Xu, Chonggang; Gertner, George
2013-01-01
Fourier Amplitude Sensitivity Test (FAST) is one of the most popular uncertainty and sensitivity analysis techniques. It uses a periodic sampling approach and a Fourier transformation to decompose the variance of a model output into partial variances contributed by different model parameters. Until now, the FAST analysis is mainly confined to the estimation of partial variances contributed by the main effects of model parameters, but does not allow for those contributed by specific interactions among parameters. In this paper, we theoretically show that FAST analysis can be used to estimate partial variances contributed by both main effects and interaction effects of model parameters using different sampling approaches (i.e., traditional search-curve based sampling, simple random sampling and random balance design sampling). We also analytically calculate the potential errors and biases in the estimation of partial variances. Hypothesis tests are constructed to reduce the effect of sampling errors on the estimation of partial variances. Our results show that compared to simple random sampling and random balance design sampling, sensitivity indices (ratios of partial variances to variance of a specific model output) estimated by search-curve based sampling generally have higher precision but larger underestimations. Compared to simple random sampling, random balance design sampling generally provides higher estimation precision for partial variances contributed by the main effects of parameters. The theoretical derivation of partial variances contributed by higher-order interactions and the calculation of their corresponding estimation errors in different sampling schemes can help us better understand the FAST method and provide a fundamental basis for FAST applications and further improvements. PMID:24143037
Xu, Chonggang; Gertner, George
2011-01-01
Fourier Amplitude Sensitivity Test (FAST) is one of the most popular uncertainty and sensitivity analysis techniques. It uses a periodic sampling approach and a Fourier transformation to decompose the variance of a model output into partial variances contributed by different model parameters. Until now, the FAST analysis is mainly confined to the estimation of partial variances contributed by the main effects of model parameters, but does not allow for those contributed by specific interactions among parameters. In this paper, we theoretically show that FAST analysis can be used to estimate partial variances contributed by both main effects and interaction effects of model parameters using different sampling approaches (i.e., traditional search-curve based sampling, simple random sampling and random balance design sampling). We also analytically calculate the potential errors and biases in the estimation of partial variances. Hypothesis tests are constructed to reduce the effect of sampling errors on the estimation of partial variances. Our results show that compared to simple random sampling and random balance design sampling, sensitivity indices (ratios of partial variances to variance of a specific model output) estimated by search-curve based sampling generally have higher precision but larger underestimations. Compared to simple random sampling, random balance design sampling generally provides higher estimation precision for partial variances contributed by the main effects of parameters. The theoretical derivation of partial variances contributed by higher-order interactions and the calculation of their corresponding estimation errors in different sampling schemes can help us better understand the FAST method and provide a fundamental basis for FAST applications and further improvements.
Simple, Fast, and Sensitive Method for Quantification of Tellurite in Culture Media▿
Molina, Roberto C.; Burra, Radhika; Pérez-Donoso, José M.; Elías, Alex O.; Muñoz, Claudia; Montes, Rebecca A.; Chasteen, Thomas G.; Vásquez, Claudio C.
2010-01-01
A fast, simple, and reliable chemical method for tellurite quantification is described. The procedure is based on the NaBH4-mediated reduction of TeO32− followed by the spectrophotometric determination of elemental tellurium in solution. The method is highly reproducible, is stable at different pH values, and exhibits linearity over a broad range of tellurite concentrations. PMID:20525868
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Dohoon; Lee, Jinwoo; Kim, Jungbae
2005-12-05
We fabricated a highly sensitive and fast glucose biosensor by simply immobilizing glucose oxidase in mesocellular carbon foam. Due to its unique structure, the MSU-F-C enabled high enzyme loading without serious mass transfer limitation, resulting in high catalytic efficiency. As a result, the glucose biosensor fabricated with MSU-F-C/GOx showed a high sensitivity and fast response. Given these results and the inherent electrical conductivity, we anticipate that MSU-F-C will make a useful matrix for enzyme immobilization in various biocatalytic and electrobiocatalytic applications.
USDA-ARS?s Scientific Manuscript database
There is a need for simple surrogate estimates of insulin sensitivity in epidemiological studies of obese youth because the hyperinsulinemic-euglycemic clamp is not feasible on a large scale. Objectives: (i) To examine the triglyceride glucose (TyG) index (Ln[fasting triglycerides (mg/dL)'×'fasting ...
Lima, Fabricio O.; Silva, Gisele S.; Furie, Karen L.; Frankel, Michael R.; Lev, Michael H.; Camargo, Érica CS; Haussen, Diogo C.; Singhal, Aneesh B.; Koroshetz, Walter J.; Smith, Wade S.; Nogueira, Raul G.
2016-01-01
Background and Purpose Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. Methods The FAST-ED scale was based on items of the NIHSS with higher predictive value for LVOS and tested in the STOPStroke cohort, in which patients underwent CT angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial-ICA, MCA-M1, MCA-2, or basilar arteries. Patients with partial, bi-hemispheric, and/or anterior + posterior circulation occlusions were excluded. Receiver operating characteristic (ROC) curve, sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of FAST-ED were compared with the NIHSS, Rapid Arterial oCclusion Evaluation (RACE) scale and Cincinnati Prehospital Stroke Severity Scale (CPSSS). Results LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the ROC curve: FAST-ED=0.81 as reference; NIHSS=0.80, p=0.28; RACE=0.77, p=0.02; and CPSS=0.75, p=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity 0.89, PPV 0.72, and NPV 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, 0.79 and CPSS ≥2 of 0.56, 0.85, 0.65, 0.78, respectively. Conclusions FAST-ED is a simple scale that if successfully validated in the field may be used by medical emergency professionals to identify LVOS in the pre-hospital setting enabling rapid triage of patients. PMID:27364531
Cacho, J; Sevillano, J; de Castro, J; Herrera, E; Ramos, M P
2008-11-01
Insulin resistance plays a role in the pathogenesis of diabetes, including gestational diabetes. The glucose clamp is considered the gold standard for determining in vivo insulin sensitivity, both in human and in animal models. However, the clamp is laborious, time consuming and, in animals, requires anesthesia and collection of multiple blood samples. In human studies, a number of simple indexes, derived from fasting glucose and insulin levels, have been obtained and validated against the glucose clamp. However, these indexes have not been validated in rats and their accuracy in predicting altered insulin sensitivity remains to be established. In the present study, we have evaluated whether indirect estimates based on fasting glucose and insulin levels are valid predictors of insulin sensitivity in nonpregnant and 20-day-pregnant Wistar and Sprague-Dawley rats. We have analyzed the homeostasis model assessment of insulin resistance (HOMA-IR), the quantitative insulin sensitivity check index (QUICKI), and the fasting glucose-to-insulin ratio (FGIR) by comparing them with the insulin sensitivity (SI(Clamp)) values obtained during the hyperinsulinemic-isoglycemic clamp. We have performed a calibration analysis to evaluate the ability of these indexes to accurately predict insulin sensitivity as determined by the reference glucose clamp. Finally, to assess the reliability of these indexes for the identification of animals with impaired insulin sensitivity, performance of the indexes was analyzed by receiver operating characteristic (ROC) curves in Wistar and Sprague-Dawley rats. We found that HOMA-IR, QUICKI, and FGIR correlated significantly with SI(Clamp), exhibited good sensitivity and specificity, accurately predicted SI(Clamp), and yielded lower insulin sensitivity in pregnant than in nonpregnant rats. Together, our data demonstrate that these indexes provide an easy and accurate measure of insulin sensitivity during pregnancy in the rat.
Lima, Fabricio O; Silva, Gisele S; Furie, Karen L; Frankel, Michael R; Lev, Michael H; Camargo, Érica C S; Haussen, Diogo C; Singhal, Aneesh B; Koroshetz, Walter J; Smith, Wade S; Nogueira, Raul G
2016-08-01
Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. The Field Assessment Stroke Triage for Emergency Destination (FAST-ED) scale was based on items of the National Institutes of Health Stroke Scale (NIHSS) with higher predictive value for LVOS and tested in the Screening Technology and Outcomes Project in Stroke (STOPStroke) cohort, in which patients underwent computed tomographic angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial internal carotid artery, middle cerebral artery-M1, middle cerebral artery-2, or basilar arteries. Patients with partial, bihemispheric, and anterior+posterior circulation occlusions were excluded. Receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value of FAST-ED were compared with the NIHSS, Rapid Arterial Occlusion Evaluation (RACE) scale, and Cincinnati Prehospital Stroke Severity (CPSS) scale. LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the receiver operating characteristic curve: FAST-ED=0.81 as reference; NIHSS=0.80, P=0.28; RACE=0.77, P=0.02; and CPSS=0.75, P=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity of 0.89, positive predictive value of 0.72, and negative predictive value of 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, and 0.79, and CPSS ≥2 of 0.56, 0.85, 0.65, and 0.78, respectively. FAST-ED is a simple scale that if successfully validated in the field, it may be used by medical emergency professionals to identify LVOS in the prehospital setting enabling rapid triage of patients. © 2016 American Heart Association, Inc.
Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M
2010-10-01
There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Anderson, James L.; And Others
1980-01-01
Presents an undergraduate quantitative analysis experiment, describing an atomic absorption quantitation scheme that is fast, sensitive and comparatively simple relative to other titration experiments. (CS)
NASA Technical Reports Server (NTRS)
Ross, H. Richard; Bourgeois, Chris M.
1995-01-01
Apparatus continuously monitors concentration of hydrogen, at level ranging from few parts per million to several percent, in mixture of gases. Simple and fast, providing high sensitivity and linear response. Used to alert technicians to potentially explosive concentrations of residual hydrogen.
Guerrero-Romero, Fernando; Simental-Mendía, Luis E; González-Ortiz, Manuel; Martínez-Abundis, Esperanza; Ramos-Zavala, María G; Hernández-González, Sandra O; Jacques-Camarena, Omar; Rodríguez-Morán, Martha
2010-07-01
To meet the worldwide challenge of emerging diabetes, accessible and inexpensive tests to identify insulin resistance are needed. To evaluate the sensitivity and specificity of the product of fasting, we compared the triglycerides and glucose (TyG) index, a simple measure of insulin resistance, with the euglycemic-hyperinsulinemic clamp test. We conducted a cross-sectional study of the general population and outpatients of the Internal Medicine Department at the Medical Unit of High Specialty of the Specialty Hospital at the West National Medical Center in Guadalajara, Mexico. Eleven nonobese healthy subjects, 34 obese normal glucose tolerance individuals, 22 subjects with prediabetes, and 32 diabetic patients participated in the study. We performed a euglycemic-hyperinsulinemic clamp test. Sensitivity and specificity of the TyG index [Ln(fasting triglycerides) (mg/dl) x fasting glucose (mg/dl)/2] were measured, as well as the area under the curve of the receiver operating characteristic scatter plot and the correlation between the TyG index and the total glucose metabolism (M) rates. Pearson's correlation coefficient between the TyG index and M rates was -0.681 (P < 0.005). Correlation between the TyG index and M rates was similar between men (-0.740) and women (-0.730), nonobese (-0.705) and obese (-0.710), and nondiabetic (-0.670) and diabetic (-0.690) individuals. The best value of the TyG index for diagnosis of insulin resistance was 4.68, which showed the highest sensitivity (96.5%) and specificity (85.0%; area under the curve + 0.858). The TyG index has high sensitivity and specificity, suggesting that it could be useful for identification of subjects with decreased insulin sensitivity.
Muniyappa, Ranganath; Irving, Brian A; Unni, Uma S; Briggs, William M; Nair, K Sreekumaran; Quon, Michael J; Kurpad, Anura V
2010-12-01
Insulin resistance is highly prevalent in Asian Indians and contributes to worldwide public health problems, including diabetes and related disorders. Surrogate measurements of insulin sensitivity/resistance are used frequently to study Asian Indians, but these are not formally validated in this population. In this study, we compared the ability of simple surrogate indices to accurately predict insulin sensitivity as determined by the reference glucose clamp method. In this cross-sectional study of Asian-Indian men (n = 70), we used a calibration model to assess the ability of simple surrogate indices for insulin sensitivity [quantitative insulin sensitivity check index (QUICKI), homeostasis model assessment (HOMA2-IR), fasting insulin-to-glucose ratio (FIGR), and fasting insulin (FI)] to predict an insulin sensitivity index derived from the reference glucose clamp method (SI(Clamp)). Predictive accuracy was assessed by both root mean squared error (RMSE) of prediction as well as leave-one-out cross-validation-type RMSE of prediction (CVPE). QUICKI, FIGR, and FI, but not HOMA2-IR, had modest linear correlations with SI(Clamp) (QUICKI: r = 0.36; FIGR: r = -0.36; FI: r = -0.27; P < 0.05). No significant differences were noted among CVPE or RMSE from any of the surrogate indices when compared with QUICKI. Surrogate measurements of insulin sensitivity/resistance such as QUICKI, FIGR, and FI are easily obtainable in large clinical studies, but these may only be useful as secondary outcome measurements in assessing insulin sensitivity/resistance in clinical studies of Asian Indians.
A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.
Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A
2017-01-15
The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.
Fast ion transport at a gas-metal interface
McDevitt, Christopher J.; Tang, Xian-Zhu; Guo, Zehua
2017-11-06
Fast ion transport and the resulting fusion yield reduction are computed at a gas-metal interface. The extent of fusion yield reduction is observed to depend sensitively on the charge state of the surrounding pusher material and the width of the atomically mixed region. These sensitivities suggest that idealized boundary conditions often implemented at the gas-pusher interface for the purpose of estimating fast ion loss will likely overestimate fusion reactivity reduction in several important limits. Additionally, the impact of a spatially complex material interface is investigated by considering a collection of droplets of the pusher material immersed in a DT plasma.more » It is found that for small Knudsen numbers, the extent of fusion yield reduction scales with the surface area of the material interface. As the Knudsen number is increased, but, the simple surface area scaling is broken, suggesting that hydrodynamic mix has a nontrivial impact on the extent of fast ion losses.« less
Fast and Frugal Framing Effects?
ERIC Educational Resources Information Center
Mccloy, Rachel; Beaman, C. Philip; Frosch, Caren A.; Goddard, Kate
2010-01-01
Using 3 experiments, we examine whether simple pairwise comparison judgments, involving the "recognition heuristic" (Goldstein & Gigerenzer, 2002), are sensitive to implicit cues to the nature of the comparison required. In Experiments 1 and 2, we show that participants frequently choose the recognized option of a pair if asked to make "larger"…
Mohd Nor, Noor Shafina; Lee, SoJung; Bacha, Fida; Tfayli, Hala; Arslanian, Silva
2016-09-01
There is a need for simple surrogate estimates of insulin sensitivity in epidemiological studies of obese youth because the hyperinsulinemic-euglycemic clamp is not feasible on a large scale. (i) To examine the triglyceride glucose (TyG) index (Ln[fasting triglycerides (mg/dL) × fasting glucose (mg/dL)/2]) and its relationship to in vivo insulin sensitivity in obese adolescents (OB) along the spectrum of glucose tolerance and (ii) to compare TyG index with triglyceride/high-density lipoprotein TG/HDL and 1/fasting insulin (1/IF ), other surrogates of insulin sensitivity. Cross-sectional data in 225 OB with normal glucose tolerance (NGT), prediabetes (preDM), and type 2 diabetes (T2DM) who had a 3-h hyperinsulinemic-euglycemic clamp and fasting lipid measurement. Insulin-stimulated glucose disposal (Rd) declined significantly across the glycemic groups from OB-NGT to OB-preDM to OB-T2DM with a corresponding increase in TyG index (8.3 ± 0.5, 8.6 ± 0.5, 8.9 ± 0.6, p < 0.0001). The correlation of TyG index to Rd was -0.419 (p < 0.0001). The optimal TyG index for diagnosis of insulin resistance was 8.52 [receiver operating characteristic-area under the ROC curves (ROC-AUC) 0.750, p < 0.0001]. The ROC-AUC for 1/IF was 0.836. In multiple regression analysis, 64.8% of the variance in Rd was explained by TyG index, 1/IF , body mass index (BMI) z-score, glycemic group, and sex. The TyG index affords an easily and widely available simple laboratory method as a surrogate estimate of insulin sensitivity that could be used repeatedly in large-scale observational and/or interventional cohorts of OB. Although not superior to 1/IF , TyG index offers the advantage of having a standardized method of measuring triglyceride and glucose, which is not the case for insulin assays. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Development of a cyclic voltammetry method for the detection of Clostridium novyi in black disease.
Liu, L L; Jiang, D N; Xiang, G M; Liu, C; Yu, J C; Pu, X Y
2014-03-17
Black disease is an acute disease of sheep and cattle. The pathogen is the obligate anaerobe, Clostridium novyi. Due to difficulties of anaerobic culturing in the country or disaster sites, a simple, rapid, and sensitive method is required. In this study, an electrochemical method, the cyclic voltammetry method, basing on loop-mediated isothermal amplification (LAMP), electrochemical ion bonding (positive dye, methylene blue), was introduced. DNA extracted from C. novyi specimens was amplified through the LAMP reaction. Then the products combined were with methylene blue, which lead to a reduction in the oxidation peak current (ipA) and the reduction peak current (ipC) of the cyclic voltammetry. The changes of ipA/ipC were real-time measured by special designed electrode, so the DNA was quantitatively detected. The results displayed that this electrochemical detection of C. novyi could be completed in 1-2 h with the lowest bacterial concentration of 10(2) colony forming units/mL, and high accuracy (96.5%), sensitivity (96%), and specificity (97%) compared to polymerase chain reation. The cyclic voltammetry method was a simple and fast method, with high sensitivity and high specificity, and has great potential to be a usable molecular tool for fast diagnosis of Black disease.
A fast algorithm for computer aided collimation gamma camera (CACAO)
NASA Astrophysics Data System (ADS)
Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Franck, D.; Pihet, P.; Ballongue, P.
2000-08-01
The computer aided collimation gamma camera is aimed at breaking down the resolution sensitivity trade-off of the conventional parallel hole collimator. It uses larger and longer holes, having an added linear movement at the acquisition sequence. A dedicated algorithm including shift and sum, deconvolution, parabolic filtering and rotation is described. Examples of reconstruction are given. This work shows that a simple and fast algorithm, based on a diagonal dominant approximation of the problem can be derived. Its gives a practical solution to the CACAO reconstruction problem.
Wang, Fangfang; Huang, Lingyun; Na, Na; He, Dacheng; Sun, Dezhi; Ouyang, Jin
2012-05-21
In this paper, a simple and sensitive small-molecule fluorescent probe, 2,5-dihydroxy-4'-dimethylaminochalcone (DHDMAC), was designed and synthesized for the detection of human serum proteins via hydrophobic interactions after polyacrylamide gel electrophoresis (PAGE). This probe produced lower fluorescence emission in the absence of proteins, and the emission intensity was significantly increased after the interaction with serum proteins. To demonstrate the imaging performance of this probe as a fluorescent dye, a series of experiments was conducted that included sensitivity comparison and 2D-PAGE. The results indicated that the sensitivity of DHDMAC staining is comparable to that of the most widely used fluorescent dye, SYPRO Ruby, and more protein spots (including thyroxine-binding globulin, angiotensinogen, afamin, zinc-α-2-glycoprotein and α-1-antichymotrypsin) were detected after 2D-PAGE. Therefore, DHDMAC is a good protein reporter due to its fast staining procedure, low detection limits and high resolution.
Heidbrink, William W.; Ferron, John R.; Holcomb, Christopher T.; ...
2014-08-21
Here, analysis of neutron and fast-ion D α data from the DIII-D tokamak shows that Alfvén eigenmode activity degrades fast-ion confinement in many high β N, high q min, steady-state scenario discharges. (β N is the normalized plasma pressure and q min is the minimum value of the plasma safety factor.) Fast-ion diagnostics that are sensitive to the co-passing population exhibit the largest reduction relative to classical predictions. The increased fast-ion transport in discharges with strong AE activity accounts for the previously observed reduction in global confinement with increasing q min; however, not all high q min discharges show appreciablemore » degradation. Two relatively simple empirical quantities provide convenient monitors of these effects: (1) an 'AE amplitude' signal based on interferometer measurements and (2) the ratio of the neutron rate to a zero-dimensional classical prediction.« less
NASA Astrophysics Data System (ADS)
Hao, Ji-Na; Yan, Bing
2016-01-01
A Eu3+ post-functionalized metal-organic framework of nanosized Ga(OH)bpydc(Eu3+@Ga(OH)bpydc, 1a) with intense luminescence is synthesized and characterized. Luminescence measurements reveal that 1a can detect ammonia gas selectively and sensitively among various indoor air pollutants. 1a can simultaneously determine a biological ammonia metabolite (urinary urea) in the human body, which is a rare example of a luminescent sensor that can monitor pollutants in the environment and also detect their biological markers. Furthermore, 1a exhibits appealing features including high selectivity and sensitivity, fast response, simple and quick regeneration, and excellent recyclability.A Eu3+ post-functionalized metal-organic framework of nanosized Ga(OH)bpydc(Eu3+@Ga(OH)bpydc, 1a) with intense luminescence is synthesized and characterized. Luminescence measurements reveal that 1a can detect ammonia gas selectively and sensitively among various indoor air pollutants. 1a can simultaneously determine a biological ammonia metabolite (urinary urea) in the human body, which is a rare example of a luminescent sensor that can monitor pollutants in the environment and also detect their biological markers. Furthermore, 1a exhibits appealing features including high selectivity and sensitivity, fast response, simple and quick regeneration, and excellent recyclability. Electronic supplementary information (ESI) available: Experimental section; XPS spectra; N2 adsorption-desorption isotherms; ICP data; SEM image; PXRD patterns and other luminescence data. See DOI: 10.1039/c5nr06066d
Li, B; Zhang, Z; Liu, W
2001-05-30
A simple and sensitive flow-injection chemiluminescence (CL) system for automated dissolution testing is described and evaluated for monitoring of dissolution profiles of isoniazid tablets. The undissolved suspended particles in the dissolved solution were eliminated via on-line filter. The novel CL system of KIO(4)-isoniazid was also investigated. The sampling frequency of the system was 120 h(-1). The dissolution profiles of isoniazid fast-release tablets from three sources were determined, which demonstrates the stability, great sensitivity, large dynamic measuring range and robustness of the system.
A Fast, Accurate and Sensitive GC-FID Method for the Analyses of Glycols in Water and Urine
NASA Technical Reports Server (NTRS)
Kuo, C. Mike; Alverson, James T.; Gazda, Daniel B.
2017-01-01
Glycols, specifically ethylene glycol and 1,2-propanediol, are some of the major organic compounds found in the humidity condensate samples collected on the International Space Station. The current analytical method for glycols is a GC/MS method with direct sample injection. This method is simple and fast, but it is not very sensitive. Reporting limits for ethylene glycol and 1,2-propanediol are only 1 ppm. A much more sensitive GC/FID method was developed, in which glycols were derivatized with benzoyl chloride for 10 minutes before being extracted with hexane. Using 1,3-propanediol as an internal standard, the detection limits for the GC/FID method was determined to be 50 ppb and the analysis only takes 7 minutes. Data from the GC/MS and the new GC/FID methods shows excellent agreement with each other. Factors affecting the sensitivity, including sample volume, NaOH concentration and volume, volume of benzoyl chloride, reaction time and temperature, were investigated. Interferences during derivatization and possible method to reduce interferences were also investigated.
Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E
2018-09-01
Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan
2018-04-01
A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.
Xuli, Wu; Weiyi, He; Ji, Kunmei; Wenpu, Wan; Dongsheng, Hu; Hui, Wu; Xinpin, Luo; Zhigang, Liu
2013-03-01
The ingredient declaration on food labels assumes paramount importance in the protection of food-allergic consumers. China has not implemented Food allergen labeling. A gold immunochromatography assay (GICA) was developed using 2 monoclonal antibodies (mAb) against the milk allergen β-lactoglobulin in this study. The GICA was specific for pure milk samples with a sensitivity of 0.2 ng/mL. Milk protein traces extracted from 110 food products were detected by this method. The labels of 106 were confirmed by our GICA method: 57 food samples originally labeled as containing milk were positive for β-lactoglobulin and 49 food samples labeled as not containing milk were negative for β-lactoglobulin. However, 3 food samples falsely labeled as containing milk were found to contain no β-lactoglobulin whereas 1 food sample labeled as not containing milk actually contained β-lactoglobulin. First, these negatives could be because of the addition of a casein fraction. Second, some countries demand that food manufacturers label all ingredients derived from milk as "containing milk" even though the ingredients contain no detectable milk protein by any method. Our GICA method could thus provide a fast and simple method for semiquantitatation of β-lactoglobulin in foods. The present method provides a fast, simple, semiquantitative method for the determination of milk allergens in foods. © 2013 Institute of Food Technologists®
Wide-Field Imaging of Single-Nanoparticle Extinction with Sub-nm2 Sensitivity
NASA Astrophysics Data System (ADS)
Payne, Lukas M.; Langbein, Wolfgang; Borri, Paola
2018-03-01
We report on a highly sensitive wide-field imaging technique for quantitative measurement of the optical extinction cross section σext of single nanoparticles. The technique is simple and high speed, and it enables the simultaneous acquisition of hundreds of nanoparticles for statistical analysis. Using rapid referencing, fast acquisition, and a deconvolution analysis, a shot-noise-limited sensitivity down to 0.4 nm2 is achieved. Measurements on a set of individual gold nanoparticles of 5 nm diameter using this method yield σext=(10.0 ±3.1 ) nm2, which is consistent with theoretical expectations and well above the background fluctuations of 0.9 nm2 .
A Study on the Copper Effect on gold leaching in copper-ethanediamine-thiosulphate solutions
NASA Astrophysics Data System (ADS)
Liu, Qiong; Xiang, Pengzhi; Huang, Yao
2018-01-01
A simple, fast and sensitive square-wave voltammetry (SWV), cyclic voltammetry(CV) and tafel method for the determination of various factors of gold in thiosulphate solution in this paper. We present our study on the effect of copper(II) on the leaching of gold in thiosulphate solutions. The current study aims to establish the interaction of copper in the leaching process by electrochemical method.
Atabek, Mehmet Emre; Pirgon, Ozgur
2007-02-01
Few previous studies have examined the validity of the fasting glucose-to-insulin ratio (FGIR), homeostasis model assessment of insulin resistance (HOMA-IR) and quantitative insulin-sensitivity check index (QUICKI) in pediatric populations. To compare simple indices of insulin resistance calculated from fasting glucose and insulin levels with insulin sensitivity indices (area under the response curve [AUCinsulin], insulin sensitivity index [ISI-compositeL) determined by oral glucose tolerance testing (OGTT) in obese children. One hundred and forty-eight obese children and adolescents (86 girls and 62 boys, mean age: 10.86 +/- 3.08 years, mean body mass index (BMI): 27.7 +/- 4.2) participated in the study. OGTT was performed in all participants. After glucose and insulin measurements from OGTT, the children were divided into two groups according to the presence or absence of insulin resistance. Insulin sensitivity indices obtained from the OGTT were compared between the groups. The total plasma glucose response and insulin secretion were evaluated from the AUC estimated by the trapezoid rule. Cut-off points, and sensitivity and specificity calculations were based on insulin resistance with receiver operating characteristic curve (ROC) analysis. The prevalence of insulin resistance, glucose intolerance and dyslipidemia was 37.1%, 24.3% and 54% in obese children, respectively. The groups consisted of 93 children without insulin resistance (54 girls and 39 boys; mean age: 10.5 +/- 3.3 years; mean BMI: 27.0 +/- 4.2) and 55 children with insulin resistance (32 girls and 23 boys; mean age: 11.4 +/- 2.5 years; mean BMI: 27.9 +/- 3.9). There were significant differences in mean FGIR (10.0 +/- 7.2 vs 5.6 +/- 2.8, p < 0.001), HOMA-IR (3.2 +/- 2.3 vs 4.9 +/- 2.3, p < 0.001) and QUICKI (0.33 +/- 0.03 vs 0.30 +/- 0.02, p < 0.001) between the groups. The cut-off points for diagnosis of insulin resistance were < 5.6 for FGIR (sensitivity 61.8, specificity 76.3), > 2.7 for HOMA-IR (sensitivity 80, specificity 59.1), and < 0.328 for QUICKI (sensitivity 80, specificity 60.2). Indices derived from fasting samples for diagnosis of insulin sensitivity are reliable criteria in obese children and adolescents. HOMA-IR and QUICKI appeared to have similar sensitivity and specificity and to have higher sensitivity than FGIR.
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
2015-01-01
Bacterial meningitis is a serious health concern worldwide. Given that meningitis can be fatal and many meningitis cases occurred in high-poverty areas, a simple, low-cost, highly sensitive method is in great need for immediate and early diagnosis of meningitis. Herein, we report a versatile and cost-effective polydimethylsiloxane (PDMS)/paper hybrid microfluidic device integrated with loop-mediated isothermal amplification (LAMP) for the rapid, sensitive, and instrument-free detection of the main meningitis-causing bacteria, Neisseria meningitidis (N. meningitidis). The introduction of paper into the microfluidic device for LAMP reactions enables stable test results over a much longer period of time than a paper-free microfluidic system. This hybrid system also offers versatile functions, by providing not only on-site qualitative diagnostic analysis (i.e., a yes or no answer), but also confirmatory testing and quantitative analysis in laboratory settings. The limit of detection of N. meningitidis is about 3 copies per LAMP zone within 45 min, close to single-bacterium detection sensitivity. In addition, we have achieved simple pathogenic microorganism detection without a laborious sample preparation process and without the use of centrifuges. This low-cost hybrid microfluidic system provides a simple and highly sensitive approach for fast instrument-free diagnosis of N. meningitidis in resource-limited settings. This versatile PDMS/paper microfluidic platform has great potential for the point of care (POC) diagnosis of a wide range of infectious diseases, especially for developing nations. PMID:25019330
NASA Astrophysics Data System (ADS)
Butler, S. L.
2017-12-01
The electrical resistivity method is now highly developed with 2D and even 3D surveys routinely performed and with available fast inversion software. However, rules of thumb, based on simple mathematical formulas, for important quantities like depth of investigation, horizontal position and resolution have not previously been available and would be useful for survey planning, preliminary interpretation and general education about the method. In this contribution, I will show that the sensitivity function for the resistivity method for a homogeneous half-space can be analyzed in terms of its first and second moments which yield simple mathematical formulas. The first moment gives the sensitivity-weighted center of an apparent resistivity measurement with the vertical center being an estimate of the depth of investigation. I will show that this depth of investigation estimate works at least as well as previous estimates based on the peak and median of the depth sensitivity function which must be calculated numerically for a general four electrode array. The vertical and horizontal first moments can also be used as pseudopositions when plotting 1, 2 and 3D pseudosections. The appropriate horizontal plotting point for a pseudosection was not previously obvious for nonsymmetric arrays. The second moments of the sensitivity function give estimates of the spatial extent of the region contributing to an apparent resistivity measurement and hence are measures of the resolution. These also have simple mathematical formulas.
A simple and efficient HPLC method for benznidazole dosage in human breast milk.
Marson, María E; Padró, Juan M; Reta, Mario R; Altcheh, Jaime; García-Bournissen, Facundo; Mastrantonio, Guido
2013-08-01
Due to migration, Chagas disease is a significant public health problem in Latin America, and in other nonendemic regions. The 2 drugs currently available for the treatment, nifurtimox and benznidazole (BNZ), are associated with a high risk of toxicity in therapeutic doses. Excretion of drug into human breast milk is a potential source of unwanted exposure and pharmacologic effects in the nursing infant. However, this phenomenon was not evaluated until now, and measurement techniques for both drugs in milk were not developed. In this work, we described the development of a simple and fast method to quantify BNZ in human milk using a pretreatment that involves acid protein precipitation followed by tandem microfiltration, and reverse phase high-performance liquid chromatography/ultraviolet analysis. It is simple because it takes only 3 steps to obtain a clean extracted solution that is ready to inject into the high-performance liquid chromatography equipment. It is fast because a complete analysis of a sample takes only 36 minutes. Although the human breast milk composition is very variable, and lipids are one of the most difficult compounds to clean up on a milk sample, the procedure has proven to be robust and sensitive with a limit of detection of 0.3 μg/mL and quantization of 0.9 μg/mL. Despite a 70% recovery value, which could be considered a relatively low result, this recovery is reproducible (coefficient of variation <10%) and the analytical response under the linear range is very good (r = 0.9969 adjusted). Real samples of human breast milk from patients in treatment with BNZ were dosed to support the validation process of the method. The method described is fast, specific, accurate, precise, and sufficiently sensitive in the clinical context for the quantification of BNZ in human milk. For all these reasons, it is suitable for clinical risk evaluation studies.
Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique
2017-04-01
An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi; Pruski, Marek
Two-dimensional through-bond {sup 1}H({sup 13}C) solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse {sup 1}H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of {sup 1}H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N-formyl-l-methionyl-l-leucyl-l-phenylalanine (f-MLF-OH) and brown coal.
NASA Astrophysics Data System (ADS)
Mao, Kanmi; Pruski, Marek
2009-12-01
Two-dimensional through-bond 1H{ 13C} solid-state NMR experiments utilizing fast magic angle spinning (MAS) and homonuclear multipulse 1H decoupling are presented. Remarkable efficiency of polarization transfer can be achieved at MAS rates exceeding 40 kHz, which is instrumental in these measurements. Schemes utilizing direct and indirect detection of heteronuclei are compared in terms of resolution and sensitivity. A simple procedure for optimization of 1H homonuclear decoupling sequences under these conditions is proposed. The capabilities of these techniques were confirmed on two naturally abundant solids, tripeptide N- formyl- L-methionyl- L-leucyl- L-phenylalanine (f-MLF-OH) and brown coal.
Nuzhat, Sharika; Ahmed, Tahmeed; Kawser, Chowdhury Ali; Khan, Azharul Islam; Islam, S M Rafiqul; Shahrin, Lubaba; Shahunja, K M; Shahid, Abu S M S B; Al Imran, Abdullah; Chisti, Mohammod Jobayer
2017-01-01
Children with diarrhea often present with fast breathing due to metabolic acidosis from dehydration. On the other hand, age specific fast breathing is the cornerstone for the diagnosis of pneumonia following classification of pneumonia recommended by the World Health Organization (WHO). Correction of metabolic acidosis by rehydrating the diarrheal children requires time, which delays early initiation of appropriate antimicrobials for pneumonia and thereby increases the risk of deaths. We need to further investigate the simple clinical features other than fast breathing which might help us in earliest diagnosis of pneumonia in children with diarrhea Thus, the objective of our study was to identify other contributing clinical features that may independently help for early diagnosis of pneumonia in diarrheal children who present with age specific fast breathing. This was an unmatched case-control study. Diarrheal children aged 0-59 months, admitted to Dhaka Hospital of the International Centre for Diarrheal Disease Research, Bangladesh (icddr,b) during January 2014 to December 2014 having age specific fast breathing (<2 month ≥60 breath/min, 2-11 months ≥50 breaths/min, >11-59 months ≥40 breaths/min) were studied. The study children with clinical and radiological pneumonia constituted the cases (n = 276) and those without pneumonia constituted the controls (n = 446). Comparison of clinical features and outcomes between the cases and the controls was made. The distribution of acidosis among the cases and the controls was comparable (35% vs. 41%, p = 0.12). The cases had proportionately higher deaths compared to the controls, however, the difference was not statistically significant (3% vs. 1%; p = 0.23). In logistic regression analysis after adjusting for potential confounders, the cases were independently associated with cough (OR = 62.19, 95% CI = 27.79-139.19; p<0.01) and chest wall indrawing (OR = 31.05, 95%CI = 13.43-71.82; p<0.01) and less often had severe acute malnutrition (OR = 0.33, 95%CI = 0.13-0.79; p<0.01). The sensitivity and specificity of cough were 83% (78-87%) and 93% (91-96%). The sensitivity and specificity for lower chest wall indrawing were 65% (59-71%) and 95% (93-97%). However, the sensitivity and specificity of cough and lower chest wall indrawing combined were 94% (89-97%) and 99% (97-100%). Thus, diarrheal children having fast breathing who present with cough and/or lower chest wall indrawing, irrespective of presence or absence of metabolic acidosis, are more likely to have radiological pneumonia. The results underscore the importance of early identification of these simple clinical features that may help to minimize potential delay due to rehydration in initiating prompt treatment of pneumonia in order to reduce fatal consequences in such children.
Bhadoria, Ajeet Singh; Kasar, Pradeep Kumar; Toppo, Neelam Anupama
2015-01-01
Globally the increasing prevalence of diabetes mellitus (DM) is major public health concern. The Indian Diabetes Risk Score (IDRS) was developed by Madras Diabetes Research Foundation (MDRF) as a simple tool to help detect undiagnosed type 2 DM (T2DM) in the community. We conducted a study among 911 adults of Jabalpur District to validate the IDRS score against increased fasting blood sugar levels in diagnosing T2DM. T2DM was confirmed either by history of previously known disease or fasting plasma glucose ≥126 mg/dl on two occasions. Sensitivity, specificity, positive predictive value, negative predictive value, Youden index (sensitivity + specificity -1), likelihood ratio for positive test, and likelihood ratio for negative test were calculated for IDRS cut-offs of ≥20, ≥40, ≥60, and ≥80 against the presence of T2DM (either known diabetic or fasting plasma glucose >126 mg/dl on two occasions). The overall prevalence of T2DM was 9.99% (95% confidence interval, 8.04-11.94%). In the Receiver operating characteristic analysis, IDRS had an area under the curve of 0.736 (P < 0.001). The best cut-off was IDRS 40 with a sensitivity, specificity, and Youden index of 60.4%, 70.7%, and 0.31, respectively. The findings of our study indicate that IDRS has excellent predictive value for detecting undiagnosed diabetes in the community and IDRS is also a much stronger risk indicator than examining individual risk factors like age, family history, obesity, or physical activity.
Highly sensitive and selective liquid crystal optical sensor for detection of ammonia.
Niu, Xiaofang; Zhong, Yuanbo; Chen, Rui; Wang, Fei; Luo, Dan
2017-06-12
Ammonia detection technologies are very important in environment monitoring. However, most existing technologies are complex and expensive, which limit the useful range of real-time application. Here, we propose a highly sensitive and selective optical sensor for detection of ammonia (NH 3 ) based on liquid crystals (LCs). This optical sensor is realized through the competitive binding between ammonia and liquid crystals on chitosan-Cu 2+ that decorated on glass substrate. We achieve a broad detection range of ammonia from 50 ppm to 1250 ppm, with a low detection limit of 16.6 ppm. This sensor is low-cost, simple, fast, and highly sensitive and selective for detection of ammonia. The proposal LC sensing method can be a sensitive detection platform for other molecule monitors such as proteins, DNAs and other heavy metal ions by modifying sensing molecules.
Shelley, Jacob T; Hieftje, Gary M
2010-04-01
The recent development of ambient desorption/ionization mass spectrometry (ADI-MS) has enabled fast, simple analysis of many different sample types. The ADI-MS sources have numerous advantages, including little or no required sample pre-treatment, simple mass spectra, and direct analysis of solids and liquids. However, problems of competitive ionization and limited fragmentation require sample-constituent separation, high mass accuracy, and/or tandem mass spectrometry (MS/MS) to detect, identify, and quantify unknown analytes. To maintain the inherent high throughput of ADI-MS, it is essential for the ion source/mass analyzer combination to measure fast transient signals and provide structural information. In the current study, the flowing atmospheric-pressure afterglow (FAPA) ionization source is coupled with a time-of-flight mass spectrometer (TOF-MS) to analyze fast transient signals (<500 ms FWHM). It was found that gas chromatography (GC) coupled with the FAPA source resulted in a reproducible (<5% RSD) and sensitive (detection limits of <6 fmol for a mixture of herbicides) system with analysis times of ca. 5 min. Introducing analytes to the FAPA in a transient was also shown to significantly reduce matrix effects caused by competitive ionization by minimizing the number and amount of constituents introduced into the ionization source. Additionally, MS/MS with FAPA-TOF-MS, enabling analyte identification, was performed via first-stage collision-induced dissociation (CID). Lastly, molecular and structural information was obtained across a fast transient peak by modulating the conditions that caused the first-stage CID.
Fetal acoustic stimulation test for early intrapartum fetal monitoring.
Goonewardene, M; Hanwellage, K
2011-03-01
The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p < 0.001), specificity (100% vs 87%, p = 0.017), positive predictive value (100% vs 98%, p = 0.024), negative predictive value (79% vs 17%, p < 0.001) and accuracy (99%vs 64%, p < 0.001) in predicting 5 minute APGAR < 7 in the baby. FAST is a reliable screening test for assessing fetal well being in early labour. It complements the NST and is better than the NST alone.
Spectroscopic vector analysis for fast pattern quality monitoring
NASA Astrophysics Data System (ADS)
Sohn, Younghoon; Ryu, Sungyoon; Lee, Chihoon; Yang, Yusin
2018-03-01
In semiconductor industry, fast and effective measurement of pattern variation has been key challenge for assuring massproduct quality. Pattern measurement techniques such as conventional CD-SEMs or Optical CDs have been extensively used, but these techniques are increasingly limited in terms of measurement throughput and time spent in modeling. In this paper we propose time effective pattern monitoring method through the direct spectrum-based approach. In this technique, a wavelength band sensitive to a specific pattern change is selected from spectroscopic ellipsometry signal scattered by pattern to be measured, and the amplitude and phase variation in the wavelength band are analyzed as a measurement index of the pattern change. This pattern change measurement technique is applied to several process steps and verified its applicability. Due to its fast and simple analysis, the methods can be adapted to the massive process variation monitoring maximizing measurement throughput.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram
Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.
Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram; ...
2017-11-07
Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.
Wang, J; Ashley, K; Marlow, D; England, E C; Carlton, G
1999-03-01
A simple, fast, sensitive, and economical field method was developed and evaluated for the determination of hexavalent chromium (CrVI) in environmental and workplace air samples. By means of ultrasonic extraction in combination with a strong anion-exchange solid-phase extraction (SAE-SPE) technique, the filtration, isolation, and determination of CrVI in the presence of trivalent chromium (CrIII) and potential interferents was achieved. The method entails (1) ultrasonication in basic ammonium buffer solution to extract CrVI from environmental matrixes; (2) SAE-SPE to separate CrVI from CrIII and interferences; (3) elution/acidification of the eluate; (4) complexation of chromium with 1,5-diphenylcarbazide; and (5) spectrophotometric determination of the colored chromium-diphenylcarbazone complex. Several critical parameters were optimized in order to effect the extraction of both soluble (K2CrO4) and insoluble (PbCrO4) forms of CrVI without inducing CrIII oxidation or CrVI reduction. The method allowed for the dissolution and purification of CrVI from environmental and workplace air sample matrixes for up to 24 samples simultaneously in less than 90 min (including ultrasonication). The results demonstrated that the method was simple, fast, quantitative, and sufficiently sensitive for the determination of occupational exposures of CrVI. The method is applicable for on-site monitoring of CrVI in environmental and industrial hygiene samples.
NASA Astrophysics Data System (ADS)
Shen, Yalong; Yu, Dejian; Wang, Xiong; Huo, Chengxue; Wu, Ye; Zhu, Zhengfeng; Zeng, Haibo
2018-02-01
Inorganic halide perovskites exhibited promising potentials for high-performance wide-band photodetectors (PDs) due to their high light absorption coefficients, long carrier diffusion length and wide light absorption ranges. Here, we report two-dimensional (2D) CsPbBr3/PCBM heterojunctions for sensitive, fast and flexible PDs, whose performances can be greatly boosted by the charge transfer through the energy-aligned interface. The 2D CsPbBr3 nanosheets with high crystallinity were fabricated via a simple solution-process at room temperature, and then assembled into flexible heterojunctions films with polymerphenyl-C61-butyric acid methyl ester (PCBM). Significantly, the efficient and fast charge transfer at the heterojunctions interface was evidenced by the obvious photoluminescence quenching and variation of recombination dynamics. Subsequently, such heterojunctions PD exhibited an enhanced responsivity of 10.85 A W-1 and an ultrahigh detectivity of 3.06 × 1013 Jones. In addition, the PD shows a broad linear dynamic range of 73 dB, a fast response speed with rise time of 44 μs and decay time of 390 μs, respectively. Moreover, the PD lying on polyethylene terephthalate substrates exhibited an outstanding mechanical flexibility and a robust electrical stability. These results could provide a new avenue for integration of 2D perovskites and organic functional materials and for high-performance flexible PDs.
NASA Astrophysics Data System (ADS)
Wang, Huarui; Shen, Jianqi
2014-05-01
The size of nanoparticles is measured by laser diode self-mixing interferometry, which employs a sensitive, compact, and simple optical setup. However, the signal processing of the interferometry is slow or expensive. In this article, a fast and economic signal processing technique is introduced, in which the self-mixing AC signal is transformed into DC signals with an analog circuit consisting of 16 channels. These DC signals are obtained as a spectrum from which the size of nanoparticles can be retrieved. The technique is examined by measuring the standard nanoparticles. Further experiments are performed to compare the skimmed milk and whole milk, and also the fresh skimmed milk and rotten skimmed milk.
Rao, Ameya; Long, Hu; Harley-Trochimczyk, Anna; Pham, Thang; Zettl, Alex; Carraro, Carlo; Maboudian, Roya
2017-01-25
A simple and versatile strategy is presented for the localized on-chip synthesis of an ordered metal oxide hollow sphere array directly on a low power microheater platform to form a closely integrated miniaturized gas sensor. Selective microheater surface modification through fluorinated monolayer self-assembly and its subsequent microheater-induced thermal decomposition enables the position-controlled deposition of an ordered two-dimensional colloidal sphere array, which serves as a sacrificial template for metal oxide growth via homogeneous chemical precipitation; this strategy ensures control in both the morphology and placement of the sensing material on only the active heated area of the microheater platform, providing a major advantage over other methods of presynthesized nanomaterial integration via suspension coating or printing. A fabricated tin oxide hollow sphere-based sensor shows high sensitivity (6.5 ppb detection limit) and selectivity toward formaldehyde, and extremely fast response (1.8 s) and recovery (5.4 s) times. This flexible and scalable method can be used to fabricate high performance miniaturized gas sensors with a variety of hollow nanostructured metal oxides for a range of applications, including combining multiple metal oxides for superior sensitivity and tunable selectivity.
Aknoun, Sherazade; Savatier, Julien; Bon, Pierre; Galland, Frédéric; Abdeladim, Lamiae; Wattellier, Benoit; Monneret, Serge
2015-01-01
Single-cell dry mass measurement is used in biology to follow cell cycle, to address effects of drugs, or to investigate cell metabolism. Quantitative phase imaging technique with quadriwave lateral shearing interferometry (QWLSI) allows measuring cell dry mass. The technique is very simple to set up, as it is integrated in a camera-like instrument. It simply plugs onto a standard microscope and uses a white light illumination source. Its working principle is first explained, from image acquisition to automated segmentation algorithm and dry mass quantification. Metrology of the whole process, including its sensitivity, repeatability, reliability, sources of error, over different kinds of samples and under different experimental conditions, is developed. We show that there is no influence of magnification or spatial light coherence on dry mass measurement; effect of defocus is more critical but can be calibrated. As a consequence, QWLSI is a well-suited technique for fast, simple, and reliable cell dry mass study, especially for live cells.
Modeling rate sensitivity of exercise transient responses to limb motion.
Yamashiro, Stanley M; Kato, Takahide
2014-10-01
Transient responses of ventilation (V̇e) to limb motion can exhibit predictive characteristics. In response to a change in limb motion, a rapid change in V̇e is commonly observed with characteristics different than during a change in workload. This rapid change has been attributed to a feed-forward or adaptive response. Rate sensitivity was explored as a specific hypothesis to explain predictive V̇e responses to limb motion. A simple model assuming an additive feed-forward summation of V̇e proportional to the rate of change of limb motion was studied. This model was able to successfully account for the adaptive phase correction observed during human sinusoidal changes in limb motion. Adaptation of rate sensitivity might also explain the reduction of the fast component of V̇e responses previously reported following sudden exercise termination. Adaptation of the fast component of V̇e response could occur by reduction of rate sensitivity. Rate sensitivity of limb motion was predicted by the model to reduce the phase delay between limb motion and V̇e response without changing the steady-state response to exercise load. In this way, V̇e can respond more quickly to an exercise change without interfering with overall feedback control. The asymmetry between responses to an incremental and decremental ramp change in exercise can also be accounted for by the proposed model. Rate sensitivity leads to predicted behavior, which resembles responses observed in exercise tied to expiratory reserve volume. Copyright © 2014 the American Physiological Society.
Sutariya, Pinkesh G; Pandya, Alok; Lodha, Anand; Menon, Shobhana K
2016-01-15
A new, simple, ultra-sensitive and selective approach has been reported for the "on spot" colorimetric detection of creatinine based on calix[4]arene functionalized gold nanoparticles (AuNPs) with excellent discrimination in the presence of other biomolecules. The lower detection limit of the method is 2.16nM. The gold nanoparticles and p-tert-butylcalix[4]arene were synthesized by microwave assisted method. Specifically, in our study, we used dynamic light scattering (DLS) which is a powerful method for the determination of small changes in particle size, improved selectivity and sensitivity of the creatinine detection system over colorimetric method. The nanoassembly is characterized by Transmission electron microscopy (TEM), DLS, UV-vis and ESI-MS spectroscopy, which demonstrates the binding affinity due its ability of hydrogen bonding and electrostatic interaction between -NH group of creatinine and pSDSC4. It exhibits fast response time (<60s) to creatinine and has long shelf-life (>5 weeks). The developed pSDSC4-AuNPs based creatinine biosensor will be established as simple, reliable and accurate tool for the determination of creatinine in human urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.
DNA Electrochemistry and Electrochemical Sensors for Nucleic Acids.
Ferapontova, Elena E
2018-06-12
Sensitive, specific, and fast analysis of nucleic acids (NAs) is strongly needed in medicine, environmental science, biodefence, and agriculture for the study of bacterial contamination of food and beverages and genetically modified organisms. Electrochemistry offers accurate, simple, inexpensive, and robust tools for the development of such analytical platforms that can successfully compete with other approaches for NA detection. Here, electrode reactions of DNA, basic principles of electrochemical NA analysis, and their relevance for practical applications are reviewed and critically discussed.
NASA Astrophysics Data System (ADS)
Shen, Youming; Zhang, Xiangyang; Zhang, Chunxiang; Zhang, Youyu; Jin, Junling; Li, Haitao
2018-02-01
A simple benzothiazole fluorescent chemosensor was developed for the fast sequential detection of Cu2 + and biothiols through modulating the excited-state intramolecular proton transfer (ESIPT) process. The compound 1 exhibits highly selective and sensitive fluorescence ;on-off; recognition to Cu2 + with a 1:1 binding stoichiometry by ESIPT hinder. The in situ generated 1-Cu2 + complex can serve as an ;on-off; fluorescent probe for high selectivity toward biothiols via Cu2 + displacement approach, which exerts ESIPT recovery. It is worth pointing out that the 1-Cu2 + complex shows faster for cysteins (within 1 min) than other biothiols such as homocysteine (25 min) and glutathione (25 min). Moreover, the compound 1 displays 160 nm Stoke-shift for reversibly monitoring Cu2 + and biothiols. In addition, the probe is successfully used for fluorescent cellular imaging. This strategy via modulation the ESIPT state has been used for determination of Cu2 + and Cys with satisfactory results, which further demonstrates its value of practical applications.
NASA Astrophysics Data System (ADS)
Meddings, Nina; Owen, John R.; Garcia-Araez, Nuria
2017-10-01
Lithium ion conducting membranes are important to protect the lithium metal electrode and act as a barrier to crossover species such as polysulphides in Li-S systems, redox mediators in Li-O2 cells or dissolved cathode species or electrolyte oxidation products in high voltage Li-ion batteries. We present an in-situ method for measuring permeability of membranes to crossover redox species. The method employs a 'Swagelok' cell design equipped with a glassy carbon working electrode, in which redox species are placed initially in the counter electrode compartment only. Permeability through the membrane, which separates working and counter electrodes, is determined using a square wave voltammetry technique that allows the concentration of crossover redox species to be evaluated over time with very high precision. We test the method using a model and well-behaved electrochemical system to demonstrate its sensitivity, reproducibility and reliability relative to alternative approaches. This new method offers advantages in terms of small electrolyte volume, and simple, fast, quantitative and in-situ measurement.
Hao, Ji-Na; Yan, Bing
2016-02-07
A Eu(3+) post-functionalized metal-organic framework of nanosized Ga(OH)bpydc(Eu(3+)@Ga(OH)bpydc, 1a) with intense luminescence is synthesized and characterized. Luminescence measurements reveal that 1a can detect ammonia gas selectively and sensitively among various indoor air pollutants. 1a can simultaneously determine a biological ammonia metabolite (urinary urea) in the human body, which is a rare example of a luminescent sensor that can monitor pollutants in the environment and also detect their biological markers. Furthermore, 1a exhibits appealing features including high selectivity and sensitivity, fast response, simple and quick regeneration, and excellent recyclability.
Humidity-Responsive Gold Aerogel for Real-Time Monitoring of Human Breath.
Ali, Israt; Chen, Liming; Huang, Youju; Song, Liping; Lu, Xuefei; Liu, Baoqing; Zhang, Lei; Zhang, Jiawei; Hou, Linxi; Chen, Tao
2018-04-24
Humidity sensors have received considerable attention in recent years because of their significance and wide applications in agriculture, industries, goods stores, and medical fields. However, the conventional humidity sensors usually possessed a complex sensing mechanism and low sensitivity and required a time-consuming, labor-intensive process. The exploration for an ideal sensing material to amplify the sensitivity of humidity sensors is still a big challenge. Herein, we developed a simple, low-cost, and scalable fabrication strategy to construct a highly sensitive humidity sensor based on polymer/gold nanoparticle (AuNP) hybrid materials. The hybrid polymer/AuNP aerogel was prepared by a simple freeze-drying method. By taking advantage of the conductivity of AuNPs and high surface area of the highly porous structure, the hybrid poly- N-isopropylacrylamide (PNIPAm)/AuNP aerogel showed high sensitivity to water molecules. Interestingly, the hybrid PNIPAm/AuNP aerogel-based humidity sensor can be used to detect human breath in different states, such as normal breath, fast breath, and deep breath, or in different individuals such as persons with illness, persons who are smoking, and persons who are normal, which is promising in practical flexible wearable devices for human health monitoring. In addition, the humidity sensor can be used in whistle tune recognition.
Lee, Ho-Won; Muniyappa, Ranganath; Yan, Xu; Yue, Lilly Q.; Linden, Ellen H.; Chen, Hui; Hansen, Barbara C.
2011-01-01
The euglycemic glucose clamp is the reference method for assessing insulin sensitivity in humans and animals. However, clamps are ill-suited for large studies because of extensive requirements for cost, time, labor, and technical expertise. Simple surrogate indexes of insulin sensitivity/resistance including quantitative insulin-sensitivity check index (QUICKI) and homeostasis model assessment (HOMA) have been developed and validated in humans. However, validation studies of QUICKI and HOMA in both rats and mice suggest that differences in metabolic physiology between rodents and humans limit their value in rodents. Rhesus monkeys are a species more similar to humans than rodents. Therefore, in the present study, we evaluated data from 199 glucose clamp studies obtained from a large cohort of 86 monkeys with a broad range of insulin sensitivity. Data were used to evaluate simple surrogate indexes of insulin sensitivity/resistance (QUICKI, HOMA, Log HOMA, 1/HOMA, and 1/Fasting insulin) with respect to linear regression, predictive accuracy using a calibration model, and diagnostic performance using receiver operating characteristic. Most surrogates had modest linear correlations with SIClamp (r ≈ 0.4–0.64) with comparable correlation coefficients. Predictive accuracy determined by calibration model analysis demonstrated better predictive accuracy of QUICKI than HOMA and Log HOMA. Receiver operating characteristic analysis showed equivalent sensitivity and specificity of most surrogate indexes to detect insulin resistance. Thus, unlike in rodents but similar to humans, surrogate indexes of insulin sensitivity/resistance including QUICKI and log HOMA may be reasonable to use in large studies of rhesus monkeys where it may be impractical to conduct glucose clamp studies. PMID:21209021
Factors That Influence Fast Mapping in Children Exposed to Spanish and English
Alt, Mary; Meyers, Christina; Figueroa, Cecilia
2015-01-01
Purpose The purpose of this study was to determine if children exposed to two languages would benefit from the phonotactic probability cues of a single language in the same way as monolingual peers and to determine if cross-linguistic influence would be present in a fast mapping task. Method Two groups of typically-developing children (monolingual English and bilingual Spanish-English) took part in a computer-based fast mapping task which manipulated phonotactic probability. Children were preschool-aged (N = 50) or school-aged (N = 34). Fast mapping was assessed through name identification and naming tasks. Data were analyzed using mixed ANOVAs with post-hoc testing and simple regression. Results Bilingual and monolingual preschoolers showed sensitivity to English phonotactic cues in both tasks, but bilingual preschoolers were less accurate than monolingual peers in the naming task. School-aged bilingual children had nearly identical performance to monolingual peers. Conclusions Knowing that children exposed to two languages can benefit from the statistical cues of a single language can help inform ideas about instruction and assessment for bilingual learners. PMID:23816663
Yu, Xiuxia; He, Yi; Jiang, Jie; Cui, Hua
2014-02-17
Chloramphenicol (CHL) as a broad-spectrum antibiotic has a broad action spectrum against Gram-positive and Gram-negative bacteria, as well as anaerobes. The use of CHL is strictly restricted in poultry because of its toxic effect. However, CHL is still illegally used in animal farming because of its accessibility and low cost. Therefore, sensitive methods are highly desired for the determination of CHL in foodstuffs. The immunoassays based on labeling as an important tool have been reported for the detection of CHL residues in food-producing animals. However, most of the labeling procedures require multi-step reactions and purifications and thus they are complicated and time-consuming. Recently, in our previous work, luminol functionalized silver nanoparticles have been successfully synthesized, which exhibits higher CL efficiency than luminol functionalized gold nanoparticles. In this work, the new luminol functionalized silver nanoparticles have been used for the labeling of small molecules CHL for the first time and a competitive chemiluminescent immunoassay has been developed for the detection of CHL. Owing to the amplification of silver nanoparticles, high sensitivity for CHL could be achieved with a low detection limit of 7.6×10(-9) g mL(-1) and a wide linear dynamic range of 1.0×10(-8)-1.0×10(-6) g mL(-1). This method has also been successfully applied to determine CHL in milk and honey samples with a good recoveries (92% and 102%, 99% and 107% respectively), indicating that the method is feasible for the determination of CHL in real milk and honey samples. The labeling procedure is simple, convenient and fast, superior to previously reported labeling procedures. The immunoassay is also simple, fast, sensitive and selective. It is of application potential for the determination of CHL in foodstuffs. Copyright © 2014 Elsevier B.V. All rights reserved.
Non-destructive fraud detection in rosehip oil by MIR spectroscopy and chemometrics.
Santana, Felipe Bachion de; Gontijo, Lucas Caixeta; Mitsutake, Hery; Mazivila, Sarmento Júnior; Souza, Leticia Maria de; Borges Neto, Waldomiro
2016-10-15
Rosehip oil (Rosa eglanteria L.) is an important oil in the food, pharmaceutical and cosmetic industries. However, due to its high added value, it is liable to adulteration with other cheaper or lower quality oils. With this perspective, this work provides a new simple, fast and accurate methodology using mid-infrared (MIR) spectroscopy and partial least squares discriminant analysis (PLS-DA) as a means to discriminate authentic rosehip oil from adulterated rosehip oil containing soybean, corn and sunflower oils in different proportions. The model showed excellent sensitivity and specificity with 100% correct classification. Therefore, the developed methodology is a viable alternative for use in the laboratory and industry for standard quality analysis of rosehip oil since it is fast, accurate and non-destructive. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sun, Ruiling; Wang, Yong; Ni, Yongnian; Kokot, Serge
2014-03-01
A simple, inexpensive and sensitive kinetic spectrophotometric method was developed for the simultaneous determination of three anti-carcinogenic flavonoids: catechin, quercetin and naringenin, in fruit samples. A yellow chelate product was produced in the presence neocuproine and Cu(I) - a reduction product of the reaction between the flavonoids with Cu(II), and this enabled the quantitative measurements with UV-vis spectrophotometry. The overlapping spectra obtained, were resolved with chemometrics calibration models, and the best performing method was the fast independent component analysis (fast-ICA/PCR (Principal component regression)); the limits of detection were 0.075, 0.057 and 0.063 mg L-1 for catechin, quercetin and naringenin, respectively. The novel method was found to outperform significantly the common HPLC procedure.
Efficient estimators for likelihood ratio sensitivity indices of complex stochastic dynamics.
Arampatzis, Georgios; Katsoulakis, Markos A; Rey-Bellet, Luc
2016-03-14
We demonstrate that centered likelihood ratio estimators for the sensitivity indices of complex stochastic dynamics are highly efficient with low, constant in time variance and consequently they are suitable for sensitivity analysis in long-time and steady-state regimes. These estimators rely on a new covariance formulation of the likelihood ratio that includes as a submatrix a Fisher information matrix for stochastic dynamics and can also be used for fast screening of insensitive parameters and parameter combinations. The proposed methods are applicable to broad classes of stochastic dynamics such as chemical reaction networks, Langevin-type equations and stochastic models in finance, including systems with a high dimensional parameter space and/or disparate decorrelation times between different observables. Furthermore, they are simple to implement as a standard observable in any existing simulation algorithm without additional modifications.
Efficient estimators for likelihood ratio sensitivity indices of complex stochastic dynamics
NASA Astrophysics Data System (ADS)
Arampatzis, Georgios; Katsoulakis, Markos A.; Rey-Bellet, Luc
2016-03-01
We demonstrate that centered likelihood ratio estimators for the sensitivity indices of complex stochastic dynamics are highly efficient with low, constant in time variance and consequently they are suitable for sensitivity analysis in long-time and steady-state regimes. These estimators rely on a new covariance formulation of the likelihood ratio that includes as a submatrix a Fisher information matrix for stochastic dynamics and can also be used for fast screening of insensitive parameters and parameter combinations. The proposed methods are applicable to broad classes of stochastic dynamics such as chemical reaction networks, Langevin-type equations and stochastic models in finance, including systems with a high dimensional parameter space and/or disparate decorrelation times between different observables. Furthermore, they are simple to implement as a standard observable in any existing simulation algorithm without additional modifications.
Efficient estimators for likelihood ratio sensitivity indices of complex stochastic dynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arampatzis, Georgios; Katsoulakis, Markos A.; Rey-Bellet, Luc
2016-03-14
We demonstrate that centered likelihood ratio estimators for the sensitivity indices of complex stochastic dynamics are highly efficient with low, constant in time variance and consequently they are suitable for sensitivity analysis in long-time and steady-state regimes. These estimators rely on a new covariance formulation of the likelihood ratio that includes as a submatrix a Fisher information matrix for stochastic dynamics and can also be used for fast screening of insensitive parameters and parameter combinations. The proposed methods are applicable to broad classes of stochastic dynamics such as chemical reaction networks, Langevin-type equations and stochastic models in finance, including systemsmore » with a high dimensional parameter space and/or disparate decorrelation times between different observables. Furthermore, they are simple to implement as a standard observable in any existing simulation algorithm without additional modifications.« less
Yun, Myeong Gu; Kim, Ye Kyun; Ahn, Cheol Hyoun; Cho, Sung Woon; Kang, Won Jun; Cho, Hyung Koun; Kim, Yong-Hoon
2016-01-01
We have demonstrated that photo-thin film transistors (photo-TFTs) fabricated via a simple defect-generating process could achieve fast recovery, a high signal to noise (S/N) ratio, and high sensitivity. The photo-TFTs are inverted-staggered bottom-gate type indium-gallium-zinc-oxide (IGZO) TFTs fabricated using atomic layer deposition (ALD)-derived Al2O3 gate insulators. The surfaces of the Al2O3 gate insulators are damaged by ion bombardment during the deposition of the IGZO channel layers by sputtering and the damage results in the hysteresis behavior of the photo-TFTs. The hysteresis loops broaden as the deposition power density increases. This implies that we can easily control the amount of the interface trap sites and/or trap sites in the gate insulator near the interface. The photo-TFTs with large hysteresis-related defects have high S/N ratio and fast recovery in spite of the low operation voltages including a drain voltage of 1 V, positive gate bias pulse voltage of 3 V, and gate voltage pulse width of 3 V (0 to 3 V). In addition, through the hysteresis-related defect-generating process, we have achieved a high responsivity since the bulk defects that can be photo-excited and eject electrons also increase with increasing deposition power density. PMID:27553518
Pradhan, A S; Quast, U; Sharma, P K
1994-09-01
A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted radiation increases with the energy of the electron beams. Consequently, the ratio of readouts of TLDS held on the two sides of a lead plate varied sharply (by factor of 70) with a change in energy of the electron beam from 5 MeV to 18 MeV, offering a very sensitive method for the measurement of the energy of electron beams. By using the ratio of TL readouts of two types of TLD ribbon with widely different sensitivities, LiF TLD-700 ribbons on the upstream side and highly sensitive CaF2:Dy TLD-200 ribbons on the downstream side, an electron energy discrimination of better than +/- 0.1 MeV could be achieved. The homogeneity of the electron beam energy and the absorbed dose was measured by using a jig in which the TLDS were held in the desired array on both sides of a 4 mm thick lead plate. The method takes minimal beam time and makes it possible to carry out measurements for the audit of the quality of electron beams as well as for intercomparison of beams by mail.
Characterization of PLD grown WO3 thin films for gas sensing
NASA Astrophysics Data System (ADS)
Boyadjiev, Stefan I.; Georgieva, Velichka; Stefan, Nicolaie; Stan, George E.; Mihailescu, Natalia; Visan, Anita; Mihailescu, Ion N.; Besleaga, Cristina; Szilágyi, Imre M.
2017-09-01
Tungsten trioxide (WO3) thin films were grown by pulsed laser deposition (PLD) with the aim to be applied in gas sensors. The films were studied by atomic force microscopy (AFM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy and profilometry. To study the gas sensing behavior of these WO3 films, they were deposited on quartz resonators and the quartz crystal microbalance (QCM) method was applied to analyze their gas sensitivity. Synthesis of tetragonal-WO3 films starting from a target with predominantly monoclinic WO3 phase was observed. The films deposited at 300 °C presented a surface topology favorable for the sorption properties, consisting of a film matrix with protruding craters/cavities. QCM prototype sensors with such films were tested for NO2 sensing. The PLD grown WO3 thin films show good sensitivity and fast reaction at room temperature, even in as-deposited state. With the presented technology, the manufacturing of QCM gas sensors is simple, fast and cost-effective, and it is also suitable for energy-effective portable equipment for on-line monitoring of environmental changes.
He, Zhongfu; Chen, Wenjun; Liang, Binghao; Liu, Changyong; Yang, Leilei; Lu, Dongwei; Mo, Zichao; Zhu, Hai; Tang, Zikang; Gui, Xuchun
2018-04-18
Flexible pressure sensors are of great importance to be applied in artificial intelligence and wearable electronics. However, assembling a simple structure, high-performance capacitive pressure sensor, especially for monitoring the flow of liquids, is still a big challenge. Here, on the basis of a sandwich-like structure, we propose a facile capacitive pressure sensor optimized by a flexible, low-cost nylon netting, showing many merits including a high response sensitivity (0.33 kPa -1 ) in a low-pressure regime (<1 kPa), an ultralow detection limit as 3.3 Pa, excellent working stability after more than 1000 cycles, and synchronous monitoring for human pulses and clicks. More important, this sensor exhibits an ultrafast response speed (<20 ms), which enables its detection for the fast variations of a small applied pressure from the morphological changing processes of a droplet falling onto the sensor. Furthermore, a capacitive pressure sensor array is fabricated for demonstrating the ability to spatial pressure distribution. Our developed pressure sensors show great prospects in practical applications such as health monitoring, flexible tactile devices, and motion detection.
2010-01-01
Background Citrus Bacterial Canker (CBC) is a major, highly contagious disease of citrus plants present in many countries in Asia, Africa and America, but not in the Mediterranean area. There are three types of Citrus Bacterial Canker, named A, B, and C that have different genotypes and posses variation in host range within citrus species. The causative agent for type A CBC is Xanthomonas citri subsp. citri, while Xanthomonas fuscans subsp. aurantifolii, strain B causes type B CBC and Xanthomonas fuscans subsp. aurantifolii strain C causes CBC type C. The early and accurate identification of those bacteria is essential for the protection of the citrus industry. Detection methods based on bacterial isolation, antibodies or polymerase chain reaction (PCR) have been developed previously; however, these approaches may be time consuming, laborious and, in the case of PCR, it requires expensive laboratory equipment. Loop-mediated isothermal amplification (LAMP), which is a novel isothermal DNA amplification technique, is sensitive, specific, fast and requires no specialized laboratory equipment. Results A loop-mediated isothermal amplification assay for the diagnosis of Citrus Bacterial Canker (CBC-LAMP) was developed and evaluated. DNA samples were obtained from infected plants or cultured bacteria. A typical ladder-like pattern on gel electrophoresis was observed in all positive samples in contrast to the negative controls. In addition, amplification products were detected by visual inspection using SYBRGreen and using a lateral flow dipstick, eliminating the need for gel electrophoresis. The sensitivity and specificity of the assay were evaluated in different conditions and using several sample sources which included purified DNA, bacterium culture and infected plant tissue. The sensitivity of the CBC-LAMP was 10 fg of pure Xcc DNA, 5 CFU in culture samples and 18 CFU in samples of infected plant tissue. No cross reaction was observed with DNA of other phytopathogenic bacteria. The assay was capable of detecting CBC-causing strains from several geographical origins and pathotypes. Conclusions The CBC-LAMP technique is a simple, fast, sensitive and specific method for the diagnosis of Citrus Bacterial Canker. This method can be useful in the phytosanitary programs of the citrus industry worldwide. PMID:20565886
NASA Astrophysics Data System (ADS)
Kim, Jong H.
2018-03-01
In this work, an efficient colorimetric chemosensor for the detection of ethylamines using a pyridinium salt (the Zincke salt) is reported. Highly sensitive and selective reactivity of the Zincke salt enables colorimetric response of the Zincke salt solution to the ethylamines by showing well-defined visible color changes from colorless to the deep red. Furthermore, the Zincke salt thin film exhibits discernable color changes in response to ethylamine gas as well, which allows fabrication of simple, fast and portable strip- and textile-type ethylamine sensors.
Magnetically engineered smart thin films: toward lab-on-chip ultra-sensitive molecular imaging.
Hassan, Muhammad A; Saqib, Mudassara; Shaikh, Haseeb; Ahmad, Nasir M; Elaissari, Abdelhamid
2013-03-01
Magnetically responsive engineered smart thin films of nanoferrites as contrast agent are employed to develop surface based magnetic resonance imaging to acquire simple yet fast molecular imaging. The work presented here can be of significant potential for future lab-on-chip point-of-care diagnostics from the whole blood pool on almost any substrates to reduce or even prevent clinical studies involve a living organism to enhance the non-invasive imaging to advance the '3Rs' of work in animals-replacement, refinement and reduction.
The determination of antipyrine elimination in saliva by liquid chromatography.
Gartzke, J; Jäger, H
1991-01-01
A simple, fast and reliable liquid chromatographic method for the determination of antipyrine in saliva is described. The elimination of antipyrine is a good indicator for general evaluation of the liver function for dispositional purposes for example in occupational and environmental medicine. The described LC method was compared with a more extensive photometric procedure. The results obtained from both methods show very good correlation. Only one measurement is necessary to determine the antipyrine clearance. Furthermore the antipyrine dosage can be minimized, because of the sensitivity of the HPLC-method.
Terahertz imaging through self-mixing in a quantum cascade laser.
