Sample records for simple laboratory methods

  1. Safety in the Chemical Laboratory: Laboratory Air Quality: Part I. A Concentration Model.

    ERIC Educational Resources Information Center

    Butcher, Samuel S.; And Others

    1985-01-01

    Offers a simple model for estimating vapor concentrations in instructional laboratories. Three methods are described for measuring ventilation rates, and the results of measurements in six laboratories are presented. The model should provide a simple screening tool for evaluating worst-case personal exposures. (JN)

  2. Fostering Elementary School Students' Understanding of Simple Electricity by Combining Simulation and Laboratory Activities

    ERIC Educational Resources Information Center

    Jaakkola, T.; Nurmi, S.

    2008-01-01

    Computer simulations and laboratory activities have been traditionally treated as substitute or competing methods in science teaching. The aim of this experimental study was to investigate if it would be more beneficial to combine simulation and laboratory activities than to use them separately in teaching the concepts of simple electricity. Based…

  3. A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY

    EPA Science Inventory

    Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...

  4. Field and laboratory determination of water-surface elevation and velocity using noncontact measurements

    USGS Publications Warehouse

    Nelson, Jonathan M.; Kinzel, Paul J.; Schmeeckle, Mark Walter; McDonald, Richard R.; Minear, Justin T.

    2016-01-01

    Noncontact methods for measuring water-surface elevation and velocity in laboratory flumes and rivers are presented with examples. Water-surface elevations are measured using an array of acoustic transducers in the laboratory and using laser scanning in field situations. Water-surface velocities are based on using particle image velocimetry or other machine vision techniques on infrared video of the water surface. Using spatial and temporal averaging, results from these methods provide information that can be used to develop estimates of discharge for flows over known bathymetry. Making such estimates requires relating water-surface velocities to vertically averaged velocities; the methods here use standard relations. To examine where these relations break down, laboratory data for flows over simple bumps of three amplitudes are evaluated. As anticipated, discharges determined from surface information can have large errors where nonhydrostatic effects are large. In addition to investigating and characterizing this potential error in estimating discharge, a simple method for correction of the issue is presented. With a simple correction based on bed gradient along the flow direction, remotely sensed estimates of discharge appear to be viable.

  5. DO TIE LABORATORY BASED METHODS REALLY REFLECT FIELD CONDITIONS

    EPA Science Inventory

    Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both interstitial waters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question ...

  6. Simple & Rapid Generation of Complex DNA Profiles for the Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Kass, David H.

    2007-01-01

    Deoxyribonucleic acid (DNA) profiles can be generated by a variety of techniques incorporating different types of DNA markers. Simple methods are commonly utilized in the undergraduate laboratory, but with certain drawbacks. In this article, the author presents an advancement of the "Alu" dimorphism technique involving two tetraplex polymerase…

  7. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    ERIC Educational Resources Information Center

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  8. DO TIE LABORATORY BASED ASSESSMENT METHODS REALLY PREDICT FIELD EFFECTS?

    EPA Science Inventory

    Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both porewaters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question of whethe...

  9. Do Toxicity Identification and Evaluation Laboratory-Based Methods Reflect Causes of Field Impairment?

    EPA Science Inventory

    Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both interstitial waters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question ...

  10. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.

    PubMed

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.

  11. Analysis of pre-service physics teacher skills designing simple physics experiments based technology

    NASA Astrophysics Data System (ADS)

    Susilawati; Huda, C.; Kurniawan, W.; Masturi; Khoiri, N.

    2018-03-01

    Pre-service physics teacher skill in designing simple experiment set is very important in adding understanding of student concept and practicing scientific skill in laboratory. This study describes the skills of physics students in designing simple experiments based technologicall. The experimental design stages include simple tool design and sensor modification. The research method used is descriptive method with the number of research samples 25 students and 5 variations of simple physics experimental design. Based on the results of interviews and observations obtained the results of pre-service physics teacher skill analysis in designing simple experimental physics charged technology is good. Based on observation result, pre-service physics teacher skill in designing simple experiment is good while modification and sensor application are still not good. This suggests that pre-service physics teacher still need a lot of practice and do experiments in designing physics experiments using sensor modifications. Based on the interview result, it is found that students have high enough motivation to perform laboratory activities actively and students have high curiosity to be skilled at making simple practicum tool for physics experiment.

  12. A RAPID DNA EXTRACTION METHOD FOR PCR IDENTIFICATION OF FUNGAL INDOOR AIR CONTAMINANTS

    EPA Science Inventory

    Following air sampling, fungal DNA needs to be extracted and purified to a state suitable for laboratory use. Our laboratory has developed a simple method of extraction and purification of fungal DNA appropriate for enzymatic manipulation and polymerase chain reaction (PCR) appli...

  13. An Efficient, Simple, and Noninvasive Procedure for Genotyping Aquatic and Nonaquatic Laboratory Animals.

    PubMed

    Okada, Morihiro; Miller, Thomas C; Roediger, Julia; Shi, Yun-Bo; Schech, Joseph Mat

    2017-09-01

    Various animal models are indispensible in biomedical research. Increasing awareness and regulations have prompted the adaptation of more humane approaches in the use of laboratory animals. With the development of easier and faster methodologies to generate genetically altered animals, convenient and humane methods to genotype these animals are important for research involving such animals. Here, we report skin swabbing as a simple and noninvasive method for extracting genomic DNA from mice and frogs for genotyping. We show that this method is highly reliable and suitable for both immature and adult animals. Our approach allows a simpler and more humane approach for genotyping vertebrate animals.

  14. Flotation of Mineral and Dyes: A Laboratory Experiment for Separation Method Molecular Hitchhikers

    ERIC Educational Resources Information Center

    Rappon, Tim; Sylvestre, Jarrett A.; Rappon, Manit

    2016-01-01

    Flotation as a method of separation is widely researched and is applied in many industries. It has been used to address a wide range of environmental issues including treatment of wastewater, recovery of heavy metals for recycling, extraction of minerals in mining, and so forth. This laboratory attempts to show how such a simple method can be used…

  15. The Implementation of Problem-Solving Based Laboratory Activities to Teach the Concept of Simple Harmonic Motion in Senior High School

    NASA Astrophysics Data System (ADS)

    Iradat, R. D.; Alatas, F.

    2017-09-01

    Simple harmonic motion is considered as a relatively complex concept to be understood by students. This study attempts to implement laboratory activities that focus on solving contextual problems related to the concept. A group of senior high school students participated in this pre-experimental method from a group’s pretest-posttest research design. Laboratory activities have had a positive impact on improving students’ scientific skills, such as, formulating goals, conducting experiments, applying laboratory tools, and collecting data. Therefore this study has added to the theoretical and practical knowledge that needs to be considered to teach better complicated concepts in physics learning.

  16. A Laboratory Experiment for Rapid Determination of the Stability of Vitamin C

    ERIC Educational Resources Information Center

    Adem, Seid M.; Lueng, Sam H.; Elles, Lisa M. Sharpe; Shaver, Lee Alan

    2016-01-01

    Experiments in laboratory manuals intended for general, organic, and biological (GOB) chemistry laboratories include few opportunities for students to engage in instrumental methods of analysis. Many of these students seek careers in modern health-related fields where experience in spectroscopic techniques would be beneficial. A simple, rapid,…

  17. Software validation applied to spreadsheets used in laboratories working under ISO/IEC 17025

    NASA Astrophysics Data System (ADS)

    Banegas, J. M.; Orué, M. W.

    2016-07-01

    Several documents deal with software validation. Nevertheless, more are too complex to be applied to validate spreadsheets - surely the most used software in laboratories working under ISO/IEC 17025. The method proposed in this work is intended to be directly applied to validate spreadsheets. It includes a systematic way to document requirements, operational aspects regarding to validation, and a simple method to keep records of validation results and modifications history. This method is actually being used in an accredited calibration laboratory, showing to be practical and efficient.

  18. A centrifugal method for the evaluation of polymer membranes for reverse osmosis

    NASA Technical Reports Server (NTRS)

    Hollahan, J. R.; Wydeven, T.; Mccullough, R. P.

    1973-01-01

    A rapid and simple method employing the laboratory centrifuge shows promise for evaluation of membrane performance during reverse osmosis. Results are presented for cellulose acetate membranes for rejection of salt and urea dissolved solids. Implications of the study are to rapid screening of membrane performance, use in laboratories with limited facilities, and possible space waste water purification.

  19. Teaching Chromatography Using Virtual Laboratory Exercises

    ERIC Educational Resources Information Center

    Stone, David C.

    2007-01-01

    Though deceptively simple to teach, chromatography presents many nuances and complex interactions that challenge both student and instructor. Time and instrumentation provide major obstacles to a thorough examination of these details in the laboratory. Modern chromatographic method-development software provides an opportunity to overcome this,…

  20. Filtration Isolation of Nucleic Acids: A Simple and Rapid DNA Extraction Method.

    PubMed

    McFall, Sally M; Neto, Mário F; Reed, Jennifer L; Wagner, Robin L

    2016-08-06

    FINA, filtration isolation of nucleic acids, is a novel extraction method which utilizes vertical filtration via a separation membrane and absorbent pad to extract cellular DNA from whole blood in less than 2 min. The blood specimen is treated with detergent, mixed briefly and applied by pipet to the separation membrane. The lysate wicks into the blotting pad due to capillary action, capturing the genomic DNA on the surface of the separation membrane. The extracted DNA is retained on the membrane during a simple wash step wherein PCR inhibitors are wicked into the absorbent blotting pad. The membrane containing the entrapped DNA is then added to the PCR reaction without further purification. This simple method does not require laboratory equipment and can be easily implemented with inexpensive laboratory supplies. Here we describe a protocol for highly sensitive detection and quantitation of HIV-1 proviral DNA from 100 µl whole blood as a model for early infant diagnosis of HIV that could readily be adapted to other genetic targets.

  1. FIELD VALIDATION OF SEDIMENT TOXCITY IDENTIFCATION AND EVALUATION METHODS

    EPA Science Inventory

    Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both porewaters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question of whethe...

  2. Rapid, simple and inexpensive production of custom 3D printed equipment for large-volume fluorescence microscopy

    PubMed Central

    Tyson, Adam L.; Hilton, Stephen T.; Andreae, Laura C.

    2015-01-01

    The cost of 3D printing has reduced dramatically over the last few years and is now within reach of many scientific laboratories. This work presents an example of how 3D printing can be applied to the development of custom laboratory equipment that is specifically adapted for use with the novel brain tissue clearing technique, CLARITY. A simple, freely available online software tool was used, along with consumer-grade equipment, to produce a brain slicing chamber and a combined antibody staining and imaging chamber. Using standard 3D printers we were able to produce research-grade parts in an iterative manner at a fraction of the cost of commercial equipment. 3D printing provides a reproducible, flexible, simple and cost-effective method for researchers to produce the equipment needed to quickly adopt new methods. PMID:25797056

  3. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    PubMed

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  4. An Undergraduate Laboratory Experiment Using a Simple Photoassisted Fuel Cell to Remediate Simulated Wastewater

    ERIC Educational Resources Information Center

    Touati, Faiza; McGuigan, Kevin G.; Cassidy, John

    2007-01-01

    A simple method of casting with a Ti[O[subscript]2]/polyvinylchloride (PVC) composite layer was used to describe the behavior of coated electrodes. The system demonstrated that even with low energy light sources, an enhancement of the oxidation efficiency is possible.

  5. Simple Analysis of Historical Lime Mortars

    ERIC Educational Resources Information Center

    Pires, Joa~o

    2015-01-01

    A laboratory experiment is described in which a simple characterization of a historical lime mortar is made by the determination of its approximate composition by a gravimetric method. Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD) are also used for the qualitative characterization of the lime mortar components. These…

  6. A Laboratory Exercise with Related Rates.

    ERIC Educational Resources Information Center

    Sworder, Steven C.

    A laboratory experiment, based on a simple electric circuit that can be used to demonstrate the existence of real-world "related rates" problems, is outlined and an equation for voltage across the capacitor terminals during discharge is derived. The necessary materials, setup methods, and experimental problems are described. A student laboratory…

  7. Validating the Collision-Dominated Child-Langmuir Law for a DC Discharge Cathode Sheath in an Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Lisovskiy, V.; Yegorenkov, V.

    2009-01-01

    In this paper, we propose a simple method of observing the collision-dominated Child-Langmuir law in the course of an undergraduate laboratory work devoted to studying the properties of gas discharges. To this end we employ the dc gas discharge whose properties are studied in sufficient detail. The undergraduate laboratory work itself is reduced…

  8. A simple, multidimensional approach to high-throughput discovery of catalytic reactions.

    PubMed

    Robbins, Daniel W; Hartwig, John F

    2011-09-09

    Transition metal complexes catalyze many important reactions that are employed in medicine, materials science, and energy production. Although high-throughput methods for the discovery of catalysts that would mirror related approaches for the discovery of medicinally active compounds have been the focus of much attention, these methods have not been sufficiently general or accessible to typical synthetic laboratories to be adopted widely. We report a method to evaluate a broad range of catalysts for potential coupling reactions with the use of simple laboratory equipment. Specifically, we screen an array of catalysts and ligands with a diverse mixture of substrates and then use mass spectrometry to identify reaction products that, by design, exceed the mass of any single substrate. With this method, we discovered a copper-catalyzed alkyne hydroamination and two nickel-catalyzed hydroarylation reactions, each of which displays excellent functional-group tolerance.

  9. Noncontact methods for measuring water-surface elevations and velocities in rivers: Implications for depth and discharge extraction

    USGS Publications Warehouse

    Nelson, Jonathan M.; Kinzel, Paul J.; McDonald, Richard R.; Schmeeckle, Mark

    2016-01-01

    Recently developed optical and videographic methods for measuring water-surface properties in a noninvasive manner hold great promise for extracting river hydraulic and bathymetric information. This paper describes such a technique, concentrating on the method of infrared videog- raphy for measuring surface velocities and both acoustic (laboratory-based) and laser-scanning (field-based) techniques for measuring water-surface elevations. In ideal laboratory situations with simple flows, appropriate spatial and temporal averaging results in accurate water-surface elevations and water-surface velocities. In test cases, this accuracy is sufficient to allow direct inversion of the governing equations of motion to produce estimates of depth and discharge. Unlike other optical techniques for determining local depth that rely on transmissivity of the water column (bathymetric lidar, multi/hyperspectral correlation), this method uses only water-surface information, so even deep and/or turbid flows can be investigated. However, significant errors arise in areas of nonhydrostatic spatial accelerations, such as those associated with flow over bedforms or other relatively steep obstacles. Using laboratory measurements for test cases, the cause of these errors is examined and both a simple semi-empirical method and computational results are presented that can potentially reduce bathymetric inversion errors.

  10. Measuring Plant Water Status: A Simple Method for Investigative Laboratories.

    ERIC Educational Resources Information Center

    Mansfield, Donald H.; Anderson, Jay E.

    1980-01-01

    Describes a method suitable for quantitative studies of plant water status conducted by high school or college students and the calculation of the relative water content (RWC) of a plant. Materials, methods, procedures, and results are discussed, with sample data figures provided. (CS)

  11. Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites

    PubMed Central

    Lucchi, Naomi W.; Gaye, Marie; Diallo, Mammadou Alpha; Goldman, Ira F.; Ljolje, Dragan; Deme, Awa Bineta; Badiane, Aida; Ndiaye, Yaye Die; Barnwell, John W.; Udhayakumar, Venkatachalam; Ndiaye, Daouda

    2016-01-01

    Isothermal nucleic acid amplification assays such as the loop mediated isothermal amplification (LAMP), are well suited for field use as they do not require thermal cyclers to amplify the DNA. To further facilitate the use of LAMP assays in remote settings, simpler sample preparation methods and lyophilized reagents are required. The performance of a commercial malaria LAMP assay (Illumigene Malaria LAMP) was evaluated using two sample preparation workflows (simple filtration prep (SFP)) and gravity-driven filtration prep (GFP)) and pre-dispensed lyophilized reagents. Laboratory and clinical samples were tested in a field laboratory in Senegal and the results independently confirmed in a reference laboratory in the U.S.A. The Illumigene Malaria LAMP assay was easily implemented in the clinical laboratory and gave similar results to a real-time PCR reference test with limits of detection of ≤2.0 parasites/μl depending on the sample preparation method used. This assay reliably detected Plasmodium sp. parasites in a simple low-tech format, providing a much needed alternative to the more complex molecular tests for malaria diagnosis. PMID:27827432

  12. A simple method for fabricating microwire tetrode with sufficient rigidity and integrity without a heat-fusing process.

    PubMed

    Liao, Yi-Fang; Tsai, Meng-Li; Yen, Chen-Tung; Cheng, Chiung-Hsiang

    2011-02-15

    Heat-fusing is a common process for fabricating microwire tetrodes. However, it is time-consuming, and the high-temperature treatment can easily cause the insulation of the microwire to overheat leading to short circuits. We herein provide a simple, fast method to fabricate microwire tetrodes without the heat-fusion process. By increasing the twisting density, we were able to fabricate tetrodes with good rigidity and integrity. This kind of tetrode showed good recording quality, penetrated the brain surface easily, and remained intact after chronic implantation. This method requires only general laboratory tools and is relatively simple even for inexperienced workers. © 2010 Elsevier B.V. All rights reserved.

  13. A simple algorithm for quantifying DNA methylation levels on multiple independent CpG sites in bisulfite genomic sequencing electropherograms.

    PubMed

    Leakey, Tatiana I; Zielinski, Jerzy; Siegfried, Rachel N; Siegel, Eric R; Fan, Chun-Yang; Cooney, Craig A

    2008-06-01

    DNA methylation at cytosines is a widely studied epigenetic modification. Methylation is commonly detected using bisulfite modification of DNA followed by PCR and additional techniques such as restriction digestion or sequencing. These additional techniques are either laborious, require specialized equipment, or are not quantitative. Here we describe a simple algorithm that yields quantitative results from analysis of conventional four-dye-trace sequencing. We call this method Mquant and we compare it with the established laboratory method of combined bisulfite restriction assay (COBRA). This analysis of sequencing electropherograms provides a simple, easily applied method to quantify DNA methylation at specific CpG sites.

  14. Some Insights Regarding a Popular Introductory Gas Law Experiment

    ERIC Educational Resources Information Center

    DePierro, Ed; Garafalo, Fred

    2005-01-01

    The Dumas method provides a relatively simple way to determine the molar mass of volatile chemical compounds. A potential source of error in the Dumas molar mass method as it is often practiced in introductory chemistry laboratories is reported.

  15. Simple Flame Test Techniques Using Cotton Swabs

    ERIC Educational Resources Information Center

    Sanger, Michael J.; Phelps, Amy J.; Banks, Catherine

    2004-01-01

    Three alternative methods for performing flame tests using cheaply and easily available cotton swabs are described. These flame tests are useful for chemical demonstrations or laboratory experiments because they are quick and easy to perform with easy cleanup and disposal methods.

  16. Simple method to detect triacylglycerol biosynthesis in a yeast-based recombinant system

    USDA-ARS?s Scientific Manuscript database

    Standard methods to quantify the activity of triacylglycerol (TAG) synthesizing enzymes DGAT and PDAT (TAG-SE) require a sensitive but rather arduous laboratory assay based on radio-labeled substrates. Here we describe two straightforward methods to detect TAG production in baker’s yeast Saccharomyc...

  17. A Simplified and Inexpensive Method for Measuring Dissolved Oxygen in Water.

    ERIC Educational Resources Information Center

    Austin, John

    1983-01-01

    A modified Winkler method for determining dissolved oxygen in water is described. The method does not require use of a burette or starch indicator, is simple and inexpensive and can be used in the field or laboratory. Reagents/apparatus needed and specific procedures are included. (JN)

  18. Prussian Blue Coated Electrode as a Sensor for Electroinactive Cations in Aqueous Solutions

    ERIC Educational Resources Information Center

    Byrd, Houston; Chapman, Blake E.; Talley, Christopher L.

    2013-01-01

    Prussian Blue (PB) is an excellent material as a sensor for electroinactive cations because of its electrochemical behavior and its zeolytic character. A simple 3-h laboratory designed for a quantitative analysis or an instrumental methods course is reported. This laboratory studies the transport of various cations into a PB-modified electrode…

  19. The Measurement of the Specific Latent Heat of Fusion of Ice: Two Improved Methods.

    ERIC Educational Resources Information Center

    Mak, S. Y.; Chun, C. K. W.

    2000-01-01

    Suggests two methods for measuring the specific latent heat of ice fusion for high school physics laboratories. The first method is an ice calorimeter which is made from simple materials. The second method improves the thermal contact and allows for a more accurate measurement. Lists instructions for both methods. (Author/YDS)

  20. DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.

    2004-03-24

    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNAmore » populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.« less

  1. Fabrication of a Paper-Based Microfluidic Device to Readily Determine Nitrite Ion Concentration by Simple Colorimetric Assay

    ERIC Educational Resources Information Center

    Wang, Bo; Lin, Zhiqiang; Wang, Min

    2015-01-01

    Paper-based microfluidic devices (µPAD) are a burgeoning platform of microfluidic analysis technology. The method described herein is for use in undergraduate and high school chemistry laboratories. A simple and convenient µPAD was fabricated by easy patterning of filter paper using a permanent marker pen. The usefulness of the device was…

  2. Isolation of bacteriophages from air using vacuum filtration technique: an improved and novel method.

    PubMed

    Magare, B; Nair, A; Khairnar, K

    2017-10-01

    Development of a simple and economical air sampler for isolation and enrichment of bacteriophages from air samples. A vacuum filtration unit with simple modifications was used for isolation of bacteriophages from air sampled in the lavatory. Air was sampled at the rate of 62 l min -1 by bubbling into Mcllvaine buffer for 30 min, which was used as bacteriophage solution for enrichment and plaque assessment against individual hosts. Alternatively, the aforementioned phage solution was enriched using a host consortium before plaque assessment. Phages were isolated in the range of 1-12 PFU per ml by the first method, whereas enrichment with host consortium gave phages around 10- to 1000-folds higher in number. Combining with established enrichment method, an improvement of about 10 times in phage isolation efficiency was attained. The method is very useful for studying the natural bacteriophages of air, requiring only a basic microbiological laboratory setup making it simple and economical. This study brings out a simple, economical air sampler for assessing air bacteriophages that can be employed by any microbial laboratory. Although various methods are available for studying bacteriophages in water and soil, very limited are available for air. To the best of our knowledge, the method developed in this study is unique in its design and concept for studying bacteriophages in air. The sampler is sterilizable by autoclaving and maintains a healthy rate of airflow provided by conventional vacuum pumps. The use of a nonspecific 'trapping solution' allows for the qualitative and quantitative study of air bacteriophages. © 2017 The Society for Applied Microbiology.

  3. Tenax extraction as a simple approach to improve environmental risk assessments.

    PubMed

    Harwood, Amanda D; Nutile, Samuel A; Landrum, Peter F; Lydy, Michael J

    2015-07-01

    It is well documented that using exhaustive chemical extractions is not an effective means of assessing exposure of hydrophobic organic compounds in sediments and that bioavailability-based techniques are an improvement over traditional methods. One technique that has shown special promise as a method for assessing the bioavailability of hydrophobic organic compounds in sediment is the use of Tenax-extractable concentrations. A 6-h or 24-h single-point Tenax-extractable concentration correlates to both bioaccumulation and toxicity. This method has demonstrated effectiveness for several hydrophobic organic compounds in various organisms under both field and laboratory conditions. In addition, a Tenax bioaccumulation model was developed for multiple compounds relating 24-h Tenax-extractable concentrations to oligochaete tissue concentrations exposed in both the laboratory and field. This model has demonstrated predictive capacity for additional compounds and species. Use of Tenax-extractable concentrations to estimate exposure is rapid, simple, straightforward, and relatively inexpensive, as well as accurate. Therefore, this method would be an invaluable tool if implemented in risk assessments. © 2015 SETAC.

  4. Chocolate--A Sweet Conundrum.

    ERIC Educational Resources Information Center

    Beckett, Stephen

    1988-01-01

    Presented is a brief history of manufacturing chocolate and an outline of production methods. Describes laboratory techniques used to monitor liquid chocolate viscosity. Discusses a simple experiment which can be performed in the classroom. (Author/CW)

  5. Review of the Agard S&M panel evaluation program of the NASA-Lewis 'SRP' approach to high-temperature LCF life prediction. [Strainrange Partitioning for Low Cycle Fatigue

    NASA Technical Reports Server (NTRS)

    Hirschberg, M. H.

    1978-01-01

    Twenty laboratories in six countries participated in this program, each testing its own materials of interest under its own laboratory conditions. In this way the results obtained provided validation of the Strainrange Partitioning (SRP) method for a wide range of materials and insured maximum usefulness to each of the participating laboratories. The first, very necessary step in the evaluation of any life prediction approach - assessing the ability of the method to predict life of simple laboratory specimens subjected to complex loading, was thereby taken. The culmination of this program was the Specialists Meeting that was held in Aalborg, Denmark in April of 1978. At that meeting the various investigators shared their findings, thus providing the basis for an in-depth evaluation of the SRP method. While the results were variable from laboratory to laboratory, most investigators agreed that the SRP method was a significant step toward life prediction in the presence of high temperature and cyclic stresses.

  6. New Approaches to Data Acquisitions in a Torsion Pendulum Experiment

    ERIC Educational Resources Information Center

    Jiang, Daya; Xiao, Jinghua; Li, Haihong; Dai, Qionglin

    2007-01-01

    In this paper, two simple non-contact and cost-effective methods to acquire data in the student laboratory are applied to investigate the motion of a torsion pendulum. The first method is based on a Hall sensor, while the second makes use of an optical mouse.

  7. Detection of fragments from internal insects in wheat samples using a laboratory entoleter

    USDA-ARS?s Scientific Manuscript database

    A simple, rapid method was developed for estimating the number of insect fragments in flour caused by hidden, internal-feeding insects in whole grains during storage. The method uses a small mechanical rotary device (entoleter), which accelerates whole wheat kernels to high speeds and projects them...

  8. A simple pore water hydrogen diffusion syringe sampler

    USGS Publications Warehouse

    Vroblesky, D.A.; Chapelle, F.H.; Bradley, P.M.

    2007-01-01

    Molecular hydrogen (H2) is an important intermediate product and electron donor in microbial metabolism. Concentrations of dissolved H 2 are often diagnostic of the predominant terminal electron-accepting processes in ground water systems or aquatic sediments. H2 concentrations are routinely measured in ground water monitoring wells but are rarely measured in saturated aquatic sediments due to a lack of simple and practical sampling methods. This report describes the design and development (including laboratory and field testing) of a simple, syringe-based H 2 sampler in (1) saturated, riparian sediments, (2) surface water bed sediments, and (3) packed intervals of a fractured bedrock borehole that are inaccessible by standard pumped methods. ?? 2007 National Ground Water Association.

  9. Spectrophotometric Method for the Determination of Two Coformulated Drugs with Highly Different Concentrations. Application on Vildagliptin and Metformin Hydrochloride

    NASA Astrophysics Data System (ADS)

    Zaazaa, H. E.; Elzanfaly, E. S.; Soudi, A. T.; Salem, M. Y.

    2016-03-01

    A new smart simple validated spectrophotometric method was developed for the determination of two drugs one of which is in a very low concentration compared to the other. The method is based on spiking and dilution then simple mathematical manipulation of the absorbance spectra. This method was applied for the determination of a binary mixture of vildagliptin and metformin hydrochloride in the ratio 50:850 in laboratory prepared mixtures containing both drugs in this ratio and in pharmaceutical dosage form with good recoveries. The developed method was validated according to ICH guidelines and can be used for routine quality control testing.

  10. Rapid and simple method for binder oxidation aging

    DOT National Transportation Integrated Search

    1999-08-01

    The last 10 years have seen an ever-increasing use of microwave radiation (dielectric heating, in-situ heating) especially in organic synthetic research, the undergraduate laboratory, and industrial production. Scientific microwave instruments are no...

  11. The Development of a Novel, Validated, Rapid and Simple Method for the Detection of Sarcocystis fayeri in Horse Meat in the Sanitary Control Setting.

    PubMed

    Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro

    2016-01-01

    Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.

  12. Comparative Validation of Five Quantitative Rapid Test Kits for the Analysis of Salt Iodine Content: Laboratory Performance, User- and Field-Friendliness

    PubMed Central

    Rohner, Fabian; Kangambèga, Marcelline O.; Khan, Noor; Kargougou, Robert; Garnier, Denis; Sanou, Ibrahima; Ouaro, Bertine D.; Petry, Nicolai; Wirth, James P.; Jooste, Pieter

    2015-01-01

    Background Iodine deficiency has important health and development consequences and the introduction of iodized salt as national programs has been a great public health success in the past decades. To render national salt iodization programs sustainable and ensure adequate iodization levels, simple methods to quantitatively assess whether salt is adequately iodized are required. Several methods claim to be simple and reliable, and are available on the market or are in development. Objective This work has validated the currently available quantitative rapid test kits (quantRTK) in a comparative manner for both their laboratory performance and ease of use in field settings. Methods Laboratory performance parameters (linearity, detection and quantification limit, intra- and inter-assay imprecision) were conducted on 5 quantRTK. We assessed inter-operator imprecision using salt of different quality along with the comparison of 59 salt samples from across the globe; measurements were made both in a laboratory and a field setting by technicians and non-technicians. Results from the quantRTK were compared against iodometric titration for validity. An ‘ease-of-use’ rating system was developed to identify the most suitable quantRTK for a given task. Results Most of the devices showed acceptable laboratory performance, but for some of the devices, use by non-technicians revealed poorer performance when working in a routine manner. Of the quantRTK tested, the iCheck® and I-Reader® showed most consistent performance and ease of use, and a newly developed paper-based method (saltPAD) holds promise if further developed. Conclusions User- and field-friendly devices are now available and the most appropriate quantRTK can be selected depending on the number of samples and the budget available. PMID:26401655

  13. Comparison of a New Cobinamide-Based Method to a Standard Laboratory Method for Measuring Cyanide in Human Blood

    PubMed Central

    Swezey, Robert; Shinn, Walter; Green, Carol; Drover, David R.; Hammer, Gregory B.; Schulman, Scott R.; Zajicek, Anne; Jett, David A.; Boss, Gerry R.

    2013-01-01

    Most hospital laboratories do not measure blood cyanide concentrations, and samples must be sent to reference laboratories. A simple method is needed for measuring cyanide in hospitals. The authors previously developed a method to quantify cyanide based on the high binding affinity of the vitamin B12 analog, cobinamide, for cyanide and a major spectral change observed for cyanide-bound cobinamide. This method is now validated in human blood, and the findings include a mean inter-assay accuracy of 99.1%, precision of 8.75% and a lower limit of quantification of 3.27 µM cyanide. The method was applied to blood samples from children treated with sodium nitroprusside and it yielded measurable results in 88 of 172 samples (51%), whereas the reference laboratory yielded results in only 19 samples (11%). In all 19 samples, the cobinamide-based method also yielded measurable results. The two methods showed reasonable agreement when analyzed by linear regression, but not when analyzed by a standard error of the estimate or paired t-test. Differences in results between the two methods may be because samples were assayed at different times on different sample types. The cobinamide-based method is applicable to human blood, and can be used in hospital laboratories and emergency rooms. PMID:23653045

  14. Building Diversified Multiple Trees for classification in high dimensional noisy biomedical data.

    PubMed

    Li, Jiuyong; Liu, Lin; Liu, Jixue; Green, Ryan

    2017-12-01

    It is common that a trained classification model is applied to the operating data that is deviated from the training data because of noise. This paper will test an ensemble method, Diversified Multiple Tree (DMT), on its capability for classifying instances in a new laboratory using the classifier built on the instances of another laboratory. DMT is tested on three real world biomedical data sets from different laboratories in comparison with four benchmark ensemble methods, AdaBoost, Bagging, Random Forests, and Random Trees. Experiments have also been conducted on studying the limitation of DMT and its possible variations. Experimental results show that DMT is significantly more accurate than other benchmark ensemble classifiers on classifying new instances of a different laboratory from the laboratory where instances are used to build the classifier. This paper demonstrates that an ensemble classifier, DMT, is more robust in classifying noisy data than other widely used ensemble methods. DMT works on the data set that supports multiple simple trees.

  15. Facile generation of cell microarrays using vacuum degassing and coverslip sweeping.

    PubMed

    Wang, Min S; Luo, Zhen; Cherukuri, Sundar; Nitin, Nitin

    2014-07-15

    A simple method to generate cell microarrays with high-percentage well occupancy and well-defined cell confinement is presented. This method uses a synergistic combination of vacuum degassing and coverslip sweeping. The vacuum degassing step dislodges air bubbles from the microwells, which in turn enables the cells to enter the microwells, while the physical sweeping step using a glass coverslip removes the excess cells outside the microwells. This low-cost preparation method provides a simple solution to generating cell microarrays that can be performed in basic research laboratories and point-of-care settings for routine cell-based screening assays. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. LCR circuit: new simple methods for measuring the equivalent series resistance of a capacitor and inductance of a coil

    NASA Astrophysics Data System (ADS)

    Ivković, Saša S.; Marković, Marija Z.; Ivković, Dragica Ž.; Cvetanović, Nikola

    2017-09-01

    Equivalent series resistance (ESR) represents the measurement of total energy loss in a capacitor. In this paper a simple method for measuring the ESR of ceramic capacitors based on the analysis of the oscillations of an LCR circuit is proposed. It is shown that at frequencies under 3300 Hz, the ESR is directly proportional to the period of oscillations. Based on the determined dependence of the ESR on the period, a method is devised and tested for measuring coil inductance. All measurements were performed using the standard equipment found in student laboratories, which makes both methods very suitable for implementation at high school and university levels.

  17. Method and apparatus for recovering unstable cores

    DOEpatents

    McGuire, Patrick L.; Barraclough, Bruce L.

    1983-01-01

    A method and apparatus suitable for stabilizing hydrocarbon cores are given. Such stabilized cores have not previously been obtainable for laboratory study, and such study is believed to be required before the hydrate reserves can become a utilizable resource. The apparatus can be built using commercially available parts and is very simple and safe to operate.

  18. A Laboratory Experiment to Measure the Built-In Potential of a P-N Junction by a Photosaturation Method

    ERIC Educational Resources Information Center

    Ikram, I. Mohamed; Rabinal, M. K.; Mulimani, B. G.

    2009-01-01

    Here, we propose a simple method for measuring the built-in potential and its temperature dependence of a photodiode by a photosaturation technique. The experimental design facilitates both current-voltage and null voltage measurements as a function of white light intensity. This method gives the built-in potential directly; as a result its…

  19. Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria.

    PubMed

    Lucchi, Naomi W; Demas, Allison; Narayanan, Jothikumar; Sumari, Deborah; Kabanywanyi, Abdunoor; Kachur, S Patrick; Barnwell, John W; Udhayakumar, Venkatachalam

    2010-10-29

    Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.

  20. An easy, rapid and inexpensive method to monitor tributyltin (TBT) toxicity in the laboratory.

    PubMed

    Cruz, Andreia; Moreira, Rafael; Mendo, Sónia

    2014-05-01

    Tributyltin (TBT) contamination remains a major problem worldwide. Many laboratories are committed to the development of remediation methodologies that could help reduce the negative impact of this compound in the environment. Furthermore, it is important to have at hand simple methodologies for evaluating TBT toxicity in the laboratory, besides the use of complex and costly analytical instrumentation. With that purpose, a method was adapted that is based on the inhibition of growth of an indicator strain, Micrococcus luteus ATCC 9341, under TBT. Different types of matrices, of TBT concentrations and sample treatments were tested. The results herein reported show that the bioassay method can be applied for both aqueous and soil samples and also for a high range of TBT concentrations (at least up to 500 μmol/L). Besides being cheap and easy to perform, it can be performed in any laboratory. Additionally, one possible application of the method to monitor TBT degradation is presented as an example.

  1. Manual of analytical methods for the Environmental Health Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, C. E.

    1975-06-01

    This manual was compiled from techniques used In the Environmental Health Laboratory of Sandia Laboratories at Albuquerque. New Mexico, and is a revision of an earlier publication (SC-M-07-3044) edited by Lial W. Brewer. The procedures arc similar to those used in other laboratories devoted to Environmental Health practices. Some of the methods are standard and others are modified to suit our needs; others were developed at Sandia. The author has attempted to present all methods in a simple and concise manner, but in sufficient detail to make them readily usable. It is not inferred that the methods are universal formore » any type of sample, but they have been found very reliable for the types of samples mentioned. The author will welcome inquiry for clarification of any part of this manual. It is the desire of the author that this manual will be of use and service to others. New and revised procedures will be issued as supplements to this document.« less

  2. Laboratory procedure for estimating residue dynamics of xenobiotic contaminants in a freshwater food chain

    USGS Publications Warehouse

    Johnson, B. Thomas

    1980-01-01

    A laboratory method of measuring the accumulation, transfer, elimination, and degradation of xenobiotic contaminants is described for organisms in a freshwater food chain (microorganisms, filter-feeder, and fish). A flow-through diluter-system, 14C-labeled contaminants, gas and thin-layer chromatography, autoradiography, and liquid scintillation spectrometry are used in making residue determinations. Accumulation factors and various index values are developed for measuring and estimating potential accumulation of xenobiotic contaminants by aquatic organisms. The laboratory procedure is economical, simple, reproducible, and ecologically relevant.

  3. A new method of measuring gravitational acceleration in an undergraduate laboratory program

    NASA Astrophysics Data System (ADS)

    Wang, Qiaochu; Wang, Chang; Xiao, Yunhuan; Schulte, Jurgen; Shi, Qingfan

    2018-01-01

    This paper presents a high accuracy method to measure gravitational acceleration in an undergraduate laboratory program. The experiment is based on water in a cylindrical vessel rotating about its vertical axis at a constant speed. The water surface forms a paraboloid whose focal length is related to rotational period and gravitational acceleration. This experimental setup avoids classical source errors in determining the local value of gravitational acceleration, so prevalent in the common simple pendulum and inclined plane experiments. The presented method combines multiple physics concepts such as kinematics, classical mechanics and geometric optics, offering the opportunity for lateral as well as project-based learning.

  4. Effects of the Physical Laboratory versus the Virtual Laboratory in Teaching Simple Electric Circuits on Conceptual Achievement and Attitudes Towards the Subject

    ERIC Educational Resources Information Center

    Tekbiyik, Ahmet; Ercan, Orhan

    2015-01-01

    Current study examined the effects of virtual and physical laboratory practices on students' conceptual achievement in the subject of electricity and their attitudes towards simple electric circuits. Two groups (virtual and physical) selected through simple random sampling was taught with web-aided material called "Electricity in Our…

  5. An approach to quality and performance control in a computer-assisted clinical chemistry laboratory.

    PubMed Central

    Undrill, P E; Frazer, S C

    1979-01-01

    A locally developed, computer-based clinical chemistry laboratory system has been in operation since 1970. This utilises a Digital Equipment Co Ltd PDP 12 and an interconnected PDP 8/F computer. Details are presented of the performance and quality control techniques incorporated into the system. Laboratory performance is assessed through analysis of results from fixed-level control sera as well as from cumulative sum methods. At a simple level the presentation may be considered purely indicative, while at a more sophisticated level statistical concepts have been introduced to aid the laboratory controller in decision-making processes. PMID:438340

  6. A Laboratory Experiment of the Purification of Catalase.

    ERIC Educational Resources Information Center

    Busquets, Montserrat; Franco, Rafael

    1986-01-01

    Describes a simple method for purifying catalase for the study of proteins. Procedures are systematically and diagramatically presented. Also identifies polyacrylamide gel electrophoresis, kinetic studies, and apparent molecular weight determination as possible techniques to be used in studying proteins. (ML)

  7. Calculating the Degradation Rate of Individual Proteins Using Xenopus Extract Systems.

    PubMed

    McDowell, Gary S; Philpott, Anna

    2018-05-16

    The Xenopus extract system has been used extensively as a simple, quick, and robust method for assessing the stability of proteins against proteasomal degradation. In this protocol, methods are provided for assessing the half-life of in vitro translated radiolabeled proteins using Xenopus egg or embryo extracts. © 2019 Cold Spring Harbor Laboratory Press.

  8. Nondestructive assessment of timber bridges using a vibration-based method

    Treesearch

    Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw

    2005-01-01

    This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...

  9. CO[subscript 2] Rebreathing: An Undergraduate Laboratory to Study the Chemical Control of Breathing

    ERIC Educational Resources Information Center

    Domnik, N. J.; Turcotte, S. E.; Yuen, N. Y.; Iscoe, S.; Fisher, J. T.

    2013-01-01

    The Read CO[subscript]2 rebreathing method (Read DJ. "A clinical method for assessing the ventilatory response to carbon dioxide." "Australas Ann Med" 16: 20-32, 1967) provides a simple and reproducible approach for studying the chemical control of breathing. It has been widely used since the modifications made by Duffin and…

  10. Safe and consistent method of spot-welding platinum thermocouple wires and foils for high temperature measurements.

    PubMed

    Orr, G; Roth, M

    2012-08-01

    A low-voltage (mV) electronically triggered spot welding system for fabricating fine thermocouples and thin sheets used in high-temperature characterization of materials' properties is suggested. The system is based on the capacitance discharge method with a timed trigger for obtaining reliable and consistent welds. In contrast to existing techniques based on employing high voltage DC supplies for charging the capacitor or supplies with positive and negative rails, this method uses a simple, standard dual power supply available at most of the physical laboratories or can be acquired at a low cost. In addition, an efficient and simple method of fabricating non-sticking electrodes that do not contaminate the weld area is suggested and implemented.

  11. Multi-Laboratory Validation of Estrone (E1) ELISA Methods

    EPA Science Inventory

    This project is a round-robin evaluation of commercially available Enzyme-Linked Immunosorbent Assay (ELISA) technology to quantitatively or qualitatively measure the hormone estrone (E1) in combined animal feeding operation (CAFO) receiving streams. ELISA is meant to be a simpl...

  12. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  13. cp-R, an interface the R programming language for clinical laboratory method comparisons.

    PubMed

    Holmes, Daniel T

    2015-02-01

    Clinical scientists frequently need to compare two different bioanalytical methods as part of assay validation/monitoring. As a matter necessity, regression methods for quantitative comparison in clinical chemistry, hematology and other clinical laboratory disciplines must allow for error in both the x and y variables. Traditionally the methods popularized by 1) Deming and 2) Passing and Bablok have been recommended. While commercial tools exist, no simple open source tool is available. The purpose of this work was to develop and entirely open-source GUI-driven program for bioanalytical method comparisons capable of performing these regression methods and able to produce highly customized graphical output. The GUI is written in python and PyQt4 with R scripts performing regression and graphical functions. The program can be run from source code or as a pre-compiled binary executable. The software performs three forms of regression and offers weighting where applicable. Confidence bands of the regression are calculated using bootstrapping for Deming and Passing Bablok methods. Users can customize regression plots according to the tools available in R and can produced output in any of: jpg, png, tiff, bmp at any desired resolution or ps and pdf vector formats. Bland Altman plots and some regression diagnostic plots are also generated. Correctness of regression parameter estimates was confirmed against existing R packages. The program allows for rapid and highly customizable graphical output capable of conforming to the publication requirements of any clinical chemistry journal. Quick method comparisons can also be performed and cut and paste into spreadsheet or word processing applications. We present a simple and intuitive open source tool for quantitative method comparison in a clinical laboratory environment. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. A Simple Laboratory Exercise Illustrating Active Transport in Yeast Cells.

    ERIC Educational Resources Information Center

    Stambuk, Boris U.

    2000-01-01

    Describes a simple laboratory activity illustrating the chemiosmotic principles of active transport in yeast cells. Demonstrates the energy coupling mechanism of active a-glucoside uptake by Saccaromyces cerevisiae cells with a colorimetric transport assay using very simple equipment. (Contains 22 references.) (Author/YDS)

  15. Nondestructive assessment of single-span timber bridges using a vibration- based method

    Treesearch

    Xiping Wang; James P. Wacker; Angus M. Morison; John W. Forsman; John R. Erickson; Robert J. Ross

    2005-01-01

    This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...

  16. Kinetics and Mechanism of Iodide Oxidation by Iron(III): A Clock Reaction Approach

    ERIC Educational Resources Information Center

    Bauer, Jurica; Tomisic, Vladislav; Vrkljan, Petar B. A.

    2008-01-01

    A simple method for studying the kinetics of a chemical reaction is described and the significance of reaction orders in deducing reaction mechanisms is demonstrated. In this student laboratory experiment, oxidation of iodide by iron(III) ions in an acidic medium is transformed into a clock reaction. By means of the initial rates method, it is…

  17. Which Method Is Most Precise; Which Is Most Accurate? An Undergraduate Experiment

    ERIC Educational Resources Information Center

    Jordan, A. D.

    2007-01-01

    A simple experiment, the determination of the density of a liquid by several methods, is presented. Since the concept of density is a familiar one, the experiment is suitable for the introductory laboratory period of a first- or second-year course in physical or analytical chemistry. The main objective of the experiment is to familiarize students…

  18. The Nitrogen Excretory Metabolism of Lumbricus Terrestris

    ERIC Educational Resources Information Center

    Teal, A. R.

    1977-01-01

    The use of the earthworm as a laboratory animal for studying the effect of starvation on nitrogen metabolism is discussed. Simple techniques and methods are presented allowing in vivo physiological responses to be compared with changes in the enzyme potential of gut tissue. (Author/MA)

  19. A SIMPLE COLORIMETRIC METHOD TO DETECT BIOLOGICAL EVIDENCE OF HUMAN EXPOSURE TO MICROCYSTINS

    EPA Science Inventory

    Toxic cyanobacteria are contaminants of surface waters worldwide. Microcystins are some of the most commonly detected toxins. Biological evidence of human exposure may be difficult to obtain due to limitations associated with cost, laboratory capacity, analytic support, and exp...

  20. High density lipoproteins: Measurement techniques and potential biomarkers of cardiovascular risk

    PubMed Central

    Hafiane, Anouar; Genest, Jacques

    2015-01-01

    Plasma high density lipoprotein cholesterol (HDL) comprises a heterogeneous family of lipoprotein species, differing in surface charge, size and lipid and protein compositions. While HDL cholesterol (C) mass is a strong, graded and coherent biomarker of cardiovascular risk, genetic and clinical trial data suggest that the simple measurement of HDL-C may not be causal in preventing atherosclerosis nor reflect HDL functionality. Indeed, the measurement of HDL-C may be a biomarker of cardiovascular health. To assess the issue of HDL function as a potential therapeutic target, robust and simple analytical methods are required. The complex pleiotropic effects of HDL make the development of a single measurement challenging. Development of laboratory assays that accurately HDL function must be developed validated and brought to high-throughput for clinical purposes. This review discusses the limitations of current laboratory technologies for methods that separate and quantify HDL and potential application to predict CVD, with an emphasis on emergent approaches as potential biomarkers in clinical practice. PMID:26674734

  1. Assessment of Proficiency and Competency in Laboratory Animal Biomethodologies

    PubMed Central

    Clifford, Paula; Melfi, Natasha; Bogdanske, John; Johnson, Elizabeth J; Kehler, James; Baran, Szczepan W

    2013-01-01

    Personnel working with laboratory animals are required by laws and guidelines to be trained and qualified to perform biomethodologic procedures. The assessment of competency and proficiency is a vital component of a laboratory animal training program, because this process confirms that the trainees have met the learning objectives for a particular procedure. The approach toward qualification assessment differs between organizations because laws and guidelines do not outline how the assessment should be performed or which methods and tools should be used. Assessment of clinical and surgical medicine has received considerable attention over the last few decades and has progressed from simple subjective methods to well-defined and objective methods of assessing competency. Although biomethodology competency and proficiency assessment is discussed in the literature, a standard and objective assessment method has not yet been developed. The development and implementation of an objective and standardized biomethodologic assessment program can serve as a tool to improve standards, ensure consistent training, and decrease research variables yet ensure animal welfare. Here we review the definition and goals of training and assessment, review assessment methods, and propose a method to develop a standard and objective assessment program for the laboratory animal science field, particularly training departments and IACUC. PMID:24351758

  2. Baking sunflower hulls within an aluminum envelope in a common laboratory oven yields charcoal.

    PubMed

    Arnal, Pablo Maximiliano

    2015-01-01

    Charcoals have been widely used by scientist to research the removal of contaminants from water and air. One key feature of charcoal is that it keeps macropores from the parent material - though anisotropically contracted - and can even develop meso- and micropores. However, the controlled thermochemical conversion of biomass into charcoal at laboratory scale normally requires special setups which involve either vacuum or inert gas. Those setups may not be affordable in research groups or educational institutions where the research of charcoals would be highly welcome. In this work, I propose a simple and effective method to steer the thermochemical process that converts sunflower hulls (SFH) into charcoal with basic laboratory resources. The carbonization method: •Place SFH in an airtight aluminum envelope.•Thermally treat SFH within the envelope in a common laboratory oven.•Open the envelope to obtain the carbonized sunflower hulls.

  3. Random amplified polymorphic DNA PCR in the teaching of molecular epidemiology.

    PubMed

    Reinoso, Elina B; Bettera, Susana G

    2016-07-08

    In this article, we describe a basic practical laboratory designed for fifth-year undergraduate students of Microbiology as part of the Epidemiology course. This practice provides the students with the tools for molecular epidemiological analysis of pathogenic microorganisms using a rapid and simple PCR technique. The aim of this work was to assay RAPD-PCR technique in order to infer possible epidemiological relationships. The activity gives students an appreciation of the value of applying a simple molecular biological method as RAPD-PCR to a discipline-specific question. It comprises a three-session laboratory module to genetically assay DNAs from strains isolated from a food outbreak. © 2016 by The International Union of Biochemistry and Molecular Biology, 44(4):391-396, 2016. © 2016 The International Union of Biochemistry and Molecular Biology.

  4. Measuring g Using a Magnetic Pendulum and Telephone Pickup

    NASA Astrophysics Data System (ADS)

    Sinacore, J.; Takai, H.

