection of rifampicin resistant MTBC strains directly from sputum samples of patients undergoing first-line treatment for two months, being more trustworthy than the simple presence of acid-fast bacilli in the smear. Its implementation is technically simple, does not require specialized laboratory infrastructures and is suitable for resource-limited settings when a regular source of electricity and maintenance is available as well as financial and operation sustainability is guaranteed by the health authorities. A high prevalence of MDR-TB among patients at risk of MDR-TB after two months of first-line treatment was found, in support of the WHO recommendations for its use in the management of this risk group. PMID:26017968
A Bayesian approach to reliability and confidence
NASA Technical Reports Server (NTRS)
Barnes, Ron
1989-01-01
The historical evolution of NASA's interest in quantitative measures of reliability assessment is outlined. The introduction of some quantitative methodologies into the Vehicle Reliability Branch of the Safety, Reliability and Quality Assurance (SR and QA) Division at Johnson Space Center (JSC) was noted along with the development of the Extended Orbiter Duration--Weakest Link study which will utilize quantitative tools for a Bayesian statistical analysis. Extending the earlier work of NASA sponsor, Richard Heydorn, researchers were able to produce a consistent Bayesian estimate for the reliability of a component and hence by a simple extension for a system of components in some cases where the rate of failure is not constant but varies over time. Mechanical systems in general have this property since the reliability usually decreases markedly as the parts degrade over time. While they have been able to reduce the Bayesian estimator to a simple closed form for a large class of such systems, the form for the most general case needs to be attacked by the computer. Once a table is generated for this form, researchers will have a numerical form for the general solution. With this, the corresponding probability statements about the reliability of a system can be made in the most general setting. Note that the utilization of uniform Bayesian priors represents a worst case scenario in the sense that as researchers incorporate more expert opinion into the model, they will be able to improve the strength of the probability calculations.
Eaton, T; Young, P; Fergusson, W; Garrett, J E; Kolbe, J
2005-04-01
The negative impact of chronic obstructive pulmonary disease (COPD) on health-related quality of life (HRQL) is substantial. Measurement of HRQL is increasingly advocated in clinical practice; traditional outcome measures such as lung function are poorly responsive. However many HRQL tools are not user-friendly in the clinic setting. Hence HRQL is often neglected. The Dartmouth Cooperative Functional Assessment Charts (COOP) have the requisite attributes of a tool suitable for routine clinical practice: they are simple, reliable, quick and easy to perform and score and well accepted. We aimed to determine the reliability, validity and responsiveness of the COOP in patients with significant COPD. HRQL was assessed during a prospective, randomised, placebo-controlled, double-blind, 12 week cross-over interventional study of ambulatory oxygen in patients (n = 50) with COPD. Test-retest reliability of the COOP domains was only modest however it was measured over a 2 month period. Significant correlations ranging between 0.4 and 0.8 were observed between all comparable domains of the COOP and the Medical Outcomes Study 36-item Short-form Health Survey, Chronic Respiratory Questionnaire (CRQ) and Hospital Anxiety and Depression (HAD) scale. Following ambulatory oxygen significant improvements were noted in all CRQ and HAD domains. Several domains of the generic SF-36 (role emotional, social functioning, role-physical) showed significant improvements. Comparable domains of the COOP (social activities, feelings) also showed significant improvements. The COOP change in health domain improved very significantly. The COOP is a simple, reliable HRQL tool which proved valid and responsive in our study population of COPD patients and may have a valuable role in routine clinical practice.
1988-08-01
exchanged between the cells, thus requiring existence of fast , high capacity, high availability communication channels. The same arguments indicate...mininet - loss of a cell - intermittent communications failure in the maxinet - partitioning of the maxinet or the mininet o Query decomposition. 3.3...take place. A new sequencer is selected by the timeout mechanism described above. This process Pj must set its priority to 0 in order to ensure fast
NASA Astrophysics Data System (ADS)
Hameed, M.; Demirel, M. C.; Moradkhani, H.
2015-12-01
Global Sensitivity Analysis (GSA) approach helps identify the effectiveness of model parameters or inputs and thus provides essential information about the model performance. In this study, the effects of the Sacramento Soil Moisture Accounting (SAC-SMA) model parameters, forcing data, and initial conditions are analysed by using two GSA methods: Sobol' and Fourier Amplitude Sensitivity Test (FAST). The simulations are carried out over five sub-basins within the Columbia River Basin (CRB) for three different periods: one-year, four-year, and seven-year. Four factors are considered and evaluated by using the two sensitivity analysis methods: the simulation length, parameter range, model initial conditions, and the reliability of the global sensitivity analysis methods. The reliability of the sensitivity analysis results is compared based on 1) the agreement between the two sensitivity analysis methods (Sobol' and FAST) in terms of highlighting the same parameters or input as the most influential parameters or input and 2) how the methods are cohered in ranking these sensitive parameters under the same conditions (sub-basins and simulation length). The results show the coherence between the Sobol' and FAST sensitivity analysis methods. Additionally, it is found that FAST method is sufficient to evaluate the main effects of the model parameters and inputs. Another conclusion of this study is that the smaller parameter or initial condition ranges, the more consistency and coherence between the sensitivity analysis methods results.
Ciresi, Alessandro; Cicciò, Floriana; Radellini, Stefano; Giordano, Carla
2016-08-01
GH treatment (GHT) can lead to glucose metabolism impairment through decreased insulin sensitivity and impaired pancreatic β-cell function, which are the two key components of the pathogenesis of diabetes. Therefore, in addition to insulin sensitivity, during GHT it is very important to perform a reliable evaluation of insulin secretion. However, conflicting data exist regarding the insulin secretion in children during GHT. C-peptide provides a more reliable estimate of β-cell function than insulin, but few studies evaluated it during GHT. Our aim was to assess the usefulness of C-peptide in the evaluation of insulin secretion in GH deficiency (GHD) children. In 48 GHD children, at baseline and after 12 and 24months of GHT, and in 56 healthy subjects we evaluated fasting and glucagon-stimulated (AUCCpep) C-peptide levels in addition to other commonly used secretion indexes, such as fasting and oral glucose tolerance test-stimulated insulin levels (AUCINS), Homa-β, and insulinogenic index. The main outcomes were the change in C-peptide during GHT and its correlation with the auxological and hormonal parameters. At baseline GHD children showed a significant lower AUCCpep (p=0.006), while no difference was found for the other indexes. Both fasting C-peptide (beta 0.307, p=0.016) and AUCCpep (beta 0.379, p=0.002) were independently correlated with IGF-I SDS, while no correlation was found for all other indexes. After 12months an increase in Homa-β (p<0.001), fasting C-peptide (p=0.002) and AUCCpep (p<0.001) was found. At multivariate analysis, only fasting C-peptide (beta 0.783, p=0.001) and AUCCpep (beta 0.880, p<0.001) were independently correlated with IGF-I SDS. C-peptide, rather than the insulin-derived indexes, has proved to be the most useful marker of insulin secretion correlated to IGF-I levels in GHD children. Therefore, we suggest the use of glucagon test both as diagnostic test for the GH assessment and as a useful tool for the evaluation of insulin secretion during GHT in children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hierarchical modeling for reliability analysis using Markov models. B.S./M.S. Thesis - MIT
NASA Technical Reports Server (NTRS)
Fagundo, Arturo
1994-01-01
Markov models represent an extremely attractive tool for the reliability analysis of many systems. However, Markov model state space grows exponentially with the number of components in a given system. Thus, for very large systems Markov modeling techniques alone become intractable in both memory and CPU time. Often a particular subsystem can be found within some larger system where the dependence of the larger system on the subsystem is of a particularly simple form. This simple dependence can be used to decompose such a system into one or more subsystems. A hierarchical technique is presented which can be used to evaluate these subsystems in such a way that their reliabilities can be combined to obtain the reliability for the full system. This hierarchical approach is unique in that it allows the subsystem model to pass multiple aggregate state information to the higher level model, allowing more general systems to be evaluated. Guidelines are developed to assist in the system decomposition. An appropriate method for determining subsystem reliability is also developed. This method gives rise to some interesting numerical issues. Numerical error due to roundoff and integration are discussed at length. Once a decomposition is chosen, the remaining analysis is straightforward but tedious. However, an approach is developed for simplifying the recombination of subsystem reliabilities. Finally, a real world system is used to illustrate the use of this technique in a more practical context.
Simple, Inexpensive, and Rapid Way to Produce Bacillus subtilis Spores for the Guthrie Bioassay
Franklin, Martha L.; Clark, William A.
1981-01-01
Esculin agar has been found to be a simple, inexpensive, rapid, and reliable means to promote production of spores of inhibitor-sensitive clones of Bacillus subtilis strains ATCC 6051 and 6633 for use in the Guthrie bioassay screening tests for genetic metabolic disorders. Images PMID:6790564
Spatial surplus production modeling of Atlantic tunas and billfish.
Carruthers, Thomas R; McAllister, Murdoch K; Taylor, Nathan G
2011-10-01
We formulate and simulation-test a spatial surplus production model that provides a basis with which to undertake multispecies, multi-area, stock assessment. Movement between areas is parameterized using a simple gravity model that includes a "residency" parameter that determines the degree of stock mixing among areas. The model is deliberately simple in order to (1) accommodate nontarget species that typically have fewer available data and (2) minimize computational demand to enable simulation evaluation of spatial management strategies. Using this model, we demonstrate that careful consideration of spatial catch and effort data can provide the basis for simple yet reliable spatial stock assessments. If simple spatial dynamics can be assumed, tagging data are not required to reliably estimate spatial distribution and movement. When applied to eight stocks of Atlantic tuna and billfish, the model tracks regional catch data relatively well by approximating local depletions and exchange among high-abundance areas. We use these results to investigate and discuss the implications of using spatially aggregated stock assessment for fisheries in which the distribution of both the population and fishing vary over time.
Mid-infrared spectroscopy in skin cancer cell type identification
NASA Astrophysics Data System (ADS)
Kastl, Lena; Kemper, Björn; Lloyd, Gavin R.; Nallala, Jayakrupakar; Stone, Nick; Naranjo, Valery; Penaranda, Francisco; Schnekenburger, Jürgen
2017-07-01
Mid infrared spectroscopy samples were developed for the analysis of skin tumor cell types and three dimensional tissue phantoms towards the application of midIR spectroscopy for fast and reliable skin cancer diagnostics.
A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.
Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste
2018-02-01
To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV% < 10%), whatever the considered method. The mechanical variables ([Formula: see text], [Formula: see text]) measured with the 2 methods and all the variables extrapolated from the F-v relationships were strongly correlated (r 2 > .80, P < .001). The practical differences between the methods for the extrapolated mechanical parameters were all <5%, indicating very probably no differences. The findings suggest that the simple computation method used here provides valid and reliable information on force and velocity produced during ballistic bench press, in line with that observed in laboratory conditions. This simple method is thus a practical tool, requiring only 3 simple parameters (upper-limb mass, barbell flight height, and push-off distance).
Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.
Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît
2017-01-01
To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV <1.0%. These results suggest that the simple method presented here is valid and reliable for computing CMJ force, velocity, power, and F-v profiles in athletes and could be used in practice under field conditions when body mass, push-off distance, and jump height are known.
Integrated Multiscale Modeling of Molecular Computing Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregory Beylkin
2012-03-23
Significant advances were made on all objectives of the research program. We have developed fast multiresolution methods for performing electronic structure calculations with emphasis on constructing efficient representations of functions and operators. We extended our approach to problems of scattering in solids, i.e. constructing fast algorithms for computing above the Fermi energy level. Part of the work was done in collaboration with Robert Harrison and George Fann at ORNL. Specific results (in part supported by this grant) are listed here and are described in greater detail. (1) We have implemented a fast algorithm to apply the Green's function for themore » free space (oscillatory) Helmholtz kernel. The algorithm maintains its speed and accuracy when the kernel is applied to functions with singularities. (2) We have developed a fast algorithm for applying periodic and quasi-periodic, oscillatory Green's functions and those with boundary conditions on simple domains. Importantly, the algorithm maintains its speed and accuracy when applied to functions with singularities. (3) We have developed a fast algorithm for obtaining and applying multiresolution representations of periodic and quasi-periodic Green's functions and Green's functions with boundary conditions on simple domains. (4) We have implemented modifications to improve the speed of adaptive multiresolution algorithms for applying operators which are represented via a Gaussian expansion. (5) We have constructed new nearly optimal quadratures for the sphere that are invariant under the icosahedral rotation group. (6) We obtained new results on approximation of functions by exponential sums and/or rational functions, one of the key methods that allows us to construct separated representations for Green's functions. (7) We developed a new fast and accurate reduction algorithm for obtaining optimal approximation of functions by exponential sums and/or their rational representations.« less
NASA Astrophysics Data System (ADS)
Jiang, Cheng-Yong; Sun, Shi-Hao; Zhang, Qi-Dong; Liu, Jun-Hui; Zhang, Jian-Xun; Zong, Yong-Li; Xie, Jian-Ping
2013-03-01
A method with atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) was developed and applied to direct analysis of Environmental Tobacco Smoke (ETS), using 3-ethenylpyridine (3-EP) as a vapour-phase marker. In this study, the ion source of APCI-MS/MS was modified and direct analysis of gas sample was achieved by the modified instrument. ETS samples were directly introduced, via an atmospheric pressure inlet, into the APCI source. Ionization was carried out in positive-ion APCI mode and 3-EP was identified by both full scan mode and daughter scan mode. Quantification of 3-EP was performed by multiple reaction monitoring (MRM) mode. The calibration curve was obtained in the range of 1-250 ng L-1 with a satisfactory regression coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.5 ng L-1 and 1.6 ng L-1, respectively. The precision of the method, calculated as relative standard deviation (RSD), was characterized by repeatability (RSD 3.92%) and reproducibility (RSD 4.81%), respectively. In real-world ETS samples analysis, compared with the conventional GC-MS method, the direct APCI-MS/MS has shown better reliability and practicability in the determination of 3-EP at trace level. The developed method is simple, fast, sensitive and repeatable; furthermore, it could provide an alternative way for the determination of other volatile pollutants in ambient air at low levels.
COLD-PCR enriches low-level variant DNA sequences and increases the sensitivity of genetic testing.
Castellanos-Rizaldos, Elena; Milbury, Coren A; Guha, Minakshi; Makrigiorgos, G Mike
2014-01-01
Detection of low-level mutations is important for cancer biomarker and therapy targets discovery, but reliable detection remains a technical challenge. The newly developed method of CO-amplification at Lower Denaturation temperature PCR (COLD-PCR) helps to circumvent this issue. This PCR-based technology preferentially enriches minor known or unknown variants present in samples with a high background of wild type DNA which often hampers the accurate identification of these minority alleles. This is a simple process that consists of lowering the temperature at the denaturation step during the PCR-cycling protocol (critical denaturation temperature, T c) and inducing DNA heteroduplexing during an intermediate step. COLD-PCR in its simplest forms does not need additional reagents or specific instrumentation and thus, can easily replace conventional PCR and at the same time improve the mutation detection sensitivity limit of downstream technologies. COLD-PCR can be applied in two basic formats: fast-COLD-PCR that can enrich T m-reducing mutations and full-COLD-PCR that can enrich all mutations, though it requires an intermediate cross-hybridization step that lengthens the thermocycling program. An improved version of full-COLD-PCR (improved and complete enrichment, ice-COLD-PCR) has also been described. Finally, most recently, we developed yet another form of COLD-PCR, temperature-tolerant-COLD-PCR, which gradually increases the denaturation temperature during the COLD-PCR reaction, enriching diverse targets using a single cycling program. This report describes practical considerations for application of fast-, full-, ice-, and temperature-tolerant-COLD-PCR for enrichment of mutations prior to downstream screening.