Dean, Paul; Lim, Yah Leng; Valavanis, Alex; Kliese, Russell; Nikolić, Milan; Khanna, Suraj P; Lachab, Mohammad; Indjin, Dragan; Ikonić, Zoran; Harrison, Paul; Rakić, Aleksandar D; Linfield, Edmund H; Davies, A Giles
2011-07-01
We demonstrate terahertz (THz) frequency imaging using a single quantum cascade laser (QCL) device for both generation and sensing of THz radiation. Detection is achieved by utilizing the effect of self-mixing in the THz QCL, and, specifically, by monitoring perturbations to the voltage across the QCL, induced by light reflected from an external object back into the laser cavity. Self-mixing imaging offers high sensitivity, a potentially fast response, and a simple, compact optical design, and we show that it can be used to obtain high-resolution reflection images of exemplar structures.
Ståhlberg, Anders; Krzyzanowski, Paul M; Jackson, Jennifer B; Egyud, Matthew; Stein, Lincoln; Godfrey, Tony E
2016-06-20
Detection of cell-free DNA in liquid biopsies offers great potential for use in non-invasive prenatal testing and as a cancer biomarker. Fetal and tumor DNA fractions however can be extremely low in these samples and ultra-sensitive methods are required for their detection. Here, we report an extremely simple and fast method for introduction of barcodes into DNA libraries made from 5 ng of DNA. Barcoded adapter primers are designed with an oligonucleotide hairpin structure to protect the molecular barcodes during the first rounds of polymerase chain reaction (PCR) and prevent them from participating in mis-priming events. Our approach enables high-level multiplexing and next-generation sequencing library construction with flexible library content. We show that uniform libraries of 1-, 5-, 13- and 31-plex can be generated. Utilizing the barcodes to generate consensus reads for each original DNA molecule reduces background sequencing noise and allows detection of variant alleles below 0.1% frequency in clonal cell line DNA and in cell-free plasma DNA. Thus, our approach bridges the gap between the highly sensitive but specific capabilities of digital PCR, which only allows a limited number of variants to be analyzed, with the broad target capability of next-generation sequencing which traditionally lacks the sensitivity to detect rare variants. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.
Radikova, Z; Koska, J; Huckova, M; Ksinantova, L; Imrich, R; Vigas, M; Trnovec, T; Langer, P; Sebokova, E; Klimes, I
2006-05-01
Demanding measurement of insulin sensitivity using clamp methods does not simplify the identification of insulin resistant subjects in the general population. Other approaches such as fasting- or oral glucose tolerance test-derived insulin sensitivity indices were proposed and validated with the euglycemic clamp. Nevertheless, a lack of reference values for these indices prevents their wider use in epidemiological studies and clinical practice. The aim of our study was therefore to define the cut-off points of insulin resistance indices as well as the ranges of the most frequently obtained values for selected indices. A standard 75 g oral glucose tolerance test was carried out in 1156 subjects from a Caucasian rural population with no previous evidence of diabetes or other dysglycemias. Insulin resistance/sensitivity indices (HOMA-IR, HOMA-IR2, ISI Cederholm, and ISI Matsuda) were calculated. The 75th percentile value as the cut-off point to define IR corresponded with a HOMA-IR of 2.29, a HOMA-IR2 of 1.21, a 25th percentile for ISI Cederholm, and ISI Matsuda of 57 and 5.0, respectively. For the first time, the cut-off points for selected indices and their most frequently obtained values were established for groups of subjects as defined by glucose homeostasis and BMI. Thus, insulin-resistant subjects can be identified using this simple approach.
USE OF A SIMPLE THERMALISED NEUTRON FIELD FOR QUALITY ACCEPTANCE OF WHOLE BODY TLDS.
Gilvin, P J; Baker, S T; Eakins, J S; Tanner, R J
2016-09-01
The individual monitoring service of Public Health England (PHE) uses Harshaw™ whole-body and extremity thermoluminescent dosemeters (TLDs) with high-sensitivity lithium fluoride LiF:Mg,Cu,P, together with Harshaw 8800™ automated readers. The neutron-insensitive, (6)Li-depleted variety of TLD material is used by PHE because the service provides separate neutron and photon dosemeters. The neutron dosemeters are not sensitive to photons and vice versa Since insensitivity to neutrons is a supply requirement for TLDs, there is a need to test every new (annual) consignment for this. Because it is thermal neutrons that produce a response in (6)Li TLDs, a thermal field is needed. To this end, PHE has adopted the simple approach of sandwiching the TLDs between two ISO water-filled slab phantoms. In this arrangement, the fast neutrons from an Am-Be source are effectively thermalised. Details of the method are given, together with the results of supporting MCNP calculations and some typical results. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chromatic information and feature detection in fast visual analysis
Del Viva, Maria M.; Punzi, Giovanni; Shevell, Steven K.; ...
2016-08-01
The visual system is able to recognize a scene based on a sketch made of very simple features. This ability is likely crucial for survival, when fast image recognition is necessary, and it is believed that a primal sketch is extracted very early in the visual processing. Such highly simplified representations can be sufficient for accurate object discrimination, but an open question is the role played by color in this process. Rich color information is available in natural scenes, yet artist's sketches are usually monochromatic; and, black-andwhite movies provide compelling representations of real world scenes. Also, the contrast sensitivity ofmore » color is low at fine spatial scales. We approach the question from the perspective of optimal information processing by a system endowed with limited computational resources. We show that when such limitations are taken into account, the intrinsic statistical properties of natural scenes imply that the most effective strategy is to ignore fine-scale color features and devote most of the bandwidth to gray-scale information. We find confirmation of these information-based predictions from psychophysics measurements of fast-viewing discrimination of natural scenes. As a result, we conclude that the lack of colored features in our visual representation, and our overall low sensitivity to high-frequency color components, are a consequence of an adaptation process, optimizing the size and power consumption of our brain for the visual world we live in.« less
Chromatic information and feature detection in fast visual analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Del Viva, Maria M.; Punzi, Giovanni; Shevell, Steven K.
The visual system is able to recognize a scene based on a sketch made of very simple features. This ability is likely crucial for survival, when fast image recognition is necessary, and it is believed that a primal sketch is extracted very early in the visual processing. Such highly simplified representations can be sufficient for accurate object discrimination, but an open question is the role played by color in this process. Rich color information is available in natural scenes, yet artist's sketches are usually monochromatic; and, black-andwhite movies provide compelling representations of real world scenes. Also, the contrast sensitivity ofmore » color is low at fine spatial scales. We approach the question from the perspective of optimal information processing by a system endowed with limited computational resources. We show that when such limitations are taken into account, the intrinsic statistical properties of natural scenes imply that the most effective strategy is to ignore fine-scale color features and devote most of the bandwidth to gray-scale information. We find confirmation of these information-based predictions from psychophysics measurements of fast-viewing discrimination of natural scenes. As a result, we conclude that the lack of colored features in our visual representation, and our overall low sensitivity to high-frequency color components, are a consequence of an adaptation process, optimizing the size and power consumption of our brain for the visual world we live in.« less
Lei, Fang; Li, Chenglong; Zhou, Shuang; Wang, Dan; Zhao, Yunfeng; Wu, Yongning
2016-08-01
Aflatoxins (AFTs) are of great concern all over the world. Supercritical fluid chromatography (SFC) has the advantage of fast, high resolution and excellent compatibility with a broad range of organic solvents and samples, thus hyphenating SFC with tandem mass spectrometry (MS/MS) can be used for the easy and fast determination of AFTs in edible oils. Edible oil was spiked with isotope-labeled aflatoxin standards, diluted with hexane and extracted with acetonitrile. The extraction was directly loaded to an SFC apparatus and separated on a UPC(2) 2-EP column with CO2 -methanol gradient elution. A post-column make-up flow was introduced to facilitate mass spectrometry performance, and the mixture was analyzed by MS/MS with an electrospray ionization (ESI) source. The SFC conditions including separation column, modifier and sample solvent were optimized, and the four target aflatoxins were baseline separated. The ESI interface parameters were also investigated, implicating the make-up flow as a critical factor for sensitive determination by SFC-MS/MS. The LOQs for the AFTs were 0.05-0.12 μg L(-1) , while the RSDs were lower than 8.5%. Supercritical fluid chromatography was successfully coupled to tandem mass spectrometry to establish a simple, fast and sensitive method for the analysis of four aflatoxins in edible oil. This shows the combination of SFC-MS/MS has great potential in determination of trace contaminants in food. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Pieterse, Arwen H; de Vries, Marieke
2013-09-01
Increasingly, patient decision aids and values clarification methods (VCMs) are being developed to support patients in making preference-sensitive health-care decisions. Many VCMs encourage extensive deliberation about options, without solid theoretical or empirical evidence showing that deliberation is advantageous. Research suggests that simple, fast and frugal heuristic decision strategies sometimes result in better judgments and decisions. Durand et al. have developed two fast and frugal heuristic-based VCMs. To critically analyse the suitability of the 'take the best' (TTB) and 'tallying' fast and frugal heuristics in the context of patient decision making. Analysis of the structural similarities between the environments in which the TTB and tallying heuristics have been proven successful and the context of patient decision making and of the potential of these heuristic decision processes to support patient decision making. The specific nature of patient preference-sensitive decision making does not seem to resemble environments in which the TTB and tallying heuristics have proven successful. Encouraging patients to consider less rather than more relevant information potentially even deteriorates their values clarification process. Values clarification methods promoting the use of more intuitive decision strategies may sometimes be more effective. Nevertheless, we strongly recommend further theoretical thinking about the expected value of such heuristics and of other more intuitive decision strategies in this context, as well as empirical assessments of the mechanisms by which inducing such decision strategies may impact the quality and outcome of values clarification. © 2011 John Wiley & Sons Ltd.
Pieterse, Arwen H.; de Vries, Marieke
2011-01-01
Abstract Background Increasingly, patient decision aids and values clarification methods (VCMs) are being developed to support patients in making preference‐sensitive health‐care decisions. Many VCMs encourage extensive deliberation about options, without solid theoretical or empirical evidence showing that deliberation is advantageous. Research suggests that simple, fast and frugal heuristic decision strategies sometimes result in better judgments and decisions. Durand et al. have developed two fast and frugal heuristic‐based VCMs. Objective To critically analyse the suitability of the ‘take the best’ (TTB) and ‘tallying’ fast and frugal heuristics in the context of patient decision making. Strategy Analysis of the structural similarities between the environments in which the TTB and tallying heuristics have been proven successful and the context of patient decision making and of the potential of these heuristic decision processes to support patient decision making. Conclusion The specific nature of patient preference‐sensitive decision making does not seem to resemble environments in which the TTB and tallying heuristics have proven successful. Encouraging patients to consider less rather than more relevant information potentially even deteriorates their values clarification process. Values clarification methods promoting the use of more intuitive decision strategies may sometimes be more effective. Nevertheless, we strongly recommend further theoretical thinking about the expected value of such heuristics and of other more intuitive decision strategies in this context, as well as empirical assessments of the mechanisms by which inducing such decision strategies may impact the quality and outcome of values clarification. PMID:21902770
A square-wave adsorptive stripping voltammetric method for determination of fast green dye.
Al-Ghamdi, Ali F
2009-01-01
Square-wave adsorptive stripping voltammetric (SW-AdSV) determinations of trace concentrations of the coloring agent fast green were described. The analytical methodology used was based on the adsorptive preconcentration of the dye on the hanging mercury drop electrode, and then a negative sweep was initiated. In pH 10 carbonate supporting electrolyte, fast green gave a well-defined and sensitive SW-AdSV peak at -1220 mV. The electroanalytical determination of this dye was found to be optimized in carbonate buffer (pH 10) with the following experimental conditions: accumulation time (120 s); accumulation potential (-0.8 V); scan rate (800 mV/s); pulse amplitude (90 mV); frequency (90 Hz); surface area of the working electrode (0.6 mm2); and the convection rate (2000 rpm). Under these optimized conditions, the AdSV peak current was proportional over the concentration range 2 x 10(-8) -6 x 10(-7) M (r = 0.999), with an LOD of 1.63 x 10(-10) M (0.132 ppb). This analytical approach possessed more enhanced sensitivity than conventional chromatography or spectrophotometry, and was simple and quick. The precision of the method in terms of RSD was 0.17%, whereas the accuracy was evaluated via the mean recovery of 99.6%. Possible interferences by several substances usually present as food additive azo dyes (E110, E102, E123, and E129), natural and artificial sweeteners, and antioxidants were also investigated. Applicability of the developed electroanalysis method was illustrated via the determination of fast green in ice cream and soft drink samples.
NASA Astrophysics Data System (ADS)
Fu, Han; Liu, Hong; Shen, Wenzhong
2014-11-01
Fabricating functional compounds on substrates with complicated morphology has been an important topic in material science and technology, which remains a challenging issue to simultaneously achieve a high growth rate for a complex nanostructure with simple controlling factors. Here, we present a novel simple and successive method based on chemical reactions in an open reaction system manipulated by an electric field. A uniform CdS/TiO2 composite tubular structure has been fabricated in highly ordered TiO2 nanotube arrays in a very short time period (~90 s) under room temperature (RT). The content of CdS in the resultant and its crystalline structure was tuned by the form and magnitude of external voltage. The as-formed structure has shown a quite broad and bulk-like light absorption spectrum with the absorption of photon energy even below that of the bulk CdS. The as-fabricated-sensitized solar cell based on this composite structure has achieved an efficiency of 1.43% without any chemical doping or co-sensitizing, 210% higher than quantum dot-sensitized solar cell (QDSSC) under a similar condition. Hopefully, this method can also easily grow nanostructures based on a wide range of compound materials for energy science and electronic technologies, especially for fast-deploying devices.
2014-01-01
Background We aimed to evaluate the predictive utility of common fasting insulin sensitivity indices, and non-laboratory surrogates [BMI, waist circumference (WC) and waist-to-height ratio (WHtR)] in sub-Saharan Africans without diabetes. Methods We measured fasting glucose and insulin, and glucose uptake during 80/mU/m2/min euglycemic clamp in 87 Cameroonians (51 men) aged (SD) 34.6 (11.4) years. We derived insulin sensitivity indices including HOMA-IR, quantitative insulin sensitivity check index (QUICKI), fasting insulin resistance index (FIRI) and glucose-to-insulin ratio (GIR). Indices and clinical predictors were compared to clamp using correlation tests, robust linear regressions and agreement of classification by sex-specific thirds. Results The mean insulin sensitivity was M = 10.5 ± 3.2 mg/kg/min. Classification across thirds of insulin sensitivity by clamp matched with non-laboratory surrogates in 30-48% of participants, and with fasting indices in 27-51%, with kappa statistics ranging from −0.10 to 0.26. Fasting indices correlated significantly with clamp (/r/=0.23-0.30), with GIR performing less well than fasting insulin and HOMA-IR (both p < 0.02). BMI, WC and WHtR were equal or superior to fasting indices (/r/=0.38-0.43). Combinations of fasting indices and clinical predictors explained 25-27% of variation in clamp values. Conclusion Fasting insulin sensitivity indices are modest predictors of insulin sensitivity measured by euglycemic clamp, and do not perform better than clinical surrogates in this population. PMID:25106496
Brain State Effects on Layer 4 of the Awake Visual Cortex
Zhuang, Jun; Bereshpolova, Yulia; Stoelzel, Carl R.; Huff, Joseph M.; Hei, Xiaojuan; Alonso, Jose-Manuel
2014-01-01
Awake mammals can switch between alert and nonalert brain states hundreds of times per day. Here, we study the effects of alertness on two cell classes in layer 4 of primary visual cortex of awake rabbits: presumptive excitatory “simple” cells and presumptive fast-spike inhibitory neurons (suspected inhibitory interneurons). We show that in both cell classes, alertness increases the strength and greatly enhances the reliability of visual responses. In simple cells, alertness also increases the temporal frequency bandwidth, but preserves contrast sensitivity, orientation tuning, and selectivity for direction and spatial frequency. Finally, alertness selectively suppresses the simple cell responses to high-contrast stimuli and stimuli moving orthogonal to the preferred direction, effectively enhancing mid-contrast borders. Using a population coding model, we show that these effects of alertness in simple cells—enhanced reliability, higher gain, and increased suppression in orthogonal orientation—could play a major role at increasing the speed of cortical feature detection. PMID:24623767
Time variation of effective climate sensitivity in GCMs
NASA Astrophysics Data System (ADS)
Williams, K. D.; Ingram, W. J.; Gregory, J. M.
2009-04-01
Effective climate sensitivity is often assumed to be constant (if uncertain), but some previous studies of General Circulation Model (GCM) simulations have found it varying as the simulation progresses. This complicates the fitting of simple models to such simulations, as well as having implications for the estimation of climate sensitivity from observations. This study examines the evolution of the feedbacks determining the climate sensitivity in GCMs submitted to the Coupled Model Intercomparison Project. Apparent centennial-timescale variations of effective climate sensitivity during stabilisation to a forcing can be considered an artefact of using conventional forcings which only allow for instantaneous effects and stratospheric adjustment. If the forcing is adjusted for processes occurring on timescales which are short compared to the climate stabilisation timescale then there is little centennial timescale evolution of effective climate sensitivity in any of the GCMs. We suggest that much of the apparent variation in effective climate sensitivity identified in previous studies is actually due to the comparatively fast forcing adjustment. Persistent differences are found in the strength of the feedbacks between the coupled atmosphere - ocean (AO) versions and their atmosphere - mixed-layer ocean (AML) counterparts, (the latter are often assumed to give the equilibrium climate sensitivity of the AOGCM). The AML model can typically only estimate the equilibrium climate sensitivity of the parallel AO version to within about 0.5K. The adjustment to the forcing to account for comparatively fast processes varies in magnitude and sign between GCMs, as well as differing between AO and AML versions of the same model. There is evidence from one AOGCM that the forcing adjustment may take a couple of decades, with implications for observationally based estimates of equilibrium climate sensitivity. We suggest that at least some of the spread in 21st century global temperature predictions between GCMs is due to differing adjustment processes, hence work to understand these differences should be a priority.
El Awwa, A; Soliman, A; Al-Ali, M; Yassin, M; De Sanctis, V
2012-09-01
In obese adolescents pancreatic beta-cells may not be able to cope with insulin resistance leading to hyperglycemia and type2 diabetes (T2DM To assess oral glucose tolerance, 72-h continuous blood glucose concentrations (CGM) and calculate homeostatic model assessment (HOMA), and the quantitative insulin sensitivity check index (QUICKI) in 13 adolescents with simple obesity (BMI SDS=4 ± 1.06). OGTT performed in 13 obese adolescents (13.47 ± 3 years) revealed 3 cases (23%) with impaired fasting glucose (IFG: fasting glucose >5.6 mmol/L), 4 cases (30%) with impaired glucose tolerance (IGT: 2h blood glucose >7.8 <11.1 mmol/L), and none with diabetes. Using the continuous glucose monitoring system ( CGMS), IFG was detected in 4 cases, the maximum serum blood glucose (BG : 2h or more after meal) was >7.8 and <11.1 mmol/L (IGT) in 9 children (69%) and >11.1 mmol/L (diabetes) in one case (7.6%). Five cases had a minimum BG recorded of <2.7 mmol/L (hypoglycemia). No glycemic abnormality was detected using HbA1C (5.7 ± 0.3%). 11/13 patients had HOMA values >2.6 and QUICKI values <0.35 denoting insulin resistance. Beta cell mass percent (B %) = 200 ± 94.8% and insulin sensitivity values (IS)=50.4 ± 45.5% denoted insulin resistance with hyper-insulinaemia and preserved beta cell mass. In obese adolescents, CGMS is superior to OGTT and HbA1C in detecting glycemic abnormalities, which appears to be secondary to insulin resistance.
Flight Research into Simple Adaptive Control on the NASA FAST Aircraft
NASA Technical Reports Server (NTRS)
Hanson, Curtis E.
2011-01-01
A series of simple adaptive controllers with varying levels of complexity were designed, implemented and flight tested on the NASA Full-Scale Advanced Systems Testbed (FAST) aircraft. Lessons learned from the development and flight testing are presented.
Hu, Pengbing; Dong, Xinyong; Wong, Wei Chang; Chen, Li Han; Ni, Kai; Chan, Chi Chiu
2015-04-01
We present a simple photonic crystal fiber interferometer (PCFI) that operates in reflection mode for pH measurement. The sensor is made by coating polyvinyl alcohol/polyacrylic acid (PVA/PAA) hydrogel onto the surface of the PCFI, constructed by splicing a stub of PCF at the distal end of a single-mode fiber with its free end airhole collapsed. The experimental results demonstrate a high average sensitivity of 0.9 nm/pH unit for the 11 wt.% PVA/PAA coated sensor in the pH range from 2.5 to 6.5. The sensor also displays high repeatability and stability and low cross-sensitivity to temperature. Fast, reversible rise and fall times of 12 s and 18 s, respectively, are achieved for the sensor time response.
Gas sensing properties of very thin TiO2 films prepared by atomic layer deposition (ALD)
NASA Astrophysics Data System (ADS)
Boyadjiev, S.; Georgieva, V.; Vergov, L.; Baji, Zs; Gáber, F.; Szilágyi, I. M.
2014-11-01
Very thin titanium dioxide (TiO2) films of less than 10 nm were deposited by atomic layer deposition (ALD) in order to study their gas sensing properties. Applying the quartz crystal microbalance (QCM) method, prototype structures with the TiO2 ALD deposited thin films were tested for sensitivity to NO2. Although being very thin, the films were sensitive at room temperature and could register low concentrations as 50-100 ppm. The sorption is fully reversible and the films seem to be capable to detect for long term. These initial results for very thin ALD deposited TiO2 films give a promising approach for producing gas sensors working at room temperature on a fast, simple and cost-effective technology.
Determination of Diffusion Parameters of CO2 Through Microporous PTFE Using a Potentiometric Method
NASA Astrophysics Data System (ADS)
Tarsiche, I.; Ciurchea, D.
Dk values at the diffusion of CO2 through microporous PTFE of 1 to 7 × 10- 7 cm2 s- 1 in the concentration range from 4 × 10- 4 to 0.22 g/l CO2 are determined using a simple, fast and reliable potentiometric method. The method is based on the least-squares fitting of the potential versus time response of a self made CO2 sensitive Severinghaus type sensor with PTFE as a gas-permeable membrane. The obtained results are in good agreement with other reported literature data, both experimental or calculated ones using molecular dynamics simulations. The proposed technique is very sensitive especially at low concentrations of gas and may be used for the study of other polymeric membranes too.
Zhang, Wei; Tan, Shenglan; Paintsil, Elijah; Dutschman, Ginger E.; Gullen, Elizabeth A.; Chu, Edward; Cheng, Yung-Chi
2011-01-01
Endogenous ribonucleotides and deoxyribonucleotides play a critical role in cell function, and determination of their levels is of fundamental importance in understanding key cellular processes involved in energy metabolism and molecular and biochemical signaling pathways. In this study, we determined the respective ribonucleotide and deoxyribonucleotide pool sizes in different human cell lines using a simple sample preparation method and LC/MS/MS. This assay was used to determine alterations in deoxyribonucleotide pools in human pancreatic PANC-1 cells in response to hypoxia and to treatment with either hydroxyurea or aphidicolin. The levels of all deoxyribonucleotide metabolites decreased with hypoxia treatment, except for dUMP, which increased by two-fold. This LC/MS/MS assay is simple, fast, and sensitive, and it represents a significant advance over previously published methodologies. PMID:21620803
Saleh, Tawfik A; Abulkibash, A M; Ibrahim, Atta E
2012-04-01
A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective.
Wang, Yonglan; Jin, Jun; Yuan, Caixia; Zhang, Fan; Ma, Linlin; Qin, Dongdong; Shan, Duoliang; Lu, Xiaoquan
2015-01-21
A simple and mild strategy was proposed to develop a novel electrochemical sensor based on zirconia/ordered macroporous polyaniline (ZrO2/OMP) and further used for the detection of methyl parathion (MP), one of the organophosphate pesticides (OPPs). Due to the strong affinity of phosphate groups with ZrO2 and the advantages of OMP such as high catalytic activity and good conductivity, the developed sensor showed a limit of detection as low as 2.28 × 10(-10) mol L(-1) (S/N = 3) by square-wave voltammograms, and good selectivity, acceptable reproducibility and stability. Most importantly, this novel sensor was successfully applied to detect MP in real samples of apple and cabbage. It is expected that this method has potential applications in electrochemical sensing platforms with simple, sensitive, selective and fast analysis.
Normative Data for an Instrumental Assessment of the Upper-Limb Functionality.
Caimmi, Marco; Guanziroli, Eleonora; Malosio, Matteo; Pedrocchi, Nicola; Vicentini, Federico; Molinari Tosatti, Lorenzo; Molteni, Franco
2015-01-01
Upper-limb movement analysis is important to monitor objectively rehabilitation interventions, contributing to improving the overall treatments outcomes. Simple, fast, easy-to-use, and applicable methods are required to allow routinely functional evaluation of patients with different pathologies and clinical conditions. This paper describes the Reaching and Hand-to-Mouth Evaluation Method, a fast procedure to assess the upper-limb motor control and functional ability, providing a set of normative data from 42 healthy subjects of different ages, evaluated for both the dominant and the nondominant limb motor performance. Sixteen of them were reevaluated after two weeks to perform test-retest reliability analysis. Data were clustered into three subgroups of different ages to test the method sensitivity to motor control differences. Experimental data show notable test-retest reliability in all tasks. Data from older and younger subjects show significant differences in the measures related to the ability for coordination thus showing the high sensitivity of the method to motor control differences. The presented method, provided with control data from healthy subjects, appears to be a suitable and reliable tool for the upper-limb functional assessment in the clinical environment.
Normative Data for an Instrumental Assessment of the Upper-Limb Functionality
Caimmi, Marco; Guanziroli, Eleonora; Malosio, Matteo; Pedrocchi, Nicola; Vicentini, Federico; Molinari Tosatti, Lorenzo; Molteni, Franco
2015-01-01
Upper-limb movement analysis is important to monitor objectively rehabilitation interventions, contributing to improving the overall treatments outcomes. Simple, fast, easy-to-use, and applicable methods are required to allow routinely functional evaluation of patients with different pathologies and clinical conditions. This paper describes the Reaching and Hand-to-Mouth Evaluation Method, a fast procedure to assess the upper-limb motor control and functional ability, providing a set of normative data from 42 healthy subjects of different ages, evaluated for both the dominant and the nondominant limb motor performance. Sixteen of them were reevaluated after two weeks to perform test-retest reliability analysis. Data were clustered into three subgroups of different ages to test the method sensitivity to motor control differences. Experimental data show notable test-retest reliability in all tasks. Data from older and younger subjects show significant differences in the measures related to the ability for coordination thus showing the high sensitivity of the method to motor control differences. The presented method, provided with control data from healthy subjects, appears to be a suitable and reliable tool for the upper-limb functional assessment in the clinical environment. PMID:26539500
Shan, Chen-Xiao; Cui, Xiao-Bing; Yu, Sheng; Chai, Chuan; Wen, Hong-Mei; Wang, Xin-Zhi; Sun, Xue
2016-01-01
3,4-Divanillyltetrahydrofuran is the main active ingredient of nettle root which can increase steroid hormones in the bloodstream for many of bodybuilders. To better understand its pharmacological activities, we need to determine its pharmacokinetic profiles. In this study, a rapid and sensitive ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed for the determination of 3,4-divanillyltetrahydrofuran in the plasma of rats. Chromatographic separation was performed on a C18 column at 40°C, with a gradient elution consisting of methanol and water containing 0.3% (v/v) formic acid at a flow rate of 0.8mL/min. The detection was performed using an electrospray triple-quadrupole MS/MS via positive ion multiple reaction monitoring mode. The lower limits-of-quantification determined were 0.5ng/mL. The intra- and inter-day precision (RSD%) was found to be within 15% and the accuracy (RE%) ranged from -4.0% to 7.0%. This simple yet sensitive method was fully validated and could be successfully applied to the study on pharmacokinetics of 3, 4-divanillyltetrahydrofuran. Copyright © 2015 Elsevier B.V. All rights reserved.
A novel and fast method for proton range verification using a step wedge and 2D scintillator.
Shen, Jiajian; Allred, Bryce C; Robertson, Daniel G; Liu, Wei; Sio, Terence T; Remmes, Nicholas B; Keole, Sameer R; Bues, Martin
2017-09-01
To implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge. A homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge. The range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements. A novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible. © 2017 American Association of Physicists in Medicine.
A webcam in Bayer-mode as a light beam profiler for the near infra-red
Langer, Gregor; Hochreiner, Armin; Burgholzer, Peter; Berer, Thomas
2013-01-01
Beam profiles are commonly measured with complementary metal oxide semiconductors (CMOS) or charge coupled devices (CCD). The devices are fast and reliable but expensive. By making use of the fact that the Bayer-filter in commercial webcams is transparent in the near infra-red (>800 nm) and their CCD chips are sensitive up to about 1100 nm, we demonstrate a cheap and simple way to measure laser beam profiles with a resolution down to around ±1 μm, which is close to the resolution of the knife-edge technique. PMID:23645943
Optical biosensor based on liquid crystal droplets for detection of cholic acid
NASA Astrophysics Data System (ADS)
Niu, Xiaofang; Luo, Dan; Chen, Rui; Wang, Fei; Sun, Xiaowei; Dai, Haitao
2016-12-01
A highly sensitive cholic acid biosensor based on 4-cyano-4‧-penthlbiphenyl (5CB) Liquid crystal droplets in phosphate buffer saline solution was reported. A radial-to-bipolar transition of 5CB droplet would be triggered during competitive reaction of CA at the sodium dodecyl sulfate surfactant-laden 5CB droplet surface. Our liquid crystal droplet sensor is a low-cost, simple and fast method for CA detection. The detection limit (5 μM) of our method is 2.4 times lower than previously report by using liquid crystal film to detection of CA.
A webcam in Bayer-mode as a light beam profiler for the near infra-red.
Langer, Gregor; Hochreiner, Armin; Burgholzer, Peter; Berer, Thomas
2013-05-01
Beam profiles are commonly measured with complementary metal oxide semiconductors (CMOS) or charge coupled devices (CCD). The devices are fast and reliable but expensive. By making use of the fact that the Bayer-filter in commercial webcams is transparent in the near infra-red (>800 nm) and their CCD chips are sensitive up to about 1100 nm, we demonstrate a cheap and simple way to measure laser beam profiles with a resolution down to around ±1 μm, which is close to the resolution of the knife-edge technique.
Sekuła, Justyna; Nizioł, Joanna; Rode, Wojciech; Ruman, Tomasz
2015-05-22
Preparation is described of a durable surface of cationic gold nanoparticles (AuNPs), covering commercial and custom-made MALDI targets, along with characterization of the nanoparticle surface properties and examples of the use in MS analyses and MS imaging (IMS) of low molecular weight (LMW) organic compounds. Tested compounds include nucleosides, saccharides, amino acids, glycosides, and nucleic bases for MS measurements, as well as over one hundred endogenous compounds in imaging experiment. The nanoparticles covering target plate were enriched in sodium in order to promote sodium-adduct formation. The new surface allows fast analysis, high sensitivity of detection and high mass determination accuracy. Example of application of new Au nanoparticle-enhanced target for fast and simple MS imaging of a fingerprint is also presented. Copyright © 2015 Elsevier B.V. All rights reserved.
Fast Responding Oxygen Sensor For Respiratorial Analysis
NASA Astrophysics Data System (ADS)
Karpf, Hellfried H.; Kroneis, H. W.; Marsoner, Hermann J.; Metzler, H.; Gravenstein, N.
1990-02-01
Breath-by-breath monitoring of the partial pressure of oxygen is the main interest for the development of a fast responding optical oxygen sensor. Monitoring the P02 finds its main interest in critical care, in artificial respiration, in breath by breath determination of respiratorial coefficients and in pulmonarial examinations. The requirements arising from these and similar applications are high precision, high long term stability, and time constants in the range of less than 0.1 sec. In order to cope with these requirements, we investigated different possibilities of fast P02-measurements by means of optical sensors based on fluorescence quenching. The experimental set up is simple: a rigid transparent layer is coated with a thin layer of an hydrophobic polymer which has a high permeability for oxygen. The oxygen sensitive indicator material is embedded into this polymer. An experimental set up showed time constants of 30 milliseconds. The lifetime is in the range of several months. Testing of our test equipment by an independent working group resulted in surprisingly good correlation with data obtained by mass spectroscopy.
NASA Astrophysics Data System (ADS)
England, Troy; Curry, Matthew; Carr, Steve; Swartzentruber, Brian; Lilly, Michael; Bishop, Nathan; Carrol, Malcolm
2015-03-01
Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance typical of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will discuss calibration data, as well as modeling and simulation of cryogenic silicon-germanium (SiGe) heterojunction bipolar transistor (HBT) circuits connected to a silicon SET and operating at 4 K. We find a continuum of solutions from simple, single-HBT amplifiers to more complex, multi-HBT circuits suitable for integration, with varying noise levels and power vs. bandwidth tradeoffs. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.
Povedano, Eloy; Vargas, Eva; Montiel, Víctor Ruiz-Valdepeñas; Torrente-Rodríguez, Rebeca M; Pedrero, María; Barderas, Rodrigo; Segundo-Acosta, Pablo San; Peláez-García, Alberto; Mendiola, Marta; Hardisson, David; Campuzano, Susana; Pingarrón, José M
2018-04-23
This paper describes two different electrochemical affinity biosensing approaches for the simple, fast and bisulfite and PCR-free quantification of 5-methylated cytosines (5-mC) in DNA using the anti-5-mC antibody as biorecognition element. One of the biosensing approaches used the anti-5-mC as capture bioreceptor and a sandwich type immunoassay, while the other one involved the use of a specific DNA probe and the anti-5-mC as a detector bioreceptor of the captured methylated DNA. Both strategies, named for simplicity in the text as immunosensor and DNA sensor, respectively, were implemented on the surface of magnetic microparticles and the transduction was accomplished by amperometry at screen-printed carbon electrodes by means of the hydrogen peroxide/hydroquinone system. The resulting amperometric biosensors demonstrated reproducibility throughout the entire protocol, sensitive determination with no need for using amplification strategies, and competitiveness with the conventional enzyme-linked immunosorbent assay methodology and the few electrochemical biosensors reported so far in terms of simplicity, sensitivity and assay time. The DNA sensor exhibited higher sensitivity and allowed the detection of the gene-specific methylations conversely to the immunosensor, which detected global DNA methylation. In addition, the DNA sensor demonstrated successful applicability for 1 h-analysis of specific methylation in two relevant tumor suppressor genes in spiked biological fluids and in genomic DNA extracted from human glioblastoma cells.
Zhu, Bangjie; Liu, Feng; Li, Xituo; Wang, Yan; Gu, Xue; Dai, Jieyu; Wang, Guiming; Cheng, Yu; Yan, Chao
2015-01-01
Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at -20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Guodong; Lin, Yuehe
2005-09-15
Electrochemical sensor for detection of organophosphate (OP) pesticides and nerve agents using zirconia (ZrO₂) nanoparticles as selective sorbents is presented. Zirconia nanoparticles were electrodynamically deposited onto the polycrystalline gold electrode by cyclic voltammetry. Because of a strong affinity of zirconia to the phosphoric group, nitroaromatic OPs strongly bind to the ZrO₂ nanoparticle surface. The electrochemical characterization and anodic stripping voltammetric performance of bound OPs were evaluated using cyclic voltammetric and square-wave voltammetric (SWV) analysis. SWV was used to monitor the amount of bound OPs and provide simple, fast, and facile quantitative methods for nitroaromatic OP compounds. The sensor surface canmore » be regenerated by successively running SWV scanning. Operational parameters, including the amount of nanoparticles, adsorption time, and the pH of the reaction medium have been optimized. The stripping voltammetric response is highly linear over the 5–200 ng/mL (ppb) methyl parathion range examined (2-min adsorption), with a detection limit of 1 ng/mL (10 min accumulation), and good precision (RSD=5.3 %, n = 10). The promising stripping voltammetric performances open new opportunities for fast, simple, and sensitive analyzing of OPs in environmental and biological samples. These findings can lead to a widespread use of electrochemical sensors to detect OP contaminates.« less
Delensing CMB polarization with external datasets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Kendrick M.; Hanson, Duncan; LoVerde, Marilena
2012-06-01
One of the primary scientific targets of current and future CMB polarization experiments is the search for a stochastic background of gravity waves in the early universe. As instrumental sensitivity improves, the limiting factor will eventually be B-mode power generated by gravitational lensing, which can be removed through use of so-called ''delensing'' algorithms. We forecast prospects for delensing using lensing maps which are obtained externally to CMB polarization: either from large-scale structure observations, or from high-resolution maps of CMB temperature. We conclude that the forecasts in either case are not encouraging, and that significantly delensing large-scale CMB polarization requires high-resolutionmore » polarization maps with sufficient sensitivity to measure the lensing B-mode. We also present a simple formalism for including delensing in CMB forecasts which is computationally fast and agrees well with Monte Carlos.« less
NASA Astrophysics Data System (ADS)
Palve, Yogesh Pandit; Jha, Neetu
2018-05-01
In this research work we have developed high sensitive and selective glucose sensor based on copper oxide-graphene composite which is prepared by green synthesis method and used for nonenzymatic glucose sensor. In present paper we report that present method highly selective, simple, efficient, accurate, ecofriendly, less toxic. The prepared composite were characterized by material characterization like SEM, XRD and also by electrochemical characterization like CV, chronoamperometry represents that copper oxide-graphene shows excellent electrocatalytic activity towards glucose, exhibiting a good sensitivity of 103.84 µA mM-1 cm-2, a fast response time 2s, a low detection limit 0.00033µM and linear range from 10 µM-3000 µM. The present sensor can successfully apply for determination of glucose concentration in human blood sample.
Bever, Candace S; Barnych, Bogdan; Hnasko, Robert; Cheng, Luisa W; Stanker, Larry H
2018-06-28
One of the deadliest mushrooms is the death cap mushroom, Amanita phalloides . The most toxic constituent is α-amanitin, a bicyclic octapeptide, which damages the liver and kidneys. To develop a new tool for detecting this toxin, polyclonal antibodies were generated and characterized. Both α- and β-amanitin were coupled to carrier proteins through four different linking chemistries, one of which has never before been described. These conjugates were evaluated for their effectiveness in generating antibodies specific for the free toxin, as well as their utility in formatting heterogeneous assays with high sensitivity. Ultimately, these efforts yielded a newly described conjugation procedure utilizing periodate oxidation followed by reductive amination that successfully resulted in generating sensitive immunoassays (limit of detection (LOD), ~1.0 µg/L). The assays were characterized for their selectivity and were found to equally detect α-, β-, and γ-amanitin, and not cross-react with other toxins tested. Toxin detection in mushrooms was possible using a simple sample preparation method. This enzyme-linked immunosorbent assay (ELISA) is a simple and fast test, and readily detects amatoxins extracted from A. phalloides .
NASA Astrophysics Data System (ADS)
Guerrini, Luca; Morla-Folch, Judit; Gisbert-Quilis, Patricia; Xie, Hainan; Alvarez-Puebla, Ramon
2016-03-01
Recently, plasmonic-based biosensing has experienced an unprecedented level of attention, with a particular focus on the nucleic acid detection, offering efficient solutions to engineer simple, fast, highly sensitive sensing platforms while overcoming important limitations of PCR and microarray techniques. In the broad field of plasmonics, surface-enhanced Raman scattering (SERS) spectroscopy has arisen as a powerful analytical tool for detection and structural characterization of biomolecules. Today applications of SERS to nucleic acid analysis largely rely on indirect strategies, which have been demonstrated very effective for pure sensing purposes but completely dismiss the exquisite structural information provided by the direct acquisition of the biomolecular vibrational fingerprint. Contrarily, direct label-free SERS of nucleic acid shows an outstanding potential in terms of chemical-specific information which, however, remained largely unexpressed mainly because of the inherent poor spectral reproducibility and/or limited sensitivity. To address these limitations, we developed a fast and affordable high-throughput screening direct SERS method for gaining detailed genomic information on nucleic acids (DNA and RNA) and for the characterization and quantitative recognition of DNA interactions with exogenous agents. The simple strategy relies on the electrostatic adhesion of DNA/RNA onto positively-charged silver colloids that promotes the nanoparticle aggregation into stable clusters yielding intense and reproducible SERS spectra at picogram level (i.e. the analysis can be performed without the necessity of amplification steps thus providing realistic direct information of the nucleic acid in its native state). We anticipate this method to gain a vast impact and set of applications in different fields, including medical diagnostics, genomic screening, drug discovery, forensic science and even molecular electronics.
Saleh, Tawfik A.; Abulkibash, A.M.; Ibrahim, Atta E.
2011-01-01
A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective. PMID:23960787
Alnasser, Yossef; Ferradas, Cusi; Clark, Taryn; Calderon, Maritza; Gurbillon, Alejandro; Gamboa, Dionicia; McKakpo, Uri S.; Quakyi, Isabella A.; Bosompem, Kwabena M.; Sullivan, David J.; Vinetz, Joseph M.; Gilman, Robert H.
2016-01-01
Plasmodium vivax is the most prevalent cause of human malaria in the world and can lead to severe disease with high potential for relapse. Its genetic and geographic diversities make it challenging to control. P. vivax is understudied and to achieve control of malaria in endemic areas, a rapid, accurate, and simple diagnostic tool is necessary. In this pilot study, we found that a colorimetric system using AuNPs and MSP10 DNA detection in urine can provide fast, easy, and inexpensive identification of P. vivax. The test exhibited promising sensitivity (84%), high specificity (97%), and only mild cross-reactivity with P. falciparum (21%). It is simple to use, with a visible color change that negates the need for a spectrometer, making it suitable for use in austere conditions. Using urine eliminates the need for finger-prick, increasing both the safety profile and patient acceptance of this model. PMID:27706158
Purposeful Variable Selection and Stratification to Impute Missing FAST Data in Trauma Research
Fuchs, Paul A.; del Junco, Deborah J.; Fox, Erin E.; Holcomb, John B.; Rahbar, Mohammad H.; Wade, Charles A.; Alarcon, Louis H.; Brasel, Karen J.; Bulger, Eileen M.; Cohen, Mitchell J.; Myers, John G.; Muskat, Peter; Phelan, Herb A.; Schreiber, Martin A.; Cotton, Bryan A.
2013-01-01
Background The Focused Assessment with Sonography for Trauma (FAST) exam is an important variable in many retrospective trauma studies. The purpose of this study was to devise an imputation method to overcome missing data for the FAST exam. Due to variability in patients’ injuries and trauma care, these data are unlikely to be missing completely at random (MCAR), raising concern for validity when analyses exclude patients with missing values. Methods Imputation was conducted under a less restrictive, more plausible missing at random (MAR) assumption. Patients with missing FAST exams had available data on alternate, clinically relevant elements that were strongly associated with FAST results in complete cases, especially when considered jointly. Subjects with missing data (32.7%) were divided into eight mutually exclusive groups based on selected variables that both described the injury and were associated with missing FAST values. Additional variables were selected within each group to classify missing FAST values as positive or negative, and correct FAST exam classification based on these variables was determined for patients with non-missing FAST values. Results Severe head/neck injury (odds ratio, OR=2.04), severe extremity injury (OR=4.03), severe abdominal injury (OR=1.94), no injury (OR=1.94), other abdominal injury (OR=0.47), other head/neck injury (OR=0.57) and other extremity injury (OR=0.45) groups had significant ORs for missing data; the other group odds ratio was not significant (OR=0.84). All 407 missing FAST values were imputed, with 109 classified as positive. Correct classification of non-missing FAST results using the alternate variables was 87.2%. Conclusions Purposeful imputation for missing FAST exams based on interactions among selected variables assessed by simple stratification may be a useful adjunct to sensitivity analysis in the evaluation of imputation strategies under different missing data mechanisms. This approach has the potential for widespread application in clinical and translational research and validation is warranted. Level of Evidence Level II Prognostic or Epidemiological PMID:23778515
2014-01-01
Fabricating functional compounds on substrates with complicated morphology has been an important topic in material science and technology, which remains a challenging issue to simultaneously achieve a high growth rate for a complex nanostructure with simple controlling factors. Here, we present a novel simple and successive method based on chemical reactions in an open reaction system manipulated by an electric field. A uniform CdS/TiO2 composite tubular structure has been fabricated in highly ordered TiO2 nanotube arrays in a very short time period (~90 s) under room temperature (RT). The content of CdS in the resultant and its crystalline structure was tuned by the form and magnitude of external voltage. The as-formed structure has shown a quite broad and bulk-like light absorption spectrum with the absorption of photon energy even below that of the bulk CdS. The as-fabricated-sensitized solar cell based on this composite structure has achieved an efficiency of 1.43% without any chemical doping or co-sensitizing, 210% higher than quantum dot-sensitized solar cell (QDSSC) under a similar condition. Hopefully, this method can also easily grow nanostructures based on a wide range of compound materials for energy science and electronic technologies, especially for fast-deploying devices. PMID:25520588
Frølund, Maria; Björnelius, Eva; Lidbrink, Peter; Ahrens, Peter; Jensen, Jørgen Skov
2014-01-01
A novel multiplex quantitative real-time polymerase chain reaction (qPCR) for simultaneous detection of U. urealyticum and U. parvum was developed and compared with quantitative culture in Shepard's 10 C medium for ureaplasmas in urethral swabs from 129 men and 66 women, and cervical swabs from 61 women. Using culture as the gold standard, the sensitivity of the qPCR was 96% and 95% for female urethral and cervical swabs, respectively. In male urethral swabs the sensitivity was 89%. The corresponding specificities were 100%, 87% and 99%. The qPCR showed a linear increasing DNA copy number with increasing colour-changing units. Although slightly less sensitive than culture, this multiplex qPCR assay detecting U. urealyticum and U. parvum constitutes a simple and fast alternative to the traditional methods for identification of ureaplasmas and allows simultaneous species differentiation and quantitation in clinical samples. Furthermore, specimens overgrown by other bacteria using the culture method can be evaluated in the qPCR.
Sun, Qi-Jun; Zhuang, Jiaqing; Venkatesh, Shishir; Zhou, Ye; Han, Su-Ting; Wu, Wei; Kong, Ka-Wai; Li, Wen-Jung; Chen, Xianfeng; Li, Robert K Y; Roy, Vellaisamy A L
2018-01-31
Piezoresistive microsensors are considered to be essential components of the future wearable electronic devices. However, the expensive cost, complex fabrication technology, poor stability, and low yield have limited their developments for practical applications. Here, we present a cost-effective, relatively simple, and high-yield fabrication approach to construct highly sensitive and ultrastable piezoresistive sensors using a bioinspired hierarchically structured graphite/polydimethylsiloxane composite as the active layer. In this fabrication, a commercially available sandpaper is employed as the mold to develop the hierarchical structure. Our devices exhibit fascinating performance including an ultrahigh sensitivity (64.3 kPa -1 ), fast response time (<8 ms), low limit of detection of 0.9 Pa, long-term durability (>100 000 cycles), and high ambient stability (>1 year). The applications of these devices in sensing radial artery pulses, acoustic vibrations, and human body motion are demonstrated, exhibiting their enormous potential use in real-time healthcare monitoring and robotic tactile sensing.
Yaman, Yesim Tugce; Abaci, Serdar
2016-01-01
A novel electrochemical sensor gold nanoparticle (AuNP)/polyvinylpyrrolidone (PVP) modified pencil graphite electrode (PGE) was developed for the ultrasensitive determination of Bisphenol A (BPA). The gold nanoparticles were electrodeposited by constant potential electrolysis and PVP was attached by passive adsorption onto the electrode surface. The electrode surfaces were characterized by electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The parameters that affected the experimental conditions were researched and optimized. The AuNP/PVP/PGE sensor provided high sensitivity and selectivity for BPA recognition by using square wave adsorptive stripping voltammetry (SWAdSV). Under optimized conditions, the detection limit was found to be 1.0 nM. This new sensor system offered the advantages of simple fabrication which aided the expeditious replication, low cost, fast response, high sensitivity and low background current for BPA. This new sensor system was successfully tested for the detection of the amount of BPA in bottled drinking water with high reliability. PMID:27231912
Tian, He; Wang, Jiaqi; Zhang, Yangdong; Li, Songli; Jiang, Jindou; Tao, Dali; Zheng, Nan
2016-10-15
A simple and fast multiresidue extraction and purification method was developed for the determination of 61 veterinary drugs, belonging to seven classes, in milk and milk powder. The extraction depends on the acetonitrile solvent, followed by a single step to remove lipids with fatty acid chains using a new reversed phase SPE without traditional pre-equilibration and washing steps before eluting SPE. The purifying lipid effect of the present preparation method was evaluated by comparing the response changes of ion peak areas of the milk endogenous metabolites before and after SPE treatment using ultra-fast LC coupled to tandem quadrupole and TOF MS. Subsequently, UPLC coupled to tandem quadrupole MS was performed for the quantitative analysis of milk and milk powder samples spiked with 61 veterinary drugs, including β-lactam, macrolide, amide alcohol, forest amine, sulfanilamide, tetracyclines, and quinolones antibiotics. This method is very simple, fast, sensitive, and selective, and allows the good recoveries of all compounds, with a recovery range of 61.5-118.6%, and coefficients of variation of less than 11.6%. The 61 compounds behave in the dynamic range 0.01-200μgkg(-1), with correlation coefficient >0.99. The limits of quantification for the analytes are in the range 0.01-5.18μgkg(-1). Finally, this method has been successfully applied to the screening of veterinary drugs in 50 commercial bovine milk and milk powder samples, and ceftiofur and ciprofloxacin were detected in some brand samples. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Kanmi
The development of fast magic angle spinning (MAS) opened up an opportunity for the indirect detection of insensitive low-γ nuclei (e.g., 13C and 15N) via the sensitive high-{gamma} nuclei (e.g., 1H and 19F) in solid-state NMR, with advanced sensitivity and resolution. In this thesis, new methodology utilizing fast MAS is presented, including through-bond indirectly detected heteronuclear correlation (HETCOR) spectroscopy, which is assisted by multiple RF pulse sequences for 1H- 1H homonuclear decoupling. Also presented is a simple new strategy for optimization of 1H- 1H homonuclear decoupling. As applications, various classes of materials, such as catalytic nanoscale materials, biomolecules, and organic complexes, are studied by combining indirect detection and other one-dimensional (1D) and two-dimensional (2D) NMR techniques. Indirectly detected through-bond HETCOR spectroscopy utilizing refocused INEPT (INEPTR) mixing was developed under fast MAS (Chapter 2). The time performance of this approach in 1H detected 2D 1H{l_brace} 13C{r_brace} spectra was significantly improved, by a factor of almost 10, compared to the traditional 13C detected experiments, as demonstrated by measuring naturally abundant organic-inorganic mesoporous hybrid materials. The through-bond scheme was demonstrated as a new analytical tool, which provides complementary structural information in solid-state systems in addition to through-space correlation. To further benefit the sensitivity of the INEPT transfer in rigid solids, the combined rotation and multiple-pulse spectroscopy (CRAMPS) was implemented for homonuclear 1H decoupling under fast MAS (Chapter 3). Several decoupling schemes (PMLG5 m more » $$\\bar{x}$$, PMLG5 mm $$\\bar{x}$$x and SAM3) were analyzed to maximize the performance of through-bond transfer based on decoupling efficiency as well as scaling factors. Indirect detection with assistance of PMLG m $$\\bar{x}$$ during INEPTR transfer proved to offer the highest sensitivity gains of 3-10. In addition, the CRAMPS sequence was applied under fast MAS to increase the 1H resolution during t 1 evolution in the traditional, 13C detected HETCOR scheme. Two naturally abundant solids, tripeptide N-formyl-L-methionyl-L-leucyl-L-phenylalanine (f-MLF-OH) and brown coal, with well ordered and highly disordered structures, respectively, are studied to confirm the capabilities of these techniques. Concomitantly, a simple optimization of 1H homonuclear dipolar decoupling at MAS rates exceeding 10 kHz was developed (Chapter 4). The fine-tuned decoupling efficiency can be obtained by minimizing the signal loss due to transverse relaxation in a simple spin-echo experiment, using directly the sample of interest. The excellent agreement between observed decoupling pattern and earlier theoretical predictions confirmed the utility of this strategy. The properties of naturally abundant surface-bound fluorocarbon groups in mesoporous silica nanoparticles (MSNs) were investigated by the above-mentioned multidimensional solid-state NMR experiments and theoretical modeling (Chapter 5). Two conformations of (pentafluorophenyl)propyl groups (abbreviated as PFP) were determined as PFP-prone and PFP-upright, whose aromatic rings are located above the siloxane bridges and in roughly upright position, respectively. Several 1D and 2D NMR techniques were implemented in the characterizations, including indirectly detected 1H{l_brace} 13C{r_brace} and 19F{l_brace} 13C{r_brace} 2D HETCOR, Carr-Purcell-Meiboom-Gill (CPMG) assisted 29Si direct polarization and 29Si 19F 2D experiments, 2D double-quantum (DQ) 19F MAS NMR spectra and spin-echo measurements. Furthermore, conformational details of two types of PFP were confirmed by theoretical calculation, operated by Dr. Takeshi Kobayashi. Finally, the arrangement of two surfactants, cetyltrimetylammoium bromide (CTAB) and cetylpyridinium bromide (CPB), mixed inside the MSN pores, was studied by solid-state NMR (Chapter 6). By analyzing the 1H- 1H DQMAS and NOESY correlation spectra, the CTAB and CPB molecules were shown to co-exist inside the pores without forming significant monocomponent domains. A 'folded-over' conformation of CPB headgroups was proposed according to the results from 1H- 29Si 2D HETCOR.« less
NASA Astrophysics Data System (ADS)
Ghaffarian, Saman; Ghaffarian, Salar
2014-11-01
This paper proposes an improved FastICA model named as Purposive FastICA (PFICA) with initializing by a simple color space transformation and a novel masking approach to automatically detect buildings from high resolution Google Earth imagery. ICA and FastICA algorithms are defined as Blind Source Separation (BSS) techniques for unmixing source signals using the reference data sets. In order to overcome the limitations of the ICA and FastICA algorithms and make them purposeful, we developed a novel method involving three main steps: 1-Improving the FastICA algorithm using Moore-Penrose pseudo inverse matrix model, 2-Automated seeding of the PFICA algorithm based on LUV color space and proposed simple rules to split image into three regions; shadow + vegetation, baresoil + roads and buildings, respectively, 3-Masking out the final building detection results from PFICA outputs utilizing the K-means clustering algorithm with two number of clusters and conducting simple morphological operations to remove noises. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.6% and 85.5% overall pixel-based and object-based precision performances, respectively.
Morinha, Francisco; Travassos, Paulo; Seixas, Fernanda; Santos, Nuno; Sargo, Roberto; Sousa, Luís; Magalhães, Paula; Cabral, João A; Bastos, Estela
2013-05-01
High-resolution melting (HRM) analysis is a very attractive and flexible advanced post-PCR method with high sensitivity/specificity for simple, fast and cost-effective genotyping based on the detection of specific melting profiles of PCR products. Next generation real-time PCR systems, along with improved saturating DNA-binding dyes, enable the direct acquisition of HRM data after quantitative PCR. Melting behaviour is particularly influenced by the length, nucleotide sequence and GC content of the amplicons. This method is expanding rapidly in several research areas such as human genetics, reproductive biology, microbiology and ecology/conservation of wild populations. Here we have developed a successful HRM protocol for avian sex identification based on the amplification of sex-specific CHD1 fragments. The melting curve patterns allowed efficient sexual differentiation of 111 samples analysed (plucked feathers, muscle tissues, blood and oral cavity epithelial cells) of 14 bird species. In addition, we sequenced the amplified regions of the CHD1 gene and demonstrated the usefulness of this strategy for the genotype discrimination of various amplicons (CHD1Z and CHD1W), which have small size differences, ranging from 2 bp to 44 bp. The established methodology clearly revealed the advantages (e.g. closed-tube system, high sensitivity and rapidity) of a simple HRM assay for accurate sex differentiation of the species under study. The requirements, strengths and limitations of the method are addressed to provide a simple guide for its application in the field of molecular sexing of birds. The high sensitivity and resolution relative to previous real-time PCR methods makes HRM analysis an excellent approach for improving advanced molecular methods for bird sexing. © 2013 Blackwell Publishing Ltd.
Leininger, Elizabeth C.; Kitayama, Ken; Kelley, Darcy B.
2015-01-01
ABSTRACT Phylogenetic studies can reveal patterns of evolutionary change, including the gain or loss of elaborate courtship traits in males. Male African clawed frogs generally produce complex and rapid courtship vocalizations, whereas female calls are simple and slow. In a few species, however, male vocalizations are also simple and slow, suggesting loss of male-typical traits. Here, we explore features of the male vocal organ that could contribute to loss in two species with simple, slow male calls. In Xenopus boumbaensis, laryngeal morphology is more robust in males than in females. Larynges are larger, have a more complex cartilaginous morphology and contain more muscle fibers. Laryngeal muscle fibers are exclusively fast-twitch in males but are both fast- and slow-twitch in females. The laryngeal electromyogram, a measure of neuromuscular synaptic strength, shows greater potentiation in males than in females. Male-specific physiological features are shared with X. laevis, as well as with a species of the sister clade, Silurana tropicalis, and thus are likely ancestral. In X. borealis, certain aspects of laryngeal morphology and physiology are sexually monomorphic rather than dimorphic. In both sexes, laryngeal muscle fibers are of mixed-twitch type, which limits the production of muscle contractions at rapid intervals. Muscle activity potentiation and discrete tension transients resemble female rather than male X. boumbaensis. The de-masculinization of these laryngeal features suggests an alteration in sensitivity to the gonadal hormones that are known to control the sexual differentiation of the larynx in other Xenopus and Silurana species. PMID:25788725
Native Mass Spectrometry in Fragment-Based Drug Discovery.
Pedro, Liliana; Quinn, Ronald J
2016-07-28
The advent of native mass spectrometry (MS) in 1990 led to the development of new mass spectrometry instrumentation and methodologies for the analysis of noncovalent protein-ligand complexes. Native MS has matured to become a fast, simple, highly sensitive and automatable technique with well-established utility for fragment-based drug discovery (FBDD). Native MS has the capability to directly detect weak ligand binding to proteins, to determine stoichiometry, relative or absolute binding affinities and specificities. Native MS can be used to delineate ligand-binding sites, to elucidate mechanisms of cooperativity and to study the thermodynamics of binding. This review highlights key attributes of native MS for FBDD campaigns.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Attota, Ravikiran, E-mail: Ravikiran.attota@nist.gov; Dixson, Ronald G.
We experimentally demonstrate that the three-dimensional (3-D) shape variations of nanometer-scale objects can be resolved and measured with sub-nanometer scale sensitivity using conventional optical microscopes by analyzing 4-D optical data using the through-focus scanning optical microscopy (TSOM) method. These initial results show that TSOM-determined cross-sectional (3-D) shape differences of 30 nm–40 nm wide lines agree well with critical-dimension atomic force microscope measurements. The TSOM method showed a linewidth uncertainty of 1.22 nm (k = 2). Complex optical simulations are not needed for analysis using the TSOM method, making the process simple, economical, fast, and ideally suited for high volume nanomanufacturing process monitoring.
Advances in Biosensors, Chemosensors and Assays for the Determination of Fusarium Mycotoxins.
Lin, Xialu; Guo, Xiong
2016-05-24
The contaminations of Fusarium mycotoxins in grains and related products, and the exposure in human body are considerable concerns in food safety and human health worldwide. The common Fusarium mycotoxins include fumonisins, T-2 toxin, deoxynivalenol and zearalenone. For this reason, simple, fast and sensitive analytical techniques are particularly important for the screening and determination of Fusarium mycotoxins. In this review, we outlined the related advances in biosensors, chemosensors and assays based on the classical and novel recognition elements such as antibodies, aptamers and molecularly imprinted polymers. Application to food/feed commodities, limit and time of detection were also discussed.
Ozbek, N; Baysal, A
2015-02-01
The new approach for the determination of sulphur in foods was developed, and the sulphur concentrations of various fresh and dried food samples determined using a high-resolution continuum source flame atomic absorption spectrometer with an air/acetylene flame. The proposed method was optimised and the validated using standard reference materials, and certified values were found to be within the 95% confidence interval. The sulphur content of foods ranged from less than the LOD to 1.5mgg(-1). The method is accurate, fast, simple and sensitive. Copyright © 2014 Elsevier Ltd. All rights reserved.
Paquet, Catherine; Daniel, Mark; Knäuper, Bärbel; Gauvin, Lise; Kestens, Yan; Dubé, Laurette
2010-03-01
Local fast-food environments have been increasingly linked to obesity and related outcomes. Individuals who are more sensitive to reward-related cues might be more responsive to such environments. This study aimed to assess the moderating role of sensitivity to reward on the relation between residential fast-food restaurant exposure and fast-food consumption. Four hundred fifteen individuals (49.6% men; mean age: 34.7 y) were sampled from 7 Montreal census tracts stratified by socioeconomic status and French/English language. The frequency of fast-food restaurant visits in the previous week was self-reported. Sensitivity to reward was self-reported by using the Behavioral Activation System (BAS) scale. Fast-food restaurant exposure within 500 m of the participants' residence was determined by using a Geographic Information System. Main and interactive effects of the BAS and fast-food restaurant exposure on fast-food consumption were tested with logistic regression models that accounted for clustering of observations and participants' age, sex, education, and household income. Regression results showed a significant interaction between BAS and fast-food restaurant exposure (P < 0.001). Analysis of BAS tertiles indicated that the association between neighborhood fast-food restaurant exposure and consumption was positive for the highest tertile (odds ratio: 1.49; 95% CI: 1.20, 1.84; P < 0.001) but null for the intermediate (odds ratio: 1.03; 95% CI: 0.80, 1.34; P = 0.81) and lowest (odds ratio: 0.84; 95% CI: 0.51, 1.37; P = 0.49) tertiles. Reward-sensitive individuals may be more responsive to unhealthful cues in their immediate environment.
Obena, Rofeamor P; Lin, Po-Chiao; Lu, Ying-Wei; Li, I-Che; del Mundo, Florian; Arco, Susan dR; Nuesca, Guillermo M; Lin, Chung-Chen; Chen, Yu-Ju
2011-12-15
The significance and epidemiological effects of metals to life necessitate the development of direct, efficient, and rapid method of analysis. Taking advantage of its simple, fast, and high-throughput features, we present a novel approach to metal ion detection by matrix-functionalized magnetic nanoparticle (matrix@MNP)-assisted MALDI-MS. Utilizing 21 biologically and environmentally relevant metal ion solutions, the performance of core and matrix@MNP against conventional matrixes in MALDI-MS and laser desorption ionization (LDI) MS were systemically tested to evaluate the versatility of matrix@MNP as ionization element. The matrix@MNPs provided 20- to >100-fold enhancement on detection sensitivity of metal ions and unambiguous identification through characteristic isotope patterns and accurate mass (<5 ppm), which may be attributed to its multifunctional role as metal chelator, preconcentrator, absorber, and reservoir of energy. Together with the comparison on the ionization behaviors of various metals having different ionization potentials (IP), we formulated a metal ionization mechanism model, alluding to the role of exciton pooling in matrix@MNP-assisted MALDI-MS. Moreover, the detection of Cu in spiked tap water demonstrated the practicability of this new approach as an efficient and direct alternative tool for fast, sensitive, and accurate determination of trace metal ions in real samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang, Kuan-Chung; Chu, Chia-Ho; Hsu, Chen-Pin
In this study, a cost-effective and highly sensitive cholesterol microsensor, which is consisted of cholesterol oxidase (ChOx), horseradish peroxidase (HRP), and polyaniline (PANI), was developed based on the enzyme-induced conductivity change of PANI with fast response. Hydrogen peroxide is produced via the reaction between cholesterol and ChOx, which was immobilized in a dialysis membrane. The produced hydrogen peroxide can oxidize HRP, which can be reduced by oxidizing PANI, thus resulting in decreased conductivity of the polyaniline thin film. The reduced HRP can be oxidized again by hydrogen peroxide and the cycle of the oxidation/reduction continues until all hydrogen peroxide aremore » reacted, leading to the high sensitivity of the sensor due to the signal contributed from all hydrogen peroxide molecules. Cholesterol was detected near the physiological concentrations ranging from 100 mg/dl to 400 mg/dl with the cholesterol microsensors. The results show linear relation between cholesterol concentration and the conductivity change of the PANI. The microsensor showed no response to cholesterol when the PANI was standalone without cholesterol oxidase immobilized, indicating that the enzymatic reaction is required for cholesterol detection. The simple process of the sensor fabrication allows the sensor to be cost-effective and disposable usage. This electronic cholesterol microsensor is promising for point-of-care health monitoring in cholesterol level with low cost and fast response.« less
Gilman, Robert H.; Sanchez-Abanto, Jose R.; Study Group, CRONICAS Cohort
2016-01-01
Objective. To develop and validate a risk score for detecting cases of undiagnosed diabetes in a resource-constrained country. Methods. Two population-based studies in Peruvian population aged ≥35 years were used in the analysis: the ENINBSC survey (n = 2,472) and the CRONICAS Cohort Study (n = 2,945). Fasting plasma glucose ≥7.0 mmol/L was used to diagnose diabetes in both studies. Coefficients for risk score were derived from the ENINBSC data and then the performance was validated using both baseline and follow-up data of the CRONICAS Cohort Study. Results. The prevalence of undiagnosed diabetes was 2.0% in the ENINBSC survey and 2.9% in the CRONICAS Cohort Study. Predictors of undiagnosed diabetes were age, diabetes in first-degree relatives, and waist circumference. Score values ranged from 0 to 4, with an optimal cutoff ≥2 and had a moderate performance when applied in the CRONICAS baseline data (AUC = 0.68; 95% CI: 0.62–0.73; sensitivity 70%; specificity 59%). When predicting incident cases, the AUC was 0.66 (95% CI: 0.61–0.71), with a sensitivity of 69% and specificity of 59%. Conclusions. A simple nonblood based risk score based on age, diabetes in first-degree relatives, and waist circumference can be used as a simple screening tool for undiagnosed and incident cases of diabetes in Peru. PMID:27689096
Current Barriers to Successful Implementation of FIST Principles
2013-07-01
risks will surface during development that could not have been predicted. Managing a thin budget with no schedule slack for these unknown-unknowns is...Fleischer » Keywords: Fast, Inexpensive, Simple, Tiny (FIST); Program Management ; Heuristics; Innovation; Oversight Current Barriers to Successful...Implementation of FIST Principles Capt Brandon Keller, USAF, and Lt Col J. Robert Wirthlin, USAF The Fast, Inexpensive, Simple, and Tiny (FIST
Fast and accurate detection of cancer cell using a versatile three-channel plasmonic sensor
NASA Astrophysics Data System (ADS)
Hoseinian, M.; Ahmadi, A. R.; Bolorizadeh, M. A.
2016-09-01
Surface Plasmon Resonance (SPR) optical fiber sensors can be used as cost-effective small sized biosensors that are relatively simple to operate. Additionally, these instruments are label-free, hence rendering them highly sensitive to biological measurements. In this study, a three-channel microstructure optical fiber plasmonic-based portable biosensor is designed and analyzed using Finite Element Method. The proposed system is capable of determining changes in sample's refractive index with precision of order one thousandth. The biosensor measures three absorption resonance wavelengths of the analytes simultaneously. This property is one of the main advantages of the proposed biosensor since it reduces the error in the measured wavelength and enhances the accuracy of the results up to 10-5 m/RIU by reducing noise. In this paper, Jurkat cell, an indicator cell for leukemia cancer, is considered as the analyte; and its absorption resonance wavelengths as well as sensitivity in each channel are determined.
NASA Astrophysics Data System (ADS)
Hoang, Khoa; Pophristic, Milan; Horan, Andrew J.; Johnston, Murray V.; McEwen, Charles N.
2016-10-01
First results are reported using a simple, fast, and reproducible matrix-assisted ionization (MAI) sample introduction method that provides substantial improvements relative to previously published MAI methods. The sensitivity of the new MAI methods, which requires no laser, high voltage, or nebulizing gas, is comparable to those reported for MALDI-TOF and n-ESI. High resolution full acquisition mass spectra having low chemical background are acquired from low nanoliters of solution using only a few femtomoles of analyte. The limit-of-detection for angiotensin II is less than 50 amol on an Orbitrap Exactive mass spectrometer. Analysis of peptides, including a bovine serum albumin digest, and drugs, including drugs in urine without a purification step, are reported using a 1 μL zero dead volume syringe in which only the analyte solution wetting the walls of the syringe needle is used in the analysis.
Two-question depression-screeners - the solution to all problems?
Albani, Cornelia; Bailer, Harald; Blaser, Gerd; Brähler, Elmar; Geyer, Michael; Grulke, Norbert
2006-04-01
Depression constitutes a considerable issue in medicine and it is anticipated that the amount of people suffering from affective disorders will increase significantly. It would be useful to have a simple, fast screening procedure which would help detect depression. In four recently published articles a two-question depression-screener is recommended. Sensitivity, specificity, likelihood ratios, negative and positive predictive values were compared. For four different clinical samples and one sample that was representative of the German population the prevalence for depression ranged from 6.9 % to 18.1 %. Sensitivity and specificity reached values from 72.6 % to 96.6 % and from 56.9 % to 90.0 % respectively. All negative predictive values were high (< 97 %) opposed to positive predictive values (17.8 % to 38.5 %). Overall, it seems that the two-question screenings are well suited for the exclusion of a major depression. It is possible that regular screening could further lower the percentage of undiagnosed cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azizah, N., E-mail: norazizahparmin84@gmail.com; Gopinath, Subash C. B.; Nadzirah, Sh.
2016-07-06
Titanium dioxide (TiO{sub 2}) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of Scanning Electron Microscopy (SEM) using IDE nanocoated with TiO{sub 2} was studied in this paper. SEM analysis was carried out at 10 kV acceleration volatege and a 9.8 mA emission current to compare IDE with and without TiO{sub 2} on the surface area. The simple fabrication process, high sensitivity, and fast response of the TiO{sub 2} based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO{sub 2} based IDE for sensitive,more » label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.« less
Determination of nitrobenzene in wastewater using a hanging mercury drop electrode.
Liang, Shu-Xuan; Zhang, Huan-Kun; Lu, Da
2007-06-01
The determination of trace amount nitrobenzene in wastewater on a hanging mercury drop electrode was studied. The determination conditions of pH, supporting electrolyte, accumulation potential, accumulation time, and voltammetric response were optimized. The sharp peak of the nitrobenzene was appeared at 0.05 V. The peak electric current was proportional to the concentration of nitrobenzene in the range of 1.47 x 10(-5) approximately 1.0 x 10(-3) mol/l with relative standard deviations of 3.99 approximately 8.94%. The detection limit of the nitrobenzene in water was 5 x 10(-6) mol/l. The proposed method offered low limit of determination, easy operation, the use of simple instrumentation, high sensitivity and good reproducibility. It was applied to the determination of nitrobenzene in wastewater with an average recovery of 94.0% approximately 105%. The proposed method provided fast, sensitive and sometimes real time detection of nitrobenzene.
Sun, Yong-sheng; Lou, Si-quan; Wen, Jian-min; Lv, Wei-xin; Jiao, Chang-geng; Yang, Su-min; Xu, Hai-bin
2011-02-01
To assess the clinical value of polymerase chain reaction (PCR) in the diagnosis and differential diagnosis of joint tuberculosis (TB). PCR was used blindly to detect the DNA of Mycobacterium tuberculosis (M.TB) in five specimens of M.TB, 5 of BCG, and 10 of other bacteria. Then, M. TB in 98 samples from patients with joint TB and 100 samples from patients with non-tubercular joint disorders were detected by PCR, acid-fast staining and culture,. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PCR were calculated. The χ2 test was used for statistical analysis of the frequency of various factors. At the same time, some problems with PCR were also systematically analyzed. (1) In the "standard samples", both M. TB and BCG showed positive while other bacteria were negative. (2) In 98 cases from patients with joint TB, 81 were positive by PCR, 6 by acid-fast staining, and 17 by culture. In 100 cases from patients with non-tuberculous joint disorders, 9 were positive by PCR, and none by either acid-fast staining or culture. Sensitivity, specificity, accuracy, positive and negative predictive value of PCR were 82.65% (81/98), 91.00% (91/100), 86.87% (172/198), 90.00% (81/90) and 84.26% (91/108), respectively. (3) The positive rates for PCR, acid-fast staining and culture in detection of M. TB were 82.65% (81/98), 6.12% (6/98), and 17.34% (17/98), respectively. There were statistically significant differences between the three methods (P < 0.001). (4) The process of PCR is automatic, and can be completed within 3 to 6 hours, whereas 4 to 8 weeks are required for the conventional culture of M. TB. PCR is a sensitive, specific, rapid, simple and minimally invasive method for detection of M. TB in samples from joint TB, and can play an important role in early and rapid diagnosis and differential diagnosis of joint TB. But it also has some limitations, such as false positivity and false negativity. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.