    2010-10-01

    The simple pendulum has long been used to measure g, the acceleration due to gravity, with a precision of a few percent. Achieving agreement with the accepted value of less than 1% is feasible in the high school laboratory, though it requires some care. The precision of the measurement is bound by how accurately the period and the pendulum length are determined. To improve on the period measurement, we have developed a simple and inexpensive method using a magnet and telephone pickup.2

  5. On-Site Molecular Detection of Soil-Borne Phytopathogens Using a Portable Real-Time PCR System

    PubMed Central

    DeShields, Joseph B.; Bomberger, Rachel A.; Woodhall, James W.; Wheeler, David L.; Moroz, Natalia; Johnson, Dennis A.; Tanaka, Kiwamu

    2018-01-01

    On-site diagnosis of plant diseases can be a useful tool for growers for timely decisions enabling the earlier implementation of disease management strategies that reduce the impact of the disease. Presently in many diagnostic laboratories, the polymerase chain reaction (PCR), particularly real-time PCR, is considered the most sensitive and accurate method for plant pathogen detection. However, laboratory-based PCRs typically require expensive laboratory equipment and skilled personnel. In this study, soil-borne pathogens of potato are used to demonstrate the potential for on-site molecular detection. This was achieved using a rapid and simple protocol comprising of magnetic bead-based nucleic acid extraction, portable real-time PCR (fluorogenic probe-based assay). The portable real-time PCR approach compared favorably with a laboratory-based system, detecting as few as 100 copies of DNA from Spongospora subterranea. The portable real-time PCR method developed here can serve as an alternative to laboratory-based approaches and a useful on-site tool for pathogen diagnosis. PMID:29553557

  6. Recommendation for the review of biological reference intervals in medical laboratories.

    PubMed

    Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel

    2016-12-01

    This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.

  7. Preparation of bone samples in the Gliwice Radiocarbon Laboratory for AMS radiocarbon dating.

    PubMed

    Piotrowska, N; Goslar, T

    2002-12-01

    In the Gliwice Radiocarbon Laboratory, a system for preparation of samples for AMS dating has been built. At first it was used to produce graphite targets from plant macrofossils and sediments. In this study we extended its capabilities with the preparation of bones. We dealt with 3 methods; the first was the classical Longin method of collagen extraction, the second one included additional treatment of powdered bone in alkali solution, while in the third one carboxyl carbon was separated from amino acids obtained after hydrolysis of protein. The suitability of the methods was tested on 2 bone samples. Most of our samples gave ages > 40 kyr BP, suggesting good performance of the adapted methods, except for one sample prepared with simple Longin method. For routine preparation of bones we chose the Longin method with additional alkali treatment.

  8. Different spectrophotometric methods applied for the analysis of simeprevir in the presence of its oxidative degradation product: Acomparative study

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; El-Abasawi, Nasr M.; El-Olemy, Ahmed; Serag, Ahmed

    2018-02-01

    Five simple spectrophotometric methods were developed for the determination of simeprevir in the presence of its oxidative degradation product namely, ratio difference, mean centering, derivative ratio using the Savitsky-Golay filters, second derivative and continuous wavelet transform. These methods are linear in the range of 2.5-40 μg/mL and validated according to the ICH guidelines. The obtained results of accuracy, repeatability and precision were found to be within the acceptable limits. The specificity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. Furthermore, these methods were statistically comparable to RP-HPLC method and good results were obtained. So, they can be used for the routine analysis of simeprevir in quality-control laboratories.

  9. Geochemical field method for determination of nickel in plants

    USGS Publications Warehouse

    Reichen, L.E.

    1951-01-01

    The use of biogeochemical data in prospecting for nickel emphasizes the need for a simple, moderately accurate field method for the determination of nickel in plants. In order to follow leads provided by plants of unusual nickel content without loss of time, the plants should be analyzed and the results given to the field geologist promptly. The method reported in this paper was developed to meet this need. Speed is acquired by elimination of the customary drying and controlled ashing; the fresh vegetation is ashed in an open dish over a gasoline stove. The ash is put into solution with hydrochloric acid and the solution buffered. A chromograph is used to make a confined spot with an aliquot of the ash solution on dimethylglyoxime reagent paper. As little as 0.025% nickel in plant ash can be determined. With a simple modification, 0.003% can be detected. Data are given comparing the results obtained by an accepted laboratory procedure. Results by the field method are within 30% of the laboratory values. The field method for nickel in plants meets the requirements of biogeochemical prospecting with respect to accuracy, simplicity, speed, and ease of performance in the field. With experience, an analyst can make 30 determinations in an 8-hour work day in the field.

  10. [The actual possibilities of robotic microscopy in analysis automation and laboratory telemedicine].

    PubMed

    Medovyĭ, V S; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Balugian, R Sh

    2012-10-01

    The article discusses the possibilities of automation microscopy complexes manufactured by Cellavision and MEKOS to perform the medical analyses of blood films and other biomaterials. The joint work of the complex and physician in the regimen of automatic load stages, screening, sampling and sorting on types with simple morphology, visual sorting of sub-sample with complex morphology provides significant increase of method sensitivity, load decrease and enhancement of physician work conditions. The information technologies, the virtual slides and laboratory telemedicine included permit to develop the representative samples of rare types and pathologies to promote automation methods and medical research targets.

  11. Watertight cataract incision closure using fibrin tissue adhesive.

    PubMed

    Hovanesian, John A; Karageozian, Vicken H

    2007-08-01

    To determine whether a simple method for applying fibrin tissue adhesive to a clear corneal cataract incision can create a watertight seal. Laboratory investigation. Clear corneal cataract incisions were simulated in 8 eye-bank eyes. In 4 eyes, fibrin adhesive was applied to the incision in a simple manner; the other 4 eyes were controls with no adhesive. Each eye was tested under low pressure conditions to detect fluid ingress of India Ink on the eye's surface. The eyes were tested again with external compression to distort the incision to detect fluid egress. In the eyes with fibrin adhesive, there was no egress of fluid with incision distortion and no ingress of India Ink. In the 4 eyes without adhesive, there was ingress and egress of fluid. A simple method of applying fibrin adhesive to cataract incisions created a watertight seal.

  12. Determination of the Effect of Various Modes of Cooking on the Vitamin C Content of a Common Food, Green Pepper: An Introductory Biochemistry Experiment.

    ERIC Educational Resources Information Center

    Johnson, Eric R.

    1988-01-01

    Describes a laboratory experiment that measures the amount of ascorbic acid destroyed by food preparation methods (boiling and steaming). Points out that aqueous extracts of cooked green pepper samples can be analyzed for ascorbic acid by a relatively simple redox titration. Lists experimental procedure for four methods of preparation. (MVL)

  13. Electrochemical Assay of Gold-Plating Solutions

    NASA Technical Reports Server (NTRS)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  14. Keeping It Simple: Can We Estimate Malting Quality Potential Using an Isothermal Mashing Protocol and Common Laboratory Instrumentation?

    USDA-ARS?s Scientific Manuscript database

    Current methods for generating malting quality metrics have been developed largely to support commercial malting and brewing operations, providing accurate, reproducible analytical data to guide malting and brewing production. Infrastructure to support these analytical operations often involves sub...

  15. A Simple Method for Measuring Ground-Level Ozone in the Atmosphere

    ERIC Educational Resources Information Center

    Seeley, John V.; Seeley, Stacy K.; Bull, Arthur W.; Fehir, Richard J., Jr.; Cornwall, Susan; Knudsen, Gabriel A.

    2005-01-01

    An iodometric assay that allows the ground-level ozone concentration to be determined with an inexpensive sampling apparatus and a homemade photometer is described. This laboratory experiment applies a variety of different fundamental concepts including oxidation-reduction chemistry, the ideal gas law, and spectroscopic analysis and also provides…

  16. Readily Made Solvated Electrons

    ERIC Educational Resources Information Center

    Ibanez, Jorge G.; Guerra-Millan, Francisco J.; Hugerat, Muhamad; Vazquez-Olavarrieta, Jorge L.; Basheer, Ahmad; Abu-Much, Riam

    2011-01-01

    The existence of solvated electrons has been known for a long time. Key methods for their production (i.e., photoionization of reducing ions, water radiolysis, and the reaction between H[middle dot] and OH[superscript -]) are unsuitable for most school laboratories. We describe a simple experiment to produce liquid ammonia and solvated electrons…

  17. Experimental Analysis of Cell Function Using Cytoplasmic Streaming

    ERIC Educational Resources Information Center

    Janssens, Peter; Waldhuber, Megan

    2012-01-01

    This laboratory exercise investigates the phenomenon of cytoplasmic streaming in the fresh water alga "Nitella". Students use the fungal toxin cytochalasin D, an inhibitor of actin polymerization, to investigate the mechanism of streaming. Students use simple statistical methods to analyze their data. Typical student data are provided. (Contains 3…

  18. Thermocouples for forest fire research

    Treesearch

    Erwin H. Breuer

    1965-01-01

    Thermocouples have proved valuable in research conducted by the Fire Physics Project at the Northern Forest Fire Laboratory because they can measure several important fire variables besides flame and convection column temperatures. These include rate of spread and flame residence time. Describes a simple, rapid method of fabrication and reports useful and diverse...

  19. Investigating the Boron Requirement of Plants.

    ERIC Educational Resources Information Center

    Bohnsack, Charles W.

    1991-01-01

    This article describes a simple and rapid method for using summer squash to investigate born deficiency in plants. Author asserts that students are likely to feel challenged by laboratory exercises and projects that focus on the role boron plays in plant growth because it is an unresolved problem in biology. (PR)

  20. Use of a Simple, Colorimetric Assay to Demonstrate Conditions for Induction of Nitrate Reductase in Plants.

    ERIC Educational Resources Information Center

    Harley, Suzanne M.

    1993-01-01

    Nitrate assimilation by plants provides an excellent system for demonstrating control of gene expression in a eukaryotic organism. Describes an assay method that allows students to complete experiments designed around the measurement of nitrate reductase within a three-hour laboratory experiment. (PR)

  1. Optimized theory for simple and molecular fluids.

    PubMed

    Marucho, M; Montgomery Pettitt, B

    2007-03-28

    An optimized closure approximation for both simple and molecular fluids is presented. A smooth interpolation between Perkus-Yevick and hypernetted chain closures is optimized by minimizing the free energy self-consistently with respect to the interpolation parameter(s). The molecular version is derived from a refinement of the method for simple fluids. In doing so, a method is proposed which appropriately couples an optimized closure with the variant of the diagrammatically proper integral equation recently introduced by this laboratory [K. M. Dyer et al., J. Chem. Phys. 123, 204512 (2005)]. The simplicity of the expressions involved in this proposed theory has allowed the authors to obtain an analytic expression for the approximate excess chemical potential. This is shown to be an efficient tool to estimate, from first principles, the numerical value of the interpolation parameters defining the aforementioned closure. As a preliminary test, representative models for simple fluids and homonuclear diatomic Lennard-Jones fluids were analyzed, obtaining site-site correlation functions in excellent agreement with simulation data.

  2. Spectrophotometric determination of meclizine hydrochloride and pyridoxine hydrochloride in laboratory prepared mixtures and in their pharmaceutical preparation

    NASA Astrophysics Data System (ADS)

    Ibrahim, Maha M.; Elzanfaly, Eman S.; El-Zeiny, Mohamed B.; Ramadan, Nesreen K.; Kelani, Khadiga M.

    2017-05-01

    In this paper, three rapid, simple, accurate and precise spectrophotometric methods were developed for the determination of meclizine hydrochloride in the presence of pyridoxine hydrochloride without previous separation. The methods under study are dual wavelength (DWL), ratio difference (RD) and continuous wavelet transform (CWT). On the other hand, pyridoxine hydrochloride (PYH) was determined directly at 291 nm. The methods obey Beer's law in the range of (5-50 μg/mL) for both compounds. All the methods were validated according to the ICH guidelines where the accuracy was found to be 98.29, 99.59, 100.42 and 100.62% for DWL, RD, CWT and PYH; respectively. Moreover the precision of the methods were calculated in terms of %RSD and it was found to be 0.545, 0.372, 1.287 and 0.759 for DWL, RD,CWT and PYH; respectively. The selectivity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. So, they can be used for the routine analysis of pyridoxine hydrochloride and meclizine hydrochloride in quality-control laboratories.

  3. Resolution of plasma sample mix-ups through comparison of patient antibody patterns to E. coli.

    PubMed

    Vetter, Beatrice N; Orlowski, Vanessa; Schüpbach, Jörg; Böni, Jürg; Rühe, Bettina; Huder, Jon B

    2015-12-01

    Accidental sample mix-ups and the need for their swift resolution is a challenge faced by every analytical laboratory. To this end, we developed a simple immunoblot-based method, making use of a patient's characteristic plasma antibody profile to Escherichia coli (E. coli) proteins. Nitrocellulose strips of size-separated proteins from E. coli whole-cell lysates were incubated with patient plasma and visualised with an enzyme-coupled secondary antibody and substrate. Plasma samples of 20 random patients as well as five longitudinal samples of three patients were analysed for antibody band patterns, to evaluate uniqueness and consistency over time, respectively. For sample mix-ups, antibody band patterns of questionable samples were compared with samples of known identity. Comparison of anti-E. coli antibody patterns of 20 random patients showed a unique antibody profile for each patient. Antibody profiles remained consistent over time, as shown for three patients over several years. Three example cases demonstrate the use of this methodology in mis-labelling or -pipetting incidences. Our simple method for resolving plasma sample mix-ups between non-related individuals can be performed with basic laboratory equipment and thus can easily be adopted by analytical laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  5. The Synthetic Experiment: E. B. Titchener's Cornell Psychological Laboratory and the Test of Introspective Analysis.

    PubMed

    Evans, Rand B

    2017-01-01

    Beginning in 1 9a0, a major thread of research was added to E. B. Titchener's Cornell laboratory: the synthetic experiment. Titchener and his graduate students used introspective analysis to reduce a perception, a complex experience, into its simple sensory constituents. To test the validity of that analysis, stimulus patterns were selected to reprodiuce the patterns of sensations found in the introspective analyses. If the original perception can be reconstructed in this way, then the analysis was considered validated. This article reviews development of the synthetic method in E. B. Titchener's laboratory at Cornell University and examines its impact on psychological research.

  6. Laser Speckle Photography: Some Simple Experiments for the Undergraduate Laboratory.

    ERIC Educational Resources Information Center

    Bates, B.; And Others

    1986-01-01

    Describes simple speckle photography experiments which are easy to set up and require only low cost standard laboratory equipment. Included are procedures for taking single, double, and multiple exposures. (JN)

  7. A survey on the utilization of disposable quadrant articulators.

    PubMed

    Thornton, Linda J

    2002-01-01

    This study evaluated utilization of the six most popular disposable quadrant articulators presently used in crown fabrication. Most general practitioners and crown and bridge laboratory technicians reported that they frequently or always used disposable quadrant articulators for single units and simple three-unit fixed partial dentures. All evaluated articulators demonstrated an inability to maintain and repeat the centric stop position. The disposable quadrant articulator, used in combination with dual-arch impressions, is a viable method for fabricating single and short-span restorations. While a nonrepeatable centric stop was present in all six articulators evaluated, the method was considered a time-efficient and cost-saving alternative to traditional all-metal simple-hinge articulators.

  8. Fluorescence Spectrometric Determination of Drugs Containing α-Methylene Sulfone/Sulfonamide Functional Groups Using N-Methylnicotinamide Chloride as a Fluorogenic Agent.

    PubMed

    Elokely, Khaled M; Eldawy, Mohamed A; Elkersh, Mohamed A; El-Moselhy, Tarek F

    2011-01-01

    A simple spectrofluorometric method has been developed, adapted, and validated for the quantitative estimation of drugs containing α-methylene sulfone/sulfonamide functional groups using N(1)-methylnicotinamide chloride (NMNCl) as fluorogenic agent. The proposed method has been applied successfully to the determination of methyl sulfonyl methane (MSM) (1), tinidazole (2), rofecoxib (3), and nimesulide (4) in pure forms, laboratory-prepared mixtures, pharmaceutical dosage forms, spiked human plasma samples, and in volunteer's blood. The method showed linearity over concentration ranging from 1 to 150 μg/mL, 10 to 1000 ng/mL, 1 to 1800 ng/mL, and 30 to 2100 ng/mL for standard solutions of 1, 2, 3, and 4, respectively, and over concentration ranging from 5 to 150 μg/mL, 10 to 1000 ng/mL, 10 to 1700 ng/mL, and 30 to 2350 ng/mL in spiked human plasma samples of 1, 2, 3, and 4, respectively. The method showed good accuracy, specificity, and precision in both laboratory-prepared mixtures and in spiked human plasma samples. The proposed method is simple, does not need sophisticated instruments, and is suitable for quality control application, bioavailability, and bioequivalency studies. Besides, its detection limits are comparable to other sophisticated chromatographic methods.

  9. An Operationally Simple Sonogashira Reaction for an Undergraduate Organic Chemistry Laboratory Class

    ERIC Educational Resources Information Center

    Cranwell, Philippa B.; Peterson, Alexander M.; Littlefield, Benjamin T. R.; Russell, Andrew T.

    2015-01-01

    An operationally simple, reliable, and cheap Sonogashira reaction suitable for an undergraduate laboratory class that can be completed within a day-long (8 h) laboratory session has been developed. Cross-coupling is carried out between 2-methyl-3-butyn-2-ol and various aryl iodides using catalytic amounts of bis(triphenylphosphine)palladium(II)…

  10. Cost evaluation of clinical laboratory in Taiwan's National Health System by using activity-based costing.

    PubMed

    Su, Bin-Guang; Chen, Shao-Fen; Yeh, Shu-Hsing; Shih, Po-Wen; Lin, Ching-Chiang

    2016-11-01

    To cope with the government's policies to reduce medical costs, Taiwan's healthcare service providers are striving to survive by pursuing profit maximization through cost control. This article aimed to present the results of cost evaluation using activity-based costing performed in the laboratory in order to throw light on the differences between costs and the payment system of National Health Insurance (NHI). This study analyzed the data of costs and income of the clinical laboratory. Direct costs belong to their respective sections of the department. The department's shared costs, including public expenses and administrative assigned costs, were allocated to the department's respective sections. A simple regression equation was created to predict profit and loss, and evaluate the department's break-even point, fixed cost, and contribution margin ratio. In clinical chemistry and seroimmunology sections, the cost per test was lower than the NHI payment and their major laboratory tests had revenues with the profitability ratio of 8.7%, while the other sections had a higher cost per test than the NHI payment and their major tests were in deficit. The study found a simple linear regression model as follows: "Balance=-84,995+0.543×income (R2=0.544)". In order to avoid deficit, laboratories are suggested to increase test volumes, enhance laboratory test specialization, and become marginal scale. A hospital could integrate with regional medical institutions through alliances or OEM methods to increase volumes to reach marginal scale and reduce laboratory costs, enhancing the level and quality of laboratory medicine.

  11. Miniaturized Sample Preparation and Rapid Detection of Arsenite in Contaminated Soil Using a Smartphone.

    PubMed

    Siddiqui, Mohd Farhan; Kim, Soocheol; Jeon, Hyoil; Kim, Taeho; Joo, Chulmin; Park, Seungkyung

    2018-03-04

    Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III) in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample) and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.

  12. A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.

    PubMed

    Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste

    2018-02-01

    To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV% < 10%), whatever the considered method. The mechanical variables ([Formula: see text], [Formula: see text]) measured with the 2 methods and all the variables extrapolated from the F-v relationships were strongly correlated (r 2  > .80, P < .001). The practical differences between the methods for the extrapolated mechanical parameters were all <5%, indicating very probably no differences. The findings suggest that the simple computation method used here provides valid and reliable information on force and velocity produced during ballistic bench press, in line with that observed in laboratory conditions. This simple method is thus a practical tool, requiring only 3 simple parameters (upper-limb mass, barbell flight height, and push-off distance).

  13. Characterizing oxidative flow reactor SOA production and OH radical exposure from laboratory experiments of complex mixtures (engine exhaust) and simple precursors (monoterpenes)

    NASA Astrophysics Data System (ADS)

    Michael Link, M. L.; Friedman, B.; Ortega, J. V.; Son, J.; Kim, J.; Park, G.; Park, T.; Kim, K.; Lee, T.; Farmer, D.

    2016-12-01

    Recent commercialization of the Oxidative Flow Reactor (OFR, occasionally described in the literature as a "Potential Aerosol Mass") has created the opportunity for many researchers to explore the mechanisms behind OH-driven aerosol formation on a wide range of oxidative timescales (hours to weeks) in both laboratory and field measurements. These experiments have been conducted in both laboratory and field settings, including simple (i.e. single component) and complex (multi-component) precursors. Standard practices for performing OFR experiments, and interpreting data from the measurements, are still being developed. Measurement of gas and particle phase chemistry, from oxidation products generated in the OFR, through laboratory studies on single precursors and the measurement of SOA from vehicle emissions on short atmospheric timescales represent two very different experiments in which careful experimental design is essential for exploring reaction mechanisms and SOA yields. Two parameters essential in experimental design are (1) the role of seed aerosol in controlling gas-particle partitioning and SOA yields, and (2) the accurate determination of OH exposure during any one experiment. We investigated the role of seed aerosol surface area in controlling the observed SOA yields and gas/particle composition from the OH-initiated oxidation of four monoterpenes using an aerosol chemical ionization time-of-flight mass spectrometer and scanning mobility particle sizer. While the OH exposure during laboratory experiments is simple to constrain, complex mixtures such as diesel exhaust have high estimated OH reactivity values, and thus require careful consideration. We developed methods for constraining OH radical exposure in the OFR during vehicle exhaust oxidation experiments. We observe changes in O/C ratios and highly functionalized species over the temperature gradient employed in the aerosol-CIMS measurement. We relate this observed, speciated chemistry to the volatility of the aerosol, and compare observed SOA yields to other OFR and smog chamber SOA generation methods. Additionally, estimates of OH radical exposure in the OFR during different vehicle experiments of varying fuel type and speed were observed to vary as determined from a high-NOx and variable humidity calibration set.

  14. Validation of a simple, manual urinary iodine method for estimating the prevalence of iodine-deficiency disorders, and interlaboratory comparison with other methods.

    PubMed

    May, S L; May, W A; Bourdoux, P P; Pino, S; Sullivan, K M; Maberly, G F

    1997-05-01

    The measurement of urinary iodine in population-based surveys provides a biological indicator of the severity of iodine-deficiency disorders. We describe the steps performed to validate a simple, inexpensive, manual urinary iodine acid digestion method, and compare the results using this method with those of other urinary iodine methods. Initially, basic performance characteristics were evaluated: the average recovery of added iodine was 100.4 +/- 8.7% (mean +/- SD), within-assay precision (CV) over the assay range 0-0.95 mumol/L (0-12 micrograms/dL) was < 6%, between-assay precision over the same range was < 12%, and assay sensitivity was 0.05 mumol/L (0.6 microgram/dL). There were no apparent effects on the method by thiocyanate, a known interfering substance. In a comparison with five other methods performed in four different laboratories, samples were collected to test the method performance over a wide range of urinary iodine values (0.04-3.7 mumol/L, or 0.5-47 micrograms/dL). There was a high correlation between all methods and the interpretation of the results was consistent. We conclude that the simple, manual acid digestion method is suitable for urinary iodine analysis.

  15. A Simple and Low-Cost Ultramicroelectrode Fabrication and Characterization Method for Undergraduate Students

    ERIC Educational Resources Information Center

    Sur, Ujjal Kumar; Dhason, A.; Lakshminarayanan, V.

    2012-01-01

    A laboratory experiment is described in which students fabricate disk-shaped gold and platinum microelectrodes with diameters of 10-50 [mu]m by sealing sodalime glass with metal microwires. The electrodes are characterized by performing cyclic voltammetry in aqueous and acetonitrile solution. Commercial microelectrodes are expensive (cost depends…

  16. Seeding and Planting Southern Hardwoods

    Treesearch

    Franklin T. Bonner

    1965-01-01

    I would like to start by giving a complete prescription for planting any hardwood species by a cheap and simple method that will insure excellent survival and good growth. Unfortunately, this is impossible, for we at the Southern Hardwoods Laboratory are still several years away from such prescriptions with nearly all of our important hardwoods. With most species,...

  17. A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt

    Treesearch

    Carol A. Clausen; Vina W. Yang

    2011-01-01

    Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...

  18. Making and Using a Sensing Polymeric Material for Cu[superscript 2+

    ERIC Educational Resources Information Center

    Paddock, Jean R.; Maghasi, Anne T.; Heineman, William R.; Seliskar, Carl J.

    2005-01-01

    A simple chemical sensor-related experiment rooted in the synthesis of polymeric materials for use in either an advanced high-school or undergraduate college laboratory is presented. Students are introduced to and combine to the concepts of the chemical sensor, polymer chemistry, spectroscopy, metal chelates, and quantitative analytical methods.

  19. Investigation and Implementation of Commercially Available Optically Stimulated Luminescence Dosimeters for Use in Fixed Nuclear Accident Dosimeter Systems.

    PubMed

    Georgeson, David L; Christiansen, Byron H

    2018-06-01

    Idaho National Laboratory transitioned from an external dosimetry system reliant on thermoluminescent dosimeters to one that uses optically stimulated luminescence dosimeters in 2010. This change not only affected the dosimeters worn by personnel, but those found in the nuclear-accident dosimeters used across Idaho National Laboratory. The elimination of on-site use and processing of thermoluminescent dosimeters impacted Idaho National Laboratory's ability to process nuclear-accident dosimeters in a timely manner. This change in processes drove Idaho National Laboratory to develop an alternative method for fixed nuclear-accident dosimeter gamma-dose analyses. This new method was driven by the need to establish a simple, cost-effective, and rapid-turnaround alternative to the thermoluminescent-dosimeter-based fixed nuclear-accident dosimeter system. An adaptation of existing technologies proved to be the most efficient path to this end. The purpose of this article is to delineate the technical basis for replacing the thermoluminescent dosimeter contained within the Idaho National Laboratory fixed nuclear-accident dosimeter system with optically stimulated luminescence-based Landauer, Inc., nanoDot dosimeters.

  20. Determination of total monomeric anthocyanin pigment content of fruit juices, beverages, natural colorants, and wines by the pH differential method: collaborative study.

    PubMed

    Lee, Jungmin; Durst, Robert W; Wrolstad, Ronald E

    2005-01-01

    This collaborative study was conducted to determine the total monomeric anthocyanin concentration by the pH differential method, which is a rapid and simple spectrophotometric method based on the anthocyanin structural transformation that occurs with a change in pH (colored at pH 1.0 and colorless at pH 4.5). Eleven collaborators representing commercial laboratories, academic institutions, and government laboratories participated. Seven Youden pair materials representing fruit juices, beverages, natural colorants, and wines were tested. The repeatability relative standard deviation (RSDr) varied from 1.06 to 4.16%. The reproducibility relative standard deviation (RSDR) ranged from 2.69 to 10.12%. The HorRat values were < or = 1.33 for all materials. The Study Director recommends that the method be adopted Official First Action.

  1. Measurement of the sound absorption coefficient for an advanced undergraduate physics laboratory

    NASA Astrophysics Data System (ADS)

    Macho-Stadler, E.; Elejalde-García, M. J.

    2017-09-01

    We present a simple experiment that allows advanced undergraduates to learn the basics of the acoustic properties of materials. The impedance tube-standing wave method is applied to study the normal absorption coefficient of acoustics insulators. The setup includes a tube, a speaker, a microphone, a digital function generator and an oscilloscope, material available in an undergraduate laboratory. Results of the change of the absorption coefficient with the frequency, the sample thickness and the sample density are analysed and compared with those obtained with a commercial system.

  2. How to Recognize Success and Failure: Practical Assessment of an Evolving, First-Semester Laboratory Program Using Simple, Outcome-Based Tools

    ERIC Educational Resources Information Center

    Gron, Liz U.; Bradley, Shelly B.; McKenzie, Jennifer R.; Shinn, Sara E.; Teague, M. Warfield

    2013-01-01

    This paper presents the use of simple, outcome-based assessment tools to design and evaluate the first semester of a new introductory laboratory program created to teach green analytical chemistry using environmental samples. This general chemistry laboratory program, like many introductory courses, has a wide array of stakeholders within and…

  3. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  4. Rapid fabrication of microfluidic chips based on the simplest LED lithography

    NASA Astrophysics Data System (ADS)

    Li, Yue; Wu, Ping; Luo, Zhaofeng; Ren, Yuxuan; Liao, Meixiang; Feng, Lili; Li, Yuting; He, Liqun

    2015-05-01

    Microfluidic chips are generally fabricated by a soft lithography method employing commercial lithography equipment. These heavy machines require a critical room environment and high lamp power, and the cost remains too high for most normal laboratories. Here we present a novel microfluidics fabrication method utilizing a portable ultraviolet (UV) LED as an alternative UV source for photolithography. With this approach, we can repeat several common microchannels as do these conventional commercial exposure machines, and both the verticality of the channel sidewall and lithography resolution are proved to be acceptable. Further microfluidics applications such as mixing, blood typing and microdroplet generation are implemented to validate the practicability of the chips. This simple but innovative method decreases the cost and requirement of chip fabrication dramatically and may be more popular with ordinary laboratories.

  5. Stability indicating methods for the analysis of cefprozil in the presence of its alkaline induced degradation product

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed

    2016-04-01

    Three simple, specific, accurate and precise spectrophotometric methods were developed for the determination of cefprozil (CZ) in the presence of its alkaline induced degradation product (DCZ). The first method was the bivariate method, while the two other multivariate methods were partial least squares (PLS) and spectral residual augmented classical least squares (SRACLS). The multivariate methods were applied with and without variable selection procedure (genetic algorithm GA). These methods were tested by analyzing laboratory prepared mixtures of the above drug with its alkaline induced degradation product and they were applied to its commercial pharmaceutical products.

  6. Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.

    ERIC Educational Resources Information Center

    Pike, R. M.; And Others

    1986-01-01

    Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)

  7. Visual conspicuity: a new simple standard, its reliability, validity and applicability.

    PubMed

    Wertheim, A H

    2010-03-01

    A general standard for quantifying conspicuity is described. It derives from a simple and easy method to quantitatively measure the visual conspicuity of an object. The method stems from the theoretical view that the conspicuity of an object is not a property of that object, but describes the degree to which the object is perceptually embedded in, i.e. laterally masked by, its visual environment. First, three variations of a simple method to measure the strength of such lateral masking are described and empirical evidence for its reliability and its validity is presented, as are several tests of predictions concerning the effects of viewing distance and ambient light. It is then shown how this method yields a conspicuity standard, expressed as a number, which can be made part of a rule of law, and which can be used to test whether or not, and to what extent, the conspicuity of a particular object, e.g. a traffic sign, meets a predetermined criterion. An additional feature is that, when used under different ambient light conditions, the method may also yield an index of the amount of visual clutter in the environment. Taken together the evidence illustrates the methods' applicability in both the laboratory and in real-life situations. STATEMENT OF RELEVANCE: This paper concerns a proposal for a new method to measure visual conspicuity, yielding a numerical index that can be used in a rule of law. It is of importance to ergonomists and human factor specialists who are asked to measure the conspicuity of an object, such as a traffic or rail-road sign, or any other object. The new method is simple and circumvents the need to perform elaborate (search) experiments and thus has great relevance as a simple tool for applied research.

  8. Simple Sodium Dodecyl Sulfate-Assisted Sample Preparation Method for LC-MS-based Proteomic Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Jianying; Dann, Geoffrey P.; Shi, Tujin

    2012-03-10

    Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides.more » Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.« less

  9. Comparison of the dye method with the thermocouple psychrometer for measuring leaf water potentials.

    PubMed

    Knipling, E B; Kramer, P J

    1967-10-01

    The dye method for measuring water potential was examined and compared with the thermocouple psychrometer method in order to evaluate its usefulness for measuring leaf water potentials of forest trees and common laboratory plants. Psychrometer measurements are assumed to represent the true leaf water potentials. Because of the contamination of test solutions by cell sap and leaf surface residues, dye method values of most species varied about 1 to 5 bars from psychrometer values over the leaf water potential range of 0 to -30 bars. The dye method is useful for measuring changes and relative values in leaf potential. Because of species differences in the relationships of dye method values to true leaf water potentials, dye method values should be interpreted with caution when comparing different species or the same species growing in widely different environments. Despite its limitations the dye method has a usefulness to many workers because it is simple, requires no elaborate equipment, and can be used in both the laboratory and field.

  10. [Differentiation of species within the Mycobacterium tuberculosis complex by molecular techniques].

    PubMed

    Herrera-León, Laura; Pozuelo-Díaz, Rodolfo; Molina Moreno, Tamara; Valverde Cobacho, Azucena; Saiz Vega, Pilar; Jiménez Pajares, María Soledad

    2009-11-01

    The Mycobacterium tuberculosis complex includes the following species: Mycobacterium tuberculosis, Mycobacterium africanum, Mycobacterium bovis, Mycobacterium bovis-BCG, Mycobacterium microti, Mycobacterium caprae, Mycobacterium pinnipedii, and Mycobacterium canettii. These species cause tuberculosis in humans and animals. Identification of mycobacterial strains has classically been performed by phenotype study. Over the last years, laboratories have developed several molecular techniques to differentiate between these species. The aim of this study is to evaluate these methods and develop a simple, fast, identification scheme. We analyzed 251 strains randomly obtained from the strains studied in 2004, and 797 strains received by the Reference Laboratory between 2005 and 2007. Phenotype characterization of 4183 strains isolated during that period was done by studying the colony morphology, characteristics in culture, nitrate reduction, niacin accumulation, and growth in the presence of thiophen-2-carboxylic acid hydrazide 10 microg/mL and pyrazinamide 50 microg/mL. The molecular identification scheme designed was as follows: 1) gyrB PCR-RFLP with RsaI, TaqI or SacII and hsp65 RFLP/PCR with HhaI., and 2) multiplex-PCR to determine the presence/absence of the RD9 and RD1 regions. The results showed 100% agreement between phenotype study and the molecular scheme. This molecular identification scheme is a simple and fast method, with 100% sensitivity and specificity, that can be implemented in most clinical laboratories at a low cost.

  11. Capacitance Sensor For Nondestructive Determination Of Total Oil Content In Nuts

    USDA-ARS?s Scientific Manuscript database

    Earlier a simple, low cost instrument was designed and assembled in our laboratory, that could estimate the moisture content (MC) of in-shell peanuts (MC range 9% to 20%) and yellow-dent field corn (MC range 7% to 18%). In this method a sample of of in-shell peanuts or corn was placed between a set...

  12. Dimensional Analysis in Mathematical Modeling Systems: A Simple Numerical Method

    DTIC Science & Technology

    1991-02-01

    US Army Ballistic Research Laboratories, Aberden Proving Ground , NID, August 1975. [18] Hi1irlimann, T., and .J. lKohlas "LPL: A Structured Language...such systems can prove that (a’ + ab + b2 + ba) = (a + b) 2 . With some effort, since the laws of physical algebra are a minor variant on those of

  13. An Authentic Research Experience for Undergraduates on a Budget: Using Data from Simple Experiments to Develop Mini-Research Proposals

    ERIC Educational Resources Information Center

    Robertson, Katherine

    2016-01-01

    The benefits of undergraduate research are well documented, and many colleges and universities include a senior research requirement for graduation. In addition, most science curricula attempt to include discoverystyle, laboratory components to prepare students for their research experiences and to expose them to research methods in different…

  14. Using a Simple "Escherichia Coli" Growth Curve Model to Teach the Scientific Method

    ERIC Educational Resources Information Center

    McKernan, Lisa N.

    2015-01-01

    The challenge of teaching in the sciences is not only conveying knowledge in the discipline, but also developing essential critical thinking, data analysis, and scientific writing skills. I outline an exercise that can be done easily as part of a microbiology laboratory course. It teaches the nature of the research process, from asking questions…

  15. Simple Methods for Production of Nanoscale Metal Oxide Films from Household Sources

    ERIC Educational Resources Information Center

    Campbell, Dean J.; Baliss, Michelle S.; Hinman, Jordan J.; Ziegenhorn, John W.; Andrews, Mark J.; Stevenson, Keith J.

    2013-01-01

    Production of thin metal oxide films was recently explored as part of an outreach program with a goal of producing nanoscale structures with household items. Household items coated with various metals or titanium compounds can be heated to produce colorful films with nanoscale thicknesses. As part of a materials chemistry laboratory experiment…

  16. Practical estimates of field-saturated hydraulic conductivity of bedrock outcrops using a modified bottomless bucket method

    USGS Publications Warehouse

    Mirus, Benjamin B.; Perkins, Kim S.

    2012-01-01

    The bottomless bucket (BB) approach (Nimmo et al., 2009a) is a cost-effective method for rapidly characterizing field-saturated hydraulic conductivity Kfs of soils and alluvial deposits. This practical approach is of particular value for quantifying infiltration rates in remote areas with limited accessibility. A similar approach for bedrock outcrops is also of great value for improving quantitative understanding of infiltration and recharge in rugged terrain. We develop a simple modification to the BB method for application to bedrock outcrops, which uses a non-toxic, quick-drying silicone gel to seal the BB to the bedrock. These modifications to the field method require only minor changes to the analytical solution for calculating Kfs on soils. We investigate the reproducibility of the method with laboratory experiments on a previously studied calcarenite rock and conduct a sensitivity analysis to quantify uncertainty in our predictions. We apply the BB method on both bedrock and soil for sites on Pahute Mesa, which is located in a remote area of the Nevada National Security Site. The bedrock BB tests may require monitoring over several hours to days, depending on infiltration rates, which necessitates a cover to prevent evaporative losses. Our field and laboratory results compare well to Kfs values inferred from independent reports, which suggests the modified BB method can provide useful estimates and facilitate simple hypothesis testing. The ease with which the bedrock BB method can be deployed should facilitate more rapid in-situ data collection than is possible with alternative methods for quantitative characterization of infiltration into bedrock.

  17. Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities

    PubMed Central

    Parsons, Linda M.; Somoskövi, Ákos; Gutierrez, Cristina; Lee, Evan; Paramasivan, C. N.; Abimiku, Alash'le; Spector, Steven; Roscigno, Giorgio; Nkengasong, John

    2011-01-01

    Summary: With an estimated 9.4 million new cases globally, tuberculosis (TB) continues to be a major public health concern. Eighty percent of all cases worldwide occur in 22 high-burden, mainly resource-poor settings. This devastating impact of tuberculosis on vulnerable populations is also driven by its deadly synergy with HIV. Therefore, building capacity and enhancing universal access to rapid and accurate laboratory diagnostics are necessary to control TB and HIV-TB coinfections in resource-limited countries. The present review describes several new and established methods as well as the issues and challenges associated with implementing quality tuberculosis laboratory services in such countries. Recently, the WHO has endorsed some of these novel methods, and they have been made available at discounted prices for procurement by the public health sector of high-burden countries. In addition, international and national laboratory partners and donors are currently evaluating other new diagnostics that will allow further and more rapid testing in point-of-care settings. While some techniques are simple, others have complex requirements, and therefore, it is important to carefully determine how to link these new tests and incorporate them within a country's national diagnostic algorithm. Finally, the successful implementation of these methods is dependent on key partnerships in the international laboratory community and ensuring that adequate quality assurance programs are inherent in each country's laboratory network. PMID:21482728

  18. Metal-assisted chemical etching using sputtered gold: a simple route to black silicon

    NASA Astrophysics Data System (ADS)

    Kurek, Agnieszka; Barry, Seán T.

    2011-08-01

    We report an accessible and simple method of producing 'black silicon' with aspect ratios as high as 8 using common laboratory equipment. Gold was sputtered to a thickness of 8 nm using a low-vacuum sputter coater. The structures were etched into silicon substrates using an aqueous H2O2/HF solution, and the gold was then removed using aqua regia. Ultrasonication was necessary to produce columnar structures, and an etch time of 24 min gave a velvety, non-reflective surface. The surface features after 24 min etching were uniformly microstructured over an area of square centimetres.

  19. [Preservation of fungi and actinomycetes of medical importance in distilled water].

    PubMed

    Rodrigues, E G; Lírio, V S; Lacaz, C da S

    1992-01-01

    Several methods have been used for the preservation of fungi, all of them presenting advantages and disadvantages. The choice of the methods depends upon the laboratory availabilities, time of preservation, genetic stability of the cultures and other factors. In this work the results obtained through the utilization of Castellani's method (preservation in distilled water) for the maintenance of 174 strains belonging to the "Micoteca do Instituto de Medicina Tropical de São Paulo" are presented. These strains were analyzed after 6, 12, 18 and 24 months, with regard to the percentage of viability taking into consideration the rates of growth and contamination. The smallest percentage of viability occurred in the group of the actinomycetes (50 to 100%) and the largest one in the group of the yeasts (near 100%). According to other authors, the Castellani's method, besides being simple and economically feasible for small size laboratories, yields good results.

  20. A cost-efficient frequency-domain photoacoustic imaging system

    PubMed Central

    LeBoulluec, Peter; Liu, Hanli; Yuan, Baohong

    2013-01-01

    Photoacoustic (PA) imaging techniques have recently attracted much attention and can be used for noninvasive imaging of biological tissues. Most PA imaging systems in research laboratories use the time domain method with expensive nanosecond pulsed lasers that are not affordable for most educational laboratories. Using an intensity modulated light source to excite PA signals is an alternative technique, known as the frequency domain method, with a much lower cost. In this paper, we describe a simple frequency domain PA system and demonstrate its imaging capability. The system provides opportunities not only to observe PA signals in tissue phantoms, but also to acquire hands-on skills in PA signal detection. It also provides opportunities to explore the underlying mechanisms of the PA effect. PMID:24659823

  1. [The brain in stereotaxic coordinates (a textbook for colleges)].

    PubMed

    Budantsev, A Iu; Kisliuk, O S; Shul'govskiĭ, V V; Rykunov, D S; Iarkov, A V

    1993-01-01

    The present textbook is directed forward students of universities and medical colleges, young scientists and practicing doctors dealing with stereotaxic method. The Paxinos and Watson stereotaxic rat brain atlas (1982) is the basis of the textbook. The atlas has been transformed into computer educational program and seven laboratory works: insertion of the electrode into brain, microelectrophoresis, microinjection of drugs into brain, electrolytic destruction in the brain structures, local brain superfusion. The laboratory works are compiled so that they allow not only to study practical use of the stereotaxic method but to model simple problems involving stereotaxic surgery in the deep structures of brain. The textbook is intended for carrying by IBM PC/AT computers. The volume of the textbook is 1.7 Mbytes.

  2. A cost-efficient frequency-domain photoacoustic imaging system.

    PubMed

    Leboulluec, Peter; Liu, Hanli; Yuan, Baohong

    2013-09-01

    Photoacoustic (PA) imaging techniques have recently attracted much attention and can be used for noninvasive imaging of biological tissues. Most PA imaging systems in research laboratories use the time domain method with expensive nanosecond pulsed lasers that are not affordable for most educational laboratories. Using an intensity modulated light source to excite PA signals is an alternative technique, known as the frequency domain method, with a much lower cost. In this paper, we describe a simple frequency domain PA system and demonstrate its imaging capability. The system provides opportunities not only to observe PA signals in tissue phantoms, but also to acquire hands-on skills in PA signal detection. It also provides opportunities to explore the underlying mechanisms of the PA effect.

  3. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    PubMed

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  4. [Establishing biological reference intervals of alanine transaminase for clinical laboratory stored database].

    PubMed

    Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen

    2015-08-25

    To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.

  5. Secrets of the Chinese magic mirror replica

    NASA Astrophysics Data System (ADS)

    Mak, Se-yuen; Yip, Din-yan

    2001-03-01

    We examine the structure of five Chinese magic mirror replicas using a special imaging technique developed by the authors. All mirrors are found to have a two-layered structure. The reflecting surface that gives rise to a projected magic pattern on the screen is hidden under a polished half-reflecting top layer. An alternative method of making the magic mirror using ancient technology has been proposed. Finally, we suggest a simple method of reconstructing a mirror replica in the laboratory.

  6. Exponential Formulae and Effective Operations

    NASA Technical Reports Server (NTRS)

    Mielnik, Bogdan; Fernandez, David J. C.

    1996-01-01

    One of standard methods to predict the phenomena of squeezing consists in splitting the unitary evolution operator into the product of simpler operations. The technique, while mathematically general, is not so simple in applications and leaves some pragmatic problems open. We report an extended class of exponential formulae, which yield a quicker insight into the laboratory details for a class of squeezing operations, and moreover, can be alternatively used to programme different type of operations, as: (1) the free evolution inversion; and (2) the soft simulations of the sharp kicks (so that all abstract results involving the kicks of the oscillator potential, become realistic laboratory prescriptions).

  7. Low-cost nonlinear optics experiment for undergraduate instructional laboratory and lecture demonstration

    NASA Astrophysics Data System (ADS)

    Turchiello, Rozane de F.; Pereira, Luiz A. A.; Gómez, Sergio L.

    2017-07-01

    This paper presents a simple and affordable experiment on the thermal lens effect, suitable for an undergraduate educational laboratory or as a tabletop demonstration in a lecture on nonlinear optics. Such an experiment exploits the formation of a lens in an absorbing medium illuminated by a laser beam with a Gaussian intensity profile. As an absorber, we use a commercial soy sauce, which exhibits a strong thermal lensing effect. Additionally, we show how to measure the radius of a Gaussian beam using the knife-edge method, and how to estimate the focal length of the induced thermal lens.

  8. Development and single-laboratory validation of a UHPLC-MS/MS method for quantitation of microcystins and nodularin in natural water, cyanobacteria, shellfish and algal supplement tablet powders.

    PubMed

    Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda

    2018-02-01

    A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new method, now accredited to ISO17025 standard, is simple, quick, applicable to multiple matrices and is highly suitable for use as a routine, high-throughout, fast turnaround regulatory monitoring tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A Simple Low-Cost Lock-In Amplifier for the Laboratory

    ERIC Educational Resources Information Center

    Sengupta, Sandip K.; Farnham, Jessica M.; Whitten, James E.

    2005-01-01

    The creation of a simple, low-cost lock-in amplifier (LIA) suitable for use in the chemistry teaching laboratory is described. The use of integrated circuits and few components are necessary to adequately accomplish lock-in amplification limited the total cost of construction to under US$100.

  10. A simple technique for maintaining Stimulium adults, including onchocerciasis vectors, under artificial conditions.

    PubMed

    Raybould, J N; Mhiddin, H K

    1974-01-01

    The maintenance of Simulium adults in the laboratory is necessary for many experimental investigations and is a prerequisite to laboratory colonization. A simple technique for this purpose is described in which each fly is kept separately in a hole bored in a block of expanded polystyrene.

  11. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    PubMed

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  12. Development and Validation of a Fast Procedure to Analyze Amoxicillin in River Waters by Direct-Injection LC-MS/MS

    ERIC Educational Resources Information Center

    Homem, Vera; Alves, Arminda; Santos, Lu´cia

    2014-01-01

    A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…

  13. Achieving Very Low Levels of Detection: An Improved Surface-Enhanced Raman Scattering Experiment for the Physical Chemistry Teaching Laboratory

    ERIC Educational Resources Information Center

    McMillan, Brian G.

    2016-01-01

    This experiment was designed and successfully introduced to complement the nanochemistry taught to undergraduate students in a useful and interesting way. Colloidal Ag nanoparticles were synthesized by a simple, room-temperature method, and the resulting suspension was then used to study the surface-enhanced Raman scattering (SERS) of methylene…

  14. Carbon Dioxide Absorbers: An Engaging Experiment for the General Chemistry Laboratory

    ERIC Educational Resources Information Center

    Ticich, Thomas M.

    2011-01-01

    A simple and direct method for measuring the absorption of carbon dioxide by two different substances is described. Lithium hydroxide has been used for decades to remove the gas from enclosed living spaces, such as spacecraft and submarines. The ratio of the mass of carbon dioxide absorbed to the mass of lithium hydroxide used obtained from this…

  15. The Zymogen-Enteropeptidase System: A Practical Approach to Study the Regulation of Enzyme Activity by Proteolytic Cleavage

    ERIC Educational Resources Information Center

    Pizauro, Joao M., Jr.; Ferro, Jesus A.; de Lima, Andrea C. F.; Routman, Karina S.; Portella, Maria Celia

    2004-01-01

    The present research describes an efficient procedure to obtain high levels of trypsinogen and chymotrypsinogen by using a simple, rapid, and easily reproducible method. The extraction process and the time-course of activation of zymogens can be carried out in a single laboratory period, without sophisticated equipment. The main objective was to…

  16. Comments on "Speed of Sound in Metal Pipes: An Inexpensive Lab"

    ERIC Educational Resources Information Center

    Blodgett, Earl D.

    2009-01-01

    In a recent article Huggins outlines a very simple method of measuring the speed of sound in metal pipes by striking one end with a hammer and recording the transit time as the resultant pulse echoes back and forth. We immediately adapted this for use in an introductory laboratory where we are familiarizing students with the measurement of…

  17. A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis

    PubMed Central

    Kaduri, Maya; Shainsky-Roitman, Janna; Goldfeder, Mor; Ivanir, Eran; Benhar, Itai; Shoham, Yuval; Schroeder, Avi

    2016-01-01

    Cell-free protein synthesis (CFPS) systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3) and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa). This system was able to produce 40–150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins. PMID:27768741

  18. Conditions of High Resolution Melting Analysis on the Cobas z480 Instrument for the Genotyping of VKORC1 in the Clinical Routine Laboratory.

    PubMed

    Paar, Christian; Hammerl, Verena; Blessberger, Hermann; Stekel, Herbert; Steinwender, Clemens; Berg, Jörg

    2016-12-01

    High resolution melting (HRM) of amplicons is a simple method for genotyping of single nucleotide polymorphisms (SNPs). Albeit many applications reported, HRM seems to be rarely used in clinical laboratories. The suitability of HRM-PCR for the clinical laboratory was investigated for genotyping of SNPs of the vitamin K epoxide reductase complex unit 1 gene. About 100 DNA samples were analyzed by two different HRM-PCRs on the Cobas z480 instrument and compared with a PCR with fluorescently labeled probes (HybProbe-PCR) on the LightCycler 2.0 instrument as reference. Reliable genotyping with 100% matching results was obtained, when the amplicon size was small (63 bp) and DNA input was limited by e.g., sample dilution with salt-free water. DNA extracted by differing methods may be used for genotyping by HRM-PCR. Compared with HybProbe-PCR, HRM-PCR on the Cobas z480 instrument allows for higher through-put, however, at the cost of a higher degree of laboratory standardization and a slower turnaround.

  19. Simple, Rapid, and Selective Isolation of 2S Albumins from Allergenic Seeds and Nuts.

    PubMed

    Hummel, Marlene; Wigger, Tina; Höper, Tessa; Westkamp, Imke; Brockmeyer, Jens

    2015-07-08

    The 2S albumins belong to the group of seed storage proteins present in different seeds and nuts. Due to their pronounced allergenic potential, which is often associated with severe allergic reactions, this protein family is of special interest in the field of allergen research. Here we present a simple, rapid, and selective method for the purification of 2S albumins directly from allergenic seeds and nuts. We systematically optimized the parameters "buffer system", "extraction temperature", "buffer molarity", and "pH " and were able to achieve 2S albumin purities of about 99% without further purification and demonstrate transferability of this method to nine different allergenic food matrices. Compared to conventional isolation routines, significant reduction of hands-on time and required laboratory equipment is achieved, but nonetheless higher protein yields are obtained. The presented method allows for the rapid purification of different 2S albumins including the corresponding isoforms from natural material.

