A Simple BODIPY-Based Viscosity Probe for Imaging of Cellular Viscosity in Live Cells
Su, Dongdong; Teoh, Chai Lean; Gao, Nengyue; Xu, Qing-Hua; Chang, Young-Tae
2016-01-01
Intracellular viscosity is a fundamental physical parameter that indicates the functioning of cells. In this work, we developed a simple boron-dipyrromethene (BODIPY)-based probe, BTV, for cellular mitochondria viscosity imaging by coupling a simple BODIPY rotor with a mitochondria-targeting unit. The BTV exhibited a significant fluorescence intensity enhancement of more than 100-fold as the solvent viscosity increased. Also, the probe showed a direct linear relationship between the fluorescence lifetime and the media viscosity, which makes it possible to trace the change of the medium viscosity. Furthermore, it was demonstrated that BTV could achieve practical applicability in the monitoring of mitochondrial viscosity changes in live cells through fluorescence lifetime imaging microscopy (FLIM). PMID:27589762
A Simple BODIPY-Based Viscosity Probe for Imaging of Cellular Viscosity in Live Cells.
Su, Dongdong; Teoh, Chai Lean; Gao, Nengyue; Xu, Qing-Hua; Chang, Young-Tae
2016-08-31
Intracellular viscosity is a fundamental physical parameter that indicates the functioning of cells. In this work, we developed a simple boron-dipyrromethene (BODIPY)-based probe, BTV, for cellular mitochondria viscosity imaging by coupling a simple BODIPY rotor with a mitochondria-targeting unit. The BTV exhibited a significant fluorescence intensity enhancement of more than 100-fold as the solvent viscosity increased. Also, the probe showed a direct linear relationship between the fluorescence lifetime and the media viscosity, which makes it possible to trace the change of the medium viscosity. Furthermore, it was demonstrated that BTV could achieve practical applicability in the monitoring of mitochondrial viscosity changes in live cells through fluorescence lifetime imaging microscopy (FLIM).
CdTe quantum dot as a fluorescence probe for vitamin B12 in dosage form
NASA Astrophysics Data System (ADS)
Vaishnavi, E.; Renganathan, R.
2013-11-01
We here report the CdTe quantum dot (CdTe QDs)-based sensor for probing vitamin B12 derivatives in aqueous solution. In this paper, simple and sensitive fluorescence quenching measurements has been employed. The Stern-Volmer constant (KSV), quenching rate constant (kq) and binding constant (K) were rationalized from fluorescence quenching measurement. Furthermore, the fluorescence resonance energy transfer (FRET) mechanism was discussed. This method was applicable over the concentration ranging from 1 to 14 μg/mL (VB12) with correlation coefficient of 0.993. The limit of detection (LOD) of VB12 was found to be 0.15 μg/mL. Moreover, the present approach opens a simple pathway for developing cost-effective, sensitive and selective QD-based fluorescence sensors/probes for biologically significant VB12 in pharmaceutical sample with mean recoveries in the range of 100-102.1%.
CdTe quantum dot as a fluorescence probe for vitamin B(12) in dosage form.
Vaishnavi, E; Renganathan, R
2013-11-01
We here report the CdTe quantum dot (CdTe QDs)-based sensor for probing vitamin B12 derivatives in aqueous solution. In this paper, simple and sensitive fluorescence quenching measurements has been employed. The Stern-Volmer constant (KSV), quenching rate constant (kq) and binding constant (K) were rationalized from fluorescence quenching measurement. Furthermore, the fluorescence resonance energy transfer (FRET) mechanism was discussed. This method was applicable over the concentration ranging from 1 to 14μg/mL (VB12) with correlation coefficient of 0.993. The limit of detection (LOD) of VB12 was found to be 0.15μg/mL. Moreover, the present approach opens a simple pathway for developing cost-effective, sensitive and selective QD-based fluorescence sensors/probes for biologically significant VB12 in pharmaceutical sample with mean recoveries in the range of 100-102.1%. Copyright © 2013 Elsevier B.V. All rights reserved.
A facile fluorescent "turn-off" method for sensing paraquat based on pyranine-paraquat interaction
NASA Astrophysics Data System (ADS)
Zhao, Zuzhi; Zhang, Fengwei; Zhang, Zipin
2018-06-01
Development of a technically simple yet effective method for paraquat (PQ) detection is of great importance due to its high clinical and environmental relevance. In this study, we developed a pyranine-based fluorescent "turn-off" method for PQ sensing based on pyranine-PQ interaction. We investigated the dependence of analytical performance of this method on the experimental conditions, such as the ion strength, medium pH, and so on. Under the optimized conditions, the method is sensitive and selective, and could be used for PQ detection in real-world sample. This study essentially provides a readily accessible fluorescent system for PQ sensing which is cheap, robust, and technically simple, and it is envisaged to find more interesting clinical and environmental applications.
Lu, Hongzhi; Quan, Shuai; Xu, Shoufang
2017-11-08
In this work, we developed a simple and sensitive ratiometric fluorescent assay for sensing trinitrotoluene (TNT) based on the inner filter effect (IFE) between gold nanoparticles (AuNPs) and ratiometric fluorescent nanoparticles (RFNs), which was designed by hybridizing green emissive carbon dots (CDs) and red emissive quantum dots (QDs) into a silica sphere as a fluorophore pair. AuNPs in their dispersion state can be a powerful absorber to quench CDs, while the aggregated AuNPs can quench QDs in the IFE-based fluorescent assays as a result of complementary overlap between the absorption spectrum of AuNPs and emission spectrum of RFNs. As a result of the fact that TNT can induce the aggregation of AuNPs, with the addition of TNT, the fluorescent of QDs can be quenched, while the fluorescent of CDs would be recovered. Then, ratiometric fluorescent detection of TNT is feasible. The present IFE-based ratiometric fluorescent sensor can detect TNT ranging from 0.1 to 270 nM, with a detection limit of 0.029 nM. In addition, the developed method was successfully applied to investigate TNT in water and soil samples with satisfactory recoveries ranging from 95 to 103%, with precision below 4.5%. The simple sensing approach proposed here could improve the sensitivity of colorimetric analysis by changing the ultraviolet analysis to ratiometric fluorescent analysis and promote the development of a dual-mode detection system.
NASA Astrophysics Data System (ADS)
Sabale, Pramod M.; George, Jerrin Thomas; Srivatsan, Seergazhi G.
2014-08-01
Given the biological and therapeutic significance of telomeres and other G-quadruplex forming sequences in human genome, it is highly desirable to develop simple methods to study these structures, which can also be implemented in screening formats for the discovery of G-quadruplex binders. The majority of telomere detection methods developed so far are laborious and use elaborate assay and instrumental setups, and hence, are not amenable to discovery platforms. Here, we describe the development of a simple homogeneous fluorescence turn-on method, which uses a unique combination of an environment-sensitive fluorescent nucleobase analogue, the superior base pairing property of PNA, and DNA-binding and fluorescence quenching properties of graphene oxide, to detect human telomeric DNA repeats of varying lengths. Our results demonstrate that this method, which does not involve a rigorous assay setup, would provide new opportunities to study G-quadruplex structures.Given the biological and therapeutic significance of telomeres and other G-quadruplex forming sequences in human genome, it is highly desirable to develop simple methods to study these structures, which can also be implemented in screening formats for the discovery of G-quadruplex binders. The majority of telomere detection methods developed so far are laborious and use elaborate assay and instrumental setups, and hence, are not amenable to discovery platforms. Here, we describe the development of a simple homogeneous fluorescence turn-on method, which uses a unique combination of an environment-sensitive fluorescent nucleobase analogue, the superior base pairing property of PNA, and DNA-binding and fluorescence quenching properties of graphene oxide, to detect human telomeric DNA repeats of varying lengths. Our results demonstrate that this method, which does not involve a rigorous assay setup, would provide new opportunities to study G-quadruplex structures. Electronic supplementary information (ESI) available. Figures, tables, experimental procedures and NMR spectra. See DOI: 10.1039/c4nr00878b
A FLUORESCENCE BASED ASSAY FOR DNA DAMAGE INDUCED BY STYRENE OXIDE
A rapid and simple assay to detect DNA damage to calf thymus DNA caused by styrene oxide (SO) is reported. This assay is based on changes observed in the melting and annealing behavior of the damaged DNA. The melting annealing process was monitored using a fluorescence indicat...
A FLUORESCENCE BASED ASSAY FOR DNA DAMAGE INDUCED BY RADIATION, CHEMICAL MUTAGENS AND ENZYMES
A simple and rapid assay to detect DNA damage is reported. This novel assay is based on changes in melting/annealing behavior and facilitated using certain dyes that increase their fluorescence upon association with double stranded (ds)DNA. Damage caused by ultraviolet (UV) ra...
NASA Astrophysics Data System (ADS)
Mahajan, Prasad G.; Dige, Nilam C.; Desai, Netaji K.; Patil, Shivajirao R.; Kondalkar, Vijay V.; Hong, Seong-Karp; Lee, Ki Hwan
2018-06-01
Nowadays scientist over the world are engaging to put forth improved methods to detect metal ion in an aqueous medium based on fluorescence studies. A simple, selective and sensitive method was proposed for detection of Co2+ ion using fluorescent organic nanoparticles. We synthesized a fluorescent small molecule viz. 4,4‧-{benzene-1,4-diylbis-[(Z)methylylidenenitrilo]}dibenzoic acid (BMBA) to explore its suitability as sensor for Co2+ ion and biocompatibility in form of nanoparticles. Fluorescence nanoparticles (BMBANPs) prepared by simple reprecipitation method. Aggregation induced enhanced emission of BMBANPs exhibits the narrower particle size of 68 nm and sphere shape morphology. The selective fluorescence quenching was observed by addition of Co2+ and does not affected by presence of other coexisting ion solutions. The photo-physical properties, viz. UV-absorption, fluorescence emission, and lifetime measurements are in support of ligand-metal interaction followed by static fluorescence quenching phenomenon in emission of BMBANPs. Finally, we develop a simple analytical method for selective and sensitive determination of Co2+ ion in environmental samples. The cell culture E. coli, Bacillus sps., and M. tuberculosis H37RV strain in the vicinity of BMBANPs indicates virtuous anti-bacterial and anti-tuberculosis activity which is of additional novel application shown by prepared nanoparticles.
Fan, Daoqing; Shang, Changshuai; Gu, Wenling; Wang, Erkang; Dong, Shaojun
2017-08-09
Glutathione (GSH) plays crucial roles in various biological functions, the level alterations of which have been linked to varieties of diseases. Herein, we for the first time expanded the application of oxidase-like property of MnO 2 nanosheet (MnO 2 NS) to fluorescent substrates of peroxidase. Different from previously reported fluorescent quenching phenomena, we found that MnO 2 NS could not only largely quench the fluorescence of highly fluorescent Scopoletin (SC) but also surprisingly enhance that of nonfluorescent Amplex Red (AR) via oxidation reaction. If MnO 2 NS is premixed with GSH, it will be reduced to Mn 2+ and lose the oxidase-like property, accompanied by subsequent increase in SC's fluorescence and decrease in AR's. On the basis of the above mechanism, we construct the first MnO 2 NS-based ratiometric fluorescent sensor for ultrasensitive and selective detection of GSH. Notably, this ratiometric sensor is programmed by the cascade logic circuit (an INHIBIT gate cascade with a 1 to 2 decoder). And a linear relationship between ratiometric fluorescent intensities of the two substrates and logarithmic values of GSH's concentrations is obtained. The detection limit of GSH is as low as 6.7 nM, which is much lower than previous ratiometric fluorescent sensors, and the lowest MnO 2 NS-based fluorescent GSH sensor reported so far. Furthermore, this sensor is simple, label-free, and low-cost; it also presents excellent applicability in human serum samples.
NASA Astrophysics Data System (ADS)
Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan
2018-04-01
A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.
NASA Astrophysics Data System (ADS)
Song, Seok-Jeong; Kim, Tae-Il; Kim, Youngmi; Nam, Hyoungsik
2018-05-01
Recently, a simple, sensitive, and low-cost fluorescent indicator has been proposed to determine water contents in organic solvents, drugs, and foodstuffs. The change of water content leads to the change of the indicator's fluorescence color under the ultra-violet (UV) light. Whereas the water content values could be estimated from the spectrum obtained by a bulky and expensive spectrometer in the previous research, this paper demonstrates a simple and low-cost camera-based water content measurement scheme with the same fluorescent water indicator. Water content is calculated over the range of 0-30% by quadratic polynomial regression models with color information extracted from the captured images of samples. Especially, several color spaces such as RGB, xyY, L∗a∗b∗, u‧v‧, HSV, and YCBCR have been investigated to establish the optimal color information features over both linear and nonlinear RGB data given by a camera before and after gamma correction. In the end, a 2nd order polynomial regression model along with HSV in a linear domain achieves the minimum mean square error of 1.06% for a 3-fold cross validation method. Additionally, the resultant water content estimation model is implemented and evaluated in an off-the-shelf Android-based smartphone.
Zhao, Yao-Peng; Zhao, Chun-Chang; Wu, Li-Zhu; Zhang, Li-Ping; Tung, Chen-Ho; Pan, Yuan-Jiang
2006-03-03
A simple, highly selective, neutral, fluorescent sensor for fluoride anions is reported. It is based on 2-ureido-4[1H]-pyrimidinone quadruple hydrogen-bonded AADD supramolecular assembly, and its assembling and disassembling processes are also able to respond to external stimuli reversibly.
Li, Zhen; Zhu, Wenping; Zhang, Jinwen; Jiang, Jianhui; Shen, Guoli; Yu, Ruqin
2013-07-07
A label-free fluorescent DNA biosensor has been presented based on isothermal circular strand-displacement polymerization reaction (ICSDPR) combined with graphene oxide (GO) binding. The proposed method is simple and cost-effective with a low detection limit of 4 pM, which compares favorably with other GO-based homogenous DNA detection methods.
2016-01-01
Reduced susceptibility to antimicrobials in Gram-negative bacteria may result from multiple resistance mechanisms, including increased efflux pump activity or reduced porin protein expression. Up-regulation of the efflux pump system is closely associated with multidrug resistance (MDR). To help investigate the role of efflux pumps on compound accumulation, a fluorescence-based assay was developed using fluorescent derivatives of trimethoprim (TMP), a broad-spectrum synthetic antibiotic that inhibits an intracellular target, dihydrofolate reductase (DHFR). Novel fluorescent TMP probes inhibited eDHFR activity with comparable potency to TMP, but did not kill or inhibit growth of wild type Escherichia coli. However, bactericidal activity was observed against an efflux pump deficient E. coli mutant strain (ΔtolC). A simple and quick fluorescence assay was developed to measure cellular accumulation of the TMP probe using either fluorescence spectroscopy or flow cytometry, with validation by LC-MS/MS. This fluorescence assay may provide a simple method to assess efflux pump activity with standard laboratory equipment. PMID:27737551
Simple and robust image-based autofocusing for digital microscopy.
Yazdanfar, Siavash; Kenny, Kevin B; Tasimi, Krenar; Corwin, Alex D; Dixon, Elizabeth L; Filkins, Robert J
2008-06-09
A simple image-based autofocusing scheme for digital microscopy is demonstrated that uses as few as two intermediate images to bring the sample into focus. The algorithm is adapted to a commercial inverted microscope and used to automate brightfield and fluorescence imaging of histopathology tissue sections.
Peng, Sijia; Wang, Wenjuan; Chen, Chunlai
2018-05-10
Fluorescence correlation spectroscopy is a powerful single-molecule tool that is able to capture kinetic processes occurring at the nanosecond time scale. However, the upper limit of its time window is restricted by the dwell time of the molecule of interest in the confocal detection volume, which is usually around submilliseconds for a freely diffusing biomolecule. Here, we present a simple and easy-to-implement method, named surface transient binding-based fluorescence correlation spectroscopy (STB-FCS), which extends the upper limit of the time window to seconds. We further demonstrated that STB-FCS enables capture of both intramolecular and intermolecular kinetic processes whose time scales cross several orders of magnitude.
A synthesis of fluorescent starch based on carbon nanoparticles for fingerprints detection
NASA Astrophysics Data System (ADS)
Li, Hongren; Guo, Xingjia; Liu, Jun; Li, Feng
2016-10-01
A pyrolysis method for synthesizing carbon nanoparticles (CNPs) were developed by using malic acid and ammonium oxalate as raw materials. The incorporation of a minor amount of carbon nanoparticles into starch powder imparts remarkable color-tunability. Based on this phenomenon, an environment friendly fluorescent starch powder for detecting latent fingerprints in non-porous surfaces was prepared. The fingerprints on different non-porous surfaces developed with this powder showed very good fluorescent images under ultraviolet excitation. The method using fluorescent starch powder as fluorescent marks is simple, rapid and green. Experimental results illustrated the effectiveness of proposed methods, enabling its practical applications in forensic sciences.
Low cost charged-coupled device (CCD) based detectors for Shiga toxins activity analysis
USDA-ARS?s Scientific Manuscript database
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of foodborne pathogens and their toxins. We describe a simple and relatively low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemilumi...
ERIC Educational Resources Information Center
Ma, Xiaofeng; Sun, Rui; Cheng, Jinghui; Liu, Jiaoyan; Gou, Fei; Xiang, Haifeng; Zhou, Xiangge
2016-01-01
A laboratory experiment visually exploring two opposite basic principles of fluorescence of aggregation-caused quenching (ACQ) and aggregation-induced emission (AIE) is demonstrated. The students would prepared two salicylaldehyde-based Schiff bases through a simple one-pot condensation reaction of one equiv of 1,2-diamine with 2 equiv of…
USDA-ARS?s Scientific Manuscript database
Genetic diversity analysis, which refers to the elaboration of total extent of genetic characteristics in the genetic makeup of a certain species, constitutes a classical strategy for the study of diversity, population genetic structure, and breeding practices. In this study, fluorescence-labeled se...
Nakamura, Akinobu; Takigawa, Kazumasa; Kurishita, Yasutaka; Kuwata, Keiko; Ishida, Manabu; Shimoda, Yasushi; Hamachi, Itaru; Tsukiji, Shinya
2014-06-11
We report a general strategy to create small-molecule fluorescent probes for the nucleus in living cells. Our strategy is based on the attachment of the DNA-binding Hoechst compound to a fluorophore of interest. Using this approach, simple fluorescein, BODIPY, and rhodamine dyes were readily converted to novel turn-on fluorescent nucleus-imaging probes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng Yejun
2011-04-15
Ruby (Al{sub 2}O{sub 3}, with {approx}0.5 wt. % Cr doping) is one of the most widely used manometers at the giga-Pascal scale. Traditionally, its fluorescence is excited with intense laser sources. Here, I present a simple, robust, and portable design that employs light-emitting diodes (LEDs) instead. This LED-based system is safer in comparison with laser-based ones.
A simple rhodamine hydrazide-based turn-on fluorescent probe for HOCl detection.
Zhang, Zhen; Zou, Yuan; Deng, Chengquan; Meng, Liesu
2016-06-01
Hypochlorous acid (HOCl) plays a crucial role in daily life and mediates a variety of physiological processes, however, abnormal levels of HOCl have been associated with numerous human diseases. It is therefore of significant interest to establish a simple, selective, rapid and sensitive fluorogenic method for the detection of HOCl in environmental and biological samples. A hydrazide-containing fluorescent probe based on a rhodamine scaffold was facilely developed that could selectively detect HOCl over other biologically relevant reactive oxygen species, reactive nitrogen species and most common metal ions in vitro. Via an irreversible oxidation-hydrolysis mechanism, and upon HOCl-triggered opening of the intramolecular spirocyclic ring during detection, the rhodamine hydrazide-based probe exhibited large fluorescence enhancement in the emission spectra with a fast response, low detection limit and comparatively wide pH detection range in aqueous media. The probe was further successfully applied to monitoring trace HOCl in tap water and imaging both exogenous and endogenous HOCl within living cells. It is anticipated that this simple and useful probe might be an efficient tool with which to facilitate more HOCl-related chemical and biological research. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Fast and accurate image recognition algorithms for fresh produce food safety sensing
NASA Astrophysics Data System (ADS)
Yang, Chun-Chieh; Kim, Moon S.; Chao, Kuanglin; Kang, Sukwon; Lefcourt, Alan M.
2011-06-01
This research developed and evaluated the multispectral algorithms derived from hyperspectral line-scan fluorescence imaging under violet LED excitation for detection of fecal contamination on Golden Delicious apples. The algorithms utilized the fluorescence intensities at four wavebands, 680 nm, 684 nm, 720 nm, and 780 nm, for computation of simple functions for effective detection of contamination spots created on the apple surfaces using four concentrations of aqueous fecal dilutions. The algorithms detected more than 99% of the fecal spots. The effective detection of feces showed that a simple multispectral fluorescence imaging algorithm based on violet LED excitation may be appropriate to detect fecal contamination on fast-speed apple processing lines.
Ren, Fang; Takashima, Hideaki; Tanaka, Yoshito; Fujiwara, Hideki; Sasaki, Keiji
2013-11-18
A simple tapered fiber based photonic-plasmonic hybrid nanostructure composed of a thin tapered fiber and a pseudoisocyanine (PIC)-attached Au-coated tip was demonstrated. Using this simple hybrid nanostructure, we succeeded in observing two-photon excited fluorescence from the PIC dye molecules under a weak continuous wave excitation condition. From the results of the tip-fiber distance dependence and excitation polarization dependence, we found that using a thin tapered fiber and an Au-coated tip realized efficient coupling of the incident light (~95%) and LSP excitation at the Au-coated tip, suggesting the possibility of efficiently inducing two-photon excited fluorescence from the PIC dye molecules attached on the Au-coated tip. This simple photonic-plasmonic hybrid system is one of the promising tools for single photon sources, highly efficient plasmonic sensors, and integrated nonlinear plasmonic devices.
Ultra-small dye-doped silica nanoparticles via modified sol-gel technique.
Riccò, R; Nizzero, S; Penna, E; Meneghello, A; Cretaio, E; Enrichi, F
2018-01-01
In modern biosensing and imaging, fluorescence-based methods constitute the most diffused approach to achieve optimal detection of analytes, both in solution and on the single-particle level. Despite the huge progresses made in recent decades in the development of plasmonic biosensors and label-free sensing techniques, fluorescent molecules remain the most commonly used contrast agents to date for commercial imaging and detection methods. However, they exhibit low stability, can be difficult to functionalise, and often result in a low signal-to-noise ratio. Thus, embedding fluorescent probes into robust and bio-compatible materials, such as silica nanoparticles, can substantially enhance the detection limit and dramatically increase the sensitivity. In this work, ultra-small fluorescent silica nanoparticles (NPs) for optical biosensing applications were doped with a fluorescent dye, using simple water-based sol-gel approaches based on the classical Stöber procedure. By systematically modulating reaction parameters, controllable size tuning of particle diameters as low as 10 nm was achieved. Particles morphology and optical response were evaluated showing a possible single-molecule behaviour, without employing microemulsion methods to achieve similar results. Graphical abstractWe report a simple, cheap, reliable protocol for the synthesis and systematic tuning of ultra-small (< 10 nm) dye-doped luminescent silica nanoparticles.
Chung, Kyeongwoon; Yang, Da Seul; Jung, Jaehun; Seo, Deokwon; Kwon, Min Sang; Kim, Jinsang
2016-10-06
Differentiation of solvents having similar physicochemical properties, such as ethanol and methanol, is an important issue of interest. However, without performing chemical analyses, discrimination between methanol and ethanol is highly challenging due to their similarity in chemical structure as well as properties. Here, we present a novel type of alcohol and water sensor based on the subtle differences in interaction among solvent analytes, fluorescent organic molecules, and a mesoporous silica gel substrate. A gradual change in the chemical structure of the fluorescent diketopyrrolopyrrole (DPP) derivatives alters their interaction with the substrate and solvent analyte, which creates a distinct intermolecular aggregation of the DPP derivatives on the silica gel substrate depending on the solvent environment and produces a change in the fluorescence color and intensity as a sensory signal. The devised sensor device, which is fabricated with simple drop-casting of the DPP derivative solutions onto a silica gel substrate, exhibited a completely reversible fluorescence signal change with large fluorescence signal contrast, which allows selective solvent detection by simple optical observation with the naked eye under UV light. Superior selectivity of the alcohol and water sensor system, which can clearly distinguish among ethanol, methanol, ethylene glycol, and water, is demonstrated.
NASA Astrophysics Data System (ADS)
Kwon, Yong-Su; Choi, Kee-Bong; Lim, Hyungjun; Lee, Sunghwi; Lee, Jae-Jong
2018-06-01
Simple and versatile methodologies have been reported that customize the surface of superparamagnetic iron oxide (SPIO) nanoparticles and impart additional fluorescence capabilities to these contrast agents. Herein, we present the rational design, synthesis, characterization, and biological applications of a new magnetic-based fluorescent probe. The dual modality imaging protocol was developed by labeling fluorophore with alginate natural polymers that have excellent biocompatibility and biodegradability, and using gelification method to form nanocomposites containing SPIO. The formation of alginate-based fluorescent magnetic (AFM) nanoparticles was observed in spherical and elliptical forms with a diameter of less than 500 nm by a transmission electron microscope (TEM). The fluorescent wavelength band in the range of 560 nm was also confirmed in the UV–visible spectrophotometer. In this study, we demonstrate that the multi-tasking design of AFM nanoparticles provides an ideal platform for building balanced dual-image probes of magnetic resonance imaging and optical imaging.
Shrink-induced silica multiscale structures for enhanced fluorescence from DNA microarrays.
Sharma, Himanshu; Wood, Jennifer B; Lin, Sophia; Corn, Robert M; Khine, Michelle
2014-09-23
We describe a manufacturable and scalable method for fabrication of multiscale wrinkled silica (SiO2) structures on shrink-wrap film to enhance fluorescence signals in DNA fluorescence microarrays. We are able to enhance the fluorescence signal of hybridized DNA by more than 120 fold relative to a planar glass slide. Notably, our substrate has improved detection sensitivity (280 pM) relative to planar glass slide (11 nM). Furthermore, this is accompanied by a 30-45 times improvement in the signal-to-noise ratio (SNR). Unlike metal enhanced fluorescence (MEF) based enhancements, this is a far-field and uniform effect based on surface concentration and photophysical effects from the nano- to microscale SiO2 structures. Notably, the photophysical effects contribute an almost 2.5 fold enhancement over the concentration effects alone. Therefore, this simple and robust method offers an efficient technique to enhance the detection capabilities of fluorescence based DNA microarrays.
Shrink-Induced Silica Multiscale Structures for Enhanced Fluorescence from DNA Microarrays
2015-01-01
We describe a manufacturable and scalable method for fabrication of multiscale wrinkled silica (SiO2) structures on shrink-wrap film to enhance fluorescence signals in DNA fluorescence microarrays. We are able to enhance the fluorescence signal of hybridized DNA by more than 120 fold relative to a planar glass slide. Notably, our substrate has improved detection sensitivity (280 pM) relative to planar glass slide (11 nM). Furthermore, this is accompanied by a 30–45 times improvement in the signal-to-noise ratio (SNR). Unlike metal enhanced fluorescence (MEF) based enhancements, this is a far-field and uniform effect based on surface concentration and photophysical effects from the nano- to microscale SiO2 structures. Notably, the photophysical effects contribute an almost 2.5 fold enhancement over the concentration effects alone. Therefore, this simple and robust method offers an efficient technique to enhance the detection capabilities of fluorescence based DNA microarrays. PMID:25191785
Wan, Qian; Zhuo, Ji-Bin; Wang, Xiao-Xue; Lin, Cai-Xia; Yuan, Yao-Feng
2015-03-28
A structurally simple, 2,2-diferrocenylpropane-based ion pair receptor 1 was synthesized and characterized by (1)H NMR, (13)C NMR, HRMS, elemental analyses, and single-crystal X-ray diffraction. The ion pair receptor 1 showed excellent selectivity and sensitivity towards Pb(2+) with multi-channel responses: a fluorescence enhancement (more than 42-fold), a notable color change from yellow to red, redox anodic shift (ΔE1/2 = 151 mV), while HSO4(-) promoted fluorescence enhancement when Pb(2+) or Zn(2+) was bonded to the cation binding-site. (1)H NMR titration and density functional theory were performed to reveal the sensing mechanism based on photo-induced electron transfer (PET).
Chao, Duobin; Ni, Shitan
2016-05-20
Great efforts have been made to develop fluorescent probes for pyrophosphate (PPi) detection. Nucleus staining with fluorescence microscopy has been also widely investigated. But fluorescent probes for PPi detection with high sensitivity in water medium and nucleus staining with low-cost non-precious metal complexes in living cells are still challenging. Herein, we report simple terpyridine-Zn(II) complexes for selective nanomolar PPi detection over ATP and ADP in water based on aggregation induced emission (AIE) and intramolecular charge transfer (ICT). In addition, these terpyridine-Zn(II) complexes were successfully employed for nucleus staining in living cells. These results demonstrated simply obtained terpyridine-Zn(II) complexes are powerful tool for PPi detection and the development of PPi-related studies.
Simple fluorescence-based high throughput cell viability assay for filamentous fungi.
Chadha, S; Kale, S P
2015-09-01
Filamentous fungi are important model organisms to understand the eukaryotic process and have been frequently exploited in research and industry. These fungi are also causative agents of serious diseases in plants and humans. Disease management strategies include in vitro susceptibility testing of the fungal pathogens to environmental conditions and antifungal agents. Conventional methods used for antifungal susceptibilities are cumbersome, time-consuming and are not suitable for a large-scale analysis. Here, we report a rapid, high throughput microplate-based fluorescence method for investigating the toxicity of antifungal and stress (osmotic, salt and oxidative) agents on Magnaporthe oryzae and compared it with agar dilution method. This bioassay is optimized for the resazurin reduction to fluorescent resorufin by the fungal hyphae. Resazurin bioassay showed inhibitory rates and IC50 values comparable to the agar dilution method and to previously reported IC50 or MICs for M. oryzae and other fungi. The present method can screen range of test agents from different chemical classes with different modes of action for antifungal activities in a simple, sensitive, time and cost effective manner. A simple fluorescence-based high throughput method is developed to test the effects of stress and antifungal agents on viability of filamentous fungus Magnaporthe oryzae. This resazurin fluorescence assay can detect inhibitory effects comparable to those obtained using the growth inhibition assay with added advantages of simplicity, time and cost effectiveness. This high throughput viability assay has a great potential in large-scale screening of the chemical libraries of antifungal agents, for evaluating the effects of environmental conditions and hyphal kinetic studies in mutant and natural populations of filamentous fungi. © 2015 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Maes, Thomas; Jessop, Rebecca; Wellner, Nikolaus; Haupt, Karsten; Mayes, Andrew G.
2017-03-01
A new approach is presented for analysis of microplastics in environmental samples, based on selective fluorescent staining using Nile Red (NR), followed by density-based extraction and filtration. The dye adsorbs onto plastic surfaces and renders them fluorescent when irradiated with blue light. Fluorescence emission is detected using simple photography through an orange filter. Image-analysis allows fluorescent particles to be identified and counted. Magnified images can be recorded and tiled to cover the whole filter area, allowing particles down to a few micrometres to be detected. The solvatochromic nature of Nile Red also offers the possibility of plastic categorisation based on surface polarity characteristics of identified particles. This article details the development of this staining method and its initial cross-validation by comparison with infrared (IR) microscopy. Microplastics of different sizes could be detected and counted in marine sediment samples. The fluorescence staining identified the same particles as those found by scanning a filter area with IR-microscopy.
Maes, Thomas; Jessop, Rebecca; Wellner, Nikolaus; Haupt, Karsten; Mayes, Andrew G.
2017-01-01
A new approach is presented for analysis of microplastics in environmental samples, based on selective fluorescent staining using Nile Red (NR), followed by density-based extraction and filtration. The dye adsorbs onto plastic surfaces and renders them fluorescent when irradiated with blue light. Fluorescence emission is detected using simple photography through an orange filter. Image-analysis allows fluorescent particles to be identified and counted. Magnified images can be recorded and tiled to cover the whole filter area, allowing particles down to a few micrometres to be detected. The solvatochromic nature of Nile Red also offers the possibility of plastic categorisation based on surface polarity characteristics of identified particles. This article details the development of this staining method and its initial cross-validation by comparison with infrared (IR) microscopy. Microplastics of different sizes could be detected and counted in marine sediment samples. The fluorescence staining identified the same particles as those found by scanning a filter area with IR-microscopy. PMID:28300146
NASA Astrophysics Data System (ADS)
Ortega-Martinez, Antonio; Padilla-Martinez, Juan Pablo; Franco, Walfre
2016-04-01
The skin contains several fluorescent molecules or fluorophores that serve as markers of structure, function and composition. UV fluorescence excitation photography is a simple and effective way to image specific intrinsic fluorophores, such as the one ascribed to tryptophan which emits at a wavelength of 345 nm upon excitation at 295 nm, and is a marker of cellular proliferation. Earlier, we built a clinical UV photography system to image cellular proliferation. In some samples, the naturally low intensity of the fluorescence can make it difficult to separate the fluorescence of cells in higher proliferation states from background fluorescence and other imaging artifacts -- like electronic noise. In this work, we describe a statistical image segmentation method to separate the fluorescence of interest. Statistical image segmentation is based on image averaging, background subtraction and pixel statistics. This method allows to better quantify the intensity and surface distributions of fluorescence, which in turn simplify the detection of borders. Using this method we delineated the borders of highly-proliferative skin conditions and diseases, in particular, allergic contact dermatitis, psoriatic lesions and basal cell carcinoma. Segmented images clearly define lesion borders. UV fluorescence excitation photography along with statistical image segmentation may serve as a quick and simple diagnostic tool for clinicians.
Chantada-Vázquez, María Pilar; Sánchez-González, Juan; Peña-Vázquez, Elena; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2016-03-01
A new molecularly imprinted polymer (MIP)-based fluorescent artificial receptor has been prepared by anchoring a selective MIP for cocaine (COC) on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). The prepared material combines the high selectivity attributed to MIPs and the sensitive fluorescent property of the Mn-doped ZnS QDs. Simple and low cost methods have therefore been optimized for assessing cocaine abuse in urine by monitoring the fluorescence quenching when the template (COC) and also metabolites from COC [benzoylecgonine (BZE) and ecgonine methyl ester (EME)] are present. Fluorescence quenching was not observed when performing experiments with other drugs of abuse (and their metabolites) or when using nonimprinted polymer (NIP)-coated QDs. Under optimized operating conditions (1.5 mL of 200 mg L(-1) MIP-coated QDs solution, pH 5.5, and 15 min before fluorescence scanning) two analytical methods were developed/validated. One of the procedures (direct method) consisted of urine sample 1:20 dilution before fluorescence measurements. The method has been found to be fast, precise, and accurate, but the standard addition technique for performing the analysis was required because of the existence of matrix effect. The second procedure performed a solid phase extraction (SPE) first, avoiding matrix effect and allowing external calibration. The limits of detection of the methods were 0.076 mg L(-1) (direct method) and 0.0042 mg L(-1) (SPE based method), which are lower than the cutoff values for confirmative conclusions regarding cocaine abuse.
NASA Astrophysics Data System (ADS)
Adams, Daniel L.; Alpaugh, R. Katherine; Tsai, Susan; Tang, Cha-Mei; Stefansson, Steingrimur
2016-09-01
In tissue biopsies formalin fixed paraffin embedded cancer blocks are micro-sectioned producing multiple semi-identical specimens which are analyzed and subtyped proteomically, and genomically, with numerous biomarkers. In blood based biopsies (BBBs), blood is purified for circulating tumor cells (CTCs) and clinical utility is typically limited to cell enumeration, as only 2-3 positive fluorescent markers and 1 negative marker can be used. As such, increasing the number of subtyping biomarkers on each individual CTC could dramatically enhance the clinical utility of BBBs, allowing in depth interrogation of clinically relevant CTCs. We describe a simple and inexpensive method for quenching the specific fluors of fluorescently stained CTCs followed by sequential restaining with additional biomarkers. As proof of principle a CTC panel, immunosuppression panel and stem cell panel were used to sequentially subtype individual fluorescently stained patient CTCs, suggesting a simple and universal technique to analyze multiple clinically applicable immunomarkers from BBBs.
Kalinina, Marina A; Skvortsov, Dmitry A; Rubtsova, Maria P; Komarova, Ekaterina S; Dontsova, Olga A
2018-06-01
High- and medium-throughput assays are now routine methods for drug screening and toxicology investigations on mammalian cells. However, a simple and cost-effective analysis of cytotoxicity that can be carried out with commonly used laboratory equipment is still required. The developed cytotoxicity assays are based on human cell lines stably expressing eGFP, tdTomato, mCherry, or Katushka2S fluorescent proteins. Red fluorescent proteins exhibit a higher signal-to-noise ratio, due to less interference by medium autofluorescence, in comparison to green fluorescent protein. Measurements have been performed on a fluorescence scanner, a plate fluorimeter, and a camera photodocumentation system. For a 96-well plate assay, the sensitivity per well and the measurement duration were 250 cells and 15 min for the scanner, 500 cells and 2 min for the plate fluorimeter, and 1000 cells and less than 1 min for the camera detection. These sensitivities are similar to commonly used MTT (tetrazolium dye) assays. The used scanner and the camera had not been previously applied for cytotoxicity evaluation. An image processing scheme for the high-resolution scanner is proposed that significantly diminishes the number of control wells, even for a library containing fluorescent substances. The suggested cytotoxicity assay has been verified by measurements of the cytotoxicity of several well-known cytotoxic drugs and further applied to test a set of novel bacteriotoxic compounds in a medium-throughput format. The fluorescent signal of living cells is detected without disturbing them and adding any reagents, thus allowing to investigate time-dependent cytotoxicity effects on the same sample of cells. A fast, simple and cost-effective assay is suggested for cytotoxicity evaluation based on mammalian cells expressing fluorescent proteins and commonly used laboratory equipment.
Enumerating viruses by using fluorescence and the nature of the nonviral background fraction.
Pollard, Peter C
2012-09-01
Bulk fluorescence measurements could be a faster and cheaper way of enumerating viruses than epifluorescence microscopy, flow cytometry, or transmission electron microscopy (TEM). However, since viruses are not imaged, the background fluorescence compromises the signal, and we know little about its nature. In this paper the size ranges of nucleotides that fluoresce in the presence of SYBR gold were determined for wastewater and a range of freshwater samples using a differential filtration method. Fluorescence excitation-emission matrices (FEEMs) showed that >70% of the SYBR fluorescence was in the <10-nm size fraction (background) and was not associated with intact viruses. This was confirmed using TEM. The use of FEEMs to develop a fluorescence-based method for counting viruses is an approach that is fundamentally different from the epifluorescence microscopy technique used for enumerating viruses. This high fluorescence background is currently overlooked, yet it has had a most pervasive influence on the development of a simple fluorescence-based method for quantifying viral abundance in water.
Fluorescence errors in integrating sphere measurements of remote phosphor type LED light sources
NASA Astrophysics Data System (ADS)
Keppens, A.; Zong, Y.; Podobedov, V. B.; Nadal, M. E.; Hanselaer, P.; Ohno, Y.
2011-05-01
The relative spectral radiant flux error caused by phosphor fluorescence during integrating sphere measurements is investigated both theoretically and experimentally. Integrating sphere and goniophotometer measurements are compared and used for model validation, while a case study provides additional clarification. Criteria for reducing fluorescence errors to a degree of negligibility as well as a fluorescence error correction method based on simple matrix algebra are presented. Only remote phosphor type LED light sources are studied because of their large phosphor surfaces and high application potential in general lighting.
NASA Astrophysics Data System (ADS)
Kalchenko, Vyacheslav; Molodij, Guillaume; Kuznetsov, Yuri; Smolyakov, Yuri; Israeli, David; Meglinski, Igor; Harmelin, Alon
2016-03-01
The use of fluorescence imaging of vascular permeability becomes a golden standard for assessing the inflammation process during experimental immune response in vivo. The use of the optical fluorescence imaging provides a very useful and simple tool to reach this purpose. The motivation comes from the necessity of a robust and simple quantification and data presentation of inflammation based on a vascular permeability. Changes of the fluorescent intensity, as a function of time is a widely accepted method to assess the vascular permeability during inflammation related to the immune response. In the present study we propose to bring a new dimension by applying a more sophisticated approach to the analysis of vascular reaction by using a quantitative analysis based on methods derived from astronomical observations, in particular by using a space-time Fourier filtering analysis followed by a polynomial orthogonal modes decomposition. We demonstrate that temporal evolution of the fluorescent intensity observed at certain pixels correlates quantitatively to the blood flow circulation at normal conditions. The approach allows to determine the regions of permeability and monitor both the fast kinetics related to the contrast material distribution in the circulatory system and slow kinetics associated with extravasation of the contrast material. Thus, we introduce a simple and convenient method for fast quantitative visualization of the leakage related to the inflammatory (immune) reaction in vivo.
NASA Astrophysics Data System (ADS)
Li, Huihui; Yang, Cailing; Zhu, Xinyue; Zhang, Haixia
2017-06-01
A simple ratiometric fluorescent sensor for fructose was presented. It consisted of 10-hydroxybenzo[h]quinoline (HBQ) which showed emission at 572 nm and 3-pyridylboronic acid (PDBA) whose complex with HBQ gave emission at 500 nm. The reaction of fructose with PDBA inhibited the complexation of HBQ with PDBA, resulting in the change of dual-emission intensity ratio. The sensor well quantified fructose in the range of 0.015-2.5 mM with detection limit of 0.005 mM. Besides, this sensor exhibited excellent selectivity and was successfully applied to fructose detection in food. This work provides a simple ratiometric sensing platform for sensitive and selective detection of fructose.
Pal, Kaushik; Mallick, Suman; Koner, Apurba L
2015-06-28
Host-guest complexation of dapoxyl sodium sulphonate (DSS), an intramolecular charge transfer dye with water-soluble and non-toxic macrocycle γ-cyclodextrin (γ-CD), has been investigated in a wide pH range. Steady-state absorption, fluorescence and time-resolved fluorescence measurements confirm the positioning of DSS into the hydrophobic cavity of γ-CD. A large fluorescence enhancement ca. 30 times, due to 1 : 2 complex formation and host-assisted guest-protonation have been utilised for developing a method for the utilisation of CD based drug-delivery applications. A simple fluorescence-displacement based approach is implemented at physiological pH for the assessment of binding strength of pharmaceutically useful small drug molecules (ibuprofen, paracetamol, methyl salicylate, salicylic acid, aspirin, and piroxicam) and six important antibiotic drugs (resazurin, thiamphenicol, chloramphenicol, ampicillin, kanamycin, and sorbic acid) with γ-CD.
Siegel, Nisan; Storrie, Brian; Bruce, Marc; Brooker, Gary
2015-02-07
FINCH holographic fluorescence microscopy creates high resolution super-resolved images with enhanced depth of focus. The simple addition of a real-time Nipkow disk confocal image scanner in a conjugate plane of this incoherent holographic system is shown to reduce the depth of focus, and the combination of both techniques provides a simple way to enhance the axial resolution of FINCH in a combined method called "CINCH". An important feature of the combined system allows for the simultaneous real-time image capture of widefield and holographic images or confocal and confocal holographic images for ready comparison of each method on the exact same field of view. Additional GPU based complex deconvolution processing of the images further enhances resolution.
Le, Tao; Zhang, Zhihao; Wu, Juan; Shi, Haixing; Cao, Xudong
2018-01-01
A rapid, simple, and sensitive fluorescent immunochromatographic strip test (ICST) based on quantum dots (QDs) has been developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. To achieve this, QD-labeled antibody conjugates, which consist of CdSe/ZnS QDs and monoclonal antibodies, were prepared by an activated ester method. Under optimal conditions, with the nitrophenyl derivative of AHD as the target, the ICST had a linear range from 0.1 to 100 ng/mL, with a correlation coefficient of 0.9656 and a 50% inhibitory concentration of 4.51 ng/mL. The limit of detection was 0.14 ng/g, which was below the minimum required performance limit of 1 μg/kg for AHD established by the European Commission. The recoveries for AHD ranged from 81.5% to 108.2%, with coefficients of variation below 13%, based on intraday and interday analysis. Furthermore, for AHD in real samples, the ICST showed high reliability and high correlation with liquid chromatography-tandem mass spectrometry (correlation coefficient of 0.9916). To the best of our knowledge, this is the first report of a novel and sensitive method based on a fluorescent ICST to detect AHD below the minimum required performance limit. The ICST demonstrated high reliability, and could be ideally suited for rapid, simple, and on-site screening of AHD contamination in animal tissues. Graphical abstract A rapid, simple, and sensitive fluorescent immunochromatographic strip test that is based on quantum dots was developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. 2-NBA 2-nitrobenzaldehyde, NP nitrophenyl.
Abney, Kristopher K; Ramos-Hunter, Susan J; Romaine, Ian M; Godwin, J Shawn; Sulikowski, Gary A; Weaver, Charles David
2018-04-21
This study reports the synthesis and testing of a family of rhodamine pro-fluorophores and an enzyme capable of converting pro-fluorophores to Rhodamine 110. We prepared a library of simple N,N'-diacyl rhodamines and investigated Porcine Liver Esterase (PLE) as an enzyme to activate rhodamine-based pro-fluorophores. A PLE-expressing cell line generated an increase in fluorescence rapidly upon pro-fluorophore addition demonstrating the rhodamine pro-fluorophores are readily taken up and fluorescent upon PLE-mediated release. Rhodamine pro-fluorophore amides trifluoroacetamide (TFAm) and proponamide (PAm) appeared to be the best substrates using a cell-based assay using PLE expressing HEK293. Our pro-fluorophore series showed diffusion into live cells and resisted endogenous hydrolysis. The use of our engineered cell line containing the exogenous enzyme PLE demonstrated the rigorousness of amide masking when compared to cells not containing PLE. This simple and selective pro-fluorophore rhodamine pair with PLE offers the potential to be used in vitro and in vivo fluorescence based assays. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Anazawa, Takashi; Uchiho, Yuichi; Yokoi, Takahide; Chalkidis, George; Yamazaki, Motohiro
2017-06-27
A five-color fluorescence-detection system for eight-channel plastic-microchip electrophoresis was developed. In the eight channels (with effective electrophoretic lengths of 10 cm), single-stranded DNA fragments were separated (with single-base resolution up to 300 bases within 10 min), and seventeen-loci STR genotyping for forensic human identification was successfully demonstrated. In the system, a side-entry laser beam is passed through the eight channels (eight A channels), with alternately arrayed seven sacrificial channels (seven B channels), by a technique called "side-entry laser-beam zigzag irradiation." Laser-induced fluorescence from the eight A channels and Raman-scattered light from the seven B channels are then simultaneously, uniformly, and spectroscopically detected, in the direction perpendicular to the channel array plane, through a transmission grating and a CCD camera. The system is therefore simple and highly sensitive. Because the microchip is fabricated by plastic-injection molding, it is inexpensive and disposable and thus suitable for actual use in various fields.
Yan, Jingjing; Huang, Xin; Liu, Shaopu; Yang, Jidong; Yuan, Yusheng; Duan, Ruilin; Zhang, Hui; Hu, Xiaoli
2016-01-01
A simple, rapid and effective method for auramine O (AO) detection was proposed by fluorescence and UV-Vis absorption spectroscopy. In the BR buffer system (pH 7.0), AO had a strong quenching ability to the fluorescence of bovin serum albumin (BSA) by dynamic quenching. In terms of the thermodynamic parameters calculated as ΔH > 0 and ΔS > 0, the resulting binding of BSA and AO was mainly attributed to the hydrophobic interaction forces. The linearity of this method was in the concentration range from 0.16 to 50 μmol L(-1) with a detection limit of 0.05 μmol L(-1). Based on fluorescence resonance energy transfer (FRET), the distance r (1.36 nm) between donor (BSA) and acceptor (AO) was obtained. Furthermore, the effects of foreign substances and ionic strength were evaluated under the optimum reaction conditions. BSA as a selective probe could be applied to the analysis of AO in medicines with satisfactory results.
NASA Astrophysics Data System (ADS)
Shen, Youming; Zhang, Xiangyang; Zhang, Chunxiang; Zhang, Youyu; Jin, Junling; Li, Haitao
2018-02-01
A simple benzothiazole fluorescent chemosensor was developed for the fast sequential detection of Cu2 + and biothiols through modulating the excited-state intramolecular proton transfer (ESIPT) process. The compound 1 exhibits highly selective and sensitive fluorescence ;on-off; recognition to Cu2 + with a 1:1 binding stoichiometry by ESIPT hinder. The in situ generated 1-Cu2 + complex can serve as an ;on-off; fluorescent probe for high selectivity toward biothiols via Cu2 + displacement approach, which exerts ESIPT recovery. It is worth pointing out that the 1-Cu2 + complex shows faster for cysteins (within 1 min) than other biothiols such as homocysteine (25 min) and glutathione (25 min). Moreover, the compound 1 displays 160 nm Stoke-shift for reversibly monitoring Cu2 + and biothiols. In addition, the probe is successfully used for fluorescent cellular imaging. This strategy via modulation the ESIPT state has been used for determination of Cu2 + and Cys with satisfactory results, which further demonstrates its value of practical applications.
Liu, Yuan; Wang, Yu-Min; Zhu, Wu-Yang; Zhang, Chong-Hua; Tang, Hao; Jiang, Jian-Hui
2018-07-05
This work describes a simple and sensitive fluorescent method for detection of hydroquinone utilizing conjugated polymer nanoparticles (CPNs). The CPNs serve both as a catalyst to accelerate the conversion of hydroquinone to benzoquinone and a fluorescent probe. In the presence of hydroquinone, the fluorescence of CPNs can be effectively quenched by benzoquinone. The detection limit of hydroquinone was down to 5 nM and excellent selectivity toward possible interferences was obtained. This method was successfully applied for hydroquinone detection in lake water and satisfactory results were achieved. Copyright © 2018 Elsevier B.V. All rights reserved.
Szarka, Mate; Guttman, Andras
2017-10-17
We present the application of a smartphone anatomy based technology in the field of liquid phase bioseparations, particularly in capillary electrophoresis. A simple capillary electrophoresis system was built with LED induced fluorescence detection and a credit card sized minicomputer to prove the concept of real time fluorescent imaging (zone adjustable time-lapse fluorescence image processor) and separation controller. The system was evaluated by analyzing under- and overloaded aminopyrenetrisulfonate (APTS)-labeled oligosaccharide samples. The open source software based image processing tool allowed undistorted signal modulation (reprocessing) if the signal was inappropriate for the actual detection system settings (too low or too high). The novel smart detection tool for fluorescently labeled biomolecules greatly expands dynamic range and enables retrospective correction for injections with unsuitable signal levels without the necessity to repeat the analysis.
Eco-friendly carbon-nanodot-based fluorescent paints for advanced photocatalytic systems
Young Park, So; Uk Lee, Hyun; Lee, Young-Chul; Choi, Saehae; Hyun Cho, Dae; Sik Kim, Hee; Bang, Sunghee; Seo, Soonjoo; Chang Lee, Soon; Won, Jonghan; Son, Byung-Chul; Yang, Mino; Lee, Jouhahn
2015-01-01
Fluorescent carbon nanomaterials, especially zero-dimensional (0D) carbon nanodots (CDs), are widely used in broad biological and optoelectronic applications. CDs have unique characteristics such as strong fluorescence, biocompatibility, sun-light response, and capability of mass-production. Beyond the previous green CD obtained from harmful natural substances, we report a new type of fluid-based fluorescent CD paints (C-paints) derived from polyethylene glycol (PEG; via simple ultrasound irradiation at room temperatures) and produced in quantum yields of up to ~14%. Additionally, C-paints possess a strong, UV- and visible-light-responsive photoluminescent (PL) property. Most especially, C-paints, by incorporation into a photocatalytic system, show additional roles in the emission of fluorescent light for activation of TiO2 nanoparticles (NPs) and the resultant detoxification of most organic dyes, thus further enabling embarkation in advanced water purification. PMID:26201431
NASA Astrophysics Data System (ADS)
Zhang, Guangyun; Jia, Xiuping; Pham, Tuan D.; Crane, Denis I.
2010-01-01
The interpretation of the distribution of fluorescence in cells is often by simple visualization of microscope-derived images for qualitative studies. In other cases, however, it is desirable to be able to quantify the distribution of fluorescence using digital image processing techniques. In this paper, the challenges of fluorescence segmentation due to the noise present in the data are addressed. We report that intensity measurements alone do not allow separation of overlapping data between target and background. Consequently, spatial properties derived from neighborhood profile were included. Mathematical Morphological operations were implemented for cell boundary extraction and a window based contrast measure was developed for fluorescence puncta identification. All of these operations were applied in the proposed multistage processing scheme. The testing results show that the spatial measures effectively enhance the target separability.
Eco-friendly carbon-nanodot-based fluorescent paints for advanced photocatalytic systems.
Park, So Young; Lee, Hyun Uk; Lee, Young-Chul; Choi, Saehae; Cho, Dae Hyun; Kim, Hee Sik; Bang, Sunghee; Seo, Soonjoo; Lee, Soon Chang; Won, Jonghan; Son, Byung-Chul; Yang, Mino; Lee, Jouhahn
2015-07-23
Fluorescent carbon nanomaterials, especially zero-dimensional (0D) carbon nanodots (CDs), are widely used in broad biological and optoelectronic applications. CDs have unique characteristics such as strong fluorescence, biocompatibility, sun-light response, and capability of mass-production. Beyond the previous green CD obtained from harmful natural substances, we report a new type of fluid-based fluorescent CD paints (C-paints) derived from polyethylene glycol (PEG; via simple ultrasound irradiation at room temperatures) and produced in quantum yields of up to ~14%. Additionally, C-paints possess a strong, UV- and visible-light-responsive photoluminescent (PL) property. Most especially, C-paints, by incorporation into a photocatalytic system, show additional roles in the emission of fluorescent light for activation of TiO2 nanoparticles (NPs) and the resultant detoxification of most organic dyes, thus further enabling embarkation in advanced water purification.
Lotfi, Ali; Manzoori, Jamshid L
2016-11-01
In this study, a simple and sensitive spectrofluorimetric method is presented for the determination of fluoxetine based on the enhancing effect of silver nanoparticles (AgNPs) on the terbium-fluoxetine fluorescence emission. The AgNPs were prepared by a simple reduction method and characterized by UV-Vis spectroscopy and transmission electron microscopy. It was indicated that these AgNPs have a remarkable amplifying effect on the terbium-sensitized fluorescence of fluoxetine. The effects of various parameters such as AgNP and Tb 3+ concentration and the pH of the media were investigated. Under obtained optimal conditions, the fluorescence intensity of the terbium-fluoxetine-AgNP system was enhanced linearly by increasing the concentration of fluoxetine in the range of 0.008 to 19 mg/L. The limit of detection (b + 3s) was 8.3 × 10 -4 mg/L. The interference effects of common species found in real samples were also studied. The method had good linearity, recovery, reproducibility and sensitivity, and was satisfactorily applied for the determination of fluoxetine in tablet formulations, human urine and plasma samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Hou, Juying; Dong, Jing; Zhu, Haishuang; Teng, Xue; Ai, Shiyun; Mang, Minglin
2015-06-15
In this paper, a simple and sensitive fluorescent sensor for methyl parathion is developed based on L-tyrosine methyl ester functionalized carbon dots (Tyr-CDs) and tyrosinase system. The carbon dots are obtained by simple hydrothermal reaction using citric acid as carbon resource and L-tyrosine methyl ester as modification reagent. The carbon dots are characterized by transmission electron microscope, high resolution transmission electron microscopy, X-ray diffraction spectrum, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. The carbon dots show strong and stable photoluminescence with a quantum yield of 3.8%. Tyrosinase can catalyze the oxidation of tyrosine methyl ester on the surface of carbon dots to corresponding quinone products, which can quench the fluorescence of carbon dots. When organophosphorus pesticides (OPs) are introduced in system, they can decrease the enzyme activity, thus decrease the fluorescence quenching rate. Methyl parathion, as a model of OPs, was detected. Experimental results show that the enzyme inhibition rate is proportional to the logarithm of the methyl parathion concentration in the range 1.0×10(-10)-1.0×10(-4) M with the detection limit (S/N=3) of 4.8×10(-11) M. This determination method shows a low detection limit, wide linear range, good selectivity and high reproducibility. This sensing system has been successfully used for the analysis of cabbage, milk and fruit juice samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Liang, Meijuan; Ren, Yi; Zhang, Haijuan; Ma, Yunxia; Niu, Xiaoying; Chen, Xingguo
2017-09-01
Heteroatom-doped carbon nanoparticles (CNPs) have attracted considerable attention due to an effective improvement in their intrinsic properties. Here, a facile and simple synthesis of nitrogen, boron co-doped carbon nanoparticles (NB-CNPs) from a sole precursor, 3-aminophenylboronic acid, was performed via a one-step solid-phase approach. Because of the presence of boronic acid, NB-CNPs can be used directly as a fluorescent probe for glucose. Based on a boronic acid-triggered specific reaction, we developed a simple NB-CNP probe without surface modification for the detection of glucose. When glucose was introduced, the fluorescence of NB-CNPs was suppressed through a surface-quenching states mechanism. Obvious fluorescence quenching allowed the highly sensitive determination of glucose with a limit of detection of 1.8 μM. Moreover, the proposed method has been successfully used to detect glucose in urine from people with diabetes, suggesting potential application in sensing glucose. Copyright © 2017 John Wiley & Sons, Ltd.
Compound parabolic concentrator optical fiber tip for FRET-based fluorescent sensors
NASA Astrophysics Data System (ADS)
Ul Hassan, Hafeez; Nielsen, Kristian; Aasmul, Soren; Bang, Ole
2015-09-01
The Compound Parabolic Concentrator (CPC) optical fiber tip shape has been proposed for intensity based fluorescent sensors working on the principle of FRET (Förster Resonance Energy Transfer). A simple numerical Zemax model has been used to optimize the CPC tip geometry for a step-index multimode polymer optical fiber for an excitation and emission wavelength of 550 nm and 650nm, respectively. The model suggests an increase of a factor of 1.6 to 4 in the collected fluorescent power for an ideal CPC tip, as compared to the plane-cut fiber tip for fiber lengths between 5 and 45mm.
Multivariate optical element platform for compressed detection of fluorescence markers
NASA Astrophysics Data System (ADS)
Priore, Ryan J.; Swanstrom, Joseph A.
2014-05-01
The success of a commercial fluorescent diagnostic assay is dependent on the selection of a fluorescent biomarker; due to the broad nature of fluorescence biomarker emission profiles, only a small number of fluorescence biomarkers may be discriminated from each other as a function of excitation source. Multivariate Optical Elements (MOEs) are thin-film devices that encode a broad band, spectroscopic pattern allowing a simple broadband detector to generate a highly sensitive and specific detection for a target analyte. MOEs have historically been matched 1:1 to a discrete analyte or class prediction; however, MOE filter sets are capable of sensing projections of the original sparse spectroscopic space enabling a small set of MOEs to discriminate a multitude of target analytes. This optical regression can offer real-time measurements with relatively high signal-to-noise ratios that realize the advantages of multiplexed detection and pattern recognition in a simple optical instrument. The specificity advantage of MOE-based sensors allows fluorescent biomarkers that were once incapable of discrimination from one another via optical band pass filters to be employed in a common assay panel. A simplified MOE-based sensor may ultimately reduce the requirement for highly trained operators as well as move certain life science applications like disease prognostication from the laboratory to the point of care. This presentation will summarize the design and fabrication of compressed detection MOE filter sets for detecting multiple fluorescent biomarkers simultaneously with strong spectroscopic interference as well as comparing the detection performance of the MOE sensor with traditional optical band pass filter methodologies.
Zeller, Perrine; Ploux, Olivier; Méjean, Annick
2016-03-01
Cyanobacteria contain pigments, which generate auto-fluorescence that interferes with fluorescence in situ hybridization (FISH) imaging of cyanobacteria. We describe simple chemical treatments using CuSO4 or H2O2 that significantly reduce the auto-fluorescence of Microcystis strains. These protocols were successfully applied in FISH experiments using 16S rRNA specific probes and filamentous cyanobacteria. Copyright © 2016 Elsevier B.V. All rights reserved.
Prince, Linda M
2015-01-01
Inter-simple sequence repeat PCR (ISSR-PCR) is a fast, inexpensive genotyping technique based on length variation in the regions between microsatellites. The method requires no species-specific prior knowledge of microsatellite location or composition. Very small amounts of DNA are required, making this method ideal for organisms of conservation concern, or where the quantity of DNA is extremely limited due to organism size. ISSR-PCR can be highly reproducible but requires careful attention to detail. Optimization of DNA extraction, fragment amplification, and normalization of fragment peak heights during fluorescent detection are critical steps to minimizing the downstream time spent verifying and scoring the data.
Siegel, Nisan; Storrie, Brian; Bruce, Marc
2016-01-01
FINCH holographic fluorescence microscopy creates high resolution super-resolved images with enhanced depth of focus. The simple addition of a real-time Nipkow disk confocal image scanner in a conjugate plane of this incoherent holographic system is shown to reduce the depth of focus, and the combination of both techniques provides a simple way to enhance the axial resolution of FINCH in a combined method called “CINCH”. An important feature of the combined system allows for the simultaneous real-time image capture of widefield and holographic images or confocal and confocal holographic images for ready comparison of each method on the exact same field of view. Additional GPU based complex deconvolution processing of the images further enhances resolution. PMID:26839443
NASA Astrophysics Data System (ADS)
Pachaiappan, Rekha; Prakasarao, Aruna; Manoharan, Yuvaraj; Dornadula, Koteeswaran; Singaravelu, Ganesan
2017-02-01
During metabolism the metabolites such as hormones, proteins and enzymes were released in to the blood stream by the cells. These metabolites reflect any change that occurs due to any disturbances in normal metabolic function of the human system. This was well observed with the altered spectral signatures observed with fluorescence spectroscopic technique. Previously many have reported on the significance of native fluorescence spectroscopic method in the diagnosis of cancer. As fluorescence spectroscopy is sensitive and simple, it has complementary techniques such as excitation-emission matrix, synchronous and polarization. The fluorescence polarization measurement provides details about any association or binding reactions and denaturing effects that occurs due to change in the micro environment of cells and tissues. In this study, we have made an attempt in the diagnosis of oral cancer at 405 nm excitation using fluorescence polarization measurement. The fluorescence anisotropic values calculated from polarized fluorescence spectral data of normal and oral cancer subjects yielded a good accuracy when analyzed with linear discriminant analysis based artificial neural network. The results will be discussed in detail.
Li, Duo; Qiao, Zhenzhen; Yu, Yanru; Tang, Jinlu; He, Xiaoxiao; Shi, Hui; Ye, Xiaosheng; Lei, Yanli; Wang, Kemin
2018-01-25
A facile, general and turn-on nucleus imaging strategy was first developed based on in situ fluorescence activation of C-rich dark silver nanoclusters by G-rich telomeres. After a simple incubation without washing, nanoclusters could selectively stain the nucleus with intense red luminescence, which was confirmed using fixed/living cells and several cell lines.
NASA Astrophysics Data System (ADS)
Shen, Youming; Zhang, Xiangyang; Zhang, Youyu; Zhang, Chunxiang; Jin, Junling; Li, Haitao
2017-10-01
A new turn-on phthalimide fluorescent probe has designed and synthesized for sensing cysteine (Cys) based on excited state intramolecular proton transfer (ESIPT) process. It is consisted of a 3-hydroxyphthalimide derivative moiety as the fluorophore and an acrylic ester group as a recognition receptor. The acrylic ester acts as an ESIPT blocking agent. Upon addition of cystein, intermolecular nucleophilic attack of cysteine on acrylic ester releases the fluorescent 3-hydroxyphthalimide derivative, thereby enabling the ESIPT process and leading to enhancement of fluorescence. The probe displays high sensitivity, excellent selectivity and with large Stokes shift toward cysteine. The linear interval range of the fluorescence titration ranged from 0 to 1.0 × 10- 5 M and detection limit is low (6 × 10- 8 M). In addition, the probe could be used for bio-imaging in living cells.
Simple apparatus for polarization sensing of analytes
NASA Astrophysics Data System (ADS)
Gryczynski, Zygmunt; Gryczynski, Ignacy; Lakowicz, Joseph R.
2000-09-01
We describe a simple device for fluorescence sensing based on an unexpansive light source, a dual photocell and a Watson bridge. The emission is detected from two fluorescent samples, one of which changes intensity in response to the analyte. The emission from these two samples is observed through two orthogonally oriented polarizers and an analyzer polarizer. The latter polarizer is rotated to yield equal intensities from both sides of the dual photocell, as determined by a zero voltage from the Watson bridge. Using this device, we are able to measure fluorescein concentration to an accuracy near 2% at 1 (mu) M fluorescein, and pH values accurate to +/- 0.02 pH units. We also use this approach with a UV hand lamp and a glucose-sensitive protein to measure glucose concentrations near 2 (mu) M to an accuracy of +/- 0.1 (mu) M. This approach requires only simple electronics, which can be battery powered. Additionally, the method is generic, and can be applied with any fluorescent sample that displays a change in intensity. One can imagine this approach being used to develop portable point-of-care clinical devices.
Huertas-Pérez, José Fernando; Arroyo-Manzanares, Natalia; Hitzler, Dominik; Castro-Guerrero, Francisco Germán; Gámiz-Gracia, Laura; García-Campaña, Ana M
2018-04-15
A fast and simple analytical method was developed and characterized for the determination of aflatoxins (B 1 , B 2 , G 1 and G 2 ) in rice. The procedure is based on a simple solid-liquid extraction without further clean-up, and analysis by ultra-high performance liquid chromatography coupled with fluorescence detection. Fluorescence emission of aflatoxins B 1 and G 1 was enhanced by post-column chemical derivatization using pyridinium bromide perbromide. The analytical method was satisfactorily characterized in white and brown rice. Under optimum conditions, external calibration in solvent could be used for quantification purposes and limits of quantification were below the maximum contents established by the European Union regulation for these contaminants/commodity group combination (0.07-0.14 µg/kg for white rice and 0.20-0.28 µg/kg for brown rice). Recovery studies carried out at three different concentration levels (0.5, 2 and 5 µg/kg) showed values in the range of 84.5-105.3%, and RSDs ≤ 5%. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhan, Lei; Peng, Li; Yu, Yan; Zhen, Shu Jun; Huang, Cheng Zhi
2012-11-07
The very simple and general spectrofluorometry of cellular prion protein (PrP(C)) is reported in this contribution based on the on-off noncovalent interaction of fluorescent dye-labelled PrP(C) DNA aptamers with multi-walled carbon nanotubes (MWCNTs). Due to the π-π stacking interaction between the DNA bases of the aptamer and the carbon nanotubes, the fluorescent dye and the MWCNTs are brought into close proximity, which leads to fluorescence quenching with a ratio of up to 87%. However, further addition of PrP(C), which disturbs the π-π interaction owing to the strong and specific binding of the aptamer to PrP(C), driving the aptamer away from the surface of the MWCNTs, restored the quenched fluorescence. This recovered fluorescence intensity was found to be in linear proportion to the PrP(C) concentration in the range of 8.2 to 81.7 nM, which builds the basis of the spectrofluorometry of the cellular prion protein.
NASA Astrophysics Data System (ADS)
Ding, Longhua; Yang, Hongmei; Ge, Shenguang; Yu, Jinghua
2018-03-01
A simple and effective fluorescent assay for the determination of vitamin B12 was developed. In this study, carbon dots (CDs) were prepared by one-pot hydrothermal method and directly used as a fluorophore in the inner filter effect (IFE). Both of the maximum absorption peak of vitamin B12 and excitation maxima of CDs are located at 360 nm, hence, the excited light of CDs can be absorbed by vitamin B12, resulting in the fluorescence reduction of CDs. And the fluorescence intensity of CDs decreases with the increasing concentration of vitamin B12. This IFE-based sensing strategy shows a good linear relationship between the normalized fluorescence intensity and the concentration of vitamin B12 ranging from 0 to 60 μM, with a limit of detection (LOD) of 0.1 μM at a signal-to-noise ratio of 3. Furthermore, this proposed approach was successfully applied to vitamin B12 sensing in injections. This IFE sensing platform based on various fluorescent nanomaterials has a high promise for the detection of other biomolecules due to its inherent convenience.
NASA Astrophysics Data System (ADS)
Daniel, Jonathan; Godin, Antoine G.; Palayret, Matthieu; Lounis, Brahim; Cognet, Laurent; Blanchard-Desce, Mireille
2016-03-01
Based on an original molecular-based design, we present bright and photostable fluorescent organic nanoparticles (FONs) showing excellent colloidal stability in various aqueous environments. Complementary near-infrared emitting and green emitting FONs were prepared using a simple, fast and robust protocol. Both types of FONs could be simultaneously imaged at the single-particle level in solution as well as in biological environments using a monochromatic excitation and a dual-color fluorescence microscope. No evidence of acute cytotoxicity was found upon incubation of live cells with mixed solutions of FONs, and both types of nanoparticles were found internalized in the cells where their motion could be simultaneously tracked at video-rate up to minutes. These fluorescent organic nanoparticles open a novel non-toxic alternative to existing nanoparticles for imaging biological structures, compatible with live-cell experiments and specially fitted for multicolor single particle tracking.
NASA Astrophysics Data System (ADS)
Hwang, Kyo Min; Lee, Song Eun; Lee, Sungkyu; Yoo, Han Kyu; Baek, Hyun Jung; Kim, Young Kwan; Kim, Jwajin; Yoon, Seung Soo
2016-08-01
In this study, we fabricated hybrid white organic light-emitting diodes (WOLEDs) based on triplet harvesting with a simple structure. All the hole transporting material and host in the emitting layer (EML) of devices utilized the same material N,N'-di-1-naphthalenyl-N,N'-diphenyl [1,1':4',1″:4″,1‴-quaterphenyl]-4,4‴-diamine (4P-NPD), which is known to be blue fluorescent material. Simple hybrid WOLEDs were fabricated with blue fluorescent, green and red phosphorescent materials. We investigated the effect of triplet harvesting (TH) by an exciton generation zone on simple hybrid WOLEDs. The simple hybrid WOLEDs characteristically had a dominant hole mobility, so an exciton generation zone was expected in the EML. Additionally, the optimal the thickness of the hole transporting layer and electron transporting layer was fabricated a simple hybrid WOLEDs. The simple hybrid WOLED exhibits a maximum luminous efficiency of 29.3 cd/A and a maximum external quantum efficiency of 11.2%. The Commission Internationale de l'Éclairage (International Commission on Illumination) coordinates were (0.45, 0.43) at about 10,000 cd/m2.
Robust, directed assembly of fluorescent nanodiamonds.