YAHA: fast and flexible long-read alignment with optimal breakpoint detection.
Faust, Gregory G; Hall, Ira M
2012-10-01
With improved short-read assembly algorithms and the recent development of long-read sequencers, split mapping will soon be the preferred method for structural variant (SV) detection. Yet, current alignment tools are not well suited for this. We present YAHA, a fast and flexible hash-based aligner. YAHA is as fast and accurate as BWA-SW at finding the single best alignment per query and is dramatically faster and more sensitive than both SSAHA2 and MegaBLAST at finding all possible alignments. Unlike other aligners that report all, or one, alignment per query, or that use simple heuristics to select alignments, YAHA uses a directed acyclic graph to find the optimal set of alignments that cover a query using a biologically relevant breakpoint penalty. YAHA can also report multiple mappings per defined segment of the query. We show that YAHA detects more breakpoints in less time than BWA-SW across all SV classes, and especially excels at complex SVs comprising multiple breakpoints. YAHA is currently supported on 64-bit Linux systems. Binaries and sample data are freely available for download from http://faculty.virginia.edu/irahall/YAHA. imh4y@virginia.edu.
A ROC-based feature selection method for computer-aided detection and diagnosis
NASA Astrophysics Data System (ADS)
Wang, Songyuan; Zhang, Guopeng; Liao, Qimei; Zhang, Junying; Jiao, Chun; Lu, Hongbing
2014-03-01
Image-based computer-aided detection and diagnosis (CAD) has been a very active research topic aiming to assist physicians to detect lesions and distinguish them from benign to malignant. However, the datasets fed into a classifier usually suffer from small number of samples, as well as significantly less samples available in one class (have a disease) than the other, resulting in the classifier's suboptimal performance. How to identifying the most characterizing features of the observed data for lesion detection is critical to improve the sensitivity and minimize false positives of a CAD system. In this study, we propose a novel feature selection method mR-FAST that combines the minimal-redundancymaximal relevance (mRMR) framework with a selection metric FAST (feature assessment by sliding thresholds) based on the area under a ROC curve (AUC) generated on optimal simple linear discriminants. With three feature datasets extracted from CAD systems for colon polyps and bladder cancer, we show that the space of candidate features selected by mR-FAST is more characterizing for lesion detection with higher AUC, enabling to find a compact subset of superior features at low cost.
Secure FAST: Security Enhancement in the NATO Time Sensitive Targeting Tool
2010-11-01
designed to aid in the tracking and prosecuting of Time Sensitive Targets. The FAST tool provides user level authentication and authorisation in terms...level authentication and authorisation in terms of security. It uses operating system level security but does not provide application level security for...and collaboration tool, designed to aid in the tracking and prosecuting of Time Sensitive Targets. The FAST tool provides user level authentication and
Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L
2015-08-28
Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.
[Differentiation of species within the Mycobacterium tuberculosis complex by molecular techniques].
Herrera-León, Laura; Pozuelo-Díaz, Rodolfo; Molina Moreno, Tamara; Valverde Cobacho, Azucena; Saiz Vega, Pilar; Jiménez Pajares, María Soledad
2009-11-01
The Mycobacterium tuberculosis complex includes the following species: Mycobacterium tuberculosis, Mycobacterium africanum, Mycobacterium bovis, Mycobacterium bovis-BCG, Mycobacterium microti, Mycobacterium caprae, Mycobacterium pinnipedii, and Mycobacterium canettii. These species cause tuberculosis in humans and animals. Identification of mycobacterial strains has classically been performed by phenotype study. Over the last years, laboratories have developed several molecular techniques to differentiate between these species. The aim of this study is to evaluate these methods and develop a simple, fast, identification scheme. We analyzed 251 strains randomly obtained from the strains studied in 2004, and 797 strains received by the Reference Laboratory between 2005 and 2007. Phenotype characterization of 4183 strains isolated during that period was done by studying the colony morphology, characteristics in culture, nitrate reduction, niacin accumulation, and growth in the presence of thiophen-2-carboxylic acid hydrazide 10 microg/mL and pyrazinamide 50 microg/mL. The molecular identification scheme designed was as follows: 1) gyrB PCR-RFLP with RsaI, TaqI or SacII and hsp65 RFLP/PCR with HhaI., and 2) multiplex-PCR to determine the presence/absence of the RD9 and RD1 regions. The results showed 100% agreement between phenotype study and the molecular scheme. This molecular identification scheme is a simple and fast method, with 100% sensitivity and specificity, that can be implemented in most clinical laboratories at a low cost.
Wang, Tong; Wu, Hai-Long; Xie, Li-Xia; Zhu, Li; Liu, Zhi; Sun, Xiao-Dong; Xiao, Rong; Yu, Ru-Qin
2017-04-01
In this work, a smart chemometrics-enhanced strategy, high-performance liquid chromatography, and diode array detection coupled with second-order calibration method based on alternating trilinear decomposition algorithm was proposed to simultaneously quantify 12 polyphenols in different kinds of apple peel and pulp samples. The proposed strategy proved to be a powerful tool to solve the problems of coelution, unknown interferences, and chromatographic shifts in the process of high-performance liquid chromatography analysis, making it possible for the determination of 12 polyphenols in complex apple matrices within 10 min under simple conditions of elution. The average recoveries with standard deviations, and figures of merit including sensitivity, selectivity, limit of detection, and limit of quantitation were calculated to validate the accuracy of the proposed method. Compared to the quantitative analysis results from the classic high-performance liquid chromatography method, the statistical and graphical analysis showed that our proposed strategy obtained more reliable results. All results indicated that our proposed method used in the quantitative analysis of apple polyphenols was an accurate, fast, universal, simple, and green one, and it was expected to be developed as an attractive alternative method for simultaneous determination of multitargeted analytes in complex matrices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Padiolleau, Laurence; Chen, Xi; Jafari, Mohammad Javad; Sheikhzadeh, Elham; Turner, Anthony P. F.; Jager, Edwin W. H.; Beni, Valerio
2016-01-01
Here we demonstrate the use of a functional dopant as a fast and simple way to tune the chemical affinity and selectivity of polypyrrole films. More specifically, a boronic-functionalised dopant, 4-N-Pentylphenylboronic Acid (PBA), was used to provide to polypyrrole films with enhanced affinity towards diols. In order to prove the proposed concept, two model systems were explored: (i) the capture and the electrochemical detection of dopamine and (ii) the adhesion of bacteria onto surfaces. The chemisensor, based on overoxidised polypyrrole boronic doped film, was shown to have the ability to capture and retain dopamine, thus improving its detection; furthermore the chemisensor showed better sensitivity in comparison with overoxidised perchlorate doped films. The adhesion of bacteria, Deinococcus proteolyticus, Escherichia coli, Streptococcus pneumoniae and Klebsiella pneumoniae, onto the boric doped polypyrrole film was also tested. The presence of the boronic group in the polypyrrole film was shown to favour the adhesion of sugar-rich bacterial cells when compared with a control film (Dodecyl benzenesulfonate (DBS) doped film) with similar morphological and physical properties. The presented single step synthesis approach is simple and fast, does not require the development and synthesis of functional monomers, and can be easily expanded to the electrochemical, and possibly chemical, fabrication of novel functional surfaces and interfaces with inherent pre-defined sensing and chemical properties. PMID:27875555
Deng, Chunhui; Li, Ning; Ji, Jie; Yang, Bei; Duan, Gengli; Zhang, Xiangmin
2006-01-01
In this study, a simple, rapid, and sensitive method was developed and validated for the quantification of valproic acid (VPA), an antiepileptic drug, in human plasma, which was based on water-phase derivatization followed by headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS). In the proposed method, VPA in plasma was rapidly derivatized with a mixture of isobutyl chloroformate, ethanol and pyridine under mild conditions (room temperature, aqueous medium), and the VPA ethyl ester formed was headspace-extracted and simultaneously concentrated using the SPME technique. Finally, the analyte extracted on SPME fiber was analyzed by GC/MS. The experimental parameters and method validations were studied. The optimal conditions were obtained: PDMS fiber, stirring rate of 1100 rpm, sample temperature of 80 degrees C, extraction time of 20 min, NaCl concentration of 30%. The proposed method had a limit of quantification (0.3 microg/mL), good recovery (89-97%) and precision (RSD value less than 10%). Because the proposed method combined a rapid water-phase derivatization with a fast, simple and solvent-free sample extraction and concentration technique of SPME, the sample preparation time was less than 25 min. This much shortens the whole analysis time of VPA in plasma. The validated method has been successfully used to analyze VPA in human plasma samples for application in pharmacokinetic studies. All these results show that water-phase derivatization followed by HS-SPME and GC/MS is an alternative and powerful method for fast determination of VPA in biological fluids. Copyright 2006 John Wiley & Sons, Ltd.
Leveque, Nathalie L; Charman, William N; Chiu, Francis C K
2006-01-18
A sensitive, simple and fast liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 1-(4-chlorophenyl)biguanide (4CPB), was developed and validated over a concentration range of 1-2000 ng/mL using only 50 microL of blood or plasma. After a simple solvent precipitation procedure, the supernatant was analysed directly by HPLC-MS/MS. Separation was achieved using an ethyl-linked phenyl reverse phase column with polar endcapping with an acetonitrile-water-formic acid gradient. Mass spectrometry was performed using a triple quadrupole mass spectrometer operating in positive electrospray ionization mode. The elution of PG (254.07-->169.99), CG (252.12-->195.02) and 4CPB (212.06-->153.06) was monitored using selected reaction monitoring. The three compounds and the internal standard (chloroproguanil) were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in blood and plasma. The limit of quantification of PG and CG was 1 ng/mL and 5 ng/mL for 4CPB in rat blood and plasma. The extraction efficiency of PG, CG and 4CPB from rat blood and plasma was higher than 73%. The intra- and inter-assay variability of PG, CG and 4CPB were within 12% and the accuracy within +/-5%. This new assay offers higher sensitivity and a much shorter run time over earlier methods.
Kumaravel, Ammasai; Chandrasekaran, Maruthai
2015-07-15
A rapid and simple method of determination of chlorpyrifos is important in environmental monitoring and quality control. Electrochemical methods for the determination of pesticides are fast, sensitive, reproducible, and cost-effective. The key factor in electrochemical methods is the choice of suitable electrode materials. The electrode materials should have good stability, reproducibility, more sensitivity, and easy method of preparation. Mercury-based electrodes have been widely used for the determination of chlorpyrifos. From an environmental point of view mercury cannot be used. In this study a biocompatible nano-TiO2/cellulose acetate modified glassy carbon electrode was prepared by a simple method and used for the electrochemical sensing of chlorpyrifos in aqueous methanolic solution. Electroanalytical techniques such as cyclic voltammetry, differential pulse voltammetry, and amperometry were used in this work. This electrode showed very good stability, reproducibility, and sensitivity. A well-defined peak was obtained for the reduction of chlorpyrifos in cyclic voltammetry and differential pulse voltammetry. A smooth noise-free current response was obtained in amperometric analysis. The peak current obtained was proportional to the concentration of chlorpyrifos and was used to determine the unknown concentration of chlorpyrifos in the samples. Analytical parameters such as LOD, LOQ, and linear range were estimated. Analysis of real samples was also carried out. The results were validated through HPLC. This composite electrode can be used as an alternative to mercury electrodes reported in the literature.
Gerace, E; Salomone, A; Abbadessa, G; Racca, S; Vincenti, M
2012-02-01
A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid-liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration.
Gerace, E.; Salomone, A.; Abbadessa, G.; Racca, S.; Vincenti, M.
2011-01-01
A fast screening protocol was developed for the simultaneous determination of nine anti-estrogenic agents (aminoglutethimide, anastrozole, clomiphene, drostanolone, formestane, letrozole, mesterolone, tamoxifen, testolactone) plus five of their metabolites in human urine. After an enzymatic hydrolysis, these compounds can be extracted simultaneously from urine with a simple liquid–liquid extraction at alkaline conditions. The analytes were subsequently analyzed by fast-gas chromatography/mass spectrometry (fast-GC/MS) after derivatization. The use of a short column, high-flow carrier gas velocity and fast temperature ramping produced an efficient separation of all analytes in about 4 min, allowing a processing rate of 10 samples/h. The present analytical method was validated according to UNI EN ISO/IEC 17025 guidelines for qualitative methods. The range of investigated parameters included the limit of detection, selectivity, linearity, repeatability, robustness and extraction efficiency. High MS-sampling rate, using a benchtop quadrupole mass analyzer, resulted in accurate peak shape definition under both scan and selected ion monitoring modes, and high sensitivity in the latter mode. Therefore, the performances of the method are comparable to the ones obtainable from traditional GC/MS analysis. The method was successfully tested on real samples arising from clinical treatments of hospitalized patients and could profitably be used for clinical studies on anti-estrogenic drug administration. PMID:29403714
Zhou, Chuan-Hua; Shu, Yun; Hong, Zheng-Yuan; Pang, Dai-Wen; Zhang, Zhi-Ling
2013-09-01
A novel electrochemical magnetoimmunosensor for fast and ultrasensitive detection of H9N2 avian influenza virus particles (H9N2 AIV) was designed based on the combination of high-efficiency immunomagnetic separation, enzyme catalytic amplification, and the biotin-streptavidin system. The reusable, homemade magneto Au electrode (M-AuE) was designed and used for the direct sensing. Immunocomplex-coated magnetic beads (IMBs) were easily accumulated on the surface of the M-AuE to obtain the catalytically reduced electrochemical signal of H2 O2 after the immunoreaction. The transducer was regenerated through a simple washing procedure, which made it possible to detect all the samples on a single electrode with higher reproducibility. The magnetic-bead-based electrochemical immunosensor showed better analytical performance than the planar-electrode-based immunosensor with the same sandwich construction. Amounts as low as 10 pg mL(-1) H9N2 AIV could be detected even in samples of chicken dung. This electrochemical magnetoimmunosensor not only provides a simple platform for the detection of the virus with high sensitivity, selectivity, and reproducibility but also shows great potential in the early diagnosis of diseases. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Targeted Analyte Detection by Standard Addition Improves Detection Limits in MALDI Mass Spectrometry
Eshghi, Shadi Toghi; Li, Xingde; Zhang, Hui
2014-01-01
Matrix-assisted laser desorption/ionization has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications. PMID:22877355
Toghi Eshghi, Shadi; Li, Xingde; Zhang, Hui
2012-09-18
Matrix-assisted laser desorption/ionization (MALDI) has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications.
Zhao, Henry; Pesavento, Lauren; Coote, Skye; Rodrigues, Edrich; Salvaris, Patrick; Smith, Karen; Bernard, Stephen; Stephenson, Michael; Churilov, Leonid; Yassi, Nawaf; Davis, Stephen M; Campbell, Bruce C V
2018-04-01
Clinical triage scales for prehospital recognition of large vessel occlusion (LVO) are limited by low specificity when applied by paramedics. We created the 3-step ambulance clinical triage for acute stroke treatment (ACT-FAST) as the first algorithmic LVO identification tool, designed to improve specificity by recognizing only severe clinical syndromes and optimizing paramedic usability and reliability. The ACT-FAST algorithm consists of (1) unilateral arm drift to stretcher <10 seconds, (2) severe language deficit (if right arm is weak) or gaze deviation/hemineglect assessed by simple shoulder tap test (if left arm is weak), and (3) eligibility and stroke mimic screen. ACT-FAST examination steps were retrospectively validated, and then prospectively validated by paramedics transporting culturally and linguistically diverse patients with suspected stroke in the emergency department, for the identification of internal carotid or proximal middle cerebral artery occlusion. The diagnostic performance of the full ACT-FAST algorithm was then validated for patients accepted for thrombectomy. In retrospective (n=565) and prospective paramedic (n=104) validation, ACT-FAST displayed higher overall accuracy and specificity, when compared with existing LVO triage scales. Agreement of ACT-FAST between paramedics and doctors was excellent (κ=0.91; 95% confidence interval, 0.79-1.0). The full ACT-FAST algorithm (n=60) assessed by paramedics showed high overall accuracy (91.7%), sensitivity (85.7%), specificity (93.5%), and positive predictive value (80%) for recognition of endovascular-eligible LVO. The 3-step ACT-FAST algorithm shows higher specificity and reliability than existing scales for clinical LVO recognition, despite requiring just 2 examination steps. The inclusion of an eligibility step allowed recognition of endovascular-eligible patients with high accuracy. Using a sequential algorithmic approach eliminates scoring confusion and reduces assessment time. Future studies will test whether field application of ACT-FAST by paramedics to bypass suspected patients with LVO directly to endovascular-capable centers can reduce delays to endovascular thrombectomy. © 2018 American Heart Association, Inc.
Wang, Hui; Liu, Tao; Qiu, Quan; Ding, Peng; He, Yan-Hui; Chen, Wei-Qing
2015-01-23
This study aimed to develop and validate a simple risk score for detecting individuals with impaired fasting glucose (IFG) among the Southern Chinese population. A sample of participants aged ≥20 years and without known diabetes from the 2006-2007 Guangzhou diabetes cross-sectional survey was used to develop separate risk scores for men and women. The participants completed a self-administered structured questionnaire and underwent simple clinical measurements. The risk scores were developed by multiple logistic regression analysis. External validation was performed based on three other studies: the 2007 Zhuhai rural population-based study, the 2008-2010 Guangzhou diabetes cross-sectional study and the 2007 Tibet population-based study. Performance of the scores was measured with the Hosmer-Lemeshow goodness-of-fit test and ROC c-statistic. Age, waist circumference, body mass index and family history of diabetes were included in the risk score for both men and women, with the additional factor of hypertension for men. The ROC c-statistic was 0.70 for both men and women in the derivation samples. Risk scores of ≥28 for men and ≥18 for women showed respective sensitivity, specificity, positive predictive value and negative predictive value of 56.6%, 71.7%, 13.0% and 96.0% for men and 68.7%, 60.2%, 11% and 96.0% for women in the derivation population. The scores performed comparably with the Zhuhai rural sample and the 2008-2010 Guangzhou urban samples but poorly in the Tibet sample. The performance of pre-existing USA, Shanghai, and Chengdu risk scores was poorer in our population than in their original study populations. The results suggest that the developed simple IFG risk scores can be generalized in Guangzhou city and nearby rural regions and may help primary health care workers to identify individuals with IFG in their practice.
Wang, Hui; Liu, Tao; Qiu, Quan; Ding, Peng; He, Yan-Hui; Chen, Wei-Qing
2015-01-01
This study aimed to develop and validate a simple risk score for detecting individuals with impaired fasting glucose (IFG) among the Southern Chinese population. A sample of participants aged ≥20 years and without known diabetes from the 2006–2007 Guangzhou diabetes cross-sectional survey was used to develop separate risk scores for men and women. The participants completed a self-administered structured questionnaire and underwent simple clinical measurements. The risk scores were developed by multiple logistic regression analysis. External validation was performed based on three other studies: the 2007 Zhuhai rural population-based study, the 2008–2010 Guangzhou diabetes cross-sectional study and the 2007 Tibet population-based study. Performance of the scores was measured with the Hosmer-Lemeshow goodness-of-fit test and ROC c-statistic. Age, waist circumference, body mass index and family history of diabetes were included in the risk score for both men and women, with the additional factor of hypertension for men. The ROC c-statistic was 0.70 for both men and women in the derivation samples. Risk scores of ≥28 for men and ≥18 for women showed respective sensitivity, specificity, positive predictive value and negative predictive value of 56.6%, 71.7%, 13.0% and 96.0% for men and 68.7%, 60.2%, 11% and 96.0% for women in the derivation population. The scores performed comparably with the Zhuhai rural sample and the 2008–2010 Guangzhou urban samples but poorly in the Tibet sample. The performance of pre-existing USA, Shanghai, and Chengdu risk scores was poorer in our population than in their original study populations. The results suggest that the developed simple IFG risk scores can be generalized in Guangzhou city and nearby rural regions and may help primary health care workers to identify individuals with IFG in their practice. PMID:25625405
Yeom, Se-Hyuk; Kim, Ok-Geun; Kang, Byoung-Ho; Kim, Kyu-Jin; Yuan, Heng; Kwon, Dae-Hyuk; Kim, Hak-Rin; Kang, Shin-Won
2011-11-07
We propose a design for a highly sensitive biosensor based on nanostructured anodized aluminum oxide (AAO) substrates. A gold-deposited AAO substrate exhibits both optical interference and localized surface plasmon resonance (LSPR). In our sensor, application of these disparate optical properties overcomes problems of limited sensitivity, selectivity, and dynamic range seen in similar biosensors. We fabricated uniform periodic nanopore lattice AAO templates by two-step anodizing and assessed their suitability for application in biosensors by characterizing the change in optical response on addition of biomolecules to the AAO template. To determine the suitability of such structures for biosensing applications, we immobilized a layer of C-reactive protein (CRP) antibody on a gold coating atop an AAO template. We then applied a CRP antigen (Ag) atop the immobilized antibody (Ab) layer. The shift in reflectance is interpreted as being caused by the change in refractive index with membrane thickness. Our results confirm that our proposed AAO-based biosensor is highly selective toward detection of CRP antigen, and can measure a change in CRP antigen concentration of 1 fg/ml. This method can provide a simple, fast, and sensitive analysis for protein detection in real-time.
Genuine Onion: Simple, Fast, Flexible, and Cheap Website Authentication
2015-05-21
Genuine onion : Simple, Fast, Flexible, and Cheap Website Authentication Paul Syverson U.S. Naval Research Laboratory paul.syverson@nrl.navy.mil...access to Internet websites. Tor is also used to access sites on the . onion virtual domain. The focus of . onion use and discussion has traditionally... onion system can be used to provide an entirely separate benefit: basic website authentication. We also argue that not only can onionsites provide
Constellation Coverage Analysis
NASA Technical Reports Server (NTRS)
Lo, Martin W. (Compiler)
1997-01-01
The design of satellite constellations requires an understanding of the dynamic global coverage provided by the constellations. Even for a small constellation with a simple circular orbit propagator, the combinatorial nature of the analysis frequently renders the problem intractable. Particularly for the initial design phase where the orbital parameters are still fluid and undetermined, the coverage information is crucial to evaluate the performance of the constellation design. We have developed a fast and simple algorithm for determining the global constellation coverage dynamically using image processing techniques. This approach provides a fast, powerful and simple method for the analysis of global constellation coverage.
Design strategies of fluorescent probes for selective detection among biothiols.
Niu, Li-Ya; Chen, Yu-Zhe; Zheng, Hai-Rong; Wu, Li-Zhu; Tung, Chen-Ho; Yang, Qing-Zheng
2015-10-07
Simple thiol derivatives, such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH), play key roles in biological processes, and the fluorescent probes to detect such thiols in vivo selectively with high sensitivity and fast response times are critical for understanding their numerous functions. However, the similar structures and reactivities of these thiols pose considerable challenges to the development of such probes. This review focuses on various strategies for the design of fluorescent probes for the selective detection of biothiols. We classify the fluorescent probes for discrimination among biothiols according to reaction types between the probes and thiols such as cyclization with aldehydes, conjugate addition-cyclization with acrylates, native chemical ligation, and aromatic substitution-rearrangement.
Sensing interactions in the microworld with optical tweezers
NASA Astrophysics Data System (ADS)
Pacoret, Cécile; Bowman, Richard; Gibson, Graham; Sinan, Haliyo D.; Bergander, Arvid; Carberry, David; Régnier, Stéphane; Padgett, Miles
2009-08-01
Optical Tweezers have become a widespread tool in Cell Biology, microengineering and other fields requiring delicate micromanipulation. But for those sensitive tasks, it remains difficult to handle objects without damaging them. As the precision in position and force measurement increase, the richness of information cannot be fully exploited with simple interfaces such as a mouse or a common joystick. For this reason, we propose a haptic force-feedback optical tweezer command and a force-feedback system controlled by one hand. The system combines accurate force measurement using a fast camera and the coupling of these measured forces with a human operator. The overall transparency allows even the feeling of the Brownian motion.
Villar-Navarro, Mercedes; Martín-Valero, María Jesús; Fernández-Torres, Rut Maria; Callejón-Mochón, Manuel; Bello-López, Miguel Ángel
2017-02-15
An easy and environmental friendly method, based on the use of magnetic molecular imprinted polymers (mag-MIPs) is proposed for the simultaneous extraction of the 16 U.S. EPA polycyclic aromatic hydrocarbons (PAHs) priority pollutants. The mag-MIPs based extraction protocol is simple, more sensitive and low organic solvent consuming compared to official methods and also adequate for those PAHs more retained in the particulate matter. The new proposed extraction method followed by HPLC determination has been validated and applied to different types of water samples: tap water, river water, lake water and mineral water. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Yanping; Zhang, Xin; Zhang, Ling; Jiang, Ke; Cui, Yuanjing; Yang, Yu; Qian, Guodong
2017-11-01
Hydrogen sulfide (H2S) has been commonly viewed as a gas signaling molecule in various physiological and pathological processes. However, the highly efficient H2S detection still remains challenging. Herein, we designed a new robust nano metal-organic framework (MOF) UiO-66-CH=CH2 as a fluorescent probe for rapid, sensitive and selective detection of biological H2S. UiO-66-CH=CH2 was prepared by heating ZrCl4 and 2-vinylterephthalic acid via a simple method. UiO-66-CH=CH2 displayed fluorescence quenching to H2S and kept excellent selectivity in the presence of biological relevant analytes especially the cysteine and glutathione. This MOF-based probe also exhibited fast response (10 s) and high sensitivity with a detection limit of 6.46 μM which was within the concentration range of biological H2S in living system. Moreover, this constructed MOF featured water-stability, nanoscale (20-30 nm) and low toxicity, which made it a promising candidate for biological H2S sensing.
Huh, Junghwan; Park, Jonghyurk; Kim, Gyu Tae; Park, Jeong Young
2011-02-25
We have successfully demonstrated a ZnO nanorod-based 3D nanostructure to show a high sensitivity and very fast response/recovery to hydrogen gas. ZnO nanorods have been synthesized selectively over the pre-defined area at relatively low temperature using a simple self-catalytic solution process assisted by a lithographic method. The conductance of the ZnO nanorod device varies significantly as the concentration of the hydrogen is changed without any additive metal catalyst, revealing a high sensitivity to hydrogen gas. Its superior performance can be explained by the porous structure of its three-dimensional network and the enhanced surface reaction of the hydrogen molecules with the oxygen defects resulting from a high surface-to-volume ratio. It was found that the change of conductance follows a power law depending on the hydrogen concentration. A Langmuir isotherm following an ideal power law and a cross-over behavior of the activation energy with respect to hydrogen concentration were observed. This is a very novel and intriguing phenomenon on nanostructured materials, which suggests competitive surface reactions in ZnO nanorod gas sensors.
Garcia-Fernandez, Juan; Garcia-Molina, Alberto; Aparicio-Lopez, Celeste; Sanchez-Carrion, Rocío; Ensenat, Antònia; Pena-Casanova, Jordi; Roig-Rovira, Teresa
2015-12-16
Tham and Tegner proposed the Baking Tray Task (BTT) as a fast simple assessment test for detecting spatial negligence. However, very few studies have examined its validity as a diagnostic test. To analyse the diagnostic validity of the BTT by measuring its specificity and sensitivity in a sample of subjects with right hemisphere strokes. Forty-eight patients with right hemisphere vascular lesions were distributed in two groups (negligence group, n = 35; non-negligence group, n = 13) according to the scores obtained in a battery of visuospatial examination tests. The participants' performance on the BTT was compared with that of a healthy control group (n = 12). The results showed a high level of sensitivity of the BTT, but low specificity. The performance on the BTT of eight of the 13 members of the non-negligence group was suggestive of negligence. The BTT has proved to be a sensitive test for the detection of spatial negligence. Yet, based on its low specificity, its use alone as a single diagnostic test is not recommended.
Zhang, Fan; Ma, Wei; Jiao, Yang; Wang, Jingchuan; Shan, Xinyan; Li, Hui; Lu, Xinghua; Meng, Sheng
2014-12-24
Adsorption geometry of dye molecules on nanocrystalline TiO2 plays a central role in dye-sensitized solar cells, enabling effective sunlight absorption, fast electron injection, optimized interface band offsets, and stable photovoltaic performance. However, precise determination of dye binding geometry and proportion has been challenging due to complexity and sensitivity at interfaces. Here employing combined vibrational spectrometry and density functional calculations, we identify typical adsorption configurations of widely adopted cyanoacrylic donor-π bridge-acceptor dyes on nanocrystalline TiO2. Binding mode switching from bidentate bridging to hydrogen-bonded monodentate configuration with Ti-N bonding has been observed when dye-sensitizing solution becomes more basic. Raman and infrared spectroscopy measurements confirm this configuration switch and determine quantitatively the proportion of competing binding geometries, with vibration peaks assigned using density functional theory calculations. We further found that the proportion of dye-binding configurations can be manipulated by adjusting pH value of dye-sensitizing solutions. Controlling molecular adsorption density and configurations led to enhanced energy conversion efficiency from 2.4% to 6.1% for the fabricated dye-sensitized solar cells, providing a simple method to improve photovoltaic performance by suppressing unfavorable binding configurations in solar cell applications.
a Facile Synthesis of Fully Porous Tazo Composite and its Remarkable Gas Sensitive Performance
NASA Astrophysics Data System (ADS)
Liang, Dongdong; Liu, Shimin; Wang, Zhinuo; Guo, Yu; Jiang, Weiwei; Liu, Chaoqian; Ding, Wanyu; Wang, Hualin; Wang, Nan; Zhang, Zhihua
The composite of a nanocrystalline SnO2 thick film deposited on an Al-doped ZnO ceramic substrate was firstly proposed. This study also provided a simple, fast and cost effective method to prepare SnO2 thick film and Al-doped ZnO ceramic as well as the final composite. The crystal structure, morphology, composition, pore size distribution and gas sensitivity of the composite were investigated by means of X-ray diffraction, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, Barrett-Joyner-Halenda analysis and gas sensitive measurement system. Results indicated that the composite was fully porous consisted of SnO2, ZnO and ZnAl2O4 crystal phases. The macrosized pores generated in the composite could enhance the gas infiltration into the sensing layers effectively. In this way, combining a high gas-transporting-capability and a nanocrystalline SnO2 thick film, the composite showed very impressive performance. The gas sensitivity of the composite was high enough for ethanol vapor with different concentrations, which was comparable to other kinds of reported SnO2 gas sensors, while showing two straight lines with a turning point at 1000ppm. Finally, the gas sensitive mechanism was proposed based on the microstructure and composition of the composite.
Zuo, Peng; Li, XiuJun; Dominguez, Delfina C; Ye, Bang-Ce
2013-10-07
Infectious pathogens often cause serious public health concerns throughout the world. There is an increasing demand for simple, rapid and sensitive approaches for multiplexed pathogen detection. In this paper we have developed a polydimethylsiloxane (PDMS)/paper/glass hybrid microfluidic system integrated with aptamer-functionalized graphene oxide (GO) nano-biosensors for simple, one-step, multiplexed pathogen detection. The paper substrate used in this hybrid microfluidic system facilitated the integration of aptamer biosensors on the microfluidic biochip, and avoided complicated surface treatment and aptamer probe immobilization in a PDMS or glass-only microfluidic system. Lactobacillus acidophilus was used as a bacterium model to develop the microfluidic platform with a detection limit of 11.0 cfu mL(-1). We have also successfully extended this method to the simultaneous detection of two infectious pathogens - Staphylococcus aureus and Salmonella enterica. This method is simple and fast. The one-step 'turn on' pathogen assay in a ready-to-use microfluidic device only takes ~10 min to complete on the biochip. Furthermore, this microfluidic device has great potential in rapid detection of a wide variety of different other bacterial and viral pathogens.
Zuo, Peng; Dominguez, Delfina C.; Ye, Bang-Ce
2014-01-01
Infectious pathogens often cause serious public health concerns throughout the world. There is an increasing demand for simple, rapid and sensitive approaches for multiplexed pathogen detection. In this paper we have developed a polydimethylsiloxane (PDMS)/paper/glass hybrid microfluidic system integrated with aptamer-functionalized graphene oxide (GO) nano-biosensors for simple, one-step, multiplexed pathogen detection. The paper substrate used in this hybrid microfluidic system facilitated the integration of aptamer biosensors on the microfluidic biochip, and avoided complicated surface treatment and aptamer probe immobilization in a PDMS or glass-only microfluidic system. Lactobacillus acidophilus was used as a bacterium model to develop the microfluidic platform with a detection limit of 11.0 cfu mL−1. We have also successfully extended this method to the simultaneous detection of two infectious pathogens - Staphylococcus aureus and Salmonella enterica. This method is simple and fast. The one-step ‘turn on’ pathogen assay in a ready-to-use microfluidic device only takes ~10 min to complete on the biochip. Furthermore, this microfluidic device has great potential in rapid detection of a wide variety of different other bacterial and viral pathogens. PMID:23929394
A simple rhodamine hydrazide-based turn-on fluorescent probe for HOCl detection.
Zhang, Zhen; Zou, Yuan; Deng, Chengquan; Meng, Liesu
2016-06-01
Hypochlorous acid (HOCl) plays a crucial role in daily life and mediates a variety of physiological processes, however, abnormal levels of HOCl have been associated with numerous human diseases. It is therefore of significant interest to establish a simple, selective, rapid and sensitive fluorogenic method for the detection of HOCl in environmental and biological samples. A hydrazide-containing fluorescent probe based on a rhodamine scaffold was facilely developed that could selectively detect HOCl over other biologically relevant reactive oxygen species, reactive nitrogen species and most common metal ions in vitro. Via an irreversible oxidation-hydrolysis mechanism, and upon HOCl-triggered opening of the intramolecular spirocyclic ring during detection, the rhodamine hydrazide-based probe exhibited large fluorescence enhancement in the emission spectra with a fast response, low detection limit and comparatively wide pH detection range in aqueous media. The probe was further successfully applied to monitoring trace HOCl in tap water and imaging both exogenous and endogenous HOCl within living cells. It is anticipated that this simple and useful probe might be an efficient tool with which to facilitate more HOCl-related chemical and biological research. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
PSOCT studies of intervertebral disk
NASA Astrophysics Data System (ADS)
Matcher, Stephen J.; Winlove, Peter C.; Gangnus, Sergey V.
2004-07-01
Polarization-sensitive optical coherence tomography (PSOCT) is an emerging optical imaging technique that is sensitive to the birefringence properties of tissues. It thus has applications in studying the large-scale ordering of collagen fibers within connective tissues. This ordering not only provides useful insights into the relationship between structure and function for various anatomical structures but also is an indicator of pathology. Intervertebral disk is an elastic tissue of the spine and possesses a 3-D collagen structure well suited to study using PSOCT. Since the outer layer of the disk has a lamellar structure with collagen fibers oriented in a trellis-like arrangement between lamellae, the birefringence fast-axis shows pronounced variations with depth, on a spatial scale of about 100 μm. The lamellar thickness varies with age and possibly with disease. We have used a polarisation-sensitive optical coherence tomography system to measure the birefringence properties of freshly excised, hydrated bovine caudal intervertebral disk and compared this with equine flexor tendon. Our results clearly demonstrate the ability of PSOCT to detect the outer three lamellae, down to a depth of at least 700 μm, via discontinuities in the depth-resolved retardance. We have applied a simple semi-empirical model based on Jones calculus to quantify the variation in the fast-axis orientation with depth. Our data and modeling is in broad agreement with previous studies using x-ray diffraction and polarization microscopy applied to histological sections of dehydrated disk. Our results imply that PSOCT may prove a useful tool to study collagen organisation within intervertebral disk in vitro and possibly in vivo and its variation with age and disease.
Freezer or non-freezer: clinical assessment of freezing of gait.
Snijders, Anke H; Haaxma, Charlotte A; Hagen, Yolien J; Munneke, Marten; Bloem, Bastiaan R
2012-02-01
Freezing of gait (FOG) is both common and debilitating in patients with Parkinson's disease (PD). Future pathophysiology studies will depend critically upon adequate classification of patients as being either 'freezers' or 'non-freezers'. This classification should be based ideally upon objective confirmation by an experienced observer during clinical assessment. Given the known difficulties to elicit FOG when examining patients, we aimed to investigate which simple clinical test would be the most sensitive to provoke FOG objectively. We examined 50 patients with PD, including 32 off-state freezers (defined as experiencing subjective 'gluing of the feet to the floor'). Assessment including a FOG trajectory (three trials: normal speed, fast speed, and with dual tasking) and several turning variants (180° vs. 360° turns; leftward vs. rightward turns; wide vs. narrow turning; and slow vs. fast turns). Sensitivity of the entire assessment to provoke FOG in subjective freezers was 0.74, specificity was 0.94. The most effective test to provoke FOG was rapid 360° turns in both directions and, if negative, combined with a gait trajectory with dual tasking. Repeated testing improved the diagnostic yield. The least informative tests included wide turns, 180° turns or normal speed full turns. Sensitivity to provoke objective FOG in subjective freezers was 0.65 for the rapid full turns in both directions and 0.63 for the FOG trajectory. The most efficient way to objectively ascertain FOG is asking patients to repeatedly make rapid 360° narrow turns from standstill, on the spot and in both directions. Copyright © 2011 Elsevier Ltd. All rights reserved.
... Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering the Menu Ordering Your Meal Eating Fast ... A sandwich or burger from a fast food restaurant can contain more than 100 percent of you ...
Pallapothu, Leela Mohan Kumar; Batta, Neelima; Pigili, Ravi Kumar; Yejella, Rajendra Prasad
2015-02-01
A simple, rapid and sensitive analytical method using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) detection with positive ion electrospray ionization was developed for the determination of dienogest in human K2 EDTA plasma using levonorgestrel d6 as an internal standard (IS). Dienogest and IS were extracted from human plasma using simple liquid-liquid extraction. Chromatographic separation was achieved on a Zorbax XDB-Phenyl column (4.6 × 75 mm, 3.5 µm) under isocratic conditions using acetonitrile-5 mm ammonium acetate (70:30, v/v) at a flow rate of 0.60 mL/min. The protonated precursor to product ion transitions monitored for dienogest and IS were at m/z 312.30 → 135.30 and 319.00 → 251.30, respectively. The method was validated with a linearity range of 1.003-200.896 ng/mL having a total analysis time for each chromatograph of 3.0 min. The method has shown tremendous reproducibility with intra- and inter-day precision (coefficient of variation) <3.97 and 6.10%, respectively, and accuracy within ±4.0% of nominal values. The validated method was applied to a pharmacokinetic study in human plasma samples generated after administration of a single oral dose of 2.0 mg dienogest tablets to healthy female volunteers and was proved to be highly reliable for the analysis of clinical samples. Copyright © 2014 John Wiley & Sons, Ltd.
Microfluidic chip with optical sensor for rapid detection of nerve agent Sarin in water samples
NASA Astrophysics Data System (ADS)
Tan, Hsih Yin; Nguyen, Nam-Trung; Loke, Weng Keong; Tan, Yong Teng
2007-12-01
The chemical warfare agent Sarin is an organophosphate that is highly toxic to humans as they can act as cholinesterase inhibitors, that disrupts neuromuscular transmission. As these nerve agents are colorless, odorless and highly toxic, they can be introduced into drinking water as a means of terrorist sabotage. Hence, numerous innovative devices and methods have been developed for rapid detection of these organophosphates. Microfluidic technology allows the implementation of fast and sensitive detection of Sarin. In this paper, a micro-total analysis systems (TAS), also known as Lab-on-a-chip, fitted with an optical detection system has been developed to analyze the presence of the nerve agent sarin in water samples. In the present set-up, inhibition of co-introduced cholinesterase and water samples containing trace amounts of nerve agent sarin into the microfluidic device was used as the basis for selective detection of sarin. The device was fabricated using polymeric micromachining with PMMA (poly (methymethacrylate)) as the substrate material. A chromophore was utilized to measure the activity of remnant cholinesterase activity, which is inversely related to the amount of sarin present in the water samples. Comparisons were made between two different optical detection techniques and the findings will be presented in this paper. The presented measurement method is simple, fast and as sensitive as Gas Chromatography.
Lugo-Morales, Leyda Z; Loziuk, Philip L; Corder, Amanda K; Toups, J Vincent; Roberts, James G; McCaffrey, Katherine A; Sombers, Leslie A
2013-09-17
Neurotransmission occurs on a millisecond time scale, but conventional methods for monitoring nonelectroactive neurochemicals are limited by slow sampling rates. Despite a significant global market, a sensor capable of measuring the dynamics of rapidly fluctuating, nonelectroactive molecules at a single recording site with high sensitivity, electrochemical selectivity, and a subsecond response time is still lacking. To address this need, we have enabled the real-time detection of dynamic glucose fluctuations in live brain tissue using background-subtracted, fast-scan cyclic voltammetry. The novel microbiosensor consists of a simple carbon fiber surface modified with an electrodeposited chitosan hydrogel encapsulating glucose oxidase. The selectivity afforded by voltammetry enables quantitative and qualitative measurements of enzymatically generated H2O2 without the need for additional strategies to eliminate interfering agents. The microbiosensors possess a sensitivity and limit of detection for glucose of 19.4 ± 0.2 nA mM(-1) and 13.1 ± 0.7 μM, respectively. They are stable, even under deviations from physiological normoxic conditions, and show minimal interference from endogenous electroactive substances. Using this approach, we have quantitatively and selectively monitored pharmacologically evoked glucose fluctuations with unprecedented chemical and spatial resolution. Furthermore, this novel biosensing strategy is widely applicable to the immobilization of any H2O2 producing enzyme, enabling rapid monitoring of many nonelectroactive enzyme substrates.
Tian, Enwei; Liu, Qianqian; Ye, Haoting; Li, Fang; Chao, Zhi
2017-12-18
Background: Wuzhimaotao (the dry root of Ficus hirta ) is used as both medicine and food ingredient by the locals in areas around Nanling Mountains of China. Due to its very similar external morphologies with Duanchangcao (the root of Gelsemium elegans , which contains gelsemine that is extremely neurotoxic) and the associated growth of these two plants, incidents of food poisoning and even death frequently occur, resulting from the misuse of Duanchangcao as Wuzhimaotao. The aim of this study is to develop a fast, even, on-spot approach to identification of Wuzhimaotao. Methods: We used DNA barcode-based recombinase polymerase amplification (BAR-RPA) with species-specific primers targeting the internal transcribed spacer (ITS) region of the rDNA of F. hirta. BAR-RPA reaction time and temperature were optimized and the specificity and sensitivity of BAR-RPA species-specific primers were assessed. Results: This technique showed a high specificity and sensitivity to amplify the genomic DNA of F. hirta and allowed for rapid amplification (within 15 min) of the ITS region under a constant and mild temperature range of 37-42 °C without using thermocyclers. Conclusions: The BAR-RPA assay with a fast DNA extraction protocol provides a simple, energy-saving, and rapid method for identification of Wuzhimaotao in both laboratory and field settings.
Possible metabolic impact of Ramadan fasting in healthy men.
Vardarli, Mustafa Cumhur; Hammes, Hans-Peter; Vardarli, İrfan
2014-01-01
Insulin sensitivity and β-cell function during Ramadan fasting in healthy male subjects have not been investigated so far. We assessed the changes of these and other metabolic parameters to judge the potential metabolic benefits of Ramadan fasting. Twenty-four healthy males of Turkish origin living in Germany, with normal glucose tolerance, participated in this study during Ramadan of 2009; 19 who completed fasting were analyzed. Blood was drawn at sunset after a period of fasting lasting approximately 15 h on days 0, 16, and 30 of Ramadan, as well as 7 and 28 days later. Insulin sensitivity (Homeostasis Model Assessment, HOMA), β-cell function, and other parameters were assessed. Ramadan fasting was associated with a significant reduction (-) or increment (+) for the following variables: insulin sensitivity (-20%; P = 0.04), β-cell function (+10%; P = 0.049), high-density lipoprotein cholesterol (-23%; P = 0.0003), low-density lipoprotein cholesterol (+14%; P = 0.007), nonesterified fatty acids (-62%; P < 0.0001), resistin (-20%; P = 0.01), adiponectin (+16%; P = 0.003), and glucagon (-21%; P = 0.01). C-peptide, insulin, leptin, triglyceride, and very low-density lipoprotein cholesterol concentrations were not significantly changed. Ramadan fasting is associated with transiently impaired insulin sensitivity, compensated for by an increased β-cell function. However, the pattern of insulin resistance-mediating adipocytokines suggests a potentially beneficial metabolic effect of Ramadan fasting.
NASA Astrophysics Data System (ADS)
Fernholz, T.; Teichert, H.; Ebert, V.
A new harmonic detection scheme for fully digital, fast-scanning wavelength-modulation spectroscopy (DFS-WMS) is presented. DFS-WMS is specially suited for in situ absorption measurements in combustion environments under fast fluctuating transmission conditions and is demonstrated for the first time by open-path monitoring of ambient oxygen using a distributed-feedback diode laser, which is doubly modulated with a fast linear 1 kHz-scan and a sinusoidal 300 kHz-modulation. After an analog high-pass filter, the detector signal is digitized with a 5 megasample/s 12-bit AD-converter card plugged into a PC and subsequently - unlike standard lock-ins - filtered further by co-adding 100 scans, to generate a narrowband comb filter. All further filtering and the demodulation are performed completely digitally on a PC with the help of discrete Fourier transforms (DFT). Both 1f- and 2f-signals, are simultaneously extracted from the detector signal using one ADC input channel. For the 2f-signal, a linearity of 2% and a minimum detectable absorption of 10-4 could be verified experimentally, with the sensitivity to date being limited only by insufficient gain on the 2f-frequency channel. Using the offset in the 1f signal as a transmission `probe', we could show that the 2f-signal can be transmission-corrected by a simple division by the 1f-background, proving that DFS-WMS provides the possibility of compensating for transmission fluctuations. With the inherent suppression of additive noise, DFS-WMS seems well suited for quantitative in situ absorption spectroscopy in large combustion systems. This assumption is supported by the first measurements of oxygen in a high-pressure combustor at 12 bar.
... can order a simple blood test , usually done fasting (nothing to eat or drink, except water, for ... screening healthy kids without risk factors, a non-fasting blood test can be used. According to the ...
Oh, Se Yeon
2018-05-01
Aroma is important in night-flowering species, as visually they can not be observed well. Thus, the analysis of the volatiles of evening-primrose is of great interest in biological fields and therapy. Furthermore, the analysis of volatiles demands rapid and simple procedure, because volatiles decompose. The aim of this study is to show the rapid monitoring of the volatiles of evening-primrose according to the flowering or closing by fast gas chromatography/surface acoustic wave GC/SAW. Moreover, calibration according to the sensor temperature of the GC/SAW was performed, achieving a high reproducibility and excellent sensitivity. GC/SAW is an effective analytical method that provides on-line measurements without pretreatment of sample. Headspace solid-phase micro-extraction coupled to gas chromatography mass spectrometry (HS-SPME-GC-MS) and dynamic headspace trapping and extraction with GC-MS were employed to confirm the identification of the volatiles of evening-primrose compared to GC/SAW. Linalool was found to be the dominant component, comprising 96.4-25.2% of the total amount, according to the opening or closing. Interestingly, the amount of indole also varied according to the opening or closing (3.0-0.0%) such as linalool. Also, while the sensitivity increased with the reduction in the sensor temperature of the GC/SAW, the reproducibility showed a tendency to decrease. The results showed that flower opening is related to the volatiles emission, which is pharmacological and plant defensive. GC/SAW can be a useful analytical method for the rapid monitoring of volatiles of evening-primrose according to the opening or closing as it provides second unit analysis, as well as simple, and aroma pattern recognition. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Trends in tungsten coil atomic spectrometry
NASA Astrophysics Data System (ADS)
Donati, George L.
Renewed interest in electrothermal atomic spectrometric methods based on tungsten coil atomizers is a consequence of a world wide increasing demand for fast, inexpensive, sensitive, and portable analytical methods for trace analysis. In this work, tungsten coil atomic absorption spectrometry (WCAAS) and tungsten coil atomic emission spectrometry (WCAES) are used to determine several different metals and even a non-metal at low levels in different samples. Improvements in instrumentation and new strategies to reduce matrix effects and background signals are presented. Investigation of the main factors affecting both WCAAS and WCAES analytical signals points to the importance of a reducing, high temperature gas phase in the processes leading to atomic cloud generation. Some more refractory elements such as V and Ti were determined for the first time by double tungsten coil atomic emission spectrometry (DWCAES). The higher temperatures provided by two atomizers in DWCAES also allowed the detection of Ag, Cu and Sn emission signals for the first time. Simultaneous determination of several elements by WCAES in relatively complex sample matrices was possible after a simple acid extraction. The results show the potential of this method as an alternative to more traditional, expensive methods for fast, more effective analyses and applications in the field. The development of a new metallic atomization cell is also presented. Lower limits of detection in both WCAAS and WCAES determinations were obtained due to factors such as better control of background signal, smaller, more isothermal system, with atomic cloud concentration at the optical path for a longer period of time. Tungsten coil-based methods are especially well suited to applications requiring low sample volume, low cost, sensitivity and portability. Both WCAAS and WCAES have great commercial potential in fields as diverse as archeology and industrial quality control. They are simple, inexpensive, effective methods for trace metal determinations in several different samples, representing an important asset in today's analytical chemistry.
Why fast magnetic reconnection is so prevalent
NASA Astrophysics Data System (ADS)
Boozer, Allen H.
2018-02-01
Evolving magnetic fields are shown to generically reach a state of fast magnetic reconnection in which magnetic field line connections change and magnetic energy is released at an Alfvénic rate. This occurs even in plasmas with zero resistivity; only the finiteness of the mass of the lightest charged particle, an electron, is required. The speed and prevalence of Alfvénic or fast magnetic reconnection imply that its cause must be contained within the ideal evolution equation for magnetic fields, , where is the velocity of the magnetic field lines. For a generic , neighbouring magnetic field lines develop a separation that increases exponentially, as \\unicode[STIX]{x1D70E(\\ell ,t)}$ with the distance along a line. This exponentially enhances the sensitivity of the evolution to non-ideal effects. An analogous effect, the importance of stirring to produce a large-scale flow and enhance mixing, has been recognized by cooks through many millennia, but the importance of the large-scale flow to reconnection is customarily ignored. In part this is due to the sixty-year focus of recognition theory on two-coordinate models, which eliminate the exponential enhancement that is generic with three coordinates. A simple three-coordinate model is developed, which could be used to address many unanswered questions.
Fast parallel tandem mass spectral library searching using GPU hardware acceleration.
Baumgardner, Lydia Ashleigh; Shanmugam, Avinash Kumar; Lam, Henry; Eng, Jimmy K; Martin, Daniel B
2011-06-03
Mass spectrometry-based proteomics is a maturing discipline of biologic research that is experiencing substantial growth. Instrumentation has steadily improved over time with the advent of faster and more sensitive instruments collecting ever larger data files. Consequently, the computational process of matching a peptide fragmentation pattern to its sequence, traditionally accomplished by sequence database searching and more recently also by spectral library searching, has become a bottleneck in many mass spectrometry experiments. In both of these methods, the main rate-limiting step is the comparison of an acquired spectrum with all potential matches from a spectral library or sequence database. This is a highly parallelizable process because the core computational element can be represented as a simple but arithmetically intense multiplication of two vectors. In this paper, we present a proof of concept project taking advantage of the massively parallel computing available on graphics processing units (GPUs) to distribute and accelerate the process of spectral assignment using spectral library searching. This program, which we have named FastPaSS (for Fast Parallelized Spectral Searching), is implemented in CUDA (Compute Unified Device Architecture) from NVIDIA, which allows direct access to the processors in an NVIDIA GPU. Our efforts demonstrate the feasibility of GPU computing for spectral assignment, through implementation of the validated spectral searching algorithm SpectraST in the CUDA environment.
NASA Astrophysics Data System (ADS)
Hameed, M.; Demirel, M. C.; Moradkhani, H.
2015-12-01
Global Sensitivity Analysis (GSA) approach helps identify the effectiveness of model parameters or inputs and thus provides essential information about the model performance. In this study, the effects of the Sacramento Soil Moisture Accounting (SAC-SMA) model parameters, forcing data, and initial conditions are analysed by using two GSA methods: Sobol' and Fourier Amplitude Sensitivity Test (FAST). The simulations are carried out over five sub-basins within the Columbia River Basin (CRB) for three different periods: one-year, four-year, and seven-year. Four factors are considered and evaluated by using the two sensitivity analysis methods: the simulation length, parameter range, model initial conditions, and the reliability of the global sensitivity analysis methods. The reliability of the sensitivity analysis results is compared based on 1) the agreement between the two sensitivity analysis methods (Sobol' and FAST) in terms of highlighting the same parameters or input as the most influential parameters or input and 2) how the methods are cohered in ranking these sensitive parameters under the same conditions (sub-basins and simulation length). The results show the coherence between the Sobol' and FAST sensitivity analysis methods. Additionally, it is found that FAST method is sufficient to evaluate the main effects of the model parameters and inputs. Another conclusion of this study is that the smaller parameter or initial condition ranges, the more consistency and coherence between the sensitivity analysis methods results.
Guan, Zheng; Zhang, Guan-min; Ma, Ping; Liu, Li-hong; Zhou, Tian-yan; Lu, Wei
2010-07-01
In this study, we evaluated the influence of different variance from each of the parameters on the output of tacrolimus population pharmacokinetic (PopPK) model in Chinese healthy volunteers, using Fourier amplitude sensitivity test (FAST). Besides, we estimated the index of sensitivity within whole course of blood sampling, designed different sampling times, and evaluated the quality of parameters' and the efficiency of prediction. It was observed that besides CL1/F, the index of sensitivity for all of the other four parameters (V1/F, V2/F, CL2/F and k(a)) in tacrolimus PopPK model showed relatively high level and changed fast with the time passing. With the increase of the variance of k(a), its indices of sensitivity increased obviously, associated with significant decrease in sensitivity index for the other parameters, and obvious change in peak time as well. According to the simulation of NONMEM and the comparison among different fitting results, we found that the sampling time points designed according to FAST surpassed the other time points. It suggests that FAST can access the sensitivities of model parameters effectively, and assist the design of clinical sampling times and the construction of PopPK model.
Ca2+ current vs. Ca2+ channel cooperativity of exocytosis
Matveev, Victor; Bertram, Richard; Sherman, Arthur
2009-01-01
Recently there has been significant interest and progress in the study of spatio-temporal dynamics of Ca2+ that triggers exocytosis at a fast chemical synapse, which requires understanding the contribution of individual calcium channels to the release of a single vesicle. Experimental protocols provide insight into this question by probing the sensitivity of exocytosis to Ca2+ influx. While varying extracellular or intracellular Ca2+ concentration assesses the intrinsic biochemical Ca2+ cooperativity of neurotransmitter release, varying the number of open Ca2+ channels using pharmacological channel block or the tail current titration probes the cooperativity between individual Ca2+ channels in triggering exocytosis. Despite the wide use of these Ca2+ sensitivity measurements, their interpretation often relies on heuristic arguments. Here we provide a detailed analysis of the Ca2+ sensitivity measures probed by these experimental protocols, present simple expressions for special cases, and demonstrate the distinction between the Ca2+ current cooperativity, defined by the relationship between exocytosis rate and the whole-terminal Ca2+ current magnitude, and the underlying Ca2+ channel cooperativity, defined as the average number of channels involved in the release of a single vesicle. We find simple algebraic expressions that show that the two are different but linearly related. Further, we use 3D computational modeling of buffered Ca2+ diffusion to analyze these distinct Ca2+ cooperativity measures, and demonstrate the role of endogenous Ca2+ buffers on such measures. We show that buffers can either increase or decrease the Ca2+ current cooperativity of exocytosis, depending on their concentration and the single-channel Ca2+ current. PMID:19793978
Khan, Ismail; Iqbal, Zafar; Khan, Abad; Hassan, Muhammad; Nasir, Fazle; Raza, Abida; Ahmad, Lateef; Khan, Amjad; Akhlaq Mughal, Muhammad
2016-10-15
A simple, economical, fast, and sensitive RP-HPLC-UV method has been developed for the simultaneous quantification of Sorafenib and paclitaxel in biological samples and formulations using piroxicam as an internal standard. The experimental conditions were optimized and method was validated according to the standard guidelines. The separation of both the analytes and internal standard was achieved on Discovery HS C18 column (250mm×4.6mm, 5μm) using Acetonitrile and TFA (0.025%) in the ratio of (65:35V/V) as the mobile phase in isocratic mode at a flow rate of 1ml/min, with a wavelength of 245nm and at a column oven temperature of 25°Cin a short run time of 12min. The limits of detection (LLOD) were 5 and 10ng/ml while the limits of quantification (LLOQ) were 10 and 15ng/ml for sorafenib and paclitaxel, respectively. Sorafenib, paclitaxel and piroxicam (IS) were extracted from biological samples by applying acetonitrile as a precipitating and extraction solvent. The method is linear in the range of 15-20,000ng/ml for paclitaxel and 10-5000ng/ml for sorafenib, respectively. The method is sensitive and reliable by considering both of its intra-day and inter-day co-efficient of variance. The method was successfully applied for the quantification of the above mentioned drugs in plasma. The developed method will be applied towards sorafenib and paclitaxel pharmacokinetics studies in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.
Kumar, Subodh; Bansal, Virinder Kumar; Muduly, Dillip Kumar; Sharma, Pawan; Misra, Mahesh C; Chumber, Sunil; Singh, Saraman; Bhardwaj, D N
2015-12-01
Focused assessment with sonography for trauma (FAST) is a limited ultrasound examination, primarily aimed at the identification of the presence of free intraperitoneal or pericardial fluid. In the context of blunt trauma abdomen (BTA), free fluid is usually due to hemorrhage, bowel contents, or both; contributes towards the timely diagnosis of potentially life-threatening hemorrhage; and is a decision-making tool to help determine the need for further evaluation or operative intervention. Fifty patients with blunt trauma abdomen were evaluated prospectively with FAST. The findings of FAST were compared with contrast-enhanced computed tomography (CECT), laparotomy, and autopsy. Any free fluid in the abdomen was presumed to be hemoperitoneum. Sonographic findings of intra-abdominal free fluid were confirmed by CECT, laparotomy, or autopsy wherever indicated. In comparing with CECT scan, FAST had a sensitivity, specificity, and accuracy of 77.27, 100, and 79.16 %, respectively, in the detection of free fluid. When compared with surgical findings, it had a sensitivity, specificity, and accuracy of 94.44, 50, and 90 %, respectively. The sensitivity of FAST was 75 % in determining free fluid in patients who died when compared with autopsy findings. Overall sensitivity, specificity, and accuracy of FAST were 80.43, 75 and 80 %, respectively, for the detection of free fluid in the abdomen. From this study, we can safely conclude that FAST is a rapid, reliable, and feasible investigation in patients with BTA, and it can be performed easily, safely, and quickly in the emergency room with a reasonable sensitivity, specificity, and accuracy. It helps in the initial triage of patients for assessing the need for urgent surgery.
Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves.
Elgendi, Mohamed; Eskofier, Bjoern; Abbott, Derek
2015-07-21
There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG) signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry). The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats). We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design.
Fast particle confinement with optimized coil currents in the W7-X stellarator
NASA Astrophysics Data System (ADS)
Drevlak, M.; Geiger, J.; Helander, P.; Turkin, Y.
2014-07-01
One of the principal goals of the W7-X stellarator is to demonstrate good confinement of energetic ions at finite β. This confinement, however, is sensitive to the magnetic field configuration and is thus vulnerable to design modifications of the coil geometry. The collisionless drift orbit losses for 60 keV protons in W7-X are studied using the ANTS code. Particles in this energy range will be produced by the neutral beam injection (NBI) system being constructed for W7-X, and are particularly important because protons at this energy accurately mimick the behaviour of 3.5 MeV α-particles in a HELIAS reactor. To investigate the possibility of improved fast particle confinement, several approaches to adjust the coil currents (5 main field coil currents +2 auxiliary coil currents) were explored. These strategies include simple rules of thumb as well as computational optimization of various properties of the magnetic field. It is shown that significant improvement of collisionless fast particle confinement can be achieved in W7-X for particle populations similar to α particles produced in fusion reactions. Nevertheless, the experimental goal of demonstrating confinement improvement with rising plasma pressure using an NBI-generated population appears to be difficult based on optimization of the coil currents only. The principal reason for this difficulty is that the NBI deposition profile is broader than the region of good fast-ion confinement around the magnetic axis.
Fernández, Angel L; Varela, Eduardo; Martínez, Lucía; Martínez, Amparo; Sierra, Juan; González-Juanatey, José R; Regueiro, Benito
2010-10-01
With a novel real-time multiplex polymerase chain reaction test, the LightCycler SeptiFast® test, 25 bacterial and fungal species can be identified directly in blood. The SeptiFast® test has been used for rapid etiologic diagnosis in infectious endocarditis using blood samples but has not been evaluated directly on cardiac vegetations in patients being treated for infectious endocarditis. We prospectively analyzed 15 samples of heart valve tissue with active infectious endocarditis using the SeptiFast® test and compared the test's sensitivity with that of blood culture, valve tissue culture, and the SeptiFast® test in blood. The sensitivity of the SeptiFast test in heart valve tissue was 100%. The test results confirmed the diagnosis obtained using blood culture in 13 cases and identified the pathogen in 2 cases where blood culture tested negative. The sensitivity of the SeptiFast® test in heart valve tissue was greater than that obtained with conventional culture of vegetations or with the SeptiFast test in blood.
Zheng, Yongping; Zhang, Tingwei; Wu, Songjie; Zhang, Jue; Fang, Jing
2018-01-01
Molecularly imprinted polymer (MIP) films prepared by bulk polymerization suffer from numerous deficiencies, including poor mass transfer ability and difficulty in controlling reaction rate and film thickness, which usually result in poor repeatability. However, polymer film synthesized by electropolymerization methods benefit from high reproducibility, simplicity and rapidity of preparation. In the present study, an Au film served as the refractive index-sensitive metal film to couple with the light leaked out from optical fiber core and the electrode for electropolymerizing MIP film simultaneously. The manufactured probe exhibited satisfactory sensitivity and specificity. Furthermore, the surface morphology and functional groups of the synthesized MIP film were characterized by Atomic Force Microscopy (AFM) and Fourier transform infrared microspectroscopy (FTIR) for further insights into the adsorption and desorption processes. Given the low cost, label-free test, simple preparation process and fast response, this method has a potential application to monitor substances in complicated real samples for out-of-lab test in the future. PMID:29522472
A fast-response two-photon fluorescent probe for imaging endogenous H2O2 in living cells and tissues
NASA Astrophysics Data System (ADS)
Lu, Yanan; Shi, Xiaomin; Fan, Wenlong; Black, Cory A.; Lu, Zhengliang; Fan, Chunhua
2018-02-01
As a second messenger, hydrogen peroxide plays significant roles in numerous physiological and pathological processes and is related to various diseases including inflammatory disease, diabetes, neurodegenerative disorders, cardiovascular disease and Alzheimer's disease. Two-photon (TP) fluorescent probes reported for the detection of endogenous H2O2 are rare and most have drawbacks such as slow response and low sensitivity. In this report, we demonstrate a simple H2O2-specific TP fluorescent probe (TX-HP) containing a two-photon dye 6-hydroxy-2,3,4,4a-tetrahydro-1H-xanthen-1-one (TX) on the modulation of the ICT process. The probe exhibits a rapid fluorescent response to H2O2 in 9 min with both high sensitivity and selectivity. The probe can detect exogenous H2O2 in living cells. Furthermore, the probe is successfully utilized for imaging H2O2 in liver tissues.
Recording 13C-15N HMQC 2D sparse spectra in solids in 30 s
NASA Astrophysics Data System (ADS)
Kupče, Ēriks; Trébosc, Julien; Perrone, Barbara; Lafon, Olivier; Amoureux, Jean-Paul
2018-03-01
We propose a dipolar HMQC Hadamard-encoded (D-HMQC-Hn) experiment for fast 2D correlations of abundant nuclei in solids. The main limitation of the Hadamard methods resides in the length of the encoding pulses, which results from a compromise between the selectivity and the sensitivity due to losses. For this reason, these methods should mainly be used with sparse spectra, and they profit from the increased separation of the resonances at high magnetic fields. In the case of the D-HMQC-Hn experiments, we give a simple rule that allows directly setting the optimum length of the selective pulses, versus the minimum separation of the resonances in the indirect dimension. The demonstration has been performed on a fully 13C,15N labelled f-MLF sample, and it allowed recording the build-up curves of the 13C-15N cross-peaks within 10 min. However, the method could also be used in the case of less sensitive samples, but with more accumulations.
Caballero, Rodrigo; Huber, Matthew
2013-08-27
Projections of future climate depend critically on refined estimates of climate sensitivity. Recent progress in temperature proxies dramatically increases the magnitude of warming reconstructed from early Paleogene greenhouse climates and demands a close examination of the forcing and feedback mechanisms that maintained this warmth and the broad dynamic range that these paleoclimate records attest to. Here, we show that several complementary resolutions to these questions are possible in the context of model simulations using modern and early Paleogene configurations. We find that (i) changes in boundary conditions representative of slow "Earth system" feedbacks play an important role in maintaining elevated early Paleogene temperatures, (ii) radiative forcing by carbon dioxide deviates significantly from pure logarithmic behavior at concentrations relevant for simulation of the early Paleogene, and (iii) fast or "Charney" climate sensitivity in this model increases sharply as the climate warms. Thus, increased forcing and increased slow and fast sensitivity can all play a substantial role in maintaining early Paleogene warmth. This poses an equifinality problem: The same climate can be maintained by a different mix of these ingredients; however, at present, the mix cannot be constrained directly from climate proxy data. The implications of strongly state-dependent fast sensitivity reach far beyond the early Paleogene. The study of past warm climates may not narrow uncertainty in future climate projections in coming centuries because fast climate sensitivity may itself be state-dependent, but proxies and models are both consistent with significant increases in fast sensitivity with increasing temperature.
De Gaetano, Andrea; Panunzi, Simona; Matone, Alice; Samson, Adeline; Vrbikova, Jana; Bendlova, Bela; Pacini, Giovanni
2013-01-01
In order to provide a method for precise identification of insulin sensitivity from clinical Oral Glucose Tolerance Test (OGTT) observations, a relatively simple mathematical model (Simple Interdependent glucose/insulin MOdel SIMO) for the OGTT, which coherently incorporates commonly accepted physiological assumptions (incretin effect and saturating glucose-driven insulin secretion) has been developed. OGTT data from 78 patients in five different glucose tolerance groups were analyzed: normal glucose tolerance (NGT), impaired glucose tolerance (IGT), impaired fasting glucose (IFG), IFG+IGT, and Type 2 Diabetes Mellitus (T2DM). A comparison with the 2011 Salinari (COntinuos GI tract MOdel, COMO) and the 2002 Dalla Man (Dalla Man MOdel, DMMO) models was made with particular attention to insulin sensitivity indices ISCOMO, ISDMMO and kxgi (the insulin sensitivity index for SIMO). ANOVA on kxgi values across groups resulted significant overall (P<0.001), and post-hoc comparisons highlighted the presence of three different groups: NGT (8.62×10(-5)±9.36×10(-5) min(-1)pM(-1)), IFG (5.30×10(-5)±5.18×10(-5)) and combined IGT, IFG+IGT and T2DM (2.09×10(-5)±1.95×10(-5), 2.38×10(-5)±2.28×10(-5) and 2.38×10(-5)±2.09×10(-5) respectively). No significance was obtained when comparing ISCOMO or ISDMMO across groups. Moreover, kxgi presented the lowest sample average coefficient of variation over the five groups (25.43%), with average CVs for ISCOMO and ISDMMO of 70.32% and 57.75% respectively; kxgi also presented the strongest correlations with all considered empirical measures of insulin sensitivity. While COMO and DMMO appear over-parameterized for fitting single-subject clinical OGTT data, SIMO provides a robust, precise, physiologically plausible estimate of insulin sensitivity, with which habitual empirical insulin sensitivity indices correlate well. The kxgi index, reflecting insulin secretion dependency on glycemia, also significantly differentiates clinically diverse subject groups. The SIMO model may therefore be of value for the quantification of glucose homeostasis from clinical OGTT data.
NASA Astrophysics Data System (ADS)
Cheng, Gang; Wu, Xinghui; Liu, Bing; Li, Bing; Zhang, Xingtang; Du, Zuliang
2011-11-01
ZnO nanowire (NW) ultraviolet (UV) photodetectors have high sensitivity, while the long recovery time is an important limitation for its applications. In this paper, we demonstrate the promising applications of ZnO NW Schottky barrier as high performance UV photodetector with high sensitivity and fast recovery speed. The on/off ratio, sensitivity, and photocurrent gain are 4 × 105, 2.6 × 103 A/W, and 8.5 × 103, respectively. The recovery time is 0.28 s when photocurrent decreases by 3 orders of magnitude, and the corresponding time constant is as short as 46 ms. The physical mechanisms of the fast recovery properties have also been discussed.
Defense.gov Special Report: Send Your Vote Home
, is fast approaching. No matter where you are stationed, registering to vote and getting your absentee ballot is simple, fast and easy. State Guidelines Interactive Map Use the State Guidelines Interactive
Jin, Yang-Hui; Shi, Shi-Yuan; Zheng, Qi; Shen, Jian; Ying, Xiao-Zhang; Wang, Yi-Fan
2017-09-25
To investigate the application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance. The 109 pus specimens were obtained from patients who were primaryly diagnosed as spinal tuberculosis. All of the pus specimens were detected by acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay to definite the differences in sensitivity and specificity of mycobacterium tuberculosis among detecting methods. Pus specimens obtained by different methods were deteceded by MTB/RIF test to analyze the self-influence on Xpert MTB/RIF test. The result of liquid fast culturing by BACTEC MGIT 960 was used as the gold standard; and the value of Xpert MTB/RIF assay in detecting rifampin resistance was analyzed. The sensitivity of acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay were 25.92%, 48.15%, 77.78%, respectively. The sensitivity of pus specimens obtained from open surgery, ultrasound positioning puncture and biopsy the sensitivity were 83.78%, 76.47%, 44.68% respectively deteceded by MTB/RIF test. According to the gold standard of the results of liquid fast culturing by BACTEC MGIT 960 assay, the sensitivity and specificity of Xpert MTB/RIF assay in detecting rifampin resistance were 80%(4/5) and 90.70%(39/43), respectively. Xpert MTB/RIF assay has higher value in diagnosis of spinal tuberculosi, and also can detect rifampin resistance. The number of mycobacterium tuberculosis in pus specimens has a great influence in the sensitivity of Xpert MTB/RIF assay.
Recognition and Sensing of Creatinine.
Guinovart, Tomàs; Hernández-Alonso, Daniel; Adriaenssens, Louis; Blondeau, Pascal; Martínez-Belmonte, Marta; Rius, F Xavier; Andrade, Francisco J; Ballester, Pablo
2016-02-12
Current methods for creatinine quantification suffer from significant drawbacks when aiming to combine accuracy, simplicity, and affordability. Here, an unprecedented synthetic receptor, an aryl-substituted calix[4]pyrrole with a monophosphonate bridge, is reported that displays remarkable affinity for creatinine and the creatininium cation. The receptor works by including the guest in its deep and polar aromatic cavity and establishing directional interactions in three dimensions. When incorporated into a suitable polymeric membrane, this molecule acts as an ionophore. A highly sensitive and selective potentiometric sensor suitable for the determination of creatinine levels in biological fluids, such as urine or plasma, in an accurate, fast, simple, and cost-effective way has thus been developed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Principles and Applications of Liquid Chromatography-Mass Spectrometry in Clinical Biochemistry
Pitt, James J
2009-01-01
Liquid chromatography-mass spectrometry (LC-MS) is now a routine technique with the development of electrospray ionisation (ESI) providing a simple and robust interface. It can be applied to a wide range of biological molecules and the use of tandem MS and stable isotope internal standards allows highly sensitive and accurate assays to be developed although some method optimisation is required to minimise ion suppression effects. Fast scanning speeds allow a high degree of multiplexing and many compounds can be measured in a single analytical run. With the development of more affordable and reliable instruments, LC-MS is starting to play an important role in several areas of clinical biochemistry and compete with conventional liquid chromatography and other techniques such as immunoassay. PMID:19224008
Technical note: use of internal transcribed spacer for ruminal yeast identification in dairy cows.