Kang, Lin; Li, Nan; Li, Ping; Zhou, Yang; Gao, Shan; Gao, Hongwei; Xin, Wenwen; Wang, Jinglin
2017-04-01
Salmonella can cause global foodborne illnesses in humans and many animals. The current diagnostic gold standard used for detecting Salmonella infection is microbiological culture followed by serological confirmation tests. However, these methods are complicated and time-consuming. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis offers some advantages in rapid identification, for example, simple and fast sample preparation, fast and automated measurement, and robust and reliable identification up to genus and species levels, possibly even to the strain level. In this study, we established a reference database for species identification using whole-cell MALDI-TOF MS; the database consisted of 12 obtained main spectra of the Salmonella culture collection strains belonged to seven serotypes. Eighty-two clinical isolates of Salmonella were identified using established database, and partial 16S rDNA gene sequencing and serological method were used as comparison. We found that MALDI-TOF mass spectrometry provided high accuracy in identification of Salmonella at species level but was limited to type or subtype Salmonella serovars. We also tried to find serovar-specific biomarkers and failed. Our study demonstrated that (a) MALDI-TOF MS was suitable for identification of Salmonella at species level with high accuracy and (b) that MALDI-TOF MS method presented in this study was not useful for serovar assignment of Salmonella currently, because of its low matching with serological method and (c) MALDI-TOF MS method presented in this study was not suitable to subtype S. typhimurium because of its low discriminatory ability.
Intelligent Mobile Autonomous System
1987-01-01
used intermittently , and each of them characterizes the level of generalization. One cannot discern any another point within the tile, this is a...traversability space is not fast enough to be considered for actual control application. Alternatives to limit the computation time include (1) increasing the...error. (b) It must be concise and easy to "compute". In other words there must exist simple, fast procedures for instandating the "words" or "sentences
High performance pipelined multiplier with fast carry-save adder
NASA Technical Reports Server (NTRS)
Wu, Angus
1990-01-01
A high-performance pipelined multiplier is described. Its high performance results from the fast carry-save adder basic cell which has a simple structure and is suitable for the Gate Forest semi-custom environment. The carry-save adder computes the sum and carry within two gate delay. Results show that the proposed adder can operate at 200 MHz for a 2-micron CMOS process; better performance is expected in a Gate Forest realization.
Fast temporal correlation between hard X-ray and ultraviolet continuum brightenings
NASA Technical Reports Server (NTRS)
Machado, Marcos E.; Mauas, Pablo J.
1986-01-01
Recent Solar Maximum Mission (SMM) observations have shown fast and simultaneous increases in hard X-rays (HXR, E25 keV) and ultraviolet continuum (UVC, lambda lambda approx. equals 1600 and 1388 A) radiation. A simple and natural explanation is given for this phenomenon to happen, which does not involve extreme conditions for energy transport processes, and confirms earlier results on the effect of XUV photoionization in the solar atmosphere.
CARES - CERAMICS ANALYSIS AND RELIABILITY EVALUATION OF STRUCTURES
NASA Technical Reports Server (NTRS)
Nemeth, N. N.
1994-01-01
The beneficial properties of structural ceramics include their high-temperature strength, light weight, hardness, and corrosion and oxidation resistance. For advanced heat engines, ceramics have demonstrated functional abilities at temperatures well beyond the operational limits of metals. This is offset by the fact that ceramic materials tend to be brittle. When a load is applied, their lack of significant plastic deformation causes the material to crack at microscopic flaws, destroying the component. CARES calculates the fast-fracture reliability or failure probability of macroscopically isotropic ceramic components. These components may be subjected to complex thermomechanical loadings. The program uses results from a commercial structural analysis program (MSC/NASTRAN or ANSYS) to evaluate component reliability due to inherent surface and/or volume type flaws. A multiple material capability allows the finite element model reliability to be a function of many different ceramic material statistical characterizations. The reliability analysis uses element stress, temperature, area, and volume output, which are obtained from two dimensional shell and three dimensional solid isoparametric or axisymmetric finite elements. CARES utilizes the Batdorf model and the two-parameter Weibull cumulative distribution function to describe the effects of multi-axial stress states on material strength. The shear-sensitive Batdorf model requires a user-selected flaw geometry and a mixed-mode fracture criterion. Flaws intersecting the surface and imperfections embedded in the volume can be modeled. The total strain energy release rate theory is used as a mixed mode fracture criterion for co-planar crack extension. Out-of-plane crack extension criteria are approximated by a simple equation with a semi-empirical constant that can model the maximum tangential stress theory, the minimum strain energy density criterion, the maximum strain energy release rate theory, or experimental results. For comparison, Griffith's maximum tensile stress theory, the principle of independent action, and the Weibull normal stress averaging models are also included. Weibull material strength parameters, the Batdorf crack density coefficient, and other related statistical quantities are estimated from four-point bend bar or uniform uniaxial tensile specimen fracture strength data. Parameter estimation can be performed for single or multiple failure modes by using the least-squares analysis or the maximum likelihood method. A more limited program, CARES/PC (COSMIC number LEW-15248) runs on a personal computer and estimates ceramic material properties from three-point bend bar data. CARES/PC does not perform fast fracture reliability estimation. CARES is written in FORTRAN 77 and has been implemented on DEC VAX series computers under VMS and on IBM 370 series computers under VM/CMS. On a VAX, CARES requires 10Mb of main memory. Five MSC/NASTRAN example problems and two ANSYS example problems are provided. There are two versions of CARES supplied on the distribution tape, CARES1 and CARES2. CARES2 contains sub-elements and CARES1 does not. CARES is available on a 9-track 1600 BPI VAX FILES-11 format magnetic tape (standard media) or in VAX BACKUP format on a TK50 tape cartridge. The program requires a FORTRAN 77 compiler and about 12Mb memory. CARES was developed in 1990. DEC, VAX and VMS are trademarks of Digital Equipment Corporation. IBM 370 is a trademark of International Business Machines. MSC/NASTRAN is a trademark of MacNeal-Schwendler Corporation. ANSYS is a trademark of Swanson Analysis Systems, Inc.
Portion Size Versus Serving Size
... Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering the Menu Ordering Your Meal Eating Fast ... don’t know what a healthy portion is. Restaurants offer extras like breads, chips and other appetizers ...
Assessment of the impact of the scanner-related factors on brain morphometry analysis with Brainvisa
2011-01-01
Background Brain morphometry is extensively used in cross-sectional studies. However, the difference in the estimated values of the morphometric measures between patients and healthy subjects may be small and hence overshadowed by the scanner-related variability, especially with multicentre and longitudinal studies. It is important therefore to investigate the variability and reliability of morphometric measurements between different scanners and different sessions of the same scanner. Methods We assessed the variability and reliability for the grey matter, white matter, cerebrospinal fluid and cerebral hemisphere volumes as well as the global sulcal index, sulcal surface and mean geodesic depth using Brainvisa. We used datasets obtained across multiple MR scanners at 1.5 T and 3 T from the same groups of 13 and 11 healthy volunteers, respectively. For each morphometric measure, we conducted ANOVA analysis and verified whether the estimated values were significantly different across different scanners or different sessions of the same scanner. The between-centre and between-visit reliabilities were estimated from their contribution to the total variance, using a random-effects ANOVA model. To estimate the main processes responsible for low reliability, the results of brain segmentation were compared to those obtained using FAST within FSL. Results In a considerable number of cases, the main effects of both centre and visit factors were found to be significant. Moreover, both between-centre and between-visit reliabilities ranged from poor to excellent for most morphometric measures. A comparison between segmentation using Brainvisa and FAST revealed that FAST improved the reliabilities for most cases, suggesting that morphometry could benefit from improving the bias correction. However, the results were still significantly different across different scanners or different visits. Conclusions Our results confirm that for morphometry analysis with the current version of Brainvisa using data from multicentre or longitudinal studies, the scanner-related variability must be taken into account and where possible should be corrected for. We also suggest providing some flexibility to Brainvisa for a step-by-step analysis of the robustness of this package in terms of reproducibility of the results by allowing the bias corrected images to be imported from other packages and bias correction step be skipped, for example. PMID:22189342
Essa, Khalid S
2014-01-01
A new fast least-squares method is developed to estimate the shape factor (q-parameter) of a buried structure using normalized residual anomalies obtained from gravity data. The problem of shape factor estimation is transformed into a problem of finding a solution of a non-linear equation of the form f(q) = 0 by defining the anomaly value at the origin and at different points on the profile (N-value). Procedures are also formulated to estimate the depth (z-parameter) and the amplitude coefficient (A-parameter) of the buried structure. The method is simple and rapid for estimating parameters that produced gravity anomalies. This technique is used for a class of geometrically simple anomalous bodies, including the semi-infinite vertical cylinder, the infinitely long horizontal cylinder, and the sphere. The technique is tested and verified on theoretical models with and without random errors. It is also successfully applied to real data sets from Senegal and India, and the inverted-parameters are in good agreement with the known actual values.
Bieri, Michael; d'Auvergne, Edward J; Gooley, Paul R
2011-06-01
Investigation of protein dynamics on the ps-ns and μs-ms timeframes provides detailed insight into the mechanisms of enzymes and the binding properties of proteins. Nuclear magnetic resonance (NMR) is an excellent tool for studying protein dynamics at atomic resolution. Analysis of relaxation data using model-free analysis can be a tedious and time consuming process, which requires good knowledge of scripting procedures. The software relaxGUI was developed for fast and simple model-free analysis and is fully integrated into the software package relax. It is written in Python and uses wxPython to build the graphical user interface (GUI) for maximum performance and multi-platform use. This software allows the analysis of NMR relaxation data with ease and the generation of publication quality graphs as well as color coded images of molecular structures. The interface is designed for simple data analysis and management. The software was tested and validated against the command line version of relax.
Essa, Khalid S.
2013-01-01
A new fast least-squares method is developed to estimate the shape factor (q-parameter) of a buried structure using normalized residual anomalies obtained from gravity data. The problem of shape factor estimation is transformed into a problem of finding a solution of a non-linear equation of the form f(q) = 0 by defining the anomaly value at the origin and at different points on the profile (N-value). Procedures are also formulated to estimate the depth (z-parameter) and the amplitude coefficient (A-parameter) of the buried structure. The method is simple and rapid for estimating parameters that produced gravity anomalies. This technique is used for a class of geometrically simple anomalous bodies, including the semi-infinite vertical cylinder, the infinitely long horizontal cylinder, and the sphere. The technique is tested and verified on theoretical models with and without random errors. It is also successfully applied to real data sets from Senegal and India, and the inverted-parameters are in good agreement with the known actual values. PMID:25685472
Examples of Nonconservatism in the CARE 3 Program
NASA Technical Reports Server (NTRS)
Dotson, Kelly J.
1988-01-01
This paper presents parameter regions in the CARE 3 (Computer-Aided Reliability Estimation version 3) computer program where the program overestimates the reliability of a modeled system without warning the user. Five simple models of fault-tolerant computer systems are analyzed; and, the parameter regions where reliability is overestimated are given. The source of the error in the reliability estimates for models which incorporate transient fault occurrences was not readily apparent. However, the source of much of the error for models with permanent and intermittent faults can be attributed to the choice of values for the run-time parameters of the program.
Complementary Reliability-Based Decodings of Binary Linear Block Codes
NASA Technical Reports Server (NTRS)
Fossorier, Marc P. C.; Lin, Shu
1997-01-01
This correspondence presents a hybrid reliability-based decoding algorithm which combines the reprocessing method based on the most reliable basis and a generalized Chase-type algebraic decoder based on the least reliable positions. It is shown that reprocessing with a simple additional algebraic decoding effort achieves significant coding gain. For long codes, the order of reprocessing required to achieve asymptotic optimum error performance is reduced by approximately 1/3. This significantly reduces the computational complexity, especially for long codes. Also, a more efficient criterion for stopping the decoding process is derived based on the knowledge of the algebraic decoding solution.
Maximum Entropy Discrimination Poisson Regression for Software Reliability Modeling.
Chatzis, Sotirios P; Andreou, Andreas S
2015-11-01
Reliably predicting software defects is one of the most significant tasks in software engineering. Two of the major components of modern software reliability modeling approaches are: 1) extraction of salient features for software system representation, based on appropriately designed software metrics and 2) development of intricate regression models for count data, to allow effective software reliability data modeling and prediction. Surprisingly, research in the latter frontier of count data regression modeling has been rather limited. More specifically, a lack of simple and efficient algorithms for posterior computation has made the Bayesian approaches appear unattractive, and thus underdeveloped in the context of software reliability modeling. In this paper, we try to address these issues by introducing a novel Bayesian regression model for count data, based on the concept of max-margin data modeling, effected in the context of a fully Bayesian model treatment with simple and efficient posterior distribution updates. Our novel approach yields a more discriminative learning technique, making more effective use of our training data during model inference. In addition, it allows of better handling uncertainty in the modeled data, which can be a significant problem when the training data are limited. We derive elegant inference algorithms for our model under the mean-field paradigm and exhibit its effectiveness using the publicly available benchmark data sets.
Modeling and experimental characterization of electromigration in interconnect trees
NASA Astrophysics Data System (ADS)
Thompson, C. V.; Hau-Riege, S. P.; Andleigh, V. K.
1999-11-01
Most modeling and experimental characterization of interconnect reliability is focussed on simple straight lines terminating at pads or vias. However, laid-out integrated circuits often have interconnects with junctions and wide-to-narrow transitions. In carrying out circuit-level reliability assessments it is important to be able to assess the reliability of these more complex shapes, generally referred to as `trees.' An interconnect tree consists of continuously connected high-conductivity metal within one layer of metallization. Trees terminate at diffusion barriers at vias and contacts, and, in the general case, can have more than one terminating branch when they include junctions. We have extended the understanding of `immortality' demonstrated and analyzed for straight stud-to-stud lines, to trees of arbitrary complexity. This leads to a hierarchical approach for identifying immortal trees for specific circuit layouts and models for operation. To complete a circuit-level-reliability analysis, it is also necessary to estimate the lifetimes of the mortal trees. We have developed simulation tools that allow modeling of stress evolution and failure in arbitrarily complex trees. We are testing our models and simulations through comparisons with experiments on simple trees, such as lines broken into two segments with different currents in each segment. Models, simulations and early experimental results on the reliability of interconnect trees are shown to be consistent.