Kianinia, Mehran; Shimoni, Olga; Bendavid, Avi; Schell, Andreas W; Randolph, Steven J; Toth, Milos; Aharonovich, Igor; Lobo, Charlene J
2016-10-27
Arrays of fluorescent nanoparticles are highly sought after for applications in sensing, nanophotonics and quantum communications. Here we present a simple and robust method of assembling fluorescent nanodiamonds into macroscopic arrays. Remarkably, the yield of this directed assembly process is greater than 90% and the assembled patterns withstand ultra-sonication for more than three hours. The assembly process is based on covalent bonding of carboxyl to amine functional carbon seeds and is applicable to any material, and to non-planar surfaces. Our results pave the way to directed assembly of sensors and nanophotonics devices.
Estimating the Biodegradability of Treated Sewage Samples Using Synchronous Fluorescence Spectra
Lai, Tien M.; Shin, Jae-Ki; Hur, Jin
2011-01-01
Synchronous fluorescence spectra (SFS) and the first derivative spectra of the influent versus the effluent wastewater samples were compared and the use of fluorescence indices is suggested as a means to estimate the biodegradability of the effluent wastewater. Three distinct peaks were identified from the SFS of the effluent wastewater samples. Protein-like fluorescence (PLF) was reduced, whereas fulvic and/or humic-like fluorescence (HLF) were enhanced, suggesting that the two fluorescence characteristics may represent biodegradable and refractory components, respectively. Five fluorescence indices were selected for the biodegradability estimation based on the spectral features changing from the influent to the effluent. Among the selected indices, the relative distribution of PLF to the total fluorescence area of SFS (Index II) exhibited the highest correlation coefficient with total organic carbon (TOC)-based biodegradability, which was even higher than those obtained with the traditional oxygen demand-based parameters. A multiple regression analysis using Index II and the area ratio of PLF to HLF (Index III) demonstrated the enhancement of the correlations from 0.558 to 0.711 for TOC-based biodegradability. The multiple regression equation finally obtained was 0.148 × Index II − 4.964 × Index III − 0.001 and 0.046 × Index II − 1.128 × Index III + 0.026. The fluorescence indices proposed here are expected to be utilized for successful development of real-time monitoring using a simple fluorescence sensing device for the biodegradability of treated sewage. PMID:22164023
Estimating the biodegradability of treated sewage samples using synchronous fluorescence spectra.
Lai, Tien M; Shin, Jae-Ki; Hur, Jin
2011-01-01
Synchronous fluorescence spectra (SFS) and the first derivative spectra of the influent versus the effluent wastewater samples were compared and the use of fluorescence indices is suggested as a means to estimate the biodegradability of the effluent wastewater. Three distinct peaks were identified from the SFS of the effluent wastewater samples. Protein-like fluorescence (PLF) was reduced, whereas fulvic and/or humic-like fluorescence (HLF) were enhanced, suggesting that the two fluorescence characteristics may represent biodegradable and refractory components, respectively. Five fluorescence indices were selected for the biodegradability estimation based on the spectral features changing from the influent to the effluent. Among the selected indices, the relative distribution of PLF to the total fluorescence area of SFS (Index II) exhibited the highest correlation coefficient with total organic carbon (TOC)-based biodegradability, which was even higher than those obtained with the traditional oxygen demand-based parameters. A multiple regression analysis using Index II and the area ratio of PLF to HLF (Index III) demonstrated the enhancement of the correlations from 0.558 to 0.711 for TOC-based biodegradability. The multiple regression equation finally obtained was 0.148 × Index II - 4.964 × Index III - 0.001 and 0.046 × Index II - 1.128 × Index III + 0.026. The fluorescence indices proposed here are expected to be utilized for successful development of real-time monitoring using a simple fluorescence sensing device for the biodegradability of treated sewage.
A slippery molecular assembly allows water as a self-erasable security marker
Thirumalai, Rajasekaran; Mukhopadhyay, Rahul Dev; Praveen, Vakayil K.; Ajayaghosh, Ayyappanpillai
2015-01-01
Protection of currency and valuable documents from counterfeit continues to be a challenge. While there are many embedded security features available for document safety, they are not immune to forgery. Fluorescence is a sensitive property, which responds to external stimuli such as solvent polarity, temperature or mechanical stress, however practical use in security applications is hampered due to several reasons. Therefore, a simple and specific stimuli responsive security feature that is difficult to duplicate is of great demand. Herein we report the design of a fluorescent molecular assembly on which water behaves as a self-erasable security marker for checking the authenticity of documents at point of care. The underlying principle involves the disciplined self-assembly of a tailor-made fluorescent molecule, which initially form a weak blue fluorescence (λem = 425 nm, Φf = 0.13) and changes to cyan emission (λem = 488 nm,Φf = 0.18) in contact with water due to a reversible molecular slipping motion. This simple chemical tool, based on the principles of molecular self-assembly and fluorescence modulation, allows creation of security labels and optically masked barcodes for multiple documents authentication. PMID:25940779
A slippery molecular assembly allows water as a self-erasable security marker.
Thirumalai, Rajasekaran; Mukhopadhyay, Rahul Dev; Praveen, Vakayil K; Ajayaghosh, Ayyappanpillai
2015-05-05
Protection of currency and valuable documents from counterfeit continues to be a challenge. While there are many embedded security features available for document safety, they are not immune to forgery. Fluorescence is a sensitive property, which responds to external stimuli such as solvent polarity, temperature or mechanical stress, however practical use in security applications is hampered due to several reasons. Therefore, a simple and specific stimuli responsive security feature that is difficult to duplicate is of great demand. Herein we report the design of a fluorescent molecular assembly on which water behaves as a self-erasable security marker for checking the authenticity of documents at point of care. The underlying principle involves the disciplined self-assembly of a tailor-made fluorescent molecule, which initially form a weak blue fluorescence (λem = 425 nm, Φf = 0.13) and changes to cyan emission (λem = 488 nm,Φf = 0.18) in contact with water due to a reversible molecular slipping motion. This simple chemical tool, based on the principles of molecular self-assembly and fluorescence modulation, allows creation of security labels and optically masked barcodes for multiple documents authentication.
An aptamer-based fluorescence bio-sensor for chiral recognition of arginine enantiomers
NASA Astrophysics Data System (ADS)
Yuan, Haiyan; Huang, Yunmei; Yang, Jidong; Guo, Yuan; Zeng, Xiaoqing; Zhou, Shang; Cheng, Jiawei; Zhang, Yuhui
2018-07-01
In this study, a novel aptamer - based fluorescence bio-sensor (aptamer-AuNps) was developed for chiral recognition of arginine (Arg) enantiomers based on aptamer and gold nanoparticles (AuNps). Carboxyfluorescein (FAM) labeled aptamers (Apt) were absorbed on AuNps and their fluorescence intensity could be significantly quenched by AuNps based on fluorescence resonance energy transfer (FRET). Once D-Arg or L-Arg were added into the above solution, the aptamer specifically bind to Arg enantiomers and released from AuNps, so the fluorescence intensity of D-Arg system and L-Arg system were all enhanced. The affinity of Apt to L-Arg is tighter to D-Arg, so the enhanced fluorescence signals of L-Arg system was stronger than D-Arg system. What's more, the enhanced fluorescence were directly proportional to the concentration of D-Arg and L-Arg ranging from 0-300 nM and 0-400 nM with related coefficients of 0.9939 and 0.9952, respectively. Furthermore, the method was successfully applied to detection L-Arg in human urine samples with satisfactory results. Eventually, a simple "OR" logic gate with D-Arg &L-Arg as inputs and AuNps aggregation state as outputs was fabricated, which can help us understand the chiral recognition process deeply.
Durán, Gema M; Contento, Ana M; Ríos, Ángel
2013-11-01
Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L(-1). The lineal range was between 10-5×10(3) ng L(-1). RSD values in the range of 71-102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Li; Carnegie, Graeme K.
2013-01-01
Among methods to study protein-protein interaction inside cells, Bimolecular Fluorescence Complementation (BiFC) is relatively simple and sensitive. BiFC is based on the production of fluorescence using two non-fluorescent fragments of a fluorescent protein (Venus, a Yellow Fluorescent Protein variant, is used here). Non-fluorescent Venus fragments (VN and VC) are fused to two interacting proteins (in this case, AKAP-Lbc and PDE4D3), yielding fluorescence due to VN-AKAP-Lbc-VC-PDE4D3 interaction and the formation of a functional fluorescent protein inside cells. BiFC provides information on the subcellular localization of protein complexes and the strength of protein interactions based on fluorescence intensity. However, BiFC analysis using microscopy to quantify the strength of protein-protein interaction is time-consuming and somewhat subjective due to heterogeneity in protein expression and interaction. By coupling flow cytometric analysis with BiFC methodology, the fluorescent BiFC protein-protein interaction signal can be accurately measured for a large quantity of cells in a short time. Here, we demonstrate an application of this methodology to map regions in PDE4D3 that are required for the interaction with AKAP-Lbc. This high throughput methodology can be applied to screening factors that regulate protein-protein interaction. PMID:23979513
Wang, Li; Carnegie, Graeme K
2013-08-15
Among methods to study protein-protein interaction inside cells, Bimolecular Fluorescence Complementation (BiFC) is relatively simple and sensitive. BiFC is based on the production of fluorescence using two non-fluorescent fragments of a fluorescent protein (Venus, a Yellow Fluorescent Protein variant, is used here). Non-fluorescent Venus fragments (VN and VC) are fused to two interacting proteins (in this case, AKAP-Lbc and PDE4D3), yielding fluorescence due to VN-AKAP-Lbc-VC-PDE4D3 interaction and the formation of a functional fluorescent protein inside cells. BiFC provides information on the subcellular localization of protein complexes and the strength of protein interactions based on fluorescence intensity. However, BiFC analysis using microscopy to quantify the strength of protein-protein interaction is time-consuming and somewhat subjective due to heterogeneity in protein expression and interaction. By coupling flow cytometric analysis with BiFC methodology, the fluorescent BiFC protein-protein interaction signal can be accurately measured for a large quantity of cells in a short time. Here, we demonstrate an application of this methodology to map regions in PDE4D3 that are required for the interaction with AKAP-Lbc. This high throughput methodology can be applied to screening factors that regulate protein-protein interaction.
Spinach RNA aptamer detects lead (II) with high selectivity†
DasGupta, Saurja; Shelke, Sandip A.; Li, Nan-sheng
2015-01-01
Spinach RNA aptamer contains a G-quadruplex motif that serves as a platform for binding and fluorescence activation of a GFP-like fluorophore. Here we show that Pb2+ induces formation of Spinach’s G-quadruplex and activates fluorescence with high selectivity and sensitivity. This device establishes the first example of an RNA-based sensor that provides a simple and inexpensive tool for Pb2+ detection. PMID:25940073
Burnette, Dylan T; Sengupta, Prabuddha; Dai, Yuhai; Lippincott-Schwartz, Jennifer; Kachar, Bechara
2011-12-27
Superresolution imaging techniques based on the precise localization of single molecules, such as photoactivated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), achieve high resolution by fitting images of single fluorescent molecules with a theoretical Gaussian to localize them with a precision on the order of tens of nanometers. PALM/STORM rely on photoactivated proteins or photoswitching dyes, respectively, which makes them technically challenging. We present a simple and practical way of producing point localization-based superresolution images that does not require photoactivatable or photoswitching probes. Called bleaching/blinking assisted localization microscopy (BaLM), the technique relies on the intrinsic bleaching and blinking behaviors characteristic of all commonly used fluorescent probes. To detect single fluorophores, we simply acquire a stream of fluorescence images. Fluorophore bleach or blink-off events are detected by subtracting from each image of the series the subsequent image. Similarly, blink-on events are detected by subtracting from each frame the previous one. After image subtractions, fluorescence emission signals from single fluorophores are identified and the localizations are determined by fitting the fluorescence intensity distribution with a theoretical Gaussian. We also show that BaLM works with a spectrum of fluorescent molecules in the same sample. Thus, BaLM extends single molecule-based superresolution localization to samples labeled with multiple conventional fluorescent probes.
Xiang, Guoqiang; Wang, Yule; Zhang, Heng; Fan, Huanhuan; Fan, Lu; He, Lijun; Jiang, Xiuming; Zhao, Wenjie
2018-09-15
In this work, a simple and effective strategy for designing a ratiometric fluorescent nanosensor was described. A carbon dots (CDs) based dual-emission nanosensor for nitrite was prepared by coating the CDs on to dye-doped silica nanoparticles. Dual-emission silica nanoparticles fluorescence was quenched in sulfuric acid using potassium bromate (KBrO 3 ). The nitrite present catalyzed the KBrO 3 oxidation, resulting in ratiometric fluorescence response of the dual-emission silica nanoparticles. Several important parameters affecting the performance of the nanosensor were investigated. Under optimized conditions, the limit of detection was 1.0 ng mL -1 and the linear range 10-160 ng mL -1 . Furthermore, the sensor was suitable for nitrite determination in different food samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xiang, Guo-Qiang; Ren, Yue; Xia, Yin; Mao, Wenjie; Fan, Chao; Guo, Si-Yu; Wang, Pan-Pan; Yang, Deng-Hui; He, Lijun; Jiang, Xiuming
2017-04-01
A simple and effective strategy for designing a ratiometric fluorescent nanosensor is described in this work. A carbon dots (CDs) based dual-emission nanosensor for Bisphenol A (BPA) was prepared by coating CDs on the surface of dye-doped silica nanoparticles. The fluorescence of dual-emission silica nanoparticles was quenched in hydrochloric acid by potassium bromate (KBrO3) oxidation; BPA inhibited KBrO3 oxidation, resulting in the ratiometric fluorescence response of dual-emission silica nanoparticles. Several important parameters affecting the performance of the nanosensor were investigated and optimized. The detection limit of this nanosensor was 0.80 ng mL- 1 with a linear range from 10 to 500 ng mL- 1. This was applied successfully to determine BPA in the leached solution of different plastic products with satisfactory results.
Xue, Qingwang; Liu, Chunxue; Li, Xia; Dai, Li; Wang, Huaisheng
2018-04-18
Various fluorescent sensing systems for miRNA detection have been developed, but they mostly contain enzymatic amplification reactions and label procedures. The strict reaction conditions of tool enzymes and the high cost of labeling limit their potential applications, especially in complex biological matrices. Here, we have addressed the difficult problems and report a strategy for label-free fluorescent DNA dendrimers based on enzyme-free nonlinear hybridization chain reaction (HCR)-mediated multiple G-quadruplex for simple, sensitive, and selective detection of miRNAs with low-background signal. In the strategy, a split G-quadruplex (3:1) sequence is ingeniously designed at both ends of two double-stranded DNAs, which is exploited as building blocks for nonlinear HCR assembly, thereby acquiring a low background signal. A hairpin switch probe (HSP) was employed as recognition and transduction element. Upon sensing the target miRNA, the nonlinear HCR assembly of two blocks (blocks-A and blocks-B) was initiated with the help of two single-stranded DNA assistants, resulting in chain-branching growth of DNA dendrimers with multiple G-quadruplex incorporation. With the zinc(II)-protoporphyrin IX (ZnPPIX) selectively intercalated into the multiple G-quadruplexes, fluorescent DNA dendrimers were obtained, leading to an exponential fluorescence intensity increase. Benefiting from excellent performances of nonlinear HCR and low background signal, this strategy possesses the characteristics of a simplified reaction operation process, as well as high sensitivity. Moreover, the proposed fluorescent sensing strategy also shows preferable selectivity, and can be implemented without modified DNA blocks. Importantly, the strategy has also been tested for miRNA quantification with high confidence in breast cancer cells. Thus, this proposed strategy for label-free fluorescent DNA dendrimers based on a nonlinear HCR-mediated multiple G-quadruplex will be turned into an alternative approach for simple, sensitive, and selective miRNA quantification.
Challenges in paper-based fluorogenic optical sensing with smartphones
NASA Astrophysics Data System (ADS)
Ulep, Tiffany-Heather; Yoon, Jeong-Yeol
2018-05-01
Application of optically superior, tunable fluorescent nanotechnologies have long been demonstrated throughout many chemical and biological sensing applications. Combined with microfluidics technologies, i.e. on lab-on-a-chip platforms, such fluorescent nanotechnologies have often enabled extreme sensitivity, sometimes down to single molecule level. Within recent years there has been a peak interest in translating fluorescent nanotechnology onto paper-based platforms for chemical and biological sensing, as a simple, low-cost, disposable alternative to conventional silicone-based microfluidic substrates. On the other hand, smartphone integration as an optical detection system as well as user interface and data processing component has been widely attempted, serving as a gateway to on-board quantitative processing, enhanced mobility, and interconnectivity with informational networks. Smartphone sensing can be integrated to these paper-based fluorogenic assays towards demonstrating extreme sensitivity as well as ease-of-use and low-cost. However, with these emerging technologies there are always technical limitations that must be addressed; for example, paper's autofluorescence that perturbs fluorogenic sensing; smartphone flash's limitations in fluorescent excitation; smartphone camera's limitations in detecting narrow-band fluorescent emission, etc. In this review, physical optical setups, digital enhancement algorithms, and various fluorescent measurement techniques are discussed and pinpointed as areas of opportunities to further improve paper-based fluorogenic optical sensing with smartphones.
Ye, Yu-Dan; Xia, Li; Xu, Dang-Dang; Xing, Xiao-Jing; Pang, Dai-Wen; Tang, Hong-Wu
2016-11-15
Based on the remarkable difference between the interactions of carbon nanoparticles (CNPs) oxide with single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA), and the fact that fluorescence of DNA-stabilized silver nanoclusters (AgNCs) can be quenched by CNPs oxide, DNA-functionalized AgNCs were applied as label-free fluorescence probes and a novel fluorescence resonance energy transfer (FRET) sensor was successfully constructed for the detection of human immunodeficiency virus (HIV) DNA sequences. CNPs oxide were prepared with the oxidation of candle soot, hence it is simple, time-saving and low-cost. The strategy of dual AgNCs probes was applied to improve the detection sensitivity by using dual- probe capturing the same target DNA in a sandwich mode and as the fluorescence donor, and using CNPs oxide as the acceptor. In the presence of target DNA, a dsDNA hybrid forms, leading to the desorption of the ssDNA-AgNCs probes from CNPs oxide, and the recovering of fluorescence of the AgNCs in a HIV-DNA concentration-dependent manner. The results show that HIV-DNA can be detected in the range of 1-50nM with a detection limit of 0.40nM in aqueous buffer. The method is simple, rapid and sensitive with no need of labeled fluorescent probes, and moreover, the design of fluorescent dual-probe makes full use of the excellent fluorescence property of AgNCs and further improves the detection sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.
A Schiff-based colorimetric fluorescent sensor with the potential for detection of fluoride ions.
Huang, Cheng-Yin; Wan, Chin-Feng; Chir, Jiun-Ly; Wu, An-Tai
2013-11-01
A simple Schiff-based colorimetric fluorescent receptor 1 was prepared. It exhibits a "turn-on-type" mode with high sensitivity in the presence of F(-). The change in color is very easily observed by the naked eye in the presence of F(-), whereas other anions do not induce such a change. Job plot indicated a 1:2 complexation stoichiometry between receptor 1 and F(-). The association constant for 1-F(-) in CH3CN was determined as 1.32*10(5) M(-2) by a Hill plot.
Fast-Response Turn-on Fluorescent Probes Based on Thiolysis of NBD Amine for H2 S Bioimaging.
Wang, Runyu; Li, Zhifei; Zhang, Changyu; Li, Yanyan; Xu, Guoce; Zhang, Qiang-Zhe; Li, Lu-Yuan; Yi, Long; Xi, Zhen
2016-05-17
Hydrogen sulfide (H2 S) is an important endogenous signaling molecule with multiple biological functions. New selective fluorescent turn-on probes based on fast thiolyling of NBD (7-nitro-1,2,3-benzoxadiazole) amine were explored for sensing H2 S in aqueous buffer and in living cells. The syntheses of both probes are simple and quite straightforward. The probes are highly sensitive and selective toward H2 S over other biologically relevant species. The fluorescein-NBD-based probe showed 65-fold green fluorescent increase upon H2 S activation. The rhodamine-NBD-based probe reacted rapidly with H2 S (t1/2 ≈1 min) to give a 4.5-fold increase in red fluorescence. Moreover, both probes were successfully used for monitoring H2 S in living cells and in mice. Based on such probe-based tools, we could observe H2 O2 -induced H2 S biogenesis in a concentration-dependent and time-dependent fashion in living cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Samanta, Anuva; Paul, Bijan Kumar; Guchhait, N.
2011-05-01
In this report we have studied micellization process of anionic, cationic and non-ionic surfactants using N,N-dimethylaminonapthyl-(acrylo)-nitrile (DMANAN) as an external fluorescence probe. Micropolarity, microviscosity, critical micellar concentration of these micelles based on steady state absorption and fluorescence and time resolved emission spectroscopy of the probe DMANAN show that the molecule resides in the micelle-water interface for ionic micelles and in the core for the non-ionic micelle. The effect of variation of pH of the micellar solution as well as fluorescence quenching measurements of DMANAN provide further support for the location of the probe in the micelles.
NASA Astrophysics Data System (ADS)
Sankar, Renu; Rahman, Pattanathu K. S. M.; Varunkumar, Krishnamoorthy; Anusha, Chidambaram; Kalaiarasi, Arunachalam; Shivashangari, Kanchi Subramanian; Ravikumar, Vilwanathan
2017-02-01
Nanomaterials based fluorescent agents are rapidly becoming significant and promising transformative tools for improving medical diagnostics for extensive in vivo imaging modalities. Compared with conventional fluorescent agents, nano-fluorescence has capabilities to improve the in vivo detection and enriched targeting efficiencies. In our laboratory we synthesized fluorescent metal nanoparticles of silver, copper and iron using Curcuma longa tuber powder by simple reduction. The physicochemical properties of the synthesized metal nanoparticles were attained using UV-visible spectrophotometry, scanning electron microscopy with EDAX spectroscopy, dynamic light scattering, Fourier-transform infrared spectroscopy and X-ray diffraction. The Curcuma longa tuber powder has one of the bioactive compound Curcumin might act as a capping agent during the synthesis of nanoparticles. The synthesized metal nanoparticles fluorescence property was confirmed by spectrofluorometry. When compared with copper and iron nanoparticles the silver nanoparticles showed high fluorescence intensity under spectrofluorometry. Moreover, in vitro cell images of the silver nanoparticles in A549 cell lines also correlated with the results of spectrofluorometry. These silver nanoparticles show inspiring cell-imaging applications. They enter into cells without any further modifications, and the fluorescence property can be utilized for fluorescence-based cell imaging applications.
Long, Lingliang; Wu, Yanjun; Wang, Lin; Gong, Aihua; Hu, Rongfeng; Zhang, Chi
2016-02-18
The reaction-based fluorescent sensors have attracted increasing attention in the past decades. However, the application of these sensors for accurate sensing was significantly retarded by the background fluorescence from the sensors themselves. In this work, we demonstrated a novel strategy that the background fluorescence of the sensor could be completely eliminated by the combined effect of multiple fluorescence quenching groups. Based on this new strategy, as proof-of-principle study, a fluorescent sensor (CuFS) for Cu(2+) was judiciously developed. In CuFS, three types of fluorescence quenching groups were directly tethered to a commonly used coumarin fluorophore. The fluorescence of coumarin fluorophore in CuFS was completely suppressed by the combined effect of these fluorescence quenching groups. Upon treatment with 22 μM Cu(2+), sensor CuFS achieved a dramatic fluorescence enhancement (fluorescence intensity enhanced up to 811-fold) centered at 469 nm. The detection limits was determined to be 12.3 nM. The fluorescence intensity enhancement also showed a good linearity with the Cu(2+) concentration in the range of 12.3 nM to 2 μM. By fabricating test strips, sensor CuFS can be utilized as a simple tool to detect Cu(2+) in water samples. Furthermore, the fluorescent sensor was successfully applied in detecting different concentration of Cu(2+) in living cells. Copyright © 2015 Elsevier B.V. All rights reserved.
Heil, John R; Nordeste, Ricardo F; Charles, Trevor C
2011-04-01
Here we report a simple cost-effective device for screening colonies on plates for expression of the monomeric red fluorescent protein mRFP1 and the fluorescent dye Nile red. This device can be built from any simple light source, in our case a Quebec Colony Counter, and cost-effective theatre gels. The device can be assembled in as little as 20 min, and it produces excellent results when screening a large number of colonies.
Liu, Jia-Ming; Lin, Li-ping; Wang, Xin-Xing; Lin, Shao-Qin; Cai, Wen-Lian; Zhang, Li-Hong; Zheng, Zhi-Yong
2012-06-07
Based on the ability of lysine (Lys) to enhance the fluorescence intensity of bovine serum albumin modified-carbon dots (CDs-BSA) to decrease surface defects and quench fluorescence of the CDs-BSA-Lys system in the presence of Cu(2+) under conditions of phosphate buffer (PBS, pH = 5.0) at 45 °C for 10 min, a sensitive Lys enhancing CDs-BSA fluorescent probe was designed. The environment-friendly, simple, rapid, selective and sensitive fluorescent probe has been utilized to detect Cu(2+) in hair and tap water samples and it achieved consistent results with those obtained by inductively coupled plasma mass spectroscopy (ICP-MS). The mechanism of the proposed assay for the detection of Cu(2+) is discussed.
Wang, Hong; Zhang, Peisheng; Tian, Yong; Zhang, Yuan; Yang, Heping; Chen, Shu; Zeng, Rongjin; Long, Yunfei; Chen, Jian
2018-04-30
A simple and readily available fluorescent probe is needed for the real-time monitoring of endogenous cysteine (Cys) levels in living cells, as such a probe could be used to study the role of Cys in related diseases. Herein, we report the first fluorescent probe based on carbon dots (CDs-FITA) for the selective and ratiometric imaging of endogenous Cys in live cells. In this ratiometric fluorescent probe, a fluorescein derivative (FITA) that recognizes Cys is covalently linked to the surfaces of carbon dots (CDs); employing CDs greatly improves the water solubility of the probe. Acrylate on FITA is selectively cleaved by Cys in aqueous solution under mild conditions, leading to a dramatic increase in the fluorescence from fluorescein. The probe therefore allows the highly selective ratiometric fluorescent detection of Cys even in the presence of various interferents. The as-prepared CDs-FITA showed excellent performance when applied to detect Cys in blood serum. In addition, due to its negligible cytotoxicity, the CDs-FITA can also be utilized for the real-time monitoring of endogenous cysteine (Cys) levels in living cells. Graphical abstract Illustration of the CD-based probe for Cys imaging in living cells.
Ultra-small dye-doped silica nanoparticles via modified sol-gel technique
NASA Astrophysics Data System (ADS)
Riccò, R.; Nizzero, S.; Penna, E.; Meneghello, A.; Cretaio, E.; Enrichi, F.
2018-05-01
In modern biosensing and imaging, fluorescence-based methods constitute the most diffused approach to achieve optimal detection of analytes, both in solution and on the single-particle level. Despite the huge progresses made in recent decades in the development of plasmonic biosensors and label-free sensing techniques, fluorescent molecules remain the most commonly used contrast agents to date for commercial imaging and detection methods. However, they exhibit low stability, can be difficult to functionalise, and often result in a low signal-to-noise ratio. Thus, embedding fluorescent probes into robust and bio-compatible materials, such as silica nanoparticles, can substantially enhance the detection limit and dramatically increase the sensitivity. In this work, ultra-small fluorescent silica nanoparticles (NPs) for optical biosensing applications were doped with a fluorescent dye, using simple water-based sol-gel approaches based on the classical Stöber procedure. By systematically modulating reaction parameters, controllable size tuning of particle diameters as low as 10 nm was achieved. Particles morphology and optical response were evaluated showing a possible single-molecule behaviour, without employing microemulsion methods to achieve similar results. [Figure not available: see fulltext.
Kurata, Shinya; Kanagawa, Takahiro; Yamada, Kazutaka; Torimura, Masaki; Yokomaku, Toyokazu; Kamagata, Yoichi; Kurane, Ryuichiro
2001-01-01
We have developed a simple method for the quantitative detection of specific DNA or RNA molecules based on the finding that BODIPY® FL fluorescence was quenched by its interaction with a uniquely positioned guanine. This approach makes use of an oligonucleotide probe or primer containing a BODIPY® FL-modified cytosine at its 5′-end. When such a probe was hybridized with a target DNA, its fluorescence was quenched by the guanine in the target, complementary to the modified cytosine, and the quench rate was proportional to the amount of target DNA. This widely applicable technique will be used directly with larger samples or in conjunction with the polymerase chain reaction to quantify small DNA samples. PMID:11239011
Lu, Linlin; Feng, Chongchong; Xu, Jie; Wang, Fengyang; Yu, Haijun; Xu, Zhiai; Zhang, Wen
2017-06-15
Copper is closely related to liver damage, therefore, it is essential to develop a simple and sensitive strategy to detect copper ions (Cu 2+ ) in liver cells. A hydrophobic carbon dots (HCDs)-based dual-emission fluorescent probe for Cu 2+ was prepared by encapsulating HCDs in micelles formed by self-assembly of amphiphilic polymer DSPE-PEG and tetrakis (4-carboxyphenyl) porphyrin (TCPP)-modified DSPE-PEG. The obtained probe showed characteristic fluorescence emissions of HCDs and TCPP with large emission shift of 170nm with single-wavelength excitation. In the presence of Cu 2+ , the fluorescence of TCPP was quenched and that of HCDs remained unchanged, displaying ratiometric fluorescence response to Cu 2+ . The developed probe exhibited high sensitivity (detection limit down to 36nM) and selectivity to Cu 2+ over other substances, and the probe was used to image the changes of Cu 2+ level in liver cells successfully. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Feng; Li, Hongren; Cui, Tianfang
2017-11-01
Fluorescent carbon-based nanomaterials(CNs) with tunable visible emission are biocompatible, environment friendly and most suitable for various biomedical applications. Despite the successes in preparing strongly fluorescent CNs, preserving the luminescence in solid materials is still challenging because of the serious emission quenching of CNs in solid state materials. In this work, fluorescent carbon and silica nanohybrids (SiCNHs) were synthesized via a simple one-step hydrothermal approach by carbonizing sodium citrate and (3-aminopropyl)triethoxysilane(APTES), and hydrolysis of tetraethyl orthosilicate(TEOS). The resultant SiCNs were characterized through X-ray diffraction (XRD), transmission electron microscopy (TEM), FT-IR, X-ray photoelectron spectroscopy (XPS), and photoluminescence (PL) spectroscopy. The SiCNs exhibited strong fluorescence in both aqueous and solid states. The luminescent solid state SiCNs power were successfully used as a fluorescent labeling material for enhanced imaging of latent fingerprints(LFPs) on single background colour and multi-coloured surfaces substrates in forensic science for individual identification.
A fluorescent aptasensor for sensitive analysis oxytetracycline based on silver nanoclusters.
Hosseini, Morteza; Mehrabi, Fatemeh; Ganjali, Mohammad Reza; Norouzi, Parviz
2016-11-01
A fluorescent aptasensor for detection of oxytetracycline (OTC) was presented based on fluorescence quenching of DNA aptamer-templated silver nanoclusters (AgNCs). The specific DNA scaffolds with two different nucleotides fragments were used: one was enriched with a cytosine sequence fragment (C12) that could produce DNA-AgNCs via a chemical reduction method, and another was the OTC aptamer fragment that could selectively bind to the OTC antibiotic. Thus, the as-prepared AgNCs could exhibit quenched fluorescence after binding to the target OTC. The fluorescence ratio of the DNA-AgNCs was quenched in a linearly proportional manner to the concentration of the target in the range of 0.5 nM to 100 nM with a detection limit of 0.1 nM. This proposed nanobiosensor was demonstrated to be sensitive, selective, and simple, introducing a viable alternative for rapid determination of toxin OTC in honey and water samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Nonmydriatic fluorescence-based quantitative imaging of human macular pigment distributions
NASA Astrophysics Data System (ADS)
Sharifzadeh, Mohsen; Bernstein, Paul S.; Gellermann, Werner
2006-10-01
We have developed a CCD-camera-based nonmydriatic instrument that detects fluorescence from retinal lipofuscin chromophores ("autofluorescence") as a means to indirectly quantify and spatially image the distribution of macular pigment (MP). The lipofuscin fluorescence intensity is reduced at all retinal locations containing MP, since MP has a competing absorption in the blue-green wavelength region. Projecting a large diameter, 488 nm excitation spot onto the retina, centered on the fovea, but extending into the macular periphery, and comparing lipofuscin fluorescence intensities outside and inside the foveal area, it is possible to spatially map out the distribution of MP. Spectrally selective detection of the lipofuscin fluorescence reveals an important wavelength dependence of the obtainable image contrast and deduced MP optical density levels, showing that it is important to block out interfering fluorescence contributions in the detection setup originating from ocular media such as the lens. Measuring 70 healthy human volunteer subjects with no ocular pathologies, we find widely varying spatial extent of MP, distinctly differing distribution patterns of MP, and strongly differing absolute MP levels among individuals. Our population study suggests that MP imaging based on lipofuscin fluorescence is useful as a relatively simple, objective, and quantitative noninvasive optical technique suitable to rapidly screen MP levels and distributions in healthy humans with undilated pupils.
An aptamer-based fluorescence bio-sensor for chiral recognition of arginine enantiomers.
Yuan, Haiyan; Huang, Yunmei; Yang, Jidong; Guo, Yuan; Zeng, Xiaoqing; Zhou, Shang; Cheng, Jiawei; Zhang, Yuhui
2018-07-05
In this study, a novel aptamer - based fluorescence bio-sensor (aptamer-AuNps) was developed for chiral recognition of arginine (Arg) enantiomers based on aptamer and gold nanoparticles (AuNps). Carboxyfluorescein (FAM) labeled aptamers (Apt) were absorbed on AuNps and their fluorescence intensity could be significantly quenched by AuNps based on fluorescence resonance energy transfer (FRET). Once d-Arg or l-Arg were added into the above solution, the aptamer specifically bind to Arg enantiomers and released from AuNps, so the fluorescence intensity of d-Arg system and l-Arg system were all enhanced. The affinity of Apt to l-Arg is tighter to d-Arg, so the enhanced fluorescence signals of l-Arg system was stronger than d-Arg system. What's more, the enhanced fluorescence were directly proportional to the concentration of d-Arg and l-Arg ranging from 0-300 nM and 0-400 nM with related coefficients of 0.9939 and 0.9952, respectively. Furthermore, the method was successfully applied to detection l-Arg in human urine samples with satisfactory results. Eventually, a simple "OR" logic gate with d-Arg &l-Arg as inputs and AuNps aggregation state as outputs was fabricated, which can help us understand the chiral recognition process deeply. Copyright © 2018 Elsevier B.V. All rights reserved.
Fluorescence tomography characterization for sub-surface imaging with protoporphyrin IX
Kepshire, Dax; Davis, Scott C.; Dehghani, Hamid; Paulsen, Keith D.; Pogue, Brian W.
2009-01-01
Optical imaging of fluorescent objects embedded in a tissue simulating medium was characterized using non-contact based approaches to fluorescence remittance imaging (FRI) and sub-surface fluorescence diffuse optical tomography (FDOT). Using Protoporphyrin IX as a fluorescent agent, experiments were performed on tissue phantoms comprised of typical in-vivo tumor to normal tissue contrast ratios, ranging from 3.5:1 up to 10:1. It was found that tomographic imaging was able to recover interior inclusions with high contrast relative to the background; however, simple planar fluorescence imaging provided a superior contrast to noise ratio. Overall, FRI performed optimally when the object was located on or close to the surface and, perhaps most importantly, FDOT was able to recover specific depth information about the location of embedded regions. The results indicate that an optimal system for localizing embedded fluorescent regions should combine fluorescence reflectance imaging for high sensitivity and sub-surface tomography for depth detection, thereby allowing more accurate localization in all three directions within the tissue. PMID:18545571
A virus-MIPs fluorescent sensor based on FRET for highly sensitive detection of JEV.
Liang, Caishuang; Wang, Huan; He, Kui; Chen, Chunyan; Chen, Xiaoming; Gong, Hang; Cai, Changqun
2016-11-01
Major stumbling blocks in the recognition and detection of virus are the unstable biological recognition element or the complex detection means. Here a fluorescent sensor based on virus-molecular imprinted polymers (virus-MIPs) was designed for specific recognition and highly sensitive detection of Japanese encephalitis virus (JEV). The virus-MIPs were anchored on the surface of silica microspheres modified by fluorescent dye, pyrene-1-carboxaldehyde (PC). The fluorescence intensity of PC can be enhanced by the principle of fluorescence resonance energy transfer (FRET), where virus acted as energy donor and PC acted as energy acceptor. The enhanced fluorescence intensity was proportional to the concentration of virus in the range of 24-960pM, with a limit of detection (LOD, 3σ) of 9.6pM, and the relative standard deviation was 1.99%. In additional, the specificity study confirmed the resultant MIPs has high-selectivity for JEV. This sensor would become a new key for the detection of virus because of its high sensitive, simple operation, high stability and low cost. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
He, Lijun; Zhang, Heng; Fan, Huanhuan; Jiang, Xiuming; Zhao, Wenjie; Xiang, Guo Qiang
2018-01-01
Herein, we propose a simple and effective strategy for designing a ratiometric fluorescent nanosensor. We designed and developed a carbon dots (CDs) based dual-emission nanosensor for vanadium(V) by coating the surface of dye-doped silica nanoparticles with CDs. The fluorescence of dual-emission silica nanoparticles was quenched in acetic acid through potassium bromate (KBrO3) oxidation. V(V) could catalyze KBrO3 oxidation reaction process, resulting in the ratiometric fluorescence quenching of dual-emission silica nanoparticles. We investigated several important parameters affecting the performance of the nanosensor. Under the optimized conditions, the detection limit of this nanosensor reached 1.1 ng mL- 1 and the linear range from 10 to 800 ng mL- 1. Furthermore, we found that the sensor was suitable for determination of V(V) in different mineral water samples with satisfactory results.
Fluorescent sensors based on boronic acids
NASA Astrophysics Data System (ADS)
Cooper, Christopher R.; James, Tony D.
1999-05-01
Sensor systems have long been needed for detecting the presence in solution of certain chemically or biologically important species. Sensors are used in a wide range of applications from simple litmus paper that shows a single color change in acidic or basic environments to complex biological assays that use enzymes, antibodies and antigens to display binding events. With this work the use of boronic acids in the design and synthesis of sensors for saccharides (diols) will be presented. The fluorescent sensory systems rely on photoinduced electron transfer (PET) to modulate the observed fluorescence. When saccharides form cyclic boronate esters with boronic acids, the Lewis acidity of the boronic acid is enhanced and therefore the Lewis acid-base interaction between the boronic acid and a neighboring amine is strengthened. The strength of this acid-base interaction modulates the PET from the amine (acting as a quencher) to anthracene (acting as a fluorophore). These compounds show increased fluorescence at neutral pH through suppression of the PET from nitrogen to anthracene on saccharide binding. The general strategy for the development of saccharide selective systems will be discussed. The potential of the boronic acid based systems will be illustrated using the development of glucose and glucosamine selective fluorescent sensors as examples.
Exploring the Dynamics of Cell Processes through Simulations of Fluorescence Microscopy Experiments
Angiolini, Juan; Plachta, Nicolas; Mocskos, Esteban; Levi, Valeria
2015-01-01
Fluorescence correlation spectroscopy (FCS) methods are powerful tools for unveiling the dynamical organization of cells. For simple cases, such as molecules passively moving in a homogeneous media, FCS analysis yields analytical functions that can be fitted to the experimental data to recover the phenomenological rate parameters. Unfortunately, many dynamical processes in cells do not follow these simple models, and in many instances it is not possible to obtain an analytical function through a theoretical analysis of a more complex model. In such cases, experimental analysis can be combined with Monte Carlo simulations to aid in interpretation of the data. In response to this need, we developed a method called FERNET (Fluorescence Emission Recipes and Numerical routines Toolkit) based on Monte Carlo simulations and the MCell-Blender platform, which was designed to treat the reaction-diffusion problem under realistic scenarios. This method enables us to set complex geometries of the simulation space, distribute molecules among different compartments, and define interspecies reactions with selected kinetic constants, diffusion coefficients, and species brightness. We apply this method to simulate single- and multiple-point FCS, photon-counting histogram analysis, raster image correlation spectroscopy, and two-color fluorescence cross-correlation spectroscopy. We believe that this new program could be very useful for predicting and understanding the output of fluorescence microscopy experiments. PMID:26039162
Liu, Kai; Zhao, Xiaojun; Liu, Qingxiang; Huo, Jianzhong; Wang, Xing; Wu, Yanping
2015-04-05
A simple, highly selective and sensitive chemosensor (E)-2-((quinolin-8-ylimino) methyl) phenol (QP) has been developed for the fluoride, as demonstrated by the photophysical properties obtained by UV-vis and fluorescent methods. Excited-state inter/intramolecular proton transfer (ESPT) was suggested to be responsible for the fluoride-induced 'turn on' fluorescence and the blue shift of 25 nm in the emission spectrum. Copyright © 2014 Elsevier B.V. All rights reserved.
Application of CdSe quantum dots for the direct detection of TNT.
Yi, Kui-Yu
2016-02-01
CdSe quantum dots were synthesized through a simple, green organic-phase method. Paraffin was used as the reaction solvent and a reducing agent, oleic acid was the reaction ligand, and oleyl amine was the stabilizer. Based on the phenomenon of TNT quenched oil-soluble CdSe quantum dot fluorescence, a simple, fast, and direct method of TNT detection was established. Under optimum conditions, the degree of fluorescence quenching of oil-soluble CdSe quantum dots had a good linear correlation with TNT concentration in the 1.0×10(-7)-5.0×10(-5) mol/L range, and the correlation coefficient was 0.9990. TNT detection limit was 2.1×10(-8)mol/L. The method was successfully used to determine TNT-explosion dust samples, results were satisfactory. The fluorescence quenching mechanism of oil-soluble CdSe quantum dots by TNT was also discussed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Ho Won; Lee, Ki-Heon; Lee, Jae Woo; Kim, Jong-Hoon; Yang, Heesun; Kim, Young Kwan
2015-02-01
In this work, the simple process of hybrid quantum dot (QD)/organic light-emitting diode (OLED) was proposed to apply a white illumination light by using QD plate and organic fluorescence. Conventional blue fluorescent OLEDs were firstly fabricated and then QD plates of various concentrations, which can be controlled of UV-vis absorption and photoluminescence spectrum, were attached under glass substrate of completed blue devices. The suggested process indicates that we could fabricate the white device through very simple process without any deposition of orange or red organic emitters. Therefore, this work would be demonstrated that the potential simple process for white applications can be applied and also can be extended to additional research on light applications.
A cell-surface-anchored ratiometric fluorescent probe for extracellular pH sensing.
Ke, Guoliang; Zhu, Zhi; Wang, Wei; Zou, Yuan; Guan, Zhichao; Jia, Shasha; Zhang, Huimin; Wu, Xuemeng; Yang, Chaoyong James
2014-09-10
Accurate sensing of the extracellular pH is a very important yet challenging task in biological and clinical applications. This paper describes the development of an amphiphilic lipid-DNA molecule as a simple yet useful cell-surface-anchored ratiometric fluorescent probe for extracellular pH sensing. The lipid-DNA probe, which consists of a hydrophobic diacyllipid tail and a hydrophilic DNA strand, is modified with two fluorescent dyes; one is pH-sensitive as pH indicator and the other is pH-insensitive as an internal reference. The lipid-DNA probe showed sensitive and reversible response to pH change in the range of 6.0-8.0, which is suitable for most extracellular studies. In addition, based on simple hydrophobic interactions with the cell membrane, the lipid-DNA probe can be easily anchored on the cell surface with negligible cytotoxicity, excellent stability, and unique ratiometric readout, thus ensuring its accurate sensing of extracellular pH. Finally, this lipid-DNA-based ratiometric pH indicator was successfully used for extracellular pH sensing of cells in 3D culture environment, demonstrating the potential applications of the sensor in biological and medical studies.
NASA Astrophysics Data System (ADS)
Jha, Gaurav; Roy, Subhasis; Sahu, Prabhat Kumar; Banerjee, Somnath; Anoop, N.; Rahaman, Abdur; Sarkar, Moloy
2018-01-01
Keeping in mind the advantages of material-based systems over simple molecule-based systems, we have designed and developed three inorganic-organic hybrid systems by anchoring 1,8-naphthalimide derivatives to mesoporous silica nanoparticles for detection of free radicals. Prior to photophysical study, systems are characterized by spectroscopic, microscopic and thermo-gravimetric techniques. Steady state and time-resolved fluorescence studies demonstrate that the hydrazine based system is senstive towards detection of various free radicals. Cellular imaging study reveals cell permeability and toxicity study demonstrates the non-toxic nature of the material. These studies have suggested that present system has the potential to be used in various biological applications.
A Label-Free Aptasensor for Ochratoxin a Detection Based on the Structure Switch of Aptamer.
Liu, Feng; Ding, Ailing; Zheng, Jiushang; Chen, Jiucun; Wang, Bin
2018-06-01
A label-free sensing platform is developed based on switching the structure of aptamer for highly sensitive and selective fluorescence detection of ochratoxin A (OTA). OTA induces the structure of aptamer, transforms into G-quadruplex and produces strong fluorescence in the presence of zinc(II)-protoporphyrin IX probe due to the specific bind to G-quadruplex. The simple method exhibits high sensitivity towards OTA with a detection limit of 0.03 nM and excellent selectivity over other mycotoxins. In addition, the successful detection of OTA in real samples represents a promising application in food safety.
Acoustically levitated droplets: a contactless sampling method for fluorescence studies.
Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich
2008-01-01
Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.
NASA Astrophysics Data System (ADS)
Sun, Jessica; Miller, Jessica P.; Hathi, Deep; Zhou, Haiying; Achilefu, Samuel; Shokeen, Monica; Akers, Walter J.
2016-08-01
Fluorescence imaging, in combination with tumor-avid near-infrared (NIR) fluorescent molecular probes, provides high specificity and sensitivity for cancer detection in preclinical animal models, and more recently, assistance during oncologic surgery. However, conventional camera-based fluorescence imaging techniques are heavily surface-weighted such that surface reflection from skin or other nontumor tissue and nonspecific fluorescence signals dominate, obscuring true cancer-specific signals and blurring tumor boundaries. To address this challenge, we applied structured illumination fluorescence molecular imaging (SIFMI) in live animals for automated subtraction of nonspecific surface signals to better delineate accumulation of an NIR fluorescent probe targeting α4β1 integrin in mice bearing subcutaneous plasma cell xenografts. SIFMI demonstrated a fivefold improvement in tumor-to-background contrast when compared with other full-field fluorescence imaging methods and required significantly reduced scanning time compared with diffuse optical spectroscopy imaging. Furthermore, the spatial gradient mapping enhanced highlighting of tumor boundaries. Through the relatively simple hardware and software modifications described, SIFMI can be integrated with clinical fluorescence imaging systems, enhancing intraoperative tumor boundary delineation from the uninvolved tissue.
NASA Astrophysics Data System (ADS)
Tan, Juntao; Yang, Nuo; Hu, Zixi; Su, Jing; Zhong, Jianhong; Yang, Yang; Yu, Yating; Zhu, Jianmeng; Xue, Dabin; Huang, Yingying; Lai, Zongqiang; Huang, Yong; Lu, Xiaoling; Zhao, Yongxiang
2016-06-01
A simple, highly sensitive method to detect leukemia cells has been developed based on aptamer-modified fluorescent silica nanoparticles (FSNPs). In this strategy, the amine-labeled Sgc8 aptamer was conjugated to carboxyl-modified FSNPs via amide coupling between amino and carboxyl groups. Sensitivity and specificity of Sgc8-FSNPs were assessed using flow cytometry and fluorescence microscopy. These results showed that Sgc8-FSNPs detected leukemia cells with high sensitivity and specificity. Aptamer-modified FSNPs hold promise for sensitive and specific detection of leukemia cells. Changing the aptamer may allow the FSNPs to detect other types of cancer cells.
Wang, Jian; Zhang, Yanjun; Ye, Jiqing; Jiang, Zhou
2017-06-01
When excited at 435 nm, tetra-sulfonate zinc phthalocyanine (ZnPcS 4 ) emitted dual fluorescence at 495 and 702 nm. The abnormal fluorescence at 495 nm was experimentally studied and analyzed in detail for the first time. The abnormal fluorescence at 495 nm was deduced to originate from triplet-triplet (T-T) energy transfer of excited phthalocyanine ( 3 *ZnPcS 4 ). Furthermore, graphene quantum dots (GQDs) enhanced the 495 nm fluorescence quantum yield (Q) of ZnPcS 4 . The fluorescence properties of ZnPcS 4 -GQDs conjugate were retained in a cellular environment. Based on the fluorescence of ZnPcS 4 -GQDs conjugate, we designed and prepared an Apt29/thrombin/Apt15 sandwich thrombin sensor with high specificity and affinity. This cost-saving, simple operational sensing strategy can be extended to use in sensing/imaging of other biomolecules. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Ceylan Koydemir, Hatice; Gorocs, Zoltan; McLeod, Euan; Tseng, Derek; Ozcan, Aydogan
2015-03-01
Giardia lamblia is a waterborne parasite that causes an intestinal infection, known as giardiasis, and it is found not only in countries with inadequate sanitation and unsafe water but also streams and lakes of developed countries. Simple, sensitive, and rapid detection of this pathogen is important for monitoring of drinking water. Here we present a cost-effective and field portable mobile-phone based fluorescence microscopy platform designed for automated detection of Giardia lamblia cysts in large volume water samples (i.e., 10 ml) to be used in low-resource field settings. This fluorescence microscope is integrated with a disposable water-sampling cassette, which is based on a flow-through porous polycarbonate membrane and provides a wide surface area for fluorescence imaging and enumeration of the captured Giardia cysts on the membrane. Water sample of interest, containing fluorescently labeled Giardia cysts, is introduced into the absorbent pads that are in contact with the membrane in the cassette by capillary action, which eliminates the need for electrically driven flow for sample processing. Our fluorescence microscope weighs ~170 grams in total and has all the components of a regular microscope, capable of detecting individual fluorescently labeled cysts under light-emitting-diode (LED) based excitation. Including all the sample preparation, labeling and imaging steps, the entire measurement takes less than one hour for a sample volume of 10 ml. This mobile phone based compact and cost-effective fluorescent imaging platform together with its machine learning based cyst counting interface is easy to use and can even work in resource limited and field settings for spatio-temporal monitoring of water quality.
Radiative decay engineering 5: metal-enhanced fluorescence and plasmon emission
Lakowicz, Joseph R.
2009-01-01
Metallic particles and surfaces display diverse and complex optical properties. Examples include the intense colors of noble metal colloids, surface plasmon resonance absorption by thin metal films, and quenching of excited fluorophores near the metal surfaces. Recently, the interactions of fluorophores with metallic particles and surfaces (metals) have been used to obtain increased fluorescence intensities, to develop assays based on fluorescence quenching by gold colloids, and to obtain directional radiation from fluorophores near thin metal films. For metal-enhanced fluorescence it is difficult to predict whether a particular metal structure, such as a colloid, fractal, or continuous surface, will quench or enhance fluorescence. In the present report we suggest how the effects of metals on fluorescence can be explained using a simple concept, based on radiating plasmons (RPs). The underlying physics may be complex but the concept is simple to understand. According to the RP model, the emission or quenching of a fluorophore near the metal can be predicted from the optical properties of the metal structures as calculated from electrodynamics, Mie theory, and/or Maxwell’s equations. For example, according to Mie theory and the size and shape of the particle, the extinction of metal colloids can be due to either absorption or scattering. Incident energy is dissipated by absorption. Far-field radiation is created by scattering. Based on our model small colloids are expected to quench fluorescence because absorption is dominant over scattering. Larger colloids are expected to enhance fluorescence because the scattering component is dominant over absorption. The ability of a metal’s surface to absorb or reflect light is due to wavenumber matching requirements at the metal–sample interface. Wavenumber matching considerations can also be used to predict whether fluorophores at a given distance from a continuous planar surface will be emitted or quenched. These considerations suggest that the so called “lossy surface waves” which quench fluorescence are due to induced electron oscillations which cannot radiate to the far-field because wavevector matching is not possible. We suggest that the energy from the fluorophores thought to be lost by lossy surface waves can be recovered as emission by adjustment of the sample to allow wavevector matching. The RP model provides a rational approach for designing fluorophore–metal configurations with the desired emissive properties and a basis for nanophotonic fluorophore technology. PMID:15691498
Sun, Tao; Niu, Qingfen; Li, Tianduo; Guo, Zongrang; Liu, Haixia
2018-01-05
A simple, reversible, colorimetric and water-soluble fluorescent chemosensor ADA for the naked-eye detection of Cu 2+ was developed. Sensor ADA showed high selectivity and sensitivity toward Cu 2+ in ~100% aqueous media over wide pH range. Sensor ADA exhibited a red-shift in the absorption spectra from 466 to 480nm that is accompanied by significant color change from light yellow to yellowish brown instantaneously. The Cu 2+ recognition is based on the chelation-enhanced fluorescence quenching (CHEQ) effect of the paramagnetic nature. The lowest detection limit is determined to be 15.8nM, which is much lower than the allowable level of Cu 2+ in drinking water set by U.S. Environmental Protection Agency (~20μM) and the World Health Organization (~30μM). The 1:1 binding process was confirmed by fluorescence measurements, IR analysis and DFT studies. Moreover, sensor ADA was successfully applied for determination of trace level of Cu 2+ with 4 reuse cycles in various water samples, which affords promising potential in ion-detection field. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sun, Tao; Niu, Qingfen; Li, Tianduo; Guo, Zongrang; Liu, Haixia
2018-01-01
A simple, reversible, colorimetric and water-soluble fluorescent chemosensor ADA for the naked-eye detection of Cu2 + was developed. Sensor ADA showed high selectivity and sensitivity toward Cu2 + in 100% aqueous media over wide pH range. Sensor ADA exhibited a red-shift in the absorption spectra from 466 to 480 nm that is accompanied by significant color change from light yellow to yellowish brown instantaneously. The Cu2 + recognition is based on the chelation-enhanced fluorescence quenching (CHEQ) effect of the paramagnetic nature. The lowest detection limit is determined to be 15.8 nM, which is much lower than the allowable level of Cu2 + in drinking water set by U.S. Environmental Protection Agency ( 20 μM) and the World Health Organization ( 30 μM). The 1:1 binding process was confirmed by fluorescence measurements, IR analysis and DFT studies. Moreover, sensor ADA was successfully applied for determination of trace level of Cu2 + with 4 reuse cycles in various water samples, which affords promising potential in ion-detection field.
Glutathione-capped CdTe nanocrystals as probe for the determination of fenbendazole
NASA Astrophysics Data System (ADS)
Li, Qin; Tan, Xuanping; Li, Jin; Pan, Li; Liu, Xiaorong
2015-04-01
Water-soluble glutathione (GSH)-capped CdTe quantum dots (QDs) were synthesized. In pH 7.1 PBS buffer solution, the interaction between GSH-capped CdTe QDs and fenbendazole (FBZ) was investigated by spectroscopic methods, including fluorescence spectroscopy, ultraviolet-visible absorption spectroscopy, and resonance Rayleigh scattering (RRS) spectroscopy. In GSH-capped CdTe QDs solution, the addition of FBZ results in the fluorescence quenching and RRS enhancement of GSH-capped CdTe QDs. And the quenching intensity (enhanced RRS intensity) was proportional to the concentration of FBZ in a certain range. Investigation of the interaction mechanism, proved that the fluorescence quenching and RRS enhancement of GSH-capped CdTe QDs by FBZ is the result of electrostatic attraction. Based on the quenching of fluorescence (enhancement of RRS) of GSH-capped CdTe QDs by FBZ, a novel, simple, rapid and specific method for FBZ determination was proposed. The detection limit for FBZ was 42 ng mL-1 (3.4 ng mL-1) and the quantitative determination range was 0-2.8 μg mL-1 with a correlation of 0.9985 (0.9979). The method has been applied to detect FBZ in real simples and with satisfactory results.
Choi, Yujin; Jo, Seongho; Chae, Ari; Kim, Young Kwang; Park, Jeong Eun; Lim, Donggun; Park, Sung Young; In, Insik
2017-08-23
Highly fluorescent and amphiphilic carbon quantum dots (CQDs) were prepared by microwave-assisted pyrolysis of citric acid and 4,7,10-trioxa-1,13-tridecanediamine (TTDDA), which functioned as an A 3 and B 2 polyamidation type monomer set. Gram quantities of fluorescent CQDs were easily obtained within 5 min of microwave heating using a household microwave oven. Because of the dual role of TTDDA, both as a constituting monomer and as a surface passivation agent, TTDDA-based CQDs showed a high fluorescence quantum yield of 29% and amphiphilic solubility in various polar and nonpolar solvents. These properties enable the wide application of TTDDA-based CQDs as nontoxic bioimaging agents, nanofillers for polymer composites, and down-converting layers for enhancing the efficiency of Si solar cells.
Single particle fluorescence: a simple experimental approach to evaluate coincidence effects.
Wu, Xihong; Omenetto, Nicoló; Smith, Benjamin W; Winefordner, James D
2007-07-01
Real-time characterization of the chemical and physical properties of individual aerosol particles is an important issue in environmental studies. A well-established way of accomplishing this task relies on the use of laser-induced fluorescence or laser ionization mass spectrometry. We describe here a simple approach aimed at experimentally verifying that single particles are indeed addressed. The approach has been tested with a system consisting of a series of aerodynamic lenses to form a beam of dye-doped particles aerosolized from a solution of known concentration with a medical nebulizer. Two independent spectral detection channels simultaneously measure the fluorescence signals generated in two different spectral regions by the passage of a mixture of two dye-doped particles through a focused laser beam in a vacuum chamber. Coincidence effects, arising from the simultaneous observation of both fluorescence emissions, can then be directly observed. Both dual-color fluorescence and pulse height distribution have been analyzed. As expected, the probability of single- or multiple-particle interaction strongly depends on the particle flux in the chamber, which is related to the concentration of particles in the nebulized solution. In our case, to achieve a two-particle coincidence smaller than 10%, a particle concentration lower than 1.2x10(5) particles/mL is required. Moreover, it was found that the experimental observations are in agreement with a simple mathematical model based on Poisson statistics. Although the results obtained refer to particle concentrations in solution, our approach can equally be applicable to experiments involving direct air sampling, provided that the number density of particles in air can be measured a priori, e.g., with a particle counter.
Liu, Xiao-Ke; Chen, Zhan; Qing, Jian; Zhang, Wen-Jun; Wu, Bo; Tam, Hoi Lam; Zhu, Furong; Zhang, Xiao-Hong; Lee, Chun-Sing
2015-11-25
A high-performance hybrid white organic light-emitting device (WOLED) is demonstrated based on an efficient novel thermally activated delayed fluorescence (TADF) blue exciplex system. This device shows a low turn-on voltage of 2.5 V and maximum forward-viewing external quantum efficiency of 25.5%, which opens a new avenue for achieving high-performance hybrid WOLEDs with simple structures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wei, Wei; Gao, Chunyan; Xiong, Yanxiang; Zhang, Yuanjian; Liu, Songqin; Pu, Yuepu
2015-01-01
DNA methylation plays an important role in many biological events and is associated with various diseases. Most traditional methods for detection of DNA methylation are based on the complex and expensive bisulfite method. In this paper, we report a novel fluorescence method to detect DNA and DNA methylation based on graphene oxide (GO) and restriction endonuclease HpaII. The skillfully designed probe DNA labeled with 5-carboxyfluorescein (FAM) and optimized GO concentration keep the probe/target DNA still adsorbed on the GO. After the cleavage action of HpaII the labeled FAM is released from the GO surface and its fluorescence recovers, which could be used to detect DNA in the linear range of 50 pM-50 nM with a detection limit of 43 pM. DNA methylation induced by transmethylase (Mtase) or other chemical reagents prevents HpaII from recognizing and cleaving the specific site; as a result, fluorescence cannot recover. The fluorescence recovery efficiency is closely related to the DNA methylation level, which can be used to detect DNA methylation by comparing it with the fluorescence in the presence of intact target DNA. The method for detection of DNA and DNA methylation is simple, reliable and accurate. Copyright © 2014 Elsevier B.V. All rights reserved.
Rapid and sensitive detection of ketamine in blood using novel fluorescence genosensor.
Ding, Yanjun; Li, Xingmei; Guo, Yadong; Yan, Jie; Ling, Jiang; Li, Weichen; Lan, Lingmei; Chang, Yunfeng; Cai, Jifeng; Zha, Lagabaiyla
2017-12-01
In recent years, drug abuse has been considered as a most challenging social problem that aroused public attention. Ketamine has increased in unregulated use as a 'recreational drug' in teenagers. However, there is no suitable and maneuverable detection method for ketamine in situ at the moment. Fluorescence sensor technique, with predominant recognition and simple operation, is a good potential application in drug detection. Here, we first reported a highly sensitive and selective fluorescence genosensor for rapid detection of ketamine based on DNA-templated silver nanoclusters (DNA-AgNCs) probes, in which the DNA sequence could specially recognize ketamine with high affinity. Parameters affecting detection efficiency were investigated and optimized. Under optimum conditions, the as-prepared genosensor can allow for the determination of ketamine in the concentration range of 0.0001-20 μg/mL with two linear equations: one is y = 2.84x-7.139 (R 2 = 0.987) for 0.0001-0.1 μg/mL, and the other is y = 1.87x-0.091 (R 2 = 0.962) for 0.1-20 μg/mL, and the estimated detection limit of ketamine is 0.06 ng/mL. Moreover, the feasibility of this proposed method was also demonstrated by analyzing forensic blood samples. Compared with official gas chromatography/mass spectrometry (GC/MS), this fluorescence genosensor is simple, rapid, and accurate for quantitative determination of ketamine in blood for pharmaceutical and forensic analysis. Overall, it is the first report on a fluorescence genosensor for detecting ketamine directly in blood. This research may provide a new insight for the analyst to band fluorescence genosensor technology together with drug monitoring in the battle against drug abuse and forensic examination. Graphical abstract High selectively detection of ketamine using a novel fluorescence genosensor based on DNA-AgNCs probe.
Yan, Xu; Li, Hongxia; Han, Xiaosong; Su, Xingguang
2015-12-15
In this work, we develop a novel and sensitive sensor for the detection of organophosphorus pesticides based on the inner-filter effect (IFE) between gold nanoparticles (AuNPs) and ratiometric fluorescent quantum dots (RF-QDs). The RF-QDs has been designed by hybridizing two differently colored CdTe QDs, in which the red emissive QDs entrapped in the silica sphere acting as the reference signal, and the green emissive QDs covalently attached on the silica surface serving as the response signal.The fluorescence of RF-QDs could be quenched by AuNPs based on IFE. Protamine could effectively turn on the fluorescence due to the electrostatic attraction between protamine and AuNPs. Trypsin can easily hydrolyze protamine, leading to the quench of the fluorescence. Then, the fluorescence could be recovered again by the addition of parathion-methyl (PM) which could inhibit the activity of trypsin. By measuring the fluorescence of RF-QDs, the inhibition efficiency of PM to trypsin activity was evaluated. Under the optimized conditions, the inhibition efficiency was proportional to the logarithm of PM concentration in the range of 0.04-400 ng mL(-1), with a detection limit of 0.018 ng mL(-1). Furthermore, the simple and convenient method had been used for PM detection in environmental and agricultural samples with satisfactory results. Copyright © 2015 Elsevier B.V. All rights reserved.
Fluorescence turn-on detection of target sequence DNA based on silicon nanodot-mediated quenching.
Zhang, Yanan; Ning, Xinping; Mao, Guobin; Ji, Xinghu; He, Zhike
2018-05-01
We have developed a new enzyme-free method for target sequence DNA detection based on the dynamic quenching of fluorescent silicon nanodots (SiNDs) toward Cy5-tagged DNA probe. Fascinatingly, the water-soluble SiNDs can quench the fluorescence of cyanine (Cy5) in Cy5-tagged DNA probe in homogeneous solution, and the fluorescence of Cy5-tagged DNA probe can be restored in the presence of target sequence DNA (the synthetic target miRNA-27a). Based on this phenomenon, a SiND-featured fluorescent sensor has been constructed for "turn-on" detection of the synthetic target miRNA-27a for the first time. This newly developed approach possesses the merits of low cost, simple design, and convenient operation since no enzymatic reaction, toxic reagents, or separation procedures are involved. The established method achieves a detection limit of 0.16 nM, and the relative standard deviation of this method is 9% (1 nM, n = 5). The linear range is 0.5-20 nM, and the recoveries in spiked human fluids are in the range of 90-122%. This protocol provides a new tactic in the development of the nonenzymic miRNA biosensors and opens a promising avenue for early diagnosis of miRNA-associated disease. Graphical abstract The SiND-based fluorescent sensor for detection of S-miR-27a.
Research of mine water source identification based on LIF technology
NASA Astrophysics Data System (ADS)
Zhou, Mengran; Yan, Pengcheng
2016-09-01
According to the problem that traditional chemical methods to the mine water source identification takes a long time, put forward a method for rapid source identification system of mine water inrush based on the technology of laser induced fluorescence (LIF). Emphatically analyzes the basic principle of LIF technology. The hardware composition of LIF system are analyzed and the related modules were selected. Through the fluorescence experiment with the water samples of coal mine in the LIF system, fluorescence spectra of water samples are got. Traditional water source identification mainly according to the ion concentration representative of the water, but it is hard to analysis the ion concentration of the water from the fluorescence spectra. This paper proposes a simple and practical method of rapid identification of water by fluorescence spectrum, which measure the space distance between unknown water samples and standard samples, and then based on the clustering analysis, the category of the unknown water sample can be get. Water source identification for unknown samples verified the reliability of the LIF system, and solve the problem that the current coal mine can't have a better real-time and online monitoring on water inrush, which is of great significance for coal mine safety in production.
Chip-based wide field-of-view nanoscopy
NASA Astrophysics Data System (ADS)
Diekmann, Robin; Helle, Øystein I.; Øie, Cristina I.; McCourt, Peter; Huser, Thomas R.; Schüttpelz, Mark; Ahluwalia, Balpreet S.
2017-04-01
Present optical nanoscopy techniques use a complex microscope for imaging and a simple glass slide to hold the sample. Here, we demonstrate the inverse: the use of a complex, but mass-producible optical chip, which hosts the sample and provides a waveguide for the illumination source, and a standard low-cost microscope to acquire super-resolved images via two different approaches. Waveguides composed of a material with high refractive-index contrast provide a strong evanescent field that is used for single-molecule switching and fluorescence excitation, thus enabling chip-based single-molecule localization microscopy. Additionally, multimode interference patterns induce spatial fluorescence intensity variations that enable fluctuation-based super-resolution imaging. As chip-based nanoscopy separates the illumination and detection light paths, total-internal-reflection fluorescence excitation is possible over a large field of view, with up to 0.5 mm × 0.5 mm being demonstrated. Using multicolour chip-based nanoscopy, we visualize fenestrations in liver sinusoidal endothelial cells.
Pan, Jiahong; Zheng, Zengyao; Yang, Jianying; Wu, Yaoyu; Lu, Fushen; Chen, Yaowen; Gao, Wenhua
2017-05-01
A novel fluorescence sensor based on controlling the surface passivation degree of carbon quantum dots (CQDs) was developed for glutathione (GSH) detection. First, we found that the fluorescence intensity of the CQDs which was obtained by directly pyrolyzing citric acid would increased largely after the surface passivation treatment by 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC). In the light of this phenomenon, we designed a simple, rapid and selective fluorescence sensor based on the surface passivated CQDs. A certain and excess amount of EDC were mixed with GSH, part of EDC would form a stable complex with GSH owing to the exposed sulfhydryl group of GSH. As the synthesized CQDs were added into the above mixture solution, the fluorescence intensity of the (EDC/GSH)/CQDs mixture solution could be directly related to the amount of GSH. Compared to other fluorescence analytical methods, the fluorescence sensor we design is neither the traditional fluorescent "turn on" probes nor "turn off" probes. It is a new fluorescence analytical method that target object indirectly control the surface passivation degree of CQDs so that it can realize the detection of the target object. Moreover, the proposed method manifested great advantages including short analysis time, low cost and ease of operation. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Zhaodi; Xu, Huajie; Sheng, Liangquan; Chen, Shuisheng; Huang, Deqian; Liu, Jie
2016-03-01
A colorimetric and fluorescent chemosensor (L) for Al(III) was synthesized and fully characterized. L could be both used as a colorimetric and fluorescent chemosensor for the detection of Al3 + ions with low detection limit (8.87 × 10- 7 M) in CH3CN-H2O (1:1, v/v) solution. The binding ratio of L-Al3 + was determined from the Job plot (absorption and fluorescence spectra) and MALDI-TOF MS data to be 1:1. The binding constant (Ka) of Al3 + binding to L was calculated to be 4.8 × 105 M- 1 from a Benesi-Hildebrand plot. Moreover, the binding site of L with Al3 + was determined by 1H NMR titration experiment.
Xiao, Xia; Feng, Ya-Ping; Du, Bin; Sun, Han-Ru; Ding, You-Quan; Qi, Jian-Guo
2017-03-01
Fluorescent immunolabeling and imaging in free-floating thick (50-60 μm) tissue sections is relatively simple in practice and enables design-based non-biased stereology, or 3-D reconstruction and analysis. This method is widely used for 3-D in situ quantitative biology in many areas of biological research. However, the labeling quality and efficiency of standard protocols for fluorescent immunolabeling of these tissue sections are not always satisfactory. Here, we systematically evaluate the effects of raising the conventional antibody incubation temperatures (4°C or 21°C) to mammalian body temperature (37°C) in these protocols. Our modification significantly enhances the quality (labeling sensitivity, specificity, and homogeneity) and efficiency (antibody concentration and antibody incubation duration) of fluorescent immunolabeling of free-floating thick tissue sections.
NADPH as a potential intrinsic probe for tumour margin estimation
NASA Astrophysics Data System (ADS)
Stewart, Hazel; Hupp, Ted R.; Birch, David J. S.
2018-03-01
The fluorescent properties of the reduced coenzyme NADH and its phosphorylated derivative (NADPH) have been explored in order to assess their potential as an intrinsic probe for cancer surgery. NADPH production is increased in cancer cells to quench reactive oxygen species and meet higher demands for biosynthesis, and has attractive fluorescent properties such as emission towards the visible part of the spectrum and a relatively long fluorescence lifetime upon binding to enzymes ( 1 - 6.5 ns) that helps discriminate against other endogenous species. Different environmental effects on NAD(P)H fluorescence are reported here, including an increase in lifetime upon oxygen removal, an ability to retain its fluorescent properties in a complex medium (a silica phantom) and its fluorescence lifetime also being distinguishable in a cell environment. In addition, the development of a miniaturized liquid light guide filter-based timecorrelated single photon counting fluorescence lifetime system is reported as a step towards time-resolved visual imaging in cancer surgery. This system has been demonstrated as being capable of accurately measuring NAD(P)H fluorescence lifetimes in both simple solvent and cellular environments.
