Electronic test and calibration circuits, a compilation
NASA Technical Reports Server (NTRS)
1972-01-01
A wide variety of simple test calibration circuits are compiled for the engineer and laboratory technician. The majority of circuits were found inexpensive to assemble. Testing electronic devices and components, instrument and system test, calibration and reference circuits, and simple test procedures are presented.
Ranking protective coatings: Laboratory vs. field experience
NASA Astrophysics Data System (ADS)
Conner, Jeffrey A.; Connor, William B.
1994-12-01
Environmentally protective coatings are used on a wide range of gas turbine components for survival in the harsh operating conditions of engines. A host of coatings are commercially available to protect hot-section components, ranging from simple aluminides to designer metallic overlays and ceramic thermal barrier coatings. A variety of coating-application processes are available, and they range from simple pack cementation processing to complex physical vapor deposition, which requires multimillion dollar facilities. Detailed databases are available for most coatings and coating/process combinations for a range of laboratory tests. Still, the analysis of components actually used in engines often yields surprises when compared against predicted coating behavior from laboratory testing. This paper highlights recent work to develop new laboratory tests that better simulate engine environments. Comparison of in-flight coating performance as well as industrial and factory engine testing on a range of hardware is presented along with laboratory predictions from standard testing and from recently developed cyclic burner-rig testing.
Wong, Carlos K H; Siu, Shing-Chung; Wan, Eric Y F; Jiao, Fang-Fang; Yu, Esther Y T; Fung, Colman S C; Wong, Ka-Wai; Leung, Angela Y M; Lam, Cindy L K
2016-05-01
The aim of the present study was to develop a simple nomogram that can be used to predict the risk of diabetes mellitus (DM) in the asymptomatic non-diabetic subjects based on non-laboratory- and laboratory-based risk algorithms. Anthropometric data, plasma fasting glucose, full lipid profile, exercise habits, and family history of DM were collected from Chinese non-diabetic subjects aged 18-70 years. Logistic regression analysis was performed on a random sample of 2518 subjects to construct non-laboratory- and laboratory-based risk assessment algorithms for detection of undiagnosed DM; both algorithms were validated on data of the remaining sample (n = 839). The Hosmer-Lemeshow test and area under the receiver operating characteristic (ROC) curve (AUC) were used to assess the calibration and discrimination of the DM risk algorithms. Of 3357 subjects recruited, 271 (8.1%) had undiagnosed DM defined by fasting glucose ≥7.0 mmol/L or 2-h post-load plasma glucose ≥11.1 mmol/L after an oral glucose tolerance test. The non-laboratory-based risk algorithm, with scores ranging from 0 to 33, included age, body mass index, family history of DM, regular exercise, and uncontrolled blood pressure; the laboratory-based risk algorithm, with scores ranging from 0 to 37, added triglyceride level to the risk factors. Both algorithms demonstrated acceptable calibration (Hosmer-Lemeshow test: P = 0.229 and P = 0.483) and discrimination (AUC 0.709 and 0.711) for detection of undiagnosed DM. A simple-to-use nomogram for detecting undiagnosed DM has been developed using validated non-laboratory-based and laboratory-based risk algorithms. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
2004-01-01
Laboratories performing waived testing must follow the manufacturer's instructions as well as good laboratory practices to ensure that test results are reliable. Four things to concentrate on to maximize the performance and reliability of waived tests are to: 1. Read and follow the information found in the package inserts. 2. Follow the manufacturer's recommendations for running quality control. 3. Train staff members to perform tests correctly. 4. Follow established policies and procedures for patient testing in the practice.
Su, Bin-Guang; Chen, Shao-Fen; Yeh, Shu-Hsing; Shih, Po-Wen; Lin, Ching-Chiang
2016-11-01
To cope with the government's policies to reduce medical costs, Taiwan's healthcare service providers are striving to survive by pursuing profit maximization through cost control. This article aimed to present the results of cost evaluation using activity-based costing performed in the laboratory in order to throw light on the differences between costs and the payment system of National Health Insurance (NHI). This study analyzed the data of costs and income of the clinical laboratory. Direct costs belong to their respective sections of the department. The department's shared costs, including public expenses and administrative assigned costs, were allocated to the department's respective sections. A simple regression equation was created to predict profit and loss, and evaluate the department's break-even point, fixed cost, and contribution margin ratio. In clinical chemistry and seroimmunology sections, the cost per test was lower than the NHI payment and their major laboratory tests had revenues with the profitability ratio of 8.7%, while the other sections had a higher cost per test than the NHI payment and their major tests were in deficit. The study found a simple linear regression model as follows: "Balance=-84,995+0.543×income (R2=0.544)". In order to avoid deficit, laboratories are suggested to increase test volumes, enhance laboratory test specialization, and become marginal scale. A hospital could integrate with regional medical institutions through alliances or OEM methods to increase volumes to reach marginal scale and reduce laboratory costs, enhancing the level and quality of laboratory medicine.
Cole, Laurence A; Khanlian, Sarah A
2004-05-01
False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.
Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites
Lucchi, Naomi W.; Gaye, Marie; Diallo, Mammadou Alpha; Goldman, Ira F.; Ljolje, Dragan; Deme, Awa Bineta; Badiane, Aida; Ndiaye, Yaye Die; Barnwell, John W.; Udhayakumar, Venkatachalam; Ndiaye, Daouda
2016-01-01
Isothermal nucleic acid amplification assays such as the loop mediated isothermal amplification (LAMP), are well suited for field use as they do not require thermal cyclers to amplify the DNA. To further facilitate the use of LAMP assays in remote settings, simpler sample preparation methods and lyophilized reagents are required. The performance of a commercial malaria LAMP assay (Illumigene Malaria LAMP) was evaluated using two sample preparation workflows (simple filtration prep (SFP)) and gravity-driven filtration prep (GFP)) and pre-dispensed lyophilized reagents. Laboratory and clinical samples were tested in a field laboratory in Senegal and the results independently confirmed in a reference laboratory in the U.S.A. The Illumigene Malaria LAMP assay was easily implemented in the clinical laboratory and gave similar results to a real-time PCR reference test with limits of detection of ≤2.0 parasites/μl depending on the sample preparation method used. This assay reliably detected Plasmodium sp. parasites in a simple low-tech format, providing a much needed alternative to the more complex molecular tests for malaria diagnosis. PMID:27827432
Maui Space Surveillance System Satellite Categorization Laboratory
NASA Astrophysics Data System (ADS)
Deiotte, R.; Guyote, M.; Kelecy, T.; Hall, D.; Africano, J.; Kervin, P.
The MSSS satellite categorization laboratory is a fusion of robotics and digital imaging processes that aims to decompose satellite photometric characteristics and behavior in a controlled setting. By combining a robot, light source and camera to acquire non-resolved images of a model satellite, detailed photometric analyses can be performed to extract relevant information about shape features, elemental makeup, and ultimately attitude and function. Using the laboratory setting a detailed analysis can be done on any type of material or design and the results cataloged in a database that will facilitate object identification by "curve-fitting" individual elements in the basis set to observational data that might otherwise be unidentifiable. Currently the laboratory has created, an ST-Robotics five degree of freedom robotic arm, collimated light source and non-focused Apogee camera have all been integrated into a MATLAB based software package that facilitates automatic data acquisition and analysis. Efforts to date have been aimed at construction of the lab as well as validation and verification of simple geometric objects. Simple tests on spheres, cubes and simple satellites show promising results that could lead to a much better understanding of non-resolvable space object characteristics. This paper presents a description of the laboratory configuration and validation test results with emphasis on the non-resolved photometric characteristics for a variety of object shapes, spin dynamics and orientations. The future vision, utility and benefits of the laboratory to the SSA community as a whole are also discussed.
Simple Flame Test Techniques Using Cotton Swabs
ERIC Educational Resources Information Center
Sanger, Michael J.; Phelps, Amy J.; Banks, Catherine
2004-01-01
Three alternative methods for performing flame tests using cheaply and easily available cotton swabs are described. These flame tests are useful for chemical demonstrations or laboratory experiments because they are quick and easy to perform with easy cleanup and disposal methods.
Madhivanan, Purnima; Krupp, Karl; Hardin, Jill; Karat, Chitra; Klausner, Jeffrey D; Reingold, Arthur L
2009-06-01
Bacterial vaginosis (BV) and Trichomonas vaginalis infection (TV) have been associated with adverse birth outcomes and increased risk for HIV. We compare the performance of simple inexpensive point-of-care (POC) tests to laboratory diagnosis and syndromic management of BV and TV in poor settings. Between November 2005 and March 2006, 898 sexually active women attending two reproductive health clinics in Mysore, India were recruited into a cohort study investigating the relationship between vaginal flora and HSV-2 infection. Participants were interviewed and screened for reproductive tract infections. Laboratory tests included serology for HSV-2; cultures for TV, Candida sp., and Neisseria gonorrhoeae; Gram stains; and two POC tests: vaginal pH; and Whiff test. Of the 898 participants, 411 [45.7%, 95% confidence interval (95% CI): 42.4-49.0%] had any laboratory diagnosed vaginal infection. BV was detected in 165 women (19.1%, 95%CI: 16.5-21.9%) using Nugent score. TV was detected in 76 women (8.5%, 95%CI: 6.7-10.4%) using culture. Among the entire study population, POC correctly detected 82% of laboratory diagnosed BV cases, and 83% of laboratory diagnosed TV infections. Among women with complaints of vulval itching, burning, abnormal vaginal discharge, and/or sores (445/898), POC correctly detected 83% (60 of 72 cases) of laboratory diagnosed BV cases vs. 40% (29 of 72 cases) correctly managed using the syndromic approach (P < 0.001). Similarly, POC would have detected 82% (37 of 45 cases) of TV cases vs. 51% (23 of 45 cases) correctly managed using the syndromic approach (P = 0.001). In the absence of laboratory diagnostics, POC is not only inexpensive and practical, but also significantly more sensitive than the syndromic management approach, resulting in less overtreatment. .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bourdon, J.C.; Peltier, B.; Cooper, G.A.
In this paper, field drill-off test results are compared with data from laboratory simulations. A simple theory for analyzing drill-off tests is developed. The weight-on bit (WOB) decay with time is close to exponential, but large threshold WOB's, resulting from poor weight transmission downhole, are sometimes observed in field tests.
Robust 1-Bit Compressive Sensing via Binary Stable Embeddings of Sparse Vectors
2011-04-15
funded by Mitsubishi Electric Research Laboratories. †ICTEAM Institute, ELEN Department, Université catholique de Louvain (UCL), B-1348 Louvain-la-Neuve...reduced to a simple comparator that tests for values above or below zero, enabling extremely simple, efficient, and fast quantization. A 1-bit quantizer is...these two terms appears to be significantly different, according to the previously discussed experiments. To test the hypothesis that this term is the key
Developing a cardiopulmonary exercise testing laboratory.
Diamond, Edward
2007-12-01
Cardiopulmonary exercise testing is a noninvasive and cost-effective technique that adds significant value to the assessment and management of a variety of symptoms and diseases. The penetration of this testing in medical practice may be limited by perceived operational and financial barriers. This article reviews coding and supervision requirements related to both simple and complex pulmonary stress testing. A program evaluation and review technique diagram is used to describe the work flow process. Data from our laboratory are used to generate an income statement that separates fixed and variable costs and calculates the contribution margin. A cost-volume-profit (break-even) analysis is then performed. Using data from our laboratory including fixed and variable costs, payer mix, reimbursements by payer, and the assumption that the studies are divided evenly between simple and complex pulmonary stress tests, the break-even number is calculated to be 300 tests per year. A calculator with embedded formulas has been designed by the author and is available on request. Developing a cardiopulmonary exercise laboratory is challenging but achievable and potentially profitable. It should be considered by a practice that seeks to distinguish itself as a quality leader. Providing this clinically valuable service may yield indirect benefits such as increased patient volume and increased utilization of other services provided by the practice. The decision for a medical practice to commit resources to managerial accounting support requires a cost-benefit analysis, but may be a worthwhile investment in our challenging economic environment.
A Simple "in Vitro" Culture of Freshwater Prawn Embryos for Laboratory Investigations
ERIC Educational Resources Information Center
Porntrai, Supaporn; Damrongphol, Praneet
2008-01-01
Giant freshwater prawn ("Macrobrachium rosenbergii" De Man) embryos can be cultured "in vitro" to hatching in 15% (v/v) artificial seawater (ASW). This technique can be applied as a bioassay for testing toxicity or for the effects of various substances on embryo development and can be used as a simple and low-cost model for…
ERIC Educational Resources Information Center
Anzovino, Mary E.; Greenberg, Andrew E.; Moore, John W.
2015-01-01
A laboratory experiment is described in which students synthesize a variety of cationic gemini surfactants and analyze their efficacy as fabric softeners. Students perform a simple organic synthesis reaction and two analytical tests (one qualitative and one quantitative), and use the class data to assess the synthesized products. The experiment…
DOT National Transportation Integrated Search
2000-04-01
An innovative and simple approach is presented for estimation of the resilient modulus of subgrade soils utilizing the cone penetration test. Field and laboratory testing programs were carried out at seven sites that comprise three common soil types ...
A Shack Interferometer Setup for Optical Testing in Undergraduate Courses
ERIC Educational Resources Information Center
Vannoni, Maurizio; Righini, Alberto; Salas, Matias; Sordini, Andrea; Vanzi, Leonardo
2012-01-01
The Shack interferometer is a simple and effective device to test optical surfaces in reflection and optical systems in transmission. An essential setup on a reduced scale with a minimum number of components is presented, suited to gain familiarity and practice with optical testing in a laboratory course for undergraduate students. The basic…
Wallace, Jack
2010-05-01
While forensic laboratories will soon be required to estimate uncertainties of measurement for those quantitations reported to the end users of the information, the procedures for estimating this have been little discussed in the forensic literature. This article illustrates how proficiency test results provide the basis for estimating uncertainties in three instances: (i) For breath alcohol analyzers the interlaboratory precision is taken as a direct measure of uncertainty. This approach applies when the number of proficiency tests is small. (ii) For blood alcohol, the uncertainty is calculated from the differences between the laboratory's proficiency testing results and the mean quantitations determined by the participants; this approach applies when the laboratory has participated in a large number of tests. (iii) For toxicology, either of these approaches is useful for estimating comparability between laboratories, but not for estimating absolute accuracy. It is seen that data from proficiency tests enable estimates of uncertainty that are empirical, simple, thorough, and applicable to a wide range of concentrations.
Purohit, Manju Raj; Sharma, Megha; Rosales-Klintz, Senia; Lundborg, Cecilia Stålsby
2015-08-11
Delay in diagnosis is one of the most important factors for the control of tuberculosis (TB) in endemic countries like India. As laboratory diagnosis is the mainstay for identification of active disease, we aim to explore and understand the opinions of medical doctors about the laboratory diagnosis of TB in Ujjain, India. Sixteen qualified specialist medical doctors from Ujjain were purposefully selected for the study. Individual interviews with the doctors (13 men and 3 women), were conducted. As one interview could not be completed, data from 15 interviews were analyzed using manifest and latent content analysis. Based on perception of the doctors, the theme; 'challenges and need for the laboratory diagnosis of TB' emerged from the following subthemes: (i) Relationship between basic element of the TB diseases process such as 'Symptoms prior to diagnoses' and 'Clinical characteristics of TB', which were not specific enough to diagnose TB (ii) The prevailing conditions such as lack of explicit diagnostic tools, lead to the doctors using the 'multiple tests' or 'empiric treatment' approach (iii) The doctors proposed that there is a need for access to a rapid, single and simple diagnostic test, and a need for awareness and knowledge of the practitioners regarding specific TB investigations, and early referral to improve the situation at resource-limited settings. The medical specialists use a 'multiple test' or 'empiric treatment' approach to diagnose TB. According to the participants, there is a low dependence and uptake of the available laboratory TB investigations by medical practitioners. There is an urgent need to have a specific, simple and reliable test, and a protocol, to improve diagnosis of TB and to prevent development of resistant TB.