Improved frequency/voltage converters for fast quartz crystal microbalance applications.
Torres, R; García, J V; Arnau, A; Perrot, H; Kim, L To Thi; Gabrielli, C
2008-04-01
The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1 kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10 mVHz, for a frequency shift resolution of 0.1 Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5 to 10 MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.
Improved frequency/voltage converters for fast quartz crystal microbalance applications
NASA Astrophysics Data System (ADS)
Torres, R.; García, J. V.; Arnau, A.; Perrot, H.; Kim, L. To Thi; Gabrielli, C.
2008-04-01
The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10mV/Hz, for a frequency shift resolution of 0.1Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5to10MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.
Laboratory for energy smart systems (LESS).
DOT National Transportation Integrated Search
2016-12-01
The US power grid ageing fast and the societal and environmental pressures for clean energy are increasing more than ever. The ageing power infrastructure poses major limitations on energy reliability and resiliency, especially in lieu of recent extr...
A Valid and Reliable Instrument for Cognitive Complexity Rating Assignment of Chemistry Exam Items
ERIC Educational Resources Information Center
Knaus, Karen; Murphy, Kristen; Blecking, Anja; Holme, Thomas
2011-01-01
The design and use of a valid and reliable instrument for the assignment of cognitive complexity ratings to chemistry exam items is described in this paper. Use of such an instrument provides a simple method to quantify the cognitive demands of chemistry exam items. Instrument validity was established in two different ways: statistically…
ERIC Educational Resources Information Center
Wiecha, John M.; And Others
1994-01-01
Vietnamese high school students completed a food frequency questionnaire (FFQ) and completed daily diet reports for seven weeks. Data from the FFQ were compared to the food reports. The results indicated a few simple FFQ items, particularly for indicator foods such as rice, were reliable for dietary assessment for that population. (SM)
Monitoring the Wobbe Index of Natural Gas Using Fiber-Enhanced Raman Spectroscopy.
Sandfort, Vincenz; Trabold, Barbara M; Abdolvand, Amir; Bolwien, Carsten; Russell, Philip St. J; Wöllenstein, Jürgen; Palzer, Stefan
2017-11-24
The fast and reliable analysis of the natural gas composition requires the simultaneous quantification of numerous gaseous components. To this end, fiber-enhanced Raman spectroscopy is a powerful tool to detect most components in a single measurement using a single laser source. However, practical issues such as detection limit, gas exchange time and background Raman signals from the fiber material still pose obstacles to utilizing the scheme in real-world settings. This paper compares the performance of two types of hollow-core photonic crystal fiber (PCF), namely photonic bandgap PCF and kagomé-style PCF, and assesses their potential for online determination of the Wobbe index. In contrast to bandgap PCF, kagomé-PCF allows for reliable detection of Raman-scattered photons even below 1200 cm -1 , which in turn enables fast and comprehensive assessment of the natural gas quality of arbitrary mixtures.
Monitoring the Wobbe Index of Natural Gas Using Fiber-Enhanced Raman Spectroscopy
Sandfort, Vincenz; Trabold, Barbara M.; Abdolvand, Amir; Bolwien, Carsten; Russell, Philip St. J.; Wöllenstein, Jürgen
2017-01-01
The fast and reliable analysis of the natural gas composition requires the simultaneous quantification of numerous gaseous components. To this end, fiber-enhanced Raman spectroscopy is a powerful tool to detect most components in a single measurement using a single laser source. However, practical issues such as detection limit, gas exchange time and background Raman signals from the fiber material still pose obstacles to utilizing the scheme in real-world settings. This paper compares the performance of two types of hollow-core photonic crystal fiber (PCF), namely photonic bandgap PCF and kagomé-style PCF, and assesses their potential for online determination of the Wobbe index. In contrast to bandgap PCF, kagomé-PCF allows for reliable detection of Raman-scattered photons even below 1200 cm−1, which in turn enables fast and comprehensive assessment of the natural gas quality of arbitrary mixtures. PMID:29186768
Heidbrink, William W.; Ferron, John R.; Holcomb, Christopher T.; ...
2014-08-21
Here, analysis of neutron and fast-ion D α data from the DIII-D tokamak shows that Alfvén eigenmode activity degrades fast-ion confinement in many high β N, high q min, steady-state scenario discharges. (β N is the normalized plasma pressure and q min is the minimum value of the plasma safety factor.) Fast-ion diagnostics that are sensitive to the co-passing population exhibit the largest reduction relative to classical predictions. The increased fast-ion transport in discharges with strong AE activity accounts for the previously observed reduction in global confinement with increasing q min; however, not all high q min discharges show appreciablemore » degradation. Two relatively simple empirical quantities provide convenient monitors of these effects: (1) an 'AE amplitude' signal based on interferometer measurements and (2) the ratio of the neutron rate to a zero-dimensional classical prediction.« less
Computational electromagnetics: the physics of smooth versus oscillatory fields.
Chew, W C
2004-03-15
This paper starts by discussing the difference in the physics between solutions to Laplace's equation (static) and Maxwell's equations for dynamic problems (Helmholtz equation). Their differing physical characters are illustrated by how the two fields convey information away from their source point. The paper elucidates the fact that their differing physical characters affect the use of Laplacian field and Helmholtz field in imaging. They also affect the design of fast computational algorithms for electromagnetic scattering problems. Specifically, a comparison is made between fast algorithms developed using wavelets, the simple fast multipole method, and the multi-level fast multipole algorithm for electrodynamics. The impact of the physical characters of the dynamic field on the parallelization of the multi-level fast multipole algorithm is also discussed. The relationship of diagonalization of translators to group theory is presented. Finally, future areas of research for computational electromagnetics are described.
NASA Technical Reports Server (NTRS)
Gyekenyesi, John P.; Nemeth, Noel N.
1987-01-01
The SCARE (Structural Ceramics Analysis and Reliability Evaluation) computer program on statistical fast fracture reliability analysis with quadratic elements for volume distributed imperfections is enhanced to include the use of linear finite elements and the capability of designing against concurrent surface flaw induced ceramic component failure. The SCARE code is presently coupled as a postprocessor to the MSC/NASTRAN general purpose, finite element analysis program. The improved version now includes the Weibull and Batdorf statistical failure theories for both surface and volume flaw based reliability analysis. The program uses the two-parameter Weibull fracture strength cumulative failure probability distribution model with the principle of independent action for poly-axial stress states, and Batdorf's shear-sensitive as well as shear-insensitive statistical theories. The shear-sensitive surface crack configurations include the Griffith crack and Griffith notch geometries, using the total critical coplanar strain energy release rate criterion to predict mixed-mode fracture. Weibull material parameters based on both surface and volume flaw induced fracture can also be calculated from modulus of rupture bar tests, using the least squares method with known specimen geometry and grouped fracture data. The statistical fast fracture theories for surface flaw induced failure, along with selected input and output formats and options, are summarized. An example problem to demonstrate various features of the program is included.
Dec, Marta; Puchalski, Andrzej; Urban-Chmiel, Renata; Wernicki, Andrzej
2016-06-13
The objective of our study is to evaluate the potential use of Amplified 16S Ribosomal DNA Restriction Analysis (16S-ARDRA) and MALDI-TOF mass spectrometry (MS) as methods for species identification of Lactobacillus strains in poultry. A total of 80 Lactobacillus strains isolated from the cloaca of chicken, geese and turkeys were identified to the species level by MALDI-TOF MS (on-plate extraction method) and 16S-ARDRA. The two techniques produced comparable classification results, some of which were additionally confirmed by sequencing of 16S rDNA. MALDI-TOF MS enabled rapid species identification but produced more than one reliable identification result for 16.25 % of examined strains (mainly of the species L. johnsonii). For 30 % of isolates intermediate log(scores) of 1.70-1.99 were obtained, indicating correct genus identification but only presumptive species identification. The 16S-ARDRA protocol was based on digestion of 16S rDNA with the restriction enzymes MseI, HinfI, MboI and AluI. This technique was able to distinguish 17 of the 19 Lactobacillus reference species tested and enabled identification of all 80 wild isolates. L. salivarius dominated among the 15 recognized species, followed by L. johnsonii and L. ingluviei. The MALDI-TOF MS and 16S-ARDRA assays are valuable tools for the identification of avian lactobacilli to the species level. MALDI-TOF MS is a fast, simple and cost-effective technique, and despite generating a high percentage of results with a log(score) <2.00, the on-plate extraction method is characterized by high-performance. For samples for which Biotyper produces more than one reliable result, MALDI-TOF MS must be used in combination with genotypic techniques to achieve unambiguous results. 16S-ARDRA is simple, repetitive method with high power of discrimination, whose sole limitation is its inability to discriminate between species with very high 16S rDNA sequence homology, such as L. casei and L. zeae. The assays can be used for discrimination of Lactobacillus bacteria from different habitats.
NASA Astrophysics Data System (ADS)
Nair, Nirmal-Kumar
As open access market principles are applied to power systems, significant changes are happening in their planning, operation and control. In the emerging marketplace, systems are operating under higher loading conditions as markets focus greater attention to operating costs than stability and security margins. Since operating stability is a basic requirement for any power system, there is need for newer tools to ensure stability and security margins being strictly enforced in the competitive marketplace. This dissertation investigates issues associated with incorporating voltage security into the unbundled operating environment of electricity markets. It includes addressing voltage security in the monitoring, operational and planning horizons of restructured power system. This dissertation presents a new decomposition procedure to estimate voltage security usage by transactions. The procedure follows physical law and uses an index that can be monitored knowing the state of the system. The expression derived is based on composite market coordination models that have both PoolCo and OpCo transactions, in a shared stressed transmission grid. Our procedure is able to equitably distinguish the impacts of individual transactions on voltage stability, at load buses, in a simple and fast manner. This dissertation formulates a new voltage stability constrained optimal power flow (VSCOPF) using a simple voltage security index. In modern planning, composite power system reliability analysis that encompasses both adequacy and security issues is being developed. We have illustrated the applicability of our VSCOPF into composite reliability analysis. This dissertation also delves into the various applications of voltage security index. Increasingly, FACT devices are being used in restructured markets to mitigate a variety of operational problems. Their control effects on voltage security would be demonstrated using our VSCOPF procedure. Further, this dissertation investigates the application of steady state voltage stability index to detect potential dynamic voltage collapse. Finally, this dissertation examines developments in representation, standardization, communication and exchange of power system data. Power system data is the key input to all analytical engines for system operation, monitoring and control. Data exchange and dissemination could impact voltage security evaluation and therefore needs to be critically examined.
Energy Security: The Pathway to a Cost-Effective, Efficient, and Reliable Energy Future
2010-03-12
mention of these facilities is likely to incite talk of grisly death and destruction of biblical proportion. Such is the plight of the nuclear...gulf-of-mexico/,. (accessed January 12, 2010)0 31 John W Schoen, "Can Technology Help find Oil Fast Enough?", msnbc.com, December 20, 2004, http:l...John W. "Can Technology Help find Oil Fast Enough?", msnbc.com, December 20, 2004, http://www.msnbc.msn.com/id/6072980/, (accessed January 11, 2010
Phase-unwrapping algorithm by a rounding-least-squares approach
NASA Astrophysics Data System (ADS)
Juarez-Salazar, Rigoberto; Robledo-Sanchez, Carlos; Guerrero-Sanchez, Fermin
2014-02-01
A simple and efficient phase-unwrapping algorithm based on a rounding procedure and a global least-squares minimization is proposed. Instead of processing the gradient of the wrapped phase, this algorithm operates over the gradient of the phase jumps by a robust and noniterative scheme. Thus, the residue-spreading and over-smoothing effects are reduced. The algorithm's performance is compared with four well-known phase-unwrapping methods: minimum cost network flow (MCNF), fast Fourier transform (FFT), quality-guided, and branch-cut. A computer simulation and experimental results show that the proposed algorithm reaches a high-accuracy level than the MCNF method by a low-computing time similar to the FFT phase-unwrapping method. Moreover, since the proposed algorithm is simple, fast, and user-free, it could be used in metrological interferometric and fringe-projection automatic real-time applications.
Niu, Ji-Cheng; Zhou, Ting; Niu, Li-Li; Xie, Zhen-Sheng; Fang, Fang; Yang, Fu-Quan; Wu, Zhi-Yong
2018-02-01
In this work, fast isoelectric focusing (IEF) was successfully implemented on an open paper fluidic channel for simultaneous concentration and separation of proteins from complex matrix. With this simple device, IEF can be finished in 10 min with a resolution of 0.03 pH units and concentration factor of 10, as estimated by color model proteins by smartphone-based colorimetric detection. Fast detection of albumin from human serum and glycated hemoglobin (HBA1c) from blood cell was demonstrated. In addition, off-line identification of the model proteins from the IEF fractions with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was also shown. This PAD IEF is potentially useful either for point of care test (POCT) or biomarker analysis as a cost-effective sample pretreatment method.
NASA Astrophysics Data System (ADS)
Chen, LeuJen; Kim, Seong Heon; Lee, Alfred K. H.; de Lozanne, Alex
2012-01-01
We describe a new type of circuit designed for driving piezoelectric positioners that rely on the stick-slip phenomenon. The circuit can be used for inertial positioners that have only one piezoelectric element (or multiple elements that are moved simultaneously) or for designs using a sequential movement of independent piezoelectric elements. A relay switches the piezoelectric elements between a high voltage source and ground, thus creating a fast voltage step followed by a slow ramp produced by the exponential discharging of the piezoelectric elements through a series resistor. A timing cascade is generated by having each relay power the next relay in the sequence. This design is simple and inexpensive. While it was developed for scanning probe microscopes, it may be useful for any piezoelectric motor based on a fast jump followed by a slow relaxation.