Vargas-Bello-Pérez, E; Cancino-Padilla, N; Romero, J
2016-12-01
Molecular techniques are important tools for microbiological studies in different habitats, and the internal transcribed spacer (ITS) has been proved to be useful for analyzing fungal diversity. The aim of this study was to use the ITS region to generate ruminal yeast profile and to identify ruminal yeast. DNA from ruminal digesta was extracted to amplify the ribosomal ITS region. The profile from the PCR products was visualized and the excised bands from the profile were identified as the genera Millerozyma, Pichia, Rhizomucor and Hyphopichia. Overall, the ITS resulted to be a simple, fast and sensitive approach that allowed profiling and identification of ruminal yeast that have not been previously described (Millerozyma and Hyphopichia) in the rumen microbial community.
Niu, Kaili; Zheng, Xiaoping; Huang, Chusen; Xul, Kuan; Zhi, Yuan; Shen, Hebai; Jia, Nengqin
2014-07-01
An immunochromatographic test strip using gold nanoparticles-staphylococcus aureus monoclonal antibody conjugates was developed for the rapid and convenient detection of staphylococcus aureus based on a double-antibody sandwich format. The detection limit and the detection rate of this test strip is 10(3) CFU /mL and 98.7%, respectively. It could be used for the rapid detection of staphylococcus aureus in food and the results can be visually identified by the naked eye within 10 min. Compared with conventional bacterial detection methods, this developed immunochromatographic assay based test strip has several advantages including simple, fast, low-cost, favorable sensitivity and specificity, exhibiting a great potential for application in food safety control systems and clinical diagnosis.
Probing the exchange statistics of one-dimensional anyon models
NASA Astrophysics Data System (ADS)
Greschner, Sebastian; Cardarelli, Lorenzo; Santos, Luis
2018-05-01
We propose feasible scenarios for revealing the modified exchange statistics in one-dimensional anyon models in optical lattices based on an extension of the multicolor lattice-depth modulation scheme introduced in [Phys. Rev. A 94, 023615 (2016), 10.1103/PhysRevA.94.023615]. We show that the fast modulation of a two-component fermionic lattice gas in the presence a magnetic field gradient, in combination with additional resonant microwave fields, allows for the quantum simulation of hardcore anyon models with periodic boundary conditions. Such a semisynthetic ring setup allows for realizing an interferometric arrangement sensitive to the anyonic statistics. Moreover, we show as well that simple expansion experiments may reveal the formation of anomalously bound pairs resulting from the anyonic exchange.
Vanlı, Elvan; Mısır, Miraç Nedim; Alp, Hakan; Ak, Tuğba; Özbek, Nurhayat; Ocak, Ümmühan; Ocak, Miraç
2017-09-01
Four fluorescent Schiff bases carrying dipicolylamine groups were designed and synthesized to determine their ion sensor properties in partial aqueous solution. The corresponding amine compound and the aldehyde compounds such as 1-naphthaldehyde, 9-anthraldehyde, phenanthrene-9-carboxaldehyde and 1-pyrenecarboxaldehyde were used to prepare the new Schiff bases. The influence of many metal cations and anions on the spectroscopic properties of the ligands was investigated in ethanol-water (1:1) by means of emission spectrometry. From the spectrofluorimetric titrations, the complexation stoichiometry and complex stability constants of the ligands with Cd 2+ , Zn 2+ , Cu 2+ and Hg 2+ ions were determined. The ligands did not interact with the anions. However, the Schiff base derived from phenanthrene-9-carboxaldehyde showed sensitivity for Cu 2+ among the tested metal ions. The phenanthrene-based Schiff base was used as analytical ligand for the simple and fast determination of Cu 2+ ion in water samples. A modified standard addition method was used to eliminate matrix effect. The linear range was from 0.3 mg/L to 3.8 μg/L. Detection and quantification limits were 0.14 and 0.43 mg/L, respectively. Maximum contaminant level goal (MCLG) for copper in drinking water according to EPA is 1.3 mg/L. The proposed method has high sensitivity to determine copper in drinking waters.
Aflatoxin B1 in eggs and chicken livers by dispersive liquid-liquid microextraction and HPLC.
Amirkhizi, Behzad; Arefhosseini, Seyed Rafie; Ansarin, Masoud; Nemati, Mahboob
2015-01-01
A rapid, low-cost and simple technique has been developed for the determination of aflatoxin B1 (AFB1) in eggs and livers using high-performance liquid chromatography (HPLC) with UV detection. In this study, the presence of AFB1 was investigated in 150 eggs and 50 chicken livers from the local market of Tabriz, Iran. AFB1 was extracted with a mixture of acetonitrile:water (80:20) and cleaned up by dispersive liquid-liquid microextraction which is a very economical, fast and sensitive method. AFB1 was quantified by HPLC-UV without need for any complex derivatisation in samples to enhance the detection. The results showed that 72% of the liver and 58% of the egg samples were contaminated with AFB1 ranging from 0.30 to 16.36 µg kg (̶1). limit of detection and limit of quantification for AFB1 were 0.08 and 0.28 µg kg (̶ 1), respectively. The proposed method is suitable for fast analysing of AFB1 in egg and liver samples.
TDM interrogation of intensity-modulated USFBGs network based on multichannel lasers.
Rohollahnejad, Jalal; Xia, Li; Cheng, Rui; Ran, Yanli; Rahubadde, Udaya; Zhou, Jiaao; Zhu, Lin
2017-01-23
We report a large-scale multi-channel fiber sensing network, where ultra-short FBGs (USFBGs) instead of conventional narrow-band ultra-weak FBGs are used as the sensors. In the time division multiplexing scheme of the network, each grating response is resolved as three adjacent discrete peaks. The central wavelengths of USFBGs are tracked with the differential detection, which is achieved by calculating the peak-to-peak ratio of two maximum peaks. Compared with previous large-scale hybrid multiplexing sensing networks (e.g., WDM/TDM) which typically have relatively low interrogation speed and very high complexity, the proposed system can achieve interrogation of all channel sensors through very fast and simple intensity measurements with a broad dynamic range. A proof-of-concept experiment with twenty USFBGs, at two wavelength channels, was performed and a fast static strain measurements were demonstrated, with a high average sensitivity of ~0.54dB/µƐ and wide dynamic range of over ~3000µƐ. The channel to channel switching time was 10ms and total network interrogation time was 50ms.
Fast-Response Turn-on Fluorescent Probes Based on Thiolysis of NBD Amine for H2 S Bioimaging.
Wang, Runyu; Li, Zhifei; Zhang, Changyu; Li, Yanyan; Xu, Guoce; Zhang, Qiang-Zhe; Li, Lu-Yuan; Yi, Long; Xi, Zhen
2016-05-17
Hydrogen sulfide (H2 S) is an important endogenous signaling molecule with multiple biological functions. New selective fluorescent turn-on probes based on fast thiolyling of NBD (7-nitro-1,2,3-benzoxadiazole) amine were explored for sensing H2 S in aqueous buffer and in living cells. The syntheses of both probes are simple and quite straightforward. The probes are highly sensitive and selective toward H2 S over other biologically relevant species. The fluorescein-NBD-based probe showed 65-fold green fluorescent increase upon H2 S activation. The rhodamine-NBD-based probe reacted rapidly with H2 S (t1/2 ≈1 min) to give a 4.5-fold increase in red fluorescence. Moreover, both probes were successfully used for monitoring H2 S in living cells and in mice. Based on such probe-based tools, we could observe H2 O2 -induced H2 S biogenesis in a concentration-dependent and time-dependent fashion in living cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A LYSO crystal array readout by silicon photomultipliers as compact detector for space applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kryemadhi, A.; Barner, L.; Grove, A.
Precise measurements of GeV range gamma rays help narrow down among var- ious gamma emission models and increase sensitivity for dark matter searches. Construction of precise as well as compact instruments requires detectors with high efficiency, high stopping power, excellent energy resolution, and excellent angular resolution. Fast and bright crystal scintillators coupled with small foot- print photo-detectors are suitable candidates. We prototyped a detector array consisting of four LYSO crystals where each crystal is read out by a 2x2 SensL ArrayJ60035 silicon photomultipliers. The LYSO crystals were chosen because of their good light yield, fast decay time, demonstrated radiation hardness,more » and small radiation length. Here, we used the silicon photomultiplier arrays as photo- detectors because of their small size, simple readout, low voltage operation, and immunity to magnetic elds. We also studied the detector performance in the energy range of interest by exposing it to 2-16 GeV particles produced at the Test Beam Facility of Fermi National Accelerator Laboratory.« less
Chen, Limei; Li, Haijuan; He, Haili; Wu, Haoxi; Jin, Yongdong
2015-07-07
Fast and accurate identification of cancer cells from healthy normal cells in a simple, generic way is very crucial for early cancer detection and treatment. Although functional nanoparticles, like fluorescent quantum dots and plasmonic Au nanoparticles (NPs), have been successfully applied for cancer cell imaging and photothermal therapy, they suffer from the main drawback of needing time-consuming targeting preparation for specific cancer cell detection and selective ablation. The lack of a generic and effective method therefore limits their potential high-throughput cancer cell preliminary screening and theranostic applications. We report herein a generic in vitro method for fast, targeting-free (avoiding time-consuming preparations of targeting moiety for specific cancer cells) visual screening and selective killing of cancer cells from normal cells, by using glucose-responsive/-sensitive glucose oxidase-modified Ag/Au nanoshells (Ag/Au-GOx NSs) as a smart plasmonic theranostic agent. The method is generic to some extent since it is based on the distinct localized surface plasmon resonance (LSPR) responses (and colors) of the smart nanoprobe with cancer cells (typically have a higher glucose uptake level) and normal cells.
Fast Readout Architectures for Large Arrays of Digital Pixels: Examples and Applications
Gabrielli, A.
2014-01-01
Modern pixel detectors, particularly those designed and constructed for applications and experiments for high-energy physics, are commonly built implementing general readout architectures, not specifically optimized in terms of speed. High-energy physics experiments use bidimensional matrices of sensitive elements located on a silicon die. Sensors are read out via other integrated circuits bump bonded over the sensor dies. The speed of the readout electronics can significantly increase the overall performance of the system, and so here novel forms of readout architectures are studied and described. These circuits have been investigated in terms of speed and are particularly suited for large monolithic, low-pitch pixel detectors. The idea is to have a small simple structure that may be expanded to fit large matrices without affecting the layout complexity of the chip, while maintaining a reasonably high readout speed. The solutions might be applied to devices for applications not only in physics but also to general-purpose pixel detectors whenever online fast data sparsification is required. The paper presents also simulations on the efficiencies of the systems as proof of concept for the proposed ideas. PMID:24778588
A LYSO crystal array readout by silicon photomultipliers as compact detector for space applications
Kryemadhi, A.; Barner, L.; Grove, A.; ...
2017-10-31
Precise measurements of GeV range gamma rays help narrow down among var- ious gamma emission models and increase sensitivity for dark matter searches. Construction of precise as well as compact instruments requires detectors with high efficiency, high stopping power, excellent energy resolution, and excellent angular resolution. Fast and bright crystal scintillators coupled with small foot- print photo-detectors are suitable candidates. We prototyped a detector array consisting of four LYSO crystals where each crystal is read out by a 2x2 SensL ArrayJ60035 silicon photomultipliers. The LYSO crystals were chosen because of their good light yield, fast decay time, demonstrated radiation hardness,more » and small radiation length. Here, we used the silicon photomultiplier arrays as photo- detectors because of their small size, simple readout, low voltage operation, and immunity to magnetic elds. We also studied the detector performance in the energy range of interest by exposing it to 2-16 GeV particles produced at the Test Beam Facility of Fermi National Accelerator Laboratory.« less
NASA Astrophysics Data System (ADS)
Alizadeh, A.; Khodaei, M. M.; Karami, Ch; Workentin, M. S.; Shamsipur, M.; Sadeghi, M.
2010-08-01
A gold nanoparticle (AuNPs)-based simple and fast colorimetric sensor for selective detecting of Pb(II) in aqueous solution has been developed. Monodisperse AuNPs (approx. 2.0 nm diameter) has been prepared facilely and further modified with an alkanethiol-bearing monoazacrown ether terminus. These AuNPs are shown to selectively sense Pb2 + through color change, which is visually discernible by an appearance of the surface plasmon band (SPB) at 520 nm. The recognition mechanism is attributed to the unique structure of the monoazacrown ether attached to AuNPs and metal sandwich coordination between two azacrown ether moieties that are attached to separate nanoparticles. This inter-particle cross-linking results in an aggregation and apparent color change from brown to purple. Additionally, TEM experiments support the optical absorption data proving the aggregation between azacrown ether-capped gold nanoparticles. This AuNP-based colorimetric assay is a facile and robust method and allows fast detection of Pb2 + at ambient temperatures. More importantly, the developed technique does not utilize enzymatic reactions, light-sensitive dye molecules, lengthy protocols or sophisticated instrumentation.
NASA Astrophysics Data System (ADS)
Wu, Mianmian; Li, Pan; Zhu, Qingxia; Wu, Meiran; Li, Hao; Lu, Feng
2018-05-01
There has been an increasing demand for rapid and sensitive techniques for the identification of Sudan compounds that emerged as the most often illegally added fat-soluble dyes in herbal medicine. In this report, we have designed and fabricated a functionalized filter paper consisting of gold nanorods (GNRs) and mono-6-thio-cyclodextrin (HS-β-CD) as a surface-enhanced Raman spectroscopy (SERS) substrate, in which the GNR provides sufficient SERS enhancement, and the HS-β-CD with strong chemical affinity toward GNR provides the inclusion compound to capture hydrophobic molecules. Moreover, the CD-GNR were uniformly assembled on filter paper cellulose through the electrostatic adsorption and hydrogen bond, so that the CD-GNR paper-based SERS substrate (CD-GNR-paper) demonstrated higher sensitivity for the determination of Sudan III (0.1 μM) and Sudan IV (0.5 μM) than GNRs paper-based SERS substrate (GNR-paper), with high stability after the storage in the open air for 90 days. Importantly, CD-GNR-paper can effectively collect the Sudan dyes from illegally adulterated onto samples of Resina Draconis with a simple operation, further open up new exciting opportunity for SERS detection of more compounds illegally added with high sensitivity and fast signal responses.
Nguyen, Van Toan; Nguyen, Viet Chien; Nguyen, Van Duy; Hoang, Si Hong; Hugo, Nguyen; Nguyen, Duc Hoa; Nguyen, Van Hieu
2016-01-15
Ultrasensitive and selective hydrogen gas sensor is vital component in safe use of hydrogen that requires a detection and alarm of leakage. Herein, we fabricated a H2 sensing devices by adopting a simple design of planar-type structure sensor in which the heater, electrode, and sensing layer were patterned on the front side of a silicon wafer. The SnO2 thin film-based sensors that were sensitized with microsized Pd islands were fabricated at a wafer-scale by using a sputtering system combined with micro-electronic techniques. The thicknesses of SnO2 thin film and microsized Pd islands were optimized to maximize the sensing performance of the devices. The optimized sensor could be used for monitoring hydrogen gas at low concentrations of 25-250 ppm, with a linear dependence to H2 concentration and a fast response and recovery time. The sensor also showed excellent selectivity for monitoring H2 among other gases, such as CO, NH3, and LPG, and satisfactory characteristics for ensuring safety in handling hydrogen. The hydrogen sensing characteristics of the sensors sensitized with Pt and Au islands were also studied to clarify the sensing mechanisms. Copyright © 2015 Elsevier B.V. All rights reserved.
Krõlov, Katrin; Frolova, Jekaterina; Tudoran, Oana; Suhorutsenko, Julia; Lehto, Taavi; Sibul, Hiljar; Mäger, Imre; Laanpere, Made; Tulp, Indrek; Langel, Ülo
2014-01-01
Chlamydia trachomatis is the most common sexually transmitted human pathogen. Infection results in minimal to no symptoms in approximately two-thirds of women and therefore often goes undiagnosed. C. trachomatis infections are a major public health concern because of the potential severe long-term consequences, including an increased risk of ectopic pregnancy, chronic pelvic pain, and infertility. To date, several point-of-care tests have been developed for C. trachomatis diagnostics. Although many of them are fast and specific, they lack the required sensitivity for large-scale application. We describe a rapid and sensitive form of detection directly from urine samples. The assay uses recombinase polymerase amplification and has a minimum detection limit of 5 to 12 pathogens per test. Furthermore, it enables detection within 20 minutes directly from urine samples without DNA purification before the amplification reaction. Initial analysis of the assay from clinical patient samples had a specificity of 100% (95% CI, 92%-100%) and a sensitivity of 83% (95% CI, 51%-97%). The whole procedure is fairly simple and does not require specific machinery, making it potentially applicable in point-of-care settings. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Zhang, Jinhai; Feng, Youjun; Hu, Dan; Lv, Heng; Zhu, Jing; Cao, Min; Zheng, Feng; Zhu, Jin; Gong, Xiufang; Hao, Lina; Srinivas, Swaminath; Ren, Hao; Qi, Zhongtian
2013-01-01
An epidemic of human H7N9 influenza virus infection recently emerged in China whose clinical features include high mortality and which has also resulted in serious economic loss. The novel reassortant avian-origin influenza A (H7N9) virus which was the causative agent of this epidemic raised the possibility of triggering a large-scale influenza pandemic worldwide. It seemed likely that fast molecular detection assays specific for this virus would be in great demand. Here, we report a one-step reverse transcription–loop-mediated isothermal amplification (RT-LAMP) method for rapid detection of the hemagglutinin (HA) and neuraminidase (NA) genes of H7N9 virus, the minimum detection limit of which was evaluated using in vitro RNA transcription templates. In total, 135 samples from clinical specimens (from either patients or poultry) were tested using this method in comparison with the real-time PCR recommended by the World Health Organization (WHO). Our results showed that (i) RT-LAMP-based trials can be completed in approximately 12 to 23 min and (ii) the detection limit for the H7 gene is around 10 copies per reaction, similar to that of the real-time PCR, whereas the detection limit for its counterpart the N9 gene is 5 copies per reaction, a 100-fold-higher sensitivity than the WHO-recommended method. Indeed, this excellent performance of our method was also validated by the results for a series of clinical specimens. Therefore, we believe that the simple, fast, and sensitive method of RT-LAMP might be widely applied for detection of H7N9 infections and may play a role in prevention of an influenza pandemic. PMID:24006004
Service, Elisabet; Maury, Sini
2015-01-01
Working memory (WM) has been described as an interface between cognition and action, or a system for access to a limited amount of information needed in complex cognition. Access to morphological information is needed for comprehending and producing sentences. The present study probed WM for morphologically complex word forms in Finnish, a morphologically rich language. We studied monomorphemic (boy), inflected (boy+’s), and derived (boy+hood) words in three tasks. Simple span, immediate serial recall of words, in Experiment 1, is assumed to mainly rely on information in the focus of attention. Sentence span, a dual task combining sentence reading with recall of the last word (Experiment 2) or of a word not included in the sentence (Experiment 3) is assumed to involve establishment of a search set in long-term memory for fast activation into the focus of attention. Recall was best for monomorphemic and worst for inflected word forms with performance on derived words in between. However, there was an interaction between word type and experiment, suggesting that complex span is more sensitive to morphological complexity in derivations than simple span. This was explored in a within-subjects Experiment 4 combining all three tasks. An interaction between morphological complexity and task was replicated. Both inflected and derived forms increased load in WM. In simple span, recall of inflectional forms resulted in form errors. Complex span tasks were more sensitive to morphological load in derived words, possibly resulting from interference from morphological neighbors in the mental lexicon. The results are best understood as involving competition among inflectional forms when binding words from input into an output structure, and competition from morphological neighbors in secondary memory during cumulative retrieval-encoding cycles. Models of verbal recall need to be able to represent morphological as well as phonological and semantic information. PMID:25642181
Low-Resolution Vision-at the Hub of Eye Evolution.
Nilsson, Dan-E; Bok, Michael J
2017-11-01
Simple roles for photoreception are likely to have preceded more demanding ones such as vision. The driving force behind this evolution is the improvement and elaboration of animal behaviors using photoreceptor input. Because the basic role for all senses aimed at the external world is to guide behavior, we argue here that understanding this "behavioral drive" is essential for unraveling the evolutionary past of the senses. Photoreception serves many different types of behavior, from simple shadow responses to visual communication. Based on minimum performance requirements for different types of tasks, photoreceptors have been argued to have evolved from non-directional receptors, via directional receptors, to low-resolution vision, and finally to high-resolution vision. Through this sequence, the performance requirements on the photoreceptors have gradually changed from broad to narrow angular sensitivity, from slow to fast response, and from low to high contrast sensitivity during the evolution from simple to more advanced and demanding behaviors. New behaviors would only evolve if their sensory performance requirements to some degree overlap with the requirements of already existing behaviors. This need for sensory "performance continuity" must have determined the order by which behaviors have evolved and thus been an important factor guiding animal evolution. Naturally, new behaviors are most likely to evolve from already existing behaviors with similar neural processing needs and similar motor responses, pointing to "neural continuity" as another guiding factor in sensory evolution. Here we use these principles to derive an evolutionary tree for behaviors driven by photoreceptor input. © The Author 2017. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Wide dynamic logarithmic InGaAs sensor suitable for eye-safe active imaging
NASA Astrophysics Data System (ADS)
Ni, Yang; Bouvier, Christian; Arion, Bogdan; Noguier, Vincent
2016-05-01
In this paper, we present a simple method to analyze the injection efficiency of the photodiode interface circuit under fast shuttering conditions for active Imaging applications. This simple model has been inspired from the companion model for reactive elements largely used in CAD. In this paper, we demonstrate that traditional CTIA photodiode interface is not adequate for active imaging where fast and precise shuttering operation is necessary. Afterwards we present a direct amplification based photodiode interface which can provide an accurate and fast shuttering operation on photodiode. These considerations have been used in NIT's newly developed ROIC and corresponding SWIR sensors both in VGA 15um pitch (NSC1201) and also in QVGA 25um pitch (NSC1401).
NASA Astrophysics Data System (ADS)
Azizah, N.; Hashim, U.; Arshad, M. K. Md.; Gopinath, Subash C. B.; Nadzirah, Sh.; Farehanim, M. A.; Fatin, M. F.; Ruslinda, A. R.; Ayub, R. M.
2016-07-01
Titanium dioxide (TiO2) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO2 was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to an acid solution. Amine and oxide functionalized TiO2 based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO2 based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO2 based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.
Shaibani, Parmiss Mojir; Etayash, Hashem; Naicker, Selvaraj; Kaur, Kamaljit; Thundat, Thomas
2017-01-27
We report a simple, fast, and cost-effective approach that measures cancer cell metabolism and their response to anticancer drugs in real time. Using a Light Addressable Potentiometric Sensor integrated with pH sensitive hydrogel nanofibers (NF-LAPS), we detect localized changes in pH of the media as cancer cells consume glucose and release lactate. NF-LAPS shows a sensitivity response of 74 mV/pH for cancer cells. Cancer cells (MDA MB231) showed a response of ∼0.4 unit change in pH compared to virtually no change observed for normal cells (MCF10A). We also observed a drop in pH for the multidrug-resistant cancer cells (MDA-MB-435MDR) in the presence of doxorubicin. However, inhibition of the metabolic enzymes such as hexokinase and lactate dehydrogenase-A suggested an improvement in the efficacy of doxorubicin by decreasing the level of acidification. This approach, based on extracellular acidification, enhances our understanding of cancer cell metabolic modes and their response to chemotherapies, which will help in the development of better treatments, including choice of drugs and dosages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azizah, N., E-mail: norazizahparmin84@gmail.com; Gopinath, Subash C. B.; Nadzirah, Sh.
Titanium dioxide (TiO{sub 2}) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO{sub 2} was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to anmore » acid solution. Amine and oxide functionalized TiO{sub 2} based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO{sub 2} based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO{sub 2} based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.« less
Tao, Chenyu; Zhang, Qingde; Feng, Na; Shi, Deshi; Liu, Bang
2016-03-01
The qualitative and quantitative declaration of food ingredients is important to consumers, especially for genetically modified food as it experiences a rapid increase in sales. In this study, we designed an accurate and rapid detection system using colloidal gold immunochromatographic strip assay (GICA) methods to detect genetically modified cow milk. First, we prepared 2 monoclonal antibodies for human α-lactalbumin (α-LA) and measured their antibody titers; the one with the higher titer was used for further experiments. Then, we found the optimal pH value and protein amount of GICA for detection of pure milk samples. The developed strips successfully detected genetically modified cow milk and non-modified cow milk. To determine the sensitivity of GICA, a quantitative ELISA system was used to determine the exact amount of α-LA, and then genetically modified milk was diluted at different rates to test the sensitivity of GICA; the sensitivity was 10 μg/mL. Our results demonstrated that the applied method was effective to detect human α-LA in cow milk. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Tee-ngam, Prinjaporn; Nunant, Namthip; Rattanarat, Poomrat; Siangproh, Weena; Chailapakul, Orawon
2013-01-01
Ferulic acid is an important phenolic antioxidant found in or added to diet supplements, beverages, and cosmetic creams. Two designs of paper-based platforms for the fast, simple and inexpensive evaluation of ferulic acid contents in food and pharmaceutical cosmetics were evaluated. The first, a paper-based electrochemical device, was developed for ferulic acid detection in uncomplicated matrix samples and was created by the photolithographic method. The second, a paper-based colorimetric device was preceded by thin layer chromatography (TLC) for the separation and detection of ferulic acid in complex samples using a silica plate stationary phase and an 85:15:1 (v/v/v) chloroform: methanol: formic acid mobile phase. After separation, ferulic acid containing section of the TLC plate was attached onto the patterned paper containing the colorimetric reagent and eluted with ethanol. The resulting color change was photographed and quantitatively converted to intensity. Under the optimal conditions, the limit of detection of ferulic acid was found to be 1 ppm and 7 ppm (S/N = 3) for first and second designs, respectively, with good agreement with the standard HPLC-UV detection method. Therefore, these methods can be used for the simple, rapid, inexpensive and sensitive quantification of ferulic acid in a variety of samples. PMID:24077320
NASA Astrophysics Data System (ADS)
Song, Seok-Jeong; Kim, Tae-Il; Kim, Youngmi; Nam, Hyoungsik
2018-05-01
Recently, a simple, sensitive, and low-cost fluorescent indicator has been proposed to determine water contents in organic solvents, drugs, and foodstuffs. The change of water content leads to the change of the indicator's fluorescence color under the ultra-violet (UV) light. Whereas the water content values could be estimated from the spectrum obtained by a bulky and expensive spectrometer in the previous research, this paper demonstrates a simple and low-cost camera-based water content measurement scheme with the same fluorescent water indicator. Water content is calculated over the range of 0-30% by quadratic polynomial regression models with color information extracted from the captured images of samples. Especially, several color spaces such as RGB, xyY, L∗a∗b∗, u‧v‧, HSV, and YCBCR have been investigated to establish the optimal color information features over both linear and nonlinear RGB data given by a camera before and after gamma correction. In the end, a 2nd order polynomial regression model along with HSV in a linear domain achieves the minimum mean square error of 1.06% for a 3-fold cross validation method. Additionally, the resultant water content estimation model is implemented and evaluated in an off-the-shelf Android-based smartphone.
Caballero, Rodrigo; Huber, Matthew
2013-01-01
Projections of future climate depend critically on refined estimates of climate sensitivity. Recent progress in temperature proxies dramatically increases the magnitude of warming reconstructed from early Paleogene greenhouse climates and demands a close examination of the forcing and feedback mechanisms that maintained this warmth and the broad dynamic range that these paleoclimate records attest to. Here, we show that several complementary resolutions to these questions are possible in the context of model simulations using modern and early Paleogene configurations. We find that (i) changes in boundary conditions representative of slow “Earth system” feedbacks play an important role in maintaining elevated early Paleogene temperatures, (ii) radiative forcing by carbon dioxide deviates significantly from pure logarithmic behavior at concentrations relevant for simulation of the early Paleogene, and (iii) fast or “Charney” climate sensitivity in this model increases sharply as the climate warms. Thus, increased forcing and increased slow and fast sensitivity can all play a substantial role in maintaining early Paleogene warmth. This poses an equifinality problem: The same climate can be maintained by a different mix of these ingredients; however, at present, the mix cannot be constrained directly from climate proxy data. The implications of strongly state-dependent fast sensitivity reach far beyond the early Paleogene. The study of past warm climates may not narrow uncertainty in future climate projections in coming centuries because fast climate sensitivity may itself be state-dependent, but proxies and models are both consistent with significant increases in fast sensitivity with increasing temperature. PMID:23918397
mrsFAST-Ultra: a compact, SNP-aware mapper for high performance sequencing applications.
Hach, Faraz; Sarrafi, Iman; Hormozdiari, Farhad; Alkan, Can; Eichler, Evan E; Sahinalp, S Cenk
2014-07-01
High throughput sequencing (HTS) platforms generate unprecedented amounts of data that introduce challenges for processing and downstream analysis. While tools that report the 'best' mapping location of each read provide a fast way to process HTS data, they are not suitable for many types of downstream analysis such as structural variation detection, where it is important to report multiple mapping loci for each read. For this purpose we introduce mrsFAST-Ultra, a fast, cache oblivious, SNP-aware aligner that can handle the multi-mapping of HTS reads very efficiently. mrsFAST-Ultra improves mrsFAST, our first cache oblivious read aligner capable of handling multi-mapping reads, through new and compact index structures that reduce not only the overall memory usage but also the number of CPU operations per alignment. In fact the size of the index generated by mrsFAST-Ultra is 10 times smaller than that of mrsFAST. As importantly, mrsFAST-Ultra introduces new features such as being able to (i) obtain the best mapping loci for each read, and (ii) return all reads that have at most n mapping loci (within an error threshold), together with these loci, for any user specified n. Furthermore, mrsFAST-Ultra is SNP-aware, i.e. it can map reads to reference genome while discounting the mismatches that occur at common SNP locations provided by db-SNP; this significantly increases the number of reads that can be mapped to the reference genome. Notice that all of the above features are implemented within the index structure and are not simple post-processing steps and thus are performed highly efficiently. Finally, mrsFAST-Ultra utilizes multiple available cores and processors and can be tuned for various memory settings. Our results show that mrsFAST-Ultra is roughly five times faster than its predecessor mrsFAST. In comparison to newly enhanced popular tools such as Bowtie2, it is more sensitive (it can report 10 times or more mappings per read) and much faster (six times or more) in the multi-mapping mode. Furthermore, mrsFAST-Ultra has an index size of 2GB for the entire human reference genome, which is roughly half of that of Bowtie2. mrsFAST-Ultra is open source and it can be accessed at http://mrsfast.sourceforge.net. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.
Operator Priming and Generalization of Practice in Adults' Simple Arithmetic
ERIC Educational Resources Information Center
Chen, Yalin; Campbell, Jamie I. D.
2016-01-01
There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication,…
No Generalization of Practice for Nonzero Simple Addition
ERIC Educational Resources Information Center
Campbell, Jamie I. D.; Beech, Leah C.
2014-01-01
Several types of converging evidence have suggested recently that skilled adults solve very simple addition problems (e.g., 2 + 1, 4 + 2) using a fast, unconscious counting algorithm. These results stand in opposition to the long-held assumption in the cognitive arithmetic literature that such simple addition problems normally are solved by fact…
Non-enzymatic detection of glucose using poly(azure A)-nickel modified glassy carbon electrode.
Liu, Tong; Luo, Yiqun; Zhu, Jiaming; Kong, Liyan; Wang, Wen; Tan, Liang
2016-08-15
A simple, sensitive and selective non-enzymatic glucose sensor was constructed in this paper. The poly(azure A)-nickel modified glassy carbon electrode was successfully fabricated by the electropolymerization of azure A and the adsorption of Ni(2+). The Ni modified electrode, which was characterized by scanning electron microscope, cyclic voltammetry, electrochemical impedance spectra and X-ray photoelectron spectroscopy measurements, respectively, displayed well-defined current responses of the Ni(III)/Ni(II) couple and showed a good activity for electrocatalytic oxidation of glucose in alkaline medium. Under the optimized conditions, the developed sensor exhibited a broad linear calibration range of 5 μM-12mM for quantification of glucose and a low detection limit of 0.64μM (3σ). The excellent analytical performance including simple structure, fast response time, good anti-interference ability, satisfying stability and reliable reproducibility were also found from the proposed amperometric sensor. The results were satisfactory for the determination of glucose in human serum samples as comparison to those from a local hospital. Copyright © 2016 Elsevier B.V. All rights reserved.
Highly Stretchable and Transparent Microfluidic Strain Sensors for Monitoring Human Body Motions.
Yoon, Sun Geun; Koo, Hyung-Jun; Chang, Suk Tai
2015-12-16
We report a new class of simple microfluidic strain sensors with high stretchability, transparency, sensitivity, and long-term stability with no considerable hysteresis and a fast response to various deformations by combining the merits of microfluidic techniques and ionic liquids. The high optical transparency of the strain sensors was achieved by introducing refractive-index matched ionic liquids into microfluidic networks or channels embedded in an elastomeric matrix. The microfluidic strain sensors offer the outstanding sensor performance under a variety of deformations induced by stretching, bending, pressing, and twisting of the microfluidic strain sensors. The principle of our microfluidic strain sensor is explained by a theoretical model based on the elastic channel deformation. In order to demonstrate its capability of practical usage, the simple-structured microfluidic strain sensors were performed onto a finger, wrist, and arm. The highly stretchable and transparent microfluidic strain sensors were successfully applied as potential platforms for distinctively monitoring a wide range of human body motions in real time. Our novel microfluidic strain sensors show great promise for making future stretchable electronic devices.
Ghari, Tayebeh; Kobarfard, Farzad; Mortazavi, Seyed Alireza
2013-01-01
The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms. PMID:24250672
The generalized scattering coefficient method for plane wave scattering in layered structures
NASA Astrophysics Data System (ADS)
Liu, Yu; Li, Chao; Wang, Huai-Yu; Zhou, Yun-Song
2017-02-01
The generalized scattering coefficient (GSC) method is pedagogically derived and employed to study the scattering of plane waves in homogeneous and inhomogeneous layered structures. The numerical stabilities and accuracies of this method and other commonly used numerical methods are discussed and compared. For homogeneous layered structures, concise scattering formulas with clear physical interpretations and strong numerical stability are obtained by introducing the GSCs. For inhomogeneous layered structures, three numerical methods are employed: the staircase approximation method, the power series expansion method, and the differential equation based on the GSCs. We investigate the accuracies and convergence behaviors of these methods by comparing their predictions to the exact results. The conclusions are as follows. The staircase approximation method has a slow convergence in spite of its simple and intuitive implementation, and a fine stratification within the inhomogeneous layer is required for obtaining accurate results. The expansion method results are sensitive to the expansion order, and the treatment becomes very complicated for relatively complex configurations, which restricts its applicability. By contrast, the GSC-based differential equation possesses a simple implementation while providing fast and accurate results.
Interferometric surface mapping with variable sensitivity.
Jaerisch, W; Makosch, G
1978-03-01
In the photolithographic process, presently employed for the production of integrated circuits, sets of correlated masks are used for exposing the photoresist on silicon wafers. Various sets of masks which are printed in different printing tools must be aligned correctly with respect to the structures produced on the wafer in previous process steps. Even when perfect alignment is considered, displacements and distortions of the printed wafer patterns occur. They are caused by imperfections of the printing tools or/and wafer deformations resulting from high temperature processes. Since the electrical properties of the final integrated circuits and therefore the manufacturing yield depend to a great extent on the precision at which such patterns are superimposed, simple and fast overlay measurements and flatness measurements as well are very important in IC-manufacturing. A simple optical interference method for flatness measurements will be described which can be used under manufacturing conditions. This method permits testing of surface height variations by nearly grazing light incidence by absence of a physical reference plane. It can be applied to polished surfaces and rough surfaces as well.
Abbaspour, Abdolkarim; Khajehzadeh, Abdolreza; Ghaffarinejad, Ali
2009-08-01
In this study, a new, simple, fast and inexpensive method as an alternative to visible spectrophotometry is developed. In this method the cells containing the sample solution were scanned with a scanner, then the color of each cell was analyzed with software written in visual basic (VB 6) media to red, green and blue values. The cells were built by creating holes in the Plexiglas sheet. The dimensions of identical cells were examined by Cr (III) solution with known concentrations. The validity of this new method was studied by determination of dopamine (DA) without using any other reagent. The parameters which affect the system were optimized. The comparison between the current and traditional UV-Vis spectrophotometry methods was studied and the results revealed similar trends in both methods. The developed method was successfully applied to the determination of dopamine in serum and urine without using any pretreatment. Finally comparing the results obtained in the developed method showed that microwave irradiation of the solution can decrease the experimental time, increase sensitivity and improve the limit of detection.
An approximate methods approach to probabilistic structural analysis
NASA Technical Reports Server (NTRS)
Mcclung, R. C.; Millwater, H. R.; Wu, Y.-T.; Thacker, B. H.; Burnside, O. H.
1989-01-01
A major research and technology program in Probabilistic Structural Analysis Methods (PSAM) is currently being sponsored by the NASA Lewis Research Center with Southwest Research Institute as the prime contractor. This program is motivated by the need to accurately predict structural response in an environment where the loadings, the material properties, and even the structure may be considered random. The heart of PSAM is a software package which combines advanced structural analysis codes with a fast probability integration (FPI) algorithm for the efficient calculation of stochastic structural response. The basic idea of PAAM is simple: make an approximate calculation of system response, including calculation of the associated probabilities, with minimal computation time and cost, based on a simplified representation of the geometry, loads, and material. The deterministic solution resulting should give a reasonable and realistic description of performance-limiting system responses, although some error will be inevitable. If the simple model has correctly captured the basic mechanics of the system, however, including the proper functional dependence of stress, frequency, etc. on design parameters, then the response sensitivities calculated may be of significantly higher accuracy.
NASA Astrophysics Data System (ADS)
Shang, Li; Dong, Shaojun
2008-03-01
A simple light scattering detection method for neurotransmitters has been developed, based on the growth of gold nanoparticles. Neurotransmitters (dopamine, L-dopa, noradrenaline and adrenaline) can effectively function as active reducing agents for generating gold nanoparticles, which result in enhanced light scattering signals. The strong light scattering of gold nanoparticles then allows the quantitative detection of the neurotransmitters simply by using a common spectrofluorometer. In particular, Au-nanoparticle seeds were added to facilitate the growth of nanoparticles, which was found to enhance the sensing performance greatly. Using this light scattering technique based on the seed-mediated growth of gold nanoparticles, detection limits of 4.4 × 10-7 M, 3.5 × 10-7 M, 4.1 × 10-7 M, and 7.7 × 10-7 M were achieved for dopamine, L-dopa, noradrenaline and adrenaline, respectively. The present strategy can be extended to detect other biologically important molecules in a very fast, simple and sensitive way, and may have potential applications in a wide range of fields.
NASA Astrophysics Data System (ADS)
Berger, T.; Ziegler, H.; Krausa, Michael
2000-08-01
A huge number of chemical sensors are based on electrochemical measurement methods. Particularly amperometric sensorsystems are employed for the fast detection of pollutants in industry and environment as well as for analytic systems in the medical diagnosis. The large number of different applications of electrochemical sensors is based on the high sensitivity of electrochemical methods and on the wide of possibilities to enhance the selectivity by variation of electrochemical and chemical parameters. Besides this, electrochemical sensorsystems are frequently simple to operate, transportable and cheap. Up to now the electrochemical method of cyclic voltammetry is used only seldom for sensors. Clearly the efficiency of cyclic voltammetry can be seen at the sensorsystem for the detection of nitro- and aminotoluenes in solids and waters as presented here. The potentiodynamic sensors system can be employed for the fast and easy risk estimation of contaminated areas. Because of the high sensitivity of electrochemical methods the detection of chemical substances with a low vapor pressure is possible also. The vapor pressure of TNT at room temperature is 7 ppb for instances. With a special electrochemical set-up we were able to measure TNT approximately 10 cm above a TNT-sample. In addition we were able to estimate TNT in the gaseous phase approximately 10 cm above a real plastic mine. Therefore it seems to be possible to develop an electrochemical mien detection. Moreover, we present that the electrochemical detection of RDX, HMX and chemical warfare agents is also possible.
Tiwari, Dileep; Haque, Shafiul; Tiwari, Ram P; Jawed, Arshad; Govender, Thavendran; Kruger, Hendrik G
2017-04-01
A rapid and efficient diagnostic test was developed for the detection of Mycobacterium tuberculosis antigens in serum samples of active tuberculosis (TB) and extrapulmonary TB patients via a liposomal agglutination-based method. A rapid card test has been developed to facilitate the recognition of high-affinity binding rabbit raised purified culture filtrate protein antibodies coupled on the surface of activated liposomal preparation. In the presence of TB antigens, the polyclonal antibodies bound to the liposomal particles demonstrate a visible agglutination reaction. The developed assay was simple, rapid, reliable, sensitive, and specific as a diagnostic test for the detection of antigens in serum samples of clinically confirmed cases of TB within 4-5 minutes' duration. The test was evaluated at different hospitals, medical colleges, and pathology centers, and involved 1483 participants. This investigation was conducted to detect the presence of these antigens during the period of active growth of the microorganism in serum samples for pulmonary TB and processed tissue biopsy for other extrapulmonary TB. Results obtained using this test were compared with acid-fast bacilli smear and culture results. Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application. Copyright © 2015. Published by Elsevier B.V.
Aszyk, Justyna; Kot, Jacek; Tkachenko, Yurii; Woźniak, Michał; Bogucka-Kocka, Anna; Kot-Wasik, Agata
2017-04-15
A simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography-tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F 2α , 8-iso-15(R)-prostaglandin F 2α , 11β-prostaglandin F 2α , 15(R)-prostaglandin F 2α ) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the most reliable markers of oxidative stress in vivo. Validation of method was performed by evaluation of the key analytical parameters such as: matrix effect, analytical curve, trueness, precision, limits of detection and limits of quantification. As a homoscedasticity was not met for analytical data, weighted linear regression was applied in order to improve the accuracy at the lower end points of calibration curve. The detection limits (LODs) ranged from 1.0 to 2.1pg/mL. For plasma samples spiked with the isoprostanes at the level of 50pg/mL, intra-and interday repeatability ranged from 2.1 to 3.5% and 0.1 to 5.1%, respectively. The applicability of the proposed approach has been verified by monitoring of isoprostane isomers level in plasma samples collected from young patients (n=8) subjected to hyperbaric hyperoxia (100% oxygen at 280kPa(a) for 30min) in a multiplace hyperbaric chamber. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moriarty, Tom
The NREL cell measurement lab measures the IV parameters of cells of multiple sizes and configurations. A large contributing factor to errors and uncertainty in Jsc, Imax, Pmax and efficiency can be the irradiance spatial nonuniformity. Correcting for this nonuniformity through its precise and frequent measurement can be very time consuming. This paper explains a simple, fast and effective method based on bicubic interpolation for determining and correcting for spatial nonuniformity and verification of the method's efficacy.
On the nature of fast sausage waves in coronal loops
NASA Astrophysics Data System (ADS)
Bahari, Karam
2018-05-01
The effect of the parameters of coronal loops on the nature of fast sausage waves are investigated. To do this three models of the coronal loop considered, a simple loop model, a current-carrying loop model and a model with radially structured density called "Inner μ" profile. For all the models the Magnetohydrodynamic (MHD) equations solved analytically in the linear approximation and the restoring forces of oscillations obtained. The ratio of the magnetic tension force to the pressure gradient force obtained as a function of the distance from the axis of the loop. In the simple loop model for all values of the loop parameters the fast sausages wave have a mixed nature of Alfvénic and fast MHD waves, in the current-carrying loop model with thick annulus and low density contrast the fast sausage waves can be considered as purely Alfvénic wave in the core region of the loop, and in the "Inner μ" profile for each set of the parameters of the loop the wave can be considered as a purely Alfvénic wave in some regions of the loop.
Fast parallel tandem mass spectral library searching using GPU hardware acceleration
Baumgardner, Lydia Ashleigh; Shanmugam, Avinash Kumar; Lam, Henry; Eng, Jimmy K.; Martin, Daniel B.
2011-01-01
Mass spectrometry-based proteomics is a maturing discipline of biologic research that is experiencing substantial growth. Instrumentation has steadily improved over time with the advent of faster and more sensitive instruments collecting ever larger data files. Consequently, the computational process of matching a peptide fragmentation pattern to its sequence, traditionally accomplished by sequence database searching and more recently also by spectral library searching, has become a bottleneck in many mass spectrometry experiments. In both of these methods, the main rate limiting step is the comparison of an acquired spectrum with all potential matches from a spectral library or sequence database. This is a highly parallelizable process because the core computational element can be represented as a simple but arithmetically intense multiplication of two vectors. In this paper we present a proof of concept project taking advantage of the massively parallel computing available on graphics processing units (GPUs) to distribute and accelerate the process of spectral assignment using spectral library searching. This program, which we have named FastPaSS (for Fast Parallelized Spectral Searching) is implemented in CUDA (Compute Unified Device Architecture) from NVIDIA which allows direct access to the processors in an NVIDIA GPU. Our efforts demonstrate the feasibility of GPU computing for spectral assignment, through implementation of the validated spectral searching algorithm SpectraST in the CUDA environment. PMID:21545112
Ferry, Barbara; Duchamp-Viret, Patricia
2014-03-14
To test the selectivity of the orexin A (OXA) system in olfactory sensitivity, the present study compared the effects of fasting and of central infusion of OXA on the memory processes underlying odor-malaise association during the conditioned odor aversion (COA) paradigm. Animals implanted with a cannula in the left ventricle received ICV infusion of OXA or artificial cerebrospinal fluid (ACSF) 1 h before COA acquisition. An additional group of intact rats were food-deprived for 24 h before acquisition. Results showed that the increased olfactory sensitivity induced by fasting and by OXA infusion was accompanied by enhanced COA performance. The present results suggest that fasting-induced central OXA release influenced COA learning by increasing not only olfactory sensitivity, but also the memory processes underlying the odor-malaise association.
Ferry, Barbara; Duchamp-Viret, Patricia
2014-01-01
To test the selectivity of the orexin A (OXA) system in olfactory sensitivity, the present study compared the effects of fasting and of central infusion of OXA on the memory processes underlying odor–malaise association during the conditioned odor aversion (COA) paradigm. Animals implanted with a cannula in the left ventricle received ICV infusion of OXA or artificial cerebrospinal fluid (ACSF) 1 h before COA acquisition. An additional group of intact rats were food-deprived for 24 h before acquisition. Results showed that the increased olfactory sensitivity induced by fasting and by OXA infusion was accompanied by enhanced COA performance. The present results suggest that fasting-induced central OXA release influenced COA learning by increasing not only olfactory sensitivity, but also the memory processes underlying the odor–malaise association. PMID:24634353
Fan, Xinghua; Kubwabo, Cariton; Wu, Fang; Rasmussen, Pat E
2018-06-26
Background: Ingestion of house dust has been demonstrated to be an important exposure pathway to several contaminants in young children. These compounds include bisphenol A (BPA), alkylphenols (APs), and alkylphenol ethoxylates (APEOs). Analysis of these compounds in house dust is challenging because of the complex composition of the sample matrix. Objective: The objective was to develop a simple and sensitive method to measure BPA, APs, and APEOs in indoor house dust. Methods: An integrated method that involved solvent extraction using sonication, sample cleanup by solid-phase extraction, derivatization by 2,2,2-trifluoro- N -methyl- N -(trimethylsilyl)acetamide, and analysis by GC coupled with tandem MS was developed for the simultaneous determination of BPA, APs, and APEOs in NIST Standard Reference Material (SRM) 2585 (Organic contaminants in house dust) and in settled house dust samples. Results: Target analytes included BPA, 4- tert -octylphenol (OP), OP monoethoxylate, OP diethoxylate, 4- n -nonylphenol (4 n NP), 4 n NP monoethoxylate (4 n NP 1 EO), branched nonylphenol (NP), NP monoethoxylate, NP diethoxylate, NP triethoxylate, and NP tetraethoxylate. The method was sensitive, with method detection limits ranging from 0.05 to 5.1 μg/g, and average recoveries between 82 and 115%. All target analytes were detected in SRM 2585 and house dust except 4 n NP and 4 n NP 1 EO. Conclusions: The method is simple and fast, with high sensitivity and good reproducibility. It is applicable to the analysis of target analytes in similar matrixes, such as sediments, soil, and biosolids. Highlights: Values measured in SRM 2585 will be useful for future research in method development and method comparison.
Shutterless ion mobility spectrometer with fast pulsed electron source
NASA Astrophysics Data System (ADS)
Bunert, E.; Heptner, A.; Reinecke, T.; Kirk, A. T.; Zimmermann, S.
2017-02-01
Ion mobility spectrometers (IMS) are devices for fast and very sensitive trace gas analysis. The measuring principle is based on an initial ionization process of the target analyte. Most IMS employ radioactive electron sources, such as 63Ni or 3H. These radioactive materials have the disadvantage of legal restrictions and the electron emission has a predetermined intensity and cannot be controlled or disabled. In this work, we replaced the 3H source of our IMS with 100 mm drift tube length with our nonradioactive electron source, which generates comparable spectra to the 3H source. An advantage of our emission current controlled nonradioactive electron source is that it can operate in a fast pulsed mode with high electron intensities. By optimizing the geometric parameters and developing fast control electronics, we can achieve very short electron emission pulses for ionization with high intensities and an adjustable pulse width of down to a few nanoseconds. This results in small ion packets at simultaneously high ion densities, which are subsequently separated in the drift tube. Normally, the required small ion packet is generated by a complex ion shutter mechanism. By omitting the additional reaction chamber, the ion packet can be generated directly at the beginning of the drift tube by our pulsed nonradioactive electron source with only slight reduction in resolving power. Thus, the complex and costly shutter mechanism and its electronics can also be omitted, which leads to a simple low-cost IMS-system with a pulsed nonradioactive electron source and a resolving power of 90.
Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.
Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E
2018-02-20
Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2 > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.
Verkest, K R; Fleeman, L M; Morton, J M; Ishioka, K; Rand, J S
2011-07-01
The hormonal mediators of obesity-induced insulin resistance and compensatory hyperinsulinemia in dogs have not been identified. Plasma samples were obtained after a 24-h fast from 104 client-owned lean, overweight, and obese dogs. Plasma glucose and insulin concentrations were used to calculate insulin sensitivity and β-cell function with the use of the homeostasis model assessment (HOMA(insulin sensitivity) and HOMA(β-cell function), respectively). Path analysis with multivariable linear regression was used to identify whether fasting plasma leptin, adiponectin, or glucagon-like peptide-1 concentrations were associated with adiposity, insulin sensitivity, and basal insulin secretion. None of the dogs were hyperglycemic. In the final path model, adiposity was positively associated with leptin (P < 0.01) and glucagon-like peptide-1 (P = 0.04) concentrations. No significant total effect of adiposity on adiponectin in dogs (P = 0.24) was observed. If there is a direct effect of leptin on adiponectin, then our results indicate that this is a positive relationship, which at least partly counters a negative direct relationship between adiposity and adiponectin. Fasting plasma leptin concentration was directly negatively associated with fasting insulin sensitivity (P = 0.01) and positively associated with β-cell function (P < 0.01), but no direct association was observed between adiponectin concentration and either insulin sensitivity or β-cell function (P = 0.42 and 0.11, respectively). We conclude that dogs compensate effectively for obesity-induced insulin resistance. Fasting plasma leptin concentrations appear to be associated with obesity-associated changes in insulin sensitivity and compensatory hyperinsulinemia in naturally occurring obese dogs. Adiponectin does not appear to be involved in the pathophysiology of obesity-associated changes in insulin sensitivity. Copyright © 2011 Elsevier Inc. All rights reserved.
Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K
2018-03-01
Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (p<0.001) versus 3D-QCA %area stenosis (AUC: 77.5% [95% CI: 69.8-85.3%]). There was a good correlation between virtual resting Pd/Pa and FFR (r=0.69, p<0.001). Virtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Fast T Wave Detection Calibrated by Clinical Knowledge with Annotation of P and T Waves
Elgendi, Mohamed; Eskofier, Bjoern; Abbott, Derek
2015-01-01
Background There are limited studies on the automatic detection of T waves in arrhythmic electrocardiogram (ECG) signals. This is perhaps because there is no available arrhythmia dataset with annotated T waves. There is a growing need to develop numerically-efficient algorithms that can accommodate the new trend of battery-driven ECG devices. Moreover, there is also a need to analyze long-term recorded signals in a reliable and time-efficient manner, therefore improving the diagnostic ability of mobile devices and point-of-care technologies. Methods Here, the T wave annotation of the well-known MIT-BIH arrhythmia database is discussed and provided. Moreover, a simple fast method for detecting T waves is introduced. A typical T wave detection method has been reduced to a basic approach consisting of two moving averages and dynamic thresholds. The dynamic thresholds were calibrated using four clinically known types of sinus node response to atrial premature depolarization (compensation, reset, interpolation, and reentry). Results The determination of T wave peaks is performed and the proposed algorithm is evaluated on two well-known databases, the QT and MIT-BIH Arrhythmia databases. The detector obtained a sensitivity of 97.14% and a positive predictivity of 99.29% over the first lead of the validation databases (total of 221,186 beats). Conclusions We present a simple yet very reliable T wave detection algorithm that can be potentially implemented on mobile battery-driven devices. In contrast to complex methods, it can be easily implemented in a digital filter design. PMID:26197321
H.sub.2O doped WO.sub.3, ultra-fast, high-sensitivity hydrogen sensors
Liu, Ping [Denver, CO; Tracy, C Edwin [Golden, CO; Pitts, J Roland [Lakewood, CO; Lee, Se-Hee [Lakewood, CO
2011-03-22
An ultra-fast response, high sensitivity structure for optical detection of low concentrations of hydrogen gas, comprising: a substrate; a water-doped WO.sub.3 layer coated on the substrate; and a palladium layer coated on the water-doped WO.sub.3 layer.
NASA Astrophysics Data System (ADS)
Tashkhourian, Javad; Absalan, Ghodratollah; Jafari, Marzieh; Zare, Saber
2016-01-01
A rapid, simple and inexpensive spectrofluorimetric sensor for determination of doxycycline based on its interaction with thioglycolic acid-capped cadmium telluride quantum dots (TGA/CdTe QDs) has been developed. Under the optimum experimental conditions, the sensor exhibited a fast response time of <10 s. The results revealed that doxycycline could quench the fluorescence of TGA/CdTe QDs via electron transfer from the QDs to doxycycline through a dynamic quenching mechanism. The sensor permitted determination of doxycycline in a concentration range of 1.9 × 10-6-6.1 × 10-5 mol L-1 with a detection limit of 1.1 × 10-7 mol L-1. The sensor was applied for determination of doxycycline in honey and human serum samples.
Atlas of susceptibility to pollution in marinas. Application to the Spanish coast.
Gómez, Aina G; Ondiviela, Bárbara; Fernández, María; Juanes, José A
2017-01-15
An atlas of susceptibility to pollution of 320 Spanish marinas is provided. Susceptibility is assessed through a simple, fast and low cost empirical method estimating the flushing capacity of marinas. The Complexity Tidal Range Index (CTRI) was selected among eleven empirical methods. The CTRI method was selected by means of statistical analyses because: it contributes to explain the system's variance; it is highly correlated to numerical model results; and, it is sensitive to marinas' location and typology. The process of implementation to the Spanish coast confirmed its usefulness, versatility and adaptability as a tool for the environmental management of marinas worldwide. The atlas of susceptibility, assessed through CTRI values, is an appropriate instrument to prioritize environmental and planning strategies at a regional scale. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lou, Shishu; Zhu, Huishi; Hu, Shaoxu; Zhao, Chunhua; Han, Peide
2015-01-01
Characterization of the diffusion length of solar cells in space has been widely studied using various methods, but few studies have focused on a fast, simple way to obtain the quantified diffusion length distribution on a silicon wafer. In this work, we present two different facile methods of doing this by fitting photoluminescence images taken in two different wavelength ranges or from different sides. These methods, which are based on measuring the ratio of two photoluminescence images, yield absolute values of the diffusion length and are less sensitive to the inhomogeneity of the incident laser beam. A theoretical simulation and experimental demonstration of this method are presented. The diffusion length distributions on a polycrystalline silicon wafer obtained by the two methods show good agreement. PMID:26364565
DAVIS: A direct algorithm for velocity-map imaging system
NASA Astrophysics Data System (ADS)
Harrison, G. R.; Vaughan, J. C.; Hidle, B.; Laurent, G. M.
2018-05-01
In this work, we report a direct (non-iterative) algorithm to reconstruct the three-dimensional (3D) momentum-space picture of any charged particles collected with a velocity-map imaging system from the two-dimensional (2D) projected image captured by a position-sensitive detector. The method consists of fitting the measured image with the 2D projection of a model 3D velocity distribution defined by the physics of the light-matter interaction. The meaningful angle-correlated information is first extracted from the raw data by expanding the image with a complete set of Legendre polynomials. Both the particle's angular and energy distributions are then directly retrieved from the expansion coefficients. The algorithm is simple, easy to implement, fast, and explicitly takes into account the pixelization effect in the measurement.
Bamdad, Shahram; Beigi, Vahid; Sedaghat, Mohammad Reza
2017-01-01
Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field defect in glaucoma disease. This prospective observational case series study was conducted in a university-based eye hospital. A total of 37 eyes of 20 patients with glaucoma were evaluated using the central 30-2 program and both the SITA Fast and SFT strategies. Both strategies were performed for each strategy in each session and for four times in a 2-week period. Data were analyzed using the Student's t-test, analysis of variance, and chi-square test. The SITA Fast and SFT strategies had similar sensitivity of 93.3%. The specificity of SITA Fast and SFT strategies was 57.4% and 71.4% respectively. The mean duration of SFT tests was 14.6 minutes, and that of SITA Fast tests was 5.45 minutes (a statistically significant 62.5% reduction). In gray scale plots, visual field defect was less deep in SITA Fast than in SFT; however, more points had significant defect (p < 0.5% and p < 1%) in pattern deviation plots in SITA Fast than in SFT; these differences were not clinically significant. In conclusion, the SITA Fast strategy showed higher sensitivity for detection of glaucoma compared to the SFT strategy, yet with reduced specificity; however, the shorter test duration makes it a more acceptable choice in many clinical situations, especially for children, elderly, and those with musculoskeletal diseases.
Martel, Cécile; Pinçon, Anthony; Bélanger, Alexandre Maxime; Luo, Xiaoyan; Gillis, Marc-Antoine; de Montgolfier, Olivia; Thorin-Trescases, Nathalie; Thorin, Éric
2018-01-01
Angiopoietin-like 2 (ANGPTL2) is an inflammatory adipokine linking obesity to insulin resistance. Intermittent fasting, on the other hand, is a lifestyle intervention able to prevent obesity and diabetes but difficult to implement and maintain. Our objectives were to characterize a link between ANGPTL2 and intermittent fasting and to investigate whether the knockdown of ANGPTL2 reproduces the benefits of intermittent fasting on weight gain and insulin responsiveness in knockdown and wild-type littermates mice. Intermittent fasting, access to food ad libitum once every other day, was initiated at the age of three months and maintained for four months. Intermittent fasting decreased by 63% (p < 0.05) gene expression of angptl2 in adipose tissue of wild-type mice. As expected, intermittent fasting improved insulin sensitivity (p < 0.05) and limited weight gain (p < 0.05) in wild-type mice. Knockdown mice fed ad libitum, however, were comparable to wild-type mice following the intermittent fasting regimen: insulin sensitivity and weight gain were identical, while intermittent fasting had no additional impact on these parameters in knockdown mice. Energy intake was similar between both wild-type fed intermittent fasting and ANGPTL2 knockdown mice fed ad libitum, suggesting that intermittent fasting and knockdown of ANGPTL2 equally lower feeding efficiency. These results suggest that the reduction of ANGPTL2 could be a useful and promising strategy to prevent obesity and insulin resistance, although further investigation of the mechanisms linking ANGPTL2 and intermittent fasting is warranted. Impact statement Intermittent fasting is an efficient diet pattern to prevent weight gain and improve insulin sensitivity. It is, however, a difficult regimen to follow and compliance is expected to be very low. In this work, we demonstrate that knockdown of ANGPTL2 in mice fed ad libitum mimics the beneficial effects of intermittent fasting on weight gain and insulin sensitivity in wild-type mice. ANGPTL2 is a cytokine positively associated with fat mass in humans, which inactivation in mice improves resistance to a high-fat metabolic challenge. This study provides a novel pathway by which IF acts to limit obesity despite equivalent energy intake. The development of a pharmacological ANGPTL2 antagonist could provide an efficient tool to reduce the burden of obesity.
Preoperative oral carbohydrates and postoperative insulin resistance.
Nygren, J; Soop, M; Thorell, A; Sree Nair, K; Ljungqvist, O
1999-04-01
Infusions of carbohydrates before surgery have been shown to reduce postoperative insulin resistance. Presently, we investigated the effects of a carbohydrate drink, given shortly before surgery, on postoperative insulin sensitivity. Insulin sensitivity and glucose turnover ([6, 6,(2)H(2)]-D-glucose) were measured using hyper-insulinemic, normoglycemic clamps before and after elective surgery. Sixteen patients undergoing total hip replacement were randomly assigned to preoperative oral carbohydrate administration (CHO-H, n = 8) or the same amount of a placebo drink (placebo, n = 8) before surgery. Insulin sensitivity was measured before and immediately after surgery. Patients undergoing elective colorectal surgery were studied before surgery and 24 h postoperatively (CHO-C (n = 7), and fasted (n = 7), groups). The fasted group underwent surgery after an overnight fast. In both studies, the CHO groups received 800 ml of an isoosmolar carbohydrate rich beverage the evening before the operation (100g carbohydrates), as well as another 400 ml (50g carbohydrates) 2 h before the initiation of anesthesia. Immediately after surgery, insulin sensitivity was reduced 37% in the placebo group (P < 0.05 vs. preoperatively) while no significant change was found in the CHO-H group (-16%, p = NS). During clamps performed 24h postoperatively, insulin sensitivity and whole-body glucose disposal was reduced in both groups, but the reduction was greater compared to that in the CHO-C group (-49 +/- 6% vs. -26 +/- 8%, P> 0.05 fasted vs. CHO-C). Patients given a carbohydrate drink shortly before elective surgery displayed less reduced insulin sensitivity after surgery as compared to patients undergoing surgery after an overnight fast. Copyright 1999 Harcourt Publishers Ltd.
A novel diagnostic biomarker panel for obesity-related nonalcoholic steatohepatitis (NASH).
Younossi, Zobair M; Jarrar, Mohammed; Nugent, Clare; Randhawa, Manpreet; Afendy, Mariam; Stepanova, Maria; Rafiq, Nila; Goodman, Zachary; Chandhoke, Vikas; Baranova, Ancha
2008-11-01
Within the spectrum of nonalcoholic fatty liver disease (NAFLD), only patients with nonalcoholic steatohepatitis (NASH) show convincing evidence for progression. To date, liver biopsy remains the gold standard for the diagnosis of NASH; however, liver biopsy is expensive and associated with a small risk, emphasizing the urgent need for noninvasive diagnostic biomarkers. Recent findings suggest a role for apoptosis and adipocytokines in the pathogenesis of NASH. The aim of this study was to develop a noninvasive diagnostic biomarker for NASH. The study included 101 patients with liver biopsies who were tested with enzyme-linked immunosorbent assay (ELISA)-based assays. Of these, 69 were included in the biomarker development set and 32 were included in the biomarker validation set. Clinical data and serum samples were collected at the time of biopsy. Fasting serum samples were assayed for adiponectin, resistin, insulin, glucose, TNF-alpha, IL-6, IL-8, cytokeratin CK-18 (M65 antigen), and caspase-cleaved CK-18 (M30 antigen). Data analysis revealed that the levels of M30 antigen (cleaved CK-18) predicted histological NASH with 70% sensitivity and 83.7% specificity and area under the curve (AUC) = 0.711, p < 10(-4), whereas the predictive value of the levels of intact CK-18 (M65) was higher (63.6% sensitivity and 89.4% specificity and AUC = 0.814, p < 10(-4)). Histological NASH could be predicted by a combination of Cleaved CK-18, a product of the subtraction of Cleaved CK-18 level from intact CK-18 level, serum adiponectin, and serum resistin with a sensitivity of 95.45% sensitivity, specificity of 70.21%, and AUC of 0.908 (p < 10(-4)). Blinded validation of this model confirmed its reliability for separating NASH from simple steatosis. Four ELISA-based tests were combined to form a simple diagnostic biomarker for NASH.
Effects of acarbose treatment on markers of insulin sensitivity and systemic inflammation.
Rudovich, Natalia N; Weickert, Martin O; Pivovarova, Olga; Bernigau, Wolfgang; Pfeiffer, Andreas F H
2011-06-01
This study assessed the effect of postprandial glucose reduction by acarbose on insulin sensitivity and biomarkers of systemic inflammation. This was a single-center, double-blind, randomized, placebo-controlled, crossover study <40 weeks in duration, involving 66 subjects with varying degrees of glucose tolerance. Eligible patients completed a 3-week run-in period and were randomized to receive either 100 mg of acarbose three times daily followed by placebo, or vice versa, lasting 12 weeks each with a 12-week washout between interventions. Liquid meal challenges and hyperinsulinemic-euglycemic glucose clamp were performed at weeks 0, 12, 24, and 36. Fasting proinsulin levels and proinsulin-to-adiponectin ratios but not fasting adiponectin levels were significantly lower during acarbose versus placebo treatment. Clamp-derived insulin sensitivity index and body weight were unchanged by the intervention. Levels of fasting insulin, fasting glucose, monocyte chemoattractant protein-1, interleukin-6, and interleukin-1β were comparable between treatments. In the liquid meal challenge tests, postprandial glucose and insulin responses were significantly lower during acarbose versus placebo treatment. The effects of acarbose on the reduction of fasting proinsulin was most pronounced in subjects with impaired fasting glucose/impaired glucose tolerance (n = 24). Reduction of the glycemic load by acarbose decreased fasting levels of proinsulin but had no effect on adiponectin and whole-body insulin sensitivity as well as biomarkers reflecting inflammation. The preventive effects of acarbose on type 2 diabetes mellitus and cardiovascular risk need further investigation and cannot be explained by changes of insulin resistance and inflammatory biomarkers.
Di Corcia, D; Lisi, S; Pirro, V; Gerace, E; Salomone, A; Vincenti, M
2013-05-15
A simple and extremely fast procedure for the quantitative determination in oral fluid samples of 44 substances, including the most common drugs of abuse and several pharmaceutical drugs, was developed and fully validated. Preliminary sample treatment was limited to protein precipitation. The resulting acetonitrile solution was directly injected into an ultra-high performance liquid chromatograph (UHPLC) equipped with a C18 column (100mm×2.1mm, 1.7μm). The mobile phase eluted with linear gradient (water/formic acid 5mM: acetonitrile/formic acid 5mM; v:v) from 98:2 to 0:100 in 5.0min, followed by isocratic elution at 100% B for 1.0min. The flow rate was 0.6mL/min and the total run time was 9.0min including re-equilibration at the initial conditions. The analytes were revealed by a triple quadrupole mass spectrometer operating in the selected reaction monitoring mode. The method proved to be simple, accurate, rapid and highly sensitive, allowing the simultaneous detection of all compounds. The ease of sample treatment, together with the wide range of detectable substances, all with remarkable analytical sensitivity, make this procedure ideal for the screening of large populations in several forensic and clinical contexts, whenever oral fluid sampling has to be preferred to blood sampling, as for example in short retrospective investigations. Copyright © 2013 Elsevier B.V. All rights reserved.
Developing a new intelligent system for the diagnosis of tuberculous pleural effusion.
Li, Chengye; Hou, Lingxian; Sharma, Bishundat Yanesh; Li, Huaizhong; Chen, ChengShui; Li, Yuping; Zhao, Xuehua; Huang, Hui; Cai, Zhennao; Chen, Huiling
2018-01-01
In countries with high prevalence of tuberculosis (TB), clinicians often diagnose tuberculous pleural effusion (TPE) by using diagnostic tests, which have not only poor sensitivity, but poor availability as well. The aim of our study is to develop a new artificial intelligence based diagnostic model that is accurate, fast, non-invasive and cost effective to diagnose TPE. It is expected that a tool derived based on the model be installed on simple computer devices (such as smart phones and tablets) and be used by clinicians widely. For this study, data of 140 patients whose clinical signs, routine blood test results, blood biochemistry markers, pleural fluid cell type and count, and pleural fluid biochemical tests' results were prospectively collected into a database. An Artificial intelligence based diagnostic model, which employs moth flame optimization based support vector machine with feature selection (FS-MFO-SVM), is constructed to predict the diagnosis of TPE. The optimal model results in an average of 95% accuracy (ACC), 0.9564 the area under the receiver operating characteristic curve (AUC), 93.35% sensitivity, and 97.57% specificity for FS-MFO-SVM. The proposed artificial intelligence based diagnostic model is found to be highly reliable for diagnosing TPE based on simple clinical signs, blood samples and pleural effusion samples. Therefore, the proposed model can be widely used in clinical practice and further evaluated for use as a substitute of invasive pleural biopsies. Copyright © 2017 Elsevier B.V. All rights reserved.
Kokulnathan, Thangavelu; Kumar, Jeyaraj Vinoth; Chen, Shen-Ming; Karthik, Raj; Elangovan, Arumugam; Muthuraj, Velluchamy
2018-06-01
In the modern world, the contamination of ecosystem by human and veterinary pharmaceutical drugs through the metabolic excretion, improper disposal/industrial waste has been subjected to a hot issue. Therefore, exploitation of exclusive structured material and reliable technique is a necessary task to the precise detection of drugs. With this regards, we made an effort for the fabrication of novel one-dimensional (1D) stannous tungstate nanorods (β-SnW NRs) via simple sonochemical approach and used as an electrochemical sensor for the detection of antipsychotic drug chlorpromazine (CPZ) for the first time. The crystallographic structure, surface topology, elemental compositions and their distributions and ionic states were enquired by different spectroscopic techniques such as XRD, FTIR, SEM, EDS, elemental mapping and XPS analysis. The developed β-SnW NRs/GCE sensor exhibits a rapid and sensitive electrochemical response towards CPZ sensing with wide linear response range (0.01-457 µM), high sensitivity (2.487 µA µM -1 cm -2 ), low detection limit (0.003 µM) and excellent selectivity. Besides, the as-proposed electrochemical sensor was successfully applied to real sample analysis in commercial CPZ drug and biological fluids and the acquired recovery results are quite satisfactory. The proposed sonochemical method for the preparation of β-SnW NRs is low cost, very simple, fast and efficient for sensor applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Mushi, Martha Fidelis; Paterno, Laurent; Tappe, Dennis; Deogratius, Anna Pendo; Seni, Jeremiah; Moremi, Nyambura; Mirambo, Mariam Mwijuma; Mshana, Stephen Eliatosha
2014-01-01
Campylobacter species are recognized as a major cause of acute gastroenteritis in humans throughout the world. The diagnosis is mainly based on stool culture. This study was done to evaluate the effectiveness of staining methods (Gram stain using 0.3% carbol fuchsin as counter stain and 1% carbol fuchsin direct stain) versus culture as the gold standard. A total of 300 children attending Bugando Medical Centre (BMC) and the Sekou Toure regional hospital with acute watery diarrhea were enrolled. Two sets of slides were prepared stained with 1% carbol fuchsin for 30 seconds first set, and the second set stained with Gram's stain using 0.3% carbol fuchsin as counter stain for five minutes. Concurrently, stool samples were inoculated on Preston Agar selective. Of 300 stool specimens, 14(4.7%) showed positive culture after 48 hours of incubation and 28 (9.3%) shows typical morphology of Campylobacter species by both Gram stain and direct stain. The sensitivity of the Gram stain using 0.3% carbol fuchsin as counter stain and 1% carbol fuchsin simple stain versus culture as gold standard was 64.3%, with a specificity of 93.4%. The positive predictive value and negative predictive value were 32.1% and 98.2% respectively. The detection of Campylobacter by 1% carbol fuchsin is simple, inexpensive, and fast, with both a high sensitivity and specificity. Laboratories in settings with high prevalence of campylobacteriosis and/or limited resources can employ 1% carbol fuchsin direct stain in detecting campylobacter infections.