Evans, Rand B
2017-01-01
Beginning in 1 9a0, a major thread of research was added to E. B. Titchener's Cornell laboratory: the synthetic experiment. Titchener and his graduate students used introspective analysis to reduce a perception, a complex experience, into its simple sensory constituents. To test the validity of that analysis, stimulus patterns were selected to reprodiuce the patterns of sensations found in the introspective analyses. If the original perception can be reconstructed in this way, then the analysis was considered validated. This article reviews development of the synthetic method in E. B. Titchener's laboratory at Cornell University and examines its impact on psychological research.
ERIC Educational Resources Information Center
Boffa, Vittorio; Yue, Yuanzheng; He, Wen
2012-01-01
As part of a laboratory course, undergraduate students were asked to use baker's yeast cells as biotemplate in preparing TiO[subscript 2] powders and to test the photocatalytic activity of the resulting materials. This laboratory experience, selected because of the important environmental implications of soft chemistry and photocatalysis, provides…
Plant tests required for the registration of pesticides are generally performed under controlled laboratory/greenhouse conditions using single exposures, and the results may or may not be relevant to protecting plant communities or ecosystems. We report results from a field test ...
Lipid and lipoprotein testing in resource-limited laboratories.
Myers, Gary L
2003-01-01
The role of total cholesterol (TC) and lipoproteins in the assessment of coronary heart disease (CHD) is firmly established from population and intervention studies. Total and low-density lipoprotein cholesterol (LDLC) levels are positively associated with CHD, and high-density lipoprotein cholesterol (HDLC) levels are negatively associated with CHD. Efforts to identify and treat people at increased risk based on cholesterol and lipoprotein levels have led to more lipid testing and the need for very reliable test results. Thus, quality laboratory services are an essential component of healthcare delivery and play a vital role in any strategy to reduce morbidity and mortality from CHD. In laboratories with limited resources, establishing laboratory capability to measure CHD risk markers may be a considerable challenge. Laboratories face problems in selecting proper techniques, difficulties in equipment availability and maintenance, and shortage of supplies, staffing, and supervision. The Centers for Disease Control and Prevention (CDC) has been providing technical assistance for more than 30 years to laboratories that measure lipids and lipoproteins and is willing to provide technical assistance as needed for other laboratories to develop this capability. CDC can provide technical assistance to establish lipid and lipoprotein testing capability to support a CHD public health program in areas with limited laboratory resources. This assistance includes: selecting a suitable testing instrument; providing training for laboratory technicians; establishing a simple quality control plan; and instructing staff on how to prepare frozen serum control materials suitable for assessing accuracy of lipid and lipoprotein testing.
Mohammed, Emad A; Naugler, Christopher
2017-01-01
Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.
Mohammed, Emad A.; Naugler, Christopher
2017-01-01
Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand. PMID:28400996
A Standardized Soil Ecotoxicological Test Using Red Worms (Eisenia fetida).
ERIC Educational Resources Information Center
Paradise, Christopher J.
2001-01-01
Describes a simple, inexpensive test for soil contamination that can be used in a variety of courses to examine the effects of soil toxicity, to practice standardized laboratory procedures, to study experimental design and data analysis, or to investigate earthworm ecology. Presents background information along with details regarding equipment,…
A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt
Carol A. Clausen; Vina W. Yang
2011-01-01
Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...
ERIC Educational Resources Information Center
Schwartz, Marjorie F.
1989-01-01
Discusses simple analysis of urine in the classroom. Describes the materials and procedures for the analysis. Provides a laboratory report giving characteristics of: (1) odor, color, and clarity; (2) specific gravity; (3) sediment; (4) test strips; and (5) albumin and phosphates. (YP)
Inter-laboratory validation of bioaccessibility testing for metals.
Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R
2014-10-01
Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.
Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peascoe, RA
2001-09-25
Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less
Asensio, C; Gasco, L; Ruiz, M; Recuero, M
2015-02-01
This paper describes a methodology and case study for the implementation of educational virtual laboratories for practice training on acoustic tests according to international standards. The objectives of this activity are (a) to help the students understand and apply the procedures described in the standards and (b) to familiarize the students with the uncertainty in measurement and its estimation in acoustics. The virtual laboratory will not focus on the handling and set-up of real acoustic equipment but rather on procedures and uncertainty. The case study focuses on the application of the virtual laboratory for facade sound insulation tests according to ISO 140-5:1998 (International Organization for Standardization, Geneva, Switzerland, 1998), and the paper describes the causal and stochastic models and the constraints applied in the virtual environment under consideration. With a simple user interface, the laboratory will provide measurement data that the students will have to process to report the insulation results that must converge with the "virtual true values" in the laboratory. The main advantage of the virtual laboratory is derived from the customization of factors in which the student will be instructed or examined (for instance, background noise correction, the detection of sporadic corrupted observations, and the effect of instrument precision).
Potato Types and Characteristics: Laboratory Exercises.
ERIC Educational Resources Information Center
Pavlista, Alexander D.
1997-01-01
Presents a number of simple exercises that demonstrate potato tuber characteristics and are designed for high school biology students and teachers. Exercises include Typing, Grading, Shape, Eye Characteristics, Defects, Specific Gravity, Dry Matter Content, Glucose Content, Baking, Frying/Chipping, and Taste Testing. (JRH)
Digital lock-in amplifier based on soundcard interface for physics laboratory
NASA Astrophysics Data System (ADS)
Sinlapanuntakul, J.; Kijamnajsuk, P.; Jetjamnong, C.; Chotikaprakhan, S.
2017-09-01
The purpose of this paper is to develop a digital lock-in amplifier based on soundcard interface for undergraduate physics laboratory. Both series and parallel RLC circuit laboratory are tested because of its well-known, easy to understand and simple confirm. The sinusoidal signal at the frequency of 10 Hz - 15 kHz is generated to the circuits. The amplitude and phase of the voltage drop across the resistor, R are measured in 10 step decade. The signals from soundcard interface and lock-in amplifier are compared. The results give a good correlation. It indicates that the design digital lock-in amplifier is promising for undergraduate physic laboratory.
Pencil-and-Paper Neural Networks: An Undergraduate Laboratory Exercise in Computational Neuroscience
Crisp, Kevin M.; Sutter, Ellen N.; Westerberg, Jacob A.
2015-01-01
Although it has been more than 70 years since McCulloch and Pitts published their seminal work on artificial neural networks, such models remain primarily in the domain of computer science departments in undergraduate education. This is unfortunate, as simple network models offer undergraduate students a much-needed bridge between cellular neurobiology and processes governing thought and behavior. Here, we present a very simple laboratory exercise in which students constructed, trained and tested artificial neural networks by hand on paper. They explored a variety of concepts, including pattern recognition, pattern completion, noise elimination and stimulus ambiguity. Learning gains were evident in changes in the use of language when writing about information processing in the brain. PMID:26557791
Implementing Computer Based Laboratories
NASA Astrophysics Data System (ADS)
Peterson, David
2001-11-01
Physics students at Francis Marion University will complete several required laboratory exercises utilizing computer-based Vernier probes. The simple pendulum, the acceleration due to gravity, simple harmonic motion, radioactive half lives, and radiation inverse square law experiments will be incorporated into calculus-based and algebra-based physics courses. Assessment of student learning and faculty satisfaction will be carried out by surveys and test results. Cost effectiveness and time effectiveness assessments will be presented. Majors in Computational Physics, Health Physics, Engineering, Chemistry, Mathematics and Biology take these courses, and assessments will be categorized by major. To enhance the computer skills of students enrolled in the courses, MAPLE will be used for further analysis of the data acquired during the experiments. Assessment of these enhancement exercises will also be presented.
Fast determination of soil behavior in the capillary zone using simple laboratory tests.
DOT National Transportation Integrated Search
2012-12-01
Frost heave and thaw weakening are typical problems for engineers building in northern regions. These unsaturated-soil behaviors are : caused by water flowing through the capillary zone to a freezing front, where it forms ice lenses. Although suction...
Laboratory errors and patient safety.
Miligy, Dawlat A
2015-01-01
Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that evaluated the encountered laboratory errors and launch the great need for universal standardization and bench marking measures to control the laboratory work.
Plebani, Mario
2018-05-24
In the last few decades, laboratory medicine has undergone monumental changes, and laboratory technology, which has made enormous advances, now has new clinical applications thanks to the identification of a growing number of biomarkers and risk factors conducive to the promotion of predictive and preventive interventions that have enhanced the role of laboratory medicine in health care delivering. However, the paradigm shift in the past 50 years has led to a gap between laboratory and clinic, with an increased risk of inappropriateness in test request and interpretation, as well as the consolidation of analytical work in focused factories and megastructurers oriented only toward achieving greater volumes, decreasing cost per test and generating a vision of laboratory services as simple commodities. A careful historical revision of the changing models for delivering laboratory services in the United States leads to the prediction that there are several reasons for counteracting the vision of clinical laboratory as a commodity, and restoring the true nature of laboratory services as an integral part of the diagnosis and therapy process. The present study, which reports on internal and external drivers for change, proposes an integrated vision of quality in laboratory medicine.
Nelson, Jonathan M.; Kinzel, Paul J.; McDonald, Richard R.; Schmeeckle, Mark
2016-01-01
Recently developed optical and videographic methods for measuring water-surface properties in a noninvasive manner hold great promise for extracting river hydraulic and bathymetric information. This paper describes such a technique, concentrating on the method of infrared videog- raphy for measuring surface velocities and both acoustic (laboratory-based) and laser-scanning (field-based) techniques for measuring water-surface elevations. In ideal laboratory situations with simple flows, appropriate spatial and temporal averaging results in accurate water-surface elevations and water-surface velocities. In test cases, this accuracy is sufficient to allow direct inversion of the governing equations of motion to produce estimates of depth and discharge. Unlike other optical techniques for determining local depth that rely on transmissivity of the water column (bathymetric lidar, multi/hyperspectral correlation), this method uses only water-surface information, so even deep and/or turbid flows can be investigated. However, significant errors arise in areas of nonhydrostatic spatial accelerations, such as those associated with flow over bedforms or other relatively steep obstacles. Using laboratory measurements for test cases, the cause of these errors is examined and both a simple semi-empirical method and computational results are presented that can potentially reduce bathymetric inversion errors.
Rohner, Fabian; Kangambèga, Marcelline O.; Khan, Noor; Kargougou, Robert; Garnier, Denis; Sanou, Ibrahima; Ouaro, Bertine D.; Petry, Nicolai; Wirth, James P.; Jooste, Pieter
2015-01-01
Background Iodine deficiency has important health and development consequences and the introduction of iodized salt as national programs has been a great public health success in the past decades. To render national salt iodization programs sustainable and ensure adequate iodization levels, simple methods to quantitatively assess whether salt is adequately iodized are required. Several methods claim to be simple and reliable, and are available on the market or are in development. Objective This work has validated the currently available quantitative rapid test kits (quantRTK) in a comparative manner for both their laboratory performance and ease of use in field settings. Methods Laboratory performance parameters (linearity, detection and quantification limit, intra- and inter-assay imprecision) were conducted on 5 quantRTK. We assessed inter-operator imprecision using salt of different quality along with the comparison of 59 salt samples from across the globe; measurements were made both in a laboratory and a field setting by technicians and non-technicians. Results from the quantRTK were compared against iodometric titration for validity. An ‘ease-of-use’ rating system was developed to identify the most suitable quantRTK for a given task. Results Most of the devices showed acceptable laboratory performance, but for some of the devices, use by non-technicians revealed poorer performance when working in a routine manner. Of the quantRTK tested, the iCheck® and I-Reader® showed most consistent performance and ease of use, and a newly developed paper-based method (saltPAD) holds promise if further developed. Conclusions User- and field-friendly devices are now available and the most appropriate quantRTK can be selected depending on the number of samples and the budget available. PMID:26401655
ERIC Educational Resources Information Center
Ibanez, Jorge G.; Mayen-Mondragon, Rodrigo; Moran-Moran, M. T.; Alatorre-Ordaz, Alejandro; Mattson, Bruce; Eskestrand, Scot
2005-01-01
Ozone is a powerful oxidant and disinfectant, which can be used to clean environment as well as obtain pure drinking water. A series of experiments to produce and test ozone with simple equipment and material are presented.
Osmosis in Poisoned Plant Cells.
ERIC Educational Resources Information Center
Tatina, Robert
1998-01-01
Describes two simple laboratory exercises that allow students to test hypotheses concerning the requirement of cell energy for osmosis. The first exercise involves osmotically-caused changes in the length of potato tubers and requires detailed quantitative observations. The second exercise involves osmotically-caused changes in turgor of Elodea…
Building Diversified Multiple Trees for classification in high dimensional noisy biomedical data.
Li, Jiuyong; Liu, Lin; Liu, Jixue; Green, Ryan
2017-12-01
It is common that a trained classification model is applied to the operating data that is deviated from the training data because of noise. This paper will test an ensemble method, Diversified Multiple Tree (DMT), on its capability for classifying instances in a new laboratory using the classifier built on the instances of another laboratory. DMT is tested on three real world biomedical data sets from different laboratories in comparison with four benchmark ensemble methods, AdaBoost, Bagging, Random Forests, and Random Trees. Experiments have also been conducted on studying the limitation of DMT and its possible variations. Experimental results show that DMT is significantly more accurate than other benchmark ensemble classifiers on classifying new instances of a different laboratory from the laboratory where instances are used to build the classifier. This paper demonstrates that an ensemble classifier, DMT, is more robust in classifying noisy data than other widely used ensemble methods. DMT works on the data set that supports multiple simple trees.
Identifying causes of laboratory turnaround time delay in the emergency department.
Jalili, Mohammad; Shalileh, Keivan; Mojtahed, Ali; Mojtahed, Mohammad; Moradi-Lakeh, Maziar
2012-12-01
Laboratory turnaround time (TAT) is an important determinant of patient stay and quality of care. Our objective is to evaluate laboratory TAT in our emergency department (ED) and to generate a simple model for identifying the primary causes for delay. We measured TATs of hemoglobin, potassium, and prothrombin time tests requested in the ED of a tertiary-care, metropolitan hospital during a consecutive one-week period. The time of different steps (physician order, nurse registration, blood-draw, specimen dispatch from the ED, specimen arrival at the laboratory, and result availability) in the test turnaround process were recorded and the intervals between these steps (order processing, specimen collection, ED waiting, transit, and within-laboratory time) and total TAT were calculated. Median TATs for hemoglobin and potassium were compared with those of the 1990 Q-Probes Study (25 min for hemoglobin and 36 min for potassium) and its recommended goals (45 min for 90% of tests). Intervals were compared according to the proportion of TAT they comprised. Median TATs (170 min for 132 hemoglobin tests, 225 min for 172 potassium tests, and 195.5 min for 128 prothrombin tests) were drastically longer than Q-Probes reported and recommended TATs. The longest intervals were ED waiting time and order processing. Laboratory TAT varies among institutions, and data are sparse in developing countries. In our ED, actions to reduce ED waiting time and order processing are top priorities. We recommend utilization of this model by other institutions in settings with limited resources to identify their own priorities for reducing laboratory TAT.