The Tacrolimus Metabolism Rate Influences Renal Function after Kidney Transplantation
Thölking, Gerold; Fortmann, Christian; Koch, Raphael; Gerth, Hans Ulrich; Pabst, Dirk; Pavenstädt, Hermann; Kabar, Iyad; Hüsing, Anna; Wolters, Heiner
2014-01-01
The effective calcineurin inhibitor (CNI) tacrolimus (Tac) is an integral part of the standard immunosuppressive regimen after renal transplantation (RTx). However, as a potent CNI it has nephrotoxic potential leading to impaired renal function in some cases. Therefore, it is of high clinical impact to identify factors which can predict who is endangered to develop CNI toxicity. We hypothesized that the Tac metabolism rate expressed as the blood concentration normalized by the dose (C/D ratio) is such a simple predictor. Therefore, we analyzed the impact of the C/D ratio on kidney function after RTx. Renal function was analyzed 1, 2, 3, 6, 12 and 24 months after RTx in 248 patients with an immunosuppressive regimen including basiliximab, tacrolimus, mycophenolate mofetil and prednisolone. According to keep the approach simple, patients were split into three C/D groups: fast, intermediate and slow metabolizers. Notably, compared with slow metabolizers fast metabolizers of Tac showed significantly lower estimated glomerular filtration rate (eGFR) values at all the time points analyzed. Moreover, fast metabolizers underwent more indication renal biopsies (p = 0.006) which revealed a higher incidence of CNI nephrotoxicity (p = 0.015) and BK nephropathy (p = 0.024) in this group. We herein identified the C/D ratio as an easy calculable risk factor for the development of CNI nephrotoxicity and BK nephropathy after RTx. We propose that the simple C/D ratio should be taken into account early in patient’s risk management strategies. PMID:25340655
Vlach, Jiří; Junková, Petra; Karamonová, Ludmila; Blažková, Martina; Fukal, Ladislav
2017-01-01
ABSTRACT In the last decade, strains of the genera Franconibacter and Siccibacter have been misclassified as first Enterobacter and later Cronobacter. Because Cronobacter is a serious foodborne pathogen that affects premature neonates and elderly individuals, such misidentification may not only falsify epidemiological statistics but also lead to tests of powdered infant formula or other foods giving false results. Currently, the main ways of identifying Franconibacter and Siccibacter strains are by biochemical testing or by sequencing of the fusA gene as part of Cronobacter multilocus sequence typing (MLST), but in relation to these strains the former is generally highly difficult and unreliable while the latter remains expensive. To address this, we developed a fast, simple, and most importantly, reliable method for Franconibacter and Siccibacter identification based on intact-cell matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS). Our method integrates the following steps: data preprocessing using mMass software; principal-component analysis (PCA) for the selection of mass spectrum fingerprints of Franconibacter and Siccibacter strains; optimization of the Biotyper database settings for the creation of main spectrum projections (MSPs). This methodology enabled us to create an in-house MALDI MS database that extends the current MALDI Biotyper database by including Franconibacter and Siccibacter strains. Finally, we verified our approach using seven previously unclassified strains, all of which were correctly identified, thereby validating our method. IMPORTANCE We show that the majority of methods currently used for the identification of Franconibacter and Siccibacter bacteria are not able to properly distinguish these strains from those of Cronobacter. While sequencing of the fusA gene as part of Cronobacter MLST remains the most reliable such method, it is highly expensive and time-consuming. Here, we demonstrate a cost-effective and reliable alternative that correctly distinguishes between Franconibacter, Siccibacter, and Cronobacter bacteria and identifies Franconibacter and Siccibacter at the species level. Using intact-cell MALDI-TOF MS, we extend the current MALDI Biotyper database with 11 Franconibacter and Siccibacter MSPs. In addition, the use of our approach is likely to lead to a more reliable identification scheme for Franconibacter and Siccibacter strains and, consequently, a more trustworthy epidemiological picture of their involvement in disease. PMID:28455327
Fast realization of nonrecursive digital filters with limits on signal delay
NASA Astrophysics Data System (ADS)
Titov, M. A.; Bondarenko, N. N.
1983-07-01
Attention is given to the problem of achieving a fast realization of nonrecursive digital filters with the aim of reducing signal delay. It is shown that a realization wherein the impulse characteristic of the filter is divided into blocks satisfies the delay requirements and is almost as economical in terms of the number of multiplications as conventional fast convolution. In addition, the block method leads to a reduction in the needed size of the memory and in the number of additions; the short-convolution procedure is substantially simplified. Finally, the block method facilitates the paralleling of computations owing to the simple transfers between subfilters.
Ferreira, L; Sánchez-Juanes, F; Porras-Guerra, I; García-García, M I; García-Sánchez, J E; González-Buitrago, J M; Muñoz-Bellido, J L
2011-04-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) allows a fast and reliable bacterial identification from culture plates. Direct analysis of clinical samples may increase its usefulness in samples in which a fast identification of microorganisms can guide empirical treatment, such as blood cultures (BC). Three hundred and thirty BC, reported as positive by the automated BC incubation device, were processed by conventional methods for BC processing, and by a fast method based on direct MALDI-TOF MS. Three hundred and eighteen of them yield growth on culture plates, and 12 were false positive. The MALDI-TOF MS-based method reported that no peaks were found, or the absence of a reliable identification profile, in all these false positive BC. No mixed cultures were found. Among these 318 BC, we isolated 61 Gram-negatives (GN), 239 Gram-positives (GP) and 18 fungi. Microorganism identifications in GN were coincident with conventional identification, at the species level, in 83.3% of BC and, at the genus level, in 96.6%. In GP, identifications were coincident with conventional identification in 31.8% of BC at the species level, and in 64.8% at the genus level. Fungaemia was not reliably detected by MALDI-TOF. In 18 BC positive for Candida species (eight C. albicans, nine C. parapsilosis and one C. tropicalis), no microorganisms were identified at the species level, and only one (5.6%) was detected at the genus level. The results of the present study show that this fast, MALDI-TOF MS-based method allows bacterial identification directly from presumptively positive BC in a short time (<30 min), with a high accuracy, especially when GN bacteria are involved. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.
VET Program Completion Rates: An Evaluation of the Current Method. Occasional Paper
ERIC Educational Resources Information Center
National Centre for Vocational Education Research (NCVER), 2016
2016-01-01
This work asks one simple question: "how reliable is the method used by the National Centre for Vocational Education Research (NCVER) to estimate projected rates of VET program completion?" In other words, how well do early projections align with actual completion rates some years later? Completion rates are simple to calculate with a…
Development of a Three-Tier Test to Assess Misconceptions about Simple Electric Circuits
ERIC Educational Resources Information Center
Pesman, Haki; Eryilmaz, Ali
2010-01-01
The authors aimed to propose a valid and reliable diagnostic instrument by developing a three-tier test on simple electric circuits. Based on findings from the interviews, open-ended questions, and the related literature, the test was developed and administered to 124 high school students. In addition to some qualitative techniques for…
Comparison of different objective functions for parameterization of simple respiration models
M.T. van Wijk; B. van Putten; D.Y. Hollinger; A.D. Richardson
2008-01-01
The eddy covariance measurements of carbon dioxide fluxes collected around the world offer a rich source for detailed data analysis. Simple, aggregated models are attractive tools for gap filling, budget calculation, and upscaling in space and time. Key in the application of these models is their parameterization and a robust estimate of the uncertainty and reliability...
An Operationally Simple Sonogashira Reaction for an Undergraduate Organic Chemistry Laboratory Class
ERIC Educational Resources Information Center
Cranwell, Philippa B.; Peterson, Alexander M.; Littlefield, Benjamin T. R.; Russell, Andrew T.
2015-01-01
An operationally simple, reliable, and cheap Sonogashira reaction suitable for an undergraduate laboratory class that can be completed within a day-long (8 h) laboratory session has been developed. Cross-coupling is carried out between 2-methyl-3-butyn-2-ol and various aryl iodides using catalytic amounts of bis(triphenylphosphine)palladium(II)…
Reliability of segmental accelerations measured using a new wireless gait analysis system.
Kavanagh, Justin J; Morrison, Steven; James, Daniel A; Barrett, Rod
2006-01-01
The purpose of this study was to determine the inter- and intra-examiner reliability, and stride-to-stride reliability, of an accelerometer-based gait analysis system which measured 3D accelerations of the upper and lower body during self-selected slow, preferred and fast walking speeds. Eight subjects attended two testing sessions in which accelerometers were attached to the head, neck, lower trunk, and right shank. In the initial testing session, two different examiners attached the accelerometers and performed the same testing procedures. A single examiner repeated the procedure in a subsequent testing session. All data were collected using a new wireless gait analysis system, which features near real-time data transmission via a Bluetooth network. Reliability for each testing condition (4 locations, 3 directions, 3 speeds) was quantified using a waveform similarity statistic known as the coefficient of multiple determination (CMD). CMD's ranged from 0.60 to 0.98 across all test conditions and were not significantly different for inter-examiner (0.86), intra-examiner (0.87), and stride-to-stride reliability (0.86). The highest repeatability for the effect of location, direction and walking speed were for the shank segment (0.94), the vertical direction (0.91) and the fast walking speed (0.91), respectively. Overall, these results indicate that a high degree of waveform repeatability was obtained using a new gait system under test-retest conditions involving single and dual examiners. Furthermore, differences in acceleration waveform repeatability associated with the reapplication of accelerometers were small in relation to normal motor variability.
A reliable transmission protocol for ZigBee-based wireless patient monitoring.
Chen, Shyr-Kuen; Kao, Tsair; Chan, Chia-Tai; Huang, Chih-Ning; Chiang, Chih-Yen; Lai, Chin-Yu; Tung, Tse-Hua; Wang, Pi-Chung
2012-01-01
Patient monitoring systems are gaining their importance as the fast-growing global elderly population increases demands for caretaking. These systems use wireless technologies to transmit vital signs for medical evaluation. In a multihop ZigBee network, the existing systems usually use broadcast or multicast schemes to increase the reliability of signals transmission; however, both the schemes lead to significantly higher network traffic and end-to-end transmission delay. In this paper, we present a reliable transmission protocol based on anycast routing for wireless patient monitoring. Our scheme automatically selects the closest data receiver in an anycast group as a destination to reduce the transmission latency as well as the control overhead. The new protocol also shortens the latency of path recovery by initiating route recovery from the intermediate routers of the original path. On the basis of a reliable transmission scheme, we implement a ZigBee device for fall monitoring, which integrates fall detection, indoor positioning, and ECG monitoring. When the triaxial accelerometer of the device detects a fall, the current position of the patient is transmitted to an emergency center through a ZigBee network. In order to clarify the situation of the fallen patient, 4-s ECG signals are also transmitted. Our transmission scheme ensures the successful transmission of these critical messages. The experimental results show that our scheme is fast and reliable. We also demonstrate that our devices can seamlessly integrate with the next generation technology of wireless wide area network, worldwide interoperability for microwave access, to achieve real-time patient monitoring.
Intelligent Mobile Autonomous System (IMAS).
1987-01-01
the "tile" of tesselation at a level (grain, discrete, pixel, or voxel of the space). These terms can be used intermittently , and each of them...search on the original level of traversability space is not fast enough to be considered for actual control application. Alternatives to limit the...0 (b) It must be concise and easy to "compute". In other words there must exist simple, fast procedures for instantiating the "words" or "sentences
Delineating parameter unidentifiabilities in complex models
NASA Astrophysics Data System (ADS)
Raman, Dhruva V.; Anderson, James; Papachristodoulou, Antonis
2017-03-01
Scientists use mathematical modeling as a tool for understanding and predicting the properties of complex physical systems. In highly parametrized models there often exist relationships between parameters over which model predictions are identical, or nearly identical. These are known as structural or practical unidentifiabilities, respectively. They are hard to diagnose and make reliable parameter estimation from data impossible. They furthermore imply the existence of an underlying model simplification. We describe a scalable method for detecting unidentifiabilities, as well as the functional relations defining them, for generic models. This allows for model simplification, and appreciation of which parameters (or functions thereof) cannot be estimated from data. Our algorithm can identify features such as redundant mechanisms and fast time-scale subsystems, as well as the regimes in parameter space over which such approximations are valid. We base our algorithm on a quantification of regional parametric sensitivity that we call `multiscale sloppiness'. Traditionally, the link between parametric sensitivity and the conditioning of the parameter estimation problem is made locally, through the Fisher information matrix. This is valid in the regime of infinitesimal measurement uncertainty. We demonstrate the duality between multiscale sloppiness and the geometry of confidence regions surrounding parameter estimates made where measurement uncertainty is non-negligible. Further theoretical relationships are provided linking multiscale sloppiness to the likelihood-ratio test. From this, we show that a local sensitivity analysis (as typically done) is insufficient for determining the reliability of parameter estimation, even with simple (non)linear systems. Our algorithm can provide a tractable alternative. We finally apply our methods to a large-scale, benchmark systems biology model of necrosis factor (NF)-κ B , uncovering unidentifiabilities.
Template Synthesis of Nanostructured Polymeric Membranes by Inkjet Printing.
Gao, Peng; Hunter, Aaron; Benavides, Sherwood; Summe, Mark J; Gao, Feng; Phillip, William A
2016-02-10
The fabrication of functional nanomaterials with complex structures has been serving great scientific and practical interests, but current fabrication and patterning methods are generally costly and laborious. Here, we introduce a versatile, reliable, and rapid method for fabricating nanostructured polymeric materials. The novel method is based on a combination of inkjet printing and template synthesis, and its utility and advantages in the fabrication of polymeric nanomaterials is demonstrated through three examples: the generation of polymeric nanotubes, nanowires, and thin films. Layer-by-layer-assembled nanotubes can be synthesized in a polycarbonate track-etched (PCTE) membrane by printing poly(allylamine hydrochloride) and poly(styrenesulfonate) sequentially. This sequential deposition of polyelectrolyte ink enables control over the surface charge within the nanotubes. By a simple change of the printing conditions, polymeric nanotubes or nanowires were prepared by printing poly(vinyl alcohol) in a PCTE template. In this case, the high-throughput nature of the method enables functional nanomaterials to be generated in under 3 min. Furthermore, we demonstrate that inkjet printing paired with template synthesis can be used to generate patterns comprised of chemically distinct nanomaterials. Thin polymeric films of layer-by-layer-assembled poly(allylamine hydrochloride) and poly(styrenesulfonate) are printed on a PCTE membrane. Track-etched membranes covered with the deposited thin films reject ions and can potentially be utilized as nanofiltration membranes. When the fabrication of these different classes of nanostructured materials is demonstrated, the advantages of pairing template synthesis with inkjet printing, which include fast and reliable deposition, judicious use of the deposited materials, and the ability to design chemically patterned surfaces, are highlighted.
PREOXYGENATION: COULD SAFETY MEASURE BE MADE LESS DANGEROUS?.
Kamenskaya, L U; Lebedinskiy, K M
2016-11-01
While providing reserve time for dificult airway management, preoxygenation with pure oxygen increases the risk of pulmonary complications due to absorption atelectases. The authors explored when it could be appropriate to prevent atelectases by preoxygenation with decreased FiO₂. ASA I-II elective gynecological surgery patients were randomized among five groups (n = 22 each) with preoxygenation using FiO₂ 100, 70, 60, 60% + PEEP 5 mbar and 50%. Even FiO₂ 70% led to decrease. in safe apnea time (i.e. time interval to Sp²O₂ 95%) by two, while FiO₂ 50% - by more than three times. Furthermore, in five similar additional groups of women with same techniques ofpreoxygenation (n = 10 each) it was shown that for FiO₂ 5 70% very fast pattern of SpO2 fall after the first change ofpulseoxymeter figure (100% by 99%) is typical: interval to SpO2 90% was less than 1 min, while for FiO₂ 100% it lasts for 200 s. Since critical problem is "Cannot intubate, cannot ventilate", the authors tried to focus on the difficultfacemask ventilation prognosis. In the group of 71 elective general surgery patients (31 males, 40 females, ASA I-III) original prognostic model based on seven simple bedside tests (removable dentures, beard, snoring, Mallampati class 2-4, age > 50 y.o., BM > 30 kg/m², sternomental distance < 12 cm) demonstrated the reliability of difficult facemask ventilation negative prognosis of 97,5%. The authors suggest that only in patients with reliable prognosis of easy facemask ventilation prevention ofpulmonary complications by preoxygenation with FiO₂ 50-60% could be safely recommended.