The photoluminescence of a fluorescent lamp: didactic experiments on the exponential decay
NASA Astrophysics Data System (ADS)
Onorato, Pasquale; Gratton, Luigi; Malgieri, Massimiliano; Oss, Stefano
2017-01-01
The lifetimes of the photoluminescent compounds contained in the coating of fluorescent compact lamps are usually measured using specialised instruments, including pulsed lasers and/or spectrofluorometers. Here we discuss how some low cost apparatuses, based on the use of either sensors for the educational lab or commercial digital photo cameras, can be employed to the same aim. The experiments do not require that luminescent phosphors are hazardously extracted from the compact fluorescent lamp, that also contains mercury. We obtain lifetime measurements for specific fluorescent elements of the bulb coating, in good agreement with the known values. We also address the physical mechanisms on which fluorescence lamps are based in a simplified way, suitable for undergraduate students; and we discuss in detail the physics of the lamp switch-off by analysing the time dependent spectrum, measured through a commercial fiber-optic spectrometer. Since the experiment is not hazardous in any way, requires a simple setup up with instruments which are commonly found in educational labs, and focuses on the typical features of the exponential decay, it is suitable for being performed in the undergraduate laboratory.
Determination of adenine based on the fluorescence recovery of the L-Tryptophan-Cu(2+) complex.
Duan, Ruilin; Li, Chunyan; Liu, Shaopu; Liu, Zhongfang; Li, Yuanfang; Yuan, Yusheng; Hu, Xiaoli
2016-01-05
A simple and sensitive method for determination of adenine was developed based on fluorescence quenching and recovery of L-Tryptophan (L-Trp). The fluorescence of L-Trp could efficiently quenched by copper ion compared with other common metal ions. Upon addition of adenine (Ade) in L-Trp-Cu(II) system, the fluorescence was reoccurred. Under the optimum conditions, the recovery fluorescence intensity was linearly correlated with the concentration of adenine in the range from 0.34 to 25.0μmolL(-1), with a correlation coefficient (R(2)) of 0.9994. The detection limit (3σ/k) was 0.046μmolL(-1), indicating that this method could applied to detect trace adenine. In this study, amino acids including L-Trp, D-Trp, L-Tyr, D-Tyr, L-Phe, D-Phe were investigated and only L-Trp could well chelated copper ion. Additionally, the mechanism of quench and recovery also were discussed and the method was successfully applied to detect the adenine in DNA with satisfactory results. Copyright © 2015 Elsevier B.V. All rights reserved.
Live Cell Visualization of Multiple Protein-Protein Interactions with BiFC Rainbow.
Wang, Sheng; Ding, Miao; Xue, Boxin; Hou, Yingping; Sun, Yujie
2018-05-18
As one of the most powerful tools to visualize PPIs in living cells, bimolecular fluorescence complementation (BiFC) has gained great advancement during recent years, including deep tissue imaging with far-red or near-infrared fluorescent proteins or super-resolution imaging with photochromic fluorescent proteins. However, little progress has been made toward simultaneous detection and visualization of multiple PPIs in the same cell, mainly due to the spectral crosstalk. In this report, we developed novel BiFC assays based on large-Stokes-shift fluorescent proteins (LSS-FPs) to detect and visualize multiple PPIs in living cells. With the large excitation/emission spectral separation, LSS-FPs can be imaged together with normal Stokes shift fluorescent proteins to realize multicolor BiFC imaging using a simple illumination scheme. We also further demonstrated BiFC rainbow combining newly developed BiFC assays with previously established mCerulean/mVenus-based BiFC assays to achieve detection and visualization of four PPI pairs in the same cell. Additionally, we prove that with the complete spectral separation of mT-Sapphire and CyOFP1, LSS-FP-based BiFC assays can be readily combined with intensity-based FRET measurement to detect ternary protein complex formation with minimal spectral crosstalk. Thus, our newly developed LSS-FP-based BiFC assays not only expand the fluorescent protein toolbox available for BiFC but also facilitate the detection and visualization of multiple protein complex interactions in living cells.
Fan, Yao; Liu, Li; Sun, Donglei; Lan, Hanyue; Fu, Haiyan; Yang, Tianming; She, Yuanbin; Ni, Chuang
2016-04-15
As a popular detection model, the fluorescence "turn-off" sensor based on quantum dots (QDs) has already been successfully employed in the detections of many materials, especially in the researches on the interactions between pesticides. However, the previous studies are mainly focused on simple single track or the comparison based on similar concentration of drugs. In this work, a new detection method based on the fluorescence "turn-off" model with water-soluble ZnCdSe and CdSe QDs simultaneously as the fluorescent probes is established to detect various pesticides. The fluorescence of the two QDs can be quenched by different pesticides with varying degrees, which leads to the differences in positions and intensities of two peaks. By combining with chemometrics methods, all the pesticides can be qualitative and quantitative respectively even in real samples with the limit of detection was 2 × 10(-8) mol L(-1) and a recognition rate of 100%. This work is, to the best of our knowledge, the first report on the detection of pesticides based on the fluorescence quenching phenomenon of double quantum dots combined with chemometrics methods. What's more, the excellent selectivity of the system has been verified in different mediums such as mixed ion disruption, waste water, tea and water extraction liquid drugs. Copyright © 2016 Elsevier B.V. All rights reserved.
Turn on ESPT: novel salicylaldehyde based sensor for biological important fluoride sensing.
Liu, Kai; Zhao, Xiaojun; Liu, Qingxiang; Huo, Jianzhong; Fu, Huifang; Wang, Ying
2014-09-05
A novel and simple salicylaldehyde based anion fluorescent sensor 1 has been designed, which can selectively sense fluoride by 'turn on' excited-state intermolecular proton transfer (ESPT). The binding constant and the stoichiometry were obtained by non-linear least-square analysis of the titration curves. Copyright © 2014 Elsevier B.V. All rights reserved.
Liu, Junyan; Liu, Yang; Gao, Mingxia; Zhang, Xiangmin
2012-08-01
A facile proteomic quantification method, fluorescent labeling absolute quantification (FLAQ), was developed. Instead of using MS for quantification, the FLAQ method is a chromatography-based quantification in combination with MS for identification. Multidimensional liquid chromatography (MDLC) with laser-induced fluorescence (LIF) detection with high accuracy and tandem MS system were employed for FLAQ. Several requirements should be met for fluorescent labeling in MS identification: Labeling completeness, minimum side-reactions, simple MS spectra, and no extra tandem MS fragmentations for structure elucidations. A fluorescence dye, 5-iodoacetamidofluorescein, was finally chosen to label proteins on all cysteine residues. The fluorescent dye was compatible with the process of the trypsin digestion and MALDI MS identification. Quantitative labeling was achieved with optimization of reacting conditions. A synthesized peptide and model proteins, BSA (35 cysteines), OVA (five cysteines), were used for verifying the completeness of labeling. Proteins were separated through MDLC and quantified based on fluorescent intensities, followed by MS identification. High accuracy (RSD% < 1.58) and wide linearity of quantification (1-10(5) ) were achieved by LIF detection. The limit of quantitation for the model protein was as low as 0.34 amol. Parts of proteins in human liver proteome were quantified and demonstrated using FLAQ. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fang, Mingli; Diao, Wenzhen; Dong, Boqi; Wei, Hongfei; Liu, Jialin; Hua, Li; Zhang, Miaomin; Guo, Sheng; Xiao, Yue; Yu, Yongli; Wang, Liying; Wan, Min
2015-01-01
Monitoring the assembly and disassembly of virus-like particles (VLPs) is important in developing effective VLP-based vaccines. We tried to establish a simple and rapid method to evaluate the status of VLP assembly using fluorescence spectroscopic analysis (FSA) while developing a VLP-based vaccine against porcine circovirus type 2b (PCV2b). We synthesized the gene coding for PCV2b capsid protein (CP). The CP was expressed in Escherichia coli in a soluble form, dialyzed into three different buffers, and assembled into VLPs. The immunogenicity of the VLPs was evaluated by an enzyme-linked immunosorbent assay using the sera of mice immunized with inactivated PCV2b. The VLP assembly was detected using transmission electron microscopy and FSA. The assembled VLPs showed a distinct FSA curve with a peak at 320 nm. We found that the assembly status was related to the immunogenicity, fluorescence intensity, and morphology of the VLP. The FSA assay was able to monitor the various denatured statuses of PCV2b VLPs treated with β-mercaptoethanol or β-mercaptoethanol plus urea. We have demonstrated that FSA can be used to detect the assembly of PCV2b VLPs produced in E. coli. This provides a simple solution for monitoring VLP assembly during the production of VLP-based vaccines. © 2016 S. Karger AG, Basel.
Alasaad, Samer; Soriguer, Ramón C; Abu-Madi, Marawan; El Behairy, Ahmed; Baños, Pablo Díez; Píriz, Ana; Fickel, Joerns; Zhu, Xing-Quan
2011-06-01
The present study aimed to establish a fluorescence-based polymerase chain reaction-linked single-strand conformation polymorphism (F-PCR-SSCP) assay for the identification of Fasciola spp. Based on the sequences of the second internal transcribed spacer (ITS-2) of the nuclear ribosomal DNA, we designed a set of genus-specific primers for the amplification of Fasciola ITS-2, with an estimated size of 140 bp. These primers were labelled by fluorescence dyes, and the PCR products were analyzed by capillary electrophoresis under non-denaturing conditions (F-PCR-SSCP). Capillary electrophoresis analysis of the fluorescence-labelled DNA fragments displayed three different peak profiles that allowed the accurate identification of Fasciola species: one single peak specific for either Fasciola hepatica or Fasciola gigantica and a doublet peak corresponding to the "intermediate" Fasciola. Validation of our novel method was performed using Fasciola specimens from different host animals from China, Spain, Nigeria, and Egypt. This F-PCR-SSCP assay provides a rapid, simple, and robust tool for the identification and differentiation between Fasciola spp.
Liu, Si-Yao; Wang, Huan; He, Tian; Qi, Liang; Zhang, Zhi-Qi
2016-02-01
A fluorescence method was established for a α-glucosidase activity assay and inhibitor screening based on β-cyclodextrin-coated quantum dots. p-Nitrophenol, the hydrolysis product of the α-glucosidase reaction, could quench the fluorescence of β-cyclodextrin-coated quantum dots via an electron transfer process, leading to fluorescence turn-off, whereas the fluorescence of the system turned on in the presence of α-glucosidase inhibitors. Taking advantage of the excellent properties of quantum dots, this method provided a very simple, rapid and sensitive screening method for α-glucosidase inhibitors. Two α-glucosidase inhibitors, 2,4,6-tribromophenol and acarbose, were used to evaluate the feasibility of this screening model, and IC50 values of 24 μM and 0.55 mM were obtained respectively, which were lower than those previously reported. The method may have potential application in screening α-glucosidase inhibitors. Copyright © 2015 John Wiley & Sons, Ltd.
Fael, Hanan; Sakur, Amir Al-Haj
2015-11-01
A novel, simple and specific spectrofluorimetric method was developed and validated for the determination of perindopril erbumine (PDE). The method is based on the fluorescence quenching of Rhodamine B upon adding perindopril erbumine. The quenched fluorescence was monitored at 578 nm after excitation at 500 nm. The optimization of the reaction conditions such as the solvent, reagent concentration, and reaction time were investigated. Under the optimum conditions, the fluorescence quenching was linear over a concentration range of 1.0-6.0 μg/mL. The proposed method was fully validated and successfully applied to the analysis of perindopril erbumine in pure form and tablets. Statistical comparison of the results obtained by the developed and reference methods revealed no significant differences between the methods compared in terms of accuracy and precision. The method was shown to be highly specific in the presence of indapamide, a diuretic that is commonly combined with perindopril erbumine. The mechanism of rhodamine B quenching was also discussed.
Wang, Hao; Wang, Jialin; Yang, Shaoxiang; Tian, Hongyu; Sun, Baoguo; Liu, Yongguo
2018-01-01
A new reaction-based fluorescent probe 6-cyanonaphthalen-2-yl-2,4- dinitrobenzenesulfonate (probe 1) was designed and synthesized for detection of hydrogen sulfide (H 2 S). The addition of H 2 S to a solution of probe 1 resulted in a marked fluorescence increased accompanied by a visual color change from colorless to yellow. Importantly, this distinct color response indicates that probe 1 could be used as a visual tool for detection of H 2 S. H 2 S can be detected quantitatively in the concentration range 0 to 25 μM and the detection limit was 30 nM. Moreover, probe 1 was successfully used as a sensor to determine H 2 S levels in red wine and beer. Fluorescent probe 1 could be employed as a visible sensor for H 2 S. Probe 1 could be used to detect H 2 S quantitatively in food simple. © 2017 Institute of Food Technologists®.
A CTRW-based model of time-resolved fluorescence lifetime imaging in a turbid medium
NASA Astrophysics Data System (ADS)
Chernomordik, Victor; Gandjbakhche, Amir H.; Hassan, Moinuddin; Pajevic, Sinisa; Weiss, George H.
2010-12-01
We develop an analytic model of time-resolved fluorescent imaging of photons migrating through a semi-infinite turbid medium bounded by an infinite plane in the presence of a single stationary point fluorophore embedded in the medium. In contrast to earlier models of fluorescent imaging in which photon motion is assumed to be some form of continuous diffusion process, the present analysis is based on a continuous-time random walk (CTRW) on a simple cubic lattice, the objective being to estimate the position and lifetime of the fluorophore. This can provide information related to local variations in pH and temperature with potential medical significance. Aspects of the theory were tested using time-resolved measurements of the fluorescence from small inclusions inside tissue-like phantoms. The experimental results were found to be in good agreement with theoretical predictions provided that the fluorophore was not located too close to the planar boundary, a common problem in many diffusive systems.
Han, Daehoon; Hong, Jinkee; Kim, Hyun Cheol; Sung, Jong Hwan; Lee, Jong Bum
2013-11-01
Many highly sensitive protein detection techniques have been developed and have played an important role in the analysis of proteins. Herein, we report a novel technique that can detect proteins sensitively and effectively using aptamer-based DNA nanostructures. Thrombin was used as a target protein and aptamer was used to capture fluorescent dye-labeled DNA nanobarcodes or thrombin on a microsphere. The captured DNA nanobarcodes were replaced by a thrombin and aptamer interaction. The detection ability of this approach was confirmed by flow cytometry with different concentrations of thrombin. Our detection method has great potential for rapid and simple protein detection with a variety of aptamers.
Quinoline containing acetyl hydrazone: An easily accessible switch-on optical chemosensor for Zn2 +
NASA Astrophysics Data System (ADS)
Wu, Wei-Na; Mao, Pan-Dong; Wang, Yuan; Zhao, Xiao-Lei; Xu, Zhou-Qing; Xu, Zhi-Hong; Xue, Yuan
2018-01-01
A simple chemosensor, namely, N-((quinolin-8-yl)methylene)acetohydrazide (1) was synthesized and used as an off-on fluorescence sensor, which exhibits high selectivity toward Zn2 + in aqueous media. The probe has large Stokes shift of > 200 nm, and its detection limit for Zn2 + is 89.3 nM. The binding process was confirmed through UV-vis absorption analysis, fluorescence measurements, mass spectroscopy study, 1H NMR spectra and density functional theory calculation. The crystal structures of Zn2 +, Ni2 +, and Cu2 + complexes based on 1 were determined through X-ray crystallographic analysis. The fluorescent probe was then applied to monitor intracellular Zn2 + in HeLa cells.
Lin, Li-Rong; Luo, He-Dong; Li, Xiu-Ying; Li, Na; Zhou, Na; Jia, Yu-Zhu; Liu, Yi-Hong; Li, Yao-Qun
2014-01-01
Based on the high solubility efficiency and strong fluorescence response of benzo(a)pyrene (BaP) in dimethyl sulfoxide in combination with the high-performance derivative constant-energy synchronous fluorescence spectroscopic (DCESFS) technique, a simple, sensitive and economic method was developed for the determination of BaP in liquid milk. This method comprises ultrasound-assisted solvent extraction, solvent replacement and DCESFS detection. No saponification or other tedious clean-up procedures were needed. The recoveries of BaP in different milk samples were greater than 82%. Detection limits in full- and low-fat milk were 0.03 and 0.04 μg kg(-1), respectively.
NASA Astrophysics Data System (ADS)
Cao, Ming; Liu, Meigui; Cao, Chun; Xia, Yunsheng; Bao, Linjun; Jin, Yingqiong; Yang, Song; Zhu, Changqing
2010-03-01
A novel method for the determination of berberine has been developed based on quenching of the fluorescence of thioglycolic acid-capped CdTe quantum dots (TGA-CdTe QDs) by berberine in aqueous solutions. Under optimum conditions, the relative fluorescence intensity was linearly proportional to the concentration of berberine between 2.5 × 10 -8 and 8.0 × 10 -6 mol L -1 with a detection limit of 6.0 × 10 -9 mol L -1. The method has been applied to the determination of berberine in real samples, and satisfactory results were obtained. The mechanism of the proposed reaction was also discussed.
Björn, Lars Olof; Li, Shaoshan
2013-10-01
Solar energy absorbed by plants results in either reflection or absorption. The latter results in photosynthesis, fluorescence, or heat. Measurements of fluorescence changes have been used for monitoring processes associated with photosynthesis. A simple method to follow changes in leaf fluorescence and leaf reflectance associated with nonphotochemical quenching and light acclimation of leaves is described. The main equipment needed consists of a green-light emitting laser pointer, a digital camera, and a personal computer equipped with the camera acquisition software and the programs ImageJ and Excel. Otherwise, only commonly available cheap materials are required.
Simple approach to three-color two-photon microscopy by a fiber-optic wavelength convertor.
Li, Kuen-Che; Huang, Lynn L H; Liang, Jhih-Hao; Chan, Ming-Che
2016-11-01
A simple approach to multi-color two-photon microscopy of the red, green, and blue fluorescent indicators was reported based on an ultra-compact 1.03-μm femtosecond laser and a nonlinear fiber. Inside the nonlinear fiber, the 1.03-μm laser pulses were simultaneously blue-shifted to 0.6~0.8 μm and red-shifted to 1.2~1.4 μm region by the Cherenkov radiation and fiber Raman gain effects. The wavelength-shifted 0.6~0.8 μm and 1.2~1.4 μm radiations were co-propagated with the residual non-converted 1.03-μm pulses inside the same nonlinear fiber to form a fiber-output three-color femtosecond source. The application of the multi-wavelength sources on multi-color two-photon fluorescence microscopy were also demonstrated. Overall, due to simple system configuration, convenient wavelength conversion, easy wavelength tunability within the entire 0.7~1.35 μm bio-penetration window and less requirement for high power and bulky light sources, the simple approach to multi-color two-photon microscopy could be widely applicable as an easily implemented and excellent research tool for future biomedical and possibly even clinical applications.
Xiao, Kunyi; Liu, Juan; Chen, Hui; Zhang, Song; Kong, Jilie
2017-05-15
A label-free and high-efficient graphene oxide (GO)-based aptasensor was developed for the detection of low quantity cancer cells based on cell-triggered cyclic enzymatic signal amplification (CTCESA). In the absence of target cells, hairpin aptamer probes (HAPs) and dye-labeled linker DNAs stably coexisted in solution, and the fluorescence was quenched by the GO-based FÖrster resonance energy transfer (FRET) process. In the presence of target cells, the specific binding of HAPs with the target cells triggered a conformational alternation, which resulted in linker DNA complementary pairing and cleavage by nicking endonuclease-strand scission cycles. Consequently, more cleaved fragments of linker DNAs with more the terminal labeled dyes could show the enhanced fluorescence because these cleaved DNA fragments hardly combine with GOs and prevent the FRET process. Fluorescence analysis demonstrated that this GO-based aptasensor exhibited selective and sensitive response to the presence of target CCRF-CEM cells in the concentration range from 50 to 10 5 cells. The detection limit of this method was 25 cells, which was approximately 20 times lower than the detection limit of normal fluorescence aptasensors without amplification. With high sensitivity and specificity, it provided a simple and cost-effective approach for early cancer diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
DETECTION OF DNA DAMAGE USING MELTING ANALYSIS TECHNIQUES
A rapid and simple fluorescence screening assay for UV radiation-, chemical-, and enzyme-induced DNA damage is reported. This assay is based on a melting/annealing analysis technique and has been used with both calf thymus DNA and plasmid DNA (puc 19 plasmid from E. coli). DN...
Independently segregating simple sequence repeats (SSR) alleles in polyploid sugarcane
USDA-ARS?s Scientific Manuscript database
The complex nuclear genomic and flower structures of sugarcane cultivars (Saccharum hybrids spp., 2n = 10x = 100 – 130) render sugarcane a difficult subject for genetics research. Using a capillary electrophoresis- and fluorescence-labeling-based SSR genotyping platform, the segregation of a multi-a...
Fluorescence detection of trace PCB101 based on PITC immobilized on porous AAO membrane.
Wang, Meiling; Meng, Guowen; Huang, Qing; Li, Mingtao; Li, Zhongbo; Tang, Chaolong
2011-01-21
A sensitive and selective fluorescent membrane for rapid detection of trace 2,2',4,5,5'-pentachlorinated biphenyl (PCB101) has been achieved by immobilizing the fluorophore phenyl isothiocyanate (PITC) onto porous anodic aluminium oxide (AAO) membrane (denoted as PITC@AAO). The fluorescence of the PITC@AAO membrane is obviously enhanced after titrating the analyte PCB101 into the membrane, being ascribed to the halogen-bonding interaction between the fluorophore PITC and the analyte PCB101. The fluorescence intensity increases with the PCB101 concentration in the low range below 1 ppm, and there exists an approximate linear relationship between the relative fluorescence intensity and the PCB101 concentration in the low range of 1-6 ppb. Moreover, the PITC@AAO membrane shows good selectivity; for example, it is insensitive to common structural analogs (polychlorinated aromatics). The mechanisms of the fluorescence enhancement and the better sensitivity and selectivity of the PITC@AAO membrane to PCB101 than that of PITC/n-hexane solution are also discussed. This work demonstrates that trace (in ppb range) PCBs can be detected by simple fluorescence measurement.
Glutathione-capped CdTe nanocrystals as probe for the determination of fenbendazole.
Li, Qin; Tan, Xuanping; Li, Jin; Pan, Li; Liu, Xiaorong
2015-04-15
Water-soluble glutathione (GSH)-capped CdTe quantum dots (QDs) were synthesized. In pH 7.1 PBS buffer solution, the interaction between GSH-capped CdTe QDs and fenbendazole (FBZ) was investigated by spectroscopic methods, including fluorescence spectroscopy, ultraviolet-visible absorption spectroscopy, and resonance Rayleigh scattering (RRS) spectroscopy. In GSH-capped CdTe QDs solution, the addition of FBZ results in the fluorescence quenching and RRS enhancement of GSH-capped CdTe QDs. And the quenching intensity (enhanced RRS intensity) was proportional to the concentration of FBZ in a certain range. Investigation of the interaction mechanism, proved that the fluorescence quenching and RRS enhancement of GSH-capped CdTe QDs by FBZ is the result of electrostatic attraction. Based on the quenching of fluorescence (enhancement of RRS) of GSH-capped CdTe QDs by FBZ, a novel, simple, rapid and specific method for FBZ determination was proposed. The detection limit for FBZ was 42 ng mL(-1) (3.4 ng mL(-1)) and the quantitative determination range was 0-2.8 μg mL(-1) with a correlation of 0.9985 (0.9979). The method has been applied to detect FBZ in real simples and with satisfactory results. Copyright © 2015 Elsevier B.V. All rights reserved.
Development of a Terbium-Sensitized Fluorescence Method for Analysis of Silibinin.
Ershadi, Saba; Jouyban, Abolghasem; Molavi, Ommoleila; Shayanfar, Ali
2017-05-01
Silibinin is a natural flavonoid with potent anticancer properties, as shown in both in vitro and in vivo experiments. Various methods have been used for silibinin analysis. Terbium-sensitized fluorescence methods have been widely used for the determination of drugs in pharmaceutical preparations and biological samples in recent years. The present work is aimed at providing a simple analytical method for the quantitative determination of silibinin in aqueous solutions based on the formation of a fluorescent complex with terbium ion. Terbium concentration, pH, and volume of buffer, the important effective parameters for the determination of silibinin by the proposed method, were optimized using response surface methodology. The fluorescence intensity of silibinin was measured at 545 nm using λex = 334 nm. The developed method was applied for the determination of silibinin in plasma samples after protein precipitation with acetone. Under optimum conditions, the method provided a linear range between 0.10 and 0.50 mg/L, with a coefficient of determination (R2) of 0.997. The LOD and LOQ were 0.034 and 0.112 mg/L, respectively. These results indicate that the developed method is a simple, low-cost, and suitable analytical method for the quantification of silibinin in aqueous solution and plasma samples.
Chang, Jiahua; Bahethan, Bota; Muhammad, Turghun; Yakup, Burabiye; Abbas, Mamatimin
2017-01-01
In this paper, we report the preparation of molecularly imprinted polymer coatings on quartz chips for selective solid-phase microextraction and fluorescence sensing of the auxin, indole-3-butyric acid. The multiple copolymerization method was used to prepare polymer coatings on silylated quartz chips. The polymer preparation conditions (e.g., the solvent, monomer, and cross-linker) were investigated systemically to enhance the binding performance of the imprinted coatings. Direct solid-phase fluorescence measurements on the chips facilitated monitoring changes in coating performance. The average binding capacity of an imprinted polymer coated chip was approximately 152.9 µg, which was higher than that of a non-imprinted polymer coated chip (60.8 µg); the imprinted coatings showed the highest binding to IBA among the structural analogues, indicating that the coatings possess high selectivity toward the template molecule. The developed method was used for the determination of the auxin in mung bean extraction, and the recovery was found to be in the range of 91.5% to 97.5%, with an RSD (n = 3) of less than 7.4%. Thus, the present study provides a simple method for fabricating a fluorescent sensor chip for selective analysis. PMID:28837081
Jiang, Hu; Li, Xiangmin; Xiong, Ying; Pei, Ke; Nie, Lijuan; Xiong, Yonghua
2017-02-28
A silver nanoparticle (AgNP)-based fluorescence-quenching lateral flow immunoassay with competitive format (cLFIA) was developed for sensitive detection of ochratoxin A (OTA) in grape juice and wine samples in the present study. The Ru(phen) 3 2 + -doped silica nanoparticles (RuNPs) were sprayed on the test and control line zones as background fluorescence signals. The AgNPs were designed as the fluorescence quenchers of RuNPs because they can block the exciting light transferring to the RuNP molecules. The proposed method exhibited high sensitivity for OTA detection, with a detection limit of 0.06 µg/L under optimized conditions. The method also exhibited a good linear range for OTA quantitative analysis from 0.08 µg/L to 5.0 µg/L. The reliability of the fluorescence-quenching cLFIA method was evaluated through analysis of the OTA-spiked red grape wine and juice samples. The average recoveries ranged from 88.0% to 110.0% in red grape wine and from 92.0% to 110.0% in grape juice. Meanwhile, less than a 10% coefficient variation indicated an acceptable precision of the cLFIA method. In summary, the new AgNP-based fluorescence-quenching cLFIA is a simple, rapid, sensitive, and accurate method for quantitative detection of OTA in grape juice and wine or other foodstuffs.
Jiang, Hu; Li, Xiangmin; Xiong, Ying; Pei, Ke; Nie, Lijuan; Xiong, Yonghua
2017-01-01
A silver nanoparticle (AgNP)-based fluorescence-quenching lateral flow immunoassay with competitive format (cLFIA) was developed for sensitive detection of ochratoxin A (OTA) in grape juice and wine samples in the present study. The Ru(phen)32+-doped silica nanoparticles (RuNPs) were sprayed on the test and control line zones as background fluorescence signals. The AgNPs were designed as the fluorescence quenchers of RuNPs because they can block the exciting light transferring to the RuNP molecules. The proposed method exhibited high sensitivity for OTA detection, with a detection limit of 0.06 µg/L under optimized conditions. The method also exhibited a good linear range for OTA quantitative analysis from 0.08 µg/L to 5.0 µg/L. The reliability of the fluorescence-quenching cLFIA method was evaluated through analysis of the OTA-spiked red grape wine and juice samples. The average recoveries ranged from 88.0% to 110.0% in red grape wine and from 92.0% to 110.0% in grape juice. Meanwhile, less than a 10% coefficient variation indicated an acceptable precision of the cLFIA method. In summary, the new AgNP-based fluorescence-quenching cLFIA is a simple, rapid, sensitive, and accurate method for quantitative detection of OTA in grape juice and wine or other foodstuffs. PMID:28264472
Arraud, Nicolas; Gounou, Céline; Turpin, Delphine; Brisson, Alain R
2016-02-01
Plasma contains cell-derived extracellular vesicles (EVs) which participate in various physiopathological processes and have potential biomedical applications. Despite intense research activity, knowledge on EVs is limited mainly due to the difficulty of isolating and characterizing sub-micrometer particles like EVs. We have recently reported that a simple flow cytometry (FCM) approach based on triggering the detection on a fluorescence signal enabled the detection of 50× more Annexin-A5 binding EVs (Anx5+ EVs) in plasma than the conventional FCM approach based on light scattering triggering. Here, we present the application of the fluorescence triggering approach to the enumeration and phenotyping of EVs from platelet free plasma (PFP), focusing on CD41+ and CD235a+ EVs, as well as their sub-populations which bind or do not bind Anx5. Higher EV concentrations were detected by fluorescence triggering as compared to light scattering triggering, namely 40× for Anx5+ EVs, 75× for CD41+ EVs, and 15× for CD235a+ EVs. We found that about 30% of Anx5+ EVs were of platelet origin while only 3% of them were of erythrocyte origin. In addition, a majority of EVs from platelet and erythrocyte origin do not expose PS, in contrast to the classical theory of EV formation. Furthermore, the same PFP samples were analyzed fresh and after freeze-thawing, showing that freeze-thawing processes induce an increase, of about 35%, in the amount of Anx5+ EVs, while the other EV phenotypes remain unchanged. The method of EV detection and phenotyping by fluorescence triggering is simple, sensitive and reliable. We foresee that its application to EV studies will improve our understanding on the formation mechanisms and functions of EVs in health and disease and help the development of EV-based biomarkers. © 2015 International Society for Advancement of Cytometry.
NASA Astrophysics Data System (ADS)
Padmanabhan, Saraswathi; Shinoj, Vengalathunadakal K.; Murukeshan, Vadakke M.; Padmanabhan, Parasuraman
2010-01-01
A simple optical method using hollow-core photonic crystal fiber for protein detection has been described. In this study, estrogen receptor (ER) from a MCF-7 breast carcinoma cell lysates immobilized inside a hollow-core photonic crystal fiber was detected using anti-ER primary antibody with either Alexa™ Fluor 488 (green fluorescent dye) or 555 (red Fluorescent dye) labeled Goat anti-rabbit IgG as the secondary antibody. The fluorescence fingerprints of the ERα protein were observed under fluorescence microscope, and its optical characteristics were analyzed. The ERα protein detection by this proposed method is based on immuno binding from sample volume as low as 50 nL. This method is expected to offer great potential as a biosensor for medical diagnostics and therapeutics applications.
Low-Cost Charged-Coupled Device (CCD) Based Detectors for Shiga Toxins Activity Analysis.
Rasooly, Reuven; Prickril, Ben; Bruck, Hugh A; Rasooly, Avraham
2017-01-01
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of food-borne pathogens and their toxins. We describe a simple, low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemiluminescence, densitometry, and colorimetric assays. The portable battery-operated CCD-based detection system consists of four modules: (1) a webcam to measure and record light emission, (2) a sample plate to perform assays, (3) a light emitting diode (LED) for illumination, and (4) a portable computer to acquire and analyze images. To demonstrate the technology, we used a cell based assay for fluorescence detection of the activity of the food borne Shiga toxin type 2 (Stx2), differentiating between biologically active toxin and inactive toxin which is not a risk. The assay is based on Shiga toxin inhibition of cell protein synthesis measured through inhibition of the green fluorescent protein (GFP). In this assay, GFP emits light at 509 nm when excited with a blue LED equipped with a filter at 486 nm. The emitted light is then detected with a green filter at 535 nm. Toxin activity is measured through a reduction in the 509 nm emission. In this system the level of detection (LOD) for Stx2 was 0.1 pg/ml, similar to the LOD of commercial fluorometers. These results demonstrate the utility and potential of low cost detectors for toxin activity. This approach could be readily adapted to the detection of other food-borne toxins.
One-pot synthesis of active copper-containing carbon dots with laccase-like activities
NASA Astrophysics Data System (ADS)
Ren, Xiangling; Liu, Jing; Ren, Jun; Tang, Fangqiong; Meng, Xianwei
2015-11-01
Herein, an effective strategy for designing a new type of nanozyme, blue fluorescent laccase mimics, is reported. Active copper-containing carbon dots (Cu-CDs) were synthesized through a simple, nontoxic and one-pot hydrothermal method, which showed favorable photoluminescence properties and good photostability under high-salt conditions or in a broad pH range (3.0-13.5). The Cu-CDs possessed intrinsic laccase-like activities and could catalyze the oxidation of the laccase substrate p-phenylenediamine (PPD) to produce a typical color change from colorless to brown. Poly(methacrylic acid sodium salt) (PMAA) not only was used as the carbon source and reducing agent, but also provided carboxyl groups to assist flocculation between Cu-CDs and polyacrylamide, which facilitated the removal of PPD. Importantly, the intrinsic fluorescence of the as-prepared Cu-CDs could indicate the presence of hydroquinone, one of the substrates of laccases, based on laccase mimics and fluorescence quenching.Herein, an effective strategy for designing a new type of nanozyme, blue fluorescent laccase mimics, is reported. Active copper-containing carbon dots (Cu-CDs) were synthesized through a simple, nontoxic and one-pot hydrothermal method, which showed favorable photoluminescence properties and good photostability under high-salt conditions or in a broad pH range (3.0-13.5). The Cu-CDs possessed intrinsic laccase-like activities and could catalyze the oxidation of the laccase substrate p-phenylenediamine (PPD) to produce a typical color change from colorless to brown. Poly(methacrylic acid sodium salt) (PMAA) not only was used as the carbon source and reducing agent, but also provided carboxyl groups to assist flocculation between Cu-CDs and polyacrylamide, which facilitated the removal of PPD. Importantly, the intrinsic fluorescence of the as-prepared Cu-CDs could indicate the presence of hydroquinone, one of the substrates of laccases, based on laccase mimics and fluorescence quenching. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr04685h
Gerstner, Arpad; DeFord, James H; Papaconstantinou, John
2003-07-25
Ames dwarfism is caused by a homozygous single nucleotide mutation in the pituitary specific prop-1 gene, resulting in combined pituitary hormone deficiency, reduced growth and extended lifespan. Thus, these mice serve as an important model system for endocrinological, aging and longevity studies. Because the phenotype of wild type and heterozygous mice is undistinguishable, it is imperative for successful breeding to accurately genotype these animals. Here we report a novel, yet simple, approach for prop-1 genotyping using PCR-based allele-specific amplification (PCR-ASA). We also compare this method to other potential genotyping techniques, i.e. PCR-based restriction fragment length polymorphism analysis (PCR-RFLP) and fluorescence automated DNA sequencing. We demonstrate that the single-step PCR-ASA has several advantages over the classical PCR-RFLP because the procedure is simple, less expensive and rapid. To further increase the specificity and sensitivity of the PCR-ASA, we introduced a single-base mismatch at the 3' penultimate position of the mutant primer. Our results also reveal that the fluorescence automated DNA sequencing has limitations for detecting a single nucleotide polymorphism in the prop-1 gene, particularly in heterozygotes.
Rachofsky, E L; Osman, R; Ross, J B
2001-01-30
2-Aminopurine (2AP) is an analogue of adenine that has been utilized widely as a fluorescence probe of protein-induced local conformational changes in DNA. Within a DNA strand, this fluorophore demonstrates characteristic decreases in quantum yield and emission decay lifetime that vary sensitively with base sequence, temperature, and helix conformation but that are accompanied by only small changes in emission wavelength. However, the molecular interactions that give rise to these spectroscopic changes have not been established. To develop a molecular model for interpreting the fluorescence measurements, we have investigated the effects of environmental polarity, hydrogen bonding, and the purine and pyrimidine bases of DNA on the emission energy, quantum yield, and intensity decay kinetics of 2AP in simple model systems. The effects of environmental polarity were examined in a series of solvents of varying dielectric constant, and hydrogen bonding was investigated in binary mixtures of water with 1,4-dioxane or N,N-dimethylformamide (DMF). The effects of the purine and pyrimidine bases were studied by titrating 2AP deoxyriboside (d2AP) with the nucleosides adenosine (rA), cytidine (rC), guanosine (rG), and deoxythymidine (dT), and the nucleoside triphosphates ATP and GTP in neutral aqueous solution. The nucleosides and NTPs each quench the fluorescence of d2AP by a combination of static (affecting only the quantum yield) and dynamic (affecting both the quantum yield and the lifetime, proportionately) mechanisms. The peak wavelength and shape of the emission spectrum are not altered by either of these effects. The static quenching is saturable and has half-maximal effect at approximately 20 mM nucleoside or NTP, consistent with an aromatic stacking interaction. The rate constant for dynamic quenching is near the diffusion limit for collisional interaction (k(q) approximately 2 x 10(9) M(-1) s(-1)). Neither of these effects varies significantly between the various nucleosides and NTPs studied. In contrast, hydrogen bonding with water was observed to have a negligible effect on the emission wavelength, fluorescence quantum yield, or lifetime of 2AP in either dioxane or DMF. In nonpolar solvents, the fluorescence lifetime and quantum yield decrease dramatically, accompanied by significant shifts in the emission spectrum to shorter wavelengths. However, these effects of polarity do not coincide with the observed emission wavelength-independent quenching of 2AP fluorescence in DNA. Therefore, we conclude that the fluorescence quenching of 2AP in DNA arises from base stacking and collisions with neighboring bases only but is insensitive to base-pairing or other hydrogen bonding interactions. These results implicate both structural and dynamic properties of DNA in quenching of 2AP and constitute a simple model within which the fluorescence changes induced by protein-DNA binding or other perturbations may be interpreted.
Light emission from organic single crystals operated by electrolyte doping
NASA Astrophysics Data System (ADS)
Matsuki, Keiichiro; Sakanoue, Tomo; Yomogida, Yohei; Hotta, Shu; Takenobu, Taishi
2018-03-01
Light-emitting devices based on electrolytes, such as light-emitting electrochemical cells (LECs) and electric double-layer transistors (EDLTs), are solution-processable devices with a very simple structure. Therefore, it is necessary to apply this device structure into highly fluorescent organic materials for future printed applications. However, owing to compatibility problems between electrolytes and organic crystals, electrolyte-based single-crystal light-emitting devices have not yet been demonstrated. Here, we report on light-emitting devices based on organic single crystals and electrolytes. As the fluorescent materials, α,ω-bis(biphenylyl)terthiophene (BP3T) and 5,6,11,12-tetraphenylnaphthacene (rubrene) single crystals were selected. Using ionic liquids as electrolytes, we observed clear light emission from BP3T LECs and rubrene EDLTs.
Fluorescence turn-on sensing of trace cadmium ions based on EDTA-etched CdTe@CdS quantum dot.
Wang, Si-Nan; Zhu, Jian; Li, Xin; Li, Jian-Jun; Zhao, Jun-Wu
2018-05-01
Cadmium-caused environmental pollution and diseases have always been worldwide problems. Thus it is extremely urgent to establish a cheap, rapid, simple and selective detection method for trace cadmium in drinking water. In this study, a fluorescence "turn-on" method based on ethylene diamine tetraacetic acid (EDTA)-etched CdTe@CdS quantum dots (QDs) was designed to detect Cd 2+ . High resolution transmission electron microscopy (HRTEM) and X-ray photoelectron spectroscopy (XPS) were utilized for chemical and structural characterization of the as-prepared QDs. Based on chemical etching of EDTA on the surface of CdTe@CdS QDs, specific Cd 2+ recognition sites were produced, and then results in fluorescence quenching. The introduction of Cd 2+ could identify these sites and restore the fluorescence of the EDTA-QDs system. Under the optimum conditions, the nanoprobe shows a linear response range from 0.05 to 9 μM with a very low detection limit of 0.032 μM. In addition, the reported fluorescence probe in this work displays a good selectivity for trace Cd 2+ over other metal ions and an admirable practicability in real water samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Aptamer-Based Dual-Functional Probe for Rapid and Specific Counting and Imaging of MCF-7 Cells.
Yang, Bin; Chen, Beibei; He, Man; Yin, Xiao; Xu, Chi; Hu, Bin
2018-02-06
Development of multimodal detection technologies for accurate diagnosis of cancer at early stages is in great demand. In this work, we report a novel approach using an aptamer-based dual-functional probe for rapid, sensitive, and specific counting and visualization of MCF-7 cells by inductively coupled plasma-mass spectrometry (ICP-MS) and fluorescence imaging. The probe consists of a recognition unit of aptamer to catch cancer cells specifically, a fluorescent dye (FAM) moiety for fluorescence resonance energy transfer (FRET)-based "off-on" fluorescence imaging as well as gold nanoparticles (Au NPs) tag for both ICP-MS quantification and fluorescence quenching. Due to the signal amplification effect and low spectral interference of Au NPs in ICP-MS, an excellent linearity and sensitivity were achieved. Accordingly, a limit of detection of 81 MCF-7 cells and a relative standard deviation of 5.6% (800 cells, n = 7) were obtained. The dynamic linear range was 2 × 10 2 to 1.2 × 10 4 cells, and the recoveries in human whole blood were in the range of 98-110%. Overall, the established method provides quantitative and visualized information on MCF-7 cells with a simple and rapid process and paves the way for a promising strategy for biomedical research and clinical diagnostics.
Lu, Zhan; Zhang, Jianyi; Xu, Lizhou; Li, Yanbin; Chen, Siyu; Ye, Zunzhong; Wang, Jianping
2017-01-01
A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED) to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD) solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD) (nearly 102–103 CFU·mL−1 in food samples). Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens. PMID:28241478
Lu, Zhan; Zhang, Jianyi; Xu, Lizhou; Li, Yanbin; Chen, Siyu; Ye, Zunzhong; Wang, Jianping
2017-02-23
A simple, highly-automated instrument system used for on-site detection of foodborne pathogens based on fluorescence was designed, fabricated, and preliminarily tested in this paper. A corresponding method has been proved effective in our previous studies. This system utilizes a light-emitting diode (LED) to excite fluorescent labels and a spectrometer to record the fluorescence signal from samples. A rotation stage for positioning and switching samples was innovatively designed for high-throughput detection, ten at most in one single run. We also developed software based on LabVIEW for data receiving, processing, and the control of the whole system. In the test of using a pure quantum dot (QD) solution as a standard sample, detection results from this home-made system were highly-relevant with that from a well-commercialized product and even slightly better reproducibility was found. And in the test of three typical kinds of food-borne pathogens, fluorescence signals recorded by this system are highly proportional to the variation of the sample concentration, with a satisfied limit of detection (LOD) (nearly 10²-10³ CFU·mL -1 in food samples). Additionally, this instrument system is low-cost and easy-to-use, showing a promising potential for on-site rapid detection of food-borne pathogens.
Na, Weidan; Liu, Siyu; Liu, Xiaotong; Su, Xingguang
2015-11-01
In this study, we reported a simple and sensitive fluorescence nanosensor for rapid detection of amifostine and alkaline phosphatase (ALP). The novel nanosensor was based on the fluorescence "turn on-off" of CdS quantum dots (QDs). Firstly, Cd(2+) cation could react with S(2-) anion to generate fluorescent CdS QDs in the presence of amifostine. The fluorescence (FL) intensity of amifostine-capped CdS QDs (Amifostine-CdS QDs) was increased with the increasing amounts of amifostine, and could be used for amifostine detection. However, amifostine could be converted to 2-(3-aminopropylamino) ethanethiol (WR1065) in the presence of ALP based on the dephosphorylation of ALP. Under the optimum conditions, the affinity of WR1065 to CdS QDs was weaker than that of amifostine. Therefore the new generation of WR1065-CdS QDs would reduce the FL intensity with the increase of ALP concentration, and the fluorescence of CdS QDs was turn off. The metabolic process of amifostine in the presence of alkaline phosphatase could be also studied via the change of FL intensity of CdS QDs. The present method was cost-effective, convenient, and does not require any complicated synthetic procedures. Copyright © 2015 Elsevier B.V. All rights reserved.
Synthesis and characterization of arsenic-doped cysteine-capped thoria-based nanoparticles
NASA Astrophysics Data System (ADS)
Pereira, F. J.; Díez, M. T.; Aller, A. J.
2013-09-01
Thoria materials have been largely used in the nuclear industry. Nonetheless, fluorescent thoria-based nanoparticles provide additional properties to be applied in other fields. Thoria-based nanoparticles, with and without arsenic and cysteine, were prepared in 1,2-ethanediol aqueous solutions by a simple precipitation procedure. The synthesized thoria-based nanoparticles were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (ED-XRS), Raman spectroscopy, Fourier transform infrared (FT-IR) spectroscopy and fluorescence microscopy. The presence of arsenic and cysteine, as well as the use of a thermal treatment facilitated fluorescence emission of the thoria-based nanoparticles. Arsenic-doped and cysteine-capped thoria-based nanoparticles prepared in 2.5 M 1,2-ethanediol solutions and treated at 348 K showed small crystallite sizes and strong fluorescence. However, thoria nanoparticles subjected to a thermal treatment at 873 K also produced strong fluorescence with a very narrow size distribution and much smaller crystallite sizes, 5 nm being the average size as shown by XRD and TEM. The XRD data indicated that, even after doping of arsenic in the crystal lattice of ThO2, the samples treated at 873 K were phase pure with the fluorite cubic structure. The Raman and FT-IR spectra shown the most characteristics vibrational peaks of cysteine together with other peaks related to the bonds of this molecule to thoria and arsenic when present.
Lian, Xiao; Miao, Tifang; Xu, Xiaoyu; Zhang, Chi; Yan, Bing
2017-11-15
The harm of plastic pollutants for human and environment is being paid more and more attention. Polystyrene (PS) and styrene are toxic compounds used in large quantities in the production of fiberglass reinforced polyesters. In this work, a simple method was designed for independent detecting polystyrene and styrene biomarker (phenylglyoxylic acid, PGA) in serum and urine. We prepared Eu3+ functionalized Sc-based metal-organic frameworks as turn-on fluorescent switch for PGA. The distinct enhanced luminescence is observed from the Eu@MOFs with addition of PGA. The fabricated fluorescent switch has several appealing features including high sensitivity (LOD = 4.16 ppb), quick response time (less than 5s) and broad linear range (0.02mg/mL to 0.5mg/mL). Furthermore, Eu@MOFs exhibits excellent selectivity that it is not affected by congeneric biomarkers. More interestingly, a paper-based probe has been devised. The paper-based fluorescence probe would perform an obvious fluorescence change from navy to red with the variety of PGA content. The practicability of the on-site detection platform for quantitative analysis using a colour scanning APP in smartphone has been also demonstrated by coupled with our proposed paper based fluorescence probe. This work first provides a fast, accurate and sensitive method for independent monitoring PS biomarker PGA, and the paper-based probe exhibit a new idea for design portable and easy to operate sensing devices combine with smartphone. Copyright © 2017 Elsevier B.V. All rights reserved.
A FLUORESCENCE BASED ASSAY FOR DNA DAMAGE INDUCED BY TOXIC INDUSTRIAL CHEMICALS
One of the reported effects for exposure to many of the toxic industrial chemicals is DNA damage. The present study describes a simple, rapid and innovative assay to detect DNA damage resulting from exposure of surrogate DNA to toxic industrial chemicals (acrolein, allylamine, ch...
Wang, Haoping; Kang, Tiantian; Wang, Xiaoju; Feng, Liheng
2018-07-01
A simple Schiff base comprised of tris(2-aminoethyl)amine and salicylaldehyde was designed and synthesized by one-step reaction. Although this compound has poor selectivity for metal ions in acetonitrile, it shows high selectivity and sensitivity detection for Zn(II) ions through adjusting the solvent polarity (the volume ratio of CH 3 CN/H 2 O). In other words, this work provides a facile way to realize a transformation from poor to excellent feature for fluorescent probes. The bonding mode of this probe with Zn(II) ions was verified by 1 H NMR and MS assays. The stoichiometric ratio of the probe with Zn(II) is 1:1 (mole), which matches with the Job-plot assay. The detection limitation of the probe for Zn(II) is up to 1 × 10 -8 mol/L. The electrochemical property of the probe combined with Zn(II) was investigated by cyclic voltammetry method, and the result agreed with the theoretical calculation by the Gaussian 09 software. The probe for Zn(II) could be applied in practical samples and biological systems. The main contribution of this work lies in providing a very simple method to realize the selectivity transformation for poor selective probes. The providing way is a simple, easy and low-cost method for obtaining high selectively fluorescence probes. Copyright © 2018 Elsevier B.V. All rights reserved.
Copper nanoclusters as probes for turn-on fluorescence sensing of L-lysine.
Zhang, Mingming; Qiao, Juan; Zhang, Shufeng; Qi, Li
2018-05-15
Herein, a unique protocol based on copper nanoclusters (CuNCs) probe for turn-on fluorescence sensing of L-lysine was developed. The fluorescent CuNCs with ovalbumin as the stabilizer was prepared by a simple, one-step and green method. When 370 nm was used as the excitation wavelength, the resultant CuNCs exhibited a pale blue fluorescence with the maximum emission at 440 nm. Interestingly, existence of L-lysine evoked the obvious fluorescence intensity increase of CuNCs. The detection limit of the proposed method for L-lysine was 5.5 μM, with a good linear range from 10.0 μM to 1.0 mM (r 2 = 0.999). Moreover, the possible mechanism for enhanced fluorescence intensity of CuNCs by addition of L-lysine was explored and discussed briefly. Further, the as-prepared fluorescent CuNCs was successfully applied in detection of L-lysine in urine. Our results demonstrated that L-lysine could be monitored by the probe, providing new path for construction of CuNCs as fluorescent probes and showing great potential in quantification of L-lysine in real samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Carbon dots-based fluorescent probe for "off-on" sensing of Hg(II) and I⁻.
He, Jiangling; Zhang, Haoran; Zou, Jinliang; Liu, Yingliang; Zhuang, Jianle; Xiao, Yong; Lei, Bingfu
2016-05-15
Herein, we report a simple, one-step reflux method for synthesis of photoluminescent carbon dots (CDs) using citric acid as the carbon source and diethylenetriamine (DETA) as the surface passivation reagent along with a high quantum yield (82.40%), the fluorescence intensity of the CDs was found to be effectively quenched by Hg(II) ions. Upon addition of I(-) to the CDs/Hg(II) complex dispersion, the fluorescence intensity of the CDs was significantly recovered. Furthermore, we developed an "off-on" fluorescence assay for the detection of I(-) using CDs/Hg(II) as a fluorescence probe. This probe enables the selective detection of Hg(II) with a linear range of 0-80 μM and a limit of detection is 0.201 µM and a limit of detection about I(-) is 0.234 µM with a linear range of 0-70 μM. Most importantly, the sensors can be successfully applied to the determination of Hg(II) and I(-) in real lake water and urine of cattles, the "off-on" sensor demonstrates high selectivity, repeatability, stability, which offer this CDs-based "off-on" fluorescent sensor a promising platform for environmental and biological sensing applications. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yue, Xiao-li; Wang, Zhao-qing; Li, Chao-rui; Yang, Zheng-yin
2018-03-01
In this paper, a simple naphthalene-based derivative (HL) has been designed and synthesized as a Al3 +-selective fluorescent chemosensor based on the PET mechanism. HL exhibited high selectivity and sensitivity towards Al3 + over other commonly coexisting metal ions in ethanol with a detection limit of 2.72 nM. The 1:1 binding stoichiometry of the complex (HL-Al3 +) was determined from the Job's plot based on fluorescence titrations and the ESI-MS spectrum data. Moreover, the binding site of HL with Al3 + was assured by the 1H NMR titration experiment. The binding constant (Ka) of the complex (HL-Al3 +) was calculated to be 5.06 × 104 M- 1 according to the Benesi-Hildebrand equation. In addition, the recognizing process of HL towards Al3 + was chemically reversible by adding Na2EDTA. Importantly, HL could directly and rapidly detect aluminum ion through the filter paper without resorting to additional instrumental analysis.
Ellairaja, Sundaram; Shenbagavalli, Kathiravan; Ponmariappan, Sarkaraisamy; Vasantha, Vairathevar Sivasamy
2017-05-15
Bilirubin, a key biomarker for the jaundice and its clinical diagnosis needs a better analytical tool. A novel and simple fluorescent platform based on (2,2'-((1E,1'E)-((6-bromopyridine-2,3-diyl) bis(azanylylidene)) bis(methanylylidene diphenol) (BAMD) was designed. BAMD showed a remarkable fluorescent intensity with a very good quantum yield of 0.85 and lifetime of 870ps. Hence, it was applied for the determination of bilirubin using both colorimetric and fluorimetric techniques in physiological and basic pH. Under optimized experimental conditions, the probe detects bilirubin selectively in the presence of other interfering biomolecules and metal ions. The linear range of detection is 1pM-500µM at pH=7.4 and LOD is 2.8 and 3.3 pM at pH=7.4 and 9.0, respectively, which were reported so far. The probe detects the bilirubin through FRET mechanism. The practical application of the probe was successfully tested in the human blood and urine samples. Based on all above advantages, this simple idea can be applied to design a simple clinical diagnostic tool for jaundice. Copyright © 2016. Published by Elsevier B.V.
Hemoglobin detection using carbon dots as a fluorescence probe.
Barati, Ali; Shamsipur, Mojtaba; Abdollahi, Hamid
2015-09-15
Herein, we have described the application of high fluorescent carbon dots (CDs) without any surface modification as a simple and fast responding fluorescence probe for sensitive and selective determination of hemoglobin (Hb) in the presence of H2O2. Although Hb itself was able to quench the fluorescence of CDs, based on the inner filter effect (IFE) of the protein that affects both excitation and emission spectra of CDs, the presence of H2O2 resulted in further improvement of the sensitivity of Hb detection. The assay is based on the reaction of Hb with H2O2 that generates reactive oxygen species including hydroxyl (OH•) and superoxide (O2(•-)) radicals under heme degradation and/or iron release from Hb and the subsequent reaction of hydroxyl radicals, as strong oxidizing agents, with CDs resulting in high fluorescence quenching. The proposed probe was used for determination of Hb in concentration range of 1-100 nM with a detection limit of 0.4 nM. The method was successfully applied to the determination of Hb in human blood samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Wan, Yi; Sun, Yan; Qi, Peng; Wang, Peng; Zhang, Dun
2014-05-15
Nanomaterial-based 'chemical nose' sensor with sufficient sensing specificity is a useful analytical tool for the detection of toxicologically important substances in complicated biological systems. A sensor array containing three quaternized magnetic nanoparticles (q-MNPs)-fluorescent polymer systems has been designed to identify and quantify bacteria. The bacterial cell membranes disrupt the q-MNP-fluorescent polymer, generating unique fluorescence response array. The response intensity of the array is dependent on the level of displacement determined by the relative q-MNP-fluorescent polymer binding strength and bacteria cells-MNP interaction. These characteristic responses show a highly repeatable bacteria cells and can be differentiated by linear discriminant analysis (LDA). Based on the array response matrix from LDA, our approach has been used to measure bacteria with an accuracy of 87.5% for 10(7) cfu mL(-1) within 20 min. Combined with UV-vis measurement, the method can be successfully performed to identify and detect eight different pathogen samples with an accuracy of 96.8%. The measurement system has a potential for further applications and provides a facile and simple method for the rapid analysis of protein, DNA, and pathogens. Copyright © 2013 Elsevier B.V. All rights reserved.
Strand displacement activated peroxidase activity of hemin for fluorescent DNA sensing.
Wang, Quanbo; Xu, Nan; Gui, Zhen; Lei, Jianping; Ju, Huangxian; Yan, Feng
2015-10-07
To efficiently regulate the catalytic activity of the peroxidase mimic hemin, this work designs a double-stranded DNA probe containing an intermolecular dimer of hemin, whose peroxidase activity can be activated by a DNA strand displacement reaction. The double-stranded probe is prepared by annealing two strands of hemin labelled DNA oligonucleotides. Using the fluorescent oxidation product of tyramine by H2O2 as a tracing molecule, the low peroxidase activity of the hemin dimer ensures a low fluorescence background. The strand displacement reaction of the target DNA dissociates the hemin dimer and thus significantly increases the catalytic activity of hemin to produce a large amount of dityramine for fluorescence signal readout. Based on the strand displacement regulated peroxidase activity, a simple and sensitive homogeneous fluorescent DNA sensing method is proposed. The detection can conveniently be carried out in a 96-well plate within 20 min with a detection limit of 0.18 nM. This method shows high specificity, which can effectively distinguish single-base mismatched DNA from perfectly matched target DNA. The DNA strand displacement regulated catalytic activity of hemin has promising application in the determination of various DNA analytes.
Xu, Wei; Fu, Yanyan; Gao, Yixun; Yao, Junjun; Fan, Tianchi; Zhu, Defeng; He, Qingguo; Cao, Huimin; Cheng, Jiangong
2015-07-11
A simple, highly stable, sensitive and selective fluorescent system for peroxide explosives was developed via an aromatic aldehyde oxidation reaction. The high efficiency arises from its higher HOMO level and multiple H-bonding. The sensitivity is obtained to be 0.1 ppt for H2O2 and 0.2 ppb for TATP.
NASA Astrophysics Data System (ADS)
Dimopoulos, Konstantinos; Marti, Dominik; Andersen, Peter E.
2018-02-01
We want to implement two-photon excitation fluorescence microscopy (TPEFM) into endoscopes, since TPEFM can provide relevant biomarkers for cancer staging and grading in hollow organs, endoscopically accessible through natural orifices. However, many obstacles must be overcome, among others the delivery of short laser pulses to the distal end of the endoscope. To this avail, we present imaging results using an all-fibre dispersion management scheme in a TPEFM setup. The scheme has been conceived by Jespersen et al. in 20101 and relies on the combination of a single mode fibre with normal and a higher order mode fibre with anomalous dispersion properties, fused in series using a long period grating. We show that using this fibre assembly, a simple and robust pulsed laser delivery system without any free-space optics, which is thus suitable for clinical use, can be realised.
In vivo fluorescent detection of Fe-S clusters coordinated by human GRX2.
Hoff, Kevin G; Culler, Stephanie J; Nguyen, Peter Q; McGuire, Ryan M; Silberg, Jonathan J; Smolke, Christina D
2009-12-24
A major challenge to studying Fe-S cluster biosynthesis in higher eukaryotes is the lack of simple tools for imaging metallocluster binding to proteins. We describe the first fluorescent approach for in vivo detection of 2Fe2S clusters that is based upon the complementation of Venus fluorescent protein fragments via human glutaredoxin 2 (GRX2) coordination of a 2Fe2S cluster. We show that Escherichia coli and mammalian cells expressing Venus fragments fused to GRX2 exhibit greater fluorescence than cells expressing fragments fused to a C37A mutant that cannot coordinate a metallocluster. In addition, we find that maximal fluorescence in the cytosol of mammalian cells requires the iron-sulfur cluster assembly proteins ISCU and NFS1. These findings provide evidence that glutaredoxins can dimerize within mammalian cells through coordination of a 2Fe2S cluster as observed with purified recombinant proteins. Copyright 2009 Elsevier Ltd. All rights reserved.
Sakaguchi, Yohei; Yoshida, Hideyuki; Todoroki, Kenichiro; Nohta, Hitoshi; Yamaguchi, Masatoshi
2009-06-15
We have developed a new and simple method based on "fluorous derivatization" for LC of native fluorescent compounds. This method involves the use of a column with a fluorous stationary phase. Native fluorescent analytes with target functional groups are precolumn derivatized with a nonfluorescent fluorous tag, and the fluorous-labeled analytes are retained in the column, whereas underivatized substances are not. Only the retained fluorescent analytes are detected fluorometrically at appropriate retention times, and retained substrates without fluorophores are not detected. In this study, biologically important carboxylic acids (homovanillic acid, vanillylmandelic acid, and 5-hydroxyindoleacetic acid) and drugs (naproxen, felbinac, flurbiprofen, and etodolac) were used as model native fluorescent compounds. Experimental results indicate that the fluorous-phase column can selectively retain fluorous compounds including fluorous-labeled analytes on the basis of fluorous separation. We believe that separation-oriented derivatization presented here is the first step toward the introduction of fluorous derivatization in quantitative LC analysis.
NASA Astrophysics Data System (ADS)
Hun, Xu; Zhang, Zhujun
2009-10-01
Fluorescent nanoparticles (FNs) with unique optical properties may be useful as biosensors in living cancer cell imaging and cancer targeting. In this study, anti-EGFR antibody conjugated fluorescent nanoparticles (FNs) (anti-EGFR antibody conjugated FNs) probe was used to detect breast cancer cells. FNs with excellent character such as non-toxicity and photostability were first synthesized with a simple, cost-effective and environmentally friendly modified Stőber synthesis method, and then successfully modified with anti-EGFR antibody. This kind of fluorescence probe based on the anti-EGFR antibody conjugated FNs has been used to detect breast cancer cells with fluorescence microscopy imaging technology. The experimental results demonstrate that the anti-EGFR antibody conjugated FNs can effectively recognize breast cancer cells and exhibited good sensitivity and exceptional photostability, which would provide a novel way for the diagnosis and curative effect observation of breast cancer cells and offer a new method in detecting EGFR.
Fluorescence-tunable Ag-DNA biosensor with tailored cytotoxicity for live-cell applications
NASA Astrophysics Data System (ADS)
Bossert, Nelli; de Bruin, Donny; Götz, Maria; Bouwmeester, Dirk; Heinrich, Doris
2016-11-01
DNA-stabilized silver clusters (Ag-DNA) show excellent promise as a multi-functional nanoagent for molecular investigations in living cells. The unique properties of these fluorescent nanomaterials allow for intracellular optical sensors with tunable cytotoxicity based on simple modifications of the DNA sequences. Three Ag-DNA nanoagent designs are investigated, exhibiting optical responses to the intracellular environments and sensing-capability of ions, functional inside living cells. Their sequence-dependent fluorescence responses inside living cells include (1) a strong splitting of the fluorescence peak for a DNA hairpin construct, (2) an excitation and emission shift of up to 120 nm for a single-stranded DNA construct, and (3) a sequence robust in fluorescence properties. Additionally, the cytotoxicity of these Ag-DNA constructs is tunable, ranging from highly cytotoxic to biocompatible Ag-DNA, independent of their optical sensing capability. Thus, Ag-DNA represents a versatile live-cell nanoagent addressable towards anti-cancer, patient-specific and anti-bacterial applications.
Ullrich, Thomas; Ermantraut, Eugen; Schulz, Torsten; Steinmetzer, Katrin
2012-01-01
Background State of the art molecular diagnostic tests are based on the sensitive detection and quantification of nucleic acids. However, currently established diagnostic tests are characterized by elaborate and expensive technical solutions hindering the development of simple, affordable and compact point-of-care molecular tests. Methodology and Principal Findings The described competitive reporter monitored amplification allows the simultaneous amplification and quantification of multiple nucleic acid targets by polymerase chain reaction. Target quantification is accomplished by real-time detection of amplified nucleic acids utilizing a capture probe array and specific reporter probes. The reporter probes are fluorescently labeled oligonucleotides that are complementary to the respective capture probes on the array and to the respective sites of the target nucleic acids in solution. Capture probes and amplified target compete for reporter probes. Increasing amplicon concentration leads to decreased fluorescence signal at the respective capture probe position on the array which is measured after each cycle of amplification. In order to observe reporter probe hybridization in real-time without any additional washing steps, we have developed a mechanical fluorescence background displacement technique. Conclusions and Significance The system presented in this paper enables simultaneous detection and quantification of multiple targets. Moreover, the presented fluorescence background displacement technique provides a generic solution for real time monitoring of binding events of fluorescently labelled ligands to surface immobilized probes. With the model assay for the detection of human immunodeficiency virus type 1 and 2 (HIV 1/2), we have been able to observe the amplification kinetics of five targets simultaneously and accommodate two additional hybridization controls with a simple instrument set-up. The ability to accommodate multiple controls and targets into a single assay and to perform the assay on simple and robust instrumentation is a prerequisite for the development of novel molecular point of care tests. PMID:22539973
Zeinhom, Mohamed Maarouf Ali; Wang, Yijia; Song, Yang; Zhu, Mei-Jun; Lin, Yuehe; Du, Dan
2018-01-15
The detection of E. coli O157:H7 in foods has held the attention of many researchers because of the seriousness attributed to this pathogen. In this study, we present a simple, sensitive, rapid and portable smartphone based fluorescence device for E. coli O157:H7 detection. This field-portable fluorescent imager on the smartphone involves a compact laser-diode-based photosource, a long-pass (LP) thin-film interference filter and a high-quality insert lenses. The design of the device provided a low noise to background imaging system. Based on a sandwich ELISA and the specific recognition of antibody to E. coli O157:H7, the sensitive detection of E. coli O157:H7 were realized both in standard samples and real matrix in yoghurt and egg on our device. The detection limit are 1 CFU/mL and 10 CFU/mL correspondingly. Recovery percentages of spiked yogurt and egg samples with 10 3 , 10 4 and 10 5 CFU/mL E. coli O157:H7 were 106.98, 96.52 and 102.65 (in yogurt) and 107.37, 105.64 and 93.84 (in egg) samples using our device, respectively. Most importantly, the entire process could be quickly completed within two hours. This smartphone based device provides a simple, rapid, sensitive detection platform for fluorescent imaging which applied in pathogen detection for food safety monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Sensor Systems for Biological Agent Attacks: Protecting Buildings and Military Bases
2004-01-01
simple aerosol detectors, to those that identify an agent based on its genetic, structural, or chemical properties , to so- called "functional...Cytometry, 122 Target Binding That Changes Detectable Properties of Smart Sensor Surfaces, 124 Colorimetric Detection, 124 Fluorescence Detection, 125 One...microscopy. In addition to particles directly derived from living organisms, other particles in air may also share properties with the bioaerosols
Determining absolute protein numbers by quantitative fluorescence microscopy.
Verdaasdonk, Jolien Suzanne; Lawrimore, Josh; Bloom, Kerry
2014-01-01
Biological questions are increasingly being addressed using a wide range of quantitative analytical tools to examine protein complex composition. Knowledge of the absolute number of proteins present provides insights into organization, function, and maintenance and is used in mathematical modeling of complex cellular dynamics. In this chapter, we outline and describe three microscopy-based methods for determining absolute protein numbers--fluorescence correlation spectroscopy, stepwise photobleaching, and ratiometric comparison of fluorescence intensity to known standards. In addition, we discuss the various fluorescently labeled proteins that have been used as standards for both stepwise photobleaching and ratiometric comparison analysis. A detailed procedure for determining absolute protein number by ratiometric comparison is outlined in the second half of this chapter. Counting proteins by quantitative microscopy is a relatively simple yet very powerful analytical tool that will increase our understanding of protein complex composition. © 2014 Elsevier Inc. All rights reserved.
Green synthesis of carbon dots from pork and application as nanosensors for uric acid detection
NASA Astrophysics Data System (ADS)
Zhao, Chunxi; Jiao, Yang; Hu, Feng; Yang, Yaling
2018-02-01
In this work, a green, simple, economical method was developed in the synthesis of fluorescent carbon dots using pork as carbon source. The as-prepared carbon dots exhibit exceptional advantages including high fluorescent quantum yield (17.3%) and satisfactory chemical stability. The fluorescence of carbon dots based nanosensor can be selectively and efficiently quenched by uric acid. This phenomenon was used to develop a fluorescent method for facile detection of uric acid within a linear range of 0.1-100 μM and 100-500 μM, with a detection limit of 0.05 μM (S/N = 3). Finally, the proposed method was successfully applied in the determination of uric acid in human serum and urine samples with satisfactory recoveries, which suggested that the new nanosensors have great prospect toward the detection of uric acid in human fluids.
Aqueous synthesis of near-infrared highly fluorescent platinum nanoclusters
NASA Astrophysics Data System (ADS)
García Fernández, Jenifer; Trapiella-Alfonso, Laura; Costa-Fernández, José M.; Pereiro, Rosario; Sanz-Medel, Alfredo
2015-05-01
A one-step synthesis of near infrared fluorescent platinum nanoclusters (PtNCs) in aqueous medium is described. The proposed optimized procedure for PtNC synthesis is rather simple, fast and it is based on the direct metal reduction with NaBH4. Bidentated thiol ligands (lipoic acid) were selected as nanoclusters stabilizers in water media. The structural characterization revealed attractive features of the PtNCs, including small size, high water solubility, near-infrared luminescence centered at 680 nm, long-term stability and the highest quantum yield in water reported so far (47%) for PtNCs. Moreover, their stability in different pH media and an ionic strength of 0.2 M NaCl was studied and no significant changes in fluorescence emission were detected. In brief, they offer a new type of fluorescent noble metal nanoprobe with a great potential to be applied in several fields, including biolabeling and imaging experiments.
Lin, Zhijin; Luo, Fenqiang; Dong, Tongqing; Zheng, Liyan; Wang, Yaxian; Chi, Yuwu; Chen, Guonan
2012-05-21
Recently, metal-selective fluorescent chemosensors have attracted intense attention for their simple and real-time tracking of metal ions in environmental samples. However, most of the existing fluorescent sensors are one-off sensors and thus suffer from large amount of reagent consumption, significant experimental cost and raising the risk of environmental pollution. In this paper, we developed a green (low reagent consumption, low-toxicity reagent use), recyclable, and visual sensor for Cu(2+) in aqueous solution by using a fluorescent gold nanoclusters membrane (FGM) as the sensing unit, basing on our findings on gold nanoclusters (Au NCs) that the bovine serum albumin (BSA)-coated Au NCs exhibit excellent membrane-forming ability under the isoelectric point of BSA, and thus enable us to obtain a new type of sensing membrane (i.e. FGM) by denaturing Au NCs; the fluorescence of FGM can be significantly quenched by Cu(2+) ion, and the quenched fluorescence can be totally recovered by histidine; the as-prepared FGM is very stable and recyclable, which makes it an ideal sensing material.