Richter, S. Helene; Garner, Joseph P.; Zipser, Benjamin; Lewejohann, Lars; Sachser, Norbert; Touma, Chadi; Schindler, Britta; Chourbaji, Sabine; Brandwein, Christiane; Gass, Peter; van Stipdonk, Niek; van der Harst, Johanneke; Spruijt, Berry; Võikar, Vootele; Wolfer, David P.; Würbel, Hanno
2011-01-01
In animal experiments, animals, husbandry and test procedures are traditionally standardized to maximize test sensitivity and minimize animal use, assuming that this will also guarantee reproducibility. However, by reducing within-experiment variation, standardization may limit inference to the specific experimental conditions. Indeed, we have recently shown in mice that standardization may generate spurious results in behavioral tests, accounting for poor reproducibility, and that this can be avoided by population heterogenization through systematic variation of experimental conditions. Here, we examined whether a simple form of heterogenization effectively improves reproducibility of test results in a multi-laboratory situation. Each of six laboratories independently ordered 64 female mice of two inbred strains (C57BL/6NCrl, DBA/2NCrl) and examined them for strain differences in five commonly used behavioral tests under two different experimental designs. In the standardized design, experimental conditions were standardized as much as possible in each laboratory, while they were systematically varied with respect to the animals' test age and cage enrichment in the heterogenized design. Although heterogenization tended to improve reproducibility by increasing within-experiment variation relative to between-experiment variation, the effect was too weak to account for the large variation between laboratories. However, our findings confirm the potential of systematic heterogenization for improving reproducibility of animal experiments and highlight the need for effective and practicable heterogenization strategies. PMID:21305027
ERIC Educational Resources Information Center
Scott, Alan
2013-01-01
A simple apparatus is described which serves as a materials testing laboratory. Bolts are placed in it and subjected to tensile and torsional stress while being tightened. The tensile and torsional stress and strain can be measured, which enables the determination of several mechanical properties of the bolt material, including Young's…
ERIC Educational Resources Information Center
School Science Review, 1981
1981-01-01
Presents a variety of laboratory procedures, discussions, and demonstrations including centripedal force apparatus, model ear drum, hot air balloons, air as a real substance, centering a ball, simple test tube rack, demonstration fire extinguisher, pin-hole camera, and guidelines for early primary science education (5-10 years) concepts and lesson…
EVALUATION OF MIXING ENERGY IN FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING
A U.S. Environmental Protection Agency (EPA) laboratory screening protocol for dispersant effectiveness consists of placing water, oil, and a dispersant in a flask and mixing the contents on an orbital shaker. Two flasks are being investigated, a simple Erlenmeyer (used in EPA's...
ERIC Educational Resources Information Center
HILL, EDWIN K.
AN EXPERIMENTAL POLYSENSORY SELF-INSTRUCTIONAL SYSTEM DESIGNED TO ASSIST STUDENTS IN ACQUIRING AND APPLYING KNOWLEDGE OF THE NATURE, CONVERSION, AND TRANSMISSION OF ELECTRICAL ENERGY AND OF PRINCIPLES OF SIMPLE EELECTRICAL CIRCUITS WAS DEVELOPED AND TESTED FOR EFFECTIVENESS. RELATED LABORATORY EXERCISES WERE AN INTEGRAL PART OF THE SYSTEM WHICH…
Watertight cataract incision closure using fibrin tissue adhesive.
Hovanesian, John A; Karageozian, Vicken H
2007-08-01
To determine whether a simple method for applying fibrin tissue adhesive to a clear corneal cataract incision can create a watertight seal. Laboratory investigation. Clear corneal cataract incisions were simulated in 8 eye-bank eyes. In 4 eyes, fibrin adhesive was applied to the incision in a simple manner; the other 4 eyes were controls with no adhesive. Each eye was tested under low pressure conditions to detect fluid ingress of India Ink on the eye's surface. The eyes were tested again with external compression to distort the incision to detect fluid egress. In the eyes with fibrin adhesive, there was no egress of fluid with incision distortion and no ingress of India Ink. In the 4 eyes without adhesive, there was ingress and egress of fluid. A simple method of applying fibrin adhesive to cataract incisions created a watertight seal.
ERIC Educational Resources Information Center
Tekbiyik, Ahmet; Ercan, Orhan
2015-01-01
Current study examined the effects of virtual and physical laboratory practices on students' conceptual achievement in the subject of electricity and their attitudes towards simple electric circuits. Two groups (virtual and physical) selected through simple random sampling was taught with web-aided material called "Electricity in Our…
Safety in the Chemical Laboratory: Laboratory Air Quality: Part I. A Concentration Model.
ERIC Educational Resources Information Center
Butcher, Samuel S.; And Others
1985-01-01
Offers a simple model for estimating vapor concentrations in instructional laboratories. Three methods are described for measuring ventilation rates, and the results of measurements in six laboratories are presented. The model should provide a simple screening tool for evaluating worst-case personal exposures. (JN)
Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L
2017-01-01
Background Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. Objectives We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Methods Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Results Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Conclusions Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. PMID:27193033
Evaluation of latex agglutination test (KAtex) for early diagnosis of kala-azar.
Ahsan, M M; Islam, M N; Mollah, A H; Hoque, M A; Hossain, M A; Begum, Z; Islam, M T
2010-07-01
Kala-azar is one of the major public health problem in Bangladesh. But the diagnosis of the problem often is difficult, unusual and time consuming, a simple, noninvasive, easy to perform, reliable and rapid diagnostic test has been a long-felt need of the clinicians. Therefore, the present study was conducted to see the sensitivity and specificity of Latex Agglutination test (KAtex) to detect leishmanial antigen from urine of kala-azar cases. The study was carried out in the department of Paediatrics, Mymensingh Medical College and Hospital, Bangladesh during July to December, 2008. A total of 100 urine samples were collected of which 50 were confirmed kala-azar cases and 50 were age and sex matched controls. Out of 50 kala-azar cases 47 showed positive result of KAtex. The test was also positive in 01 out of 30 healthy controls. None of the febrile controls was positive by KAtex. The sensitivity, specificity, positive predictive value and negative predictive value of the test using presence of LD bodies in splenic and/or bone marrow aspirate as gold standard were 94%, 98%, 97.91% and 94.23% respectively. KAtex is simple, noninvasive, easy to perform, rapid and reliable test for diagnosing kala-azar in endemic area and useful for small, less equipped laboratories as well as for the laboratories with better facilities.
Robert L. Geimer; Robert A. Follensbee; Alfred W. Christiansen; James A. Koutsky; George E. Myers
1990-01-01
Currently, thermosetting adhesives are characterized by physical andchemical features such as viscosity, solids content, pH, and molecular distribution, and their reaction in simple gel tests. Synthesis of a new resin for a particular application is usually accompanied by a series of empirical laboratory and plant trials. The purpose of the research outlined in this...
Scottish Schools Science Equipment Research Centre.
ERIC Educational Resources Information Center
1972
This newsletter is composed of brief notes in the various areas of science. Biology Notes include hazards of tasting Phenylthiocarbamide in laboratory experiments, the use of Albustic and Clinistix test papers for protein and glucose determinations, the measurement of the respiratory quotient, and the construction of a simple respirometer. Physics…
A Novel W-Tube for Microscale Experiments in Chemistry
ERIC Educational Resources Information Center
Gupta, H. O.
2007-01-01
A simple W-shaped apparatus was developed by bending glass tubing to contain all of the chemicals involved and to limit the quantities to microscale. The W-tubes were tested by the teachers and students from a few schools to demonstrate its great utility and convenience in microscale chemistry laboratory.
[Microbiology--laboratory examinations for bacterias].
Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi
2002-11-01
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
Virtual and remote robotic laboratory using EJS, MATLAB and LabVIEW.
Chaos, Dictino; Chacón, Jesús; Lopez-Orozco, Jose Antonio; Dormido, Sebastián
2013-02-21
This paper describes the design and implementation of a virtual and remote laboratory based on Easy Java Simulations (EJS) and LabVIEW. The main application of this laboratory is to improve the study of sensors in Mobile Robotics, dealing with the problems that arise on the real world experiments. This laboratory allows the user to work from their homes, tele-operating a real robot that takes measurements from its sensors in order to obtain a map of its environment. In addition, the application allows interacting with a robot simulation (virtual laboratory) or with a real robot (remote laboratory), with the same simple and intuitive graphical user interface in EJS. Thus, students can develop signal processing and control algorithms for the robot in simulation and then deploy them on the real robot for testing purposes. Practical examples of application of the laboratory on the inter-University Master of Systems Engineering and Automatic Control are presented.
Virtual and Remote Robotic Laboratory Using EJS, MATLAB and Lab VIEW
Chaos, Dictino; Chacón, Jesús; Lopez-Orozco, Jose Antonio; Dormido, Sebastián
2013-01-01
This paper describes the design and implementation of a virtual and remote laboratory based on Easy Java Simulations (EJS) and LabVIEW. The main application of this laboratory is to improve the study of sensors in Mobile Robotics, dealing with the problems that arise on the real world experiments. This laboratory allows the user to work from their homes, tele-operating a real robot that takes measurements from its sensors in order to obtain a map of its environment. In addition, the application allows interacting with a robot simulation (virtual laboratory) or with a real robot (remote laboratory), with the same simple and intuitive graphical user interface in EJS. Thus, students can develop signal processing and control algorithms for the robot in simulation and then deploy them on the real robot for testing purposes. Practical examples of application of the laboratory on the inter-University Master of Systems Engineering and Automatic Control are presented. PMID:23429578
The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays.
Zhan, Li; Guo, Shuang-Zhuang; Song, Fayi; Gong, Yan; Xu, Feng; Boulware, David R; McAlpine, Michael C; Chan, Warren C W; Bischof, John C
2017-12-13
Rapid, simple, and cost-effective diagnostics are needed to improve healthcare at the point of care (POC). However, the most widely used POC diagnostic, the lateral flow immunoassay (LFA), is ∼1000-times less sensitive and has a smaller analytical range than laboratory tests, requiring a confirmatory test to establish truly negative results. Here, a rational and systematic strategy is used to design the LFA contrast label (i.e., gold nanoparticles) to improve the analytical sensitivity, analytical detection range, and antigen quantification of LFAs. Specifically, we discovered that the size (30, 60, or 100 nm) of the gold nanoparticles is a main contributor to the LFA analytical performance through both the degree of receptor interaction and the ultimate visual or thermal contrast signals. Using the optimal LFA design, we demonstrated the ability to improve the analytical sensitivity by 256-fold and expand the analytical detection range from 3 log 10 to 6 log 10 for diagnosing patients with inflammatory conditions by measuring C-reactive protein. This work demonstrates that, with appropriate design of the contrast label, a simple and commonly used diagnostic technology can compete with more expensive state-of-the-art laboratory tests.
Development of Technologies for Early Detection and Stratification of Breast Cancer
2015-10-01
fatal disease progression, or in the cases of over-treatment, unnecessary physical and emotional trauma.4 ELISA, the most common immunoassay for...laboratory to discover new biomarkers that meet these requirements within serum so that a simple blood test can be implemented. We are also working to...microspheres and tested first on standard samples. Assay performance characteristics will be determined to ascertain that they will address
Huber, A R; Méndez, A; Brunner-Agten, S
2013-01-01
Automatia, an ancient Greece goddess of luck who makes things happen by themselves and on her own will without human engagement, is present in our daily life in the medical laboratory. Automation has been introduced and perfected by clinical chemistry and since then expanded into other fields such as haematology, immunology, molecular biology and also coagulation testing. The initial small and relatively simple standalone instruments have been replaced by more complex systems that allow for multitasking. Integration of automated coagulation testing into total laboratory automation has become possible in the most recent years. Automation has many strengths and opportunities if weaknesses and threats are respected. On the positive side, standardization, reduction of errors, reduction of cost and increase of throughput are clearly beneficial. Dependence on manufacturers, high initiation cost and somewhat expensive maintenance are less favourable factors. The modern lab and especially the todays lab technicians and academic personnel in the laboratory do not add value for the doctor and his patients by spending lots of time behind the machines. In the future the lab needs to contribute at the bedside suggesting laboratory testing and providing support and interpretation of the obtained results. The human factor will continue to play an important role in testing in haemostasis yet under different circumstances.
Genotypic variability enhances the reproducibility of an ecological study.
Milcu, Alexandru; Puga-Freitas, Ruben; Ellison, Aaron M; Blouin, Manuel; Scheu, Stefan; Freschet, Grégoire T; Rose, Laura; Barot, Sebastien; Cesarz, Simone; Eisenhauer, Nico; Girin, Thomas; Assandri, Davide; Bonkowski, Michael; Buchmann, Nina; Butenschoen, Olaf; Devidal, Sebastien; Gleixner, Gerd; Gessler, Arthur; Gigon, Agnès; Greiner, Anna; Grignani, Carlo; Hansart, Amandine; Kayler, Zachary; Lange, Markus; Lata, Jean-Christophe; Le Galliard, Jean-François; Lukac, Martin; Mannerheim, Neringa; Müller, Marina E H; Pando, Anne; Rotter, Paula; Scherer-Lorenzen, Michael; Seyhun, Rahme; Urban-Mead, Katherine; Weigelt, Alexandra; Zavattaro, Laura; Roy, Jacques
2018-02-01
Many scientific disciplines are currently experiencing a 'reproducibility crisis' because numerous scientific findings cannot be repeated consistently. A novel but controversial hypothesis postulates that stringent levels of environmental and biotic standardization in experimental studies reduce reproducibility by amplifying the impacts of laboratory-specific environmental factors not accounted for in study designs. A corollary to this hypothesis is that a deliberate introduction of controlled systematic variability (CSV) in experimental designs may lead to increased reproducibility. To test this hypothesis, we had 14 European laboratories run a simple microcosm experiment using grass (Brachypodium distachyon L.) monocultures and grass and legume (Medicago truncatula Gaertn.) mixtures. Each laboratory introduced environmental and genotypic CSV within and among replicated microcosms established in either growth chambers (with stringent control of environmental conditions) or glasshouses (with more variable environmental conditions). The introduction of genotypic CSV led to 18% lower among-laboratory variability in growth chambers, indicating increased reproducibility, but had no significant effect in glasshouses where reproducibility was generally lower. Environmental CSV had little effect on reproducibility. Although there are multiple causes for the 'reproducibility crisis', deliberately including genetic variability may be a simple solution for increasing the reproducibility of ecological studies performed under stringently controlled environmental conditions.
SOLPOL: A Solar Polarimeter for Hard X-Rays and Gamma-Rays
NASA Technical Reports Server (NTRS)
McConnell, Michael L.
1999-01-01
Th goal of this project was to continue the development of a hard X-ray polarimeter for studying solar flares. In earlier work (funded by a previous SR&T grant), we had already achieved several goals, including the following: 1) development of a means of producing a polarized radiation source in the lab that could be used for prototype development; 2) demonstrated the basic Compton scatter polarimeter concept using a simple laboratory setup; 3) used the laboratory results to verify our Monte Carlo simulations; and 4) investigated various detector technologies that could be incorporated into the polarimeter design. For the current one-year program, we wanted to fabricate and test a laboratory science model based on our SOLPOL (Solar Polarimeter) design. The long-term goal of this effort is to develop and test a prototype design that could be used to study flare emissions from either a balloon- or space-borne platform. The current program has achieved its goal of fabricating and testing a science model of the SOLPOL design, although additional testing of the design (and detailed comparison with Monte Carlo simulations) is still desired. This one-year program was extended by six months (no-cost extension) to cover the summer of 1999, when undergraduate student support was available to complete some of the laboratory testing.
A Simple Laboratory Exercise Illustrating Active Transport in Yeast Cells.
ERIC Educational Resources Information Center
Stambuk, Boris U.