Effects of Ramadan fasting on glucose homeostasis and adiponectin levels in healthy adult males.
Gnanou, Justin V; Caszo, Brinnell A; Khalil, Khalifah M; Abdullah, Shahidah L; Knight, Victor F; Bidin, Mohd Z
2015-01-01
Adiponectin is a hormone secreted by adipocytes during the fasting phase of the fast-fed cycle. Ramadan fasting involves prolonged fasting for up to twelve hours and thus could lead to increased secretion of adiponectin by adipocytes. However, studies on the role of adiponectin on glucose and body weight homeostasis during Ramadan fasting is still a matter of controversy. Thus the specific aim of this study was to assess the effect of fasting during Ramadan on the adiponectin levels, body weight and glucose homeostasis in healthy male Malaysian subjects. Twenty healthy male (19-23 years) Muslim subjects were followed up during the fasting month of Ramadan. Anthropometry and blood samples were taken one week before and during the fourth week of fasting. Plasma glucose, insulin and adiponectin were estimated and insulin sensitivity indices were estimated using the Homeostasis Model Assessment. Subjects experienced a significant decrease in body weight (2.4 %, p < 0.001) and body mass index (5.5 %, p < 0.01). There was also a significant decrease of 12.3 %, 52.8 % and 45.6 % of plasma glucose, insulin and adiponectin respectively (p < 0.01). The drop in adiponectin was positively correlated with the decrease in body weight (r = 0.45, p < 0.05). There was also a significant increase in insulin sensitivity and a decrease in insulin resistance (p < 0.01). These results indicate that Ramadan fasting in young healthy individuals has a positive impact on the maintenance of glucose homeostasis. It also shows that adiponectin levels dropped along with significant loss in weight. We feel caloric restriction during the Ramadan fasting is in itself sufficient to improve insulin sensitivity in healthy individuals.
Tummers, W; van Schuppen, J; Langeveld, H; Wilde, J; Banderker, E; van As, A
2016-06-01
The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical decision-making regarding paediatric BAT. Children presented at the Trauma Unit of the Red Cross War Memorial Children's Hospital, Cape Town, after HET, and underwent both a physical examination and a FAST. The presence of free fluid in the abdomen and pelvis was assessed using a FAST. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) for identifying intraabdominal injury were calculated for the physical examination and the FAST, both individually and when combined. Seventy-five patients were included as per the criteria for HET as follows: pedestrian motor vehicle crashes (MVCs) ( n = 46), assault ( n = 14), fall from a height ( n = 9), MVC passenger ( n = 4) and other ( n = 2). The ages of the patients ranged from 3 months to 13 years. The sensitivity of the physical examination was 0.80, specificity 0.83, PPV 0.42 and NPV 0.96. The sensitivity of the FAST was 0.50, specificity 1.00, PPV 1.00 and NPV 0.93. Sensitivity increased to 0.90 when the physical examination was combined with the FAST. Nonoperative management was used in 73 patients. Two underwent an operation. A FAST should be performed in combination with a physical examination on every paediatric patient involved in HET to detect BAT. When both are negative, nonoperative management can be implemented without fear of missing a clinically significant injury. FAST is a safe, effective and easily accessible alternative to CT, which avoids ionising radiation and aids in clinical decision-making.
Pont, Frédéric; Fournié, Jean Jacques
2010-03-01
MS, the reference technology for proteomics, routinely produces large numbers of protein lists whose fast comparison would prove very useful. Unfortunately, most softwares only allow comparisons of two to three lists at once. We introduce here nwCompare, a simple tool for n-way comparison of several protein lists without any query language, and exemplify its use with differential and shared cancer cell proteomes. As the software compares character strings, it can be applied to any type of data mining, such as genomic or metabolomic datalists.
Fast computation of derivative based sensitivities of PSHA models via algorithmic differentiation
NASA Astrophysics Data System (ADS)
Leövey, Hernan; Molkenthin, Christian; Scherbaum, Frank; Griewank, Andreas; Kuehn, Nicolas; Stafford, Peter
2015-04-01
Probabilistic seismic hazard analysis (PSHA) is the preferred tool for estimation of potential ground-shaking hazard due to future earthquakes at a site of interest. A modern PSHA represents a complex framework which combines different models with possible many inputs. Sensitivity analysis is a valuable tool for quantifying changes of a model output as inputs are perturbed, identifying critical input parameters and obtaining insight in the model behavior. Differential sensitivity analysis relies on calculating first-order partial derivatives of the model output with respect to its inputs. Moreover, derivative based global sensitivity measures (Sobol' & Kucherenko '09) can be practically used to detect non-essential inputs of the models, thus restricting the focus of attention to a possible much smaller set of inputs. Nevertheless, obtaining first-order partial derivatives of complex models with traditional approaches can be very challenging, and usually increases the computation complexity linearly with the number of inputs appearing in the models. In this study we show how Algorithmic Differentiation (AD) tools can be used in a complex framework such as PSHA to successfully estimate derivative based sensitivities, as is the case in various other domains such as meteorology or aerodynamics, without no significant increase in the computation complexity required for the original computations. First we demonstrate the feasibility of the AD methodology by comparing AD derived sensitivities to analytically derived sensitivities for a basic case of PSHA using a simple ground-motion prediction equation. In a second step, we derive sensitivities via AD for a more complex PSHA study using a ground motion attenuation relation based on a stochastic method to simulate strong motion. The presented approach is general enough to accommodate more advanced PSHA studies of higher complexity.
Rigamonti, A E; Bini, S; Grugni, G; Agosti, F; De Col, A; Mallone, M; Cella, S G; Sartorio, A
2014-10-01
The effect of eating rate on the release of anorexigenic gut peptides in Prader-Willi syndrome (PWS), a neurogenetic disorder clinically characterized by hyperphagia and excessive obesity, has not been investigated so far. Postprandial PYY and GLP-1 levels to fast (5 min) and slow (30 min) ice cream consumption were measured in PWS adult patients and age-matched patients with simple obesity and normal-weighted subjects. Visual analog scales (VASs) were used to evaluate the subjective feelings of hunger and satiety. Fast ice cream consumption stimulated GLP-1 release in normal subjects, a greater increase being observed with slow feeding. Fast or slow feeding did not change circulating levels of GLP-1 in obese patients, while, unexpectedly, fast feeding (but not slow feeding) stimulated GLP-1 release in PWS patients. Plasma PYY concentrations increased in all groups, irrespective of the eating rate. Slow feeding was more effective in stimulating PYY release in normal subjects, while fast feeding was more effective in PWS patients. Slow feeding evoked a lower hunger and higher satiety compared with fast feeding in normal subjects, this finding being not evident in obese patients. Unexpectedly, fast feeding evoked a lower hunger and higher satiety in PWS patients in comparison with slow feeding. Fast feeding leads to higher concentrations of anorexigenic gut peptides and favours satiety in PWS adult patients, this pattern being not evident in age-matched patients with simple obesity, thus suggesting the existence of a different pathophysiological substrate in these two clinical conditions. © 2013 John Wiley & Sons Ltd.
In-situ growth of AuNPs on WS2@U-bent optical fiber for evanescent wave absorption sensor
NASA Astrophysics Data System (ADS)
Zhang, Suzhen; Zhao, Yuefeng; Zhang, Chao; Jiang, Shouzhen; Yang, Cheng; Xiu, Xianwu; Li, Chonghui; Li, Zhen; Zhao, Xiaofei; Man, Baoyuan
2018-05-01
The sensitivity of the evanescent wave absorption sensor is always a hot topic which has been attracted researchers' discussion. It is still a challenge for developing the effective sensor to sensitively detect some biochemical molecules solution in a simple and low-cost way. In this paper, an evanescent wave absorption (EWA) sensor has been presented based on the U-bent multimode fiber coated with tungsten disulfide (WS2) film and in-situ growth of gold nanoparticles (AuNPs) for the detection of ethanol solution and sodium chloride (NaCl) solution. Benefitted from the effective light coupling produced between U-bent probe and AuNPs, we attained the optimal size of the AuNPs by changing the reaction time between WS2 and tetrachloroauric acid (HAuCl4). With the AuNPs/WS2@U-bent optical fiber, we discussed the behaviors of EWA sensor, such as sensitivity, reproducibility, fast response-recovery time and stability. The sensitivity (△A/△C) of the proposed AuNPs/WS2@U-bent optical fiber EWA sensor is 0.65 for the detection of the ethanol solution. Besides, the AuNPs/WS2@U-bent optical fiber EWA sensor exhibits high sensitivity in detection of the sodium chloride (NaCl), which can reach 1.5 when the proposed sensor was immersed into NaCl solution. Our work demonstrates that the U-bent optical fiber EWA sensor may have promising applications in testing the solution of concentration.
Juillet, Y; Dubois, C; Bintein, F; Dissard, J; Bossée, A
2014-08-01
A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography-mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95%). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention.
Graphene nano-ink biosensor arrays on a microfluidic paper for multiplexed detection of metabolites.
Labroo, Pratima; Cui, Yue
2014-02-27
The development of a miniaturized and low-cost platform for the highly sensitive, selective and rapid detection of multiplexed metabolites is of great interest for healthcare, pharmaceuticals, food science, and environmental monitoring. Graphene is a delicate single-layer, two-dimensional network of carbon atoms with extraordinary electrical sensing capability. Microfluidic paper with printing technique is a low cost matrix. Here, we demonstrated the development of graphene-ink based biosensor arrays on a microfluidic paper for the multiplexed detection of different metabolites, such as glucose, lactate, xanthine and cholesterol. Our results show that the graphene biosensor arrays can detect multiple metabolites on a microfluidic paper sensitively, rapidly and simultaneously. The device exhibits a fast measuring time of less than 2 min, a low detection limit of 0.3 μM, and a dynamic detection range of 0.3-15 μM. The process is simple and inexpensive to operate and requires a low consumption of sample volume. We anticipate that these results could open exciting opportunities for a variety of applications. Copyright © 2014 Elsevier B.V. All rights reserved.
A Fast Responsive Ultraviolet Sensor from mSILAR-Processed Sn-ZnO
NASA Astrophysics Data System (ADS)
Thomas, Deepu; Vijayalakshmi, K. A.; Sadasivuni, Kishor Kumar; Thomas, Ajith; Ponnamma, Deepalekshmi; Cabibihan, John-John
2017-11-01
Microwave-assisted successive ionic layer adsorption and reaction was employed to synthesize Sn-ZnO (tin-doped zinc oxide), and its sensitivity to ultraviolet radiation is compared with zinc oxide (ZnO). The sensing films were made by the dip-coated method on an indium titanium oxide glass substrate, and the sensing performance was monitored using the 300-700 nm wavelength of UV-Vis light. Excellent sensitivity and recovery were observed for the Sn-doped ZnO sensor device, especially at 380 nm wavelength of ultraviolet (UV) light (response and recovery time 2.26 s and 8.63 s, respectively, at 5 V bias voltage). The variation in photocurrent with respect to dark and light illumination atmosphere was well illustrated based on the Schottky and inter-particle network effects. Doping of Sn on ZnO nanoparticles varied the surface roughness and crystallite size as observed from scanning electron microscopic and x-ray diffraction studies. Here, we demonstrate a simple and economical fabrication technique for designing a high-performance UV light sensor. The developed device works at room temperature with high durability and stability.
Kamel, Katarzyna A; Kroc, Magdalena; Święcicki, Wojciech
2015-01-01
Sequence tagged site (STS) markers are valuable tools for genetic and physical mapping that can be successfully used in comparative analyses among related species. Current challenges for molecular markers genotyping in plants include the lack of fast, sensitive and inexpensive methods suitable for sequence variant detection. In contrast, high resolution melting (HRM) is a simple and high-throughput assay, which has been widely applied in sequence polymorphism identification as well as in the studies of genetic variability and genotyping. The present study is the first attempt to use the HRM analysis to genotype STS markers in narrow-leafed lupin (Lupinus angustifolius L.). The sensitivity and utility of this method was confirmed by the sequence polymorphism detection based on melting curve profiles in the parental genotypes and progeny of the narrow-leafed lupin mapping population. Application of different approaches, including amplicon size and a simulated heterozygote analysis, has allowed for successful genetic mapping of 16 new STS markers in the narrow-leafed lupin genome.
Zhang, Xiaomei; Zhou, Tingting; Yu, Wenjing; Ai, Jinxia; Wang, Xuesong; Gao, Lijun; Yuan, Guangxin; Li, Mingcheng
2018-01-01
We developed a kind of Zaocys dhumnades DNA test kit and it's indexes including specificity, sensitivity and stability were evaluated and compared with the method recorded in Chinese Pharmacopoeia (2010 edition). The bioinformatics technology was used to design primers, sequencing and blast, in conjunction with PCR technology based on the characteristics of Z. dhumnades cytochrome b (Cyt b) gene. The efficiency of nucleic acid extraction by the kit was done in accordance with Pharmacopoeia method. The kit stability results proved effective after repeated freezing and thawing 20 times. The sensitivity results indicated that the lowest amount detected by the kit was 0. 025 g of each specimen. The specificity test of the kit was 100% specific. All repeatability tests indicated the same results when conducted three times. Compared with the method recorded in Chinese Pharmacopoeia, the PCR-based assay kit by our team developed is accurate, effective in identification of Z. dhumnades, it is simple and fast, demonstrating a broad prospect in quality inspection of Z. dhumnades in the future.
Facile fabrication of a well-ordered porous Cu-doped SnO2 thin film for H2S sensing.
Zhang, Shumin; Zhang, Pingping; Wang, Yun; Ma, Yanyun; Zhong, Jun; Sun, Xuhui
2014-09-10
Well-ordered Cu-doped and undoped SnO2 porous thin films with large specific surface areas have been fabricated on a desired substrate using a self-assembled soft template combined with simple physical cosputtering deposition. The Cu-doped SnO2 porous film gas sensor shows a significant enhancement in its sensing performance, including a high sensitivity, selectivity, and a fast response and recovery time. The sensitivity of the Cu-doped SnO2 porous sensor is 1 order of magnitude higher than that of the undoped SnO2 sensor, with average response and recovery times to 100 ppm of H2S of ∼ 10.1 and ∼ 42.4 s, respectively, at the optimal operating temperature of 180 °C. The well-defined porous sensors fabricated by the method also exhibit high reproducibility because of the accurately controlled fabrication process. The facile process can be easily extended to the fabrication of other semiconductor oxide gas sensors with easy doping and multilayer porous nanostructure for practical sensing applications.
Micropatterned Pyramidal Ionic Gels for Sensing Broad-Range Pressures with High Sensitivity.
Cho, Sung Hwan; Lee, Seung Won; Yu, Seunggun; Kim, Hyeohn; Chang, Sooho; Kang, Donyoung; Hwang, Ihn; Kang, Han Sol; Jeong, Beomjin; Kim, Eui Hyuk; Cho, Suk Man; Kim, Kang Lib; Lee, Hyungsuk; Shim, Wooyoung; Park, Cheolmin
2017-03-22
The development of pressure sensors that are effective over a broad range of pressures is crucial for the future development of electronic skin applicable to the detection of a wide pressure range from acoustic wave to dynamic human motion. Here, we present flexible capacitive pressure sensors that incorporate micropatterned pyramidal ionic gels to enable ultrasensitive pressure detection. Our devices show superior pressure-sensing performance, with a broad sensing range from a few pascals up to 50 kPa, with fast response times of <20 ms and a low operating voltage of 0.25 V. Since high-dielectric-constant ionic gels were employed as constituent sensing materials, an unprecedented sensitivity of 41 kPa -1 in the low-pressure regime of <400 Pa could be realized in the context of a metal-insulator-metal platform. This broad-range capacitive pressure sensor allows for the efficient detection of pressure from a variety of sources, including sound waves, a lightweight object, jugular venous pulses, radial artery pulses, and human finger touch. This platform offers a simple, robust approach to low-cost, scalable device design, enabling practical applications of electronic skin.
Liu, Zhongyuan; Dong, Zhijun; Liu, Dongyan
2016-07-01
Blooms of the harmful jellyfish Cyanea nozakii, which are a severe nuisance to fisheries and tourisms, frequently occur in the northern East China Sea, Yellow Sea, and Bohai Sea. To provide early warning of this species, a simple and effective molecular method for identifying C. nozakii was developed using the loop-mediated isothermal amplification method (LAMP). The LAMP assay is highly specific and uses a set of four primers that target six different regions on the mitochondrial cytochrome c oxidase subunit I (COI) gene of C. nozakii. The amplification conditions, including the dNTP and betaine concentrations, the inner primer to outer primer concentration ratio, reaction time and temperature, were optimized. The LAMP assay amplified DNA extracted from tissue samples of C. nozakii but did not amplify DNA from other common scyphozoans and hydrozoans collected in the same region. In addition, the LAMP assay was more sensitive than conventional PCR. Therefore, the established LAMP assay is a sensitive, specific, fast, and easily performed method for detection of C. nozakii at different stages in their life cycle.
Mekuria, Tefera A; Zhang, Shulu; Eastwell, Kenneth C
2014-09-01
Little cherry virus 2 (LChV2) (genus Ampelovirus) is the primary causal agent of little cherry disease (LCD) in sweet cherry (Prunus avium) in North America and other parts of the world. This mealybug-transmitted virus does not induce significant foliar symptoms in most sweet cherry cultivars, but does cause virus-infected trees to yield unevenly ripened small fruits with poor flavor. Most fruits from infected trees are unmarketable. In the present study, an isothermal reverse transcription-recombinase polymerase amplification (RT-RPA) technique was developed using LChV2 coat protein specific primers and probe. Detection of terminally labeled amplicons was achieved with a high affinity lateral flow strip. The RT-RPA is confirmed to be simple, fast, and specific. In comparison, although it retains the sensitivity of RT-PCR, it is a more cost-effective procedure. RT-RPA will be a very useful tool for detecting LChV2 from crude extracts in any growth stage of sweet cherry from field samples. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
Saunders, Luke J; Russell, Richard A; Crabb, David P
2015-01-01
Swedish Interactive Thresholding Algorithm (SITA) testing strategies for the Humphrey Field Analyzer have become a clinical standard. Measurements from SITA Fast are thought to be more variable than SITA Standard, yet some clinics routinely use SITA Fast because it is quicker. To examine the measurement precision of the 2 SITA strategies across a range of sensitivities using a large number of visual field (VF) series from 4 glaucoma clinics in England. Retrospective cohort study at Moorfields Eye Hospital in London, England; Gloucestershire Eye Unit at Cheltenham General Hospital; Queen Alexandra Hospital in Portsmouth, England; and the Calderdale and Huddersfield National Health Service Foundation Trust that included 66,974 Humphrey 24-2 SITA Standard VFs (10,124 eyes) and 19,819 Humphrey 24-2 SITA Fast VFs (3654 eyes) recorded between May 20, 1997, and September 20, 2012. Pointwise ordinary least squares linear regression of measured sensitivity over time was conducted using VF series of 1 random eye from each patient. Residuals from the regression were pooled according to fitted sensitivities. For each sensitivity (decibel) level, the standard deviation of the residuals was used to estimate measurement precision and were compared for SITA Standard and SITA Fast. Simulations of progression from different VF baselines were used to evaluate how different levels of precision would affect time to detect VF progression. Median years required to detect progression. Median (interquartile range) patient age, follow-up, and series lengths for SITA Standard were 64 (53-72) years, 6.0 (4.0-8.5) years, and 6 (4-8) VFs, respectively; for SITA Fast, medians (interquartile range) were 70 (61-78) years, 5.1 (3.2-7.3) years, and 5 (4-6) VFs. Measurement precision worsened as sensitivity decreased for both test strategies. In the 20 to 5 dB range, SITA Fast was less precise than SITA Standard; this difference was largest between 15 to 10 dB, where variability in both methods peaked. Translated to median time to detection, differences in measurement precision were negligible, suggesting minimal effects on time to detect progression. Although SITA Standard is a more precise testing algorithm than SITA Fast at lower VF sensitivities, it is unlikely to make a sizeable difference to improving the time to detect VF progression.
Galbiati, Silvia; Monguzzi, Alessandra; Damin, Francesco; Soriani, Nadia; Passiu, Marianna; Castellani, Carlo; Natacci, Federica; Curcio, Cristina; Seia, Manuela; Lalatta, Faustina; Chiari, Marcella; Ferrari, Maurizio; Cremonesi, Laura
2016-07-01
Until now, non-invasive prenatal diagnosis of genetic diseases found only limited routine applications. In autosomal recessive diseases, it can be used to determine the carrier status of the fetus through the detection of a paternally inherited disease allele in cases where maternal and paternal mutated alleles differ. Conditions for non-invasive identification of fetal paternally inherited mutations in maternal plasma were developed by two independent approaches: coamplification at lower denaturation temperature-PCR (COLD-PCR) and highly sensitive microarrays. Assays were designed for identifying 14 mutations, 7 causing β-thalassaemia and 7 cystic fibrosis. In total, 87 non-invasive prenatal diagnoses were performed by COLD-PCR in 75 couples at risk for β-thalassaemia and 12 for cystic fibrosis. First, to identify the more appropriate methodology for the analysis of minority mutated fetal alleles in maternal plasma, both fast and full COLD-PCR protocols were developed for the most common Italian β-thalassaemia Cd39 and IVSI.110 mutations. In 5 out of 31 samples, no enrichment was obtained with the fast protocol, while full COLD-PCR provided the correct fetal genotypes. Thus, full COLD-PCR protocols were developed for all the remaining mutations and all analyses confirmed the fetal genotypes obtained by invasive prenatal diagnosis. Microarray analysis was performed on 40 samples from 28 couples at risk for β-thalassaemia and 12 for cystic fibrosis. Results were in complete concordance with those obtained by both COLD-PCR and invasive procedures. COLD-PCR and microarray approaches are not expensive, simple to handle, fast and can be easily set up in specialised clinical laboratories where prenatal diagnosis is routinely performed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Ortelli, Didier; Edder, Patrick; Cognard, Emmanuelle; Jan, Philippe
2008-06-09
Cyanobacteria, commonly called "blue-green algae", may accumulate in surface water supplies as "blooms" and may concentrate on the surface as blue-green "scums". Some species of cyanobacteria produce toxins and are of relevance to water supplies and to microalgae dietary supplements. To ensure the safety of drinking water and blue-green algae products, analyses are the only way to determine the presence or absence of toxins. This paper shows the use of ultra performance liquid chromatography (UPLC) coupled to orthogonal acceleration time of flight (TOF) mass spectrometry for the detection and quantitation of microcystins. The method presented is very sensitive, simple, fast, robust and did not require fastidious clean-up step. Limits of detection of 0.1 microg L(-1) in water and 0.1-0.2 microg g(-1) in microalgae samples were achieved. Method performances were satisfactory and appropriate for monitoring of water and dietary supplements. The method was applied in routine to samples taken from Swiss market or buy on internet website. Among 19 samples, six showed the presence of microcystins LR and LA at harmful levels.
A simple procedure for γ- γ lifetime measurements using multi-element fast-timing arrays
NASA Astrophysics Data System (ADS)
Régis, J.-M.; Dannhoff, M.; Jolie, J.
2018-07-01
The lifetimes of nuclear excited states are important observables in nuclear physics. Their precise measurement is of key importance for developing and testing nuclear models as they are directly linked with the quantum nature of the nuclear system. The γ- γ timing technique represents a direct lifetime determination by means of time-difference measurements between the γ rays which directly feed and decay from a nuclear excited state. Using arrays of very-fast scintillator detectors, picosecond-sensitive time-difference measurements can be performed. We propose to construct a symmetric energy-energy-time cube as is usually done to perform γ- γ coincidence analyses and lifetime determination with high-resolution germanium detectors. By construction, a symmetric mean time-walk characteristics is obtained, that can be precisely determined and used as a single time correction for all the data independently of the detectors. We present the results of timing characteristics measurements of an array with six LaBr3(Ce) detectors, as obtained using a 152Eu point γ-ray source. Compared with a single detector pair, the time resolution of the symmetrised time-difference spectra of the array is nearly unaffected.
Aerial surveillance for gas and liquid hydrocarbon pipelines using a flame ionization detector (FID)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riquetti, P.V.; Fletcher, J.I.; Minty, C.D.
1996-12-31
A novel application for the detection of airborne hydrocarbons has been successfully developed by means of a highly sensitive, fast responding Flame Ionization Detector (FID). The traditional way to monitor pipeline leaks has been by ground crews using specific sensors or by airborne crews highly trained to observe anomalies associated with leaks during periodic surveys of the pipeline right-of-way. The goal has been to detect leaks in a fast and cost effective way before the associated spill becomes a costly and hazardous problem. This paper describes a leak detection system combined with a global positioning system (GPS) and a computerizedmore » data output designed to pinpoint the presence of hydrocarbons in the air space of the pipeline`s right of way. Fixed wing aircraft as well as helicopters have been successfully used as airborne platforms. Natural gas, crude oil and finished products pipelines in Canada and the US have been surveyed using this technology with excellent correlation between the aircraft detection and in situ ground detection. The information obtained is processed with a proprietary software and reduced to simple coordinates. Results are transferred to ground crews to effect the necessary repairs.« less
The Subread aligner: fast, accurate and scalable read mapping by seed-and-vote
Liao, Yang; Smyth, Gordon K.; Shi, Wei
2013-01-01
Read alignment is an ongoing challenge for the analysis of data from sequencing technologies. This article proposes an elegantly simple multi-seed strategy, called seed-and-vote, for mapping reads to a reference genome. The new strategy chooses the mapped genomic location for the read directly from the seeds. It uses a relatively large number of short seeds (called subreads) extracted from each read and allows all the seeds to vote on the optimal location. When the read length is <160 bp, overlapping subreads are used. More conventional alignment algorithms are then used to fill in detailed mismatch and indel information between the subreads that make up the winning voting block. The strategy is fast because the overall genomic location has already been chosen before the detailed alignment is done. It is sensitive because no individual subread is required to map exactly, nor are individual subreads constrained to map close by other subreads. It is accurate because the final location must be supported by several different subreads. The strategy extends easily to find exon junctions, by locating reads that contain sets of subreads mapping to different exons of the same gene. It scales up efficiently for longer reads. PMID:23558742
A Digital Microfluidics Platform for Loop-Mediated Isothermal Amplification Detection
Veigas, Bruno; Águas, Hugo; Fortunato, Elvira; Martins, Rodrigo; Baptista, Pedro Viana; Igreja, Rui
2017-01-01
Digital microfluidics (DMF) arises as the next step in the fast-evolving field of operation platforms for molecular diagnostics. Moreover, isothermal schemes, such as loop-mediated isothermal amplification (LAMP), allow for further simplification of amplification protocols. Integrating DMF with LAMP will be at the core of a new generation of detection devices for effective molecular diagnostics at point-of-care (POC), providing simple, fast, and automated nucleic acid amplification with exceptional integration capabilities. Here, we demonstrate for the first time the role of coupling DMF and LAMP, in a dedicated device that allows straightforward mixing of LAMP reagents and target DNA, as well as optimum temperature control (reaction droplets undergo a temperature variation of just 0.3 °C, for 65 °C at the bottom plate). This device is produced using low-temperature and low-cost production processes, adaptable to disposable and flexible substrates. DMF-LAMP is performed with enhanced sensitivity without compromising reaction efficacy or losing reliability and efficiency, by LAMP-amplifying 0.5 ng/µL of target DNA in just 45 min. Moreover, on-chip LAMP was performed in 1.5 µL, a considerably lower volume than standard bench-top reactions. PMID:29144379
Halbfeld, Christoph; Ebert, Birgitta E.; Blank, Lars M.
2014-01-01
Volatile organic compounds (VOCs) produced during microbial fermentations determine the flavor of fermented food and are of interest for the production of fragrances or food additives. However, the microbial synthesis of these compounds from simple carbon sources has not been well investigated so far. Here, we analyzed the headspace over glucose minimal salt medium cultures of Saccharomyces cerevisiae using multi-capillary column-ion mobility spectrometry (MCC-IMS). The high sensitivity and fast data acquisition of the MCC-IMS enabled online analysis of the fermentation off-gas and 19 specific signals were determined. To four of these volatile compounds, we could assign the metabolites ethanol, 2-pentanone, isobutyric acid, and 2,3-hexanedione by MCC-IMS measurements of pure standards and cross validation with thermal desorption–gas chromatography-mass spectrometry measurements. Despite the huge biochemical knowledge of the biochemistry of the model organism S. cerevisiae, only the biosynthetic pathways for ethanol and isobutyric acid are fully understood, demonstrating the considerable lack of research of volatile metabolites. As monitoring of VOCs produced during microbial fermentations can give valuable insight into the metabolic state of the organism, fast and non-invasive MCC-IMS analyses provide valuable data for process control. PMID:25197771
Michel, K; Michaelis, M; Mazzuoli, G; Mueller, K; Vanden Berghe, P; Schemann, M
2011-12-15
Slow changes in [Ca(2+)](i) reflect increased neuronal activity. Our study demonstrates that single-trial fast [Ca(2+)](i) imaging (≥200 Hz sampling rate) revealed peaks each of which are associated with single spike discharge recorded by consecutive voltage-sensitive dye (VSD) imaging in enteric neurones and nerve fibres. Fast [Ca(2+)](i) imaging also revealed subthreshold fast excitatory postsynaptic potentials. Nicotine-evoked [Ca(2+)](i) peaks were reduced by -conotoxin and blocked by ruthenium red or tetrodotoxin. Fast [Ca(2+)](i) imaging can be used to directly record single action potentials in enteric neurones. [Ca(2+)](i) peaks required opening of voltage-gated sodium and calcium channels as well as Ca(2+) release from intracellular stores.
Peptide-gated ion channels and the simple nervous system of Hydra.
Gründer, Stefan; Assmann, Marc
2015-02-15
Neurons either use electrical or chemical synapses to communicate with each other. Transmitters at chemical synapses are either small molecules or neuropeptides. After binding to their receptors, transmitters elicit postsynaptic potentials, which can either be fast and transient or slow and longer lasting, depending on the type of receptor. Fast transient potentials are mediated by ionotropic receptors and slow long-lasting potentials by metabotropic receptors. Transmitters and receptors are well studied for animals with a complex nervous system such as vertebrates and insects, but much less is known for animals with a simple nervous system like Cnidaria. As cnidarians arose early in animal evolution, nervous systems might have first evolved within this group and the study of neurotransmission in cnidarians might reveal an ancient mechanism of neuronal communication. The simple nervous system of the cnidarian Hydra extensively uses neuropeptides and, recently, we cloned and functionally characterized an ion channel that is directly activated by neuropeptides of the Hydra nervous system. These results demonstrate the existence of peptide-gated ion channels in Hydra, suggesting they mediate fast transmission in its nervous system. As related channels are also present in the genomes of the cnidarian Nematostella, of placozoans and of ctenophores, it should be considered that the early nervous systems of cnidarians and ctenophores have co-opted neuropeptides for fast transmission at chemical synapses. © 2015. Published by The Company of Biologists Ltd.
Decay Time of Cathodoluminescence
ERIC Educational Resources Information Center
Kraftmakher, Yaakov
2009-01-01
Simple measurements of the decay time of cathodoluminescence are described. Cathodoluminescence is used in many devices, including computer monitors, oscilloscopes, radar displays and television tubes. The experimental setup is simple and easy to build. Two oscilloscopes, a function generator, and a fast photodiode are needed for the experiments.…
Gemmink, Anne; Bosma, Madeleen; Kuijpers, Helma J H; Hoeks, Joris; Schaart, Gert; van Zandvoort, Marc A M J; Schrauwen, Patrick; Hesselink, Matthijs K C
2016-05-01
In contrast to insulin-resistant individuals, insulin-sensitive athletes possess high intramyocellular lipid content (IMCL), good mitochondrial function and high perilipin 5 (PLIN5) levels, suggesting a role for PLIN5 in benign IMCL storage. We hypothesised a role for PLIN5 in modulating fasting-mediated insulin resistance. Twelve men were fasted for 60 h, before and after which muscle biopsies were taken and stained for lipid droplets (LDs), PLIN5 and laminin. Confocal microscopy images were analysed for LD size, number, PLIN5 association and subcellular distribution. Fasting elevated IMCL content 2.8-fold and reduced insulin sensitivity (by 55%). Individuals with the most prominent increase in IMCL showed the least reduction in insulin sensitivity (r = 0.657; p = 0.028) and mitochondrial function (r = 0.896; p = 0.006). During fasting, PLIN5 gene expression or PLIN5 protein content in muscle homogenates was unaffected, microscopy analyses revealed that the fraction of PLIN5 associated with LDs (PLIN5+) increased significantly (+26%) upon fasting, suggesting PLIN5 redistribution. The significant increase in LD number (+23%) and size (+23%) upon fasting was entirely accounted for by PLIN5+ LDs, not by LDs devoid of PLIN5. Also the association between IMCL storage capacity and insulin resistance and mitochondrial dysfunction was only apparent for PLIN5+ LDs. Fasting results in subcellular redistribution of PLIN5 and promotes the capacity to store excess fat in larger and more numerous PLIN5-decorated LDs. This associates with blunting of fasting-induced insulin resistance and mitochondrial dysfunction, suggesting a role for PLIN5 in the modulation of fasting-mediated lipotoxicity. trialregister.nl NTR 2042.
Pataky, Z; Golay, A; Laville, M; Disse, E; Mitrakou, A; Guidone, C; Gabriel, R; Bobbioni-Harsch, E
2013-09-01
This was a cross-sectional and longitudinal study of factors contributing to the number of cardiometabolic risk factors, common carotid artery intima-media thickness (CCA-IMT) and R-R interval in clinically healthy subjects without diabetes. Anthropometric and cardiometabolic parameters were measured in the Relationship between Insulin Sensitivity and Cardiovascular Disease (RISC) Study cohort at baseline (n=1211) and 3years later (n=974). At baseline, insulin sensitivity was assessed by the euglycaemic clamp technique. The CCA-IMT was echographically measured and the R-R interval was electrocardiographically evaluated at baseline and at the 3-year follow-up. Higher baseline BMI, fasting insulin and tobacco use as well as greater changes in BMI and fasting insulin but lower adiponectin levels, were associated with a greater number of cardiometabolic risk factors at the 3-year follow-up independently of insulin sensitivity (all P<0.02). The CCA-IMT increased with the number of cardiometabolic risk factors (P=0.008), but was not related to fasting insulin, whereas higher fasting insulinaemia and its 3-year changes were significantly associated with a smaller R-R interval (P=0.005 and P=0.002, respectively). These relationships were independent of baseline age, gender, BMI, adiponectin, insulin sensitivity, tobacco use and physical activity. In clinically healthy subjects, fasting insulinaemia, adiponectin and lifestyle parameters are related to the presence of one or two cardiometabolic risk factors before criteria for the metabolic syndrome are met. These results underline the importance of fasting insulinaemia as an independent cardiometabolic risk factor at an early stage of disease development in a healthy general population. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Bi-functional ion exchangers for enhanced performance of dye-sensitized solar cells.
Kong, Eui-Hyun; Chang, Yong-June; Lim, Jongchul; Kim, Back-Hyun; Lee, Jung-Hoon; Kwon, Do-Kyun; Park, Taiho; Jang, Hyun Myung
2013-07-28
Ion exchange using aerosol OT (AOT) offers dye adsorption twice as fast as known methods. Moreover, it suppresses the dye-agglomeration that may cause insufficient dye-coverage on the photoelectrode surface. Consequently, its dual function of fast dye-loading and higher dye-coverage significantly improves the power conversion efficiency of dye-sensitized solar cells.
Kim, Kang-Hyun; Hong, Soon Kyu; Jang, Nam-Su; Ha, Sung-Hun; Lee, Hyung Woo; Kim, Jong-Man
2017-05-24
Wearable pressure sensors are crucial building blocks for potential applications in real-time health monitoring, artificial electronic skins, and human-to-machine interfaces. Here we present a highly sensitive, simple-architectured wearable resistive pressure sensor based on highly compliant yet robust carbon composite conductors made of a vertically aligned carbon nanotube (VACNT) forest embedded in a polydimethylsiloxane (PDMS) matrix with irregular surface morphology. A roughened surface of the VACNT/PDMS composite conductor is simply formed using a sandblasted silicon master in a low-cost and potentially scalable manner and plays an important role in improving the sensitivity of resistive pressure sensor. After assembling two of the roughened composite conductors, our sensor shows considerable pressure sensitivity of ∼0.3 kPa -1 up to 0.7 kPa as well as stable steady-state responses under various pressures, a wide detectable range of up to 5 kPa before saturation, a relatively fast response time of ∼162 ms, and good reproducibility over 5000 cycles of pressure loading/unloading. The fabricated pressure sensor can be used to detect a wide range of human motions ranging from subtle blood pulses to dynamic joint movements, and it can also be used to map spatial pressure distribution in a multipixel platform (in a 4 × 4 pixel array).
Lanini, Juliana; Galduróz, José Carlos Fernandes; Pompéia, Sabine
2016-01-01
Caffeine is widely used, often consumed with food, and improves simple and complex/executive attention under fasting conditions. We investigated whether these cognitive effects are observed when personalized habitual doses of caffeine are ingested by caffeine consumers, whether they are influenced by nutriments and if various executive domains are susceptible to improvement. This was a double-blind, placebo-controlled study including 60 young, healthy, rested males randomly assigned to one of four treatments: placebo fasting, caffeine fasting, placebo meal and caffeine meal. Caffeine doses were individualized for each participant based on their self-reported caffeine consumption at the time of testing (morning). The test battery included measures of simple and sustained attention, executive domains (inhibiting, updating, shifting, dual tasking, planning and accessing long-term memory), control measures of subjective alterations, glucose and insulin levels, skin conductance, heart rate and pupil dilation. Regardless of meal intake, acute habitual doses of caffeine decreased fatigue, and improved simple and sustained attention and executive updating. This executive effect was not secondary to the habitual weekly dose consumed, changes in simple and sustained attention, mood, meal ingestion and increases in cognitive effort. We conclude that the morning caffeine "fix" has positive attentional effects and selectively improved executive updating whether or not caffeine is consumed with food. Copyright © 2015 John Wiley & Sons, Ltd.
Pirich, Cleverton Luiz; de Freitas, Rilton Alves; Torresi, Roberto Manuel; Picheth, Guilherme Fadel; Sierakowski, Maria Rita
2017-06-15
Low-cost piezoelectric devices, such as simple frequency monitoring quartz crystal microbalance (QCM) devices, have good clinical utility as fast diagnostic tools for the detection of several diseases. However, unspecific antigen recognition, poor molecular probe adsorption and the need for sample dilution are still common drawbacks that hinder their use in routine diagnosis. In this work, piezoelectric sensors were previously coated with thin films of bacterial cellulose nanocrystals (CN) to provide a more sensitive and adapted interface for the attachment of monoclonal immunoglobulin G (IgGNS1) and to favor specific detection of non-structural protein 1 (NS1) of dengue fever. The assembly of the immunochip surface was analyzed by atomic force microscopy (AFM) and the NS1 detection was followed by quartz crystal microbalance with (QCM-D) and without energy dissipation monitoring (QCM). The CN surface was able to immobilize 2.30±0.5mgm -2 of IgGNS1, as confirmed by AFM topography and phase images along with QCM-D. The system was able to detect the NS1 protein in serum with only 10-fold dilution in the range of 0.01-10µgmL -1 by both QCM and QCM-D. The limits of detection of the two devices were 0.1μgmL -1 for QCM-D and 0.32μgmL -1 for QCM. As a result, QCM-D and QCM apparatuses can be used to follow NS1 recognition and have good potential for more sensitive, fast and/or less expensive diagnostic assays for dengue. Copyright © 2017 Elsevier B.V. All rights reserved.
Wu, Di; Kimura, Fuminori; Takashima, Akiko; Shimizu, Yoshihiko; Takebayashi, Akie; Kita, Nobuyuki; Zhang, Guangmei; Murakami, Takashi
2013-05-01
Polycystic ovary syndrome (PCOS) is one of major causes of irregular menstruation. It is defined as a condition involving the combination of hyperandrogenism and chronic oligomenorrhea or anovulation, and is thought to have a variety of etiologies. Insulin resistance (impaired insulin sensitivity) has been suggested to be one of the etiologies of PCOS. PCOS patients often need to take medication to treat anovulation and infertility. Therefore, it would be beneficial to patients if simple non-pharmacological treatments can be developed. Recently the efficacy of vinegar to improve insulin resistance has been reported. To study the effect of vinegar on metabolic and hormonal indices and ovulatory function in PCOS, seven patients seeking a non-pharmacological treatment for PCOS took a beverage containing 15 g of apple vinegar daily for 90 to 110 days. Ovulation, the menstrual interval, fasting serum glucose level, fasting serum insulin level, luteinizing hormone (LH), follicle stimulating hormone (FSH), and testosterone were compared before and after intake of the vinegar beverage. Intake of the vinegar beverage resulted in a decrease of the homeostasis model assessment insulin resistance index (HOMA-R) in six patients, as well as a decrease of the LH/FSH ratio in five of seven patients. Ovulatory menstruation was observed within 40 day in four of seven patients. These findings suggest the possibility of vinegar to restore ovulatory function through improving insulin sensitivity in PCOS patients, thus, avoiding pharmacological treatment. Intake of vinegar might reduce medical cost and treatment time for insulin resistance, anovulation, and infertility in patients with PCOS.
COLD-PCR enriches low-level variant DNA sequences and increases the sensitivity of genetic testing.
Castellanos-Rizaldos, Elena; Milbury, Coren A; Guha, Minakshi; Makrigiorgos, G Mike
2014-01-01
Detection of low-level mutations is important for cancer biomarker and therapy targets discovery, but reliable detection remains a technical challenge. The newly developed method of CO-amplification at Lower Denaturation temperature PCR (COLD-PCR) helps to circumvent this issue. This PCR-based technology preferentially enriches minor known or unknown variants present in samples with a high background of wild type DNA which often hampers the accurate identification of these minority alleles. This is a simple process that consists of lowering the temperature at the denaturation step during the PCR-cycling protocol (critical denaturation temperature, T c) and inducing DNA heteroduplexing during an intermediate step. COLD-PCR in its simplest forms does not need additional reagents or specific instrumentation and thus, can easily replace conventional PCR and at the same time improve the mutation detection sensitivity limit of downstream technologies. COLD-PCR can be applied in two basic formats: fast-COLD-PCR that can enrich T m-reducing mutations and full-COLD-PCR that can enrich all mutations, though it requires an intermediate cross-hybridization step that lengthens the thermocycling program. An improved version of full-COLD-PCR (improved and complete enrichment, ice-COLD-PCR) has also been described. Finally, most recently, we developed yet another form of COLD-PCR, temperature-tolerant-COLD-PCR, which gradually increases the denaturation temperature during the COLD-PCR reaction, enriching diverse targets using a single cycling program. This report describes practical considerations for application of fast-, full-, ice-, and temperature-tolerant-COLD-PCR for enrichment of mutations prior to downstream screening.
NASA Astrophysics Data System (ADS)
Toramatsu, Chie; Inaniwa, Taku
2016-12-01
In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. The sensitivity of a PBS plan to lateral tissue heterogeneities can be reduced by selecting appropriate beam angles. The purpose of this study is to develop a fast and accurate method of beam angle selection for PBS. The lateral tissue heterogeneity surrounding the path of the pencil beams at a given angle was quantified with the heterogeneity number representing the variation of the Bragg peak depth across the cross section of the beams using the stopping power ratio of body tissues with respect to water. To shorten the computation time, one-dimensional dose optimization was conducted along the central axis of the pencil beams as they were directed by the scanning magnets. The heterogeneity numbers were derived for all possible beam angles for treatment. The angles leading to the minimum mean heterogeneity number were selected as the optimal beam angle. Three clinical cases of head and neck cancer were used to evaluate the developed method. Dose distributions and their robustness to setup and range errors were evaluated for all tested angles, and their relation to the heterogeneity numbers was investigated. The mean heterogeneity number varied from 1.2 mm-10.6 mm in the evaluated cases. By selecting a field with a low mean heterogeneity number, target dose coverage and robustness against setup and range errors were improved. The developed method is simple, fast, accurate and applicable for beam angle selection in charged particle therapy with PBS.
Martewicz, Sebastian; Gabrel, Giulia; Campesan, Marika; Canton, Marcella; Di Lisa, Fabio; Elvassore, Nicola
2018-05-01
Analyses of cellular responses to fast oxygen dynamics are challenging and require ad hoc technological solutions, especially when decoupling from liquid media composition is required. In this work, we present a microfluidic device specifically designed for culture analyses with high resolution and magnification objectives, providing full optical access to the cell culture chamber. This feature allows fluorescence-based assays, photoactivated surface chemistry, and live cell imaging under tightly controlled pO 2 environments. The device has a simple design, accommodates three independent cell cultures, and can be employed by users with basic cell culture training in studies requiring fast oxygen dynamics, defined media composition, and in-line data acquisition with optical molecular probes. We apply this technology to produce an oxygen/glucose deprived (OGD) environment and analyze cell mortality in murine and human cardiac cultures. Neonatal rat ventricular cardiomyocytes show an OGD time-dependent sensitivity, resulting in a robust and reproducible 66 ± 5% death rate after 3 h of stress. Applying an equivalent stress to human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs) provides direct experimental evidence for fetal-like OGD-resistant phenotype. Investigation on the nature of such phenotype exposed large glycogen deposits. We propose a culture strategy aimed at depleting these intracellular energy stores and concurrently activate positive regulation of aerobic metabolic molecular markers. The observed process, however, is not sufficient to induce an OGD-sensitive phenotype in hiPS-CMs, highlighting defective development of mature aerobic metabolism in vitro.
Do we really rely on fast for decision-making in the management of blunt abdominal trauma?
Carter, Jeffrey W; Falco, Mark H; Chopko, Michael S; Flynn, William J; Wiles Iii, Charles E; Guo, Weidun Alan
2015-05-01
The Focused Assessment with Sonography in Trauma examination (FAST) is currently taught and recommended in the ATLS(®), often as an addendum to the primary survey for patients with blunt abdominal trauma. Although it is non-invasive and rapidly performed at bedside, the utility of FAST in blunt abdominal trauma has been questioned. We designed this study to examine our hypothesis that FAST is not an efficacious screening tool for identifying intra-abdominal injuries. We performed a retrospective chart review of all patients with confirmatory diagnosis of blunt abdominal injuries with CT and/or laparotomy for a period of 1.5 years (from 7/2009 to 11/2010). FAST was performed by ED residents and considered positive when free intra-abdominal fluid was visualized. Abdominal CT, or exploratory laparotomy findings were used as confirmation of intra-abdominal injury. A total of 1671 blunt trauma patients were admitted to and evaluated in the Emergency Department during a 1½ year period and 146 patients were confirmed intra-abdominal injuries by CT and/or laparotomy. Intraoperative findings include injuries to the liver, spleen, kidneys, and bowels. In 114 hemodynamically stable patients, FAST was positive in 25 patients, with a sensitivity of 22%. In 32 hemodynamically unstable patients, FAST was positive in 9 patients, with a sensitivity of 28%. A free peritoneal fluid and splenic injury are associated with a positive FAST on univariate analysis, and are the independent predictors for a positive FAST on multiple logistic regression. FAST has a very low sensitivity in detecting blunt intraabdominal injury. In hemodynamically stable patients, a negative FAST without a CT may result in missed intra-abdominal injuries. In hemodynamically unstable blunt trauma patients, with clear physical findings on examination, the decision for exploratory laparotomy should not be distracted by a negative FAST. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ben-Ishay, Offir; Daoud, Mai; Peled, Zvi; Brauner, Eran; Bahouth, Hany; Kluger, Yoram
2015-01-01
In pediatric care, the role of focused abdominal sonography in trauma (FAST) remains ill defined. The objective of this study was to assess the sensitivity and specificity of FAST for detecting free peritoneal fluid in children. The trauma registry of a single level I pediatric trauma center was queried for the results of FAST examination of consecutive pediatric (<18 years) blunt trauma patients over a period of 36 months, from January 2010 to December 2012. Demographics, type of injuries, FAST results, computerized tomography (CT) results, and operative findings were reviewed. During the study period, 543 injured pediatric patients (mean age 8.2 ± 5 years) underwent FAST examinations. In 95 (17.5 %) FAST was positive for free peritoneal fluid. CT examination was performed in 219 (40.3 %) children. Positive FAST examination was confirmed by CT scan in 61/73 (83.6 %). CT detected intra-peritoneal fluid in 62/448 (13.8 %) of the patients with negative FAST results. These findings correspond to a sensitivity of 50 %, specificity of 88 %, positive predictive value (PPV) of 84 %, and a negative predictive value (NPV) of 58 %. In patients who had negative FAST results and no CT examination (302), no missed abdominal injury was detected on clinical ground. FAST examination in the young age group (<2 years) yielded lower sensitivity and specificity (36 and 78 % respectively) with a PPV of only 50 %. This study shows that although a positive FAST evaluation does not necessarily correlate with an IAI, a negative one strongly suggests the absence of an IAI, with a high NPV. These findings are emphasized in the analysis of the subgroup of children less than 2 years of age. FAST examination tempered with sound clinical judgment seems to be an effective tool to discriminate injured children in need of further imaging evaluation.
Two-Photon Imaging with Diffractive Optical Elements
Watson, Brendon O.; Nikolenko, Volodymyr; Yuste, Rafael
2009-01-01
Two-photon imaging has become a useful tool for optical monitoring of neural circuits, but it requires high laser power and serial scanning of each pixel in a sample. This results in slow imaging rates, limiting the measurements of fast signals such as neuronal activity. To improve the speed and signal-to-noise ratio of two-photon imaging, we introduce a simple modification of a two-photon microscope, using a diffractive optical element (DOE) which splits the laser beam into several beamlets that can simultaneously scan the sample. We demonstrate the advantages of DOE scanning by enhancing the speed and sensitivity of two-photon calcium imaging of action potentials in neurons from neocortical brain slices. DOE scanning can easily improve the detection of time-varying signals in two-photon and other non-linear microscopic techniques. PMID:19636390
Rapid Design of Gravity Assist Trajectories
NASA Technical Reports Server (NTRS)
Carrico, J.; Hooper, H. L.; Roszman, L.; Gramling, C.
1991-01-01
Several International Solar Terrestrial Physics (ISTP) missions require the design of complex gravity assisted trajectories in order to investigate the interaction of the solar wind with the Earth's magnetic field. These trajectories present a formidable trajectory design and optimization problem. The philosophy and methodology that enable an analyst to design and analyse such trajectories are discussed. The so called 'floating end point' targeting, which allows the inherently nonlinear multiple body problem to be solved with simple linear techniques, is described. The combination of floating end point targeting with analytic approximations with a Newton method targeter to achieve trajectory design goals quickly, even for the very sensitive double lunar swingby trajectories used by the ISTP missions, is demonstrated. A multiconic orbit integration scheme allows fast and accurate orbit propagation. A prototype software tool, Swingby, built for trajectory design and launch window analysis, is described.
Magnetically-focusing biochip structures for high-speed active biosensing with improved selectivity.
Yoo, Haneul; Lee, Dong Jun; Kim, Daesan; Park, Juhun; Chen, Xing; Hong, Seunghun
2018-06-29
We report a magnetically-focusing biochip structure enabling a single layered magnetic trap-and-release cycle for biosensors with an improved detection speed and selectivity. Here, magnetic beads functionalized with specific receptor molecules were utilized to trap target molecules in a solution and transport actively to and away from the sensor surfaces to enhance the detection speed and reduce the non-specific bindings, respectively. Using our method, we demonstrated the high speed detection of IL-13 antigens with the improved detection speed by more than an order of magnitude. Furthermore, the release step in our method was found to reduce the non-specific bindings and improve the selectivity and sensitivity of biosensors. This method is a simple but powerful strategy and should open up various applications such as ultra-fast biosensors for point-of-care services.
Tashkhourian, Javad; Absalan, Ghodratollah; Jafari, Marzieh; Zare, Saber
2016-01-05
A rapid, simple and inexpensive spectrofluorimetric sensor for determination of doxycycline based on its interaction with thioglycolic acid-capped cadmium telluride quantum dots (TGA/CdTe QDs) has been developed. Under the optimum experimental conditions, the sensor exhibited a fast response time of <10s. The results revealed that doxycycline could quench the fluorescence of TGA/CdTe QDs via electron transfer from the QDs to doxycycline through a dynamic quenching mechanism. The sensor permitted determination of doxycycline in a concentration range of 1.9×10(-6)-6.1×10(-5)molL(-1) with a detection limit of 1.1×10(-7)molL(-1). The sensor was applied for determination of doxycycline in honey and human serum samples. Copyright © 2015 Elsevier B.V. All rights reserved.
PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles.
Luo, Chunxiong; Fu, Qiang; Li, Hao; Xu, Luping; Sun, Manhui; Ouyang, Qi; Chen, Yong; Ji, Hang
2005-07-01
A simple but highly specific immunoassay system for goat anti-human IgG has been developed using gold nanoparticles and microfluidic techniques. The assay is based on the deposition of gold nanoparticles that are coated with protein antigens in the presence of their corresponding antibodies to microfluidic channel surface. The effects of time accumulation, the flow velocity, and the concentration of antibodies to the red light absorption percentage (RAP) of deposition were investigated with an ordinary optical microscope. By controlling the reaction time and flow velocity, a dynamic range of 3 orders of magnitude and a detection sensitivity of 10 ng ml(-1) of goat anti-human IgG were achieved. Because of its simplicity and flexibility, this new technique should be useful for fast, highthroughput screening of antibodies in clinical diagnostic applications.
Implosion-driven technique to create fast shockwaves in high-density gas
NASA Astrophysics Data System (ADS)
Serge, Matthew; Loiseau, Jason; Huneault, Justin; Szirti, Daniel; Higgins, Andrew; Tanguay, Vincent
2012-03-01
Pressurized tubes surrounded by either one or two layers (separated by a secondary tube) of sensitized nitromethane and encased in a thick-walled tube (the tamper) were imploded. The distance between the detonation wave in the explosive and shock wave in the innermost tube were measured (the standoff). A simple model based on hoop stress and acoustic interactions between the tubing was developed and used to predict the standoff distance. At low initial pressures (on the order of 7MPa), results indicate that the secondary tube and two layers of explosive did not prove to significantly increase the standoff. However, at higher pressures (on the order of 10 MPa), standoff was noticeably greater when the secondary tube was inserted between the pressurized tube and the tamper. The measured values are in reasonable agreement with the predictions of the model.
Dumont, Elodie; De Bleye, Charlotte; Sacré, Pierre-Yves; Netchacovitch, Lauranne; Hubert, Philippe; Ziemons, Eric
2016-05-01
Over recent decades, spreading environmental concern entailed the expansion of green chemistry analytical tools. Vibrational spectroscopy, belonging to this class of analytical tool, is particularly interesting taking into account its numerous advantages such as fast data acquisition and no sample preparation. In this context, near-infrared, Raman and mainly surface-enhanced Raman spectroscopy (SERS) have thus gained interest in many fields including bioanalysis. The two former techniques only ensure the analysis of concentrated compounds in simple matrices, whereas the emergence of SERS improved the performances of vibrational spectroscopy to very sensitive and selective analyses. Complex SERS substrates were also developed enabling biomarker measurements, paving the way for SERS immunoassays. Therefore, in this paper, the strengths and weaknesses of these techniques will be highlighted with a focus on recent progress.
Magnetically-focusing biochip structures for high-speed active biosensing with improved selectivity
NASA Astrophysics Data System (ADS)
Yoo, Haneul; Lee, Dong Jun; Kim, Daesan; Park, Juhun; Chen, Xing; Hong, Seunghun
2018-06-01
We report a magnetically-focusing biochip structure enabling a single layered magnetic trap-and-release cycle for biosensors with an improved detection speed and selectivity. Here, magnetic beads functionalized with specific receptor molecules were utilized to trap target molecules in a solution and transport actively to and away from the sensor surfaces to enhance the detection speed and reduce the non-specific bindings, respectively. Using our method, we demonstrated the high speed detection of IL-13 antigens with the improved detection speed by more than an order of magnitude. Furthermore, the release step in our method was found to reduce the non-specific bindings and improve the selectivity and sensitivity of biosensors. This method is a simple but powerful strategy and should open up various applications such as ultra-fast biosensors for point-of-care services.
Spectrophotometry of cerebrospinal fluid in subacute and chronic subdural haematomas
Kjellin, K. G.; Steiner, L.
1974-01-01
Spectrophotometric examinations were performed on cerebrospinal and subdural fluids in subacute (five patients) and chronic (20 patients) subdural haematomas, with special reference to the diagnostic aid of CSF spectrophotometry. Spectrophotometric xanthochromia of haemorrhagic origin was found in all CSFs examined, while definite visible xanthochromia was observed in only 28% and the CSF was judged as colourless in 52% of those cases. Characteristic bleeding patterns were found spectrophotometrically in all the 20 CSFs examined within 24 hours after lumbar puncture, haematoma patterns being detected in 90-95% of the cases. In many cases the electrophoretically separated protein fractions of CSF and subdural fluids were spectrophotometrically examined. In conclusion, CSF spectrophotometry is a simple, fast, and extremely sensitive method, which in our opinion should be used routinely in the diagnosis of suspected subdural haematomas, if lumbar puncture is not contraindicated. PMID:4140892
Background-Oriented Schlieren (BOS) for Scramjet Inlet-isolator Investigation
NASA Astrophysics Data System (ADS)
Che Idris, Azam; Rashdan Saad, Mohd; Hing Lo, Kin; Kontis, Konstantinos
2018-05-01
Background-oriented Schlieren (BOS) technique is a recently invented non-intrusive flow diagnostic method which has yet to be fully explored in its capabilities. In this paper, BOS technique has been applied for investigating the general flow field characteristics inside a generic scramjet inlet-isolator with Mach 5 flow. The difficulty in finding the delicate balance between measurement sensitivity and measurement area image focusing has been demonstrated. The differences between direct cross-correlation (DCC) and Fast Fourier Transform (FFT) raw data processing algorithm have also been demonstrated. As an exploratory study of BOS capability, this paper found that BOS is simple yet robust enough to be used to visualize complex flow in a scramjet inlet in hypersonic flow. However, in this case its quantitative data can be strongly affected by 3-dimensionality thus obscuring the density value with significant errors.
Brufani, Claudia; Ciampalini, Paolo; Grossi, Armando; Fiori, Rossana; Fintini, Danilo; Tozzi, Alberto; Cappa, Marco; Barbetti, Fabrizio
2010-02-01
Childhood obesity is epidemic in developed countries and is accompanied by an increase in the prevalence of type 2 diabetes (T2DM). Establish prevalence of glucose metabolism alterations in a large sample of overweight/obese children and adolescents from Central Italy. The study group included 510 overweight/obese subjects (3-18 yr). Oral glucose tolerance test (OGTT) was performed with glucose and insulin determination. Homeostatic model assessment of insulin resistance (HOMA-IR) and insulin sensitivity index (ISI) were derived from fasting and OGTT measurements. Beta-cell function was estimated by insulinogenic index. Fat mass was measured by dual-energy x-ray absorptiometry. Glucose metabolism alterations were detected in 12.4% of patients. Impaired glucose tolerance (IGT) was the most frequent alteration (11.2%), with a higher prevalence in adolescents than in children (14.8 vs. 4.1%, p < 0.001); silent T2DM was identified in two adolescents (0.4%). HOMA-IR and glucose-stimulated insulin levels were higher in patients with IGT than individuals with normal glucose tolerance (HOMA-IR = 4.4 +/- 2.5 vs. 3.4 +/- 2.3, p = 0.001). Fat mass percentage and insulinogenic index were not different between the two groups. In multivariate analysis, age, fasting glucose, and insulin resistance influenced independently plasma glucose at 120 min of OGTT. Individuals with combined impaired fasting glucose/IGT (IFG/IGT) and T2DM were older and had reduced plasma insulin values at OGTT when compared to patients with simple IGT. Glucose metabolism alterations are frequently found among children and adolescents with overweight/obesity from Central Italy. Age, fasting glucose, and insulin resistance are main predictors of IGT. We suggest the use of OGTT as a screening tool in obese European adolescents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, L.; Lanza, R.C.
1999-12-01
The authors have developed a near field coded aperture imaging system for use with fast neutron techniques as a tool for the detection of contraband and hidden explosives through nuclear elemental analysis. The technique relies on the prompt gamma rays produced by fast neutron interactions with the object being examined. The position of the nuclear elements is determined by the location of the gamma emitters. For existing fast neutron techniques, in Pulsed Fast Neutron Analysis (PFNA), neutrons are used with very low efficiency; in Fast Neutron Analysis (FNS), the sensitivity for detection of the signature gamma rays is very low.more » For the Coded Aperture Fast Neutron Analysis (CAFNA{reg{underscore}sign}) the authors have developed, the efficiency for both using the probing fast neutrons and detecting the prompt gamma rays is high. For a probed volume of n{sup 3} volume elements (voxels) in a cube of n resolution elements on a side, they can compare the sensitivity with other neutron probing techniques. As compared to PFNA, the improvement for neutron utilization is n{sup 2}, where the total number of voxels in the object being examined is n{sup 3}. Compared to FNA, the improvement for gamma-ray imaging is proportional to the total open area of the coded aperture plane; a typical value is n{sup 2}/2, where n{sup 2} is the number of total detector resolution elements or the number of pixels in an object layer. It should be noted that the actual signal to noise ratio of a system depends also on the nature and distribution of background events and this comparison may reduce somewhat the effective sensitivity of CAFNA. They have performed analysis, Monte Carlo simulations, and preliminary experiments using low and high energy gamma-ray sources. The results show that a high sensitivity 3-D contraband imaging and detection system can be realized by using CAFNA.« less
Langenfeld, Matthias R; Forst, Thomas; Standl, Eberhard; Strotmann, Hermann-Josef; Lübben, Georg; Pahler, Sabine; Kann, Peter; Pfützner, Andreas
2004-12-01
This study was performed to compare the specificity and sensitivity of intact proinsulin, adiponectin, and their ratio (proinsulin/adiponectin) in the prediction of insulin resistance as assessed by the homeostasis model assessment (HOMA) score (> or =2 = resistant). Using a cross-sectional approach, 500 orally treated patients with type 2 diabetes (272 women, 238 men; mean +/- SD age, 64.8 +/- 11.6 years; hemoglobin A1c, 7.0 +/- 1.5%; disease duration, 5.8 +/- 6.1 years) were investigated. Various cutoffs for body mass index-adjusted adiponectin and proinsulin/adiponectin were compared with the established cutoff value of 10 pmol/L for fasting proinsulin. Fasting proinsulin correlated more closely with the HOMA score (r = 0.560, P < 0.001) than fasting adiponectin (r = -0.204, P < 0.001) or proinsulin/adiponectin (r = 0.355, P < 0.001). For proinsulin, specificity and sensitivity for insulin resistance in correlation to the HOMA score results were 96% and 70%, respectively. At a comparable specificity level to proinsulin, adiponectin did not reach a comparable sensitivity (14%), while the proinsulin/adiponectin ratio almost reached the same sensitivity (65%). Overall, patients with elevated proinsulin had a higher prevalence of micro- and macrovascular disease [odds ratio 1.47 (adiponectin, 1.08; proinsulin/ adiponectin, 1.48) and 1.34 (adiponectin, 1.32; proinsulin/adiponectin, 1.27), respectively]. Elevation of fasting intact proinsulin seems to be the more specific marker for insulin resistance and increased cardiovascular risk than suppression of fasting adiponectin. Formation of the ratio does not lead to a further increase in the predictive value.
NASA Astrophysics Data System (ADS)
Ishii, Yoshitaka; Wickramasinghe, Ayesha; Matsuda, Isamu; Endo, Yuki; Ishii, Yuji; Nishiyama, Yusuke; Nemoto, Takahiro; Kamihara, Takayuki
2018-01-01
Proton-detected solid-state NMR (SSNMR) spectroscopy has attracted much attention due to its excellent sensitivity and effectiveness in the analysis of trace amounts of amyloid proteins and other important biological systems. In this perspective article, we present the recent sensitivity limit of 1H-detected SSNMR using "ultra-fast" magic-angle spinning (MAS) at a spinning rate (νR) of 80-100 kHz. It was demonstrated that the high sensitivity of 1H-detected SSNMR at νR of 100 kHz and fast recycling using the paramagnetic-assisted condensed data collection (PACC) approach permitted "super-fast" collection of 1H-detected 2D protein SSNMR. A 1H-detected 2D 1H-15N correlation SSNMR spectrum for ∼27 nmol of a uniformly 13C- and 15N-labeled GB1 protein sample in microcrystalline form was acquired in only 9 s with 50% non-uniform sampling and short recycle delays of 100 ms. Additional data suggests that it is now feasible to detect as little as 1 nmol of the protein in 5.9 h by 1H-detected 2D 1H-15N SSNMR at a nominal signal-to-noise ratio of five. The demonstrated sensitivity is comparable to that of modern solution protein NMR. Moreover, this article summarizes the influence of ultra-fast MAS and 1H-detection on the spectral resolution and sensitivity of protein SSNMR. Recent progress in signal assignment and structural elucidation by 1H-detected protein SSNMR is outlined with both theoretical and experimental aspects.
NASA Astrophysics Data System (ADS)
Zhao, Bingshan; He, Man; Chen, Beibei; Xu, Hongrun; Hu, Bin
2018-05-01
In this study, poly(1-vinylimidazole) functionalized gold ion imprinted polymer coated magnetic nanoparticles (MNPs@PVIM-Au-IIP) were prepared and characterized. The adsorption behaviors of the prepared MNPs@PVIM-Au-IIP toward gold ions (Au(III)) were studied, it was found that MNPs@PVIM-Au-IIP has good selectivity, high adsorption capacity (185.4 mg g-1) and fast adsorption kinetic for Au(III). Based on it, a new method of ion imprinted magnetic solid phase extraction (II-MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) detection was proposed for the analysis of trace Au(III) in real samples with complicated matrix. Factors affecting MSPE including sample pH, desorption reagent, elution concentration and volume, elution time, sample volume and adsorption time were optimized. With high enrichment factor of 100-fold, the detection limit of the proposed method is 7.9 ng L-1 for Au(III) with the relative standard deviation of 7.4% (c = 50 ng L-1, n = 7). In order to validate the accuracy of the proposed method, the Certified Reference Material of GBW07293 geological sample (platinpalladium ore) was analyzed, and the determined value was in good agreement with the certified value. The proposed II-MSPE-GFAAS method is simple, fast, selective, sensitive and has been successfully applied in the determination of trace Au in ore, sediment, environmental water and human urine samples with satisfactory results.
Pedersen, Morten Høgild; Svart, Mads Vandsted; Lebeck, Janne; Bidlingmaier, Martin; Stødkilde-Jørgensen, Hans; Pedersen, Steen Bønløkke; Møller, Niels; Jessen, Niels; Jørgensen, Jens O L
2017-04-01
Insulin resistance and metabolic inflexibility are features of obesity and are amplified by fasting. Growth hormone (GH) secretion increases during fasting and GH causes insulin resistance. To study the metabolic effects of GH blockade during fasting in obese subjects. Nine obese males were studied thrice in a randomized design: (1) after an overnight fast (control), (2) after 72 hour fasting (fasting), and (3) after 72 hour fasting with GH blockade (pegvisomant) [fasting plus GH antagonist (GHA)]. Each study day consisted of a 4-hour basal period followed by a 2-hour hyperinsulinemic, euglycemic clamp combined with indirect calorimetry, assessment of glucose and palmitate turnover, and muscle and fat biopsies. GH levels increased with fasting (P < 0.01), and the fasting-induced reduction of serum insulin-like growth factor I was enhanced by GHA (P < 0.05). Fasting increased lipolysis and lipid oxidation independent of GHA, but fasting plus GHA caused a more pronounced suppression of lipid intermediates in response to hyperinsulinemic, euglycemic clamp. Fasting-induced insulin resistance was abrogated by GHA (P < 0.01) primarily due to reduced endogenous glucose production (P = 0.003). Fasting plus GHA also caused elevated glycerol levels and reduced levels of counterregulatory hormones. Fasting significantly reduced the expression of antilipolytic signals in adipose tissue independent of GHA. Suppression of GH activity during fasting in obese subjects reverses insulin resistance and amplifies insulin-stimulated suppression of lipid intermediates, indicating that GH is an important regulator of substrate metabolism, insulin sensitivity, and metabolic flexibility also in obese subjects. Copyright © 2017 by the Endocrine Society
Noninvasive type 2 diabetes screening: superior sensitivity to fasting plasma glucose and A1C.
Maynard, John D; Rohrscheib, Mark; Way, Jeffrey F; Nguyen, Catriona M; Ediger, Marwood N
2007-05-01
This study compared the performance of a novel noninvasive technology to fasting plasma glucose (FPG) and A1C tests for detecting undiagnosed diabetes and impaired glucose tolerance. The design was a head-to-head evaluation in a naïve population. Consented subjects received FPG and A1C tests and an oral glucose tolerance test (OGTT). Subjects were also measured by a noninvasive device that detects the fluorescence of skin advanced glycation end products. A total of 351 subjects participated. Subjects with 2-h OGTT values > or = 140 mg/dl defined the positive screening class. A total of 84 subjects (23.9% prevalence) screened positive. The performances of the noninvasive device, FPG, and A1C were evaluated for sensitivity and specificity against this classification. At the impaired fasting glucose threshold (FPG = 100 mg/dl), the FPG testing sensitivity was 58% and the specificity was 77.4%. At that same specificity, the sensitivity for A1C testing was 63.8%, while the noninvasive testing sensitivity was 74.7%. The sensitivity advantage of the noninvasive device over both blood tests for detecting diabetes and precursors was statistically significant (P < 0.05). The noninvasive technology showed clinical performance advantages over both FPG and A1C testing. The sensitivity differential indicated that the noninvasive device is capable of identifying 28.8% more individuals in the OGTT-defined positive screening class than FPG testing and 17.1% more than A1C testing. The combination of higher sensitivity and greater convenience--rapid results with no fasting or blood draws--makes the device well suited for opportunistic screening.
Fast Coherent Differential Imaging for Exoplanet Imaging
NASA Astrophysics Data System (ADS)
Gerard, Benjamin; Marois, Christian; Galicher, Raphael; Veran, Jean-Pierre; Macintosh, B.; Guyon, O.; Lozi, J.; Pathak, P.; Sahoo, A.
2018-06-01
Direct detection and detailed characterization of exoplanets using extreme adaptive optics (ExAO) is a key science goal of future extremely large telescopes and space observatories. However, quasi-static wavefront errors will limit the sensitivity of this endeavor. Additional limitations for ground-based telescopes arise from residual AO-corrected atmospheric wavefront errors, generating short-lived aberrations that will average into a halo over a long exposure, also limiting the sensitivity of exoplanet detection. We develop the framework for a solution to both of these problems using the self-coherent camera (SCC), to be applied to ground-based telescopes, called Fast Atmospheric SCC Technique (FAST). Simulations show that for typical ExAO targets the FAST approach can reach ~100 times better in raw contrast than what is currently achieved with ExAO instruments if we extrapolate for an hour of observing time, illustrating that the sensitivity improvement from this method could play an essential role in the future ground-based detection and characterization of lower mass/colder exoplanets.