  20. Method for evaluation of laboratory craters using crater detection algorithm for digital topography data

    NASA Astrophysics Data System (ADS)

    Salamunićcar, Goran; Vinković, Dejan; Lončarić, Sven; Vučina, Damir; Pehnec, Igor; Vojković, Marin; Gomerčić, Mladen; Hercigonja, Tomislav

    In our previous work the following has been done: (1) the crater detection algorithm (CDA) based on digital elevation model (DEM) has been developed and the GT-115225 catalog has been assembled [GRS, 48 (5), in press, doi:10.1109/TGRS.2009.2037750]; and (2) the results of comparison between explosion-induced laboratory craters in stone powder surfaces and GT-115225 have been presented using depth/diameter measurements [41stLPSC, Abstract #1428]. The next step achievable using the available technology is to create 3D scans of such labo-ratory craters, in order to compare different properties with simple Martian craters. In this work, we propose a formal method for evaluation of laboratory craters, in order to provide objective, measurable and reproducible estimation of the level of achieved similarity between these laboratory and real impact craters. In the first step, the section of MOLA data for Mars (or SELENE LALT for Moon) is replaced with one or several 3D-scans of laboratory craters. Once embedment was done, the CDA can be used to find out whether this laboratory crater is similar enough to real craters, as to be recognized as a crater by the CDA. The CDA evaluation using ROC' curve represents how true detection rate (TDR=TP/(TP+FN)=TP/GT) depends on the false detection rate (FDR=FP/(TP+FP)). Using this curve, it is now possible to define the measure of similarity between laboratory and real impact craters, as TDR or FDR value, or as a distance from the bottom-right origin of the ROC' curve. With such an approach, the reproducible (formally described) method for evaluation of laboratory craters is provided.

  1. Virtual Passive Controller for Robot Systems Using Joint Torque Sensors

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    This paper presents a control method based on virtual passive dynamic control that will stabilize a robot manipulator using joint torque sensors and a simple joint model. The method does not require joint position or velocity feedback for stabilization. The proposed control method is stable in the sense of Lyaponov. The control method was implemented on several joints of a laboratory robot. The controller showed good stability robustness to system parameter error and to the exclusion of nonlinear dynamic effects on the joints. The controller enhanced position tracking performance and, in the absence of position control, dissipated joint energy.

  2. Simple algorithms for remote determination of mineral abundances and particle sizes from reflectance spectra

    NASA Technical Reports Server (NTRS)

    Johnson, Paul E.; Smith, Milton O.; Adams, John B.

    1992-01-01

    Algorithms were developed, based on Hapke's (1981) equations, for remote determinations of mineral abundances and particle sizes from reflectance spectra. In this method, spectra are modeled as a function of end-member abundances and illumination/viewing geometry. The method was tested on a laboratory data set. It is emphasized that, although there exist more sophisticated models, the present algorithms are particularly suited for remotely sensed data, where little opportunity exists to independently measure reflectance versus article size and phase function.

  3. Visualization of small lesions in rat cartilage by means of laboratory-based x-ray phase contrast imaging

    NASA Astrophysics Data System (ADS)

    Marenzana, Massimo; Hagen, Charlotte K.; Das Neves Borges, Patricia; Endrizzi, Marco; Szafraniec, Magdalena B.; Ignatyev, Konstantin; Olivo, Alessandro

    2012-12-01

    Being able to quantitatively assess articular cartilage in three-dimensions (3D) in small rodent animal models, with a simple laboratory set-up, would prove extremely important for the development of pre-clinical research focusing on cartilage pathologies such as osteoarthritis (OA). These models are becoming essential tools for the development of new drugs for OA, a disease affecting up to 1/3 of the population older than 50 years for which there is no cure except prosthetic surgery. However, due to limitations in imaging technology, high-throughput 3D structural imaging has not been achievable in small rodent models, thereby limiting their translational potential and their efficiency as research tools. We show that a simple laboratory system based on coded-aperture x-ray phase contrast imaging (CAXPCi) can correctly visualize the cartilage layer in slices of an excised rat tibia imaged both in air and in saline solution. Moreover, we show that small, surgically induced lesions are also correctly detected by the CAXPCi system, and we support this finding with histopathology examination. Following these successful proof-of-concept results in rat cartilage, we expect that an upgrade of the system to higher resolutions (currently underway) will enable extending the method to the imaging of mouse cartilage as well. From a technological standpoint, by showing the capability of the system to detect cartilage also in water, we demonstrate phase sensitivity comparable to other lab-based phase methods (e.g. grating interferometry). In conclusion, CAXPCi holds a strong potential for being adopted as a routine laboratory tool for non-destructive, high throughput assessment of 3D structural changes in murine articular cartilage, with a possible impact in the field similar to the revolution that conventional microCT brought into bone research.

  4. BASIC: A Simple and Accurate Modular DNA Assembly Method.

    PubMed

    Storch, Marko; Casini, Arturo; Mackrow, Ben; Ellis, Tom; Baldwin, Geoff S

    2017-01-01

    Biopart Assembly Standard for Idempotent Cloning (BASIC) is a simple, accurate, and robust DNA assembly method. The method is based on linker-mediated DNA assembly and provides highly accurate DNA assembly with 99 % correct assemblies for four parts and 90 % correct assemblies for seven parts [1]. The BASIC standard defines a single entry vector for all parts flanked by the same prefix and suffix sequences and its idempotent nature means that the assembled construct is returned in the same format. Once a part has been adapted into the BASIC format it can be placed at any position within a BASIC assembly without the need for reformatting. This allows laboratories to grow comprehensive and universal part libraries and to share them efficiently. The modularity within the BASIC framework is further extended by the possibility of encoding ribosomal binding sites (RBS) and peptide linker sequences directly on the linkers used for assembly. This makes BASIC a highly versatile library construction method for combinatorial part assembly including the construction of promoter, RBS, gene variant, and protein-tag libraries. In comparison with other DNA assembly standards and methods, BASIC offers a simple robust protocol; it relies on a single entry vector, provides for easy hierarchical assembly, and is highly accurate for up to seven parts per assembly round [2].

  5. Use of next generation sequencing data to develop a qPCR method for specific detection of EU-unauthorized genetically modified Bacillus subtilis overproducing riboflavin.

    PubMed

    Barbau-Piednoir, Elodie; De Keersmaecker, Sigrid C J; Delvoye, Maud; Gau, Céline; Philipp, Patrick; Roosens, Nancy H

    2015-11-11

    Recently, the presence of an unauthorized genetically modified (GM) Bacillus subtilis bacterium overproducing vitamin B2 in a feed additive was notified by the Rapid Alert System for Food and Feed (RASFF). This has demonstrated that a contamination by a GM micro-organism (GMM) may occur in feed additives and has confronted for the first time,the enforcement laboratories with this type of RASFF. As no sequence information of this GMM nor any specific detection or identification method was available, Next GenerationSequencing (NGS) was used to generate sequence information. However, NGS data analysis often requires appropriate tools, involving bioinformatics expertise which is not alwayspresent in the average enforcement laboratory. This hampers the use of this technology to rapidly obtain critical sequence information in order to be able to develop a specific qPCRdetection method. Data generated by NGS were exploited using a simple BLAST approach. A TaqMan® qPCR method was developed and tested on isolated bacterial strains and on the feed additive directly. In this study, a very simple strategy based on the common BLAST tools that can be used by any enforcement lab without profound bioinformatics expertise, was successfully used toanalyse the B. subtilis data generated by NGS. The results were used to design and assess a new TaqMan® qPCR method, specifically detecting this GM vitamin B2 overproducing bacterium. The method complies with EU critical performance parameters for specificity, sensitivity, PCR efficiency and repeatability. The VitB2-UGM method also could detect the B. subtilis strain in genomic DNA extracted from the feed additive, without prior culturing step. The proposed method, provides a crucial tool for specifically and rapidly identifying this unauthorized GM bacterium in food and feed additives by enforcement laboratories. Moreover, this work can be seen as a case study to substantiate how the use of NGS data can offer an added value to easily gain access to sequence information needed to develop qPCR methods to detect unknown andunauthorized GMO in food and feed.

  6. An evolutionary view of chromatography data systems used in bioanalysis.

    PubMed

    McDowall, R D

    2010-02-01

    This is a personal view of how chromatographic peak measurement and analyte quantification for bioanalysis have evolved from the manual methods of 1970 to the electronic working possible in 2010. In four decades there have been major changes from a simple chart recorder output (that was interpreted and quantified manually) through simple automation of peak measurement, calculation of standard curves and quality control values and instrument control to the networked chromatography data systems of today that are capable of interfacing with Laboratory Information Management Systems and other IT applications. The incorporation of electronic signatures to meet regulatory requirements offers a great opportunity for business improvement and electronic working.

  7. A simple method for the construction of small format tissue arrays

    PubMed Central

    Hidalgo, A; Piña, P; Guerrero, G; Lazos, M; Salcedo, M

    2003-01-01

    Tissue arrays can evaluate molecular targets in high numbers of samples in parallel. Array construction presents technical difficulties and tissue arrayers are expensive, particularly for small and medium sized laboratories. This report describes a method for the construction of 36 sample arrays using widely available materials. A blunted 16 gauge needle for bone marrow aspiration was used to extract paraffin wax cylinders and manually define a 6 × 6 matrix on a blank paraffin wax block. Tissue cores from 36 paraffin wax embedded premalignant lesions and invasive cervical carcinomas were injected into the matrix using a 14 gauge needle. This tissue array was sectioned using a standard microtome and used for the immunodetection of CD44 variant 9 and interleukin 18 with satisfactory results. This method can be applied in any laboratory, without the need of specialised equipment, offering a good alternative for the wider application of tissue arrays. PMID:12560397

  8. Comparison of the Dye Method with the Thermocouple Psychrometer for Measuring Leaf Water Potentials 1

    PubMed Central

    Knipling, Edward B.; Kramer, Paul J.

    1967-01-01

    The dye method for measuring water potential was examined and compared with the thermocouple psychrometer method in order to evaluate its usefulness for measuring leaf water potentials of forest trees and common laboratory plants. Psychrometer measurements are assumed to represent the true leaf water potentials. Because of the contamination of test solutions by cell sap and leaf surface residues, dye method values of most species varied about 1 to 5 bars from psychrometer values over the leaf water potential range of 0 to −30 bars. The dye method is useful for measuring changes and relative values in leaf potential. Because of species differences in the relationships of dye method values to true leaf water potentials, dye method values should be interpreted with caution when comparing different species or the same species growing in widely different environments. Despite its limitations the dye method has a usefulness to many workers because it is simple, requires no elaborate equipment, and can be used in both the laboratory and field. PMID:16656657

  9. Numerical modeling of zero-offset laboratory data in a strong topographic environment: results for a spectral-element method and a discretized Kirchhoff integral method

    NASA Astrophysics Data System (ADS)

    Favretto-Cristini, Nathalie; Tantsereva, Anastasiya; Cristini, Paul; Ursin, Bjørn; Komatitsch, Dimitri; Aizenberg, Arkady M.

    2014-08-01

    Accurate simulation of seismic wave propagation in complex geological structures is of particular interest nowadays. However conventional methods may fail to simulate realistic wavefields in environments with great and rapid structural changes, due for instance to the presence of shadow zones, diffractions and/or edge effects. Different methods, developed to improve seismic modeling, are typically tested on synthetic configurations against analytical solutions for simple canonical problems or reference methods, or via direct comparison with real data acquired in situ. Such approaches have limitations, especially if the propagation occurs in a complex environment with strong-contrast reflectors and surface irregularities, as it can be difficult to determine the method which gives the best approximation of the "real" solution, or to interpret the results obtained without an a priori knowledge of the geologic environment. An alternative approach for seismics consists in comparing the synthetic data with high-quality data collected in laboratory experiments under controlled conditions for a known configuration. In contrast with numerical experiments, laboratory data possess many of the characteristics of field data, as real waves propagate through models with no numerical approximations. We thus present a comparison of laboratory-scaled measurements of 3D zero-offset wave reflection of broadband pulses from a strong topographic environment immersed in a water tank with numerical data simulated by means of a spectral-element method and a discretized Kirchhoff integral method. The results indicate a good quantitative fit in terms of time arrivals and acceptable fit in amplitudes for all datasets.

  10. Development of flexural vibration inspection techniques to rapidly assess the structural health of timber bridge systems

    Treesearch

    Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw; Robert Vatalaro

    2005-01-01

    This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...

  11. Evaluation of various soil water samplers for virological sampling.

    PubMed Central

    Wang, D S; Lance, J C; Gerba, C P

    1980-01-01

    Two commercially available soil water samplers and a ceramic sampler constructed in our laboratories were evaluated for their ability to recover viruses from both tap water and secondary sewage effluent. The ceramic sampler consistently gave the best recoveries of viruses from water samples. Soil columns containing ceramic samplers at various depths provide a simple method for studying virus transport through sewage-contaminated soils. Images PMID:6247976

  12. Developing and Implementing a Simple, Affordable Hydrogen Fuel Cell Laboratory in Introductory Chemistry

    ERIC Educational Resources Information Center

    Klara, Kristina; Hou, Ning; Lawman, Allison; Wu, Liheng; Morrill, Drew; Tente, Alfred; Wang, Li-Qiong

    2014-01-01

    A simple, affordable hydrogen proton exchange membrane (PEM) fuel cell laboratory was developed through a collaborative effort between faculty and undergraduate students at Brown University. It has been incorporated into the introductory chemistry curriculum and successfully implemented in a class of over 500 students per academic year for over 3…

  13. A simple technique for maintaining Simulium adults, including onchocerciasis vectors, under artificial conditions*

    PubMed Central

    Raybould, John N.; Mhiddin, Haji K.

    1974-01-01

    The maintenance of Simulium adults in the laboratory is necessary for many experimental investigations and is a prerequisite to laboratory colonization. A simple technique for this purpose is described in which each fly is kept separately in a hole bored in a block of expanded polystyrene. ImagesFig. 1 PMID:4549353

  14. Screening and monitoring microbial xenobiotics' biodegradation by rapid, inexpensive and easy to perform microplate UV-absorbance measurements.

    PubMed

    Herzog, Bastian; Lemmer, Hilde; Horn, Harald; Müller, Elisabeth

    2014-02-22

    Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. In laboratory setups, xenobiotics concentrations above 1.0 mg L(-1) without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum.

  15. Screening and monitoring microbial xenobiotics’ biodegradation by rapid, inexpensive and easy to perform microplate UV-absorbance measurements

    PubMed Central

    2014-01-01

    Background Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. Results The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. Conclusions In laboratory setups, xenobiotics concentrations above 1.0 mg L-1 without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum. PMID:24558966

  16. What’s in a drop? Correlating observations and outcomes to guide macromolecular crystallization experiments

    PubMed Central

    Luft, Joseph R.; Wolfley, Jennifer R.; Snell, Edward H.

    2011-01-01

    Observations of crystallization experiments are classified as specific outcomes and integrated through a phase diagram to visualize solubility and thereby direct subsequent experiments. Specific examples are taken from our high-throughput crystallization laboratory which provided a broad scope of data from 20 million crystallization experiments on 12,500 different biological macromolecules. The methods and rationale are broadly and generally applicable in any crystallization laboratory. Through a combination of incomplete factorial sampling of crystallization cocktails, standard outcome classifications, visualization of outcomes as they relate chemically and application of a simple phase diagram approach we demonstrate how to logically design subsequent crystallization experiments. PMID:21643490

  17. Alternative methods to determine headwater benefits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bao, Y.S.; Perlack, R.D.; Sale, M.J.

    1997-11-10

    In 1992, the Federal Energy Regulatory Commission (FERC) began using a Flow Duration Analysis (FDA) methodology to assess headwater benefits in river basins where use of the Headwater Benefits Energy Gains (HWBEG) model may not result in significant improvements in modeling accuracy. The purpose of this study is to validate the accuracy and appropriateness of the FDA method for determining energy gains in less complex basins. This report presents the results of Oak Ridge National Laboratory`s (ORNL`s) validation of the FDA method. The validation is based on a comparison of energy gains using the FDA method with energy gains calculatedmore » using the MWBEG model. Comparisons of energy gains are made on a daily and monthly basis for a complex river basin (the Alabama River Basin) and a basin that is considered relatively simple hydrologically (the Stanislaus River Basin). In addition to validating the FDA method, ORNL was asked to suggest refinements and improvements to the FDA method. Refinements and improvements to the FDA method were carried out using the James River Basin as a test case.« less

  18. Inter-laboratory validation of an inexpensive streamlined method to measure inorganic arsenic in rice grain.

    PubMed

    Chaney, Rufus L; Green, Carrie E; Lehotay, Steven J

    2018-05-04

    With the establishment by CODEX of a 200 ng/g limit of inorganic arsenic (iAs) in polished rice grain, more analyses of iAs will be necessary to ensure compliance in regulatory and trade applications, to assess quality control in commercial rice production, and to conduct research involving iAs in rice crops. Although analytical methods using high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) have been demonstrated for full speciation of As, this expensive and time-consuming approach is excessive when regulations are based only on iAs. We report a streamlined sample preparation and analysis of iAs in powdered rice based on heated extraction with 0.28 M HNO 3 followed by hydride generation (HG) under control of acidity and other simple conditions. Analysis of iAs is then conducted using flow-injection HG and inexpensive ICP-atomic emission spectroscopy (AES) or other detection means. A key innovation compared with previous methods was to increase the acidity of the reagent solution with 4 M HCl (prior to reduction of As 5+ to As 3+ ), which minimized interferences from dimethylarsinic acid. An inter-laboratory method validation was conducted among 12 laboratories worldwide in the analysis of six shared blind duplicates and a NIST Standard Reference Material involving different types of rice and iAs levels. Also, four laboratories used the standard HPLC-ICP-MS method to analyze the samples. The results between the methods were not significantly different, and the Horwitz ratio averaged 0.52 for the new method, which meets official method validation criteria. Thus, the simpler, more versatile, and less expensive method may be used by laboratories for several purposes to accurately determine iAs in rice grain. Graphical abstract Comparison of iAs results from new and FDA methods.

  19. Dissecting and Culturing Animal Cap Explants.

    PubMed

    Dingwell, Kevin S; Smith, James C

    2018-05-16

    The animal cap explant is a simple but adaptable tool available to developmental biologists. The use of animal cap explants in demonstrating the presence of mesoderm-inducting activity in the Xenopus embryo vegetal pole is one of many elegant examples of their worth. Animal caps respond to a range of growth factors (e.g., Wnts, FGF, TGF-β), making them especially useful for studying signal transduction pathways and gene regulatory networks. Explants are also suitable for examining cell behavior and have provided key insights into the molecular mechanisms controlling vertebrate morphogenesis. In this protocol, we outline two methods to isolate animal cap explants from Xenopus laevis , both of which can be applied easily to Xenopus tropicalis The first method is a standard manual method that can be used in any laboratory equipped with a standard dissecting microscope. For labs planning on dissecting large numbers of explants on a regular basis, a second, high throughput method is described that uses a specialized microcautery surgical instrument. © 2018 Cold Spring Harbor Laboratory Press.

  20. Food adulteration analysis without laboratory prepared or determined reference food adulterant values.

    PubMed

    Kalivas, John H; Georgiou, Constantinos A; Moira, Marianna; Tsafaras, Ilias; Petrakis, Eleftherios A; Mousdis, George A

    2014-04-01

    Quantitative analysis of food adulterants is an important health and economic issue that needs to be fast and simple. Spectroscopy has significantly reduced analysis time. However, still needed are preparations of analyte calibration samples matrix matched to prediction samples which can be laborious and costly. Reported in this paper is the application of a newly developed pure component Tikhonov regularization (PCTR) process that does not require laboratory prepared or reference analysis methods, and hence, is a greener calibration method. The PCTR method requires an analyte pure component spectrum and non-analyte spectra. As a food analysis example, synchronous fluorescence spectra of extra virgin olive oil samples adulterated with sunflower oil is used. Results are shown to be better than those obtained using ridge regression with reference calibration samples. The flexibility of PCTR allows including reference samples and is generic for use with other instrumental methods and food products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Standardization of fixation, processing and staining methods for the central nervous system of vertebrates.

    PubMed

    Aldana Marcos, H J; Ferrari, C C; Benitez, I; Affanni, J M

    1996-12-01

    This paper reports the standardization of methods used for processing and embedding various vertebrate brains of different size in paraffin. Other technical details developed for avoiding frequent difficulties arising during laboratory routine are also reported. Some modifications of the Nissl and Klüver-Barrera staining methods are proposed. These modifications include: 1) a Nissl stain solution with a rapid and efficient action with easier differentiation; 2) the use of a cheap microwave oven for the Klüver-Barrera stain. These procedures have the advantage of permitting Nissl and Klüver-Barrera staining of nervous tissue in about five and fifteen minutes respectively. The proposed procedures have been tested in brains obtained from fish, amphibians, reptiles and mammals of different body sizes. They are the result of our long experience in preparing slides for comparative studies. Serial sections of excellent quality were regularly obtained in all the specimens studied. These standardized methods, being simple and quick, are recommended for routine use in neurobiological laboratories.

  2. Simple optical method of qualitative assessment of sperm motility: preliminary results

    NASA Astrophysics Data System (ADS)

    Sozanska, Agnieszka; Kolwas, Krystyna; Galas, Jacek; Blocki, Narcyz; Czyzewski, Adam

    2005-09-01

    The examination of quality of the sperm ejaculate is one of the most important steps in artificial fertilization procedure. The main aim of semen storage centres is to characterise the best semen quality for fertilization. Reliable information about sperm motility is also one the most important parameters for in vitro laboratory procedures. There exist very expensive automated methods for semen analysis but they are unachievable for most of laboratories and semen storage centres. Motivation for this study is to elaborate a simple, cheap, objective and repeatable method for semen motility assessment. The method enables to detect even small changes in motility introduced by medical, physical or chemical factors. To test the reliability of the method we used cryopreserved bull semen from Lowicz Semen Storage Centre. The examined sperm specimen was warmed in water bath and then centrifuged. The best semen was collected by the swim-up technique and diluted to a proper concentration. Several semen concentrations and dilutions were tested in order to find the best probe parameters giving repeatable results. For semen visualization we used the phase-contrast microscope with a CCD camera. A PC computer was used to acquire and to analyse the data. The microscope table equipped with a microscope glass pool 0.7mm deep instead of some conventional plane microscope slides was stabilised at the temperature of 37°C. The main idea of our method is based on a numerical processing of the optical contrast of the sperm images which illustrates the dynamics of the sperm cells movement and on appropriate analysis of a grey scale level of the superimposed images. An elaborated numerical algorithm allows us to find the relative amount of motile sperm cells. The proposed method of sperm motility assessment seems to be objective and repeatable.

  3. Dental laboratory technology education in China: current situation and challenges.

    PubMed

    Zheng, Liwei; Yue, Li; Zhou, Min; Yu, Haiyang

    2013-03-01

    Modern dentistry and dental education in China were first introduced from abroad by Dr. Lindsay in 1907. However, advancements in the field of dental laboratory technology did not occur to the same degree in specialties such as prosthodontics and orthodontics. Since the 1990s, orders from abroad demanding dental appliances surged as the image of China as the "world's factory" strengthened. The assembly line model, in which technicians work like simple procedure workers, was rapidly applied to denture production, while the traditional education system and apprenticeship systems demonstrated little progress in these years. The lack of advancement in dental laboratory technology education caused insufficient development in China's dental technology industry. In order to alter the situation, a four-year dental laboratory technology undergraduate educational program was established in 2005 by West China School of Stomatology, Sichuan University (WCSS, SCU). This program was based on SCU's undergraduate education and WCSS's junior college education systems. The program introduced scientific methods in relevant subjects into laboratory technicians' training and made many improvements in the availability of trained faculty, textbooks, laboratory facilities, and curriculum.

  4. An outbreak of penicillin resistant Streptococcus pneumoniae investigated by a polymerase chain reaction based genotyping method.

    PubMed Central

    Gillespie, S H; McHugh, T D; Hughes, J E; Dickens, A; Kyi, M S; Kelsey, M

    1997-01-01

    AIMS: To characterise the genotypes of penicillin resistant Streptococcus pneumoniae infecting patients in a care of the elderly ward and to study its transmission in a hospital environment. METHODS: Isolates of S pneumoniae were cultured from specimens obtained from patients who had been admitted to a care of the elderly ward where an outbreak had occurred. Penicillin resistant S pneumoniae were also obtained from a series of surveillance throat swabs taken from patients in the same ward. In addition, all penicillin resistant S pneumoniae isolated from specimens submitted for culture at the time of the outbreak were included. Four sensitive strains isolated from a routine microbiology laboratory were included as controls. A simple polymerase chain reaction (PCR) based genotyping method for the penicillin binding protein (PBP) genes 1a, 2x, and 2b was used to characterise the genotypes. RESULTS: Nine patients were infected with serotype 9 S pneumoniae. Four of these patients died; two deaths were directly attributable to the infection. Tested against a battery of haemolytic streptococci and other organisms found in the respiratory tract, only two false positive reactions for PBP 2x were found among S mitis. The method demonstrated that the outbreak strain had altered PBP 1a, 2b, and 2x genes, a pattern clearly distinguishable from other penicillin resistant strains isolated at the same time. CONCLUSIONS: This method is simple to perform and would enable many laboratories to characterise the genotype of penicillin resistant S pneumoniae and investigate transmission in their hospitals. Images PMID:9462268

  5. The Effect of Combining Analogy-Based Simulation and Laboratory Activities on Turkish Elementary School Students' Understanding of Simple Electric Circuits

    ERIC Educational Resources Information Center

    Unlu, Zeynep Koyunlu; Dokme, Ibilge

    2011-01-01

    The purpose of this study was to investigate whether the combination of both analogy-based simulation and laboratory activities as a teaching tool was more effective than utilizing them separately in teaching the concepts of simple electricity. The quasi-experimental design that involved 66 seventh grade students from urban Turkish elementary…

  6. A Simple System for Observing Dynamic Phase Equilibrium via an Inquiry-Based Laboratory or Demonstration

    ERIC Educational Resources Information Center

    Cloonan, Carrie A.; Andrew, Julie A.; Nichol, Carolyn A.; Hutchinson, John S.

    2011-01-01

    This article describes an activity that can be used as an inquiry-based laboratory or demonstration for either high school or undergraduate chemistry students to provide a basis for understanding both vapor pressure and the concept of dynamic phase equilibrium. The activity includes a simple setup to create a closed system of only water liquid and…

  7. Introduction of a Simple Experiment for the Undergraduate Organic Chemistry Laboratory Demonstrating the Lewis Acid and Shape-Selective Properties of Zeolite Na-Y

    ERIC Educational Resources Information Center

    Maloney, Vincent; Szczepanski, Zach

    2017-01-01

    A simple, inexpensive, discovery-based experiment for undergraduate organic laboratories has been developed that demonstrates the Lewis acid and shape-selective properties of zeolites. Calcined zeolite Na-Y promotes the electrophilic aromatic bromination of toluene with a significantly higher para/ortho ratio than observed under conventional…

  8. SHERLOCK: Simple Human Experiments Regarding Locally Observed Collective Knowledge

    DTIC Science & Technology

    2015-12-01

    ARL-RP-0560 ● DEC 2015 US Army Research Laboratory SHERLOCK: Simple Human Experiments Regarding Locally Observed Collective...report when it is no longer needed. Do not return it to the originator. ARL-RP-0560 ● DEC 2015 US Army Research Laboratory SHERLOCK... Research and Engineering Directorate, ARL Reprinted from the International Technology Alliance Collaboration System [accessed 2015 Dec 2]. https

  9. Interlaboratory comparison of autoradiographic DNA profiling measurements: precision and concordance.

    PubMed

    Duewer, D L; Lalonde, S A; Aubin, R A; Fourney, R M; Reeder, D J

    1998-05-01

    Knowledge of the expected uncertainty in restriction fragment length polymorphism (RFLP) measurements is required for confident exchange of such data among different laboratories. The total measurement uncertainty among all Technical Working Group for DNA Analysis Methods laboratories has previously been characterized and found to be acceptably small. Casework cell line control measurements provided by six Royal Canadian Mounted Police (RCMP) and 30 U.S. commercial, local, state, and Federal forensic laboratories enable quantitative determination of the within-laboratory precision and among-laboratory concordance components of measurement uncertainty typical of both sets of laboratories. Measurement precision is the same in the two countries for DNA fragments of size 1000 base pairs (bp) to 10,000 bp. However, the measurement concordance among the RCMP laboratories is clearly superior to that within the U.S. forensic community. This result is attributable to the use of a single analytical protocol in all RCMP laboratories. Concordance among U.S. laboratories cannot be improved through simple mathematical adjustments. Community-wide efforts focused on improved concordance may be the most efficient mechanism for further reduction of among-laboratory RFLP measurement uncertainty, should the resources required to fully evaluate potential cross-jurisdictional matches become burdensome as the number of RFLP profiles on record increases.

  10. Pyocin-sensitivity testing as a method of typing Pseudomonas aeruginosa: use of "phage-free" preparations of pyocin.

    PubMed

    Rampling, A; Whitby, J L; Wildy, P

    1975-11-01

    A method for pyocin-sensitivity typing by means of "phage-free" preparations of pyocin is described. The method was tested on 227 isolates of P. aeruginosa, collected from 34 different foci of infection in hospitals in the British Isles and the results were compared with those for combined serological and phage typing of all strains and pyocin production of 105 of the isolates. It is concluded that pyocin-sensitivity typing is a simple and reliable method giving a high degree of discrimination, comparable to that of combined serological and phage typing, and it is suitable for use in routine hospital laboratories.

  11. A simple, low-cost, data logging pendulum built from a computer mouse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gintautas, Vadas; Hubler, Alfred

    Lessons and homework problems involving a pendulum are often a big part of introductory physics classes and laboratory courses from high school to undergraduate levels. Although laboratory equipment for pendulum experiments is commercially available, it is often expensive and may not be affordable for teachers on fixed budgets, particularly in developing countries. We present a low-cost, easy-to-build rotary sensor pendulum using the existing hardware in a ball-type computer mouse. We demonstrate how this apparatus may be used to measure both the frequency and coefficient of damping of a simple physical pendulum. This easily constructed laboratory equipment makes it possible formore » all students to have hands-on experience with one of the most important simple physical systems.« less

  12. Scale-Up of GRCop: From Laboratory to Rocket Engines

    NASA Technical Reports Server (NTRS)

    Ellis, David L.

    2016-01-01

    GRCop is a high temperature, high thermal conductivity copper-based series of alloys designed primarily for use in regeneratively cooled rocket engine liners. It began with laboratory-level production of a few grams of ribbon produced by chill block melt spinning and has grown to commercial-scale production of large-scale rocket engine liners. Along the way, a variety of methods of consolidating and working the alloy were examined, a database of properties was developed and a variety of commercial and government applications were considered. This talk will briefly address the basic material properties used for selection of compositions to scale up, the methods used to go from simple ribbon to rocket engines, the need to develop a suitable database, and the issues related to getting the alloy into a rocket engine or other application.

  13. Inactivation of stable viruses in cell culture facilities by peracetic acid fogging.

    PubMed

    Gregersen, Jens-Peter; Roth, Bernhard

    2012-07-01

    Looking for a robust and simple method to replace formaldehyde fumigation for the disinfection of virus-handling laboratories and facilities, we tested peracetic acid fogging as a method to inactivate stable viruses under practical conditions. Peracetic acid/hydrogen peroxide (5.8%/27.5%, 2.0 mL/m³) was diluted in sufficient water to achieve ≥ 70% relative humidity and was vaporized as <10 μm droplets in a fully equipped 95 m³ laboratory unit. High titers of reovirus 3, MVM parvovirus and an avian polyomavirus were coated on frosted glass carriers and were exposed to the peracetic acid fog in various positions in the laboratory. After vaporization, a 60 min exposure time, and venting of the laboratory, no residual virus was detected on any of the carriers (detection limit <1 infectious unit/sample volume tested). The log reduction values were 9.0 for reovirus, 6.4 for MVM parvovirus, and 7.65 for the polyomavirus. After more than 10 disinfection runs within 12 months, no damage or functional impairment of electrical and electronic equipment was noted. Copyright © 2012 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  14. Diazo processing of LANDSAT imagery: A low-cost instructional technique

    NASA Technical Reports Server (NTRS)

    Lusch, D. P.

    1981-01-01

    Diazo processing of LANDSAT imagery is a relatively simple and cost effective method of producing enhanced renditions of the visual LANDSAT products. This technique is capable of producing a variety of image enhancements which have value in a teaching laboratory environment. Additionally, with the appropriate equipment, applications research which relys on accurate and repeatable results is possible. Exposure and development equipment options, diazo materials, and enhancement routines are discussed.

  15. A simple method for the small scale synthesis and solid-phase extraction purification of steroid sulfates.

    PubMed

    Waller, Christopher C; McLeod, Malcolm D

    2014-12-01

    Steroid sulfates are a major class of steroid metabolite that are of growing importance in fields such as anti-doping analysis, the detection of residues in agricultural produce or medicine. Despite this, many steroid sulfate reference materials may have limited or no availability hampering the development of analytical methods. We report simple protocols for the rapid synthesis and purification of steroid sulfates that are suitable for adoption by analytical laboratories. Central to this approach is the use of solid-phase extraction (SPE) for purification, a technique routinely used for sample preparation in analytical laboratories around the world. The sulfate conjugates of sixteen steroid compounds encompassing a wide range of steroid substitution patterns and configurations are prepared, including the previously unreported sulfate conjugates of the designer steroids furazadrol (17β-hydroxyandrostan[2,3-d]isoxazole), isofurazadrol (17β-hydroxyandrostan[3,2-c]isoxazole) and trenazone (17β-hydroxyestra-4,9-dien-3-one). Structural characterization data, together with NMR and mass spectra are reported for all steroid sulfates, often for the first time. The scope of this approach for small scale synthesis is highlighted by the sulfation of 1μg of testosterone (17β-hydroxyandrost-4-en-3-one) as monitored by liquid chromatography-mass spectrometry (LCMS). Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Use of Collapsible Box Trainer as a Module for Resident Education

    PubMed Central

    Caban, Angel M.; Guido, Christopher; Silver, Michele; Rossidis, George; Sarosi, George

    2013-01-01

    Background and Objectives: We sought to determine whether training with a simple collapsible mobile box trainer leads to improved performance of fundamental laparoscopic skills (FLSs) during a 6-month interval versus validated laparoscopic box trainers and virtual-reality trainers, only accessible at a simulation training center. Methods: With institutional review board approval, 20 first- and second-year general surgery residents were randomized to scheduled training sessions in a surgical simulation laboratory or training in the use of a portable, collapsible Train Anywhere Skill Kit (TASKit) (Ethicon Endo-Surgery Cincinnati, OH, USA) trainer. Training was geared toward the FLS set for a skill assessment examination at a 6-month interval. Results: The residents who trained with the TASKit performed the peg-transfer, pattern-cut exercise, Endoloop, and intracorporeal knot-tying FLS tasks statistically more efficiently during their 6-month assessment versus their initial evaluation as compared with the group randomized to the simulation laboratory training. Conclusions: Using a simple collapsible mobile box trainer such as the TASKit can be a cost-effective method of training and preparing residents for FLS tasks considering the current cost associated with virtual and high-definition surgical trainers. This mode of surgical training allows residents to practice in their own time by removing barriers associated with simulation centers. PMID:24018083

  17. Foucault's method for measuring the speed of light with modern apparatus

    NASA Astrophysics Data System (ADS)

    Vörös, Zoltán; Weihs, Gregor

    2015-05-01

    In this paper, we introduce two simple and inexpensive, yet quite accurate versions of the well-known Foucault method for measuring the speed of light. In a compact footprint of just 20 cm by 270 cm with readily available laboratory items, a rotating mirror taken from a laser printer, and a webcam, we obtained c=296\\720+/- 3000 km s-1, and c=302\\295+/- 3000 km s-1, respectively, both within less than a per cent of the defined value. The experiment also prepares students for extracting data through image processing.

  18. Nanocrystal synthesis in microfluidic reactors: where next?

    PubMed

    Phillips, Thomas W; Lignos, Ioannis G; Maceiczyk, Richard M; deMello, Andrew J; deMello, John C

    2014-09-07

    The past decade has seen a steady rise in the use of microfluidic reactors for nanocrystal synthesis, with numerous studies reporting improved reaction control relative to conventional batch chemistry. However, flow synthesis procedures continue to lag behind batch methods in terms of chemical sophistication and the range of accessible materials, with most reports having involved simple one- or two-step chemical procedures directly adapted from proven batch protocols. Here we examine the current status of microscale methods for nanocrystal synthesis, and consider what role microreactors might ultimately play in laboratory-scale research and industrial production.

  19. A new modelling approach for zooplankton behaviour

    NASA Astrophysics Data System (ADS)

    Keiyu, A. Y.; Yamazaki, H.; Strickler, J. R.

    We have developed a new simulation technique to model zooplankton behaviour. The approach utilizes neither the conventional artificial intelligence nor neural network methods. We have designed an adaptive behaviour network, which is similar to BEER [(1990) Intelligence as an adaptive behaviour: an experiment in computational neuroethology, Academic Press], based on observational studies of zooplankton behaviour. The proposed method is compared with non- "intelligent" models—random walk and correlated walk models—as well as observed behaviour in a laboratory tank. Although the network is simple, the model exhibits rich behavioural patterns similar to live copepods.

  20. A Simple Laboratory Class Using a "Pseudomonas aeruginosa" Auxotroph to Illustrate UV-Mutagenic Killing, DNA Photorepair and Mutagenic DNA Repair

    ERIC Educational Resources Information Center

    Sobrero, Patricio; Valverde, Claudio

    2013-01-01

    A simple and cheap laboratory class is proposed to illustrate the lethal effect of UV radiation on bacteria and the operation of different DNA repair mechanisms. The class is divided into two sessions, an initial 3-hour experimental session and a second 2-hour analytical session. The experimental session involves two separate experiments: one…

  1. Validating the Goldstein-Wehner Law for the Stratified Positive Column of DC Discharge in an Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Lisovskiy, V. A.; Koval, V. A.; Artushenko, E. P.; Yegorenkov, V. D.

    2012-01-01

    In this paper we suggest a simple technique for validating the Goldstein-Wehner law for a stratified positive column of dc glow discharge while studying the properties of gas discharges in an undergraduate laboratory. To accomplish this a simple device with a pre-vacuum mechanical pump, dc source and gas pressure gauge is required. Experiments may…

  2. Bonding to oxide ceramics—laboratory testing versus clinical outcome.

    PubMed

    Kern, Matthias

    2015-01-01

    Despite a huge number of published laboratory bonding studies on dental oxide ceramics clinical long-term studies on resin bonded oxide ceramic restorations are rare. The purpose of this review is to present the best available clinical evidence for successful bonding of dental oxide ceramic restorations. Clinical trials with resin-bonded restorations that had no or only limited mechanical retention and were made from alumina or zirconia ceramic were identified using an electronic search in PubMed database. Overall 10 publications with clinical trials could be identified. Their clinical outcome was compared with that laboratory bond strength studies. Clinical data provide strong evidence that air-abrasion at a moderate pressure in combination with using phosphate monomer containing primers and/or luting resins provide long-term durable bonding to glass-infiltrated alumina and zirconia ceramic under the humid and stressful oral conditions. As simple and clinically reliable bonding methods to oxide ceramics exist, the rationale for development of alternative bonding methods might be reconsidered especially when these methods are more time consuming or require rather complicated and/or technique sensitive procedures. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. Development of a novel and simple method to evaluate disintegration of rapidly disintegrating tablets.

    PubMed

    Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi

    2013-01-01

    The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.

  4. Simple method for generating adjustable trains of picosecond electron bunches

    NASA Astrophysics Data System (ADS)

    Muggli, P.; Allen, B.; Yakimenko, V. E.; Park, J.; Babzien, M.; Kusche, K. P.; Kimura, W. D.

    2010-05-01

    A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.

  5. Tracking of electrochemical impedance of batteries

    NASA Astrophysics Data System (ADS)

    Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.

    2016-04-01

    This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.

  6. Comparative study of six sequential spectrophotometric methods for quantification and separation of ribavirin, sofosbuvir and daclatasvir: An application on Laboratory prepared mixture, pharmaceutical preparations, spiked human urine, spiked human plasma, and dissolution test.

    PubMed

    Hassan, Wafaa S; Elmasry, Manal S; Elsayed, Heba M; Zidan, Dalia W

    2018-09-05

    In accordance with International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines, six novel, simple and precise sequential spectrophotometric methods were developed and validated for the simultaneous analysis of Ribavirin (RIB), Sofosbuvir (SOF), and Daclatasvir (DAC) in their mixture without prior separation steps. These drugs are described as co-administered for treatment of Hepatitis C virus (HCV). HCV is the cause of hepatitis C and some cancers such as liver cancer (hepatocellular carcinoma) and lymphomas in humans. These techniques consisted of several sequential steps using zero, ratio and/or derivative spectra. DAC was first determined through direct spectrophotometry at 313.7 nm without any interference of the other two drugs while RIB and SOF can be determined after ratio subtraction through five methods; Ratio difference spectrophotometric method, successive derivative ratio method, constant center, isoabsorptive method at 238.8 nm, and mean centering of the ratio spectra (MCR) at 224 nm and 258 nm for RIB and SOF, respectively. The calibration curve is linear over the concentration ranges of (6-42), (10-70) and (4-16) μg/mL for RIB, SOF, and DAC, respectively. This method was successfully applied to commercial pharmaceutical preparation of the drugs, spiked human urine, and spiked human plasma. The above methods are very simple methods that were developed for the simultaneous determination of binary and ternary mixtures and so enhance signal-to-noise ratio. The method has been successfully applied to the simultaneous analysis of RIB, SOF, and DAC in laboratory prepared mixtures. The obtained results are statistically compared with those obtained by the official or reported methods, showing no significant difference with respect to accuracy and precision at p = 0.05. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Selected retinoids: determination by isocratic normal-phase HPLC.

    PubMed

    Klvanova, J; Brtko, J

    2002-09-01

    Retinol (ROL), retinal (RAL) and retinoic acid (RA) are physiologically active forms of vitamin A. All-trans retinoic acid (ATRA) can be formed by oxidation from all-trans retinal (ATRAL). Isomerization of RA is considered to be an important metabolic pathway of retinoids. RA isomers transactivate various response pathways via their cognate nuclear receptors that act as ligand inducible transcription factors. The aim of this study was to establish a rapid and simple method for determination of ATRA, 13-cis retinoic acid (13CRA) and ATRAL by HPLC. In our laboratory, we slightly modified the method of Miyagi et al. (2001) and separated ATRA, 13CRA and ATRAL by simple isocratic normal phase HPLC. Both retinoic acid isomers and ATRAL were eluted within 13 min and all components were well resolved. The coefficients of variation (C.V.) for RAs and RAL were from 3.0 to 5.4 %.

  8. [Microbiology--laboratory examinations for bacterias].

    PubMed

    Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi

    2002-11-01

    As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.

  9. Phase-and-amplitude recovery from a single phase-contrast image using partially spatially coherent x-ray radiation

    NASA Astrophysics Data System (ADS)

    Beltran, Mario A.; Paganin, David M.; Pelliccia, Daniele

    2018-05-01

    A simple method of phase-and-amplitude extraction is derived that corrects for image blurring induced by partially spatially coherent incident illumination using only a single intensity image as input. The method is based on Fresnel diffraction theory for the case of high Fresnel number, merged with the space-frequency description formalism used to quantify partially coherent fields and assumes the object under study is composed of a single-material. A priori knowledge of the object’s complex refractive index and information obtained by characterizing the spatial coherence of the source is required. The algorithm was applied to propagation-based phase-contrast data measured with a laboratory-based micro-focus x-ray source. The blurring due to the finite spatial extent of the source is embedded within the algorithm as a simple correction term to the so-called Paganin algorithm and is also numerically stable in the presence of noise.

  10. Using simple manipulatives to improve student comprehension of a complex biological process: protein synthesis.

    PubMed

    Guzman, Karen; Bartlett, John

    2012-01-01

    Biological systems and living processes involve a complex interplay of biochemicals and macromolecular structures that can be challenging for undergraduate students to comprehend and, thus, misconceptions abound. Protein synthesis, or translation, is an example of a biological process for which students often hold many misconceptions. This article describes an exercise that was developed to illustrate the process of translation using simple objects to represent complex molecules. Animations, 3D physical models, computer simulations, laboratory experiments and classroom lectures are also used to reinforce the students' understanding of translation, but by focusing on the simple manipulatives in this exercise, students are better able to visualize concepts that can elude them when using the other methods. The translation exercise is described along with suggestions for background material, questions used to evaluate student comprehension and tips for using the manipulatives to identify common misconceptions. Copyright © 2012 Wiley Periodicals, Inc.

  11. SERS-based pesticide detection by using nanofinger sensors

    NASA Astrophysics Data System (ADS)

    Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong

    2015-01-01

    Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.

  12. Identifying and quantifying interactions in a laboratory swarm

    NASA Astrophysics Data System (ADS)

    Puckett, James; Kelley, Douglas; Ouellette, Nicholas

    2013-03-01

    Emergent collective behavior, such as in flocks of birds or swarms of bees, is exhibited throughout the animal kingdom. Many models have been developed to describe swarming and flocking behavior using systems of self-propelled particles obeying simple rules or interacting via various potentials. However, due to experimental difficulties and constraints, little empirical data exists for characterizing the exact form of the biological interactions. We study laboratory swarms of flying Chironomus riparius midges, using stereoimaging and particle tracking techniques to record three-dimensional trajectories for all the individuals in the swarm. We describe methods to identify and quantify interactions by examining these trajectories, and report results on interaction magnitude, frequency, and mutuality.

  13. Laboratory Activity on Sample Handling and Maintaining a Laboratory Notebook through Simple pH Measurements

    ERIC Educational Resources Information Center

    Erdmann, Mitzy A.; March, Joe L.

    2016-01-01

    Sample handling and laboratory notebook maintenance are necessary skills but can seem abstract if not presented to students in context. An introductory exercise focusing on proper sample handling, data collection and laboratory notebook keeping for the general chemistry laboratory was developed to emphasize the importance of keeping an accurate…

  14. [Development of molecular detection of food-borne pathogenic bacteria using miniaturized microfluidic devices].

    PubMed

    Iván, Kristóf; Maráz, Anna

    2015-12-20

    Detection and identification of food-borne pathogenic bacteria are key points for the assurance of microbiological food safety. Traditional culture-based methods are more and more replaced by or supplemented with nucleic acid based molecular techniques, targeting specific (preferably virulence) genes in the genomes. Internationally validated DNA amplification - most frequently real-time polymerase chain reaction - methods are applied by the food microbiological testing laboratories for routine analysis, which will result not only in shortening the time for results but they also improve the performance characteristics (e.g. sensitivity, specificity) of the methods. Beside numerous advantages of the polymerase chain reaction based techniques for routine microbiological analysis certain drawbacks have to be mentioned, such as the high cost of the equipment and reagents, as well as the risk of contamination of the laboratory environment by the polymerase chain reaction amplicons, which require construction of an isolated laboratory system. Lab-on-a-chip systems can integrate most of these laboratory processes within a miniaturized device that delivers the same specificity and reliability as the standard protocols. The benefits of miniaturized devices are: simple - often automated - use, small overall size, portability, sterility due to single use possibility. These miniaturized rapid diagnostic tests are being researched and developed at the best research centers around the globe implementing various sample preparation and molecular DNA amplification methods on-chip. In parallel, the aim of the authors' research is to develop microfluidic Lab-on-a-chip devices for the detection and identification of food-borne pathogenic bacteria.

  15. Quantification of histochemical stains using whole slide imaging: development of a method and demonstration of its usefulness in laboratory quality control.

    PubMed

    Gray, Allan; Wright, Alex; Jackson, Pete; Hale, Mike; Treanor, Darren

    2015-03-01

    Histochemical staining of tissue is a fundamental technique in tissue diagnosis and research, but it suffers from significant variability. Efforts to address this include laboratory quality controls and quality assurance schemes, but these rely on subjective interpretation of stain quality, are laborious and have low reproducibility. We aimed (1) to develop a method for histochemical stain quantification using whole slide imaging and image analysis and (2) to demonstrate its usefulness in measuring staining variation. A method to quantify the individual stain components of histochemical stains on virtual slides was developed. It was evaluated for repeatability and reproducibility, then applied to control sections of an appendix to quantify H&E staining (H/E intensities and H:E ratio) between automated staining machines and to measure differences between six regional diagnostic laboratories. The method was validated with <0.5% variation in H:E ratio measurement when using the same scanner for a batch of slides (ie, it was repeatable) but was not highly reproducible between scanners or over time, where variation of 7% was found. Application of the method showed H:E ratios between three staining machines varied from 0.69 to 0.93, H:E ratio variation over time was observed. Interlaboratory comparison demonstrated differences in H:E ratio between regional laboratories from 0.57 to 0.89. A simple method using whole slide imaging can be used to quantify and compare histochemical staining. This method could be deployed in routine quality assurance and quality control. Work is needed on whole slide imaging devices to improve reproducibility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. A Good Death? Report of the Second Newcastle Meeting on Laboratory Animal Euthanasia

    PubMed Central

    Hawkins, Penny; Prescott, Mark J.; Carbone, Larry; Dennison, Ngaire; Johnson, Craig; Makowska, I. Joanna; Marquardt, Nicole; Readman, Gareth; Weary, Daniel M.; Golledge, Huw D. R.

    2016-01-01

    Simple Summary Millions of laboratory animals are killed each year worldwide. However, there is a lack of consensus regarding what methods of killing are humane for many species and stages of development. This report summarises research findings and discussions from an international meeting of experts and stakeholders, with recommendations to inform good practice for humane killing of mice, rats and zebrafish. It provides additional guidance and perspectives for researchers designing projects that involve euthanasing animals, researchers studying aspects of humane killing, euthanasia device manufacturers, regulators, and institutional ethics or animal care and use committees that wish to review local practice. Abstract Millions of laboratory animals are killed each year worldwide. There is an ethical, and in many countries also a legal, imperative to ensure those deaths cause minimal suffering. However, there is a lack of consensus regarding what methods of killing are humane for many species and stages of development. In 2013, an international group of researchers and stakeholders met at Newcastle University, United Kingdom to discuss the latest research and which methods could currently be considered most humane for the most commonly used laboratory species (mice, rats and zebrafish). They also discussed factors to consider when making decisions about appropriate techniques for particular species and projects, and priorities for further research. This report summarises the research findings and discussions, with recommendations to help inform good practice for humane killing. PMID:27563926

  17. Simple non-laboratory- and laboratory-based risk assessment algorithms and nomogram for detecting undiagnosed diabetes mellitus.