2000-01-01
Describes a simple laboratory activity illustrating the chemiosmotic principles of active transport in yeast cells. Demonstrates the energy coupling mechanism of active a-glucoside uptake by Saccaromyces cerevisiae cells with a colorimetric transport assay using very simple equipment. (Contains 22 references.) (Author/YDS)
A simple pore water hydrogen diffusion syringe sampler
Vroblesky, D.A.; Chapelle, F.H.; Bradley, P.M.
2007-01-01
Molecular hydrogen (H2) is an important intermediate product and electron donor in microbial metabolism. Concentrations of dissolved H 2 are often diagnostic of the predominant terminal electron-accepting processes in ground water systems or aquatic sediments. H2 concentrations are routinely measured in ground water monitoring wells but are rarely measured in saturated aquatic sediments due to a lack of simple and practical sampling methods. This report describes the design and development (including laboratory and field testing) of a simple, syringe-based H 2 sampler in (1) saturated, riparian sediments, (2) surface water bed sediments, and (3) packed intervals of a fractured bedrock borehole that are inaccessible by standard pumped methods. ?? 2007 National Ground Water Association.
UV Radiation Damage and Bacterial DNA Repair Systems
ERIC Educational Resources Information Center
Zion, Michal; Guy, Daniel; Yarom, Ruth; Slesak, Michaela
2006-01-01
This paper reports on a simple hands-on laboratory procedure for high school students in studying both radiation damage and DNA repair systems in bacteria. The sensitivity to ultra-violet (UV) radiation of both "Escherichia coli" and "Serratia marcescens" is tested by radiating them for varying time periods. Two growth temperatures are used in…
ERIC Educational Resources Information Center
Wilson, Mark V.; Wilson, Erin
2017-01-01
In this work we describe an authentic performance project for Instrumental Analysis in which students designed, built, and tested spectrophotometers made from simple components. The project addressed basic course content such as instrument design principles, UV-vis spectroscopy, and spectroscopic instrument components as well as skills such as…
An Experiment on a Physical Pendulum and Steiner's Theorem
ERIC Educational Resources Information Center
Russeva, G. B.; Tsutsumanova, G. G.; Russev, S. C.
2010-01-01
Introductory physics laboratory curricula usually include experiments on the moment of inertia, the centre of gravity, the harmonic motion of a physical pendulum, and Steiner's theorem. We present a simple experiment using very low cost equipment for investigating these subjects in the general case of an asymmetrical test body. (Contains 3 figures…
Safety in the Chemical Laboratory
ERIC Educational Resources Information Center
Coffee, Robert D.
1972-01-01
The author discusses a system for establishing the relative potential of a chemical to release energy suddenly and to indicate release. This system is applicable to chemical storage and transportation. The system is based upon three simple tests requiring a minimum sample (1 go or 1 ml): (1) computation, (2) impact sensitivity, and (3) thermal…
NASA Astrophysics Data System (ADS)
Johnston, Marty; Jalkio, Jeffrey
2013-04-01
By the time students have reached the intermediate level physics courses they have been exposed to a broad set of analytical, experimental, and computational skills. However, their ability to independently integrate these skills into the study of a physical system is often weak. To address this weakness and assess their understanding of the underlying physical concepts we have introduced laboratory homework into lecture based, junior level theoretical mechanics and electromagnetics courses. A laboratory homework set replaces a traditional one and emphasizes the analysis of a single system. In an exercise, students use analytical and computational tools to predict the behavior of a system and design a simple measurement to test their model. The laboratory portion of the exercises is straight forward and the emphasis is on concept integration and application. The short student reports we collect have revealed misconceptions that were not apparent in reviewing the traditional homework and test problems. Work continues on refining the current problems and expanding the problem sets.
Microbiologic Testing for 503A Sterile-Compounding Pharmacies.
Mixon, William; Roth, Abby
2017-01-01
Compounding pharmacists must ensure that the sterile preparations they dispense are free of microbiologic contamination. Working in a cleanroom under controlled conditions (proper differential air pressure, temperature, and humidity; acceptable levels of viable and nonviable airborne particles and surface counts, etc.) and testing the efficacy of cleaning and disinfecting practices via environmental monitoring (viable-air and surface testing, glove-fingertip-thumb testing, etc.) are essential to preparing contamination-free medications. Sterile-compounding pharmacists must understand how to monitor their cleanroom environment and, if they perform testing in house, to interpret the results of simple microbiologic tests (a skill helpful even when tests are outsourced to a contract laboratory). In this article, which pertains to 503A sterile compounding, and is based on the current version of United States Pharmacopeia (USP) Chapter <797>, basic concepts in microbiology and the microbial tests that can be performed and interpreted in house and those that must be outsourced are discussed. Streamlining communication with contract laboratory personnel is reviewed. Requirements for an inhouse microbiology laboratory are presented, and the advantages and disadvantages of inhouse and outsourced testing are examined. A list of suggested reading is provided for easy reference. In a subsequent article, environmental monitoring and analysis will be addressed in detail. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Halbach, Udo; Burkhardt, Heinz Jürgen
1972-09-01
Laboratory populations of the rotifer Brachionus calyciflorus were cultured at different temperatures (25, 20, 15°C) but otherwise at constant conditions. The population densities showed relatively constant oscillations (Figs. 1 to 3A-C). Amplitudes and frequencies of the oscillations were positively correlated with temperature (Table 1). A test was made, whether the logistic growth function with simple time lag is able to describe the population curves. There are strong similarities between the simulations (Figs. 1-3E) and the real population dynamics if minor adjustments of the empirically determined parameters are made. There-fore it is suggested that time lags are responsible for the observed oscillations. However, the actual time lags probably do not act in the simple manner of the model, because birth and death rates react with different time lags, and both parameters are dependent on individual age and population density. A more complex model, which incorporates these modifications, should lead to a more realistic description of the observed oscillations.
Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L
2017-06-01
Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji
2013-08-01
We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.
Schroeder, Scott R; Salomon, Meghan M; Galanter, William L; Schiff, Gordon D; Vaida, Allen J; Gaunt, Michael J; Bryson, Michelle L; Rash, Christine; Falck, Suzanne; Lambert, Bruce L
2017-05-01
Drug name confusion is a common type of medication error and a persistent threat to patient safety. In the USA, roughly one per thousand prescriptions results in the wrong drug being filled, and most of these errors involve drug names that look or sound alike. Prior to approval, drug names undergo a variety of tests to assess their potential for confusability, but none of these preapproval tests has been shown to predict real-world error rates. We conducted a study to assess the association between error rates in laboratory-based tests of drug name memory and perception and real-world drug name confusion error rates. Eighty participants, comprising doctors, nurses, pharmacists, technicians and lay people, completed a battery of laboratory tests assessing visual perception, auditory perception and short-term memory of look-alike and sound-alike drug name pairs (eg, hydroxyzine/hydralazine). Laboratory test error rates (and other metrics) significantly predicted real-world error rates obtained from a large, outpatient pharmacy chain, with the best-fitting model accounting for 37% of the variance in real-world error rates. Cross-validation analyses confirmed these results, showing that the laboratory tests also predicted errors from a second pharmacy chain, with 45% of the variance being explained by the laboratory test data. Across two distinct pharmacy chains, there is a strong and significant association between drug name confusion error rates observed in the real world and those observed in laboratory-based tests of memory and perception. Regulators and drug companies seeking a validated preapproval method for identifying confusing drug names ought to consider using these simple tests. By using a standard battery of memory and perception tests, it should be possible to reduce the number of confusing look-alike and sound-alike drug name pairs that reach the market, which will help protect patients from potentially harmful medication errors. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Does linear separability really matter? Complex visual search is explained by simple search
Vighneshvel, T.; Arun, S. P.
2013-01-01
Visual search in real life involves complex displays with a target among multiple types of distracters, but in the laboratory, it is often tested using simple displays with identical distracters. Can complex search be understood in terms of simple searches? This link may not be straightforward if complex search has emergent properties. One such property is linear separability, whereby search is hard when a target cannot be separated from its distracters using a single linear boundary. However, evidence in favor of linear separability is based on testing stimulus configurations in an external parametric space that need not be related to their true perceptual representation. We therefore set out to assess whether linear separability influences complex search at all. Our null hypothesis was that complex search performance depends only on classical factors such as target-distracter similarity and distracter homogeneity, which we measured using simple searches. Across three experiments involving a variety of artificial and natural objects, differences between linearly separable and nonseparable searches were explained using target-distracter similarity and distracter heterogeneity. Further, simple searches accurately predicted complex search regardless of linear separability (r = 0.91). Our results show that complex search is explained by simple search, refuting the widely held belief that linear separability influences visual search. PMID:24029822
Interpretation of diagnostic data: 5. How to do it with simple maths.
1983-11-01
The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator.
Interpretation of diagnostic data: 5. How to do it with simple maths.
1983-01-01
The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator. PMID:6671182
Measuring the mechanical behavior of paperboard in a changing humidity environment
Dennis E. Gunderson; John M. Considine
1986-01-01
âBoth the strength and stability of compressively loaded paperboard are known to be adversely affected by cyclic changes in relative humidity. Current research at the Forest Products Laboratory (FPL) seeks to observe and explain this phenomenon and to develop a simple, practical test to determine allowable "working loads" in cyclicmoisture environments. A new...
Recycled fiber quality from a laboratory-scale blade separator/blend
Bei-Hong Liang; Stephen M. Shaler; Laurence Mott; Leslie Groom
1994-01-01
A simple and inexpensive fiber separator/blender was developed to generate useful secondary fibers from hydropulped waste paper. Processing wet hydropulped fiber resulted in a furnish with no change in average fiber length in three out of four types of recycled fibers tested. In all cases, the Canadian Standard freeness increased after processing compared to...
Recycled fiber quality from a laboratory-scale blade separator/blender
Bei-Hong Liang; Stephen M. Shaler; Laurence Mott; Leslie Groom
1994-01-01
A simple and inexpensive fiber separator/blender was developed to generate useful secondary fibers from hydropulped waste paper. Processing wet hydropulped fiber resulted in a furnish with no change in average fiber length in three out of four types of recycled fibers tested. In all cases, the canadian standard freeness increased after processing compared to...
Nondestructive assessment of timber bridges using a vibration-based method
Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw
2005-01-01
This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...
Definition of Throw-Away Detectors (TADs) and VLF antenna for the AMPS laboratory
NASA Technical Reports Server (NTRS)
Koons, H. C.; Fennell, J. F.
1975-01-01
A Throw Away Detector (TAD)/subsatellite to be used as an experiment platform for the test flights to map the EMI from the shuttle and during the AMPS science flights is defined. A range of instrument platforms of varying capabilities is examined with emphasis on the EMI test vehicle. The operational support requirements of TAD/subsatellites are determined. The throw away detector is envisioned as a simple instrument package for supporting specific experiments.
The History and Implications of Design Standards for Underwater Breathing Apparatus - 1954 to 2015
2015-02-11
respiratory loading using both simple models of fluid mechanics and experimental evidence. An understanding of the influence of both respiratory ventilatory... fluid dynamics of flow in divers’ airways. It allows testing laboratories to make maximum use of all of their testing data, and lo present that data in...tireless efforts of numerous military divers at Navy Experimental Diving Unit in Panama City, FL and Naval Medical Research Institute, Bethesda, MD
Simple Statistical Model to Quantify Maximum Expected EMC in Spacecraft and Avionics Boxes
NASA Technical Reports Server (NTRS)
Trout, Dawn H.; Bremner, Paul
2014-01-01
This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. Test and model data correlation is shown. In addition, this presentation shows application of the power balance and extention of this method to predict the variance and maximum exptected mean of the E-field data. This is valuable for large scale evaluations of transmission inside cavities.
Hybrid nanosensor for colorimetric and ultrasensitive detection of nuclease contaminations
NASA Astrophysics Data System (ADS)
Cecere, Paola; Valentini, Paola; Pompa, Pier Paolo
2016-04-01
Nucleases are ubiquitous enzymes that degrade DNA or RNA, thus they can prejudice the good outcome of molecular biology experiments involving nucleic acids. We propose a colorimetric test for the naked-eye detection of nuclease contaminations. The system uses an hybrid nanosensor, based on gold nanoparticles functionalized with DNA probes. Our assay is rapid, instrument-free, simple and low-cost. Moreover, it reaches sensitivity equal or better than those of commercial kits, and presents a lot of advantageous aspects. Therefore, it is very competitive, with a real market potential. This test will be relevant in routine process monitoring in scientific laboratories, and in quality control in clinical laboratories and industrial processes, allowing the simultaneous detection of nucleases with different substrate specificities and large-scale screening.
Bell's Theorem and Einstein's `Spooky Actions' from a Simple Thought Experiment
NASA Astrophysics Data System (ADS)
Kuttner, Fred; Rosenblum, Bruce
2010-02-01
In 1964 John Bell proved a theorem2 allowing the experimental test of whether what Einstein derided as "spooky actions at a distance" actually exist. We will see that they do. Bell's theorem can be displayed with a simple, nonmathematical thought experiment suitable for a physics course at any level. And a simple, semi-classical derivation of the quantum theory result can be given for physics students. These entanglement phenomena are today applied in industrial laboratories and are increasingly discussed in the popular literature. Unfortunately, they are also misappropriated by the purveyors of pseudoscience, something physicists have a responsibility to address.3 Students can be intrigued by the quantum strangeness physics has encountered at a boundary of our discipline.
Laser Speckle Photography: Some Simple Experiments for the Undergraduate Laboratory.
ERIC Educational Resources Information Center
Bates, B.; And Others
1986-01-01
Describes simple speckle photography experiments which are easy to set up and require only low cost standard laboratory equipment. Included are procedures for taking single, double, and multiple exposures. (JN)
Overview of software development at the parabolic dish test site
NASA Technical Reports Server (NTRS)
Miyazono, C. K.
1985-01-01
The development history of the data acquisition and data analysis software is discussed. The software development occurred between 1978 and 1984 in support of solar energy module testing at the Jet Propulsion Laboratory's Parabolic Dish Test Site, located within Edwards Test Station. The development went through incremental stages, starting with a simple single-user BASIC set of programs, and progressing to the relative complex multi-user FORTRAN system that was used until the termination of the project. Additional software in support of testing is discussed including software in support of a meteorological subsystem and the Test Bed Concentrator Control Console interface. Conclusions and recommendations for further development are discussed.
Factors Influencing Ball-Player Impact Probability in Youth Baseball
Matta, Philip A.; Myers, Joseph B.; Sawicki, Gregory S.
2015-01-01
Background: Altering the weight of baseballs for youth play has been studied out of concern for player safety. Research has shown that decreasing the weight of baseballs may limit the severity of both chronic arm and collision injuries. Unfortunately, reducing the weight of the ball also increases its exit velocity, leaving pitchers and nonpitchers with less time to defend themselves. The purpose of this study was to examine impact probability for pitchers and nonpitchers. Hypothesis: Reducing the available time to respond by 10% (expected from reducing ball weight from 142 g to 113 g) would increase impact probability for pitchers and nonpitchers, and players’ mean simple response time would be a primary predictor of impact probability for all participants. Study Design: Nineteen subjects between the ages of 9 and 13 years performed 3 experiments in a controlled laboratory setting: a simple response time test, an avoidance response time test, and a pitching response time test. Methods: Each subject performed these tests in order. The simple reaction time test tested the subjects’ mean simple response time, the avoidance reaction time test tested the subjects’ ability to avoid a simulated batted ball as a fielder, and the pitching reaction time test tested the subjects’ ability to avoid a simulated batted ball as a pitcher. Results: Reducing the weight of a standard baseball from 142 g to 113 g led to a less than 5% increase in impact probability for nonpitchers. However, the results indicate that the impact probability for pitchers could increase by more than 25%. Conclusion: Pitching may greatly increase the amount of time needed to react and defend oneself from a batted ball. Clinical Relevance: Impact injuries to youth baseball players may increase if a 113-g ball is used. PMID:25984261
ERIC Educational Resources Information Center
Jaakkola, T.; Nurmi, S.