NASA Astrophysics Data System (ADS)
Bollgruen, Patrick; Gleissner, Uwe; Wolfer, Tim; Megnin, Christof; Mager, Dario; Overmeyer, Ludger; Korvink, Jan G.; Hanemann, Thomas
2016-10-01
Polymer-based optical sensor networks on foils (planar optronic systems) are a promising research field, but it can be challenging to supply them with light. We present a solvent-free, ink-jet printable material system with optically active substances to create planar light sources for these networks. The ink is based on a UV-curable monomer, the fluorescent agents are EuDBMPhen or 9,10-diphenylantracene, which fluoresce at 612 or 430 nm, respectively. We demonstrate the application as light source by printing a small area of fluorescent material on an optical waveguide fabricated by flexographic printing on PMMA foil, resulting in a simple polymer-optical device fabricated entirely by additive deposition techniques. When excited by a 405-nm laser of 10 mW, the emitted light couples into the waveguide and appears at the end of the waveguide. In comparison to conventional light sources, the intensity is weak but could be detected with a photodiode power sensor. In return, the concept has the advantage of being completely independent of any electrical elements or external cable connections.
Gaikwad, Ravi M.; Dokukin, Maxim E.; Iyer, K. Swaminathan; Woodworth, Craig D.; Volkov, Dmytro O.; Sokolov, Igor
2012-01-01
Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical interaction between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells. PMID:21305062
Medically relevant assays with a simple smartphone and tablet based fluorescence detection system.
Wargocki, Piotr; Deng, Wei; Anwer, Ayad G; Goldys, Ewa M
2015-05-20
Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.
Yuan, Chao; Liu, Bianhua; Liu, Fei; Han, Ming-Yong; Zhang, Zhongping
2014-01-21
A new "turn on" fluorescence nanosensor for selective Hg(2+) determination is reported based on bis(dithiocarbamato)copper(II) functionalized carbon nanodots (CuDTC2-CDs). The CuDTC2 complex was conjugated to the prepared amine-coated CDs by the condensation of carbon disulfide onto the nitrogen atoms in the surface amine groups, followed by the coordination of copper(II) to the resulting dithiocarbamate groups (DTC) and finally by the additional coordination of ammonium N-(dithicarbaxy) sarcosine (DTCS) to form the CuDTC2-complexing CDs. The CuDTC2 complex at surface strongly quenched the bright-blue fluorescence of the CDs by a combination of electron transfer and energy transfer mechanism. Hg(2+) could immediately switch on the fluorescence of the CuDTC2-CDs by promptly displacing the Cu(2+) in the CuDTC2 complex and thus shutting down the energy transfer pathway, in which the sensitive limit for Hg(2+) as low as 4 ppb was reached. Moreover, a paper-based sensor has been fabricated by printing the CuDTC2-CDs probe ink on a piece of cellulose acetate paper using a commercial inkjet printer. The fluorescence "turn on" on the paper provided the most conveniently visual detection of aqueous Hg(2+) ions by the observation with naked eye. The very simple and effective strategy reported here facilitates the development of portable and reliable fluorescence nanosensors for the determination of Hg(2+) in real samples.
Bioconjugated fluorescent silica nanoparticles for the rapid detection of Entamoeba histolytica.
Hemadi, Ahmad; Ekrami, Alireza; Oormazdi, Hormozd; Meamar, Ahmad Reza; Akhlaghi, Lame; Samarbaf-Zadeh, Ali Reza; Razmjou, Elham
2015-05-01
Rapid detection of Entamoeba histolytica based on fluorescent silica nanoparticle (FSNP) indirect immunofluorescence microscopy was evaluated. Silica nanoparticles were synthesized using Stöber's method, with their surface activated to covalently bind to, and immobilize, protein A. For biolabeling, FSNP was added to conjugated E. histolytica trophozoites with monoclonal anti-E. histolytica IgG1 for microscopic observation of fluorescence. Fluorescent silica nanoparticle sensitivity was determined with axenically cultured E. histolytica serially diluted to seven concentrations. Specificity was evaluated using other intestinal protozoa. Fluorescent silica nanoparticles detected E. histolytica at the lowest tested concentration with no cross-reaction with Entamoeba dispar, Entamoeba moshkovskii, Blastocystis sp., or Giardia lamblia. Visualization of E. histolytica trophozoites with anti-E. histolytica antibody labeled with fluorescein isothiocyanate (FITC) was compared with that using anti-E. histolytica antibody bioconjugated FSNP. Although FITC and FSNP produced similar results, the amount of specific antibody required for FITC to induce fluorescence of similar intensity was fivefold that for FSNP. Fluorescent silica nanoparticles delivered a rapid, simple, cost-effective, and highly sensitive and specific method of detecting E. histolytica. Further study is needed before introducing FSNP for laboratory diagnosis of amoebiasis. Copyright © 2015 Elsevier B.V. All rights reserved.
AN INVESTIGATION OF THE BENZOIN METHOD FOR THE FLUORIMETRIC DETERMINATION OF BORON
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, G.; Radley, J.A.
1961-01-01
The development of the boron -benzoin fluorescence at microgram concentrations of boron was investigated; a simple, but sensitive, fluorimeter was used. The development and decay of fluorescence intensity with time were observed in various solvents in the presence of different basic compounds. The fluorescence produced when formamide and its N-derivatives are used as the solvent media is stronger than that found when ethanol is used. A glycine buffer solution of pH 12.8 is effective in producing the correct conditions for developing fluorescence with ethanol as solvent, but is not effective in the formamide series of solvents. Isopropylamine and isobutylamine aremore » effective bases in both ethanol and the formamide series. For a series of solvents of a given chemical type, e.g., the formamides, there may be an increase in fluorescence intensity with dielectric constant, although this is not true for the alcohols. Oxygen has a pronounced inhibiting action on the development of fluorescence in ethanol, but has much less effect in formamide. There is a linear relationship between fluorescence intensity and amount of boron present in the range studied (0.05 to 0.5 - g). (auth)« less
Duong, Hong Dinh; Rhee, Jong Il
2017-11-08
In this study, the oxazine 170 perchlorate (O17)-ethylcellulose (EC) membrane was successfully exploited for the fabrication of creatine- and creatinine-sensing membranes. The sensing membrane exhibited a double layer of O17-EC membrane and a layer of enzyme(s) entrapped in the EC and polyurethane hydrogel (PU) matrix. The sensing principle of the membranes was based on the hydrolytic catalysis of urea, creatine, and creatinine by the enzymes. The reaction end product, ammonia, reacted with O17-EC membrane, resulting in the change in fluorescence intensities at two emission wavelengths ( λ em = 565 and 625 nm). Data collected from the ratio of fluorescence intensities at λ em = 565 and 625 nm were proportional to the concentrations of creatine or creatinine. Creatine- and creatinine-sensing membranes were very sensitive to creatine and creatinine at the concentration range of 0.1-1.0 mM, with a limit of detection (LOD) of 0.015 and 0.0325 mM, respectively. Furthermore, these sensing membranes showed good features in terms of response time, reversibility, and long-term stability. The interference study demonstrated that some components such as amino acids and salts had some negative effects on the analytical performance of the membranes. Thus, the simple and sensitive ratiometric fluorescent sensors provide a simple and comprehensive method for the determination of creatine and creatinine concentrations in urine.
Duong, Hong Dinh; Rhee, Jong Il
2017-01-01
In this study, the oxazine 170 perchlorate (O17)-ethylcellulose (EC) membrane was successfully exploited for the fabrication of creatine- and creatinine-sensing membranes. The sensing membrane exhibited a double layer of O17-EC membrane and a layer of enzyme(s) entrapped in the EC and polyurethane hydrogel (PU) matrix. The sensing principle of the membranes was based on the hydrolytic catalysis of urea, creatine, and creatinine by the enzymes. The reaction end product, ammonia, reacted with O17-EC membrane, resulting in the change in fluorescence intensities at two emission wavelengths (λem = 565 and 625 nm). Data collected from the ratio of fluorescence intensities at λem = 565 and 625 nm were proportional to the concentrations of creatine or creatinine. Creatine- and creatinine-sensing membranes were very sensitive to creatine and creatinine at the concentration range of 0.1–1.0 mM, with a limit of detection (LOD) of 0.015 and 0.0325 mM, respectively. Furthermore, these sensing membranes showed good features in terms of response time, reversibility, and long-term stability. The interference study demonstrated that some components such as amino acids and salts had some negative effects on the analytical performance of the membranes. Thus, the simple and sensitive ratiometric fluorescent sensors provide a simple and comprehensive method for the determination of creatine and creatinine concentrations in urine. PMID:29117119
Digman, Michelle A.; Gratton, Enrico; Storti, Barbara; Beltram, Fabio
2013-01-01
A versatile pH-dependent fluorescent protein was applied to intracellular pH measurements by means of the phasor approach to fluorescence lifetime imaging. By this fit-less method we obtain intracellular pH maps under resting or altered physiological conditions by single-photon confocal or two-photon microscopy. PMID:22517076
Wang, Ting; Zhang, Kun-He; Hu, Piao-Ping; Huang, Zeng-Yong; Zhang, Pan; Wan, Qin-Si; Huang, De-Qiang; Lv, Nong-Hua
2016-09-27
The diagnosis of early, small and alpha-fetoprotein (AFP)-negative primary hepatic carcinomas (PHCs) remains a significant challenge. We developed a simple and robust approach to noninvasively detect these PHCs. A rapid, high-throughput and single-tube method was firstly developed to measure serum autofluorescence and cell-free DNA (cfDNA)-related fluorescence using a real-time PCR system, and both types of serum fluorescence were measured and routine laboratory data were collected in 1229 subjects, including 353 PHC patients, 331 liver cirrhosis (LC) patients, 213 chronic hepatitis (CH) patients and 332 normal controls (NC). The results showed that fluorescence indicators of PHC differed from those of NC, CH and LC to various extents, and all of them were not associated with age, gender, or AFP level. The logistic regression models established with the fluorescence indicators alone and combined with AFP, hepatic function tests and blood cell analyses were valuable for distinguishing early, small, AFP-negative and all PHC from LC, CH, NC and all non-PHC, with areas under the receiver operating characteristic curves 0.857-0.993 and diagnostic accuracies 80.2-97.7%. Conclusively, serum autofluorescence and cfDNA-related fluorescence are able to be rapidly and simultaneously measured by our simple method and valuable for diagnosing early, small and AFP-negative PHCs, especially integrating with AFP and conventional blood tests.
Zhang, Kui; Mei, Qingsong; Guan, Guijian; Liu, Bianhua; Wang, Suhua; Zhang, Zhongping
2010-11-15
The development of a simple and on-site assay for the detection of organophosphorus pesticed residues is very important for food safety and exosystem protection. This paper reports the surface coordination-originated fluorescence resonance energy transfer (FRET) of CdTe quantum dots (QDs) and a simple ligand-replacement turn-on mechanism for the highly sensitive and selective detection of organophosphorothioate pesticides. It has been demonstrated that coordination of dithizone at the surface of CdTe QDs in basic media can strongly quench the green emission of CdTe QDs by a FRET mechanism. Upon the addition of organophosphorothioate pesticides, the dithizone ligands at the CdTe QD surface are replaced by the hydrolyzate of the organophosphorothioate, and hence the fluorescence is turned on. The fluorescence turn on is immediate, and the limit of detection for chlorpyrifos is as low as ∼0.1 nM. Two consecutive linear ranges allow a wide determination of chlorpyrifos concentrations from 0.1 nM to 10 μM. Importantly, the fluorescence turn-on chemosensor can directly detect chlorpyrifos residues in apples at a limit of 5.5 ppb, which is under the maximum residue limit allowed by the U.S. Environmental Protection Agency. The very simple strategy reported here should facilitate the development of fluorescence turn-on chemosensors for chemo/biodetection.
A Colorimetric and Fluorescent Probe for the Detection of Cu2+ in a Complete Aqueous Solution.
Xu, Jing; Wang, Zuokai; Liu, Caiyun; Xu, Zhenghe; Zhu, Baocun; Wang, Ning; Wang, Kun; Wang, Jiangting
2018-01-01
The fluorescent probe has become an important method for the detection of heavy metal ions. In the present work, a new and simple fluorescent probe, Cu-P, for detecting copper ion (Cu 2+ ) was designed and synthesized. The probe has shown high sensitivity and selectivity toward Cu 2+ . The detection limit was 13 nM (based on the 3σ/slope). A significant color change from yellow to pink was observed; thus, the probe Cu-P could serve as a "naked-eye" indicator for Cu 2+ . Furthermore, the proposed probe was used to detect Cu 2+ in real water and soil extract samples, with the result being satisfactory. Therefore, our proposed probe would provide a promising method for the detection of Cu 2+ in the environment.
Quinoline containing acetyl hydrazone: An easily accessible switch-on optical chemosensor for Zn2.
Wu, Wei-Na; Mao, Pan-Dong; Wang, Yuan; Zhao, Xiao-Lei; Xu, Zhou-Qing; Xu, Zhi-Hong; Xue, Yuan
2018-01-05
A simple chemosensor, namely, N-((quinolin-8-yl)methylene)acetohydrazide (1) was synthesized and used as an off-on fluorescence sensor, which exhibits high selectivity toward Zn 2+ in aqueous media. The probe has large Stokes shift of >200nm, and its detection limit for Zn 2+ is 89.3nM. The binding process was confirmed through UV-vis absorption analysis, fluorescence measurements, mass spectroscopy study, 1 H NMR spectra and density functional theory calculation. The crystal structures of Zn 2+ , Ni 2+ , and Cu 2+ complexes based on 1 were determined through X-ray crystallographic analysis. The fluorescent probe was then applied to monitor intracellular Zn 2+ in HeLa cells. Copyright © 2017 Elsevier B.V. All rights reserved.
Patil, Kishor S; Mahajan, Prasad G; Patil, Shivajirao R
2017-01-05
The fluorescent 2-[(E)-(2-phenylhydrazinylidene)methyl]phenol nanoparticles (PHPNPs) were prepared by a simple reprecipitation method. The prepared PHPNPs examined by Dynamic Light Scattering show narrower particle size distribution having an average particle size of 93.3nm. The Scanning Electron Microphotograph shows distinct spherical shaped morphology of nanoparticles. The blue shift in UV-absorption and fluorescence spectra of PHPNPs with respect to corresponding spectra of PHP in acetone solution indicates H- aggregates and Aggregation Induced Enhanced Emission (AIEE) for nanoparticles. The nanoparticles show selective tendency towards the recognition of Sn(2+) ions by enhancing the fluorescence intensity preference to Cu(2+), Fe(3+), Fe(2+), Ni(2+), NH4(+), Ca(2+), Pb(2+), Hg(2+) and Zn(2+) ions, which actually seem to quench the fluorescence of nanoparticles. The studies on Langmuir adsorption plot, fluorescence lifetime of PHPNPs, DLS-Zeta sizer, UV-visible and fluorescence titration with and without Sn(2+) helped to propose a suitable mechanism of fluorescence enhancement of nanoparticles by Sn(2+) and their binding ability during complexation. The fluorescence enhancement effect of PHPNPs induced by Sn(2+) is further used to develop an analytical method for detection of Sn(2+) from aqueous medium in environmental samples. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Patil, Kishor S.; Mahajan, Prasad G.; Patil, Shivajirao R.
2017-01-01
The fluorescent 2-[(E)-(2-phenylhydrazinylidene)methyl]phenol nanoparticles (PHPNPs) were prepared by a simple reprecipitation method. The prepared PHPNPs examined by Dynamic Light Scattering show narrower particle size distribution having an average particle size of 93.3 nm. The Scanning Electron Microphotograph shows distinct spherical shaped morphology of nanoparticles. The blue shift in UV-absorption and fluorescence spectra of PHPNPs with respect to corresponding spectra of PHP in acetone solution indicates H- aggregates and Aggregation Induced Enhanced Emission (AIEE) for nanoparticles. The nanoparticles show selective tendency towards the recognition of Sn2 + ions by enhancing the fluorescence intensity preference to Cu2 +, Fe3 +, Fe2 +, Ni2 +, NH4+, Ca2 +, Pb2 +, Hg2 + and Zn2 + ions, which actually seem to quench the fluorescence of nanoparticles. The studies on Langmuir adsorption plot, fluorescence lifetime of PHPNPs, DLS-Zeta sizer, UV-visible and fluorescence titration with and without Sn2 + helped to propose a suitable mechanism of fluorescence enhancement of nanoparticles by Sn2 + and their binding ability during complexation. The fluorescence enhancement effect of PHPNPs induced by Sn2 + is further used to develop an analytical method for detection of Sn2 + from aqueous medium in environmental samples.
NASA Astrophysics Data System (ADS)
Liu, Haijian; Li, Ming; Jiang, Linye; Shen, Feng; Hu, Yufeng; Ren, Xueqin
2017-02-01
Arginine plays an important role in many biological functions, whose detection is very significant. Herein, a sensitive, simple and cost-effective fluorescent method for the detection of arginine has been developed based on the inner filter effect (IFE) of citrate-stabilized gold nanoparticles (AuNPs) on the fluorescence of thioglycolic acid-capped CdTe quantum dots (QDs). When citrate-stabilized AuNPs were mixed with thioglycolic acid-capped CdTe QDs, the fluorescence of CdTe QDs was significantly quenched by AuNPs via the IFE. With the presence of arginine, arginine could induce the aggregation and corresponding absorption spectra change of AuNPs, which then IFE-decreased fluorescence could gradually recover with increasing amounts of arginine, achieving fluorescence ;turn on; sensing for arginine. The detection mechanism is clearly illustrated and various experimental conditions were also optimized. Under the optimum conditions, a decent linear relationship was obtained in the range from 16 to 121 μg L- 1 and the limit of detection was 5.6 μg L- 1. And satisfactory results were achieved in arginine analysis using arginine injection, compound amino acid injection, even blood plasma as samples. Therefore, the present assay showed various merits, such as simplicity, low cost, high sensitivity and selectivity, making it promising for sensing arginine in biological samples.
Zhao, Liu; Miao, Yanqing; Liu, Chunye; Zhang, Chenxiao
2016-01-01
The detection of pyrophosphatase (PPase) activity is of great significance in diagnosing diseases and understanding the function of PPase-related biological events. This study constructed a turn off-on-off fluorescent system for PPase activity assay based on PPase-regulated competitive coordination of Cu2+ between a water-soluble fluorescent probe 6,7-dihydroxycoumarin (DHC) and pyrophosphate (PPi). The probe DHC can coordinate with Cu2+ and consequently display on-off type fluorescence response. Furthermore, the in situ formed nonfluorescent Cu2+-DHC complex can act as an effective off-on type fluorescent probe for sensing PPi due to the higher coordination reactivity between Cu2+ and PPi than that between Cu2+ and DHC. The subsequent addition of PPase to the mixture containing Cu2+, DHC, and PPi leads to the fluorescence requenching of the system again (an off state) because PPase catalyzes the hydrolysis of PPi into orthophosphate in the reaction system. Under the optimum conditions, the decrease of the fluorescence intensity of DHC-Cu2+-PPi system was linear with the increase of the PPase activity in the range from 0.1 to 0.3 U. The detection limit was down to 0.028 U PPase (S/N = 3). Moreover, the as-established system was also applied to evaluate PPase inhibitor. This study offers a simple yet effective method for the detection of PPase activity. PMID:27766179
Chen, Hua-Yan; Wei, Jing-Ru; Pan, Jiong-Xiu; Zhang, Wei; Dang, Fu-Quan; Zhang, Zhi-Qi; Zhang, Jing
2017-05-15
5-hydroxymethylcytosine (5hmC) is the sixth base of DNA. It is involved in active DNA demethylation and can be a marker of diseases such as cancer. In this study, we developed a simple and sensitive 2-(4-boronophenyl)quinoline-4-carboxylic acid modified poly (glycidyl methacrylate (PBAQA-PGMA) fluorescent probe to detect the 5hmC content of genomic DNA based on T4 β-glucosyltransferase-catalyzed glucosylation of 5hmC. The fluorescence-enhanced intensity recorded from the DNA sample was proportional to its 5-hydroxymethylcytosine content and could be quantified by fluorescence spectrophotometry. The developed probe showed good detection sensitivity and selectivity and a good linear relationship between the fluorescence intensity and the concentration of 5 hmC within a 0-100nM range. Compared with other fluorescence detection methods, this method not only could determine trace amounts of 5 hmC from genomic DNA but also could eliminate the interference of fluorescent dyes and the need for purification. It also could avoid multiple labeling. Because the PBAQA-PGMA probe could enrich the content of glycosyl-5-hydroxymethyl-2-deoxycytidine from a complex ground substance, it will broaden the linear detection range and improve sensitivity. The limit of detection was calculated to be 0.167nM after enrichment. Furthermore, the method was successfully used to detect 5-hydroxymethylcytosine from mouse tissues. Copyright © 2016 Elsevier B.V. All rights reserved.
Wang, Ye; Gan, Ning; Zhou, You; Li, Tianhua; Cao, Yuting; Chen, Yinji
2017-01-15
Herein, a smart single-stranded DNA binding protein (SSB)-assisted fluorescence aptamer switch based on fluorescence resonance energy transfer (FRET) was designed. The FRET switch was synthesized by connecting SSB labeled quantum dots (QDs@SSB) as donor with aptamer (apt) labeled gold nanoparticles (AuNPs@apt) as acceptor, and it was employed for detecting chloramphenicol (CAP) in a homogenous solution. In the assay, the interaction between core-shell QDs@SSB and AuNPs@apt leads to a dramatic quenching (turning off). After adding CAP in the detection system, AuNPs@apt can bind the target specifically then separate QDs@SSB with AuNPs@apt-target, resulting in restoring the fluorescence intensity of QDs (turning on). Consequently, the fluorescence intensity recovers and the recovery extent can be used for detection of CAP in homogenous phase via optical responses. Under optimal conditions, the fluorescence intensity increased linearly with increasing concentrations of CAP from 0.005 to 100ngmL -1 . The limit of this fluorescence aptamer switch was around 3pgmL -1 for CAP detection. When the analyte is changed, the assay can be applied to detect other targets only by changing relative aptamer in AuNPs@apt probe. Furthermore, it has potential to be served as a simple, sensitive and portable platform for antibiotic contaminants detection in biological and environmental samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Vanlı, Elvan; Mısır, Miraç Nedim; Alp, Hakan; Ak, Tuğba; Özbek, Nurhayat; Ocak, Ümmühan; Ocak, Miraç
2017-09-01
Four fluorescent Schiff bases carrying dipicolylamine groups were designed and synthesized to determine their ion sensor properties in partial aqueous solution. The corresponding amine compound and the aldehyde compounds such as 1-naphthaldehyde, 9-anthraldehyde, phenanthrene-9-carboxaldehyde and 1-pyrenecarboxaldehyde were used to prepare the new Schiff bases. The influence of many metal cations and anions on the spectroscopic properties of the ligands was investigated in ethanol-water (1:1) by means of emission spectrometry. From the spectrofluorimetric titrations, the complexation stoichiometry and complex stability constants of the ligands with Cd 2+ , Zn 2+ , Cu 2+ and Hg 2+ ions were determined. The ligands did not interact with the anions. However, the Schiff base derived from phenanthrene-9-carboxaldehyde showed sensitivity for Cu 2+ among the tested metal ions. The phenanthrene-based Schiff base was used as analytical ligand for the simple and fast determination of Cu 2+ ion in water samples. A modified standard addition method was used to eliminate matrix effect. The linear range was from 0.3 mg/L to 3.8 μg/L. Detection and quantification limits were 0.14 and 0.43 mg/L, respectively. Maximum contaminant level goal (MCLG) for copper in drinking water according to EPA is 1.3 mg/L. The proposed method has high sensitivity to determine copper in drinking waters.
In situ optical measurements for characterization of flame species and remote sensing
NASA Astrophysics Data System (ADS)
Cullum, Brian Michael
1998-12-01
The following dissertation describes the use of spectroscopic techniques for both characterization of combustion intermediates and remote chemical sensing. The primary techniques that have been used for these measurements include, laser-induced fluorescence (LIF), time resolved LIF, resonance enhanced multiphoton ionization (REMPI) and Raman spectroscopy. A simple and quantitative means of measuring the efficiency of halogenated flame retardants is described, using laser-induced fluorescence (LIF). Intensity based LIF measurements of OH radical have been used to quantitatively measure the efficacy of halogenated flame retardant/polymer plaques. Temporally resolved LIF has been used to determine the extent to which the chemical kinetic theory of flame retardation applies to the effect of these compounds on combustion. We have shown that LIF of OH radicals is a very sensitive means of measuring the efficiency of these flame retardants as well as the giving information about the nature of flame retardation. In addition, we have developed a technique for the introduction of insoluble polymer plaques into a flame for fluorescence analysis. A high power pulsed Nd:YAG laser is used to ablate the sample into the flame while a second pulse from a dye laser is used to measure the LIF of OH radicals. Spectroscopic techniques are also very useful for trace remote analysis of environmental pollutants via optical fibers. A simple fiber-optic probe suitable for remote analysis using resonance enhanced multiphoton ionization (REMPI) has been developed for this purpose and is used to determine the toluene/gasoline concentration in water samples via a headspace measurement. The limit of detection for toluene in water using this probe is 0.54 ppb (wt/wt) with a sample standard deviation of 0.02 ppb (wt/wt). Another technique that has great potential for optical sensing is fluorescence lifetime imaging. A new method for measuring fluorescence lifetime images of quickly decaying species has been developed. This method employs a high powered pulsed laser that excites the fluorescent species in a dual pulse manner, and a non-gated charge coupled device (CCD) for detection of the fluorescence. Unlike other fluorescence lifetime imaging methods, this technique has the potential of monitoring fluorescent species with picosecond lifetimes.
Zhou, Zhenpeng; Li, Tian; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Chengzhi; Li, Na
2014-11-11
Silver-enhanced fluorescence was coupled with a bio-barcode assay to facilitate a dual amplification assay to demonstrate a non-enzymatic approach for simple and sensitive detection of DNA. In the assay design, magnetic nanoparticles seeded with silver nanoparticles were modified with the capture DNA, and silver nanoparticles were modified with the binding of ssDNA and the fluorescently labeled barcode dsDNA. Upon introduction of the target DNA, a sandwich structure was formed because of the hybridization reaction. By simple magnetic separation, silver-enhanced fluorescence of barcode DNAs could be readily measured without the need of a further step to liberate barcode DNAs from silver nanoparticles, endowing the method with simplicity and high sensitivity with a detection limit of 1 pM.
Ma, Jin-Liang; Yin, Bin-Cheng; Le, Huynh-Nhu; Ye, Bang-Ce
2015-06-17
We have developed a label-free method for sequence-specific DNA detection based on surface plasmon enhanced energy transfer (SPEET) process between fluorescent DNA/AgNC string and gold nanoparticles (AuNPs). DNA/AgNC string, prepared by a single-stranded DNA template encoded two emitter-nucleation sequences at its termini and an oligo spacer in the middle, was rationally designed to produce bright fluorescence emission. The proposed method takes advantage of two strategies. The first one is the difference in binding properties of single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA) toward AuNPs. The second one is SPEET process between fluorescent DNA/AgNC string and AuNPs, in which fluorescent DNA/AgNC string can be spontaneously adsorbed onto the surface of AuNPs and correspondingly AuNPs serve as "nanoquencher" to quench the fluorescence of DNA/AgNC string. In the presence of target DNA, the sensing probe hybridized with target DNA to form duplex DNA, leading to a salt-induced AuNP aggregation and subsequently weakened SPEET process between fluorescent DNA/AgNC string and AuNPs. A red-to-blue color change of AuNPs and a concomitant fluorescence increase were clearly observed in the sensing system, which had a concentration dependent manner with specific DNA. The proposed method achieved a detection limit of ∼2.5 nM, offering the following merits of simple design, convenient operation, and low experimental cost because of no chemical modification, organic dye, enzymatic reaction, or separation procedure involved.
de Bruin, Donny; Bossert, Nelli; Aartsma-Rus, Annemieke; Bouwmeester, Dirk
2018-04-06
Short nucleic acid oligomers have found a wide range of applications in experimental physics, biology and medicine, and show potential for the treatment of acquired and genetic diseases. These applications rely heavily on the predictability of hybridization through Watson-Crick base pairing to allow positioning on a nanometer scale, as well as binding to the target transcripts, but also off-target binding to transcripts with partial homology. These effects are of particular importance in the development of therapeutic oligonucleotides, where off-target effects caused by the binding of mismatched sequences need to be avoided. We employ a novel method of probing DNA hybridization using optically active DNA-stabilized silver clusters (Ag-DNA) to measure binding efficiencies through a change in fluorescence intensity. In this way we can determine their location-specific sensitivity to individual mismatches in the sequence. The results reveal a strong dependence of the hybridization on the location of the mismatch, whereby mismatches close to the edges and center show a relatively minor impact. In parallel, we propose a simple model for calculating the annealing ratios of mismatched DNA sequences, which supports our experimental results. The primary result shown in this work is a demonstration of a novel technique to measure DNA hybridization using fluorescent Ag-DNA. With this technique, we investigated the effect of mismatches on the hybridization efficiency, and found a significant dependence on the location of individual mismatches. These effects are strongly influenced by the length of the used oligonucleotides. The novel probe method based on fluorescent Ag-DNA functions as a reliable tool in measuring this behavior. As a secondary result, we formulated a simple model that is consistent with the experimental data.
Modulation of the endogenous production of protoporphyrin IX in a yeast-based model organism
NASA Astrophysics Data System (ADS)
Joniová, Jaroslava; Gerelli, Emmanuel; Wagnières, Georges
2017-02-01
The main aim of this study was to assess conditions at which simple yeast-based model organism produces maximal levels of protoporphyrin IX (PpIX) after an exogenous administration of its precursor, 5-aminolevulinic acid (ALA), and the ferrous-ion chelator 2,2'-bipyridyl. We observed that the fluorescing porphyrin, produced after these administrations, was likely to be PpIX since fluorescence spectroscopy of the porphyrins produced endogenously in yeast cells resembles that of PpIX in DMSO and in vivo in the chick's chorioallantoic membrane model. Also, fluorescence lifetimes of these porphyrins are very similar to that of PpIX in vitro and in vivo. This suggests that PpIX is the main fluorescent compound produced by yeast in our conditions. We found that the conditions at which yeast produces the maximal PpIX were a synchronous administration of 5 μM ALA and 1 mM 2,2'-bipyridyl for yeast incubated in aqueous glucose and 1 mM 2,2'-bipyridyl in the presence of YPD medium. Such a simple model is of high interest to study basic mechanisms involved in the mitochondrial respiration since PpIX, which is produced in this organelle, can be used as an oxygen sensor, or to perform photodynamic therapy and photodiagnosis. Since the absorption and scattering coefficients of this model are much smaller than those of soft tissues over the visible part of the spectrum, a version of this model loaded with appropriated amounts of light absorbing and scattering particles could be designed as a phantom to mimic tumors containing PpIX, a useful tool to optimize certain cancer photodetection set-ups.
Advanced fluorescence imaging endoscopy using an acousto-optic tuneable filter
NASA Astrophysics Data System (ADS)
Whelan, Maurice P.; Bouhifd, Mounir; Aprahamian, Marc
2004-07-01
Two novel prototype instruments for in vivo fluorescence-based medical diagnostics are described. The devices are based on an acousto-optic tuneable filter (AOTF) and can be easily attached to the eyepiece of most commercially available endoscopes. The instruments developed offer significant advantages over typical fixed-filter or filter-wheel fluorescence imaging systems in terms of flexibility, performance and diagnostic potential. Any filtering center-wavelength in the range from 450 to 700 nm can be rapidly selected either by random access or sequential tuning using simple commands delivered over a PC serial interface. In addition, both filtered and unfiltered light can be imaged to facilitate the direct association of fluorescence signals with specific anatomical sites. To demonstrate the system in vivo, a study of the diagnostic potential of fluorescence imaging for pancreatitis was conducted on rats. The aim was to detect extremely low-levels of endogenous protoporphyrin IX (PpIX) that has been shown to accumulate in early-stage diseased tissue undergoing an inflammatory response. Results show clearly that the device is effective in diagnosing mild pancreatitis in rats without the necessity of administering PpIX promoting agents such as ALA. Planning of human clinical trials is currently underway to demonstrate its potential as a tool for non-invasive early diagnosis of gastroenterological diseases.
Fluorescent and colorimetric ion probes based on conjugated oligopyrroles.
Ding, Yubin; Tang, Yunyu; Zhu, Weihong; Xie, Yongshu
2015-03-07
Metal ions and anions play important roles in many industrial and biochemical processes, and thus it is highly desired to detect them in the relevant systems. Small organic molecule based sensors for selective and sensitive detection of target ions show the advantages of low cost, high sensitivity and convenient implementation. In this area, pyrrole has incomparable advantages. It can be easily incorporated into linear and macrocyclic conjugated structures such as dipyrrins, porphyrins, and N-confused porphyrins, which may utilize the imino N and amino NH moieties for binding metal ions and anions, respectively. In this tutorial review, we focus on representative examples to describe the design, syntheses, sensing mechanisms, and applications of the conjugated oligopyrroles. These compounds could be used as colorimetric or fluorescent ion probes, with the advantages of vivid colour and fluorescence changes, easy structural modification and functionalization, and tunable emission wavelengths. Compared with normal porphyrins, simple di- and tripyrrins, as well as some porphyrinoids are more suitable for designing fluorescence "turn-on" metal probes, because they may exhibit flexible confirmations, and metal coordination will improve the rigidity, resulting in vivid fluorescence enhancement. It is noteworthy that the oligopyrrolic moieties may simultaneously act as the binding unit as well as the reporting moiety, which simplifies the design and syntheses of the probes.
Fluorescence detection of dental calculus
NASA Astrophysics Data System (ADS)
Gonchukov, S.; Biryukova, T.; Sukhinina, A.; Vdovin, Yu
2010-11-01
This work is devoted to the optimization of fluorescence dental calculus diagnostics in optical spectrum. The optimal wavelengths for fluorescence excitation and registration are determined. Two spectral ranges 620 - 645 nm and 340 - 370 nm are the most convenient for supra- and subgingival calculus determination. The simple implementation of differential method free from the necessity of spectrometer using was investigated. Calculus detection reliability in the case of simple implementation is higher than in the case of spectra analysis at optimal wavelengths. The use of modulated excitation light and narrowband detection of informative signal allows us to decrease essentially its diagnostic intensity even in comparison with intensity of the low level laser dental therapy.
Quantum Dots in a Polymer Composite: A Convenient Particle-in-a-Box Laboratory Experiment
ERIC Educational Resources Information Center
Rice, Charles V.; Giffin, Guinevere A.
2008-01-01
Semiconductor quantum dots are at the forefront of materials science chemistry with applications in biological imaging and photovoltaic technologies. We have developed a simple laboratory experiment to measure the quantum-dot size from fluorescence spectra. A major roadblock of quantum-dot based exercises is the particle synthesis and handling;…
Raghavender Goud, D; Purohit, Ajay Kumar; Tak, Vijay; Dubey, Devendra Kumar; Kumar, Pravin; Pardasani, Deepak
2014-10-21
A new chemodosimetric protocol based on a tandem S-alkylation followed by desulfurisation reaction of rhodamine-thioamide with mustard gas is reported. The chemodosimeter is highly selective for potential DNA alkylating agents like sulfur mustard, over other simple alkyl halides with the limit of detection of 4.75 μM.
In situ ZnO-PVA nanocomposite coated microfluidic chips for biosensing
NASA Astrophysics Data System (ADS)
Habouti, Salah; Kunstmann-Olsen, Casper; Hoyland, James D.; Rubahn, Horst-Günter; Es-Souni, Mohammed
2014-05-01
Microfluidic chips with integrated fluid and optical connectors have been generated via a simple PDMS master-mould technique. In situ coating using a Zinc oxide polyvinylalcohol based sol-gel method results in ultrathin nanocomposite layers on the fluid channels, which makes them strongly hydrophilic and minimizes auto contamination of the chips by injected fluorescent biomarkers.
Zager, Valerija; Cemazar, Maja; Hreljac, Irena; Lah, Tamara T; Sersa, Gregor; Filipic, Metka
2010-03-01
Human exposure to genotoxic agents in the environment and everyday life represents a serious health threat. Fast and reliable assessment of genotoxicity of chemicals is of main importance in the fields of new chemicals and drug development as well as in environmental monitoring. The tumor suppressor gene p21, the major downstream target gene of activated p53 which is responsible for cell cycle arrest following DNA damage, has been shown to be specifically up-regulated by genotoxic carcinogens. The aim of our study was to develop a human cell-based biosensor system for simple and fast detection of genotoxic agents. Metabolically active HepG2 human hepatoma cells were transfected with plasmid encoding Enhanced Green Fluorescent Protein (EGFP) under the control of the p21 promoter (p21HepG2GFP). DNA damage was induced by genotoxic agents with known mechanisms of action. The increase in fluorescence intensity, due to p21 mediated EGFP expression, was measured with a fluorescence microplate reader. The viability of treated cells was determined by the colorimetric MTS assay. The directly acting alkylating agent methylmethane sulphonate (MMS) showed significant increase in EGFP production after 48 h at 20 μg/mL. The indirectly acting carcinogen benzo(a)pyren (BaP) and the cross-linking agent cisplatin (CisPt) induced a dose- dependent increase in EGFP fluorescence, which was already significant at concentrations 0.13 μg/mL and 0.41 μg/mL, respectively. Vinblastine (VLB), a spindle poison that does not induce direct DNA damage, induced only a small increase in EGFP fluorescence intensity after 24 h at the lowest concentration (0.1 μg/mL), while exposure to higher concentrations was associated with significantly reduced cell viability. The results of our study demonstrated that this novel assay based on the stably transformed cell line p21HepG2GFP can be used as a fast and simple biosensor system for detection of genetic damage caused by chemical agents.
Li, Yaqi; Sun, Li; Qian, Jing; Long, Lingliang; Li, Henan; Liu, Qian; Cai, Jianrong; Wang, Kun
2017-06-15
With the increasing concern of potential health and environmental risk, it is essential to develop reliable methods for transgenic soybean detection. Herein, a simple, sensitive and selective assay was constructed based on homogeneous fluorescence resonance energy transfer (FRET) between CdTe quantum dots (QDs) and multiwalled carbon nanotubes@graphene oxide nanoribbons (MWCNTs@GONRs) to form the fluorescent "on-off-on" switching for simultaneous monitoring dual target DNAs of promoter cauliflower mosaic virus 35s (P35s) and terminator nopaline synthase (TNOS) from transgenic soybean. The capture DNAs were immobilized with corresponding QDs to obtain strong fluorescent signals (turning on). The strong π-π stacking interaction between single-stranded DNA (ssDNA) probes and MWCNTs@GONRs led to minimal background fluorescence due to the FRET process (turning off). The targets of P35s and TNOS were recognized by dual fluorescent probes to form double-stranded DNA (dsDNA) through the specific hybridization between target DNAs and ssDNA probes. And the dsDNA were released from the surface of MWCNTs@GONRs, which leaded the dual fluorescent probes to generate the strong fluorescent emissions (turning on). Therefore, this proposed homogeneous assay can be achieved to detect P35s and TNOS simultaneously by monitoring the relevant fluorescent emissions. Moreover, this assay can distinguish complementary and mismatched nucleic acid sequences with high sensitivity. The constructed approach has the potential to be a tool for daily detection of genetically modified organism with the merits of feasibility and reliability. Copyright © 2017 Elsevier B.V. All rights reserved.
Quantification of endocytosis using a folate functionalized silica hollow nanoshell platform
Sandoval, Sergio; Mendez, Natalie; Alfaro, Jesus G.; Yang, Jian; Aschemeyer, Sharraya; Liberman, Alex; Trogler, William C.; Kummel, Andrew C.
2015-01-01
Abstract. A quantification method to measure endocytosis was designed to assess cellular uptake and specificity of a targeting nanoparticle platform. A simple N-hydroxysuccinimide ester conjugation technique to functionalize 100-nm hollow silica nanoshell particles with fluorescent reporter fluorescein isothiocyanate and folate or polyethylene glycol (PEG) was developed. Functionalized nanoshells were characterized using scanning electron microscopy and transmission electron microscopy and the maximum amount of folate functionalized on nanoshell surfaces was quantified with UV-Vis spectroscopy. The extent of endocytosis by HeLa cervical cancer cells and human foreskin fibroblast (HFF-1) cells was investigated in vitro using fluorescence and confocal microscopy. A simple fluorescence ratio analysis was developed to quantify endocytosis versus surface adhesion. Nanoshells functionalized with folate showed enhanced endocytosis by cancer cells when compared to PEG functionalized nanoshells. Fluorescence ratio analyses showed that 95% of folate functionalized silica nanoshells which adhered to cancer cells were endocytosed, while only 27% of PEG functionalized nanoshells adhered to the cell surface and underwent endocytosis when functionalized with 200 and 900 μg, respectively. Additionally, the endocytosis of folate functionalized nanoshells proved to be cancer cell selective while sparing normal cells. The developed fluorescence ratio analysis is a simple and rapid verification/validation method to quantify cellular uptake between datasets by using an internal control for normalization. PMID:26315280
Pollet, Jeroen; Versteeg, Leroy; Rezende, Wanderson; Strych, Ulrich; Gusovsky, Fabian; Hotez, Peter J; Bottazzi, Maria Elena
2017-03-07
Despite the generally accepted immunostimulatory effect of Toll-Like Receptor 4 (TLR4) agonists and their value as vaccine adjuvants, there remains a demand for fast and easy quantification assays for these TLR4 agonists in order to accelerate and improve vaccine formulation studies. A new medium-throughput method was developed for the quantification of the TLR4 agonist, E6020, independent of the formulation composition. The assay uses a fluorescent hydrazide (DCCH) to label the synthetic lipopolysaccharide (LPS) analog E6020 through its diketone groups. This novel, low-cost, and fluorescence based assay may obviate the need for traditional approaches that primarily rely on Fourier transform infrared spectroscopy (FTIR) or mass spectrometry. The experiments were performed in a wide diversity of vaccine formulations containing E6020 to assess method robustness and accuracy. The assay was also expanded to evaluate the loading efficiency of E6020 in poly(lactic-co-glycolic acid) (PLGA) micro-particles. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ding, Xiaojie; Qu, Lingbo; Yang, Ran; Zhou, Yuchen; Li, Jianjun
2015-06-01
Cysteamine (CA)-capped CdTe quantum dots (QDs) (CA-CdTe QDs) were prepared by the reflux method and utilized as an efficient nano-sized fluorescent sensor to detect mercury (II) ions (Hg(2+) ). Under optimum conditions, the fluorescence quenching effect of CA-CdTe QDs was linear at Hg(2+) concentrations in the range of 6.0-450 nmol/L. The detection limit was calculated to be 4.0 nmol/L according to the 3σ IUPAC criteria. The influence of 10-fold Pb(2+) , Cu(2+) and Ag(+) on the determination of Hg(2+) was < 7% (superior to other reports based on crude QDs). Furthermore, the detection sensitivity and selectivity were much improved relative to a sensor based on the CA-CdTe QDs probe, which was prepared using a one-pot synthetic method. This CA-CdTe QDs sensor system represents a new feasibility to improve the detection performance of a QDs sensor by changing the synthesis method. Copyright © 2014 John Wiley & Sons, Ltd.
Fluorescence-based visualization of autophagic activity predicts mouse embryo viability
NASA Astrophysics Data System (ADS)
Tsukamoto, Satoshi; Hara, Taichi; Yamamoto, Atsushi; Kito, Seiji; Minami, Naojiro; Kubota, Toshiro; Sato, Ken; Kokubo, Toshiaki
2014-03-01
Embryo quality is a critical parameter in assisted reproductive technologies. Although embryo quality can be evaluated morphologically, embryo morphology does not correlate perfectly with embryo viability. To improve this, it is important to understand which molecular mechanisms are involved in embryo quality control. Autophagy is an evolutionarily conserved catabolic process in which cytoplasmic materials sequestered by autophagosomes are degraded in lysosomes. We previously demonstrated that autophagy is highly activated after fertilization and is essential for further embryonic development. Here, we developed a simple fluorescence-based method for visualizing autophagic activity in live mouse embryos. Our method is based on imaging of the fluorescence intensity of GFP-LC3, a versatile marker for autophagy, which is microinjected into the embryos. Using this method, we show that embryonic autophagic activity declines with advancing maternal age, probably due to a decline in the activity of lysosomal hydrolases. We also demonstrate that embryonic autophagic activity is associated with the developmental viability of the embryo. Our results suggest that embryonic autophagic activity can be utilized as a novel indicator of embryo quality.
Darain, Farzana; Gan, Kai Ling; Tjin, Swee Chuan
2009-06-01
A simple microfluidic immunoassay card was developed based on polystyrene (PS) substrate for the detection of horse IgG, an inexpensive model analyte using fluorescence microscope. The primary antibody was captured onto the PS based on covalent bonding via a self-assembled monolayer (SAM) of thiol to pattern the surface chemistry on a gold-coated PS. The immunosensor chip layers were fabricated from sheets by CO(2) laser ablation. The functionalized PS surfaces after each step were characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). After the antibody-antigen interaction as a sandwich immunoassay with a fluorescein isothiocyanate (FITC)-conjugated secondary antibody, the intensity of fluorescence was measured on-chip to determine the concentration of the target analyte. The present immunosensor chip showed a linear response range for horse IgG between 1 microg/ml and 80 microg/ml (r = 0.971, n = 3). The detection limit was found to be 0.71 microg/ml. The developed microfluidic system can be extended for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.
Versatile logic devices based on programmable DNA-regulated silver-nanocluster signal transducers.
Huang, Zhenzhen; Tao, Yu; Pu, Fang; Ren, Jinsong; Qu, Xiaogang
2012-05-21
A DNA-encoding strategy is reported for the programmable regulation of the fluorescence properties of silver nanoclusters (AgNCs). By taking advantage of the DNA-encoding strategy, aqueous AgNCs were used as signal transducers to convert DNA inputs into fluorescence outputs for the construction of various DNA-based logic gates (AND, OR, INHIBIT, XOR, NOR, XNOR, NAND, and a sequential logic gate). Moreover, a biomolecular keypad that was capable of constructing crossword puzzles was also fabricated. These AgNC-based logic systems showed several advantages, including a simple transducer-introduction strategy, universal design, and biocompatible operation. In addition, this proof of concept opens the door to a new generation of signal transducer materials and provides a general route to versatile biomolecular logic devices for practical applications. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Caries Detection Methods Based on Changes in Optical Properties between Healthy and Carious Tissue
Karlsson, Lena
2010-01-01
A conservative, noninvasive or minimally invasive approach to clinical management of dental caries requires diagnostic techniques capable of detecting and quantifying lesions at an early stage, when progression can be arrested or reversed. Objective evidence of initiation of the disease can be detected in the form of distinct changes in the optical properties of the affected tooth structure. Caries detection methods based on changes in a specific optical property are collectively referred to as optically based methods. This paper presents a simple overview of the feasibility of three such technologies for quantitative or semiquantitative assessment of caries lesions. Two of the techniques are well-established: quantitative light-induced fluorescence, which is used primarily in caries research, and laser-induced fluorescence, a commercially available method used in clinical dental practice. The third technique, based on near-infrared transillumination of dental enamel is in the developmental stages. PMID:20454579
Fluorescence based Aptasensors for the determination of hepatitis B virus e antigen.
Huang, Rongrong; Xi, Zhijiang; Deng, Yan; He, Nongyue
2016-08-08
This research is aimed at selecting specific aptamer of hepatitis B e antigen by SELEX and its applications. Hepatitis B e antigen (HBeAg) seroconversion is used as an indicator of virological response when treating patients suffering from chronic hepatitis B. HBeAg also indicates a high viremia and high infectivity in untreated patients. With HBeAg modified magnetic beads as targets, three groups of aptamers are successfully selected. These are the first reported DNA aptamers that can specifically bind to HBeAg. Based on the property that the conformation changes upon binding to its target, aptamer has emerged as ideal candidate in a variety of sensing applications. In this study, we present a simple strategy for aptamer-based fluorescence biosensors for the quantitative detection of HBeAg, in which a fluorescence labeled HBeAg aptamer serves as the molecular recognition element and a short DNA molecule that is complementary to the aptamer serves as the competitor. The LOD for HBeAg is 609 ng/mL. Later, the fluorescence system is deployed in HBeAg positive and negative blood serum (p < 0.05). The total detection assay could be completed in 2 min. These newly isolated aptamers could assist the diagnosis of chronic hepatitis B.
Fluorescence based Aptasensors for the determination of hepatitis B virus e antigen
Huang, Rongrong; Xi, Zhijiang; Deng, Yan; He, Nongyue
2016-01-01
This research is aimed at selecting specific aptamer of hepatitis B e antigen by SELEX and its applications. Hepatitis B e antigen (HBeAg) seroconversion is used as an indicator of virological response when treating patients suffering from chronic hepatitis B. HBeAg also indicates a high viremia and high infectivity in untreated patients. With HBeAg modified magnetic beads as targets, three groups of aptamers are successfully selected. These are the first reported DNA aptamers that can specifically bind to HBeAg. Based on the property that the conformation changes upon binding to its target, aptamer has emerged as ideal candidate in a variety of sensing applications. In this study, we present a simple strategy for aptamer-based fluorescence biosensors for the quantitative detection of HBeAg, in which a fluorescence labeled HBeAg aptamer serves as the molecular recognition element and a short DNA molecule that is complementary to the aptamer serves as the competitor. The LOD for HBeAg is 609 ng/mL. Later, the fluorescence system is deployed in HBeAg positive and negative blood serum (p < 0.05). The total detection assay could be completed in 2 min. These newly isolated aptamers could assist the diagnosis of chronic hepatitis B. PMID:27499342
Wen, Xiaoye; Fan, Zhefeng
2016-11-16
A simple Schiff-base derivative with salicylaldehyde moieties as fluorescent probe 1 was reported by aggregation-induced emission (AIE) characterization for the detection of metal ions. Spectral analysis revealed that probe 1 was highly selective and sensitive to Al 3+ . The probe 1 was also subject to minimal interference from other common competitive metal ions. The detection limit of Al 3+ was 0.4 μM, which is considerably lower than the World Health Organization standard (7.41 μM), and the acceptable level of Al 3+ (1.85 μM) in drinking water. The Job's plot and the results of 1 H-NMR and FT-IR analyses indicated that the binding stoichiometry ratio of probe 1 to Al 3+ was 1:2. Probe 1 demonstrated a fluorescence-enhanced response upon binding with Al 3+ based on AIE characterization. This response was due to the restricted molecular rotation and increased rigidity of the molecular assembly. Probe 1 exhibited good biocompatibility, and Al 3+ was detected in live cells. Therefore, probe 1 is a promising fluorescence probe for Al 3+ detection in the environment. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluating and operationalizing an environmental auditing program: a pilot study.
Gordon, Laura; Bruce, Natalie; Suh, Kathryn N; Roth, Virginia
2014-07-01
Environmental auditing is an important tool to ensure consistent and effective cleaning. Our pilot study compared an alcohol-based fluorescent marking product and an adenosine-5'-triphosphate bioluminescence product for use in an environmental auditing program to determine which product was more practical and acceptable to users. Both products were tested on 15 preselected high touch objects in randomly selected patient rooms, following regular daily cleaning. A room was considered a "pass" if ≥80% of surfaces were adequately cleaned as defined by manufacturers' guidelines. A qualitative survey assessed user preference and operational considerations. Using fluorescent marking, 9 of 37 patient rooms evaluated (24%) were considered a "pass" after daily cleaning. Using adenosine-5'-triphosphate bioluminescence, 21 of 37 patient rooms passed (57%). There was great variability in results between different high touch objects. Eighty percent of users preferred the alcohol-based fluorescent marking product because it provided an effective visual aid to coach staff on proper cleaning techniques and allowed simple and consistent application. Environmental auditing using translucent, alcohol-based fluorescent marking best met the requirements of our organization. Our results reinforce the importance of involving a multidisciplinary team in evaluating and operationalizing an environmental auditing program. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Wang, Yan; Zhang, Zhifang; Zhang, Ya; Yu, Cong
2018-06-01
We have established a real-time and label-free fluorescence turn-on strategy for protease activity detection and inhibitor screening via peptide-induced aggregation-caused quenching of a perylene probe. Because of electrostatic interactions and high hydrophilicity, poly-l-glutamic acid sodium salt (PGA; a negatively charged peptide) could induce aggregation of a positively charged perylene probe (probe 1) and the monomer fluorescence of probe 1 was effectively quenched. After a protease was added, PGA was enzymatically hydrolyzed into small fragments and probe 1 disaggregated. The fluorescence recovery of probe 1 was found to be proportional to the concentration of protease in the range from 0 to 1 mU/ml. The detection limit was down to 0.1 mU/ml. In the presence of a protease inhibitor, protease activity was inhibited and fluorescence recovery reduced. Moreover, we demonstrated the potential application of our method in a complex mixture sample including 1% human serum. Our method is simple, fast and cost effective. Copyright © 2018 John Wiley & Sons, Ltd.
Instrumentation and methodology for quantifying GFP fluorescence in intact plant organs
NASA Technical Reports Server (NTRS)
Millwood, R. J.; Halfhill, M. D.; Harkins, D.; Russotti, R.; Stewart, C. N. Jr
2003-01-01
The General Fluorescence Plant Meter (GFP-Meter) is a portable spectrofluorometer that utilizes a fiber-optic cable and a leaf clip to gather spectrofluorescence data. In contrast to traditional analytical systems, this instrument allows for the rapid detection and fluorescence measurement of proteins under field conditions with no damage to plant tissue. Here we discuss the methodology of gathering and standardizing spectrofluorescence data from tobacco and canola plants expressing GFP. Furthermore, we demonstrate the accuracy and effectiveness of the GFP-Meter. We first compared GFP fluorescence measurements taken by the GFP-Meter to those taken by a standard laboratory-based spectrofluorometer, the FluoroMax-2. Spectrofluorescence measurements were taken from the same location on intact leaves. When these measurements were tested by simple linear regression analysis, we found that there was a positive functional relationship between instruments. Finally, to exhibit that the GFP-Meter recorded accurate measurements over a span of time, we completed a time-course analysis of GFP fluorescence measurements. We found that only initial measurements were accurate; however, subsequent measurements could be used for qualitative purposes.
Optical biosensor system with integrated microfluidic sample preparation and TIRF based detection
NASA Astrophysics Data System (ADS)
Gilli, Eduard; Scheicher, Sylvia R.; Suppan, Michael; Pichler, Heinz; Rumpler, Markus; Satzinger, Valentin; Palfinger, Christian; Reil, Frank; Hajnsek, Martin; Köstler, Stefan
2013-05-01
There is a steadily growing demand for miniaturized bioanalytical devices allowing for on-site or point-of-care detection of biomolecules or pathogens in applications like diagnostics, food testing, or environmental monitoring. These, so called labs-on-a-chip or micro-total analysis systems (μ-TAS) should ideally enable convenient sample-in - result-out type operation. Therefore, the entire process from sample preparation, metering, reagent incubation, etc. to detection should be performed on a single disposable device (on-chip). In the early days such devices were mainly fabricated using glass or silicon substrates and adapting established fabrication technologies from the electronics and semiconductor industry. More recently, the development focuses on the use of thermoplastic polymers as they allow for low-cost high volume fabrication of disposables. One of the most promising materials for the development of plastic based lab-on-achip systems are cyclic olefin polymers and copolymers (COP/COC) due to their excellent optical properties (high transparency and low autofluorescence) and ease of processing. We present a bioanalytical system for whole blood samples comprising a disposable plastic chip based on TIRF (total internal reflection fluorescence) optical detection. The chips were fabricated by compression moulding of COP and microfluidic channels were structured by hot embossing. These microfluidic structures integrate several sample pretreatment steps. These are the separation of erythrocytes, metering of sample volume using passive valves, and reagent incubation for competitive bioassays. The surface of the following optical detection zone is functionalized with specific capture probes in an array format. The plastic chips comprise dedicated structures for simple and effective coupling of excitation light from low-cost laser diodes. This enables TIRF excitation of fluorescently labeled probes selectively bound to detection spots at the microchannel surface. The fluorescence of these detection arrays is imaged using a simple set-up based on a digital consumer camera. Image processing for spot detection and intensity calculation is accomplished using customized software. Using this combined TIRF excitation and imaging based detection approach allowes for effective suppression of background fluorescence from the sample, multiplexed detection in an array format, as well as internal calibration and background correction.
NASA Astrophysics Data System (ADS)
Lysenko, S. A.
2018-01-01
A method for rapid calculation of a flux of stimulated fluorescence of a multilayer optically dense medium with inhomogeneous distribution of the fluorophore has been developed. The light field in the medium at the excitation wavelength of fluorescence is represented by a superposition of incident collimated, incident diffuse, and reflected diffuse fluxes. A two-stream approximation is used to describe the light field in the medium at the wavelength of emission of the fluorescence. Fluxes in adjacent elementary layers of the medium and on its surface are connected by simple matrix operators that are obtained using a combination of engineering approaches of radiation-transfer theory and single-scattering approximation. The calculations of fluorescence fluxes of a four-layer biotissue that are excited and recorded at 400-800 nm are compared with their Monte Carlo simulation with a discrepancy of 1%. The effect of the propagation medium on the fluorescence spectra of 5-ALA-induced protoporphyrin IX that are recorded from human skin was studied, and a technique for their correction that is based on measurements and quantitative analysis of the diffuse reflectance spectrum of skin was proposed.
Direct fluorescence anisotropy assay for cocaine using tetramethylrhodamine-labeled aptamer.
Liu, Yingxiong; Zhao, Qiang
2017-06-01
Development of simple, sensitive, and rapid method for cocaine detection is important in medicine and drug abuse monitoring. Taking advantage of fluorescence anisotropy and aptamer, this study reports a direct fluorescence anisotropy (FA) assay for cocaine by employing an aptamer probe with tetramethylrhodamine (TMR) labeled on a specific position. The binding of cocaine and the aptamer causes a structure change of the TMR-labeled aptamer, leading to changes of the interaction between labeled TMR and adjacent G bases in aptamer sequence, so FA of TMR varies with increasing of cocaine. After screening different labeling positions of the aptamer, including thymine (T) bases and terminals of the aptamer, we obtained a favorable aptamer probe with TMR labeled on the 25th base T in the sequence, which exhibited sensitive and significant FA-decreasing responses upon cocaine. Under optimized assay conditions, this TMR-labeled aptamer allowed for direct FA detection of cocaine as low as 5 μM. The maximum FA change reached about 0.086. This FA method also enabled the detection of cocaine spiked in diluted serum and urine samples, showing potential for applications. Graphical Abstract The binding of cocaine to the TMR-labeled aptamer causes conformation change and alteration of the intramolecular interaction between TMR and bases of aptamer, leading to variance of fluorescence anisotropy (FA) of TMR, so direct FA analyis of cocaine is achieved.
Fluorescence Diffusion in the Presence of Optically Clear Tissues in a Mouse Head Model.
Ancora, Daniele; Zacharopoulos, Athanasios; Ripoll, Jorge; Zacharakis, Giannis
2017-05-01
Diffuse Optical Tomography commonly neglects or assumes as insignificant the presence of optically clear regions in biological tissues, estimating their contribution as a small perturbation to light transport. The inaccuracy introduced by this practice is examined in detail in the context of a complete, based on realistic geometry, virtual fluorescence Diffuse Optical Tomography experiment where a mouse head is imaged in the presence of cerebral spinal fluid. Despite the small thickness of such layer, we point out that an error is introduced when neglecting it from the model with possibly reduction in the accuracy of the reconstruction and localization of the fluorescence distribution within the brain. The results obtained in the extensive study presented here suggest that fluorescence diffuse neuroimaging studies can be improved in terms of quantitative and qualitative reconstruction by accurately taking into account optically transparent regions especially in the cases where the reconstruction is aided by the prior knowledge of the structural geometry of the specimen. Thus, this has only recently become an affordable choice, thanks to novel computation paradigms that allow to run Monte Carlo photon propagation on a simple graphic card, hence speeding up the process a thousand folds compared to CPU-based solutions.
NASA Astrophysics Data System (ADS)
Tan, Hongliang; Li, Qian; Ma, Chanjiao; Song, Yonghai; Xu, Fugang; Chen, Shouhui; Wang, Li
2014-01-01
It is highly desirable to develop a simple and sensitive analytical method for detection of anthrax biomarker (dipicolinic acid, DPA) because of its dangerous nature. In this work, we developed a fluorescent sensor for DPA detection based on terbium ion-functionalized silver nanoparticles with an average size of 6.7 nm (AgNPs-Tb3+). The fluorescent intensity of Tb-DPA complex on the surface of AgNPs was two times higher than that of Tb-DPA complex alone in a solution phase due to the metal-enhanced fluorescence (MEF) effect of AgNPs. The proposed fluorescent sensor exhibits excellent selectivity and high sensitivity for DPA. Importantly, a test paper for DPA detection was fabricated for the first time by the integration of AgNPs-Tb3+ onto the nitrocellulose membrane. Owing to the MEF effect of AgNPs, the lowest detectable concentration of the test paper-integrated AgNPs-Tb3+ for DPA by naked eyes is 10 times lower than that of the test paper-integrated Tb3+ alone. We believe that the presented strategy may open up new avenues to the development of portable and robust-sensing platforms based on functional hybrid materials.
Gaikwad, Ravi M; Dokukin, Maxim E; Iyer, K Swaminathan; Woodworth, Craig D; Volkov, Dmytro O; Sokolov, Igor
2011-04-07
Here we describe a non-traditional method to identify cancerous human cervical epithelial cells in a culture dish based on physical adhesion between silica beads and cells. It is a simple optical fluorescence-based technique which detects the relative difference in the amount of fluorescent silica beads physically adherent to surfaces of cancerous and normal cervical cells. The method utilizes the centripetal force gradient that occurs in a rotating culture dish. Due to the variation in the balance between adhesion and centripetal forces, cancerous and normal cells demonstrate clearly distinctive distributions of the fluorescent particles adherent to the cell surface over the culture dish. The method demonstrates higher adhesion of silica particles to normal cells compared to cancerous cells. The difference in adhesion was initially observed by atomic force microscopy (AFM). The AFM data were used to design the parameters of the rotational dish experiment. The optical method that we describe is much faster and technically simpler than AFM. This work provides proof of the concept that physical interactions can be used to accurately discriminate normal and cancer cells. © The Royal Society of Chemistry 2011
A nanocluster-based fluorescent sensor for sensitive hemoglobin detection.
Yang, Dongqin; Meng, Huijie; Tu, Yifeng; Yan, Jilin
2017-08-01
In this report, a fluorescence sensor for sensitive detection of hemoglobin was developed. Gold nanoclusters were first synthesized with bovine serum albumin. It was found that both hydrogen peroxide and hemoglobin could weakly quench the fluorescence from the gold nanoclusters, but when these two were applied onto the nanolcusters simultaneously, a much improved quenching was resulted. This enhancing effect was proved to come from the catalytic generation of hydroxyl radical by hemoglobin. Under an optimized condition, the quenching linearly related to the concentration of hemoglobin in the range of 1-250nM, and a limit of detection as low as 0.36nM could be obtained. This provided a sensitive means for the quantification of Hb. The sensor was then successfully applied for blood analyses with simple sample pretreatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Fluorescent chemosensor for pyridine based on N-doped carbon dots.
Campos, B B; Abellán, C; Zougagh, M; Jimenez-Jimenez, J; Rodríguez-Castellón, E; Esteves da Silva, J C G; Ríos, A; Algarra, M
2015-11-15
Fluorescent carbon dots (CDs) and its nitrogen doped (N-CDs) nanoparticles have been synthesized from lactose as precursor using a bottom-up hydrothermal methodology. The synthesized nanoparticles have been characterized by elemental analysis, FTIR, Raman, TEM, DLS, XPS, and steady-state and life-time fluorescence. The synthesized carbon nanoparticles, CDs and N-CDs, have a size at about 7.7±2.4 and 50±15nm, respectively, and quantum yields of 8% (CDs) and 11% (N-CDs). These techniques demonstrated the effectiveness of the synthesis procedure and the functionalization of the CDs surface with amine and amide groups in the presence of NH3 in aqueous media. The effect of excitation wavelength and pH on the luminescent properties was studied. Under the optimal conditions, the nitrogen doped nanoparticles can be used as pyridine sensor in aqueous media because they show an enhancement of its fluorescence with a good linear relationship. The analytical method is simple, reproducible and very sensitive for pyridine determination. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe
2018-03-01
Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation.
Upconversion fluorescent strip sensor for rapid determination of Vibrio anguillarum
NASA Astrophysics Data System (ADS)
Zhao, Peng; Wu, Yuanyuan; Zhu, Yihua; Yang, Xiaoling; Jiang, Xin; Xiao, Jingfan; Zhang, Yuanxing; Li, Chunzhong
2014-03-01
Here, we report a simple and ultrasensitive upconversion fluorescent strip sensor based on NaYF4:Yb,Er nanoparticles (NPs) and the lateral flow immunochromatographic assay (LFIA). Carboxyl-modified β-NaYF4:Yb,Er NPs were successfully synthesized by a facile one-pot solvothermal approach, upon further coupling with monoclonal antibody, the resultant UCNPs-antibody conjugates probes were used in LFIA and served as signal vehicles for the fluorescent reporters. V. anguillarum was used as a model analyte to demonstrate the use of this strip sensor. The limit of the detection for the fluorescent strip was determined as 102 CFU mL-1, which is 100 times lower than those displayed by enzyme-linked immunosorbent assays, while the time needed for the detection was only 15 min. Furthermore, no cross-reaction with other eight pathogens was found, indicating the good specificity of the strip. This developed LFIA would offer the potential as a useful tool for the quantification of pathogens analysis in the future.
Temperature Response of Rhodamine B-Doped Latex Particles. From Solution to Single Particles.
Soleilhac, Antonin; Girod, Marion; Dugourd, Philippe; Burdin, Béatrice; Parvole, Julien; Dugas, Pierre-Yves; Bayard, François; Lacôte, Emmanuel; Bourgeat-Lami, Elodie; Antoine, Rodolphe
2016-04-26
Nanoparticle-based temperature imaging is an emerging field of advanced applications. Herein, the sensitivity of the fluorescence of rhodamine B-doped latex nanoparticles toward temperature is described. Submicrometer size latex particles were prepared by a surfactant-free emulsion polymerization method that allowed a simple and inexpensive way to incorporate rhodamine B into the nanoparticles. Also, rhodamine B-coated latex nanoparticles dispersed in water were prepared in order to address the effect of the dye location in the nanoparticles on their temperature dependence. A better linearity of the temperature dependence emission of the rhodamine B-embedded latex particles, as compared to that of free rhodamine B dyes or rhodamine B-coated latex particles, is observed. Temperature-dependent fluorescence measurements by fluorescent confocal microscopy on individual rhodamine B-embedded latex particles were found similar to those obtained for fluorescent latex nanoparticles in solution, indicating that these nanoparticles could be good candidates to probe thermal processes as nanothermometers.
Simple device for the direct visualization of oral-cavity tissue fluorescence
NASA Astrophysics Data System (ADS)
Lane, Pierre M.; Gilhuly, Terence; Whitehead, Peter D.; Zeng, Haishan; Poh, Catherine; Ng, Samson; Williams, Michelle; Zhang, Lewei; Rosin, Miriam; MacAulay, Calum E.
2006-03-01
Early identification of high-risk disease could greatly reduce both mortality and morbidity due to oral cancer. We describe a simple handheld device that facilitates the direct visualization of oral-cavity fluorescence for the detection of high-risk precancerous and early cancerous lesions. Blue excitation light (400 to 460 nm) is employed to excite green-red fluorescence from fluorophores in the oral tissues. Tissue fluorescence is viewed directly along an optical axis collinear with the axis of excitation to reduce inter- and intraoperator variability. This robust, field-of-view device enables the direct visualization of fluorescence in the context of surrounding normal tissue. Results from a pilot study of 44 patients are presented. Using histology as the gold standard, the device achieves a sensitivity of 98% and specificity of 100% when discriminating normal mucosa from severe dysplasia/carcinoma in situ (CIS) or invasive carcinoma. We envisage this device as a suitable adjunct for oral cancer screening, biopsy guidance, and margin delineation.
Wang, Fangfang; Huang, Lingyun; Na, Na; He, Dacheng; Sun, Dezhi; Ouyang, Jin
2012-05-21
In this paper, a simple and sensitive small-molecule fluorescent probe, 2,5-dihydroxy-4'-dimethylaminochalcone (DHDMAC), was designed and synthesized for the detection of human serum proteins via hydrophobic interactions after polyacrylamide gel electrophoresis (PAGE). This probe produced lower fluorescence emission in the absence of proteins, and the emission intensity was significantly increased after the interaction with serum proteins. To demonstrate the imaging performance of this probe as a fluorescent dye, a series of experiments was conducted that included sensitivity comparison and 2D-PAGE. The results indicated that the sensitivity of DHDMAC staining is comparable to that of the most widely used fluorescent dye, SYPRO Ruby, and more protein spots (including thyroxine-binding globulin, angiotensinogen, afamin, zinc-α-2-glycoprotein and α-1-antichymotrypsin) were detected after 2D-PAGE. Therefore, DHDMAC is a good protein reporter due to its fast staining procedure, low detection limits and high resolution.
Carbon dots based fluorescent sensor for sensitive determination of hydroquinone.
Ni, Pengjuan; Dai, Haichao; Li, Zhen; Sun, Yujing; Hu, Jingting; Jiang, Shu; Wang, Yilin; Li, Zhuang
2015-11-01
In this paper, a novel biosensor based on Carbon dots (C-dots) for sensitive detection of hydroquinone (H2Q) is reported. It is interesting to find that the fluorescence of the C-dots could be quenched by H2Q directly. The possible quenching mechanism is proposed, which shows that the quenching effect may be caused by the electron transfer from C-dots to oxidized H2Q-quinone. Based on the above principle, a novel C-dots based fluorescent probe has been successfully applied to detect H2Q. Under the optimal condition, detection limit down to 0.1 μM is obtained, which is far below U.S. Environmental Protection Agency estimated wastewater discharge limit of 0.5 mg/L. Moreover, the proposed method shows high selectivity for H2Q over a number of potential interfering species. Finally, several water samples spiked with H2Q are analyzed utilizing the sensing method with satisfactory recovery. The proposed method is simple with high sensitivity and excellent selectivity, which provides a new approach for the detection of various analytes that can be transformed into quinone. Copyright © 2015 Elsevier B.V. All rights reserved.