Saravanan, Adhimoorthy; Huang, Bohr-Ran; Kathiravan, Deepa; Prasannan, Adhimoorthy
2017-11-15
Granular activated carbon (GAC) materials were prepared via simple gas activation of silkworm cocoons and were coated on ZnO nanorods (ZNRs) by the facile hydrothermal method. The present combination of GAC and ZNRs shows a core-shell structure (where the GAC is coated on the surface of ZNRs) and is exposed by systematic material analysis. The as-prepared samples were then fabricated as dual-functional sensors and, most fascinatingly, the as-fabricated core-shell structure exhibits better UV and H 2 sensing properties than those of as-fabricated ZNRs and GAC. Thus, the present core-shell structure-based H 2 sensor exhibits fast responses of 11% (10 ppm) and 23.2% (200 ppm) with ultrafast response and recovery. However, the UV sensor offers an ultrahigh photoresponsivity of 57.9 A W -1 , which is superior to that of as-grown ZNRs (0.6 A W -1 ). Besides this, switching photoresponse of GAC/ZNR core-shell structures exhibits a higher switching ratio (between dark and photocurrent) of 1585, with ultrafast response and recovery, than that of as-grown ZNRs (40). Because of the fast adsorption ability of GAC, it was observed that the finest distribution of GAC on ZNRs results in rapid electron transportation between the conduction bands of GAC and ZNRs while sensing H 2 and UV. Furthermore, the present core-shell structure-based UV and H 2 sensors also well-retained excellent sensitivity, repeatability, and long-term stability. Thus, the salient feature of this combination is that it provides a dual-functional sensor with biowaste cocoon and ZnO, which is ecological and inexpensive.
Li, Zhao; Liu, Yong; Wei, Qingquan; Liu, Yuanjie; Liu, Wenwen; Zhang, Xuelian; Yu, Yude
2016-01-01
Absolute, precise quantification methods expand the scope of nucleic acids research and have many practical applications. Digital polymerase chain reaction (dPCR) is a powerful method for nucleic acid detection and absolute quantification. However, it requires thermal cycling and accurate temperature control, which are difficult in resource-limited conditions. Accordingly, isothermal methods, such as recombinase polymerase amplification (RPA), are more attractive. We developed a picoliter well array (PWA) chip with 27,000 consistently sized picoliter reactions (314 pL) for isothermal DNA quantification using digital RPA (dRPA) at 39°C. Sample loading using a scraping liquid blade was simple, fast, and required small reagent volumes (i.e., <20 μL). Passivating the chip surface using a methoxy-PEG-silane agent effectively eliminated cross-contamination during dRPA. Our creative optical design enabled wide-field fluorescence imaging in situ and both end-point and real-time analyses of picoliter wells in a 6-cm(2) area. It was not necessary to use scan shooting and stitch serial small images together. Using this method, we quantified serial dilutions of a Listeria monocytogenes gDNA stock solution from 9 × 10(-1) to 4 × 10(-3) copies per well with an average error of less than 11% (N = 15). Overall dRPA-on-chip processing required less than 30 min, which was a 4-fold decrease compared to dPCR, requiring approximately 2 h. dRPA on the PWA chip provides a simple and highly sensitive method to quantify nucleic acids without thermal cycling or precise micropump/microvalve control. It has applications in fast field analysis and critical clinical diagnostics under resource-limited settings.
Li, Zhao; Liu, Yong; Wei, Qingquan; Liu, Yuanjie; Liu, Wenwen; Zhang, Xuelian; Yu, Yude
2016-01-01
Absolute, precise quantification methods expand the scope of nucleic acids research and have many practical applications. Digital polymerase chain reaction (dPCR) is a powerful method for nucleic acid detection and absolute quantification. However, it requires thermal cycling and accurate temperature control, which are difficult in resource-limited conditions. Accordingly, isothermal methods, such as recombinase polymerase amplification (RPA), are more attractive. We developed a picoliter well array (PWA) chip with 27,000 consistently sized picoliter reactions (314 pL) for isothermal DNA quantification using digital RPA (dRPA) at 39°C. Sample loading using a scraping liquid blade was simple, fast, and required small reagent volumes (i.e., <20 μL). Passivating the chip surface using a methoxy-PEG-silane agent effectively eliminated cross-contamination during dRPA. Our creative optical design enabled wide-field fluorescence imaging in situ and both end-point and real-time analyses of picoliter wells in a 6-cm2 area. It was not necessary to use scan shooting and stitch serial small images together. Using this method, we quantified serial dilutions of a Listeria monocytogenes gDNA stock solution from 9 × 10-1 to 4 × 10-3 copies per well with an average error of less than 11% (N = 15). Overall dRPA-on-chip processing required less than 30 min, which was a 4-fold decrease compared to dPCR, requiring approximately 2 h. dRPA on the PWA chip provides a simple and highly sensitive method to quantify nucleic acids without thermal cycling or precise micropump/microvalve control. It has applications in fast field analysis and critical clinical diagnostics under resource-limited settings. PMID:27074005
A pipette-based calibration system for fast-scan cyclic voltammetry with fast response times.
Ramsson, Eric S
2016-01-01
Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique that utilizes the oxidation and/or reduction of an analyte of interest to infer rapid changes in concentrations. In order to calibrate the resulting oxidative or reductive current, known concentrations of an analyte must be introduced under controlled settings. Here, I describe a simple and cost-effective method, using a Petri dish and pipettes, for the calibration of carbon fiber microelectrodes (CFMs) using FSCV.
Gog, Simon; Bader, Martin
2008-10-01
The problem of sorting signed permutations by reversals is a well-studied problem in computational biology. The first polynomial time algorithm was presented by Hannenhalli and Pevzner in 1995. The algorithm was improved several times, and nowadays the most efficient algorithm has a subquadratic running time. Simple permutations played an important role in the development of these algorithms. Although the latest result of Tannier et al. does not require simple permutations, the preliminary version of their algorithm as well as the first polynomial time algorithm of Hannenhalli and Pevzner use the structure of simple permutations. More precisely, the latter algorithms require a precomputation that transforms a permutation into an equivalent simple permutation. To the best of our knowledge, all published algorithms for this transformation have at least a quadratic running time. For further investigations on genome rearrangement problems, the existence of a fast algorithm for the transformation could be crucial. Another important task is the back transformation, i.e. if we have a sorting on the simple permutation, transform it into a sorting on the original permutation. Again, the naive approach results in an algorithm with quadratic running time. In this paper, we present a linear time algorithm for transforming a permutation into an equivalent simple permutation, and an O(n log n) algorithm for the back transformation of the sorting sequence.
Fateh, Abolfazl; Aghasadeghi, Mohammad Reza; Keyvani, Hossein; Mollaie, Hamid Reza; Yari, Shamsi; Hadizade Tasbiti, Ali Reza; Ghazanfari, Morteza; Monavari, Seyed Hamid Reza
2015-01-01
A recent genome-wide association study (GWAS) on patients with chronic hepatitis C (CHC) treated with peginterferon and ribavirin (pegIFN-α/RBV) identified a single nucleotide polymorphism (SNP) on chromosome 19 (rs12979860) which was strongly associated with a sustained virological response (SVR). The aim of this study was twofold: to study the relationship between IL28B rs12979860 and sustained virological response (SVR) to pegIFN-α/RVB therapy among CHC patients and to detect the rs12979860 polymorphism by high resolution melting curve (HRM) assay as a simple, fast, sensitive, and inexpensive method. The study examined outcomes in 100 patients with chronic hepatitis C in 2 provinces of Iran from December 2011 to June 2013. Two methods were applied to detect IL28B polymorphisms: PCR-sequencing as a gold standard method and HRM as a simple, fast, sensitive, and inexpensive method. The frequencies of IL28B rs12979860 CC, CT, and TT alleles in chronic hepatitis C genotype 1a patients were 10% (10/100), 35% (35/100), and 6% (6/100) and in genotype 3a were 13% (13/100), 31% (31/100), and 5% (5/100), respectively. In genotype 3a infected patients, rs12979860 (CC and CT alleles) and in genotype 1a infected patients (CC allele) were significantly associated with a sustained virological response (SVR). The SVR rates for CC, CT and TT (IL28B rs12979860) were 18%, 34% and 4%, respectively. Multiple logistic regression analysis identified two independent factors that were significantly associated with SVR: IL-28B genotype (rs 12979860 CC vs TT and CT; odds ratio [ORs], 7.86 and 4.084, respectively), and HCV subtype 1a (OR, 7.46). In the present study, an association between SVR rates and IL28B polymorphisms was observed. The HRM assay described herein is rapid, inexpensive, sensitive and accurate for detecting rs12979860 alleles in CHC patients. This method can be readily adopted by any molecular diagnostic laboratory with HRM capability and will be clinically beneficial in predicting treatment response in HCV genotype 1 and 3 infected patients. In addition, it was demonstrated that CC and CT alleles in HCV-3a and the CC allele in HCV-1a were significantly associated with response to pegIFN-α/RBV treatment. The present results may help identify subjects for whom the therapy might be successful.
Mi, Mantian; Wang, Jian
2014-01-01
Background Diabetes mellitus has become a worldwide health problem. Whether fruit juice is beneficial in glycemic control is still inconclusive. This study aimed to synthesize evidence from randomized controlled trials on fruit juice in relationship to glucose control and insulin sensitivity. Methods A strategic literature search of PubMed, EMBASE, and the Cochrane Library (updated to March, 2014) was performed to retrieve the randomized controlled trials that evaluated the effects of fruit juice on glucose control and insulin sensitivity. Study quality was assessed using the Jadad scale. Weighted mean differences were calculated for net changes in the levels of fasting glucose, fasting insulin, hemoglobin A1c (HbA1c), and homeostatic model assessment of insulin resistance (HOMA-IR) using fixed- or random-effects model. Prespecified subgroup and sensitivity analyses were performed to explore the potential heterogeneity. Results Twelve trials comprising a total of 412 subjects were included in the current meta-analysis. The numbers of these studies that reported the data on fasting glucose, fasting insulin, HbA1c and HOMA-IR were 12, 5, 3 and 3, respectively. Fruit juice consumption did not show a significant effect on fasting glucose and insulin concentrations. The net change was 0.79 mg/dL (95% CI: −1.44, 3.02 mg/dL; P = 0.49) for fasting glucose concentrations and −0.74 µIU/ml (95% CI: −2.62, 1.14 µIU/ml; P = 0.44) for fasting insulin concentrations in the fixed-effects model. Subgroup analyses further suggested that the effect of fruit juice on fasting glucose concentrations was not influenced by population region, baseline glucose concentration, duration, type of fruit juice, glycemic index of fruit juice, fruit juice nutrient constitution, total polyphenols dose and Jadad score. Conclusion This meta-analysis showed that fruit juice may have no overall effect on fasting glucose and insulin concentrations. More RCTs are warranted to further clarify the association between fruit juice and glycemic control. PMID:24743260
Cheng, Arthur J.; Hartman, James J.; Hinken, Aaron C.; Lee, Ken; Durham, Nickie; Russell, Alan J.; Malik, Fady I.; Westerblad, Håkan; Jasper, Jeffrey R.
2017-01-01
Key points We report that the small molecule CK‐2066260 selectively slows the off‐rate of Ca2 + from fast skeletal muscle troponin, leading to increased myofibrillar Ca2 + sensitivity in fast skeletal muscle.Rodents dosed with CK‐2066260 show increased hindlimb muscle force and power in response to submaximal rates of nerve stimulation in situ.CK‐2066260 has no effect on free cytosolic [Ca2 +] during contractions of isolated muscle fibres.We conclude that fast skeletal muscle troponin sensitizers constitute a potential therapy to address an unmet need of improving muscle function in conditions of weakness and premature muscle fatigue. Abstract Skeletal muscle dysfunction occurs in many diseases and can lead to muscle weakness and premature muscle fatigue. Here we show that the fast skeletal troponin activator, CK‐2066260, counteracts muscle weakness by increasing troponin Ca2+ affinity, thereby increasing myofibrillar Ca2+ sensitivity. Exposure to CK‐2066260 resulted in a concentration‐dependent increase in the Ca2+ sensitivity of ATPase activity in isolated myofibrils and reconstituted hybrid sarcomeres containing fast skeletal muscle troponin C. Stopped‐flow experiments revealed a ∼2.7‐fold decrease in the Ca2+ off‐rate of isolated troponin complexes in the presence of CK‐2066260 (6 vs. 17 s−1 under control conditions). Isolated mouse flexor digitorum brevis fibres showed a rapidly developing, reversible and concentration‐dependent force increase at submaximal stimulation frequencies. This force increase was not accompanied by any changes in the free cytosolic [Ca2+] or its kinetics. CK‐2066260 induced a slowing of relaxation, which was markedly larger at 26°C than at 31°C and could be linked to the decreased Ca2+ off‐rate of troponin C. Rats dosed with CK‐2066260 showed increased hindlimb isometric and isokinetic force in response to submaximal rates of nerve stimulation in situ producing significantly higher absolute forces at low isokinetic velocities, whereas there was no difference in force at the highest velocities. Overall muscle power was increased and the findings are consistent with a lack of effect on crossbridge kinetics. In conclusion, CK‐2066260 acts as a fast skeletal troponin activator that may be used to increase muscle force and power in conditions of muscle weakness. PMID:27869319
Ozgu-Erdinc, A Seval; Yilmaz, Saynur; Yeral, M Ilkin; Seckin, K Doga; Erkaya, Salim; Danisman, A Nuri
2015-11-01
To develop a predictive index based on high sensitivity C-reactive protein (hs-CRP), fasting plasma glucose (FPG) and fasting plasma insulin (FPI) measurements for early diagnosis of gestational diabetes mellitus (GDM). Healthy pregnant women who were screened for GDM during their first antenatal visit were included in this retrospective cohort study. FPG, FPI and serum hs-CRP concentrations were measured between weeks 11 and 14. A two-step glucose challenge test was carried out between gestational weeks 24 and 28. Fasting glucose/insulin ratio (FIGR), Homeostatic Model Assessment Insulin Resistance (HOMA-IR), HOMA-β indices and Quantitative Insulin Sensitivity Check Index (QUICKI) were used to estimate insulin sensitivity and β-cell function. Of the 450 women who were eligible for the study, 49 (11.2%) were diagnosed with GDM at weeks 24-28. The median FPG and hs-CRP levels were higher in the GDM diagnosed women compared to the others. Comparison of accuracy measures resulted in the highest specificity (87.2%; 95% CI 83.5-90.1) and diagnostic odds ratio (3.9; 95% CI 2.1-7.6) for hs-CRP. FPG and hs-CRP in the first trimester are correlated with later development of GDM in the pregnancy. In our study, FPG provided a better sensitivity while hs-CRP exhibited a better specificity for prediction of GDM.
Comparative evaluation of simple indices of insulin resistance.
Vaccaro, Olga; Masulli, Maria; Cuomo, Vincenzo; Rivellese, Angela Albarosa; Uusitupa, Matti; Vessby, Bengt; Hermansen, Kjeld; Tapsell, Linda; Riccardi, Gabriele
2004-12-01
Various surrogate methods for the quantification of insulin sensitivity have been proposed. A comparative evaluation is lacking and is relevant for the standardization of investigative methods and comparability of results. The aims of the study were to perform a comparative validation of fasting insulin, homeostasis model assessment (HOMA), Quantitative Insulin Sensitivity Check Index (QUICKI), and revised-QUICKI (R-QUICKI) against minimal model derived estimates of insulin sensitivity (SI(MM)) in nondiabetic people and to carry out a comparative evaluation of the ability of these indices as means for the identification of individuals with the metabolic syndrome (MS) on a population basis. We used 2 data sets defined as "validation sample" and "prevalence sample". Validation sample: a total of 162 healthy men and women aged 30 to 65 years were studied by frequently sampled intravenous glucose tolerance test (FSIVGTT). SI(MM) was calculated with the Minmod program. Prevalence sample: a total of 2,731 nondiabetic men and women aged 35 to 65 years were studied. In both samples, anthropometry, blood pressure, fasting glucose, insulin, triglycerides, high-density lipoprotein (HDL) cholesterol, and free fatty acid (FFA) were measured. HOMA, QUICKI, and R-QUICKI were calculated. The MS was defined according to the Adult Treatment Panel III. Validation sample: insulin, HOMA, QUICKI, and R-QUICKI significantly correlated with SI(MM) (r = -0,53, -0.52, 0.41, 0.33; all P < .001). The finding was confirmed in obese (body mass index [BMI] > or =25 kg/m(2)), but in the normal weight, the correlation coefficient for QUICKI was significantly smaller than for the other indices. Receiver operator characteristic (ROC) curve analysis performed with SI(MM) below or above the lowest 25th percentile (ie, insulin resistance yes, no) as the outcome variable and each of the 4 indices as the test variable showed no significant differences in the areas under the curve. Prevalence sample: prevalence of the MS progressively increased across quartiles of insulin resistance as evaluated by any of the 4 indices, with no significant differences between them. The novel indices QUICKI and R-QUICKI do not perform better than HOMA and fasting insulin as surrogate measures of insulin resistance or means for the identification of people with MS in the general population.
NASA Astrophysics Data System (ADS)
Zhai, Chen; Li, Yongyu; Peng, Yankun; Xu, Tianfeng; Dhakal, Sagar; Chao, Kuanglin; Qin, Jianwei
2015-05-01
Residual pesticides in fruits and vegetables have become one of the major food safety concerns around the world. At present, routine analytical methods used for the determination of pesticide residue on the surface of fruits and vegetables are destructive, complex, time-consuming, high cost and not environmentally friendly. In this study, a novel Surface Enhanced Raman Spectroscopy (SERS) method with silver colloid was developed for fast and sensitive nondestructive detection of residual pesticides in fruits and vegetables by using a self-developed Raman system. SERS technology is a combination of Raman spectroscopy and nanotechnology. SERS can greatly enhance the Raman signal intensity, achieve single-molecule detection, and has a simple sample pre-treatment characteristic of high sensitivity and no damage; in recent years it has begun to be used in food safety testing research. In this study a rapid and sensitive method was developed to identify and analyze mixed pesticides of chlorpyrifos, deltamethrin and acetamiprid in apple samples by SERS. Silver colloid was used for SERS measurement by hydroxylamine hydrochloride reduced. The advantages of this method are seen in its fast preparation at room temperature, good reproducibility and immediate applicability. Raman spectrum is highly interfered by noise signals and fluorescence background, which make it too complex to get good result. In this study the noise signals and fluorescence background were removed by Savitzky-Golay filter and min-max signal adaptive zooming method. Under optimal conditions, pesticide residues in apple samples can be detected by SERS at 0.005 μg/cm2 and 0.002 μg/cm2 for individual acetamiprid and thiram, respectively. When mixing the two pesticides at low concentrations, their characteristic peaks can still be identified from the SERS spectrum of the mixture. Based on the synthesized material and its application in SERS operation, the method represents an ultrasensitive SERS performance in apple samples detection without sample pre-treatment, which indicates that it could be served as a useful means in monitoring pesticide residues.
Simple and fast screening of G-quadruplex ligands with electrochemical detection system.
Fan, Qiongxuan; Li, Chao; Tao, Yaqin; Mao, Xiaoxia; Li, Genxi
2016-11-01
Small molecules that may facilitate and stabilize the formation of G-quadruplexes can be used for cancer treatments, because the G-quadruplex structure can inhibit the activity of telomerase, an enzyme over-expressed in many cancer cells. Therefore, there is considerable interest in developing a simple and high-performance method for screening small molecules binding to G-quadruplex. Here, we have designed a simple electrochemical approach to screen such ligands based on the fact that the formation and stabilization of G-quadruplex by ligand may inhibit electron transfer of redox species to electrode surface. As a proof-of-concept study, two types of classical G-quadruplex ligands, TMPyP4 and BRACO-19, are studied in this work, which demonstrates that this method is fast and robust and it may be applied to screen G-quadruplex ligands for anticancer drugs testing and design in the future. Copyright © 2016 Elsevier B.V. All rights reserved.
Insulin sensitivity and cardiac autonomic function in young male practitioners of yoga.
Chaya, M S; Ramakrishnan, G; Shastry, S; Kishore, R P; Nagendra, H; Nagarathna, R; Raj, T; Thomas, T; Vaz, M; Kurpad, A V
2008-01-01
While yoga is thought to reduce the risk of chronic non-communicable diseases such as diabetes, there are no studies on insulin sensitivity in long term practitioners of yoga. We assessed insulin sensitivity and cardiac autonomic function in long term practitioners of yoga. Fifteen healthy, young, male practitioners of yoga were compared with 15 young, healthy males who did not practice yoga matched for body-mass index. Fasting insulin sensitivity was measured in the fasting state by the hyperinsulinaemic-euglycaemic clamp. There were no significant differences between the groups in their anthropometry or body composition. However, the fasting plasma insulin was significantly lower in the yoga group. The yoga group was also more insulin sensitive (yoga 7.82 [2.29] v. control 4.86 [11.97] (mg/[kg.min])/(microU/ml), p < 0.001). While the body weight and waist circumference were negatively correlated with glucose disposal rate in the controls, there were no similar correlations in the yoga group. The yoga group had significantly higher low-frequency power and lower normalized high-frequency power. Long term yoga practice (for 1 year or more) is associated with increased insulin sensitivity and attenuates the negative relationship between body weight or waist circumference and insulin sensitivity.
Sensitivity Analysis of Wing Aeroelastic Responses
NASA Technical Reports Server (NTRS)
Issac, Jason Cherian
1995-01-01
Design for prevention of aeroelastic instability (that is, the critical speeds leading to aeroelastic instability lie outside the operating range) is an integral part of the wing design process. Availability of the sensitivity derivatives of the various critical speeds with respect to shape parameters of the wing could be very useful to a designer in the initial design phase, when several design changes are made and the shape of the final configuration is not yet frozen. These derivatives are also indispensable for a gradient-based optimization with aeroelastic constraints. In this study, flutter characteristic of a typical section in subsonic compressible flow is examined using a state-space unsteady aerodynamic representation. The sensitivity of the flutter speed of the typical section with respect to its mass and stiffness parameters, namely, mass ratio, static unbalance, radius of gyration, bending frequency, and torsional frequency is calculated analytically. A strip theory formulation is newly developed to represent the unsteady aerodynamic forces on a wing. This is coupled with an equivalent plate structural model and solved as an eigenvalue problem to determine the critical speed of the wing. Flutter analysis of the wing is also carried out using a lifting-surface subsonic kernel function aerodynamic theory (FAST) and an equivalent plate structural model. Finite element modeling of the wing is done using NASTRAN so that wing structures made of spars and ribs and top and bottom wing skins could be analyzed. The free vibration modes of the wing obtained from NASTRAN are input into FAST to compute the flutter speed. An equivalent plate model which incorporates first-order shear deformation theory is then examined so it can be used to model thick wings, where shear deformations are important. The sensitivity of natural frequencies to changes in shape parameters is obtained using ADIFOR. A simple optimization effort is made towards obtaining a minimum weight design of the wing, subject to flutter constraints, lift requirement constraints for level flight and side constraints on the planform parameters of the wing using the IMSL subroutine NCONG, which uses successive quadratic programming.
FastID: Extremely Fast Forensic DNA Comparisons
2017-05-19
FastID: Extremely Fast Forensic DNA Comparisons Darrell O. Ricke, PhD Bioengineering Systems & Technologies Massachusetts Institute of...Technology Lincoln Laboratory Lexington, MA USA Darrell.Ricke@ll.mit.edu Abstract—Rapid analysis of DNA forensic samples can have a critical impact on...time sensitive investigations. Analysis of forensic DNA samples by massively parallel sequencing is creating the next gold standard for DNA
NASA Astrophysics Data System (ADS)
Bolte, Nathan; Heidbrink, W. W.; Pace, D. C.; van Zeeland, M. A.; Chen, X.
2015-11-01
A new fast-ion diagnostic method uses passive emission of D-alpha radiation to determine fast-ion losses quantitatively. The passive fast-ion D-alpha simulation (P-FIDAsim) forward models the Doppler-shifted spectra of first-orbit fast ions that charge exchange with edge neutrals. Simulated spectra are up to 80 % correlated with experimental spectra. Calibrated spectra are used to estimate the 2D neutral density profile by inverting simulated spectra. The inferred neutral density shows the expected increase toward each x-point and an average value of 8 × 10 9 cm-3 at the plasma boundary and 1 × 10 11 cm-3 near the wall. Measuring and simulating first-orbit spectra effectively ``calibrates'' the system, allowing for the quantification of more general fast-ion losses. Sawtooth crashes are estimated to eject 1.2 % of the fast-ion inventory, in good agreement with a 1.7 % loss estimate made by TRANSP. Sightlines sensitive to passing ions observe larger sawtooth losses than sightlines sensitive to trapped ions. Supported by US DOE under SC-G903402, DE-FC02-04ER54698.
Mushi, Martha Fidelis; Paterno, Laurent; Tappe, Dennis; Deogratius, Anna Pendo; Seni, Jeremiah; Moremi, Nyambura; Mirambo, Mariam Mwijuma; Mshana, Stephen Eliatosha
2014-01-01
Introduction Campylobacter species are recognized as a major cause of acute gastroenteritis in humans throughout the world. The diagnosis is mainly based on stool culture. This study was done to evaluate the effectiveness of staining methods (Gram stain using 0.3% carbol fuchsin as counter stain and 1% carbol fuchsin direct stain) versus culture as the gold standard. Methods A total of 300 children attending Bugando Medical Centre (BMC) and the Sekou Toure regional hospital with acute watery diarrhea were enrolled. Two sets of slides were prepared stained with 1% carbol fuchsin for 30 seconds first set, and the second set stained with Gram's stain using 0.3% carbol fuchsin as counter stain for five minutes. Concurrently, stool samples were inoculated on Preston Agar selective. Results Of 300 stool specimens, 14(4.7%) showed positive culture after 48 hours of incubation and 28 (9.3%) shows typical morphology of Campylobacter species by both Gram stain and direct stain. The sensitivity of the Gram stain using 0.3% carbol fuchsin as counter stain and 1% carbol fuchsin simple stain versus culture as gold standard was 64.3%, with a specificity of 93.4%. The positive predictive value and negative predictive value were 32.1% and 98.2% respectively. Conclusion The detection of Campylobacter by 1% carbol fuchsin is simple, inexpensive, and fast, with both a high sensitivity and specificity. Laboratories in settings with high prevalence of campylobacteriosis and/or limited resources can employ 1% carbol fuchsin direct stain in detecting campylobacter infections. PMID:25995788
Chantada-Vázquez, María Pilar; Sánchez-González, Juan; Peña-Vázquez, Elena; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2016-03-01
A new molecularly imprinted polymer (MIP)-based fluorescent artificial receptor has been prepared by anchoring a selective MIP for cocaine (COC) on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). The prepared material combines the high selectivity attributed to MIPs and the sensitive fluorescent property of the Mn-doped ZnS QDs. Simple and low cost methods have therefore been optimized for assessing cocaine abuse in urine by monitoring the fluorescence quenching when the template (COC) and also metabolites from COC [benzoylecgonine (BZE) and ecgonine methyl ester (EME)] are present. Fluorescence quenching was not observed when performing experiments with other drugs of abuse (and their metabolites) or when using nonimprinted polymer (NIP)-coated QDs. Under optimized operating conditions (1.5 mL of 200 mg L(-1) MIP-coated QDs solution, pH 5.5, and 15 min before fluorescence scanning) two analytical methods were developed/validated. One of the procedures (direct method) consisted of urine sample 1:20 dilution before fluorescence measurements. The method has been found to be fast, precise, and accurate, but the standard addition technique for performing the analysis was required because of the existence of matrix effect. The second procedure performed a solid phase extraction (SPE) first, avoiding matrix effect and allowing external calibration. The limits of detection of the methods were 0.076 mg L(-1) (direct method) and 0.0042 mg L(-1) (SPE based method), which are lower than the cutoff values for confirmative conclusions regarding cocaine abuse.
Arulraj, Abraham Daniel; Vijayan, Muthunanthevar; Vasantha, Vairathevar Sivasamy
2015-10-29
An ultrasensitive and highly selective electrochemical sensor for the determination of p-nitrophenol (p-NP) was developed based on electrochemically treated nano polypyrrole/sodium dodecyl sulphate film (ENPPy/SDS film) modified glassy carbon electrode. The nano polypyrrole/sodium dodecyl sulphate film (NPPy/SDS film) was prepared and treated electrochemically in phosphate buffer solution. The surface morphology and elemental analysis of treated and untreated NPPy/SDS film were characterized by FESEM and EDX analysis, respectively. Wettability of polymer films were analysed by contact angle test. The hydrophilic nature of the polymer film decreased after electrochemical treatment. Effect of the pH of electrolyte and thickness of the ENPPy/SDS film on determination of p-NP was optimised by cyclic voltammetry. Under the optimised conditions, the p-NP was determined from the oxidation peak of p-hydroxyaminophenol which was formed from the reduction of p-NP in the reduction segment of cyclic voltammetry. A very good linear detection range (from 0.1 nM to 100 μM) and the best LOD (0.1 nM) were obtained for p-NP with very good selectivity. This detection limit is below to the allowed limit in drinking water, 0.43 μM, proposed by the U.S. Environmental Protection Agency (EPA) and earlier reports. Moreover, ENPPy/SDS film based sensor exhibits high sensitivity (4.4546 μA μM(-1)) to p-NP. Experimental results show that it is a fast and simple sensor for p-NP. Copyright © 2015 Elsevier B.V. All rights reserved.
Paulmichl, Katharina; Hatunic, Mensud; Højlund, Kurt; Jotic, Aleksandra; Krebs, Michael; Mitrakou, Asimina; Porcellati, Francesca; Tura, Andrea; Bergsten, Peter; Forslund, Anders; Manell, Hannes; Widhalm, Kurt; Weghuber, Daniel; Anderwald, Christian-Heinz
2016-09-01
The triglyceride-to-HDL cholesterol (TG/HDL-C) ratio was introduced as a tool to estimate insulin resistance, because circulating lipid measurements are available in routine settings. Insulin, C-peptide, and free fatty acids are components of other insulin-sensitivity indices but their measurement is expensive. Easier and more affordable tools are of interest for both pediatric and adult patients. Study participants from the Relationship Between Insulin Sensitivity and Cardiovascular Disease [43.9 (8.3) years, n = 1260] as well as the Beta-Cell Function in Juvenile Diabetes and Obesity study cohorts [15 (1.9) years, n = 29] underwent oral-glucose-tolerance tests and euglycemic clamp tests for estimation of whole-body insulin sensitivity and calculation of insulin sensitivity indices. To refine the TG/HDL ratio, mathematical modeling was applied including body mass index (BMI), fasting TG, and HDL cholesterol and compared to the clamp-derived M-value as an estimate of insulin sensitivity. Each modeling result was scored by identifying insulin resistance and correlation coefficient. The Single Point Insulin Sensitivity Estimator (SPISE) was compared to traditional insulin sensitivity indices using area under the ROC curve (aROC) analysis and χ(2) test. The novel formula for SPISE was computed as follows: SPISE = 600 × HDL-C(0.185)/(TG(0.2) × BMI(1.338)), with fasting HDL-C (mg/dL), fasting TG concentrations (mg/dL), and BMI (kg/m(2)). A cutoff value of 6.61 corresponds to an M-value smaller than 4.7 mg · kg(-1) · min(-1) (aROC, M:0.797). SPISE showed a significantly better aROC than the TG/HDL-C ratio. SPISE aROC was comparable to the Matsuda ISI (insulin sensitivity index) and equal to the QUICKI (quantitative insulin sensitivity check index) and HOMA-IR (homeostasis model assessment-insulin resistance) when calculated with M-values. The SPISE seems well suited to surrogate whole-body insulin sensitivity from inexpensive fasting single-point blood draw and BMI in white adolescents and adults. © 2016 American Association for Clinical Chemistry.
A New Approximate Chimera Donor Cell Search Algorithm
NASA Technical Reports Server (NTRS)
Holst, Terry L.; Nixon, David (Technical Monitor)
1998-01-01
The objectives of this study were to develop chimera-based full potential methodology which is compatible with overflow (Euler/Navier-Stokes) chimera flow solver and to develop a fast donor cell search algorithm that is compatible with the chimera full potential approach. Results of this work included presenting a new donor cell search algorithm suitable for use with a chimera-based full potential solver. This algorithm was found to be extremely fast and simple producing donor cells as fast as 60,000 per second.
Tanguay, J; Hou, X; Esquinas, P; Vuckovic, M; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A
2015-11-07
Cyclotron production of 99mTc through the (100)Mo(p,2n)99mTc reaction channel is actively being investigated as an alternative to reactor-based (99)Mo generation by nuclear fission of (235)U. Like most radioisotope production methods, cyclotron production of 99mTc will result in creation of unwanted impurities, including Tc and non-Tc isotopes. It is important to measure the amounts of these impurities for release of cyclotron-produced 99mTc (CPTc) for clinical use. Detection of radioactive impurities will rely on measurements of their gamma (γ) emissions. Gamma spectroscopy is not suitable for this purpose because the overwhelming presence of 99mTc and the count-rate limitations of γ spectroscopy systems preclude fast and accurate measurement of small amounts of impurities. In this article we describe a simple and fast method for measuring γ emission rates from radioactive impurities in CPTc. The proposed method is similar to that used to identify (99)Mo breakthrough in generator-produced 99mTc: one dose calibrator (DC) reading of a CPTc source placed in a lead shield is followed by a second reading of the same source in air. Our experimental and theoretical analysis show that the ratio of DC readings in lead to those in air are linearly related to γ emission rates from impurities per MBq of 99mTc over a large range of clinically-relevant production conditions. We show that estimates of the γ emission rates from Tc impurities per MBq of 99mTc can be used to estimate increases in radiation dose (relative to pure 99mTc) to patients injected with CPTc-based radiopharmaceuticals. This enables establishing dosimetry-based clinical-release criteria that can be tested using commercially-available dose calibrators. We show that our approach is highly sensitive to the presence of 93gTc, 93mTc, 94gTc, 94mTc, 95mTc, 95gTc, and 96gTc, in addition to a number of non-Tc impurities.
NASA Astrophysics Data System (ADS)
Tanguay, J.; Hou, X.; Esquinas, P.; Vuckovic, M.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.
2015-11-01
Cyclotron production of {{}99\\text{m}} Tc through the 100Mo(p,2n){{}99\\text{m}} Tc reaction channel is actively being investigated as an alternative to reactor-based 99Mo generation by nuclear fission of 235U. Like most radioisotope production methods, cyclotron production of {{}99\\text{m}} Tc will result in creation of unwanted impurities, including Tc and non-Tc isotopes. It is important to measure the amounts of these impurities for release of cyclotron-produced {{}99\\text{m}} Tc (CPTc) for clinical use. Detection of radioactive impurities will rely on measurements of their gamma (γ) emissions. Gamma spectroscopy is not suitable for this purpose because the overwhelming presence of {{}99\\text{m}} Tc and the count-rate limitations of γ spectroscopy systems preclude fast and accurate measurement of small amounts of impurities. In this article we describe a simple and fast method for measuring γ emission rates from radioactive impurities in CPTc. The proposed method is similar to that used to identify 99Mo breakthrough in generator-produced {{}99\\text{m}} Tc: one dose calibrator (DC) reading of a CPTc source placed in a lead shield is followed by a second reading of the same source in air. Our experimental and theoretical analysis show that the ratio of DC readings in lead to those in air are linearly related to γ emission rates from impurities per MBq of {{}99\\text{m}} Tc over a large range of clinically-relevant production conditions. We show that estimates of the γ emission rates from Tc impurities per MBq of {{}99\\text{m}} Tc can be used to estimate increases in radiation dose (relative to pure {{}99\\text{m}} Tc) to patients injected with CPTc-based radiopharmaceuticals. This enables establishing dosimetry-based clinical-release criteria that can be tested using commercially-available dose calibrators. We show that our approach is highly sensitive to the presence of {{}93\\text{g}} Tc, {{}93\\text{m}} Tc, {{}94\\text{g}} Tc, {{}94\\text{m}} Tc, {{}95\\text{m}} Tc, {{}95\\text{g}} Tc, and {{}96\\text{g}} Tc, in addition to a number of non-Tc impurities.
Not So Fast! (and Not So Frugal!): Rethinking the Recognition Heuristic
ERIC Educational Resources Information Center
Oppenheimer, Daniel M.
2003-01-01
The "fast and frugal" approach to reasoning (Gigerenzer, G., & Todd, P. M. (1999). "Simple heuristics that make us smart." New York: Oxford University Press) claims that individuals use non-compensatory strategies in judgment--the idea that only one cue is taken into account in reasoning. The simplest and most important of these heuristics…
Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School
ERIC Educational Resources Information Center
Bogacz, Bogdan F.; Pedziwiatr, Antoni T.
2014-01-01
A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…
Fast or Frugal, but Not Both: Decision Heuristics under Time Pressure
ERIC Educational Resources Information Center
Bobadilla-Suarez, Sebastian; Love, Bradley C.
2018-01-01
Heuristics are simple, yet effective, strategies that people use to make decisions. Because heuristics do not require all available information, they are thought to be easy to implement and to not tax limited cognitive resources, which has led heuristics to be characterized as fast-and-frugal. We question this monolithic conception of heuristics…
De Decker, Annelies; Verbeken, Sandra; Sioen, Isabelle; Van Lippevelde, Wendy; Braet, Caroline; Eiben, Gabriele; Pala, Valeria; Reisch, Lucia A; De Henauw, Stefaan
2017-04-01
To understand the importance of the home food environment on unhealthy food consumption in children high in reward sensitivity, this study tested the hypothesis that the home availability of unhealthy food moderates the effect of reward sensitivity on children's fast-food consumption frequency, exerted via food cue responsiveness. Children between 7.5 and 14 years (n = 174, 50.6% boys) reported on reward sensitivity and food cue responsiveness (by means of the subscale 'external eating'). Their height and weight were measured. Parents reported on their children's fast-food consumption frequency, food cue responsiveness (by means of the subscale 'food responsiveness'), and on the home availability of unhealthy foods. Two moderated mediation models were conducted, one with the parent- and one with the child-reported food cue responsiveness as mediator. Findings suggested that with a high home availability of unhealthy foods, (a) a higher fast-food consumption frequency was found in children high in reward sensitivity and (b) the relation between reward sensitivity and the fast-food consumption frequency was mediated by external eating. The findings point at the importance of the home food environment in children high in reward sensitivity. They suggest to limit the home availability of unhealthy foods. What is Known: • Reward sensitivity (RS) is positively associated with children's palatable food consumption • In adolescents, this effect is mediated by food cue responsiveness, which determines the strength of an individual's motivation to obtain food when perceiving food cues What is New: • Children high in RS may be more vulnerable to palatable food cues in their everyday food environment because of a higher food cue responsiveness • The home food environment may be an important determining factor of the palatable food consumption of these children.
Operator priming and generalization of practice in adults' simple arithmetic.
Chen, Yalin; Campbell, Jamie I D
2016-04-01
There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication, suggesting that a general addition procedure was primed by the + sign. In Experiment 1 (n = 36), we applied this operator-priming paradigm to rule-based problems (0 + N = N, 1 × N = N, 0 × N = 0) and 1 + N problems with N ranging from 0 to 9. For the rule-based problems, we found both operator-preview facilitation and generalization of practice (e.g., practicing 0 + 3 sped up unpracticed 0 + 8), the latter being a signature of procedure use; however, we also found operator-preview facilitation for 1 + N in the absence of generalization, which implies the 1 + N problems were solved by fact retrieval but nonetheless were facilitated by an operator preview. Thus, the operator preview effect does not discriminate procedure use from fact retrieval. Experiment 2 (n = 36) investigated whether a population with advanced mathematical training-engineering and computer science students-would show generalization of practice for nonrule-based simple addition problems (e.g., 1 + 4, 4 + 7). The 0 + N problems again presented generalization, whereas no nonzero problem type did; but all nonzero problems sped up when the identical problems were retested, as predicted by item-specific fact retrieval. The results pose a strong challenge to the generality of the proposal that skilled adults' simple addition is based on fast procedural algorithms, and instead support a fact-retrieval model of fast addition performance. (c) 2016 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Fu, Guangwei; Li, Qifeng; Li, Yunpu; Yang, Jiandong; Fu, Xinghu; Bi, Weihong; Li, Yanjun
2016-10-01
A tension sensor of Photonic Crystal Fiber(PCF) is presented based on core-offset splicing and waist-enlarged fiber taper. The tension response characteristics of the sensor are studied experimentally. To analyzing the modal interference, many samples with different PCF lengths between the two splicing areas, different core-offset distances and different waist-enlarged fiber taper diameters are fabricated and tested. When the tension range is 0 to 4000μɛ, the results show that the spectrum is blue shift with the increasing of the axial tension. The sensitivity is-2.1 pm/μɛ. The experimental results show that the tension sensitivity can be not influenced by the PCF lengths, the core-offset distances.The waist-enlarged fiber taper diameters and the tension sensor is very sensitive to axial tension and the relationship between the wavelength shift and tension is linearity. To determine the number of the interfering modes, the transmission spectra of these sensor is transformed by the fast fourier transform (FFT) method. There are several peaks in the spatial frequency spectra at these sensors. Only one cladding mode is dominantly excited, while the other cladding modes are weak. The spatial frequency is proportional to the differential mode group index. Compared with the traditional fiber sensor, this sensor has some advantages including the easily fabricated, simple structure and high sensitivity. It can be used in industrial production, building monitoring, aerospace and other fields.
Zhang, Hongwei; Gao, Lan; Shu, Menglin; Liu, Jihua; Yu, Boyang
2018-01-15
l-Corydalmine (l-CDL) is a potent analgesic constituent of the traditional Chinese medicine, Rhizoma Corydalis. However, the pharmacokinetic process and tissue distribution of l-CDL in vivo are still unknown. Therefore, it is necessary to establish a simple and sensitive method to detect l-CDL, which will be helpful to study its distribution and pharmacokinetic process. To determine this compound in biological samples, a monoclonal antibody (mAb) against l-CDL was produced and a fast and highly sensitive indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed in this study. The icELISA was applied to determine l-CDL in biological samples. The limit of detection (LOD) of the method was 0.015 ng/mL with a liner range of 1-1000 ng/mL (R 2 = 0.9912). The intra- and inter-day precision were below 15% and the recoveries were within 80-117%. Finally, the developed immunoassay was successfully applied to the analysis of the distribution of l-CDL in SD rats. In conclusion, the icELISA based on the anti-l-CDL mAb could be considered as a highly sensitive and rapid method for the determination of l-CDL in biological samples. The ELISA approach may provide a valuable tool for the analysis of small molecules in biological samples. Copyright © 2017. Published by Elsevier B.V.
de Oliveira, Marcelo Firmino; Vieira, Andressa Tironi; Batista, Antônio Carlos Ferreira; Rodrigues, Hugo de Souza; Stradiotto, Nelson Ramos
2011-01-01
A simple, fast, and complete route for the production of methylic and ethylic biodiesel from tucum oil is described. Aliquots of the oil obtained directly from pressed tucum (pulp and almonds) were treated with potassium methoxide or ethoxide at 40°C for 40 min. The biodiesel form was removed from the reactor and washed with 0.1 M HCl aqueous solution. A simple distillation at 100°C was carried out in order to remove water and alcohol species from the biodiesel. The oxidative stability index was obtained for the tucum oil as well as the methylic and ethylic biodiesel at 6.13, 2.90, and 2.80 h, for storage times higher than 8 days. Quality control of the original oil and of the methylic and ethylic biodiesels, such as the amount of glycerin produced during the transesterification process, was accomplished by the TLC, GC-MS, and FT-IR techniques. The results obtained in this study indicate a potential biofuel production by simple treatment of tucum, an important Amazonian fruit. PMID:21629751
Pujol-Vila, F; Vigués, N; Díaz-González, M; Muñoz-Berbel, X; Mas, J
2015-05-15
Global urban and industrial growth, with the associated environmental contamination, is promoting the development of rapid and inexpensive general toxicity methods. Current microbial methodologies for general toxicity determination rely on either bioluminescent bacteria and specific medium solution (i.e. Microtox(®)) or low sensitivity and diffusion limited protocols (i.e. amperometric microbial respirometry). In this work, fast and sensitive optical toxicity bioassay based on dual wavelength analysis of bacterial ferricyanide reduction kinetics is presented, using Escherichia coli as a bacterial model. Ferricyanide reduction kinetic analysis (variation of ferricyanide absorption with time), much more sensitive than single absorbance measurements, allowed for direct and fast toxicity determination without pre-incubation steps (assay time=10 min) and minimizing biomass interference. Dual wavelength analysis at 405 (ferricyanide and biomass) and 550 nm (biomass), allowed for ferricyanide monitoring without interference of biomass scattering. On the other hand, refractive index (RI) matching with saccharose reduced bacterial light scattering around 50%, expanding the analytical linear range in the determination of absorbent molecules. With this method, different toxicants such as metals and organic compounds were analyzed with good sensitivities. Half maximal effective concentrations (EC50) obtained after 10 min bioassay, 2.9, 1.0, 0.7 and 18.3 mg L(-1) for copper, zinc, acetic acid and 2-phenylethanol respectively, were in agreement with previously reported values for longer bioassays (around 60 min). This method represents a promising alternative for fast and sensitive water toxicity monitoring, opening the possibility of quick in situ analysis. Copyright © 2014 Elsevier B.V. All rights reserved.
Voltage-Sensitive Fluorescence of Indocyanine Green in the Heart
Martišienė, Irma; Mačianskienė, Regina; Treinys, Rimantas; Navalinskas, Antanas; Almanaitytė, Mantė; Karčiauskas, Dainius; Kučinskas, Audrius; Grigalevičiūtė, Ramunė; Zigmantaitė, Vilma; Benetis, Rimantas; Jurevičius, Jonas
2016-01-01
So far, the optical mapping of cardiac electrical signals using voltage-sensitive fluorescent dyes has only been performed in experimental studies because these dyes are not yet approved for clinical use. It was recently reported that the well-known and widely used fluorescent dye indocyanine green (ICG), which has FDA approval, exhibits voltage sensitivity in various tissues, thus raising hopes that electrical activity could be optically mapped in the clinic. The aim of this study was to explore the possibility of using ICG to monitor cardiac electrical activity. Optical mapping experiments were performed on Langendorff rabbit hearts stained with ICG and perfused with electromechanical uncouplers. The residual contraction force and electrical action potentials were recorded simultaneously. Our research confirms that ICG is a voltage-sensitive dye with a dual-component (fast and slow) response to membrane potential changes. The fast component of the optical signal (OS) can have opposite polarities in different parts of the fluorescence spectrum. In contrast, the polarity of the slow component remains the same throughout the entire spectrum. Separating the OS into these components revealed two different voltage-sensitivity mechanisms for ICG. The fast component of the OS appears to be electrochromic in nature, whereas the slow component may arise from the redistribution of the dye molecules within or around the membrane. Both components quite accurately track the time of electrical signal propagation, but only the fast component is suitable for estimating the shape and duration of action potentials. Because ICG has voltage-sensitive properties in the entire heart, we suggest that it can be used to monitor cardiac electrical behavior in the clinic. PMID:26840736
Insulin resistance in obesity can be reliably identified from fasting plasma insulin.
ter Horst, K W; Gilijamse, P W; Koopman, K E; de Weijer, B A; Brands, M; Kootte, R S; Romijn, J A; Ackermans, M T; Nieuwdorp, M; Soeters, M R; Serlie, M J
2015-12-01
Insulin resistance is the major contributor to cardiometabolic complications of obesity. We aimed to (1) establish cutoff points for insulin resistance from euglycemic hyperinsulinemic clamps (EHCs), (2) identify insulin-resistant obese subjects and (3) predict insulin resistance from routinely measured variables. We assembled data from non-obese (n=112) and obese (n=100) men who underwent two-step EHCs using [6,6-(2)H2]glucose as tracer (insulin infusion dose 20 and 60 mU m(-2) min(-1), respectively). Reference ranges for hepatic and peripheral insulin sensitivity were calculated from healthy non-obese men. Based on these reference values, obese men with preserved insulin sensitivity or insulin resistance were identified. Cutoff points for insulin-mediated suppression of endogenous glucose production (EGP) and insulin-stimulated glucose disappearance rate (Rd) were 46.5% and 37.3 μmol kg(-)(1) min(-)(1), respectively. Most obese men (78%) had EGP suppression within the reference range, whereas only 12% of obese men had Rd within the reference range. Obese men with Rd <37.3 μmol kg(-1) min(-1) did not differ from insulin-sensitive obese men in age, body mass index (BMI), body composition, fasting glucose or cholesterol, but did have higher fasting insulin (110±49 vs 63±29 pmol l(-1), P<0.001) and homeostasis model assessment of insulin resistance (HOMA-IR) (4.5±2.2 vs 2.7±1.4, P=0.004). Insulin-resistant obese men could be identified with good sensitivity (80%) and specificity (75%) from fasting insulin >74 pmol l(-1). Most obese men have hepatic insulin sensitivity within the range of non-obese controls, but below-normal peripheral insulin sensitivity, that is, insulin resistance. Fasting insulin (>74 pmol l(-1) with current insulin immunoassay) may be used for identification of insulin-resistant (or metabolically unhealthy) obese men in research and clinical settings.
Fast and accurate image recognition algorithms for fresh produce food safety sensing
NASA Astrophysics Data System (ADS)
Yang, Chun-Chieh; Kim, Moon S.; Chao, Kuanglin; Kang, Sukwon; Lefcourt, Alan M.
2011-06-01
This research developed and evaluated the multispectral algorithms derived from hyperspectral line-scan fluorescence imaging under violet LED excitation for detection of fecal contamination on Golden Delicious apples. The algorithms utilized the fluorescence intensities at four wavebands, 680 nm, 684 nm, 720 nm, and 780 nm, for computation of simple functions for effective detection of contamination spots created on the apple surfaces using four concentrations of aqueous fecal dilutions. The algorithms detected more than 99% of the fecal spots. The effective detection of feces showed that a simple multispectral fluorescence imaging algorithm based on violet LED excitation may be appropriate to detect fecal contamination on fast-speed apple processing lines.
Gubner, N R; McKinnon, C S; Reed, C; Phillips, T J
2013-01-01
Co-morbid use of nicotine-containing tobacco products and alcohol is prevalent in alcohol dependent individuals. Common genetic factors could influence initial sensitivity to the independent or interactive effects of these drugs and play a role in their co-abuse. Locomotor sensitivity to nicotine and ethanol, alone and in combination, was assessed in mice bred for high (FAST) and low (SLOW) sensitivity to the locomotor stimulant effects of ethanol and in an inbred strain of mouse (DBA/2J) that has been shown to have extreme sensitivity to ethanol-induced stimulation in comparison to other strains. The effects of nicotine and ethanol, alone and in combination, were dependent on genotype. In FAST and DBA/2J mice that show high sensitivity to ethanol-induced stimulation, nicotine accentuated the locomotor stimulant response to ethanol. This effect was not found in SLOW mice that are not stimulated by ethanol alone. These data indicate that genes underlying differential sensitivity to the stimulant effects of ethanol alone also influence sensitivity to nicotine in combination with ethanol. Sensitivity to the stimulant effects of nicotine alone does not appear to predict the response to the drug combination, as FAST mice are sensitive to nicotine-induced stimulation, whereas SLOW and DBA/2J mice are not. The combination of nicotine and ethanol may have genotype-dependent effects that could impact co-abuse liability. Published by Elsevier Ireland Ltd.
Oldrini, Guillaume; Fedida, Benjamin; Poujol, Julie; Felblinger, Jacques; Trop, Isabelle; Henrot, Philippe; Darai, Emile; Thomassin-Naggara, Isabelle
2017-10-01
To evaluate the added value of ULTRAFAST-MR sequence to an abbreviated FAST protocol in comparison with FULL protocol to distinguish benign from malignant lesions in a population of women, regardless of breast MR imaging indication. From March 10th to September 22th, 2014, we retrospectively included a total of 70 consecutive patients with 106 histologically proven lesions (58 malignant and 48 benign) who underwent breast MR imaging for preoperative breast staging (n=38), high-risk screening (n=7), problem solving (n=18), and nipple discharge (n=4) with 12 time resolved imaging of contrast kinetics (TRICKS) acquisitions during contrast inflow interleaved in a regular high-resolution dynamic MRI protocol (FULL protocol). Two readers scored MR exams as either positive or negative and described significant lesions according to Bi-RADS lexicon with a TRICKS images (ULTRAFAST), an abbreviated protocol (FAST) and all images (FULL protocol). Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated for each protocol and compared with McNemar's test. For all readers, the combined FAST-ULTRAFAST protocol significantly improved the reading with a specificity of 83.3% and 70.8% in comparison with FAST protocol or FULL protocol, respectively, without change in sensitivity. By adding ULTRAFAST protocol to FAST protocol, readers 1 and 2 were able to correctly change the diagnosis in 22.9% (11/48) and 10.4% (5/48) of benign lesions, without missing any malignancy, respectively. Both interpretation and image acquisition times for combined FAST-ULTRAFAST protocol and FAST protocol were shorter compared to FULL protocol (p<0.001). Compared to FULL protocol, adding ULTRAFAST to FAST protocol improves specificity, mainly in correctly reclassifying benign masses and reducing interpretation and acquisition time, without decreasing sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.
Vogeser, Michael; König, Daniel; Frey, Ingrid; Predel, Hans-Georg; Parhofer, Klaus Georg; Berg, Aloys
2007-09-01
Lifestyle changes with increased physical activity and balanced energy intake are recognized as the principal interventions in obesity and insulin resistance. Only few prospective studies, however, have so far addressed the potential role of routine biochemical markers of insulin sensitivity in the monitoring of respective interventions. Fasting insulin and glucose was measured in 33 obese individuals undergoing a lifestyle modification program (MOBILIS) at baseline and after 1 year. The HOMA-IR index (homeostasis model of insulin resistance) was calculated as [fasting serum glucose*fasting serum insulin/22.5], with lower values indicating a higher degree of insulin sensitivity. While the median body mass index (BMI) and waist circumference decreased by 10% and 11%, respectively, the HOMA-IR index decreased in an over-proportional manner by 45% within 1 year (BMI baseline, median 35.7, interquartile range (IQR) 33.7-37.7; after 1 year, median 32.2, IQR 29.6-35.1. HOMA-IR baseline, median 2.9, IQR 1.5-4.6; after 1 year 1.6, IQR 0.9-2.7). In contrast to HOMA-IR and fasting serum insulin, no significant changes in fasting serum glucose were observed. Baseline and post-intervention HOMA-IR showed a high degree of inter-individual variation with eight individuals maintaining high HOMA-IR values despite weight loss after 1 year of intervention. Individual changes in the carbohydrate metabolism achieved by a lifestyle intervention program were displayed by fasting serum insulin concentrations and the HOMA-IR but not by fasting glucose measurement alone. Therefore, assessment of the HOMA-IR may help to individualize lifestyle interventions in obesity and to objectify improvements in insulin sensitivity after therapeutic lifestyle changes.
Fasting glycaemia to simplify screening for gestational diabetes.
Ryser Rüetschi, J; Jornayvaz, F R; Rivest, R; Huhn, E A; Irion, O; Boulvain, M
2016-12-01
Recommendations in Switzerland on screening for gestational diabetes endorse the International Association of Diabetes in Pregnancy Study Group consensus. As universal testing is time consuming and glucose loading is unpleasant, the recommendations include a simplification, not performing the glucose loading in women with fasting glycaemia <4.4 mmol/l. Our objective was to evaluate the diagnostic performance of this simplified strategy, compared with the complete test, in our population with a low prevalence of gestational diabetes. We collected 2298 complete 75-g glucose tolerance tests. We simulated stopping the test, so avoiding the glucose loading and further glycaemia, if fasting glycaemia was <4.4 or ≥5.1 mmol/l. Unselected pregnant women from Geneva and Basel, at 24-28 weeks of gestation. We calculated the sensitivity, and the percentage of women who would avoid the complete test with the strategy based on fasting glycaemia. The prevalence of gestational diabetes was 10.9% in our population. Among 251 women with gestational diabetes, fasting glycaemia was ≥5.1 mmol/l in 119 women (47.4%), between 4.4 and <5.1 mmol/l in 78 women (31.1%) and <4.4 mmol/l in 54 women (21.5%). Proceeding with the complete test only in women with fasting glycaemia between 4.4 and <5.1 mmol/l will result in a sensitivity of 78.5%. This strategy would avoid glucose loading in 63.8% of women. Screening with fasting glycaemia is an attractive alternative to universal screening with the complete 75-g glucose tolerance test. This strategy is, however, slightly less sensitive than previously reported in higher-risk populations. Fasting glycaemia can be considered as an alternative to the complete test for gestational diabetes screening. © 2016 Royal College of Obstetricians and Gynaecologists.
Huang, Yuan-sheng; Yang, Zhi-rong; Zhan, Si-yan
2015-06-18
To investigate the use of simple pooling and bivariate model in meta-analyses of diagnostic test accuracy (DTA) published in Chinese journals (January to November, 2014), compare the differences of results from these two models, and explore the impact of between-study variability of sensitivity and specificity on the differences. DTA meta-analyses were searched through Chinese Biomedical Literature Database (January to November, 2014). Details in models and data for fourfold table were extracted. Descriptive analysis was conducted to investigate the prevalence of the use of simple pooling method and bivariate model in the included literature. Data were re-analyzed with the two models respectively. Differences in the results were examined by Wilcoxon signed rank test. How the results differences were affected by between-study variability of sensitivity and specificity, expressed by I2, was explored. The 55 systematic reviews, containing 58 DTA meta-analyses, were included and 25 DTA meta-analyses were eligible for re-analysis. Simple pooling was used in 50 (90.9%) systematic reviews and bivariate model in 1 (1.8%). The remaining 4 (7.3%) articles used other models pooling sensitivity and specificity or pooled neither of them. Of the reviews simply pooling sensitivity and specificity, 41(82.0%) were at the risk of wrongly using Meta-disc software. The differences in medians of sensitivity and specificity between two models were both 0.011 (P<0.001, P=0.031 respectively). Greater differences could be found as I2 of sensitivity or specificity became larger, especially when I2>75%. Most DTA meta-analyses published in Chinese journals(January to November, 2014) combine the sensitivity and specificity by simple pooling. Meta-disc software can pool the sensitivity and specificity only through fixed-effect model, but a high proportion of authors think it can implement random-effect model. Simple pooling tends to underestimate the results compared with bivariate model. The greater the between-study variance is, the more likely the simple pooling has larger deviation. It is necessary to increase the knowledge level of statistical methods and software for meta-analyses of DTA data.
Tabaraki, Reza; Abdi, Omran; Yousefipour, Sedigheh
2017-03-01
A green and simple microwave-assisted method was used to synthesis water-soluble boron and nitrogen-co-doped carbon dots (B-N-CDs). These B-N-CDs were successfully used for the fluorescent determination of Sn 4+ and Mo 6+ ions. This probe had a fast response time at pH = 4 with high sensitivity and selectivity. Linear correlation between F 0 /F and the concentration was seen in the range of 0.2-18 μM and 0.2-25 μM for Sn 4+ and Mo 6+ , respectively. Under optimum condition, the limit of detection (LOD) for Sn 4+ and Mo 6+ were 150 nM and 132 nM, respectively. The performance of the sensor was evaluated by different real samples such as tap, river and mineral water, canned fish sample and tomato samples.
Dekiff, Markus; Berssenbrügge, Philipp; Kemper, Björn; Denz, Cornelia; Dirksen, Dieter
2015-12-01
A metrology system combining three laser speckle measurement techniques for simultaneous determination of 3D shape and micro- and macroscopic deformations is presented. While microscopic deformations are determined by a combination of Digital Holographic Interferometry (DHI) and Digital Speckle Photography (DSP), macroscopic 3D shape, position and deformation are retrieved by photogrammetry based on digital image correlation of a projected laser speckle pattern. The photogrammetrically obtained data extend the measurement range of the DHI-DSP system and also increase the accuracy of the calculation of the sensitivity vector. Furthermore, a precise assignment of microscopic displacements to the object's macroscopic shape for enhanced visualization is achieved. The approach allows for fast measurements with a simple setup. Key parameters of the system are optimized, and its precision and measurement range are demonstrated. As application examples, the deformation of a mandible model and the shrinkage of dental impression material are measured.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, J.C.A.; Hsu, C.Y.; Taiwan SPIN Research Center, National Chung Cheng University, Chiayi, Taiwan
2004-12-13
Proper as well as under- and over-oxided CoFe-AlO{sub x}-CoFe magnetic tunnel junctions (MTJs) have been systematically investigated in a frequency range from 10{sup 2} to 10{sup 8} Hz by complex capacitance spectroscopy. The dielectric relaxation behavior of the MTJs remarkably disobeys the typical Cole-Cole arc law probably due to the existence of imperfectly blocked Schottky barrier in the metal-insulator interface. The dielectric relaxation response can be successfully modeled on the basis of Debye relaxation by incorporating an interfacial dielectric contribution. In addition, complex capacitance spectroscopy demonstrates significant sensitivity to the oxidation process of metallic Al layers, i.e., almost a fingerprintmore » of under, proper, and over oxidation. This technique provides a fast and simple method to inspect the AlO{sub x} barrier quality of MTJs.« less
Resonance light scattering determination of 6-mercaptopurine coupled with HPLC technique
NASA Astrophysics Data System (ADS)
Li, Ai Ping; Peng, Jing Dong; Zhou, MingQiong; Zhang, Jin
2016-02-01
A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH 5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λex = λem = 315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 μg L- 1 and the limit of detection (S/N = 3) was 0.05 μg L- 1. The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed.
Laser controlled atom source for optical clocks.
Kock, Ole; He, Wei; Świerad, Dariusz; Smith, Lyndsie; Hughes, Joshua; Bongs, Kai; Singh, Yeshpal
2016-11-18
Precision timekeeping has been a driving force in innovation, from defining agricultural seasons to atomic clocks enabling satellite navigation, broadband communication and high-speed trading. We are on the verge of a revolution in atomic timekeeping, where optical clocks promise an over thousand-fold improvement in stability and accuracy. However, complex setups and sensitivity to thermal radiation pose limitations to progress. Here we report on an atom source for a strontium optical lattice clock which circumvents these limitations. We demonstrate fast (sub 100 ms), cold and controlled emission of strontium atomic vapours from bulk strontium oxide irradiated by a simple low power diode laser. Our results demonstrate that millions of strontium atoms from the vapour can be captured in a magneto-optical trap (MOT). Our method enables over an order of magnitude reduction in scale of the apparatus. Future applications range from satellite clocks testing general relativity to portable clocks for inertial navigation systems and relativistic geodesy.
Immunoanalysis Methods for the Detection of Dioxins and Related Chemicals
Tian, Wenjing; Xie, Heidi Qunhui; Fu, Hualing; Pei, Xinhui; Zhao, Bin
2012-01-01
With the development of biotechnology, approaches based on antibodies, such as enzyme-linked immunosorbent assay (ELISA), active aryl hydrocarbon immunoassay (Ah-I) and other multi-analyte immunoassays, have been utilized as alternatives to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of dioxin and dioxin-like compounds in environmental and biological samples. These screening methods have been verified as rapid, simple and cost-effective. This paper provides an overview on the development and application of antibody-based approaches, such as ELISA, Ah-I, and multi-analyte immunoassays, covering the sample extraction and cleanup, antigen design, antibody preparation and immunoanalysis. However, in order to meet the requirements for on-site fast detection and relative quantification of dioxins in the environment, further optimization is needed to make these immuno-analytical methods more sensitive and easy to use. PMID:23443395
Resonance light scattering determination of 6-mercaptopurine coupled with HPLC technique.
Li, Ai Ping; Peng, Jing Dong; Zhou, MingQiong; Zhang, Jin
2016-02-05
A simple, fast, costless, sensitive and selective method of resonance light scattering coupled with HPLC was established for the determination of 6-mercaptopurine in human urine sample. In a Britton-Robinson buffer solution of pH5.5, the formation of coordination complex between 6-mercaptopurine and metal palladium (II) led to enhance the RLS intensity of the system. The RLS signal was detected by fluorescence detector at λ(ex)=λ(em)=315 nm. The analytical parameters were provided by the coupled system, the linear of 6-mercaptopurine response from 0.0615 to 2.40 μg L(-1) and the limit of detection (S/N=3) was 0.05 μg L(-1). The presented method has been applied to determine 6-mercaptopurine in human urine samples which obtained satisfactory results. Moreover, the reaction mechanism and possible reasons for enhancement of RLS were fully discussed. Copyright © 2015 Elsevier B.V. All rights reserved.
Langevin, Stanley A.; Bent, Zachary W.; Solberg, Owen D.; Curtis, Deanna J.; Lane, Pamela D.; Williams, Kelly P.; Schoeniger, Joseph S.; Sinha, Anupama; Lane, Todd W.; Branda, Steven S.
2013-01-01
Use of second generation sequencing (SGS) technologies for transcriptional profiling (RNA-Seq) has revolutionized transcriptomics, enabling measurement of RNA abundances with unprecedented specificity and sensitivity and the discovery of novel RNA species. Preparation of RNA-Seq libraries requires conversion of the RNA starting material into cDNA flanked by platform-specific adaptor sequences. Each of the published methods and commercial kits currently available for RNA-Seq library preparation suffers from at least one major drawback, including long processing times, large starting material requirements, uneven coverage, loss of strand information and high cost. We report the development of a new RNA-Seq library preparation technique that produces representative, strand-specific RNA-Seq libraries from small amounts of starting material in a fast, simple and cost-effective manner. Additionally, we have developed a new quantitative PCR-based assay for precisely determining the number of PCR cycles to perform for optimal enrichment of the final library, a key step in all SGS library preparation workflows. PMID:23558773
NASA Astrophysics Data System (ADS)
Yu, Jiajia; He, Yong
Mango is a kind of popular tropical fruit, and the soluble solid content is an important in this study visible and short-wave near-infrared spectroscopy (VIS/SWNIR) technique was applied. For sake of investigating the feasibility of using VIS/SWNIR spectroscopy to measure the soluble solid content in mango, and validating the performance of selected sensitive bands, for the calibration set was formed by 135 mango samples, while the remaining 45 mango samples for the prediction set. The combination of partial least squares and backpropagation artificial neural networks (PLS-BP) was used to calculate the prediction model based on raw spectrum data. Based on PLS-BP, the determination coefficient for prediction (Rp) was 0.757 and root mean square and the process is simple and easy to operate. Compared with the Partial least squares (PLS) result, the performance of PLS-BP is better.
Hu, Chaofan; Jia, Li; Liu, Qingqing; Zhang, Sheng
2010-07-01
A sensitive, fast and simple method based on magnetic octadecylsilane particles was developed for the extraction of three fat-soluble vitamins followed by capillary LC (CLC) analysis with UV detection. Magnetic octadecylsilane particles were prepared based on three-step reactions including co-precipitation, sol-gel polymerization and alkylation. The characterization of the prepared product was studied by scanning electron microscope and Fourier-transform infrared spectrometry. The particles were used as magnetic SPE adsorbent for the extraction of fat-soluble vitamins in fruit juice-milk beverage. The extraction condition and efficiency of the particles for fat-soluble vitamins were investigated. By coupling magnetic SPE with capillary LC with UV detection, low concentrations of fat-soluble vitamins in fruit juice-milk beverage can be detected without the interference from other substances in the sample matrix.
Measurement and analysis of critical crack tip processes during fatigue crack growth
NASA Technical Reports Server (NTRS)
Davidson, D. L.; Hudak, S. J.; Dexter, R. J.
1985-01-01
The mechanics of fatigue crack growth under constant-amplitudes and variable-amplitude loading were examined. Critical loading histories involving relatively simple overload and overload/underload cycles were studied to provide a basic understanding of the underlying physical processes controlling crack growth. The material used for this study was 7091-T7E69, a powder metallurgy aluminum alloy. Local crack-tip parameters were measured at various times before, during, and after the overloads, these include crack-tip opening loads and displacements, and crack-tip strain fields. The latter were useed, in combination with the materials cyclic and monotonic stress-strain properties, to compute crack-tip residual stresses. The experimental results are also compared with analytical predictions obtained using the FAST-2 computer code. The sensitivity of the analytical model to constant-amplitude fatigue crack growth rate properties and to through-thickness constrain are studied.
Two-photon imaging of spatially extended neuronal network dynamics with high temporal resolution.
Lillis, Kyle P; Eng, Alfred; White, John A; Mertz, Jerome
2008-07-30
We describe a simple two-photon fluorescence imaging strategy, called targeted path scanning (TPS), to monitor the dynamics of spatially extended neuronal networks with high spatiotemporal resolution. Our strategy combines the advantages of mirror-based scanning, minimized dead time, ease of implementation, and compatibility with high-resolution low-magnification objectives. To demonstrate the performance of TPS, we monitor the calcium dynamics distributed across an entire juvenile rat hippocampus (>1.5mm), at scan rates of 100 Hz, with single cell resolution and single action potential sensitivity. Our strategy for fast, efficient two-photon microscopy over spatially extended regions provides a particularly attractive solution for monitoring neuronal population activity in thick tissue, without sacrificing the signal-to-noise ratio or high spatial resolution associated with standard two-photon microscopy. Finally, we provide the code to make our technique generally available.
NASA Astrophysics Data System (ADS)
Azad, Saeed; Sadeghi, Ebrahim; Parvizi, Roghaieh; Mazaheri, Azardokht; Yousefi, M.
2017-05-01
In this work, the multimode optical fiber size effects on the performances of the clad-modified fiber with ZnO nanorods relative humidity (RH) sensor were experimentally investigated. Simple and controlled chemical etching method through on line monitoring was used to prepare different fiber waist diameter with long length of 15 mm. More precisely, the competition behavior of sensor performances with varying fiber waist diameter was studied to find appropriate size of maximizing evanescent fields. The obtained results revealed that evanescent wave absorption coefficient (γ) enhanced more than 10 times compare to bare fiber at the proposed optimum fiber diameter of 28 μm. Also, high linearity and fast recovery time about 7 s was obtained at the proposed fiber waist diameter. Applicable features of the proposed sensor allow this device to be used for humidity sensing applications, especially to be applied in remote sensing technologies.
Reconfigurable photonic crystals enabled by pressure-responsive shape-memory polymers
Fang, Yin; Ni, Yongliang; Leo, Sin-Yen; Taylor, Curtis; Basile, Vito; Jiang, Peng
2015-01-01
Smart shape-memory polymers can memorize and recover their permanent shape in response to an external stimulus (for example, heat). They have been extensively exploited for a wide spectrum of applications ranging from biomedical devices to aerospace morphing structures. However, most of the existing shape-memory polymers are thermoresponsive and their performance is hindered by heat-demanding programming and recovery steps. Although pressure is an easily adjustable process variable such as temperature, pressure-responsive shape-memory polymers are largely unexplored. Here we report a series of shape-memory polymers that enable unusual ‘cold' programming and instantaneous shape recovery triggered by applying a contact pressure at ambient conditions. Moreover, the interdisciplinary integration of scientific principles drawn from two disparate fields—the fast-growing photonic crystal and shape-memory polymer technologies—enables fabrication of reconfigurable photonic crystals and simultaneously provides a simple and sensitive optical technique for investigating the intriguing shape-memory effects at nanoscale. PMID:26074349
Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar
2015-12-01
In present study, a simultaneous derivatization and air-assisted liquid-liquid microextraction method combined with gas chromatography-nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1-flouro-2,4-dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05-0.34 ng mL(-1) are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd.