2008-01-01
Computer simulations and laboratory activities have been traditionally treated as substitute or competing methods in science teaching. The aim of this experimental study was to investigate if it would be more beneficial to combine simulation and laboratory activities than to use them separately in teaching the concepts of simple electricity. Based…
An Operationally Simple Sonogashira Reaction for an Undergraduate Organic Chemistry Laboratory Class
ERIC Educational Resources Information Center
Cranwell, Philippa B.; Peterson, Alexander M.; Littlefield, Benjamin T. R.; Russell, Andrew T.
2015-01-01
An operationally simple, reliable, and cheap Sonogashira reaction suitable for an undergraduate laboratory class that can be completed within a day-long (8 h) laboratory session has been developed. Cross-coupling is carried out between 2-methyl-3-butyn-2-ol and various aryl iodides using catalytic amounts of bis(triphenylphosphine)palladium(II)…
NASA Astrophysics Data System (ADS)
Honke, Michael L.; Bidinosti, Christopher P.
2018-06-01
We describe a very simple experiment that utilizes standard laboratory equipment to measure the electromagnetic response of a metallic sphere exposed to a uniform ac magnetic field. Measurements were made for a variety of non-magnetic and magnetic metals, and in all cases the results fit very well with theory over the four orders of frequency (25 Hz to 102 kHz) explored here. Precise values of magnetic permeability and electrical conductivity can be extracted from fits to the data given the sphere radius only. The same apparatus is also used to explore the effects of geometry on eddy current generation as well as to demonstrate non-destructive testing through measurements on coins of different composition.
Correlation of Mixture Temperature Data Obtained from Bare Intake-manifold Thermocouples
NASA Technical Reports Server (NTRS)
White, H. Jack; Gammon, Goldie L
1946-01-01
A relatively simple equation has been found to express with fair accuracy, variation in manifold-charge temperature with charge in engine operating conditions. This equation and associated curves have been checked by multi cylinder-engine data, both test stand and flight, over a wide range of operating conditions. Average mixture temperatures, predicted by the equations of this report, agree reasonably well with results within the same range of carburetor-air temperatures from laboratories and test stands other than the NACA.
The role of postictal laboratory blood analyses in the diagnosis and prognosis of seizures.
Nass, Robert D; Sassen, Robert; Elger, Christian E; Surges, Rainer
2017-04-01
Epileptic seizures (ES) lead to alterations in the blood laboratory values and reflect changes in different organ systems. Here, we review the diagnostic and prognostic value of various blood laboratory values within the context of epilepsy. Narrative review and literature search on PubMed using the term, "seizure" and various laboratory values. Laboratory markers can help clinicians determine whether an unwitnessed event was more likely to be epileptic or non-epileptic. Prolactin testing helps differentiate ES from psychogenic non-epileptic seizures (PNES) in adults and adolescents, and is associated with high specificity and moderate sensitivity. Elevations in the creatine kinase (CK) levels are common after generalized tonic-clonic seizures (GTCS) and display high specificity and moderate sensitivity. Metabolic markers such as ammonia and lactate may have diagnostic potential for postictal blood tests. Analyzing blood postictally is important for identifying the cause of the symptomatic seizures due to endocrine, metabolic, toxic or infectious etiologies. Finally, laboratory analyses are used for identifying patients who are at risk for developing rare, threatening complications such as rhabdomyolysis, acute renal failure (ARF) or cardiomyopathy. Presently, no postictal laboratory values can definitively prove or rule out the diagnosis of an epileptic seizure. For seizures with unknown causes, simple blood tests can be a valuable aid for quickly defining the etiology, particularly with certain metabolic and toxic encephalopathies. For this reason, CK, electrolytes, creatinine, liver and renal function tests should be measured on at least one occasion. Further research is needed in order to identify new biomarkers that improve the diagnosis and prognosis of seizures and seizure-related complications. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Nondestructive assessment of single-span timber bridges using a vibration- based method
Xiping Wang; James P. Wacker; Angus M. Morison; John W. Forsman; John R. Erickson; Robert J. Ross
2005-01-01
This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...
ERIC Educational Resources Information Center
Digilov, Rafael M.
2008-01-01
We describe a simple and very inexpensive undergraduate laboratory experiment for fast determination of Young's modulus at moderate temperatures with the aid of a force sensor. A strip-shaped specimen rigidly bolted to the force sensor forms a clamped-free cantilever beam. Placed in a furnace, it is subjected to free-bending vibrations followed by…
Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro
2016-01-01
Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.
ERIC Educational Resources Information Center
Gron, Liz U.; Bradley, Shelly B.; McKenzie, Jennifer R.; Shinn, Sara E.; Teague, M. Warfield
2013-01-01
This paper presents the use of simple, outcome-based assessment tools to design and evaluate the first semester of a new introductory laboratory program created to teach green analytical chemistry using environmental samples. This general chemistry laboratory program, like many introductory courses, has a wide array of stakeholders within and…
Laboratory practice at the periphery in developing countries.
Lewis, S M
2002-08-01
An effective national health service structure requires a comprehensive programme for primary health care in peripheral and rural areas. This is especially important in under-resourced countries where facilities are sparse, the population is widely dispersed and transport is limited. Haematology has a key role in diagnosis and patient management by selecting tests for their clinical relevance and utility for the specific circumstances, and ensuring their technical reliability when used in health clinics and point-of-care testing. WHO has proposed a basic menu of tests in three categories: (a) tests such as haemoglobin screen which can be performed by nurses, midwives, health-aides or community doctors, (b) tests such as haemoglobinometry, microhaematocrit and microscopic examination of stained preparations which can be performed by a technician or laboratory assistant in a health centre, (c) tests requiring greater technical expertise of a laboratory technician or trained doctor. The peripheral health clinics and district laboratories must be familiar with the guidelines on standardized methods for collecting and storing specimens and transporting them to a regional laboratory or a reference centre. A training syllabus should be provided at the health centres and district laboratories, and this should include on-site instruction from supervisors and access to training manuals and distance-learning material. A co-ordinated programme of quality assurance and standardization of test methods should be established by a reference centre or national health authority with a network which encompasses all laboratories and health clinics undertaking any tests. Each regional laboratory should foster lower level laboratories or clinics within its neighbourhood. Of particular concern is the reliable diagnosis and management of anaemia. WHO reports indicate that 40% of the world population suffer from anaemia, especially affecting pregnant women, and a high proportion of infants and children in developing countries. The Haemoglobin Colour Scale (HCS) was recently developed for WHO as a simple, cheap and portable device which reads haemoglobin within 1 g/dl of the true value. It has been validated in a number of studies and is now manufactured commercially in accordance with WHO specifications under control of a WHO Collaborating Centre. It has an important potential role in the resource-limited environment where anaemia screening presently usually depends on unreliable clinical examination.
Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.
ERIC Educational Resources Information Center
Pike, R. M.; And Others
1986-01-01
Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)
Chin, Ephrem L H; da Silva, Cristina; Hegde, Madhuri
2013-02-19
Detecting mutations in disease genes by full gene sequence analysis is common in clinical diagnostic laboratories. Sanger dideoxy terminator sequencing allows for rapid development and implementation of sequencing assays in the clinical laboratory, but it has limited throughput, and due to cost constraints, only allows analysis of one or at most a few genes in a patient. Next-generation sequencing (NGS), on the other hand, has evolved rapidly, although to date it has mainly been used for large-scale genome sequencing projects and is beginning to be used in the clinical diagnostic testing. One advantage of NGS is that many genes can be analyzed easily at the same time, allowing for mutation detection when there are many possible causative genes for a specific phenotype. In addition, regions of a gene typically not tested for mutations, like deep intronic and promoter mutations, can also be detected. Here we use 20 previously characterized Sanger-sequenced positive controls in disease-causing genes to demonstrate the utility of NGS in a clinical setting using standard PCR based amplification to assess the analytical sensitivity and specificity of the technology for detecting all previously characterized changes (mutations and benign SNPs). The positive controls chosen for validation range from simple substitution mutations to complex deletion and insertion mutations occurring in autosomal dominant and recessive disorders. The NGS data was 100% concordant with the Sanger sequencing data identifying all 119 previously identified changes in the 20 samples. We have demonstrated that NGS technology is ready to be deployed in clinical laboratories. However, NGS and associated technologies are evolving, and clinical laboratories will need to invest significantly in staff and infrastructure to build the necessary foundation for success.
Serological diagnosis of brucellosis.
Nielsen, K; Yu, W L
2010-01-01
To present a review and to describe the most widely used laboratory tests for serology diagnosis of brucellosis along with their pros and cons. Review the recent literature on brucellosis serology diagnostic tests. The choice of the testing strategy depends on the prevailing brucellosis epidemiological situation and the goal of testing. The 'gold standard' for the diagnosis of brucellosis is isolation and identification of the causative bacterium, a member of Brucella sp. Isolation of Brucella sp. requires high security laboratory facilities (biological containment level 3), highly skilled personnel, an extended turnaround time for results and it is considered a hazardous procedure. Hence brucellosis is generally diagnosed by detection of an elevated level of antibody in serum or other body fluid. This is a presumptive diagnosis as other microorganisms and perhaps environmental factors can also cause increased antibody levels. A large number of serological tests for brucellosis have been devised over the 100+ years since its initial isolation, starting with a simple agglutination test and progressing to sophisticated primary binding assays available today. However, no test devised to date is 100% accurate so generally serological diagnosis consists of testing sera by several tests, usually a screening test of high sensitivity, followed by a confirmatory test of high specificity.
Gene Polymorphism Studies in a Teaching Laboratory
NASA Astrophysics Data System (ADS)
Shultz, Jeffry
2009-02-01
I present a laboratory procedure for illustrating transcription, post-transcriptional modification, gene conservation, and comparative genetics for use in undergraduate biology education. Students are individually assigned genes in a targeted biochemical pathway, for which they design and test polymerase chain reaction (PCR) primers. In this example, students used genes annotated for the steroid biosynthesis pathway in soybean. The authoritative Kyoto encyclopedia of genes and genomes (KEGG) interactive database and other online resources were used to design primers based first on soybean expressed sequence tags (ESTs), then on ESTs from an alternate organism if soybean sequence was unavailable. Students designed a total of 50 gene-based primer pairs (37 soybean, 13 alternative) and tested these for polymorphism state and similarity between two soybean and two pea lines. Student assessment was based on acquisition of laboratory skills and successful project completion. This simple procedure illustrates conservation of genes and is not limited to soybean or pea. Cost per student estimates are included, along with a detailed protocol and flow diagram of the procedure.
Implementing self sustained quality control procedures in a clinical laboratory.
Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N
2013-01-01
Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.
Motor abilities and anthropometrics in youth cross-country skiing.
Stöggl, R; Müller, E; Stöggl, T
2015-02-01
The purposes were to validate whether general motor abilities and anthropometrics are determinants of youth cross-country (XC) skiing performance; evaluate gender-specific differences; and to establish noninvasive diagnostics. Fifty-one youth XC skiers (34 boys; 13.8 ± 0.6 years and 17 girls; 13.4 ± 0.9 years) performed motor skill and laboratory tests, and anthropometric data were collected and correlated with XC skiing performance. Anthropometrics and maturity status were related to boys but not to girls XC skiing performance. Push-ups and 20-m sprint were correlated to XC skiing performance in both boys and girls. XC skiing performance of boys was predominantly influenced by upper body and trunk strength capacities (medicine ball throw, push-ups, and pull-ups) and jumping power (standing long and triple jump), whereas XC skiing of girls was mainly influenced by aerobic capacities (3000-m run). Laboratory measures did not reveal greater correlations to XC skiing performance compared with simple test concepts of speed, strength, and endurance. Maturity was a major confounding variable in boys but not girls. Use of noninvasive simple test concepts for determination of upper body strength, speed, and endurance represent practicable support for ski clubs, schools, or skiing federations in the guidance and evaluation of young talent, being aware of the effect of maturity especially in boys. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Cicenaite, Aurelija; Huckins, James N.; Alvarez, David A.; Cranor, Walter L.; Gale, Robert W.; Kauneliene, Violeta; Bergqvist, Per-Anders
2007-01-01
Semipermeable membrane devices (SPMDs) are a widely used passive sampling methodology for both waterborne and airborne hydrophobic organic contaminants. The exchange kinetics and partition coefficients of an analyte in a SPMD are mediated by its physicochemical properties and certain environmental conditions. Controlled laboratory experiments are used for determining the SPMD–air (Ksa's) partition coefficients and the exchange kinetics of organic vapors. This study focused on determining a simple approach for measuring equilibrium Ksa's for naphthalene (Naph), o-chlorophenol (o-CPh) and p-dichlorobenzene (p-DCB) over a wide range of temperatures. SPMDs were exposed to test chemical vapors in small, gas-tight chambers at four different temperatures (−16, −4, 22 and 40 °C). The exposure times ranged from 6 h to 28 d depending on test temperature. Ksa's or non-equilibrium concentrations in SPMDs were determined for all compounds, temperatures and exposure periods with the exception of Naph, which could not be quantified in SPMDs until 4 weeks at the −16 °C temperature. To perform this study the assumption of constant and saturated atmospheric concentrations in test chambers was made. It could influence the results, which suggest that flow through experimental system and performance reference compounds should be used for SPMD calibration.
Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T
2016-02-01
The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.
Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw; Robert Vatalaro
2005-01-01
This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...
HYPERCALCURIA AND METABOLIC BONE DISEASE
Rosenberg, Milton L.
1954-01-01
Hypercalcuria leading to nephrocalcinosis and nephrolithiasis may be secondary to a number of causes. In most instances, the history, physical examination, a few simple laboratory tests and x-ray study of the bones will reveal the true primary diagnosis. Specific treatment, if instituted early, will result in a satisfactory response and prevent the progression of renal complications. ImagesFigure 1.Figure 2.Figure 3.Figure 4. PMID:13209371
De Bartolo, Samuele; Fallico, Carmine; Veltri, Massimo
2013-01-01
Hydraulic conductivity and effective porosity values for the confined sandy loam aquifer of the Montalto Uffugo (Italy) test field were obtained by laboratory and field measurements; the first ones were carried out on undisturbed soil samples and the others by slug and aquifer tests. A direct simple-scaling analysis was performed for the whole range of measurement and a comparison among the different types of fractal models describing the scale behavior was made. Some indications about the largest pore size to utilize in the fractal models were given. The results obtained for a sandy loam soil show that it is possible to obtain global indications on the behavior of the hydraulic conductivity versus the porosity utilizing a simple scaling relation and a fractal model in coupled manner. PMID:24385876
An accelerating precursor to predict "time-to-failure" in creep and volcanic eruptions
NASA Astrophysics Data System (ADS)
Hao, Shengwang; Yang, Hang; Elsworth, Derek
2017-09-01
Real-time prediction by monitoring of the evolution of response variables is a central goal in predicting rock failure. A linear relation Ω˙Ω¨-1 = C(tf - t) has been developed to describe the time to failure, where Ω represents a response quantity, C is a constant and tf represents the failure time. Observations from laboratory creep failure experiments and precursors to volcanic eruptions are used to test the validity of the approach. Both cumulative and simple moving window techniques are developed to perform predictions and to illustrate the effects of data selection on the results. Laboratory creep failure experiments on granites show that the linear relation works well during the final approach to failure. For blind prediction, the simple moving window technique is preferred because it always uses the most recent data and excludes effects of early data deviating significantly from the predicted trend. When the predicted results show only small fluctuations, failure is imminent.