Yin, Huan-Shun; Li, Bing-Chen; Zhou, Yun-Lei; Wang, Hai-Yan; Wang, Ming-Hui; Ai, Shi-Yun
2017-10-15
MicroRNAs have been involved into many biological processes and are regarded as disease biomarkers. Simple, rapid, sensitive and selective method for microRNA detection is crucial for early diagnosis and therapy of diseases. In this work, sensitive fluorescence assay was developed for microRNA-21 detection based on DNA polymerase induced strand displacement amplification reaction, Mg 2+ -dependent DNAzyme catalysis reaction, and magnetic separation. In the presence of target microRNA-21, amounts of trigger DNA could be produced with DNA polymerase induced strand displacement amplification reaction, and the trigger DNA could be further hybridized with signal DNA, which was labeled with biotin and AMCA dye. After introduction of Mg 2+ , trigger DNA could form DNAzyme to cleave signal DNA. After magnetic separation, the DNA fragment with AMCA dye could give fluorescence signal, which was related to microRNA-21 concentration. Based on the two efficient signal amplifications, the developed method showed high detection sensitivity with low detection limit of 0.27fM (3σ). In addition, this fluorescence strategy also possessed excellent detection specificity, and could be applied to analyze microRNA-21 expression level in serum of cancer patient. According to the obtained results, the developed fluorescence method might be a promising detection platform for microRNA-21 quantitative analysis in biomedical research and clinical diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Jin, Meng; Mou, Zhao-Li; Zhang, Rui-Ling; Liang, Si-Si; Zhang, Zhi-Qi
2017-05-15
The development of a simple and accurate quantitative method for the determination of 6-mercaptopurine (6-MP) is of great importance because of its serious side effects. Ratiometric fluorescence (RF) sensors are not subject to interference from environmental factors, and exhibit enhanced precision and accuracy. Therefore, a novel RF sensor for the selective detection of 6-MP was developed based on a dual-emission nanosensor. The nanosensor was fabricated by combining a blue-emission metal-organic framework (MOF) NH 2 -MIL-53(Al) (λ em =425nm) with green-emission 3-mercaptopropionic acid-capped CdTe quantum dots (MPA-CdTe QDs) (λ em =528nm) under a single excitation wavelength (335nm). Upon addition of 6-MP, the fluorescence of NH 2 -MIL-53(Al) in the nanohybrid was selectively quenched due to strong inner filter effects, while the fluorescence of the MPA-CdTe QDs was enhanced. The novel RF sensor exhibited higher selectivity towards 6-MP than CdTe QDs alone, and higher sensitivity than MOFs alone. 6-MP could be detected in the range of 0-50μM with a detection limit of 0.15μM (S/N=3). The developed sensor was applied for the determination of 6-MP in human urine samples and satisfactory results were obtained. Overall, a novel and efficient fluorescence-based method was developed for the detection of 6-MP in biosamples. Copyright © 2016 Elsevier B.V. All rights reserved.
Courtney, Jane; Woods, Elena; Scholz, Dimitri; Hall, William W; Gautier, Virginie W
2015-01-01
We introduce here MATtrack, an open source MATLAB-based computational platform developed to process multi-Tiff files produced by a photo-conversion time lapse protocol for live cell fluorescent microscopy. MATtrack automatically performs a series of steps required for image processing, including extraction and import of numerical values from Multi-Tiff files, red/green image classification using gating parameters, noise filtering, background extraction, contrast stretching and temporal smoothing. MATtrack also integrates a series of algorithms for quantitative image analysis enabling the construction of mean and standard deviation images, clustering and classification of subcellular regions and injection point approximation. In addition, MATtrack features a simple user interface, which enables monitoring of Fluorescent Signal Intensity in multiple Regions of Interest, over time. The latter encapsulates a region growing method to automatically delineate the contours of Regions of Interest selected by the user, and performs background and regional Average Fluorescence Tracking, and automatic plotting. Finally, MATtrack computes convenient visualization and exploration tools including a migration map, which provides an overview of the protein intracellular trajectories and accumulation areas. In conclusion, MATtrack is an open source MATLAB-based software package tailored to facilitate the analysis and visualization of large data files derived from real-time live cell fluorescent microscopy using photoconvertible proteins. It is flexible, user friendly, compatible with Windows, Mac, and Linux, and a wide range of data acquisition software. MATtrack is freely available for download at eleceng.dit.ie/courtney/MATtrack.zip.
Courtney, Jane; Woods, Elena; Scholz, Dimitri; Hall, William W.; Gautier, Virginie W.
2015-01-01
We introduce here MATtrack, an open source MATLAB-based computational platform developed to process multi-Tiff files produced by a photo-conversion time lapse protocol for live cell fluorescent microscopy. MATtrack automatically performs a series of steps required for image processing, including extraction and import of numerical values from Multi-Tiff files, red/green image classification using gating parameters, noise filtering, background extraction, contrast stretching and temporal smoothing. MATtrack also integrates a series of algorithms for quantitative image analysis enabling the construction of mean and standard deviation images, clustering and classification of subcellular regions and injection point approximation. In addition, MATtrack features a simple user interface, which enables monitoring of Fluorescent Signal Intensity in multiple Regions of Interest, over time. The latter encapsulates a region growing method to automatically delineate the contours of Regions of Interest selected by the user, and performs background and regional Average Fluorescence Tracking, and automatic plotting. Finally, MATtrack computes convenient visualization and exploration tools including a migration map, which provides an overview of the protein intracellular trajectories and accumulation areas. In conclusion, MATtrack is an open source MATLAB-based software package tailored to facilitate the analysis and visualization of large data files derived from real-time live cell fluorescent microscopy using photoconvertible proteins. It is flexible, user friendly, compatible with Windows, Mac, and Linux, and a wide range of data acquisition software. MATtrack is freely available for download at eleceng.dit.ie/courtney/MATtrack.zip. PMID:26485569
Selective detection of pyrophosphate anion by a simple Cd(II) based terpyridine complex
NASA Astrophysics Data System (ADS)
Purohit, Aditya Kumar; Ghosh, Biswa Nath; Kar, Pravin Kumar
2018-01-01
A simple ratiometric terpyridine-Cd(ll) complex was synthesized by the treatment of CdCl2 with terpyridine ligand 4‧-(4-N,N‧-dimethylaminophenyl)-2,2‧:6‧,2″-terpyridine. The synthesized complex was found to act as a selective fluorescent chemosensor for pyrophosphate P2O74 - (PPi) over other anions like F-, Cl-, Br-, CO32 -, SO32 -, AcO-, NO2-, and H2PO4-. Furthermore, the receptor probe was also successfully employed in HeLa cell for PPi detection, which indicates this can be used as a chemosensor for cells.
Identification of plant compounds that inactivate Shiga toxin from Escherichia coli O157:H7
USDA-ARS?s Scientific Manuscript database
In the present study, we describe a simple cell-based assay for the detection of Stxs and inhibitors of Stx activity. A Vero cell line that expresses a destabilized variant (t1/2 = 2 hours) of the enhanced green fluorescent protein (d2EGFP) was used to monitor the Stx-induced inhibition of protein ...
Demonstration of a single-wavelength spectral-imaging-based Thai jasmine rice identification
NASA Astrophysics Data System (ADS)
Suwansukho, Kajpanya; Sumriddetchkajorn, Sarun; Buranasiri, Prathan
2011-07-01
A single-wavelength spectral-imaging-based Thai jasmine rice breed identification is demonstrated. Our nondestructive identification approach relies on a combination of fluorescent imaging and simple image processing techniques. Especially, we apply simple image thresholding, blob filtering, and image subtracting processes to either a 545 or a 575nm image in order to identify our desired Thai jasmine rice breed from others. Other key advantages include no waste product and fast identification time. In our demonstration, UVC light is used as our exciting light, a liquid crystal tunable optical filter is used as our wavelength seclector, and a digital camera with 640activepixels×480activepixels is used to capture the desired spectral image. Eight Thai rice breeds having similar size and shape are tested. Our experimental proof of concept shows that by suitably applying image thresholding, blob filtering, and image subtracting processes to the selected fluorescent image, the Thai jasmine rice breed can be identified with measured false acceptance rates of <22.9% and <25.7% for spectral images at 545 and 575nm wavelengths, respectively. A measured fast identification time is 25ms, showing high potential for real-time applications.
Pan, Hong; Wang, Sufan; Dao, Xiaoyao; Ni, Yonghong
2018-02-05
Tb 3+ -doped zinc-based coordination polymer nanospindle bundles (Zn-PDC/Tb 3+ , or [Zn(2,5-PDC)(H 2 O) 2 ]·H 2 O/Tb 3+ ) were synthesized by a simple solution precipitation route at room temperature, employing Zn(NO 3 ) 2 , Tb(NO 3 ) 3 , and 2,5-Na 2 PDC as the initial reactants, and a mixture of water and ethanol with the volume ratio of 10:10 as the solvent. The as-obtained nanostructures presented strong fluorescent emission under the excitation of 298 nm light, which was attributed to the characteristic emission of the Tb 3+ ion. It was found that the above-mentioned strong fluorescence of the nanostructures could be selectively quenched by cefixime (CFX) in aqueous solution. The other common antibiotics hardly interfered. Thus, as-obtained Zn-PDC/Tb 3+ nanostructures could be prepared as a highly sensitive fluorescence probe for selective detection of CFX in an aqueous system. The corresponding detection limit reached 72 ppb. The theoretic calculation and UV-vis absorption experiments confirmed that the fluorescence quenching of Zn-PDC/Tb 3+ nanostructures toward CFX should be attributed to the electron transfer and the fluorescence inner filter effect between the fluorescent matter and the analyte. In addition, the strong fluorescence of the nanostructures could also be selectively quenched by acetone in the water system.
5-ALA/PpIX fluorescence detection of gastrointestinal neoplasia
NASA Astrophysics Data System (ADS)
Borisova, Ekaterina G.; Vladimirov, Borislav; Terziev, Ivan; Ivanova, Radina; Avramov, Latchezar
2009-07-01
In the recent study delta-ALA/PpIX is used as fluorescent marker for dysplasia and tumor detection in esophagus, stomach and colon. ALA is administered per os six to eight (depending on the lesion location) hours before measurements at dose 20mg/kg weight. High-power light-emitting diode at 405 nm is used as an excitation source. Special opto-mechanical device is built for the LED to use the light guide of standard video-endoscopic system. Through endoscopic instrumental channel a fiber is applied to return information about fluorescence to microspectrometer. The fluorescence detected from tumor sites has very complex spectral origins. It consists of autofluorescence, fluorescence from exogenous fluorophores and re-absorption from the chromophores accumulated in the tissue investigated. Spectral features observed during endoscopic investigations could be distinct as the next regions: 450-630 nm region, where tissue autofluorescence is observed; 630-710 nm region, where fluorescence of PpIX is clearly pronounced; 530-580 nm region, where minima in the autofluorescence signal are observed, related to re-absorption of oxy-hemoglobin in this spectral area. Endogenous and exogenous fluorescence spectra are used to develop simple but effective algorithm, based on dimensionless ratio of the signals at 560 and 635 nm, for differentiation of normal/abnormal gastrointestinal tissues. Very good correlation between fluorescence signals and histology examination of the lesions investigated is achieved.
Dong, Jiande; Liu, Meiying; Jiang, Ruming; Huang, Hongye; Wan, Qing; Wen, Yuanqing; Tian, Jianwen; Dai, Yanfeng; Zhang, Xiaoyong; Wei, Yen
2018-05-17
Fluorescent probes have long been regarded as tools for imaging living organisms with advantages such as high sensitivity, good designability and multifunctional potential. Many fluorescent probes, especially the probes based on aggregation-induced emission (AIE) dyes, have received increasing attention since the AIE phenomenon was discovered. These AIE dye-based fluorescent probes could elegantly overcome the notorious quenching effect caused by aggregation of conventional organic dyes. However, it is still difficult to directly apply these AIE-active dyes for biomedical applications owing to their hydrophobic nature. Therefore, the development of novel and facile strategies to endow them with water dispersibility is of critical importance. In this work, we exploit an efficient and simple strategy to fabricate an AIE dye-based fluorescent copolymer through the combination of reversible addition-fragmentation chain transfer and the Biginelli reaction. Moreover, the copolymer can self-assemble to fluorescent polymeric nanoparticles (FPNs) in water solution. Hydrophilic poly(PEGMA-co-AEMA) was reacted with the AIE-active dye 4',4‴-(1,2-diphenylethene-1,2-diyl)bis([1,1'-biphenyl]-4-carbaldehyde (CHO-TPE-CHO) to form amphiphilic luminescent polymers using urea as the connection bridge. The successful synthesis of the final products (poly(PEGMA-co-AEMA-TPE) FPNs) was confirmed by various instruments. Furthermore, Transmission electron microscopy (TEM) images manifest that poly(PEGMA-co-AEMA-TPE) copolymers will self-assemble into spherical nanoparticles in aqueous environments with sizes between 100 nm and 200 nm. The cell uptake and bioimaging experiment confirm that poly(PEGMA-co-AEMA-TPE) FPNs have excellent biocompatibility and emit strong green fluorescence in a cellular environment. Thus, poly(PEGMA-co-AEMA-TPE) FPNs are excellent candidates for biomedical applications. Copyright © 2018. Published by Elsevier Inc.
The development of a MIP-optosensor for the detection of monoamine naphthalenes in drinking water.
Valero-Navarro, Angel; Salinas-Castillo, Alfonso; Fernández-Sánchez, Jorge F; Segura-Carretero, Antonio; Mallavia, Ricardo; Fernández-Gutiérrez, Alberto
2009-03-15
To enhance the advantages of fluorescent flow-through sensing for drinking water we have designed a novel sensing matrix based on molecularly imprinted polymers (MIPs). The synergic combination of a tailor-made MIP recognition with a selective room temperature fluorescence detection is a novel concept for optosensing devices and is assessed here for the simple and selective determination of pollutants in water. We describe a simple approach to preparing synthetic receptors for monoamine naphthalene compounds (MA-NCs) using non-covalent molecular imprinting techniques and naphthalene as template. We examine in detail the binding characteristics of the imprinted polymer and describe the flow-through sensor of MA-NCs by solid-surface fluorescence. Its detection limits for recognizing 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA) separately are 26 ngmL(-1) and 50 ngmL(-1), respectively, and it also determines 1-NA and 2-NA simultaneously with a detection limit of 45 ngmL(-1). All the instrumental, chemical and flow variables were carefully optimized and an interference study was carried out to demonstrate its applicability and selectivity. Finally, we applied it to the analysis of 1-NA and 2-NA in tap and mineral waters, obtaining a 98% average recovery rate.
A simple dental caries detection system using full spectrum of laser-induced fluorescence
NASA Astrophysics Data System (ADS)
Rocha-Cabral, Renata Maciel; Mendes, Fausto Medeiros; Maldonado, Edison Puig; Zezell, Denise Maria
2015-06-01
Objectives: to develop an apparatus for the detection of early caries lesions in enamel using the full extent of the tooth fluorescence spectrum, through the integration of a laser diode, fiber optics, filters and one portable spectrometer connected to a computer, all commercially available; to evaluate the developed device in clinical and laboratory tests, and compare its performance with commercial equipment. Methods: clinical examinations were performed in patients with indication for exodontics of premolars. After examinations, the patients underwent surgery and the teeth were stored individually. The optical measurements were repeated approximately two months after extraction, on the same sites previously examined, then histological analysis was carried out. Results: the spectral detector has presented high specificity and moderate sensitivity when applied to differentiate between healthy and damaged tissues, with no significant differences from the performance of the commercial equipment. The developed device is able to detect initial damages in enamel, with depth of approximately 300 μm. Conclusions: we successfully demonstrated the development of a simple and portable system based in laser-induced fluorescence for caries detection, assembled from common commercial parts. As the spectral detector acquires a complete recording of the spectrum from each tissue, it is possible to use it for monitoring developments of caries lesions.
Widely accessible method for superresolution fluorescence imaging of living systems
Dedecker, Peter; Mo, Gary C. H.; Dertinger, Thomas; Zhang, Jin
2012-01-01
Superresolution fluorescence microscopy overcomes the diffraction resolution barrier and allows the molecular intricacies of life to be revealed with greatly enhanced detail. However, many current superresolution techniques still face limitations and their implementation is typically associated with a steep learning curve. Patterned illumination-based superresolution techniques [e.g., stimulated emission depletion (STED), reversible optically-linear fluorescence transitions (RESOLFT), and saturated structured illumination microscopy (SSIM)] require specialized equipment, whereas single-molecule–based approaches [e.g., stochastic optical reconstruction microscopy (STORM), photo-activation localization microscopy (PALM), and fluorescence-PALM (F-PALM)] involve repetitive single-molecule localization, which requires its own set of expertise and is also temporally demanding. Here we present a superresolution fluorescence imaging method, photochromic stochastic optical fluctuation imaging (pcSOFI). In this method, irradiating a reversibly photoswitching fluorescent protein at an appropriate wavelength produces robust single-molecule intensity fluctuations, from which a superresolution picture can be extracted by a statistical analysis of the fluctuations in each pixel as a function of time, as previously demonstrated in SOFI. This method, which uses off-the-shelf equipment, genetically encodable labels, and simple and rapid data acquisition, is capable of providing two- to threefold-enhanced spatial resolution, significant background rejection, markedly improved contrast, and favorable temporal resolution in living cells. Furthermore, both 3D and multicolor imaging are readily achievable. Because of its ease of use and high performance, we anticipate that pcSOFI will prove an attractive approach for superresolution imaging. PMID:22711840
Yang, Jie; Hu, Wei; Li, Huirong; Hou, Hanna; Tu, Yi; Liu, Bo
2018-04-18
Two-photon microscopy imaging has been widely applied in biological imaging, but the development of two-photon absorption probes is obviously lagging behind in the development of imaging technology. In this paper, a two-photon fluorescent probe (1) based on pyrimidine 2-isothiocyanate has been designed and synthesized through a simple method for two-photon biological imaging. Probe 1 was able to couple effectively with the amino groups on biomolecules. To verify the reactivity of the isothiocyanate group on probe 1 and the amine groups on the biomolecules, d-glucosamine was chosen as a model biomolecule to conjugate with probe 1. The result showed that probe 1 could effectively conjugate with d-glucosamine to synthesize probe 2, and the yield of probe 2 was 83%. After conjugating with d-glucosamine, linear absorption spectra, single-photon fluorescence spectra, and two-photon fluorescence spectra of probes 1 and 2 did not present significant changes. Probes 1 and 2 exhibited high fluorescence quantum yields (0.71-0.79) in toluene and chloroform. They also exhibited different photo-physical properties in solvents with different polarities. The two-photon absorption cross-section of probe 1 was 953 GM in toluene. In addition, probe 1 could be effectively conjugated with transferrin, and the conjugated probe (Tf-1) could be transported into Hep G2 cells through a receptor-mediated process for biological imaging. These results demonstrate that such probes are expected to have great potential applications in two-photon fluorescence bioimaging.
Chair-side detection of Prevotella Intermedia in mature dental plaque by its fluorescence.
Nomura, Yoshiaki; Takeuchi, Hiroaki; Okamoto, Masaaki; Sogabe, Kaoru; Okada, Ayako; Hanada, Nobuhiro
2017-06-01
Prevotella intermedia/nigrescens is one of the well-known pathogens causing periodontal diseases, and the red florescence excited by the visible blue light caused by the protoporphyrin IX in the bacterial cells could be useful for the chair-side detection. The aim of this study was to evaluated levels of periodontal pathogen, especially P. intermedia in clinical samples of red fluorescent dental plaque. Thirty two supra gingival plaque samples from six individuals were measured its fluorescence at 640nm wavelength excited by 409nm. Periodontopathic bacteria were counted by the Invader PLUS PCR assay. Co-relations the fluorescence intensity and bacterial counts were analyzed by Person's correlation coefficient and simple and multiple regression analysis. Positive and negative predictive values of the fluorescence intensities for with or without P. intermedia in supragingival plaque was calculated. When relative fluorescence unit (RFU) were logarithmic transformed, statistically significant linear relations between RFU and bacterial counts were obtained for P. intermedia, Porphyromonas gingivalis and Tannerella forsythia. By the multiple regression analysis, only P. intermedia had statistically significant co-relation with fluorescence intensities. All of the fluorescent dental plaque contained P. intermedia m. In contrast, 28% of non-fluorescent plaques contained P. intermedia. To check the fluorescence dental plaque in the oral cavity could be the simple chair-side screening of the mature dental plaque before examining the periodontal pathogens especially P. intermedia by the PCR method. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moester, Martiene J.C.; Schoeman, Monique A.E.; Oudshoorn, Ineke B.
2014-01-03
Highlights: •We validate a simple and fast method of quantification of in vitro mineralization. •Fluorescently labeled agents can detect calcium deposits in the mineralized matrix of cell cultures. •Fluorescent signals of the probes correlated with Alizarin Red S staining. -- Abstract: Alizarin Red S staining is the standard method to indicate and quantify matrix mineralization during differentiation of osteoblast cultures. KS483 cells are multipotent mouse mesenchymal progenitor cells that can differentiate into chondrocytes, adipocytes and osteoblasts and are a well-characterized model for the study of bone formation. Matrix mineralization is the last step of differentiation of bone cells and ismore » therefore a very important outcome measure in bone research. Fluorescently labelled calcium chelating agents, e.g. BoneTag and OsteoSense, are currently used for in vivo imaging of bone. The aim of the present study was to validate these probes for fast and simple detection and quantification of in vitro matrix mineralization by KS483 cells and thus enabling high-throughput screening experiments. KS483 cells were cultured under osteogenic conditions in the presence of compounds that either stimulate or inhibit osteoblast differentiation and thereby matrix mineralization. After 21 days of differentiation, fluorescence of stained cultures was quantified with a near-infrared imager and compared to Alizarin Red S quantification. Fluorescence of both probes closely correlated to Alizarin Red S staining in both inhibiting and stimulating conditions. In addition, both compounds displayed specificity for mineralized nodules. We therefore conclude that this method of quantification of bone mineralization using fluorescent compounds is a good alternative for the Alizarin Red S staining.« less
Photonic crystal enhanced fluorescence immunoassay on diatom biosilica.
Squire, Kenneth; Kong, Xianming; LeDuff, Paul; Rorrer, Gregory L; Wang, Alan X
2018-05-16
Fluorescence biosensing is one of the most established biosensing methods, particularly fluorescence spectroscopy and microscopy. These are two highly sensitive techniques but require high grade electronics and optics to achieve the desired sensitivity. Efforts have been made to implement these methods using consumer grade electronics and simple optical setups for applications such as point-of-care diagnostics, but the sensitivity inherently suffers. Sensing substrates, capable of enhancing fluorescence are thus needed to achieve high sensitivity for such applications. In this paper, we demonstrate a photonic crystal-enhanced fluorescence immunoassay biosensor using diatom biosilica, which consists of silica frustules with sub-100 nm periodic pores. Utilizing the enhanced local optical field, the Purcell effect and increased surface area from the diatom photonic crystals, we create ultrasensitive immunoassay biosensors that can significantly enhance fluorescence spectroscopy as well as fluorescence imaging. Using standard antibody-antigen-labeled antibody immunoassay protocol, we experimentally achieved 100× and 10× better detection limit with fluorescence spectroscopy and fluorescence imaging respectively. The limit of detection of the mouse IgG goes down to 10 -16 M (14 fg/mL) and 10 -15 M (140 fg/mL) for the two respective detection modalities, virtually sensing a single mouse IgG molecule on each diatom frustule. The effectively enhanced fluorescence imaging in conjunction with the simple hot-spot counting analysis method used in this paper proves the great potential of diatom fluorescence immunoassay for point-of-care biosensing. Scanning electron microscope image of biosilica diatom frustule that enables significant enhancement of fluorescence spectroscopy and fluorescence image. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Jiao, Zinuo; Zhang, Yu; Xu, Wei; Zhang, Xiangtao; Jiang, Haibo; Wu, Pengcheng; Fu, Yanyan; He, Qingguo; Cao, Huimin; Cheng, Jiangong
2017-05-26
A multiple-anchored fluorescent probe ((((hexane-1,6-diylbis(2,7-bis(4-formyl)-phenyl)-9H-fluorine-9,9-diyl))-bis(hexane-6,1-diyl))-bis(9H-carbazole-9,3,6-triyl))-tetrakis(benzene-4,1-diyl))-tetraformyl-(8FP-2F) with eight aldehyde groups was designed and synthesized. The molecule has four branches and highly twisted structure. Furthermore, it tends to self-assemble into nanospheres, which is beneficial for gaseous analyte penetration and high fluorescence quantum efficiency. Among gaseous analytes, detection of aniline vapor is extraordinarily important in the control of environmental issues and human diseases. Herein, 8FP-2F was introduced to detect aniline vapor with distinguished sensitivity and selectivity via simple Schiff base reaction at room temperature. After exposure to saturate aniline vapor, the 89% fluorescence of 8FP-2F was quenched in 50 s and the detection limit was as low as 3 ppb. Further study showed the suitable HOMO/LUMO energy levels and matched orbital symmetry between probe and aniline molecules ensured chemical reaction and PET process work together. The synergistic effect resulted in a significant sensing performance and fluorescence quenching toward aniline vapor. Moreover, the multiple active sites structure of 8FP-2F means it could be applied for constructing many interesting structures and highly efficient organic optoelectronic functional materials.
Lei, Rong; Jiang, Hongshan; Hu, Fan; Yan, Jin; Zhu, Shuifang
2017-02-01
Leaf chlorosis induced by plant virus infection has a short fluorescence lifetime, which reflects damaged photosynthetic complexes and degraded chloroplasts. Plant viruses often induce chlorosis and necrosis, which are intimately related to photosynthetic functions. Chlorophyll fluorescence lifetime measurement is a valuable noninvasive tool for analyzing photosynthetic processes and is a sensitive indicator of the environment surrounding the fluorescent molecules. In this study, our central goal was to explore the effect of viral infection on photosynthesis by employing chlorophyll fluorescence lifetime imaging (FLIM), steady-state fluorescence, non-photochemical quenching (NPQ), transmission electron microscopy (TEM), and pigment analysis. The data indicated that the chlorophyll fluorescence lifetime of chlorotic leaves was significantly shorter than that of healthy control leaves, and the fitted short lifetime component of chlorophyll fluorescence of chlorotic leaves was dominant. This dominant short lifetime component may result from damage to the structure of thylakoid, which was confirmed by TEM. The NPQ value of chlorotic leaves was slightly higher than that of healthy green leaves, which can be explained by increased neoxanthin, lutein and violaxanthin content relative to chlorophyll a. The difference in NPQ is slight, but FLIM can provide simple and direct characterization of PSII structure and photosynthetic function. Therefore, this technique shows great potential as a simple and rapid method for studying mechanisms of plant virus infection.
Highly stable lipid-encapsulation of fluorescent nanodiamonds for bioimaging applications.
Sotoma, Shingo; Hsieh, Feng-Jen; Chen, Yen-Wei; Tsai, Pei-Chang; Chang, Huan-Cheng
2018-01-23
Highly stable lipid-encapsulated fluorescent nanodiamonds (FNDs) are produced by photo-crosslinking of diacetylene-containing lipids physically attached to the FND surface. Not only is this coating method simple and fast, but also it gives the FND-lipid hybrids favorable properties for bioapplications. The hybrids are useful as fluorescent biolabels as well as fiducial markers for correlative light and electron microscopy.
Yu, Tingting; Sun, Ping; Hu, Yijie; Ji, Yinggang; Zhou, Hongping; Zhang, Baowei; Tian, Yupeng; Wu, Jieying
2016-12-15
A simple-molecule fluorescence probe L has been designed, synthesized and characterized, which shows high selectivity and sensitivity for the main group magnesium ion through fluorescence "turn-on" response in ethanol solution, and no interference from calcium ion in particular. Detection limit of probe L is 1.47×10(-6) M and the rapid response could reach about 15-20s. The recognition mechanism has been established by fluorescence spectra, (1)H NMR study. Moreover, probe L presents a great photostability, low toxicity and cellular permeability, then we have carried out fluorescent bio-imaging of the probe L for magnesium ions in HeLa cells, which showed that probe L could be utilized to detect the intracellular magnesium ion. Furthermore, it is successfully used as a magnesium ion developer in plant tissues, which shows that it not only can be well tracking the transport of magnesium ion but also make a corresponding fluorescence response to different concentrations magnesium ion. These results would make this probe a great potential application for detecting Mg(2+) in biological system. Copyright © 2016 Elsevier B.V. All rights reserved.
One-pot synthesis of active copper-containing carbon dots with laccase-like activities.
Ren, Xiangling; Liu, Jing; Ren, Jun; Tang, Fangqiong; Meng, Xianwei
2015-12-14
Herein, an effective strategy for designing a new type of nanozyme, blue fluorescent laccase mimics, is reported. Active copper-containing carbon dots (Cu-CDs) were synthesized through a simple, nontoxic and one-pot hydrothermal method, which showed favorable photoluminescence properties and good photostability under high-salt conditions or in a broad pH range (3.0-13.5). The Cu-CDs possessed intrinsic laccase-like activities and could catalyze the oxidation of the laccase substrate p-phenylenediamine (PPD) to produce a typical color change from colorless to brown. Poly(methacrylic acid sodium salt) (PMAA) not only was used as the carbon source and reducing agent, but also provided carboxyl groups to assist flocculation between Cu-CDs and polyacrylamide, which facilitated the removal of PPD. Importantly, the intrinsic fluorescence of the as-prepared Cu-CDs could indicate the presence of hydroquinone, one of the substrates of laccases, based on laccase mimics and fluorescence quenching.
Li, Yan-Yun; Jiang, Xiao-Qin; Lu, Ling-Fei; Zhang, Min; Shi, Guoyue
2016-04-01
In this work, we presented a simple, label-free and rapid-responsive fluorescence assay for iodide (I(-)) detection based on "molecular beacon (MB)"-hosted thioflavin T (ThT), achieving a limit of detection as low as 158 nM. The proposed method exhibited very good selectivity to I(-) ions over other anions interference due to the strong binding force between I(-) ions with Hg(2+). Upon the addition of I(-) ions, it would capture Hg(2+) from a T-Hg(2+)-T complex belonging to the MB-like DNA hairpin structure, which eventually quenched the initial fluorescence as output. In addition, it was successfully applied for operation of an integrated DNA logic gate system and to the determination of I(-) in real samples such as human urine. Copyright © 2016 Elsevier B.V. All rights reserved.
Chang, Lingqian; Chen, Feng; Zhang, Xiaokang; Kuang, Tairong; Li, Mi; Hu, Jiaming; Shi, Junfeng; Lee, Ly James; Cheng, Huanyu; Li, Yiwen
2017-05-17
Extensive efforts have been devoted to the development of surfactant-free electronic ink (E-ink) with excellent display resolution for high-definition resolution display. Herein, we report the use of polydopamine-based synthetic melanin, a class of functional nanoparticles with similar chemical compositions and physical properties to those of naturally occurring melanin, as a new E-ink material. It was found that such E-ink displays could achieve ultrahigh resolution (>10 000 ppi) and low power consumption (operation voltage of only 1 V) in aqueous solutions. Interestingly, simple oxidation of synthetic melanin nanoparticles enables the generation of intrinsic fluorescence, allowing further development of fluorescent E-ink displays with nanoscale resolution. We describe these bioinspired materials in an initial proof-of-concept study and propose that synthetic melanin nanoparticles will be suitable for electronic nanoinks with a potential wide range of applications in molecular patterning and fluorescence bioimaging.
Wide-field depth-sectioning fluorescence microscopy using projector-generated patterned illumination
NASA Astrophysics Data System (ADS)
Delica, Serafin; Mar Blanca, Carlo
2007-10-01
We present a simple and cost-effective wide-field, depth-sectioning, fluorescence microscope utilizing a commercial multimedia projector to generate excitation patterns on the sample. Highly resolved optical sections of fluorescent pollen grains at 1.9 μm axial resolution are constructed using the structured illumination technique. This requires grid excitation patterns to be scanned across the sample, which is straightforwardly implemented by creating slideshows of gratings at different phases, projecting them onto the sample, and synchronizing camera acquisition with slide transition. In addition to rapid dynamic pattern generation, the projector provides high illumination power and spectral excitation selectivity. We exploit these properties by imaging mouse neural cells in cultures multistained with Alexa 488 and Cy3. The spectral and structural neural information is effectively resolved in three dimensions. The flexibility and commercial availability of this light source is envisioned to open multidimensional imaging to a broader user base.
A Simple, Low-Cost Platform for Real-Time Isothermal Nucleic Acid Amplification
Craw, Pascal; Mackay, Ruth E.; Naveenathayalan, Angel; Hudson, Chris; Branavan, Manoharanehru; Sadiq, S. Tariq; Balachandran, Wamadeva
2015-01-01
Advances in microfluidics and the introduction of isothermal nucleic acid amplification assays have resulted in a range of solutions for nucleic acid amplification tests suited for point of care and field use. However, miniaturisation of instrumentation for such assays has not seen such rapid advances and fluorescence based assays still depend on complex, bulky and expensive optics such as fluorescence microscopes, photomultiplier tubes and sensitive lens assemblies. In this work we demonstrate a robust, low cost platform for isothermal nucleic acid amplification on a microfluidic device. Using easily obtainable materials and commercial off-the-shelf components, we show real time fluorescence detection using a low cost photodiode and operational amplifier without need for lenses. Temperature regulation on the device is achieved using a heater fabricated with standard printed circuit board fabrication methods. These facile construction methods allow fabrications at a cost compatible with widespread deployment to resource poor settings. PMID:26389913
Azmi, Nur Ellina; Ramli, Noor Izaanin; Abdullah, Jaafar; Abdul Hamid, Mohammad Azmi; Sidek, Hamidah; Abd Rahman, Samsulida; Ariffin, Nurhayati; Yusof, Nor Azah
2015-05-15
A novel optical detection system consisting of combination of uricase/HRP-CdS quantum dots (QDs) for the determination of uric acid in urine sample is described. The QDs was used as an indicator to reveal fluorescence property of the system resulting from enzymatic reaction of uricase and HRP (horseradish peroxidase), which is involved in oxidizing uric acid to allaintoin and hydrogen peroxide. The hydrogen peroxide produced was able to quench the QDs fluorescence, which was proportional to uric acid concentration. The system demonstrated sufficient activity of uricase and HRP at a ratio of 5U:5U and pH 7.0. The linearity of the system toward uric acid was in the concentration range of 125-1000 µM with detection limit of 125 µM. Copyright © 2014 Elsevier B.V. All rights reserved.
Plastic lab-on-a-chip for fluorescence excitation with integrated organic semiconductor lasers.
Vannahme, Christoph; Klinkhammer, Sönke; Lemmer, Uli; Mappes, Timo
2011-04-25
Laser light excitation of fluorescent markers offers highly sensitive and specific analysis for bio-medical or chemical analysis. To profit from these advantages for applications in the field or at the point-of-care, a plastic lab-on-a-chip with integrated organic semiconductor lasers is presented here. First order distributed feedback lasers based on the organic semiconductor tris(8-hydroxyquinoline) aluminum (Alq3) doped with the laser dye 4-dicyanomethylene-2-methyl-6-(p-dimethylaminostyril)-4H-pyrane (DCM), deep ultraviolet induced waveguides, and a nanostructured microfluidic channel are integrated into a poly(methyl methacrylate) (PMMA) substrate. A simple and parallel fabrication process is used comprising thermal imprint, DUV exposure, evaporation of the laser material, and sealing by thermal bonding. The excitation of two fluorescent marker model systems including labeled antibodies with light emitted by integrated lasers is demonstrated.
Xiang, Dongshan; Li, Fengquan; Wu, Chenyi; Shi, Boan; Zhai, Kun
2017-11-01
We designed two double quenching molecular beacons (MBs) with simple structure based on guanine (G base) and Black Hole Quencher (BHQ), and developed a new analytical method for sensitive simultaneous detection of two DNAs by synchronous fluorescence analysis. In this analytical method, carboxyl fluorescein (FAM) and tetramethyl-6-carboxyrhodamine (TAMRA) were respectively selected as fluorophore of two MBs, Black Hole Quencher 1 (BHQ-1) and Black Hole Quencher 2 (BHQ-2) were respectively selected as organic quencher, and three continuous nucleotides with G base were connected to organic quencher (BHQ-1 and BHQ-2). In the presence of target DNAs, the two MBs hybridize with the corresponding target DNAs, the fluorophores are separated from organic quenchers and G bases, leading to recovery of fluorescence of FAM and TAMRA. Under a certain conditions, the fluorescence intensities of FAM and TAMRA all exhibited good linear dependence on their concentration of target DNAs (T1 and T2) in the range from 4 × 10 -10 to 4 × 10 -8 molL -1 (M). The detection limit (3σ, n = 13) of T1 was 3 × 10 -10 M and that of T2 was 2×10 -10 M, respectively. Compared with the existing analysis methods for multiplex DNA with MBs, this proposed method based on double quenching MBs is not only low fluorescence background, short analytical time and low detection cost, but also easy synthesis and good stability of MB probes. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Xiaochun; Yu, Shaoming; Yang, Liang; Wang, Jianping; Jiang, Changlong
2016-07-01
The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F- on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F- can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F- in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F- has been successfully developed. The paper sensor showed high sensitivity for aqueous F-, and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes.The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F- on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F- can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F- in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F- has been successfully developed. The paper sensor showed high sensitivity for aqueous F-, and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02878k
Lin, Bixia; Yu, Ying; Cao, Yujuan; Guo, Manli; Zhu, Debin; Dai, Jiaxing; Zheng, Minshi
2018-02-15
The rapid detection of antibiotic residual in everyday life is very important for food safety. In order to realize the on-site and visual detection of antibiotic, a POCT method was established by using digital image colorimetry based on smartphone. Streptomycin was taken as the analyte model of antibiotics, streptomycin aptamer preferentially recognized analyte, and the excess aptamer hybridized with the complementary DNA to form the dsDNA. SYBR Green I combined with the dsDNA and then emitted obvious green fluorescence, thus the fluorescence intensity decreased with the increasing of streptomycin concentration. Then a smartphone-based device was constructed as the fluorescence readout. The smartphone camera acquired the images of the fluorescence derived from the samples, and the Touch Color APP installed in smartphone read out the RGB values of the images. There was a linear relationship between the G values and the streptomycin concentrations in the range of 0.1-100µM. The detection limit was 94nM, which was lower than the maximum residue limit defined by World Health Organization. The POCT method was applied for determining streptomycin in chicken and milk samples with recoveries in 94.1-110%. This method had the advantages of good selectivity, simple operation and on-site visualization. Copyright © 2017 Elsevier B.V. All rights reserved.
Label-Free Carbon-Dots-Based Ratiometric Fluorescence pH Nanoprobes for Intracellular pH Sensing.
Shangguan, Jingfang; He, Dinggeng; He, Xiaoxiao; Wang, Kemin; Xu, Fengzhou; Liu, Jinquan; Tang, Jinlu; Yang, Xue; Huang, Jin
2016-08-02
Measuring pH in living cells is of great importance for better understanding cellular functions as well as providing pivotal assistance for early diagnosis of diseases. In this work, we report the first use of a novel kind of label-free carbon dots for intracellular ratiometric fluorescence pH sensing. By simple one-pot hydrothermal treatment of citric acid and basic fuchsin, the carbon dots showing dual emission bands at 475 and 545 nm under single-wavelength excitation were synthesized. It is demonstrated that the fluorescence intensities of the as-synthesized carbon dots at the two emissions are pH-sensitive simultaneously. The intensity ratio (I475 nm/I545 nm) is linear against pH values from 5.2 to 8.8 in buffer solution, affording the capability as ratiometric probes for intracellular pH sensing. It also displays that the carbon dots show excellent reversibility and photostability in pH measurements. With this nanoprobe, quantitative fluorescence imaging using the ratio of two emissions (I475 nm/I545 nm) for the detection of intracellular pH were successfully applied in HeLa cells. In contrast to most of the reported nanomaterials-based ratiometric pH sensors which rely on the attachment of additional dyes, these carbon-dots-based ratiometric probes are low in toxicity, easy to synthesize, and free from labels.
Jiang, Wei; Wang, Shenliang; Yuen, Lik Hang; Kwon, Hyukin; Ono, Toshikazu
2013-01-01
Contamination of soil and groundwater by petroleum-based products is an extremely widespread and important environmental problem. Here we have tested a simple optical approach for detecting and identifying such industrial contaminants in soil samples, using a set of fluorescent DNA-based chemosensors in pattern-based sensing. We used a set of diverse industrial volatile chemicals to screen and identify a set of five short oligomeric DNA fluorophores on PEG-polystyrene microbeads that could differentiate the entire set after exposure to their vapors in air. We then tested this set of five fluorescent chemosensor compounds for their ability to respond with fluorescence changes when exposed to headgas over soil samples contaminated with one of ten different samples of crude oil, petroleum distillates, fuels, lubricants and additives. Statistical analysis of the quantitative fluorescence change data (as Δ(R,G,B) emission intensities) revealed that these five chemosensors on beads could differentiate all ten product mixtures at 1000 ppm in soil within 30 minutes. Tests of sensitivity with three of the contaminant mixtures showed that they could be detected and differentiated in amounts at least as low as one part per million in soil. The results establish that DNA-polyfluorophores may have practical utility in monitoring the extent and identity of environmental spills and leaks, while they occur and during their remediation. PMID:23878719
Shanmugam, Akshaya; Usmani, Mohammad; Mayberry, Addison; Perkins, David L; Holcomb, Daniel E
2018-01-01
Miniaturized imaging devices have pushed the boundaries of point-of-care imaging, but existing mobile-phone-based imaging systems do not exploit the full potential of smart phones. This work demonstrates the use of simple imaging configurations to deliver superior image quality and the ability to handle a wide range of biological samples. Results presented in this work are from analysis of fluorescent beads under fluorescence imaging, as well as helminth eggs and freshwater mussel larvae under white light imaging. To demonstrate versatility of the systems, real time analysis and post-processing results of the sample count and sample size are presented in both still images and videos of flowing samples.
Early Detection of Breast Cancer Using Molecular Beacons
2008-01-01
a molecular beacon (MB)-based approach for direct examination of gene expression in viable and fixed cells (2, 3). This objective of proposed study ...can be distinguished from normal cells (dark) (Figure 1) (2, 3, 8). Recently, a class of new fluorescent emitting nanoparticles, semiconductor ...morphological classification. This method may offer a simple and fast procedure to detect biomarker gene expression in clinical samples. Our study results
Simple-MSSM: a simple and efficient method for simultaneous multi-site saturation mutagenesis.
Cheng, Feng; Xu, Jian-Miao; Xiang, Chao; Liu, Zhi-Qiang; Zhao, Li-Qing; Zheng, Yu-Guo
2017-04-01
To develop a practically simple and robust multi-site saturation mutagenesis (MSSM) method that enables simultaneously recombination of amino acid positions for focused mutant library generation. A general restriction enzyme-free and ligase-free MSSM method (Simple-MSSM) based on prolonged overlap extension PCR (POE-PCR) and Simple Cloning techniques. As a proof of principle of Simple-MSSM, the gene of eGFP (enhanced green fluorescent protein) was used as a template gene for simultaneous mutagenesis of five codons. Forty-eight randomly selected clones were sequenced. Sequencing revealed that all the 48 clones showed at least one mutant codon (mutation efficiency = 100%), and 46 out of the 48 clones had mutations at all the five codons. The obtained diversities at these five codons are 27, 24, 26, 26 and 22, respectively, which correspond to 84, 75, 81, 81, 69% of the theoretical diversity offered by NNK-degeneration (32 codons; NNK, K = T or G). The enzyme-free Simple-MSSM method can simultaneously and efficiently saturate five codons within one day, and therefore avoid missing interactions between residues in interacting amino acid networks.
One-step synthesis of fluorescent carbon dots for sensitive and selective detection of hyperin.
Liu, Lizhen; Mi, Zhi; Hu, Qin; Li, Caiqing; Li, Xiaohua; Feng, Feng
2018-08-15
In this article, we presented a new rapid, sensitive and selective method for the determination of hyperin (Hyp) based on the fluorescence quenching of fluorescent carbon dots (CDs). The CDs were prepared by simply mixing an aqueous solution of citric acid with diphosphorus pentoxide. This one-step synthetic route is fast and simple with neither high temperature nor complicated synthesis steps is involved. When Hyp was added to CDs solution, the fluorescence intensity of the CDs significantly decreased. The CDs display high selectivity for Hyp over many potentially interfering substances. Under the optimized conditions, a good linear relationship between the fluorescence intensity ratio F o /F and the concentration of Hyp is obtained in a range of 0.22-55 µM with a detection limit (S/N = 3) of 78.3 nM. The method was successfully applied for the determination of Hyp in fufangmuji granules and human serum samples with recoveries in a range of 93.3-107.0%. This paper highlights the usefulness of CDs as an effective fluorescence probe for the Hyp detection due to its easy preparation, low-cost, excellent photostability, favorable biocompatibility and low cytotoxicity. Copyright © 2018 Elsevier B.V. All rights reserved.
[Determination of H2S in Rat Intestinal Perfusion Solution Based on Fluorescence Analysis].
Hou, Jun-feng; Li, Xin-xia; Shen, Xue-ru; Huojia, Miliban; Guan, Ming
2015-08-01
Under alkaline conditions, Fluorescein mercury has strong fluorescence, however, when it met S(2-), its fluorescence would quench, in view of the above, a fluorescence method for determination of H2S in biological samples was established. In the 0.1 mol · L(-1) NaOH dilution, when the concentration of fluorescein Mercury and Na2S was 5.0 × 10(-5) and 1.0 × 10(-5) mol · L(-1) respectively, the fluorescence intensity of system was determined at 522 nm. The results showed that, at the range of 4.0 × 10(-7)~2.0 × 10(-6) mol · L(-1), the concentration decreasing of H2S and fluorescence intensity had good linear relationship, r=0.9980, the RSD of precision test was 4.59% (n=7), the detection limit was 3.5 × 10(-8) mol · L(-1), the content of H2S in the sample were 1.01 × 10(-6) and 1.15 × 10(-6) mol · L(-1), and the recovery rate was 95.8%~101.0%, the method has the advantages of simple operation, high sensitivity, good selectivity, can accurately determine of H2S in intestinal perfused solution, and provides the basis for the determination of endogenous H2S.
Zhang, Wang; Qiu, Ling-Guang; Yuan, Yu-Peng; Xie, An-Jian; Shen, Yu-Hua; Zhu, Jun-Fa
2012-06-30
Covalent organic frameworks (COFs) are a new generation of porous materials constructed from light elements linked by strong covalent bonds. Herein we present rapid preparation of highly fluorescent nanoparticles of a new type of COF, i.e. melamine-based porous polymeric network SNW-1, by a microwave-assisted synthesis route. Although the synthesis of SNW-1 has to be carried out at 180°C for 3d under conventional reflux conditions, SNW-1 nanoparticles could be obtained in 6h by using such a microwave-assisted method. The results obtained have clearly demonstrated that microwave-assisted synthesis is a simple yet highly efficient approach to nanoscale COFs or other porous polymeric materials. Remarkably, the as-synthesized SNW-1 nanoparticles exhibit extremely high sensitivity and selectivity, as well as fast response to nitroaromatic explosives such as 2,4,6-trinitrotoluene (TNT), 2,4,6-trinitrophenylmethylnitramine (Tetryl) and picric acid (PA) without interference by common organic solvents, which is due to the nanoscaled size and unique hierarchical porosity of such fluorescence-based sensing material. Copyright © 2012 Elsevier B.V. All rights reserved.
Non-enzymatic Fluorescent Biosensor for Glucose Sensing Based on ZnO Nanorods
NASA Astrophysics Data System (ADS)
Mai, Hong Hanh; Pham, Van Thanh; Nguyen, Viet Tuyen; Sai, Cong Doanh; Hoang, Chi Hieu; Nguyen, The Binh
2017-06-01
We have developed a non-enzymatic fluorescent biosensor for glucose sensing based on ZnO nanorods. ZnO nanorods of high density, high crystallinity, and good alignment were grown on low-cost industrial copper substrates at low temperature. To grow them directly on the substrates without using a seed layer, we utilized a simple one-step seedless hydrothermal method, which is based on galvanic cell structure. Herein, the glucose-treated ZnO nanorods together with the ultraviolet (UV) irradiation of the sample during the photoluminescent measurement played the role of a catalyst. They decomposed glucose into hydrogen peroxide (H2O2) and gluconic acid, which is similar to the glucose oxidase enzyme (GOx) used in enzymatic sensors. Due to the formation of H2O2, the photoluminescence intensity of the UV emission peak of ZnO nanorods decreased as the glucose concentration increased from 1 mM to 100 mM. In comparison with glucose concentration of a normal human serum, which is in the range of 4.4-6.6 mM, the obtained results show potential of non-enzymatic fluorescent biosensors in medical applications.
Wu, Qiongqiong; Chen, Hongyu; Fang, Aijin; Wu, Xinyang; Liu, Meiling; Li, Haitao; Zhang, Youyu; Yao, Shouzhuo
2017-12-22
Construction of a new multifunctional chemo/biosensing platform for small biomolecules and tumor markers is of great importance in analytical chemistry. Herein, a novel universal multifunctional nanoplatform for biomolecules and enzyme activity detection was proposed based on fluorescence resonance energy transfer (FRET) between upconversion nanoparticles (UCNPs) and target-inducing enlarged gold nanoparticles (AuNPs). The reductive molecule such as H 2 O 2 can act as the reductant to reduce HAuCl 4 , which will make the Au seeds grow. The enlarged AuNPs can effectively quench the fluorescence of UCNPs owing to the good spectral overlap between the absorption band of the AuNPs and the emission band of the UCNPs. Utilizing the FRET between the UCNPs and enlarged AuNPs, good linear relationship between the fluorescence of UCNPs and the concentration of H 2 O 2 can be found. Based on this strategy, H 2 O 2 related molecules such as l-lactate, glucose, and uric acid can also be quantified. On the basis of UCNPs and PVP/HAuCl 4 , a general strategy for other reductants such as ascorbic acid (AA), dopamine (DA), or enzyme activity can be established. Therefore, the universal multifunctional nanoplatform based on UCNPs and the target-inducing in situ enlarged Au NPs will show its potential as a simple method for the detection of some life related reductive molecules, enzyme substrates, as well as enzyme activity.
Open-source do-it-yourself multi-color fluorescence smartphone microscopy
Sung, Yulung; Campa, Fernando; Shih, Wei-Chuan
2017-01-01
Fluorescence microscopy is an important technique for cellular and microbiological investigations. Translating this technique onto a smartphone can enable particularly powerful applications such as on-site analysis, on-demand monitoring, and point-of-care diagnostics. Current fluorescence smartphone microscope setups require precise illumination and imaging alignment which altogether limit its broad adoption. We report a multi-color fluorescence smartphone microscope with a single contact lens-like add-on lens and slide-launched total-internal-reflection guided illumination for three common tasks in investigative fluorescence microscopy: autofluorescence, fluorescent stains, and immunofluorescence. The open-source, simple and cost-effective design has the potential for do-it-yourself fluorescence smartphone microscopy. PMID:29188104
Lühn, Susanne; Grimm, Juliane C; Alban, Susanne
2014-04-10
Sulfated polysaccharides (SP) from algae are of great interest due to their manifold biological activities. Obstacles to commercial (especially medical) application include considerable variability and complex chemical composition making the analysis and the quality control challenging. The aim of this study was to evaluate a simple microplate assay for screening the quality of SP. It is based on the fluorescence intensity (FI) increase of the sensor molecule Polymer-H by SP and was originally developed for direct quantification of SP. Exemplarily, 65 SP batches isolated from the red alga Delesseria sanguinea (D.s.-SP) and several other algae polysaccharides were investigated. Their FI increase in the Polymer-H assay was compared with other analytical parameters. By testing just one concentration of a D.s.-SP sample, quality deviations from the reference D.s.-SP and thus both batch-to-batch variability and stability can be detected. Further, structurally distinct SP showed to differ in their concentration-dependent FI profiles. By using corresponding reference compounds, the Polymer-H assay is therefore applicable as identification assay with high negative predictability. In conclusion, the Polymer-H assay showed to represent not only a simple method for quantification, but also for characterization identification and differentiation of SP of marine origin.
Xu, Yuanhong; Li, Jing; Wang, Erkang
2008-05-01
Based on the dimer-monomer equilibrium movement of the fluorescent dye Pyronin Y (PY), a rapid, simple, highly sensitive, label-free method for protein detection was developed by microchip electrophoresis with LIF detection. PY formed a nonfluorescent dimer induced by the premicellar aggregation of an anionic surfactant, SDS, however, the fluorescence intensity of the system increased dramatically when proteins such as BSA, bovine hemoglobin, cytochrome c, and trypsin were added to the solution due to the transition of dimer to fluorescent monomer. Furthermore, 1-ethyl-3-methylimidazolium tetrafluoroborate (EMImBF4) instead of PBS was applied as running buffers in microchip electrophoresis. Due to the excellent properties of EMImBF4, not only nonspecific protein adsorption was more efficiently suppressed, but also approximately ten-fold higher fluorescence intensity enhancement was obtained than that using PBS. Under the optimal conditions, detection limits for BSA, bovine hemoglobin, cytochrome c, and trypsin were 1.00x10(-6), 2x10(-6), 7x10(-7), and 5x10(-7) mg/mL, respectively. Thus, without covalent modification of the protein, a protein assay method with high sensitivity was achieved on microchips.
Ultrasensitive detection of lead (II) based on fluorescent aptamer-functionalized carbon nanotubes.
Taghdisi, Seyed Mohammad; Emrani, Somayeh Sarreshtehdar; Tabrizian, Kaveh; Ramezani, Mohammad; Abnous, Khalil; Emrani, Ahmad Sarreshtehdar
2014-05-01
Lead contamination is a serious environmental problem with toxic effects in human. Here, we developed a simple and sensitive sensing method employing ATTO 647N/aptamer-SWNT ensemble for detection of Pb(2+). This method is based on the super quenching capability of single-walled carbon nanotubes (SWNTs), high affinity of the aptamer toward Pb(2+) and different propensities of ATTO 647N-aptamer and ATTO 647N-aptamer/Pb(2+) complex for adsorption on SWNTs. In the absence of Pb(2+), the fluorescence of ATTO 647N-aptamer is efficiently quenched by SWNTs. Upon addition of Pb(2+), the aptamer binds to its target, leading to the formation of a G-quadruplex/Pb(2+) complex and does not interact with SWNTs and ATTO 647N-aptamer starts fluorescing. This sensor exhibited a high selectivity toward Pb(2+) and a limit of detection (LOD) as low as 0.42 nM was obtained. Also this sensor could be applied for detection of Pb(2+) ions in tap water and biological sample like serum with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.
Recent developments in optical detection methods for microchip separations.
Götz, Sebastian; Karst, Uwe
2007-01-01
This paper summarizes the features and performances of optical detection systems currently applied in order to monitor separations on microchip devices. Fluorescence detection, which delivers very high sensitivity and selectivity, is still the most widely applied method of detection. Instruments utilizing laser-induced fluorescence (LIF) and lamp-based fluorescence along with recent applications of light-emitting diodes (LED) as excitation sources are also covered in this paper. Since chemiluminescence detection can be achieved using extremely simple devices which no longer require light sources and optical components for focusing and collimation, interesting approaches based on this technique are presented, too. Although UV/vis absorbance is a detection method that is commonly used in standard desktop electrophoresis and liquid chromatography instruments, it has not yet reached the same level of popularity for microchip applications. Current applications of UV/vis absorbance detection to microchip separations and innovative approaches that increase sensitivity are described. This article, which contains 85 references, focuses on developments and applications published within the last three years, points out exciting new approaches, and provides future perspectives on this field.
NASA Astrophysics Data System (ADS)
Li, Yanping; Zhang, Xin; Zhang, Ling; Jiang, Ke; Cui, Yuanjing; Yang, Yu; Qian, Guodong
2017-11-01
Hydrogen sulfide (H2S) has been commonly viewed as a gas signaling molecule in various physiological and pathological processes. However, the highly efficient H2S detection still remains challenging. Herein, we designed a new robust nano metal-organic framework (MOF) UiO-66-CH=CH2 as a fluorescent probe for rapid, sensitive and selective detection of biological H2S. UiO-66-CH=CH2 was prepared by heating ZrCl4 and 2-vinylterephthalic acid via a simple method. UiO-66-CH=CH2 displayed fluorescence quenching to H2S and kept excellent selectivity in the presence of biological relevant analytes especially the cysteine and glutathione. This MOF-based probe also exhibited fast response (10 s) and high sensitivity with a detection limit of 6.46 μM which was within the concentration range of biological H2S in living system. Moreover, this constructed MOF featured water-stability, nanoscale (20-30 nm) and low toxicity, which made it a promising candidate for biological H2S sensing.
A dansyl-rhodamine chemosensor for Fe(III) based on off-on FRET.
Piao, Jingyu; Lv, Jia; Zhou, Xin; Zhao, Tong; Wu, Xue
2014-07-15
A novel fluorescent chemosensor bearing a rhodamine and a dansyl moiety was developed for highly selective detection of Fe(3+) based on fluorescence resonance energy transfer (FRET) mechanism. Binding of Fe(3+) to the chemosensor induced spirolactam ring opening in the rhodamine moiety and subsequent off-on FRET from the dansyl energy donor to the rhodamine energy acceptor due to the spectral overlap between the emission of the dansyl moiety and the absorption of the ring opened rhodamine moiety. Job's plot analysis indicated a 1:1 binding stoichiometry between the chemosensor and Fe(3+). The association constant was estimated to be 2.72×10(3) M(-1) according to the Benesi-Hildebrand method. With the feature of easy synthesis, simple structural skeleton and excellent sensing ability, the newly synthesized chemosensor provided the potential for applying as a highly selective fluorescent probe in complex samples containing various competitive metal ions and developing other metal ion chemosensors to fulfill various needs of biological and environmental field. Copyright © 2014 Elsevier B.V. All rights reserved.
Real-time PCR (qPCR) primer design using free online software.
Thornton, Brenda; Basu, Chhandak
2011-01-01
Real-time PCR (quantitative PCR or qPCR) has become the preferred method for validating results obtained from assays which measure gene expression profiles. The process uses reverse transcription polymerase chain reaction (RT-PCR), coupled with fluorescent chemistry, to measure variations in transcriptome levels between samples. The four most commonly used fluorescent chemistries are SYBR® Green dyes and TaqMan®, Molecular Beacon or Scorpion probes. SYBR® Green is very simple to use and cost efficient. As SYBR® Green dye binds to any double-stranded DNA product, its success depends greatly on proper primer design. Many types of online primer design software are available, which can be used free of charge to design desirable SYBR® Green-based qPCR primers. This laboratory exercise is intended for those who have a fundamental background in PCR. It addresses the basic fluorescent chemistries of real-time PCR, the basic rules and pitfalls of primer design, and provides a step-by-step protocol for designing SYBR® Green-based primers with free, online software. Copyright © 2010 Wiley Periodicals, Inc.
Near-isotropic 3D optical nanoscopy with photon-limited chromophores
Tang, Jianyong; Akerboom, Jasper; Vaziri, Alipasha; Looger, Loren L.; Shank, Charles V.
2010-01-01
Imaging approaches based on single molecule localization break the diffraction barrier of conventional fluorescence microscopy, allowing for bioimaging with nanometer resolution. It remains a challenge, however, to precisely localize photon-limited single molecules in 3D. We have developed a new localization-based imaging technique achieving almost isotropic subdiffraction resolution in 3D. A tilted mirror is used to generate a side view in addition to the front view of activated single emitters, allowing their 3D localization to be precisely determined for superresolution imaging. Because both front and side views are in focus, this method is able to efficiently collect emitted photons. The technique is simple to implement on a commercial fluorescence microscope, and especially suitable for biological samples with photon-limited chromophores such as endogenously expressed photoactivatable fluorescent proteins. Moreover, this method is relatively resistant to optical aberration, as it requires only centroid determination for localization analysis. Here we demonstrate the application of this method to 3D imaging of bacterial protein distribution and neuron dendritic morphology with subdiffraction resolution. PMID:20472826
Correia, Teresa; Koch, Maximilian; Ale, Angelique; Ntziachristos, Vasilis; Arridge, Simon
2016-02-21
Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regularisation tends to either oversmooth or generate very noisy reconstructions, depending on the regularisation strength. Edge preserving methods, such as anisotropic diffusion regularisation (AD), can preserve important features in the fluorescence image and smooth out noise. However, AD has limited ability to distinguish an edge from noise. We propose a patch-based anisotropic diffusion regularisation (PAD), where regularisation strength is determined by a weighted average according to the similarity between patches around voxels within a search window, instead of a simple local neighbourhood strategy. However, this method has higher computational complexity and, hence, we wavelet compress the patches (PAD-WT) to speed it up, while simultaneously taking advantage of the denoising properties of wavelet thresholding. Furthermore, structural information can be incorporated into the image reconstruction with PAD-WT to improve image quality and resolution. In this case, the weights used to average voxels in the image are calculated using the structural image, instead of the fluorescence image. The regularisation strength depends on both structural and fluorescence images, which guarantees that the method can preserve fluorescence information even when it is not structurally visible in the anatomical images. In part 1, we tested the method using a denoising problem. Here, we use simulated and in vivo mouse fDOT data to assess the algorithm performance. Our results show that the proposed PAD-WT method provides high quality and noise free images, superior to those obtained using AD.
Hu, Qinqin; Xu, Xiahong; Li, Zhanming; Zhang, Ying; Wang, Jianping; Fu, Yingchun; Li, Yanbin
2014-04-15
Acrylamide is a neurotoxin and potential carcinogen, but is found in various thermally processed foods such as potato chips, biscuits, and coffee. Simple and sensitive methods for on-line detection of acrylamide are needed to ensure food safety. In this paper, a novel fluorescent sensing method based on acrylamide polymerization-induced distance increase between quantum dots (QDs) was proposed for detecting acrylamide in potato chips. The functional QDs were prepared by their binding with N-acryloxysuccinimide (NAS), which was characterized by Fourier transform infrared (FR-IR) spectra. The carbon-carbon double bonds of NAS modified QDs polymerized with assistance of photo initiator under UV irradiation, leading to QDs getting closer along with fluorescence intensity decreasing. Acrylamide in the sample participated in the polymerization and induced an increase of fluorescence intensity. This method possessed a linear range from 3.5×10(-5) to 3.5 g L(-1) (r(2)=0.94) and a limit of detection of 3.5×10(-5) g L(-1). Although the sensitivity and specificity cannot be compared with standard LC-MS/MS analysis, this new method requires much less time and cost, which is promising for on-line rapid detection of acrylamide in food processing. © 2013 Published by Elsevier B.V.
A water-soluble conjugated polymer for protein identification and denaturation detection.
Xu, Qingling; Wu, Chunxian; Zhu, Chunlei; Duan, Xinrui; Liu, Libing; Han, Yuchun; Wang, Yilin; Wang, Shu
2010-12-03
Rapid and sensitive methods to detect proteins and protein denaturation have become increasingly needful in the field of proteomics, medical diagnostics, and biology. In this paper, we have reported the synthesis of a new cationic water-soluble conjugated polymer that contains fluorene and diene moieties in the backbone (PFDE) for protein identification by sensing an array of PFDE solutions in different ionic strengths using the linear discriminant analysis technique (LDA). The PFDE can form complexes with proteins by electrostatic and/or hydrophobic interactions and exhibits different fluorescence response. Three main factors contribute to the fluorescence response of PFDE, namely, the net charge density on the protein surface, the hydrophobic nature of the protein, and the metalloprotein characteristics. The denaturation of proteins can also be detected using PFDE as a fluorescent probe. The interactions between PFDE and proteins were also studied by dynamic light scattering (DLS) and isothermal titration microcalorimetry (ITC) techniques. In contrast to other methods based on conjugated polymers, the synthesis of a series of quencher or dye-labeled acceptors or protein substrates has been avoided in our method, which significantly reduces the cost and the synthetic complexity. Our method provides promising applications on protein identification and denaturation detection in a simple, fast, and label-free manner based on non-specific interaction-induced perturbation of PFDE fluorescence response.
Caries detection: current status and future prospects using lasers
NASA Astrophysics Data System (ADS)
Longbottom, Christopher
2000-03-01
Caries detection currently occupies a good deal of attention in the arena of dental research for a number of reasons. In searching for caries detection methods with greater accuracy than conventional technique researchers have used a variety of optical methods and have increasingly turned to the use of lasers. Several laser-based methods have been and are being assessed for both imaging and disease quantification techniques. The phenomenon of fluorescence of teeth and caries in laser light and the different effects produced by different wavelengths has been investigated by a number of workers in Europe. With an argon ion laser excitation, QLF (Quantified Laser Fluorescence) demonstrated a high correlation between loss of fluorescence intensity and enamel mineral loss in white spot lesions in free smooth surface lesions, both in vitro and in vivo. Recent work with a red laser diode source (655 nm), which appears to stimulate bacterial porphyrins to fluoresce, has demonstrated that a relatively simple device based on this phenomenon can provide sensitivity and specificity values of the order of 80% in vitro and in vivo for primary caries at occlusal sites. In vitro studies using a simulated in vivo methodology indicate that the device can produce sensitivity values of the order of 90% for primary caries at approximal sites.
Peng, Zhaofeng; Chen, Zhaopeng; Jiang, Jianhui; Zhang, Xiaobing; Shen, Guoli; Yu, Ruqin
2007-01-30
This study reports a novel, simple and sensitive immunoassay using fluorescence quenching caused by gold nanoparticles coated with antibody. The method is based on a non-competitive heterogeneous immunoassay of human IgG conducted by the typical procedure of sandwich immunocomplex formation. Goat anti-human IgG was first adsorbed on polystyrene microwells, and human IgG analyte was captured by the primary antibody and then sandwiched by antibody labeled with gold nanoparticles. The sandwich-type immunocomplex was subsequently dissociated by the mixed solution of sodium hydroxide and trisodium citrate, the solution obtained, which contains gold nanoparticles coated with antibody, was used to quench fluorescence. The fluorescence intensity of fluorescein at 517 nm was inversely proportional to the logarithm of the concentration of human IgG in the dynamic range of 10-5000 ng mL(-1) with a detection limit of 4.7 ng mL(-1). The electrochemical experiments and the UV-vis measurements were applied to demonstrate whether the immunogold was dissociated completely and whether the gold nanoparticles aggregated after being dissociated, respectively. The proposed system can be extended to detect target molecules such as other kinds of antigen and DNA strands, and has broad potential applications in disease diagnosis.
Dao, Lam; Glancy, Brian; Lucotte, Bertrand; Chang, Lin-Ching; Balaban, Robert S; Hsu, Li-Yueh
2015-01-01
SUMMARY This paper investigates a post-processing approach to correct spatial distortion in two-photon fluorescence microscopy images for vascular network reconstruction. It is aimed at in vivo imaging of large field-of-view, deep-tissue studies of vascular structures. Based on simple geometric modeling of the object-of-interest, a distortion function is directly estimated from the image volume by deconvolution analysis. Such distortion function is then applied to sub volumes of the image stack to adaptively adjust for spatially varying distortion and reduce the image blurring through blind deconvolution. The proposed technique was first evaluated in phantom imaging of fluorescent microspheres that are comparable in size to the underlying capillary vascular structures. The effectiveness of restoring three-dimensional spherical geometry of the microspheres using the estimated distortion function was compared with empirically measured point-spread function. Next, the proposed approach was applied to in vivo vascular imaging of mouse skeletal muscle to reduce the image distortion of the capillary structures. We show that the proposed method effectively improve the image quality and reduce spatially varying distortion that occurs in large field-of-view deep-tissue vascular dataset. The proposed method will help in qualitative interpretation and quantitative analysis of vascular structures from fluorescence microscopy images. PMID:26224257
MOD: An Organic Detector for the Future Exploration of Mars
NASA Technical Reports Server (NTRS)
Kminek, G.; Bada, J. L.; Botta, O.; Grunthaner, F.; Glavin, D. P.
1999-01-01
The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.
Capillary Array Waveguide Amplified Fluorescence Detector for mHealth
Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham
2013-01-01
Mobile Health (mHealth) analytical technologies are potentially useful for carrying out modern medical diagnostics in resource-poor settings. Effective mHealth devices for underserved populations need to be simple, low cost, and portable. Although cell phone cameras have been used for biodetection, their sensitivity is a limiting factor because currently it is too low to be effective for many mHealth applications, which depend on detection of weak fluorescent signals. To improve the sensitivity of portable phones, a capillary tube array was developed to amplify fluorescence signals using their waveguide properties. An array configured with 36 capillary tubes was demonstrated to have a ~100X increase in sensitivity, lowering the limit of detection (LOD) of mobile phones from 1000 nM to 10 nM for fluorescein. To confirm that the amplification was due to waveguide behavior, we coated the external surfaces of the capillaries with silver. The silver coating interfered with the waveguide behavior and diminished the fluorescence signal, thereby proving that the waveguide behavior was the main mechanism for enhancing optical sensitivity. The optical configuration described here is novel in several ways. First, the use of capillaries waveguide properties to improve detection of weak florescence signal is new. Second we describe here a three dimensional illumination system, while conventional angular laser waveguide illumination is spot (or line), which is functionally one-dimensional illumination, can illuminate only a single capillary or a single column (when a line generator is used) of capillaries and thus inherently limits the multiplexing capability of detection. The planar illumination demonstrated in this work enables illumination of a two dimensional capillary array (e.g. x columns and y rows of capillaries). In addition, the waveguide light propagation via the capillary wall provides a third dimension for illumination along the axis of the capillaries. Such an array can potentially be used for sensitive analysis of multiple fluorescent detection assays simultaneously. The simple phone based capillary array approach presented in this paper is capable of amplifying weak fluorescent signals thereby improving the sensitivity of optical detectors based on mobile phones. This may allow sensitive biological assays to be measured with low sensitivity detectors and may make mHealth practical for many diagnostics applications, especially in resource-poor and global health settings. PMID:24039345
NASA Astrophysics Data System (ADS)
Jukl, Jennifer Marie
Although biosensor technology is a broad and well-studied field, the progress of many novel sensor technologies faces challenges. These challenges range from simple design considerations to fundamental issues with the concept or approach. One of the most active fields of sensor research integrates fiber optics with specially engineered fluorescent molecules. This type of sensor typically utilizes a porous polymer or porous glass substrate to entrap the fluorescent (or fluorescently-tagged) molecule. Porous polymer hydrogels are generally favored due to their ease of fabrication, low cost, adaptability, and biocompatibility. While hydrogels are ideal for both functional molecule suspension and fluid diffusion, their porosity and hydrophilicity are not always advantageous. The largest drawback of these properties is the hydrogel swelling they produce and the resulting geometric changes. This project investigated the limitations of fluorescent hydrogel-based sensors and the effects of unpredictable structural changes hydrogels undergo during typical, unrestrained swelling. The significance of covalent incorporation of the sensing fluorophore into the hydrogel matrix is also explored. Leaching tests were conducted using polyacrylamide (PAm) hydrogels which were impregnated with one of two pH sensitive fluorophores, one which bonded covalently with the hydrogel matrix during polymerization (fluorescein o-acrylate), and one which did not (fluorescein sodium). Once determined to be effective, the covalently bonding fluorophore was used to create constrained-dimension fluorescent pH sensors. These sensors were tested for effectiveness and reproducibility. All data was collected using a laboratory grade optical fibers, a USB spectrometer, and SpectraSuite software (Ocean Optics, 2010) unless otherwise specified.