Shelley, Jacob T; Hieftje, Gary M
2010-04-01
The recent development of ambient desorption/ionization mass spectrometry (ADI-MS) has enabled fast, simple analysis of many different sample types. The ADI-MS sources have numerous advantages, including little or no required sample pre-treatment, simple mass spectra, and direct analysis of solids and liquids. However, problems of competitive ionization and limited fragmentation require sample-constituent separation, high mass accuracy, and/or tandem mass spectrometry (MS/MS) to detect, identify, and quantify unknown analytes. To maintain the inherent high throughput of ADI-MS, it is essential for the ion source/mass analyzer combination to measure fast transient signals and provide structural information. In the current study, the flowing atmospheric-pressure afterglow (FAPA) ionization source is coupled with a time-of-flight mass spectrometer (TOF-MS) to analyze fast transient signals (<500 ms FWHM). It was found that gas chromatography (GC) coupled with the FAPA source resulted in a reproducible (<5% RSD) and sensitive (detection limits of <6 fmol for a mixture of herbicides) system with analysis times of ca. 5 min. Introducing analytes to the FAPA in a transient was also shown to significantly reduce matrix effects caused by competitive ionization by minimizing the number and amount of constituents introduced into the ionization source. Additionally, MS/MS with FAPA-TOF-MS, enabling analyte identification, was performed via first-stage collision-induced dissociation (CID). Lastly, molecular and structural information was obtained across a fast transient peak by modulating the conditions that caused the first-stage CID.
Time Evolving Fission Chain Theory and Fast Neutron and Gamma-Ray Counting Distributions
Kim, K. S.; Nakae, L. F.; Prasad, M. K.; ...
2015-11-01
Here, we solve a simple theoretical model of time evolving fission chains due to Feynman that generalizes and asymptotically approaches the point model theory. The point model theory has been used to analyze thermal neutron counting data. This extension of the theory underlies fast counting data for both neutrons and gamma rays from metal systems. Fast neutron and gamma-ray counting is now possible using liquid scintillator arrays with nanosecond time resolution. For individual fission chains, the differential equations describing three correlated probability distributions are solved: the time-dependent internal neutron population, accumulation of fissions in time, and accumulation of leaked neutronsmore » in time. Explicit analytic formulas are given for correlated moments of the time evolving chain populations. The equations for random time gate fast neutron and gamma-ray counting distributions, due to randomly initiated chains, are presented. Correlated moment equations are given for both random time gate and triggered time gate counting. There are explicit formulas for all correlated moments are given up to triple order, for all combinations of correlated fast neutrons and gamma rays. The nonlinear differential equations for probabilities for time dependent fission chain populations have a remarkably simple Monte Carlo realization. A Monte Carlo code was developed for this theory and is shown to statistically realize the solutions to the fission chain theory probability distributions. Combined with random initiation of chains and detection of external quanta, the Monte Carlo code generates time tagged data for neutron and gamma-ray counting and from these data the counting distributions.« less
Performance Evaluation of FAST TCP Traffic-Flows in Multihomed MANETs
NASA Astrophysics Data System (ADS)
Mudassir, Mumajjed Ul; Akram, Adeel
In Mobile Ad hoc Networks (MANETs) an efficient communication protocol is required at the transport layer. Mobile nodes moving around will have temporary and rather short-lived connectivity with each other and the Internet, thus requiring efficient utilization of network resources. Moreover the problems arising due to high mobility, collision and congestion must also be considered. Multihoming allows higher reliability and enhancement of network throughput. FAST TCP is a new promising transport layer protocol developed for high-speed high-latency networks. In this paper, we have analyzed the performance of FAST TCP traffic flows in multihomed MANETs and compared it with standard TCP (TCP Reno) traffic flows in non-multihomed MANETs.
A digitally implemented preambleless demodulator for maritime and mobile data communications
NASA Astrophysics Data System (ADS)
Chalmers, Harvey; Shenoy, Ajit; Verahrami, Farhad B.
The hardware design and software algorithms for a low-bit-rate, low-cost, all-digital preambleless demodulator are described. The demodulator operates under severe high-noise conditions, fast Doppler frequency shifts, large frequency offsets, and multipath fading. Sophisticated algorithms, including a fast Fourier transform (FFT)-based burst acquisition algorithm, a cycle-slip resistant carrier phase tracker, an innovative Doppler tracker, and a fast acquisition symbol synchronizer, were developed and extensively simulated for reliable burst reception. The compact digital signal processor (DSP)-based demodulator hardware uses a unique personal computer test interface for downloading test data files. The demodulator test results demonstrate a near-ideal performance within 0.2 dB of theory.
Nelson, Melissa C; Lytle, Leslie A
2009-04-01
Sweetened beverage and fast-food intake have been identified as important targets for obesity prevention. However, there are few brief dietary assessment tools available to evaluate these behaviors among adolescents. The objective of this research was to examine reliability and validity of a 22-item dietary screener assessing adolescent consumption of specific energy-containing and non-energy-containing beverages (nine items) and fast food (13 items). The screener was administered to adolescents (ages 11 to 18 years) recruited from the Minneapolis/St Paul, MN, metro region. One sample of adolescents completed test-retest reliability of the screener (n=33, primarily white adolescents). Another adolescent sample completed the screener along with three 24-hour dietary recalls to assess criterion validity (n=59 white adolescents). Test-retest assessments were completed approximately 7 to 14 days apart, and agreement between the two administrations of the screener was substantial, with most items yielding Spearman correlations and kappa statistics that were >0.60. When compared to the gold standard dietary recall data, findings indicate that the validity of the screener items assessing adolescents' intake of regular soda, sports drinks, milk, and water was fair. However, the differential assessment periods captured by the two methods (ie, 1 month for the screener vs 3 days for the recalls) posed challenges in analysis and made it impossible to assess the validity of some screener items. Overall while these screener items largely represent reliable measures with fair validity, our findings highlight the challenges inherent in the validation of brief dietary assessment tools.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Hyejin; Jeong, Sinyoung; Ko, Eunbyeol
2015-05-15
Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, wemore » analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.« less
Looking a gift horse in the mouth: Evaluation of wide-field asteroid photometric surveys
NASA Astrophysics Data System (ADS)
Harris, Alan W.; Pravec, Petr; Warner, Brian D.
2012-09-01
It has recently become possible to do a photometric survey of many asteroids at once, rather than observing single asteroids one (or occasionally a couple) at a time. We evaluate two such surveys. Dermawan et al. (Dermawan et al. [2011]. Publ. Astron. Soc. Jpn. 63, S555-S576) observed one night on the Subaru 8.2 m telescope, and Masiero et al. (Masiero, J., Jedicke, R., Durech, J., Gwen, S., Denneau, L., Larsen, J. [2009]. Icarus 204, 145-171) observed six nights over 2 weeks with the 3.6 m CFHT. Dermawan claimed 83 rotation periods from 127 detected asteroids; Masiero et al. claimed 218 rotation periods from 828 detections. Both teams claim a number of super-fast rotators (P < 2.2 h) among main belt asteroids larger than 250 m diameter, some up to several km in diameter. This would imply that the spin rate distribution of main belt asteroids differs from like-sized NEAs, that there are larger super-fast rotators (monolithic asteroids) in the main belt than among NEAs. Here we evaluate these survey results, applying the same criteria for reliability of results that we apply to all results listed in our Lightcurve Database (Warner, B.D., Harris, A.W., Pravec, P. [2009a]. Icarus 202, 134-146). In doing so, we assigned reliability estimates judged sufficient for inclusion in statistical studies for only 27 out of 83 (33%) periods claimed by Dermawan, and only 87 out of 218 (40%) periods reported by Masiero et al.; none of the super-fast rotators larger than about 250 m diameter claimed by either survey received a reliability rating judged sufficient for analysis. We find no reliable basis for the claim of different rotation properties between main belt and near-Earth asteroids. Our analysis presents a cautionary message for future surveys.
Hecimovich, Mark; King, Doug; Dempsey, Alasdair R; Murphy, Myles
2018-03-28
Sport-related concussion (SRC) research has focused on impaired oculomotor function. The King-Devick (K-D) test measures oculomotor performance and is reported to identify suboptimal brain function. The use of the K-D test in Australian football (AF), a sport involving body contact and tackling, has not been documented. Therefore, the objective of this study was to determine the test-retest reliability and diagnostic accuracy of the K-D test on a sub-elite AF team. Prospective cohort study METHODS: In total, 22 male players (19.6+2.3 years) were tested and re-tested on the K-D test. Those suspected of having a SRC secondary to a significant head impact were tested. Randomly selected additional players without SRC were assessed for comparison. There were observable learning effects between the first and second baseline testing (48 vs. 46s). The ICC for the first and second baseline tests was 0.91. Post-match test times were longer than the baseline times for players with SRC (n=7) (-1.9s; z=-5.08; p<0.0001). Players tested with no signs of SRC (n=13) had an improvement in time when compared with their baseline score (3.0s; z=-4.38; p<0.0001). The overall sensitivity was 0.98, specificity 0.96, and a kappa of κ=0.94. The positive likelihood ratio was 11.6 and the positive predictive value was 89.0%. This study supports the use of the K-D test due to its test-retest reliability, high sensitivity and specificity, and fast and simple use that is ideal for sports medicine professionals to make quick judgement on management and playability. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Bavuso, Salvatore J.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. The Hybrid Automated Reliability Predictor (HARP) tutorial provides insight into HARP modeling techniques and the interactive textual prompting input language via a step-by-step explanation and demonstration of HARP's fault occurrence/repair model and the fault/error handling models. Example applications are worked in their entirety and the HARP tabular output data are presented for each. Simple models are presented at first with each succeeding example demonstrating greater modeling power and complexity. This document is not intended to present the theoretical and mathematical basis for HARP.
HI Intensity Mapping with FAST
NASA Astrophysics Data System (ADS)
Bigot-Sazy, M.-A.; Ma, Y.-Z.; Battye, R. A.; Browne, I. W. A.; Chen, T.; Dickinson, C.; Harper, S.; Maffei, B.; Olivari, L. C.; Wilkinsondagger, P. N.
2016-02-01
We discuss the detectability of large-scale HI intensity fluctuations using the FAST telescope. We present forecasts for the accuracy of measuring the Baryonic Acoustic Oscillations and constraining the properties of dark energy. The FAST 19-beam L-band receivers (1.05-1.45 GHz) can provide constraints on the matter power spectrum and dark energy equation of state parameters (w0,wa) that are comparable to the BINGO and CHIME experiments. For one year of integration time we find that the optimal survey area is 6000 deg2. However, observing with larger frequency coverage at higher redshift (0.95-1.35 GHz) improves the projected errorbars on the HI power spectrum by more than 2 σ confidence level. The combined constraints from FAST, CHIME, BINGO and Planck CMB observations can provide reliable, stringent constraints on the dark energy equation of state.
GIGA: a simple, efficient algorithm for gene tree inference in the genomic age
2010-01-01
Background Phylogenetic relationships between genes are not only of theoretical interest: they enable us to learn about human genes through the experimental work on their relatives in numerous model organisms from bacteria to fruit flies and mice. Yet the most commonly used computational algorithms for reconstructing gene trees can be inaccurate for numerous reasons, both algorithmic and biological. Additional information beyond gene sequence data has been shown to improve the accuracy of reconstructions, though at great computational cost. Results We describe a simple, fast algorithm for inferring gene phylogenies, which makes use of information that was not available prior to the genomic age: namely, a reliable species tree spanning much of the tree of life, and knowledge of the complete complement of genes in a species' genome. The algorithm, called GIGA, constructs trees agglomeratively from a distance matrix representation of sequences, using simple rules to incorporate this genomic age information. GIGA makes use of a novel conceptualization of gene trees as being composed of orthologous subtrees (containing only speciation events), which are joined by other evolutionary events such as gene duplication or horizontal gene transfer. An important innovation in GIGA is that, at every step in the agglomeration process, the tree is interpreted/reinterpreted in terms of the evolutionary events that created it. Remarkably, GIGA performs well even when using a very simple distance metric (pairwise sequence differences) and no distance averaging over clades during the tree construction process. Conclusions GIGA is efficient, allowing phylogenetic reconstruction of very large gene families and determination of orthologs on a large scale. It is exceptionally robust to adding more gene sequences, opening up the possibility of creating stable identifiers for referring to not only extant genes, but also their common ancestors. We compared trees produced by GIGA to those in the TreeFam database, and they were very similar in general, with most differences likely due to poor alignment quality. However, some remaining differences are algorithmic, and can be explained by the fact that GIGA tends to put a larger emphasis on minimizing gene duplication and deletion events. PMID:20534164
GIGA: a simple, efficient algorithm for gene tree inference in the genomic age.
Thomas, Paul D
2010-06-09
Phylogenetic relationships between genes are not only of theoretical interest: they enable us to learn about human genes through the experimental work on their relatives in numerous model organisms from bacteria to fruit flies and mice. Yet the most commonly used computational algorithms for reconstructing gene trees can be inaccurate for numerous reasons, both algorithmic and biological. Additional information beyond gene sequence data has been shown to improve the accuracy of reconstructions, though at great computational cost. We describe a simple, fast algorithm for inferring gene phylogenies, which makes use of information that was not available prior to the genomic age: namely, a reliable species tree spanning much of the tree of life, and knowledge of the complete complement of genes in a species' genome. The algorithm, called GIGA, constructs trees agglomeratively from a distance matrix representation of sequences, using simple rules to incorporate this genomic age information. GIGA makes use of a novel conceptualization of gene trees as being composed of orthologous subtrees (containing only speciation events), which are joined by other evolutionary events such as gene duplication or horizontal gene transfer. An important innovation in GIGA is that, at every step in the agglomeration process, the tree is interpreted/reinterpreted in terms of the evolutionary events that created it. Remarkably, GIGA performs well even when using a very simple distance metric (pairwise sequence differences) and no distance averaging over clades during the tree construction process. GIGA is efficient, allowing phylogenetic reconstruction of very large gene families and determination of orthologs on a large scale. It is exceptionally robust to adding more gene sequences, opening up the possibility of creating stable identifiers for referring to not only extant genes, but also their common ancestors. We compared trees produced by GIGA to those in the TreeFam database, and they were very similar in general, with most differences likely due to poor alignment quality. However, some remaining differences are algorithmic, and can be explained by the fact that GIGA tends to put a larger emphasis on minimizing gene duplication and deletion events.
Context-free parsing with connectionist networks
NASA Astrophysics Data System (ADS)
Fanty, M. A.
1986-08-01
This paper presents a simple algorithm which converts any context-free grammar into a connectionist network which parses strings (of arbitrary but fixed maximum length) in the language defined by that grammar. The network is fast, O(n), and deterministicd. It consists of binary units which compute a simple function of their input. When the grammar is put in Chomsky normal form, O(n3) units needed to parse inputs of length up to n.