    PubMed

    Wong, Carlos K H; Siu, Shing-Chung; Wan, Eric Y F; Jiao, Fang-Fang; Yu, Esther Y T; Fung, Colman S C; Wong, Ka-Wai; Leung, Angela Y M; Lam, Cindy L K

    2016-05-01

    The aim of the present study was to develop a simple nomogram that can be used to predict the risk of diabetes mellitus (DM) in the asymptomatic non-diabetic subjects based on non-laboratory- and laboratory-based risk algorithms. Anthropometric data, plasma fasting glucose, full lipid profile, exercise habits, and family history of DM were collected from Chinese non-diabetic subjects aged 18-70 years. Logistic regression analysis was performed on a random sample of 2518 subjects to construct non-laboratory- and laboratory-based risk assessment algorithms for detection of undiagnosed DM; both algorithms were validated on data of the remaining sample (n = 839). The Hosmer-Lemeshow test and area under the receiver operating characteristic (ROC) curve (AUC) were used to assess the calibration and discrimination of the DM risk algorithms. Of 3357 subjects recruited, 271 (8.1%) had undiagnosed DM defined by fasting glucose ≥7.0 mmol/L or 2-h post-load plasma glucose ≥11.1 mmol/L after an oral glucose tolerance test. The non-laboratory-based risk algorithm, with scores ranging from 0 to 33, included age, body mass index, family history of DM, regular exercise, and uncontrolled blood pressure; the laboratory-based risk algorithm, with scores ranging from 0 to 37, added triglyceride level to the risk factors. Both algorithms demonstrated acceptable calibration (Hosmer-Lemeshow test: P = 0.229 and P = 0.483) and discrimination (AUC 0.709 and 0.711) for detection of undiagnosed DM. A simple-to-use nomogram for detecting undiagnosed DM has been developed using validated non-laboratory-based and laboratory-based risk algorithms. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  18. Advanced yellow fever virus genome detection in point-of-care facilities and reference laboratories.

    PubMed

    Domingo, Cristina; Patel, Pranav; Yillah, Jasmin; Weidmann, Manfred; Méndez, Jairo A; Nakouné, Emmanuel Rivalyn; Niedrig, Matthias

    2012-12-01

    Reported methods for the detection of the yellow fever viral genome are beset by limitations in sensitivity, specificity, strain detection spectra, and suitability to laboratories with simple infrastructure in areas of endemicity. We describe the development of two different approaches affording sensitive and specific detection of the yellow fever genome: a real-time reverse transcription-quantitative PCR (RT-qPCR) and an isothermal protocol employing the same primer-probe set but based on helicase-dependent amplification technology (RT-tHDA). Both assays were evaluated using yellow fever cell culture supernatants as well as spiked and clinical samples. We demonstrate reliable detection by both assays of different strains of yellow fever virus with improved sensitivity and specificity. The RT-qPCR assay is a powerful tool for reference or diagnostic laboratories with real-time PCR capability, while the isothermal RT-tHDA assay represents a useful alternative to earlier amplification techniques for the molecular diagnosis of yellow fever by field or point-of-care laboratories.

  19. Detecting Seismic Events Using a Supervised Hidden Markov Model

    NASA Astrophysics Data System (ADS)

    Burks, L.; Forrest, R.; Ray, J.; Young, C.

    2017-12-01

    We explore the use of supervised hidden Markov models (HMMs) to detect seismic events in streaming seismogram data. Current methods for seismic event detection include simple triggering algorithms, such as STA/LTA and the Z-statistic, which can lead to large numbers of false positives that must be investigated by an analyst. The hypothesis of this study is that more advanced detection methods, such as HMMs, may decreases false positives while maintaining accuracy similar to current methods. We train a binary HMM classifier using 2 weeks of 3-component waveform data from the International Monitoring System (IMS) that was carefully reviewed by an expert analyst to pick all seismic events. Using an ensemble of simple and discrete features, such as the triggering of STA/LTA, the HMM predicts the time at which transition occurs from noise to signal. Compared to the STA/LTA detection algorithm, the HMM detects more true events, but the false positive rate remains unacceptably high. Future work to potentially decrease the false positive rate may include using continuous features, a Gaussian HMM, and multi-class HMMs to distinguish between types of seismic waves (e.g., P-waves and S-waves). Acknowledgement: Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.SAND No: SAND2017-8154 A

  20. A quick and simple method, usable in the field, for collecting parasites in suitable condition for both morphological and molecular studies.

    PubMed

    Justine, Jean-Lou; Briand, Marine J; Bray, Rodney A

    2012-07-01

    Many methods have been proposed for collecting and fixing parasites, but most were written before the molecular age, and were intended to be practised by experienced parasitologists in well-equipped laboratories. We describe here a very simple method, illustrated by photographs, for collecting helminths from the digestive tract of vertebrates. It only requires a few plastic vials, some ethanol and a means to heat water. Basically, the method consists of: (a) the extraction of all organs from the abdominal cavity; (b) opening the digestive system longitudinally; (c) agitate gut and contents in a saline solution (i.e. ca. 9% NaCl or 1/4 sea water in tap water); (d) decant in saline as many times as needed to clean contents; (e) immediately fix parasites in near-boiling saline; (f) discard saline and keep specimens in 95% ethanol. Additional information is given for collecting parasites from fish gills with a similar process. The method will collect most helminths (digeneans, larval cestodes, nematodes, acanthocephalans) from the digestive tract, and monogeneans and isopod and copepod crustaceans from fish gills. The specimens will be suitable for both morphological study and DNA sequencing. The method is simple, fast, inexpensive and can be used by untrained personnel, even in the field without electricity and without a binocular microscope. It can also be used by trained parasitologists who need to expedite treatment of abundant samples.

  1. Simple procedures to obtain exogenous internal controls for use in RT-PCR detection of bovine pestiviruses.

    PubMed

    Golemba, Marcelo D; Parreño, Viviana; Jones, Leandro R

    2008-06-01

    Pestiviruses are ubiquitous pathogens of cattle and frequent adventitious viruses in biologicals. Furthermore, it has been suggested that these agents might be related to infantile gastroenteritis and microencephaly. Since the virus is highly prevalent in fetal bovine serum, the risk of contamination is high in most laboratories. Thus, the implementation of detection methods in all laboratories is of worth. Despite continuous surveillance, these agents have been detected in cell lines, fetal bovine serum, live and inactivated animal and human vaccines and interferon for human use. In this report, DNA and RNA internal controls (ICs) which can be implemented in laboratories with minimal equipment are described. The developed standards can be added before RNA purification, allowing to monitor all steps of the protocol (viral RNA extraction, reverse transcription and cDNA amplification). It is shown that inhibitory effects that could lead to decreased sensitivity can be minimized by controlling the amount of mimic molecules added to the samples. A method to avoid the problem of DNA traces present in in vitro transcribed RNA preparations is provided.

  2. Timeliness “at a glance”: assessing the turnaround time through the six sigma metrics.

    PubMed

    Ialongo, Cristiano; Bernardini, Sergio

    2016-01-01

    Almost thirty years of systematic analysis have proven the turnaround time to be a fundamental dimension for the clinical laboratory. Several indicators are to date available to assess and report quality with respect to timeliness, but they sometimes lack the communicative immediacy and accuracy. The six sigma is a paradigm developed within the industrial domain for assessing quality and addressing goal and issues. The sigma level computed through the Z-score method is a simple and straightforward tool which delivers quality by a universal dimensionless scale and allows to handle non-normal data. Herein we report our preliminary experience in using the sigma level to assess the change in urgent (STAT) test turnaround time due to the implementation of total automation. We found that the Z-score method is a valuable and easy to use method for assessing and communicating the quality level of laboratory timeliness, providing a good correspondence with the actual change in efficiency which was retrospectively observed.

  3. Mammalian Cell Encapsulation in Alginate Beads Using a Simple Stirred Vessel.

    PubMed

    Hoesli, Corinne A; Kiang, Roger L J; Raghuram, Kamini; Pedroza, René G; Markwick, Karen E; Colantuoni, Antonio M R; Piret, James M

    2017-06-29

    Cell encapsulation in alginate beads has been used for immobilized cell culture in vitro as well as for immunoisolation in vivo. Pancreatic islet encapsulation has been studied extensively as a means to increase islet survival in allogeneic or xenogeneic transplants. Alginate encapsulation is commonly achieved by nozzle extrusion and external gelation. Using this method, cell-containing alginate droplets formed at the tip of nozzles fall into a solution containing divalent cations that cause ionotropic alginate gelation as they diffuse into the droplets. The requirement for droplet formation at the nozzle tip limits the volumetric throughput and alginate concentration that can be achieved. This video describes a scalable emulsification method to encapsulate mammalian cells in 0.5% to 10% alginate with 70% to 90% cell survival. By this alternative method, alginate droplets containing cells and calcium carbonate are emulsified in mineral oil, followed by a decrease in pH leading to internal calcium release and ionotropic alginate gelation. The current method allows the production of alginate beads within 20 min of emulsification. The equipment required for the encapsulation step consists in simple stirred vessels available to most laboratories.

  4. Mean centering of ratio spectra and concentration augmented classical least squares in a comparative approach for quantitation of spectrally overlapped bands of antihypertensives in formulations

    NASA Astrophysics Data System (ADS)

    Hegazy, Maha Abdel Monem; Fayez, Yasmin Mohammed

    2015-04-01

    Two different methods manipulating spectrophotometric data have been developed, validated and compared. One is capable of removing the signal of any interfering components at the selected wavelength of the component of interest (univariate). The other includes more variables and extracts maximum information to determine the component of interest in the presence of other components (multivariate). The applied methods are smart, simple, accurate, sensitive, precise and capable of determination of spectrally overlapped antihypertensives; hydrochlorothiazide (HCT), irbesartan (IRB) and candesartan (CAN). Mean centering of ratio spectra (MCR) and concentration residual augmented classical least-squares method (CRACLS) were developed and their efficiency was compared. CRACLS is a simple method that is capable of extracting the pure spectral profiles of each component in a mixture. Correlation was calculated between the estimated and pure spectra and was found to be 0.9998, 0.9987 and 0.9992 for HCT, IRB and CAN, respectively. The methods were successfully determined the three components in bulk powder, laboratory-prepared mixtures, and combined dosage forms. The results obtained were compared statistically with each other and to those of the official methods.

  5. A Simple and Sensitive Plant-Based Western Corn Rootworm Bioassay Method for Resistance Determination and Event Selection.

    PubMed

    Wen, Zhimou; Chen, Jeng Shong

    2018-05-26

    We report here a simple and sensitive plant-based western corn rootworm, Diabrotica virgifera virgifera LeConte (Coleoptera: Chrysomelidae), bioassay method that allows for examination of multiple parameters for both plants and insects in a single experimental setup within a short duration. For plants, injury to roots can be visually examined, fresh root weight can be measured, and expression of trait protein in plant roots can be analyzed. For insects, in addition to survival, larval growth and development can be evaluated in several aspects including body weight gain, body length, and head capsule width. We demonstrated using the method that eCry3.1Ab-expressing 5307 corn was very effective against western corn rootworm by eliciting high mortality and significantly inhibiting larval growth and development. We also validated that the method allowed determination of resistance in an eCry3.1Ab-resistant western corn rootworm strain. While data presented in this paper demonstrate the usefulness of the method for selection of events of protein traits and for determination of resistance in laboratory populations, we envision that the method can be applied in much broader applications.

  6. Evaluation of Two Lyophilized Molecular Assays to Rapidly Detect Foot-and-Mouth Disease Virus Directly from Clinical Samples in Field Settings.

    PubMed

    Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L

    2017-06-01

    Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  7. Evolutionary Influenced Interaction Pattern as Indicator for the Investigation of Natural Variants Causing Nephrogenic Diabetes Insipidus

    PubMed Central

    Labudde, Dirk

    2015-01-01

    The importance of short membrane sequence motifs has been shown in many works and emphasizes the related sequence motif analysis. Together with specific transmembrane helix-helix interactions, the analysis of interacting sequence parts is helpful for understanding the process during membrane protein folding and in retaining the three-dimensional fold. Here we present a simple high-throughput analysis method for deriving mutational information of interacting sequence parts. Applied on aquaporin water channel proteins, our approach supports the analysis of mutational variants within different interacting subsequences and finally the investigation of natural variants which cause diseases like, for example, nephrogenic diabetes insipidus. In this work we demonstrate a simple method for massive membrane protein data analysis. As shown, the presented in silico analyses provide information about interacting sequence parts which are constrained by protein evolution. We present a simple graphical visualization medium for the representation of evolutionary influenced interaction pattern pairs (EIPPs) adapted to mutagen investigations of aquaporin-2, a protein whose mutants are involved in the rare endocrine disorder known as nephrogenic diabetes insipidus, and membrane proteins in general. Furthermore, we present a new method to derive new evolutionary variations within EIPPs which can be used for further mutagen laboratory investigations. PMID:26180540

  8. Evolutionary Influenced Interaction Pattern as Indicator for the Investigation of Natural Variants Causing Nephrogenic Diabetes Insipidus.

    PubMed

    Grunert, Steffen; Labudde, Dirk

    2015-01-01

    The importance of short membrane sequence motifs has been shown in many works and emphasizes the related sequence motif analysis. Together with specific transmembrane helix-helix interactions, the analysis of interacting sequence parts is helpful for understanding the process during membrane protein folding and in retaining the three-dimensional fold. Here we present a simple high-throughput analysis method for deriving mutational information of interacting sequence parts. Applied on aquaporin water channel proteins, our approach supports the analysis of mutational variants within different interacting subsequences and finally the investigation of natural variants which cause diseases like, for example, nephrogenic diabetes insipidus. In this work we demonstrate a simple method for massive membrane protein data analysis. As shown, the presented in silico analyses provide information about interacting sequence parts which are constrained by protein evolution. We present a simple graphical visualization medium for the representation of evolutionary influenced interaction pattern pairs (EIPPs) adapted to mutagen investigations of aquaporin-2, a protein whose mutants are involved in the rare endocrine disorder known as nephrogenic diabetes insipidus, and membrane proteins in general. Furthermore, we present a new method to derive new evolutionary variations within EIPPs which can be used for further mutagen laboratory investigations.

  9. A Simple and Rapid Protocol for Producing Yeast Extract from Saccharomyces cerevisiae Suitable for Preparing Bacterial Culture Media

    PubMed Central

    Zarei, Omid; Dastmalchi, Siavoush; Hamzeh-Mivehroud, Maryam

    2016-01-01

    Yeasts, especially Saccharomyces cerevisiae, are one of the oldest organisms with broad spectrum of applications, owing to their unique genetics and physiology. Yeast extract, i.e. the product of yeast cells, is extensively used as nutritional resource in bacterial culture media. The aim of this study was to develop a simple, rapid and cost benefit process to produce the yeast extract. In this procedure mechanical methods such as high temperature and pressure were utilized to produce the yeast extract. The growth of the bacteria feed with the produced yeast extract was monitored in order to assess the quality of the product. The results showed that the quality of the produced yeast extract was very promising concluded from the growth pattern of bacterial cells in media prepared from this product and was comparable with that of the three commercial yeast extracts in terms of bacterial growth properties. One of the main advantages of the current method was that no chemicals and enzymes were used, leading to the reduced production cost. The method is very simple and cost effective, and can be performed in a reasonable time making it suitable for being adopted by research laboratories. Furthermore, it can be scaled up to produce large quantities for industrial applications. PMID:28243289

  10. Comparative assessment of absolute cardiovascular disease risk characterization from non-laboratory-based risk assessment in South African populations

    PubMed Central

    2013-01-01

    Background All rigorous primary cardiovascular disease (CVD) prevention guidelines recommend absolute CVD risk scores to identify high- and low-risk patients, but laboratory testing can be impractical in low- and middle-income countries. The purpose of this study was to compare the ranking performance of a simple, non-laboratory-based risk score to laboratory-based scores in various South African populations. Methods We calculated and compared 10-year CVD (or coronary heart disease (CHD)) risk for 14,772 adults from thirteen cross-sectional South African populations (data collected from 1987 to 2009). Risk characterization performance for the non-laboratory-based score was assessed by comparing rankings of risk with six laboratory-based scores (three versions of Framingham risk, SCORE for high- and low-risk countries, and CUORE) using Spearman rank correlation and percent of population equivalently characterized as ‘high’ or ‘low’ risk. Total 10-year non-laboratory-based risk of CVD death was also calculated for a representative cross-section from the 1998 South African Demographic Health Survey (DHS, n = 9,379) to estimate the national burden of CVD mortality risk. Results Spearman correlation coefficients for the non-laboratory-based score with the laboratory-based scores ranged from 0.88 to 0.986. Using conventional thresholds for CVD risk (10% to 20% 10-year CVD risk), 90% to 92% of men and 94% to 97% of women were equivalently characterized as ‘high’ or ‘low’ risk using the non-laboratory-based and Framingham (2008) CVD risk score. These results were robust across the six risk scores evaluated and the thirteen cross-sectional datasets, with few exceptions (lower agreement between the non-laboratory-based and Framingham (1991) CHD risk scores). Approximately 18% of adults in the DHS population were characterized as ‘high CVD risk’ (10-year CVD death risk >20%) using the non-laboratory-based score. Conclusions We found a high level of correlation between a simple, non-laboratory-based CVD risk score and commonly-used laboratory-based risk scores. The burden of CVD mortality risk was high for men and women in South Africa. The policy and clinical implications are that fast, low-cost screening tools can lead to similar risk assessment results compared to time- and resource-intensive approaches. Until setting-specific cohort studies can derive and validate country-specific risk scores, non-laboratory-based CVD risk assessment could be an effective and efficient primary CVD screening approach in South Africa. PMID:23880010

  11. Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peascoe, RA

    2001-09-25

    Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less

  12. Consequences of using different soil texture determination methodologies for soil physical quality and unsaturated zone time lag estimates

    NASA Astrophysics Data System (ADS)

    Fenton, O.; Vero, S.; Ibrahim, T. G.; Murphy, P. N. C.; Sherriff, S. C.; Ó hUallacháin, D.

    2015-11-01

    Elucidation of when the loss of pollutants, below the rooting zone in agricultural landscapes, affects water quality is important when assessing the efficacy of mitigation measures. Investigation of this inherent time lag (tT) is divided into unsaturated (tu) and saturated (ts) components. The duration of these components relative to each other differs depending on soil characteristics and the landscape position. The present field study focuses on tu estimation in a scenario where the saturated zone is likely to constitute a higher proportion of tT. In such instances, or where only initial breakthrough (IBT) or centre of mass (COM) is of interest, utilisation of site and depth specific "simple" textural class or actual sand-silt-clay percentages to generate soil water characteristic curves with associated soil hydraulic parameters is acceptable. With the same data it is also possible to estimate a soil physical quality (S) parameter for each soil layer which can be used to infer many other physical, chemical and biological quality indicators. In this study, hand texturing in the field was used to determine textural classes of a soil profile. Laboratory methods, including hydrometer, pipette and laser diffraction methods were used to determine actual sand-silt-clay percentages of sections of the same soil profile. Results showed that in terms of S, hand texturing resulted in a lower index value (inferring a degraded soil) than that of pipette, hydrometer and laser equivalents. There was no difference between S index values determined using the pipette, hydrometer and laser diffraction methods. The difference between the three laboratory methods on both the IBT and COM stages of tu were negligible, and in this instance were unlikely to affect either groundwater monitoring decisions, or to be of consequence from a policy perspective. When tu estimates are made over the full depth of the vadose zone, which may extend to several metres, errors resulting from the use of hydraulic parameters generated from hand texture data will be resultantly greater, and may lead to flawed predictions regarding the achievability of water policy targets. For this reason laboratory analysis, regardless of method, should be preferred to simple field assessments.

  13. Engineered nanomaterials: toward effective safety management in research laboratories.

    PubMed

    Groso, Amela; Petri-Fink, Alke; Rothen-Rutishauser, Barbara; Hofmann, Heinrich; Meyer, Thierry

    2016-03-15

    It is still unknown which types of nanomaterials and associated doses represent an actual danger to humans and environment. Meanwhile, there is consensus on applying the precautionary principle to these novel materials until more information is available. To deal with the rapid evolution of research, including the fast turnover of collaborators, a user-friendly and easy-to-apply risk assessment tool offering adequate preventive and protective measures has to be provided. Based on new information concerning the hazards of engineered nanomaterials, we improved a previously developed risk assessment tool by following a simple scheme to gain in efficiency. In the first step, using a logical decision tree, one of the three hazard levels, from H1 to H3, is assigned to the nanomaterial. Using a combination of decision trees and matrices, the second step links the hazard with the emission and exposure potential to assign one of the three nanorisk levels (Nano 3 highest risk; Nano 1 lowest risk) to the activity. These operations are repeated at each process step, leading to the laboratory classification. The third step provides detailed preventive and protective measures for the determined level of nanorisk. We developed an adapted simple and intuitive method for nanomaterial risk management in research laboratories. It allows classifying the nanoactivities into three levels, additionally proposing concrete preventive and protective measures and associated actions. This method is a valuable tool for all the participants in nanomaterial safety. The users experience an essential learning opportunity and increase their safety awareness. Laboratory managers have a reliable tool to obtain an overview of the operations involving nanomaterials in their laboratories; this is essential, as they are responsible for the employee safety, but are sometimes unaware of the works performed. Bringing this risk to a three-band scale (like other types of risks such as biological, radiation, chemical, etc.) facilitates the management for occupational health and safety specialists. Institutes and school managers can obtain the necessary information to implement an adequate safety management system. Having an easy-to-use tool enables a dialog between all these partners, whose semantic and priorities in terms of safety are often different.

  14. Simultaneous determination of diaveridine, trimethoprim and ormetoprim in feed using high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Yang, Ya-Jun; Liu, Xi-Wang; Li, Bing; Li, Shi-Hong; Kong, Xiao-Jun; Qin, Zhe; Li, Jian-Yong

    2016-12-01

    This study developed and validated a simple and reliable method for detecting and quantifying DVD, TMP and OMP in feed using dichloromethane extraction followed by HPLC-MS/MS. A matrix effect evaluation was performed using the post-extraction spiking method, and levels were less than ±15% in all three feeds with their corresponding concentrations. LOD and LOQ, CCα and CCβ were 20μgkg(-1) and 40μgkg(-1), 8.68-15.55μgkg(-1) and 10.61-18.92μgkg(-1) for all analytes, respectively. Calibration curves were linear for DVD, TMP and OMP with R(2)⩾0.990 and r⩾0.995, respectively. Recoveries of low, medium and high concentrations using the proposed method ranged from 74.4 to 105.2%. Repeatability and within-laboratory reproducibility were <7.4% (RSD). The chosen seven factors had no a significant influence on robustness. The method showed good performance when it was applied to analyze other laboratory-prepared or actual feed samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Efficient production of a gene mutant cell line through integrating TALENs and high-throughput cell cloning.

    PubMed

    Sun, Changhong; Fan, Yu; Li, Juan; Wang, Gancheng; Zhang, Hanshuo; Xi, Jianzhong Jeff

    2015-02-01

    Transcription activator-like effectors (TALEs) are becoming powerful DNA-targeting tools in a variety of mammalian cells and model organisms. However, generating a stable cell line with specific gene mutations in a simple and rapid manner remains a challenging task. Here, we report a new method to efficiently produce monoclonal cells using integrated TALE nuclease technology and a series of high-throughput cell cloning approaches. Following this method, we obtained three mTOR mutant 293T cell lines within 2 months, which included one homozygous mutant line. © 2014 Society for Laboratory Automation and Screening.

  16. Simple Technique for Dark-Field Photography of Immunodiffusion Bands

    PubMed Central

    Jensh, Ronald P.; Brent, Robert L.

    1969-01-01

    A simple dark-field photographic technique was developed which enables laboratory personnel with minimal photographic training to easily record antigen-antibody patterns on immunodiffusion plates. Images PMID:4979944

  17. Rapid determination of fumonisins in corn-based products by liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Wei; Herrman, Timothy J; Dai, Susie Y

    2010-01-01

    A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.

  18. The electrum-tarnish method for the determination of the fugacity of sulfur in laboratory sulfide systems

    USGS Publications Warehouse

    Barton, P.B.; Toulmin, P.

    1964-01-01

    A new method for the determination of the fugacity of sulfur in laboratory systems consists of visual observation of the development and decomposition of a sulfide tarnish phase on silver-gold alloy (electrum) of precisely known composition. The alloy system is calibrated against pure sulfur. The method has the following advantages: simple apparatus; ability to cover a large range of fugacity of S2; ability to cover a large temperature range by permitting runs of long duration; ability to tolerate other components in the gas phase; and ease of recovery of the quenched charges for determinations of phases and compositions. Results obtained by the electrum-tarnish method are in satisfactory agreement with those obtained by other workers for the fs2 vs. T curves for the assemblage Ni(1-x)S + NiS2. The electrum-tarnish method shows promise for investigating many other reactions. Univariant reactions studied by this method can be represented as lines forming a genetic grid in terms of the environmental parameters fs2 and T, The slopes of such lines can yield valuable thermodynamic data for the phases involved, but activity coefficients must be known for phases of variable composition. ?? 1964.

  19. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing

    PubMed Central

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-01-01

    Aims A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R2), using R2 as the primary metric of assay agreement. However, the use of R2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. Methods We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Results Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. Conclusions The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. PMID:28747393

  20. Evaluation of a simple polytetrafluoroethylene (PTFE)-based membrane for blood-feeding of malaria and dengue fever vectors in the laboratory.

    PubMed

    Siria, Doreen J; Batista, Elis P A; Opiyo, Mercy A; Melo, Elizangela F; Sumaye, Robert D; Ngowo, Halfan S; Eiras, Alvaro E; Okumu, Fredros O

    2018-04-11

    Controlled blood-feeding is essential for maintaining laboratory colonies of disease-transmitting mosquitoes and investigating pathogen transmission. We evaluated a low-cost artificial feeding (AF) method, as an alternative to direct human feeding (DHF), commonly used in mosquito laboratories. We applied thinly-stretched pieces of polytetrafluoroethylene (PTFE) membranes cut from locally available seal tape (i.e. plumbers tape, commonly used for sealing pipe threads in gasworks or waterworks). Approximately 4 ml of bovine blood was placed on the bottom surfaces of inverted Styrofoam cups and then the PTFE membranes were thinly stretched over the surfaces. The cups were filled with boiled water to keep the blood warm (~37 °C), and held over netting cages containing 3-4 day-old inseminated adults of female Aedes aegypti, Anopheles gambiae (s.s.) or Anopheles arabiensis. Blood-feeding success, fecundity and survival of mosquitoes maintained by this system were compared against DHF. Aedes aegypti achieved 100% feeding success on both AF and DHF, and also similar fecundity rates (13.1 ± 1.7 and 12.8 ± 1.0 eggs/mosquito respectively; P > 0.05). An. arabiensis had slightly lower feeding success on AF (85.83 ± 16.28%) than DHF (98.83 ± 2.29%) though these were not statistically different (P > 0.05), and also comparable fecundity between AF (8.82 ± 7.02) and DHF (8.02 ± 5.81). Similarly, for An. gambiae (s.s.), we observed a marginal difference in feeding success between AF (86.00 ± 10.86%) and DHF (98.92 ± 2.65%), but similar fecundity by either method. Compared to DHF, mosquitoes fed using AF survived a similar number of days [Hazard Ratios (HR) for Ae. aegypti = 0.99 (0.75-1.34), P > 0.05; An. arabiensis = 0.96 (0.75-1.22), P > 0.05; and An. gambiae (s.s.) = 1.03 (0.79-1.35), P > 0.05]. Mosquitoes fed via this simple AF method had similar feeding success, fecundity and longevity. The method could potentially be used for laboratory colonization of mosquitoes, where DHF is unfeasible. If improved (e.g. minimizing temperature fluctuations), the approach could possibly also support studies where vectors are artificially infected with blood-borne pathogens.

  1. Simple Statistical Model to Quantify Maximum Expected EMC in Spacecraft and Avionics Boxes

    NASA Technical Reports Server (NTRS)

    Trout, Dawn H.; Bremner, Paul

    2014-01-01

    This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. Test and model data correlation is shown. In addition, this presentation shows application of the power balance and extention of this method to predict the variance and maximum exptected mean of the E-field data. This is valuable for large scale evaluations of transmission inside cavities.

  2. Electromagnetic Launch Technology Assessment. Scientific Basis and Unified Treatment: Forces and Electromechanical Power Conversion (Analytical and Numerical Methods),

    DTIC Science & Technology

    1990-06-01

    on simple railgun accelerators andI homopolar generators. Complex rotating flux compressors would drastically improve the performance of EM launchers...velocities. If this is the direction of improvement, then energies stored in the electric trains built with linear electric motors in Japan and Western I...laboratories which had power supplies 3 already built for other programs ( homopolar generators in conjunction with an inductor and an opening switch

  3. STRUCTURED LEARNING AND TRAINING ENVIRONMENTS--A PREPARATION LABORATORY FOR ADVANCED MAMMALIAN PHYSIOLOGY.

    ERIC Educational Resources Information Center

    FIEL, NICHOLAS J.; JOHNSTON, RAYMOND F.

    A PREPARATION LABORATORY WAS DESIGNED TO FAMILIARIZE STUDENTS IN ADVANCED MAMMALIAN PHYSIOLOGY WITH LABORATORY SKILLS AND TECHNIQUES AND THUS SHORTEN THE TIME THEY SPEND IN SETTING UP ACTUAL EXPERIMENTS. THE LABORATORY LASTS 30 MINUTES, IS FLEXIBLE AND SIMPLE OF OPERATION, AND DOES NOT REQUIRE A PROFESSOR'S PRESENCE. THE BASIC TRAINING UNIT IS THE…

  4. Safety in the Chemical Laboratory: Laboratory Air Quality: Part II. Measurements of Ventilation Rates.

    ERIC Educational Resources Information Center

    Butcher, Samuel S.; And Others

    1985-01-01

    Part I of this paper (SE 538 295) described a simple model for estimating laboratory concentrations of gas phase pollutants. In this part, the measurement of ventilation rates and applications of the model are discussed. The model can provide a useful starting point in planning for safer instructional laboratories. (JN)

  5. Rapid and simple detection of foot-and-mouth disease virus: Evaluation of a cartridge-based molecular detection system for use in basic laboratories.

    PubMed

    Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L

    2018-04-01

    Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  6. [A simple apparatus for controllable drinking without leaks for laboratory rats].

    PubMed

    Huber, D

    1989-01-01

    A simple device for watering laboratory rats is described. It has been made by using commercially available glass tubing (DURAN 50) with outside diameters of 8 mm, 6 mm, and 3 mm, respectively. The tubes were fused at their tips. The drinking tube is fitted to a rubber stopper at the top of a 250 ml soft polyethylene bottle. By this way water-soluble drugs can be administered to rats with high precision.

  7. A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry.

    PubMed

    Yan, Ying; Han, Bingqing; Zeng, Jie; Zhou, Weiyan; Zhang, Tianjiao; Zhang, Jiangtao; Chen, Wenxiang; Zhang, Chuanbao

    2017-08-28

    Potassium is an important serum ion that is frequently assayed in clinical laboratories. Quality assurance requires reference methods; thus, the establishment of a candidate reference method for serum potassium measurements is important. An inductively coupled plasma mass spectrometry (ICP-MS) method was developed. Serum samples were gravimetrically spiked with an aluminum internal standard, digested with 69% ultrapure nitric acid, and diluted to the required concentration. The 39K/27Al ratios were measured by ICP-MS in hydrogen mode. The method was calibrated using 5% nitric acid matrix calibrators, and the calibration function was established using the bracketing method. The correlation coefficients between the measured 39K/27Al ratios and the analyte concentration ratios were >0.9999. The coefficients of variation were 0.40%, 0.68%, and 0.22% for the three serum samples, and the analytical recovery was 99.8%. The accuracy of the measurement was also verified by measuring certified reference materials, SRM909b and SRM956b. Comparison with the ion selective electrode routine method and international inter-laboratory comparisons gave satisfied results. The new ICP-MS method is specific, precise, simple, and low-cost, and it may be used as a candidate reference method for standardizing serum potassium measurements.

  8. Directed evolution: an approach to engineer enzymes.

    PubMed

    Kaur, Jasjeet; Sharma, Rohit

    2006-01-01

    Directed evolution is being used increasingly in industrial and academic laboratories to modify and improve commercially important enzymes. Laboratory evolution is thought to make its biggest contribution in explorations of non-natural functions, by allowing us to distinguish the properties nurtured by evolution. In this review we report the significant advances achieved with respect to the methods of biocatalyst improvement and some critical properties and applications of the modified enzymes. The application of directed evolution has been elaborately demonstrated for protein solubility, stability and catalytic efficiency. Modification of certain enzymes for their application in enantioselective catalysis has also been elucidated. By providing a simple and reliable route to enzyme improvement, directed evolution has emerged as a key technology for enzyme engineering and biocatalysis.

  9. Conversion of deuterium gas to heavy water by catalytic isotopic exchange using wetproof catalyst

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quaiattini, R.J.; McGauley, M.P.; Burns, D.L.

    The invention at Chalk River Nuclear Laboratories of a simple method of wetproofing platinum catalysts allows them to retain their activity in liquid water. High performance catalysts for the hydrogen-water isotope exchange reaction that remain active for years can now be routinely produced. The first commercial application using the ordered-bed-type wetproofed isotope exchange catalyst developed and patented by Atomic Energy of Canada Ltd. has been successfully completed. Approximately 9100 m/sup 3/ of deuterium gas stored at Brookhaven National Laboratory was converted to high grade heavy water. Conversion efficiency exceeded 99.8%. The product D/sub 2/O concentration was 6.7 percentage points highermore » than the feed D/sub 2/ gas.« less

  10. Determination of Total Biotin by Liquid Chromatography Coupled with Immunoaffinity Column Cleanup Extraction: Multilaboratory Testing, Final Action 2016.02.

    PubMed

    Joseph, George; Devi, Ranjani; Marley, Elaine C; Leeman, David

    2018-05-01

    Single- and multilaboratory testing data have provided systematic scientific evidence that a simple, selective, accurate, and precise method can be used as a potential candidate reference method for dispute resolution in determining total biotin in all forms of infant, adult, and/or pediatric formula. Using LC coupled with immunoaffinity column cleanup extraction, the method fully meets the intended purpose and applicability statement in AOAC Standard Method Performance Requirement 2014.005. The method was applied to a cross-section of infant formula and adult nutritional matrixes, and acceptable precision and accuracy were established. The analytical platform is inexpensive, and the method can be used in almost any laboratory worldwide with basic facilities. The immunoaffinity column cleanup extraction is the key step to successful analysis.

  11. Analog Video Authentication and Seal Verification Equipment Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory Lancaster

    Under contract to the US Department of Energy in support of arms control treaty verification activities, the Savannah River National Laboratory in conjunction with the Pacific Northwest National Laboratory, the Idaho National Laboratory and Milagro Consulting, LLC developed equipment for use within a chain of custody regime. This paper discussed two specific devices, the Authentication Through the Lens (ATL) analog video authentication system and a photographic multi-seal reader. Both of these devices have been demonstrated in a field trial, and the experience gained throughout will also be discussed. Typically, cryptographic methods are used to prove the authenticity of digital imagesmore » and video used in arms control chain of custody applications. However, in some applications analog cameras are used. Since cryptographic authentication methods will not work on analog video streams, a simple method of authenticating analog video was developed and tested. A photographic multi-seal reader was developed to image different types of visual unique identifiers for use in chain of custody and authentication activities. This seal reader is unique in its ability to image various types of seals including the Cobra Seal, Reflective Particle Tags, and adhesive seals. Flicker comparison is used to compare before and after images collected with the seal reader in order to detect tampering and verify the integrity of the seal.« less

  12. A simple transformation independent method for outlier definition.

    PubMed

    Johansen, Martin Berg; Christensen, Peter Astrup

    2018-04-10

    Definition and elimination of outliers is a key element for medical laboratories establishing or verifying reference intervals (RIs). Especially as inclusion of just a few outlying observations may seriously affect the determination of the reference limits. Many methods have been developed for definition of outliers. Several of these methods are developed for the normal distribution and often data require transformation before outlier elimination. We have developed a non-parametric transformation independent outlier definition. The new method relies on drawing reproducible histograms. This is done by using defined bin sizes above and below the median. The method is compared to the method recommended by CLSI/IFCC, which uses Box-Cox transformation (BCT) and Tukey's fences for outlier definition. The comparison is done on eight simulated distributions and an indirect clinical datasets. The comparison on simulated distributions shows that without outliers added the recommended method in general defines fewer outliers. However, when outliers are added on one side the proposed method often produces better results. With outliers on both sides the methods are equally good. Furthermore, it is found that the presence of outliers affects the BCT, and subsequently affects the determined limits of current recommended methods. This is especially seen in skewed distributions. The proposed outlier definition reproduced current RI limits on clinical data containing outliers. We find our simple transformation independent outlier detection method as good as or better than the currently recommended methods.

  13. Comparative evaluation of power factor impovement techniques for squirrel cage induction motors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spee, R.; Wallace, A.K.

    1992-04-01

    This paper describes the results obtained from a series of tests of relatively simple methods of improving the power factor of squirrel-cage induction motors. The methods, which are evaluated under controlled laboratory conditions for a 10-hp, high-efficiency motor, include terminal voltage reduction; terminal static capacitors; and a floating'' winding with static capacitors. The test results are compared with equivalent circuit model predictions that are then used to identify optimum conditions for each of the power factor improvement techniques compared with the basic induction motor. Finally, the relative economic value, and the implications of component failures, of the three methods aremore » discussed.« less

  14. A filter paper dry blood spot procedure for acute intermittent porphyria population screening by use of whole blood uroporphyrinogen-I-synthase assay.

    PubMed

    Johansson, L; Thunell, S; Wetterberg, L

    1984-03-13

    A filter paper dry blood spot procedure for the determination of whole blood uroporphyrinogen-I-synthase (UIS) activity is presented. The method is based on the concept of enzyme specific activity, the enzyme activity being related to the haemoglobin concentration of the assay sample. The diagnostic capacity with regard to the acute intermittent porphyria (AIP) gene carrier state is shown to be equivalent to that of a washed red cell reference method. On grounds of easy capillary blood sampling, uncomplicated and safe mail specimen transport and simple laboratory reception routines, the method is stated to be well adapted for use in AIP preadolescent population screening.

  15. Effect of genetic algorithm as a variable selection method on different chemometric models applied for the analysis of binary mixture of amoxicillin and flucloxacillin: A comparative study

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed

    2016-03-01

    Different chemometric models were applied for the quantitative analysis of amoxicillin (AMX), and flucloxacillin (FLX) in their binary mixtures, namely, partial least squares (PLS), spectral residual augmented classical least squares (SRACLS), concentration residual augmented classical least squares (CRACLS) and artificial neural networks (ANNs). All methods were applied with and without variable selection procedure (genetic algorithm GA). The methods were used for the quantitative analysis of the drugs in laboratory prepared mixtures and real market sample via handling the UV spectral data. Robust and simpler models were obtained by applying GA. The proposed methods were found to be rapid, simple and required no preliminary separation steps.

  16. A Simple "Tubeless" Telescope

    ERIC Educational Resources Information Center

    Straulino, S.; Bonechi, L.

    2010-01-01

    Two lenses make it possible to create a simple telescope with quite large magnification. The set-up is very simple and can be reproduced in schools, provided the laboratory has a range of lenses with different focal lengths. In this article, the authors adopt the Keplerian configuration, which is composed of two converging lenses. This instrument,…

  17. Recent development of the passive vibration control method

    NASA Astrophysics Data System (ADS)

    Ishida, Yukio

    2012-05-01

    This paper introduces new passive vibration suppression methods developed recently in our laboratory. First, two methods used to suppress steady-state resonances are explained. One is the improvement of the efficiency of a ball balancer. A simple method to eliminate the influence of friction of balls and to improve its efficiency is introduced. The other is an effective method that utilizes the discontinuous spring characteristics. Secondly, a method to eliminate unstable ranges in rotor systems is explained. Unstable ranges in an asymmetrical shaft, and in a hollow rotor partially filled with liquid, are eliminated by the discontinuous spring characteristics. Thirdly, a method to suppress self-excited oscillations is explained. Self-excited oscillations due to internal damping and rubbing are discussed. Finally, the methods of using a pendulum or roller type absorbers to suppress torsional vibrations are explained.

  18. A Simple Optical Waveguide Experiment.

    ERIC Educational Resources Information Center

    Phelps, J.; Sambles, J. R.

    1989-01-01

    Describes a thin film rectangular dielectric waveguide and its laboratory use. Discusses the theory of uniaxial thin film waveguides with mathematical expressions and the laboratory procedures for a classroom experiment with diagrams. (Author/YP)

  19. Determination of Absolute Zero Using a Computer-Based Laboratory

    ERIC Educational Resources Information Center

    Amrani, D.

    2007-01-01

    We present a simple computer-based laboratory experiment for evaluating absolute zero in degrees Celsius, which can be performed in college and undergraduate physical sciences laboratory courses. With a computer, absolute zero apparatus can help demonstrators or students to observe the relationship between temperature and pressure and use…

  20. A Simple Laboratory Exercise for Ethanol Production by Immobilized Bakery Yeasts ("Saccharomyces Cerevisiae")

    ERIC Educational Resources Information Center

    Vullo, Diana L.; Wachsman, Monica B.

    2005-01-01

    This laboratory experiment was designed for Chemistry, Food Technology, Biology, and Chemical Engineering undergraduate students. This laboratory experience shows the advantages of immobilized bakery yeasts in ethanol production by alcoholic fermentation. The students were able to compare the ethanol production yields by free or calcium alginate…

  1. A Laboratory Course in Clinical Biochemistry Emphasizing Interest and Relevance

    ERIC Educational Resources Information Center

    Schwartz, Peter L.

    1975-01-01

    Ten laboratory experiments are described which are used in a successful clinical biochemistry laboratory course (e.g. blood alcohol, glucose tolerance, plasma triglycerides, coronary risk index, gastric analysis, vitamin C and E). Most of the experiments are performed on the students themselves using simple equipment with emphasis on useful…

  2. Sensing of fluid viscoelasticity from piezoelectric actuation of cantilever flexural vibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Jeongwon; Jeong, Seongbin; Kim, Seung Joon

    2015-01-15

    An experimental method is proposed to measure the rheological properties of fluids. The effects of fluids on the vibration actuated by piezoelectric patches were analyzed and used in measuring viscoelastic properties. Fluid-structure interactions induced changes in the beam vibration properties and frequency-dependent variations of the complex wavenumber of the beam structure were used in monitoring these changes. To account for the effects of fluid-structure interaction, fluids were modelled as a simple viscoelastic support at one end of the beam. The measured properties were the fluid’s dynamic shear modulus and loss tangent. Using the proposed method, the rheological properties of variousmore » non-Newtonian fluids were measured. The frequency range for which reliable viscoelasticity results could be obtained was 10–400 Hz. Viscosity standard fluids were tested to verify the accuracy of the proposed method, and the results agreed well with the manufacturer’s reported values. The simple proposed laboratory setup for measurements was flexible so that the frequency ranges of data acquisition were adjustable by changing the beam’s mechanical properties.« less

  3. Principles and implementations of electrolysis systems for water splitting

    DOE PAGES

    Xiang, Chengxiang; Papadantonakis, Kimberly M.; Lewis, Nathan S.

    2016-02-12

    Efforts to develop renewable sources of carbon-neutral fuels have brought a renewed focus to research and development of sunlight-driven water-splitting systems. Electrolysis of water to produce H 2 and O 2 gases is the foundation of such systems, is conceptually and practically simple, and has been practiced both in the laboratory and industrially for many decades. In this Focus article, the fundamentals of water splitting and practices which distinguish commercial water-electrolysis systems from simple laboratory-scale demonstrations are described.

  4. A simple method to predict body temperature of small reptiles from environmental temperature.

    PubMed

    Vickers, Mathew; Schwarzkopf, Lin

    2016-05-01

    To study behavioral thermoregulation, it is useful to use thermal sensors and physical models to collect environmental temperatures that are used to predict organism body temperature. Many techniques involve expensive or numerous types of sensors (cast copper models, or temperature, humidity, radiation, and wind speed sensors) to collect the microhabitat data necessary to predict body temperatures. Expense and diversity of requisite sensors can limit sampling resolution and accessibility of these methods. We compare body temperature predictions of small lizards from iButtons, DS18B20 sensors, and simple copper models, in both laboratory and natural conditions. Our aim was to develop an inexpensive yet accurate method for body temperature prediction. Either method was applicable given appropriate parameterization of the heat transfer equation used. The simplest and cheapest method was DS18B20 sensors attached to a small recording computer. There was little if any deficit in precision or accuracy compared to other published methods. We show how the heat transfer equation can be parameterized, and it can also be used to predict body temperature from historically collected data, allowing strong comparisons between current and previous environmental temperatures using the most modern techniques. Our simple method uses very cheap sensors and loggers to extensively sample habitat temperature, improving our understanding of microhabitat structure and thermal variability with respect to small ectotherms. While our method was quite precise, we feel any potential loss in accuracy is offset by the increase in sample resolution, important as it is increasingly apparent that, particularly for small ectotherms, habitat thermal heterogeneity is the strongest influence on transient body temperature.

  5. A Simple Experiment Demonstrating the Allosteric Regulation of Yeast Pyruvate Kinase.

    ERIC Educational Resources Information Center

    Taber, Richard L.; Campbell, Angela; Spencer, Scott

    1998-01-01

    Explains the procedures used to determine the regulatory properties of yeast pyruvate kinase. Involves a partial purification using PEG precipitation that can be done in one laboratory period with simple equipment. (DDR)

  6. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Addleman, Raymond S.; Naes, Benjamin E.; McNamara, Bruce K.

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmentalmore » sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2F 2 and UO 2(NO 3) 2, U 3O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.« less

  7. Notes: Water Flow and Chemical Retardation in Soils: A Simple Effective Laboratory Demonstration.

    ERIC Educational Resources Information Center

    Bowman, R. S.; And Others

    1988-01-01

    Describes a laboratory demonstration that illustrates principles of miscible displacement and chemical retardation in soils. Discusses how the experimental apparatus can be constructed from readily available materials. (TW)

  8. Simple Exploration Apparatus for the Introductory Physics Laboratory

    ERIC Educational Resources Information Center

    Campbell, Thomas C.

    1977-01-01

    Discusses the laboratory portion of a beginning noncalculus physics course that uses concrete examples of abstract concepts. Describes the use of coffee cans to explain oscillations and plastic darts to illustrate collisions. (MLH)

  9. Maui Space Surveillance System Satellite Categorization Laboratory

    NASA Astrophysics Data System (ADS)

    Deiotte, R.; Guyote, M.; Kelecy, T.; Hall, D.; Africano, J.; Kervin, P.

    The MSSS satellite categorization laboratory is a fusion of robotics and digital imaging processes that aims to decompose satellite photometric characteristics and behavior in a controlled setting. By combining a robot, light source and camera to acquire non-resolved images of a model satellite, detailed photometric analyses can be performed to extract relevant information about shape features, elemental makeup, and ultimately attitude and function. Using the laboratory setting a detailed analysis can be done on any type of material or design and the results cataloged in a database that will facilitate object identification by "curve-fitting" individual elements in the basis set to observational data that might otherwise be unidentifiable. Currently the laboratory has created, an ST-Robotics five degree of freedom robotic arm, collimated light source and non-focused Apogee camera have all been integrated into a MATLAB based software package that facilitates automatic data acquisition and analysis. Efforts to date have been aimed at construction of the lab as well as validation and verification of simple geometric objects. Simple tests on spheres, cubes and simple satellites show promising results that could lead to a much better understanding of non-resolvable space object characteristics. This paper presents a description of the laboratory configuration and validation test results with emphasis on the non-resolved photometric characteristics for a variety of object shapes, spin dynamics and orientations. The future vision, utility and benefits of the laboratory to the SSA community as a whole are also discussed.

  10. Evaluation of the performance of existing non-laboratory based cardiovascular risk assessment algorithms

    PubMed Central

    2013-01-01

    Background The high burden and rising incidence of cardiovascular disease (CVD) in resource constrained countries necessitates implementation of robust and pragmatic primary and secondary prevention strategies. Many current CVD management guidelines recommend absolute cardiovascular (CV) risk assessment as a clinically sound guide to preventive and treatment strategies. Development of non-laboratory based cardiovascular risk assessment algorithms enable absolute risk assessment in resource constrained countries. The objective of this review is to evaluate the performance of existing non-laboratory based CV risk assessment algorithms using the benchmarks for clinically useful CV risk assessment algorithms outlined by Cooney and colleagues. Methods A literature search to identify non-laboratory based risk prediction algorithms was performed in MEDLINE, CINAHL, Ovid Premier Nursing Journals Plus, and PubMed databases. The identified algorithms were evaluated using the benchmarks for clinically useful cardiovascular risk assessment algorithms outlined by Cooney and colleagues. Results Five non-laboratory based CV risk assessment algorithms were identified. The Gaziano and Framingham algorithms met the criteria for appropriateness of statistical methods used to derive the algorithms and endpoints. The Swedish Consultation, Framingham and Gaziano algorithms demonstrated good discrimination in derivation datasets. Only the Gaziano algorithm was externally validated where it had optimal discrimination. The Gaziano and WHO algorithms had chart formats which made them simple and user friendly for clinical application. Conclusion Both the Gaziano and Framingham non-laboratory based algorithms met most of the criteria outlined by Cooney and colleagues. External validation of the algorithms in diverse samples is needed to ascertain their performance and applicability to different populations and to enhance clinicians’ confidence in them. PMID:24373202

  11. Reflotron cholesterol measurement in general practice: accuracy and detection of errors.

    PubMed

    Ball, M J; Robertson, I K; Woods, M

    1994-11-01

    Comparison of cholesterol determinations by nurses using a Reflotron analyser in a general practice setting showed a good correlation with plasma cholesterol determinations by wet chemistry in a clinical biochemistry laboratory. A limited number of comparisons did, however, give a much lower result on the Reflotron. In an experimental situation, small sample volumes (which could result from poor technique) were shown to produce falsely low readings. A simple method which may immediately detect falsely low Reflotron readings is discussed.