Fluorescent biosensors enabled by graphene and graphene oxide.
Zhang, Huan; Zhang, Honglu; Aldalbahi, Ali; Zuo, Xiaolei; Fan, Chunhai; Mi, Xianqiang
2017-03-15
During the past few years, graphene and graphene oxide (GO) have attracted numerous attentions for the potential applications in various fields from energy technology, biosensing to biomedical diagnosis and therapy due to their various functionalization, high volume surface ratio, unique physical and electrical properties. Among which, graphene and graphene oxide based fluorescent biosensors enabled by their fluorescence-quenching properties have attracted great interests. The fluorescence of fluorophore or dye labeled on probes (such as molecular beacon, aptamer, DNAzymes and so on) was quenched after adsorbed on to the surface of graphene. While in the present of the targets, due to the strong interactions between probes and targets, the probes were detached from the surface of graphene, generating dramatic fluorescence, which could be used as signals for detection of the targets. This strategy was simple and economy, together with great programmable abilities of probes; we could realize detection of different kinds of species. In this review, we first briefly introduced the history of graphene and graphene oxide, and then summarized the fluorescent biosensors enabled by graphene and GO, with a detailed account of the design mechanism and comparison with other nanomaterials (e.g. carbon nanotubes and gold nanoparticles). Following that, different sensing platforms for detection of DNAs, ions, biomolecules and pathogens or cells as well as the cytotoxicity issue of graphene and GO based in vivo biosensing were further discussed. We hope that this review would do some help to researchers who are interested in graphene related biosening research work. Copyright © 2016 Elsevier B.V. All rights reserved.
Sieracki, M E; Reichenbach, S E; Webb, K L
1989-01-01
The accurate measurement of bacterial and protistan cell biomass is necessary for understanding their population and trophic dynamics in nature. Direct measurement of fluorescently stained cells is often the method of choice. The tedium of making such measurements visually on the large numbers of cells required has prompted the use of automatic image analysis for this purpose. Accurate measurements by image analysis require an accurate, reliable method of segmenting the image, that is, distinguishing the brightly fluorescing cells from a dark background. This is commonly done by visually choosing a threshold intensity value which most closely coincides with the outline of the cells as perceived by the operator. Ideally, an automated method based on the cell image characteristics should be used. Since the optical nature of edges in images of light-emitting, microscopic fluorescent objects is different from that of images generated by transmitted or reflected light, it seemed that automatic segmentation of such images may require special considerations. We tested nine automated threshold selection methods using standard fluorescent microspheres ranging in size and fluorescence intensity and fluorochrome-stained samples of cells from cultures of cyanobacteria, flagellates, and ciliates. The methods included several variations based on the maximum intensity gradient of the sphere profile (first derivative), the minimum in the second derivative of the sphere profile, the minimum of the image histogram, and the midpoint intensity. Our results indicated that thresholds determined visually and by first-derivative methods tended to overestimate the threshold, causing an underestimation of microsphere size. The method based on the minimum of the second derivative of the profile yielded the most accurate area estimates for spheres of different sizes and brightnesses and for four of the five cell types tested. A simple model of the optical properties of fluorescing objects and the video acquisition system is described which explains how the second derivative best approximates the position of the edge. Images PMID:2516431
Xiong, Jin-Feng; Li, Jian-Xiao; Mo, Guang-Zhen; Huo, Jing-Pei; Liu, Jin-Yan; Chen, Xiao-Yun; Wang, Zhao-Yang
2014-12-05
1,3,5-Tri(1H-benzo[d]imidazol-2-yl)benzene derivatives, as a new kind of fluorescent chemosensor for the detection of nitroaromatic explosives, are designed and synthesized by simple N-hydrocarbylation. Among 16 obtained compounds, compound 4g has the best capability for detection of picric acid (PA), having good selectivity and high sensitivity. The detection of PA with 4g solution-coated paper strips at the picogram level is developed. A simple, portable, and low-cost method is provided for detecting PA in solution and contact mode.
Liu, Haisheng; Ma, Linbin; Ma, Changbei; Du, Junyan; Wang, Meilan; Wang, Kemin
2016-11-18
A new quencher-free Hg 2+ ion assay method was developed based on polymerase-assisted photoinduced electron transfer (PIET). In this approach, a probe is designed with a mercury ion recognition sequence (MRS) that is composed of two T-rich functional areas separated by a spacer of random bases at the 3'-end, and a sequence of stacked cytosines at the 5'-end, to which a fluorescein (FAM) is attached. Upon addition of Hg 2+ ions into this sensing system, the MRS folds into a hairpin structure at the 3'-end with Hg 2+ -mediated base pairs. In the presence of DNA polymerase, it will catalyze the extension reaction, resulting in the formation of stacked guanines, which will instantly quench the fluorescence of FAM through PIET. Under optimal conditions, the limit of detection for Hg 2+ ions was estimated to be 5 nM which is higher than the US Environmental Protection Agency (EPA) standard limit. In addition, no labeling with a quencher was requiring, and the present method is fairly simple, fast and low cost. It is expected that this cost-effective fluorescence method might hold considerable potential in the detection of Hg 2+ ions in real biological and environmental samples.
Easy preparation of a large-size random gene mutagenesis library in Escherichia coli.
You, Chun; Percival Zhang, Y-H
2012-09-01
A simple and fast protocol for the preparation of a large-size mutant library for directed evolution in Escherichia coli was developed based on the DNA multimers generated by prolonged overlap extension polymerase chain reaction (POE-PCR). This protocol comprised the following: (i) a linear DNA mutant library was generated by error-prone PCR or shuffling, and a linear vector backbone was prepared by regular PCR; (ii) the DNA multimers were generated based on these two DNA templates by POE-PCR; and (iii) the one restriction enzyme-digested DNA multimers were ligated to circular plasmids, followed by transformation to E. coli. Because the ligation efficiency of one DNA fragment was several orders of magnitude higher than that of two DNA fragments for typical mutant library construction, it was very easy to generate a mutant library with a size of more than 10(7) protein mutants per 50 μl of the POE-PCR product. Via this method, four new fluorescent protein mutants were obtained based on monomeric cherry fluorescent protein. This new protocol was simple and fast because it did not require labor-intensive optimizations in restriction enzyme digestion and ligation, did not involve special plasmid design, and enabled constructing a large-size mutant library for directed enzyme evolution within 1 day. Copyright © 2012 Elsevier Inc. All rights reserved.
Dubber, Donata; Gill, Laurence W
2017-12-15
Rural river catchments are impacted by diffuse pollution sources from agricultural practices and on-site domestic wastewater treatment systems (DWWTS), mainly septic tanks. Methods that can distinguish between contamination sources will significantly increase water management efficiency as they will allow for the development and application of targeted remediation measures. Fluorescent whitening compounds (FWC), are used as optical brighteners in laundry detergents and enter the environment through the discharge of domestic wastewater effluents. Due to their human specific source and potential simple fluorometric measurement this represents a very attractive method to be used by state monitoring agencies. In this study the suitability of FWCs as chemical indicators for human faecal contamination has been investigated in rural Irish catchments. It was found that no quantitative measurements are possible for FWCs in natural waters when using simple fluorometric methods. Hence a simple presence/absence approach needs to be applied. The detectability of FWCs was quantified and found to decrease with higher organic matter content of the river water which has its own fluorescence. This enabled the establishment of equations to predict detection limits and assess the method's suitability for individual catchments based on organic matter concentrations. Furthermore a modified photodecay method is suggested that increases sensitivity of the technique by up to 59%. Applications at rural study sites found some removal of FWCs in percolation areas of DWWTSs but they were still detectable 40 cm below the infiltration depth. FWCs were also detected as distinguishable peaks in impacted streams where septic tank effluents have a high contribution to the river flow. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kubo, Takuya; Kanemori, Koichi; Kusumoto, Risa; Kawai, Takayuki; Sueyoshi, Kenji; Naito, Toyohiro; Otsuka, Koji
2015-01-01
An effective separation and detection procedure for sugars by capillary electrophoresis (CE) using a complexation between quinolineboronic acid (QBA) and multiple hydroxyl structure of sugar alcohol is reported. We investigated the variation of fluorescence spectra of a variety of QBAs with sorbitol at a wide range of pH conditions and then found that 5-isoQBA strongly enhanced the fluorescence intensity by the complexation at basic pH conditions. The other sugar alcohols having multiple hydroxyls also revealed the enhancement of the fluorescence intensity with 5-isoQBA, whereas the alternation of the intensity was not found in the sugars such as glucose. After optimization of the 5-isoQBA concentration and pH of the buffered solution in CE analysis, 6 sugar alcohols were successfully separated in the order based on the formation constants with 5-isoQBA, which were calculated from the variation of the fluorescence intensity with each sugar alcohol and 5-isoQBA. Furthermore, the limits of detection for sorbitol and xylitol by the CE method were estimated at 15 and 27 μM, respectively.
Zhang, Yunyi; Li, Yongxin; Zhang, Cuiyun; Zhang, Qingfeng; Huang, Xinan; Yang, Meiding; Shahzad, Sohail Anjum; Lo, Kenneth Kam-Wing; Yu, Cong; Jiang, Shichun
2017-08-01
A fluorescence turn-on assay for alkaline phosphatase (ALP) activity is developed through the controlled release of polyethyleneimine-capped copper nanoclusters (PEI-capped CuNCs) from the MnO 2 nanosheets. In an aqueous solution, the positively charged PEI-capped CuNCs could be adsorbed onto the surface of the negatively charged MnO 2 nanosheets. Such adsorption through favorable electrostatic interactions could efficiently quench the nanocluster fluorescence emission via resonance energy transfer from the PEI-capped CuNCs to the MnO 2 nanosheets. 2-Phospho-L-ascorbic acid (AAP) could be hydrolyzed to L-ascorbic acid (AA) in the presence of ALP. AA could reduce MnO 2 into Mn 2+ and trigger the disintegration of the MnO 2 nanosheets. As a result, the CuNCs were released and the quenched fluorescence was recovered efficiently. The detection strategy is simple, inexpensive, sensitive, selective, with low toxicity, and has better biocompatibility. The newly fabricated biosensor for ALP activity will potentially make it a robust candidate for numerous biological and biomedical applications.
Yang, Qiong; Tan, Xuanping; Yang, Jidong
2016-02-01
A sensitive and simple method for the determination of enoxacin (ENX) was developed based on the fluorescence quenching effect of ENX for glutathione (GSH)-capped CdTe quantum dots (QDs). Under optimum conditions, a good linear relationship was obtained from 4.333 × 10(-9) mol⋅L(-1) to 1.4 × 10(-5) mol⋅L(-1) with a correlation coefficient (R) of 0.9987, and the detection limit (3σ/K) was 1.313 × 10(-9) mol⋅L(-1). The corresponding mechanism has been proposed on the basis of electron transfer supported by ultraviolet-visible (UV) light absorption, fluorescence spectroscopy, and the measurement of fluorescence lifetime. The method has been applied to the determination of ENX in pharmaceutical formulations (enoxacin gluconate injections and commercial tablets) with satisfactory results. The proposed method manifested several advantages such as high sensitivity, short analysis time, low cost and ease of operation. Copyright © 2015 John Wiley & Sons, Ltd.
A novel fluorescent assay for edaravone with aqueous functional CdSe quantum dots
NASA Astrophysics Data System (ADS)
Liao, Ping; Yan, Zheng-Yu; Xu, Zhi-Ji; Sun, Xiao
2009-06-01
Aqueous thiol-capped CdSe QDs with a narrow, symmetric emission were prepared under a low temperature. Based on the fluorescence enhancement of thiol-stabilized CdSe quantum dots (QDs) caused by edaravone, a simple, rapid and specific quantitative method was proposed to the edaravone determination. The concentration dependence of fluorescence intensity followed the binding of edaravone to surface of the thiol-capped CdSe QDs was effectively described by a modified Langmuir-type binding isotherm. Factors affecting the fluorescence detection for edaravone with thiol-stabilized CdSe QDs were studied, such as the effect of pH, reaction time, the concentration of CdSe QDs and so on. Under the optimal conditions, the calibration plot of C/( I - I0) with concentration of edaravone was linear in the range of (1.45-17.42) μg/mL (0.008-0.1 μmol/L) with correlation coefficient of 0.998. The limit of detection (LOD) (3 σ/ κ) was 0.15 μg/mL (0.0009 μmol/mL). Possible interaction mechanism was discussed.
Fernández, A.; Grüner-Nielsen, L.; Andreana, M.; Stadler, M.; Kirchberger, S.; Sturtzel, C.; Distel, M.; Zhu, L.; Kautek, W.; Leitgeb, R.; Baltuska, A.; Jespersen, K.; Verhoef, A.
2017-01-01
A simple and completely all-fiber Yb chirped pulse amplifier that uses a dispersion matched fiber stretcher and a spliced-on hollow core photonic bandgap fiber compressor is applied in nonlinear optical microscopy. This stretching-compression approach improves compressibility and helps to maximize the fluorescence signal in two-photon laser scanning microscopy as compared with approaches that use standard single mode fibers as stretcher. We also show that in femtosecond all-fiber systems, compensation of higher order dispersion terms is relevant even for pulses with relatively narrow bandwidths for applications relying on nonlinear optical effects. The completely all-fiber system was applied to image green fluorescent beads, a stained lily-of-the-valley root and rat-tail tendon. We also demonstrated in vivo imaging in zebrafish larvae, where we simultaneously measure second harmonic and fluorescence from two-photon excited red-fluorescent protein. Since the pulses are compressed in a fiber, this source is especially suited for upgrading existing laser scanning (confocal) microscopes with multiphoton imaging capabilities in space restricted settings or for incorporation in endoscope-based microscopy. PMID:28856032
Jugder, Bat-Erdene; Welch, Jeffrey; Braidy, Nady
2016-01-01
Hydrogenases are metalloenzymes that reversibly catalyse the oxidation or production of molecular hydrogen (H2). Amongst a number of promising candidates for application in the oxidation of H2 is a soluble [Ni–Fe] uptake hydrogenase (SH) produced by Cupriavidus necator H16. In the present study, molecular characterisation of the SH operon, responsible for functional SH synthesis, was investigated by developing a green fluorescent protein (GFP) reporter system to characterise PSH promoter activity using several gene cloning approaches. A PSH promoter-gfp fusion was successfully constructed and inducible GFP expression driven by the PSH promoter under de-repressing conditions in heterotrophic growth media was demonstrated in the recombinant C. necator H16 cells. Here we report the first successful fluorescent reporter system to study PSH promoter activity in C. necator H16. The fusion construct allowed for the design of a simple screening assay to evaluate PSH activity. Furthermore, the constructed reporter system can serve as a model to develop a rapid fluorescent based reporter for subsequent small-scale process optimisation experiments for SH expression. PMID:27547572
Alarfaj, Nawal A; El-Tohamy, Maha F
2013-01-01
A simple and sensitive spectrofluorimetric method was developed for the determination of Ribavirin in pharmaceutical formulations. The proposed method was based on the fluorescence spectral behaviour of Ribavirin in a sodium dodecyl sulfate (SDS) micellar system. In an aqueous acetate buffer solution of pH 4.0, the fluorescence intensity of Ribavirin was significantly enhanced by about 217% in the presence of SDS. Fluorescence intensity was measured at 396 nm after excitation at 270 nm for Ribavirin. The fluorescence-concentration plot was rectilinear over the range of 0.01-3.0 µg/mL for Ribavirin with a lower detection limit of 5.02 x 10(-3) µg/mL. The method was successfully applied to the analysis of the drug in its commercial capsules. Results were in good agreement with those obtained with the official method. The application of the proposed method was extended to stability studies of Ribavirin after exposure to different forced degradation conditions such as acidic, alkaline, photo and oxidative conditions according to ICH guidelines. Copyright © 2012 John Wiley & Sons, Ltd.
Alarfaj, Nawal A; Aly, Fatma A
2012-01-01
A simple and sensitive spectrofluorimetric method was developed for the determination of ezetimibe in its pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behavior of ezetimibe in sodium dodecyl sulfate (SDS) micellar system. In aqueous solution of acetate buffer pH 5.0, the fluorescence intensity of ezetimibe was greatly enhanced, 200% enhancement, in the presence of SDS. The fluorescence intensity of ezetimibe was measured at 380 nm after excitation at 268 nm. The fluorescence-concentration plot was rectilinear over the range of 0.03-3.0 μg/mL with lower detection limit of 3.08 × 10(-3) μg/mL. The method was successfully applied to the analysis of ezetimibe in its commercial tablets; the results were in good agreement with those obtained with the reported method. The application of the proposed method was extended to the stability studies of ezetimibe after exposure to different forced degradation conditions, such as acidic, alkaline, photo and oxidative conditions, according to ICH guidelines.
Fernández, A; Grüner-Nielsen, L; Andreana, M; Stadler, M; Kirchberger, S; Sturtzel, C; Distel, M; Zhu, L; Kautek, W; Leitgeb, R; Baltuska, A; Jespersen, K; Verhoef, A
2017-08-01
A simple and completely all-fiber Yb chirped pulse amplifier that uses a dispersion matched fiber stretcher and a spliced-on hollow core photonic bandgap fiber compressor is applied in nonlinear optical microscopy. This stretching-compression approach improves compressibility and helps to maximize the fluorescence signal in two-photon laser scanning microscopy as compared with approaches that use standard single mode fibers as stretcher. We also show that in femtosecond all-fiber systems, compensation of higher order dispersion terms is relevant even for pulses with relatively narrow bandwidths for applications relying on nonlinear optical effects. The completely all-fiber system was applied to image green fluorescent beads, a stained lily-of-the-valley root and rat-tail tendon. We also demonstrated in vivo imaging in zebrafish larvae, where we simultaneously measure second harmonic and fluorescence from two-photon excited red-fluorescent protein. Since the pulses are compressed in a fiber, this source is especially suited for upgrading existing laser scanning (confocal) microscopes with multiphoton imaging capabilities in space restricted settings or for incorporation in endoscope-based microscopy.
Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe
2018-03-15
Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation. Copyright © 2017 Elsevier B.V. All rights reserved.
Fang, Aijin; Chen, Hongyu; Li, Haitao; Liu, Meiling; Zhang, Youyu; Yao, Shouzhuo
2017-01-15
A dual-functional platform for the sensing of acetylcholinesterase (AChE) activity and cadmium ions (Cd 2+ ) was developed based on the fluorescence resonance energy transfer (FRET) between NaYF 4 :Yb,Er upconversion nanoparticles (UCNPs) and gold nanoparticles (AuNPs) via glutathione regulation. The detection mechanism is based on the fact that AuNPs can quench the fluorescence of UCNPs. AChE catalyzes the hydrolysis of acetylthiocholine (ATC) into thiocholine which reacts with AuNPs by S-Au conjunction and results the aggregation of AuNPs and change in fluorescence of UCNPs. Therefore, the AChE activity can be detected through the changes of the color of solution and fluorescence recovery of UCNPs. However, the presence of glutathione (GSH) can protect AuNPs from aggregation and enlarge the inter-particle distance between AuNPs and UCNPs. When Cd 2+ is added into the stable mixture of AuNPs, GSH and AChE/ATC, Cd 2+ could interact with GSH to form a spherical shaped (GSH) 4 Cd complex, which decreases the free GSH on the surface of AuNPs to weaken the stability of AuNPs and lead to the easily aggregation of them in the system. The aggregated-AuNPs are released from the surface of UCNPs, which results in the fluorescence of UCNPs gradually recovered. Under the optimized conditions, the detection limits of AChE activity and Cd 2+ are estimated to be 0.015mU/mL and 0.2µM, respectively. The small molecules regulated dual-functional platform based on UCNPs/AuNPs is a simple, label-free method and can be applied for the turn-on fluorescence detection of AChE activity in human serum and Cd 2+ in real water samples. The present work demonstrates a general strategy for the design of small molecules regulated multifunctional platform and will be expanded for different areas in the future. Copyright © 2016 Elsevier B.V. All rights reserved.
Simple and cost-effective fluorescent labeling of 5-hydroxymethylcytosine
NASA Astrophysics Data System (ADS)
Shahal, Tamar; Green, Ori; Hananel, Uri; Michaeli, Yael; Shabat, Doron; Ebenstein, Yuval
2016-12-01
The nucleobase 5-hydroxymethylcytosine (5-hmC), a modified form of cytosine, is an important epigenetic mark related to regulation of gene expression. 5-hmC levels are highly dynamic during early development and are modulated during the progression of neurodegenerative disease and cancer. We describe a spectroscopic method for the global quantification of 5-hmC in genomic DNA. This method relies on the enzymatic glucosylation of 5-hmC, followed by a glucose oxidation step that results in the formation of aldehyde moieties that are covalently linked to a fluorescent reporter by oxime ligation. The fluorescence intensity of the labeled sample is directly proportional to its 5-hmC content. We show that this simple and cost-effective technique is suitable for quantification of 5-hmC content in different mouse tissues.
Fluorescent carbon nanodots facilely extracted from Coca Cola for temperature sensing
NASA Astrophysics Data System (ADS)
Li, Feiming; Chen, Qiaoling; Cai, Zhixiong; Lin, Fangyuan; Xu, Wei; Wang, Yiru; Chen, Xi
2017-12-01
A novel method for the fabrication of carbon nanodots (CDs) is introduced: extracting CDs from the well-known soft drink Coca Cola via dialysis. The obtained CDs are of good monodispersity with a narrow size distribution (average diameter of 3.0 nm), good biocompatibility, high solubility (about 180 mg ml-1) and stable fluorescence even at a high salt concentration. Furthermore, they are sensitive to the temperature change with a linear relationship between the fluorescence intensity and temperature from 5 °C-95 °C. The CDs have been applied in high stable temperature sensing. This protocol is quite simple, green, cost-effective and technologically simple, which might be used for a range of applications including sensing, catalysts, drug and gene delivery, and so on.
Fluorescent carbon nanodots facilely extracted from Coca Cola for temperature sensing.
Li, Feiming; Chen, Qiaoling; Cai, Zhixiong; Lin, Fangyuan; Xu, Wei; Wang, Yiru; Chen, Xi
2017-10-16
A novel method for the fabrication of carbon nanodots (CDs) is introduced: extracting CDs from the well-known soft drink Coca Cola via dialysis. The obtained CDs are of good monodispersity with a narrow size distribution (average diameter of 3.0 nm), good biocompatibility, high solubility (about 180 mg ml -1 ) and stable fluorescence even at a high salt concentration. Furthermore, they are sensitive to the temperature change with a linear relationship between the fluorescence intensity and temperature from 5 °C-95 °C. The CDs have been applied in high stable temperature sensing. This protocol is quite simple, green, cost-effective and technologically simple, which might be used for a range of applications including sensing, catalysts, drug and gene delivery, and so on.
Gbaj, A; Bichenkova, Ev; Walsh, L; Savage, He; Sardarian, Ar; Etchells, Ll; Gulati, A; Hawisa, S; Douglas, Kt
2009-12-01
The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5'-bispyrene and 3'-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5'-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.
Fantuzzo, J. A.; Mirabella, V. R.; Zahn, J. D.
2017-01-01
Abstract Synapse formation analyses can be performed by imaging and quantifying fluorescent signals of synaptic markers. Traditionally, these analyses are done using simple or multiple thresholding and segmentation approaches or by labor-intensive manual analysis by a human observer. Here, we describe Intellicount, a high-throughput, fully-automated synapse quantification program which applies a novel machine learning (ML)-based image processing algorithm to systematically improve region of interest (ROI) identification over simple thresholding techniques. Through processing large datasets from both human and mouse neurons, we demonstrate that this approach allows image processing to proceed independently of carefully set thresholds, thus reducing the need for human intervention. As a result, this method can efficiently and accurately process large image datasets with minimal interaction by the experimenter, making it less prone to bias and less liable to human error. Furthermore, Intellicount is integrated into an intuitive graphical user interface (GUI) that provides a set of valuable features, including automated and multifunctional figure generation, routine statistical analyses, and the ability to run full datasets through nested folders, greatly expediting the data analysis process. PMID:29218324
NASA Astrophysics Data System (ADS)
Ha, Na-Reum; Jung, In-Pil; La, Im-Joung; Jung, Ho-Sup; Yoon, Moon-Young
2017-01-01
Overuse of antibiotics has caused serious problems, such as appearance of super bacteria, whose accumulation in the human body through the food chain is a concern. Kanamycin is a common antibiotic used to treat diverse infections; however, residual kanamycin can cause many side effects in humans. Thus, development of an ultra-sensitive, precise, and simple detection system for residual kanamycin in food products is urgently needed for food safety. In this study, we identified kanamycin-binding aptamers via a new screening method, and truncated variants were analyzed for optimization of the minimal sequence required for target binding. We found various aptamers with high binding affinity from 34.7 to 669 nanomolar Kdapp values with good specificity against kanamycin. Furthermore, we developed a reduced graphene oxide (RGO)-based fluorescent aptasensor for kanamycin detection. In this system, kanamycin was detected at a concentration as low as 1 pM (582.6 fg/mL). In addition, this method could detect kanamycin accurately in kanamycin-spiked blood serum and milk samples. Consequently, this simple, rapid, and sensitive kanamycin detection system with newly structural and functional analysis aptamer exhibits outstanding detection compared to previous methods and provides a new possibility for point of care testing and food safety.
FAITH – Fast Assembly Inhibitor Test for HIV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague
Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less
NASA Astrophysics Data System (ADS)
El-ghobashy, Mohamed R.; Yehia, Ali M.; Helmy, Aya H.; Youssef, Nadia F.
2018-01-01
Simple, smart and sensitive normal fluorescence and stability-indicating derivative synchronous spectrofluorimetric methods have been developed and validated for the determination of gliquidone in the drug substance and drug product. Normal spectrofluorimetric method of gliquidone was established in methanol at λ excitation 225 nm and λ emission 400 nm in concentration range 0.2-3 μg/ml with LOD equal 0.028. The fluorescence quantum yield of gliquidone was calculated using quinine sulfate as a reference and found to be 0.542. Stability-indicating first and third derivative synchronous fluorescence spectroscopy were successfully utilized to overcome the overlapped spectra in normal fluorescence of gliquidone and its alkaline degradation product. Derivative synchronous methods are based on using the synchronous fluorescence of gliquidone and its degradation product in methanol at Δ λ50 nm. Peak amplitude in the first derivative of synchronous fluorescence spectra was measured at 309 nm where degradation product showed zero-crossing without interference. The peak amplitudes in the third derivative of synchronous fluorescence spectra, peak to trough were measured at 316,329 nm where degradation product showed zero-crossing. The different experimental parameters affecting the normal and synchronous fluorescence intensity of gliquidone were studied and optimized. Moreover, the cited methods have been validated as per ICH guidelines. The peak amplitude-concentration plots of the derivative synchronous fluorescence were linear over the concentration range 0.05-2 μg/ml for gliquidone. Limits of detection were 0.020 and 0.022 in first and third derivative synchronous spectra, respectively. The adopted methods were successfully applied to commercial tablets and the results demonstrated that the derivative synchronous fluorescence spectroscopy is a powerful stability-indicating method, suitable for routine use with a short analysis time. Statistical comparison between the results obtained by normal fluorescence and derivative synchronous methods and the official one using student's t-test and F-ratio showed no significant difference regarding accuracy and precision.
Dean, Kimberly M; Grayhack, Elizabeth J
2012-12-01
We have developed a robust and sensitive method, called RNA-ID, to screen for cis-regulatory sequences in RNA using fluorescence-activated cell sorting (FACS) of yeast cells bearing a reporter in which expression of both superfolder green fluorescent protein (GFP) and yeast codon-optimized mCherry red fluorescent protein (RFP) is driven by the bidirectional GAL1,10 promoter. This method recapitulates previously reported progressive inhibition of translation mediated by increasing numbers of CGA codon pairs, and restoration of expression by introduction of a tRNA with an anticodon that base pairs exactly with the CGA codon. This method also reproduces effects of paromomycin and context on stop codon read-through. Five key features of this method contribute to its effectiveness as a selection for regulatory sequences: The system exhibits greater than a 250-fold dynamic range, a quantitative and dose-dependent response to known inhibitory sequences, exquisite resolution that allows nearly complete physical separation of distinct populations, and a reproducible signal between different cells transformed with the identical reporter, all of which are coupled with simple methods involving ligation-independent cloning, to create large libraries. Moreover, we provide evidence that there are sequences within a 9-nt library that cause reduced GFP fluorescence, suggesting that there are novel cis-regulatory sequences to be found even in this short sequence space. This method is widely applicable to the study of both RNA-mediated and codon-mediated effects on expression.
An integrated optics microfluidic device for detecting single DNA molecules.
Krogmeier, Jeffrey R; Schaefer, Ian; Seward, George; Yantz, Gregory R; Larson, Jonathan W
2007-12-01
A fluorescence-based integrated optics microfluidic device is presented, capable of detecting single DNA molecules in a high throughput and reproducible manner. The device integrates microfluidics for DNA stretching with two optical elements for single molecule detection (SMD): a plano-aspheric refractive lens for fluorescence excitation (illuminator) and a solid parabolic reflective mirror for fluorescence collection (collector). Although miniaturized in size, both optical components were produced and assembled onto the microfluidic device by readily manufacturable fabrication techniques. The optical resolution of the device is determined by the small and relatively low numerical aperture (NA) illuminator lens (0.10 effective NA, 4.0 mm diameter) that delivers excitation light to a diffraction limited 2.0 microm diameter spot at full width half maximum within the microfluidic channel. The collector (0.82 annular NA, 15 mm diameter) reflects the fluorescence over a large collection angle, representing 71% of a hemisphere, toward a single photon counting module in an infinity-corrected scheme. As a proof-of-principle experiment for this simple integrated device, individual intercalated lambda-phage DNA molecules (48.5 kb) were stretched in a mixed elongational-shear microflow, detected, and sized with a fluorescence signal to noise ratio of 9.9 +/-1.0. We have demonstrated that SMD does not require traditional high numerical aperture objective lenses and sub-micron positioning systems conventionally used in many applications. Rather, standard manufacturing processes can be combined in a novel way that promises greater accessibility and affordability for microfluidic-based single molecule applications.
Exciton-controlled fluorescence: application to hybridization-sensitive fluorescent DNA probe.
Okamoto, Akimitsu; Ikeda, Shuji; Kubota, Takeshi; Yuki, Mizue; Yanagisawa, Hiroyuki
2009-01-01
A hybridization-sensitive fluorescent probe has been designed for nucleic acid detection, using the concept of fluorescence quenching caused by the intramolecular excitonic interaction of fluorescence dyes. We synthesized a doubly thiazole orange-labeled nucleotide showing high fluorescence intensity for a hybrid with the target nucleic acid and effective quenching for the single-stranded state. This exciton-controlled fluorescent probe was applied to living HeLa cells using microinjection to visualize intracellular mRNA localization. Immediately after injection of the probe into the cell, fluorescence was observed from the probe hybridizing with the target RNA. This fluorescence rapidly decreased upon addition of a competitor DNA. Multicoloring of this probe resulted in the simple simultaneous detection of plural target nucleic acid sequences. This probe realized a large, rapid, reversible change in fluorescence intensity in sensitive response to the amount of target nucleic acid, and facilitated spatiotemporal monitoring of the behavior of intracellular RNA.
NASA Astrophysics Data System (ADS)
Cui, Peng; Jiang, Xuekai; Sun, Junyong; Zhang, Qiang; Gao, Feng
2017-06-01
A structurally simple, water-soluble rhodamine-derivatived fluorescent probe, which is responsive to acidic pH, was conveniently synthesized via a one-step condensation reaction of rhodamine B hydrazide and 4-formybenzene-1,3-disulfonate. As a stable and highly sensitive pH sensor, the probe displays an approximately 50-fold fluorescence enhancement over the pH range of 7.16-4.89 as the structure of probe changes from spirocyclic (weak fluorescent) to ring-open (strong fluorescent) with decreasing pH. The synthesized fluorescent probe is applied to the detection of pH changes in vitro and in vivo bioimaging of immortalized gastric cancer cells, with satisfactory results.
Fluorogenic DNA Sequencing in PDMS Microreactors
Sims, Peter A.; Greenleaf, William J.; Duan, Haifeng; Xie, X. Sunney
2012-01-01
We have developed a multiplex sequencing-by-synthesis method combining terminal-phosphate labeled fluorogenic nucleotides (TPLFNs) and resealable microreactors. In the presence of phosphatase, the incorporation of a non-fluorescent TPLFN into a DNA primer by DNA polymerase results in a fluorophore. We immobilize DNA templates within polydimethylsiloxane (PDMS) microreactors, sequentially introduce one of the four identically labeled TPLFNs, seal the microreactors, allow template-directed TPLFN incorporation, and measure the signal from the fluorophores trapped in the microreactors. This workflow allows sequencing in a manner akin to pyrosequencing but without constant monitoring of each microreactor. With cycle times of <10 minutes, we demonstrate 30 base reads with ∼99% raw accuracy. “Fluorogenic pyrosequencing” combines benefits of pyrosequencing, such as rapid turn-around, native DNA generation, and single-color detection, with benefits of fluorescence-based approaches, such as highly sensitive detection and simple parallelization. PMID:21666670
Wang, Rui; Zhang, Fang; Wang, Liu; Qian, Wenjuan; Qian, Cheng; Wu, Jian; Ying, Yibin
2017-04-18
On-site monitoring the plantation of genetically modified (GM) crops is of critical importance in agriculture industry throughout the world. In this paper, a simple, visual and instrument-free method for instant on-site detection of GTS 40-3-2 soybean has been developed. It is based on body-heat recombinase polymerase amplification (RPA) and followed with naked-eye detection via fluorescent DNA dye. Combining with extremely simplified sample preparation, the whole detection process can be accomplished within 10 min and the fluorescent results can be photographed by an accompanied smart phone. Results demonstrated a 100% detection rate for screening of practical GTS 40-3-2 soybean samples by 20 volunteers under different ambient temperatures. This method is not only suitable for on-site detection of GM crops but also demonstrates great potential to be applied in other fields.
Li, Jiang; Bifano, Thomas G.; Mertz, Jerome
2016-01-01
Abstract. We describe a wavefront sensor strategy for the implementation of adaptive optics (AO) in microscope applications involving thick, scattering media. The strategy is based on the exploitation of multiple scattering to provide oblique back illumination of the wavefront-sensor focal plane, enabling a simple and direct measurement of the flux-density tilt angles caused by aberrations at this plane. Advantages of the sensor are that it provides a large measurement field of view (FOV) while requiring no guide star, making it particularly adapted to a type of AO called conjugate AO, which provides a large correction FOV in cases when sample-induced aberrations arise from a single dominant plane (e.g., the sample surface). We apply conjugate AO here to widefield (i.e., nonscanning) fluorescence microscopy for the first time and demonstrate dynamic wavefront correction in a closed-loop implementation. PMID:27653793
Improved LED backlight with unique color and intensity control and NVIS capability
NASA Astrophysics Data System (ADS)
Herman, Robert; Zagar, Pete; Ulijasz, Ted; Hansen, Hans C.; Ellner, Fred
2006-05-01
Currently deployed conventional flat panel AMLCD displays employ fluorescent lamp backlights to achieve the required lighting levels for cockpits in high performance aircraft. Advances have been made in backlighting technology by replacing fluorescent lamps with high performance LEDs. However, these new LED-based backlights are lacking in control of color and luminance intensity especially when related to NVIS requirements in a cockpit. This paper describes a unique integration of LED, electronic, and optical components to meet the requirements of high performance aircraft over their extreme range of operating environments. The LED-based backlight utilizes state-of-art components to enable daylight, night, and NVIS requirements to be implemented in a simple cost-effective package. The performance results presented highlight the advantages of this new design when compared to currently available backlighting designs. Techniques as described in section 2 of this paper are covered under patent application to the US and International Patent Offices.
Dai, Gang; Aodeng, Gao-wa
2004-07-01
A new spectrofluorimetric method for the determination of trace amount of Fe(III) has been developed. This method is based on the fluorescence quenching of 2,4-dichro-phenylfluorone due to the formation of complex Fe(III)-DCIPF. In pH 5.2-5.9 buffer solution, Fe (III) and DCIPF react on each other to form a red complex. Its composition was established by method of continuous variations and molar-ratio as Fe(III): DCIPF = 1:4, the excitation and emission wavelengths were found to be 282 and 560 nm, respectively. There is a linear relationship in the range 4-24 ng x mL(-1) for Fe(III). This method is simple and rapid, and has been applied to the determination of trace iron in Chinese herbal medicine and tea samples with satisfactory results.
Kanagaraj, Kuppusamy; Pitchumani, Kasi
2014-01-01
A simple, highly selective and sensitive colorimetric system for the detection of fluoride ion in an aqueous medium has been developed using 2-(2-hydroxyphenyl)-2,3-dihydroquinolin-4(1H)-one. This system allows selective "turn-on" fluorescence detection of fluoride ion, which is found to be dependent upon guest basicity. An excited-state proton transfer is proposed to be the signaling mechanism, which is rationalized by DFT and TD-DFT calculations. The present sensor can also be applied to detect fluoride levels in real water samples. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mayberry, Addison; Perkins, David L.; Holcomb, Daniel E.
2018-01-01
Miniaturized imaging devices have pushed the boundaries of point-of-care imaging, but existing mobile-phone-based imaging systems do not exploit the full potential of smart phones. This work demonstrates the use of simple imaging configurations to deliver superior image quality and the ability to handle a wide range of biological samples. Results presented in this work are from analysis of fluorescent beads under fluorescence imaging, as well as helminth eggs and freshwater mussel larvae under white light imaging. To demonstrate versatility of the systems, real time analysis and post-processing results of the sample count and sample size are presented in both still images and videos of flowing samples. PMID:29509786
Sensitive determination of carbohydrates by fluorimetric method with Ce(IV) and sodium triphosphate.
Yang, Jinghe; Cao, Xihui; Sun, Changxia; Wu, Xia; Li, Lei
2004-05-01
A new simple and sensitive fluorimetric method for the determination of carbohydrates is described. The method is based on the reaction between carbohydrates and Ce(IV) in the presence of sulfuric acid. All the reductive carbohydrates can be detected indirectly by the fluorescence of Ce(III) produced. The addition of sodium triphate enhances the sensitivity of the method by more than 10-folds. Under optimum conditions, an excellent linear relationship was obtained between the fluorescence intensity and the concentration of carbohydrates. The limits of detection lie in the range of 9.3 x 10(-10) - 1.3 x 10(-9) mol/L. As compared to the normal fluorimetric method, the proposed method is faster and more sensitive.
Zhang, Tianyou; Zhao, Bo; Chu, Bei; Li, Wenlian; Su, Zisheng; Yan, Xingwu; Liu, Chengyuan; Wu, Hairuo; Gao, Yuan; Jin, Fangming; Hou, Fuhua
2015-05-15
Exciplex is well known as a charge transfer state formed between electron-donating and electron-accepting molecules. However, exciplex based organic light emitting diodes (OLED) often performed low efficiencies relative to pure phosphorescent OLED and could hardly be used to construct white OLED (WOLED). In this work, a new mechanism is developed to realize efficient WOLED with extremely simple structure by redistributing the energy of triplet exciplex to both singlet exciplex and the orange dopant. The micro process of energy transfer could be directly examined by detailed photoluminescence decay measurement and time resolved photoluminescence analysis. This strategy overcomes the low reverse intersystem crossing efficiency of blue exciplex and complicated device structure of traditional WOLED, enables us to achieve efficient hybrid WOLEDs. Based on this mechanism, we have successfully constructed both exciplex-fluorescence and exciplex-phosphorescence hybrid WOLEDs with remarkable efficiencies.
NASA Astrophysics Data System (ADS)
Zhang, Tianyou; Zhao, Bo; Chu, Bei; Li, Wenlian; Su, Zisheng; Yan, Xingwu; Liu, Chengyuan; Wu, Hairuo; Gao, Yuan; Jin, Fangming; Hou, Fuhua
2015-05-01
Exciplex is well known as a charge transfer state formed between electron-donating and electron-accepting molecules. However, exciplex based organic light emitting diodes (OLED) often performed low efficiencies relative to pure phosphorescent OLED and could hardly be used to construct white OLED (WOLED). In this work, a new mechanism is developed to realize efficient WOLED with extremely simple structure by redistributing the energy of triplet exciplex to both singlet exciplex and the orange dopant. The micro process of energy transfer could be directly examined by detailed photoluminescence decay measurement and time resolved photoluminescence analysis. This strategy overcomes the low reverse intersystem crossing efficiency of blue exciplex and complicated device structure of traditional WOLED, enables us to achieve efficient hybrid WOLEDs. Based on this mechanism, we have successfully constructed both exciplex-fluorescence and exciplex-phosphorescence hybrid WOLEDs with remarkable efficiencies.
Zhang, Tianyou; Zhao, Bo; Chu, Bei; Li, Wenlian; Su, Zisheng; Yan, Xingwu; Liu, Chengyuan; Wu, Hairuo; Gao, Yuan; Jin, Fangming; Hou, Fuhua
2015-01-01
Exciplex is well known as a charge transfer state formed between electron-donating and electron-accepting molecules. However, exciplex based organic light emitting diodes (OLED) often performed low efficiencies relative to pure phosphorescent OLED and could hardly be used to construct white OLED (WOLED). In this work, a new mechanism is developed to realize efficient WOLED with extremely simple structure by redistributing the energy of triplet exciplex to both singlet exciplex and the orange dopant. The micro process of energy transfer could be directly examined by detailed photoluminescence decay measurement and time resolved photoluminescence analysis. This strategy overcomes the low reverse intersystem crossing efficiency of blue exciplex and complicated device structure of traditional WOLED, enables us to achieve efficient hybrid WOLEDs. Based on this mechanism, we have successfully constructed both exciplex-fluorescence and exciplex-phosphorescence hybrid WOLEDs with remarkable efficiencies. PMID:25975371
Homogeneous plate based antibody internalization assay using pH sensor fluorescent dye.
Nath, Nidhi; Godat, Becky; Zimprich, Chad; Dwight, Stephen J; Corona, Cesear; McDougall, Mark; Urh, Marjeta
2016-04-01
Receptor-mediated antibody internalization is a key mechanism underlying several anti-cancer antibody therapeutics. Delivering highly toxic drugs to cancer cells, as in the case of antibody drug conjugates (ADCs), efficient removal of surface receptors from cancer cells and changing the pharmacokinetics profile of the antibody drugs are some of key ways that internalization impacts the therapeutic efficacy of the antibodies. Over the years, several techniques have been used to study antibody internalization including radiolabels, fluorescent microscopy, flow cytometry and cellular toxicity assays. While these methods allow analysis of internalization, they have limitations including a multistep process and limited throughput and are generally endpoint assays. Here, we present a new homogeneous method that enables time and concentration dependent measurements of antibody internalization. The method uses a new hydrophilic and bright pH sensor dye (pHAb dye), which is not fluorescent at neutral pH but becomes highly fluorescent at acidic pH. For receptor mediated antibody internalization studies, antibodies against receptors are conjugated with the pHAb dye and incubated with the cells expressing the receptors. Upon binding to the receptor, the dyes conjugated to the antibody are not fluorescent because of the neutral pH of the media, but upon internalization and trafficking into endosomal and lysosomal vesicles the pH drops and dyes become fluorescent. The enabling attributes of the pHAb dyes are the hydrophilic nature to minimize antibody aggregation and bright fluorescence at acidic pH which allows development of simple plate based assays using a fluorescent reader. Using two different therapeutic antibodies--Trastuzumab (anti-HER2) and Cetuximab (anti-EGFR)--we show labeling with pHAb dye using amine and thiol chemistries and impact of chemistry and dye to antibody ration on internalization. We finally present two new approaches using the pHAb dye, which will be beneficial for screening a large number of antibody samples during early monoclonal development phase. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Schneider, Marilyn J
2008-08-01
A simple, rapid fluorescence screening assay was applied to the analysis of beef muscle for danofloxacin at the U.S. tolerance level of 200 ng/g. Muscle samples were homogenized in acetic acid-acetonitrile, the resultant mixture centrifuged, and fluorescence of the supernatants was then measured. The significant difference between the fluorescence of control muscle sample extracts and extracts of samples fortified at 200 ng/g allowed for successful discrimination between the samples. Setting a threshold level at the average 200 ng/g fortified sample extract fluorescence -3sigma allowed for identification of potentially violative samples. Successful analysis of a group of blind fortified samples over a range of concentrations was accomplished in this manner, without any false-negative results. The limits of quantitation for danofloxacin, as well as enrofloxacin, using this assay were determined in three types of beef muscle (hanging tenderloin, neck, and eye round steak), as well as in serum. Significant differences in limits of quantitation were found among the three different muscle types examined, with hanging tenderloin muscle providing the lowest value. This work not only shows the potential for use of the fluorescence screening assay as an alternative to currently used microbial or antibody-based assays for the analysis of danofloxacin in beef muscle, but also suggests that assays using beef muscle may vary in performance depending on the specific muscle selected for analysis.
A simple and sensitive high-throughput GFP screening in woody and herbaceous plants.
Hily, Jean-Michel; Liu, Zongrang
2009-03-01
Green fluorescent protein (GFP) has been used widely as a powerful bioluminescent reporter, but its visualization by existing methods in tissues or whole plants and its utilization for high-throughput screening remains challenging in many species. Here, we report a fluorescence image analyzer-based method for GFP detection and its utility for high-throughput screening of transformed plants. Of three detection methods tested, the Typhoon fluorescence scanner was able to detect GFP fluorescence in all Arabidopsis thaliana tissues and apple leaves, while regular fluorescence microscopy detected it only in Arabidopsis flowers and siliques but barely in the leaves of either Arabidopsis or apple. The hand-held UV illumination method failed in all tissues of both species. Additionally, the Typhoon imager was able to detect GFP fluorescence in both green and non-green tissues of Arabidopsis seedlings as well as in imbibed seeds, qualifying it as a high-throughput screening tool, which was further demonstrated by screening the seedlings of primary transformed T(0) seeds. Of the 30,000 germinating Arabidopsis seedlings screened, at least 69 GFP-positive lines were identified, accounting for an approximately 0.23% transformation efficiency. About 14,000 seedlings grown in 16 Petri plates could be screened within an hour, making the screening process significantly more efficient and robust than any other existing high-throughput screening method for transgenic plants.
Fluorescence imaging of angiogenesis in green fluorescent protein-expressing tumors
NASA Astrophysics Data System (ADS)
Yang, Meng; Baranov, Eugene; Jiang, Ping; Li, Xiao-Ming; Wang, Jin W.; Li, Lingna; Yagi, Shigeo; Moossa, A. R.; Hoffman, Robert M.
2002-05-01
The development of therapeutics for the control of tumor angiogenesis requires a simple, reliable in vivo assay for tumor-induced vascularization. For this purpose, we have adapted the orthotopic implantation model of angiogenesis by using human and rodent tumors genetically tagged with Aequorea victoria green fluorescent protein (GFP) for grafting into nude mice. Genetically-fluorescent tumors can be readily imaged in vivo. The non-luminous induced capillaries are clearly visible against the bright tumor fluorescence examined either intravitally or by whole-body luminance in real time. Fluorescence shadowing replaces the laborious histological techniques for determining blood vessel density. High-level GFP-expressing tumor cell lines made it possible to acquire the high-resolution real-time fluorescent optical images of angiogenesis in both primary tumors and their metastatic lesions in various human and rodent tumor models by means of a light-based imaging system. Intravital images of angiogenesis onset and development were acquired and quantified from a GFP- expressing orthotopically-growing human prostate tumor over a 19-day period. Whole-body optical imaging visualized vessel density increasing linearly over a 20-week period in orthotopically-growing, GFP-expressing human breast tumor MDA-MB-435. Vessels in an orthotopically-growing GFP- expressing Lewis lung carcinoma tumor were visualized through the chest wall via a reversible skin flap. These clinically-relevant angiogenesis mouse models can be used for real-time in vivo evaluation of agents inhibiting or promoting tumor angiogenesis in physiological micro- environments.
Pathiratne, A; Hemachandra, C K; Pathiratne, K A S
2010-05-01
Bile fluorescence patterns in Nile tilapia, a potential fish for biomonitoring tropical water pollution were assessed following exposure to selected polycyclic aromatic hydrocarbons (PAHs): naphthalene, phenanthrene, pyrene and chrysene. Non-normalized fixed wavelength fluorescence signals in the fish exposed to these PAHs reflected dose and/or time response relationships of their metabolism. Normalizing signals to biliverdin introduced deviations to these response patterns. The optimal wavelength pairs (excitation/emission) for synchronous fluorescence scanning measurements of bile metabolites of naphthalene, phenanthrene, pyrene and chrysene were identified as 284/326, 252/357, 340/382 and 273/382 respectively. This study supports the use of bile fluorescence in Nile tilapia by fixed wavelength fluorescence and synchronous fluorescence spectrometry with non-normalized data as a simple method for screening bioavailability of these PAHs.
Introducing a fluorescence-based standard to quantify protein partitioning into membranes.
Thomas, Franziska A; Visco, Ilaria; Petrášek, Zdeněk; Heinemann, Fabian; Schwille, Petra
2015-11-01
The affinity of peripheral membrane proteins for a lipid bilayer can be described using the partition coefficient (KP). Although several methods to determine KP are known, all possess limitations. To address some of these issues, we developed both: a versatile method based on single molecule detection and fluorescence imaging for determining KP, and a simple measurement standard employing hexahistidine-tagged enhanced green fluorescent protein (eGFP-His6) and free standing membranes of giant unilamellar vesicles (GUVs) functionalized with NTA(Ni) lipids as binding sites. To ensure intrinsic control, our method features two measurement modes. In the single molecule mode, fluorescence correlation spectroscopy (FCS) is applied to quantify free and membrane associated protein concentrations at equilibrium and calculate KP. In the imaging mode, confocal fluorescence images of GUVs are recorded and analyzed with semi-automated software to extract protein mean concentrations used to derive KP. Both modes were compared by determining the affinity of our standard, resulting in equivalent KP values. As observed in other systems, eGFP-His6 affinity for membranes containing increasing amounts of NTA(Ni) lipids rises in a stronger-than-linear fashion. We compared our dual approach with a FCS-based assay that uses large unilamellar vesicles (LUVs), which however fails to capture the stronger-than-linear trend for our NTA(Ni)-His6 standard. Hence, we determined the KP of the MARCKS effector domain with our FCS approach on GUVs, whose results are consistent with previously published data using LUVs. We finally provide a practical manual on how to measure KP and understand it in terms of molecules per lipid surface. Copyright © 2015. Published by Elsevier B.V.
Antigen detection based on background fluorescence quenching immunochromatographic assay.
Chen, Xiangjun; Xu, Yangyang; Yu, Jinsheng; Li, Jiutong; Zhou, Xuelei; Wu, Chuanyong; Ji, Qiuliang; Ren, Yuan; Wang, Liqun; Huang, Zhengyi; Zhuang, Hanling; Piao, Long; Head, Richard; Wang, Yajie; Lou, Jiatao
2014-09-02
Gold immunochromatographic assay (GICA) has been around for quite a while, but it is qualitative in the vast majority of applications. A fast, simple and quantitative GICA is in call for better medicine. In the current study, we have established a novel, quantitative GICA based on fluorescence quenching and nitrocellulose membrane background signals, called background fluorescence quenching immunochromatographic assay (bFQICA). Using model analyte alpha-fetoprotein (AFP), the present study assessed the performance of bFQICA in numerous assay aspects. With serial dilutions of the international AFP standard, standard curves for the calculation of AFP concentration were successfully established. At 10 and 100ngmL(-1) of the international AFP standard, the assay variability was defined with a coefficient of variance at 10.4% and 15.2%, respectively. For samples with extended range of AFP levels, bFQICA was able to detect AFP at as low as 1ngmL(-1). Fluorescence in bFQICA strips stayed constant over months. A good correlation between the results from bFQICA and from a well-established Roche electrochemiluminescence immunoassay was observed in 27 serum samples (r=0.98, p<0.001). In conclusion, our study has demonstrated distinctive features of bFQICA over conventional GICA, including utilization of a unique fluorescence ratio between nitrocellulose membrane background and specific signals (F1/F2) to ensure accurate measurements, combined qualitative and quantitative capabilities, and exceptionally high sensitivity for detection of very low levels of antigens. All of these features could make bFQICA attractive as a model for antigen-antibody complex based GICA, and could promote bFQICA to a broad range of applications for investigation of a variety of diseases. Copyright © 2014 Elsevier B.V. All rights reserved.
Highly Fluorescent Noble Metal Quantum Dots
Zheng, Jie; Nicovich, Philip R.; Dickson, Robert M.
2009-01-01
Highly fluorescent, water-soluble, few-atom noble metal quantum dots have been created that behave as multi-electron artificial atoms with discrete, size-tunable electronic transitions throughout the visible and near IR. These “molecular metals” exhibit highly polarizable transitions and scale in size according to the simple relation, Efermi/N1/3, predicted by the free electron model of metallic behavior. This simple scaling indicates that fluorescence arises from intraband transitions of free electrons and that these conduction electron transitions are the low number limit of the plasmon – the collective dipole oscillations occurring when a continuous density of states is reached. Providing the “missing link” between atomic and nanoparticle behavior in noble metals, these emissive, water-soluble Au nanoclusters open new opportunities for biological labels, energy transfer pairs, and light emitting sources in nanoscale optoelectronics. PMID:17105412
NASA Astrophysics Data System (ADS)
Karagodova, Tamara Y.
1999-03-01
The theory of resonant fluorescence of multilevel system in two monochromatic intense laser fields has been applied for investigating the temporal decay of magnetic sublevels of an atom. As for two-level system the triplet of resonant fluorescence is observed, for real atom being the multilevel system the multiplet of resonant fluorescence can be observed. The excitation spectra, defining the intensities of lines in the multiplet of resonant fluorescence, and shifts of components of spectra are shown. Typical temporal dependence of fluorescence intensity for magnetic sublevels of an atom having different relaxation constants is shown. The computer simulation of resonant fluorescence for simple systems can help to understand the regularities in temporal decay curves of atherosclerotic plaque, malignant tumor compared to normal surrounding tissue.
NASA Astrophysics Data System (ADS)
Tiwari, Karishma; Kumar, Sumit; Kumar, Vipan; Kaur, Jeevanjot; Arora, Saroj; Mahajan, Rakesh Kumar
2018-02-01
A simple and cost effective unsymmetrical azine based Schiff base, 5-diethylamino-2-[(2-hydroxy-benzylidene)hydrazonomethyl]-phenol (1) was synthesized which selectively detect Cu2 + ions in the presence of other competitive ions through ;naked eye; in physiological conditions (EtOH-buffer (1:1, v/v, HEPES 10 mM, pH = 7.4)). The presence of Cu2 + induce color change from light yellow green to yellow with the appearance of a new band at 450 nm in UV-Vis spectra of Schiff base 1. The fluorescence of Schiff base 1 (10 μM) was quenched completely in the presence of 2.7 equiv. of Cu2 + ions. Sub-micromolar limit of detection (LOD = 3.4 × 10- 7 M), efficient Stern-Volmer quenching constant (KSV = 1.8 × 105 L mol- 1) and strong binding constant (log Kb = 5.92) has been determined with the help of fluorescence titration profile. Further, 1 - Cu2 + complex was employed for the detection of phosphate ions (PO43 -, HPO42 - and H2PO4-) at micromolar concentrations in EtOH-buffer of pH 7.4 based on fluorescence recovery due to the binding of Cu2 + with phosphate ions. Solubility at low concentration in aqueous medium, longer excitation (406 nm) and emission wavelength (537 nm), and biocompatibility of Schiff base 1 formulates its use in live cell imaging.
Anazawa, Takashi; Yokoi, Takahide; Uchiho, Yuichi
2015-09-01
A simple and highly sensitive technique for laser-induced fluorescence detection on multiple channels in a plastic microchip was developed, and its effectiveness was demonstrated by laser-beam ray-trace simulations and experiments. In the microchip, with refractive index nC, A channels and B channels are arrayed alternately and respectively filled with materials with refractive indexes nA for electrophoresis analysis and nB for laser-beam control. It was shown that a laser beam entering from the side of the channel array traveled straight and irradiated all A channels simultaneously and effectively because the refractive actions by the A and B channels were counterbalanced according to the condition nA < nC < nB. This technique is thus called "side-entry laser-beam zigzag irradiation". As a demonstration of the technique, when nC = 1.53, nA = 1.41, nB = 1.66, and the cross sections of both eight A channels and seven B channels were the same isosceles trapezoids with 97° base angle, laser-beam irradiation efficiency on the eight A channels by the simulations was 89% on average and coefficient of variation was 4.4%. These results are far superior to those achieved by other conventional methods such as laser-beam expansion and scanning. Furthermore, fluorescence intensity on the eight A channels determined by the experiments agreed well with that determined by the simulations. Therefore, highly sensitive and uniform fluorescence detection on eight A channels was achieved. It is also possible to fabricate the microchips at low cost by plastic-injection molding and to make a simple and compact detection system, thereby promoting actual use of the proposed side-entry laser-beam zigzag irradiation in various fields.
Yurova, Nadezhda S; Danchuk, Alexandra; Mobarez, Sarah N; Wongkaew, Nongnoot; Rusanova, Tatiana; Baeumner, Antje J; Duerkop, Axel
2018-01-01
Electrospun nanofibers (ENFs) are promising materials for rapid diagnostic tests like lateral flow assays and dipsticks because they offer an immense surface area while excluding minimal volume, a variety of functional surface groups, and can entrap functional additives within their interior. Here, we show that ENFs on sample pads are superior in comparison to standard polymer membranes for the optical detection of biogenic amines (BAs) in food using a dipstick format. Specifically, cellulose acetate (CA) fibers doped with 2 mg/mL of the chromogenic and fluorogenic amine-reactive chameleon dye Py-1 were electrospun into uniform anionic mats. Those extract cationic BAs from real samples and Py-1 transduces BA concentrations into a change of color, reflectance, and fluorescence. Dropping a BA sample onto the nanofiber mat converts the weakly fluorescent pyrylium dye Py-1 into a strongly red emitting pyridinium dye. For the first time, a simple UV lamp excites fluorescence and a digital camera acts as detector. The intensity ratio of the red to the blue channel of the digital image is dependent on the concentration of most relevant BAs indicating food spoilage from 10 to 250 μM. This matches the permitted limits for BAs in foods and no false positive signals arise from secondary and tertiary amines. BA detection in seafood samples was also demonstrated successfully. The nanofiber mat dipsticks were up to sixfold more sensitive than those using a polymer membrane with the same dye embedded. Hence, nanofiber-based tests are not only superior to polymer-based dipstick assays, but will also improve the performance of established tests related to food safety, medical diagnostics, and environmental testing. Graphical Absract ᅟ.
NASA Astrophysics Data System (ADS)
Ruan, Shaobo; Qian, Jun; Shen, Shun; Zhu, Jianhua; Jiang, Xinguo; He, Qin; Gao, Huile
2014-08-01
Fluorescent carbon dots (CD) possess impressive potential in bioimaging because of their low photobleaching, absence of optical blinking and good biocompatibility. However, their relatively short excitation/emission wavelengths restrict their application in in vivo imaging. In the present study, a kind of CD was prepared by a simple heat treatment method using glycine as the only precursor. The diameter of CD was lower than 5 nm, and the highest emission wavelength was 500 nm. However, at 600 nm, there was still a relatively strong fluorescent emission, suggesting CD could be used for in vivo imaging. Additionally, several experiments demonstrated that CD possessed good serum stability and low cytotoxicity. In vitro, CD could be taken up into C6 glioma cells in a time- and concentration-dependent manner, with both endosomes and mitochondria involved. In vivo, CD could be used for non-invasive glioma imaging because of its high accumulation in the glioma site of the brain, which was demonstrated by both in vivo imaging and ex vivo tissue imaging. Furthermore, the fluorescent distribution in tissue slices also showed CD distributed in glioma with high intensity, while with a low intensity in normal brain tissue. In conclusion, CD were prepared using a simple method with relatively long excitation and emission wavelengths and could be used for non-invasive glioma imaging.Fluorescent carbon dots (CD) possess impressive potential in bioimaging because of their low photobleaching, absence of optical blinking and good biocompatibility. However, their relatively short excitation/emission wavelengths restrict their application in in vivo imaging. In the present study, a kind of CD was prepared by a simple heat treatment method using glycine as the only precursor. The diameter of CD was lower than 5 nm, and the highest emission wavelength was 500 nm. However, at 600 nm, there was still a relatively strong fluorescent emission, suggesting CD could be used for in vivo imaging. Additionally, several experiments demonstrated that CD possessed good serum stability and low cytotoxicity. In vitro, CD could be taken up into C6 glioma cells in a time- and concentration-dependent manner, with both endosomes and mitochondria involved. In vivo, CD could be used for non-invasive glioma imaging because of its high accumulation in the glioma site of the brain, which was demonstrated by both in vivo imaging and ex vivo tissue imaging. Furthermore, the fluorescent distribution in tissue slices also showed CD distributed in glioma with high intensity, while with a low intensity in normal brain tissue. In conclusion, CD were prepared using a simple method with relatively long excitation and emission wavelengths and could be used for non-invasive glioma imaging. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr02657h
Fan, Jiayun; Chang, Xingmao; He, Meixia; Shang, Congdi; Wang, Gang; Yin, Shiwei; Peng, Haonan; Fang, Yu
2016-07-20
Modification of naphthalene diimide (NDI) resulted in a photochemically stable, fluorescent 3,4,5-tris(dodecyloxy)benzamide derivative of NDI (TDBNDI), and introduction of the long alkyl chains endowed the compound with good compatibility with commonly found organic solvents and in particular superior self-assembly in the solution state. Further studies revealed that TDBNDI forms gels with nine of the 18 solvents tested at a concentration of 2.0% (w/v), and the critical gelation concentrations of five of the eight gels are lower than 1.0% (w/v), indicating the high efficiency of the compound as a low-molecular mass gelator (LMMG). Transmission electron microscopy, scanning electron microscopy, and confocal laser scanning microscopy studies revealed the networked fibrillar structure of the TDBNDI/methylcyclohexane (MCH) gel. On the basis of these findings, a fluorescent film was developed via simple spin-coating of the TDBNDI/MCH gel on a glass substrate surface. Fluorescence behavior and sensing performance studies demonstrated that this film is photochemically stable, and sensitive and selective to the presence of aniline vapor. Notably, the response is instantaneous, and the sensing process is fully and quickly reversible. This case study demonstrates that derivatization of photochemically stable fluorophores into LMMGs is a good strategy for developing high-performance fluorescent sensing films.
Nie, Hailiang; Jing, Jing; Tian, Yong; Yang, Wen; Zhang, Rubo; Zhang, Xiaoling
2016-04-13
Cellular self-regulation of reactive oxygen species (ROS) stress via glutathione (GSH) antioxidant repair plays a crucial role in maintaining redox balance, which affects various physiological and pathological pathways. In this work, we developed a simple yet effective strategy for reversible, dynamic, and real-time fluorescence imaging of ROS stress and GSH repair, based on novel Ge-pyronine dyes (GePs). Unlike the current O-pyronine (OP) dye, the fluorescence of GePs can be quenched in GSH reduction and then greatly restored by ROS (e.g., ClO(-), ONOO(-), and HO(•)) oxidation because of their unique affinity toward thiols. The "on-off" and "off-on" fluorescence switch can complete in 10 and 20 s, respectively, and exhibit excellent reversibility in vitro and in cells. GePs also show excitation in the long wavelength from the deep-red to near-infrared (NIR) (621-662 nm) region, high fluorescence quantum yield (Φ(fl) = 0.32-0.44) in aqueous media, and excellent cell permeability. Our results demonstrated that GePs can be used for real-time monitoring of the reversible and dynamic interconversion between ROS oxidation and GSH reduction in living cells. GePs might be a useful tool for investigating various redox-related physiological and pathological pathways.
Chen, Xiaochun; Yu, Shaoming; Yang, Liang; Wang, Jianping; Jiang, Changlong
2016-07-14
The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F(-) on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F(-) can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F(-) in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F(-) has been successfully developed. The paper sensor showed high sensitivity for aqueous F(-), and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes.
Thermal precipitation fluorescence assay for protein stability screening.
Fan, Junping; Huang, Bo; Wang, Xianping; Zhang, Xuejun C
2011-09-01
A simple and reliable method of protein stability assessment is desirable for high throughput expression screening of recombinant proteins. Here we described an assay termed thermal precipitation fluorescence (TPF) which can be used to compare thermal stabilities of recombinant protein samples directly from cell lysate supernatants. In this assay, target membrane proteins are expressed as recombinant fusions with a green fluorescence protein tag and solubilized with detergent, and the fluorescence signals are used to report the quantity of the fusion proteins in the soluble fraction of the cell lysate. After applying a heat shock, insoluble protein aggregates are removed by centrifugation. Subsequently, the amount of remaining protein in the supernatant is quantified by in-gel fluorescence analysis and compared to samples without a heat shock treatment. Over 60 recombinant membrane proteins from Escherichia coli were subject to this screening in the presence and absence of a few commonly used detergents, and the results were analyzed. Because no sophisticated protein purification is required, this TPF technique is suitable to high throughput expression screening of recombinant membrane proteins as well as soluble ones and can be used to prioritize target proteins based on their thermal stabilities for subsequent large scale expression and structural studies. Copyright © 2011 Elsevier Inc. All rights reserved.
Zhu, Desong; Wang, Lei; Xu, Xiaowen; Jiang, Wei
2016-01-15
Transcription factors (TFs) play pivotal roles in the regulation of a variety of essential cellular processes and some of them have been recognized as potential diagnostic markers and therapeutic targets of some diseases. Sensitive and accurate detection of TFs is of great importance to better understanding their roles in gene regulation and evaluation of disease state. Here, we developed a simple, label-free and enzyme-free new fluorescent strategy for the detection of TFs by graphene oxide (GO) fluorescence switch-based multifunctional G-quadruplex-hairpin probe (MGHP). The MGHP possessed of three functions simultaneously, adsorbing onto GO with the loop part, binding to target with the stem part and serving as signal carrier with the terminal G-quadruplex. First, the MGHP was adsorbed quickly to GO. Next, the TF bound to the stem part of MGHP to form a huge target-MGHP complex, which led to desorption of the complex from GO. Finally, NMM was inserted into G-quadruplex in the complex to yield an enhanced fluorescence response. The GO used here, as a fluorescence switch, could quickly and efficiently quench the fluorescence of NMM inserted into the MGHP absorbed on the GO, guaranteeing a high signal-to-noise ratio. Sensitive detection of purified NF-κB p50 and HeLa cell nuclear extracts were achieved with detection limits of 0.2nM and 7.8ng/µL, respectively. Moreover, this proposed strategy could be used to screen inhibitors of NF-κB p50 activity. The strategy proposed here might offer a new potential approach for reliable quantification of TFs in clinical diagnostics and treatment research of some diseases. Copyright © 2015 Elsevier B.V. All rights reserved.
Lu, Shuaimin; Li, Guoliang; Lv, Zhengxian; Qiu, Nannan; Kong, Weiheng; Gong, Peiwei; Chen, Guang; Xia, Lian; Guo, Xiaoxi; You, Jinmao; Wu, Yongning
2016-11-15
Early detection and diagnosis have great practical significances for the effective prevention and treatment of cancer. In this study, we developed a novel, facile and ultra-sensitive fluorescence assay for the determination of tumor invasive biomarker β-glucuronidase (GLU) based on the inner-filter effect (IFE). The nitrogen-doped carbon quantum dots (N-CQDs) with green photoluminescence were employed as the fluorophore in IFE, and 4-nitrophenyl-β-D-glucuronide (PNPG) was used to act as GLU substrate, and GLU catalytic product (p-nitrophenol (PNP)) was capable of acting as the robust absorber in IFE to turn off the fluorescence of N-CQDs due to the complementary overlap between the absorption of PNP and the excitation of N-CQDs. Thus, signal of GLU activity could be recorded by the fluorescence intensity of N-CQDs. Unlike other fluorescence sensing mechanism such as fluorescence resonance energy transfer (FRET) or photoinduced electron transfer (PET), IFE has no requirement for electron or energy transfer process or any chemical modification of fluorophore, which makes our assay more flexible and simple. The proposed method exhibited a good linear relationship from 1UL(-1) to 60UL(-1) (R(2)=0.9967) with a low detection limit of 0.3UL(-1). This method was also successfully applied to the analysis of serum samples and the inhibitor screening from natural product. The developed sensor platform was proven to be reliable, facile, sensitive, and selective, making it promising as a candidate for GLU activity detection in clinic tumor diagnose and anti-tumor drug screening. Copyright © 2016 Elsevier B.V. All rights reserved.
Droplet sorting based on the number of encapsulated particles using a solenoid valve.
Cao, Zhenning; Chen, Fangyuan; Bao, Ning; He, Huacheng; Xu, Peisheng; Jana, Saikat; Jung, Sunghwan; Lian, Hongzhen; Lu, Chang
2013-01-07
Droplet microfluidics provides a high-throughput platform for screening subjects and conditions involved in biology. Droplets with encapsulated beads and cells have been increasingly used for studying molecular and cellular biology. Droplet sorting is needed to isolate and analyze the subject of interest during such screening. The vast majority of current sorting techniques use fluorescence intensity emitted by each droplet as the only criterion. However, due to the randomness and imperfections in the encapsulation process, typically a mixed population of droplets with an uneven number of encapsulated particles results and is used for screening. Thus droplet sorting based on the number of encapsulated particles becomes necessary for isolating or enriching droplets with a specific occupancy. In this work, we developed a fluorescence-activated microfluidic droplet sorter that integrated a simple deflection mechanism based on the use of a solenoid valve and a sophisticated signal processing system with a microcontroller as the core. By passing droplets through a narrow interrogation channel, the encapsulated particles were detected individually. The microcontroller conducted the computation to determine the number of encapsulated particles in each droplet and made the sorting decision accordingly that led to actuation of the solenoid valve. We tested both fluorescent beads and stained cells and our results showed high efficiency and accuracy for sorting and enrichment.