Howson, E L A; Armson, B; Lyons, N A; Chepkwony, E; Kasanga, C J; Kandusi, S; Ndusilo, N; Yamazaki, W; Gizaw, D; Cleaveland, S; Lembo, T; Rauh, R; Nelson, W M; Wood, B A; Mioulet, V; King, D P; Fowler, V L
2018-02-01
Effective control and monitoring of foot-and-mouth disease (FMD) relies upon rapid and accurate disease confirmation. Currently, clinical samples are usually tested in reference laboratories using standardized assays recommended by The World Organisation for Animal Health (OIE). However, the requirements for prompt and serotype-specific diagnosis during FMD outbreaks, and the need to establish robust laboratory testing capacity in FMD-endemic countries have motivated the development of simple diagnostic platforms to support local decision-making. Using a portable thermocycler, the T-COR™ 8, this study describes the laboratory and field evaluation of a commercially available, lyophilized pan-serotype-specific real-time RT-PCR (rRT-PCR) assay and a newly available FMD virus (FMDV) typing assay (East Africa-specific for serotypes: O, A, Southern African Territories [SAT] 1 and 2). Analytical sensitivity, diagnostic sensitivity and specificity of the pan-serotype-specific lyophilized assay were comparable to that of an OIE-recommended laboratory-based rRT-PCR (determined using a panel of 57 FMDV-positive samples and six non-FMDV vesicular disease samples for differential diagnosis). The FMDV-typing assay was able to correctly identify the serotype of 33/36 FMDV-positive samples (no cross-reactivity between serotypes was evident). Furthermore, the assays were able to accurately detect and type FMDV RNA in multiple sample types, including epithelial tissue suspensions, serum, oesophageal-pharyngeal (OP) fluid and oral swabs, both with and without the use of nucleic acid extraction. When deployed in laboratory and field settings in Tanzania, Kenya and Ethiopia, both assays reliably detected and serotyped FMDV RNA in samples (n = 144) collected from pre-clinical, clinical and clinically recovered cattle. These data support the use of field-ready rRT-PCR platforms in endemic settings for simple, highly sensitive and rapid detection and/or characterization of FMDV. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
NASA Technical Reports Server (NTRS)
1985-01-01
The primary objective of the Test Active Control Technology (ACT) System laboratory tests was to verify and validate the system concept, hardware, and software. The initial lab tests were open loop hardware tests of the Test ACT System as designed and built. During the course of the testing, minor problems were uncovered and corrected. Major software tests were run. The initial software testing was also open loop. These tests examined pitch control laws, wing load alleviation, signal selection/fault detection (SSFD), and output management. The Test ACT System was modified to interface with the direct drive valve (DDV) modules. The initial testing identified problem areas with DDV nonlinearities, valve friction induced limit cycling, DDV control loop instability, and channel command mismatch. The other DDV issue investigated was the ability to detect and isolate failures. Some simple schemes for failure detection were tested but were not completely satisfactory. The Test ACT System architecture continues to appear promising for ACT/FBW applications in systems that must be immune to worst case generic digital faults, and be able to tolerate two sequential nongeneric faults with no reduction in performance. The challenge in such an implementation would be to keep the analog element sufficiently simple to achieve the necessary reliability.
Investigation of thermolytic hydrogen generation rate of tank farm simulated and actual waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martino, C.; Newell, D.; Woodham, W.
To support resolution of Potential Inadequacies in the Safety Analysis for the Savannah River Site (SRS) Tank Farm, Savannah River National Laboratory conducted research to determine the thermolytic hydrogen generation rate (HGR) with simulated and actual waste. Gas chromatography methods were developed and used with air-purged flow systems to quantify hydrogen generation from heated simulated and actual waste at rates applicable to the Tank Farm Documented Safety Analysis (DSA). Initial simulant tests with a simple salt solution plus sodium glycolate demonstrated the behavior of the test apparatus by replicating known HGR kinetics. Additional simulant tests with the simple salt solutionmore » excluding organics apart from contaminants provided measurement of the detection and quantification limits for the apparatus with respect to hydrogen generation. Testing included a measurement of HGR on actual SRS tank waste from Tank 38. A final series of measurements examined HGR for a simulant with the most common SRS Tank Farm organics at temperatures up to 140 °C. The following conclusions result from this testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmann, D.L.; Luke, K.W.; Terry, J.C.
1984-07-01
The results of a study to determine the relative grindability of US limestones and to relate grindability to petrographic properties are presented in this report. A laboratory ball mill test was developed to provide a quick and simple measure of grindability. These values were then used to explore possible correlations between grindability and the chemical and physical properties of the limestones. Chemical analyses and thin section petrographic analyses were used to characterize the limestone samples. The results of the laboratory ball mill test were compared to the results of an industrial grinding test, the Bond Work Index, for six samplesmore » which covered the grindability range. The two tests compared well with a correlation coefficient greater than 0.9. While the laboratory test is not sufficient to provide ball mill design specifications, it can be used as a screening and quality control test. The grinding results, expressed as a grindability index, ranged in values from 2 to 15. This represents a seven-fold range in the relative difficulties to grind for the limestones tested. From the petrographic analysis results, a strong correlation was found between the grindability and the fraction of macrocrystalline (> 5 ..mu..m) carbonate minerals present in the limestone. However, based on the high degree of variability characteristic of most limestone deposits, petrographic information should, in general, only be used to qualitatively predict the grindability of a specific limestone. An actual grinding test is recommended for a quantitative evaluation.« less
NASA Astrophysics Data System (ADS)
Diemoz, P. C.; Endrizzi, M.; Vittoria, F. A.; Hagen, C. K.; Kallon, G.; Basta, D.; Marenzana, M.; Delogu, P.; Vincenzi, A.; De Ruvo, L.; Spandre, G.; Brez, A.; Bellazzini, R.; Olivo, A.
2015-03-01
Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has potential for applications in different fields of research, including materials science, non-destructive industrial testing, small-animal imaging, and medical imaging. One of its main advantages is the compatibility with laboratory equipment, in particular with conventional non-microfocal sources, which makes its exploitation in normal research laboratories possible. In this work, we demonstrate that the signal in laboratory implementations of EI can be correctly described with the use of the simplified geometrical optics. Besides enabling the derivation of simple expressions for the sensitivity and spatial resolution of a given EI setup, this model also highlights the EI's achromaticity. With the aim of improving image quality, as well as to take advantage of the fact that all energies in the spectrum contribute to the image contrast, we carried out EI acquisitions using a photon-counting energy-resolved detector. The obtained results demonstrate that this approach has great potential for future laboratory implementations of EI.
Magnezi, Racheli; Hemi, Asaf; Hemi, Rina
2016-01-01
Background Risk management in health care systems applies to all hospital employees and directors as they deal with human life and emergency routines. There is a constant need to decrease risk and increase patient safety in the hospital environment. The purpose of this article is to review the laboratory testing procedures for parathyroid hormone and adrenocorticotropic hormone (which are characterized by short half-lives) and to track failure modes and risks, and offer solutions to prevent them. During a routine quality improvement review at the Endocrine Laboratory in Tel Hashomer Hospital, we discovered these tests are frequently repeated unnecessarily due to multiple failures. The repetition of the tests inconveniences patients and leads to extra work for the laboratory and logistics personnel as well as the nurses and doctors who have to perform many tasks with limited resources. Methods A team of eight staff members accompanied by the Head of the Endocrine Laboratory formed the team for analysis. The failure mode and effects analysis model (FMEA) was used to analyze the laboratory testing procedure and was designed to simplify the process steps and indicate and rank possible failures. Results A total of 23 failure modes were found within the process, 19 of which were ranked by level of severity. The FMEA model prioritizes failures by their risk priority number (RPN). For example, the most serious failure was the delay after the samples were collected from the department (RPN =226.1). Conclusion This model helped us to visualize the process in a simple way. After analyzing the information, solutions were proposed to prevent failures, and a method to completely avoid the top four problems was also developed. PMID:27980440
Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities
Parsons, Linda M.; Somoskövi, Ákos; Gutierrez, Cristina; Lee, Evan; Paramasivan, C. N.; Abimiku, Alash'le; Spector, Steven; Roscigno, Giorgio; Nkengasong, John
2011-01-01
Summary: With an estimated 9.4 million new cases globally, tuberculosis (TB) continues to be a major public health concern. Eighty percent of all cases worldwide occur in 22 high-burden, mainly resource-poor settings. This devastating impact of tuberculosis on vulnerable populations is also driven by its deadly synergy with HIV. Therefore, building capacity and enhancing universal access to rapid and accurate laboratory diagnostics are necessary to control TB and HIV-TB coinfections in resource-limited countries. The present review describes several new and established methods as well as the issues and challenges associated with implementing quality tuberculosis laboratory services in such countries. Recently, the WHO has endorsed some of these novel methods, and they have been made available at discounted prices for procurement by the public health sector of high-burden countries. In addition, international and national laboratory partners and donors are currently evaluating other new diagnostics that will allow further and more rapid testing in point-of-care settings. While some techniques are simple, others have complex requirements, and therefore, it is important to carefully determine how to link these new tests and incorporate them within a country's national diagnostic algorithm. Finally, the successful implementation of these methods is dependent on key partnerships in the international laboratory community and ensuring that adequate quality assurance programs are inherent in each country's laboratory network. PMID:21482728
A Simple Low-Cost Lock-In Amplifier for the Laboratory
ERIC Educational Resources Information Center
Sengupta, Sandip K.; Farnham, Jessica M.; Whitten, James E.
2005-01-01
The creation of a simple, low-cost lock-in amplifier (LIA) suitable for use in the chemistry teaching laboratory is described. The use of integrated circuits and few components are necessary to adequately accomplish lock-in amplification limited the total cost of construction to under US$100.
Simple & Rapid Generation of Complex DNA Profiles for the Undergraduate Laboratory
ERIC Educational Resources Information Center
Kass, David H.
2007-01-01
Deoxyribonucleic acid (DNA) profiles can be generated by a variety of techniques incorporating different types of DNA markers. Simple methods are commonly utilized in the undergraduate laboratory, but with certain drawbacks. In this article, the author presents an advancement of the "Alu" dimorphism technique involving two tetraplex polymerase…
High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory
ERIC Educational Resources Information Center
Frey, Douglas D.; Guo, Hui; Karnik, Nikhila
2013-01-01
This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…
Raybould, J N; Mhiddin, H K
1974-01-01
The maintenance of Simulium adults in the laboratory is necessary for many experimental investigations and is a prerequisite to laboratory colonization. A simple technique for this purpose is described in which each fly is kept separately in a hole bored in a block of expanded polystyrene.
Inactivation of stable viruses in cell culture facilities by peracetic acid fogging.
Gregersen, Jens-Peter; Roth, Bernhard
2012-07-01
Looking for a robust and simple method to replace formaldehyde fumigation for the disinfection of virus-handling laboratories and facilities, we tested peracetic acid fogging as a method to inactivate stable viruses under practical conditions. Peracetic acid/hydrogen peroxide (5.8%/27.5%, 2.0 mL/m³) was diluted in sufficient water to achieve ≥ 70% relative humidity and was vaporized as <10 μm droplets in a fully equipped 95 m³ laboratory unit. High titers of reovirus 3, MVM parvovirus and an avian polyomavirus were coated on frosted glass carriers and were exposed to the peracetic acid fog in various positions in the laboratory. After vaporization, a 60 min exposure time, and venting of the laboratory, no residual virus was detected on any of the carriers (detection limit <1 infectious unit/sample volume tested). The log reduction values were 9.0 for reovirus, 6.4 for MVM parvovirus, and 7.65 for the polyomavirus. After more than 10 disinfection runs within 12 months, no damage or functional impairment of electrical and electronic equipment was noted. Copyright © 2012 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
ShareSync: A Solution for Deterministic Data Sharing over Ethernet
NASA Technical Reports Server (NTRS)
Dunn, Daniel J., II; Koons, William A.; Kennedy, Richard D.; Davis, Philip A.
2007-01-01
As part of upgrading the Contact Dynamics Simulation Laboratory (CDSL) at the NASA Marshall Space Flight Center (MSFC), a simple, cost effective method was needed to communicate data among the networked simulation machines and I/O controllers used to run the facility. To fill this need and similar applicable situations, a generic protocol was developed, called ShareSync. ShareSync is a lightweight, real-time, publish-subscribe Ethernet protocol for simple and deterministic data sharing across diverse machines and operating systems. ShareSync provides a simple Application Programming Interface (API) for simulation programmers to incorporate into their code. The protocol is compatible with virtually all Ethernet-capable machines, is flexible enough to support a variety of applications, is fast enough to provide soft real-time determinism, and is a low-cost resource for distributed simulation development, deployment, and maintenance. The first design cycle iteration of ShareSync has been completed, and the protocol has undergone several testing procedures including endurance and benchmarking tests and approaches the 2001ts data synchronization design goal for the CDSL.
A Systematic Experimental Test of the Ideal Gas Equation for the General Chemistry Laboratory
NASA Astrophysics Data System (ADS)
Blanco, Luis H.; Romero, Carmen M.
1995-10-01
A set of experiments that examines each one of the terms of the ideal gas equation is described. Boyle's Law, Charles-Gay Lussac's Law, Amonton's Law, the number of moles or Molecular Weight, and the Gas Constant are studied. The experiments use very simple, easy to obtain equipment and common gases, mainly air. The results gathered by General Chemistry College students are satisfactory.
Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi
2013-01-01
The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.
NASA Technical Reports Server (NTRS)
Hirschberg, M. H.
1978-01-01
Twenty laboratories in six countries participated in this program, each testing its own materials of interest under its own laboratory conditions. In this way the results obtained provided validation of the Strainrange Partitioning (SRP) method for a wide range of materials and insured maximum usefulness to each of the participating laboratories. The first, very necessary step in the evaluation of any life prediction approach - assessing the ability of the method to predict life of simple laboratory specimens subjected to complex loading, was thereby taken. The culmination of this program was the Specialists Meeting that was held in Aalborg, Denmark in April of 1978. At that meeting the various investigators shared their findings, thus providing the basis for an in-depth evaluation of the SRP method. While the results were variable from laboratory to laboratory, most investigators agreed that the SRP method was a significant step toward life prediction in the presence of high temperature and cyclic stresses.
Insights from analysis for harmful and potentially harmful constituents (HPHCs) in tobacco products.
Oldham, Michael J; DeSoi, Darren J; Rimmer, Lonnie T; Wagner, Karl A; Morton, Michael J
2014-10-01
A total of 20 commercial cigarette and 16 commercial smokeless tobacco products were assayed for 96 compounds listed as harmful and potentially harmful constituents (HPHCs) by the US Food and Drug Administration. For each product, a single lot was used for all testing. Both International Organization for Standardization and Health Canada smoking regimens were used for cigarette testing. For those HPHCs detected, measured levels were consistent with levels reported in the literature, however substantial assay variability (measured as average relative standard deviation) was found for most results. Using an abbreviated list of HPHCs, statistically significant differences for most of these HPHCs occurred when results were obtained 4-6months apart (i.e., temporal variability). The assay variability and temporal variability demonstrate the need for standardized analytical methods with defined repeatability and reproducibility for each HPHC using certified reference standards. Temporal variability also means that simple conventional comparisons, such as two-sample t-tests, are inappropriate for comparing products tested at different points in time from the same laboratory or from different laboratories. Until capable laboratories use standardized assays with established repeatability, reproducibility, and certified reference standards, the resulting HPHC data will be unreliable for product comparisons or other decision making in regulatory science. Copyright © 2014 Elsevier Inc. All rights reserved.