Laser controlled atom source for optical clocks
Kock, Ole; He, Wei; Świerad, Dariusz; Smith, Lyndsie; Hughes, Joshua; Bongs, Kai; Singh, Yeshpal
2016-01-01
Precision timekeeping has been a driving force in innovation, from defining agricultural seasons to atomic clocks enabling satellite navigation, broadband communication and high-speed trading. We are on the verge of a revolution in atomic timekeeping, where optical clocks promise an over thousand-fold improvement in stability and accuracy. However, complex setups and sensitivity to thermal radiation pose limitations to progress. Here we report on an atom source for a strontium optical lattice clock which circumvents these limitations. We demonstrate fast (sub 100 ms), cold and controlled emission of strontium atomic vapours from bulk strontium oxide irradiated by a simple low power diode laser. Our results demonstrate that millions of strontium atoms from the vapour can be captured in a magneto-optical trap (MOT). Our method enables over an order of magnitude reduction in scale of the apparatus. Future applications range from satellite clocks testing general relativity to portable clocks for inertial navigation systems and relativistic geodesy. PMID:27857214
A method for the microlensed flux variance of QSOs
NASA Astrophysics Data System (ADS)
Goodman, Jeremy; Sun, Ai-Lei
2014-06-01
A fast and practical method is described for calculating the microlensed flux variance of an arbitrary source by uncorrelated stars. The required inputs are the mean convergence and shear due to the smoothed potential of the lensing galaxy, the stellar mass function, and the absolute square of the Fourier transform of the surface brightness in the source plane. The mathematical approach follows previous authors but has been generalized, streamlined, and implemented in publicly available code. Examples of its application are given for Dexter and Agol's inhomogeneous-disc models as well as the usual Gaussian sources. Since the quantity calculated is a second moment of the magnification, it is only logarithmically sensitive to the sizes of very compact sources. However, for the inferred sizes of actual quasi-stellar objects (QSOs), it has some discriminatory power and may lend itself to simple statistical tests. At the very least, it should be useful for testing the convergence of microlensing simulations.
Kong, Xianghong; He, Qiang; Yue, Aishan; Wu, Shuangmin; Li, Jianhua
2010-06-01
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of arbutin in apple juice concentrate. Samples were diluted with water, then cleaned-up with a PS-DVB column. Quantitation was carried out using an external standard method. UPLC was performed on an Eclipse Plus C, column (100 mm x 2.1 mm, 1.8 microm) using a gradient solvent system (methanol-water). MS/MS was performed with multiple reaction monitoring (MRM) mode. The detection limit of arbutin was 0.02 mg/L. The method showed good linear relationship at the range of 0.04-2.0 mg/L. The recoveries ranged from 75.2% to 102.7% with relative standard deviations (RSDs) less than 8.9%. The method is simple, fast and sensitive. It's suitable for quantitative and qualitative analysis of arbutin in apple juice concentrate.
Micro-machined thermo-conductivity detector
Yu, Conrad
2003-01-01
A micro-machined thermal conductivity detector for a portable gas chromatograph. The detector is highly sensitive and has fast response time to enable detection of the small size gas samples in a portable gas chromatograph which are in the order of nanoliters. The high sensitivity and fast response time are achieved through micro-machined devices composed of a nickel wire, for example, on a silicon nitride window formed in a silicon member and about a millimeter square in size. In addition to operating as a thermal conductivity detector, the silicon nitride window with a micro-machined wire therein of the device can be utilized for a fast response heater for PCR applications.
Detection and Proportion of Very Early Dental Caries in Independent Living Older Adults
Holtzman, Jennifer S.; Kohanchi, Daniel; Biren-Fetz, John; Fontana, Margherita; Ramchandani, Manisha; Osann, Kathryn; Hallajian, Lucy; Mansour, Stephanie; Nabelsi, Tasneem; Chung, Na Eun; Wilder-Smith, Petra
2015-01-01
Background and Objectives Dental caries is an important healthcare challenge in adults over 65 years of age. Integration of oral health screening into non-dental primary care practice may improve access to preventive dental care for vulnerable populations such as the elderly. Such integration would require easy, fast, and accurate early caries detection tools. Primary goal of this study was to evaluate the diagnostic performance of optical coherence tomography (OCT) imaging for detecting very early caries in the elderly living in community-based settings. The International Caries Detection and Assessment System (ICDAS) served as gold standard. Secondary goal of this study was to provide baseline prevalence data of very early caries lesions in independent living adults aged 65+ years. Materials and Methods Seventy-two subjects were recruited from three sites in Southern California: a retirement community, a senior health fair, and a convalescent hospital. Clinical examination was performed using the ICDAS visual criteria and this was followed by OCT imaging. The two-dimensional OCT images (B-scan) were analyzed with simple software. Locations with a log of back-scattered light intensity (BSLI) below 2.9 were scored as sound, and areas equaling or exceeding 2.9 BSLI were considered carious. Diagnostic performance of OCT imaging was compared with ICDAS score. Results OCT-based diagnosis demonstrated very good sensitivity (95.1%) and good specificity (85.8%). 54.7% of dentate subjects had at least one tooth with very early coronal caries. Conclusions Early coronal decay is prevalent in the unrestored pits and fissures of coronal surfaces of teeth in independent living adults aged 65+ years. Though OCT imaging coupled with a simple diagnostic algorithm can accurately detect areas of very early caries in community-based settings, existing devices are expensive and not well-suited for use by non-dental health care providers. Simple, inexpensive, fast, and accurate tools for early caries detection by field health care providers working in non-traditional settings are urgently needed to support inter-professional dental health management. Lasers Surg. PMID:26414887
Highly Selective and Rapid Breath Isoprene Sensing Enabled by Activated Alumina Filter.
van den Broek, Jan; Güntner, Andreas T; Pratsinis, Sotiris E
2018-03-23
Isoprene is a versatile breath marker for noninvasive monitoring of high blood cholesterol levels as well as for influenza, end-stage renal disease, muscle activity, lung cancer, and liver disease with advanced fibrosis. Its selective detection in complex human breath by portable devices (e.g., metal-oxide gas sensors), however, is still challenging. Here, we present a new filter concept based on activated alumina powder enabling fast and highly selective detection of isoprene at the ppb level and high humidity. The filter contains high surface area adsorbents that retain hydrophilic compounds (e.g., ketones, alcohols, ammonia) representing major interferants in breath while hydrophobic isoprene is not affected. As a proof-of-concept, filters of commercial activated alumina powder are combined with highly sensitive but rather nonspecific, nanostructured Pt-doped SnO 2 sensors. This results in fast (10 s) measurement of isoprene down to 5 ppb at 90% relative humidity with outstanding selectivity (>100) to breath-relevant acetone, ammonia, ethanol, and methanol, superior to state-of-the-art isoprene sensors. Most importantly, when exposed continuously to simulated breath mixtures (four analytes) for 8 days, this filter-sensor system showed stable performance. It can be incorporated readily into a portable breath isoprene analyzer promising for simple-in-use monitoring of blood cholesterol or other patho/physiological conditions.
Gräsbeck, Ralph; Tanner, Stephan M
2011-09-01
Fifty years have passed since the description of juvenile selective malabsorption of cobalamin (Cbl). Quality of life improvements have dramatically reduced the incidence of parasite-induced or nutritional Cbl deficiency. Consequently, inherited defects have become a leading cause of Cbl deficiency in children, which is not always expressed as anemia. Unfortunately, the gold standard for clinical diagnosis, the Schilling test, has increasingly become unavailable, and replacement tests are only in their infancy. Genetic testing is complicated by genetic heterogeneity and differential diagnosis. This review documents the history, research, and advances in genetics that have elucidated the causes of juvenile Cbl malabsorption. Genetic research has unearthed many cases in the past decade, mostly in Europe and North America, often among immigrants from the Middle East or North Africa. Lack of suitable clinical testing potentially leaves many patients inadequately diagnosed. The consequences of suboptimal Cbl levels for neurological development are well documented. By raising awareness, we wish to push for fast track development of better clinical tools and suitable genetic testing. Clinical awareness must include attention to ethnicity, a sensitive topic but effective for fast diagnosis. The treatment with monthly parenteral Cbl for life offers a simple and cost-effective solution once proper diagnosis is made.
Zeng, Li-Min; Wang, Hao-Yang; Guo, Yin-Long
2010-03-01
A fast, selective, and sensitive GC-MS method has been developed and validated for the determination of boric acid in the drinking water by derivatization with triethanolamine. This analytic strategy successfully converts the inorganic, nonvolatile boric acid B(OH)(3) present in the drinking water to a volatile triethanolamine borate B(OCH(2)CH(2))(3)N in a quantitative manner, which facilitates the GC measurement. The SIM mode was applied in the analysis and showed high accuracy, specificity, and reproducibility, as well as reducing the matrix effect effectively. The calibration curve was obtained from 0.01 microg/mL to 10.0 microg/mL with a satisfactory correlation coefficient of 0.9988. The limit of detection for boric acid was 0.04 microg/L. Then the method was applied for detection of the amount of boric acid in bottled drinking water and the results are in accordance with the reported concentration value of boric acid. This study offers a perspective into the utility of GC-MS as an alternate quantitative tool for detection of B(OH)(3), even for detection of boron in various other samples by digesting the boron compounds to boric acid. Copyright 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tommasi, J.; Ruggieri, J. M.; Lebrat, J. F.
The latest release (2.1) of the ERANOS code system, using JEF-2.2, JEFF-3.1 and ENDF/B-VI r8 multigroup cross-section libraries is currently being validated on fast reactor critical experiments at CEA-Cadarache (France). This paper briefly presents the library effect studies and the detailed best-estimate validation studies performed up to now as part of the validation process. The library effect studies are performed over a wide range of experimental configurations, using simple model and method options. They yield global trends about the shift from JEF-2.2 to JEFF-3.1 cross-section libraries, that can be related to individual sensitivities and cross-section changes. The more detailed, best-estimate,more » calculations have been performed up to now over three experimental configurations carried out in the MASURCA critical facility at CEA-Cadarache: two cores with a softened spectrum due to large amounts of graphite (MAS1A' and MAS1B), and a core representative of sodium-cooled fast reactors (CIRANO ZONA2A). Calculated values have been compared to measurements, and discrepancies analyzed in detail using perturbation theory. Values calculated with JEFF-3.1 were found to be within 3 standard deviations of the measured values, and at least of the same quality as the JEF-2.2 based results. (authors)« less
Raman-based noninvasive metabolic profile evaluation of in vitro bovine embryos
NASA Astrophysics Data System (ADS)
dos Santos, Érika Cristina; Martinho, Herculano; Annes, Kelly; da Silva, Thais; Soares, Carlos Alexandre; Leite, Roberta Ferreira; Milazzotto, Marcella Pecora
2016-07-01
The timing of the first embryonic cell divisions may predict the ability of an embryo to establish pregnancy. Similarly, metabolic profiles may be markers of embryonic viability. However, in bovine, data about the metabolomics profile of these embryos are still not available. In the present work, we describe Raman-based metabolomic profiles of culture media of bovine embryos with different developmental kinetics (fast x slow) throughout the in vitro culture. The principal component analysis enabled us to classify embryos with different developmental kinetics since they presented specific spectroscopic profiles for each evaluated time point. We noticed that bands at 1076 cm-1 (lipids), 1300 cm-1 (Amide III), and 2719 cm-1 (DNA nitrogen bases) gave the most relevant spectral features, enabling the separation between fast and slow groups. Bands at 1001 cm-1 (phenylalanine) and 2892 cm-1 (methylene group of the polymethylene chain) presented specific patterns related to embryonic stage and can be considered as biomarkers of embryonic development by Raman spectroscopy. The culture media analysis by Raman spectroscopy proved to be a simple and sensitive technique that can be applied with high efficiency to characterize the profiles of in vitro produced bovine embryos with different development kinetics and different stages of development.
Rubino, Stefano; Akhtar, Sultan; Leifer, Klaus
2016-02-01
We present a simple, fast method for thickness characterization of suspended graphene/graphite flakes that is based on transmission electron microscopy (TEM). We derive an analytical expression for the intensity of the transmitted electron beam I 0(t), as a function of the specimen thickness t (t<λ; where λ is the absorption constant for graphite). We show that in thin graphite crystals the transmitted intensity is a linear function of t. Furthermore, high-resolution (HR) TEM simulations are performed to obtain λ for a 001 zone axis orientation, in a two-beam case and in a low symmetry orientation. Subsequently, HR (used to determine t) and bright-field (to measure I 0(0) and I 0(t)) images were acquired to experimentally determine λ. The experimental value measured in low symmetry orientation matches the calculated value (i.e., λ=225±9 nm). The simulations also show that the linear approximation is valid up to a sample thickness of 3-4 nm regardless of the orientation and up to several ten nanometers for a low symmetry orientation. When compared with standard techniques for thickness determination of graphene/graphite, the method we propose has the advantage of being simple and fast, requiring only the acquisition of bright-field images.
The fast kinematic magnetic dynamo and the dissipationless limit
NASA Technical Reports Server (NTRS)
Finn, John M.; Ott, Edward
1990-01-01
The evolution of the magnetic field in models that incorporate chaotic field line stretching, field cancellation, and finite magnetic Reynolds number is examined analytically and numerically. Although the models used here are highly idealized, it is claimed that they display and illustrate typical behavior relevant to fast magnetic dynamic behavior. It is shown, in particular, that consideration of magnetic flux through a finite fixed surface provides a simple and effective way of deducing fast dynamo behavior from the zero resistivity equation. Certain aspects of the fast dynamo problem can thus be reduced to a study of nonlinear dynamic properties of the underlying flow.
Pressure to be Thin and Insulin Sensitivity among Adolescents
Schvey, Natasha A.; Shomaker, Lauren B.; Kelly, Nichole R.; Pickworth, Courtney K.; Cassidy, Omni; Galescu, Ovidiu; Demidowich, Andrew P.; Brady, Sheila M.; Tanofsky-Kraff, Marian; Yanovski, Jack A.
2015-01-01
Purpose Extant research indicates that some of the comorbidities associated with adult obesity may be adversely affected by the stress resulting from negative body image and weight-related teasing. This study examined the association between weight-related pressure and insulin sensitivity in adolescents, who are vulnerable to both weight-based teasing and the onset of metabolic dysregulation. Methods Participants were 215 adolescent healthy volunteers (55% female; 59% White; 35% overweight/obese; M±SD age = 15.4±1.4y), who completed a self-report measure of pressure to be thin from parents, friends, and romantic partners. Fasting blood samples were obtained to assess serum insulin and glucose, which were used to calculate insulin sensitivity; fat mass (kg) and fat-free mass (%) were measured with air displacement plethysmography. Pubertal stage was determined by physical examination. Results Pressure to be thin was positively associated with fasting insulin (p = .01) and negatively associated with insulin sensitivity (p = .02), after controlling for pubertal stage, sex, race, height, fat-free mass, and adiposity. Pressure to be thin was associated with a greater odds of having hyperinsulinemia (fasting insulin ≥ 15 µIU/mL; Odds Ratio (95% CI): 1.65 (1.08–2.50), p = .02), adjusting for the same covariates. Conclusions Results indicate that adolescents perceiving more pressure to be thin have greater elevations of fasting insulin and poorer insulin sensitivity above and beyond the effect of fat mass. Future research is warranted to elucidate the mechanisms responsible for this relationship. PMID:26707232
Hemoglobin detection using carbon dots as a fluorescence probe.
Barati, Ali; Shamsipur, Mojtaba; Abdollahi, Hamid
2015-09-15
Herein, we have described the application of high fluorescent carbon dots (CDs) without any surface modification as a simple and fast responding fluorescence probe for sensitive and selective determination of hemoglobin (Hb) in the presence of H2O2. Although Hb itself was able to quench the fluorescence of CDs, based on the inner filter effect (IFE) of the protein that affects both excitation and emission spectra of CDs, the presence of H2O2 resulted in further improvement of the sensitivity of Hb detection. The assay is based on the reaction of Hb with H2O2 that generates reactive oxygen species including hydroxyl (OH•) and superoxide (O2(•-)) radicals under heme degradation and/or iron release from Hb and the subsequent reaction of hydroxyl radicals, as strong oxidizing agents, with CDs resulting in high fluorescence quenching. The proposed probe was used for determination of Hb in concentration range of 1-100 nM with a detection limit of 0.4 nM. The method was successfully applied to the determination of Hb in human blood samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Sequeira, Filipa; Duarte, Daniel; Bilro, Lúcia; Rudnitskaya, Alisa; Pesavento, Maria; Zeni, Luigi; Cennamo, Nunzio
2016-01-01
We report the optimization of the length of a D-shaped plastic optical fiber (POF) sensor for refractive index (RI) sensing from a numerical and experimental point of view. The sensing principle is based on total internal reflection (TIR). POFs with 1 mm in diameter were embedded in grooves, realized in planar supports with different lengths, and polished to remove the cladding and part of the core. All D-shaped POF sensors were tested using aqueous medium with different refractive indices (from 1.332 to 1.471) through intensity-based configuration. Results showed two different responses. Considering the refractive index (RI) range (1.33–1.39), the sensitivity and the resolution of the sensor were strongly dependent on the sensing region length. The highest sensitivity (resolution of 6.48 × 10−3 refractive index units, RIU) was obtained with 6 cm sensing length. In the RI range (1.41–1.47), the length of the sensing region was not a critical aspect to obtain the best resolution. These results enable the application of this optical platform for chemical and biochemical evanescent field sensing. The sensor production procedure is very simple, fast, and low-cost. PMID:27983608
Flint, Alexander C; Bhandari, Shiv G; Cullen, Sean P; Reddy, Adhikari V; Hsu, Daniel P; Rao, Vivek A; Patel, Minal; Pombra, Jasmeen; Edwards, Nancy J; Chan, Sheila L
2018-02-01
Large artery occlusion (LAO) in ischemic stroke requires recognition and triage to an endovascular stroke treatment center. Noninvasive LAO detection is needed to improve triage. Prospective study to test whether noninvasive cerebral oximetry can detect anterior circulation LAO in acute stroke. Interhemispheric ΔBrSO 2 in LAO was compared with controls. In LAO stroke, mean interhemispheric ΔBrSO 2 was -8.3±5.8% (n=19), compared with 0.4±5.8% in small artery stroke (n=17), 0.4±6.0% in hemorrhagic stroke (n=14), and 0.2±7.5% in subjects without stroke (n=19) ( P <0.001). Endovascular stroke treatment reduced the ΔBrSO 2 in most LAO subjects (16/19). Discrimination of LAO at a -3% ΔBrSO 2 cut had 84% sensitivity and 70% specificity. Addition of the G-FAST clinical score (gaze-face-arm-speech- time) to the BrSO 2 measure had 84% sensitivity and 90% specificity. Noninvasive cerebral oximetry may help detect LAO in ischemic stroke, particularly when combined with a simple clinical scoring system. © 2018 American Heart Association, Inc.
Li, Hongbin; Hou, Huagang; Sucheta, Artur; Williams, Benjamin B.; Lariviere, Jean P.; Khan, Nadeem; Lesniewski, Piotr N.; Swartz, Harold M.
2013-01-01
EPR oximetry using implantable resonators allow measurements at much deeper sites than are possible with surface resonators (> 80 mm vs. 10 mm) and have greater sensitivity at any depth. We report here the development of an improvement of the technique that now enables us to obtain the information from multiple sites and at a variety of depths. The measurements from the various sites are resolved using a simple magnetic field gradient. In the rat brain multi-probe implanted resonators measured pO2 at several sites simultaneously for over 6 months to record under normoxic, hypoxic and hyperoxic conditions. This technique also facilitates measurements in moving parts of the animal such as the heart, because the orientation of the paramagnetic material relative to the sensitive small loop is not altered by the motion. The measured response is very fast, enabling measurements in real time of physiological and pathological changes such as experimental cardiac ischemia in the mouse heart. The technique also is quite useful for following changes in tumor pO2, including applications with simultaneous measurements in tumors and adjacent normal tissues. PMID:20204802
Yu, Xiao-Guang; Li, Yuan-Qing; Zhu, Wei-Bin; Huang, Pei; Wang, Tong-Tong; Hu, Ning; Fu, Shao-Yun
2017-05-25
Melamine sponge, also known as nano-sponge, is widely used as an abrasive cleaner in our daily life. In this work, the fabrication of a wearable strain sensor for human motion detection is first demonstrated with a commercially available nano-sponge as a starting material. The key resistance sensitive material in the wearable strain sensor is obtained by the encapsulation of a carbonized nano-sponge (CNS) with silicone resin. The as-fabricated CNS/silicone sensor is highly sensitive to strain with a maximum gauge factor of 18.42. In addition, the CNS/silicone sensor exhibits a fast and reliable response to various cyclic loading within a strain range of 0-15% and a loading frequency range of 0.01-1 Hz. Finally, the CNS/silicone sensor as a wearable device for human motion detection including joint motion, eye blinking, blood pulse and breathing is demonstrated by attaching the sensor to the corresponding parts of the human body. In consideration of the simple fabrication technique, low material cost and excellent strain sensing performance, the CNS/silicone sensor is believed to have great potential in the next-generation of wearable devices for human motion detection.
Lan, Linxin; Niu, Qingfen; Li, Tianduo
2018-09-06
A new simple and efficient oligothiophene-based colorimetric and ratiometric fluorescent probe has been developed for highly sensitive and fast detection of Hg 2+ in water, soil and seafood. The probe 5-(1,3-dithiolan-2-yl)-2,2':5',2″-terthiophene 3 TS can selectively detect Hg 2+ via the Hg 2+ -promoted deprotection reaction of thioacetals, which caused a remarkable color change from colorless to yellow and a strong fluorescence enhancement with emission color varying from blue to yellow, enabling naked-eye detection of Hg 2+ . The probe shows high sensitivity with the detection limit down to 1.03 × 10 -8 M. Visual color changes of 3 TS were observed on filter paper and TLC testing strips when they were impregnated on testing strips and immersed in Hg 2+ solution. Moreover, the probe 3 TS has been successfully used to rapidly detect trace amounts of hazardous Hg 2+ ions in tap, distilled, river and lake water, cropland soil, fish, shrimp and kelp samples with acceptable results and good recoveries. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Tianze; Zhang, Xia; Hou, Luan; Jiang, Chuan
2010-10-01
The characteristics of the beam transmitting in the optical fiber and the liquid medium are analyzed in this paper. On this basis, a new type of semiconductor optical position sensitive detector is used for a receiving device, a light transmission method of birefringence is presented,and a set of opto-electrical detection system which is applied to detect liquid concentration is designed. The system is mainly composed of semiconductor lasers,optical systems, Psd signal conditioning circuit, Single-chip System, A/D conversion circuit and display circuit. Through theoretical analysis and experimental simulations, the accuracy of this system has been verified. Some main factors affecting the test results are analyzed detailedly in this paper. The experiments show that the temperature drift and the light intensity have a very small impact on this system. The system has some advantages, such as the simple structure, high sensitivity, good stability, fast response time, high degree of automation, and so on. It also can achieve the real-time detection of liquid concentration conveniently and accurately. The system can be widely applied in chemical, food, pharmacy and many other industries. It has broad prospects of application.
Nanoparticle assembled microcapsules for application as pH and ammonia sensor.
Amali, Arlin Jose; Awwad, Nour H; Rana, Rohit Kumar; Patra, Digambara
2011-12-05
The encapsulation of molecular probes in a suitable nanostructured matrix can be exploited to alter their optical properties and robustness for fabricating efficient chemical sensors. Despite high sensitivity, simplicity, selectivity and cost effectiveness, the photo-destruction and photo-bleaching are the serious concerns while utilizing molecular probes. Herein we demonstrate that hydroxy pyrene trisulfonate (HPTS), a pH sensitive molecular probe, when encapsulated in a microcapsule structure prepared via the assembly of silica nanoparticles mediated by poly-L-lysine and trisodium citrate, provides a robust sensing material for pH sensing under the physiological conditions. The temporal evolution under continuous irradiation indicates that the fluorophore inside the silica microcapsule is extraordinarily photostable. The fluorescence intensity alternation at dual excitation facilitates for a ratiometic sensing of the pH, however, the fluorescence lifetime is insensitive to hydrogen ion concentration. The sensing scheme is found to be robust, fast and simple for the measurement of pH in the range 5.8-8.0, and can be successfully applied for the determination of ammonia in the concentration range 0-1.2 mM, which is important for aquatic life and the environment. Copyright © 2011 Elsevier B.V. All rights reserved.
Sequeira, Filipa; Duarte, Daniel; Bilro, Lúcia; Rudnitskaya, Alisa; Pesavento, Maria; Zeni, Luigi; Cennamo, Nunzio
2016-12-13
We report the optimization of the length of a D-shaped plastic optical fiber (POF) sensor for refractive index (RI) sensing from a numerical and experimental point of view. The sensing principle is based on total internal reflection (TIR). POFs with 1 mm in diameter were embedded in grooves, realized in planar supports with different lengths, and polished to remove the cladding and part of the core. All D-shaped POF sensors were tested using aqueous medium with different refractive indices (from 1.332 to 1.471) through intensity-based configuration. Results showed two different responses. Considering the refractive index (RI) range (1.33-1.39), the sensitivity and the resolution of the sensor were strongly dependent on the sensing region length. The highest sensitivity (resolution of 6.48 × 10 -3 refractive index units, RIU) was obtained with 6 cm sensing length. In the RI range (1.41-1.47), the length of the sensing region was not a critical aspect to obtain the best resolution. These results enable the application of this optical platform for chemical and biochemical evanescent field sensing. The sensor production procedure is very simple, fast, and low-cost.
Detection of Streptococcus pyogenes using rapid visual molecular assay.
Zhao, Xiangna; He, Xiaoming; Li, Huan; Zhao, Jiangtao; Huang, Simo; Liu, Wei; Wei, Xiao; Ding, Yiwei; Wang, Zhaoyan; Zou, Dayang; Wang, Xuesong; Dong, Derong; Yang, Zhan; Yan, Xiabei; Huang, Liuyu; Du, Shuangkui; Yuan, Jing
2015-09-01
Streptococcus pyogenes is an increasingly important pathogen in many parts of the world. Rapid and accurate detection of S. pyogenes aids in the control of the infection. In this study, a loop-mediated isothermal amplification (LAMP) assay was developed and validated for the specific detection of S. pyogenes. The assay incorporates two methods: a chromogenic analysis using a calcein/Mn(2+) complex and real-time turbidity monitoring to assess the reaction. Both methods detected the target DNA within 60 min under 64°C isothermal conditions. The assay used specifically designed primers to target spy1258, and correctly identified 111 strains of S. pyogenes and 32 non-S. pyogenes strains, including other species of the genus Streptococcus. Tests using reference strains showed that the LAMP assay was highly specific. The sensitivity of the assay, with a detection limit of 1.49 pg DNA, was 10-fold greater than that of PCR. The LAMP assay established in this study is simple, fast and sensitive, and does not rely upon any special equipment; thus, it could be employed in clinical diagnosis. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Su, Lijun; Xiao, Yaoming; Han, Gaoyi; Lin, Jeng-Yu
2018-04-01
Novel feather duster-like nickel sulfide (NiS) @ molybdenum sulfide (MoS2) with hierarchical array structure is synthesized via a simple one-step hydrothermal method, in which a major structure of rod-like NiS in the center and a secondary structure of MoS2 nanosheets with a thickness of about 15-55 nm on the surface. The feather duster-like NiS@MoS2 is employed as the counter electrode (CE) material for the dye-sensitized solar cell (DSSC), which exhibits superior electrocatalytic activity due to its feather duster-like hierarchical array structure can not only support the fast electron transfer and electrolyte diffusion channels, but also can provide high specific surface area (238.19 m2 g-1) with abundant active catalytic sites and large electron injection efficiency from CE to electrolyte. The DSSC based on the NiS@MoS2 CE achieves a competitive photoelectric conversion efficiency of 8.58%, which is higher than that of the NiS (7.13%), MoS2 (7.33%), and Pt (8.16%) CEs under the same conditions. [Figure not available: see fulltext.
Balaguer, Susana; Diaz, Laura; Gomes, Angela; Herrera, Guadalupe; O'Connor, José-Enrique; Urios, Amparo; Felipo, Vicente; Montoliu, Carmina
2017-05-01
Nitric oxide (NO) and its related reactive nitrogen species (RNS) and reactive oxygen species (ROS) are crucial in monocyte responses against pathogens and also in inflammatory conditions. Central to both processes is the generation of the strong oxidant peroxynitrite (ONOO) by a fast reaction between NO and superoxide anion. ONOO is a biochemical junction for ROS- and RNS cytotoxicity and causes protein nitrosylation. Circulating by-products of protein nitrosylation are early biomarkers of inflammation-based conditions, including minimal hepatic encephalopathy in cirrhotic patients (Montoliu et al., Am J Gastroenterol 2011; 106:1629-1637). In this context, we have designed a novel no-wash, no-lyse real-time flow cytometry assay to detect and follow-up the NO- and superoxide-driven generation of ONOO in peripheral blood monocytes. Whole blood samples were stained with CD45 and CD14 antibodies plus one of a series of fluorescent probes sensitive to RNS, ROS, or glutathione, namely 4-amino-5-methylamino-2',7'-difluorofluorescein diacetate, dihydrorhodamine 123, MitoSOX Red, dihydroethidium, and 5-chloromethylfluorescein diacetate. Samples were exposed sequentially to a NO donor and three different superoxide donors, and analyzed in real time by kinetic flow cytometry. Relevant kinetic descriptors, such as the rate of fluorescence change, were calculated from the kinetic plot. The generation of ONOO, which consumes both NO and superoxide, led to a decrease in the intensity of the cellular fluorescence of the probes sensitive to these molecules. This is a fast and simple assay that may be used to monitor the intracellular generation of ONOO in physiological, pathological, and pharmacological contexts. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.
Direct Detection of C_2H_2 in Air and Human Breath by Cw-Crds
NASA Astrophysics Data System (ADS)
Schmidt, Florian M.; Vaittinen, Olavi; Metsälä, Markus; Halonen, Lauri
2010-06-01
Continuous wave cavity ring-down spectroscopy (cw-CRDS) is an established cavity-enhanced absorption technique that can provide the necessary sensitivity, selectivity and fast acquisition time for many applications involving the detection of trace species. We present a simple but highly sensitive cw-CRDS spectrometer based on an external cavity diode laser operating in the near-infrared region. This instrument allows us to directly detect acetylene (C_2H_2) mixing ratios in air with a detection limit of 120 parts per trillion by volume (pptv) measuring on a C_2H_2 absorption line at 6565.620 cm-1. Acetylene is a combustion product that is routinely used in environmental monitoring as a marker for anthropogenic emissions. In a recent work, the spectrometer was employed to measure the level of acetylene in indoor and outdoor air in Helsinki. Continuous flow measurements with high time resolution (one minute) revealed strong fluctuations in the acetylene mixing ratio in outdoor air during daytime. Due to its non-invasive nature and fast response time, the analysis of exhaled breath for medical diagnostics is an excellent and straightforward alternative to methods using urine or blood samples. In an ongoing study, the cw-CRDS instrument is used to establish the baseline level of acetylene in the breath of the healthy population. An elevated amount of acetylene in breath could indicate exposure to combustion exhausts or other volatile organic compound (VOC) rich sources. The latest results of this investigation will be presented. F. M. Schmidt, O. Vaittinen, M. Metsälä, P. Kraus and L. Halonen, submitted for publication in Appl. Phys. B.
Zhao, Lian-Hua; Zhao, Hong-Zheng; Zhao, Xue; Kong, Wei-Jun; Hu, Yi-Chen; Yang, Shi-Hai; Yang, Mei-Hua
2016-05-01
Citri Reticulatae Pericarpium (CRP) is a commonly-used traditional Chinese medicine with flavonoids as the major bioactive components. Nevertheless, the contents of the flavonoids in CRP of different sources may significantly vary affecting their therapeutic effects. Thus, the setting up of a reliable and comprehensive quality assessment method for flavonoids in CRP is necessary. To set up a rapid and sensitive ultra-fast liquid chromatography coupled with tandem mass spectrometry (UFLC-MS/MS) method for simultaneous quantification of seven bioactive flavonoids in CRP. A UFLC-MS/MS method coupled to ultrasound-assisted extraction was developed for simultaneous separation and quantification of seven flavonoids including hesperidin, neohesperidin, naringin, narirutin, tangeretin, nobiletin and sinensetin in 16 batches of CRP samples from different sources in China. The established method showed good linearity for all analytes with correlation coefficient (R) over 0.9980, together with satisfactory accuracy, precision and reproducibility. Furthermore, the recoveries at the three spiked levels were higher than 89.71% with relative standard deviations (RSDs) lower than 5.19%. The results indicated that the contents of seven bioactive flavonoids in CRP varied significantly among different sources. Among the samples under study, hesperidin showed the highest contents in 16 samples ranged from 27.50 to 86.30 mg/g, the contents of hesperidin in CRP-15 and CRP-9 were 27.50 and 86.30 mg/g, respectively, while, the amount of narirutin was too low to be measured in some samples. This study revealed that the developed UFLC-MS/MS method was simple, sensitive and reliable for simultaneous quantification of multi-components in CRP with potential perspective for quality control of complex matrices. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Yang, Xuemei; Li, Guoliang; Chen, Lingyun; Zhang, Cong; Wan, Xinxiang; Xu, Jiangping
2011-07-01
A rapid, sensitive and selective method was developed for the quantitative determination of hederagenin in rat plasma and cerebrospinal fluid (CSF) by ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS). It has been successfully applied in a pharmacokinetic study of hederagenin in the central nervous system (CNS). Sample pretreatment involved a simple protein precipitation with methanol and a one-step extraction with ethyl acetate. Separation was carried out in a Shim-pack XR-ODS II (75 mm × 2.0 mm, i.d., 2.1 μm) column with gradient elution at a flow rate of 0.35 mL/min. The mobile phase was 5mM ammonium acetate and acetonitrile. Detection was performed in a triple-quadruple tandem mass spectrometer by multiple-reaction-monitoring mode via electrospray ionization. A linear calibration curve for hederagenin was obtained over a concentration range of 0.406 (lower limit of quantification, LLOQ) to 203 ng/mL (r² > 0.99) for both plasma and CSF. The intra-day and inter-day precision (relative standard deviation, RSD) values were less than 15%. At all quality control (QC) levels, the accuracy (relative error, RE) was within -9.0% and 11.1% for plasma and CSF, respectively. The pharmacokinetics results indicated that hederagenin could pass through the blood-brain barrier. This UFLC-MS/MS method demonstrates higher sensitivity and sample throughput than previous methods. It was also successfully applied to the pharmacokinetic study of hederagenin following oral administration of Fructus akebiae extract in rats. Copyright © 2011 Elsevier B.V. All rights reserved.
Zhang, Guojun; Zheng, Guanghui; Zhang, Yan; Ma, Ruimin; Kang, Xixiong
2018-05-01
Post-neurosurgical meningitis (PNM) is one of the most severe hospital-acquired infections worldwide, and a large number of pathogens, especially those possessing multi-resistance genes, are related to these infections. Existing methods for detecting bacteria and measuring their response to antibiotics lack sensitivity and stability, and laboratory-based detection methods are inconvenient, requiring at least 24h to complete. Rapid identification of bacteria and the determination of their susceptibility to antibiotics are urgently needed, in order to combat the emergence of multi-resistant bacterial strains. This study evaluated a novel, fast, and easy-to-use micro/nanofluidic chip platform (MNCP), which overcomes the difficulties of diagnosing bacterial infections in neurosurgery. This platform can identify 10 genus or species targets and 13 genetic resistance determinants within 1h, and it is very simple to operate. A total of 108 bacterium-containing cerebrospinal fluid (CSF) cultures were tested using the MNCP for the identification of bacteria and determinants of genetic resistance. The results were compared to those obtained with conventional identification and antimicrobial susceptibility testing methods. For the 108 CSF cultures, the concordance rate between the MNCP and the conventional identification method was 94.44%; six species attained 100% consistency. For the production of carbapenemase- and extended-spectrum beta-lactamase (ESBL)-related antibiotic resistance genes, both the sensitivity and specificity of the MNCP tests were high (>90.0%) and could fully meet the requirements of clinical diagnosis. The MNCP is fast, accurate, and easy to use, and has great clinical potential in the treatment of post-neurosurgical meningitis. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
ERIC Educational Resources Information Center
Digilov, Rafael M.
2008-01-01
We describe a simple and very inexpensive undergraduate laboratory experiment for fast determination of Young's modulus at moderate temperatures with the aid of a force sensor. A strip-shaped specimen rigidly bolted to the force sensor forms a clamped-free cantilever beam. Placed in a furnace, it is subjected to free-bending vibrations followed by…
ERIC Educational Resources Information Center
Vollmer, Michael; Mollmann, Klaus-Peter
2012-01-01
The recent introduction of inexpensive high-speed cameras offers a new experimental approach to many simple but fast-occurring events in physics. In this paper, the authors present two simple demonstration experiments recorded with high-speed cameras in the fields of gas dynamics and thermal physics. The experiments feature vapour pressure effects…
Ueda, Keijiro; Kawabe, Ken; Lee, Lingaku; Tachibana, Yuichi; Fujimori, Nao; Igarashi, Hisato; Oda, Yoshinao; Jensen, Robert T; Takayanagi, Ryoichi; Ito, Tetsuhide
2017-04-01
This study aimed to evaluate the usefulness of the 48-hour fasting test and insulin surrogates followed by a glucagon stimulatory test (GST) for the diagnosis of insulinoma. Thirty-five patients with suspected insulinoma who underwent 48-hour fasting test and GST were retrospectively included in our study: 15 patients with surgically proven insulinomas and 20 patients in whom insulinoma was clinically ruled out. We determined the duration of the fasting test, plasma glucose levels, serum levels of immunoreactive insulin and C-peptide, and insulin surrogates (serum levels of β-hydroxybutyrate, free fatty acid, and response of plasma glucose to intravenous glucagon [ΔPG]) at the end of the fast. The sensitivity and specificity of the 48-hour fasting test were 100.0% and 80.0%, respectively, for the diagnosis of insulinoma. When the 48-hour fasting test and immunoreactive insulin, C-peptide, or insulin surrogates were combined, the combination with GST showed the best results. The sensitivity, specificity, and accuracy rate were 93.3%, 95.0%, and 94.3%, respectively, with 1 false-negative case and 1 false-positive case occurring. A more accurate and less invasive diagnosis of insulinoma was possible by combining the 48-hour fasting test with the GST, compared with the existing method.
2018-01-01
This contribution describes a simple, fast, and sensitive application of localized surface plasmon resonance effect of silver nanoparticles for simultaneous determination of antihypertensive drugs' mixture atenolol and amiloride in both pharmaceutical dosage forms and in biological samples (urine). Silver nanoparticles were prepared by chemical reduction of silver nitrate using hydroxylamine HCL in an alkaline medium. Application of silver-hydroxylamine nanoparticles (SH NPs) provides many advantages including reproducibility, sensitivity, and cost effective way of analyte determination. Amiloride has four amino groups which act as attachment points on the surface of silver nanoparticles resulting in a synergistic effect on the absorption intensity of atenolol, leading to increase the sensitivity of the determination of both compounds. This method shows excellent advantages comparing with the previously reported methods, including accuracy, precision, and selectivity. The linear range of atenolol is 1 × 10−5–1 × 10−4 mol·L−1 and of amiloride is 1 × 10−6–1 × 10−5 mol·L−1. The limit of detection (LOD) values of atenolol and amiloride are 0.89 × 10−5 and 0.42 × 10−6 mol·L−1, respectively. PMID:29576886
A practical toxicity bioassay for vicine and convicine levels in faba bean (Vicia faba).
Getachew, Fitsum; Vandenberg, Albert; Smits, Judit
2018-04-02
Faba bean (Vicia faba) vicine and convicine (V-C) aglycones (divicine and isouramil respectively) provoke an acute hemolytic anemia called favism in individuals with a glucose-6-phosphate dehydrogenase (G6PD) enzyme defect in their red blood cells. Geneticists/plant breeders are working with faba bean to decrease V-C levels to improve public acceptance of this high-protein pulse crop. Here, we present a fast and simple ex vivo in vitro bioassay for V-C toxicity testing of faba bean or faba bean food products. We have shown that 1,3-bis (2-chloroethyl)-1-nitrosourea (BCNU)-treated (i.e., sensitized) normal red blood cells, like G6PD-defective blood, displayed (i) continuous glutathione (GSH) depletion with no regeneration as incubation time and the dose of aglycones increased, (ii) progressive accumulation of denatured hemoglobin products into high molecular weight (HMW) proteins with increased aglycone dose, (iii) both band 3 membrane proteins and hemichromes, in HMW protein aggregates. We have also demonstrated that sensitized red blood cells can effectively differentiate various levels of toxicity among faba bean varieties through the two hemolysis biomarkers: GSH depletion and HMW clumping. BCNU-sensitized red blood cells provide an ideal model for favism blood, to assess and compare the toxicity of faba bean varieties and their food products. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
Wang, Yingcheng; Jin, Yuanhao; Xiao, Xiaoyang; Zhang, Tianfu; Yang, Haitao; Zhao, Yudan; Wang, Jiaping; Jiang, Kaili; Fan, Shoushan; Li, Qunqing
2018-05-30
A flexible and transparent film assembled from the cross-nanoporous structures of Au on PET (CNS of Au@PET) is developed as a versatile and effective SERS substrate for rapid, on-site trace analysis with high sensitivity. The fabrication of the CNS of Au can be achieved on a large scale at low cost by employing an etching process with super-aligned carbon nanotubes as a mask, followed by metal deposition. A strongly enhanced Raman signal with good uniformity can be obtained, which is attributed to the excitation of "hot spots" around the metal nanogaps and sharp edges. Using the CNS of Au@PET film as a SERS platform, real-time and on-site SERS detection of the food contaminant crystal violet (CV) is achieved, with a detection limit of CV solution on a tomato skin of 10-7 M. Owing to its ability to efficiently extract trace analytes, the resulting substrate also achieves detection of 4-ATP contaminants and thiram pesticides by swabbing the skin of an apple. A SERS detection signal for 4-ATP has a relative standard deviation of less than 10%, revealing the excellent reproducibility of the substrate. The flexible, transparent and highly sensitive substrates fabricated using this simple and cost-effective strategy are promising for practical application in rapid, on-site SERS-based detection.
Evaluation of the accuracy of the EasyTest™ malaria Pf/Pan Ag, a rapid diagnostic test, in Uganda.
Chong, Chom-Kyu; Cho, Pyo Yun; Na, Byoung-Kuk; Ahn, Seong Kyu; Kim, Jin Su; Lee, Jin-Soo; Lee, Sung-Keun; Han, Eun-Taek; Kim, Hak-Yong; Park, Yun-Kyu; Cha, Seok Ho; Kim, Tong-Soo
2014-10-01
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.
Evaluation of the Accuracy of the EasyTest™ Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in Uganda
Chong, Chom-Kyu; Cho, Pyo Yun; Na, Byoung-Kuk; Ahn, Seong Kyu; Kim, Jin Su; Lee, Jin-Soo; Lee, Sung-Keun; Han, Eun-Taek; Kim, Hak-Yong; Park, Yun-Kyu; Cha, Seok Ho
2014-01-01
In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda. PMID:25352698
NASA Astrophysics Data System (ADS)
Khodabakhsh, Amir; Johansson, Alexandra C.; Foltynowicz, Aleksandra
2015-04-01
Noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS) is a recently developed technique that utilizes phase modulation to obtain immunity to frequency-to-amplitude noise conversion by the cavity modes and yields high absorption sensitivity over a broad spectral range. We describe the principles of the technique and discuss possible comb-cavity matching solutions. We present a theoretical description of NICE-OFCS signals detected with a Fourier transform spectrometer (FTS) and validate the model by comparing it to experimental CO2 spectra around 1,575 nm. Our system is based on an Er:fiber femtosecond laser locked to a cavity and phase-modulated at a frequency equal to a multiple of the cavity free spectral range (FSR). The NICE-OFCS signal is detected by a fast-scanning FTS equipped with a high-bandwidth commercial detector. We demonstrate a simple method of passive locking of the modulation frequency to the cavity FSR that significantly improves the long-term stability of the system, allowing averaging times on the order of minutes. Using a cavity with a finesse of ~9,000, we obtain absorption sensitivity of 6.4 × 10-11 cm-1 Hz-1/2 per spectral element and concentration detection limit for CO2 of 450 ppb Hz-1/2, determined by multiline fitting.
Effect of insulin sensitizer therapy on amino acids and their metabolites.
Irving, Brian A; Carter, Rickey E; Soop, Mattias; Weymiller, Audrey; Syed, Husnain; Karakelides, Helen; Bhagra, Sumit; Short, Kevin R; Tatpati, Laura; Barazzoni, Rocco; Nair, K Sreekumaran
2015-06-01
Prior studies have reported that elevated concentrations of several plasma amino acids (AA), particularly branched chain (BCAA) and aromatic AA predict the onset of type 2 diabetes. We sought to test the hypothesis that circulating BCAA, aromatic AA and related AA metabolites decline in response to the use of insulin sensitizing agents in overweight/obese adults with impaired fasting glucose or untreated diabetes. We performed a secondary analysis of a randomized, double-blind, placebo, controlled study conducted in twenty five overweight/obese (BMI ~30kg/m(2)) adults with impaired fasting glucose or untreated diabetes. Participants were randomized to three months of pioglitazone (45mg per day) plus metformin (1000mg twice per day, N=12 participants) or placebo (N=13). We measured insulin sensitivity by the euglycemic-hyperinsulinemic clamp and fasting concentrations of AA and AA metabolites using ultra-pressure liquid chromatography tandem mass spectrometry before and after the three-month intervention. Insulin sensitizer therapy that significantly enhanced insulin sensitivity reduced 9 out of 33 AA and AA metabolites measured compared to placebo treatment. Moreover, insulin sensitizer therapy significantly reduced three functionally clustered AA and metabolite pairs: i) phenylalanine/tyrosine, ii) citrulline/arginine, and iii) lysine/α-aminoadipic acid. Reductions in plasma concentrations of several AA and AA metabolites in response to three months of insulin sensitizer therapy support the concept that reduced insulin sensitivity alters AA and AA metabolites. Copyright © 2015 Elsevier Inc. All rights reserved.
In Silico PCR Tools for a Fast Primer, Probe, and Advanced Searching.
Kalendar, Ruslan; Muterko, Alexandr; Shamekova, Malika; Zhambakin, Kabyl
2017-01-01
The polymerase chain reaction (PCR) is fundamental to molecular biology and is the most important practical molecular technique for the research laboratory. The principle of this technique has been further used and applied in plenty of other simple or complex nucleic acid amplification technologies (NAAT). In parallel to laboratory "wet bench" experiments for nucleic acid amplification technologies, in silico or virtual (bioinformatics) approaches have been developed, among which in silico PCR analysis. In silico NAAT analysis is a useful and efficient complementary method to ensure the specificity of primers or probes for an extensive range of PCR applications from homology gene discovery, molecular diagnosis, DNA fingerprinting, and repeat searching. Predicting sensitivity and specificity of primers and probes requires a search to determine whether they match a database with an optimal number of mismatches, similarity, and stability. In the development of in silico bioinformatics tools for nucleic acid amplification technologies, the prospects for the development of new NAAT or similar approaches should be taken into account, including forward-looking and comprehensive analysis that is not limited to only one PCR technique variant. The software FastPCR and the online Java web tool are integrated tools for in silico PCR of linear and circular DNA, multiple primer or probe searches in large or small databases and for advanced search. These tools are suitable for processing of batch files that are essential for automation when working with large amounts of data. The FastPCR software is available for download at http://primerdigital.com/fastpcr.html and the online Java version at http://primerdigital.com/tools/pcr.html .
Agrawal, Abhay V; Kumar, Rahul; Venkatesan, Swaminathan; Zakhidov, Alex; Yang, Guang; Bao, Jiming; Kumar, Mahesh; Kumar, Mukesh
2018-05-25
Toxic gases are produced during the burning of fossil fuels. Room temperature (RT) fast detection of toxic gases is still challenging. Recently, MoS 2 transition metal dichalcogenides have sparked great attention in the research community due to their performance in gas sensing applications. However, MoS 2 based gas sensors still suffer from long response and recovery times, especially at RT. Considering this challenge, here, we report photoactivated highly reversible and fast detection of NO 2 sensors at room temperature (RT) by using mixed in-plane and edge-enriched p-MoS 2 flakes (mixed MoS 2 ). The sensor showed fast response with good sensitivity of ∼10.36% for 10 ppm of NO 2 at RT without complete recovery. However, complete recovery was obtained with better sensor performance under UV light illumination at RT. The UV assisted NO 2 sensing showed improved performance in terms of fast response and recovery kinetics with enhanced sensitivity to 10 ppm NO 2 concentration. The sensor performance is also investigated under thermal energy, and a better sensor performance with reduced sensitivity and high selectivity toward NO 2 was observed. A detailed gas sensing mechanism based on the density functional theory (DFT) calculations for favorable NO 2 adsorption sites on in-plane and edge-enriched MoS 2 flakes is proposed. This study revealed the role of favorable adsorption sites in MoS 2 flakes for the enhanced interaction of target gases and developed a highly sensitive, reversible, and fast gas sensor for next-generation toxic gases at room temperature.
Bermudez, Beatriz; Ortega-Gomez, Almudena; Varela, Lourdes M; Villar, Jose; Abia, Rocio; Muriana, Francisco J G; Lopez, Sergio
2014-07-25
Dietary fatty acids play a role in glucose homeostasis. The aim of this study was to assess the individual relationship between dietary saturated (SFA), monounsaturated (MUFA) and polyunsaturated (PUFA) fatty acids with postprandial β-cell function and insulin sensitivity in subjects with normal and high fasting triglycerides. We assessed postprandial β-cell function (by the insulinogenic index and the ratio of the insulin to glucose areas under the time-concentration curve) and insulin sensitivity (by the oral glucose and the minimal model insulin sensitivity indices) over four nonconsecutive, randomly assigned, high-fat meals containing a panel of SFA (palmitic and stearic acids), MUFA (palmitoleic and oleic acids) and PUFA (linoleic and α-linolenic acids) in 14 subjects with normal and in 14 subjects with high fasting triglycerides. The proportions of each fatty acid in the meals and the values for surrogate measures of postprandial β-cell function and insulin sensitivity were subjected to a Pearson correlation and hierarchical cluster analysis, which revealed two classes of dietary fatty acids for regulating postprandial glucose homeostasis. We successfully discriminated the adverse effects of SFA palmitic acid from the beneficial effects of MUFA oleic acid on postprandial β-cell function (r ≥ 0.84 for SFA palmitic acid and r ≥ -0.71 for MUFA oleic acid; P < 0.05) and insulin sensitivity (r ≥ -0.92 for SFA palmitic acid and r ≥ 0.89 for MUFA oleic acid; P < 0.001) both in subjects with normal and high fasting triglycerides. In conclusion, dietary MUFA oleic acid, in contrast to SFA palmitic acid, favours the tuning towards better postprandial glycaemic control in subjects with normal and high fasting triglycerides.
Time-dependent climate sensitivity and the legacy of anthropogenic greenhouse gas emissions
Zeebe, Richard E.
2013-01-01
Climate sensitivity measures the response of Earth’s surface temperature to changes in forcing. The response depends on various climate processes that feed back on the initial forcing on different timescales. Understanding climate sensitivity is fundamental to reconstructing Earth’s climatic history as well as predicting future climate change. On timescales shorter than centuries, only fast climate feedbacks including water vapor, lapse rate, clouds, and snow/sea ice albedo are usually considered. However, on timescales longer than millennia, the generally higher Earth system sensitivity becomes relevant, including changes in ice sheets, vegetation, ocean circulation, biogeochemical cycling, etc. Here, I introduce the time-dependent climate sensitivity, which unifies fast-feedback and Earth system sensitivity. I show that warming projections, which include a time-dependent climate sensitivity, exhibit an enhanced feedback between surface warming and ocean CO2 solubility, which in turn leads to higher atmospheric CO2 levels and further warming. Compared with earlier studies, my results predict a much longer lifetime of human-induced future warming (23,000–165,000 y), which increases the likelihood of large ice sheet melting and major sea level rise. The main point regarding the legacy of anthropogenic greenhouse gas emissions is that, even if the fast-feedback sensitivity is no more than 3 K per CO2 doubling, there will likely be additional long-term warming from slow climate feedbacks. Time-dependent climate sensitivity also helps explaining intense and prolonged warming in response to massive carbon release as documented for past events such as the Paleocene–Eocene Thermal Maximum. PMID:23918402
Time-dependent climate sensitivity and the legacy of anthropogenic greenhouse gas emissions.
Zeebe, Richard E
2013-08-20
Climate sensitivity measures the response of Earth's surface temperature to changes in forcing. The response depends on various climate processes that feed back on the initial forcing on different timescales. Understanding climate sensitivity is fundamental to reconstructing Earth's climatic history as well as predicting future climate change. On timescales shorter than centuries, only fast climate feedbacks including water vapor, lapse rate, clouds, and snow/sea ice albedo are usually considered. However, on timescales longer than millennia, the generally higher Earth system sensitivity becomes relevant, including changes in ice sheets, vegetation, ocean circulation, biogeochemical cycling, etc. Here, I introduce the time-dependent climate sensitivity, which unifies fast-feedback and Earth system sensitivity. I show that warming projections, which include a time-dependent climate sensitivity, exhibit an enhanced feedback between surface warming and ocean CO2 solubility, which in turn leads to higher atmospheric CO2 levels and further warming. Compared with earlier studies, my results predict a much longer lifetime of human-induced future warming (23,000-165,000 y), which increases the likelihood of large ice sheet melting and major sea level rise. The main point regarding the legacy of anthropogenic greenhouse gas emissions is that, even if the fast-feedback sensitivity is no more than 3 K per CO2 doubling, there will likely be additional long-term warming from slow climate feedbacks. Time-dependent climate sensitivity also helps explaining intense and prolonged warming in response to massive carbon release as documented for past events such as the Paleocene-Eocene Thermal Maximum.
Mokhtari, Amirhossein; Christopher Frey, H; Zheng, Junyu
2006-11-01
Sensitivity analyses of exposure or risk models can help identify the most significant factors to aid in risk management or to prioritize additional research to reduce uncertainty in the estimates. However, sensitivity analysis is challenged by non-linearity, interactions between inputs, and multiple days or time scales. Selected sensitivity analysis methods are evaluated with respect to their applicability to human exposure models with such features using a testbed. The testbed is a simplified version of a US Environmental Protection Agency's Stochastic Human Exposure and Dose Simulation (SHEDS) model. The methods evaluated include the Pearson and Spearman correlation, sample and rank regression, analysis of variance, Fourier amplitude sensitivity test (FAST), and Sobol's method. The first five methods are known as "sampling-based" techniques, wheras the latter two methods are known as "variance-based" techniques. The main objective of the test cases was to identify the main and total contributions of individual inputs to the output variance. Sobol's method and FAST directly quantified these measures of sensitivity. Results show that sensitivity of an input typically changed when evaluated under different time scales (e.g., daily versus monthly). All methods provided similar insights regarding less important inputs; however, Sobol's method and FAST provided more robust insights with respect to sensitivity of important inputs compared to the sampling-based techniques. Thus, the sampling-based methods can be used in a screening step to identify unimportant inputs, followed by application of more computationally intensive refined methods to a smaller set of inputs. The implications of time variation in sensitivity results for risk management are briefly discussed.
Perseghin, G; Caumo, A; Lattuada, G; De Cobelli, F; Ntali, G; Esposito, A; Belloni, E; Canu, T; Ragogna, F; Scifo, P; Del Maschio, A; Luzi, L
2009-09-01
Studies have pointed to insulin resistance as a pathogenic factor in fatty liver. Although pancreatic B-cell function is believed to be involved, its role is unclear. This study was undertaken to test whether fasting C-peptide, an index of fasting B-cell function, was related to intra-hepatic fat (IHF) content in non-diabetic humans. We assessed, retrospectively, fasting plasma C-peptide concentration in 31 patients with fatty liver and 62 individuals without fatty liver. The IHF content was measured by proton magnetic resonance spectroscopy ((1)H-MRS), while insulin sensitivity was estimated based on fasting plasma glucose and insulin with the homestasis model assessment (HOMA) 2 method. Age, sex and body mass index (BMI) were not different between groups. Patients with fatty liver had higher fasting insulin (P < 0.01), C-peptide (P < 0.005) and lower insulin sensitivity (HOMA2-%S). Fasting insulin alone explained 14% of the IHF content variability (P < 0.001); inclusion of fasting C-peptide in multivariate regression explained up to 32% (P < 0.001). A subgroup analysis was performed by matching 1 : 1 for HOMA2-%S. These data were analysed by conditional logistic regression which showed that, when HOMA2-%S was matched between groups, fasting C-peptide remained the only significant predictor of fatty liver. Non-diabetic individuals with fatty liver are characterized by increased fasting plasma C-peptide concentration, irrespective of their insulin resistant state.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, T.; Jensen, R.; Christensen, M. K.
2012-07-15
We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/{Delta}m > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detectionmore » by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH{sub 3}.« less
NASA Astrophysics Data System (ADS)
Andersen, T.; Jensen, R.; Christensen, M. K.; Pedersen, T.; Hansen, O.; Chorkendorff, I.
2012-07-01
We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/Δm > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH3.
Andersen, T; Jensen, R; Christensen, M K; Pedersen, T; Hansen, O; Chorkendorff, I
2012-07-01
We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/Δm > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH(3).
A simple and fast representation space for classifying complex time series
NASA Astrophysics Data System (ADS)
Zunino, Luciano; Olivares, Felipe; Bariviera, Aurelio F.; Rosso, Osvaldo A.
2017-03-01
In the context of time series analysis considerable effort has been directed towards the implementation of efficient discriminating statistical quantifiers. Very recently, a simple and fast representation space has been introduced, namely the number of turning points versus the Abbe value. It is able to separate time series from stationary and non-stationary processes with long-range dependences. In this work we show that this bidimensional approach is useful for distinguishing complex time series: different sets of financial and physiological data are efficiently discriminated. Additionally, a multiscale generalization that takes into account the multiple time scales often involved in complex systems has been also proposed. This multiscale analysis is essential to reach a higher discriminative power between physiological time series in health and disease.
A fast and simple bonding method for low cost microfluidic chip fabrication
NASA Astrophysics Data System (ADS)
Yin, Zhifu; Zou, Helin
2018-01-01
With the development of the microstructure fabrication technique, microfluidic chips are widely used in biological and medical researchers. Future advances in their commercial applications depend on the mass bonding of microfluidic chip. In this study we are presenting a simple, low cost and fast way of bonding microfluidic chips at room temperature. The influence of the bonding pressure on the deformation of the microchannel and adhesive tape was analyzed by numerical simulation. By this method, the microfluidic chip can be fully sealed at low temperature and pressure without using any equipment. The dye water and gas leakage test indicated that the microfluidic chip can be bonded without leakage or block and its bonding strength can up to 0.84 MPa.
NASA Technical Reports Server (NTRS)
Kershaw, David S.; Prasad, Manoj K.; Beason, J. Douglas
1986-01-01
The Klein-Nishina differential cross section averaged over a relativistic Maxwellian electron distribution is analytically reduced to a single integral, which can then be rapidly evaluated in a variety of ways. A particularly fast method for numerically computing this single integral is presented. This is, to the authors' knowledge, the first correct computation of the Compton scattering kernel.
NASA Astrophysics Data System (ADS)
Poggialini, F.; Campanella, B.; Giannarelli, S.; Grifoni, E.; Legnaioli, S.; Lorenzetti, G.; Pagnotta, S.; Safi, A.; Palleschi, V.
2018-03-01
When compared to other analytical techniques, LIBS shows relatively low precision and, generally, high Limits of Detection (LODs). Until recently, the attempts in improving the LIBS performances have been based on the use of more stable/powerful lasers, high sensitivity detectors or controlled environmental parameters. This can hinder the competitiveness of LIBS by increasing the instrumental setup cost and the difficulty of operation. Sample treatment has proved to be a viable and simple way to increase the LIBS signal; in particular, the Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) methodology uses a deposition of metal nanoparticles on the sample to greatly increase the emission of the LIBS plasma. In this work, we used a simple, fast, "green" and low-cost method to synthetize silver nanoparticles by using coffee extract as reducing agents for a silver nitrate solution. This allowed us to obtain nanoparticles of about 25 nm in diameter. We then explored the application of such nanoparticles to the NELIBS analysis of metallic samples with a mobile LIBS instrument. By adjusting the laser parameters and optimizing the sample preparation procedure, we obtained a NELIBS signal that is 4 times the LIBS one. This showed the potential of green-synthetized nanoparticle for NELIBS applications and suggests the possibility of an in-situ application of the technique.
Foust, Amanda; Popovic, Marko; Zecevic, Dejan; McCormick, David A.
2010-01-01
Purkinje neurons are the output cells of the cerebellar cortex and generate spikes in two distinct modes, known as simple and complex spikes. Revealing the point of origin of these action potentials, and how they conduct into local axon collaterals, is important for understanding local and distal neuronal processing and communication. By utilizing a recent improvement in voltage sensitive dye imaging technique that provided exceptional spatial and temporal resolution, we were able to resolve the region of spike initiation as well as follow spike propagation into axon collaterals for each action potential initiated on single trials. All fast action potentials, for both simple and complex spikes, whether occurring spontaneously or in response to a somatic current pulse or synaptic input, initiated in the axon initial segment. At discharge frequencies of less than approximately 250 Hz, spikes propagated faithfully through the axon and axon collaterals, in a saltatory manner. Propagation failures were only observed for very high frequencies or for the spikelets associated with complex spikes. These results demonstrate that the axon initial segment is a critical decision point in Purkinje cell processing and that the properties of axon branch points are adjusted to maintain faithful transmission. PMID:20484631
Soponar, Florin; Moţ, Augustin C; Sârbu, Costel
2010-01-01
A novel HPTLC method was developed for fast and simple quantitative determination of rutin in pharmaceutical preparations. The proposed method combines the advantages of HPTLC with the comfort and the convenience of digital processing of images. For the separation of rutin, silica gel with attached amino groups was used as the stationary phase and ethyl acetate-formic acid-methanol-water (10 + 0.9 + 1.1 + 1.7, v/v/v/v) as the mobile phase. The chromatographic plate was sprayed with 2-aminoethyldiphenyl borate solution for visual detection of the spots. For the construction of a three-dimensional chromatogram, Melanie 7.0 software was used together with an HP flatbed scanner that allowed capture of the images on chromatographic plates. The calibration curve was linear within the range of 0.95-4.78 microg/spot with an r value of 0.9984. The RSD for six replicates at three concentration levels was less than 3%, while the recovery was between 97.28 and 103.27%. The proposed method was found to be simple, precise, sensitive, and accurate and has been applied for the determination of rutin in two commercial drugs. The results were compared with the results of other techniques that generate bidimensional chromatograms and validated by UV-Vis spectrophotometry.
A novel method for fast imaging of brain function, non-invasively, with light
NASA Astrophysics Data System (ADS)
Chance, Britton; Anday, Endla; Nioka, Shoko; Zhou, Shuoming; Hong, Long; Worden, Katherine; Li, C.; Murray, T.; Ovetsky, Y.; Pidikiti, D.; Thomas, R.
1998-05-01
Imaging of the human body by any non-invasive technique has been an appropriate goal of physics and medicine, and great success has been obtained with both Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) in brain imaging. Non-imaging responses to functional activation using near infrared spectroscopy of brain (fNIR) obtained in 1993 (Chance, et al. [1]) and in 1994 (Tamura, et al. [2]) are now complemented with images of pre-frontal and parietal stimulation in adults and pre-term neonates in this communication (see also [3]). Prior studies used continuous [4], pulsed [3] or modulated [5] light. The amplitude and phase cancellation of optical patterns as demonstrated for single source detector pairs affords remarkable sensitivity of small object detection in model systems [6]. The methods have now been elaborated with multiple source detector combinations (nine sources, four detectors). Using simple back projection algorithms it is now possible to image sensorimotor and cognitive activation of adult and pre- and full-term neonate human brain function in times < 30 sec and with two dimensional resolutions of < 1 cm in two dimensional displays. The method can be used in evaluation of adult and neonatal cerebral dysfunction in a simple, portable and affordable method that does not require immobilization, as contrasted to MRI and PET.
A study on gaseous extinguishing agent sensing with a simple measurement method
NASA Astrophysics Data System (ADS)
Guan, Yu; Lu, Song; Yuan, Wei; Qian, Hanjie
2018-03-01
As research on the concentration distribution for evaluating the effectiveness of a gas fire extinguisher system is quite important, the proper sensing technology is necessary. Here, a simple method used for measuring the concentration of agent is introduced, and the manufacture of the sensing part is described clearly. The sensing unit is composed of a pressure reducing structure and pressure sensor element. The detection was achieved by sensing the change of pressure difference caused by gas flow. In order to verify the theory and characterize the sensing performance, two types of fire extinguishing agents, bromotrifluoromethane (CBrF3) and heptafluoropropane (C3HF7), were used in the experiments. The results showed a high sensitivity from 0 to 100%, good repeatability and fast response/recovery time. Furthermore, the effect of operating temperature, humidity and geometric structure on the response were investigated. Measurements showed, for CBrF3, that the temperature had a linear impact on the response and the influence of humidity in the sensor was negligible. Through the analysis of the geometry parameter, it was found that the sensing performance could be greatly improved through adjusting the geometry structure. This technique provides a low-cost and highly reliable sensor for the detection of gaseous extinguishing agent that can be easily fabricated.
NASA Astrophysics Data System (ADS)
Steinberg, Idan; Harbater, Osnat; Gannot, Israel
2014-07-01
The diffusion approximation is useful for many optical diagnostics modalities, such as near-infrared spectroscopy. However, the simple normal incidence, semi-infinite layer model may prove lacking in estimation of deep-tissue optical properties such as required for monitoring cerebral hemodynamics, especially in neonates. To answer this need, we present an analytical multilayered, oblique incidence diffusion model. Initially, the model equations are derived in vector-matrix form to facilitate fast and simple computation. Then, the spatiotemporal reflectance predicted by the model for a complex neonate head is compared with time-resolved Monte Carlo (TRMC) simulations under a wide range of physiologically feasible parameters. The high accuracy of the multilayer model is demonstrated in that the deviation from TRMC simulations is only a few percent even under the toughest conditions. We then turn to solve the inverse problem and estimate the oxygen saturation of deep brain tissues based on the temporal and spatial behaviors of the reflectance. Results indicate that temporal features of the reflectance are more sensitive to deep-layer optical parameters. The accuracy of estimation is shown to be more accurate and robust than the commonly used single-layer diffusion model. Finally, the limitations of such approaches are discussed thoroughly.
Secure web-based access to radiology: forms and databases for fast queries
NASA Astrophysics Data System (ADS)
McColl, Roderick W.; Lane, Thomas J.
2002-05-01
Currently, Web-based access to mini-PACS or similar databases commonly utilizes either JavaScript, Java applets or ActiveX controls. Many sites do not permit applets or controls or other binary objects for fear of viruses or worms sent by malicious users. In addition, the typical CGI query mechanism requires several parameters to be sent with the http GET/POST request, which may identify the patient in some way; this in unacceptable for privacy protection. Also unacceptable are pages produced by server-side scripts which can be cached by the browser, since these may also contain sensitive information. We propose a simple mechanism for access to patient information, including images, which guarantees security of information, makes it impossible to bookmark the page, or to return to the page after some defined length of time. In addition, this mechanism is simple, therefore permitting rapid access without the need to initially download an interface such as an applet or control. In addition to image display, the design of the site allows the user to view and save movies of multi-phasic data, or to construct multi-frame datasets from entire series. These capabilities make the site attractive for research purposes such as teaching file preparation.
FAITH – Fast Assembly Inhibitor Test for HIV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague
Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less
Good cash flow = come in fast, go out slow!
Garvey, Sherill
2002-07-01
The formula for successful cash management in home care is a simple one: The agency must bring cash in as quickly as possible, while keeping expenditures at as low and slow a pace as possible. However, while the formula may be simple, success may be elusive unless agency administrators have a well-thought-out plan to handle cash management.
Architectural-level power estimation and experimentation
NASA Astrophysics Data System (ADS)
Ye, Wu
With the emergence of a plethora of embedded and portable applications and ever increasing integration levels, power dissipation of integrated circuits has moved to the forefront as a design constraint. Recent years have also seen a significant trend towards designs starting at the architectural (or RT) level. Those demand accurate yet fast RT level power estimation methodologies and tools. This thesis addresses issues and experiments associate with architectural level power estimation. An execution driven, cycle-accurate RT level power simulator, SimplePower, was developed using transition-sensitive energy models. It is based on the architecture of a five-stage pipelined RISC datapath for both 0.35mum and 0.8mum technology and can execute the integer subset of the instruction set of SimpleScalar . SimplePower measures the energy consumed in the datapath, memory and on-chip buses. During the development of SimplePower , a partitioning power modeling technique was proposed to model the energy consumed in complex functional units. The accuracy of this technique was validated with HSPICE simulation results for a register file and a shifter. A novel, selectively gated pipeline register optimization technique was proposed to reduce the datapath energy consumption. It uses the decoded control signals to selectively gate the data fields of the pipeline registers. Simulation results show that this technique can reduce the datapath energy consumption by 18--36% for a set of benchmarks. A low-level back-end compiler optimization, register relabeling, was applied to reduce the on-chip instruction cache data bus switch activities. Its impact was evaluated by SimplePower. Results show that it can reduce the energy consumed in the instruction data buses by 3.55--16.90%. A quantitative evaluation was conducted for the impact of six state-of-art high-level compilation techniques on both datapath and memory energy consumption. The experimental results provide a valuable insight for designers to develop future power-aware compilation frameworks for embedded systems.
Radiocarbon Evidence That Millennial and Fast-Cycling Soil Carbon are Equally Sensitive to Warming
NASA Astrophysics Data System (ADS)
Vaughn, L. S.; Torn, M. S.; Porras, R. C.
2017-12-01
Within the century, the Arctic is expected to shift from a sink to a source of atmospheric CO2 due to climate-induced increases in soil carbon mineralization. The magnitude of this effect remains uncertain, due in large part to unknown temperature sensitivities of organic matter decomposition. In particular, the distribution of temperature sensitivities across soil carbon pools remains unknown. New experimental approaches are needed, because studies that fit multi-pool models to CO2 flux measurements may be sensitive to model assumptions, statistical effects, and non-steady-state changes in substrate availability or microbial activity. In this study, we developed a new methodology using natural abundance radiocarbon to evaluate temperature sensitivities across soil carbon pools. In two incubation experiments with soils from Barrow, AK, we (1) evaluated soil carbon age and decomposability, (2) disentangled the effects of temperature and substrate depletion on carbon mineralization, and (3) compared the temperature sensitivities of fast- and slow-cycling soil carbon pools. From a long-term incubation, both respired CO2 and the remaining soil organic matter were highly depleted in radiocarbon. At 20 cm depth, median Δ14C values were -167‰ in respired CO2 and -377‰ in soil organic matter, corresponding to turnover times of 1800 and 4800 years, respectively. Such negative Δ14C values indicate both storage and decomposition of old, stabilized carbon, while radiocarbon differences between the mineralized and non-mineralized fractions suggest that decomposability varies along a turnover time gradient. Applying a new analytical method combining CO2 flux and Δ14C, we found that fast- and slow-cycling carbon pools were equally sensitive to temperature, with a Q10 of 2 irrespective of turnover time. We conclude that in these Arctic soils, ancient soil carbon is vulnerable to warming under thawed, aerobic conditions. In contrast to many previous studies, we found no difference in temperature sensitivity of decomposition between fast- and slow-cycling pools. These findings suggest that in these soils, carbon stabilization mechanisms other than chemical recalcitrance mediate temperature sensitivities, and even old SOC will be readily decomposable as climate warms.
Sensitivity analysis of eigenvalues for an electro-hydraulic servomechanism
NASA Astrophysics Data System (ADS)
Stoia-Djeska, M.; Safta, C. A.; Halanay, A.; Petrescu, C.
2012-11-01
Electro-hydraulic servomechanisms (EHSM) are important components of flight control systems and their role is to control the movement of the flying control surfaces in response to the movement of the cockpit controls. As flight-control systems, the EHSMs have a fast dynamic response, a high power to inertia ratio and high control accuracy. The paper is devoted to the study of the sensitivity for an electro-hydraulic servomechanism used for an aircraft aileron action. The mathematical model of the EHSM used in this paper includes a large number of parameters whose actual values may vary within some ranges of uncertainty. It consists in a nonlinear ordinary differential equation system composed by the mass and energy conservation equations, the actuator movement equations and the controller equation. In this work the focus is on the sensitivities of the eigenvalues of the linearized homogeneous system, which are the partial derivatives of the eigenvalues of the state-space system with respect the parameters. These are obtained using a modal approach based on the eigenvectors of the state-space direct and adjoint systems. To calculate the eigenvalues and their sensitivity the system's Jacobian and its partial derivatives with respect the parameters are determined. The calculation of the derivative of the Jacobian matrix with respect to the parameters is not a simple task and for many situations it must be done numerically. The system stability is studied in relation with three parameters: m, the equivalent inertial load of primary control surface reduced to the actuator rod; B, the bulk modulus of oil and p a pressure supply proportionality coefficient. All the sensitivities calculated in this work are in good agreement with those obtained through recalculations.