Chen, Jinyang; Ji, Xinghu; Tinnefeld, Philip; He, Zhike
2016-01-27
In this work, a multifunctional template for selective formation of fluorescent silver nanoclusters (AgNCs) or copper nanoparticles (CuNPs) is put forward. This dumbbell-shaped (DS) DNA template is made up of two cytosine hairpin loops and an adenine-thymine-rich double-helical stem which is closed by the loops. The cytosine loops act as specific regions for the growth of AgNCs, and the double-helical stem serves as template for the CuNPs formation. By carefully investigating the sequence and length of DS DNA, we present the optimal design of the template. Benefiting from the smart design and facile synthesis, a simple, label-free, and ultrasensitive fluorescence strategy for adenosine triphosphate (ATP) detection is proposed. Through the systematic comparison, it is found that the strategy based on CuNPs formation is more sensitive for ATP assay than that based on AgNCs synthesis, and the detection limitation was found to be 81 pM. What's more, the CuNPs formation-based method is successfully applied in the detection of ATP in human serum as well as the determination of cellular ATP. In addition to small target molecule, the sensing strategy was also extended to the detection of biomacromolecule (DNA), which illustrates the generality of this biosensor.
NASA Astrophysics Data System (ADS)
Chen, Gaosong; Song, Jingjing; Zhang, Haoli; Jiang, Yuntian; Liu, Weisheng; Zhang, Wei; Wang, Baodui
2015-08-01
Rapid and simple molecular recognition based techniques for the identification of the subtypes of cancer cells are essential in molecular medicine. However, improving the sensitivity and accuracy of the early diagnosis of this disease remains a major challenge. Herein, we develop a novel approach for the in situ growth of palladium nanoparticles in magnetic carbon nanocages (PdNPs/MCNCs). The confined Pd NPs, which have excellent dispersion in magnetic carbon nanocages, show superior catalytic performance for the cleavage reaction of N-butyl-4-NHAlloc-1,8-naphthalimide (NNPH), thereby producing significant changes in both color (from colorless to jade-green) and fluorescence (from blue to green) through the ICT process. Based on the abovementioned results, a novel sensing platform utilizing the PdNPs/MCNC nanocatalyst as an artificial enzyme and NNPH as a fluorescent and color change reporter molecule for the multicolor imaging and colorimetric detection of cancer cells was developed. We envision that this nanomaterial can be used as a power tool for a wide range of potential applications in biotechnology and medicine.Rapid and simple molecular recognition based techniques for the identification of the subtypes of cancer cells are essential in molecular medicine. However, improving the sensitivity and accuracy of the early diagnosis of this disease remains a major challenge. Herein, we develop a novel approach for the in situ growth of palladium nanoparticles in magnetic carbon nanocages (PdNPs/MCNCs). The confined Pd NPs, which have excellent dispersion in magnetic carbon nanocages, show superior catalytic performance for the cleavage reaction of N-butyl-4-NHAlloc-1,8-naphthalimide (NNPH), thereby producing significant changes in both color (from colorless to jade-green) and fluorescence (from blue to green) through the ICT process. Based on the abovementioned results, a novel sensing platform utilizing the PdNPs/MCNC nanocatalyst as an artificial enzyme and NNPH as a fluorescent and color change reporter molecule for the multicolor imaging and colorimetric detection of cancer cells was developed. We envision that this nanomaterial can be used as a power tool for a wide range of potential applications in biotechnology and medicine. Electronic supplementary information (ESI) available: VSM, XRD, EDX, ESI-MS spectra, UV-vis and FT-IR spectra, 1H NMR spctra. See DOI: 10.1039/c5nr03421c
Cheng, Sheng; Zheng, Bin; Yao, Dongbao; Kuai, Shenglong; Tian, Jingjing; Liang, Haojun; Ding, Yunsheng
2018-06-11
Aptamers could be used to construct simple and effective biosensor because the conformational switch of aptamer upon target binding is easy to be transferred to optical or electrochemical signals. Nevertheless, we found that the binding between saxitoxin (STX) and aptamer (M-30f) is not accompanied with conformational switch. Here, the circular dichroism spectra, fluorophore and quencher labeled aptamer, and crystal violet-based assays were used to identify the binding way between STX and aptamer. The results show that the conformation of aptamer is stabilized in PBS buffer (10 mM phosphate buffer, 2.7 mM KCl, 137 mM NaCl, pH 7.4) and this conformation may provide an exactly suitable cave for STX binding. Through the analysis of UV-melting curves and circular dichroism-melting curves, it is found that different concentrations of STX produce different unfolding extents of the aptamer under high temperature. Then, a simple temperature-assisted "turn-on" fluorescent aptasensor was developed to detect STX and the application in real sample detection demonstrates its feasibility. The proposed method provides not only an alternative for STX detection but also a strategy for simple aptasensor design using aptamers that do not switch conformation upon targets binding. Copyright © 2018 Elsevier B.V. All rights reserved.
Ghanim, Murad; Brumin, Marina; Popovski, Smadar
2009-08-01
A simple, rapid, inexpensive method for the localization of virus transcripts in plant and insect vector tissues is reported here. The method based on fluorescent in situ hybridization using short DNA oligonucleotides complementary to an RNA segment representing a virus transcript in the infected plant or insect vector. The DNA probe harbors a fluorescent molecule at its 5' or 3' ends. The protocol: simple fixation, hybridization, minimal washing and confocal microscopy, provides a highly specific signal. The reliability of the protocol was tested by localizing two phloem-limited plant virus transcripts in infected plants and insect tissues: Tomato yellow leaf curl virus (TYLCV) (Begomovirus: Geminiviridae), exclusively transmitted by the whitefly Bemisia tabaci (Gennadius) in a circulative non-propagative manner, and Potato leafroll virus (Polerovirus: Luteoviridae), similarly transmitted by the aphid Myzus persicae (Sulzer). Transcripts for both viruses were localized specifically to the phloem sieve elements of infected plants, while negative controls showed no signal. TYLCV transcripts were also localized to the digestive tract of B. tabaci, confirming TYLCV route of transmission. Compared to previous methods for localizing virus transcripts in plant and insect tissues that include complex steps for in-vitro probe preparation or antibody raising, tissue fixation, block preparation, sectioning and hybridization, the method described below provides very reliable, convincing, background-free results with much less time, effort and cost.
In vivo assessment of wound re-epithelialization by UV fluorescence excitation imaging
NASA Astrophysics Data System (ADS)
Wang, Ying; Ortega-Martinez, Antonio; Padilla-Martinez, Juan Pablo; Williams, Maura; Farinelli, William; Anderson, R. R.; Franco, Walfre
2017-02-01
Background and Objectives: We have previously demonstrated the efficacy of a non-invasive, non-contact, fast and simple but robust fluorescence imaging (u-FEI) method to monitor the healing of skin wounds in vitro. This system can image highly-proliferating cellular processes (295/340 nm excitation/emission wavelengths) to study epithelialization in a cultured wound model. The objective of the current work is to evaluate the suitability of u-FEI for monitoring wound re-epithelialization in vivo. Study Design: Full-thickness wounds were created in the tail of rats and imaged weekly using u-FEI at 295/340nm excitation/emission wavelengths. Histology was used to investigate the correlation between the spatial distribution and intensity of fluorescence and the extent of wound epithelialization. In addition, the expression of the nuclear protein Ki67 was used to confirm the association between the proliferation of keratinocyte cells and the intensity of fluorescence. Results: Keratinocytes forming neo-epidermis exhibited higher fluorescence intensity than the keratinocytes not involved in re-epithelialization. In full-thickness wounds the fluorescence first appeared at the wound edge where keratinocytes initiated the epithelialization process. Fluorescence intensity increased towards the center as the keratinocytes partially covered the wound. As the wound healed, fluorescence decreased at the edges and was present only at the center as the keratinocytes completely covered the wound at day 21. Histology demonstrated that changes in fluorescence intensity from the 295/340nm band corresponded to newly formed epidermis. Conclusions: u-FEI at 295/340nm allows visualization of proliferating keratinocyte cells during re-epithelialization of wounds in vivo, potentially providing a quantitative, objective and simple method for evaluating wound closure in the clinic.
A simple tagging system for protein encapsulation.
Seebeck, Florian P; Woycechowsky, Kenneth J; Zhuang, Wei; Rabe, Jürgen P; Hilvert, Donald
2006-04-12
Molecular containers that encapsulate specific cargo can be useful for many natural and non-natural processes. We report a simple system, based on charge complementarity, for the encapsulation of appropriately tagged proteins within an engineered, proteinaceous capsid. Four negative charges per monomer were added to the lumazine synthase from Aquifex aeolicus (AaLS). The capsids formed by the engineered AaLS associate with green fluorescent protein bearing a positively charged deca-arginine tag upon coproduction in Escherichia coli. Analytical ultracentrifugation and scanning force microscopy studies indicated that the engineered AaLS retains the ability to form capsids, but that their average size was substantially increased. The success of this strategy demonstrates that both the container and guest components of protein-based encapsulation systems can be convergently designed in a straightforward manner, which may help to extend their versatility.
Anmei, Su; Qingmei, Zhong; Yuye, Chen; Yilin, Wang
2018-09-06
Carbon quantum dots (CQDs) with quantum yield of 14% were successfully synthesized via a simple, low-cost, and green hydrothermal treatment using cigarette filters as carbon source for the first time. The obtained CQDs showed a strong emission at the wavelength of 465 nm, with an optimum excitation of 365 nm.Sudan I with maximum absorption wavelength at 477 nm could selectively quench the fluorescence of CQDs. Based on this principle, a fluorescence probe was developed for Sudan I determination. Furthermore, the quenching mechanism of the CQDs was elucidated. A linear relationship was found in the range of 2.40-104.0 μmol/L Sudan I with the detection limit (3σ/k) of 0.95 μmol/L. Satisfactory results were achieved when the method was submitted to the determination of Sudan I in food samples. Copyright © 2018 Elsevier B.V. All rights reserved.
A NBD-based simple but effective fluorescent pH probe for imaging of lysosomes in living cells.
Cao, Xiang-Jian; Chen, Li-Na; Zhang, Xuan; Liu, Jin-Ting; Chen, Ming-Yu; Wu, Qiu-Rong; Miao, Jun-Ying; Zhao, Bao-Xiang
2016-05-12
NBDlyso with lysosome-locating morpholine moiety has been developed as a high selective and sensitive fluorescent pH probe. This probe can respond to acidic pH (2.0-7.0) in a short time (less than 1 min) and not almost change after continuously illuminated for an extended period by ultraviolet light. The fluorescence intensity of NBDlyso enhanced 100-fold in acidic solution, with very good linear relationship (R(2) = 0.996). The pKa of probe NBDlyso is 4.10. Therefore, NBDlyso was used to detect lysosomal pH changes successfully. Besides, X-ray crystallography was used to verify the structure of NBDlyso, and the recognition mechanism involving photo-induced electron transfer was interpreted theoretically by means of DFT and TDDFT calculations skillfully when NBDlyso comes into play under the acidic condition. This probe showed good ability to sense pH change in living cell image. Copyright © 2016 Elsevier B.V. All rights reserved.
Fluorescent sensors reporting the activity of ammonium transceptors in live cells
De Michele, Roberto; Ast, Cindy; Loqué, Dominique; ...
2013-07-02
Ammonium serves as key nitrogen source and metabolic intermediate, yet excess causes toxicity. Ammonium uptake is mediated by ammonium transporters, whose regulation is poorly understood. While transport can easily be characterized in heterologous systems, measuring transporter activity in vivo remains challenging. Here we developed a simple assay for monitoring activity in vivo by inserting circularly-permutated GFP into conformation-sensitive positions of two plant and one yeast ammonium transceptors (‘AmTrac’ and ‘MepTrac’). Addition of ammonium to yeast cells expressing the sensors triggered concentration-dependent fluorescence intensity (FI) changes that strictly correlated with the activity of the transporter. Fluorescence-based activity sensors present a novelmore » technology for monitoring the interaction of the transporters with their substrates, the activity of transporters and their regulation in vivo, which is particularly valuable in the context of analytes for which no radiotracers exist, as well as for cell-specific and subcellular transport processes that are otherwise difficult to track.« less
Peng, Guilong; Chen, Yi; Deng, Ruoyu; He, Qiang; Liu, Dun; Lu, Ying; Lin, Jin-Ming
2018-06-07
In this study, a convenient, sensitive, rapid and simple method was developed on microfluidic chip which was integrated with on-line complexing and laser-induced fluorescence detection. A rhodamine derivative (RD) was developed as a fluorescent chemosensor for Hg(II). It exhibited high selective recognition toward Hg(II) over other examined metal ions in water samples. Under the optimized conditions, the response was linearly proportional to the concentration of Hg(II) in the range of 0-70 μM with a detection limit of 0.031 μM. Satisfactory repeatability and reproducibility were achieved, with a relative standard deviation (RSD) of 6.62%. The established method was successfully applied for the determination of Hg(II) in environmental water samples (surface water, tap water, and waste water). Recoveries obtained for the determination of Hg(II) in spiking samples ranged from 85% to 103%. Copyright © 2018. Published by Elsevier B.V.
Poláček, Roman; Májek, Pavel; Hroboňová, Katarína; Sádecká, Jana
2016-04-01
Fluoxetine is the most prescribed antidepressant chiral drug worldwide. Its enantiomers have a different duration of serotonin inhibition. A novel simple and rapid method for determination of the enantiomeric composition of fluoxetine in pharmaceutical pills is presented. Specifically, emission, excitation, and synchronous fluorescence techniques were employed to obtain the spectral data, which with multivariate calibration methods, namely, principal component regression (PCR) and partial least square (PLS), were investigated. The chiral recognition of fluoxetine enantiomers in the presence of β-cyclodextrin was based on diastereomeric complexes. The results of the multivariate calibration modeling indicated good prediction abilities. The obtained results for tablets were compared with those from chiral HPLC and no significant differences are shown by Fisher's (F) test and Student's t-test. The smallest residuals between reference or nominal values and predicted values were achieved by multivariate calibration of synchronous fluorescence spectral data. This conclusion is supported by calculated values of the figure of merit.
Correlative super-resolution fluorescence microscopy combined with optical coherence microscopy
NASA Astrophysics Data System (ADS)
Kim, Sungho; Kim, Gyeong Tae; Jang, Soohyun; Shim, Sang-Hee; Bae, Sung Chul
2015-03-01
Recent development of super-resolution fluorescence imaging technique such as stochastic optical reconstruction microscopy (STORM) and photoactived localization microscope (PALM) has brought us beyond the diffraction limits. It allows numerous opportunities in biology because vast amount of formerly obscured molecular structures, due to lack of spatial resolution, now can be directly observed. A drawback of fluorescence imaging, however, is that it lacks complete structural information. For this reason, we have developed a super-resolution multimodal imaging system based on STORM and full-field optical coherence microscopy (FF-OCM). FF-OCM is a type of interferometry systems based on a broadband light source and a bulk Michelson interferometer, which provides label-free and non-invasive visualization of biological samples. The integration between the two systems is simple because both systems use a wide-field illumination scheme and a conventional microscope. This combined imaging system gives us both functional information at a molecular level (~20nm) and structural information at the sub-cellular level (~1μm). For thick samples such as tissue slices, while FF-OCM is readily capable of imaging the 3D architecture, STORM suffer from aberrations and high background fluorescence that substantially degrade the resolution. In order to correct the aberrations in thick tissues, we employed an adaptive optics system in the detection path of the STORM microscope. We used our multimodal system to obtain images on brain tissue samples with structural and functional information.
Chien, Miao-Ping; Werley, Christopher A.; Farhi, Samouil L.
2015-01-01
Sorting of target cells from a heterogeneous pool is technically difficult when the selection criterion is complex, e.g. a dynamic response, a morphological feature, or a combination of multiple parameters. At present, mammalian cell selections are typically performed either via static fluorescence (e.g. fluorescence activated cell sorter), via survival (e.g. antibiotic resistance), or via serial operations (flow cytometry, laser capture microdissection). Here we present a simple protocol for selecting cells based on any static or dynamic property that can be identified by video microscopy and image processing. The “photostick” technique uses a cell-impermeant photochemical crosslinker and digital micromirror array-based patterned illumination to immobilize selected cells on the culture dish. Other cells are washed away with mild protease treatment. The crosslinker also labels the selected cells with a fluorescent dye and a biotin for later identification. The photostick protocol preserves cell viability, permits genetic profiling of selected cells, and can be performed with complex functional selection criteria such as neuronal firing patterns. PMID:25705368
NASA Astrophysics Data System (ADS)
Li, Shaoyuan; Chen, Xiuhua; Ma, Wenhui; Ding, Zhao; Zhang, Cong; Chen, Zhengjie; He, Xiao; Shang, Yudong; Zou, Yuxin
2016-11-01
Developing an innovative “Test Paper” based on virgin nanoporous silicon (NPSi) which shows intense visible emission and excellent fluorescence stability. The visual fluorescence quenching “Test Paper” was highly selective and sensitive recognizing Cu2+ at μmol/L level. Within the concentration range of 5 × 10-7 ~50 × 10-7mol/L, the linear regression equation of IPL = 1226.3-13.6[CCu2+] (R = 0.99) was established for Cu2+ quantitative detection. And finally, Cu2+ fluorescence quenching mechanism of NPSi prober was proposed by studying the surface chemistry change of NPSi and metal ions immersed-NPSi using XPS characterization. The results indicate that SiHx species obviously contribute to the PL emission of NPSi, and the introduce of oxidization state and the nonradiative recombination center are responsible for the PL quenching. These results demonstrate how virgin NPSi wafer can serve as Cu2+ sensor. This work is of great significant to promote the development of simple instruments that could realize rapid, visible and real-time detection of various toxic metal ions.
NASA Astrophysics Data System (ADS)
Zhang, Wenzhi; Jin, Jiangjiang; Huang, Zhi; Zhuang, Shaoqing; Wang, Lei
2016-07-01
Thermally activated delayed fluorescence (TADF) mechanism is a significant method that enables the harvesting of both triplet and singlet excitons for emission. However, up to now most efforts have been devoted to dealing with the relation between singlet-triplet splitting (ΔEST) and fluorescence efficiency, while the significance of spin-orbit coupling (SOC) is usually ignored. In this contribution, a new method is developed to realize high-efficiency TADF-based devices through simple device-structure optimizations. By inserting an ultrathin external heavy-atom (EHA) perturber layer in a desired manner, it provides useful means of accelerating the T1 → S1 reverse intersystem crossing (RISC) in TADF molecules without affecting the corresponding S1 → T1 process heavily. Furthermore, this strategy also promotes the utilization of host triplets through Förster mechanism during host → guest energy transfer (ET) processes, which helps to get rid of the solely dependence upon Dexter mechanism. Based on this strategy, we have successfully raised the external quantum efficiency (EQE) in 4CzPN-based devices by nearly 38% in comparison to control devices. These findings provide keen insights into the role of EHA played in TADF-based devices, offering valuable guidelines for utilizing certain TADF dyes which possess high radiative transition rate but relatively inefficient RISC.
Determination of mutated genes in the presence of wild-type DNA by using molecular beacons as probe
NASA Astrophysics Data System (ADS)
Zhang, Yonghua; Ai, Junjie; Gu, Qiaorong; Gao, Qiang; Qi, Honglan; Zhang, Chengxiao
2017-03-01
Low-abundance mutations in the presence of wild-type DNA can be determined using molecular beacon (MB) as probe. A MB is generally used as DNA probe because it can distinguish single-base mismatched target DNA from fully matched target DNA. However, the probe can not determine low-abundance mutations in the presence of wild-type DNA. In this study, this limitation is addressed by enhancing the stability of unpaired base-containing dsDNA with a hydrogen-bonding ligand, which was added after hybridization of the MB to the target DNA. The ligand formed hydrogen bonds with unpaired bases and stabilized the unpaired base-containing dsDNA if target DNA is mutated one. As a result, more MBs were opened by the mutant genes in the presence of the ligand and a further increase in the fluorescence intensity was obtained. By contrast, fluorescence intensity did not change if target DNA is wild-type one. Consequent increase in the fluorescence intensity of the MB was regarded as a signal derived from mutant genes. The proposed method was applied in synthetic template systems to determine point mutation in DNA obtained from PCR analysis. The method also allows rapid and simple discrimination of a signal if it is originated in the presence of mutant gene or alternatively by a lower concentration of wild gene.
Why do aged fluorescent tubes flicker?
NASA Astrophysics Data System (ADS)
Plihon, Nicolas; Ferrand, Jérémy; Guyomar, Tristan; Museur, Flavien; Taberlet, Nicolas
2017-11-01
Our everyday experience of aged and defective fluorescent tubes or bulbs informs us that they may flicker and emit a clicking sound while struggling to light up. In this article, the physical mechanisms controlling the initial illumination of a functioning fluorescent tube are investigated using a simple and affordable experimental setup. Thermionic emission from the electrodes of the tube controls the startup of fluorescent tubes. The origin of the faulty startup of aged fluorescent tubes is discussed and flickering regimes using functional tubes are artificially produced using a dedicated setup that decreases electron emission by the thermionic effect in a controlled manner. The physical parameters controlling the occurrence of flickering light are discussed, and their temporal statistics are reported.
Han, Sung-Ho; Farshchi-Heydari, Salman; Hall, David J
2010-01-20
A novel time-domain optical method to reconstruct the relative concentration, lifetime, and depth of a fluorescent inclusion is described. We establish an analytical method for the estimations of these parameters for a localized fluorescent object directly from the simple evaluations of continuous wave intensity, exponential decay, and temporal position of the maximum of the fluorescence temporal point-spread function. Since the more complex full inversion process is not involved, this method permits a robust and fast processing in exploring the properties of a fluorescent inclusion. This method is confirmed by in vitro and in vivo experiments. Copyright 2010 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Signal improvement in multiphoton microscopy by reflection with simple mirrors near the sample
NASA Astrophysics Data System (ADS)
Rehberg, Markus; Krombach, Fritz; Pohl, Ulrich; Dietzel, Steffen
2010-03-01
In conventional fluorescence or confocal microscopy, emitted light is generated not only in the focal plane but also above and below. The situation is different in multiphoton-induced fluorescence and multiphoton-induced higher harmonic generation. Here, restriction of signal generation to a single focal point permits that all emitted photons can contribute to image formation if collected, regardless of their path through the specimen. Often, the intensity of the emitted light is rather low in biological specimens. We present a method to significantly increase the fraction of photons collected by an epi (backward) detector by placing a simple mirror, an aluminum-coated coverslip, directly under the sample. Samples investigated include fluorescent test slides, collagen gels, and thin-layered, intact mouse skeletal muscles. Quantitative analysis revealed an intensity increase of second- and third-harmonic generated signal in skeletal muscle of nine- and sevenfold respectively, and of fluorescent signal in test slides of up to twofold. Our approach thus allows significant signal improvement also for situations were a forward detection is impossible, e.g., due to the anatomy of animals in intravital microscopy.
Wang, Xiaoyan; Yu, Jialuo; Wu, Xiaqing; Fu, Junqing; Kang, Qi; Shen, Dazhong; Li, Jinhua; Chen, Lingxin
2016-07-15
A novel molecular imprinting-based turn-on ratiometric fluorescence sensor was constructed via a facile sol-gel polymerization for detection of 2,4-dichlorophenoxyacetic acid (2,4-D) on the basis of photoinduced electron transfer (PET) by using nitrobenzoxadiazole (NBD) as detection signal source and quantum dots (QDs) as reference signal source. With the presence and increase of 2,4-D, the amine groups on the surface of QDs@SiO2 could bind with 2,4-D and thereby the NBD fluorescence intensities could be significantly enhanced since the PET process was inhibited, while the QDs maintained constant intensities. Accordingly, the ratio of the dual-emission intensities of green NBD and red QDs could be utilized for turn-on fluorescent detection of 2,4-D, along with continuous color changes from orange-red to green readily observed by the naked eye. The as-prepared fluorescence sensor obtained high sensitivity with a low detection limit of 0.14μM within 5min, and distinguished recognition selectivity for 2,4-D over its analogs. Moreover, the sensor was successfully applied to determine 2,4-D in real water samples, and high recoveries at three spiking levels of 2,4-D ranged from 95.0% to 110.1% with precisions below 4.5%. The simple, rapid and reliable visual sensing strategy would not only provide potential applications for high selective ultratrace analysis of complicated matrices, but also greatly enrich the research connotations of molecularly imprinted sensors. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kim, Hye Jin; Kang, Dong-Hoon; Lee, Eunji; Hwang, Kyo Seon; Shin, Hyun-Joon; Kim, Jinsik
2018-02-01
We propose a simple fluorescent bio-chip based on two types of alternative current-dielectrophoretic (AC-DEP) force, attractive (positive DEP) and repulsive (negative DEP) force, for simultaneous nano-molecules analysis. Various radius of micro-holes on the bio-chip are designed to apply the different AC-DEP forces, and the nano-molecules are concentrated inside the micro-hole arrays according to the intensity of the DEP force. The bio-chip was fabricated by Micro Electro Mechanical system (MEMS) technique, and was composed of two layers; a SiO2 layer and Ta/Pt layer were accomplished for an insulation layer and a top electrode with micro-hole arrays to apply electric fields for DEP force, respectively. Each SiO2 and Ta/Pt layers were deposited by thermal oxidation and sputtering, and micro-hole arrays were fabricated with Inductively Coupled Plasma (ICP) etching process. For generation of each positive and negative DEP at micro-holes, we applied two types of sine-wave AC voltage with different frequency range alternately. The intensity of the DEP force was controlled by the radius of the micro-hole and size of nano-molecule, and calculated with COMSOL multi-physics. Three types of nano-molecules labelled with different fluorescent dye were used and the intensity of nano-molecules was examined by the fluorescent optical analysis after applying the DEP force. By analyzing the fluorescent intensities of the nano-molecules, we verify the various nano-molecules in analyte are located successfully inside corresponding micro-holes with different radius according to their size.
NASA Astrophysics Data System (ADS)
Gao, Feng; Han, Jiaxing; Lv, Caifeng; Wang, Qin; Zhang, Jun; Li, Qun; Bao, Liru; Li, Xin
2012-10-01
Fingerprint detection is important in criminal investigation. This paper reports a facile powder brushing technique for improving latent fingerprint detection using core-shell-structured CdTe@SiO2 quantum dots (QDs) as fluorescent labeling marks. Core-shell-structured CdTe@SiO2 QDs are prepared via a simple solution-based approach using NH2NH2·H2O as pH adjustor and stabilizer, and their application for improving latent fingerprint detection is explored. The obtained CdTe@SiO2 QDs show spherical shapes with well-defined core-shell structures encapsulating different amounts of QDs depending on the type of the pH adjustor and stabilizer. Moreover, the fluorescence of CdTe@SiO2 QDs is largely enhanced by surface modification of the SiO2 shell. The CdTe@SiO2 QDs overcome the oxidation problem of pure CdTe QDs in air, thus affording better variability with strong adhesive ability, better resolution, and bright emission colors for practical application in latent fingerprint detection. In comparison with the conventional fluorescence powders, silver powders, and others, the effectiveness of CdTe@SiO2 QD powders for detection of latent fingerprints present on a large variety of object surfaces is greatly improved. The synthesis method for CdTe@SiO2 QDs is simple, cheap, and easy for large-scale production, and thus offers many advantages in the practical application of fingerprint detection.
Gbaj, A; Bichenkova, EV; Walsh, L; Savage, HE; Sardarian, AR; Etchells, LL; Gulati, A; Hawisa, S; Douglas, KT
2009-01-01
The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5′-bispyrene and 3′-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5′-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5′-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing. PMID:21483539
NASA Astrophysics Data System (ADS)
Pratavieira, S.; Santos, P. L. A.; Bagnato, V. S.; Kurachi, C.
2009-06-01
Oral and skin cancers constitute a major global health problem that cause great impact in patients. The most common screening method for oral cancer is visual inspection and palpation of the mouth. Visual examination relies heavily on the experience and skills of the physician to identify and delineate early premalignant and cancer changes, which is not simple due to the similar characteristics of early stage cancers and benign lesions. Optical imaging has the potential to address these clinical challenges. Contrast between normal and neoplastic areas may be increased, distinct to the conventional white light, when using illumination and detection conditions. Reflectance imaging can detect local changes in tissue scattering and absorption and fluorescence imaging can probe changes in the biochemical composition. These changes have shown to be indicatives of malignant progression. Widefield optical imaging systems are interesting because they may enhance the screening ability in large regions allowing the discrimination and the delineation of neoplastic and potentially of occult lesions. Digital image processing allows the combination of autofluorescence and reflectance images in order to objectively identify and delineate the peripheral extent of neoplastic lesions in the skin and oral cavity. Combining information from different imaging modalities has the potential of increasing diagnostic performance, due to distinct provided information. A simple widefiled imaging device based on fluorescence and reflectance modes together with a digital image processing was assembled and its performance tested in an animal study.
Mohamed, Abdel-Maaboud I; Omar, Mahmoud A; Hammad, Mohamed A; Mohamed, Abobakr A
2016-11-01
A highly sensitive and simple spectrofluorimetric method was developed for the determination of Amlodipine besylate (AML) in its pharmaceutical formulations and spiked human plasma. The proposed method is based on the investigation of the fluorescence spectral behaviour of AML in Tween-80 micellar system. In aqueous solution, the fluorescence intensity of AML was greatly enhanced (160 %) in the presence of Tween-80. The fluorescence intensity was measured at 427 nm after excitation at 385 nm. The fluorescence-concentration plot was rectilinear over the concentration range 0.1-4.0 μg/ml, with lower detection limit of 0.03 μg/ml. The suggested method was successfully applied for the analysis of AML in its commercial tablets alone or in combination with either Atorvastatin or Valsartan. The application of the proposed method was extended to the assay of AML in spiked human plasma and stability studies of AML after exposure to different forced degradation conditions, such as acidic, alkaline, photo- and oxidative conditions, according to ICH guidelines. The results were statistically compared to those obtained by comparison methods and were found to be in good agreement.
NASA Astrophysics Data System (ADS)
Wu, Jian; Li, Bao-Hong; Zhong, Hua-Rui; Qiu, Shuo-Wen; Liang, Yi-Wen; Zhuang, Xiao-Yi; Singh, Amita; Kumar, Abhinav
2018-04-01
A biocompatible metal-organic framework (MOF) [Zn2(TPL)(FA)(OH)(H2O)] (1) (TPL = theophylline and H2FA = fumaric acid) had been chosen which offers an ideal model for the development of fluorescencent chemosensor using simple synthetic protocol. The MOF 1 have been tested as a fluorescent chemosensor against nitro-aromatics (NACs) and it displayed high selectivity for 4-NT over other NACs as evident by the emission spectroscopy. The alleviation in fluorescence intensity of 1 in presence of different NACs have been explained with the help of theoretical calculations which suggested that there is occurrence of both electron and energy transfer processes, in addition to electrostatic interaction between 1 and NACs which may be responsible for the unprecedented selective alleviation in the fluorescence intensity. Also, 1 had been deployed as a photocatalyst for the degradation of methyl violet (MV) and Rhodamine B (Rh B) in aqueous solution under UV irradiation. The photocatalytic results indicated the 1 exhibit 85% photocatalytic efficiency against Rh B in 100 min, while its efficiency against MV was only 50% under the identical experimental conditions. The possible mechanism for the photocatalytic activity has been proposed using density of states (DOS) calculations.
Hofmann, Oliver; Wang, Xuhua; Demello, John C; Bradley, Donal D C; Demello, Andrew J
2005-08-01
As a first step towards a fully disposable stand-alone diagnostic microchip for determination of urinary human serum albumin (HSA), we report the use of a thin-film organic light emitting diode (OLED) as an excitation source for microscale fluorescence detection. The OLED has a peak emission wavelength of 540 nm, is simple to fabricate on flexible or rigid substrates, and operates at drive voltages below 10 V. In a fluorescence assay, HSA is reacted with Albumin Blue 580, generating a strong emission at 620 nm when excited with the OLED. Filter-less discrimination between excitation light and generated fluorescence is achieved through an orthogonal detection geometry. When the assay is performed in 800 microm deep and 800 microm wide microchannels on a poly(dimethylsiloxane)(PDMS) microchip at flow rates of 20 microL min(-1), HSA concentrations down to 10 mg L(-1) can be detected with a linear range from 10 to 100 mg L(-1). This sensitivity is sufficient for the determination of microalbuminuria (MAU), an increased urinary albumin excretion indicative of renal disease (clinical cut-off levels: 15-40 mg L(-1)).
Zhang, Ya-Min; Shi, Rui; Hou, Jian-Cun; Liu, Zi-Rong; Cui, Zi-Lin; Li, Yang; Wu, Di; Shi, Yuan; Shen, Zhong-Yang
2017-01-01
Clear delineation between tumors and normal tissues is ideal for real-time surgical navigation imaging. We investigated applying indocyanine green (ICG) fluorescence imaging navigation using an intraoperative administration method in liver resection. Fifty patients who underwent liver resection were divided into two groups based on clinical situation and operative purpose. In group I, sizes of superficial liver tumors were determined; tiny tumors were identified. In group II, the liver resection margin was determined; real-time navigation was performed. ICG was injected intravenously at the beginning of the operation; the liver surface was observed with a photodynamic eye (PDE). Liver resection margins were determined using PDE. Fluorescence contrast between normal liver and tumor tissues was obvious in 32 of 35 patients. A boundary for half the liver or specific liver segments was determined in nine patients by examining the portal vein anatomy after ICG injection. Eight small tumors not observed preoperatively were detected; the smallest was 2 mm. ICG fluorescence imaging navigation is a promising, simple, and safe tool for routine real-time intraoperative imaging during hepatic resection and clinical exploration in hepatocellular carcinoma, enabling high sensibility for identifying liver resection margins and detecting tiny superficial tumors.
Fluorescent and colorimetric detection of Fe(III) and Cu(II) by a difunctional rhodamine-based probe
NASA Astrophysics Data System (ADS)
Wang, Lei; Ye, Dandan; Li, Wenxuan; Liu, Yuanyuan; Li, Longhua; Zhang, Wenli; Ni, Liang
2017-08-01
A new rhodamine B hydrazone derivative (probe L) was synthesized and characterized. The probe L had sufficiently satisfactory selective response to Fe3 + and Cu2 + ions among various interferential metal ions, and high sensitivity with the detection limit of 4.63 × 10- 9 M and 5.264 × 10- 7 M for Fe3 + and Cu2 + ions, respectively. In the presence of Fe3 +, the probe L exhibited turn-on orange fluorescence accompanied by color change from colorless to pink. Toward Cu2 +, the probe L showed significant color change from colorless to red purple. These remarkable orange fluorescence and color change made probe L suitable naked-eye identify for Fe3 + and Cu2 + ions. By means of Job's plot, Benesi-Hildebrand studies and FTIR spectra, both 1:1 binding modes (L-Fe3 + and L-Cu2 +) were confirmed. The coordination mechanism and turn on/off fluorescence for L-Fe3 + and L-Cu2 + complexes were well explained by theoretical calculations. Moreover, probe L could be used as a quick, simple, visual test strip for Fe3 + and Cu2 + detection.
Liu, Rui; Li, Wei; Cai, Tingting; Deng, Yang; Ding, Zhi; Liu, Yan; Zhu, Xuerui; Wang, Xin; Liu, Jie; Liang, Baowen; Zheng, Tiesong; Li, Jianlin
2018-05-02
A new aptamer microarray method on the TiO 2 -porous silicon (PSi) surface was developed to simultaneously screen multiplex mycotoxins. The TiO 2 nanolayer on the surface of PSi can enhance the fluorescence intensity 14 times than that of the thermally oxidized PSi. The aptamer fluorescence signal recovery principle was performed on the TiO 2 -PSi surface by hybridization duplex strand DNA from the mycotoxin aptamer and antiaptamer, respectively, labeled with fluorescence dye and quencher. The aptamer microarray can simultaneously screen for multiplex mycotoxins with a dynamic linear detection range of 0.1-10 ng/mL for ochratoxin A (OTA), 0.01-10 ng/mL for aflatoxins B 1 (AFB 1 ), and 0.001-10 ng/mL for fumonisin B 1 (FB 1 ) and limits of detection of 15.4, 1.48, and 0.21 pg/mL for OTA, AFB 1 , and FB 1 , respectively. The newly developed method shows good specificity and recovery rates. This method can provide a simple, sensitive, and cost-efficient platform for simultaneous screening of multiplex mycotoxins and can be easily expanded to the other aptamer-based protocol.
Lee, Kang Choon; Chun, Young Goo; Kim, Insoo; Shin, Beom Soo; Park, Eun-Seok; Yoo, Sun Dong; Youn, Yu Seok
2009-07-15
A simple, specific and sensitive derivatization with monobromobimane (mBrB) and the corresponding HPLC-fluorescence quantitation method for the analysis of bucillamine in human plasma was developed and validated. The analytical procedure involves a simple protein precipitation, pre-column fluorescence derivatization, and separation by reversed-phase high performance liquid chromatography (RP-HPLC). The calibration curve showed good linearity over a wide concentration range (50 ng/mL to 10 microg/mL) in human plasma (r(2)=0.9998). The lower limit of quantitation (LLOQ) was 50 ng/mL. The average precision and accuracy at LLOQ were within 6.3% and 107.6%, respectively. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (300 mg) of bucillamine to 20 healthy Korean volunteers.
Simple fluorescence-based detection of protein kinase A activity using a molecular beacon probe.
Ma, Changbei; Lv, Xiaoyuan; Wang, Kemin; Jin, Shunxin; Liu, Haisheng; Wu, Kefeng; Zeng, Weimin
2017-11-02
Protein kinase A was detected by quantifying the amount of ATP used after a protein kinase reaction. The ATP assay was performed using the T4 DNA ligase and a molecular beacon (MB). In the presence of ATP, DNA ligase catalyzed the ligation of short DNA. The ligation product then hybridized to MB, resulting in a fluorescence enhancement of the MB. This assay was capable of determining protein kinase A in the range of 12.5∼150 nM, with a detection limit of 1.25 nM. Furthermore, this assay could also be used to investigate the effect of genistein on protein kinase A. It was a universal, non-radioisotopic, and homogeneous method for assaying protein kinase A.
Ding, Yu; Li, Chunqiang
2016-01-01
Nanoscale particle tracking in three dimensions is crucial to directly observe dynamics of molecules and nanoparticles in living cells. Here we present a three-dimensional particle tracking method based on temporally focused two-photon excitation. Multiple particles are imaged at 30 frames/s in volume up to 180 × 180 × 100 µm3. The spatial localization precision can reach 50 nm. We demonstrate its capability of tracking fast swimming microbes at speed of ~200 µm/s. Two-photon dual-color tracking is achieved by simultaneously exciting two kinds of fluorescent beads at 800 nm to demonstrate its potential in molecular interaction studies. Our method provides a simple wide-field fluorescence imaging approach for deep multiple-particle tracking. PMID:27867724
Divya, O; Mishra, Ashok K
2007-05-29
Quantitative determination of kerosene fraction present in diesel has been carried out based on excitation emission matrix fluorescence (EEMF) along with parallel factor analysis (PARAFAC) and N-way partial least squares regression (N-PLS). EEMF is a simple, sensitive and nondestructive method suitable for the analysis of multifluorophoric mixtures. Calibration models consisting of varying compositions of diesel and kerosene were constructed and their validation was carried out using leave-one-out cross validation method. The accuracy of the model was evaluated through the root mean square error of prediction (RMSEP) for the PARAFAC, N-PLS and unfold PLS methods. N-PLS was found to be a better method compared to PARAFAC and unfold PLS method because of its low RMSEP values.
A simple method to extract DNA from hair shafts using enzymatic laundry powder.
Guan, Zheng; Zhou, Yu; Liu, Jinchuan; Jiang, Xiaoling; Li, Sicong; Yang, Shuming; Chen, Ailiang
2013-01-01
A simple method to extract DNA from hair shafts was developed by using enzymatic laundry powder at the first step of the process. The whole extraction can be finished in less than 2 hours. The simple extraction reagent proposed here contains only two cheap components: ordinary enzymatic laundry powder and PCR buffer. After extraction, an ultra sensitive fluorescent nucleic acid stain, PicoGreen, was used for quantifying trace amount of double-stranded DNA in the solution extracted. For further validation of DNA extraction, four primers were employed to amplify DNA microsatellite loci. Both fluorescence spectroscopy and PCR results suggested that this method can extract DNA from hair shafts with good efficiency and repeatability. The study will greatly facilitate the use of hair shafts in future for DNA analyses on genome-wide scale.
Yu, Fei; Guo, Menglin; Deng, Yabin; Lu, Yin; Chen, Lin; Huang, Ping; Li, Donghui
2016-01-01
We have found that a positively charged cationic copper phthalocyanine, Alcian blue (Alcian blue 8GX), can efficiently quench the fluorescence of an oppositely charged red fluorescent phthalocyanine compound with a matched molecular structure, tetrasulfonated aluminum phthalocyanine (AlS4Pc), because of the formation of an ion pair complex (AlS4Pc-Alcian blue 8GX) that exhibits almost no fluorescence. An investigation was carried out on the fluorescence recovery of AlS4Pc-Alcian blue 8GX caused by a series of anionic surfactants containing a sulfonic group (sodium dodecylbenzenesulfonate (SDBS), sodium lauryl sulfate (SLS), and sodium dodecyl sulfate (SDS)). The results showed that SDBS exhibited a significant response, and the highest sensitivity among the surfactants. Due to its high efficiency of fluorescence quenching and the high level of fluorescence recovery, direct observes can even be performed by the naked eye. The results revealed that the Alcian blue 8GX-AlS4Pc ion-pair complex fluorescent probe only responded to SDBS in the low-concentration range. Based on the new founding, this study proposed a novel principle and method of fluorescence enhancement to specifically measure the concentration of SDBS, thereby achieving a highly sensitive and highly specific determination of SDBS. Under the optimal conditions, the fluorescence intensity (I(f)) of the system and the concentration of SDBS in the range of 1 × 10(-7) - 1 × 10(-5) mol/dm(3) exhibited a good linear relationship. This method is highly sensitive, and the operation is simple and rapid. It had been applied for the quantitative analysis of SDBS in environmental water, while achieving satisfactory results compared with those of the standard method. This study developed a new application of the fluorescent phthalocyanine compounds used as molecular probes in analytical sciences.
A Simple low-cost device enables four epi-illumination techniques on standard light microscopes.
Ishmukhametov, Robert R; Russell, Aidan N; Wheeler, Richard J; Nord, Ashley L; Berry, Richard M
2016-02-08
Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.
A Simple low-cost device enables four epi-illumination techniques on standard light microscopes
NASA Astrophysics Data System (ADS)
Ishmukhametov, Robert R.; Russell, Aidan N.; Wheeler, Richard J.; Nord, Ashley L.; Berry, Richard M.
2016-02-01
Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.
Ma, Hengchang; Qin, Yanfang; Yang, Zenming; Yang, Manyi; Ma, Yucheng; Yin, Pei; Yang, Yuan; Wang, Tao; Lei, Ziqiang; Yao, Xiaoqiang
2018-04-25
Fluorescence-tunable materials are becoming increasingly attractive for their potential application in optics, electronics, and biomedical technology. Herein, a multi-color molecular pixel system is realized using simple copolymerization method. Bleeding both of complementary colors from blue and yellow fluorescence segments, reproduced a serious multicolor fluorescence materials. Interestingly, the emission colors of the polymers can be fine-tuned in solid state, solution phase, and in hydrogel state. More importantly, the positive fluorescent polymers exhibited cell-membrane permeable ability, and were found to accumulate on the cell nucleus, exhibiting remarkable selectivity to give bright fluorescence. The DNA/RNA selectivity experiments in vitro and in vivo verified that [tris(4-(pyridin-4-yl)phenyl)amine]-[1,8-dibromooctane] (TPPA-DBO) has prominent selectivity to DNA over RNA inside cells.
Maximizing fluorescence collection efficiency in multiphoton microscopy
Zinter, Joseph P.; Levene, Michael J.
2011-01-01
Understanding fluorescence propagation through a multiphoton microscope is of critical importance in designing high performance systems capable of deep tissue imaging. Optical models of a scattering tissue sample and the Olympus 20X 0.95NA microscope objective were used to simulate fluorescence propagation as a function of imaging depth for physiologically relevant scattering parameters. The spatio-angular distribution of fluorescence at the objective back aperture derived from these simulations was used to design a simple, maximally efficient post-objective fluorescence collection system. Monte Carlo simulations corroborated by data from experimental tissue phantoms demonstrate collection efficiency improvements of 50% – 90% over conventional, non-optimized fluorescence collection geometries at large imaging depths. Imaging performance was verified by imaging layer V neurons in mouse cortex to a depth of 850 μm. PMID:21934897
Noninvasive control of dental calculus removal: qualification of two fluorescence methods
NASA Astrophysics Data System (ADS)
Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Biryukova, T.
2013-02-01
The main condition of periodontitis prevention is the full calculus removal from the teeth surface. This procedure should be fulfilled without harming adjacent unaffected tooth tissues. Nevertheless the problem of sensitive and precise estimating of tooth-calculus interface exists and potential risk of hard tissue damage remains. In this work it was shown that fluorescence diagnostics during calculus removal can be successfully used for precise noninvasive detection of calculus-tooth interface. In so doing the simple implementation of this method free from the necessity of spectrometer using can be employed. Such a simple implementation of calculus detection set-up can be aggregated with the devices of calculus removing.
Dong, Yuwei; Fan, Ruiqing; Chen, Wei; Wang, Ping; Yang, Yulin
2017-05-23
A new simple 'dual' chemosensor MQA ((E)-2-methoxy-N-((quinolin-2-yl)methylene)aniline) for distinguishing Zn 2+ and Hg 2+ has been designed, synthesized and characterized. The sensor showed excellent selectivity and sensitivity with a fluorescence enhancement to Zn 2+ /Hg 2+ over other commonly coexisting cations (such as Na + , Mg 2+ , Al 3+ , K + , Mn 2+ , Fe 2+ , Fe 3+ , Co 2+ , Ni 2+ , Cu 2+ , Ga 3+ , Cd 2+ , In 3+ and Pb 2+ ) in DMSO-H 2 O solution (1/99 v/v), which was reversible with the addition of ethylenediaminetetraacetic acid (EDTA). The detection limit for Zn 2+ /Hg 2+ by MQA both reached the 10 -8 M level. The 1 : 1 ligand-to-metal coordination patterns of the MQA-Zn2+ and MQA-Hg2+ were calculated through a Job's plot and ESI-MS spectra, and were further confirmed by X-ray crystal structures of complexes MQA-Zn2+ and MQA-Hg2+. This chemosensor can recognize similar metal ions by coherently utilizing intramolecular charge transfer (ICT) and different electronic affinities of various metal ions. DFT calculations have revealed that the energy gap between the HOMO and LUMO of MQA has decreased upon coordination with Zn(ii)/Hg(ii).
Gao, Xuechuan; Zhai, Manjue; Guan, Weihua; Liu, Jingjuan; Liu, Zhiliang; Damirin, Alatangaole
2017-02-01
As a result of their extraordinarily large surfaces and well-defined pores, the design of a multifunctional metal-organic framework (MOF) is crucial for drug delivery but has rarely been reported. In this paper, a novel drug delivery system (DDS) based on nanoscale MOF was developed for use in cancer diagnosis and therapy. This MOF-based tumor targeting DDS was fabricated by a simple postsynthetic surface modification process. First, magnetic mesoporous nanomaterial Fe-MIL-53-NH 2 was used for encapsulating the drug and served as a magnetic resonance contrast agent. Moreover, the Fe-MIL-53-NH 2 nanomaterial exhibited a high loading capacity for the model anticancer drug 5-fluorouracil (5-FU). Subsequently, the fluorescence imaging agent 5-carboxyfluorescein (5-FAM) and the targeting reagent folic acid (FA) were conjugated to the 5-FU-loaded Fe-MIL-53-NH 2 , resulting in the advanced DDS Fe-MIL-53-NH 2 -FA-5-FAM/5-FU. Owing to the multifunctional surface modification, the obtained DDS Fe-MIL-53-NH 2 -FA-5-FAM/5-FU shows good biocompatibility, tumor enhanced cellular uptake, strong cancer cell growth inhibitory effect, excellent fluorescence imaging, and outstanding magnetic resonance imaging capability. Taken together, this study integrates diagnostic and treatment aspects into a single platform by a simple and efficient strategy, aiming for facilitating new possibilities for MOF use for multifunctional drug delivery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yinfa, Ma.
Thin-layer chromatography (TLC) is a broadly applicable separation technique. It offers many advantages over high performance liquid chromatography (HPLC), such as easily adapted for two-dimensional separation, for whole-column'' detection and for handling multiple samples, etc. However, due to its draggy development of detection techniques comparing with HPLC, TLC has not received the attention it deserves. Therefore, exploring new detection techniques is very important to the development of TLC. It is the principal of this dissertation to present a new detection method for TLC -- indirect fluorometric detection method. This detection technique is universal sensitive, nondestructive, and simple. This will bemore » described in detail from Sections 1 through Section 5. Section 1 and 3 describe the indirect fluorometric detection of anions and nonelectrolytes in TLC. In Section 2, a detection method for cations based on fluorescence quenching of ethidium bromide is presented. In Section 4, a simple and interesting TLC experiment is designed, three different fluorescence detection principles are used for the determination of caffeine, saccharin and sodium benzoate in beverages. A laser-based indirect fluorometric detection technique in TLC is developed in Section 5. Section 6 is totally different from Sections 1 through 5. An ultrasonic effect on the separation of DNA fragments in agarose gel electrophoresis is investigated. 262 refs.« less
Background subtraction for fluorescence EXAFS data of a very dilute dopant Z in Z + 1 host.
Medling, Scott; Bridges, Frank
2011-07-01
When conducting EXAFS at the Cu K-edge for ZnS:Cu with very low Cu concentration (<0.04% Cu), a large background was present that increased with energy. This background arises from a Zn X-ray Raman peak, which moves through the Cu fluorescence window, plus the tail of the Zn fluorescence peak. This large background distorts the EXAFS and must be removed separately before reducing the data. A simple means to remove this background is described.
Branigan, Emma; Pliotas, Christos; Hagelueken, Gregor; Naismith, James H
2013-11-01
Cysteine is an extremely useful site for selective attachment of labels to proteins for many applications, including the study of protein structure in solution by electron paramagnetic resonance (EPR), fluorescence spectroscopy and medical imaging. The demand for quantitative data for these applications means that it is important to determine the extent of the cysteine labeling. The efficiency of labeling is sensitive to the 3D context of cysteine within the protein. Where the label or modification is not directly measurable by optical or magnetic spectroscopy, for example, in cysteine modification to dehydroalanine, assessing labeling efficiency is difficult. We describe a simple assay for determining the efficiency of modification of cysteine residues, which is based on an approach previously used to determine membrane protein stability. The assay involves a reaction between the thermally unfolded protein and a thiol-specific coumarin fluorophore that is only fluorescent upon conjugation with thiols. Monitoring fluorescence during thermal denaturation of the protein in the presence of the dye identifies the temperature at which the maximum fluorescence occurs; this temperature differs among proteins. Comparison of the fluorescence intensity at the identified temperature between modified, unmodified (positive control) and cysteine-less protein (negative control) allows for the quantification of free cysteine. We have quantified both site-directed spin labeling and dehydroalanine formation. The method relies on a commonly available fluorescence 96-well plate reader, which rapidly screens numerous samples within 1.5 h and uses <100 μg of material. The approach is robust for both soluble and detergent-solubilized membrane proteins.
Joy, Abraham; Anim-Danso, Emmanuel; Kohn, Joachim
2009-01-01
Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are ~ 4 µmol/L by UV and <0.4 µmol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test strip is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(Bisphenol A carbonate). PMID:19782219
Nikoleli, Georgia-Paraskevi; Nikolelis, Dimitrios P; Methenitis, Constantinos
2010-08-18
This work describes the construction of a simple optical sensor for the rapid, selective and sensitive detection of urea in milk using air stable lipid films with incorporated urease. The lipid film is stabilized on a glass filter by polymerization using UV (ultra-violet) radiation prior its use. Methacrylic acid was the functional monomer, ethylene glycol dimethacrylate was the crosslinker and 2,2'-azobis-(2-methylpropionitrile) was the initiator. Urease is incorporated within this mixture prior to the polymerization. The presence of the enzyme in these films quenched this fluorescence and the colour became similar to that of the filters without the lipid films. A drop of aqueous solution of urea provided a "switching on" of the fluorescence which allows the rapid detection of this compound at the levels of 10(-8) M concentrations. The investigation of the effect of potent interferences included a wide range of compounds usually found in foods and also of proteins and lipids. These lipid membranes were used for the rapid detection of urea in milk. Copyright 2010 Elsevier B.V. All rights reserved.
Stroka, J; Anklam, E
2000-12-29
A simple, miniaturised and low power consuming (battery, fully semiconductor based) detector cell (SeBaDeC) was developed for the densitometric measurement of aflatoxins on TLC plates. A UV-light emitting diode (UV-LED) with a peak emission wavelength of 370 nm was used for fluorescence excitation, while a photo diode with a peak sensitivity of 440 nm in combination with a 418 nm cut-off filter was applied for detecting the fluorescence intensity. The resulting signal was further amplified by means of a commonly used operational amplifier integrated circuit (OA) and directly converted into a digital signal with a simple analogue-digital-converter (ADC). This signal was recorded at the serial (RS232) port of a portable PC and processed with a spreadsheet program. The software used for data recording is freeware and available in its source code, and the long lifetime of the UV-LED (up to 10 000 h) permits a maintenance free application of this device. This simplified device has shown to be able to detect concentrations of aflatoxins of 1 ng, thus offering a cheap and sensitive alternative to currently available TCL scanners.
Brooker, Holly R; Gyamfi, Irene A; Wieckowska, Agnieszka; Brooks, Nicholas J; Mulvihill, Daniel P; Geeves, Michael A
2018-06-21
Life is dependent upon the ability of a cell to rapidly respond to changes in environment. Small perturbations in local environments change the ability of molecules to interact and hence communicate. Hydrostatic pressure provides a rapid non-invasive, fully-reversible method for modulating affinities between molecules both in vivo and in vitro We have developed a simple fluorescence imaging chamber that allows intracellular protein dynamics and molecular events to be followed at pressures up to 200 bar in living cells. Using yeast we investigate the impact of hydrostatic pressure upon cell growth and cell cycle progression. While 100 bar has no affect upon viability, it induces a delay in chromosome segregation, resulting in the accumulation of long-undivided-bent cells, consistent with disruption of the cytoskeletons. This delay is independent of stress signalling and induces synchronisation of cell-cycle progression. Equivalent affects were observed in Candida albicans , with pressure inducing a reversible cell-cycle delay and hyphal growth. We present a simple novel non-invasive fluorescence microscopy based approach to transiently impact molecular dynamics to visualise, dissect and study signalling pathways and cellular processes in living cells. © 2018. Published by The Company of Biologists Ltd.
NASA Astrophysics Data System (ADS)
Clarke, Samuel; Tamang, Sudarsan; Reiss, Peter; Dahan, Maxime
2011-04-01
Nanoparticles are now utilized in many diverse biological and medical applications. Despite this, it remains challenging to tailor their surface for specific molecular targeting while maintaining high biocompatibility. To address this problem, we evaluate a phytochelatin-related peptide surface coating to produce functional and biocompatible nanoparticles (NPs) based on fluorescent InP/ZnS and CdSe/ZnS or superparamagnetic FePt and Fe3O4. Using a combination of transmission electron microscopy, size-exclusion chromatography and gel electrophoresis (GE), we demonstrate the excellent colloidal properties of the peptide-coated NPs (pNPs) and the compact nature of the coating (~4 nm thickness). We develop a simple protocol for the monofunctionalization of the pNPs with targeting biomolecules, by combining covalent conjugation with GE purification. We then employ functionalized InP/ZnS pNPs in a live-cell, single-molecule imaging application to specifically target and detect individual proteins in the cell membrane. These findings showcase the versatility of the peptides for preparing compact NPs of various compositions and sizes, which are easily functionalized, and suitable for a broad range of biomedical applications.
Clarke, Samuel; Tamang, Sudarsan; Reiss, Peter; Dahan, Maxime
2011-04-29
Nanoparticles are now utilized in many diverse biological and medical applications. Despite this, it remains challenging to tailor their surface for specific molecular targeting while maintaining high biocompatibility. To address this problem, we evaluate a phytochelatin-related peptide surface coating to produce functional and biocompatible nanoparticles (NPs) based on fluorescent InP/ZnS and CdSe/ZnS or superparamagnetic FePt and Fe(3)O(4). Using a combination of transmission electron microscopy, size-exclusion chromatography and gel electrophoresis (GE), we demonstrate the excellent colloidal properties of the peptide-coated NPs (pNPs) and the compact nature of the coating (∼4 nm thickness). We develop a simple protocol for the monofunctionalization of the pNPs with targeting biomolecules, by combining covalent conjugation with GE purification. We then employ functionalized InP/ZnS pNPs in a live-cell, single-molecule imaging application to specifically target and detect individual proteins in the cell membrane. These findings showcase the versatility of the peptides for preparing compact NPs of various compositions and sizes, which are easily functionalized, and suitable for a broad range of biomedical applications.
Xu, Xiao-Yu; Lian, Xiao; Hao, Ji-Na; Zhang, Chi; Yan, Bing
2017-10-01
Unsafe food is a huge threat to human health and the economy, and detecting food spoilage early is an ongoing and imperative need. Herein, a simple and effective strategy combining a fluorescence sensor and one-to-two logic operation is designed for monitoring biogenic amines, indicators of food spoilage. Sensors (methyl red@lanthanide metal-organic frameworks (MR@EuMOFs)) are created by covalently modifying MR into NH 2 -rich EuMOFs, which have a high quantum yield (48%). A double-stimuli-responsive fluorescence center is produced via energy transfer from the ligands to Eu 3+ and MR. Portable sensory hydrogels are obtained by dispersing and solidifying MR@EuMOFs in water-phase sodium salt of carboxy methyl cellulose (CMC-Na). The hydrogels exhibit a color transition upon "smelling" histamine (HI) vapor. This transition and shift in the MR-based emission peak are closely related to the HI concentration. Using the HI concentration as the input signal and the two fluorescence emissions as output signals, an advanced analytical device based on a one-to-two logic gate is constructed. The four output combinations, NOT (0, 1), YES (1, 0), PASS 1 (1, 1), and PASS 0 (0, 0), allow the direct analysis of HI levels, which can be used for real-time food-freshness evaluation. The novel strategy suggested here may be a new application for a molecular logic system in the sensing field. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sun, Yueying; Lu, Xiaohui; Su, Fengxia; Wang, Limei; Liu, Chenghui; Duan, Xinrui; Li, Zhengping
2015-12-15
Most of practical methods for detection of single nucleotide polymorphism (SNP) need at least two steps: amplification (usually by PCR) and detection of SNP by using the amplification products. Ligase chain reaction (LCR) can integrate the amplification and allele discrimination in one step. However, the detection of LCR products still remains a great challenge for highly sensitive and quantitative SNP detection. Herein, a simple but robust strategy for real-time fluorescence LCR has been developed for highly sensitive and quantitative SNP detection. A pair of LCR probes are firstly labeled with a fluorophore and a quencher, respectively. When the pair of LCR probes are ligated in LCR, the fluorophore will be brought close to the quencher, and thus, the fluorescence will be specifically quenched by fluorescence resonance energy transfer (FRET). The decrease of fluorescence intensity resulted from FRET can be real-time monitored in the LCR process. With the proposed real-time fluorescence LCR assay, 10 aM DNA targets or 100 pg genomic DNA can be accurately determined and as low as 0.1% mutant DNA can be detected in the presence of a large excess of wild-type DNA, indicating the high sensitivity and specificity. The real-time measuring does not require the detection step after LCR and gives a wide dynamic range for detection of DNA targets (from 10 aM to 1 pM). As LCR has been widely used for detection of SNP, DNA methylation, mRNA and microRNA, the real-time fluorescence LCR assay shows great potential for various genetic analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Wu, Chuan-Liu; Zhao, Yi-Bing
2007-06-01
Water-soluble cadmium sulfide (CdS) quantum dots (QDs) capped by mercaptoacetic acid were synthesized by aqueous-phase arrested precipitation, and characterized by transmission electron microscopy, spectrofluorometry, and UV-Vis spectrophotometry. The prepared luminescent water-soluble CdS QDs were evaluated as fluorescence probes for the detection of highly reactive hydrogen selenide ions (HSe(-) ions). The quenching of the fluorescence emission of CdS QDs with the addition of HSe(-) ions is due to the elimination of the S(2-) vacancies which are luminescence centers. Quantitative analysis based on chemical interaction between HSe(-) ions and the surface of CdS QDs is very simple, easy to develop, and has demonstrated very high sensitivity and selectivity features. The effect of foreign ions (common anions and biologically relevant cations) on the fluorescence of the CdS QDs was examined to evaluate the selectivity. Only Cu(2+) and S(2-) ions exhibit significant effects on the fluorescence of CdS QDs. With the developed method, we are able to determine the concentration of HSe(-) ions in the range from 0.10 to 4.80 micromol L(-1), and the limit of detection is 0.087 micromol L(-1). The proposed method was successfully applied to monitor the obtained HSe(-) ions from the reaction of glutathione with selenite. To the best of our knowledge, this is the first report on fluorescence analysis of HSe(-) ions in aqueous solution.
A Robust Damage-Reporting Strategy for Polymeric Materials Enabled by Aggregation-Induced Emission.
Robb, Maxwell J; Li, Wenle; Gergely, Ryan C R; Matthews, Christopher C; White, Scott R; Sottos, Nancy R; Moore, Jeffrey S
2016-09-28
Microscopic damage inevitably leads to failure in polymers and composite materials, but it is difficult to detect without the aid of specialized equipment. The ability to enhance the detection of small-scale damage prior to catastrophic material failure is important for improving the safety and reliability of critical engineering components, while simultaneously reducing life cycle costs associated with regular maintenance and inspection. Here, we demonstrate a simple, robust, and sensitive fluorescence-based approach for autonomous detection of damage in polymeric materials and composites enabled by aggregation-induced emission (AIE). This simple, yet powerful system relies on a single active component, and the general mechanism delivers outstanding performance in a wide variety of materials with diverse chemical and mechanical properties.
Travagliati, Marco; Girardo, Salvatore; Pisignano, Dario; Beltram, Fabio; Cecchini, Marco
2013-09-03
Spatiotemporal image correlation spectroscopy (STICS) is a simple and powerful technique, well established as a tool to probe protein dynamics in cells. Recently, its potential as a tool to map velocity fields in lab-on-a-chip systems was discussed. However, the lack of studies on its performance has prevented its use for microfluidics applications. Here, we systematically and quantitatively explore STICS microvelocimetry in microfluidic devices. We exploit a simple experimental setup, based on a standard bright-field inverted microscope (no fluorescence required) and a high-fps camera, and apply STICS to map liquid flow in polydimethylsiloxane (PDMS) microchannels. Our data demonstrates optimal 2D velocimetry up to 10 mm/s flow and spatial resolution down to 5 μm.
Tiwari, Karishma; Kumar, Sumit; Kumar, Vipan; Kaur, Jeevanjot; Arora, Saroj; Mahajan, Rakesh Kumar
2018-02-15
A simple and cost effective unsymmetrical azine based Schiff base, 5-diethylamino-2-[(2-hydroxy-benzylidene)hydrazonomethyl]-phenol (1) was synthesized which selectively detect Cu 2+ ions in the presence of other competitive ions through "naked eye" in physiological conditions (EtOH-buffer (1:1, v/v, HEPES 10mM, pH=7.4)). The presence of Cu 2+ induce color change from light yellow green to yellow with the appearance of a new band at 450nm in UV-Vis spectra of Schiff base 1. The fluorescence of Schiff base 1 (10μM) was quenched completely in the presence of 2.7 equiv. of Cu 2+ ions. Sub-micromolar limit of detection (LOD=3.4×10 -7 M), efficient Stern-Volmer quenching constant (K SV =1.8×10 5 Lmol -1 ) and strong binding constant (log K b =5.92) has been determined with the help of fluorescence titration profile. Further, 1-Cu 2+ complex was employed for the detection of phosphate ions (PO 4 3- , HPO 4 2- and H 2 PO 4 - ) at micromolar concentrations in EtOH-buffer of pH7.4 based on fluorescence recovery due to the binding of Cu 2+ with phosphate ions. Solubility at low concentration in aqueous medium, longer excitation (406nm) and emission wavelength (537nm), and biocompatibility of Schiff base 1 formulates its use in live cell imaging. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Weiping; Lu, Ya-Chun; Huang, Hong; Feng, Jiu-Ju; Chen, Jian-Rong; Wang, Ai-Jun
2014-04-07
A simple, facile and green hydrothermal method was developed in the synthesis of water-soluble nitrogen-doped carbon dots (N-CDs) from streptomycin. The as-prepared N-CDs displayed bright blue fluorescence under the irradiation of UV light, together with a high quantum yield of 7.6% and good biocompatibility as demonstrated by the cell viability assay. Thus, the N-CDs can be used as fluorescent probes for cell imaging, which have potential applications in bioimaging and related fields. This strategy opens a new way for the preparation of fluorescent carbon nanomaterials using small molecules as carbon sources.
NASA Astrophysics Data System (ADS)
Ilias, Michail A.; Richter, Johan; Westermark, Frida; Brantmark, Martin; Andersson-Engels, Stefan; Wårdell, Karin
2007-07-01
The highly malignant brain tumor, glioblastoma multiforme, is difficult to totally resect without aid due to its infiltrative way of growing and its morphological similarities to surrounding functioning brain under direct vision in the operating field. The need for an inexpensive and robust real-time visualizing system for resection guiding in neurosurgery has been formulated by research groups all over the world. The main goal is to develop a system that helps the neurosurgeon to make decisions during the surgical procedure. A compact fiber optic system using fluorescence spectroscopy has been developed for guiding neurosurgical resections. The system is based on a high power light emitting diode at 395 nm and a spectrometer. A fiber bundle arrangement is used to guide the excitation light and fluorescence light between the instrument and the tissue target. The system is controlled through a computer interface and software package especially developed for the application. This robust and simple instrument has been evaluated in vivo both on healthy skin but also during a neurosurgical resection procedure. Before surgery the patient received orally a low dose of 5-aminolevulinic acid, converted to the fluorescence tumor marker protoporphyrin IX in the malignant cells. Preliminary results indicate that PpIX fluorescence and brain tissue autofluorescence can be recorded with the help of the developed system intraoperatively during resection of glioblastoma multiforme.
Selection of fluorophore and quencher pairs for fluorescent nucleic acid hybridization probes.
Marras, Salvatore A E
2006-01-01
With the introduction of simple and relatively inexpensive methods for labeling nucleic acids with nonradioactive labels, doors have been opened that enable nucleic acid hybridization probes to be used for research and development, as well as for clinical diagnostic applications. The use of fluorescent hybridization probes that generate a fluorescence signal only when they bind to their target enables real-time monitoring of nucleic acid amplification assays. The use of hybridization probes that bind to the amplification products in real-time markedly improves the ability to obtain quantitative results. Furthermore, real-time nucleic acid amplification assays can be carried out in sealed tubes, eliminating carryover contamination. Because fluorescent hybridization probes are available in a wide range of colors, multiple hybridization probes, each designed for the detection of a different nucleic acid sequence and each labeled with a differently colored fluorophore, can be added to the same nucleic acid amplification reaction, enabling the development of high-throughput multiplex assays. It is therefore important to carefully select the labels of hybridization probes, based on the type of hybridization probe used in the assay, the number of targets to be detected, and the type of apparatus available to perform the assay. This chapter outlines different aspects of choosing appropriate labels for the different types of fluorescent hybridization probes used with different types of spectrofluorometric thermal cyclers.
Hung, Szu-Ying; Shih, Ya-Chen; Tseng, Wei-Lung
2015-02-01
This study describes the development of a simple, enzyme-free, label-free, sensitive, and selective system for detecting adenosine based on the use of Tween 20-stabilized gold nanoparticles (Tween 20-AuNPs) as an efficient fluorescence quencher for boron dipyrromethene-conjugated adenosine 5'-triphosphate (BODIPY-ATP) and as a recognition element for adenosine. BODIPY-ATP can interact with Tween 20-AuNPs through the coordination between the adenine group of BODIPY-ATP and Au atoms on the NP surface, thereby causing the fluorescence quenching of BODIPY-ATP through the nanometal surface energy transfer (NSET) effect. When adenosine attaches to the NP surface, the attached adenosine exhibits additional electrostatic attraction to BODIPY-ATP. As a result, the presence of adenosine enhances the efficiency of AuNPs in fluorescence quenching of BODIPY-ATP. The AuNP-induced fluorescence quenching of BODIPY-ATP progressively increased with an increase in the concentration of adenosine; the detection limit at a signal-to-noise ratio of 3 for adenosine was determined to be 60nM. The selectivity of the proposed system was more than 1000-fold for adenosine over any adenosine analogs and other nucleotides. The proposed system combined with a phenylboronic acid-containing column was successfully applied to the determination of adenosine in urine. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Ya; Liu, Nan; Liu, Hui; Wang, Yu; Hao, Yuwei; Ma, Xinhua; Li, Xiaoli; Huo, Yapeng; Lu, Jiahai; Tang, Shuge; Wang, Caiqin; Zhang, Yinhong; Gao, Zhixian
2017-04-01
A novel label-free fluorescence assay for detection of Hg2+ was developed based on the Hg2+-binding single-stranded DNA (ssDNA) and SYBR Green I (SG I). Differences from other assays, the designed rich-thymine (T) ssDNA probe without fluorescent labelling can be rapidly formed a T-Hg2+-T complex and folded into a stable hairpin structure in the presence of Hg2+ in environmental drinking water samples by facilitating fluorescence increase through intercalating with SG I in one-step. In the assay, the fluorescence signal can be directly obtained without additional incubation within 1 min. The dynamic quantitative working ranges was 5-1000 nM, the determination coefficients were satisfied by optimization of the reaction conditions. The lowest detection limit of Hg2+ was 3 nM which is well below the standard of U.S. Environmental Protection Agency. This method was highly specific for detecting of Hg2+ without being affected by other possible interfering ions from different background compositions of water samples. The recoveries of Hg2+ spiked in these samples were 95.05-103.51%. The proposed method is more viable, low-costing and simple for operation in field detection than the other methods with great potentials, such as emergency disposal, environmental monitoring, surveillance and supporting of ecological risk assessment and management.
Okamura, Yukio; Kondo, Satoshi; Sase, Ichiro; Suga, Takayuki; Mise, Kazuyuki; Furusawa, Iwao; Kawakami, Shigeki; Watanabe, Yuichiro
2000-01-01
A set of fluorescently-labeled DNA probes that hybridize with the target RNA and produce fluorescence resonance energy transfer (FRET) signals can be utilized for the detection of specific RNA. We have developed probe sets to detect and discriminate single-strand RNA molecules of plant viral genome, and sought a method to improve the FRET signals to handle in vivo applications. Consequently, we found that a double-labeled donor probe labeled with Bodipy dye yielded a remarkable increase in fluorescence intensity compared to a single-labeled donor probe used in an ordinary FRET. This double-labeled donor system can be easily applied to improve various FRET probes since the dependence upon sequence and label position in enhancement is not as strict. Furthermore this method could be applied to other nucleic acid substances, such as oligo RNA and phosphorothioate oligonucleotides (S-oligos) to enhance FRET signal. Although the double-labeled donor probes labeled with a variety of fluorophores had unexpected properties (strange UV-visible absorption spectra, decrease of intensity and decay of donor fluorescence) compared with single-labeled ones, they had no relation to FRET enhancement. This signal amplification mechanism cannot be explained simply based on our current results and knowledge of FRET. Yet it is possible to utilize this double-labeled donor system in various applications of FRET as a simple signal-enhancement method. PMID:11121494
Photoinduced Electron Transfer Based Ion Sensing within an Optical Fiber
Englich, Florian V.; Foo, Tze Cheung; Richardson, Andrew C.; Ebendorff-Heidepriem, Heike; Sumby, Christopher J.; Monro, Tanya M.