Robust 1-Bit Compressive Sensing via Binary Stable Embeddings of Sparse Vectors
2011-04-15
funded by Mitsubishi Electric Research Laboratories. †ICTEAM Institute, ELEN Department, Université catholique de Louvain (UCL), B-1348 Louvain-la-Neuve...reduced to a simple comparator that tests for values above or below zero, enabling extremely simple, efficient, and fast quantization. A 1-bit quantizer is...these two terms appears to be significantly different, according to the previously discussed experiments. To test the hypothesis that this term is the key
Can Processed Foods Be Part of a Healthy Diet?
... Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering the Menu Ordering Your Meal Eating Fast ... make smart choices in the grocery store and restaurants. Choose healthier processed foods. Read food labels. This ...
NASA Astrophysics Data System (ADS)
Gallego, Sandra F.; Højlund, Kurt; Ejsing, Christer S.
2018-01-01
Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MSALL technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133-148 [1]) to support in-depth structural elucidation of lipid molecules. [Figure not available: see fulltext.
Khan, Ismail; Iqbal, Zafar; Khan, Abad; Hassan, Muhammad; Nasir, Fazle; Raza, Abida; Ahmad, Lateef; Khan, Amjad; Akhlaq Mughal, Muhammad
2016-10-15
A simple, economical, fast, and sensitive RP-HPLC-UV method has been developed for the simultaneous quantification of Sorafenib and paclitaxel in biological samples and formulations using piroxicam as an internal standard. The experimental conditions were optimized and method was validated according to the standard guidelines. The separation of both the analytes and internal standard was achieved on Discovery HS C18 column (250mm×4.6mm, 5μm) using Acetonitrile and TFA (0.025%) in the ratio of (65:35V/V) as the mobile phase in isocratic mode at a flow rate of 1ml/min, with a wavelength of 245nm and at a column oven temperature of 25°Cin a short run time of 12min. The limits of detection (LLOD) were 5 and 10ng/ml while the limits of quantification (LLOQ) were 10 and 15ng/ml for sorafenib and paclitaxel, respectively. Sorafenib, paclitaxel and piroxicam (IS) were extracted from biological samples by applying acetonitrile as a precipitating and extraction solvent. The method is linear in the range of 15-20,000ng/ml for paclitaxel and 10-5000ng/ml for sorafenib, respectively. The method is sensitive and reliable by considering both of its intra-day and inter-day co-efficient of variance. The method was successfully applied for the quantification of the above mentioned drugs in plasma. The developed method will be applied towards sorafenib and paclitaxel pharmacokinetics studies in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.
Gallego, Sandra F; Højlund, Kurt; Ejsing, Christer S
2018-01-01
Reliable, cost-effective, and gold-standard absolute quantification of non-esterified cholesterol in human plasma is of paramount importance in clinical lipidomics and for the monitoring of metabolic health. Here, we compared the performance of three mass spectrometric approaches available for direct detection and quantification of cholesterol in extracts of human plasma. These approaches are high resolution full scan Fourier transform mass spectrometry (FTMS) analysis, parallel reaction monitoring (PRM), and novel multiplexed MS/MS (MSX) technology, where fragments from selected precursor ions are detected simultaneously. Evaluating the performance of these approaches in terms of dynamic quantification range, linearity, and analytical precision showed that the MSX-based approach is superior to that of the FTMS and PRM-based approaches. To further show the efficacy of this approach, we devised a simple routine for extensive plasma lipidome characterization using only 8 μL of plasma, using a new commercially available ready-to-spike-in mixture with 14 synthetic lipid standards, and executing a single 6 min sample injection with combined MSX analysis for cholesterol quantification and FTMS analysis for quantification of sterol esters, glycerolipids, glycerophospholipids, and sphingolipids. Using this simple routine afforded reproducible and absolute quantification of 200 lipid species encompassing 13 lipid classes in human plasma samples. Notably, the analysis time of this procedure can be shortened for high throughput-oriented clinical lipidomics studies or extended with more advanced MS ALL technology (Almeida R. et al., J. Am. Soc. Mass Spectrom. 26, 133-148 [1]) to support in-depth structural elucidation of lipid molecules. Graphical Abstract ᅟ.
ERIC Educational Resources Information Center
Horn, Aaron S.; Lee, Giljae
2016-01-01
A relatively simple way of measuring institutional effectiveness in relation to degree completion is to estimate the difference between an actual and predicted graduation rate, but the reliability and validity of this method have not been thoroughly examined. Longitudinal data were obtained from IPEDS for both public and private not-for-profit…
Reliability Analysis of Uniaxially Ground Brittle Materials
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Nemeth, Noel N.; Powers, Lynn M.; Choi, Sung R.
1995-01-01
The fast fracture strength distribution of uniaxially ground, alpha silicon carbide was investigated as a function of grinding angle relative to the principal stress direction in flexure. Both as-ground and ground/annealed surfaces were investigated. The resulting flexural strength distributions were used to verify reliability models and predict the strength distribution of larger plate specimens tested in biaxial flexure. Complete fractography was done on the specimens. Failures occurred from agglomerates, machining cracks, or hybrid flaws that consisted of a machining crack located at a processing agglomerate. Annealing eliminated failures due to machining damage. Reliability analyses were performed using two and three parameter Weibull and Batdorf methodologies. The Weibull size effect was demonstrated for machining flaws. Mixed mode reliability models reasonably predicted the strength distributions of uniaxial flexure and biaxial plate specimens.
Olajide, Kike; Munjiza, Jasna; Moran, Paul; O'Connell, Lesley; Newton-Howes, Giles; Bassett, Paul; Akintomide, Gbolagade; Ng, Nicola; Tyrer, Peter; Mulder, Roger; Crawford, Mike J
2018-02-01
Personality disorder (PD) is increasingly categorized according to its severity, but there is no simple way to screen for severity according to ICD-11 criteria. We set out to develop the Standardized Assessment of Severity of Personality Disorder (SASPD). A total of 110 patients completed the SASPD together with a clinical assessment of the severity of personality disorder. We examined the predictive ability of the SASPD using the area under the ROC curve (AUC). Two to four weeks later, 43 patients repeated the SASPD to examine reliability. The SASPD had good predictive ability for determining mild (AUC = 0.86) and moderate (AUC = 0.84) PD at cut points of 8 and 10, respectively. Test-retest reliability of the SASPD was high (intraclass correlation coefficient = 0.93, 95% CI [0.88, 0.96]). The SASPD thus provides a simple, brief, and reliable indicator of the presence of mild or moderate PD according to ICD-11 criteria.
Tissue tonometry is a simple, objective measure for pliability of burn scar: is it reliable?
Lye, Ian; Edgar, Dale W; Wood, Fiona M; Carroll, Sara
2006-01-01
Objective measurement of burn scar response to treatment is important to facilitate individual patient care, research, and service development. This work examines the validity and reliability of the tonometer as a means of quantifying scar pliability. Ten burn survivors were recruited into the study. Triplicate measures were taken for each of four scar and one normal skin point. The pliability score from the Vancouver Scar Scale also was used as a comparison. The tonometer demonstrated a high degree of reliability (intraclass correlation coefficients 0.91-0.94). It also was shown to provide a valid measure of pliability by quantifying decreased tissue deformation for scar (2.04 +/- 0.45 mm) compared with normal tissue (3.02 +/- 0.92 mm; t = 4.28, P = .004) and a moderate correlation with Vancouver Scar Scale scores. The tissue tonometer provides a repeatable, objective index of burn scar pliability. Using the methods described, it is a simple, clinically useful technique for monitoring an individual's scar.
Hiradfar, Mehran; Shojaeian, Reza; Zabolinejad, Nona; Gharavifard, Mohammad; Sabzevari, Alireza; Joodi, Marjan; Yal, Nazila; Saeedi Sharifabad, Parisa; Hajian, Sara; Nazarzadeh, Reza; Lotfinejad, Nasim
2014-03-01
Giving the ever-rising trend of pediatric minimally invasive surgery besides early neonatal surgical interventions, intestinal anastomosis turns out to be a time consuming stage due to several anatomical as well as technical difficulties. A perfect bowel anastomosis method should be easy, rapid, safe and reliable in creation of bowel continuity with minimal tissue damage. In this light, sutureless anastomotic methods have been introduced, using compression based anastomosis with biofragmentable rings or powerful magnets. Accordingly, this experimental animal model study has evaluated the result of an easy, rapid intestinal sutureless anastomotic technique via simple tying over an intraluminal ring, in comparison with conventional handsewn bowel anastomosis. Thirty Wistar-Albino male rats were enrolled and small bowel was transected via a midline laparotomy. A grooved plastic ring was inserted into the ileal lumen and both intestinal cutting ends were fixed over the ring with a simple tie in the first group. On the other hand, enteroenterostomy was performed by the conventional method of handsewn anastomosis in the second group. After 14 days, rats were sacrificed to evaluate for intraperitoneal adhesion and abscess formation in addition to other evidences of anastomotic leakage. Furthermore, the anastomotic site integrity, tensile strength and healing stage were assessed microscopically. The mean operative time and intraoperative bleeding in the tie over ring group were significantly less than those in the handsewn anastomosis group. Anastomotic stricture was more common in the conventional anastomosis group while the anastomotic tensile strength was significantly higher in the tie over ring group. Histopathological healing parameters and final healing score were almost similar in both groups but mean inflammatory cell infiltration in handsewn anastomosis was significantly higher. "Tie over ring" is a simple method of anastomosis that is feasible, fast, safe and functionally effective for bowel reconstruction in animal models that could be reconsidered in human bowel anastomosis. © 2014.
First demonstration of the fast-to-slow corrector current shift in the NSLS-II storage ring
Yang, Xi; Tian, Yuke; Yu, Li Hua; ...
2018-04-01
In order to realize the full benefits of the high brightness and ultra-small beam sizes of NSLS-II, it is essential that the photon beams are exceedingly stable. In the circumstances of implementing local bumps, changing ID gaps, and long term drifting, the fast orbit feedback (FOFB) requires shifting the fast corrector strengths to the slow correctors to prevent the fast corrector saturation and to make the beam orbit stable in the sub-micron level. As the result, a reliable and precise technique of fast-to-slow corrector strength shift has been developed and tested at NSLS-II. This technique is based on the fastmore » corrector response to the slow corrector change when the FOFB is on. In this article, the shift technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented. The maximum fast corrector current was reduced from greater than 0.45 A to less than 0.04 A with the orbit perturbation within ±1 μm.« less
First demonstration of the fast-to-slow corrector current shift in the NSLS-II storage ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xi; Tian, Yuke; Yu, Li Hua
In order to realize the full benefits of the high brightness and ultra-small beam sizes of NSLS-II, it is essential that the photon beams are exceedingly stable. In the circumstances of implementing local bumps, changing ID gaps, and long term drifting, the fast orbit feedback (FOFB) requires shifting the fast corrector strengths to the slow correctors to prevent the fast corrector saturation and to make the beam orbit stable in the sub-micron level. As the result, a reliable and precise technique of fast-to-slow corrector strength shift has been developed and tested at NSLS-II. This technique is based on the fastmore » corrector response to the slow corrector change when the FOFB is on. In this article, the shift technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented. The maximum fast corrector current was reduced from greater than 0.45 A to less than 0.04 A with the orbit perturbation within ±1 μm.« less
NASA Astrophysics Data System (ADS)
Park, Joonhan; Choi, Yunkyoung; Lee, Myungjae; Jeon, Heonsu; Kim, Sunghwan
2014-12-01
A fully biocompatible plasmonic quasi-3D nanostructure is demonstrated by a simple and reliable fabrication method using strong adhesion between gold and silk fibroin. The quasi-3D nature gives rise to complex photonic responses in reflectance that are prospectively useful in bio/chemical sensing applications. Laser interference lithography is utilized to fabricate large-area plasmonic nanostructures.A fully biocompatible plasmonic quasi-3D nanostructure is demonstrated by a simple and reliable fabrication method using strong adhesion between gold and silk fibroin. The quasi-3D nature gives rise to complex photonic responses in reflectance that are prospectively useful in bio/chemical sensing applications. Laser interference lithography is utilized to fabricate large-area plasmonic nanostructures. Electronic supplementary information (ESI) available: The incident angle dependence of reflectance spectra and the atomic force microscopy image of the Au nanoparticle array on a silk film after 1 hour of ultrasonication. See DOI: 10.1039/c4nr05172f
Visvesvara, G S; Moura, H; Kovacs-Nace, E; Wallace, S; Eberhard, M L
1997-01-01
Cyclospora, a coccidian protist, is increasingly being identified as an important, newly emerging parasite that causes diarrhea, flatulence, fatigue, and abdominal pain leading to weight loss in immunocompetent persons with or without a recent travel history as well as in patients with AIDS. Modified Kinyoun's acid-fast stain is the most commonly used stain to identify the oocyst of this parasite in fecal smears. Oocysts of Cyclospora stain variably by the modified acid-fast procedure, resulting in the possible misidentification of this parasite. We examined fecal smears stained by six different procedures that included Giemsa, trichrome, chromotrope, Gram-chromotrope, acid-fast, and safranin stains. We report on safranin-based stain that uniformly stains oocysts of Cyclospora a brilliant reddish orange, provided that the fecal smears are heated in a microwave oven prior to staining. This staining procedure, besides being superior to acid-fast staining, is fast, reliable, and easy to perform in most clinical laboratories. PMID:9041421
Fast segmentation of satellite images using SLIC, WebGL and Google Earth Engine
NASA Astrophysics Data System (ADS)
Donchyts, Gennadii; Baart, Fedor; Gorelick, Noel; Eisemann, Elmar; van de Giesen, Nick
2017-04-01
Google Earth Engine (GEE) is a parallel geospatial processing platform, which harmonizes access to petabytes of freely available satellite images. It provides a very rich API, allowing development of dedicated algorithms to extract useful geospatial information from these images. At the same time, modern GPUs provide thousands of computing cores, which are mostly not utilized in this context. In the last years, WebGL became a popular and well-supported API, allowing fast image processing directly in web browsers. In this work, we will evaluate the applicability of WebGL to enable fast segmentation of satellite images. A new implementation of a Simple Linear Iterative Clustering (SLIC) algorithm using GPU shaders will be presented. SLIC is a simple and efficient method to decompose an image in visually homogeneous regions. It adapts a k-means clustering approach to generate superpixels efficiently. While this approach will be hard to scale, due to a significant amount of data to be transferred to the client, it should significantly improve exploratory possibilities and simplify development of dedicated algorithms for geoscience applications. Our prototype implementation will be used to improve surface water detection of the reservoirs using multispectral satellite imagery.
Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents.
Zimmermann, Stefan; Barth, Sebastian; Baether, Wolfgang K M; Ringer, Joachim
2008-09-01
Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. In particular, there is an increasing demand for miniaturized low-cost IMS for hand-held devices and air monitoring of public areas by sensor networks. In this paper, we present a miniaturized aspiration condenser type ion mobility spectrometer for fast detection of chemical warfare agents. The device is easy to manufacture and allows single substance identification down to low part per billion-level concentrations within seconds. The improved separation power results from ion focusing by means of geometric constraints and fluid dynamics. A simple pattern recognition algorithm is used for the identification of trained substances in air. The device was tested at the German Armed Forces Scientific Institute for Protection Technologies-NBC-Protection. Different chemical warfare agents, such as sarin, tabun, soman, US-VX, sulfur mustard, nitrogen mustard, and lewisite were tested. The results are presented here.