Williamson, A M; Feyer, A M; Mattick, R P; Friswell, R; Finlay-Brown, S
2001-05-01
The effects of 28 h of sleep deprivation were compared with varying doses of alcohol up to 0.1% blood alcohol concentration (BAC) in the same subjects. The study was conducted in the laboratory. Twenty long-haul truck drivers and 19 people not employed as professional drivers acted as subjects. Tests were selected that were likely to be affected by fatigue, including simple reaction time, unstable tracking, dual task, Mackworth clock vigilance test, symbol digit coding, visual search, sequential spatial memory and logical reasoning. While performance effects were seen due to alcohol for all tests, sleep deprivation affected performance on most tests, but had no effect on performance on the visual search and logical reasoning tests. Some tests showed evidence of a circadian rhythm effect on performance, in particular, simple reaction time, dual task, Mackworth clock vigilance, and symbol digit coding, but only for response speed and not response accuracy. Drivers were slower but more accurate than controls on the symbol digit test, suggesting that they took a more conservative approach to performance of this test. This study demonstrated which tests are most sensitive to sleep deprivation and fatigue. The study therefore has established a set of tests that can be used in evaluations of fatigue and fatigue countermeasures.
Evaluation of filter media for particle number, surface area and mass penetrations.
Li, Lin; Zuo, Zhili; Japuntich, Daniel A; Pui, David Y H
2012-07-01
The National Institute for Occupational Safety and Health (NIOSH) developed a standard for respirator certification under 42 CFR Part 84, using a TSI 8130 automated filter tester with photometers. A recent study showed that photometric detection methods may not be sensitive for measuring engineered nanoparticles. Present NIOSH standards for penetration measurement are mass-based; however, the threshold limit value/permissible exposure limit for an engineered nanoparticle worker exposure is not yet clear. There is lack of standardized filter test development for engineered nanoparticles, and development of a simple nanoparticle filter test is indicated. To better understand the filter performance against engineered nanoparticles and correlations among different tests, initial penetration levels of one fiberglass and two electret filter media were measured using a series of polydisperse and monodisperse aerosol test methods at two different laboratories (University of Minnesota Particle Technology Laboratory and 3M Company). Monodisperse aerosol penetrations were measured by a TSI 8160 using NaCl particles from 20 to 300 nm. Particle penetration curves and overall penetrations were measured by scanning mobility particle sizer (SMPS), condensation particle counter (CPC), nanoparticle surface area monitor (NSAM), and TSI 8130 at two face velocities and three layer thicknesses. Results showed that reproducible, comparable filtration data were achieved between two laboratories, with proper control of test conditions and calibration procedures. For particle penetration curves, the experimental results of monodisperse testing agreed well with polydisperse SMPS measurements. The most penetrating particle sizes (MPPSs) of electret and fiberglass filter media were ~50 and 160 nm, respectively. For overall penetrations, the CPC and NSAM results of polydisperse aerosols were close to the penetration at the corresponding median particle sizes. For each filter type, power-law correlations between the penetrations measured by different instruments show that the NIOSH TSI 8130 test may be used to predict penetrations at the MPPS as well as the CPC and NSAM results with polydisperse aerosols. It is recommended to use dry air (<20% RH) as makeup air in the test system to prevent sodium chloride particle deliquescing and minimizing the challenge particle dielectric constant and to use an adequate neutralizer to fully neutralize the polydisperse challenge aerosol. For a simple nanoparticle penetration test, it is recommended to use a polydisperse aerosol challenge with a geometric mean of ~50 nm with the CPC or the NSAM as detectors.
Optimized theory for simple and molecular fluids.
Marucho, M; Montgomery Pettitt, B
2007-03-28
An optimized closure approximation for both simple and molecular fluids is presented. A smooth interpolation between Perkus-Yevick and hypernetted chain closures is optimized by minimizing the free energy self-consistently with respect to the interpolation parameter(s). The molecular version is derived from a refinement of the method for simple fluids. In doing so, a method is proposed which appropriately couples an optimized closure with the variant of the diagrammatically proper integral equation recently introduced by this laboratory [K. M. Dyer et al., J. Chem. Phys. 123, 204512 (2005)]. The simplicity of the expressions involved in this proposed theory has allowed the authors to obtain an analytic expression for the approximate excess chemical potential. This is shown to be an efficient tool to estimate, from first principles, the numerical value of the interpolation parameters defining the aforementioned closure. As a preliminary test, representative models for simple fluids and homonuclear diatomic Lennard-Jones fluids were analyzed, obtaining site-site correlation functions in excellent agreement with simulation data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snelson, C. M., Chipman, V. D., White, R. L., Emmitt, R. F., Townsend, M. J., Barker, D., Lee, P.
Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. Themore » Source Physics Experiment at the Nevada National Security Site (SPE-N) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green’s function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1-N was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2-N was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3-N was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability.« less
NASA Astrophysics Data System (ADS)
Zaazaa, H. E.; Elzanfaly, E. S.; Soudi, A. T.; Salem, M. Y.
2016-03-01
A new smart simple validated spectrophotometric method was developed for the determination of two drugs one of which is in a very low concentration compared to the other. The method is based on spiking and dilution then simple mathematical manipulation of the absorbance spectra. This method was applied for the determination of a binary mixture of vildagliptin and metformin hydrochloride in the ratio 50:850 in laboratory prepared mixtures containing both drugs in this ratio and in pharmaceutical dosage form with good recoveries. The developed method was validated according to ICH guidelines and can be used for routine quality control testing.
NASA Astrophysics Data System (ADS)
Ivković, Saša S.; Marković, Marija Z.; Ivković, Dragica Ž.; Cvetanović, Nikola
2017-09-01
Equivalent series resistance (ESR) represents the measurement of total energy loss in a capacitor. In this paper a simple method for measuring the ESR of ceramic capacitors based on the analysis of the oscillations of an LCR circuit is proposed. It is shown that at frequencies under 3300 Hz, the ESR is directly proportional to the period of oscillations. Based on the determined dependence of the ESR on the period, a method is devised and tested for measuring coil inductance. All measurements were performed using the standard equipment found in student laboratories, which makes both methods very suitable for implementation at high school and university levels.
Göbel, Gero; Lange, Robert; Hollidt, Jörg-Michael; Lisdat, Fred
2016-01-01
The fast and simple detection of increased protein concentrations in cerebrospinal liquids is preferable in the emergency medicine and it can help to avoid unnecessary laboratory work by an early classification of neurological diseases. Here a test system is developed which is based on the electrostatic interaction between negatively charged gold nanoparticles and proteins at pH values around 5. The test system can be adjusted in such a way that protein/nanoparticles aggregates are formed leading to a red-shift in the absorption spectrum of the nanoparticles suspension. At concentrations above 500 mg/l the color of the suspension changes from red via violet toward blue in a rather small concentration range from 500 to 1000 mg/l. Furthermore the influence of various parameters such as gold nanoparticle concentration, pH value and varying ion concentration in the sample on the test system is examined. Finally cerebrospinal liquids of a larger number of patients have been analyzed. Copyright © 2015 Elsevier B.V. All rights reserved.
DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.
2004-03-24
Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNAmore » populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.« less
Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.
Westgard, James O; Westgard, Sten A
2017-03-01
Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.
Bioturbation, advection, and diffusion of a conserved tracer in a laboratory flume
NASA Astrophysics Data System (ADS)
Work, P. A.; Moore, P. R.; Reible, D. D.
2002-06-01
Laboratory experiments indicating the relative influences of advection, diffusion, and bioturbation on transport of NaCl tracer between a stream and streambed are described. Data were collected in a recirculating flume housing a box filled with test sediments. Peclet numbers ranged from 0 to 1.5. Sediment components included a medium sand (d50 = 0.31 mm), kaolinite, and topsoil. Lumbriculus variegatus were introduced as bioturbators. Conductivity probes were employed to document the flux of the tracer solution out of the bed. Measurements are compared to one-dimensional effective diffusion models assuming one or two horizontal sediment layers. These simple models provide a good indication of tracer half-life in the bed if a suitable effective diffusion coefficient is chosen but underpredict initial flux and overpredict flux at long times. Organism activity was limited to the upper reaches of the sediment test box but eventually exerts a secondary influence on flux from deeper regions.
NASA Astrophysics Data System (ADS)
Yahya, I.; Kusuma, J. I.; Harjana; Kristiani, R.; Hanina, R.
2016-02-01
This paper emphasizes the influence of tubular shaped microresonators phononic crystal insertion on the sound absorption coefficient of profiled sound absorber. A simple cubic and two different bodies centered cubic phononic crystal lattice model were analyzed in a laboratory test procedure. The experiment was conducted by using transfer function based two microphone impedance tube method refer to ASTM E-1050-98. The results show that sound absorption coefficient increase significantly at the mid and high-frequency band (600 - 700 Hz) and (1 - 1.6 kHz) when tubular shaped microresonator phononic crystal inserted into the tested sound absorber element. The increment phenomena related to multi-resonance effect that occurs when sound waves propagate through the phononic crystal lattice model that produce multiple reflections and scattering in mid and high-frequency band which increases the sound absorption coefficient accordingly
Sonic-boom-induced building structure responses including damage.
NASA Technical Reports Server (NTRS)
Clarkson, B. L.; Mayes, W. H.
1972-01-01
Concepts of sonic-boom pressure loading of building structures and the associated responses are reviewed, and results of pertinent theoretical and experimental research programs are summarized. The significance of sonic-boom load time histories, including waveshape effects, are illustrated with the aid of simple structural elements such as beams and plates. Also included are discussions of the significance of such other phenomena as three-dimensional loading effects, air cavity coupling, multimodal responses, and structural nonlinearities. Measured deflection, acceleration, and strain data from laboratory models and full-scale building tests are summarized, and these data are compared, where possible, with predicted values. Damage complaint and claim experience due both to controlled and uncontrolled supersonic flights over communities are summarized with particular reference to residential, commercial, and historic buildings. Sonic-boom-induced building responses are compared with those from other impulsive loadings due to natural and cultural events and from laboratory simulation tests.
A Scalable and Dynamic Testbed for Conducting Penetration-Test Training in a Laboratory Environment
2015-03-01
entry point through which to execute a payload to accomplish a higher-level goal: executing arbitrary code, escalating privileges , pivoting...Mobile Ad Hoc Network Emulator (EMANE)26 can emulate the entire network stack (physical to application -layer protocols). 2. Methodology To build a...to host Windows, Linux, MacOS, Android , and other operating systems without much effort. 4 E. A simple and automatic “restore” function: Many
Using Operational Analysis to Improve Access to Pulmonary Function Testing.
Ip, Ada; Asamoah-Barnieh, Raymond; Bischak, Diane P; Davidson, Warren J; Flemons, W Ward; Pendharkar, Sachin R
2016-01-01
Background. Timely pulmonary function testing is crucial to improving diagnosis and treatment of pulmonary diseases. Perceptions of poor access at an academic pulmonary function laboratory prompted analysis of system demand and capacity to identify factors contributing to poor access. Methods. Surveys and interviews identified stakeholder perspectives on operational processes and access challenges. Retrospective data on testing demand and resource capacity was analyzed to understand utilization of testing resources. Results. Qualitative analysis demonstrated that stakeholder groups had discrepant views on access and capacity in the laboratory. Mean daily resource utilization was 0.64 (SD 0.15), with monthly average utilization consistently less than 0.75. Reserved testing slots for subspecialty clinics were poorly utilized, leaving many testing slots unfilled. When subspecialty demand exceeded number of reserved slots, there was sufficient capacity in the pulmonary function schedule to accommodate added demand. Findings were shared with stakeholders and influenced scheduling process improvements. Conclusion. This study highlights the importance of operational data to identify causes of poor access, guide system decision-making, and determine effects of improvement initiatives in a variety of healthcare settings. Importantly, simple operational analysis can help to improve efficiency of health systems with little or no added financial investment.
Mansoor, Sana; Collyer, Elizabeth; Alkhouri, Naim
2015-06-01
Nonalcoholic fatty liver disease (NAFLD) and its spectrum ranging from simple steatosis to nonalcoholic steatohepatitis (NASH) and fibrosis have been increasing in the pediatric population. The presence and severity of fibrosis in patients with NAFLD are important prognostic factors for the risk of disease progression to cirrhosis. The gold standard for staging liver fibrosis is a liver biopsy. However, given the risks of this procedure, especially in the pediatric population, the development of noninvasive markers to diagnose and monitor progression of NAFLD is desirable. This paper will review recently developed noninvasive methods for diagnosing liver fibrosis in children with NAFLD. These include simple fibrosis scores, advanced biochemical markers, and radiologic imaging studies. Simple fibrosis scores use readily available laboratory tests; available one include AST/ALT ratio, AST to platelet ratio index (APRI), fibrosis (FIB)-4 index, NAFLD fibrosis score (NFS), pediatric NAFLD fibrosis index (PNFI), and pediatric NALFD fibrosis score (PNFS). Advanced biochemical markers include biomarkers of hepatocyte cell death such as cytokeratin 18 fragment levels, and markers of extracellular matrix turnover such as the Enhanced Liver Fibrosis (ELF) test and hyaluronic acid. Radiologic imaging studies estimate liver stiffness as a surrogate for liver fibrosis; these include transient elastography (TE), magnetic resonance elastography (MRE), and acoustic radiation force impulse imaging (ARFI).
Simple genetic transformation assay for rapid diagnosis of Moraxella osloensis.
Juni, E
1974-01-01
A genetic transformation assay for unequivocal identification of strains of Moraxella osloensis is described. In this assay a stable tryptophan auxotroph is transformed to prototrophy by deoxyribonucleic acid (DNA) samples from other strains of M. osloensis but not by DNA samples from unrelated bacteria. The test is simple to perform and definitive results can be obtained in less than 24 h. The procedure, which is suitable for routine diagnosis in a clinical laboratory, involves a rapid method for preparation of crude transforming DNA from small quantities of bacterial cells and permits simultaneous examination of large numbers of isolated cultures. The assay was shown to correctly identify 27 strains previously classified as M. osloensis. Forty-five other gram-negative, oxidase-positive, nonmotile coccobacilli, which might be confused with M. osloensis unless subject to more extensive testing, were shown to be unrelated genetically to M. osloensis. The transformation assay clearly distinguishes M. osloensis from Acinetobacter. Although most strains of M. osloensis are nonfastidious, being able to grow in a mineral medium supplemented with a single organic carbon source, one of the strains tested was only able to grow on fairly complex media and could not be transformed to grow on simple media. Inability to alkalize Simmons citrate agar was shown not to be characteristic of all strains of M. osloensis.