  12. Automated single-slide staining device

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M. (Inventor)

    1977-01-01

    A simple apparatus and method is disclosed for making individual single Gram stains on bacteria inoculated slides to assist in classifying bacteria in the laboratory as Gram-positive or Gram-negative. The apparatus involves positioning a single inoculated slide in a stationary position and thereafter automatically and sequentially flooding the slide with increments of a primary stain, a mordant, a decolorizer, a counterstain and a wash solution in a sequential manner without the individual lab technician touching the slide and with minimum danger of contamination thereof from other slides.

  13. Absolute Bunch Length Measurements at the ALS by Incoherent Synchrotron Radiation Fluctuation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filippetto, D.; /Frascati; Sannibale, F.

    2008-01-24

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and tested a simple scheme based on this principle that allows for the absolute measurement of the bunch length. A description of the method and the experimental results are presented.

  14. A High Voltage Asymmetric Waveform Generator for FAIMS

    PubMed Central

    Canterbury, Jesse D.; Gladden, James; Buck, Lon; Olund, Roy; MacCoss, Michael J.

    2010-01-01

    High field asymmetric waveform ion mobility spectrometry (FAIMS) has been used increasingly in recent years as an additional method of ion separation and selection prior to mass spectrometry. The FAIMS electrodes are relatively simple to design and fabricate for laboratories wishing to implement their own FAIMS designs. However, construction of the electronics apparatus needed to produce the required high magnitude asymmetric electric field oscillating at a frequency of several hundred kilohertz is not trivial. Here we present an entirely custom-built electronics setup capable of supplying the required waveforms and voltages. The apparatus is relatively simple and inexpensive to implement. We also present data acquired on this system demonstrating the use of FAIMS as a gas phase ion filter interface to an ion trap mass spectrometer. PMID:20332067

  15. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    DOEpatents

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  16. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis

    PubMed Central

    Mohammed, Emad A.; Naugler, Christopher

    2017-01-01

    Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand. PMID:28400996

  17. Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum.

    PubMed

    Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing

    2014-05-01

    Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of P. falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8-24 h followed by routine culture. When cultures with 27-60% of ring stage were synchronized using this procedure, 70-93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum

    PubMed Central

    Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M.; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing

    2014-01-01

    Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of Plasmodium falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8–24 h followed by routine culture. When cultures with 27–60% of ring stage were synchronized using this procedure, 70–93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. PMID:24632190

  19. A method for the purification of bacterial flagellin that allows simple upscaling.

    PubMed

    Hiriart, Yanina; Errea, Agustina; González Maciel, Dolores; Lopez, Juan Carlos; Rumbo, Martin

    2012-01-01

    There is a growing interest in enterobacterial flagellins that may result in a demand to produce flagellin on an industrial scale for possible applications as an adjuvant, immunomodulatory agent or vaccine antigen. Traditionally, small-scale production of flagellin has occurred in the laboratory by flagellar shearing of bacterial surfaces and subsequent ultracentrifugation. The main drawback of this method is the need to use low-agitation cultures to avoid the loss of flagella due to shearing during culture. In the present work, we describe a scalable protocol for the production of flagellin with higher yields than traditional laboratory-scale protocols. The use of cross-flow filtration to concentrate bacterial cultures combines extensive shearing of flagella with a reduction in volume, greatly simplifying downstream processing. This technique also allows the use of highly-agitated culture conditions because any sheared flagella are retained in the bacterial concentrate. Flagella obtained with this procedure showed in vivo and in vitro innate activating capacities similar to those of flagella produced at laboratory scale. This procedure is flexible, allowing an increase in production scale, an enhancement of flagellin yield and no requirement for expensive equipment.

  20. Simultaneous Speciation, Structure, and Equilibrium Constant Determination in the Ni2+-EDTA-CN- Ternary System via High-Resolution Laboratory X-ray Absorption Fine Structure Spectroscopy and Theoretical Calculations.

    PubMed

    Bajnóczi, Éva G; Németh, Zoltán; Vankó, György

    2017-11-20

    Even quite simple chemical systems can involve many components and chemical states, and sometimes it can be very difficult to differentiate them by their hardly separable physical-chemical properties. The Ni II -EDTA-CN - (EDTA = ethylenediaminetetraacetic acid) ternary system is a good example for this problem where, in spite of its fairly simple components and numerous investigations, several molecular combinations can exist, all of them not having been identified unambiguously yet. In order to achieve a detailed understanding of the reaction steps and chemical equilibria, methods are required in which the structural transitions in the different reaction steps can be followed via element-selective complex spectral feature sets. With the help of our recently developed von Hámos type high-resolution laboratory X-ray absorption spectrometer, both the structural variations and stability constants of the forming complexes were determined from the same measurement series, proving that X-ray absorption spectroscopy can be considered as a multifaced, table-top tool in coordination chemistry. Furthermore, with the help of theoretical calculations, independent structural evidence was also given for the formation of the [NiEDTA(CN)] 3- mixed complex.

  1. Assay for the simultaneous determination of guanidinoacetic acid, creatinine and creatine in plasma and urine by capillary electrophoresis UV-detection.

    PubMed

    Zinellu, Angelo; Sotgia, Salvatore; Zinellu, Elisabetta; Chessa, Roberto; Deiana, Luca; Carru, Ciriaco

    2006-03-01

    Guanidinoacetic acid (GAA) measurement has recently become of great interest for the diagnosis of creatine (Cn) metabolism disorders, and research calls for rapid and inexpensive methods for its detection in plasma and urine in order to assess a large number of patients. We propose a new assay for the measurement of GAA by a simple CZE UV-detection without previous sample derivatization. Plasma samples were filtered by Microcon-10 microconcentrators and directly injected into the capillary, while for urine specimens a simple water dilution before injection was needed. A baseline separation was obtained in less than 8 min using a 60.2 cm x 75 microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer pH 2.25 at 15 degrees C. The performance of the developed method was assessed by measuring plasma creatinine and Cn in 32 normal subjects and comparing the data obtained by the new method with those found with the previous CE assay. Our new method seems to be an inexpensive, fast and specific tool to assess a large number of patients both in clinical and in research laboratories.

  2. Microburger Biochemistry: Extraction and Spectral Characterization of Myoglyobin from Hamburger

    NASA Astrophysics Data System (ADS)

    Bylkas, Sheri A.; Andersson, Laura A.

    1997-04-01

    This experiment provides a demonstration of useful biochemical methods at a Basic or Advanced Level, depending upon the available spectrophotometric equipment. The protocol combines protein extraction, ox-i-dation and reduction, and simple spectroscopic analysis, as well as gel filtration chromatography and generation/analysis of spectral scans. Mammalian myoglobin (Mb) is a monomeric O2-binding protein that functions in muscle to store oxygen. The single iron protoporphyrin IX (heme) group is bound to protein by the amino acid Histidine93. The common, stable forms, Met-Mb and Oxy-Mb are studied because in a non-living system, red Oxy-Mb is converted to brown Met-Mb as bound O2 molecule is released. Mb is easily extracted from steak, to illustrate and address why fresh meat is red and aged meat is brown; the protein has unique spectral properties that are diagnostic for characterization of sample identity. After application of heme redox chemical methods, the MetMb or OxyMb samples can be studied spectroscopically. The color change between Oxy-Mb and Met-Mb is dramatic (illustrating bright red fresh meat vs. brown older meat), and method(s) used in this laboratory are simple, inexpensive, and non-harmful to the student.

  3. Evaluation of thin-layer chromatography methods for quality control of commercial products containing Aesculus hippocastanum, Turnera diffusa, Matricaria recutita, Passiflora incarnata, and Tilia occidentalis.

    PubMed

    Ramírez-Durón, Rosalba; Ceniceros-Almaguer, Lucía; Salazar-Aranda, Ricardo; Salazar-Cavazos, Ma de la Luz; Waksman de Torres, Noemi

    2007-01-01

    In Mexico, plant-derived products with health claims are sold as herbal dietary supplements, and there are no rules for their legal quality control. Aesculus hippocastanum, Turnera diffusa, Matricaria recutita, Passiflora incarnata, and Tilia occidentalis are some of the major commercial products obtained from plants used in this region. In this paper, we describe the effectiveness of thin-layer chromatography methods to provide for the quality control of several commercial products containing these plants. Standardized extracts were used. Of the 49 commercial products analyzed, only 32.65% matched the chromatographic characteristic of standardized extracts. A significant number of commercial products did not match their label, indicating a problem resulting from the lack of regulation for these products. The proposed methods are simple, sensitive, and specific and can be used for routine quality control of raw herbals and formulations of the tested plants. The results obtained show the need to develop simple and reliable analytical methods that can be performed in any laboratory for the purpose of quality control of dietary supplements or commercial herbal products sold in Mexico.

  4. Evaluation of VIDAS Salmonella (SLM) easy Salmonella method for the detection of Salmonella in a variety of foods: collaborative study.

    PubMed

    Crowley, Erin; Bird, Patrick; Fisher, Kiel; Goetz, Katherine; Benzinger, M Joseph; Agin, James; Goins, David; Johnson, Ronald L

    2011-01-01

    The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.

  5. 'The artist's piece is already in the stone': constructing creativity in paleontology laboratories.

    PubMed

    Wylie, Caitlin Donahue

    2015-02-01

    Laboratory technicians are typically portrayed as manual workers following routine procedures to produce scientific data. However, technicians in vertebrate paleontology laboratories often describe their work in terms of creativity and artistry. Fossil specimens undergo extensive preparation--including rock removal, damage repair, and reconstruction of missing parts--to become accessible to researchers. Technicians called 'fossil preparators' choose, apply, and sometimes invent these preparation methods. They have no formal training, no standard protocols, and few publications to consult on techniques. Despite the resulting diversity of people and practices, preparators and their work are usually absent from research publications, making them 'invisible technicians' in Steven Shapin's sense. But preparators reject the view of their work as predictable or simple; in particular, many preparators value art training, the aesthetics of prepared fossils, and the process of creative problem-solving in their work. Based on interviews and participant observation and drawing from literature in science studies, sociology of work, and anthropology of craft, I ask why these technicians compare themselves with artists and how this portrayal affects scientific practice and social order in laboratories. I argue that associating artistry and creativity with their work distances preparators from ideas of unskilled technical work and technicians' low status, thus improving their social role in the laboratory community and preserving their power over laboratory practices.

  6. Introducing Laboratory Safety.

    ERIC Educational Resources Information Center

    DeLorenzo, Ronald

    1985-01-01

    Presents a simple, 10-item quiz designed to make students aware that they must learn laboratory safety. The items include questions on acid/base accidents, several types of fire extinguishers, and safety glassses. Answers and some explanations are included. (DH)

  7. A simple, rapid atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry method for the determination of 25-hydroxyvitamin D2 and D3.

    PubMed

    Garg, Uttam; Munar, Ada; Frazee, Clinton; Scott, David

    2012-09-01

    Vitamin D plays a vital role not only in bone health but also in pathophysiology of many other body functions. In recent years, there has been significant increase in testing of 25-hydroxyvitamin D (25-OH vitamin D), a marker of vitamin D deficiency. The most commonly used methods for the measurement of 25-OH vitamin D are immunoassays and liquid chromatography tandem mass spectrometry (LC-MS-MS). Since immunoassays suffer from inaccuracies and interferences, LC-MS-MS is a preferred method. In LC-MS-MS methods, 25-OH vitamin D is extracted from serum or plasma by solid-phase or liquid-phase extraction. Because these extraction methods are time consuming, we developed an easy method that uses simple protein precipitation followed by injection of the supernatant to LC-MS-MS. Several mass-to-charge (m/z) ratio transitions, including commonly used transitions based on water loss, were evaluated and several tube types were tested. The optimal transitions for 25-OH vitamin D2 and D3 were 395.5 > 269.5 and 383.4 > 257.3, respectively. The reportable range of the method was 1-100 ng/mL, and repeatability (within-run) and within-laboratory imprecision were <4% and <6%, respectively. The method agreed well with the solid-phase extraction methods. © 2012 Wiley Periodicals, Inc.

  8. UV-Vis Spectrophotometric Analysis and Quantification of Glyphosate for an Interdisciplinary Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Felton, Daniel E.; Ederer, Martina; Steffens, Timothy; Hartzell, Patricia L.; Waynant, Kristopher V.

    2018-01-01

    Glyphosate (N-(phosphonomethyl)glycine) is the most widely used herbicide on earth. A simple assay to quantify glyphosate concentrations in environmental samples was developed as part of an interdisciplinary effort linking introductory laboratory courses in chemistry, biology, and microbiology. In this 3 h laboratory experiment, students used…

  9. Simple and Rapid System for Two-Dimensional Gel Electrophoresis Technique: A Laboratory Exercise for High School Students

    ERIC Educational Resources Information Center

    Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay

    2018-01-01

    Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky…

  10. How Efficient is a Laboratory Burner in Heating Water?

    ERIC Educational Resources Information Center

    Jansen, Michael P.

    1997-01-01

    Describes an experiment in which chemistry students determine the efficiency of a laboratory burner used to heat water. The reaction is assumed to be the complete combustion of methane, CH4. The experiment is appropriate for secondary school chemistry students familiar with heats of reaction and simple calorimetry. Contains pre-laboratory and…

  11. Ranking protective coatings: Laboratory vs. field experience

    NASA Astrophysics Data System (ADS)

    Conner, Jeffrey A.; Connor, William B.

    1994-12-01

    Environmentally protective coatings are used on a wide range of gas turbine components for survival in the harsh operating conditions of engines. A host of coatings are commercially available to protect hot-section components, ranging from simple aluminides to designer metallic overlays and ceramic thermal barrier coatings. A variety of coating-application processes are available, and they range from simple pack cementation processing to complex physical vapor deposition, which requires multimillion dollar facilities. Detailed databases are available for most coatings and coating/process combinations for a range of laboratory tests. Still, the analysis of components actually used in engines often yields surprises when compared against predicted coating behavior from laboratory testing. This paper highlights recent work to develop new laboratory tests that better simulate engine environments. Comparison of in-flight coating performance as well as industrial and factory engine testing on a range of hardware is presented along with laboratory predictions from standard testing and from recently developed cyclic burner-rig testing.

  12. Can simple tank changes benefit the welfare of laboratory zebrafish Danio rerio?

    PubMed

    Lee, C J; Tyler, C R; Paull, G C

    2018-03-01

    This study examined the effects of simple changes in the tank environment on the wellbeing of laboratory-maintained zebrafish Danio rerio. Groups of D. rerio were either housed in stable environments (where they were maintained in the same tanks throughout the study) or in environments subject to change (where they were periodically moved to novel but identical tanks) and the effects of these treatments on morphometry, reproductive success and aggressive behaviour assessed. No effect of simple tank changes was found on body condition, reproductive output or aggression, for the periods of time studied, indicating that more complex scenarios in housing tank conditions are required for significant welfare benefits for captive D. rerio. © 2018 The Fisheries Society of the British Isles.

  13. Attenuation of radiation from distributed gamma sources as a function of wall thickness of a concrete blockhouse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmoke, M. A.; Rexroad, R. E.; Tiller, H. J.

    1963-06-15

    The experiment described constitutes part of the shielding program conducted by Army Nuclear Defense Laboratory and was designed to experimentally verify theoretical calculations used to predict the amount of radiation protection afforded by above-ground structures in a fallout radiation field. This method requires the knowledge of some physical parameters of a structure such as mass thickness of the walls and the geometric orientation of the detectors within the structure. From this information, a reduction factor for any given structure may be calculated. This Laboratory's experimental program was initially begun by measuring the attenuation of a simple structure with no complicatingmore » internal or external geometries and will proceed to more complex structures with basements, interior partitions, and upper floors. (auth)« less

  14. Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeany, Badr A.

    2013-09-01

    Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively.

  15. An investigation of normal urine with a creatinine concentration under the cutoff of 20 mg/dL for specimen validity testing in a toxicology laboratory.

    PubMed

    Holden, Brad; Guice, Erica A

    2014-05-01

    In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.

  16. Measuring methylphenidate response in attention-deficit/hyperactvity disorder: how are laboratory classroom-based measures related to parent ratings?

    PubMed

    Sonuga-Barke, Edmund J S; Coghill, David; DeBacker, Marc; Swanson, James

    2009-12-01

    Methylphenidate (MPH) is an efficacious and normally well-tolerated treatment for attention-deficit/hyperactivity disorder (ADHD). Although treatment effects are usually assessed using parent-rating scales, these can be supplemented by more objective methods. Here we examine the associations between ratings and one such method, assessments made across the day in the laboratory classroom. Comparison of Methylphenidates in the Analog Classroom Setting (COMACS) was made in a large (n = 184) placebo-controlled trial comparing Equasym XL/Metadate CD, Concerta, and placebo (PLA) using a Laboratory School protocol. Therapeutic effects were measured using direct observation, scores on a simple math productivity task and parent ratings. Treatment effects were observed on all measures. Laboratory measures were correlated with each other, most strongly between Swanson, Kotkin, Agler, M-Flynn and Pelham Scale (SKAMP) inattention and Permanent Product Measure of Performance (PERMP). Parental ratings were correlated with classroom measures during the main morning period (1.5-4.5 hours after dosing) and to a lesser extent in the afternoon (6.0-7.5 hours after dosing), but not, by and large, immediately after dosing or in the evening. The morning correlations seemed stronger for female than for male participants. The results suggest that parental ratings and direct observations tap different aspects of MPH response and that both may be required for comprehensive assessment.

  17. A simple method for rapid microbial identification from positive monomicrobial blood culture bottles through matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Lin, Jung-Fu; Ge, Mao-Cheng; Liu, Tsui-Ping; Chang, Shih-Cheng; Lu, Jang-Jih

    2017-06-30

    Rapid identification of microbes in the bloodstream is crucial in managing septicemia because of its high disease severity, and direct identification from positive blood culture bottles through matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can shorten the turnaround time. Therefore, we developed a simple method for rapid microbiological identification from positive blood cultures by using MALDI-TOF MS. We modified previously developed methods to propose a faster, simpler and more economical method, which includes centrifugation and hemolysis. Specifically, our method comprises two-stage centrifugation with gravitational acceleration (g) at 600g and 3000g, followed by the addition of a lysis buffer and another 3000g centrifugation. In total, 324 monomicrobial bacterial cultures were identified. The success rate of species identification was 81.8%, which is comparable with other complex methods. The identification success rate was the highest for Gram-negative aerobes (85%), followed by Gram-positive aerobes (78.2%) and anaerobes (67%). The proposed method requires less than 10 min, costs less than US$0.2 per usage, and facilitates batch processing. We conclude that this method is feasible for clinical use in microbiology laboratories, and can serve as a reference for treatments or further complementary diagnostic testing. Copyright © 2017. Published by Elsevier B.V.

  18. Prediction of Frequency for Simulation of Asphalt Mix Fatigue Tests Using MARS and ANN

    PubMed Central

    Fakhri, Mansour

    2014-01-01

    Fatigue life of asphalt mixes in laboratory tests is commonly determined by applying a sinusoidal or haversine waveform with specific frequency. The pavement structure and loading conditions affect the shape and the frequency of tensile response pulses at the bottom of asphalt layer. This paper introduces two methods for predicting the loading frequency in laboratory asphalt fatigue tests for better simulation of field conditions. Five thousand (5000) four-layered pavement sections were analyzed and stress and strain response pulses in both longitudinal and transverse directions was determined. After fitting the haversine function to the response pulses by the concept of equal-energy pulse, the effective length of the response pulses were determined. Two methods including Multivariate Adaptive Regression Splines (MARS) and Artificial Neural Network (ANN) methods were then employed to predict the effective length (i.e., frequency) of tensile stress and strain pulses in longitudinal and transverse directions based on haversine waveform. It is indicated that, under controlled stress and strain modes, both methods (MARS and ANN) are capable of predicting the frequency of loading in HMA fatigue tests with very good accuracy. The accuracy of ANN method is, however, more than MARS method. It is furthermore shown that the results of the present study can be generalized to sinusoidal waveform by a simple equation. PMID:24688400

  19. Prediction of frequency for simulation of asphalt mix fatigue tests using MARS and ANN.

    PubMed

    Ghanizadeh, Ali Reza; Fakhri, Mansour

    2014-01-01

    Fatigue life of asphalt mixes in laboratory tests is commonly determined by applying a sinusoidal or haversine waveform with specific frequency. The pavement structure and loading conditions affect the shape and the frequency of tensile response pulses at the bottom of asphalt layer. This paper introduces two methods for predicting the loading frequency in laboratory asphalt fatigue tests for better simulation of field conditions. Five thousand (5000) four-layered pavement sections were analyzed and stress and strain response pulses in both longitudinal and transverse directions was determined. After fitting the haversine function to the response pulses by the concept of equal-energy pulse, the effective length of the response pulses were determined. Two methods including Multivariate Adaptive Regression Splines (MARS) and Artificial Neural Network (ANN) methods were then employed to predict the effective length (i.e., frequency) of tensile stress and strain pulses in longitudinal and transverse directions based on haversine waveform. It is indicated that, under controlled stress and strain modes, both methods (MARS and ANN) are capable of predicting the frequency of loading in HMA fatigue tests with very good accuracy. The accuracy of ANN method is, however, more than MARS method. It is furthermore shown that the results of the present study can be generalized to sinusoidal waveform by a simple equation.

  20. Submillimeter Measurements of Photolysis Products in Interstellar Ice Analogs: A New Experimental Technique

    NASA Technical Reports Server (NTRS)

    Milam, Stefanie N.; Weaver, Susanna Widicus

    2012-01-01

    Over 150 molecular species have been confirmed in space, primarily by their rotational spectra at millimeter/submillimeter wavelengths, which yield an unambiguous identification. Many of the known interstellar organic molecules cannot be explained by gas-phase chemistry. It is now presumed that they are produced by surface reactions of the simple ices and/or grains observed and released into the gas phase by sublimation, sputtering, etc. Additionally, the chemical complexity found in meteorites and samples returned from comets far surpasses that of the remote detections for the interstellar medium (ISM), comets, and planetary atmospheres. Laboratory simulations of interstellar/cometary ices have found, from the analysis of the remnant residue of the warmed laboratory sample, that such molecules are readily formed; however, it has yet to be determined if they are formed during the warm phase or within the ice during processing. Most analysis of the ice during processing reveals molecular changes, though the exact quantities and species formed are highly uncertain with current techniques due to overwhelming features of simple ices. Remote sensing with high resolution spectroscopy is currently the only method to detect trace species in the ISM and the primary method for comets and icy bodies in the Solar System due to limitations of sample return. We have recently designed an experiment to simulate interstellar/cometary/planetary ices and detect trace species employing the same techniques used for remote observations. Preliminary results will be presented.

  1. A simple technique for measuring buoyant weight increment of entire, transplanted coral colonies in the field.

    PubMed

    Herler, Jürgen; Dirnwöber, Markus

    2011-10-31

    Estimating the impacts of global and local threats on coral reefs requires monitoring reef health and measuring coral growth and calcification rates at different time scales. This has traditionally been mostly performed in short-term experimental studies in which coral fragments were grown in the laboratory or in the field but measured ex situ. Practical techniques in which growth and measurements are performed over the long term in situ are rare. Apart from photographic approaches, weight increment measurements have also been applied. Past buoyant weight measurements under water involved a complicated and little-used apparatus. We introduce a new method that combines previous field and laboratory techniques to measure the buoyant weight of entire, transplanted corals under water. This method uses an electronic balance fitted into an acrylic glass underwater housing and placed atop of an acrylic glass cube. Within this cube, corals transplanted onto artificial bases can be attached to the balance and weighed at predetermined intervals while they continue growth in the field. We also provide a set of simple equations for the volume and weight determinations required to calculate net growth rates. The new technique is highly accurate: low error of weight determinations due to variation of coral density (< 0.08%) and low standard error (< 0.01%) for repeated measurements of the same corals. We outline a transplantation technique for properly preparing corals for such long-term in situ experiments and measurements.

  2. Manipulating Ratio Spectra for the Spectrophotometric Analysis of Diclofenac Sodium and Pantoprazole Sodium in Laboratory Mixtures and Tablet Formulation

    PubMed Central

    Bhatt, Nejal M.; Chavada, Vijay D.; Sanyal, Mallika; Shrivastav, Pranav S.

    2014-01-01

    Objective. Three sensitive, selective, and precise spectrophotometric methods based on manipulation of ratio spectra, have been developed and validated for the determination of diclofenac sodium and pantoprazole sodium. Materials and Methods. The first method is based on ratio spectra peak to peak measurement using the amplitudes at 251 and 318 nm; the second method involves the first derivative of the ratio spectra (Δλ = 4 nm) using the peak amplitudes at 326.0 nm for diclofenac sodium and 337.0 nm for pantoprazole sodium. The third is the method of mean centering of ratio spectra using the values at 318.0 nm for both the analytes. Results. All the three methods were linear over the concentration range of 2.0–24.0 μg/mL for diclofenac sodium and 2.0–20.0 μg/mL for pantoprazole sodium. The methods were validated according to the ICH guidelines and accuracy, precision, repeatability, and robustness are found to be within the acceptable limit. The results of single factor ANOVA analysis indicated that there is no significant difference among the developed methods. Conclusions. The developed methods provided simple resolution of this binary combination from laboratory mixtures and pharmaceutical preparations and can be conveniently adopted for routine quality control analysis. PMID:24701171

  3. Sensitivity of Polar Stratospheric Ozone Loss to Uncertainties in Chemical Reaction Kinetics

    NASA Technical Reports Server (NTRS)

    Kawa, S. Randolph; Stolarski, Richard S.; Douglass, Anne R.; Newman, Paul A.

    2008-01-01

    Several recent observational and laboratory studies of processes involved in polar stratospheric ozone loss have prompted a reexamination of aspect of out understanding for this key indicator of global change. To a large extent, our confidence in understanding and projecting changes in polar and global ozone is based on our ability to to simulate these process in numerical models of chemistry and transport. These models depend on laboratory-measured kinetic reaction rates and photlysis cross section to simulate molecular interactions. In this study we use a simple box-model scenario for Antarctic ozone to estimate the uncertainty in loss attributable to known reaction kinetic uncertainties. Following the method of earlier work, rates and uncertainties from the latest laboratory evaluation are applied in random combinations. We determine the key reaction and rates contributing the largest potential errors and compare the results to observations to evaluate which combinations are consistent with atmospheric data. Implications for our theoretical and practical understanding of polar ozone loss will be assessed.

  4. E-commerce application study and complementary services in the sector of laboratory diagnostics based on consumers' opinion.

    PubMed

    Kontis, Alexios-Patapios; Siassiakos, Konstantinos; Kaimakamis, Georgios; Lazakidou, Athina

    2010-01-01

    The field of the Laboratory Diagnostics (in vitro), a sector of the field of health services, constitutes an industrial market that includes activities of research, development, production and products distribution that are designated for laboratory use. These products are defined as techno-medical products including various categories of products such as simple medicines, advanced technological systems, etc. Despite the high performance, the enlargement and the increasing trends of the field, it is not recorded the expected progress in the methods and the ways of promotion, trading and supporting of these products in the market. The present paper aims at the investigation of the consumers' opinion and the specification of those services that are possible to be implemented in electronic services and commerce for a strongly competitive advantage for the enterprises of the sector. The analysis of the findings from the Consumer Purchase Decision Centres (CPDC) shows how important it is to implement web-based applications in the proposed services.

  5. A practical approach for linearity assessment of calibration curves under the International Union of Pure and Applied Chemistry (IUPAC) guidelines for an in-house validation of method of analysis.

    PubMed

    Sanagi, M Marsin; Nasir, Zalilah; Ling, Susie Lu; Hermawan, Dadan; Ibrahim, Wan Aini Wan; Naim, Ahmedy Abu

    2010-01-01

    Linearity assessment as required in method validation has always been subject to different interpretations and definitions by various guidelines and protocols. However, there are very limited applicable implementation procedures that can be followed by a laboratory chemist in assessing linearity. Thus, this work proposes a simple method for linearity assessment in method validation by a regression analysis that covers experimental design, estimation of the parameters, outlier treatment, and evaluation of the assumptions according to the International Union of Pure and Applied Chemistry guidelines. The suitability of this procedure was demonstrated by its application to an in-house validation for the determination of plasticizers in plastic food packaging by GC.

  6. A simple, fast, and inexpensive CTAB-PVP-silica based method for genomic DNA isolation from single, small insect larvae and pupae.

    PubMed

    Huanca-Mamani, W; Rivera-Cabello, D; Maita-Maita, J

    2015-07-17

    In this study, we report a modified CTAB-PVP method combined with silicon dioxide (silica) treatment for the extraction of high quality genomic DNA from a single larva or pupa. This method efficiently obtains DNA from small specimens, which is difficult and challenging because of the small amount of starting tissue. Maceration with liquid nitrogen, phenol treatment, and the ethanol precipitation step are eliminated using this methodology. The A260/A280 absorbance ratios of the isolated DNA were approximately 1.8, suggesting that the DNA is pure and can be used for further molecular analysis. The quality of the isolated DNA permits molecular applications and represents a fast, cheap, and effective alternative method for laboratories with low budgets.

  7. A semi-micromethod for determination of oxalate in human plasma.

    PubMed

    Porowski, Tadeusz; Gałasiński, Władysław

    2003-01-01

    An enzymatic semi-micromethod for oxalate determination in human plasma was elaborated. The principle of the method depends on the oxalate isolation from deproteinized plasma, following determination by the calorimetric oxalate oxidase-peroxidase-indamine system. This method protects against internal oxalate losses and excludes an interference of contaminations. Results, obtained by this method, were reliable and ideally suited for use as real normal values (less than or equal to 6 microM) of oxalate content in the plasma of healthy individuals. The elaborated method, which can assay plasma oxalate accurately in normal individuals as well as in hyperoxalemic conditions is superior to those previously used. The procedure of semi-micromethod does not require expensive equipments and apparatus: it is simple and easy to perform in every laboratory and takes little time.

  8. An Inexpensive Robotics Laboratory.

    ERIC Educational Resources Information Center

    Inigo, R. M.; Angulo, J. M.

    1985-01-01

    Describes the design and implementation of a simple robot manipulator. The manipulator has three degrees of freedom and is controlled by a general purpose microcomputer. The basis for the manipulator (which costs under $100) is a simple working model of a crane. (Author/JN)

  9. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing.

    PubMed

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-02-01

    A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R 2 ), using R 2 as the primary metric of assay agreement. However, the use of R 2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Manipulating heat shock protein expression in laboratory animals.

    PubMed

    Tolson, J Keith; Roberts, Stephen M

    2005-02-01

    Upregulation of heat shock proteins (Hsps) has been observed to impart resistance to a wide variety of physical and chemical insults. Elucidation of the role of Hsps in cellular defense processes depends, in part, on the ability to manipulate Hsp expression in laboratory animals. Simple methods of inducing whole body hyperthermia, such as warm water immersion or heating pad application, are effective in producing generalized expression of Hsps. Hsps can be upregulated locally with focused direct or indirect heating, such as with ultrasound or with laser or microwave radiation. Increased Hsp expression in response to toxic doses of xenobiotics has been commonly observed. Some pharmacologic agents are capable of altering Hsps more specifically by affecting processes involved in Hsp regulation. Gene manipulation offers the ability to selectively increase or decrease individual Hsps. Knockout mouse strains and Hsp-overexpressing transgenics have been used successfully to examine the role of specific Hsps in protection against hyperthermia, chemical insults, and ischemia-reperfusion injury. Gene therapy approaches also offer the possibility of selective alteration of Hsp expression. Some methods of increasing Hsp expression have application in specialized areas of research, such cold response, myocardial protection from exercise, and responses to stressful or traumatic stimuli. Each method of manipulating Hsp expression in laboratory animals has advantages and disadvantages, and selection of the best method depends upon the experimental objectives (e.g., the alteration in Hsp expression needed, its timing, and its location) and resources available.

  11. A Simple Lab Exercise Demonstrating Koch's Postulates.

    ERIC Educational Resources Information Center

    Fulton, Michael M.

    1981-01-01

    Describes a laboratory exercise which applies Koch's Postulates to a plant disease, bacterial speck. Includes an explanation of Koch's Postulate, list of equipment needed, advance preparation, outline of the three-week activity, and variations of the laboratory exercise. (DS)

  12. Consequences of using different soil texture determination methodologies for soil physical quality and unsaturated zone time lag estimates.

    PubMed

    Fenton, O; Vero, S; Ibrahim, T G; Murphy, P N C; Sherriff, S C; Ó hUallacháin, D

    2015-11-01

    Elucidation of when the loss of pollutants, below the rooting zone in agricultural landscapes, affects water quality is important when assessing the efficacy of mitigation measures. Investigation of this inherent time lag (t(T)) is divided into unsaturated (t(u)) and saturated (t(s)) components. The duration of these components relative to each other differs depending on soil characteristics and the landscape position. The present field study focuses on tu estimation in a scenario where the saturated zone is likely to constitute a higher proportion of t(T). In such instances, or where only initial breakthrough (IBT) or centre of mass (COM) is of interest, utilisation of site and depth specific "simple" textural class or actual sand-silt-clay percentages to generate soil water characteristic curves with associated soil hydraulic parameters is acceptable. With the same data it is also possible to estimate a soil physical quality (S) parameter for each soil layer which can be used to infer many other physical, chemical and biological quality indicators. In this study, hand texturing in the field was used to determine textural classes of a soil profile. Laboratory methods, including hydrometer, pipette and laser diffraction methods were used to determine actual sand-silt-clay percentages of sections of the same soil profile. Results showed that in terms of S, hand texturing resulted in a lower index value (inferring a degraded soil) than that of pipette, hydrometer and laser equivalents. There was no difference between S index values determined using the pipette, hydrometer and laser diffraction methods. The difference between the three laboratory methods on both the IBT and COM stages of t(u) were negligible, and in this instance were unlikely to affect either groundwater monitoring decisions, or to be of consequence from a policy perspective. When t(u) estimates are made over the full depth of the vadose zone, which may extend to several metres, errors resulting from the use of hydraulic parameters generated from hand texture data will be resultantly greater, and may lead to flawed predictions regarding the achievability of water policy targets. For this reason laboratory analysis, regardless of method, should be preferred to simple field assessments. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. The Effects of Direct Oxygen Supply During Static Cold Preservation of Rat Livers: An Experimental Study.

    PubMed

    Zumrutdal, Emin; Karateke, Faruk; Eser, Pınar Eylem; Turan, Umit; Ozyazici, Sefa; Sozutek, Alper; Gulkaya, Mustafa; Kunt, Mevlut

    2016-12-01

    We aimed to determine the biochemical and histopathologic effects of direct oxygen supply to the preservation fluid of static cold storage system with a simple method on rat livers. Sixteen rats were randomly divided into 2 groups: the control group, which contained Ringer's lactate as preservation fluid; and the oxygen group, which contained oxygen and Ringer's lactate for preservation. Each liver was placed in a bag containing 50 mL Ringer's lactate and placed in ice-filled storage containers. One hundred percent oxygen supplies were given via a simple, inexpensive system created in our laboratory, to the livers in oxygen group. We obtained samples for histopathologic evaluation in the 12th hour. In addition, 3 mL of preservation fluid was subjected to biochemical analysis at 0, sixth, and twelfth hours. Aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, and pH levels were measured from the preservation fluid. In oxygen-supplemented group, the acceleration speed of increase in alanine aminotransferase and lactate dehydrogenase levels at sixth hour and lactate dehydrogenase, alanine aminotransferase, and lactate dehydrogenase levels at 12th hour were statistically significantly reduced. In histopathologic examination, all parameters except ballooning were statistically significantly better in the oxygen-supplemented group. This simple system for oxygenation of liver tissues during static cold storage was shown to be effective with good results in biochemical and histopathologic assessments. Because this is a simple, inexpensive, and easily available method, larger studies are warranted to evaluate its effects (especially in humans).

  14. COMPARATIVE STUDIES OF THREE METHODS FOR MEASURING PEPSIN ACTIVITY

    PubMed Central

    Loken, Merle K.; Terrill, Kathleen D.; Marvin, James F.; Mosser, Donn G.

    1958-01-01

    Comparison has been made of a simple method originated by Absolon and modified in our laboratories for assay of proteolytic activity using RISA (radioactive iodinated serum albumin—Abbott Laboratories), with the commonly used photometric methods of Anson and Kunitz. In this method, pepsin was incubated with an albumin substrate containing RISA, followed by precipitation of the undigested substrate with trichloroacetic acid and measurement of radioactive digestion products in the supernatant fluid. The I131—albumin bond was shown in the present studies to be altered only by the proteolytic activity, and not by the incubation procedures at various values of pH. Any free iodine present originally in the RISA was removed by a single passage through a resin column (amberlite IRA-400-C1). Pepsin was shown to be most stable in solution at a pH of 5.5. Activity of pepsin was shown to be maximal when it was incubated with albumin at a pH of 2.5. Pepsin activity was shown to be altered in the presence of various electrolytes. Pepsin activity measured by the RISA and Anson methods as a function of concentration or of time of incubation indicated that these two methods are in good agreement and are equally sensitive. Consistently smaller standard errors were obtained by the RISA method of pepsin assay than were obtained with either of the other methods. PMID:13587910

  15. Introduction of a rapid, simple radioimmunoassay and quality control scheme for thyroxine.

    PubMed Central

    Nye, L; Hassan, M; Willmott, E; Landon, J

    1976-01-01

    A simple radioimmunoassay has been developed for service purposes to determine serum total thyroxine levels. Only three additions are required, of standard or sample, labelled thyroxine and antibody in polyethylene glycol. After 2 hours' incubation at room temperature the antibody-bound and free fractions are separated by centrifugation. Serum total thyroxine levels were measured in 195 euthyroid subjects and it was established that normal values lay within the range 57 to 155 nmol/1. Serial blood samples taken over a 24-hour period, from 11 subjects, indicated that there was no circadian rhythm so that samples for total thyroxine assay can be taken at any time of the day. Similar results were obtained using serum or plasma. Satisfactory results were obtained for three quality control sera when measured by seven different laboratories using this method. PMID:932232

  16. Electronic test and calibration circuits, a compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A wide variety of simple test calibration circuits are compiled for the engineer and laboratory technician. The majority of circuits were found inexpensive to assemble. Testing electronic devices and components, instrument and system test, calibration and reference circuits, and simple test procedures are presented.

  17. Measuring the Transition Temperature of a Superconductor in a Pre-University Laboratory

    ERIC Educational Resources Information Center

    Ireson, Gren

    2006-01-01

    This article presents the methodology and results for a simple approach to the measurement of the transition temperature of a superconducting material, in a pre-university laboratory session, using readily available apparatus (and some liquid nitrogen).

  18. The Computer as Lab Partner.

    ERIC Educational Resources Information Center

    Nicklin, R. C.

    1985-01-01

    Microcomputers can record laboratory measurements which human laboratory partners can never collect. Simple, harder, and general-purpose interfaces are discussed, with suggestions for several experiments involving an exercise bike, acceleration, and pendulums. Additional applications with pH meters, spectrophotometers, and chromatographs are also…

  19. The Gabriel Synthesis of Benzylamine

    ERIC Educational Resources Information Center

    Nigh, W. G.

    1975-01-01

    Describes an undergraduate organic chemistry laboratory experiment which utilizes the Gabriel Synthesis to demonstrate the acidity of imides and to provide an example of nucleophilic substitution reactions. The experiment also demonstrates the laboratory techniques involved in simple and steam distillation, filtration, extraction, and…

  20. Integration of ANFIS, NN and GA to determine core porosity and permeability from conventional well log data

    NASA Astrophysics Data System (ADS)

    Ja'fari, Ahmad; Hamidzadeh Moghadam, Rasoul

    2012-10-01

    Routine core analysis provides useful information for petrophysical study of the hydrocarbon reservoirs. Effective porosity and fluid conductivity (permeability) could be obtained from core analysis in laboratory. Coring hydrocarbon bearing intervals and analysis of obtained cores in laboratory is expensive and time consuming. In this study an improved method to make a quantitative correlation between porosity and permeability obtained from core and conventional well log data by integration of different artificial intelligent systems is proposed. The proposed method combines the results of adaptive neuro-fuzzy inference system (ANFIS) and neural network (NN) algorithms for overall estimation of core data from conventional well log data. These methods multiply the output of each algorithm with a weight factor. Simple averaging and weighted averaging were used for determining the weight factors. In the weighted averaging method the genetic algorithm (GA) is used to determine the weight factors. The overall algorithm was applied in one of SW Iran’s oil fields with two cored wells. One-third of all data were used as the test dataset and the rest of them were used for training the networks. Results show that the output of the GA averaging method provided the best mean square error and also the best correlation coefficient with real core data.

  1. Proof of concept of a simple computer-assisted technique for correcting bone deformities.

    PubMed

    Ma, Burton; Simpson, Amber L; Ellis, Randy E

    2007-01-01

    We propose a computer-assisted technique for correcting bone deformities using the Ilizarov method. Our technique is an improvement over prior art in that it does not require a tracking system, navigation hardware and software, or intraoperative registration. Instead, we rely on a postoperative CT scan to obtain all of the information necessary to plan the correction and compute a correction schedule for the patient. Our laboratory experiments using plastic phantoms produced deformity corrections accurate to within 3.0 degrees of rotation and 1 mm of lengthening.

  2. A comparative study of the novel spectrophotometric methods versus conventional ones for the simultaneous determination of Esomeprazole magnesium trihydrate and Naproxen in their binary mixture.

    PubMed

    Lotfy, Hayam M; Amer, Sawsan M; Zaazaa, Hala E; Mostafa, Noha S

    2015-01-01

    Two novel simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed and validated for simultaneous determination of Esomeprazole magnesium trihydrate (ESO) and Naproxen (NAP) namely; absorbance subtraction and ratio difference. The results were compared to that of the conventional spectrophotometric methods namely; dual wavelength and isoabsorptive point coupled with first derivative of ratio spectra and derivative ratio. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for determination of ESO and NAP in their laboratory prepared mixtures and pharmaceutical preparation. No preliminary separation steps are required for the proposed spectrophotometeric procedures. The statistical comparison showed that there is no significant difference between the proposed methods and the reported method with respect to both accuracy and precision. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Novel spectrophotometric determination of flumethasone pivalate and clioquinol in their binary mixture and pharmaceutical formulation.

    PubMed

    Abdel-Aleem, Eglal A; Hegazy, Maha A; Sayed, Nour W; Abdelkawy, M; Abdelfatah, Rehab M

    2015-02-05

    This work is concerned with development and validation of three simple, specific, accurate and precise spectrophotometric methods for determination of flumethasone pivalate (FP) and clioquinol (CL) in their binary mixture and ear drops. Method A is a ratio subtraction spectrophotometric one (RSM). Method B is a ratio difference spectrophotometric one (RDSM), while method C is a mean center spectrophotometric one (MCR). The calibration curves are linear over the concentration range of 3-45 μg/mL for FP, and 2-25 μg/mL for CL. The specificity of the developed methods was assessed by analyzing different laboratory prepared mixtures of the FP and CL. The three methods were validated as per ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide.

    PubMed

    Darwish, Hany W; Hassan, Said A; Salem, Maissa Y; El-Zeany, Badr A

    2013-09-01

    Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Teaching Population Growth Using Cultures of Vinegar Eels, "Turbatrix aceti" (Nematoda)

    ERIC Educational Resources Information Center

    Wallace, Robert L.

    2005-01-01

    A simple laboratory exercise is presented that follows the population growth of the common vinegar eel, "Turbatrix aceti" (Nematoda), in a microcosm using a simple culture medium. It lends itself to an exercise in a single semester course. (Contains 4 figures.)

  6. Mechanical Resonance of a Plastic Strip.

    ERIC Educational Resources Information Center

    Ayers, R. Dean

    1981-01-01

    Presents an experiment to illustrate mechanical resonance designed for use in lower division laboratories. The apparatus and procedure have been kept simple. The basic experiment yields measurements of amplitude versus driving frequency, but a fairly simple elaboration allows for measurements of phase lag as well. (Author/SK)

  7. Understanding Exponential Growth: As Simple as a Drop in a Bucket.

    ERIC Educational Resources Information Center

    Goldberg, Fred; Shuman, James

    1984-01-01

    Provides procedures for a simple laboratory activity on exponential growth and its characteristic doubling time. The equipment needed consists of a large plastic bucket, an eyedropper, a stopwatch, an assortment of containers and graduated cylinders, and a supply of water. (JN)

  8. Utilizing the virus-induced blocking of apoptosis in an easy baculovirus titration method

    PubMed Central

    Niarchos, Athanasios; Lagoumintzis, George; Poulas, Konstantinos

    2015-01-01

    Baculovirus-mediated protein expression is a robust experimental technique for producing recombinant higher-eukaryotic proteins because it combines high yields with considerable post-translational modification capabilities. In this expression system, the determination of the titer of recombinant baculovirus stocks is important to achieve the correct multiplicity of infection for effective amplification of the virus and high expression of the target protein. To overcome the drawbacks of existing titration methods (e.g., plaque assay, real-time PCR), we present a simple and reliable assay that uses the ability of baculoviruses to block apoptosis in their host cells to accurately titrate virus samples. Briefly, after incubation with serial dilutions of baculovirus samples, Sf9 cells were UV irradiated and, after apoptosis induction, they were viewed via microscopy; the presence of cluster(s) of infected cells as islets indicated blocked apoptosis. Subsequently, baculovirus titers were calculated through the determination of the 50% endpoint dilution. The method is simple, inexpensive, and does not require unique laboratory equipment, consumables or expertise; moreover, it is versatile enough to be adapted for the titration of every virus species that can block apoptosis in any culturable host cells which undergo apoptosis under specific conditions. PMID:26490731

  9. A simple method for the evaluation of microfluidic architecture using flow quantitation via a multiplexed fluidic resistance measurement.

    PubMed

    Leslie, Daniel C; Melnikoff, Brett A; Marchiarullo, Daniel J; Cash, Devin R; Ferrance, Jerome P; Landers, James P

    2010-08-07

    Quality control of microdevices adds significant costs, in time and money, to any fabrication process. A simple, rapid quantitative method for the post-fabrication characterization of microchannel architecture using the measurement of flow with volumes relevant to microfluidics is presented. By measuring the mass of a dye solution passed through the device, it circumvents traditional gravimetric and interface-tracking methods that suffer from variable evaporation rates and the increased error associated with smaller volumes. The multiplexed fluidic resistance (MFR) measurement method measures flow via stable visible-wavelength dyes, a standard spectrophotometer and common laboratory glassware. Individual dyes are used as molecular markers of flow for individual channels, and in channel architectures where multiple channels terminate at a common reservoir, spectral deconvolution reveals the individual flow contributions. On-chip, this method was found to maintain accurate flow measurement at lower flow rates than the gravimetric approach. Multiple dyes are shown to allow for independent measurement of multiple flows on the same device simultaneously. We demonstrate that this technique is applicable for measuring the fluidic resistance, which is dependent on channel dimensions, in four fluidically connected channels simultaneously, ultimately determining that one chip was partially collapsed and, therefore, unusable for its intended purpose. This method is thus shown to be widely useful in troubleshooting microfluidic flow characteristics.

  10. An Experiment Using Sucrose Density Gradients in the Undergraduate Biochemistry Laboratory.

    ERIC Educational Resources Information Center

    Turchi, Sandra L.; Weiss, Monica

    1988-01-01

    Describes an experiment to be performed in an undergraduate biochemistry laboratory that is based on a gradient centrifugation system employing a simple bench top centrifuge, a freezer, and frozen surcose gradient solution to separate macromolecules and subcellular components. (CW)

  11. Classical and novel pharmacological insights offered by the simple chick cardiomyocyte cell culture model: a valuable teaching aid and a primer for "real" research.

    PubMed

    Freestone, N S; Sam, C L S

    2017-03-01

    The chick embryo cardiomyocyte model of cell culture is a staple technique in many physiology and pharmacology laboratories. Despite the relative simplicity, robustness, and reproducibility inherent in this model, it can be used in a variety of ways to yield important new insights that help facilitate student understanding of underlying physiological and pharmacological concepts as well as, more generally, the scientific method. Using this model, this paper will show real data obtained by undergraduate students in the authors' laboratories. It will first demonstrate classical pharmacological concepts such as full and partial agonism, inverse agonism, and competitive reversible antagonism and then move on to more complex pharmacology involving the characterization of novel receptors in these cells. Copyright © 2017 the American Physiological Society.

  12. CONTROL OF STREPTOCOCCAL THROAT INFECTIONS IN SCHOOLS—A Cooperative Program Followed in Orange County

    PubMed Central

    Russell, Edward Lee

    1956-01-01

    Attempts to identify streptococcal throat infections on clinical evidence alone do not provide an adequate or reliable index of the prevalence of these infections in the community. Epidemiologic information on streptococcal throat infections based on bacteriological identification permits a more accurate assessment of the situation and more logical and more effective control measures. Recent refinements in laboratory procedures have provided a simple, reliable and relatively inexpensive method for the identification of Group A beta hemolytic streptococci by public health or clinical laboratories. In Orange County a program for the identification of streptococcal throat infections by cooperative action of the medical profession, the health department and the school authorities greatly aided in control of the disease. A voluntary health agency (heart association) made an important contribution toward the success of the control program. PMID:13374555

  13. Development of a simple, rapid, and robust intrathecal catheterization method in the rat.

    PubMed

    Mazur, Curt; Fitzsimmons, Bethany; Kamme, Fredrik; Nichols, Brandon; Powers, Berit; Wancewicz, Ed

    2017-03-15

    The blood brain barrier (BBB) is an impediment to the development of large and highly charged molecules as therapeutics for diseases and injuries of the central nervous system (CNS). Antisense oligonucleotides (ASOs) are large (6000-8000MW) and highly charged and therefore do not cross the BBB. A method of circumventing the blood brain barrier to test ASOs, and other non-BBB penetrant molecules, as CNS therapeutics is the direct administration of these molecules to the CNS tissue or cerebral spinal fluid. We developed a rapid, simple and robust method for the intrathecal catheterization of rats to test putatively therapeutic antisense oligonucleotides. This method utilizes 23-gauge needles, simply constructed ½in. long 19-gauge guide cannulas and 8cm long plastic PE-10 sized catheters. Unlike the cisterna magna approach, this method uses a lumbar approach for intrathecal catheterization with the catheter residing entirely in the cauda equina space minimizing spinal cord compression. Readily available materials and only a few specialized pieces of equipment, which are easily manufactured, are used for this intrathecal catheterization method. This method is easy to learn and has been taught to multiple in house surgeons, collaborators and contract laboratories. Greater than 90% catheterization success is routinely achieved with this method and as many as 100 catheters can be placed and test substance administered in one 6-h period. This method has allowed the pre-clinical testing of hundreds of ASOs as therapeutics for CNS indications. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Determination of dapsone in serum and saliva using reversed-phase high-performance liquid chromatography with ultraviolet or electrochemical detection.