Saa, Pedro A.; Nielsen, Lars K.
2016-01-01
Motivation: Computation of steady-state flux solutions in large metabolic models is routinely performed using flux balance analysis based on a simple LP (Linear Programming) formulation. A minimal requirement for thermodynamic feasibility of the flux solution is the absence of internal loops, which are enforced using ‘loopless constraints’. The resulting loopless flux problem is a substantially harder MILP (Mixed Integer Linear Programming) problem, which is computationally expensive for large metabolic models. Results: We developed a pre-processing algorithm that significantly reduces the size of the original loopless problem into an easier and equivalent MILP problem. The pre-processing step employs a fast matrix sparsification algorithm—Fast- sparse null-space pursuit (SNP)—inspired by recent results on SNP. By finding a reduced feasible ‘loop-law’ matrix subject to known directionalities, Fast-SNP considerably improves the computational efficiency in several metabolic models running different loopless optimization problems. Furthermore, analysis of the topology encoded in the reduced loop matrix enabled identification of key directional constraints for the potential permanent elimination of infeasible loops in the underlying model. Overall, Fast-SNP is an effective and simple algorithm for efficient formulation of loop-law constraints, making loopless flux optimization feasible and numerically tractable at large scale. Availability and Implementation: Source code for MATLAB including examples is freely available for download at http://www.aibn.uq.edu.au/cssb-resources under Software. Optimization uses Gurobi, CPLEX or GLPK (the latter is included with the algorithm). Contact: lars.nielsen@uq.edu.au Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27559155
Kalinina, Marina A; Skvortsov, Dmitry A; Rubtsova, Maria P; Komarova, Ekaterina S; Dontsova, Olga A
2018-06-01
High- and medium-throughput assays are now routine methods for drug screening and toxicology investigations on mammalian cells. However, a simple and cost-effective analysis of cytotoxicity that can be carried out with commonly used laboratory equipment is still required. The developed cytotoxicity assays are based on human cell lines stably expressing eGFP, tdTomato, mCherry, or Katushka2S fluorescent proteins. Red fluorescent proteins exhibit a higher signal-to-noise ratio, due to less interference by medium autofluorescence, in comparison to green fluorescent protein. Measurements have been performed on a fluorescence scanner, a plate fluorimeter, and a camera photodocumentation system. For a 96-well plate assay, the sensitivity per well and the measurement duration were 250 cells and 15 min for the scanner, 500 cells and 2 min for the plate fluorimeter, and 1000 cells and less than 1 min for the camera detection. These sensitivities are similar to commonly used MTT (tetrazolium dye) assays. The used scanner and the camera had not been previously applied for cytotoxicity evaluation. An image processing scheme for the high-resolution scanner is proposed that significantly diminishes the number of control wells, even for a library containing fluorescent substances. The suggested cytotoxicity assay has been verified by measurements of the cytotoxicity of several well-known cytotoxic drugs and further applied to test a set of novel bacteriotoxic compounds in a medium-throughput format. The fluorescent signal of living cells is detected without disturbing them and adding any reagents, thus allowing to investigate time-dependent cytotoxicity effects on the same sample of cells. A fast, simple and cost-effective assay is suggested for cytotoxicity evaluation based on mammalian cells expressing fluorescent proteins and commonly used laboratory equipment.
Design of a surface plasmon resonance immunoassay for therapeutic drug monitoring of amikacin.
Losoya-Leal, Adrian; Estevez, M-Carmen; Martínez-Chapa, Sergio O; Lechuga, Laura M
2015-08-15
The therapeutic drug monitoring (TDM) of pharmaceutical drugs with narrow therapeutic ranges is of great importance in the clinical setting. It provides useful information towards the enhancement of drug therapies, aiding in dosage control and toxicity risk management. Amikacin is an aminoglycoside antibiotic commonly used in neonatal therapies that is indicated for TDM due to the toxicity risks inherent in its use. Current techniques for TDM such as high performance liquid chromatography (HPLC) and gas chromatography-mass spectrometry (GC-MS) are costly, time consuming, and cannot be performed at the site of action. Over the last decades, surface plasmon resonance (SPR) biosensors have become increasingly popular in clinical diagnostics due to their ability to detect biomolecular interactions in real-time. We present an SPR-based competitive immunoassay for the detection of the antibiotic amikacin, suitable for TDM in both adults and neonates. We have obtained high specificity and sensitivity levels with an IC50 value of 1.4ng/mL and a limit of detection of 0.13ng/mL, which comfortably comply with the drug's therapeutic range. Simple dilution of serum can therefore be sufficient to analyze low-volume real samples from neonates, increasing the potential of the methodology for TDM. Compared to current TDM conventional methods, this SPR-based immunoassay can provide advantages such as simplicity, potential portability, and label-free measurements with the possibility of high throughput. This work is the foundation towards the development of an integrated, simple use, highly sensitive, fast, and point-of-care sensing platform for the opportune TDM of antibiotics and other drugs in a clinical setting. Copyright © 2015 Elsevier B.V. All rights reserved.
Working Memory Load Strengthens Reward Prediction Errors.
Collins, Anne G E; Ciullo, Brittany; Frank, Michael J; Badre, David
2017-04-19
Reinforcement learning (RL) in simple instrumental tasks is usually modeled as a monolithic process in which reward prediction errors (RPEs) are used to update expected values of choice options. This modeling ignores the different contributions of different memory and decision-making systems thought to contribute even to simple learning. In an fMRI experiment, we investigated how working memory (WM) and incremental RL processes interact to guide human learning. WM load was manipulated by varying the number of stimuli to be learned across blocks. Behavioral results and computational modeling confirmed that learning was best explained as a mixture of two mechanisms: a fast, capacity-limited, and delay-sensitive WM process together with slower RL. Model-based analysis of fMRI data showed that striatum and lateral prefrontal cortex were sensitive to RPE, as shown previously, but, critically, these signals were reduced when the learning problem was within capacity of WM. The degree of this neural interaction related to individual differences in the use of WM to guide behavioral learning. These results indicate that the two systems do not process information independently, but rather interact during learning. SIGNIFICANCE STATEMENT Reinforcement learning (RL) theory has been remarkably productive at improving our understanding of instrumental learning as well as dopaminergic and striatal network function across many mammalian species. However, this neural network is only one contributor to human learning and other mechanisms such as prefrontal cortex working memory also play a key role. Our results also show that these other players interact with the dopaminergic RL system, interfering with its key computation of reward prediction errors. Copyright © 2017 the authors 0270-6474/17/374332-11$15.00/0.
15 CFR Supplement No. 6 to Part 774 - Sensitive List
Code of Federal Regulations, 2014 CFR
2014-01-01
... filtering and beamforming using Fast Fourier or other transforms or processes. (vi) 6A001.a.2.d. (vii) 6A001... processing and correlation, including spectral analysis, digital filtering and beamforming using Fast Fourier...
Huxel Bliven, Kellie C; Snyder Valier, Alison R; Bay, R Curtis; Sauers, Eric L
2017-04-01
The Functional Arm Scale for Throwers (FAST) is an upper extremity (UE) region-specific and population-specific patient-reported outcome (PRO) scale developed to measure health-related quality of life in throwers with UE injuries. Stages I and II, described in a companion paper, of FAST development produced a 22-item scale and a 9-item pitcher module. Stage III of scale development, establishing reliability and validity of the FAST, is reported herein. To describe stage III of scale development: reliability and validity of the FAST. Cohort study (diagnosis); Level of evidence, 2. Data from throwing athletes collected over 5 studies were pooled to assess reliability and validity of the FAST. Reliability was estimated using FAST scores from 162 throwing athletes who were injured (n = 23) and uninjured (n = 139). Concurrent validity was estimated using FAST scores and Disabilities of the Arm, Shoulder, and Hand (DASH) and Kerlan-Jobe Orthopaedic Clinic (KJOC) scores from 106 healthy, uninjured throwing athletes. Known-groups validity was estimated using FAST scores from 557 throwing athletes who were injured (n = 142) and uninjured (n = 415). Reliability and validity were assessed using intraclass correlation coefficients (ICCs), and measurement error was assessed using standard error of measurement (SEM) and minimum detectable change (MDC). Receiver operating characteristic curves and sensitivity/specificity values were estimated for known-groups validity. Data from a separate group (n = 18) of postsurgical and nonoperative/conservative rehabilitation patients were analyzed to report responsiveness of the FAST. The FAST total, subscales, and pitcher module scores demonstrated excellent test-retest reliability (ICC, 0.91-0.98). The SEM 95 and MDC 95 for the FAST total score were 3.8 and 10.5 points, respectively. The SEM 95 and MDC 95 for the pitcher module score were 5.7 and 15.7 points, respectively. The FAST scores showed acceptable correlation with DASH (ICC, 0.49-0.82) and KJOC (ICC, 0.62-0.81) scores. The FAST total score classified 85.1% of players into the correct injury group. For predicting UE injury status, a FAST total cutoff score of 10.0 out of 100.0 was 91% sensitive and 75% specific, and a pitcher module score of 10.0 out of 100.0 was 87% sensitive and 78% specific. The FAST total score demonstrated responsiveness on several indices between intake and discharge time points. The FAST is a reliable, valid, and responsive UE region-specific and population-specific PRO scale for measuring patient-reported health care outcomes in throwing athletes with injury.
Huxel Bliven, Kellie C.; Snyder Valier, Alison R.; Bay, R. Curtis; Sauers, Eric L.
2017-01-01
Background: The Functional Arm Scale for Throwers (FAST) is an upper extremity (UE) region-specific and population-specific patient-reported outcome (PRO) scale developed to measure health-related quality of life in throwers with UE injuries. Stages I and II, described in a companion paper, of FAST development produced a 22-item scale and a 9-item pitcher module. Stage III of scale development, establishing reliability and validity of the FAST, is reported herein. Purpose: To describe stage III of scale development: reliability and validity of the FAST. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Data from throwing athletes collected over 5 studies were pooled to assess reliability and validity of the FAST. Reliability was estimated using FAST scores from 162 throwing athletes who were injured (n = 23) and uninjured (n = 139). Concurrent validity was estimated using FAST scores and Disabilities of the Arm, Shoulder, and Hand (DASH) and Kerlan-Jobe Orthopaedic Clinic (KJOC) scores from 106 healthy, uninjured throwing athletes. Known-groups validity was estimated using FAST scores from 557 throwing athletes who were injured (n = 142) and uninjured (n = 415). Reliability and validity were assessed using intraclass correlation coefficients (ICCs), and measurement error was assessed using standard error of measurement (SEM) and minimum detectable change (MDC). Receiver operating characteristic curves and sensitivity/specificity values were estimated for known-groups validity. Data from a separate group (n = 18) of postsurgical and nonoperative/conservative rehabilitation patients were analyzed to report responsiveness of the FAST. Results: The FAST total, subscales, and pitcher module scores demonstrated excellent test-retest reliability (ICC, 0.91-0.98). The SEM95 and MDC95 for the FAST total score were 3.8 and 10.5 points, respectively. The SEM95 and MDC95 for the pitcher module score were 5.7 and 15.7 points, respectively. The FAST scores showed acceptable correlation with DASH (ICC, 0.49-0.82) and KJOC (ICC, 0.62-0.81) scores. The FAST total score classified 85.1% of players into the correct injury group. For predicting UE injury status, a FAST total cutoff score of 10.0 out of 100.0 was 91% sensitive and 75% specific, and a pitcher module score of 10.0 out of 100.0 was 87% sensitive and 78% specific. The FAST total score demonstrated responsiveness on several indices between intake and discharge time points. Conclusion: The FAST is a reliable, valid, and responsive UE region-specific and population-specific PRO scale for measuring patient-reported health care outcomes in throwing athletes with injury. PMID:28451614
Artes, Paul H; Iwase, Aiko; Ohno, Yuko; Kitazawa, Yoshiaki; Chauhan, Balwantray C
2002-08-01
To investigate the distributions of threshold estimates with the Swedish Interactive Threshold Algorithms (SITA) Standard, SITA Fast, and the Full Threshold algorithm (Humphrey Field Analyzer; Zeiss-Humphrey Instruments, Dublin, CA) and to compare the pointwise test-retest variability of these strategies. One eye of 49 patients (mean age, 61.6 years; range, 22-81) with glaucoma (Mean Deviation mean, -7.13 dB; range, +1.8 to -23.9 dB) was examined four times with each of the three strategies. The mean and median SITA Standard and SITA Fast threshold estimates were compared with a "best available" estimate of sensitivity (mean results of three Full Threshold tests). Pointwise 90% retest limits (5th and 95th percentiles of retest thresholds) were derived to assess the reproducibility of individual threshold estimates. The differences between the threshold estimates of the SITA and Full Threshold strategies were largest ( approximately 3 dB) for midrange sensitivities ( approximately 15 dB). The threshold distributions of SITA were considerably different from those of the Full Threshold strategy. The differences remained of similar magnitude when the analysis was repeated on a subset of 20 locations that are examined early during the course of a Full Threshold examination. With sensitivities above 25 dB, both SITA strategies exhibited lower test-retest variability than the Full Threshold strategy. Below 25 dB, the retest intervals of SITA Standard were slightly smaller than those of the Full Threshold strategy, whereas those of SITA Fast were larger. SITA Standard may be superior to the Full Threshold strategy for monitoring patients with visual field loss. The greater test-retest variability of SITA Fast in areas of low sensitivity is likely to offset the benefit of even shorter test durations with this strategy. The sensitivity differences between the SITA and Full Threshold strategies may relate to factors other than reduced fatigue. They are, however, small in comparison to the test-retest variability.
Gelman, Hannah; Gruebele, Martin
2014-01-01
Fast folding proteins have been a major focus of computational and experimental study because they are accessible to both techniques: they are small and fast enough to be reasonably simulated with current computational power, but have dynamics slow enough to be observed with specially developed experimental techniques. This coupled study of fast folding proteins has provided insight into the mechanisms which allow some proteins to find their native conformation well less than 1 ms and has uncovered examples of theoretically predicted phenomena such as downhill folding. The study of fast folders also informs our understanding of even “slow” folding processes: fast folders are small, relatively simple protein domains and the principles that govern their folding also govern the folding of more complex systems. This review summarizes the major theoretical and experimental techniques used to study fast folding proteins and provides an overview of the major findings of fast folding research. Finally, we examine the themes that have emerged from studying fast folders and briefly summarize their application to protein folding in general as well as some work that is left to do. PMID:24641816
Ozbek, Nil; Akman, Suleyman
2012-05-30
Fluorine was determined via the rotational molecular absorption line of aluminum mono fluoride (AlF) generated in C(2)H(2)/N(2)O flame at 227.4613 nm using a high-resolution continuum source flame atomic absorption spectrophotometer (HR-CS-FAAS). The effects of AlF wavelength, burner height, fuel rate (C(2)H(2)/N(2)O) and amount of Al on the accuracy, precision and sensitivity were investigated and optimized. The Al-F absorption band at 227.4613 nm was found to be the most suitable analytical line with respect to sensitivity and spectral interferences. Maximum sensitivity and a good linearity were obtained in acetylene-nitrous oxide flame at a flow rate of 210 L h(-1) and a burner height of 8mm using 3000 mg L(-1) of Al for 10-1000 mg L(-1)of F. The accuracy and precision of the method were tested by analyzing spiked samples and waste water certified reference material. The results were in good agreement with the certified and spiked amounts as well as the precision of several days during this study was satisfactory (RSD<10%). The limit of detection and characteristic concentration of the method were 5.5 mg L(-1) and 72.8 mg L(-1), respectively. Finally, the fluorine concentrations in several toothpaste samples were determined. The results found and given by the producers were not significantly different. The method was simple, fast, accurate and sensitive. Copyright © 2012 Elsevier B.V. All rights reserved.
Daikhin, Luba; Ahissar, Merav
2015-07-01
Introducing simple stimulus regularities facilitates learning of both simple and complex tasks. This facilitation may reflect an implicit change in the strategies used to solve the task when successful predictions regarding incoming stimuli can be formed. We studied the modifications in brain activity associated with fast perceptual learning based on regularity detection. We administered a two-tone frequency discrimination task and measured brain activation (fMRI) under two conditions: with and without a repeated reference tone. Although participants could not explicitly tell the difference between these two conditions, the introduced regularity affected both performance and the pattern of brain activation. The "No-Reference" condition induced a larger activation in frontoparietal areas known to be part of the working memory network. However, only the condition with a reference showed fast learning, which was accompanied by a reduction of activity in two regions: the left intraparietal area, involved in stimulus retention, and the posterior superior-temporal area, involved in representing auditory regularities. We propose that this joint reduction reflects a reduction in the need for online storage of the compared tones. We further suggest that this change reflects an implicit strategic shift "backwards" from reliance mainly on working memory networks in the "No-Reference" condition to increased reliance on detected regularities stored in high-level auditory networks.
Highly sensitive graphene biosensor by monomolecular self-assembly of receptors on graphene surface
NASA Astrophysics Data System (ADS)
Kim, Ji Eun; No, Young Hyun; Kim, Joo Nam; Shin, Yong Seon; Kang, Won Tae; Kim, Young Rae; Kim, Kun Nyun; Kim, Yong Ho; Yu, Woo Jong
2017-05-01
Graphene has attracted a great deal of interest for applications in bio-sensing devices because of its ultra-thin structure, which enables strong electrostatic coupling with target molecules, and its excellent electrical mobility promising for ultra-fast sensing speeds. However, thickly stacked receptors on the graphene's surface interrupts electrostatic coupling between graphene and charged biomolecules, which can reduce the sensitivity of graphene biosensors. Here, we report a highly sensitive graphene biosensor by the monomolecular self-assembly of designed peptide protein receptors. The graphene channel was non-covalently functionalized using peptide protein receptors via the π-π interaction along the graphene's Bravais lattice, allowing ultra-thin monomolecular self-assembly through the graphene lattice. In thickness dependent characterization, a graphene sensor with a monomolecular receptor (thickness less than 3 nm) showed five times higher sensitivity and three times higher voltage shifts than graphene sensors with thick receptor stacks (thicknesses greater than 20 nm), which is attributed to excellent gate coupling between graphene and streptavidin via an ultrathin receptor insulator. In addition to having a fast-inherent response time (less than 0.6 s) based on fast binding speed between biotin and streptavidin, our graphene biosensor is a promising platform for highly sensitive real-time monitoring of biomolecules with high spatiotemporal resolution.
Kemeny, Steven Frank; Clyne, Alisa Morss
2011-04-01
Fiber alignment plays a critical role in the structure and function of cells and tissues. While fiber alignment quantification is important to experimental analysis and several different methods for quantifying fiber alignment exist, many studies focus on qualitative rather than quantitative analysis perhaps due to the complexity of current fiber alignment methods. Speed and sensitivity were compared in edge detection and fast Fourier transform (FFT) for measuring actin fiber alignment in cells exposed to shear stress. While edge detection using matrix multiplication was consistently more sensitive than FFT, image processing time was significantly longer. However, when MATLAB functions were used to implement edge detection, MATLAB's efficient element-by-element calculations and fast filtering techniques reduced computation cost 100 times compared to the matrix multiplication edge detection method. The new computation time was comparable to the FFT method, and MATLAB edge detection produced well-distributed fiber angle distributions that statistically distinguished aligned and unaligned fibers in half as many sample images. When the FFT sensitivity was improved by dividing images into smaller subsections, processing time grew larger than the time required for MATLAB edge detection. Implementation of edge detection in MATLAB is simpler, faster, and more sensitive than FFT for fiber alignment quantification.
Arrabal-Polo, Miguel Ángel; del Carmen Cano-García, María; Arrabal-Martín, Miguel
2016-04-01
To determine the importance of fasting calcium/creatinine ratio in patients with calcium stones and its relation with hypercalciuria and phospho-calcium metabolism. Cross-sectional study including 143 patients divided into two groups according to fasting calcium/creatinine. Group 1: 66 patients (calcium/ creatinine<0.11); Group 2: 77 patients (calcium/ creatinine>0.11). A comparative study is performed between groups including phospho-calcium metabolism parameters and excretion of urinary lithogenic markers. Linear correlation studying calciuria and fasting calcium/ creatinine was performed. SPSS 17.0 statistical analysis software was used, considering p≤0.05. It is noteworthy that group 2 had increased 24 h urine calcium excretion in comparison to group 1 (229.3 vs 158.1; p=0.0001) and calcium/citrate (0.47 vs 0.34; p=0.001). There is a positive and significant correlation between calcium levels in 24 h urine and fasting calcium/creatinine (R=0.455; p=0.0001) and a cutoff is set at 0.127 (sensitivity 72%, specificity 66%) to determine hypercalciuria (>260 mg in 24 h). Increased fasting calcium/creatinine determines increased 24 hours calcium excretion, although the sensitivity and specificity to determine hypercalciuria is not high.
Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M
2017-01-01
Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.
Glicksman, Michael; Asthana, Asha; Abel, Brent S; Walter, Mary F; Skarulis, Monica C; Muniyappa, Ranganath
2017-03-01
Pancreatic β -cell dysfunction because of reduced β -cell mass and function is a primary determinant in the progression of diabetes. Increase in β -cell mass and compensatory hyperinsulinaemia is frequently associated with insulin-resistant states. Although the humoral factors mediating this compensatory response are unknown, serpinB1, a protease inhibitor, has recently been proposed to be one such factor. In this study, we examine the relationships between plasma serpinB1, insulin sensitivity, and pancreatic β -cell function in non-diabetic individuals. 117 subjects (women, n = 50, men, n = 67; age= 37.6 ± 10.8; BMI=31.1 ± 7.7 kg/m 2 ) underwent an insulin-modified frequently sampled intravenous glucose tolerance test (FSIVGTT) at the NIH Clinical Research Center. Acute insulin response (AIR) and insulin sensitivity index (SI) were obtained from the FSIVGTT with MINMOD analysis. The Quantitative Insulin Sensitivity Check Index (QUICKI) was calculated from fasting insulin and glucose values. Plasma serpinB1 levels were measured using an ELISA assay. Simple linear correlation analyses were performed to evaluate the relationship between serpinB1 and measures of insulin sensitivity and β -cell function. Circulating serpinB1 levels were unrelated to age, sex, race, BMI, or percent body fat. SI but not AIR significantly correlated with circulating serpinB1 levels ( r = 0.23, P < 0.05). QUICKI tended to positively correlate with serpinB1 ( r = 0.16, P = 0.09). Circulating serpinB1 is directly associated with insulin sensitivity but not β -cell function in non-diabetic adults. Whether this modest association plays a role in insulin sensitivity in humans remains to be clarified. Published [2017]. This article is a U.S. Government work and is in the public domain in the USA.
eFAST for Pneumothorax: Real-Life Application in an Urban Level 1 Center by Trauma Team Members.
Maximus, Steven; Figueroa, Cesar; Whealon, Matthew; Pham, Jacqueline; Kuncir, Eric; Barrios, Cristobal
2018-02-01
The focused assessment with sonography for trauma (FAST) examination has become the standard of care for rapid evaluation of trauma patients. Extended FAST (eFAST) is the use of ultrasonography for the detection of pneumothorax (PTX). The exact sensitivity and specificity of eFAST detecting traumatic PTX during practical "real-life" application is yet to be investigated. This is a retrospective review of all trauma patients with a diagnosis of PTX, who were treated at a large level 1 urban trauma center from March 2013 through July 2014. Charts were reviewed for results of imaging, which included eFAST, chest X-ray, and CT scan. The requirement of tube thoracostomy and mechanism of injury were also analyzed. A total of 369 patients with a diagnosis of PTX were identified. A total of 69 patients were excluded, as eFAST was either not performed or not documented, leaving 300 patients identified with PTX. A total of 113 patients had clinically significant PTX (37.6%), requiring immediate tube thoracostomy placement. eFAST yielded a positive diagnosis of PTX in 19 patients (16.8%), and all were clinically significant, requiring tube thoracostomy. Chest X-ray detected clinically significant PTX in 105 patients (92.9%). The literature on the utility of eFAST for PTX in trauma is variable. Our data show that although specific for clinically significant traumatic PTX, it has poor sensitivity when performed by clinicians with variable levels of ultrasound training. We conclude that CT is still the gold standard in detecting PTX, and clinicians performing eFAST should have adequate training.
Automated and fast building of three-dimensional RNA structures.
Zhao, Yunjie; Huang, Yangyu; Gong, Zhou; Wang, Yanjie; Man, Jianfen; Xiao, Yi
2012-01-01
Building tertiary structures of non-coding RNA is required to understand their functions and design new molecules. Current algorithms of RNA tertiary structure prediction give satisfactory accuracy only for small size and simple topology and many of them need manual manipulation. Here, we present an automated and fast program, 3dRNA, for RNA tertiary structure prediction with reasonable accuracy for RNAs of larger size and complex topology.
Fast Simulation of the Impact Parameter Calculation of Electrons through Pair Production
NASA Astrophysics Data System (ADS)
Bang, Hyesun; Kweon, MinJung; Huh, Kyoung Bum; Pachmayer, Yvonne
2018-05-01
A fast simulation method is introduced that reduces tremendously the time required for the impact parameter calculation, a key observable in physics analyses of high energy physics experiments and detector optimisation studies. The impact parameter of electrons produced through pair production was calculated considering key related processes using the Bethe-Heitler formula, the Tsai formula and a simple geometric model. The calculations were performed at various conditions and the results were compared with those from full GEANT4 simulations. The computation time using this fast simulation method is 104 times shorter than that of the full GEANT4 simulation.
Not so fast! (and not so frugal!): rethinking the recognition heuristic.
Oppenheimer, Daniel M
2003-11-01
The 'fast and frugal' approach to reasoning (Gigerenzer, G., & Todd, P. M. (1999). Simple heuristics that make us smart. New York: Oxford University Press) claims that individuals use non-compensatory strategies in judgment--the idea that only one cue is taken into account in reasoning. The simplest and most important of these heuristics postulates that judgment sometimes relies solely on recognition. However, the studies that have investigated usage of the recognition heuristic have confounded recognition with other cues that could also lead to similar judgments. This paper tests whether mere recognition is actually driving the findings in support of the recognition heuristic. Two studies provide evidence that judgments do not conform to the recognition heuristic when these confounds are accounted for. Implications for the study of simple heuristics are discussed.
Wang, Tiange; Huang, Tao; Zheng, Yan; Rood, Jennifer; Bray, George A.; Sacks, Frank M.; Qi, Lu
2016-01-01
Objective Weight loss intervention through diet modification has been widely used to improve obesity-related hyperglycemia; however, little is known about whether genetic variation modifies the intervention effect. We examined the interaction between weight-loss diets and genetic variation of fasting glucose on changes in glycemic traits in a dietary intervention trial. Research Design and Methods The Preventing Overweight Using Novel Dietary Strategies (POUNDS LOST) trial is a randomized, controlled 2-year weight-loss trial. We assessed overall genetic variation of fasting glucose by calculating a genetic risk score (GRS) based on 14 fasting glucose-associated single nucleotide polymorphisms, and examined the progression in fasting glucose and insulin levels, and insulin resistance and insulin sensitivity in 733 adults from this trial. Results The GRS was associated with 6-month changes in fasting glucose (P<0.001), fasting insulin (P=0.042), homeostasis model assessment of insulin resistance (HOMA-IR, P=0.009) and insulin sensitivity (HOMA-S, P=0.043). We observed significant interaction between the GRS and dietary fat on 6-month changes in fasting glucose, HOMA-IR and HOMA-S after multivariable adjustment (P-interaction=0.007, 0.045, and 0.028, respectively). After further adjustment for weight loss, the interaction remained significant on change in fasting glucose (P=0.015). In the high-fat diet group, participants in the highest GRS tertile showed increased fasting glucose, whereas participants in the lowest tertile showed decreased fasting glucose (P-trend<0.001); in contrast, the genetic association was not significant in the low-fat diet group (P-trend=0.087). Conclusions Our data suggest that participants with a higher genetic risk may benefit more by eating a low-fat diet to improve glucose metabolism. PMID:27113490
Wang, T; Huang, T; Zheng, Y; Rood, J; Bray, G A; Sacks, F M; Qi, L
2016-07-01
Weight-loss intervention through diet modification has been widely used to improve obesity-related hyperglycemia; however, little is known about whether genetic variation modifies the intervention effect. We examined the interaction between weight-loss diets and genetic variation of fasting glucose on changes in glycemic traits in a dietary intervention trial. The Preventing Overweight Using Novel Dietary Strategies (POUNDS LOST) trial is a randomized, controlled 2-year weight-loss trial. We assessed overall genetic variation of fasting glucose by calculating a genetic risk score (GRS) based on 14 fasting glucose-associated single nucleotide polymorphisms, and examined the progression in fasting glucose and insulin levels, and insulin resistance and insulin sensitivity in 733 adults from this trial. The GRS was associated with 6-month changes in fasting glucose (P<0.001), fasting insulin (P=0.042), homeostasis model assessment of insulin resistance (HOMA-IR, P=0.009) and insulin sensitivity (HOMA-S, P=0.043). We observed significant interaction between the GRS and dietary fat on 6-month changes in fasting glucose, HOMA-IR and HOMA-S after multivariable adjustment (P-interaction=0.007, 0.045 and 0.028, respectively). After further adjustment for weight loss, the interaction remained significant on change in fasting glucose (P=0.015). In the high-fat diet group, participants in the highest GRS tertile showed increased fasting glucose, whereas participants in the lowest tertile showed decreased fasting glucose (P-trend <0.001); in contrast, the genetic association was not significant in the low-fat diet group (P-trend=0.087). Our data suggest that participants with a higher genetic risk may benefit more by eating a low-fat diet to improve glucose metabolism.
Viscarra, Jose A; Rodriguez, Ruben; Vazquez-Medina, Jose Pablo; Lee, Andrew; Tift, Michael S; Tavoni, Stephen K; Crocker, Daniel E; Ortiz, Rudy M
2013-08-01
Prolonged food deprivation increases lipid oxidation and utilization, which may contribute to the onset of the insulin resistance associated with fasting. Because insulin resistance promotes the preservation of glucose and oxidation of fat, it has been suggested to be an adaptive response to food deprivation. However, fasting mammals exhibit hypoinsulinemia, suggesting that the insulin resistance-like conditions they experience may actually result from reduced pancreatic sensitivity to glucose/capacity to secrete insulin. To determine whether fasting results in insulin resistance or in pancreatic dysfunction, we infused early- and late-fasted seals (naturally adapted to prolonged fasting) with insulin (0.065 U/kg), and a separate group of late-fasted seals with low (10 pM/kg) or high (100 pM/kg) dosages of glucagon-like peptide-1 (GLP-1) immediately following a glucose bolus (0.5g/kg), and measured the systemic and cellular responses. Because GLP-1 facilitates glucose-stimulated insulin secretion, these infusions provide a method to assess pancreatic insulin-secreting capacity. Insulin infusions increased the phosphorylation of insulin receptor and Akt in adipose and muscle of early and late fasted seals; however the timing of the signaling response was blunted in adipose of late fasted seals. Despite the dose-dependent increases in insulin and increased glucose clearance (high dose), both GLP-1 dosages produced increases in plasma cortisol and glucagon, which may have contributed to the glucogenic role of GLP-1. Results suggest that fasting induces adipose-specific insulin resistance in elephant seal pups, while maintaining skeletal muscle insulin sensitivity, and therefore suggests that the onset of insulin resistance in fasting mammals is an evolved response to cope with prolonged food deprivation.
Subthreshold neutron interrogator for detection of radioactive materials
Evans, Michael L.; Menlove, Howard O.; Baker, Michael P.
1980-01-01
A device for detecting fissionable material such as uranium in low concentrations by interrogating with photoneutrons at energy levels below 500 keV, and typically about 26 keV. Induced fast neutrons having energies above 500 keV by the interrogated fissionable material are detected by a liquid scintillator or recoil proportional counter which is sensitive to the induced fast neutrons. Since the induced fast neutrons are proportional to the concentration of fissionable material, detection of induced fast neutrons indicate concentration of the fissionable material.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hannan, M.A.; Gibson, D.P.
1985-10-01
The sensitizing effects of caffeine were studied in baby hamster kidney (BHK-21) cells and human lymphocytes following irradiation with gamma rays and fast neutrons. Caffeine sensitization occurred only when log-phase BHK cells and mitogen-stimulated lymphocytes were exposed to the two radiations. Noncycling (confluent) cells of BHK resulted in a shouldered survival curve following gamma irradiation while a biphasic curve was obtained with the log-phase cells. Survival in the case of lymphocytes was estimated by measurement of (TH)thymidine uptake. The relative biological effectiveness (RBE) of fast neutrons was found to be greater at survival levels corresponding to the resistant portions ofmore » the survival curves (shoulder or resistant tail). In both cell types, no reduction in RBE was observed when caffeine was present, because caffeine affected both gamma and neutron survival by the same proportion.« less
Breakdown of Spatial Parallel Coding in Children's Drawing
ERIC Educational Resources Information Center
De Bruyn, Bart; Davis, Alyson
2005-01-01
When drawing real scenes or copying simple geometric figures young children are highly sensitive to parallel cues and use them effectively. However, this sensitivity can break down in surprisingly simple tasks such as copying a single line where robust directional errors occur despite the presence of parallel cues. Before we can conclude that this…
DeBoer, Mark D; Gurka, Matthew J
2010-08-01
The aim of this study was to compare currently proposed sets of pediatric metabolic syndrome criteria for the ability to predict elevations in "surrogate" factors that are associated with metabolic syndrome and with future cardiovascular disease and type 2 diabetes mellitus. These surrogate factors were fasting insulin, hemoglobin A1c (HbA1c), high-sensitivity C-reactive protein (hsCRP), and uric acid. Waist circumference (WC), blood pressure, triglycerides, high-density lipoprotein cholesterol (HDL-C), fasting glucose, fasting insulin, HbA1c, hsCRP, and uric acid measurements were obtained from 2,624 adolescent (12-18 years old) participants of the 1999-2006 National Health and Nutrition Examination Surveys. We identified children with metabolic syndrome as defined by six commonly used sets of pediatric metabolic syndrome criteria. We then defined elevations in the surrogate factors as values in the top 5% for the cohort and calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for each set of metabolic syndrome criteria and for each surrogate factor. Current pediatric metabolic syndrome criteria exhibited variable sensitivity and specificity for surrogate predictions. Metabolic syndrome criteria had the highest sensitivity for predicting fasting insulin (40-70%), followed by uric acid (31-54%), hsCRP (13-31%), and HbA1c (7-21%). The criteria of de Ferranti (which includes children with WC >75(th) percentile, compared to all other sets including children with WC >90(th) percentile) exhibited the highest sensitivity for predicting each of the surrogates, with only modest decrease in specificity compared to the other sets of criteria. However, the de Ferranti criteria also exhibited the lowest PPV values. Conversely, the pediatric International Diabetes Federation criteria exhibited the lowest sensitivity and the highest specificity. Pediatric metabolic syndrome criteria exhibit moderate sensitivity for detecting elevations in surrogate factors associated with metabolic syndrome and with risk for future disease. Inclusion of children with more modestly elevated WC improved sensitivity.
Inexpensive and fast pathogenic bacteria screening using field-effect transistors.
Formisano, Nello; Bhalla, Nikhil; Heeran, Mel; Reyes Martinez, Juana; Sarkar, Amrita; Laabei, Maisem; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Flitsch, Sabine; Estrela, Pedro
2016-11-15
While pathogenic bacteria contribute to a large number of globally important diseases and infections, current clinical diagnosis is based on processes that often involve culturing which can be time-consuming. Therefore, innovative, simple, rapid and low-cost solutions to effectively reduce the burden of bacterial infections are urgently needed. Here we demonstrate a label-free sensor for fast bacterial detection based on metal-oxide-semiconductor field-effect transistors (MOSFETs). The electric charge of bacteria binding to the glycosylated gates of a MOSFET enables quantification in a straightforward manner. We show that the limit of quantitation is 1.9×10(5) CFU/mL with this simple device, which is more than 10,000-times lower than is achieved with electrochemical impedance spectroscopy (EIS) and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-ToF) on the same modified surfaces. Moreover, the measurements are extremely fast and the sensor can be mass produced at trivial cost as a tool for initial screening of pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.
Sun, Hui; Lai, Jia-Ping; Chen, Fang; Zhu, De-Rong
2015-02-01
A simple, fast, and universal suspension polymerization method was used to synthesize the molecularly imprinted microspheres (MIMs) for the topical anesthetic benzocaine (BZC). The desired diameter (10-20 μm) and uniform morphology of the MIMs were obtained easily by changing one or more of the synthesis conditions, including type and amount of surfactant, stirring rate, and ratio of organic to water phase. The MIMs obtained were used as a molecular-imprinting solid-phase-extraction (MISPE) material for extraction of BZC in human serum and fish tissues. The MISPE results revealed that the BZC in these biosamples could be enriched effectively after the MISPE operation. The recoveries of BZC on MIMs cartridges were higher than 90% (n = 3). Finally, an MISPE-HPLC method with UV detection was developed for highly selective extraction and fast detection of trace BZC in human serum and fish tissues. The developed method could also be used for the enrichment and detection of BZC in other complex biosamples.
A simple fast pulse gas valve using a dynamic pressure differential as the primary closing mechanism
NASA Astrophysics Data System (ADS)
Thomas, J. C.; Hwang, D. Q.; Horton, R. D.; Rogers, J. H.; Raman, R.
1993-06-01
In this article we describe a simple fast pulse gas valve developed for use in a plasma discharge experiment. The valve delivers 1017-1019 molecules per pulse varied by changing the voltage on the electromagnetic driver power supply. Valve pulse widths are observed to be less than 300 μs full width at half maximum with a rise time of less than 100 μs resulting in a maximum gas flow rate of ˜1022 molecules per second. An optical transmission technique was used to determine the mechanical opening and closing characteristics of the valve piston. A fast ionization gauge (FIG) was used for diagnosis of the temporal character of the gas pulse while the total gas throughput was determined by measuring the change in pressure per pulse in a small test chamber with a convectron tube gauge. Calibration of the FIG was accomplished by comparing the net change in pressure in a large chamber as measured by the FIG to the net change in pressure in a small test chamber as measured by the convectron tube gauge.
Lax-Friedrichs sweeping scheme for static Hamilton-Jacobi equations
NASA Astrophysics Data System (ADS)
Kao, Chiu Yen; Osher, Stanley; Qian, Jianliang
2004-05-01
We propose a simple, fast sweeping method based on the Lax-Friedrichs monotone numerical Hamiltonian to approximate viscosity solutions of arbitrary static Hamilton-Jacobi equations in any number of spatial dimensions. By using the Lax-Friedrichs numerical Hamiltonian, we can easily obtain the solution at a specific grid point in terms of its neighbors, so that a Gauss-Seidel type nonlinear iterative method can be utilized. Furthermore, by incorporating a group-wise causality principle into the Gauss-Seidel iteration by following a finite group of characteristics, we have an easy-to-implement, sweeping-type, and fast convergent numerical method. However, unlike other methods based on the Godunov numerical Hamiltonian, some computational boundary conditions are needed in the implementation. We give a simple recipe which enforces a version of discrete min-max principle. Some convergence analysis is done for the one-dimensional eikonal equation. Extensive 2-D and 3-D numerical examples illustrate the efficiency and accuracy of the new approach. To our knowledge, this is the first fast numerical method based on discretizing the Hamilton-Jacobi equation directly without assuming convexity and/or homogeneity of the Hamiltonian.
Mulpur, Pradyumna; Yadavilli, Sairam; Mulpur, Praharsha; Kondiparthi, Neeharika; Sengupta, Bishwambhar; Rao, Apparao M; Podila, Ramakrishna; Kamisetti, Venkataramaniah
2015-10-14
The relatively low sensitivity of fluorescence detection schemes, which are mainly limited by the isotropic nature of fluorophore emission, can be overcome by utilizing surface plasmon coupled emission (SPCE). In this study, we demonstrate directional emission from fluorophores on flexible Ag-C60 SPCE sensor platforms for point-of-care sensing, in healthcare and forensic sensing scenarios, with at least 10 times higher sensitivity than traditional fluorescence sensing schemes. Adopting the highly sensitive Ag-C60 SPCE platform based on glass and novel low-cost flexible substrates, we report the unambiguous detection of acid-fast Mycobacterium tuberculosis (Mtb) bacteria at densities as low as 20 Mtb mm(-2); from non-acid-fast bacteria (e.g., E. coli and S. aureus), and the specific on-site detection of acid-fast sperm cells in human semen samples. In combination with the directional emission and high-sensitivity of SPCE platforms, we also demonstrate the utility of smartphones that can replace expensive and cumbersome detectors to enable rapid hand-held detection of analytes in resource-limited settings; a much needed critical advance to biosensors, for developing countries.
Simental-Mendía, Luis E; Simental-Mendía, Esteban; Rodríguez-Hernández, Heriberto; Rodríguez-Morán, Martha; Guerrero-Romero, Fernando
2016-01-01
Introduction and aim. Given that early identification of non-alcoholic fatty liver disease (NAFLD) is an important issue for primary prevention of hepatic disease, the objectives of this study were to evaluate the efficacy of the product of triglyceride and glucose levels (TyG) for screening simple steatosis and non-alcoholic steatohepatitis (NASH) in asymptomatic women, and to compare its efficacy vs. other biomarkers for recognizing NAFLD. Asymptomatic women aged 20 to 65 years were enrolled into a cross-sectional study. The optimal values of TyG, for screening simple steatosis and NASH were established on a Receiver Operating Characteristic scatter plot; the sensitivity, specificity, and likelihood ratios of TyG index were estimated versus liver biopsy. According sensitivity and specificity, the efficacy of TyG was compared versus the well-known clinical biomarkers for recognizing NAFLD. A total of 50 asymptomatic women were enrolled. The best cutoff point of TyG for screening simple steatosis was 4.58 (sensitivity 0.94, specificity 0.69); in addition, the best cutoff point of TyG index for screening NASH was 4.59 (sensitivity 0.87, specificity 0.69). The positive and negative likelihood ratios were 3.03 and 0.08 for simple steatosis, and 2.80 and 0.18 for NASH. As compared versus SteatoTest, NashTest, Fatty liver index, and Algorithm, the TyG showed to be the best test for screening. TyG has high sensitivity and low negative likelihood ratio; as compared with other clinical biomarkers, the TyG showed to be the best test for screening simple steatosis and NASH.
Iwasa, Takeshi; Matsuzaki, Toshiya; Tungalagsuvd, Altankhuu; Munkhzaya, Munkhsaikhan; Kawami, Takako; Yamasaki, Mikio; Murakami, Masahiro; Kato, Takeshi; Kuwahara, Akira; Yasui, Toshiyuki; Irahara, Minoru
2014-11-01
Prokineticin (PK2) and its receptors (PKRs) are expressed in several regions of the central nervous system, including the hypothalamus. It has been reported that PK2 inhibits food intake via PKR1 and that the hypothalamic PK2 mRNA levels of adult rodents were reduced by food deprivation. However, some hypothalamic factors do not exhibit sensitivity to undernutrition in the early neonatal period, but subsequently become sensitive to it during the neonatal to pre-pubertal period. In this study, we investigated the changes in the sensitivity of hypothalamic PK2 and PKR1 mRNA expression to fasting during the developmental period in male rats. Under the fed conditions, the rats' hypothalamic PK2 and/or PKR1 mRNA levels were higher on postnatal day (PND) 10 than on PND20 or PND30. In addition, the hypothalamic PK2 and/or PKR1 mRNA levels of the male rats were higher than those of the females at all examined ages (PND10, 20, and 30). Hypothalamic PK2 mRNA expression was decreased by 24h fasting at PND10 and 30, but not at PND20. In addition, hypothalamic PKR1 mRNA expression was decreased by 24h fasting at PND10, but not at PND20 or 30. These results indicate that both PK2 and PKR1 are sensitive to nutritional status in male rats and that this sensitivity has already been established by the early neonatal period. It can be speculated that the PK2 system might compensate for the immaturity of other appetite regulatory factors in the early neonatal period. Copyright © 2014 ISDN. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. Ditmire; Zweiback, J; Cowan, T E
In conclusion, we have observed the production of 2.45 MeV deuterium fusion neutrons when a gas of deuterium clusters is irradiated with a 120 mJ, 35 fs laser pulse. When the focal position is optimized, we have observed as many as 10{sup 4} neutrons per laser shot. This yield is consistent with some simple estimates for the fusion yield. We also find that the fusion yield is a sensitive function of the deuterium cluster size in the target jet, a consequence of the Coulomb explosion origin of the fast deuterons. We also find that the neutron pulse duration is fast,more » with a characteristic burn time of well under 1 ns. This experiment may represent a means for producing a compact, table-top source of short pulse fusion neutrons for applications. Furthermore, we have measured hard x-ray yield from femtosecond laser interactions with both solid and micron scale droplet targets. Strong hard x-ray production is observed from both targets. However, the inferred electron temperature is somewhat higher in the case of irradiation of the droplets. These data are consistent with PIC simulations. This finding indicates that quite unique hot electron dynamics occur during the irradiation of wavelength scale particles by an intense laser field and likely warrants further study.« less
Kim, Tae-Hyeong; Lim, Minji; Park, Juhee; Oh, Jung Min; Kim, Hyeongeun; Jeong, Hyunjin; Lee, Sun Ju; Park, Hee Chul; Jung, Sungmok; Kim, Byung Chul; Lee, Kyusang; Kim, Mi-Hyun; Park, Do Youn; Kim, Gwang Ha; Cho, Yoon-Kyoung
2017-01-17
Circulating tumor cells (CTCs) have great potential to provide minimally invasive ways for the early detection of cancer metastasis and for the response monitoring of various cancer treatments. Despite the clinical importance and progress of CTC-based cancer diagnostics, most of the current methods of enriching CTCs are difficult to implement in general hospital settings due to complex and time-consuming protocols. Among existing technologies, size-based isolation methods provide antibody-independent, relatively simple, and high throughput protocols. However, the clogging issues and lower than desired recovery rates and purity are the key challenges. In this work, inspired by antifouling membranes with liquid-filled pores in nature, clog-free, highly sensitive (95.9 ± 3.1% recovery rate), selective (>2.5 log depletion of white blood cells), rapid (>3 mL/min), and label-free isolation of viable CTCs from whole blood without prior sample treatment is achieved using a stand-alone lab-on-a-disc system equipped with fluid-assisted separation technology (FAST). Numerical simulation and experiments show that this method provides uniform, clog-free, ultrafast cell enrichment with pressure drops much less than in conventional size-based filtration, at 1 kPa. We demonstrate the clinical utility of the point-of-care detection of CTCs with samples taken from 142 patients suffering from breast, stomach, or lung cancer.
Electrochemical Genosensing of Circulating Biomarkers
Campuzano, Susana; Yáñez-Sedeño, Paloma; Pingarrón, José Manuel
2017-01-01
Management and prognosis of diseases requires the measurement in non- or minimally invasively collected samples of specific circulating biomarkers, consisting of any measurable or observable factors in patients that indicate normal or disease-related biological processes or responses to therapy. Therefore, on-site, fast and accurate determination of these low abundance circulating biomarkers in scarcely treated body fluids is of great interest for health monitoring and biological applications. In this field, electrochemical DNA sensors (or genosensors) have demonstrated to be interesting alternatives to more complex conventional strategies. Currently, electrochemical genosensors are considered very promising analytical tools for this purpose due to their fast response, low cost, high sensitivity, compatibility with microfabrication technology and simple operation mode which makes them compatible with point-of-care (POC) testing. In this review, the relevance and current challenges of the determination of circulating biomarkers related to relevant diseases (cancer, bacterial and viral infections and neurodegenerative diseases) are briefly discussed. An overview of the electrochemical nucleic acid–based strategies developed in the last five years for this purpose is given to show to both familiar and non-expert readers the great potential of these methodologies for circulating biomarker determination. After highlighting the main features of the reported electrochemical genosensing strategies through the critical discussion of selected examples, a conclusions section points out the still existing challenges and future directions in this field. PMID:28420103
Gibson, Desmond; MacGregor, Calum
2013-01-01
This paper describes development of a novel mid-infrared light emitting diode (LED) and photodiode (PD) light source/detector combination and use within a non-dispersive infrared (NDIR) carbon dioxide gas sensor. The LED/PD based NDIR sensor provides fast stabilisation time (time required to turn on the sensor from cold, warm up, take and report a measurement, and power down again ≈1 second), longevity (>15 years), low power consumption and low cost. Described performance is compatible with “fit and forget” wireless deployed sensors in applications such as indoor air quality monitoring/control & energy conservation in buildings, transport systems, horticultural greenhouses and portable deployment for safety, industrial and medical applications. Fast stabilisation time, low intrinsic power consumption and cycled operation offer typical energy consumption per measurement of mJ's, providing extended operation using battery and/or energy harvesting strategies (measurement interval of ≈ 2 minutes provides >10 years operation from one AA battery). Specific performance data is provided in relation to measurement accuracy and noise, temperature performance, cross sensitivity, measurement range (two pathlength variants are described covering ambient through to 100% gas concentration), comparison with NDIR utilizing thermal source/pyroelectric light source/detector combination and compatibility with energy harvesting. Semiconductor based LED/PD processing together with injection moulded reflective optics and simple assembly provide a route to low cost high volume manufacturing. PMID:23760090
Gibson, Desmond; MacGregor, Calum
2013-05-29
This paper describes development of a novel mid-infrared light emitting diode (LED) and photodiode (PD) light source/detector combination and use within a non-dispersive infrared (NDIR) carbon dioxide gas sensor. The LED/PD based NDIR sensor provides fast stabilisation time (time required to turn on the sensor from cold, warm up, take and report a measurement, and power down again ≈1 second), longevity (>15 years), low power consumption and low cost. Described performance is compatible with "fit and forget" wireless deployed sensors in applications such as indoor air quality monitoring/control & energy conservation in buildings, transport systems, horticultural greenhouses and portable deployment for safety, industrial and medical applications. Fast stabilisation time, low intrinsic power consumption and cycled operation offer typical energy consumption per measurement of mJ's, providing extended operation using battery and/or energy harvesting strategies (measurement interval of ≈ 2 minutes provides >10 years operation from one AA battery). Specific performance data is provided in relation to measurement accuracy and noise, temperature performance, cross sensitivity, measurement range (two pathlength variants are described covering ambient through to 100% gas concentration), comparison with NDIR utilizing thermal source/pyroelectric light source/detector combination and compatibility with energy harvesting. Semiconductor based LED/PD processing together with injection moulded reflective optics and simple assembly provide a route to low cost high volume manufacturing.
Staaf, Johan; Labmayr, Viktor; Paulmichl, Katharina; Manell, Hannes; Cen, Jing; Ciba, Iris; Dahlbom, Marie; Roomp, Kirsten; Anderwald, Christian-Heinz; Meissnitzer, Matthias; Schneider, Reinhard; Forslund, Anders; Widhalm, Kurt; Bergquist, Jonas; Ahlström, Håkan; Bergsten, Peter; Weghuber, Daniel; Kullberg, Joel
2017-03-01
Adolescents with obesity have increased risk of type 2 diabetes and metabolic syndrome (MetS). Pancreatic fat has been related to these conditions; however, little is known about associations in pediatric obesity. The present study was designed to explore these associations further. We examined 116 subjects, 90 with obesity. Anthropometry, MetS, blood samples, and oral glucose tolerance tests were assessed using standard techniques. Pancreatic fat fraction (PFF) and other fat depots were quantified using magnetic resonance imaging. The PFF was elevated in subjects with obesity. No association between PFF and body mass index-standard deviation score (BMI-SDS) was found in the obesity subcohort. Pancreatic fat fraction correlated to Insulin Secretion Sensitivity Index-2 and Homeostatic Model Assessment of Insulin Resistance in simple regression; however, when using adjusted regression and correcting for BMI-SDS and other fat compartments, PFF correlated only to visceral adipose tissue and fasting glucose. Highest levels of PFF were found in subjects with obesity and MetS. In adolescents with obesity, PFF is elevated and associated to MetS, fasting glucose, and visceral adipose tissue but not to beta-cell function, glucose tolerance, or BMI-SDS. This study demonstrates that conclusions regarding PFF and its associations depend on the body mass features of the cohort.
Salomone, Alberto; Gerace, Enrico; Brizio, Paola; Gennaro, M Carla; Vincenti, Marco
2011-11-01
A fast liquid chromatographic/tandem mass spectrometric method was developed for the simultaneous determination in human urine of seventeen benzodiazepines, four relevant metabolites together plus zolpidem and zopiclone. The sample preparation, optimized to take into account the matrix effect, was based on enzymatic hydrolysis and liquid-liquid extraction. The separation of the twenty-three analytes was achieved in less than eight minutes. The whole methodology was fully validated according to UNI EN ISO/IEC 17025:2005 rules and 2006 SOFT/AAFS guidelines. Selectivity, linearity range, identification (LOD) and quantitation (LOQ) limits, precision, accuracy and recovery were evaluated. For all the species the signal/concentration linearity was satisfactory in the 50-1000 ng/mL concentration range. The limits of detection ranged from 0.5 to 30 ng/mL and LOQs from 1.7 to 100.0 ng/mL. Precisions were in the ranges 5.0-11.8%, 1.5-11.0% and 1.1-4.4% for low (100 ng/mL), medium (300 ng/mL) and high (1000 ng/mL) concentration, respectively. The accuracy, expressed as bias% was within ± 25 % for all the analytes. The recovery values, evaluated at 300 ng/mL concentration, ranged from 56.2% to 98.8%. The present method for the determination of several benzodiazepines, zolpidem and zopiclone in human urine proved to be simple, fast, specific and sensitive. The quantification by LC-MS/MS was successfully applied to 329 forensic cases among driving re-licensing, car accidents and alleged sexual violence cases. Copyright © 2011 Elsevier B.V. All rights reserved.
4D x-ray phase contrast tomography for repeatable motion of biological samples
NASA Astrophysics Data System (ADS)
Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto
2016-09-01
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
4D x-ray phase contrast tomography for repeatable motion of biological samples.
Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto
2016-09-01
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm 3 . A maximum volume size of 13 × 13 × 6 mm 3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
Development of a microplate coagulation assay for Factor V in human plasma.
Tilley, Derek; Levit, Irina; Samis, John A
2011-06-28
Factor V (FV) in its activated form, FVa, is a critical regulator of thrombin generation during fibrin clot formation. There is a need of a simple, fast, and inexpensive microplate-based coagulation assay to measure the functional activity of FV in human plasma. The objective of this study was to develop a microplate-based assay that measures FV coagulation activity during clot formation in human plasma, which is currently not available. The FV assay requires a kinetic microplate reader to measure the change in absorbance at 405nm during fibrin formation in human plasma. The FV assay accurately measures the time, initial rate, and extent of fibrin clot formation in human plasma. The FV microplate assay is simple, fast, economical, sensitive to approx 24-80pM, and multiple samples may be analyzed simultaneously. All the required materials are commercially available. Standard curves of time or initial rate of fibrin clot formation vs FV activity in the 1-stage assay (Without activation by thrombin) may be used to measure FV activity in samples of human plasma. The assay was used to demonstrate that in nine patients with disseminated intravascular coagulation (DIC), the FV 1-stage, 2-stage (With activation by thrombin), and total (2-stage activity - 1-stage activity) activities were decreased, on average, by approximately 54%, 44%, and 42%, respectively, from prolonged clot times when compared to normal pooled human reference plasma (NHP). The results indicate that the FV in the DIC patient plasmas supported both a delayed and slower rate of fibrin clot formation compared with NHP; however, the extent of fibrin clot formation in the DIC patients remained largely unchanged from that observed with NHP. The FV microplate assay may be easily adapted to measure the activity of any coagulation factor using the appropriate factor-deficient plasma and clot initiating reagent. The microplate assay will find use in both research and clinical laboratories to provide measurement of the functional coagulation activity of FV in human plasma.
Khan, Amjad; Iqbal, Zafar; Khadra, Ibrahim; Ahmad, Lateef; Khan, Abad; Khan, Muhammad Imran; Ullah, Zia; Ismail
2016-03-20
Domperidone and Itopride are pro-kinetic agents, regulating the gastric motility and are commonly prescribed as anti emetic drugs. In the present study a simple, rapid and sensitive RP-HPLC/UV method was developed for simultaneous determination of Domperidone and Itopride in pharmaceutical samples and human plasma, using Tenofavir as internal standard. Experimental conditions were optimized and method was validated according to the standard guidelines. Combination of water (pH 3.0) and acetonitrile (65:35 v/v) was used as mobile phase, pumped at the flow rate of 1.5 ml/min. Detector wavelength was set at 210 nm and column oven temperature was 40oC. Unlike conventional liquid-liquid extraction, simple precipitation technique was applied for drug extraction from human plasma using acetonitrile for deprotienation. The method showed adequate separation of both the analytes and best resolution was achieved using Hypersil BDS C8 column (150 mm × 4.6 mm, 5 μm). The method was quite linear in the range of 20-600 ng/ml. Recovery of the method was 92.31% and 89.82% for Domperidone and Itopride, respectively. Retention time of both the analytes and internal standard was below 15 min. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) for Domperidone were 5 and 10 ng/ml while for Itopride was 12 and 15 ng/ml, respectively. The developed method was successfully applied for in-vivo analysis of fast dispersible tablets of Domperidone in healthy human volunteer. The proposed method was a part of formulation development study and was efficiently applied for determination of the two drugs in various pharmaceutical products and human plasma. Copyright © 2015 Elsevier B.V. All rights reserved.
Oplatowska, Michalina; Stevenson, Paul J; Schulz, Claudia; Hartig, Lutz; Elliott, Christopher T
2011-09-01
Sudan dyes have been found to be added to chilli and chilli products for illegal colour enhancement purposes. Due to the possible carcinogenic effect, they are not authorized to be used in food in the European Union or the USA. However, over the last few years, many products imported from Asian and African countries have been reported via the Rapid Alert System for Food and Feed in the European Union to be contaminated with these dyes. In order to provide fast screening method for the detection of Sudan I (SI), which is the most widely abused member of Sudan dyes family, a unique (20 min without sample preparation) direct disequilibrium enzyme-linked immunosorbent assay (ELISA) was developed. The assay was based on polyclonal antibodies highly specific to SI. A novel, simple gel permeation chromatography clean-up method was developed to purify extracts from matrices containing high amounts of fat and natural pigments, without the need for a large dilution of the sample. The assay was validated according to the Commission Decision 2002/657/EC criteria. The detection capability was determined to be 15 ng g(-1) in sauces and 50 ng g(-1) in spices. The recoveries found ranged from 81% to 116% and inter- and intra-assay coefficients of variation from 6% to 20%. The assay was used to screen a range of products (85 samples) collected from different retail sources within and outside the European Union. Three samples were found to contain high amounts (1,649, 722 and 1,461 ng g(-1)) of SI by ELISA. These results were confirmed by liquid chromatography-tandem mass spectrometry method. The innovative procedure allows for the fast, sensitive and high throughput screening of different foodstuffs for the presence of the illegal colorant SI.
Integrated Multiscale Modeling of Molecular Computing Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregory Beylkin
2012-03-23
Significant advances were made on all objectives of the research program. We have developed fast multiresolution methods for performing electronic structure calculations with emphasis on constructing efficient representations of functions and operators. We extended our approach to problems of scattering in solids, i.e. constructing fast algorithms for computing above the Fermi energy level. Part of the work was done in collaboration with Robert Harrison and George Fann at ORNL. Specific results (in part supported by this grant) are listed here and are described in greater detail. (1) We have implemented a fast algorithm to apply the Green's function for themore » free space (oscillatory) Helmholtz kernel. The algorithm maintains its speed and accuracy when the kernel is applied to functions with singularities. (2) We have developed a fast algorithm for applying periodic and quasi-periodic, oscillatory Green's functions and those with boundary conditions on simple domains. Importantly, the algorithm maintains its speed and accuracy when applied to functions with singularities. (3) We have developed a fast algorithm for obtaining and applying multiresolution representations of periodic and quasi-periodic Green's functions and Green's functions with boundary conditions on simple domains. (4) We have implemented modifications to improve the speed of adaptive multiresolution algorithms for applying operators which are represented via a Gaussian expansion. (5) We have constructed new nearly optimal quadratures for the sphere that are invariant under the icosahedral rotation group. (6) We obtained new results on approximation of functions by exponential sums and/or rational functions, one of the key methods that allows us to construct separated representations for Green's functions. (7) We developed a new fast and accurate reduction algorithm for obtaining optimal approximation of functions by exponential sums and/or their rational representations.« less
Detection sensitivities in 3-8 MeV neutron activation
NASA Technical Reports Server (NTRS)
Wahlgren, M. A.; Wing, J.
1968-01-01
Study of detection sensitivities of 73 radioactive elements using fast unmoderated neutrons includes experiments for irradiation, cooling and counting conditions. The gamma ray emission spectra is used to identify the unknown material.
Intelligent Mobile Autonomous System
1987-01-01
used intermittently , and each of them characterizes the level of generalization. One cannot discern any another point within the tile, this is a...traversability space is not fast enough to be considered for actual control application. Alternatives to limit the computation time include (1) increasing the...error. (b) It must be concise and easy to "compute". In other words there must exist simple, fast procedures for instandating the "words" or "sentences
High performance pipelined multiplier with fast carry-save adder
NASA Technical Reports Server (NTRS)
Wu, Angus
1990-01-01
A high-performance pipelined multiplier is described. Its high performance results from the fast carry-save adder basic cell which has a simple structure and is suitable for the Gate Forest semi-custom environment. The carry-save adder computes the sum and carry within two gate delay. Results show that the proposed adder can operate at 200 MHz for a 2-micron CMOS process; better performance is expected in a Gate Forest realization.
Fast temporal correlation between hard X-ray and ultraviolet continuum brightenings
NASA Technical Reports Server (NTRS)
Machado, Marcos E.; Mauas, Pablo J.
1986-01-01
Recent Solar Maximum Mission (SMM) observations have shown fast and simultaneous increases in hard X-rays (HXR, E25 keV) and ultraviolet continuum (UVC, lambda lambda approx. equals 1600 and 1388 A) radiation. A simple and natural explanation is given for this phenomenon to happen, which does not involve extreme conditions for energy transport processes, and confirms earlier results on the effect of XUV photoionization in the solar atmosphere.
Rakesh Minocha; Walter C. Shortle
1993-01-01
Two simple and fast methods for the extraction of major inorganic cations (Ca, Mg, Mn, K) from small quantities of stemwood and needles of woody plants were developed. A 3.2- or 6.4-mm cobalt drill bit was used to shave samples from disks and increment cores of stemwood. For ion extraction, wood (ground or shavings) or needles were either homogenzied using a Tekmar...
HPGe detector shielding optimization with MCNPX for the MEDINA PGNAA cell
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicol, T.; Perot, B.; Carasco, C.
2015-07-01
Radioactive waste repositories must guarantee the non-toxicity of the waste in the long term, not only regarding radioactivity but also regarding other environmental contamination such as toxic chemicals. Analytical methods already exist for chemical characterization (ICP-MS, ICP-AES...) but they are based on test sampling. A possible alternative, for waste packages with an appropriate gamma radiation level, is to use Prompt Gamma Neutron Activation Analysis (PGNAA), a non-destructive measurement technique sensitive to several toxic chemicals. In view of the characterization of radioactive wastes in Germany and France, collaboration between the CEA Cadarache (France) and the Forschungszentrum Juelich (Germany) was initiated amore » few years ago. FZJ holds a PGNAA graphite cell called MEDINA (Multi Element Detection based on Instrumental Neutron Activation), allowing the characterization of 225 L drums. Fast neutrons are emitted from a D-T pulsed 14 MeV neutron generator and thermalized in graphite to induced radiative captures in the waste materials. Prompt capture gamma rays are detected using a 104% relative efficiency n-type HPGe. However, HPGe crystal is sensitive to fast neutron damage and to thermal neutron activation. A thermal neutron shield made of lithium fluorine and lithium carbonate is already used around the detector. In order to further decrease the current of fast and thermal neutrons coming into the crystal without penalizing MEDINA sensitivity (by decreasing the thermal neutron flux and neutron die away time of the cell, the gamma detection efficiency, or increasing the gamma background), some configurations based on easy-to-implement modifications of MEDINA have been simulated with MCNPX with a model of the cell already validated by experiments. Results show that fast and thermal neutron incoming current in the HPGe could easily be reduced by about a factor of 2 by additional quantities of graphite and by replacing lithium carbonate by lithium fluorine with a higher {sup 6}Li concentration. In addition, these modifications slightly increase the thermal neutron flux in the cell without deteriorating the neutron die away time, and reduce the gamma background about a factor of 2 during the neutron pulse but 5 times less after it. More important changes have also been tested, such as the addition of polyethylene and lead between the neutron generator and the HPGe detector, which is more effective regarding neutron shielding but decreases the neutron die away time, partly compensated by a larger initial thermal neutron flux. Concerning gamma background, hydrogen capture gamma ray (2.23 MeV) is increased due to the presence of polyethylene but lead around the HPGe decreases the total gamma background. In conclusion, simple modifications are possible to improve detector shielding and life time before thermal annealing of the crystal, without reducing MEDINA cell performances. Some of these modifications will be tested in the coming months. (authors)« less
Microplate freeze-dried cyanobacterial bioassay for fresh-waters environmental monitoring.
Martín-Betancor, Keila; Durand, Marie-José; Thouand, Gérald; Leganés, Francisco; Fernández-Piñas, Francisca; Rodea-Palomares, Ismael
2017-12-01
Microorganisms have been very useful in environmental monitoring due to their constant sensing of the surrounding environment, their easy maintenance and low cost. Some freeze-dried toxicity kits based on naturally bioluminescent bacteria are commercially available and commonly used to assess the toxicity of environmental samples such as Microtox (Aliivibrio fischeri) or ToxScreen (Photobacterium leiognathi), however, due to the marine origin of these bacteria, they could not be the most appropriate for fresh-waters monitoring. Cyanobacteria are one of the most representative microorganisms of aquatic environments, and are well suited for detecting contaminants in aqueous samples. This study presents the development and application of the first freeze-dried cyanobacterial bioassay for fresh-water contaminants detection. The effects of different cell growth phases, cryoprotectant solutions, freezing protocols, rehydration solutions and incubation conditions methods were evaluated and the best combination of these parameters for freeze-drying was selected. The study includes detailed characterization of sensitivity towards reference pollutants, as well as, comparison with the standard assays. Moreover, long-term viability and sensitivity were evaluated after 3 years of storage. Freeze-dried cyanobacteria showed, in general, higher sensitivity than the standard assays and viability of the cells remained after 3 years of storage. Finally, the validation of the bioassay using a wastewater sample was also evaluated. Freeze-drying of cyanobacteria in 96-well plates presents a simple, fast and multi-assay method for environmental monitoring. Copyright © 2017 Elsevier Ltd. All rights reserved.
Xie, Lingling; Xu, Yuandong; Cao, Xiaoyu
2013-07-01
In this work, a highly sensitive hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) at Au nanoparticles (AuNPs)/flower-like zinc oxide/graphene (AuNPs/ZnO/Gr) composite modified glassy carbon electrode (GCE) was constructed, where ZnO and Au nanoparticles were modified through layer-by-layer onto Gr/GCE. Flower-like ZnO nanoparticles could be easily prepared by adding ethanol to the precursor solution having higher concentration of hydroxide ions. The Hb/AuNPs/ZnO/Gr composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E(0)) of -0.367 V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.3 s(-1). The developed biosensor showed a very fast response (<2 s) toward H2O2 with good sensitivity, wide linear range, and low detection limit of 0.8 μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of Gr, and good biocompatibility of ZnO and AuNPs. The fabrication method of this biosensor was simple and effective for determination of H2O2 in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery. Copyright © 2013 Elsevier B.V. All rights reserved.
Nagababu, Enika; Rifkind, Joseph M.
2009-01-01
Recent studies have demonstrated that plasma nitrite (NO2-) reflects endothelial nitric oxide synthase activity and it has been proposed as a prognostic marker for cardiovascular disease. In addition, NO2- itself has been shown to have biological activities thought to be triggered by reduction back to NO in blood and tissues. The development of sensitive and reproducible methods for the quantitative determination of plasma NO2- is, therefore, of great importance. Ozone-based chemiluminescence assays have been shown to be highly sensitive for the determination of nanomolar quantities of NO and NO related species in biological fluids. We report here an improved direct chemiluminescence method for the determination of plasma NO2- without interference of other nitric oxide related species such as nitrate, S-nitrosothiols, N-nitrosamines, nitrated proteins and nitrated lipids. The method involves a reaction system consisting of glacial acetic acid and ascorbic acid in the purge vessel of the NO analyzer. Under these acidic conditions NO2- is stoichiometrically reduced to NO by ascorbic acid. Fasting human plasma NO2- values were found in the range of 56-210 nM (mean =110 ± 36 nM). This method has high sensitivity with an accuracy of 97% and high precision (C.V <10%) for determination of plasma nitrite. The present method is simple and highly specific for plasma NO2-. It is particularly suited to evaluate vasculature endothelial NO production that predicts the risks for cardiovascular disease. PMID:17382196
Sorouri, Rahim; Bagheri, Hasan; Afkhami, Abbas; Salimian, Jafar
2017-05-09
In this work, a novel nanocomposite consisting of electrosynthesized gold nanodendrites and chitosan nanoparticles (AuNDs/CSNPs) has been prepared to fabricate an impedimetric immunosensor based on a screen printed carbon electrode (SPCE) for the rapid and sensitive immunoassay of botulinum neurotoxin A (BoNT/A). BoNT/A polyclonal antibody was immobilized on the nanocomposite-modified SPCE for the signal amplification. The structure of the prepared nanocomposite was investigated by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The charge transfer resistance (R CT ) changes were used to detect BoNT/A as the specific immuno-interactions at the immunosensor surface that efficiently limited the electron transfer of Fe(CN)₆ 3-/4- as a redox probe at pH = 7.4. A linear relationship was observed between the %∆ R CT and the concentration logarithm of BoNT/A within the range of 0.2 to 230 pg·mL -1 with a detection limit (S/N = 3) of 0.15 pg·mL -1 . The practical applicability of the proposed sensor was examined by evaluating the detection of BoNT/A in milk and serum samples with satisfactory recoveries. Therefore, the prepared immunosensor holds great promise for the fast, simple and sensitive detection of BoNT/A in various real samples.
Sorouri, Rahim; Bagheri, Hasan; Afkhami, Abbas; Salimian, Jafar
2017-01-01
In this work, a novel nanocomposite consisting of electrosynthesized gold nanodendrites and chitosan nanoparticles (AuNDs/CSNPs) has been prepared to fabricate an impedimetric immunosensor based on a screen printed carbon electrode (SPCE) for the rapid and sensitive immunoassay of botulinum neurotoxin A (BoNT/A). BoNT/A polyclonal antibody was immobilized on the nanocomposite-modified SPCE for the signal amplification. The structure of the prepared nanocomposite was investigated by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The charge transfer resistance (RCT) changes were used to detect BoNT/A as the specific immuno-interactions at the immunosensor surface that efficiently limited the electron transfer of Fe(CN)63−/4− as a redox probe at pH = 7.4. A linear relationship was observed between the %∆RCT and the concentration logarithm of BoNT/A within the range of 0.2 to 230 pg·mL−1 with a detection limit (S/N = 3) of 0.15 pg·mL−1. The practical applicability of the proposed sensor was examined by evaluating the detection of BoNT/A in milk and serum samples with satisfactory recoveries. Therefore, the prepared immunosensor holds great promise for the fast, simple and sensitive detection of BoNT/A in various real samples. PMID:28486408