NASA Astrophysics Data System (ADS)
Moriyama, S.; Kajiwara, K.; Takahashi, K.; Kasugai, A.; Seki, M.; Ikeda, Y.; Fujii, T.
2005-11-01
A compact antenna system was designed and fabricated to enable millimeter-wave beam scanning in the toroidal and poloidal directions of the JT-60U tokamak for electron cyclotron heating (ECH) and electron cyclotron current drive (ECCD) experiments. The antenna consists of a fast movable flat mirror mounted on the tokamak vacuum vessel and a rotary focusing mirror attached at the end of the waveguide that is supported from outside the vacuum vessel. This separate support concept enables a compact structure inside a shallow port (0.68×0.54×0.2m) that is shared with a subport for an independent diagnostic system. During a plasma shot, the flat mirror is driven by a servomotor with a 3-m-long drive shaft to reduce the influence of the high magnetic field on the motor. The focusing mirror is rotated by a simple mechanism utilizing a push rod and an air cylinder. The antenna has been operated reliably for 3 years after a small improvement to the rotary drive mechanism. It has made significant contributions to ECH and ECCD experiments, especially the current profile control in JT-60U.
A combined vision-inertial fusion approach for 6-DoF object pose estimation
NASA Astrophysics Data System (ADS)
Li, Juan; Bernardos, Ana M.; Tarrío, Paula; Casar, José R.
2015-02-01
The estimation of the 3D position and orientation of moving objects (`pose' estimation) is a critical process for many applications in robotics, computer vision or mobile services. Although major research efforts have been carried out to design accurate, fast and robust indoor pose estimation systems, it remains as an open challenge to provide a low-cost, easy to deploy and reliable solution. Addressing this issue, this paper describes a hybrid approach for 6 degrees of freedom (6-DoF) pose estimation that fuses acceleration data and stereo vision to overcome the respective weaknesses of single technology approaches. The system relies on COTS technologies (standard webcams, accelerometers) and printable colored markers. It uses a set of infrastructure cameras, located to have the object to be tracked visible most of the operation time; the target object has to include an embedded accelerometer and be tagged with a fiducial marker. This simple marker has been designed for easy detection and segmentation and it may be adapted to different service scenarios (in shape and colors). Experimental results show that the proposed system provides high accuracy, while satisfactorily dealing with the real-time constraints.
Santos, Inês C; Martin, Misty S; Carlton, Doug D; Amorim, Catarina L; Castro, Paula M L; Hildenbrand, Zacariah L; Schug, Kevin A
2017-08-10
Groundwater quality and quantity is of extreme importance as it is a source of drinking water in the United States. One major concern has emerged due to the possible contamination of groundwater from unconventional oil and natural gas extraction activities. Recent studies have been performed to understand if these activities are causing groundwater contamination, particularly with respect to exogenous hydrocarbons and volatile organic compounds. The impact of contaminants on microbial ecology is an area to be explored as alternatives for water treatment are necessary. In this work, we identified cultivable organic-degrading bacteria in groundwater in close proximity to unconventional natural gas extraction. Pseudomonas stutzeri and Acinetobacter haemolyticus were identified using matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (MALDI-TOF MS), which proved to be a simple, fast, and reliable method. Additionally, the potential use of the identified bacteria in water and/or wastewater bioremediation was studied by determining the ability of these microorganisms to degrade toluene and chloroform. In fact, these bacteria can be potentially applied for in situ bioremediation of contaminated water and wastewater treatment, as they were able to degrade both compounds.
Clinical determination of glucose in human serum by a tomato skin biosensor.
Han, Hui; Li, Yi; Yue, Huan; Zhou, Zaide; Xiao, Dan; Choi, Martin M F
2008-09-01
Glucose biosensors based on enzyme reaction of glucose oxidase were studied because the symptomatic therapy of diabetes mellitus requires reliable assessment of blood glucose level at frequent intervals. Tomato skin membranes have been successfully employed to entrap glucose oxidase for fabrication of glucose biosensor. Glucose oxidase was immobilized onto the tomato skin and the enzyme membrane was then positioned on the surface of an oxygen electrode. The glucose concentration was quantified by the change of dissolved oxygen. All the serum samples were also simultaneously determined by a Hitachi 7060 chemistry analyzer. The response of the biosensor showed a linear relationship with a concentration range of 1.0-30.0 mmol/l glucose. The limit of detection was 0.20 mmol/l. Error Grid analysis demonstrated that 100% of the results fell within clinically acceptable zones A and B. The F- and t-tests showed no significant differences between the 2 methods. The recovery was 95.0-110.0% for 30 serum samples analysis. The tomato skin biosensor possesses the advantages of simple fabrication, fast response time, low cost and high sensitivity. The results of our method are more accurate than and match well with the current clinical instrument method.
Li, Ming; de Graaf, Inge A M; Groothuis, Geny M M
2016-01-01
The absorption, distribution, metabolism, excretion and toxicity (ADME-tox) processes of drugs are of importance and require preclinical investigation intestine in addition to the liver. Various models have been developed for prediction of ADME-tox in the intestine. In this review, precision-cut intestinal slices (PCIS) are discussed and highlighted as model for ADME-tox studies. This review provides an overview of the applications and an update of the most recent research on PCIS as an ex vivo model to study the transport, metabolism and toxicology of drugs and other xenobiotics. The unique features of PCIS and the differences with other models as well as the translational aspects are also discussed. PCIS are a simple, fast, and reliable ex vivo model for drug ADME-tox research. Therefore, PCIS are expected to become an indispensable link in the in vitro-ex vivo-in vivo extrapolation, and a bridge in translation of animal data to the human situation. In the future, this model may be helpful to study the effects of interorgan interactions, intestinal bacteria, excipients and drug formulations on the ADME-tox properties of drugs. The optimization of culture medium and the development of a (cryo)preservation technique require more research.
Yu, Xiao-Guang; Li, Yuan-Qing; Zhu, Wei-Bin; Huang, Pei; Wang, Tong-Tong; Hu, Ning; Fu, Shao-Yun
2017-05-25
Melamine sponge, also known as nano-sponge, is widely used as an abrasive cleaner in our daily life. In this work, the fabrication of a wearable strain sensor for human motion detection is first demonstrated with a commercially available nano-sponge as a starting material. The key resistance sensitive material in the wearable strain sensor is obtained by the encapsulation of a carbonized nano-sponge (CNS) with silicone resin. The as-fabricated CNS/silicone sensor is highly sensitive to strain with a maximum gauge factor of 18.42. In addition, the CNS/silicone sensor exhibits a fast and reliable response to various cyclic loading within a strain range of 0-15% and a loading frequency range of 0.01-1 Hz. Finally, the CNS/silicone sensor as a wearable device for human motion detection including joint motion, eye blinking, blood pulse and breathing is demonstrated by attaching the sensor to the corresponding parts of the human body. In consideration of the simple fabrication technique, low material cost and excellent strain sensing performance, the CNS/silicone sensor is believed to have great potential in the next-generation of wearable devices for human motion detection.
Bakircioglu, Dilek; Kurtulus, Yasemin Bakircioglu; Yurtsever, Selcuk
2013-06-01
The content of elements (Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn) in edible oils (sunflower, hazelnut, canola, corn and olive oils) from Turkey was determined using inductively coupled plasma optical emission spectrometry (ICP-OES) after ultrasonic extraction, wet digestion, and extraction induced by emulsion breaking procedures (EIEB). In order to evaluate the best sample preparation procedure, EIEB procedure was compared by ultrasonic extraction and wet digestion procedures. The results in the samples (minimum-maximum in mgkg(-1)) were : 0.022-0.058, Cr 0.126-7.106, Cu 0.570-4.504, Fe 8.004-12.588, Mn 0.035-0.054, Ni 0.908-2.182, Pb 0.099-0.134 and Zn 2.206-8.982. The EIEB procedure was found to be fast, reliable, simple, and excellent in comparison with the other studied procedures. The recovery test was performed by spiking the samples with known amounts of the metals in the form of organometallic standards and applying the EIEB procedure. The recoveries were in the range of 96-109%. Copyright © 2012 Elsevier Ltd. All rights reserved.
Martin, Misty S.; Carlton, Doug D.; Castro, Paula M. L.; Hildenbrand, Zacariah L.; Schug, Kevin A.
2017-01-01
Groundwater quality and quantity is of extreme importance as it is a source of drinking water in the United States. One major concern has emerged due to the possible contamination of groundwater from unconventional oil and natural gas extraction activities. Recent studies have been performed to understand if these activities are causing groundwater contamination, particularly with respect to exogenous hydrocarbons and volatile organic compounds. The impact of contaminants on microbial ecology is an area to be explored as alternatives for water treatment are necessary. In this work, we identified cultivable organic-degrading bacteria in groundwater in close proximity to unconventional natural gas extraction. Pseudomonas stutzeri and Acinetobacter haemolyticus were identified using matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (MALDI-TOF MS), which proved to be a simple, fast, and reliable method. Additionally, the potential use of the identified bacteria in water and/or wastewater bioremediation was studied by determining the ability of these microorganisms to degrade toluene and chloroform. In fact, these bacteria can be potentially applied for in situ bioremediation of contaminated water and wastewater treatment, as they were able to degrade both compounds. PMID:28796186
Brandon, Esther F A; Oomen, Agnes G; Rompelberg, Cathy J M; Versantvoort, Carolien H M; van Engelen, Jacqueline G M; Sips, Adrienne J A M
2006-03-01
This paper describes the applicability of in vitro digestion models as a tool for consumer products in (ad hoc) risk assessment. In current risk assessment, oral bioavailability from a specific product is considered to be equal to bioavailability found in toxicity studies in which contaminants are usually ingested via liquids or food matrices. To become bioavailable, contaminants must first be released from the product during the digestion process (i.e. become bioaccessible). Contaminants in consumer products may be less bioaccessible than contaminants in liquid or food. Therefore, the actual risk after oral exposure could be overestimated. This paper describes the applicability of a simple, reliable, fast and relatively inexpensive in vitro method for determining the bioaccessibility of a contaminant from a consumer product. Different models, representing sucking and/or swallowing were developed. The experimental design of each model can be adjusted to the appropriate exposure scenarios as determined by the risk assessor. Several contaminated consumer products were tested in the various models. Although relevant in vivo data are scare, we succeeded to preliminary validate the model for one case. This case showed good correlation and never underestimated the bioavailability. However, validation check needs to be continued.
Neuromorphic computing with nanoscale spintronic oscillators
Torrejon, Jacob; Riou, Mathieu; Araujo, Flavio Abreu; Tsunegi, Sumito; Khalsa, Guru; Querlioz, Damien; Bortolotti, Paolo; Cros, Vincent; Fukushima, Akio; Kubota, Hitoshi; Yuasa, Shinji; Stiles, M. D.; Grollier, Julie
2017-01-01
Neurons in the brain behave as non-linear oscillators, which develop rhythmic activity and interact to process information1. Taking inspiration from this behavior to realize high density, low power neuromorphic computing will require huge numbers of nanoscale non-linear oscillators. Indeed, a simple estimation indicates that, in order to fit a hundred million oscillators organized in a two-dimensional array inside a chip the size of a thumb, their lateral dimensions must be smaller than one micrometer. However, despite multiple theoretical proposals2–5, and several candidates such as memristive6 or superconducting7 oscillators, there is no proof of concept today of neuromorphic computing with nano-oscillators. Indeed, nanoscale devices tend to be noisy and to lack the stability required to process data in a reliable way. Here, we show experimentally that a nanoscale spintronic oscillator8,9 can achieve spoken digit recognition with accuracies similar to state of the art neural networks. We pinpoint the regime of magnetization dynamics leading to highest performance. These results, combined with the exceptional ability of these spintronic oscillators to interact together, their long lifetime, and low energy consumption, open the path to fast, parallel, on-chip computation based on networks of oscillators. PMID:28748930
A Radiation-Tolerant, Low-Power Non-Volatile Memory Based on Silicon Nanocrystal Quantum Dots
NASA Technical Reports Server (NTRS)
Bell, L. D.; Boer, E. A.; Ostraat, M. L.; Brongersma, M. L.; Flagan, R. C.; Atwater, H. A.; deBlauwe, J.; Green, M. L.
2001-01-01
Nanocrystal nonvolatile floating-gate memories are a good candidate for space applications - initial results suggest they are fast, more reliable and consume less power than conventional floating gate memories. In the nanocrystal based NVM device, charge is not stored on a continuous polysilicon layer (so-called floating gate), but instead on a layer of discrete nanocrystals. Charge injection and storage in dense arrays of silicon nanocrystals in SiO2 is a critical aspect of the performance of potential nanocrystal flash memory structures. The ultimate goal for this class of devices is few- or single-electron storage in a small number of nanocrystal elements. In addition, the nanocrystal layer fabrication technique should be simple, 8-inch wafer compatible and well controlled in program/erase threshold voltage swing was seen during 100,000 program and erase cycles. Additional near-term goals for this project include extensive testing for radiation hardness and the development of artificial layered tunnel barrier heterostructures which have the potential for large speed enhancements for read/write of nanocrystal memory elements, compared with conventional flash devices. Additional information is contained in the original extended abstract.
Rower, Joseph E.; Bushman, Lane R.; Hammond, Kyle P.; Kadam, Rajendra S.; Aquilante, Christina L.
2011-01-01
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate, and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6% and 10.7%, and inter-assay precision ranging from 4.4% to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6% and 108.7% of the expected value, and inter-assay concentrations within 89.4 to 104.0% of the expected value. The linear concentration range was between 0.5 and 50 μg/mL with a lower limit of quantitation of 0.5 μg/mL when 125 μL of plasma were extracted. This LC/MS method yielded a quick, simple, and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. PMID:21077249
Rower, Joseph E; Bushman, Lane R; Hammond, Kyle P; Kadam, Rajendra S; Aquilante, Christina L
2010-12-01
Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6 and 10.7%, and inter-assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6-108.7% of the expected value, and inter-assay concentrations within 89.4-104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.
Long, Hu; Harley-Trochimczyk, Anna; Cheng, Siyi; Hu, Hao; Chi, Won Seok; Rao, Ameya; Carraro, Carlo; Shi, Tielin; Tang, Zirong; Maboudian, Roya
2016-11-23
Nanowire-assembled 3D hierarchical ZnCo 2 O 4 microstructure is synthesized by a facile hydrothermal route and a subsequent annealing process. In comparison to simple nanowires, the resulting dandelion-like structure yields more open spaces between nanowires, which allow for better gas diffusion and provide more active sites for gas adsorption while maintaining good electrical conductivity. The hierarchical ZnCo 2 O 4 microstructure is integrated on a low-power microheater platform without using binders or conductive additives. The hierarchical structure of the ZnCo 2 O 4 sensing material provides reliable electrical connection across the sensing electrodes. The resulting sensor exhibits an ultralow detection limit of 3 ppb toward formaldehyde with fast response and recovery as well as good selectivity to CO, H 2 , and hydrocarbons such as n-pentane, propane, and CH 4 . The sensor only consumes ∼5.7 mW for continuous operation at 300 °C with good long-term stability. The excellent sensing performance of this hierarchical structure based sensor suggests the advantages of combining such structures with microfabricated heaters for practical low-power sensing applications.