    PubMed

    Moncrieff, J

    1994-03-18

    A simple, extractionless method for the determination of dapsone in serum and saliva is described. Reversed-phase high-performance liquid chromatography is used with UV detection at 295 nm or electrochemical detection at 0.7 V. Diazoxide in buffer is the internal standard for UV detection and practolol for electrochemical detection. Sample preparation is minimal with protein precipitation of serum samples whilst saliva samples are simply diluted with addition of an internal standard. Low-level serum and saliva samples are front-cut on-line with a 3 cm laboratory-made precolumn in the loop position on a standard Valco injection valve. Isocratic separation is achieved on a 250 mm x 4.6 mm I.D. stainless-steel Spherisorb S5 ODS-1 column. The mobile phase for high levels of dapsone is acetonitrile-elution buffer (12:88, v/v) at 2 ml/min and a column temperature of 40 degrees C for both serum and saliva separations. For the low-level assays using electrochemical detection and solid-phase clean-up, the mobile phase is acetonitrile-methanol-elution buffer (9:4:87, v/v/v). The UV and electrochemical detection limits are 25 ng/ml and 200 pg/ml, respectively, in both serum and saliva. This simple method is applicable to the routine monitoring of dapsone levels in serum from leprotic patients and electrochemical detection gives a simple, reliable method for the monitoring of trough values in subjects on anti-malarial prophylaxis.

  15. Evaluation of a Simple in-House Test to Presumptively Differentiate Mycobacterium tuberculosis Complex from Nontuberculous Mycobacteria by Detection of p-Nitrobenzoic Acid Metabolites

    PubMed Central

    Wang, Guirong; Yu, Xia; Liang, Qian; Chen, Suting; Wilson, Stuart; Huang, Hairong

    2013-01-01

    The timely differentiation of Mycobacterium tuberculosis complex (MTC) and non-tubercular mycobacterium (NTM) species is urgently needed in patient care since the routine laboratory method is time consuming and cumbersome. An easy and cheap method which can successfully distinguish MTC from NTM was established and evaluated. 38 mycobacterial type and reference strains and 65 clinical isolates representing 10 species of mycobacterium were included in this study. Metabolites of p-nitrobenzoic acid (PNB) reduction were identified using liquid chromatography and tandem mass spectrometry (LC/MS/MS). A spectrophotometric method was developed to detect these metabolites, which was evaluated on a number of MTC and NTM species. All of the tested NTM species and strains reduced PNB to p-aminobenzoic acid (PABA), while none of the MTC strains showed a similar activity. Spectrophotometric detection of PABA had 100% sensitivity and specificity for MTC and NTM differentiation among the type strains and the clinical isolates tested. PABA was identified as one of the metabolites of PNB reduction. All the tested NTM species metabolized PNB to PABA whereas the MTC members lacked this activity. A simple, specific and cost-effective method based on PABA production was established in order to discriminate MTC from NTM from cultured organisms. PMID:24260497

  16. A simple micro-photometric method for urinary iodine determination.

    PubMed

    Grimm, Gabriele; Lindorfer, Heidelinde; Kieweg, Heidi; Marculescu, Rodrig; Hoffmann, Martha; Gessl, Alois; Sager, Manfred; Bieglmayer, Christian

    2011-10-01

    Urinary iodide concentration (UIC) is useful to evaluate nutritional iodine status. In clinical settings UIC helps to exclude blocking of the thyroid gland by excessive endogenous iodine, if diagnostic or therapeutic administration of radio-iodine is indicated. Therefore, this study established a simple test for the measurement of UIC. UIC was analyzed in urine samples of 200 patients. Samples were pre-treated at 95°C for 45 min with ammonium persulfate in a thermal cycler, followed by a photometric Sandell-Kolthoff reaction (SK) carried out in microtiter plates. For method comparison, UIC was analyzed in 30 samples by inductivity coupled plasma mass spectro-metry (ICP-MS) as a reference method. Incubation conditions were optimized concerning recovery. The photometric test correlated well to the reference method (SK=0.91*ICP-MS+1, r=0.962) and presented with a functional sensitivity of 20 μg/L. UIC of patient samples ranged from <20 to 750 μg/L (median 110 μg/L); 90% of the urine samples had iodide concentrations below 210 μg/L. The modified SK-test takes approximately 90 min for analyses of 20 urine samples compared with 27 h for ICP-MS. The photometric test provides satisfactory results and can be performed with the basic equipment of a clinical laboratory.

  17. Simple Demonstration of the Seebeck Effect

    ERIC Educational Resources Information Center

    Molki, Arman

    2010-01-01

    In this article we propose a simple and low-cost experimental set-up through which science educators can demonstrate the Seebeck effect using a thermocouple and an instrumentation amplifier. The experiment can be set up and conducted during a 1-hour laboratory session. (Contains 3 tables and 3 figures.)

  18. Experimental Control of Simple Pendulum Model

    ERIC Educational Resources Information Center

    Medina, C.

    2004-01-01

    This paper conveys information about a Physics laboratory experiment for students with some theoretical knowledge about oscillatory motion. Students construct a simple pendulum that behaves as an ideal one, and analyze model assumption incidence on its period. The following aspects are quantitatively analyzed: vanishing friction, small amplitude,…

  19. Jacks--A Study of Simple Machines.

    ERIC Educational Resources Information Center

    Parsons, Ralph

    This vocational physics individualized student instructional module on jacks (simple machines used to lift heavy objects) contains student prerequisites and objectives, an introduction, and sections on the ratchet bumper jack, the hydraulic jack, the screw jack, and load limitations. Designed with a laboratory orientation, each section consists of…

  20. A Progression of Static Equilibrium Laboratory Exercises

    ERIC Educational Resources Information Center

    Kutzner, Mickey; Kutzner, Andrew

    2013-01-01

    Although simple architectural structures like bridges, catwalks, cantilevers, and Stonehenge have been integral in human societies for millennia, as have levers and other simple tools, modern students of introductory physics continue to grapple with Newton's conditions for static equilibrium. As formulated in typical introductory physics…

  1. Voltammetry at the Thin-Film Mercury Electrode (TFME).

    ERIC Educational Resources Information Center

    Pomeroy, R. S.; And Others

    1989-01-01

    Reviewed is the use of the Thin-Film Mercury Electrode for anodic stripping voltammetry, simple voltammetry of solution cations and cathodic stripping voltammetry for the determination of an environmentally important molecule, thiourea. The construction of a simple potentiostat and applications for student laboratory courses are included. (CW)

  2. ShareSync: A Solution for Deterministic Data Sharing over Ethernet

    NASA Technical Reports Server (NTRS)

    Dunn, Daniel J., II; Koons, William A.; Kennedy, Richard D.; Davis, Philip A.

    2007-01-01

    As part of upgrading the Contact Dynamics Simulation Laboratory (CDSL) at the NASA Marshall Space Flight Center (MSFC), a simple, cost effective method was needed to communicate data among the networked simulation machines and I/O controllers used to run the facility. To fill this need and similar applicable situations, a generic protocol was developed, called ShareSync. ShareSync is a lightweight, real-time, publish-subscribe Ethernet protocol for simple and deterministic data sharing across diverse machines and operating systems. ShareSync provides a simple Application Programming Interface (API) for simulation programmers to incorporate into their code. The protocol is compatible with virtually all Ethernet-capable machines, is flexible enough to support a variety of applications, is fast enough to provide soft real-time determinism, and is a low-cost resource for distributed simulation development, deployment, and maintenance. The first design cycle iteration of ShareSync has been completed, and the protocol has undergone several testing procedures including endurance and benchmarking tests and approaches the 2001ts data synchronization design goal for the CDSL.

  3. Online automatic tuning and control for fed-batch cultivation

    PubMed Central

    van Straten, Gerrit; van der Pol, Leo A.; van Boxtel, Anton J. B.

    2007-01-01

    Performance of controllers applied in biotechnological production is often below expectation. Online automatic tuning has the capability to improve control performance by adjusting control parameters. This work presents automatic tuning approaches for model reference specific growth rate control during fed-batch cultivation. The approaches are direct methods that use the error between observed specific growth rate and its set point; systematic perturbations of the cultivation are not necessary. Two automatic tuning methods proved to be efficient, in which the adaptation rate is based on a combination of the error, squared error and integral error. These methods are relatively simple and robust against disturbances, parameter uncertainties, and initialization errors. Application of the specific growth rate controller yields a stable system. The controller and automatic tuning methods are qualified by simulations and laboratory experiments with Bordetella pertussis. PMID:18157554

  4. A Simple and Useful Method to Apply Exogenous NO Gas to Plant Systems: Bell Pepper Fruits as a Model.

    PubMed

    Palma, José M; Ruiz, Carmelo; Corpas, Francisco J

    2018-01-01

    Nitric oxide (NO) is involved many physiological plant processes, including germination, growth and development of roots, flower setting and development, senescence, and fruit ripening. In the latter physiological process, NO has been reported to play an opposite role to ethylene. Thus, treatment of fruits with NO may lead to delay ripening independently of whether they are climacteric or nonclimacteric. In many cases different methods have been reported to apply NO to plant systems involving sodium nitroprusside, NONOates, DETANO, or GSNO to investigate physiological and molecular consequences. In this chapter a method to treat plant materials with NO is provided using bell pepper fruits as a model. This method is cheap, free of side effects, and easy to apply since it only requires common chemicals and tools available in any biology laboratory.

  5. Simple Experiments in Psychology.

    ERIC Educational Resources Information Center

    Ray, Wilbert S.

    This material, developed for use in secondary schools, is a programmed-type learning package consisting of an "Instructor's Manual", a "Student's Introduction", and a "Laboratory Manual". The general goal of the program is to teach students to distinguish between reliable and unreliable information. The "Laboratory Manual" contains nine simple…

  6. The Pond Is Our Laboratory

    ERIC Educational Resources Information Center

    Marchewka, Barbara Turco

    1978-01-01

    This science teacher's laboratory is a pond within walking distance of his school that provides a stimulating environment for exploring the natural world. With simple materials students practice making careful observations, taking measurements and compiling and graphing information for their science studies. They also extend their pond experiences…

  7. Working with Enzymes - Where Is Lactose Digested? An Enzyme Assay for Nutritional Biochemistry Laboratories

    NASA Astrophysics Data System (ADS)

    Pope, Sandi R.; Tolleson, Tonya D.; Williams, R. Jill; Underhill, Russell D.; Deal, S. Todd

    1998-06-01

    At Georgia Southern University, we offer a sophomore-level introductory biochemistry course that is aimed at nutrition and chemistry education majors. The laboratory portion of this course has long lacked an experimental introduction to enzymes. We have developed a simple enzyme assay utilizing lactase enzyme from crushed LactAid tablets and a 5% lactose solution ("synthetic milk"). In the experiment, the students assay the activity of the enzyme on the "synthetic milk" at pHs of approximately 1, 6, and 8 with the stated goal of determining where lactose functions in the digestive tract. The activity of the lactase may be followed chromatographically or spectrophotometrically. The experiment, which is actually a simple pH assay, is easily implemented in allied health chemistry laboratory courses and readily lends itself to adaptation for more complex kinetic assays in upper-level biochemistry laboratory courses. The experimental details, including a list of required supplies and hints for implementation, are provided.

  8. Development of a simple and rapid method for the specific identification of organism causing anthrax by slide latex agglutination.

    PubMed

    Sumithra, T G; Chaturvedi, V K; Gupta, P K; Sunita, S C; Rai, A K; Kutty, M V H; Laxmi, U; Murugan, M S

    2014-05-01

    A specific latex agglutination test (LAT) based on anti-PA (protective antigen) antibodies having detection limit of 5 × 10(4) formalin treated Bacillus anthracis cells or 110 ng of PA was optimized in this study. The optimized LAT could detect anthrax toxin in whole blood as well as in serum from the animal models of anthrax infection. The protocol is a simple and promising method for the specific detection of bacteria causing anthrax under routine laboratory, as well as in field, conditions without any special equipments or expertise. The article presents the first report of a latex agglutination test for the specific identification of the cultures of bacteria causing anthrax. As the test is targeting one of anthrax toxic protein (PA), this can also be used to determine virulence of suspected organisms. At the same time, the same LAT can be used directly on whole blood or sera samples under field conditions for the specific diagnosis of anthrax. © 2013 The Society for Applied Microbiology.

  9. A Simple and Effective Mass Spectrometric Approach to Identify the Adulteration of the Mediterranean Diet Component Extra-Virgin Olive Oil with Corn Oil.

    PubMed

    Di Girolamo, Francesco; Masotti, Andrea; Lante, Isabella; Scapaticci, Margherita; Calvano, Cosima Damiana; Zambonin, Carlo; Muraca, Maurizio; Putignani, Lorenza

    2015-09-01

    Extra virgin olive oil (EVOO) with its nutraceutical characteristics substantially contributes as a major nutrient to the health benefit of the Mediterranean diet. Unfortunately, the adulteration of EVOO with less expensive oils (e.g., peanut and corn oils), has become one of the biggest source of agricultural fraud in the European Union, with important health implications for consumers, mainly due to the introduction of seed oil-derived allergens causing, especially in children, severe food allergy phenomena. In this regard, revealing adulterations of EVOO is of fundamental importance for health care and prevention reasons, especially in children. To this aim, effective analytical methods to assess EVOO purity are necessary. Here, we propose a simple, rapid, robust and very sensitive method for non-specialized mass spectrometric laboratory, based on the matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) coupled to unsupervised hierarchical clustering (UHC), principal component (PCA) and Pearson's correlation analyses, to reveal corn oil (CO) adulterations in EVOO at very low levels (down to 0.5%).

  10. A Simple and Effective Mass Spectrometric Approach to Identify the Adulteration of the Mediterranean Diet Component Extra-Virgin Olive Oil with Corn Oil

    PubMed Central

    Di Girolamo, Francesco; Masotti, Andrea; Lante, Isabella; Scapaticci, Margherita; Calvano, Cosima Damiana; Zambonin, Carlo; Muraca, Maurizio; Putignani, Lorenza

    2015-01-01

    Extra virgin olive oil (EVOO) with its nutraceutical characteristics substantially contributes as a major nutrient to the health benefit of the Mediterranean diet. Unfortunately, the adulteration of EVOO with less expensive oils (e.g., peanut and corn oils), has become one of the biggest source of agricultural fraud in the European Union, with important health implications for consumers, mainly due to the introduction of seed oil-derived allergens causing, especially in children, severe food allergy phenomena. In this regard, revealing adulterations of EVOO is of fundamental importance for health care and prevention reasons, especially in children. To this aim, effective analytical methods to assess EVOO purity are necessary. Here, we propose a simple, rapid, robust and very sensitive method for non-specialized mass spectrometric laboratory, based on the matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) coupled to unsupervised hierarchical clustering (UHC), principal component (PCA) and Pearson’s correlation analyses, to reveal corn oil (CO) adulterations in EVOO at very low levels (down to 0.5%). PMID:26340625

  11. Validation of the ANSR Listeria method for detection of Listeria spp. in environmental samples.

    PubMed

    Wendorf, Michael; Feldpausch, Emily; Pinkava, Lisa; Luplow, Karen; Hosking, Edan; Norton, Paul; Biswas, Preetha; Mozola, Mark; Rice, Jennifer

    2013-01-01

    ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.

  12. Evaluation of analytical performance based on partial order methodology.

    PubMed

    Carlsen, Lars; Bruggemann, Rainer; Kenessova, Olga; Erzhigitov, Erkin

    2015-01-01

    Classical measurements of performances are typically based on linear scales. However, in analytical chemistry a simple scale may be not sufficient to analyze the analytical performance appropriately. Here partial order methodology can be helpful. Within the context described here, partial order analysis can be seen as an ordinal analysis of data matrices, especially to simplify the relative comparisons of objects due to their data profile (the ordered set of values an object have). Hence, partial order methodology offers a unique possibility to evaluate analytical performance. In the present data as, e.g., provided by the laboratories through interlaboratory comparisons or proficiency testings is used as an illustrative example. However, the presented scheme is likewise applicable for comparison of analytical methods or simply as a tool for optimization of an analytical method. The methodology can be applied without presumptions or pretreatment of the analytical data provided in order to evaluate the analytical performance taking into account all indicators simultaneously and thus elucidating a "distance" from the true value. In the present illustrative example it is assumed that the laboratories analyze a given sample several times and subsequently report the mean value, the standard deviation and the skewness, which simultaneously are used for the evaluation of the analytical performance. The analyses lead to information concerning (1) a partial ordering of the laboratories, subsequently, (2) a "distance" to the Reference laboratory and (3) a classification due to the concept of "peculiar points". Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Tight-binding study of stacking fault energies and the Rice criterion of ductility in the fcc metals

    NASA Astrophysics Data System (ADS)

    Mehl, Michael J.; Papaconstantopoulos, Dimitrios A.; Kioussis, Nicholas; Herbranson, M.

    2000-02-01

    We have used the Naval Research Laboratory (NRL) tight-binding (TB) method to calculate the generalized stacking fault energy and the Rice ductility criterion in the fcc metals Al, Cu, Rh, Pd, Ag, Ir, Pt, Au, and Pb. The method works well for all classes of metals, i.e., simple metals, noble metals, and transition metals. We compared our results with full potential linear-muffin-tin orbital and embedded atom method (EAM) calculations, as well as experiment, and found good agreement. This is impressive, since the NRL-TB approach only fits to first-principles full-potential linearized augmented plane-wave equations of state and band structures for cubic systems. Comparable accuracy with EAM potentials can be achieved only by fitting to the stacking fault energy.

  14. INHALATION TOXICOLOGY METHODS: The Generation and Characterization of Exposure Atmospheres and Inhalational Exposures

    PubMed Central

    Chen, Lung-Chi; Lippmann, Morton

    2015-01-01

    In this review, we outline the need for laboratory-based inhalation toxicology studies, the historical background on adverse health effects of airborne toxicants, and the benefits of advance planning for the building of analytic options into the study design to maximize the scientific gains to be derived from the investments in the study. We then discuss methods for: 1) the generation and characterization of exposure atmospheres for inhalation exposures in humans and laboratory animals; 2) their delivery and distribution into and within whole-body exposure chambers, head-only exposure chambers, face-masks, and mouthpieces or nasal catheters; 3) options for on-line functional assays during and between exposures; and 4) options for serial non-invasive assays of response. In doing so, we go beyond exposures to single agents and simple mixtures, and include methods for evaluating biological responses to complex environmental mixtures. We also emphasize that great care should be taken in the design and execution of such studies so that the scientific returns can be maximized both initially, and in follow-up utilization of archived samples of the exposure atmospheres, excreta, and tissues collected for histology. PMID:25645246

  15. Dual-domain mass-transfer parameters from electrical hysteresis: theory and analytical approach applied to laboratory, synthetic streambed, and groundwater experiments

    USGS Publications Warehouse

    Briggs, Martin A.; Day-Lewis, Frederick D.; Ong, John B.; Harvey, Judson W.; Lane, John W.

    2014-01-01

    Models of dual-domain mass transfer (DDMT) are used to explain anomalous aquifer transport behavior such as the slow release of contamination and solute tracer tailing. Traditional tracer experiments to characterize DDMT are performed at the flow path scale (meters), which inherently incorporates heterogeneous exchange processes; hence, estimated “effective” parameters are sensitive to experimental design (i.e., duration and injection velocity). Recently, electrical geophysical methods have been used to aid in the inference of DDMT parameters because, unlike traditional fluid sampling, electrical methods can directly sense less-mobile solute dynamics and can target specific points along subsurface flow paths. Here we propose an analytical framework for graphical parameter inference based on a simple petrophysical model explaining the hysteretic relation between measurements of bulk and fluid conductivity arising in the presence of DDMT at the local scale. Analysis is graphical and involves visual inspection of hysteresis patterns to (1) determine the size of paired mobile and less-mobile porosities and (2) identify the exchange rate coefficient through simple curve fitting. We demonstrate the approach using laboratory column experimental data, synthetic streambed experimental data, and field tracer-test data. Results from the analytical approach compare favorably with results from calibration of numerical models and also independent measurements of mobile and less-mobile porosity. We show that localized electrical hysteresis patterns resulting from diffusive exchange are independent of injection velocity, indicating that repeatable parameters can be extracted under varied experimental designs, and these parameters represent the true intrinsic properties of specific volumes of porous media of aquifers and hyporheic zones.

  16. Dual-domain mass-transfer parameters from electrical hysteresis: Theory and analytical approach applied to laboratory, synthetic streambed, and groundwater experiments

    NASA Astrophysics Data System (ADS)

    Briggs, Martin A.; Day-Lewis, Frederick D.; Ong, John B.; Harvey, Judson W.; Lane, John W.

    2014-10-01

    Models of dual-domain mass transfer (DDMT) are used to explain anomalous aquifer transport behavior such as the slow release of contamination and solute tracer tailing. Traditional tracer experiments to characterize DDMT are performed at the flow path scale (meters), which inherently incorporates heterogeneous exchange processes; hence, estimated "effective" parameters are sensitive to experimental design (i.e., duration and injection velocity). Recently, electrical geophysical methods have been used to aid in the inference of DDMT parameters because, unlike traditional fluid sampling, electrical methods can directly sense less-mobile solute dynamics and can target specific points along subsurface flow paths. Here we propose an analytical framework for graphical parameter inference based on a simple petrophysical model explaining the hysteretic relation between measurements of bulk and fluid conductivity arising in the presence of DDMT at the local scale. Analysis is graphical and involves visual inspection of hysteresis patterns to (1) determine the size of paired mobile and less-mobile porosities and (2) identify the exchange rate coefficient through simple curve fitting. We demonstrate the approach using laboratory column experimental data, synthetic streambed experimental data, and field tracer-test data. Results from the analytical approach compare favorably with results from calibration of numerical models and also independent measurements of mobile and less-mobile porosity. We show that localized electrical hysteresis patterns resulting from diffusive exchange are independent of injection velocity, indicating that repeatable parameters can be extracted under varied experimental designs, and these parameters represent the true intrinsic properties of specific volumes of porous media of aquifers and hyporheic zones.

  17. Laboratory data manipulation tools basic data handling programs. Volume 2: Detailed software/hardware documentation

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The set of computer programs described allows for data definition, data input, and data transfer between the LSI-11 microcomputers and the VAX-11/780 minicomputer. Program VAXCOM allows for a simple method of textual file transfer from the LSI to the VAX. Program LSICOM allows for easy file transfer from the VAX to the LSI. Program TTY changes the LSI-11 operators console to the LSI's printing device. Program DICTIN provides a means for defining a data set for input to either computer. Program DATAIN is a simple to operate data entry program which is capable of building data files on either machine. Program LEDITV is an extremely powerful, easy to use, line oriented text editor. Program COPYSBF is designed to print out textual files on the line printer without character loss from FORTRAN carriage control or wide record transfer.

  18. Addressing of LnCaP Cell Using Magnetic Particles Assisted Impedimetric Microelectrode.

    PubMed

    Nguyen, Dung Thi Xuan; Tran, Trong Binh; Nguyen, Phuong-Diem; Min, Junhong

    2016-03-01

    In this study, we provide a facile, effective technique for a simple isolation and enrichment of low metastatic prostate tumor cell LNCaP using biocompatible, magnetic particles asissted impedimetric sensing system. Hydrophobic cell membrane anchors (BAM) were generated onto magnetic particles which diameters vary from 50 nm to 5 μm and were used to capture LNCaP cells from the suspension. Finally, magnetic particle-LNCaP complex were addressed onto the surface of the interdigitated microelectrode (IDM). Cell viability was monitored by our laboratory developed-technique Electrical Cell Substrate Impedance Sensing (ECIS). The results reavealed that 50 nm-magnetic particles showed best performance in terms of cell separation and cell viability. This technique provides a simple and efficient method for the direct addressing of LNCaP cell on the surface and enhances better understanding of cell behavior for cancer management in the near future.

  19. Cognitive tests predict real-world errors: the relationship between drug name confusion rates in laboratory-based memory and perception tests and corresponding error rates in large pharmacy chains

    PubMed Central

    Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L

    2017-01-01

    Background Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. Objectives We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Methods Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Results Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Conclusions Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. PMID:27193033

  20. Teaching Sustainability Analysis in Electrical Engineering Lab Courses

    ERIC Educational Resources Information Center

    Braun, D.

    2010-01-01

    Laboratory courses represent an incompletely tapped opportunity to teach sustainability concepts. This work introduces and evaluates a simple strategy used to teach sustainability concepts in electrical engineering laboratory courses. The technique would readily adapt to other disciplines. The paper presents assessment data and a wiki containing…

  1. Impact Crater Experiments for Introductory Physics and Astronomy Laboratories

    ERIC Educational Resources Information Center

    Claycomb, J. R.

    2009-01-01

    Activity-based collisional analysis is developed for introductory physics and astronomy laboratory experiments. Crushable floral foam is used to investigate the physics of projectiles undergoing completely inelastic collisions with a low-density solid forming impact craters. Simple drop experiments enable determination of the average acceleration,…

  2. Survey of Biochemical Separation Techniques

    ERIC Educational Resources Information Center

    Nilsson, Melanie R.

    2007-01-01

    A simple laboratory exercise is illustrated that exposes students to wide range of separation techniques in one laboratory program and provides a nice complement to a project-oriented program. Students have learned the basic principles of syringe filtration, centricon, dialysis, gel filtration and solid-phase extraction methodologies and have got…

  3. Incorporating Basic Optical Microscopy in the Instrumental Analysis Laboratory

    ERIC Educational Resources Information Center

    Flowers, Paul A.

    2011-01-01

    A simple and versatile approach to incorporating basic optical microscopy in the undergraduate instrumental analysis laboratory is described. Attaching a miniature CCD spectrometer to the video port of a standard compound microscope yields a visible microspectrophotometer suitable for student investigations of fundamental spectrometry concepts,…

  4. Dendropedagogy: Teaching Botany, Ecology and Statistical Principles through Tree-Ring Studies.

    ERIC Educational Resources Information Center

    Rubino, Darrin L.; McCarthy, Brian C.

    2002-01-01

    Develops a simple tree-ring laboratory to demonstrate the basics of dendrochronology. Provides two upper-level laboratory exercises primarily intended to demonstrate the specific dendrochronology subdisciplines of dendroclimatology and dendroecology. Suggests using the exercises separately or in unison as part of a multidisciplinary capstone…

  5. Opportunities for Improved Serodiagnosis of Human Tuberculosis, Bovine Tuberculosis, and Paratuberculosis

    PubMed Central

    Wadhwa, Ashutosh; Hickling, Graham J.; Eda, Shigetoshi

    2012-01-01

    Mycobacterial infections—tuberculosis (TB), bovine tuberculosis (bTB), and Johne's disease (JD)—are major infectious diseases of both human and animals. Methods presently in use for diagnosis of mycobacterial infections include bacterial culture, nucleic acid amplification, tuberculin skin test, interferon-γ assay, and serology. Serological tests have several advantages over other methods, including short turn-around time, relatively simple procedures, and low cost. However, current serodiagnostic methods for TB, bTB and JD exhibit low sensitivity and/or specificity. Recent studies that have aimed to develop improved serodiagnostic tests have mostly focused on identifying useful species-specific protein antigens. A review of recent attempts to improve diagnostic test performance indicates that the use of multiple antigens can improve the accuracy of serodiagnosis of these mycobacterial diseases. Mycobacteria also produce a variety of species-specific nonprotein molecules; however, only a few such molecules (e.g., cord factor and lipoarabinomannan) have so far been evaluated for their effectiveness as diagnostic antigens. For TB and bTB, there has been recent progress in developing laboratory-free diagnostic methods. New technologies such as microfluidics and “Lab-on-Chip” are examples of promising new technologies that can underpin development of laboratory-free diagnostic devices for these mycobacterial infections. PMID:22720192

  6. Simultaneous determination of sulfonamides, penicillins and coccidiostats in pork by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nebot, C; Regal, P; Miranda, J; Cepeda, A; Fente, C

    2012-05-01

    Veterinary drugs are widely and legally used to treat and prevent disease in livestock. However, drugs are also used illegally as growth-promoting agents. To protect the health of consumers, maximum residue limits (MRL) in food of animal origin have been established and are listed in Regulation 37/2010. According to this regulation, more than 300 drugs need to be controlled regularly in laboratories for residues of veterinary drugs. A cost-effective analytical method is very important and explains why the development of multi-residual methods is becoming popular in laboratories. The aim of this work is to describe a simple, rapid and economical high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous identification and quantification of 21 veterinary drugs in pork muscle samples. The sample clean-up procedure is performed with acidified dichloromethane and does not require solid phase extraction. The method is applicable to nine sulfonamides and seven coccidiostats identified within 36 min. Calculated relevant validation parameters such as recoveries (from 72.to 126 %), intra-precision and intermediate precision (relative standard deviation below 40 %) and decision limits (below 7 µg Kg(-1)) were within acceptable range and in compliance with the requirements of Commission Decision 2002/657/EC. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  7. Rapid detection of potyviruses from crude plant extracts.

    PubMed

    Silva, Gonçalo; Oyekanmi, Joshua; Nkere, Chukwuemeka K; Bömer, Moritz; Kumar, P Lava; Seal, Susan E

    2018-04-01

    Potyviruses (genus Potyvirus; family Potyviridae) are widely distributed and represent one of the most economically important genera of plant viruses. Therefore, their accurate detection is a key factor in developing efficient control strategies. However, this can sometimes be problematic particularly in plant species containing high amounts of polysaccharides and polyphenols such as yam (Dioscorea spp.). Here, we report the development of a reliable, rapid and cost-effective detection method for the two most important potyviruses infecting yam based on reverse transcription-recombinase polymerase amplification (RT-RPA). The developed method, named 'Direct RT-RPA', detects each target virus directly from plant leaf extracts prepared with a simple and inexpensive extraction method avoiding laborious extraction of high-quality RNA. Direct RT-RPA enables the detection of virus-positive samples in under 30 min at a single low operation temperature (37 °C) without the need for any expensive instrumentation. The Direct RT-RPA tests constitute robust, accurate, sensitive and quick methods for detection of potyviruses from recalcitrant plant species. The minimal sample preparation requirements and the possibility of storing RPA reagents without cold chain storage, allow Direct RT-RPA to be adopted in minimally equipped laboratories and with potential use in plant clinic laboratories and seed certification facilities worldwide. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Indirect spectrophotometric determination of sodium ceftriaxone with n-propyl alcohol-ammonium sulfate-water system by extraction flotation of copper(II).

    PubMed

    Zhao, Wei; Zhang, Yan; Li, Quanmin

    2008-05-01

    Although the determination methods of sodium ceftriaxone has been increasingly reported, these methods have their inherent limits preventing them from being broadly applied in common laboratories. In order to circumvent this problem, a rapid and simple method for the indirect spectrophotometric determination of sodium ceftriaxone is reported. Sodium ceftriaxone was degraded completely in the presence of 0.20 mol/l sodium hydroxide in boiling water bath for 20 min. The thiol group (-SH) of the degradation product (I) of sodium ceftriaxone could reduce cupric to cuprous ions, and the resulting which was precipitated with the thiol group (-SH) of the degradation product (II) at pH 4.0. By determining the residual amount of copper (II), the indirect determination of sodium ceftriaxone can be achieved. Standard curve of sodium ceftriaxone versus the flotation yield of copper(II) showed that sodium ceftriaxone could be determined in low concentrations. The linear range of sodium ceftriaxone was 0.70-32 microg/ml and the detection limit evaluated by calibration curve (3sigma/k) was found to be 0.60 microg/ml. A simple and efficient method was developed and it has been successfully applied to the determination of sodium ceftriaxone in human serum and urine samples, respectively. It is expected that this method will find broad applications in the detection of cephalosporin derivatives with similar structure.

  9. A simple method to equalize the workload when operating several small wastewater treatment plants: a case study.

    PubMed

    De Feo, G; De Gisi, S; Galasso, M

    2013-01-01

    The aim of the present study is to define a simple (and easy to use) method to equalize the workload of personnel operating several small wastewater treatment plants (SWWTPs). The approach is illustrated through a case study which is the result of collaboration between researchers and a water and wastewater management company operating in Southern Italy. The topic is important since personnel have a significant impact on the operating costs of SWWTPs, and the approach outlined results in the minimum number of staff being required to assure the management of the service. Four kinds of work units are considered: plant managers, assistant plant managers, laboratory technicians and executives. In order to develop a practical, feasible and easy to use method, the workload was evaluated considering only the population equivalent (PE) and the number of plants managed. The core of the method is the evaluation of the percentage of time that the personnel units devote to the operation of SWWTPs of the municipality considered. The proposed procedure offers a useful tool to equalize the workload, both in terms of PE and the number of plants managed, the procedure being easily modifiable to introduce other evaluation criteria. By using familiar concepts such as PE and number of plants managed, the approach of the method can easily be understood by management. It can also be readily adapted to other similar situations.

  10. Quantification of the methylation status of the PWS/AS imprinted region: comparison of two approaches based on bisulfite sequencing and methylation-sensitive MLPA.

    PubMed

    Dikow, Nicola; Nygren, Anders Oh; Schouten, Jan P; Hartmann, Carolin; Krämer, Nikola; Janssen, Bart; Zschocke, Johannes

    2007-06-01

    Standard methods used for genomic methylation analysis allow the detection of complete absence of either methylated or non-methylated alleles but are usually unable to detect changes in the proportion of methylated and unmethylated alleles. We compare two methods for quantitative methylation analysis, using the chromosome 15q11-q13 imprinted region as model. Absence of the non-methylated paternal allele in this region leads to Prader-Willi syndrome (PWS) whilst absence of the methylated maternal allele results in Angelman syndrome (AS). A proportion of AS is caused by mosaic imprinting defects which may be missed with standard methods and require quantitative analysis for their detection. Sequence-based quantitative methylation analysis (SeQMA) involves quantitative comparison of peaks generated through sequencing reactions after bisulfite treatment. It is simple, cost-effective and can be easily established for a large number of genes. However, our results support previous suggestions that methods based on bisulfite treatment may be problematic for exact quantification of methylation status. Methylation-specific multiplex ligation-dependent probe amplification (MS-MLPA) avoids bisulfite treatment. It detects changes in both CpG methylation as well as copy number of up to 40 chromosomal sequences in one simple reaction. Once established in a laboratory setting, the method is more accurate, reliable and less time consuming.

  11. A sensitive method for the determination of Sulfonamides in seawater samples by Solid Phase Extraction and UV-Visible spectrophotometry

    NASA Astrophysics Data System (ADS)

    Errayess, Sophia Ait; Lahcen, Abdellatif Ait; Idrissi, Laila; Marcoaldi, Caterina; Chiavarini, Salvatore; Amine, Aziz

    2017-06-01

    The authors have developed a sensitive spectrophotometric method for determination of sulfonamide derivatives such as sulfanilamide (SAA), sulfadiazine (SDZ), sulfacetamide (SCT) sulfamethoxazole (SMX), sulfamerazine (SMR), sulfadimethoxine (SDX), sulfamethiazole (SMT) and Sulfathiazole (STZ). This method is based on the Bratton-Marshall reaction, which involves the diazotization of sulfonamides with sodium nitrite under acidic conditions, followed by coupling with N-(1-naphtyl) ethylenediamine dihydrochloride (NED) to form a pink colored compound. Therefore, the Bratton-Marshall method was modified by optimizing the reaction conditions, which allows us to determine a low concentration range of sulfonamides compared to the reported methods. The limits of detection and quantification obtained were 0.019-0.05 and 0.06-0.16 μg mL- 1, respectively. In comparison with other reported methods using different coupling agents, the proposed method was found to be the most simple and sensitive for sulfonamides determination. In this paper, the modified method was successfully employed for the determination of sulfonamides in drinking water, seawater and pharmaceutical and veterinary formulations. The purpose of this work is to optimize and develop a simple method for extraction and concentration of sulfonamides present as residues in seawater and their quantification with the recommended spectrophotometric method. Solid phase extraction (SPE) of sulfonamides from seawater samples was evaluated using Oasis HLB cartridges (3 mL, 540 mg). The recovery efficiency was investigated in the sulfonamides concentration range comprised between 0.19 and 126 ng mL- 1. The ease of use of this extraction method makes it very useful for routine laboratory work.

  12. Optimized protocols for Mycobacterium leprae strain management: frozen stock preservation and maintenance in athymic nude mice.

    PubMed

    Trombone, Ana Paula Fávaro; Pedrini, Sílvia Cristina Barbosa; Diório, Suzana Madeira; Belone, Andréa de Faria Fernandes; Fachin, Luciana Raquel Vicenzi; do Nascimento, Dejair Caitano; Rosa, Patricia Sammarco

    2014-03-23

    Leprosy, caused by Mycobacterium leprae, is an important infectious disease that is still endemic in many countries around the world, including Brazil. There are currently no known methods for growing M. leprae in vitro, presenting a major obstacle in the study of this pathogen in the laboratory. Therefore, the maintenance and growth of M. leprae strains are preferably performed in athymic nude mice (NU-Foxn1(nu)). The laboratory conditions for using mice are readily available, easy to perform, and allow standardization and development of protocols for achieving reproducible results. In the present report, we describe a simple protocol for purification of bacilli from nude mouse footpads using trypsin, which yields a suspension with minimum cell debris and with high bacterial viability index, as determined by fluorescent microscopy. A modification to the standard method for bacillary counting by Ziehl-Neelsen staining and light microscopy is also demonstrated. Additionally, we describe a protocol for freezing and thawing bacillary stocks as an alternative protocol for maintenance and storage of M. leprae strains.

  13. Organization and ELISA-Based Results of the First Proficiency Testing to Evaluate the Ability of European Union Laboratories to Detect Staphylococcal Enterotoxin Type B (SEB) in Buffer and Milk

    PubMed Central

    Nia, Yacine; Rodriguez, Mélanie; Zeleny, Reinhard; Herbin, Sabine; Auvray, Frédéric; Fiebig, Uwe; Avondet, Marc-André; Munoz, Amalia; Hennekinne, Jacques-Antoine

    2016-01-01

    The aim of this work was to organize the first proficiency test (PT) dedicated to staphylococcal enterotoxin B (SEB) detection in milk and buffer solutions. This paper describes the organization of the PT trial according to EN ISO 17043 requirements. Characterization of the SEB stock solution was performed using SDS-PAGE and SE-specific ELISA, and amino acid analysis was used to assign its protein concentration. The solution was then used to prepare six PT materials (four milk and two buffer batches) at a ng/g toxin level, which included one blank and one SEA-containing milk as specificity control. Suitable material homogeneity and stability were assessed using screening and quantitative ELISAs. Among the methods used by the participants, ELISA-based methods demonstrated their efficiency for the detection of SEB in both simple and complex matrices. The results serve as a basis for further improving the detection capabilities in expert laboratories and can therefore be considered as a contribution to biopreparedness. PMID:27649244

  14. Indomethacin nanocrystals prepared by different laboratory scale methods: effect on crystalline form and dissolution behavior

    NASA Astrophysics Data System (ADS)

    Martena, Valentina; Censi, Roberta; Hoti, Ela; Malaj, Ledjan; Di Martino, Piera

    2012-12-01

    The objective of this study is to select very simple and well-known laboratory scale methods able to reduce particle size of indomethacin until the nanometric scale. The effect on the crystalline form and the dissolution behavior of the different samples was deliberately evaluated in absence of any surfactants as stabilizers. Nanocrystals of indomethacin (native crystals are in the γ form) (IDM) were obtained by three laboratory scale methods: A (Batch A: crystallization by solvent evaporation in a nano-spray dryer), B (Batch B-15 and B-30: wet milling and lyophilization), and C (Batch C-20-N and C-40-N: Cryo-milling in the presence of liquid nitrogen). Nanocrystals obtained by the method A (Batch A) crystallized into a mixture of α and γ polymorphic forms. IDM obtained by the two other methods remained in the γ form and a different attitude to the crystallinity decrease were observed, with a more considerable decrease in crystalline degree for IDM milled for 40 min in the presence of liquid nitrogen. The intrinsic dissolution rate (IDR) revealed a higher dissolution rate for Batches A and C-40-N, due to the higher IDR of α form than γ form for the Batch A, and the lower crystallinity degree for both the Batches A and C-40-N. These factors, as well as the decrease in particle size, influenced the IDM dissolution rate from the particle samples. Modifications in the solid physical state that may occur using different particle size reduction treatments have to be taken into consideration during the scale up and industrial development of new solid dosage forms.

  15. Simple and robust diagnosis of early, small and AFP-negative primary hepatic carcinomas: an integrative approach of serum fluorescence and conventional blood tests.

    PubMed

    Wang, Ting; Zhang, Kun-He; Hu, Piao-Ping; Huang, Zeng-Yong; Zhang, Pan; Wan, Qin-Si; Huang, De-Qiang; Lv, Nong-Hua

    2016-09-27

    The diagnosis of early, small and alpha-fetoprotein (AFP)-negative primary hepatic carcinomas (PHCs) remains a significant challenge. We developed a simple and robust approach to noninvasively detect these PHCs. A rapid, high-throughput and single-tube method was firstly developed to measure serum autofluorescence and cell-free DNA (cfDNA)-related fluorescence using a real-time PCR system, and both types of serum fluorescence were measured and routine laboratory data were collected in 1229 subjects, including 353 PHC patients, 331 liver cirrhosis (LC) patients, 213 chronic hepatitis (CH) patients and 332 normal controls (NC). The results showed that fluorescence indicators of PHC differed from those of NC, CH and LC to various extents, and all of them were not associated with age, gender, or AFP level. The logistic regression models established with the fluorescence indicators alone and combined with AFP, hepatic function tests and blood cell analyses were valuable for distinguishing early, small, AFP-negative and all PHC from LC, CH, NC and all non-PHC, with areas under the receiver operating characteristic curves 0.857-0.993 and diagnostic accuracies 80.2-97.7%. Conclusively, serum autofluorescence and cfDNA-related fluorescence are able to be rapidly and simultaneously measured by our simple method and valuable for diagnosing early, small and AFP-negative PHCs, especially integrating with AFP and conventional blood tests.

  16. Simple and rapid system for two-dimensional gel electrophoresis technique: A laboratory exercise for high school students.

    PubMed

    Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay

    2018-02-28

    Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky laboratory equipments. Practical courses of biochemistry at high school or undergraduate levels are often affected by these complications. Two dimensional gel electrophoresis technique (2D-PAGE) used for resolving thousands of proteins in a gel is a combination of isoelectric focusing (first dimension gel electrophoresis technique) and sodium-dodecylsulphate PAGE (second dimension gel electrophoresis technique or SDS-PAGE). Two different laboratory equipments are needed to carry out effective 2D-PAGE technique, which also invites extra burden to the school laboratory. Here, we describe a low cost, time saving and simple gel cassette for protein 2D-PAGE technique that uses easily fabricated components and routine off-the-shelf materials. The performance of the apparatus was verified in a practical exercise by a group of high school students with positive outcomes. © 2018 by The International Union of Biochemistry and Molecular Biology, 2018. © 2018 The International Union of Biochemistry and Molecular Biology.

  17. Mass Spectrometry for the Masses

    ERIC Educational Resources Information Center

    Persinger, Jared D.; Hoops, Geoffrey, C.; Samide, Michael J.

    2004-01-01

    A simple, qualitative experiment is developed for implementation, where the gas chromatography-mass spectrometry (GC-MS) plays an important role, into the laboratory curriculum of a chemistry course designed for nonscience majors. This laboratory experiment is well suited for the students as it helps them to determine the validity of their…

  18. Waterless Condensers for the Teaching Laboratory: An Adaptation of Traditional Glassware

    ERIC Educational Resources Information Center

    Baum, Erich W.; Esteb, John J.; Wilson, Anne M.

    2014-01-01

    A simple adaptation of traditional "chemistry kit" condensers for the organic chemistry teaching laboratory is described. These waterless condensers have been employed safely with most solvents. They can be easily fabricated, stored, and used in the same manner as water-cooled condensers. These condensers were utilized in several…

  19. A Unit Cell Laboratory Experiment: Marbles, Magnets, and Stacking Arrangements

    ERIC Educational Resources Information Center

    Collins, David C.

    2011-01-01

    An undergraduate first-semester general chemistry laboratory experiment introducing face-centered, body-centered, and simple cubic unit cells is presented. Emphasis is placed on the stacking arrangement of solid spheres used to produce a particular unit cell. Marbles and spherical magnets are employed to prepare each stacking arrangement. Packing…

  20. Colorimetric Quantification and in Situ Detection of Collagen

    ERIC Educational Resources Information Center

    Esteban, Francisco J.; del Moral, Maria L.; Sanchez-Lopez, Ana M.; Blanco, Santos; Jimenez, Ana; Hernandez, Raquel; Pedrosa, Juan A.; Peinado, Maria A.

    2005-01-01

    A simple multidisciplinary and inexpensive laboratory exercise is proposed, in which the undergraduate student may correlate biochemical and anatomical findings. The entire practical session can be completed in one 2.5-3 hour laboratory period, and consists of the quantification of collagen and total protein content from tissue sections--without…

  1. A Laboratory Demonstration Illustrating Bioseparations Using Colorful Proteins

    ERIC Educational Resources Information Center

    Cohen, Theodore M.; Rohs, Amanda E.; Lefebvre, Brian G.

    2008-01-01

    A simple in class laboratory illustrating the principles of ion exchange chromatography as a bioseparation technique is described. A protein's isoelectric point as a driving force for ion exchange chromatography is easily demonstrated by using combinations of proteins with natural color or fluorescence, such as DsRed2, enhanced green fluorescent…

  2. ORGANIC CONTAMINANT DISTRIBUTION IN SEDIMENTS, POLYCHAETES (NEREIS VIRENS) AND THE AMERICAN LOBSTER, HOMARUS AMERICANUS IN A LABORATORY FOOD CHAIN EXPERIMENT

    EPA Science Inventory

    A laboratory experiment was conducted to investigate the transfer of organic contaminants from an environmentally contaminated marine sediment through a simple marine food chain. The infaunal polychaete, Nereis virens, was exposed to contaminated sediment collected from the Passa...

  3. Simple Laboratory Exercise for Induction of Beta-Mannanase from "Aspergillus niger"

    ERIC Educational Resources Information Center

    Mulimani, V. H.; Naganagouda, K.

    2010-01-01

    This laboratory experiment was designed for Biochemistry, Biotechnology, Microbiology, and Food Technology students of undergraduate and postgraduate courses. The experiment shows the advantages of using agricultural waste, copra mannan as potent inducer of [beta]-mannanase. The students were able to compare the enzyme induction by commercial…

  4. A Novel Laboratory Activity for Teaching about the Evolution of Multicellularity

    ERIC Educational Resources Information Center

    Ratcliff, William C.; Raney, Allison; Westreich, Sam; Cotner, Sehoya

    2014-01-01

    The evolution of complexity remains one of the most challenging topics in biology to teach effectively. We present a novel laboratory activity, modeled on a recent experimental breakthrough, in which students experimentally evolve simple multicellularity using single-celled yeast ("Saccharomyces cerevisiae"). By simply selecting for…

  5. A Simple Photochemical Experiment for the Advanced Laboratory.

    ERIC Educational Resources Information Center

    Rosenfeld, Stuart M.

    1986-01-01

    Describes an experiment to provide students with: (1) an introduction to photochemical techniques and theory; (2) an experience with semimicro techniques; (3) an application of carbon-14 nuclear magnetic resonance; and (4) a laboratory with some qualities of a genuine experiment. These criteria are met in the photooxidation of 9,…

  6. A New Application for Radioimmunoassay: Measurement of Thermodynamic Constants.

    ERIC Educational Resources Information Center

    Angstadt, Carol N.; And Others

    1983-01-01

    Describes a laboratory experiment in which an equilibrium radioimmunoassay (RIA) is used to estimate thermodynamic parameters such as equilibrium constants. The experiment is simple and inexpensive, and it introduces a technique that is important in the clinical chemistry and research laboratory. Background information, procedures, and results are…

  7. Laboratory diagnosis of peritonitis in patients on continuous ambulatory peritoneal dialysis.

    PubMed Central

    Ludlam, H A; Price, T N; Berry, A J; Phillips, I

    1988-01-01

    The clinical course and laboratory diagnosis of peritonitis in patients undergoing continuous ambulatory peritoneal dialysis was studied in 32 consecutive episodes. Peritonitis was associated with a failure in aseptic technique in eight episodes and with an exit-site infection in four episodes. Intraperitoneal vancomycin and ceftazidime were safe, effective, and convenient. Most patients administered their antibiotics at home, and symptoms usually resolved by day 4. Culture of the deposit obtained by centrifugation of 50 ml of effluent after leukocyte lysis provided the best rate of recovery (84% culture positive) but was technically demanding. Filtration of the same volume without leukocyte lysis was simple to perform and almost as effective. Enrichment was less satisfactory (65% culture positive) owing to the presence of antibiotic or infection with fastidious microorganisms. Culture of 50 ml of effluent after concentration by a commonly used laboratory technique, centrifugation without leukocyte lysis, performed poorly (59% culture positive at 48 h), as this method caused sequestration and death of microorganisms within the leukocytes. Culture of nearly 1 liter of effluent from 33 asymptomatic patients by the same techniques yielded no microorganisms. PMID:3183023

  8. Application of solid-phase microextraction for in vivo laboratory and field sampling of pharmaceuticals in fish.

    PubMed

    Zhou, Simon Ningsun; Oakes, Ken D; Servos, Mark R; Pawliszyn, Janusz

    2008-08-15

    Previous field studies utilizing solid-phase microextraction (SPME) predominantly focused on volatile and semivolatile compounds in air or water. Earlier in vivo sampling studies utilizing SPME were limited to the liquid matrix (blood). The present study has expanded the SPME technique to semisolid tissues under laboratory and field conditions through the investigation of both theoretical and applied experimental approaches. Pre-equilibrium extraction and desorption were performed in vivo in two separate animals. Excellent linearity was found between the amounts extracted by SPME from the muscle of living fish and the waterborne concentrations of pharmaceuticals. A simple SPME method is also described to simultaneously determine free and total analyte concentrations in living tissue. The utility of in vivo SPME sampling was evaluated in wild fish collected from a number of different river locations under varying degrees of influence from municipal wastewater effluents. Diphenhydramine and diltiazem were detected in the muscle of fish downstream of a local wastewater treatment plant. Based on this study, SPME demonstrated several important advantages such as simplicity, sensitivity, and robustness under laboratory and in vivo field sampling conditions.