2011-01-01
We combine suspended-core microstructured optical fibers with the photoinduced electron transfer (PET) effect to demonstrate a new type of fluorescent optical fiber-dip sensing platform for small volume ion detection. A sensor design based on a simple model PET-fluoroionophore system and small core microstructured optical fiber capable of detecting sodium ions is demonstrated. The performance of the dip sensor operating in a high sodium concentration regime (925 ppm Na+) and for lower sodium concentration environments (18.4 ppm Na+) is explored and future approaches to improving the sensor’s signal stability, sensitivity and selectivity are discussed. PMID:22163712
A pyrene-based fluorescent sensor for Zn2+ ions: a molecular 'butterfly'.
Manandhar, Erendra; Broome, J Hugh; Myrick, Jalin; Lagrone, Whitney; Cragg, Peter J; Wallace, Karl J
2011-08-21
A simple pyrene-based triazole receptor has been synthesised and shown to self-assemble in the presence of ZnCl(2) in an exclusively 2:1 ratio, whereas a mixture of 2:1 and 1:1 ratios are observed for other Zn(2+) salts. The pyrene units are syn in orientation; this is supported by a strong excimer signal observed at 410 nm in the presence of ZnCl(2) in acetonitrile. DFT calculations and 2D NMR support the proposed structure. This journal is © The Royal Society of Chemistry 2011
Sun, Ning; Shibata, Brad; Hess, John F.
2015-01-01
Purpose Several properties of ocular tissue make fixation for light microscopy problematic. Because the eye is spherical, immersion fixation necessarily results in a temporal gradient of fixation, with surfaces fixing more rapidly and thoroughly than interior structures. The problem is compounded by the fact that the layers of the eye wall are compositionally quite different, resulting in different degrees of fixation-induced shrinkage and distortion. Collectively, these result in non-uniform preservation, as well as buckling and/or retinal detachment. This gradient problem is most acute for the lens, where the density of proteins can delay fixation of the central lens for days, and where the fixation gradient parallels the age gradient of lens cells, which complicates data interpretation. Our goal was to identify a simple method for minimizing some of the problems arising from immersion fixation, which avoided covalent modification of antigens, retained high quality structure, and maintained tissue in a state that is amenable to common cytochemical techniques. Methods A simple and inexpensive derivative of the freeze-substitution approach was developed and compared to fixation by immersion in formalin. Preservation of structure, immunoreactivity, GFP and tdTomato fluorescence, lectin reactivity, outer segment auto fluorescence, Click-iT chemistry, compatibility with in situ hybdrdization, and the ability to rehydrate eyes after fixation by freeze substitution for subsequent cryo sectioning were assessed. Results An inexpensive and simple variant of the freeze substitution approach provides excellent structural preservation for light microscopy, and essentially eliminates ocular buckling, retinal detachment, and outer segment auto-fluorescence, without covalent modification of tissue antigens. The approach shows a notable improvement in preservation of immunoreactivity. TdTomato intrinsic fluorescence is also preserved, as is compatibility with in situ hybridization, lectin labeling, and the Click-iT chemistry approach to labeling the thymidine analog EdU. On the negative side, this approach dramatically reduced intrinsic GFP fluorescence. Conclusions A simple, cost-effective derivative of the freeze substitution process is described that is of particular value in the study of rodent or other small eyes, where fixation gradients, globe buckling, retinal detachment, differential shrinkage, autofluorescence, and tissue immunoreactivity have been problematic. PMID:25991907
Synchronous fluorescence spectroscopic study of solvatochromic curcumin dye
NASA Astrophysics Data System (ADS)
Patra, Digambara; Barakat, Christelle
2011-09-01
Curcumin, the main yellow bioactive component of turmeric, has recently acquired attention by chemists due its wide range of potential biological applications as an antioxidant, an anti-inflammatory, and an anti-carcinogenic agent. This molecule fluoresces weakly and poorly soluble in water. In this detailed study of curcumin in thirteen different solvents, both the absorption and fluorescence spectra of curcumin was found to be broad, however, a narrower and simple synchronous fluorescence spectrum of curcumin was obtained at Δ λ = 10-20 nm. Lippert-Mataga plot of curcumin in different solvents illustrated two sets of linearity which is consistent with the plot of Stokes' shift vs. the ET30. When Stokes's shift in wavenumber scale was replaced by synchronous fluorescence maximum in nanometer scale, the solvent polarity dependency measured by λSFSmax vs. Lippert-Mataga plot or ET30 values offered similar trends as measured via Stokes' shift for protic and aprotic solvents for curcumin. Better linear correlation of λSFSmax vs. π* scale of solvent polarity was found compared to λabsmax or λemmax or Stokes' shift measurements. In Stokes' shift measurement both absorption/excitation as well as emission (fluorescence) spectra are required to compute the Stokes' shift in wavenumber scale, but measurement could be done in a very fast and simple way by taking a single scan of SFS avoiding calculation and obtain information about polarity of the solvent. Curcumin decay properties in all the solvents could be fitted well to a double-exponential decay function.
Yoshida, Terumitsu; Takahashi, Ryohei; Imai, Koichi; Uchida, Hiroshi; Arai, Yasutoshi; Oh-ishi, Tsutomu
2010-03-01
This study developed a simple and sensitive method using reversed-phase high-performance liquid chromatography (HPLC) for ganciclovir (GCV) plasma concentrations in cytomegalovirus infectious infants with hearing loss. The method involves a simple protein precipitation procedure that uses no solid-phase or liquid-liquid extraction. The HPLC separation was carried out on a Cadenza CD-C(18) column (3 microm, 4.6 mm x 150 mm) with phosphate buffer (pH 2.5, 25 mM) containing 1% methanol-acetonitrile mixture (4:3, v/v) as a mobile phase at a 0.7 mL/min flow rate. GCV was detected using a fluorescence detection (lambdaex/em: 265/380 nm). The quantification limit was 0.025 microg/mL for 100 microL of plasma sample at which good intra- and inter-assay coefficient of variation values (< 4.96%) and recoveries (94.9-96.5%) were established.
Fourier-interpolation superresolution optical fluctuation imaging (fSOFi) (Conference Presentation)
NASA Astrophysics Data System (ADS)
Enderlein, Joerg; Stein, Simon C.; Huss, Anja; Hähnel, Dirk; Gregor, Ingo
2016-02-01
Stochastic Optical Fluctuation Imaging (SOFI) is a superresolution fluorescence microscopy technique which allows to enhance the spatial resolution of an image by evaluating the temporal fluctuations of blinking fluorescent emitters. SOFI is not based on the identification and localization of single molecules such as in the widely used Photoactivation Localization Microsopy (PALM) or Stochastic Optical Reconstruction Microscopy (STORM), but computes a superresolved image via temporal cumulants from a recorded movie. A technical challenge hereby is that, when directly applying the SOFI algorithm to a movie of raw images, the pixel size of the final SOFI image is the same as that of the original images, which becomes problematic when the final SOFI resolution is much smaller than this value. In the past, sophisticated cross-correlation schemes have been used for tackling this problem. Here, we present an alternative, exact, straightforward, and simple solution using an interpolation scheme based on Fourier transforms. We exemplify the method on simulated and experimental data.
Photothermal imaging of skeletal muscle mitochondria.
Tomimatsu, Toru; Miyazaki, Jun; Kano, Yutaka; Kobayashi, Takayoshi
2017-06-01
The morphology and topology of mitochondria provide useful information about the physiological function of skeletal muscle. Previous studies of skeletal muscle mitochondria are based on observation with transmission, scanning electron microscopy or fluorescence microscopy. In contrast, photothermal (PT) microscopy has advantages over the above commonly used microscopic techniques because of no requirement for complex sample preparation by fixation or fluorescent-dye staining. Here, we employed the PT technique using a simple diode laser to visualize skeletal muscle mitochondria in unstained and stained tissues. The fine mitochondrial network structures in muscle fibers could be imaged with the PT imaging system, even in unstained tissues. PT imaging of tissues stained with toluidine blue revealed the structures of subsarcolemmal (SS) and intermyofibrillar (IMF) mitochondria and the swelling behavior of mitochondria in damaged muscle fibers with sufficient image quality. PT image analyses based on fast Fourier transform (FFT) and Grey-level co-occurrence matrix (GLCM) were performed to derive the characteristic size of mitochondria and to discriminate the image patterns of normal and damaged fibers.
Protein detection using biobarcodes.
Müller, Uwe R
2006-10-01
Over the past 50 years the development of assays for the detection of protein analytes has been driven by continuing demands for higher levels of sensitivity and multiplexing. The result has been a progression of sandwich-type immunoassays, starting with simple radioisotopic, colorimetric, or fluorescent labeling systems to include various enzymatic or nanostructure-based signal amplification schemes, with a concomitant sensitivity increase of over 1 million fold. Multiplexing of samples and tests has been enabled by microplate and microarray platforms, respectively, or lately by various molecular barcoding systems. Two different platforms have emerged as the current front-runners by combining a nucleic acid amplification step with the standard two-sided immunoassay. In both, the captured protein analyte is replaced by a multiplicity of oligonucleotides that serve as surrogate targets. One of these platforms employs DNA or RNA polymerases for the amplification step, while detection is by fluorescence. The other is based on gold nanoparticles for both amplification as well as detection. The latter technology, now termed Biobarcode, is completely enzyme-free and offers potentially much higher multiplexing power.
Qian, Wenjuan; Lu, Ying; Meng, Youqing; Ye, Zunzhong; Wang, Liu; Wang, Rui; Zheng, Qiqi; Wu, Hui; Wu, Jian
2018-06-06
' Candidatus Liberibacter asiaticus' (Las) is the most prevalent bacterium associated with huanglongbing, which is one of the most destructive diseases of citrus. In this paper, an extremely rapid and simple method for field detection of Las from leaf samples, based on recombinase polymerase amplification (RPA), is described. Three RPA primer pairs were designed and evaluated. RPA amplification was optimized so that it could be accomplished within 10 min. In combination with DNA crude extraction by a 50-fold dilution after 1 min of grinding in 0.5 M sodium hydroxide and visual detection via fluorescent DNA dye (positive samples display obvious green fluorescence while negative samples remain colorless), the whole detection process can be accomplished within 15 min. The sensitivity and specificity of this RPA-based method were evaluated and were proven to be equal to those of real-time PCR. The reliability of this method was also verified by analyzing field samples.
Application of bacteriophages in sensor development.
Peltomaa, Riikka; López-Perolio, Irene; Benito-Peña, Elena; Barderas, Rodrigo; Moreno-Bondi, María Cruz
2016-03-01
Bacteriophage-based bioassays are a promising alternative to traditional antibody-based immunoassays. Bacteriophages, shortened to phages, can be easily conjugated or genetically engineered. Phages are robust, ubiquitous in nature, and harmless to humans. Notably, phages do not usually require inoculation and killing of animals; and thus, the production of phages is simple and economical. In recent years, phage-based biosensors have been developed featuring excellent robustness, sensitivity, and selectivity in combination with the ease of integration into transduction devices. This review provides a critical overview of phage-based bioassays and biosensors developed in the last few years using different interrogation methods such as colorimetric, enzymatic, fluorescence, surface plasmon resonance, quartz crystal microbalance, magnetoelastic, Raman, or electrochemical techniques.
NASA Astrophysics Data System (ADS)
Kang, Yvonne Q.; François, Alexandre; Riesen, Nicolas; Monro, Tanya M.
2018-02-01
Whispering Gallery Mode (WGM) biosensors have been widely exploited over the past decade, owing to their unprecedented detection limits and label free capability. WGM based sensing mechanisms, such as resonance frequency shift, linewidth broadening, and splitting of the two counter-propagating WGMs, have been extensively researched and applied for bio-chemical sensing. However, the mode-splitting of the originally degenerate WGMs from different equatorial planes on a fluorescent microsphere has not been fully investigated. In this work, we break the symmetry of the surrounding environment outside the microsphere by partially embedding the sphere into a high-refractive-index medium (i.e. glue), to lift the degeneracy of the modes from different WGM planes. The split-modes from multiple planes of the fluorescent microsphere are indiscriminately collected. It is found that the effective quality factor Q of the WGMs increases non-conventionally as the Refractive Index (RI) of the probing liquid increases up to the point where it is equal to that of the glue. This presents a new methodology for quantifying changes in the probing environment based on the Q spoiling of the resonances as determined by the RI difference between the environment and that of the reference glue. Furthermore, we find that this sensing platform opens the door to simple self-referenced sensing techniques based on the analysis of the spectral positions of subsets of the split modes.
Park, In Seob; Komiyama, Hideaki; Yasuda, Takuma
2017-02-01
Deep-blue emitters that can harvest both singlet and triplet excited states to give high electron-to-photon conversion efficiencies are highly desired for applications in full-color displays and white lighting devices based on organic light-emitting diodes (OLEDs). Thermally activated delayed fluorescence (TADF) molecules based on highly twisted donor-acceptor (D-A) configurations are promising emitting dopants for the construction of efficient deep-blue OLEDs. In this study, a simple and versatile D-A system combining acridan-based donors and pyrimidine-based acceptors has been developed as a new platform for high-efficiency deep-blue TADF emitters. The designed pre-twisted acridan-pyrimidine D-A molecules exhibit small singlet-triplet energy splitting and high photoluminescence quantum yields, functioning as efficient deep-blue TADF emitters. The OLEDs utilizing these TADF emitters display bright blue electroluminescence with external quantum efficiencies of up to 20.4%, maximum current efficiencies of 41.7 cd A -1 , maximum power efficiencies of 37.2 lm W -1 , and color coordinates of (0.16, 0.23). The design strategy featuring such acridan-pyrimidine D-A motifs can offer great prospects for further developing high-performance deep-blue TADF emitters and TADF-OLEDs.
Khan, Muhammad Naeem; Shah, Jasmin; Jan, Muhammad Rasul; Lee, Sang Hak
2013-01-01
A simple, sensitive, and accurate spectrofluorimetric method was developed for the determination of citalopram in bulk and pharmaceutical preparations. The method is based on the enhancement of the weak fluorescence signal (FL) of the Tb (III)-citalopram system in the presence of silver nanoparticles. Fluorescence intensities were measured at 555 nm after excitation at 281 nm. Prepared silver nanoparticles (AgNPs) were characterized by UV-Visible spectra and transmission electron microscopy (TEM). Various factors affecting the formation of citalopram-Tb (III)-AgNPs complexes were studied and optimized. The fluorescence intensity versus concentration plot was linear over the range 0.02-14 μg mL(-1), with an excellent correlation coefficient of 0.9978. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 7.15 × 10(-6) μg mL(-1) and 2.38 × 10(-5) μg mL(-1) respectively. The proposed method was found to have good reproducibility with a relative standard deviation of 3.66% (n = 6). The interference effects of common excipients found in pharmaceutical preparations were studied. The developed method was validated statistically by performing recoveries studies and successfully applied for the assay of citalopram in bulk powder and pharmaceutical preparations. Percent recoveries were found to range from 98.98% to 100.97% for bulk powder and from 96.57% to 101.77% for pharmaceutical preparations.
Shi, Xiaojun; Kohram, Maryam; Zhuang, Xiaodong; Smith, Adam W
2016-02-23
Phosphatidylinositol phosphate (PIP) lipids are critical to many cell signaling pathways, in part by acting as molecular beacons that recruit peripheral membrane proteins to specific locations within the plasma membrane. Understanding the biophysics of PIP-protein interactions is critical to developing a chemically detailed model of cell communication. Resolving such interactions is challenging, even in model membrane systems, because of the difficulty in preparing PIP-containing membranes with high fluidity and integrity. Here we report on a simple, vesicle-based protocol for preparing asymmetric supported lipid bilayers in which fluorescent PIP lipid analogues are found only on the top leaflet of the supported membrane facing the bulk solution. With this asymmetric distribution of lipids between the leaflets, the fluorescent signal from the PIP lipid analogue reports directly on interactions between the peripheral molecules and the top leaflet of the membrane. Asymmetric PIP-containing bilayers are an ideal platform to investigate the interaction of PIP with peripheral membrane proteins using fluorescence-based imaging approaches. We demonstrate their usefulness here with a combined fluorescence correlation spectroscopy and single particle tracking study of the interaction between PIP2 lipids and a polycationic polymer, quaternized polyvinylpyridine (QPVP). With this approach we are able to quantify the microscopic features of the mobility coupling between PIP2 lipids and polybasic QPVP. With single particle tracking we observe individual PIP2 lipids switch from Brownian to intermittent motion as they become transiently trapped by QPVP.
Quantum Dot Enabled Molecular Sensing and Diagnostics
Zhang, Yi; Wang, Tza-Huei
2012-01-01
Since its emergence, semiconductor nanoparticles known as quantum dots (QDs) have drawn considerable attention and have quickly extended their applicability to numerous fields within the life sciences. This is largely due to their unique optical properties such as high brightness and narrow emission band as well as other advantages over traditional organic fluorophores. New molecular sensing strategies based on QDs have been developed in pursuit of high sensitivity, high throughput, and multiplexing capabilities. For traditional biological applications, QDs have already begun to replace traditional organic fluorophores to serve as simple fluorescent reporters in immunoassays, microarrays, fluorescent imaging applications, and other assay platforms. In addition, smarter, more advanced QD probes such as quantum dot fluorescence resonance energy transfer (QD-FRET) sensors, quenching sensors, and barcoding systems are paving the way for highly-sensitive genetic and epigenetic detection of diseases, multiplexed identification of infectious pathogens, and tracking of intracellular drug and gene delivery. When combined with microfluidics and confocal fluorescence spectroscopy, the detection limit is further enhanced to single molecule level. Recently, investigations have revealed that QDs participate in series of new phenomena and exhibit interesting non-photoluminescent properties. Some of these new findings are now being incorporated into novel assays for gene copy number variation (CNV) studies and DNA methylation analysis with improved quantification resolution. Herein, we provide a comprehensive review on the latest developments of QD based molecular diagnostic platforms in which QD plays a versatile and essential role. PMID:22916072
Magneto-Fluorescent Core-Shell Supernanoparticles
Chen, Ou; Riedemann, Lars; Etoc, Fred; Herrmann, Hendrik; Coppey, Mathieu; Barch, Mariya; Farrar, Christian T.; Zhao, Jing; Bruns, Oliver T.; Wei, He; Guo, Peng; Cui, Jian; Jensen, Russ; Chen, Yue; Harris, Daniel K.; Cordero, Jose M.; Wang, Zhongwu; Jasanoff, Alan; Fukumura, Dai; Reimer, Rudolph; Dahan, Maxime; Jain, Rakesh K.; Bawendi, Moungi G.
2014-01-01
Magneto-fluorescent particles have been recognized as an emerging class of materials that exhibit great potential in advanced applications. However, synthesizing such magneto-fluorescent nanomaterials that simultaneously exhibit uniform and tunable sizes, high magnetic content loading, maximized fluorophore coverage at the surface, and a versatile surface functionality has proven challenging. Here we report a simple approach for co-assembling magnetic nanoparticles with fluorescent quantum dots to form colloidal magneto-fluorescent supernanoparticles. Importantly, these supernanoparticles exhibit a superstructure consisting of a close packed magnetic nanoparticle “core” which is fully surrounded by a “shell” of fluorescent quantum dots. A thin layer of silica-coating provides high colloidal stability and biocompatiblity and a versatile surface functionality. We demonstrate that after surface pegylation, these silica-coated magneto-fluorescent supernanoparticles can be magnetically manipulated inside living cells while being optically tracked. Moreover, our silica-coated magneto-fluorescent supernanoparticles can also serve as an in vivo multi-photon and magnetic resonance dual-modal imaging probe. PMID:25298155
Xu, Kefeng; Chen, Zhonghui; Zhou, Ling; Zheng, Ou; Wu, Xiaoping; Guo, Longhua; Qiu, Bin; Lin, Zhenyu; Chen, Guonan
2015-01-06
A fluorometric method for pyrophosphatase (PPase) activity detection was developed based on click chemistry. Cu(II) can coordinate with pyrophosphate (PPi), the addition of pyrophosphatase (PPase) into the above system can destroy the coordinate compound because PPase catalyzes the hydrolysis of PPi into inorganic phosphate and produces free Cu(II), and free Cu(II) can be reduced by sodium ascorbate (SA) to form Cu(I), which in turn initiates the ligating reaction between nonfluorescent 3-azidocoumarins and terminal alkynes to produce a highly fluorescent triazole complex, based on which, a simple and sensitive turn on fluorometric method for PPase can be developed. The fluorescence intensity of the system has a linear relationship with the logarithm of the PPase concentration in the range of 0.5 and 10 mU with a detection limit down to 0.2 mU (S/N = 3). This method is cost-effective and convenient without any labels or complicated operations. The proposed system was applied to screen the potential PPase inhibitor with high efficiency. The proposed method can be applied to diagnosis of PPase-related diseases.
Gangidi, R R; Metzger, L E
2006-11-01
The purpose of this study was to determine if the ionic calcium content of skim milk could be determined using molecular probes and front-face fluorescence spectroscopy. Current methods for determining ionic calcium are not sensitive, overestimate ionic calcium, or require complex procedures. Molecular probes designed specifically for measuring ionic calcium could potentially be used to determine the ionic calcium content of skim milk. The goal of the current study was to develop foundation methods for future studies to determine ionic calcium directly in skim milk and other dairy products with molecular probes and fluorescence spectroscopy. In this study, the effect of pH on calcium-sensitive fluorescent probe (Rhod-5N and Fluo-5N) performance using various concentrations of skim milk was determined. The pH of diluted skim milk (1.9 to 8.9% skim milk), was adjusted to either 6.2 or 7.0, after which the samples were analyzed with fluorescent probes (1 microM) and front-face fluorescence spectroscopy. The ionic calcium content of each sample was also determined using a calcium ion-selective electrode. The results demonstrated that the ionic calcium content of each sample was highly correlated (R2 > 0.989) with the fluorescence intensities of the probe-calcium adduct using simple linear regression. Higher than suggested ionic calcium contents of 1,207 and 1,973 microM were determined with the probes (Fluo-5N and Rhod-5N) in diluted skim milk with pH 7.0 and 6.2, respectively. The fluorescence intensity of the probe-calcium adduct decreased with a decrease in pH for the same ionic calcium concentration. This study demonstrates that Fluo-5N and Rhod-5N can be used to determine the ionic-calcium content of diluted milk with front-face fluorescence spectroscopy. Furthermore, these probes may also have the potential to determine the ionic calcium content of undiluted skim milk.
[Fluorescence control of dental calculus removal].
Bakhmutov, D N; Gonchukov, S A; Lonkina, T V; Sukhinina, A V
2012-01-01
The main condition of periodontitis prevention is the full calculus removal from the teeth surface. This procedure should be fulfilled without harming adjacent unaffected tooth tissues. Nevertheless the problem of sensitive and precise estimating of tooth-calculus interface exists and potential risk of hard tissue damage remains. In the frames of this work it was shown that fluorescence diagnostics during calculus removal can be successfully used for precise detection of tooth-calculus interface. In so doing the simple implementation of this method free from the necessity of spectrometer using can be employed. Such a simple implementation of calculus detection set-up can be aggregated with the devices of calculus removing (as ultrasonic or laser devices).
Flavel, Benjamin S; Gross, Andrew J; Garrett, David J; Nock, Volker; Downard, Alison J
2010-04-01
A highly versatile method utilizing diazonium salt chemistry has been developed for the fabrication of protein arrays. Conventional ultraviolet mask lithography was used to pattern micrometer sized regions into a commercial photoresist on a highly doped p-type silicon (100) substrate. These patterned regions were used as a template for the electrochemical grafting of the in situ generated p-aminobenzenediazonium cation to form patterns of aminophenyl film on silicon. Immobilization of biomolecules was demonstrated by coupling biotin to the aminophenyl regions followed by reaction with fluorescently labeled avidin and visualization with fluorescence microscopy. This simple patterning strategy is promising for future application in biosensor devices.
Hsieh, Chun-Yu; Wang, Shing-Yaw; Kwan, Aij-Lie; Wu, Hsin-Lung
2008-01-18
Vigabatrin is widely used as an anticonvulsant in the treatment of seizures. Vigabatrin is usually supplied as racemate in formulation, but only the (S)-(+)-enantiomer of vigabatrin is pharmacologically active. A simple and sensitive liquid chromatographic method is described for the separation and quantification of vigabatrin enantiomers. The method is based on derivatizing racemic vigabatrin with a fluorescent chiral reagent (naproxen acyl chloride). The resulting diastereomeric derivatives are highly responsive to a fluorimetric detector (lambda(ex)=230 nm, lambda(em)=350 nm). The lower quantitation limit of the method is attainable at 25 nM for (S)-(+)-vigabatrin or (R)-(-)-vigabatrin with a detection limit of about 2.5 nM (S/N=3 with 10 microl injected). Application of the method to the analysis of vigabatrin in serum of dosed patients proved feasible.
Ohyama, Kaname; Kishikawa, Naoya; Matsuo, Aya; Imazato, Takahiro; Ueki, Yukitaka; Wada, Mitsuhiro; Nakashima, Kenichiro; Kuroda, Naotaka
2014-01-01
A simple and selective HPLC-fluorescence (FL) method with FL probe, 4-[4-(4-dimethylaminophenyl)-5-phenyl-1H-imidazol-2-yl]benzoic acid methyl ester (DAPIM), for simultaneous determination of mercaptalbumin (HMA) and nonmercaptalbumin (HNA1) was developed. After HMA and HNA1 were separated on an ion-exchange column, they were on-line and post-column mixed with DAPIM. The DAPIM-albumin complex produces FL (λex 370nm and λem 510nm); however, DAPIM solution never gives the FL. Based on this mechanism, selective determination of HMA and HNA1 were achieved without any pretreatment and interfering peak. The proposed method was applied to the measurement of HMA and HNA1 in human serum of healthy volunteers and diabetes mellitus patients. Copyright © 2013 Elsevier B.V. All rights reserved.
Horstkotte, Burkhard; Duarte, Carlos M; Cerdà, Víctor
2011-07-15
In this article, a simple, economic, and miniature flow analyzer for ammonium in seawater based on the solenoid micropumps is presented. A single reagent of sodium tetraborate, ortho-phthaldialdehyde (OPA), and sodium sulfite was used and optimized applying the modified SIMPLEX method. A special-made detection cell for fluorescence detection of the reaction product isoindol-1-sulfonat was made and combined with a commercial photomultiplier tube, a long-pass optical filter, and an UV-LED as excitation light source. A LOD down to 13 nmol/L was achieved. The fabrication and application of a miniature reaction coil heating device for reaction rate enhancement is further described. The system featured an injection frequency of 32 h(-1) at average standard deviation of 3%. Copyright © 2011 Elsevier B.V. All rights reserved.
Yeo, Seon-Ju; Huong, Dinh Thi; Hong, Nguyen Ngoc; Li, Chun-Ying; Choi, Kyunghan; Yu, Kyoungsik; Choi, Du-Young; Chong, Chom-Kyu; Choi, Hak Soo; Mallik, Shyam Kumar; Kim, Hak Sung; Sung, Haan Woo; Park, Hyun
2014-01-01
Great efforts have been made to develop robust signal-generating fluorescence materials which will help in improving the rapid diagnostic test (RDT) in terms of sensitivity and quantification. In this study, we developed coumarin-derived dendrimer-based fluorescent immunochromatographic strip test (FICT) assay with enhanced sensitivity as a quantitative diagnostic tool in typical RDT environments. The accuracy of the proposed FICT was compared with that of dot blot immunoassay techniques and conventional RDTs. Through conjugation of coumarin-derived dendrimers with latex beads, fluorescent emission covering broad output spectral ranges was obtained which provided a distinct advantage of easy discrimination of the fluorescent emission of the latex beads with a simple insertion of a long-pass optical filter away from the excitation wavelength. The newly developed FICT assay was able to detect 100 ng/10 μL of influenza A nucleoprotein (NP) antigen within 5 minutes, which corresponded to 2.5-fold higher sensitivity than that of the dot blot immunoassay or conventional RDTs. Moreover, the FICT assay was confirmed to detect at least four avian influenza A subtypes (H5N3, H7N1, H7N7, and H9N2). On applying the FICT to the clinical swab samples infected with respiratory viruses, our FICT assay was confirmed to differentiate influenza H1N1 infection from other respiratory viral diseases. These data demonstrate that the proposed FICT assay is able to detect zoonotic influenza A viruses with a high sensitivity, and it enables the quantitation of the infection intensity by providing the numerical diagnostic values; thus demonstrating enhanced detectability of influenza A viruses.
NASA Astrophysics Data System (ADS)
Dong, Liang; Hou, Changjun; Yang, Mei; Fa, Huanbao; Wu, Huixiang; Shen, Caihong; Huo, Danqun
2016-06-01
Cyanazine residue poses a great threat to human health and its derivatives would remain in soils, natural waters, and other environmental domains for a long time. Herein, a simple, rapid, and ultra-sensitive analytical method for the determination of cyanazine (CZ) based on inner filter effect (IFE) of Au nanoparticles (AuNPs) on the fluorescence of CdTe quantum dots (QDs) is first described in this study. With the presence of citrate-stabilized AuNPs, the fluorescence of GSH-capped CdTe QDs was remarkably quenched by AuNPs via IFE. The fluorescence of the AuNP-CdTe QD system was recovered upon addition of CZ. CZ can adsorb on to the surface of AuNPs due to its cyano group that has good affinity with gold, which could induce the aggregation of AuNPs accompanying color change from red to blue. Thus, the IFE of AuNPs on CdTe QDs was weakened, and the fluorescence intensity of CdTe QDs was recovered accordingly. A good linear correlation for detection of CZ was exhibited from 0.05 to 9 μM, and the detection limit reached 0.1568 μM, which was much lower than the safety limit required by the USA, the UK, and China. In order to probe into the selectivity of AuNPs towards CZ over other pesticides, various frequently used pesticides were mixed with AuNPs. AuNP composite solution shows good selectivity towards CZ among other pesticides. This method was successfully carried out for the assessment of CZ in real samples with satisfactory results, which revealed many advantages such as high sensitivity, low cost, and non-time-consuming compared with traditional methods.
Cheng, Dan; Yu, Mengqun; Fu, Fei; Han, Weiye; Li, Gan; Xie, Jianping; Song, Yang; Swihart, Mark T; Song, Erqun
2016-01-05
Food poisoning and infectious diseases caused by pathogenic bacteria such as Staphylococcus aureus (SA) are serious public health concerns. A method of specific, sensitive, and rapid detection of such bacteria is essential and important. This study presents a strategy that combines aptamer and antibiotic-based dual recognition units with magnetic enrichment and fluorescent detection to achieve specific and sensitive quantification of SA in authentic specimens and in the presence of much higher concentrations of other bacteria. Aptamer-coated magnetic beads (Apt-MB) were employed for specific capture of SA. Vancomycin-stabilized fluorescent gold nanoclusters (AuNCs@Van) were prepared by a simple one-step process and used for sensitive quantification of SA in the range of 32-10(8) cfu/mL with the detection limit of 16 cfu/mL via a fluorescence intensity measurement. And using this strategy, about 70 cfu/mL of SA in complex samples (containing 3 × 10(8) cfu/mL of other different contaminated bacteria) could be successfully detected. In comparison to prior studies, the developed strategy here not only simplifies the preparation procedure of the fluorescent probes (AuNCs@Van) to a great extent but also could sensitively quantify SA in the presence of much higher concentrations of other bacteria directly with good accuracy. Moreover, the aptamer and antibiotic used in this strategy are much less expensive and widely available compared to common-used antibodies, making it cost-effective. This general aptamer- and antibiotic-based dual recognition strategy, combined with magnetic enrichment and fluorescent detection of trace bacteria, shows great potential application in monitoring bacterial food contamination and infectious diseases.
Li, Haiyin; Chang, Jiafu; Hou, Ting; Ge, Lei; Li, Feng
2016-11-01
Reliable, selective and sensitive approaches for trinitrophenol (TNP) detection are highly desirable with respect to national security and environmental protection. Herein, a simple and novel fluorescent strategy for highly sensitive and specific TNP assay has been successfully developed, which is based on the quenching of the fluorescent poly(thymine)-templated copper nanoclusters (DNA-CuNCs), through the synergetic effects of acid induction and electron transfer. Upon the addition of TNP, donor-acceptor complexes between the electron-deficient nitro-groups in TNP and the electron-donating DNA templates are formed, resulting in the close proximity between TNP and CuNCs. Moreover, the acidity of TNP contributes to the pH decrease of the system. These factors combine to dramatically quench the fluorescence of DNA-CuNCs, providing a "signal-off" strategy for TNP sensing. The as-proposed strategy demonstrates high sensitivity for TNP assay, and a detection limit of 0.03μM is obtained, which is lower than those reported by using organic fluorescent materials. More significantly, this approach shows outstanding selectivity over a number of TNP analogues, such as 2,4,6-trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), 2,4-dinitrophenol (DNP), 3-nitrophenol (NP), nitrobenzene (NB), phenol (BP), and toluene (BT). Compared with previous studies, this method does not need complex DNA sequence design, fluorescent dye labeling, or sophisticated organic reactions, rendering the strategy with additional advantages of simplicity and cost-effectiveness. In addition, the as-proposed strategy has been adopted for the detection of TNP in natural water samples, indicating its great potential to be applied in the fields of public safety and environmental monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.
Recent developments of genetically encoded optical sensors for cell biology.
Bolbat, Andrey; Schultz, Carsten
2017-01-01
Optical sensors are powerful tools for live cell research as they permit to follow the location, concentration changes or activities of key cellular players such as lipids, ions and enzymes. Most of the current sensor probes are based on fluorescence which provides great spatial and temporal precision provided that high-end microscopy is used and that the timescale of the event of interest fits the response time of the sensor. Many of the sensors developed in the past 20 years are genetically encoded. There is a diversity of designs leading to simple or sometimes complicated applications for the use in live cells. Genetically encoded sensors began to emerge after the discovery of fluorescent proteins, engineering of their improved optical properties and the manipulation of their structure through application of circular permutation. In this review, we will describe a variety of genetically encoded biosensor concepts, including those for intensiometric and ratiometric sensors based on single fluorescent proteins, Forster resonance energy transfer-based sensors, sensors utilising bioluminescence, sensors using self-labelling SNAP- and CLIP-tags, and finally tetracysteine-based sensors. We focus on the newer developments and discuss the current approaches and techniques for design and application. This will demonstrate the power of using optical sensors in cell biology and will help opening the field to more systematic applications in the future. © 2016 Société Française des Microscopies and Société de Biologie Cellulaire de France. Published by John Wiley & Sons Ltd.
Carbon dot-Au(i)Ag(0) assembly for the construction of an artificial light harvesting system.
Jana, Jayasmita; Aditya, Teresa; Pal, Tarasankar
2018-03-06
Artificial light harvesting systems (LHS) with inorganic counterparts are considered to be robust as well as mechanistically simple, where the system follows the donor-acceptor principle with an unchanged structural pattern. Plasmonic gold or silver nanoparticles are mostly chosen as inorganic counterparts to design artificial LHS. To capitalize on its electron accepting capability, Au(i) has been considered in this work for the synergistic stabilization of a system with intriguingly fluorescing silver(0) clusters produced in situ. Thus a stable fluorescent Au(i)Ag(0) assembly is generated with electron accepting capabilities. On the other hand, carbon dots have evolved as new fluorescent probes due to their unique physicochemical properties. Utilizing the simple electronic behavior of carbon dots, an electronic interaction between the fluorescent Au(i)Ag(0) and a carbon dot has been investigated for the construction of a new artificial light harvesting system. This coinage metal assembly allows surface energy transfer where it acts as an acceptor, while the carbon dot behaves as a good donor. The energy transfer efficiency has been calculated experimentally to be significant (81.3%) and the Au(i)Ag(0)-carbon dot assembly paves the way for efficient artificial LHS.
Dong, Jiang Xue; Gao, Zhong Feng; Zhang, Ying; Li, Bang Lin; Li, Nian Bing; Luo, Hong Qun
2017-05-15
In this paper, a simple sensor platform is presented for highly selective and sensitive detection of dissolved ammonia in aqueous solutions without pretreatment based on temperature gradient headspace single drop microextraction (HS-SDME) technique, and fluorescence and UV-vis spectrophotometry are utilized with the Ag nanoclusters (Ag NCs) functioned by citrate and glutathione as the probe. The sensing mechanism is based on the volatility of ammonia gas and the active response of Ag NCs to pH change caused by the introduction of ammonia. High pH can make the Ag NCs agglomerate and lead to the obvious decrease of fluorescence intensity and absorbance of Ag NCs solution. Moreover, the presented method exhibits a remarkably high selectivity toward dissolved ammonia over most of inorganic ions and amino acid, and shows a good linear range of 10-350μM (0.14-4.9mgNL -1 ) with a low detection limit of 336nM (4.70μgNL -1 ) at a signal-to-noise ratio of 3. In addition, the practical applications of the sensor have been successfully demonstrated by detecting dissolved ammonia in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.
O'Mahony, Fiach C.; Papkovsky, Dmitri B.
2006-01-01
A simple method has been developed for the analysis of aerobic bacteria in complex samples such as broth and food homogenates. It employs commercial phosphorescent oxygen-sensitive probes to monitor oxygen consumption of samples containing bacteria using standard microtiter plates and fluorescence plate readers. As bacteria grow in aqueous medium, at certain points they begin to deplete dissolved oxygen, which is seen as an increase in probe fluorescence above baseline signal. The time required to reach threshold signal is used to either enumerate bacteria based on a predetermined calibration or to assess the effects of various effectors on the growth of test bacteria by comparison with an untreated control. This method allows for the sensitive (down to a single cell), rapid (0.5 to 12 h) enumeration of aerobic bacteria without the need to conduct lengthy (48 to 72 h) and tedious colony counts on agar plates. It also allows for screening a wide range of chemical and environmental samples for their toxicity. These assays have been validated with different bacteria, including Escherichia coli, Micrococcus luteus, and Pseudomonas fluorescens, with the enumeration of total viable counts in broth and industrial food samples (packaged ham, chicken, and mince meat), and comparison with established agar plating and optical-density-at-600-nm assays has been given. PMID:16461677
Casado-Terrones, Silvia; Fernández-Sánchez, Jorge F; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto
2007-06-01
The performance of two homemade fluorescence-induced capillary electrophoresis detectors, one based on light-emitting diode (LED) as the excitation source and a charge-coupled device (CCD) photodetector and the other based on a commercial luminescence spectrometer (Xe lamp) as the excitation source and a photomultiplier tube as a detector, were compared for the determination of fluorescent proteins R-phycoerythrin and B-phycoerythrin. Both devices use commercially available, reasonably priced optical components that can be used by nonexperts. After fine optimization of several optical and separation parameters in both devices, a zone capillary electrophoresis methodology was achieved with 50mM borate buffer (pH 8.4) and 10mM phytic acid for the determination of two phycobiliproteins. Detection limits of 0.50 and 0.64microg/ml for R-phycoerythrin and B-phycoerythrin, respectively, were achieved by using the LED-induced fluorescence capillary electrophoresis (LED-IF-CE) system, and corresponding detection limits of 2.73 and 2.16microg/ml were achieved by using the Xe lamp-IF-CE system. Analytical performance and other parameters, such as cost and potential to miniaturization, are compared for both devices.
NASA Astrophysics Data System (ADS)
Tang, Feng; Pang, Dai-Wen; Chen, Zhi; Shao, Jian-Bo; Xiong, Ling-Hong; Xiang, Yan-Ping; Xiong, Yan; Wu, Kai; Ai, Hong-Wu; Zhang, Hui; Zheng, Xiao-Li; Lv, Jing-Rui; Liu, Wei-Yong; Hu, Hong-Bing; Mei, Hong; Zhang, Zhen; Sun, Hong; Xiang, Yun; Sun, Zi-Yong
2016-02-01
It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance.It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance. Electronic supplementary information (ESI) available: One additional figure (Fig. S1), two additional tables (Tables S1 and S2) and additional information. See DOI: 10.1039/c5nr07424j
NASA Astrophysics Data System (ADS)
Paul, Bijan Kumar; Mahanta, Subrata; Singh, Rupashree Balia; Guchhait, Nikhil
2011-06-01
A structurally simple Schiff base N-benzyl-(3-hydroxy-2-naphthalene) (NBHN32) has been synthesized and characterized by 1H NMR, 13C NMR, and DEPT spectroscopy. The photophysical behaviour of NBHN32 in response to the presence of various transition metal cations has been explored by means of steady-state absorption, emission and time-resolved emission spectroscopy techniques. Efficient through space intramolecular photoinduced electron transfer (PET) between the naphthalene fluorophore and the imine group has been argued for extremely low fluorescence yield of NBHN32 compared to the parent molecule 3-hydroxy-2-naphthaldehyde (HN32) containing the same fluorophore but lacking the receptor moiety. Transition metal ion-induced emission enhancement is thus addressed on the lexicon of perturbation of the PET by the metal ions. Apart from fluorescence enhancement, transition metal ion imparts remarkable shift of the emission maxima of NBHN32, which is another unique aspect on the proposed ability of NBHN32 to function as a fluorescence chemosensor.
Zhou, Yalei; Zhou, Jie; Wang, Feng; Yang, Haifeng
2018-05-01
Particles which bear tumor cell targeting and multimode imaging capabilities are promising in tumor diagnosis and cancer therapy. A simple and versatile method to fabricate gold/polydopamine-Methylene Blue@Bovine Serum Albumin-glutaraldehyde-Transferrin composite particles (Au/PDA-MB@BSA-GA-Tf NPs) for tumor cell targeting and fluorescence (FL) / surface-enhanced Raman scattering (SERS) dual-modal imaging were reported in this work. Polydopamine (PDA) spheres played an important role in gold ion reduction, gold nanoparticle (Au NPs) binding and methylene blue (MB) adsorption, MB were employed as both fluorescence label and Raman reporter. In addition, glutaraldehyde (GA) crosslinked bovine serum albumin (BSA) in the outer layer of Au/PDA-MB nanoparticles can prevent MB from dissociation and leakage. The composite nanoparticles were further conjugated with transferrin (Tf) to target transferrin receptor (TfR)-overexpressed cancer cells. The targeting ability as well as the intracellular location of the probe was investigated through SERS mapping and fluorescence imaging. Their excellent biocompatibility was demonstrated by low cytotoxicity against breast cancer cell (4T1 cell). Copyright © 2018 Elsevier B.V. All rights reserved.
Principal component analysis of dynamic fluorescence images for diagnosis of diabetic vasculopathy
NASA Astrophysics Data System (ADS)
Seo, Jihye; An, Yuri; Lee, Jungsul; Ku, Taeyun; Kang, Yujung; Ahn, Chulwoo; Choi, Chulhee
2016-04-01
Indocyanine green (ICG) fluorescence imaging has been clinically used for noninvasive visualizations of vascular structures. We have previously developed a diagnostic system based on dynamic ICG fluorescence imaging for sensitive detection of vascular disorders. However, because high-dimensional raw data were used, the analysis of the ICG dynamics proved difficult. We used principal component analysis (PCA) in this study to extract important elements without significant loss of information. We examined ICG spatiotemporal profiles and identified critical features related to vascular disorders. PCA time courses of the first three components showed a distinct pattern in diabetic patients. Among the major components, the second principal component (PC2) represented arterial-like features. The explained variance of PC2 in diabetic patients was significantly lower than in normal controls. To visualize the spatial pattern of PCs, pixels were mapped with red, green, and blue channels. The PC2 score showed an inverse pattern between normal controls and diabetic patients. We propose that PC2 can be used as a representative bioimaging marker for the screening of vascular diseases. It may also be useful in simple extractions of arterial-like features.
Pierini, Gastón Darío; Pinto, Victor Hugo A; Maia, Clarissa G C; Fragoso, Wallace D; Reboucas, Julio S; Centurión, María Eugenia; Pistonesi, Marcelo Fabián; Di Nezio, María Susana
2017-11-01
The quantification of zinc in over-the-counter drugs as commercial propolis extracts by molecular fluorescence technique using meso-tetrakis(4-carboxyphenyl)porphyrin (H 2 TCPP 4 ) was developed for the first time. The calibration curve is linear from 6.60 to 100 nmol L -1 of Zn 2+ . The detection and quantification limits were 6.22 nmol L -1 and 19.0 nmol L -1 , respectively. The reproducibility and repeatability calculated as the percentage variation of slopes of seven calibration curves were 6.75% and 4.61%, respectively. Commercial propolis extract samples from four Brazilian states were analyzed and the results (0.329-0.797 mg/100 mL) obtained with this method are in good agreement with that obtained with the Atomic Absorption Spectroscopy (AAS) technique. The method is simple, fast, of low cost and allows the analysis of the samples without pretreatment. Moreover the major advantage is that Zn-porphyrin complex presents fluorescent characteristic promoting the selectivity and sensitivity of the method. Copyright © 2017 John Wiley & Sons, Ltd.
A Simple Visualization of Double Bond Properties: Chemical Reactivity and UV Fluorescence
ERIC Educational Resources Information Center
Grayson, Scott M.
2012-01-01
A simple, easily visualized thin-layer chromatography (TLC) staining experiment is presented that highlights the difference in reactivity between aromatic double bonds and nonaromatic double bonds. Although the stability of aromatic systems is a major theme in organic chemistry, the concept is rarely reinforced "visually" in the undergraduate…
Sun, Yulong; Ip, Philbert; Chakrabartty, Avijit
2017-09-03
Immunofluorescence is a common method used to visualize subcellular compartments and to determine the localization of specific proteins within a tissue sample. A great hindrance to the acquisition of high quality immunofluorescence images is endogenous autofluorescence of the tissue caused by aging pigments such as lipofuscin or by common sample preparation processes such as aldehyde fixation. This protocol describes how background fluorescence can be greatly reduced through photobleaching using white phosphor light emitting diode (LED) arrays prior to treatment with fluorescent probes. The broad-spectrum emission of white phosphor LEDs allow for bleaching of fluorophores across a range of emission peaks. The photobleaching apparatus can be constructed from off-the-shelf components at very low cost and offers an accessible alternative to commercially available chemical quenchers. A photobleaching pre-treatment of the tissue followed by conventional immunofluorescence staining generates images free of background autofluorescence. Compared to established chemical quenchers which reduced probe as well as background signals, photobleaching treatment had no effect on probe fluorescence intensity while it effectively reduced background and lipofuscin fluorescence. Although photobleaching requires more time for pre-treatment, higher intensity LED arrays may be used to reduce photobleaching time. This simple method can potentially be applied to a variety of tissues, particularly postmitotic tissues that accumulate lipofuscin such as the brain and cardiac or skeletal muscles.
In vivo imaging and quantitative monitoring of autophagic flux in tobacco BY-2 cells.
Hanamata, Shigeru; Kurusu, Takamitsu; Okada, Masaaki; Suda, Akiko; Kawamura, Koki; Tsukada, Emi; Kuchitsu, Kazuyuki
2013-01-01
Autophagy has been shown to play essential roles in the growth, development and survival of eukaryotic cells. However, simple methods for quantification and visualization of autophagic flux remain to be developed in living plant cells. Here, we analyzed the autophagic flux in transgenic tobacco BY-2 cell lines expressing fluorescence-tagged NtATG8a as a marker for autophagosome formation. Under sucrose-starved conditions, the number of punctate signals of YFP-NtATG8a increased, and the fluorescence intensity of the cytoplasm and nucleoplasm decreased. Conversely, these changes were not observed in BY-2 cells expressing a C-terminal glycine deletion mutant of the NtATG8a protein (NtATG8aΔG). To monitor the autophagic flux more easily, we generated a transgenic BY-2 cell line expressing NtATG8a fused to a pH-sensitive fluorescent tag, a tandem fusion of the acid-insensitive RFP and the acid-sensitive YFP. In sucrose-rich conditions, both fluorescent signals were detected in the cytoplasm and only weakly in the vacuole. In contrast, under sucrose-starved conditions, the fluorescence intensity of the cytoplasm decreased, and the RFP signal clearly increased in the vacuole, corresponding to the fusion of the autophagosome to the vacuole and translocation of ATG8 from the cytoplasm to the vacuole. Moreover, we introduce a novel simple easy way to monitor the autophagic flux non-invasively by only measuring the ratio of fluorescence of RFP and YFP in the cell suspension using a fluorescent image analyzer without microscopy. The present in vivo quantitative monitoring system for the autophagic flux offers a powerful tool for determining the physiological functions and molecular mechanisms of plant autophagy induced by environmental stimuli.
In vivo imaging and quantitative monitoring of autophagic flux in tobacco BY-2 cells
Hanamata, Shigeru; Kurusu, Takamitsu; Okada, Masaaki; Suda, Akiko; Kawamura, Koki; Tsukada, Emi; Kuchitsu, Kazuyuki
2013-01-01
Autophagy has been shown to play essential roles in the growth, development and survival of eukaryotic cells. However, simple methods for quantification and visualization of autophagic flux remain to be developed in living plant cells. Here, we analyzed the autophagic flux in transgenic tobacco BY-2 cell lines expressing fluorescence-tagged NtATG8a as a marker for autophagosome formation. Under sucrose-starved conditions, the number of punctate signals of YFP-NtATG8a increased, and the fluorescence intensity of the cytoplasm and nucleoplasm decreased. Conversely, these changes were not observed in BY-2 cells expressing a C-terminal glycine deletion mutant of the NtATG8a protein (NtATG8aΔG). To monitor the autophagic flux more easily, we generated a transgenic BY-2 cell line expressing NtATG8a fused to a pH-sensitive fluorescent tag, a tandem fusion of the acid-insensitive RFP and the acid-sensitive YFP. In sucrose-rich conditions, both fluorescent signals were detected in the cytoplasm and only weakly in the vacuole. In contrast, under sucrose-starved conditions, the fluorescence intensity of the cytoplasm decreased, and the RFP signal clearly increased in the vacuole, corresponding to the fusion of the autophagosome to the vacuole and translocation of ATG8 from the cytoplasm to the vacuole. Moreover, we introduce a novel simple easy way to monitor the autophagic flux non-invasively by only measuring the ratio of fluorescence of RFP and YFP in the cell suspension using a fluorescent image analyzer without microscopy. The present in vivo quantitative monitoring system for the autophagic flux offers a powerful tool for determining the physiological functions and molecular mechanisms of plant autophagy induced by environmental stimuli. PMID:23123450
Azadioxatriangulenium: a long fluorescence lifetime fluorophore for large biomolecule binding assay
NASA Astrophysics Data System (ADS)
Just Sørensen, Thomas; Thyrhaug, Erling; Szabelski, Mariusz; Luchowski, Rafal; Gryczynski, Ignacy; Gryczynski, Zygmunt; Laursen, Bo W.
2013-06-01
Of the many optical bioassays available, sensing by fluorescence anisotropy has great advantages as it provides a sensitive, instrumentally simple, ratiometric method of detection. However, it is hampered by a severe limitation, as the emission lifetime of the label needs to be comparable to the correlation lifetime (tumbling time) of the biomolecule which is labelled. For proteins of moderate size this is on the order of 20-200 ns, which due to practical issues currently limits the choice of labels to the dansyl-type dyes and certain aromatic dyes. These have the significant drawback of UV/blue absorption and emission as well as an often significant solvent sensitivity. Here, we report the synthesis and characterization of a new fluorescent label for high molecular weight biomolecule assay based on the azadioxatriangulenium motif. The NHS ester of the long fluorescence lifetime, red-emitting fluorophore: azadioxatriangulenium (ADOTA-NHS) was conjugated to anti-rabbit Immunoglobulin G (antiIgG). The long fluorescence lifetime was exploited to determine the correlation time of the high molecular weight antibody and its complex with rabbit Immunoglobulin G (IgG) with steady-state fluorescence anisotropy and time-resolved methods: solution phase immuno-assay was performed following either steady-state or time-resolved fluorescence anisotropy. By performing a variable temperature experiment it was determined that the binding of the ligand resulted in an increase in correlation time of more than 75%, and an increase in the steady-state anisotropy of 18%. The results show that the triangulenium class of dyes can be used in anisotropy assay to detect binding events involving biomolecules of far larger size than what is possible with most other red-emitting organic dyes.
Ultraviolet signals in birds are special.
Hausmann, Franziska; Arnold, Kathryn E; Marshall, N Justin; Owens, Ian P F
2003-01-07
Recent behavioural experiments have shown that birds use ultraviolet (UV)-reflective and fluorescent plumage as cues in mate choice. It remains controversial, however, whether such UV signals play a special role in sexual communication, or whether they are part of general plumage coloration. We use a comparative approach to test for a general association between sexual signalling and either UV-reflective or fluorescent plumage. Among the species surveyed, 72% have UV colours and there is a significant positive association between UV reflectance and courtship displays. Among parrots (Psittaciformes), 68% of surveyed species have fluorescent plumage, and again there is a strong positive association between courtship displays and fluorescence. These associations are not artefacts of the plumage used in courtship displays, being generally more 'colourful' because there is no association between display and colours lacking UV reflectance or fluorescence. Equally, these associations are not phylogenetic artefacts because all results remain unchanged when families or genera, rather than species, are used as independent data points. We also find that, in parrots, fluorescent plumage is usually found adjacent to UV-reflective plumage. Using a simple visual model to examine one parrot, the budgerigar Melopsittacus undulatus, we show that the juxtaposition of UV-reflective and fluorescent plumage leads to a 25-fold increase in chromatic contrast to the budgerigar's visual system. Taken together, these results suggest that signals based on UV contrast are of special importance in the context of active sexual displays. We review briefly six hypotheses on why this may be the case: suitability for short-range signalling; high contrast with backgrounds; invisibility to predators; exploitation of pre-existing sensory biases; advertisement of feather structure; and amplification of behavioural signals.
Ultraviolet signals in birds are special.
Hausmann, Franziska; Arnold, Kathryn E; Marshall, N Justin; Owens, Ian P F
2003-01-01
Recent behavioural experiments have shown that birds use ultraviolet (UV)-reflective and fluorescent plumage as cues in mate choice. It remains controversial, however, whether such UV signals play a special role in sexual communication, or whether they are part of general plumage coloration. We use a comparative approach to test for a general association between sexual signalling and either UV-reflective or fluorescent plumage. Among the species surveyed, 72% have UV colours and there is a significant positive association between UV reflectance and courtship displays. Among parrots (Psittaciformes), 68% of surveyed species have fluorescent plumage, and again there is a strong positive association between courtship displays and fluorescence. These associations are not artefacts of the plumage used in courtship displays, being generally more 'colourful' because there is no association between display and colours lacking UV reflectance or fluorescence. Equally, these associations are not phylogenetic artefacts because all results remain unchanged when families or genera, rather than species, are used as independent data points. We also find that, in parrots, fluorescent plumage is usually found adjacent to UV-reflective plumage. Using a simple visual model to examine one parrot, the budgerigar Melopsittacus undulatus, we show that the juxtaposition of UV-reflective and fluorescent plumage leads to a 25-fold increase in chromatic contrast to the budgerigar's visual system. Taken together, these results suggest that signals based on UV contrast are of special importance in the context of active sexual displays. We review briefly six hypotheses on why this may be the case: suitability for short-range signalling; high contrast with backgrounds; invisibility to predators; exploitation of pre-existing sensory biases; advertisement of feather structure; and amplification of behavioural signals. PMID:12590772
Ding, Liping; Bai, Yumei; Cao, Yuan; Ren, Guijia; Blanchard, Gary J; Fang, Yu
2014-07-08
The effect of surfactant micelles on the photophysical properties of a cationic bispyrene fluorophore, Py-diIM-Py, was systemically examined. The results from series of measurements including UV-vis absorption, steady-state fluorescence emission, quantum yield, fluorescence lifetime, and time-resolved emission spectra reveal that the cationic fluorophore is only encapsulated by the anionic sodium dodecyl sulfate (SDS) surfactant micelles and not incorporated in the cationic dodecyltrimethylammonium bromide (DTAB) and neutral Triton X-100 (TX100) surfactant micelles. This different fluorophore location in the micellar solutions significantly influences its sensing behavior to various explosives. Fluorescence quenching studies reveal that the simple variation of micellar systems leads to significant changes in the sensitivity and selectivity of the fluorescent sensor to explosives. The sensor exhibits an on-off response to multiple explosives with the highest sensitivity to picric acid (PA) in the anionic SDS micelles. In the cationic DTAB micelles, it displays the highest on-off responses to PYX. Both the sensitivity and selectivity to PYX in the cationic micelles are enhanced compared with that to PA in the anionic micelles. However, the poor encapsulation in the neutral surfactant TX100 micelles leads to fluorescence instability of the fluorophore and fails to function as a sensor system. Time-resolved fluorescence decays in the presence of explosives reveal that the quenching mechanism of two micellar sensor systems to explosives is static in nature. The present work demonstrates that the electrostatic interaction between the cationic fluorophore and differently charged micelles plays a determinative role in adjusting its distribution in micellar solutions, which further influences the sensing behavior of the obtained micellar sensor systems.
Samson, G; Popovic, R
1988-12-01
The phytotoxicity of heavy metals and pesticides was studied by using the fluorescence induction from the alga Dunaliella tertiolecta. The complementary area calculated from the variable fluorescence induction was used as a direct parameter to estimate phytotoxicity. The value of this parameter was affected when algae were treated with different concentrations of mercury, copper, atrazine, DCMU, Dutox, and Soilgard. The toxic effect of these pollutants was estimated by monitoring the decrease in the complementary area, which reflects photosystem II photochemistry. Further, the authors have demonstrated the advantage of using the complementary area as a parameter of phytotoxicity over using variable fluorescence yield. The complementary area of algal fluorescence can be used as a simple and sensitive parameter in the estimation of the phytotoxicity of polluted water.
Controlled synthesis of silver nanostructures stabilized by fluorescent polyarylene ether nitrile
NASA Astrophysics Data System (ADS)
Jia, Kun; Shou, Hongguo; Wang, Pan; Zhou, Xuefei; Liu, Xiaobo
2016-07-01
In this work, the intrinsically fluorescent polyarylene ether nitrile (PEN) was explored to realize the controlled synthesis of fluorescent silver nanostructures with different morphology for the first time. Specifically, it was found that silver nitrate (AgNO3) can be effectively reduced to silver nanoparticles using PEN as both reducing and surface capping agents in N, N-dimethylformamide (DMF). More interestingly, the morphology of obtained fluorescent silver nanostructures can be tuned from nanospheres to nanorods by simple variation of reaction time at 130 °C using a relative PEN:AgNO3 molar concentration ratio of 1:8. Meanwhile, the obtained Ag nanostructures exhibited both localized surface plasmon resonance (LSPR) band and fluorescent emission around 420 nm, which would find potential applications in biochemical sensing and optical devices fields.
Agar/gelatin bilayer gel matrix fabricated by simple thermo-responsive sol-gel transition method.
Wang, Yifeng; Dong, Meng; Guo, Mengmeng; Wang, Xia; Zhou, Jing; Lei, Jian; Guo, Chuanhang; Qin, Chaoran
2017-08-01
We present a simple and environmentally-friendly method to generate an agar/gelatin bilayer gel matrix for further biomedical applications. In this method, the thermally responsive sol-gel transitions of agar and gelatin combined with the different transition temperatures are exquisitely employed to fabricate the agar/gelatin bilayer gel matrix and achieve separate loading for various materials (e.g., drugs, fluorescent materials, and nanoparticles). Importantly, the resulting bilayer gel matrix provides two different biopolymer environments (a polysaccharide environment vs a protein environment) with a well-defined border, which allows the loaded materials in different layers to retain their original properties (e.g., magnetism and fluorescence) and reduce mutual interference. In addition, the loaded materials in the bilayer gel matrix exhibit an interesting release behavior under the control of thermal stimuli. Consequently, the resulting agar/gelatin bilayer gel matrix is a promising candidate for biomedical applications in drug delivery, controlled release, fluorescence labeling, and bio-imaging. Copyright © 2017 Elsevier B.V. All rights reserved.
Nanoparticles speckled by ready-to-conjugate lanthanide complexes for multimodal imaging
NASA Astrophysics Data System (ADS)
Biju, Vasudevanpillai; Hamada, Morihiko; Ono, Kenji; Sugino, Sakiko; Ohnishi, Takashi; Shibu, Edakkattuparambil Sidharth; Yamamura, Shohei; Sawada, Makoto; Nakanishi, Shunsuke; Shigeri, Yasushi; Wakida, Shin-Ichi
2015-09-01
Multimodal and multifunctional contrast agents receive enormous attention in the biomedical imaging field. Such contrast agents are routinely prepared by the incorporation of organic molecules and inorganic nanoparticles (NPs) into host materials such as gold NPs, silica NPs, polymer NPs, and liposomes. Despite their non-cytotoxic nature, the large size of these NPs limits the in vivo distribution and clearance and inflames complex pharmacokinetics, which hinder the regulatory approval for clinical applications. Herein, we report a unique method that combines magnetic resonance imaging (MRI) and fluorescence imaging modalities together in nanoscale entities by the simple, direct and stable conjugation of novel biotinylated coordination complexes of gadolinium(iii) to CdSe/ZnS quantum dots (QD) and terbium(iii) to super paramagnetic iron oxide NPs (SPION) but without any host material. Subsequently, we evaluate the potentials of such lanthanide-speckled fluorescent-magnetic NPs for bioimaging at single-molecule, cell and in vivo levels. The simple preparation and small size make such fluorescent-magnetic NPs promising contrast agents for biomedical imaging.
Hassan, Ahmed Sheikh; Sapin, Anne; Ubrich, Nathalie; Maincent, Philippe; Bolzan, Claire; Leroy, Pierre
2008-10-01
A simple and sensitive high-performance liquid chromatography (HPLC) assay applied to the measurement of ibuprofen in rat plasma has been developed. Two parameters have been investigated to improve ibuprofen detectability using fluorescence detection: variation of mobile phase pH and the use of beta-cyclodextrin (beta-CD). Increasing the pH value from 2.5 to 6.5 and adding 5 mM beta-CD enhanced the fluorescence signal (lambda(exc) = 224 nm; lambda(em) = 290 nm) by 2.5 and 1.3-fold, respectively, when using standards. In the case of plasma samples, only pH variation significantly lowered detection and quantification limits, down to 10 and 35 ng/mL, respectively. Full selectivity was obtained with a single step for plasma treatment, that is, protein precipitation with acidified acetonitrile. The validated method was applied to a pharmacokinetic study of ibuprofen encapsulated in microspheres and subcutaneously administered to rats.
Self-organized fluorescent nanosensors for ratiometric Pb2+ detection.
Arduini, Maria; Mancin, Fabrizio; Tecilla, Paolo; Tonellato, Umberto
2007-07-31
Silica nanoparticles (60 nm diameter) doped with fluorescent dyes and functionalized on the surface with thiol groups have been proved to be efficient fluorescent chemosensors for Pb2+ ions. The particles can detect a 1 microM metal ion concentration with a good selectivity, suffering only interference from Cu2+ ions. Analyte binding sites are provided by the simple grafting of the thiol groups on the nanoparticles. Once bound to the particles surface, the Pb2+ ions quench the emission of the reporting dyes embedded. Sensor performances can be improved by taking advantage of the ease of production of multishell silica particles. On one hand, signaling units can be concentrated in the external shells, allowing a closer interaction with the surface-bound analyte. On the other, a second dye can be buried in the particle core, far enough from the surface to be unaffected by the Pb2+ ions, thus producing a reference signal. In this way, a ratiometric system is easily prepared by simple self-organization of the particle components.
Design and development of a simple UV fluorescence multi-spectral imaging system
NASA Astrophysics Data System (ADS)
Tovar, Carlos; Coker, Zachary; Yakovlev, Vladislav V.
2018-02-01
Healthcare access in low-resource settings is compromised by the availability of affordable and accurate diagnostic equipment. The four primary poverty-related diseases - AIDS, pneumonia, malaria, and tuberculosis - account for approximately 400 million annual deaths worldwide as of 2016 estimates. Current diagnostic procedures for these diseases are prolonged and can become unreliable under various conditions. We present the development of a simple low-cost UV fluorescence multi-spectral imaging system geared towards low resource settings for a variety of biological and in-vitro applications. Fluorescence microscopy serves as a useful diagnostic indicator and imaging tool. The addition of a multi-spectral imaging modality allows for the detection of fluorophores within specific wavelength bands, as well as the distinction between fluorophores possessing overlapping spectra. The developed instrument has the potential for a very diverse range of diagnostic applications in basic biomedical science and biomedical diagnostics and imaging. Performance assessment of the microscope will be validated with a variety of samples ranging from organic compounds to biological samples.
Digital Analysis and Sorting of Fluorescence Lifetime by Flow Cytometry
Houston, Jessica P.; Naivar, Mark A.; Freyer, James P.
2010-01-01
Frequency-domain flow cytometry techniques are combined with modifications to the digital signal processing capabilities of the Open Reconfigurable Cytometric Acquisition System (ORCAS) to analyze fluorescence decay lifetimes and control sorting. Real-time fluorescence lifetime analysis is accomplished by rapidly digitizing correlated, radiofrequency modulated detector signals, implementing Fourier analysis programming with ORCAS’ digital signal processor (DSP) and converting the processed data into standard cytometric list mode data. To systematically test the capabilities of the ORCAS 50 MS/sec analog-to-digital converter (ADC) and our DSP programming, an error analysis was performed using simulated light scatter and fluorescence waveforms (0.5–25 ns simulated lifetime), pulse widths ranging from 2 to 15 µs, and modulation frequencies from 2.5 to 16.667 MHz. The standard deviations of digitally acquired lifetime values ranged from 0.112 to >2 ns, corresponding to errors in actual phase shifts from 0.0142° to 1.6°. The lowest coefficients of variation (<1%) were found for 10-MHz modulated waveforms having pulse widths of 6 µs and simulated lifetimes of 4 ns. Direct comparison of the digital analysis system to a previous analog phase-sensitive flow cytometer demonstrated similar precision and accuracy on measurements of a range of fluorescent microspheres, unstained cells and cells stained with three common fluorophores. Sorting based on fluorescence lifetime was accomplished by adding analog outputs to ORCAS and interfacing with a commercial cell sorter with a radiofrequency modulated solid-state laser. Two populations of fluorescent microspheres with overlapping fluorescence intensities but different lifetimes (2 and 7 ns) were separated to ~98% purity. Overall, the digital signal acquisition and processing methods we introduce present a simple yet robust approach to phase-sensitive measurements in flow cytometry. The ability to simply and inexpensively implement this system on a commercial flow sorter will both allow better dissemination of this technology and better exploit the traditionally underutilized parameter of fluorescence lifetime. PMID:20662090
Fazii, P; Ciancaglini, E; Riario Sforza, G
2002-05-01
The aim of this study was to evaluate a differential staining method to distinguish gram-positive from gram-negative bacteria in fluorescence. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein. With this method, gram-positive bacteria appear yellow and gram-negative bacteria appear green. In view of the importance of a rapid aetiological diagnosis in cases of septicaemia, the differential staining method in fluorescence was compared with Gram stain for the detection of bacteria in blood. Of 5,820 blood cultures entered into the study and identified by the Bactec 9120 fluorescent series instrument (Becton Dickinson Europe, France), 774 were positive. Of the 774 positive cultures, 689 yielded only a single organism. The differential staining method in fluorescence detected 626 of the 689 cultures, while Gram stain detected 468. On the basis of these results, the sensitivity of the differential staining method in fluorescence was 90.9%, while that of Gram stain was 67.9%. The difference between the two methods was statistically significant ( P<0.001). The differential fluorescent staining method was more sensitive than Gram stain in the detection of bacteria in blood cultures during the incubation period. This technique provides a rapid, simple and highly sensitive staining method that can be used in conjunction with subculture methods. Whereas subculture requires an incubation period of 18-24 h, the fluorescent staining technique can detect bacteria on the same day that smears are prepared and examined. The differential fluorescent staining method was also evaluated for its ability to detect microorganisms in cerebrospinal fluid and other clinical specimens. The microorganisms were easily detected, even when bacterial counts in the specimens were low.
Lipowicz, Michelle; Garcia, Antonio
2015-01-01
The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia) for the measurement of sodium ion levels at physiologically-relevant saliva concentrations. The sample and fluorescent reagent solutions are placed in a specially-designed, lightweight device that excludes ambient light and concentrates 470-nm excitation light, from a low-power photodiode, within the sample through non-axially-symmetric refraction. The study found that smartphone cameras and post-image processing quantitated sodium ion concentration in water over the range of 0.5–10 mM, yielding best-fit regressions of the data that agree well with a data regression of microplate luminometer results. The data suggest that fluorescence can be used for the measurement of salivary sodium ion concentrations in low-resource or point-of-care settings. With further fluorescent assay testing, the device may find application in a variety of enzymatic or chemical assays. PMID:28955016
Xu, Yunying; Zhou, Wenjiao; Zhou, Ming; Xiang, Yun; Yuan, Ruo; Chai, Yaqin
2015-02-15
Based on a new signal amplification strategy by the toehold strand displacement-driven cyclic assembly of G-quadruplex DNA, the development of an enzyme-free and non-label aptamer sensing approach for sensitive fluorescent detection of thrombin is described. The target thrombin associates with the corresponding aptamer of the partial dsDNA probes and liberates single stranded initiation sequences, which trigger the toehold strand displacement assembly of two G-quadruplex containing hairpin DNAs. This toehold strand displacement reaction leads to the cyclic reuse of the initiation sequences and the production of DNA assemblies with numerous G-quadruplex structures. The fluorescent dye, N-Methyl mesoporphyrin IX, binds to these G-quadruplex structures and generates significantly amplified fluorescent signals to achieve highly sensitive detection of thrombin down to 5 pM. Besides, this method shows high selectivity towards the target thrombin against other control proteins. The developed thrombin sensing method herein avoids the modification of the probes and the involvement of any enzyme or nanomaterial labels for signal amplification. With the successful demonstration for thrombin detection, our approach can be easily adopted to monitor other target molecules in a simple, low-cost, sensitive and selective way by choosing appropriate aptamer/ligand pairs. Copyright © 2014 Elsevier B.V. All rights reserved.