Current State of the Art Historic Building Information Modelling
NASA Astrophysics Data System (ADS)
Dore, C.; Murphy, M.
2017-08-01
In an extensive review of existing literature a number of observations were made in relation to the current approaches for recording and modelling existing buildings and environments: Data collection and pre-processing techniques are becoming increasingly automated to allow for near real-time data capture and fast processing of this data for later modelling applications. Current BIM software is almost completely focused on new buildings and has very limited tools and pre-defined libraries for modelling existing and historic buildings. The development of reusable parametric library objects for existing and historic buildings supports modelling with high levels of detail while decreasing the modelling time. Mapping these parametric objects to survey data, however, is still a time-consuming task that requires further research. Promising developments have been made towards automatic object recognition and feature extraction from point clouds for as-built BIM. However, results are currently limited to simple and planar features. Further work is required for automatic accurate and reliable reconstruction of complex geometries from point cloud data. Procedural modelling can provide an automated solution for generating 3D geometries but lacks the detail and accuracy required for most as-built applications in AEC and heritage fields.
High-Throughput Fabrication of Flexible and Transparent All-Carbon Nanotube Electronics.
Chen, Yong-Yang; Sun, Yun; Zhu, Qian-Bing; Wang, Bing-Wei; Yan, Xin; Qiu, Song; Li, Qing-Wen; Hou, Peng-Xiang; Liu, Chang; Sun, Dong-Ming; Cheng, Hui-Ming
2018-05-01
This study reports a simple and effective technique for the high-throughput fabrication of flexible all-carbon nanotube (CNT) electronics using a photosensitive dry film instead of traditional liquid photoresists. A 10 in. sized photosensitive dry film is laminated onto a flexible substrate by a roll-to-roll technology, and a 5 µm pattern resolution of the resulting CNT films is achieved for the construction of flexible and transparent all-CNT thin-film transistors (TFTs) and integrated circuits. The fabricated TFTs exhibit a desirable electrical performance including an on-off current ratio of more than 10 5 , a carrier mobility of 33 cm 2 V -1 s -1 , and a small hysteresis. The standard deviations of on-current and mobility are, respectively, 5% and 2% of the average value, demonstrating the excellent reproducibility and uniformity of the devices, which allows constructing a large noise margin inverter circuit with a voltage gain of 30. This study indicates that a photosensitive dry film is very promising for the low-cost, fast, reliable, and scalable fabrication of flexible and transparent CNT-based integrated circuits, and opens up opportunities for future high-throughput CNT-based printed electronics.
Commissioning and validation of COMPASS system for VMAT patient specific quality assurance
NASA Astrophysics Data System (ADS)
Pimthong, J.; Kakanaporn, C.; Tuntipumiamorn, L.; Laojunun, P.; Iampongpaiboon, P.
2016-03-01
Pre-treatment patient specific quality assurance (QA) of advanced treatment techniques such as volumetric modulated arc therapy (VMAT) is one of important QA in radiotherapy. The fast and reliable dosimetric device is required. The objective of this study is to commission and validate the performance of COMPASS system for dose verification of VMAT technique. The COMPASS system is composed of an array of ionization detectors (MatriXX) mounted to the gantry using a custom holder and software for the analysis and visualization of QA results. We validated the COMPASS software for basic and advanced clinical application. For the basic clinical study, the simple open field in various field sizes were validated in homogeneous phantom. And the advanced clinical application, the fifteen prostate and fifteen nasopharyngeal cancers VMAT plans were chosen to study. The treatment plans were measured by the MatriXX. The doses and dose-volume histograms (DVHs) reconstructed from the fluence measurements were compared to the TPS calculated plans. And also, the doses and DVHs computed using collapsed cone convolution (CCC) Algorithm were compared with Eclipse TPS calculated plans using Analytical Anisotropic Algorithm (AAA) that according to dose specified in ICRU 83 for PTV.
Shuttle-Data-Tape XML Translator
NASA Technical Reports Server (NTRS)
Barry, Matthew R.; Osborne, Richard N.
2005-01-01
JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.
A Simple Method for Nucleon-Nucleon Cross Sections in a Nucleus
NASA Technical Reports Server (NTRS)
Tripathi, R. K.; Cucinotta, Francis A.; Wilson, John W.
1999-01-01
A simple reliable formalism is presented for obtaining nucleon-nucleon cross sections within a nucleus in nuclear collisions for a given projectile and target nucleus combination at a given energy for use in transport, Monte Carlo, and other calculations. The method relies on extraction of these values from experiments and has been tested and found to give excellent results.
McGlade, D P; Poon, A B; Davies, M J
2001-10-01
We aimed to assess the reliability of patients as historians in terms of the self assessment of functional capacity and also examined the usefulness of a simple ward exercise tolerance test. One hundred consecutive elective vascular surgery patients were interviewed preoperatively using a modified Duke Activity Status Index (DASI) questionnaire. To test reliability in reference to an independent observer, the questionnaire concerning the patient was also applied to each patient's closest relative who was blinded to the patient's responses. Patients were then asked to walk up two flights of stairs and the time taken to complete the task or the reason for failing to complete the task was recorded. The D
Advanced Joining of Aerospace Metallic Materials.
1986-07-01
uniaxial tensile test with varying temperature and cyclic loading. This simple test problem excercises maray aspects of the phenomena. suOn- ,Ual Yield...6vidence Ia seconde configuration apparait plus n~ faste . 5.3. Ents-e-igne-men-t-s s-u r a dyna-mique de. bain-s de fu-sion A lusage il svest r~vle que la...scanning system for fast and exact alignment of the EB-qun is used. In a fixture the cleaned detail parts are positioned exactly and clamped for welding. At
Akram, M Nadeem; Tong, Zhaomin; Ouyang, Guangmin; Chen, Xuyuan; Kartashov, Vladimir
2010-06-10
We utilize spatial and angular diversity to achieve speckle reduction in laser illumination. Both free-space and imaging geometry configurations are considered. A fast two-dimensional scanning micromirror is employed to steer the laser beam. A simple experimental setup is built to demonstrate the application of our technique in a two-dimensional laser picture projection. Experimental results show that the speckle contrast factor can be reduced down to 5% within the integration time of the detector.
ERIC Educational Resources Information Center
Anderson, James L.; And Others
1980-01-01
Presents an undergraduate quantitative analysis experiment, describing an atomic absorption quantitation scheme that is fast, sensitive and comparatively simple relative to other titration experiments. (CS)
NASA Technical Reports Server (NTRS)
Ross, H. Richard; Bourgeois, Chris M.
1995-01-01
Apparatus continuously monitors concentration of hydrogen, at level ranging from few parts per million to several percent, in mixture of gases. Simple and fast, providing high sensitivity and linear response. Used to alert technicians to potentially explosive concentrations of residual hydrogen.
Hyun Kim; Sun-Young Yoo; Ji Sung Kim; Zihuan Wang; Woon Hee Lee; Kyo-In Koo; Jong-Mo Seo; Dong-Il Cho
2017-07-01
Inhibition of polydimethylsiloxane (PDMS) polymerization could be observed when spin-coated over vinyl substrates. The degree of polymerization, partially curing or fully curing, depended on the PDMS thickness coated over the vinyl substrate. This characteristic was exploited to achieve simple and fast PDMS patterning method using a vinyl adhesive layer patterned through a cutting plotter. The proposed patterning method showed results resembling PDMS etching. Therefore, patterning PDMS over PDMS, glass, silicon, and gold substrates were tested to compare the results with conventional etching methods. Vinyl stencils with widths ranging from 200μm to 1500μm were used for the procedure. To evaluate the accuracy of the cutting plotter, stencil designed on the AutoCAD software and the actual stencil widths were compared. Furthermore, this method's accuracy was also evaluated by comparing the widths of the actual stencils and etched PDMS results.
Skinner, Asheley Cockrell; Perrin, Eliana M.
2011-01-01
BACKGROUND: There are barriers to fasting lipid screening for at-risk children. Results of studies in adults have suggested that lipid testing might be reliably performed without fasting. OBJECTIVE: To examine population-level differences in pediatric lipid values based on length of fast before testing. METHODS: We used the National Health and Nutrition Examination Survey (1999–2008) to examine total cholesterol (TC), HDL (high-density lipoprotein), LDL (low-density lipoprotein), and triglyceride cholesterol components on the basis of the period of fasting. Young children fasted for varying times before being tested, and children older than 12 years were asked to fast; however, adherence was variable. We used ordinary least-squares regression to test for differences in lipid values that were based on fasting times, controlling for weight status, age, race, ethnicity, and gender. RESULTS: TC, HDL, LDL, or triglyceride values were available for 12 744 children. Forty-eight percent of the TC and HDL samples and 80% of the LDL and triglyceride samples were collected from children who had fasted ≥8 hours. Fasting had a small positive effect for TC, HDL, and LDL, resulting in a mean value for the sample that was 2 to 5 mg/dL higher with a 12-hour fast compared with a no-fast sample. Fasting time had a negative effect on triglycerides (β = −0.859; P = .02), which resulted in values in the fasting group that were 7 mg/dL lower. DISCUSSION: Comparison of cholesterol screening results for a nonfasting group of children compared with results for a similar fasting group resulted in small differences that are likely not clinically important. Physicians might be able to decrease the burden of childhood cholesterol screening by not requiring prescreening fasting for these components. PMID:21807697
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Dongxiao; Shan, Lianqiang; Zhou, Weimin
During fast-ignition implosions, preheating of inside the cone tip caused by hard X-rays can strongly affect the generation and transport of hot electrons in the cone. Although indirect-drive implosions have a higher implosion symmetry, they cause stronger preheating effects than direct-drive implosions. To control the preheating of the cone tip, we propose the use of indirect-drive fast-ignition targets with thicker tips. Experiments carried out at the ShenGuang-III prototype laser facility confirmed that thicker tips are effective for controlling preheating. Moreover, these results were consistent with those of 1D radiation hydrodynamic simulations.
Nanopore Technology: A Simple, Inexpensive, Futuristic Technology for DNA Sequencing.
Gupta, P D
2016-10-01
In health care, importance of DNA sequencing has been fully established. Sanger's Capillary Electrophoresis DNA sequencing methodology is time consuming, cumbersome, hence become more expensive. Lately, because of its versatility DNA sequencing became house hold name, and therefore, there is an urgent need of simple, fast, inexpensive, DNA sequencing technology. In the beginning of this century efforts were made, and Nanopore DNA sequencing technology was developed; still it is infancy, nevertheless, it is the futuristic technology.
Focused Ion Beam Fabrication of Microelectronic Structures
1990-12-01
a simple function generator and allows fast ing, the pressure measured by the capacitance manometer is equal to the pressure at the sample surface...height above the sample ties. In practice this restricts features to simple rectangles or surface. J. Vac. . Tedhnol. B, VOL 7, No. 4, Jul/Aug IM...the sample up to 300 keV are available.(2) -3- This higher energy is often needed for implantation and for lithography in thick resist. Be++ ions at
NASA Astrophysics Data System (ADS)
Donahue, William; Newhauser, Wayne D.; Ziegler, James F.
2016-09-01
Many different approaches exist to calculate stopping power and range of protons and heavy charged particles. These methods may be broadly categorized as physically complete theories (widely applicable and complex) or semi-empirical approaches (narrowly applicable and simple). However, little attention has been paid in the literature to approaches that are both widely applicable and simple. We developed simple analytical models of stopping power and range for ions of hydrogen, carbon, iron, and uranium that spanned intervals of ion energy from 351 keV u-1 to 450 MeV u-1 or wider. The analytical models typically reproduced the best-available evaluated stopping powers within 1% and ranges within 0.1 mm. The computational speed of the analytical stopping power model was 28% faster than a full-theoretical approach. The calculation of range using the analytic range model was 945 times faster than a widely-used numerical integration technique. The results of this study revealed that the new, simple analytical models are accurate, fast, and broadly applicable. The new models require just 6 parameters to calculate stopping power and range for a given ion and absorber. The proposed model may be useful as an alternative to traditional approaches, especially in applications that demand fast computation speed, small memory footprint, and simplicity.
Development of longitudinally excited CO2 laser
NASA Astrophysics Data System (ADS)
Masroon, N. S.; Tanaka, M.; Tei, M.; Uno, K.; Tsuyama, M.; Nakano, H.
2018-05-01
Simple, compact, and affordable discharged-pumped CO2 laser controlled by a fast high voltage solid state switch has been developed. In this study, longitudinal excitation scheme has been adapted for simple configuration. In the longitudinal excitation scheme, the discharge is produced along the direction of the laser axis, and the electrodes are well separated with a small discharge cross-section. Triggered spark gap switch is usually used to switch out the high voltage because of simple and low cost. However, the triggered spark gap operates in the arc mode and suffer from recovery problem causing a short life time and low efficiency for high repetition rate operation. As a result, there is now considerable interest in replacing triggered spark gap switch with solid state switches. Solid state switches have significant advantages compared to triggered spark gap switch which include longer service lifetime, low cost and stable high trigger pulse. We have developed simple and low cost fast high voltage solid state switch that consists of series connected-MOSFETs. It has been installed to the longitudinally excited CO2 laser to realize the gap switch less operation. Characteristics of laser oscillation by varying the discharge length, charging voltage, capacitance and gas pressure have been evaluated. Longer discharge length produce high power of laser oscillation. Optimum charging voltage and gas pressure were existed for longitudinally excited CO2 laser.
Donahue, William; Newhauser, Wayne D; Ziegler, James F
2016-09-07
Many different approaches exist to calculate stopping power and range of protons and heavy charged particles. These methods may be broadly categorized as physically complete theories (widely applicable and complex) or semi-empirical approaches (narrowly applicable and simple). However, little attention has been paid in the literature to approaches that are both widely applicable and simple. We developed simple analytical models of stopping power and range for ions of hydrogen, carbon, iron, and uranium that spanned intervals of ion energy from 351 keV u(-1) to 450 MeV u(-1) or wider. The analytical models typically reproduced the best-available evaluated stopping powers within 1% and ranges within 0.1 mm. The computational speed of the analytical stopping power model was 28% faster than a full-theoretical approach. The calculation of range using the analytic range model was 945 times faster than a widely-used numerical integration technique. The results of this study revealed that the new, simple analytical models are accurate, fast, and broadly applicable. The new models require just 6 parameters to calculate stopping power and range for a given ion and absorber. The proposed model may be useful as an alternative to traditional approaches, especially in applications that demand fast computation speed, small memory footprint, and simplicity.