  9. Quantity quotient reporting. A proposal for a standardized presentation of laboratory results.

    PubMed

    Haeckel, Rainer; Wosniok, Werner

    2009-01-01

    Laboratory results are reported in different units (despite international recommendations for SI units) together with different reference limits, of which several exist for many quantities. It is proposed to adopt the concept of the intelligence quotient and to report quantitative results as a quantity quotient (QQ) in laboratory medicine. This quotient is essentially the difference (measured result minus mean or mode value of the reference interval) divided by the observed biological variation CV(o). Thus, all quantities are reported in the same unit system with the same reference limits (for convenience shifted to e.g., 80-120). The critical difference can also be included in this standardization concept. In this way the information of reference intervals and the original result are integrated into one combined value, which has the same format for all quantities suited for quotient reporting (QR). The proposal of QR does not interfere with neither the current concepts of traceability, SI units or method standardization. This proposal represents a further step towards harmonization of reporting. It provides simple values which can be interpreted easily by physicians and their patients.

  10. Development of a simple indocyanine green measurement method using an automated biochemical analyser.

    PubMed

    Sato, Yuka; Seimiya, Masanori; Yoshida, Toshihiko; Sawabe, Yuji; Hokazono, Eisaku; Osawa, Susumu; Matsushita, Kazuyuki

    2017-01-01

    Background The indocyanine green retention rate is important for assessing the severity of liver disorders. In the conventional method, blood needs to be collected twice. In the present study, we developed an automated indocyanine green method that does not require blood sampling before intravenous indocyanine green injections and is applicable to an automated biochemical analyser. Methods The serum samples of 471 patients collected before and after intravenous indocyanine green injections and submitted to the clinical laboratory of our hospital were used as samples. The standard procedure established by the Japan Society of Hepatology was used as the standard method. In the automated indocyanine green method, serum collected after an intravenous indocyanine green injection was mixed with the saline reagent containing a surfactant, and the indocyanine green concentration was measured at a dominant wavelength of 805 nm and a complementary wavelength of 884 nm. Results The coefficient of variations of the within- and between-run reproducibilities of this method were 2% or lower, and dilution linearity passing the origin was noted up to 10 mg/L indocyanine green. The reagent was stable for four weeks or longer. Haemoglobin, bilirubin and chyle had no impact on the results obtained. The correlation coefficient between the standard method (x) and this method (y) was r=0.995; however, slight divergence was noted in turbid samples. Conclusion Divergence in turbid samples may have corresponded to false negativity with the standard procedure. Our method may be highly practical because blood sampling before indocyanine green loading is unnecessary and measurements are simple.

  11. Measurements for 8 common analytes in native sera identify inadequate standardization among 6 routine laboratory assays.

    PubMed

    Stepman, Hedwig C M; Tiikkainen, Ulla; Stöckl, Dietmar; Vesper, Hubert W; Edwards, Selvin H; Laitinen, Harri; Pelanti, Jonna; Thienpont, Linda M

    2014-06-01

    External quality assessment (EQA) with commutable samples is essential for assessing the quality of assays performed by laboratories, particularly when the emphasis is on their standardization status and interchangeability of results. We used a panel of 20 fresh-frozen single-donation serum samples to assess assays for the measurement of creatinine, glucose, phosphate, uric acid, total cholesterol, HDL cholesterol, LDL cholesterol, and triglycerides. The commercial random access platforms included: Abbott Architect, Beckman Coulter AU, Ortho Vitros, Roche Cobas, Siemens Advia, and Thermo Scientific Konelab. The assessment was done at the peer group level and by comparison against the all-method trimmed mean or reference method values, where available. The considered quality indicators were intraassay imprecision, combined imprecision (including sample-matrix interference), bias, and total error. Fail/pass decisions were based on limits reflecting state-of-the-art performance, but also limits related to biological variation. Most assays showed excellent peer performance attributes, except for HDL- and LDL cholesterol. Cases in which individual assays had biases exceeding the used limits were the Siemens Advia creatinine (-4.2%), Ortho Vitros phosphate (8.9%), Beckman Coulter AU triglycerides (5.4%), and Thermo Scientific Konelab uric acid (6.4%), which lead to considerable interassay discrepancies. Additionally, large laboratory effects were observed that caused interlaboratory differences of >30%. The design of the EQA study was well suited for monitoring different quality attributes of assays performed in daily laboratory practice. There is a need for improvement, even for simple clinical chemistry analytes. In particular, the interchangeability of results remains jeopardized both by assay standardization issues and individual laboratory effects. © 2014 The American Association for Clinical Chemistry.

  12. Improving Histopathology Laboratory Productivity: Process Consultancy and A3 Problem Solving.

    PubMed

    Yörükoğlu, Kutsal; Özer, Erdener; Alptekin, Birsen; Öcal, Cem

    2017-01-01

    The ISO 17020 quality program has been run in our pathology laboratory for four years to establish an action plan for correction and prevention of identified errors. In this study, we aimed to evaluate the errors that we could not identify through ISO 17020 and/or solve by means of process consulting. Process consulting is carefully intervening in a group or team to help it to accomplish its goals. The A3 problem solving process was run under the leadership of a 'workflow, IT and consultancy manager'. An action team was established consisting of technical staff. A root cause analysis was applied for target conditions, and the 6-S method was implemented for solution proposals. Applicable proposals were activated and the results were rated by six-sigma analysis. Non-applicable proposals were reported to the laboratory administrator. A mislabelling error was the most complained issue triggering all pre-analytical errors. There were 21 non-value added steps grouped in 8 main targets on the fish bone graphic (transporting, recording, moving, individual, waiting, over-processing, over-transaction and errors). Unnecessary redundant requests, missing slides, archiving issues, redundant activities, and mislabelling errors were proposed to be solved by improving visibility and fixing spaghetti problems. Spatial re-organization, organizational marking, re-defining some operations, and labeling activities raised the six sigma score from 24% to 68% for all phases. Operational transactions such as implementation of a pathology laboratory system was suggested for long-term improvement. Laboratory management is a complex process. Quality control is an effective method to improve productivity. Systematic checking in a quality program may not always find and/or solve the problems. External observation may reveal crucial indicators about the system failures providing very simple solutions.

  13. Using the failure mode and effects analysis model to improve parathyroid hormone and adrenocorticotropic hormone testing

    PubMed Central

    Magnezi, Racheli; Hemi, Asaf; Hemi, Rina

    2016-01-01

    Background Risk management in health care systems applies to all hospital employees and directors as they deal with human life and emergency routines. There is a constant need to decrease risk and increase patient safety in the hospital environment. The purpose of this article is to review the laboratory testing procedures for parathyroid hormone and adrenocorticotropic hormone (which are characterized by short half-lives) and to track failure modes and risks, and offer solutions to prevent them. During a routine quality improvement review at the Endocrine Laboratory in Tel Hashomer Hospital, we discovered these tests are frequently repeated unnecessarily due to multiple failures. The repetition of the tests inconveniences patients and leads to extra work for the laboratory and logistics personnel as well as the nurses and doctors who have to perform many tasks with limited resources. Methods A team of eight staff members accompanied by the Head of the Endocrine Laboratory formed the team for analysis. The failure mode and effects analysis model (FMEA) was used to analyze the laboratory testing procedure and was designed to simplify the process steps and indicate and rank possible failures. Results A total of 23 failure modes were found within the process, 19 of which were ranked by level of severity. The FMEA model prioritizes failures by their risk priority number (RPN). For example, the most serious failure was the delay after the samples were collected from the department (RPN =226.1). Conclusion This model helped us to visualize the process in a simple way. After analyzing the information, solutions were proposed to prevent failures, and a method to completely avoid the top four problems was also developed. PMID:27980440

  14. Laboratory investigation on the role of tubular shaped micro resonators phononic crystal insertion on the absorption coefficient of profiled sound absorber

    NASA Astrophysics Data System (ADS)

    Yahya, I.; Kusuma, J. I.; Harjana; Kristiani, R.; Hanina, R.

    2016-02-01

    This paper emphasizes the influence of tubular shaped microresonators phononic crystal insertion on the sound absorption coefficient of profiled sound absorber. A simple cubic and two different bodies centered cubic phononic crystal lattice model were analyzed in a laboratory test procedure. The experiment was conducted by using transfer function based two microphone impedance tube method refer to ASTM E-1050-98. The results show that sound absorption coefficient increase significantly at the mid and high-frequency band (600 - 700 Hz) and (1 - 1.6 kHz) when tubular shaped microresonator phononic crystal inserted into the tested sound absorber element. The increment phenomena related to multi-resonance effect that occurs when sound waves propagate through the phononic crystal lattice model that produce multiple reflections and scattering in mid and high-frequency band which increases the sound absorption coefficient accordingly

  15. Acoustic impulse response method as a source of undergraduate research projects and advanced laboratory experiments.

    PubMed

    Robertson, W M; Parker, J M

    2012-03-01

    A straightforward and inexpensive implementation of acoustic impulse response measurement is described utilizing the signal processing technique of coherent averaging. The technique is capable of high signal-to-noise measurements with personal computer data acquisition equipment, an amplifier/speaker, and a high quality microphone. When coupled with simple waveguide test systems fabricated from commercial PVC plumbing pipe, impulse response measurement has proven to be ideal for undergraduate research projects-often of publishable quality-or for advanced laboratory experiments. The technique provides important learning objectives for science or engineering students in areas such as interfacing and computer control of experiments; analog-to-digital conversion and sampling; time and frequency analysis using Fourier transforms; signal processing; and insight into a variety of current research areas such as acoustic bandgap materials, acoustic metamaterials, and fast and slow wave manipulation. © 2012 Acoustical Society of America

  16. AIR SCORE ASSESSMENT FOR ACUTE APPENDICITIS

    PubMed Central

    VON-MÜHLEN, Bruno; FRANZON, Orli; BEDUSCHI, Murilo Gamba; KRUEL, Nicolau; LUPSELO, Daniel

    2015-01-01

    Background: Acute appendicitis is the most common cause of acute abdomen. Approximately 7% of the population will be affected by this condition during full life. The development of AIR score may contribute to diagnosis associating easy clinical criteria and two simple laboratory tests. Aim: To evaluate the score AIR (Appendicitis Inflammatory Response score) as a tool for the diagnosis and prediction of severity of acute appendicitis. Method: Were evaluated all patients undergoing surgical appendectomy. From 273 patients, 126 were excluded due to exclusion criteria. All patients were submitted o AIR score. Results: The value of the C-reactive protein and the percentage of leukocytes segmented blood count showed a direct relationship with the phase of acute appendicitis. Conclusion: As for the laboratory criteria, serum C-reactive protein and assessment of the percentage of the polymorphonuclear leukocytes count were important to diagnosis and disease stratification. PMID:26537139

  17. Enzymatic production of single-molecule FISH and RNA capture probes.

    PubMed

    Gaspar, Imre; Wippich, Frank; Ephrussi, Anne

    2017-10-01

    Arrays of singly labeled short oligonucleotides that hybridize to a specific target revolutionized RNA biology, enabling quantitative, single-molecule microscopy analysis and high-efficiency RNA/RNP capture. Here, we describe a simple and efficient method that allows flexible functionalization of inexpensive DNA oligonucleotides by different fluorescent dyes or biotin using terminal deoxynucleotidyl transferase and custom-made functional group conjugated dideoxy-UTP. We show that (i) all steps of the oligonucleotide labeling-including conjugation, enzymatic synthesis, and product purification-can be performed in a standard biology laboratory, (ii) the process yields >90%, often >95% labeled product with minimal carryover of impurities, and (iii) the oligonucleotides can be labeled with different dyes or biotin, allowing single-molecule FISH, RNA affinity purification, and Northern blot analysis to be performed. © 2017 Gaspar et al.; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  18. Advantages of combined touch screen technology and text hyperlink for the pathology grossing manual: a simple approach to access instructive information in biohazardous environments.

    PubMed

    Qu, Zhenhong; Ghorbani, Rhonda P; Li, Hongyan; Hunter, Robert L; Hannah, Christina D

    2007-03-01

    Gross examination, encompassing description, dissection, and sampling, is a complex task and an essential component of surgical pathology. Because of the complexity of the task, standardized protocols to guide the gross examination often become a bulky manual that is difficult to use. This problem is further compounded by the high specimen volume and biohazardous nature of the task. As a result, such a manual is often underused, leading to errors that are potentially harmful and time consuming to correct-a common chronic problem affecting many pathology laboratories. To combat this problem, we have developed a simple method that incorporates complex text and graphic information of a typical procedure manual and yet allows easy access to any intended instructive information in the manual. The method uses the Object-Linking-and-Embedding function of Microsoft Word (Microsoft, Redmond, WA) to establish hyperlinks among different contents, and then it uses the touch screen technology to facilitate navigation through the manual on a computer screen installed at the cutting bench with no need for a physical keyboard or a mouse. It takes less than 4 seconds to reach any intended information in the manual by 3 to 4 touches on the screen. A 3-year follow-up study shows that this method has increased use of the manual and has improved the quality of gross examination. The method is simple and can be easily tailored to different formats of instructive information, allowing flexible organization, easy access, and quick navigation. Increased compliance to instructive information reduces errors at the grossing bench and improves work efficiency.

  19. The Ins and Outs of Breath Holding: Simple Demonstrations of Complex Respiratory Physiology

    ERIC Educational Resources Information Center

    Skow, Rachel J.; Day, Trevor A.; Fuller, Jonathan E.; Bruce, Christina D.; Steinback, Craig D.

    2015-01-01

    The physiology of breath holding is complex, and voluntary breath-hold duration is affected by many factors, including practice, psychology, respiratory chemoreflexes, and lung stretch. In this activity, we outline a number of simple laboratory activities or classroom demonstrations that illustrate the complexity of the integrative physiology…

  20. 25+ Years of the Hubble Space Telescope and a Simple Error That Cost Millions

    ERIC Educational Resources Information Center

    Shakerin, Said

    2016-01-01

    A simple mistake in properly setting up a measuring device caused millions of dollars to be spent in correcting the initial optical failure of the Hubble Space Telescope (HST). This short article is intended as a lesson for a physics laboratory and discussion of errors in measurement.

  1. A Simple Molecular Dynamics Lab to Calculate Viscosity as a Function of Temperature

    ERIC Educational Resources Information Center

    Eckler, Logan H.; Nee, Matthew J.

    2016-01-01

    A simple molecular dynamics experiment is described to demonstrate transport properties for the undergraduate physical chemistry laboratory. The AMBER package is used to monitor self-diffusion in "n"-hexane. Scripts (available in the Supporting Information) make the process considerably easier for students, allowing them to focus on the…

  2. Pasta production: complexity in defining processing conditions for reference trials and quality assessment models

    USDA-ARS?s Scientific Manuscript database

    Pasta is a simple food made from water and durum wheat (Triticum turgidum subsp. durum) semolina. As pasta increases in popularity, studies have endeavored to analyze the attributes that contribute to high quality pasta. Despite being a simple food, the laboratory scale analysis of pasta quality is ...

  3. Measuring the speed of light with baryon acoustic oscillations.

    PubMed

    Salzano, Vincenzo; Dąbrowski, Mariusz P; Lazkoz, Ruth

    2015-03-13

    In this Letter, we describe a new method to use baryon acoustic oscillations (BAO) to derive a constraint on the possible variation of the speed of light. The method relies on the fact that there is a simple relation between the angular diameter distance (D(A)) maximum and the Hubble function (H) evaluated at the same maximum-condition redshift, which includes speed of light c. We note the close analogy of the BAO probe with a laboratory experiment: here we have D(A) which plays the role of a standard (cosmological) ruler, and H^{-1}, with the dimension of time, as a (cosmological) clock. We evaluate if current or future missions such as Euclid can be sensitive enough to detect any variation of c.

  4. Application of MALDI-TOF mass spectrometry in clinical diagnostic microbiology.

    PubMed

    De Carolis, Elena; Vella, Antonietta; Vaccaro, Luisa; Torelli, Riccardo; Spanu, Teresa; Fiori, Barbara; Posteraro, Brunella; Sanguinetti, Maurizio

    2014-09-12

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful technique for identification of microorganisms, changing the workflow of well-established laboratories so that its impact on microbiological diagnostics has been unparalleled. In comparison with conventional identification methods that rely on biochemical tests and require long incubation procedures, MALDI-TOF MS has the advantage of identifying bacteria and fungi directly from colonies grown on culture plates in a few minutes and with simple procedures. Numerous studies on different systems available demonstrate the reliability and accuracy of the method, and new frontiers have been explored besides microbial species level identification, such as direct identification of pathogens from positive blood cultures, subtyping, and drug susceptibility detection.

  5. A simple and low-cost chip bonding solution for high pressure, high temperature and biological applications.

    PubMed

    Serra, M; Pereiro, I; Yamada, A; Viovy, J-L; Descroix, S; Ferraro, D

    2017-02-14

    The sealing of microfluidic devices remains a complex and time-consuming process requiring specific equipment and protocols: a universal method is thus highly desirable. We propose here the use of a commercially available sealing tape as a robust, versatile, reversible solution, compatible with cell and molecular biology protocols, and requiring only the application of manually achievable pressures. The performance of the seal was tested with regards to the most commonly used chip materials. For most materials, the bonding resisted 5 bars at room temperature and 1 bar at 95 °C. This method should find numerous uses, ranging from fast prototyping in the laboratory to implementation in low technology environments or industrial production.

  6. Molecular Diagnostics of Fusion and Laboratory Plasmas

    NASA Astrophysics Data System (ADS)

    Fantz, U.

    2005-05-01

    The presence of molecules in the cold scrape-off layer of fusion experiments and industrial plasmas requires an understanding of the molecular dynamics in these low temperature plasmas. Suitable diagnostic methods can provide an insight in molecular processes in the plasma volume as well as for plasma surface interactions. A very simple but powerful technique is the molecular emission spectroscopy. Spectra are obtained easily, whereas interpretation might be very complex and relies on the availability of atomic and molecular data. Examples are given for hydrogen plasmas and plasmas with hydrocarbons which both are of importance in industrial applications as well as in fusion experiments.

  7. Evaluating the efficiency of spectral resolution of univariate methods manipulating ratio spectra and comparing to multivariate methods: An application to ternary mixture in common cold preparation

    NASA Astrophysics Data System (ADS)

    Moustafa, Azza Aziz; Salem, Hesham; Hegazy, Maha; Ali, Omnia

    2015-02-01

    Simple, accurate, and selective methods have been developed and validated for simultaneous determination of a ternary mixture of Chlorpheniramine maleate (CPM), Pseudoephedrine HCl (PSE) and Ibuprofen (IBF), in tablet dosage form. Four univariate methods manipulating ratio spectra were applied, method A is the double divisor-ratio difference spectrophotometric method (DD-RD). Method B is double divisor-derivative ratio spectrophotometric method (DD-RD). Method C is derivative ratio spectrum-zero crossing method (DRZC), while method D is mean centering of ratio spectra (MCR). Two multivariate methods were also developed and validated, methods E and F are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods have the advantage of simultaneous determination of the mentioned drugs without prior separation steps. They were successfully applied to laboratory-prepared mixtures and to commercial pharmaceutical preparation without any interference from additives. The proposed methods were validated according to the ICH guidelines. The obtained results were statistically compared with the official methods where no significant difference was observed regarding both accuracy and precision.

  8. A simple approximation for the current-voltage characteristics of high-power, relativistic diodes

    DOE PAGES

    Ekdahl, Carl

    2016-06-10

    A simple approximation for the current-voltage characteristics of a relativistic electron diode is presented. The approximation is accurate from non-relativistic through relativistic electron energies. Although it is empirically developed, it has many of the fundamental properties of the exact diode solutions. Lastly, the approximation is simple enough to be remembered and worked on almost any pocket calculator, so it has proven to be quite useful on the laboratory floor.

  9. Integration of scanned document management with the anatomic pathology laboratory information system: analysis of benefits.

    PubMed

    Schmidt, Rodney A; Simmons, Kim; Grimm, Erin E; Middlebrooks, Michael; Changchien, Rosy

    2006-11-01

    Electronic document management systems (EDMSs) have the potential to improve the efficiency of anatomic pathology laboratories. We implemented a novel but simple EDMS for scanned documents as part of our laboratory information system (AP-LIS) and collected cost-benefit data with the intention of discerning the value of such a system in general and whether integration with the AP-LIS is advantageous. We found that the direct financial benefits are modest but the indirect and intangible benefits are large. Benefits of time savings and access to data particularly accrued to pathologists and residents (3.8 h/d saved for 26 pathologists and residents). Integrating the scanned document management system (SDMS) into the AP-LIS has major advantages in terms of workflow and overall simplicity. This simple, integrated SDMS is an excellent value in a practice like ours, and many of the benefits likely apply in other practice settings.

  10. Determination of molybenum in soils and rocks: A geochemical semimicro field method

    USGS Publications Warehouse

    Ward, F.N.

    1951-01-01

    Reconnaissance work in geochemical prospecting requires a simple, rapid, and moderately accurate method for the determination of small amounts of molybdenum in soils and rocks. The useful range of the suggested procedure is from 1 to 32 p.p.m. of molybdenum, but the upper limit can be extended. Duplicate determinations on eight soil samples containing less than 10 p.p.m. of molybdenum agree within 1 p.p.m., and a comparison of field results with those obtained by a conventional laboratory procedure shows that the method is sufficiently accurate for use in geochemical prospecting. The time required for analysis and the quantities of reagents needed have been decreased to provide essentially a "test tube" method for the determination of molybdenum in soils and rocks. With a minimum amount of skill, one analyst can make 30 molybdenum determinations in an 8-hour day.

  11. Rapid identification of drug-type strains in Cannabis sativa using loop-mediated isothermal amplification assay.

    PubMed

    Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei

    2017-01-01

    In Cannabis sativa L., tetrahydrocannabinol (THC) is the primary psychoactive compound and exists as the carboxylated form, tetrahydrocannabinolic acid (THCA). C. sativa is divided into two strains based on THCA content-THCA-rich (drug-type) strains and THCA-poor (fiber-type) strains. Both strains are prohibited by law in many countries including Japan, whereas the drug-type strains are regulated in Canada and some European countries. As the two strains cannot be discriminated by morphological analysis, a simple method for identifying the drug-type strains is required for quality control in legal cultivation and forensic investigation. We have developed a novel loop-mediated isothermal amplification (LAMP) assay for identifying the drug-type strains of C. sativa. We designed two selective LAMP primer sets for on-site or laboratory use, which target the drug-type THCA synthase gene. The LAMP assay was accomplished within approximately 40 min. The assay showed high specificity for the drug-type strains and its sensitivity was the same as or higher than that of conventional polymerase chain reaction. We also showed the effectiveness of melting curve analysis that was conducted after the LAMP assay. The melting temperature values of the drug-type strains corresponded to those of the cloned drug-type THCA synthase gene, and were clearly different from those of the cloned fiber-type THCA synthase gene. Moreover, the LAMP assay with simple sample preparation could be accomplished within 1 h from sample treatment to identification without the need for special devices or techniques. Our rapid, sensitive, specific, and simple assay is expected to be applicable to laboratory and on-site detection.

  12. Predictive modelling of flow in a two-dimensional intermediate-scale, heterogeneous porous media

    USGS Publications Warehouse

    Barth, Gilbert R.; Hill, M.C.; Illangasekare, T.H.; Rajaram, H.

    2000-01-01

    To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.

  13. A simple, less invasive stripper micropipetter-based technique for day 3 embryo biopsy.

    PubMed

    Cedillo, Luciano; Ocampo-Bárcenas, Azucena; Maldonado, Israel; Valdez-Morales, Francisco J; Camargo, Felipe; López-Bayghen, Esther

    2016-01-01

    Preimplantation genetic screening (PGS) is an important procedure for in vitro fertilization (IVF). A key step of PGS, blastomere removal, is abundant with many technical issues. The aim of this study was to compare a more simple procedure based on the Stipper Micropipetter, named S-biopsy, to the conventional aspiration method. On Day 3, 368 high-quality embryos (>7 cells on Day3 with <10% fragmentation) were collected from 38 women. For each patient, their embryos were equally separated between the conventional method ( n  = 188) and S-biopsy method ( n  = 180). The conventional method was performed using a standardized protocol. For the S-biopsy method, a laser was used to remove a significantly smaller portion of the zona pellucida. Afterwards, the complete embryo was aspirated with a Stripper Micropipetter, forcing the removal of the blastomere. Selected blastomeres went to PGS using CGH microarrays. Embryo integrity and blastocyst formation were assessed on Day 5. Differences between groups were assessed by either the Mann-Whitney test or Fisher Exact test. Both methods resulted in the removal of only one blastomere. The S-biopsy and the conventional method did not differ in terms of affecting embryo integrity (95.0% vs. 95.7%) or blastocyst formation (72.7% vs. 70.7%). PGS analysis indicated that aneuploidy rate were similar between the two methods (63.1% vs. 65.2%). However, the time required to perform the S-biopsy method (179.2 ± 17.5 s) was significantly shorter (5-fold) than the conventional method. The S-biopsy method is comparable to the conventional method that is used to remove a blastomere for PGS, but requires less time. Furthermore, due to the simplicity of the S-biopsy technique, this method is more ideal for IVF laboratories.

  14. A simple LC-MS method for determination of cyasterone in rat plasma: application to a pilot pharmacokinetic study.

    PubMed

    Li, Fuqiang; Li, Guangyu; Zhao, Jinsong; Xiao, Jun; Liu, Zaoxia; Su, Guanfang

    2016-06-01

    A simple, specific, and sensitive liquid chromatography-mass spectrometry (LC-MS) method for determination of cyasterone in rat plasma was developed in our laboratory. Cucurbitacin B was used as an internal standard (IS). After protein precipitation with twofold volume of acetonitrile, the analyte and IS were separated on a Luna C18 column (100 × 4.6 mm, i.d., 3.0 µm; Phenomenex) by isocratic elution with acetonitrile-water (80:20, v/v) as the mobile phase at a flow rate of 0.4 mL/min. An electrospray ionization source was applied and operated in the positive ion mode; selected ion monitoring scan mode was used for quantification, and the target ions m/z 543.3 for cyasterone and m/z 581.3 for IS were chosen. Good linearity was observed in the concentration range of 0.40-400 ng/mL for cyasterone in rat plasma. Intra-day and inter-day precision were both <7.4%. This method was proved to be suitable for pharmacokinetic studies after oral (5.0 mg/kg) or intravenous (0.5 mg/kg) administration of cyasterone in rats. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Nanoribbon field-effect transistors as direct and label-free sensors of enzyme-substrate interactions

    NASA Astrophysics Data System (ADS)

    Mu, Luye; Droujinine, Ilia; Rajan, Nitin; Sawtelle, Sonya; Reed, Mark

    2015-03-01

    The ability to measure enzyme-substrate interactions is essential in areas such as diagnostics, treatment, and biochemical screens. Many enzymatic reactions alter the pH of its environment, suggesting of a simple and direct method for detection. We show the ability of Al2O3-coated Si nanoribbon field-effect transistor biosensors to sensitively measure various aspects of enzyme-substrate interactions through measuring the pH. Urea in phosphate buffered saline (PBS) and penicillinase in PBS and urine were measured to limits of <200 μM and 0.02 units/mL, respectively. We also show the ability to extract accurate kinetics from the interaction of acetylcholine and its esterase. Prior work on FET sensors has been limited by the use of surface functionalization, which not only alters enzyme-substrate affinity, but also makes enzyme activity quantification difficult. Our method involves direct detection of reactions in solution without requiring alteration to the reactants, allowing us to obtain repeatable results and sensitive limits of detection. This method is a simple, inexpensive, and effective platform for detection of enzymatic reactions, and can be readily generalized to many unrelated classes of reactants. This work was supported in part by U.S. Army Research Office and Air Force Research Laboratory.

  16. Rapid prototyping of Fresnel zone plates via direct Ga(+) ion beam lithography for high-resolution X-ray imaging.

    PubMed

    Keskinbora, Kahraman; Grévent, Corinne; Eigenthaler, Ulrike; Weigand, Markus; Schütz, Gisela

    2013-11-26

    A significant challenge to the wide utilization of X-ray microscopy lies in the difficulty in fabricating adequate high-resolution optics. To date, electron beam lithography has been the dominant technique for the fabrication of diffractive focusing optics called Fresnel zone plates (FZP), even though this preparation method is usually very complicated and is composed of many fabrication steps. In this work, we demonstrate an alternative method that allows the direct, simple, and fast fabrication of FZPs using focused Ga(+) beam lithography practically, in a single step. This method enabled us to prepare a high-resolution FZP in less than 13 min. The performance of the FZP was evaluated in a scanning transmission soft X-ray microscope where nanostructures as small as sub-29 nm in width were clearly resolved, with an ultimate cutoff resolution of 24.25 nm, demonstrating the highest first-order resolution for any FZP fabricated by the ion beam lithography technique. This rapid and simple fabrication scheme illustrates the capabilities and the potential of direct ion beam lithography (IBL) and is expected to increase the accessibility of high-resolution optics to a wider community of researchers working on soft X-ray and extreme ultraviolet microscopy using synchrotron radiation and advanced laboratory sources.

  17. Determination of hydroxyurea in human plasma by HPLC-UV using derivatization with xanthydrol.

    PubMed

    Legrand, Tiphaine; Rakotoson, Marie-Georgine; Galactéros, Frédéric; Bartolucci, Pablo; Hulin, Anne

    2017-10-01

    A simple and rapid high performance liquid chromatography (HPLC) method using ultraviolet (UV) detection was developed to determine hydroxyurea (HU) concentration in plasma sample after derivatization with xanthydrol. Two hundred microliters samples were spiked with methylurea (MeU) as internal standard and proteins were precipitated by adding methanol. Derivatization of HU and MeU was immediately performed by adding 0.02M xanthydrol and 1.5M HCl in order to obtain xanthyl-derivatives of HU and MeU that can be further separated using HPLC and quantified using UV detection at 240nm. Separation was achieved using a C18 column with a mobile phase composed of 20mM ammonium acetate and acetonitrile in gradient elution mode at a flow rate of 1mL/min. The total analysis time did not exceed 18min. The method was found linear from 5 to 400μM and all validation parameters fulfilled the international requirements. Between- and within-run accuracy error ranged from -4.7% to 3.2% and precision was lower than 12.8%. This simple method requires small volume samples and can be easily implemented in most clinical laboratories to develop pharmacokinetics studies of HU and to promote its therapeutic monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Synthesis and Characterization of Silver Nanoparticles for an Undergraduate Laboratory

    ERIC Educational Resources Information Center

    Orbaek, Alvin W.; McHale, Mary M.; Barron, Andrew R.

    2015-01-01

    The aim of this simple, quick, and safe laboratory exercise is to provide undergraduate students an introduction to nanotechnology using nanoparticle (NP) synthesis. Students are provided two procedures that allow for the synthesis of different yet controlled sizes of silver NPs. After preparing the NPs, the students perform UV-visible…

  19. Experimenting with Impacts in a Conceptual Physics or Descriptive Astronomy Laboratory

    ERIC Educational Resources Information Center

    LoPresto, Michael C.

    2016-01-01

    What follows is a description of the procedure for and results of a simple experiment on the formation of impact craters designed for the laboratory portions of lower mathematical-level general education science courses such as conceptual physics or descriptive astronomy. The experiment provides necessary experience with data collection and…

  20. A Simple, Low-Cost, Data-Logging Pendulum Built from a Computer Mouse

    ERIC Educational Resources Information Center

    Gintautas, Vadas; Hubler, Alfred

    2009-01-01

    Lessons and homework problems involving a pendulum are often a big part of introductory physics classes and laboratory courses from high school to undergraduate levels. Although laboratory equipment for pendulum experiments is commercially available, it is often expensive and may not be affordable for teachers on fixed budgets, particularly in…

  1. A Modified Bagnold-Type Wind Tunnel for Laboratory Use

    ERIC Educational Resources Information Center

    Logan, Alan

    1975-01-01

    Using the basic Bagnold design, a relatively inexpensive suction-type wind tunnel can be constructed for laboratory demonstration of sand-grain movement, ripple development, and other eolian processes. Its simple design provides no workshop problems and it can be made for a total cost in materials of approximately $225. (Author/CP)

  2. Laboratory Experiments on the Electrochemical Remediation of the Environment. Part 8. Microscale Simultaneous Photocatalysis

    ERIC Educational Resources Information Center

    Ibanez, Jorge G.; Mena-Brito, Rodrigo; Fregoso-Infante, Arturo

    2005-01-01

    A microscale experiment in which the simultaneous oxidation of an organic compound and the reduction of a metal ion are photocatalytically performed in an aqueous slurry containing TiO[subscript 2] irradiated with UV light. This experiment can be performed in the laboratory session with simple chemicals and equipments.

  3. Combining a Standard Fischer Esterification Experiment with Stereochemical and Molecular-Modeling Concepts

    ERIC Educational Resources Information Center

    Clausen, Thomas P.

    2011-01-01

    The Fisher esterification reaction is ideally suited for the undergraduate organic laboratory because it is easy to carry out and often involves a suitable introduction to basic laboratory techniques including extraction, distillation, and simple spectroscopic (IR and NMR) analyses. Here, a Fisher esterification reaction is described in which the…

  4. Mother Earth Chemistry: A Laboratory Course for Nonmajors.

    ERIC Educational Resources Information Center

    Roberts, J. L.; And Others

    1996-01-01

    Describes a laboratory course that introduces students to chemistry using examples commonly encountered in the supermarket and on the dinner table. Acquaints students with simple chemical tasks that can be practiced at home, including the making of wine, ale, soap, cheese, and yogurt, and introduces them to the small-scale production of…

  5. A DNA Melting Exercise for a Large Laboratory Class

    ERIC Educational Resources Information Center

    Levine, Lauren A.; Junker, Matthew; Stark, Myranda; Greenleaf, Dustin

    2015-01-01

    A simple and economical experimental setup is described that enables multiple individuals or groups within a laboratory class to measure the thermal melting of double stranded DNA simultaneously. The setup utilizes a basic spectrophotometer capable of measuring absorbance at 260 nm, UV plastic cuvettes, and a stirring hot plate. Students measure…

  6. Introducing Human Population Biology through an Easy Laboratory Exercise on Mitochondrial DNA

    ERIC Educational Resources Information Center

    Pardinas, Antonio F.; Dopico, Eduardo; Roca, Agustin; Garcia-Vazquez, Eva; Lopez, Belen

    2010-01-01

    This article describes an easy and cheap laboratory exercise for students to discover their own mitochondrial haplogroup. Students use buccal swabs to obtain mucosa cells as noninvasive tissue samples, extract DNA, and with a simple polymerase chain reaction-restriction fragment length polymorphism analysis they can obtain DNA fragments of…

  7. Synthesis of a Photoluminescent and Triboluminescent Copper(I) Compound: An Experiment for an Advanced Inorganic Chemistry Laboratory

    ERIC Educational Resources Information Center

    Marchetti, Fabio; Di Nicola, Corrado; Pettinari, Riccardo; Timokhin, Ivan; Pettinari, Claudio

    2012-01-01

    A simple synthesis is proposed from inexpensive reactants of a copper(I) derivative that exhibits strong photoluminescence and, in the crystalline form, exhibits strong triboluminescence. This laboratory provides an opportunity for introducing students to the phenomenon of triboluminescence. (Contains 1 scheme and 4 figures.)

  8. The Equilibrium Constant for Bromothymol Blue: A General Chemistry Laboratory Experiment Using Spectroscopy

    ERIC Educational Resources Information Center

    Klotz, Elsbeth; Doyle, Robert; Gross, Erin; Mattson, Bruce

    2011-01-01

    A simple, inexpensive, and environmentally friendly undergraduate laboratory experiment is described in which students use visible spectroscopy to determine a numerical value for an equilibrium constant, K[subscript c]. The experiment correlates well with the lecture topic of equilibrium even though the subject of the study is an acid-base…

  9. Easy Ways to Promote Inquiry in a Laboratory Course: The Power of Student Questions

    ERIC Educational Resources Information Center

    Polacek, Kelly Myer; Keeling, Elena Levine

    2005-01-01

    To teach students to think like scientists, the authors modified their laboratory course to include regular opportunities for student practice of inquiry and the scientific process. Their techniques are simple; they can be implemented without rewriting lab manuals, require little additional grading beyond typical lab reports, and are applicable…

  10. Forest Products Laboratory natural finish

    Treesearch

    J. M. Black; D. F. Laughnan; E. A. Mraz

    1979-01-01

    A simple and durable exterior natural finish developed at the Forest Products Laboratory is described. The finish is classified as a semi-transparent oil-base penetrating stain that effectively retains much of the natural grain and texture of wood when exposed to the weather. The directions for preparation are included as are the recommendations for application to both...

  11. HPLC of the Polypeptides in a Hydrolyzate of Egg-White Lysozyme. An Experiment for the Undergraduate Biochemistry Laboratory.

    ERIC Educational Resources Information Center

    Richardson, W. S., III; Burns, L.

    1988-01-01

    Describes a simple high-performance liquid chromatography experiment for undergraduate biochemistry laboratories. The experiment illustrates the separation of polypeptides by a step gradient elution using a single pump instrument with no gradient attachments. Discusses instrumentation, analysis, a sample preparation, and results. (CW)

  12. Implementation of Artificial Intelligence Assessment in Engineering Laboratory Education

    ERIC Educational Resources Information Center

    Samarakou, Maria; Fylladitakis, Emmanouil D.; Prentakis, Pantelis; Athineos, Spyros

    2014-01-01

    In laboratory courses, the assessment of exercises and assignments typically is treated as a simple, quantifiable approach. This approach however rarely includes qualitative factors, especially if the grading is being automatically performed by the system, and provides little to no feedback for the students to reflect on their work. The role of…

  13. "Split Cast Mounting: Review and New Technique".

    PubMed

    Gundawar, S M; Pande, Neelam A; Jaiswal, Priti; Radke, U M

    2014-12-01

    For the fabrication of a prosthesis, the Prosthodontist meticulously performs all the steps. The laboratory technician then make every effort/strives to perform the remaining lab procedures. However when the processed dentures are remounted on the articulator, some changes are seen. These changes may be divided into two categories: Pre-insertion and post-insertion changes, which deal with the physical properties of the materials involved (Parker, J Prosthet Dent 31:335-342, 1974). Split cast mounting is the method of mounting casts on the articulator. It is essentially a maxillary cast constructed in two parts with a horizontal division. The procedure allows for the verification of the accuracy of the initial mounting and the ease of removal and replacement of the cast. This provides a precise means of correcting the changes in occlusion occurring as a result of the processing technique (Nogueira et al., J Prosthet Dent 91:386-388, 2004). Instability of the split mounting has always been a problem to the Prosthodontist thereby limiting its use. There are various materials mentioned in the literature. The new technique by using Dowel pins and twill thread is very easy, cheaper and simple way to stabilize the split mounting. It is useful and easy in day to day laboratory procedures. The article presents different methods of split cast mounting and the new procedure using easily available materials in prosthetic laboratory.

  14. Speed of light demonstration using Doppler beat

    NASA Astrophysics Data System (ADS)

    Bernal, Luis; Bilbao, Luis

    2018-05-01

    From an apparatus previously designed for measuring the Doppler shift using a rotating mirror, an improved, versatile version was developed for speed of light demonstrations in a classroom or a teaching laboratory. By adding a second detector and adequate beam-splitter and mirrors, three different configurations are easily assembled. One configuration is used for time-of-flight measurements between a near and a far detector, allowing one to measure the speed of light provided that the path length between detectors is known. Another variation is the interferometric method obtained by superposing the far and near signals in such a way that a minimum of the combined signal is obtained when the time delay makes the signals arrive out of phase by π radians. Finally, the standard Doppler configuration allows the measurement of the frequency beat as a function of the rotation frequency. The main advantages of the apparatus are (a) the experimental setup is simple and completely accessible to undergraduate students, (b) the light is visible, students can see the rays, which, with the use of appropriate screens, can be blocked at any point along their paths, (c) the experiment can take place entirely within the teaching laboratory or demonstration room (using the interferometric method, the shortest distance to the far mirror was as small as 0.5 m), and (d) different configurations can be built, including some economical setups within the budget of teaching laboratories.

  15. A hybrid microfluidic-vacuum device for direct interfacing with conventional cell culture methods

    PubMed Central

    Chung, Bong Geun; Park, Jeong Won; Hu, Jia Sheng; Huang, Carlos; Monuki, Edwin S; Jeon, Noo Li

    2007-01-01

    Background Microfluidics is an enabling technology with a number of advantages over traditional tissue culture methods when precise control of cellular microenvironment is required. However, there are a number of practical and technical limitations that impede wider implementation in routine biomedical research. Specialized equipment and protocols required for fabrication and setting up microfluidic experiments present hurdles for routine use by most biology laboratories. Results We have developed and validated a novel microfluidic device that can directly interface with conventional tissue culture methods to generate and maintain controlled soluble environments in a Petri dish. It incorporates separate sets of fluidic channels and vacuum networks on a single device that allows reversible application of microfluidic gradients onto wet cell culture surfaces. Stable, precise concentration gradients of soluble factors were generated using simple microfluidic channels that were attached to a perfusion system. We successfully demonstrated real-time optical live/dead cell imaging of neural stem cells exposed to a hydrogen peroxide gradient and chemotaxis of metastatic breast cancer cells in a growth factor gradient. Conclusion This paper describes the design and application of a versatile microfluidic device that can directly interface with conventional cell culture methods. This platform provides a simple yet versatile tool for incorporating the advantages of a microfluidic approach to biological assays without changing established tissue culture protocols. PMID:17883868

  16. Application of modern radiative transfer tools to model laboratory quartz emissivity

    NASA Astrophysics Data System (ADS)

    Pitman, Karly M.; Wolff, Michael J.; Clayton, Geoffrey C.

    2005-08-01

    Planetary remote sensing of regolith surfaces requires use of theoretical models for interpretation of constituent grain physical properties. In this work, we review and critically evaluate past efforts to strengthen numerical radiative transfer (RT) models with comparison to a trusted set of nadir incidence laboratory quartz emissivity spectra. By first establishing a baseline statistical metric to rate successful model-laboratory emissivity spectral fits, we assess the efficacy of hybrid computational solutions (Mie theory + numerically exact RT algorithm) to calculate theoretical emissivity values for micron-sized α-quartz particles in the thermal infrared (2000-200 cm-1) wave number range. We show that Mie theory, a widely used but poor approximation to irregular grain shape, fails to produce the single scattering albedo and asymmetry parameter needed to arrive at the desired laboratory emissivity values. Through simple numerical experiments, we show that corrections to single scattering albedo and asymmetry parameter values generated via Mie theory become more necessary with increasing grain size. We directly compare the performance of diffraction subtraction and static structure factor corrections to the single scattering albedo, asymmetry parameter, and emissivity for dense packing of grains. Through these sensitivity studies, we provide evidence that, assuming RT methods work well given sufficiently well-quantified inputs, assumptions about the scatterer itself constitute the most crucial aspect of modeling emissivity values.

  17. Laboratory Demonstration of Axicon-Lens Coronagraph

    NASA Astrophysics Data System (ADS)

    Choi, Jaeho; Jea, Geonho

    2018-01-01

    The results of laboratory based experiments of the proposed coronagraph using axicon-lenses that is conjunction with a method of noninterferometric quantitative phase imaging for direct imaging of exoplanets is will present. The light source is passing through tiny holes drilled on the thin metal plate is used as the simulated stellar and its companions. Those diffracted light at the edge of the holes bears a similarity to the light from the bright stellar. Those images are evaginated about the optical axis after the maximum focal length of the first axicon lens. Then the evaginated images of have cut off using the motorized iris which means the suppressed the central stellar light preferentially. Various length between the holes which represent the angular distance are examined. The laboratory experimental results are shown that the axicon-lens coronagraph has feature of ability to achieve the smaller IWA than l/D and high-contrast direct imaging. The laboratory based axicon-lens coronagraph imaging support the symbolic computation results which has potential in direct imaging for finding exoplanet and various astrophysical activities. The setup of the coronagraph is simple to build and is durable to operate. Moreover it can be transported the planets images to a broadband spectrometric instrument that able to investigate the constituent of the planetary system.

  18. Reflections on some early events related to behavior analysis of child development

    PubMed Central

    Bijou, Sidney W.

    1996-01-01

    A series of events related to the early application of behavioral principles to child behavior and development is described. The events began in the 1930s at Columbia University with a solicited letter from John B. Watson suggesting a master's degree thesis problem, and continued through the 1950s and 1960s at the University of Washington. Specifically, these happenings resulted in (a) research demonstrating that Skinner's laboratory method for studying nonhuman organisms could be profitably applied to the laboratory study of young normal children; (b) a demonstration that by successive approximations, a normal child can be operantly conditioned to respond to an arbitrary situation; (c) research showing that the effects of simple schedules of reinforcement obtained with nonhuman organisms could be duplicated in young normal and retarded children; (d) the demonstration that Skinner's operant laboratory method could be adapted to study young children in field situations; (e) research showing that operant principles can be successfully applied to the treatment of a young autistic boy with a serious visual handicap; (f) laboratory studies showing that mothers can be trained to treat their own young children who have behavior problems; (g) an in-home study demonstrating that a mother can treat her own child who has behavior problems; (h) a demonstration that operant principles can be applied effectively to teaching reading, writing, and arithmetic to children with retardation; and (i) publication of a book, Child Development: A Systematic and Empirical Theory, in collaboration with Donald M. Baer, by Prentice Hall in their Century Psychological Series. PMID:22478239

  19. "In situ" extraction of essential oils by use of Dean-Stark glassware and a Vigreux column inside a microwave oven: a procedure for teaching green analytical chemistry.

    PubMed

    Chemat, Farid; Perino-Issartier, Sandrine; Petitcolas, Emmanuel; Fernandez, Xavier

    2012-08-01

    One of the principal objectives of sustainable and green processing development remains the dissemination and teaching of green chemistry in colleges, high schools, and academic laboratories. This paper describes simple glassware that illustrates the phenomenon of extraction in a conventional microwave oven as energy source and a process for green analytical chemistry. Simple glassware comprising a Dean-Stark apparatus (for extraction of aromatic plant material and recovery of essential oils and distilled water) and a Vigreux column (as an air-cooled condenser inside the microwave oven) was designed as an in-situ extraction vessel inside a microwave oven. The efficiency of this experiment was validated for extraction of essential oils from 30 g fresh orange peel, a by-product in the production of orange juice. Every laboratory throughout the world can use this equipment. The microwave power is 100 W and the irradiation time 15 min. The method is performed at atmospheric pressure without added solvent or water and furnishes essential oils similar to those obtained by conventional hydro or steam distillation. By use of GC-MS, 22 compounds in orange peel were separated and identified; the main compounds were limonene (72.1%), β-pinene (8.4%), and γ-terpinene (6.9%). This procedure is appropriate for the teaching laboratory, does not require any special microwave equipment, and enables the students to learn the skills of extraction, and chromatographic and spectroscopic analysis. They are also exposed to a dramatic visual example of rapid, sustainable, and green extraction of an essential oil, and are introduced to successful sustainable and green analytical chemistry.

  20. An overview of methods for developing bioenergetic and life history models for rare and endangered species

    USGS Publications Warehouse

    Petersen, J.H.; DeAngelis, D.L.; Paukert, C.P.

    2008-01-01

    Many fish species are at risk to some degree, and conservation efforts are planned or underway to preserve sensitive populations. For many imperiled species, models could serve as useful tools for researchers and managers as they seek to understand individual growth, quantify predator-prey dynamics, and identify critical sources of mortality. Development and application of models for rare species however, has been constrained by small population sizes, difficulty in obtaining sampling permits, limited opportunities for funding, and regulations on how endangered species can be used in laboratory studies. Bioenergetic and life history models should help with endangered species-recovery planning since these types of models have been used successfully in the last 25 years to address management problems for many commercially and recreationally important fish species. In this paper we discuss five approaches to developing models and parameters for rare species. Borrowing model functions and parameters from related species is simple, but uncorroborated results can be misleading. Directly estimating parameters with laboratory studies may be possible for rare species that have locally abundant populations. Monte Carlo filtering can be used to estimate several parameters by means of performing simple laboratory growth experiments to first determine test criteria. Pattern-oriented modeling (POM) is a new and developing field of research that uses field-observed patterns to build, test, and parameterize models. Models developed using the POM approach are closely linked to field data, produce testable hypotheses, and require a close working relationship between modelers and empiricists. Artificial evolution in individual-based models can be used to gain insight into adaptive behaviors for poorly understood species and thus can fill in knowledge gaps. ?? Copyright by the American Fisheries Society 2008.

  1. The Effect of Performance-Based Financial Incentives on Improving Health Care Provision in Burundi: A Controlled Cohort Study

    PubMed Central

    Rudasingwa, Martin; Soeters, Robert; Bossuyt, Michel

    2015-01-01

    To strengthen the health care delivery, the Burundian Government in collaboration with international NGOs piloted performance-based financing (PBF) in 2006. The health facilities were assigned - by using a simple matching method - to begin PBF scheme or to continue with the traditional input-based funding. Our objective was to analyse the effect of that PBF scheme on the quality of health services between 2006 and 2008. We conducted the analysis in 16 health facilities with PBF scheme and 13 health facilities without PBF scheme. We analysed the PBF effect by using 58 composite quality indicators of eight health services: Care management, outpatient care, maternity care, prenatal care, family planning, laboratory services, medicines management and materials management. The differences in quality improvement in the two groups of health facilities were performed applying descriptive statistics, a paired non-parametric Wilcoxon Signed Ranks test and a simple difference-in-difference approach at a significance level of 5%. We found an improvement of the quality of care in the PBF group and a significant deterioration in the non-PBF group in the same four health services: care management, outpatient care, maternity care, and prenatal care. The findings suggest a PBF effect of between 38 and 66 percentage points (p<0.001) in the quality scores of care management, outpatient care, prenatal care, and maternal care. We found no PBF effect on clinical support services: laboratory services, medicines management, and material management. The PBF scheme in Burundi contributed to the improvement of the health services that were strongly under the control of medical personnel (physicians and nurses) in a short time of two years. The clinical support services that did not significantly improved were strongly under the control of laboratory technicians, pharmacists and non-medical personnel. PMID:25948432

  2. Consecutive Course Modules Developed with Simple Materials to Facilitate the Learning of Basic Concepts in Astronomy

    ERIC Educational Resources Information Center

    Okulu, Hasan Zuhtu; Oguz-Unver, Ayse

    2015-01-01

    From the perspective of teaching, the huge natural laboratory that astronomy provides constitutes the most prominent connection between astronomy and other branches of science. The purpose of this research was to provide educators with activities of observation using simple materials that were developed to facilitate the teaching of basic concepts…

  3. Teaching Beer's Law and Absorption Spectrophotometry with a Smart Phone: A Substantially Simplified Protocol

    ERIC Educational Resources Information Center

    Kuntzleman, Thomas S.; Jacobson, Erik C.

    2016-01-01

    A very simple protocol for teaching Beer's Law and absorption spectrophotometry using a smart phone is described. Materials commonly found in high school chemistry laboratories or even around the house may be used. Data collection and analysis is quick and easy. Despite the simple nature of the experiment, excellent results can be achieved.

  4. A Simple Technique for High Resistance Measurement

    ERIC Educational Resources Information Center

    Aguilar, Horacio Munguia; Landin, Ramon Ochoa

    2012-01-01

    A simple electronic system for the measurement of high values of resistance is shown. This system allows the measurement of resistance in the range of a few megohm up to 10[superscript 9] [omega]. We have used this system for the evaluation of CdS thin film resistance, but other practical uses in the basic physics laboratory are presented.…

  5. Special Relativity in the School Laboratory: A Simple Apparatus for Cosmic-Ray Muon Detection

    ERIC Educational Resources Information Center

    Singh, P.; Hedgeland, H.

    2015-01-01

    We use apparatus based on two Geiger-Müller tubes, a simple electronic circuit and a Raspberry Pi computer to illustrate relativistic time dilation affecting cosmic-ray muons travelling through the atmosphere to the Earth's surface. The experiment we describe lends itself to both classroom demonstration to accompany the topic of special relativity…

  6. A Simple and Affordable TTL Processor for the Classroom

    ERIC Educational Resources Information Center

    Feinberg, Dave

    2007-01-01

    This paper presents a simple 4 bit computer processor design that may be built using TTL chips for less than $65. In addition to describing the processor itself in detail, we discuss our experience using the laboratory kit and its associated machine instruction set to teach computer architecture to high school students. (Contains 3 figures and 5…

  7. A Simple "in Vitro" Culture of Freshwater Prawn Embryos for Laboratory Investigations

    ERIC Educational Resources Information Center

    Porntrai, Supaporn; Damrongphol, Praneet

    2008-01-01

    Giant freshwater prawn ("Macrobrachium rosenbergii" De Man) embryos can be cultured "in vitro" to hatching in 15% (v/v) artificial seawater (ASW). This technique can be applied as a bioassay for testing toxicity or for the effects of various substances on embryo development and can be used as a simple and low-cost model for…

  8. A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers.

    PubMed

    Sanjay, Sharma T; Dou, Maowei; Sun, Jianjun; Li, XiuJun

    2016-07-26

    Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.

  9. A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers

    PubMed Central

    Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, XiuJun

    2016-01-01

    Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings. PMID:27456979

  10. A paper/polymer hybrid microfluidic microplate for rapid quantitative detection of multiple disease biomarkers

    NASA Astrophysics Data System (ADS)

    Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, Xiujun

    2016-07-01

    Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.

  11. LETTERS AND COMMENTS: Permeability measurements in undergraduate vacuum laboratories: a simple experiment using a He leak detector

    NASA Astrophysics Data System (ADS)

    dos Santos, J. M. F.; Veloso, J. F. C. A.; Monteiro, C. M. B.

    2004-01-01

    We describe a simple experiment intended for didactic laboratory vacuum classes of undergraduate courses, using a helium leak detector. The helium throughput flowing into the vacuum volume due to the permeability of materials can be taken as a real leak, which can be measured with the helium leak detector. The experiment allows students to perform actual measurements of helium permeability constants of different materials, and access the dependence of the helium permeability throughput on the material thickness, area and helium pressure differential. As an example, a set of measurements are presented for Kapton foils, exhibiting results that are in good agreement with those presented in the literature.

  12. Stability of the line preserving flows

    NASA Astrophysics Data System (ADS)

    Figura, Przemysław

    2017-11-01

    We examine the equations that are used to describe flows which preserve field lines. We study what happens if we introduce perturbations to the governing equations. The stability of the line preserving flows in the case of the magneto-fluids permeated by magnetic fields is strictly connected to the non-null magnetic reconnection processes. In most of our study we use the Euler potential representation of the external magnetic field. We provide general expressions for the perturbations of the Euler potentials that describe the magnetic field. Similarly, we provide expressions for the case of steady flow as well as we obtain certain conditions required for the stability of the flow. In addition, for steady flows we formulate conditions under which the perturbations of the external field are negligible and the field may be described by its initial unperturbed form. Then we consider the flow equation that transforms quantities from the laboratory coordinate system to the related external field coordinate system. We introduce perturbations to the equation and obtain its simplified versions for the case of a steady flow. For a given system, use of this method allows us to simplify the considerations provided that some part of the system may be described as a perturbation. Next, to study regions favourable for the magnetic reconnection to occur we introduce a deviation vector to the basic line preserving flows condition equation. We provide expressions of the vector for some simplifying cases. This method allows us to examine if given perturbations either stabilise the system or induce magnetic reconnection. To illustrate some of our results we study two examples, namely a simple laboratory plasma flow and a simple planetary magnetosphere model.

  13. A binder-free wet chemical synthesis approach to decorate nanoflowers of bismuth oxide on Ni-foam for fabricating laboratory scale potential pencil-type asymmetric supercapacitor device.

    PubMed

    Shinde, N M; Xia, Qi Xun; Yun, Je Moon; Singh, Saurabh; Mane, Rajaram S; Kim, Kwang-Ho

    2017-05-23

    The present study involves the synthesis of a bismuth oxide (Bi 2 O 3 ) electrode consisting of an arranged nano-platelets for evolving a flower-type surface appearance on nickel-foam (Bi 2 O 3 -Ni-F) by a simple, inexpensive, binder-free and one-step chemical bath deposition (CBD) method, popularly known as a wet chemical method. The as-prepared Bi 2 O 3 on Ni-foam, as an electrode material, demonstrates 557 F g -1 specific capacitance (SC, at 1 mA cm -2 ), of which 85% is retained even after 2000 cycles. With specific power density of 500 kW kg -1 , the Bi 2 O 3 -Ni-F electrode documents a specific energy density of 80 Wh kg -1 . Furthermore, a portable asymmetric supercapacitor device, i.e. a pencil-type cell consisting of Bi 2 O 3 -Ni-F as an anode and graphite as a cathode in 6 M KOH aqueous electrolyte solution, confirms 11 Wh kg -1 and 720 kW kg -1 specific energy and specific power densities, respectively. An easy and a simple synthesis approach for manufacturing a portable laboratory scale pencil-type supercapacitor device is a major outcome of this study, which can also be applied for ternary and quaternary metal oxides for recording an enhanced performance. In addition, we presented a demonstration of lighting a light emitting diode (LED) using a home-made pencil-type supercapacitor device which, finally, has confirmed the scaling and technical potentiality of Bi 2 O 3 -Ni-F in energy storage devices.

  14. Teaching radio astronomy with Affordable Small Radio Telescope (ASRT)

    NASA Astrophysics Data System (ADS)

    Joshi, Bhal Chandra

    A simple, easy to build and portable radio telescope, called Affordable Small Radio Telescope (ASRT), has been developed by the Radio Physics Laboratory (RPL), a radio astronomy teaching unit associated with the National Centre for Radio Astrophysics (TIFR) and Inter-University Centre for Astronomy and Astrophysics (IUCAA), which are two premier astronomy institutes in India. ASRT consists of off-the-shelf available Direct to Home television dishes and is easy to assemble. Our design is scalable from simple very low cost telescope to more complex yet moderately costing instrument. ASRT provides a platform for demonstrating radio physics concepts through simple hands-on experiment as well as for carrying out solar monitoring by college/University students. The presentation will highlight the concept of ASRT and the different experiments that can be carried out using it. The solar monitoring observations will be discussed along-with details of methods for calibrating these measurements. The pedagogical usefulness of ASRT in introducing undergraduatephysics students to astrophysics, measurements and analysis methods used in radio astronomy will also be discussed. Use of ASRT in the last three years in the programs of RPL, namely the annual Radio Astronomy Winter School for College students (RAWSC) and Pulsar Observing for Students (POS) is also presented. This year a new program was initiated to form a virtual group of an ASRT community, which will not only share their measurements, but also think of improving the pedagogical usefulness of ASRT by innovative experiments. This initiative is presented with the best practices drawn from our experience in using ASRT as a tool for student training in space sciences. The talk will also point out future ideas in involving a larger body of students in simple radio astronomy experiments with the ASRT, which RPL is likely to nucleate as part of its mandate.

  15. Adenylylation of small RNA sequencing adapters using the TS2126 RNA ligase I.

    PubMed

    Lama, Lodoe; Ryan, Kevin

    2016-01-01

    Many high-throughput small RNA next-generation sequencing protocols use 5' preadenylylated DNA oligonucleotide adapters during cDNA library preparation. Preadenylylation of the DNA adapter's 5' end frees from ATP-dependence the ligation of the adapter to RNA collections, thereby avoiding ATP-dependent side reactions. However, preadenylylation of the DNA adapters can be costly and difficult. The currently available method for chemical adenylylation of DNA adapters is inefficient and uses techniques not typically practiced in laboratories profiling cellular RNA expression. An alternative enzymatic method using a commercial RNA ligase was recently introduced, but this enzyme works best as a stoichiometric adenylylating reagent rather than a catalyst and can therefore prove costly when several variant adapters are needed or during scale-up or high-throughput adenylylation procedures. Here, we describe a simple, scalable, and highly efficient method for the 5' adenylylation of DNA oligonucleotides using the thermostable RNA ligase 1 from bacteriophage TS2126. Adapters with 3' blocking groups are adenylylated at >95% yield at catalytic enzyme-to-adapter ratios and need not be gel purified before ligation to RNA acceptors. Experimental conditions are also reported that enable DNA adapters with free 3' ends to be 5' adenylylated at >90% efficiency. © 2015 Lama and Ryan; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  16. An investigation of the direct-drive method of susceptibility testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonn, R.H.

    1992-07-01

    The Naval Surface Weapons Laboratory has constructed a small electrical subsystem for the purpose of evaluating electrical upset from various electromagnetic sources. The subsystem consists of three boxes, two of which are intended to be illuminated by electromagnetic waves. The two illuminated boxes are connected by two unshielded cable bundles. The goal of the Navy test series is to expose the subsystem to electromagnetic illumination from several different types of excitation, document upset levels, and compare the results. Before its arrival at Sandia National Laboratories (SNL) the system was illuminated in a mode stirred chamber and in an anechoic chamber.more » This effort was a continuation of that test program. The Sandia tests involved the test methodology referred to as bulk current injection (BCI). Because this is a poorly-shielded, multiple-aperture system, the method was not expected to compare closely to the other test methods. The test results show that. The BCI test methodology is a useful test technique for a subset of limited aperture systems; the methodology will produce incorrect answers when used improperly on complex systems; the methodology can produce accurate answers on simple systems with a well-controlled electromagnetic topology. This is a preliminary study and the results should be interpreted carefully.« less

  17. High surface area calcite

    NASA Astrophysics Data System (ADS)

    Schultz, L. N.; Andersson, M. P.; Dalby, K. N.; Müter, D.; Okhrimenko, D. V.; Fordsmand, H.; Stipp, S. L. S.

    2013-05-01

    Calcite (CaCO3) is important in many fields—in nature, because it is a component of aquifers, oil reservoirs and prospective CO2 storage sites, and in industry, where it is used in products as diverse as paper, toothpaste, paint, plastic and aspirin. It is difficult to obtain high purity calcite with a high surface area but such material is necessary for industrial applications and for fundamental calcite research. Commercial powder is nearly always contaminated with growth inhibitors such as sugars, citrate or pectin and most laboratory synthesis methods deliver large precipitates, often containing vaterite or aragonite. To address this problem, we (i) adapted the method of carbonating a Ca(OH)2 slurry with CO2 gas to develop the first simple, cheap, safe and reproducible procedure using common laboratory equipment, to obtain calcite that reproducibly had a surface area of 14-17 m2/g and (ii) conducted a thorough characterization of the product. Scanning electron microscopy (SEM) revealed nanometer scale, rhombohedral crystals. X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and infrared spectroscopy (IR) confirmed highly crystalline, pure calcite that more closely resembles the dimensions of the biogenic calcite produced by algae in coccoliths than other methods for synthesizing calcite. We suggest that this calcite is useful when purity and high surface area are important.

  18. Birdcage volume coils and magnetic resonance imaging: a simple experiment for students.

    PubMed

    Vincent, Dwight E; Wang, Tianhao; Magyar, Thalia A K; Jacob, Peni I; Buist, Richard; Martin, Melanie

    2017-01-01

    This article explains some simple experiments that can be used in undergraduate or graduate physics or biomedical engineering laboratory classes to learn how birdcage volume radiofrequency (RF) coils and magnetic resonance imaging (MRI) work. For a clear picture, and to do any quantitative MRI analysis, acquiring images with a high signal-to-noise ratio (SNR) is required. With a given MRI system at a given field strength, the only means to change the SNR using hardware is to change the RF coil used to collect the image. RF coils can be designed in many different ways including birdcage volume RF coil designs. The choice of RF coil to give the best SNR for any MRI study is based on the sample being imaged. The data collected in the simple experiments show that the SNR varies as inverse diameter for the birdcage volume RF coils used in these experiments. The experiments were easily performed by a high school student, an undergraduate student, and a graduate student, in less than 3 h, the time typically allotted for a university laboratory course. The article describes experiments that students in undergraduate or graduate laboratories can perform to observe how birdcage volume RF coils influence MRI measurements. It is designed for students interested in pursuing careers in the imaging field.

  19. An evaluation of rise time characterization and prediction methods

    NASA Technical Reports Server (NTRS)

    Robinson, Leick D.

    1994-01-01

    One common method of extrapolating sonic boom waveforms from aircraft to ground is to calculate the nonlinear distortion, and then add a rise time to each shock by a simple empirical rule. One common rule is the '3 over P' rule which calculates the rise time in milliseconds as three divided by the shock amplitude in psf. This rule was compared with the results of ZEPHYRUS, a comprehensive algorithm which calculates sonic boom propagation and extrapolation with the combined effects of nonlinearity, attenuation, dispersion, geometric spreading, and refraction in a stratified atmosphere. It is shown there that the simple empirical rule considerably overestimates the rise time estimate. In addition, the empirical rule does not account for variations in the rise time due to humidity variation or propagation history. It is also demonstrated that the rise time is only an approximate indicator of perceived loudness. Three waveforms with identical characteristics (shock placement, amplitude, and rise time), but with different shock shapes, are shown to give different calculated loudness. This paper is based in part on work performed at the Applied Research Laboratories, the University of Texas at Austin, and supported by NASA Langley.

  20. A Simple Decontamination Approach Using Hydrogen ...

    EPA Pesticide Factsheets

    Journal article To evaluate the use of relatively low levels of hydrogen peroxide vapor (HPV) for the inactivation of Bacillus anthracis spores within an indoor environment. Methods and Results: Laboratory-scale decontamination tests were conducted using bacterial spores of both B. anthracis Ames and Bacillus atrophaeus inoculated onto several types of materials. Pilot-scale tests were also conducted using a larger chamber furnished as an indoor office. Commercial off-the-shelf (COTS) humidifiers filled with aqueous solutions of 3% or 8% hydrogen peroxide were used to generate the HPV inside the mock office. The spores were exposed to the HPV for periods ranging from 8 hours up to one week. Conclusions: Four to seven day exposures to low levels of HPV (average air concentrations of approximately 5-10 parts per million) were effective in inactivating B. anthracis spores on multiple materials. The HPV can be generated with COTS humidifiers and household H2O2 solutions. With the exception of one test/material, B. atrophaeus spores were equally or more resistant to HPV inactivation compared to those from B. anthracis Ames. Significance and Impact of Study: This simple and effective decontamination method is another option that could be widely applied in the event of a B. anthracis spore release.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, Vinita J.; Schaefer, Charles; Kahnhauser, Henry

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. Thismore » entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project’s resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed in this paper. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Finally, post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.« less

  2. On-Orbit Ephemeris Determination with Radio Doppler Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dallmann, Nicholas; Proicou, Michael Chris; Seitz, Daniel Nathan

    2016-02-09

    Multiple CubeSats are often released from the same host spacecraft into virtually the same orbit at nearly the same time. A satellite team needs the ability to identify and track its own satellites as soon as possible. However, this can be a difficult and confusing task with a large number of satellites. Los Alamos National Laboratory encountered this issue during a launch of LANL-designed CubeSats that were released with more than 20 other objects. A simple radio Doppler method used shortly after launch by the Los Alamos team to select its satellites of interest from the list of available trackedmore » ephemerides is described. This method can also be used for automated real time ephemeris validation. For future efforts, each LANL-designed CubeSat will automatically perform orbit determination from the position, velocity, and covariance estimates provided by an added on-board GPS receiver. This self-determined ephemeris will be automatically downlinked by ground stations for mission planning, antenna tracking, Doppler-pre-correction, etc. A simple algorithm based on established theory and well suited for embedded on-board processing is presented. The trades examined in selecting the algorithm components and data formats are briefly discussed, as is the expected performance.« less

  3. A probabilistic model for deriving soil quality criteria based on secondary poisoning of top predators. I. Model description and uncertainty analysis.

    PubMed

    Traas, T P; Luttik, R; Jongbloed, R H

    1996-08-01

    In previous studies, the risk of toxicant accumulation in food chains was used to calculate quality criteria for surface water and soil. A simple algorithm was used to calculate maximum permissable concentrations [MPC = no-observed-effect concentration/bioconcentration factor(NOEC/BCF)]. These studies were limited to simple food chains. This study presents a method to calculate MPCs for more complex food webs of predators. The previous method is expanded. First, toxicity data (NOECs) for several compounds were corrected for differences between laboratory animals and animals in the wild. Second, for each compound, it was assumed these NOECs were a sample of a log-logistic distribution of mammalian and avian NOECs. Third, bioaccumulation factors (BAFs) for major food items of predators were collected and were assumed to derive from different log-logistic distributions of BAFs. Fourth, MPCs for each compound were calculated using Monte Carlo sampling from NOEC and BAF distributions. An uncertainty analysis for cadmium was performed to identify the most uncertain parameters of the model. Model analysis indicated that most of the prediction uncertainty of the model can be ascribed to uncertainty of species sensitivity as expressed by NOECs. A very small proportion of model uncertainty is contributed by BAFs from food webs. Correction factors for the conversion of NOECs from laboratory conditions to the field have some influence on the final value of MPC5, but the total prediction uncertainty of the MPC is quite large. It is concluded that the uncertainty in species sensitivity is quite large. To avoid unethical toxicity testing with mammalian or avian predators, it cannot be avoided to use this uncertainty in the method proposed to calculate MPC distributions. The fifth percentile of the MPC is suggested as a safe value for top predators.

  4. Detection of Wolbachia endobacteria in Culex quinquefasciatus by Gimenez staining and confirmation by PCR.

    PubMed

    Muniaraj, M; Paramasivan, R; Sunish, I P; Arunachalam, N; Mariappan, T; Jerald Leo, S Victor; Dhananjeyan, K J

    2012-12-01

    Wolbachia are common intracellular bacteria that are found in arthropods and nematodes. These endosymbionts are transmitted vertically through host eggs and alter host biology in diverse ways, including the induction of reproductive manipulations, such as feminization, parthenogenesis, male killing and sperm-egg incompatibility. Since they can also move horizontally across species boundaries, Wolbachia is gaining importance in recent days as it could be used as a biological control agent to control vector mosquitoes or for paratransgenic approaches. However, the study of Wolbachia requires sophisticated techniques such as PCR and cell culture facilities which cannot be affordable for many laboratories where the diseases transmitted by arthropod vectors are common. Hence, it would be beneficial to develop a simple method to detect the presence of Wolbachia in arthropods. In this study, we described a method of staining Wolbachia endobacteria, present in the reproductive tissues of mosquitoes. The reliability of this method was compared with Gram staining and PCR based detection. The microscopic observation of the Gimenez stained smear prepared from the teased ovary of wild caught and Wolbachia (+) Cx. quinquefasciatus revealed the presence of pink coloured pleomorphic cells of Wolbachia ranging from cocci, comma shaped cells to bacillus and chain forms. The ovaries of Wolbachia (-) cured mosquito did not show any cell. Although Gram's staining is a reliable differential staining for the other bacteria, the bacterial cells in the smears from the ovaries of wild caught mosquitoes did not take the stain properly and the cells were not clearly visible. The PCR amplified product from the pooled remains of wild caught and Wolbachia (+) Cx. quinquefasciatus showed clear banding, whereas, no banding was observed for the negative control (distilled water) and Wolbachia (-) Cx. quinquefasciatus. The Gimenez staining technique applied, could be used to detect the members of the endobacteria Wolbachia easily, even in a simple laboratory without any special facilities or even in the field condition and for handling large number of samples in a shorter duration.

  5. Quantum Dots in a Polymer Composite: A Convenient Particle-in-a-Box Laboratory Experiment

    ERIC Educational Resources Information Center

    Rice, Charles V.; Giffin, Guinevere A.

    2008-01-01

    Semiconductor quantum dots are at the forefront of materials science chemistry with applications in biological imaging and photovoltaic technologies. We have developed a simple laboratory experiment to measure the quantum-dot size from fluorescence spectra. A major roadblock of quantum-dot based exercises is the particle synthesis and handling;…

  6. Laboratory Exercise for Studying the Morphology of Heat-Denatured and Amyloid Aggregates of Lysozyme by Atomic Force Microscopy

    ERIC Educational Resources Information Center

    Gokalp, Sumeyra; Horton, William; Jónsdóttir-Lewis, Elfa B.; Foster, Michelle; Török, Marianna

    2018-01-01

    To facilitate learning advanced instrumental techniques, essential tools for visualizing biomaterials, a simple and versatile laboratory exercise demonstrating the use of Atomic Force Microscopy (AFM) in biomedical applications was developed. In this experiment, the morphology of heat-denatured and amyloid-type aggregates formed from a low-cost…

  7. X-Ray Diffraction of Intermetallic Compounds: A Physical Chemistry Laboratory Experiment

    ERIC Educational Resources Information Center

    Varberg, Thomas D.; Skakuj, Kacper

    2015-01-01

    Here we describe an experiment for the undergraduate physical chemistry laboratory in which students synthesize the intermetallic compounds AlNi and AlNi3 and study them by X-ray diffractometry. The compounds are synthesized in a simple one-step reaction occurring in the solid state. Powder X-ray diffractograms are recorded for the two compounds…

  8. Solubility and Solubility Product Determination of a Sparingly Soluble Salt: A First-Level Laboratory Experiment

    ERIC Educational Resources Information Center

    Bonomo, Raffaele P.; Tabbi, Giovanni; Vagliasindi, Laura I.

    2012-01-01

    A simple experiment was devised to let students determine the solubility and solubility product, "K"[subscript sp], of calcium sulfate dihydrate in a first-level laboratory. The students experimentally work on an intriguing equilibrium law: the constancy of the product of the ion concentrations of a sparingly soluble salt. The determination of…

  9. Experimenting with Synthesis and Analysis of Cationic Gemini Surfactants in a Second-Semester General Chemistry Laboratory

    ERIC Educational Resources Information Center

    Anzovino, Mary E.; Greenberg, Andrew E.; Moore, John W.

    2015-01-01

    A laboratory experiment is described in which students synthesize a variety of cationic gemini surfactants and analyze their efficacy as fabric softeners. Students perform a simple organic synthesis reaction and two analytical tests (one qualitative and one quantitative), and use the class data to assess the synthesized products. The experiment…

  10. Dipeptide Structural Analysis Using Two-Dimensional NMR for the Undergraduate Advanced Laboratory

    ERIC Educational Resources Information Center

    Gonzalez, Elizabeth; Dolino, Drew; Schwartzenburg, Danielle; Steiger, Michelle A.

    2015-01-01

    A laboratory experiment was developed to introduce students in either an organic chemistry or biochemistry lab course to two-dimensional nuclear magnetic resonance (2D NMR) spectroscopy using simple biomolecules. The goal of this experiment is for students to understand and interpret the information provided by a 2D NMR spectrum. Students are…

  11. Rolling Friction on a Wheeled Laboratory Cart

    ERIC Educational Resources Information Center

    Mungan, Carl E.

    2012-01-01

    A simple model is developed that predicts the coefficient of rolling friction for an undriven laboratory cart on a track that is approximately independent of the mass loaded onto the cart and of the angle of inclination of the track. The model includes both deformation of the wheels/track and frictional torque at the axles/bearings. The concept of…

  12. An Experimental Investigation of the Role of Radiation in Laboratory Bench-Top Experiments in Thermal Physics

    ERIC Educational Resources Information Center

    Twomey, Patrick; O'Sullivan, Colm; O'Riordan, John

    2009-01-01

    A simple undergraduate experiment designed to study cooling purely by radiation and cooling by a combination of convection and radiation is described. Results indicate that the contribution from radiative cooling in normal laboratory experiments is more significant than students often realize, even in the case of forced cooling. (Contains 1…

  13. Using Visible Spectrophotometers and pH Measurements to Study Speciation in a Guided-Inquiry Laboratory

    ERIC Educational Resources Information Center

    Otto, William H.; Larive, Cynthia K.; Mason, Susan L.; Robinson, Janet B.; Heppert Joseph A.; Ellis, James D.

    2005-01-01

    An experiment to perform a simple initial investigation that illustrates concepts of speciation and equilibrium, using the instrument and chemical resources in the laboratory is presented. The investigation showed that the presence of multiple chemical species in a reaction mixture (phenol red solution) reflects the acid and base conditions…

  14. Biofeedback and Performance: An Update

    DTIC Science & Technology

    1984-12-01

    low tension level), Sabourin and Rioux (1979) measured performance on standard laboratory tasks: memorization of nonsense syllables, simple reaction... Sabourin and Rioux point out, however, most subjects undergoing laboratory experimentation are not usually (in the absence of specific treatment to...and extraneous muscle activity interferes with efficient acquisition of a psychomotor skill. Keeping in mind the effect noted by Sabourin and Rioux

  15. A Laboratory Experiment, Based on the Maillard Reaction, Conducted as a Project in Introductory Statistics

    ERIC Educational Resources Information Center

    Kravchuk, Olena; Elliott, Antony; Bhandari, Bhesh

    2005-01-01

    A simple laboratory experiment, based on the Maillard reaction, served as a project in Introductory Statistics for undergraduates in Food Science and Technology. By using the principles of randomization and replication and reflecting on the sources of variation in the experimental data, students reinforced the statistical concepts and techniques…

  16. A Simple Student Laboratory on Osmotic Flow, Osmotic Pressure, and the Reflection Coefficient.

    ERIC Educational Resources Information Center

    Feher, Joseph J.; Ford, George D.

    1995-01-01

    Describes a laboratory exercise containing a practical series of experiments that novice students can perform within two hours. The exercise provides a confirmation of van't Hoff's law while placing more emphasis on osmotic flow than pressure. Students can determine parameters such as the reflection coefficient which stress the interaction of both…

  17. A Simple Laboratory Practical to Illustrate RNA Mediated Gene Interference Using Drosophila Cell Culture

    ERIC Educational Resources Information Center

    Buluwela, Laki; Kamalati, Tahereh; Photiou, Andy; Heathcote, Dean A.; Jones, Michael D.; Ali, Simak

    2010-01-01

    RNA mediated gene interference (RNAi) is now a key tool in eukaryotic cell and molecular biology research. This article describes a five session laboratory practical, spread over a seven day period, to introduce and illustrate the technique. During the exercise, students working in small groups purify PCR products that encode "in vitro"…

  18. Projectile Activity for the Laboratory: A Safe and Inexpensive Approach to Several Concepts

    ERIC Educational Resources Information Center

    Farkas, N.; Ramsier, R. D.

    2006-01-01

    We present a simple laboratory activity for introductory-level physics students which involves rolling balls down pipes and analysing their subsequent flight trajectories. Using balls of equal size but different mass allows students to confront their misconceptions of a mass dependence of the exit speed of the balls from the pipes. The concepts of…

  19. Size Exclusion Chromatography: An Experiment for High School and Community College Chemistry and Biotechnology Laboratory Programs

    ERIC Educational Resources Information Center

    Brunauer, Linda S.; Davis, Kathryn K.

    2008-01-01

    A simple multiday laboratory exercise suitable for use in a high school or community college chemistry course or a biotechnology advanced placement biology course is described. In this experiment students gain experience in the use of column chromatography as a tool for the separation and characterization of biomolecules, thus expanding their…

  20. Improved Measures of Integrated Information

    PubMed Central

    Tegmark, Max

    2016-01-01

    Although there is growing interest in measuring integrated information in computational and cognitive systems, current methods for doing so in practice are computationally unfeasible. Existing and novel integration measures are investigated and classified by various desirable properties. A simple taxonomy of Φ-measures is presented where they are each characterized by their choice of factorization method (5 options), choice of probability distributions to compare (3 × 4 options) and choice of measure for comparing probability distributions (7 options). When requiring the Φ-measures to satisfy a minimum of attractive properties, these hundreds of options reduce to a mere handful, some of which turn out to be identical. Useful exact and approximate formulas are derived that can be applied to real-world data from laboratory experiments without posing unreasonable computational demands. PMID:27870846

  1. Quantification of Dihydroxyacetone Phosphate (DHAP) in Human Red Blood Cells by HPLC-TripleTOF 5600™ Mass Spectrometer.

    PubMed

    Deng, Shuang; Scott, David; Myers, Douglas; Garg, Uttam

    2016-01-01

    Triosephosphate isomerase (TPI) is a glycolytic enzyme which catalyzes the interconversion between glyceraldehyde-3-phosphate (G3P) and dihydroxyacetone phosphate (DHAP). TPI deficiency results in accumulation of DHAP in human red blood cells and other tissues. The disease is characterized by congenital hemolytic anemia, and progressive neuromuscular dysfunction. The laboratory diagnosis is generally made by measurement of TPI activity in RBCs. Measurement of DHAP can be useful in further confirmation and follow-up of the disease. We developed HPLC/TOF-MS method for quantitation of DHAP in RBCs. The method involves simple protein precipitation, reverse phase C8 column chromatography, ion pairing with tributylamine, and long run time of 50 min to separate the two isomers (G3P and DHAP).

  2. Cyanoacrylate Skin Surface Stripping and the 3S-Biokit Advent in Tropical Dermatology: A Look from Liège

    PubMed Central

    Piérard, Gérald E.; Piérard-Franchimont, Claudine; Paquet, Philippe; Hermanns-Lê, Trinh; Delvenne, Philippe

    2014-01-01

    In the dermatopathology field, some simple available laboratory tests require minimum equipment for establishing a diagnosis. Among them, the cyanoacrylate skin surface stripping (CSSS), formerly named skin surface biopsy or follicular biopsy, represents a convenient low cost procedure. It is a minimally invasive method collecting a continuous sheet of stratum corneum and horny follicular casts. In the vast majority of cases, it is painless and is unassociated with adverse events. CSSS can be performed in subjects of any age. The method has a number of applications in diagnostic dermatopathology and cosmetology, as well as in experimental dermatology settings. A series of derived analytic procedures include xerosis grading, comedometry, corneofungimetry, corneodynamics of stratum corneum renewal, corneomelametry, corneosurfametry, and corneoxenometry. PMID:25177726

  3. A simple method of measuring the wear of explanted acetabular component inserts

    PubMed Central

    Krakow, L.; Klockow, A.; Roehner, E.; Brodt, S.; Eijer, H.; Bossert, J.

    2017-01-01

    Objectives The determination of the volumetric polyethylene wear on explanted material requires complicated equipment, which is not available in many research institutions. Our aim in this study was to present and validate a method that only requires a set of polyetheretherketone balls and a laboratory balance to determine wear. Methods The insert to be measured was placed on a balance, and a ball of the appropriate diameter was inserted. The cavity remaining between the ball and insert caused by wear was filled with contrast medium and the weight of the contrast medium was recorded. The volume was calculated from the known density of the liquid. The precision, inter- and intraobserver reliability, were determined by four investigators on four days using nine inserts with specified wear (0.094 ml to 1.626 ml), and the intra-class correlation coefficient was calculated. The feasibility of using this method in routine clinical practice and the time required for measurement were tested on 84 explanted inserts by one investigator. Results In order to get the mean for all investigators and determinations, the deviation between the measured and specified wear was -0.08 ml (sd 0.12; -0.21 to 0.11). The interobserver reliability was 0.989 ml (95% confidence interval (CI) 0.964 to 0.997) and the intraobserver reliability was 0.941 for observer 1 (95% CI 0.846 to 0.985), 0.983 for observer 2 (95% CI 0.956 to 0.995), 0.939 for observer 3 (95% CI 0.855 to 0.984), and 0.934 for observer 4 (95% CI 0.790 to 0.984). The mean time required to examine the samples was two minutes (sd 2; 1 to 5). Conclusion The method presented here was shown to be sufficiently precise for many settings and is a cost-effective and quick method of determining the volumetric wear of explanted acetabular components. However, the measurement of wear for scientific purposes will probably continue to involve more accurate and dedicated laboratory equipment. Cite this article: L. Krakow, A. Klockow, E. Roehner, S. Brodt, H. Eijer, J. Bossert, G. Matziolis. A simple method of measuring the wear of explanted acetabular component inserts. Bone Joint Res 2017;6:530–534. DOI: 10.1302/2046-3758.69.BJR-2016-0249.R1 PMID:28899855

  4. Time Trials--An AP Physics Challenge Lab

    ERIC Educational Resources Information Center

    Jones, David

    2009-01-01

    I have come to the conclusion that for high school physics classroom and laboratory experiences, simpler is better! In this paper I describe a very simple and effective lab experience that my AP students have thoroughly enjoyed year after year. I call this lab exercise "Time Trials." The experiment is simple in design and it is a lot of fun for…

  5. Simple and Inexpensive 3D Printed Filter Fluorometer Designs: User-Friendly Instrument Models for Laboratory Learning and Outreach Activities

    ERIC Educational Resources Information Center

    Porter, Lon A., Jr.; Chapman, Cole A.; Alaniz, Jacob A.

    2017-01-01

    In this work, a versatile and user-friendly selection of stereolithography (STL) files and computer-aided design (CAD) models are shared to assist educators and students in the production of simple and inexpensive 3D printed filter fluorometer instruments. These devices are effective resources for supporting active learners in the exploration of…

  6. Application of a simple power law for transport ratio with bimodal distributions of spherical grains under oscillatory forcing

    NASA Astrophysics Data System (ADS)

    Holway, Kevin; Thaxton, Christopher S.; Calantoni, Joseph

    2012-11-01

    Morphodynamic models of coastal evolution require relatively simple parameterizations of sediment transport for application over larger scales. Calantoni and Thaxton (2008) [6] presented a transport parameterization for bimodal distributions of coarse quartz grains derived from detailed boundary layer simulations for sheet flow and near sheet flow conditions. The simulation results, valid over a range of wave forcing conditions and large- to small-grain diameter ratios, were successfully parameterized with a simple power law that allows for the prediction of the transport rates of each size fraction. Here, we have applied the simple power law to a two-dimensional cellular automaton to simulate sheet flow transport. Model results are validated with experiments performed in the small oscillating flow tunnel (S-OFT) at the Naval Research Laboratory at Stennis Space Center, MS, in which sheet flow transport was generated with a bed composed of a bimodal distribution of non-cohesive grains. The work presented suggests that, under the conditions specified, algorithms that incorporate the power law may correctly reproduce laboratory bed surface measurements of bimodal sheet flow transport while inherently incorporating vertical mixing by size.

  7. Development of a molecular method for testing the effectiveness of UV systems on-site.

    PubMed

    Nizri, Limor; Vaizel-Ohayon, Dalit; Ben-Amram, Hila; Sharaby, Yehonatan; Halpern, Malka; Mamane, Hadas

    2017-12-15

    We established a molecular method for quantifying ultraviolet (UV) disinfection efficacy using total bacterial DNA in a water sample. To evaluate UV damage to the DNA, we developed the "DNA damage" factor, which is a novel cultivation-independent approach that reveals UV-exposure efficiency by applying a simple PCR amplification method. The study's goal was to prove the feasibility of this method for demonstrating the efficiency of UV systems in the field using flow-through UV reactors. In laboratory-based experiments using seeded bacteria, the DNA damage tests demonstrated a good correlation between PCR products and UV dose. In the field, natural groundwater sampled before and after being subjected to the full-scale UV reactors was filtered, and the DNA extracted from the filtrate was subjected to PCR amplification for a 900-bp fragment of the 16S rRNA gene with initial DNA concentrations of 0.1 and 1 ng/μL. In both cases, the UV dose predicted and explained a significant proportion of the variance in the log inactivation ratio and DNA damage factor. Log inactivation ratio was very low, as expected in groundwater due to low initial bacterial counts, whereas the DNA damage factor was within the range of values obtained in the laboratory-based experiments. Consequently, the DNA damage factor reflected the true performance of the full-scale UV system during operational water flow by using the indigenous bacterial array present in a water sample. By applying this method, we were able to predict with high confidence, the UV reactor inactivation potential. For method validation, laboratory and field iterations are required to create a practical field calibration curve that can be used to determine the expected efficiency of the full-scale UV system in the field under actual operation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Adaptations of the Saker-Solomons test: simple, reliable colorimetric field assays for chloroquine and its metabolites in urine.

    PubMed

    Mount, D L; Nahlen, B L; Patchen, L C; Churchill, F C

    1989-01-01

    Two field-adapted colorimetric methods for measuring the antimalarial drug chloroquine in urine are described. Both are modifications of the method of Saker and Solomons for screening urine for phencyclidine and other drugs of abuse, using the colour reagent tetrabromophenolphthalein ethyl ester. One method is semiquantitative, detecting the presence of chloroquine (Cq) and its metabolites in urine with a 1 microgram/ml detection limit; it is more sensitive and reliable than the commonly used Dill-Glazko method and is as easy to apply in the field. The second method uses a hand-held, battery-operated filter photometer to quantify Cq and its metabolites with a 2 microgram/ml detection limit and a linear range up to 8 micrograms/ml. The first method was validated in the field using a published quantitative colorimetric method and samples from a malaria study in Nigeria. The second method was validated in the laboratory against high-performance liquid chromatographic results on paired samples from the Nigerian study. Both methods may be used in remote locations where malaria is endemic and no electricity is available.

  9. A new relative referencing method for crop monitoring using chlorophyll fluorescence

    NASA Technical Reports Server (NTRS)

    Norikane, J.; Goto, E.; Kurata, K.; Takakura, T.

    2003-01-01

    The measurement of plant chlorophyll fluorescence has been used for many years as a method to monitor a plant's health status. These types of methods have been mostly relegated to the laboratory. The newly developed Relative Referencing Method allows for the measurement of chlorophyll fluorescence under artificial lighting conditions. The fluorescence signal can be determined by first taking a reference signal measurement, then a second measurement with an additional fluorescence excitation source. The first signal can then be subtracted from the second and the plant's chlorophyll fluorescence due to the second lighting source can be determined. With this simple approach, a photosynthesizing plant can be monitored to detect signs of water stress. Using this approach experiments on tomato plants have shown that it was possible to detect water stress, while the plants were continuously illuminated by fluorescent lamps. This method is a promising tool for the remote monitoring of crops grown in a CELSS-type application. Published by Elsevier Science Ltd on behalf of COSPAR.

  10. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method.

    PubMed

    Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz

    2017-01-01

    High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.

  11. Hand-eye calibration for rigid laparoscopes using an invariant point.

    PubMed

    Thompson, Stephen; Stoyanov, Danail; Schneider, Crispin; Gurusamy, Kurinchi; Ourselin, Sébastien; Davidson, Brian; Hawkes, David; Clarkson, Matthew J

    2016-06-01

    Laparoscopic liver resection has significant advantages over open surgery due to less patient trauma and faster recovery times, yet it can be difficult due to the restricted field of view and lack of haptic feedback. Image guidance provides a potential solution but one current challenge is in accurate "hand-eye" calibration, which determines the position and orientation of the laparoscope camera relative to the tracking markers. In this paper, we propose a simple and clinically feasible calibration method based on a single invariant point. The method requires no additional hardware, can be constructed by theatre staff during surgical setup, requires minimal image processing and can be visualised in real time. Real-time visualisation allows the surgical team to assess the calibration accuracy before use in surgery. In addition, in the laboratory, we have developed a laparoscope with an electromagnetic tracking sensor attached to the camera end and an optical tracking marker attached to the distal end. This enables a comparison of tracking performance. We have evaluated our method in the laboratory and compared it to two widely used methods, "Tsai's method" and "direct" calibration. The new method is of comparable accuracy to existing methods, and we show RMS projected error due to calibration of 1.95 mm for optical tracking and 0.85 mm for EM tracking, versus 4.13 and 1.00 mm respectively, using existing methods. The new method has also been shown to be workable under sterile conditions in the operating room. We have proposed a new method of hand-eye calibration, based on a single invariant point. Initial experience has shown that the method provides visual feedback, satisfactory accuracy and can be performed during surgery. We also show that an EM sensor placed near the camera would provide significantly improved image overlay accuracy.

  12. Remote Control and Data Acquisition: A Case Study

    NASA Technical Reports Server (NTRS)

    DeGennaro, Alfred J.; Wilkinson, R. Allen

    2000-01-01

    This paper details software tools developed to remotely command experimental apparatus, and to acquire and visualize the associated data in soft real time. The work was undertaken because commercial products failed to meet the needs. This work has identified six key factors intrinsic to development of quality research laboratory software. Capabilities include access to all new instrument functions without any programming or dependence on others to write drivers or virtual instruments, simple full screen text-based experiment configuration and control user interface, months of continuous experiment run-times, order of 1% CPU load for condensed matter physics experiment described here, very little imposition of software tool choices on remote users, and total remote control from anywhere in the world over the Internet or from home on a 56 Kb modem as if the user is sitting in the laboratory. This work yielded a set of simple robust tools that are highly reliable, resource conserving, extensible, and versatile, with a uniform simple interface.

  13. Validation of the ANSR® Listeria Method for Detection of Listeria spp. in Selected Foods.

    PubMed

    Caballero, Oscar; Alles, Susan; Wendorf, Michael; Gray, R Lucas; Walton, Kayla; Pinkava, Lisa; Mozola, Mark; Rice, Jennifer

    2015-01-01

    ANSR® Listeria was previously certified as Performance Tested Method(SM) 101202 for detection of Listeria spp. on selected environmental surfaces. This study proposes a matrix extension to the method for detection of Listeria spp. in selected food matrixes. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in less than 50 min, requiring only simple instrumentation. Inclusivity testing was performed using a panel of 51 strains of Listeria spp., representing the species L. grayi, L. innocua, L. ivanovii, L. monocytogenes, L. seeligeri, and L. welshimeri. All strains tested were detected by the ANSR assay. Exclusivity testing of 30 strains representing non-Listeria Gram-positive bacteria yielded no evidence of cross-reactivity. Performance of the ANSR method for detection of Listeria spp. was compared to that of reference culture procedures for pasteurized liquid egg, pasteurized 2% milk, Mexican-style cheese, ice cream, smoked salmon, lettuce, cantaloupe, and guacamole. Data obtained in these unpaired studies and analyzed using a probability of detection model demonstrated that there were no statistically significant differences in results between the ANSR and reference culture methods, except for milk at 16 h and cantaloupe. In milk and smoked salmon, ANSR sensitivity was low at 16 h and therefore the recommended incubation time is 24 h. In cantaloupe, ANSR was found to be more sensitive than the reference culture method at both 16 and 24 h in independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in selected food types.

  14. Detection of heavy metal by paper-based microfluidics.

    PubMed

    Lin, Yang; Gritsenko, Dmitry; Feng, Shaolong; Teh, Yi Chen; Lu, Xiaonan; Xu, Jie

    2016-09-15

    Heavy metal pollution has shown great threat to the environment and public health worldwide. Current methods for the detection of heavy metals require expensive instrumentation and laborious operation, which can only be accomplished in centralized laboratories. Various microfluidic paper-based analytical devices have been developed recently as simple, cheap and disposable alternatives to conventional ones for on-site detection of heavy metals. In this review, we first summarize current development of paper-based analytical devices and discuss the selection of paper substrates, methods of device fabrication, and relevant theories in these devices. We then compare and categorize recent reports on detection of heavy metals using paper-based microfluidic devices on the basis of various detection mechanisms, such as colorimetric, fluorescent, and electrochemical methods. To finalize, the future development and trend in this field are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Development of a simplified and convenient assay for cell-mediated immunity to the mumps virus.

    PubMed

    Otani, Naruhito; Shima, Masayuki; Nakajima, Kazuhiko; Takesue, Yoshio; Okuno, Toshiomi

    2014-09-01

    Because methods for measuring cell-mediated immunity (CMI) to the mumps virus are expensive, time-consuming, and technically demanding, the role of CMI in mumps virus infection remains unclear. To address this issue, we report here the development of a simplified method for measuring mumps virus-specific CMI that is suitable for use in diverse laboratory and clinical settings. A mumps vaccine was cultured with whole blood, and interferon (IFN)-γ released into the culture supernatant was measured using an enzyme-linked immunosorbent assay. IFN-γ production in blood from vaccinated subjects markedly increased in response to the vaccine and decreased before the antibody titer decreased in some cases, suggesting that this assay may be used as a simple surrogate method for measuring CMI specific for the mumps virus. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Standardised evaluation of the performance of a simple membrane filtration-elution method to concentrate bacteriophages from drinking water.

    PubMed

    Méndez, Javier; Audicana, Ana; Isern, Ana; Llaneza, Julián; Moreno, Belén; Tarancón, María Luisa; Jofre, Juan; Lucena, Francisco

    2004-04-01

    The bacteriophage elution procedure described further after adsorption to acetate-nitrate cellulose membrane filters allows better recovery of phages concentrated from 1l of water than elution procedures used previously. The improvement is due to the combined effect of the eluent (3% (w/v) beef extract, 3% (v/v) Tween 80, 0.5M NaCl, pH 9.0) and the application of ultrasound instead of agitation or swirling. Average recovery of somatic coliphages, 82 +/- 7%, was the greatest, and that of phages infecting Bacteroides fragilis, 56 +/- 8%, the lowest, with intermediate values for F-specific and F-specific RNA bacteriophages. Thus, the method allowed recovery of over 56% for all the phages suggested as surrogate indicators. The method was then validated according to an International Standardisation Organisation validation standard procedure and implemented in routine laboratories, which obtained reproducible results.

  17. On-chip purification via liquid immersion of arc-discharge synthesized multiwalled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Hokkanen, Matti J.; Lautala, Saara; Shao, Dongkai; Turpeinen, Tuomas; Koivistoinen, Juha; Ahlskog, Markus

    2016-07-01

    Arc-discharge synthesized multiwalled carbon nanotubes (AD-MWNT) have been proven to be of high quality, but their use is very limited due to difficulties in obtaining them in a clean and undamaged form. Here, we present a simple method that purifies raw AD-MWNT material in laboratory scale without damage, and that in principle can be scaled up. The method consists of depositing raw AD-MWNT material on a flat substrate and immersing the substrate slowly in water, whereby the surface tension force of the liquid-substrate contact line selectively sweeps away the larger amorphous carbon debris and leaves relatively clean MWNTs on the substrate. We demonstrate the utility of the method by preparing clean individual MWNTs for measurement of their Raman spectra. The spectra exhibit the characteristics of high-quality tubes free from contaminants. We also show how one concomitantly with the purification process can obtain large numbers of clean suspended MWNTs.

  18. Isolation of rat adrenocortical mitochondria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solinas, Paola; Department of Medicine, Center for Mitochondrial Disease, School of Medicine, Case Western Reserve University, Cleveland, OH 44106; Fujioka, Hisashi

    2012-10-12

    Highlights: Black-Right-Pointing-Pointer A method for isolation of adrenocortical mitochondria from the adrenal gland of rats is described. Black-Right-Pointing-Pointer The purified isolated mitochondria show excellent morphological integrity. Black-Right-Pointing-Pointer The properties of oxidative phosphorylation are excellent. Black-Right-Pointing-Pointer The method increases the opportunity of direct analysis of adrenal mitochondria from small animals. -- Abstract: This report describes a relatively simple and reliable method for isolating adrenocortical mitochondria from rats in good, reasonably pure yield. These organelles, which heretofore have been unobtainable in isolated form from small laboratory animals, are now readily accessible. A high degree of mitochondrial purity is shown by the electronmore » micrographs, as well as the structural integrity of each mitochondrion. That these organelles have retained their functional integrity is shown by their high respiratory control ratios. In general, the biochemical performance of these adrenal cortical mitochondria closely mirrors that of typical hepatic or cardiac mitochondria.« less

  19. Thermal and enzymatic recovering of proteins from untanned leather waste.

    PubMed

    Bajza, Z; Vrucek, V

    2001-01-01

    The laboratory trials of a process to treat untanned leather waste to isolate valuable protein products are presented. In this comparative study, both thermal and enzymatic treatments of leather waste were performed. The enzymatic method utilizes commercially available alkaline protease at moderate temperatures and for short periods of time. The concentration of the enzyme was 500 units per gram of leather waste which makes the method cost-effective. Amino acid composition in the hydrolysate obtained by the enzyme hydrolysis of untanned leather waste is determined. Chemical and physical properties of protein powder products from untanned leather waste were evaluated by spectrophotometric and chromatographic methods and by use of electron microscope. The results of microbiological assays confirm that these products agree to food safety standards. This relatively simple treatment of untanned leather waste may provide a practical and economical solution to the disposal of potentially dangerous waste.

  20. Simultaneous determination of the HIV nucleoside analogue reverse transcriptase inhibitors lamivudine, didanosine, stavudine, zidovudine and abacavir in human plasma by reversed phase high performance liquid chromatography.

    PubMed

    Verweij-van Wissen, C P W G M; Aarnoutse, R E; Burger, D M

    2005-02-25

    A reversed phase high performance liquid chromatography method was developed for the simultaneous quantitative determination of the nucleoside reverse transcriptase inhibitors (NRTIs) lamivudine, didanosine, stavudine, zidovudine and abacavir in plasma. The method involved solid-phase extraction with Oasis MAX cartridges from plasma, followed by high performance liquid chromatography with a SymmetryShield RP 18 column and ultraviolet detection set at a wavelength of 260 nm. The assay was validated over the concentration range of 0.015-5 mg/l for all five NRTIs. The average accuracies for the assay were 92-102%, inter- and intra-day coefficients of variation (CV) were <2.5% and extraction recoveries were higher than 97%. This method proved to be simple, accurate and precise, and is currently in use in our laboratory for the quantitative analysis of NRTIs in plasma.

Top