Simple Genetic Transformation Assay for Rapid Diagnosis of Moraxella osloensis
Juni, Elliot
1974-01-01
A genetic transformation assay for unequivocal identification of strains of Moraxella osloensis is described. In this assay a stable tryptophan auxotroph is transformed to prototrophy by deoxyribonucleic acid (DNA) samples from other strains of M. osloensis but not by DNA samples from unrelated bacteria. The test is simple to perform and definitive results can be obtained in less than 24 h. The procedure, which is suitable for routine diagnosis in a clinical laboratory, involves a rapid method for preparation of crude transforming DNA from small quantities of bacterial cells and permits simultaneous examination of large numbers of isolated cultures. The assay was shown to correctly identify 27 strains previously classified as M. osloensis. Forty-five other gram-negative, oxidase-positive, nonmotile coccobacilli, which might be confused with M. osloensis unless subject to more extensive testing, were shown to be unrelated genetically to M. osloensis. The transformation assay clearly distinguishes M. osloensis from Acinetobacter. Although most strains of M. osloensis are nonfastidious, being able to grow in a mineral medium supplemented with a single organic carbon source, one of the strains tested was only able to grow on fairly complex media and could not be transformed to grow on simple media. Inability to alkalize Simmons citrate agar was shown not to be characteristic of all strains of M. osloensis. Images PMID:4589126
OMEGA: A NEW COLD X-RAY SIMULATION FACILITY FOR THE EVALUATION OF OPTICAL COATINGS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, J H; Newlander, C D; Fournier, K B
We report on recent progress for the development of a new cold X-ray optical test capability using the Omega Facility located at the Laboratory for Laser Energetics (LLE) at the University of Rochester. These tests were done on the 30 kJ OMEGA laser at the Laboratory for Laser Energetics (LLE) at the University of Rochester, Rochester, NY. We conducted a six-shot series called OMEGA II on 14 July 2006 in one eight-hour day (supported by the Defense Threat Reduction Agency). The initial testing was performed using simple protected gold optical coatings on fused silica substrates. PUFFTFT analyses were completed andmore » the specimen's thermal lateral stress and transverse stress conditions were calculated and interpreted. No major anomalies were detected. Comparison of the pre- and posttest reflective measurements coupled with the TFCALC analyses proved invaluable in guiding the analyses and interpreting the observed damage. The Omega facility is a high quality facility for performing evaluation of optical coatings and coupons and provides experience for the development of future National Ignition Facility (NIF) testing.« less
Chandu, Dilip; Paul, Sudakshina; Parker, Mathew; Dudin, Yelena; King-Sitzes, Jennifer; Perez, Tim; Mittanck, Don W; Shah, Manali; Glenn, Kevin C; Piepenburg, Olaf
2016-01-01
Testing for the presence of genetically modified material in seed samples is of critical importance for all stakeholders in the agricultural industry, including growers, seed manufacturers, and regulatory bodies. While rapid antibody-based testing for the transgenic protein has fulfilled this need in the past, the introduction of new variants of a given transgene demands new diagnostic regimen that allows distinguishing different traits at the nucleic acid level. Although such molecular tests can be performed by PCR in the laboratory, their requirement for expensive equipment and sophisticated operation have prevented its uptake in point-of-use applications. A recently developed isothermal DNA amplification technique, recombinase polymerase amplification (RPA), combines simple sample preparation and amplification work-flow procedures with the use of minimal detection equipment in real time. Here, we report the development of a highly sensitive and specific RPA-based detection system for Genuity Roundup Ready 2 Yield (RR2Y) material in soybean (Glycine max) seed samples and present the results of studies applying the method in both laboratory and field-type settings.
ERIC Educational Resources Information Center
Klara, Kristina; Hou, Ning; Lawman, Allison; Wu, Liheng; Morrill, Drew; Tente, Alfred; Wang, Li-Qiong
2014-01-01
A simple, affordable hydrogen proton exchange membrane (PEM) fuel cell laboratory was developed through a collaborative effort between faculty and undergraduate students at Brown University. It has been incorporated into the introductory chemistry curriculum and successfully implemented in a class of over 500 students per academic year for over 3…
Raybould, John N.; Mhiddin, Haji K.
1974-01-01
The maintenance of Simulium adults in the laboratory is necessary for many experimental investigations and is a prerequisite to laboratory colonization. A simple technique for this purpose is described in which each fly is kept separately in a hole bored in a block of expanded polystyrene. ImagesFig. 1 PMID:4549353
An investigation of the direct-drive method of susceptibility testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonn, R.H.
1992-07-01
The Naval Surface Weapons Laboratory has constructed a small electrical subsystem for the purpose of evaluating electrical upset from various electromagnetic sources. The subsystem consists of three boxes, two of which are intended to be illuminated by electromagnetic waves. The two illuminated boxes are connected by two unshielded cable bundles. The goal of the Navy test series is to expose the subsystem to electromagnetic illumination from several different types of excitation, document upset levels, and compare the results. Before its arrival at Sandia National Laboratories (SNL) the system was illuminated in a mode stirred chamber and in an anechoic chamber.more » This effort was a continuation of that test program. The Sandia tests involved the test methodology referred to as bulk current injection (BCI). Because this is a poorly-shielded, multiple-aperture system, the method was not expected to compare closely to the other test methods. The test results show that. The BCI test methodology is a useful test technique for a subset of limited aperture systems; the methodology will produce incorrect answers when used improperly on complex systems; the methodology can produce accurate answers on simple systems with a well-controlled electromagnetic topology. This is a preliminary study and the results should be interpreted carefully.« less
Neil, Amanda; Pfeffer, Sally; Burnett, Leslie
2013-01-01
This paper details the development of a new type of pathology laboratory productivity unit, the benchmarking complexity unit (BCU). The BCU provides a comparative index of laboratory efficiency, regardless of test mix. It also enables estimation of a measure of how much complex pathology a laboratory performs, and the identification of peer organisations for the purposes of comparison and benchmarking. The BCU is based on the theory that wage rates reflect productivity at the margin. A weighting factor for the ratio of medical to technical staff time was dynamically calculated based on actual participant site data. Given this weighting, a complexity value for each test, at each site, was calculated. The median complexity value (number of BCUs) for that test across all participating sites was taken as its complexity value for the Benchmarking in Pathology Program. The BCU allowed implementation of an unbiased comparison unit and test listing that was found to be a robust indicator of the relative complexity for each test. Employing the BCU data, a number of Key Performance Indicators (KPIs) were developed, including three that address comparative organisational complexity, analytical depth and performance efficiency, respectively. Peer groups were also established using the BCU combined with simple organisational and environmental metrics. The BCU has enabled productivity statistics to be compared between organisations. The BCU corrects for differences in test mix and workload complexity of different organisations and also allows for objective stratification into peer groups.
An easy, rapid and inexpensive method to monitor tributyltin (TBT) toxicity in the laboratory.
Cruz, Andreia; Moreira, Rafael; Mendo, Sónia
2014-05-01
Tributyltin (TBT) contamination remains a major problem worldwide. Many laboratories are committed to the development of remediation methodologies that could help reduce the negative impact of this compound in the environment. Furthermore, it is important to have at hand simple methodologies for evaluating TBT toxicity in the laboratory, besides the use of complex and costly analytical instrumentation. With that purpose, a method was adapted that is based on the inhibition of growth of an indicator strain, Micrococcus luteus ATCC 9341, under TBT. Different types of matrices, of TBT concentrations and sample treatments were tested. The results herein reported show that the bioassay method can be applied for both aqueous and soil samples and also for a high range of TBT concentrations (at least up to 500 μmol/L). Besides being cheap and easy to perform, it can be performed in any laboratory. Additionally, one possible application of the method to monitor TBT degradation is presented as an example.
Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.
Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel
2011-11-01
Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.
Prevalence of latent tuberculosis infection among tuberculosis laboratory workers in Iran.
Nasehi, Mahshid; Hashemi-Shahraki, Abdolrazagh; Doosti-Irani, Amin; Sharafi, Saeed; Mostafavi, Ehsan
2017-01-01
The risk of transmission of Mycobacterium tuberculosis from patients to health care workers (HCWs) is a neglected problem in many countries, including Iran. The aim of this study was to estimate the prevalence of latent tuberculosis (TB) infection (LTBI) among TB laboratory staff in Iran, and to elucidate the risk factors associated with LTBI. All TB laboratory staff (689 individuals) employed in the TB laboratories of 50 Iranian universities of medical sciences and a random sample consisting of 317 low-risk HCWs were included in this cross-sectional study. Participants with tuberculin skin test indurations of 10 mm or more were considered to have an LTBI. The prevalence of LTBI among TB laboratory staff and low-risk HCWs was 24.83% (95% confidence interval [CI], 21.31 to 27.74%) and 14.82% (95% CI, 11.31 to 19.20%), respectively. No active TB cases were found in either group. After adjusting for potential confounders, TB laboratory staff were more likely to have an LTBI than low-risk HCWs (prevalence odds ratio, 2.06; 95% CI, 1.35 to 3.17). This study showed that LTBI are an occupational health problem among TB laboratory staff in Iran. This study reinforces the need to design and implement simple, effective, and affordable TB infection control programs in TB laboratories in Iran.
ERIC Educational Resources Information Center
Unlu, Zeynep Koyunlu; Dokme, Ibilge
2011-01-01
The purpose of this study was to investigate whether the combination of both analogy-based simulation and laboratory activities as a teaching tool was more effective than utilizing them separately in teaching the concepts of simple electricity. The quasi-experimental design that involved 66 seventh grade students from urban Turkish elementary…
ERIC Educational Resources Information Center
Cloonan, Carrie A.; Andrew, Julie A.; Nichol, Carolyn A.; Hutchinson, John S.
2011-01-01
This article describes an activity that can be used as an inquiry-based laboratory or demonstration for either high school or undergraduate chemistry students to provide a basis for understanding both vapor pressure and the concept of dynamic phase equilibrium. The activity includes a simple setup to create a closed system of only water liquid and…
ERIC Educational Resources Information Center
Maloney, Vincent; Szczepanski, Zach
2017-01-01
A simple, inexpensive, discovery-based experiment for undergraduate organic laboratories has been developed that demonstrates the Lewis acid and shape-selective properties of zeolites. Calcined zeolite Na-Y promotes the electrophilic aromatic bromination of toluene with a significantly higher para/ortho ratio than observed under conventional…
SHERLOCK: Simple Human Experiments Regarding Locally Observed Collective Knowledge
2015-12-01
ARL-RP-0560 ● DEC 2015 US Army Research Laboratory SHERLOCK: Simple Human Experiments Regarding Locally Observed Collective...report when it is no longer needed. Do not return it to the originator. ARL-RP-0560 ● DEC 2015 US Army Research Laboratory SHERLOCK... Research and Engineering Directorate, ARL Reprinted from the International Technology Alliance Collaboration System [accessed 2015 Dec 2]. https
Tartari, Flamur; Buzo, Stiliano; Vyshka, Gentian
2009-01-01
The apparatus invented by Dr. Luigj Benusi in 1943, in Tirana, was a practical application of the Kowarsky technique and Ambard laws, helping in determining blood urea levels and very important to a variety of diseases, mainly kidney disorders. The apparatus was invented and prepared from very simple laboratory materials, such as glasses, test tubes, corks and volumetric cylinders. Technologically, it was based upon the determination of blood urea through hypobromite, and, among the advantages of the apparatus of Benusi, were its extreme simplicity, the smaller amount of blood needed for producing results (2 milliliters), as well as an easiest way to clean up and to manage the apparatus from a practical point of everyday use.
Design and Testing of Flight Control Laws on the RASCAL Research Helicopter
NASA Technical Reports Server (NTRS)
Frost, Chad R.; Hindson, William S.; Moralez. Ernesto, III; Tucker, George E.; Dryfoos, James B.
2001-01-01
Two unique sets of flight control laws were designed, tested and flown on the Army/NASA Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) JUH-60A Black Hawk helicopter. The first set of control laws used a simple rate feedback scheme, intended to facilitate the first flight and subsequent flight qualification of the RASCAL research flight control system. The second set of control laws comprised a more sophisticated model-following architecture. Both sets of flight control laws were developed and tested extensively using desktop-to-flight modeling, analysis, and simulation tools. Flight test data matched the model predicted responses well, providing both evidence and confidence that future flight control development for RASCAL will be efficient and accurate.
NASA Astrophysics Data System (ADS)
Emiliannur, E.; Hamidah, I.; Zainul, A.; Wulan, A. R.
2017-09-01
Performance Assessment Model (PAM) has been developed to represent the physics concepts which able to be devided into five experiments: 1) acceleration due to gravity; 2) Hooke’s law; 3) simple harmonic motion; 4) work-energy concepts; and 5) the law of momentum conservation. The aim of this study was to determine the contribution of PAM in physics laboratory to increase students’ Critical Thinking Disposition (CTD) at senior high school. Subject of the study were 11th grade consist 32 students of a senior high school in Lubuk Sikaping, West Sumatera. The research used one group pretest-postest design. Data was collected through essay test and questionnaire about CTD. Data was analyzed using quantitative way with N-gain value. This study concluded that performance assessmet model effectively increases the N-gain at medium category. It means students’ critical thinking disposition significant increase after implementation of performance assessment model in physics laboratory.
Indirect Charged Particle Detection: Concepts and a Classroom Demonstration
NASA Astrophysics Data System (ADS)
Childs, Nicholas B.; Horányi, Mihály; Collette, Andrew
2013-11-01
We describe the principles of macroscopic charged particle detection in the laboratory and their connections to concepts taught in the physics classroom. Electrostatic dust accelerator systems, capable of launching charged dust grains at hypervelocities (1-100 km/s), are a critical tool for space exploration. Dust grains in space typically have large speeds relative to the probes or satellites that encounter them. Development and testing of instruments that look for dust in space therefore depends critically on the availability of fast, well-characterized dust grains in the laboratory. One challenge for the experimentalist is to precisely measure the speed and mass of laboratory dust particles without disturbing them. Detection systems currently in use exploit the well-known effect of image charge to register the passage of dust grains without changing their speed or mass. We describe the principles of image charge detection and provide a simple classroom demonstration of the technique using soup cans and pith balls.
A simple, low-cost, data logging pendulum built from a computer mouse
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gintautas, Vadas; Hubler, Alfred
Lessons and homework problems involving a pendulum are often a big part of introductory physics classes and laboratory courses from high school to undergraduate levels. Although laboratory equipment for pendulum experiments is commercially available, it is often expensive and may not be affordable for teachers on fixed budgets, particularly in developing countries. We present a low-cost, easy-to-build rotary sensor pendulum using the existing hardware in a ball-type computer mouse. We demonstrate how this apparatus may be used to measure both the frequency and coefficient of damping of a simple physical pendulum. This easily constructed laboratory equipment makes it possible formore » all students to have hands-on experience with one of the most important simple physical systems.« less
2007-01-01
Objective To evaluate the feasibility and diagnostic accuracy of screening for coeliac disease by rapid detection of IgA antibodies to tissue transglutaminase performed in primary care. Design District nurses screened 6 year old children using rapid antibody testing of finger prick blood. They also collected capillary blood samples for laboratory determination of IgA and IgG antibodies to endomysium and IgA antibodies to tissue transglutaminase. Children with positive rapid test results were directly sent for biopsy of the small intestine. Setting Primary care in Jász-Nagykun-Szolnok county, Hungary. Participants 2690 children (77% of 6 year olds living in the county) and 120 nurses. Main outcome measures Positivity for antibodies to endomysium or transglutaminase in the laboratory and coeliac disease confirmed at biopsy. Results 37 children (1.4%, 95% confidence interval 0.9% to 1.8%) had biopsy confirmed coeliac disease. Only five of these children had been diagnosed clinically before screening. Rapid testing had a 78.1% sensitivity (70.0% to 89.3%) and 100% specificity (88.4% to 100%) for a final diagnosis of coeliac disease by biopsy. Sensitivity was 65.1% (50.2% to 77.6%) and specificity was 100% (99.8% to 100%) compared with combined results of IgA and IgG laboratory tests. Trained laboratory workers detected 30 of the 31 newly diagnosed IgA competent patients with the rapid test kit used blindly. Median time to biopsy after a positive rapid test result was significantly shorter (20 days, range 4-148) than after a positive laboratory result (142 days, 70-256; P<0.001). Children with coeliac disease detected at screening were smaller and had worse health status than their peers but they improved on a gluten-free diet. Conclusions A simple rapid antibody test enabled primary care nurses to detect patients with coeliac disease in the community who were not picked up in clinical care. Extra training is needed to improve sensitivity. PMID:18063612
GMOseek: a user friendly tool for optimized GMO testing.
Morisset, Dany; Novak, Petra Kralj; Zupanič, Darko; Gruden, Kristina; Lavrač, Nada; Žel, Jana
2014-08-01
With the increasing pace of new Genetically Modified Organisms (GMOs) authorized or in pipeline for commercialization worldwide, the task of the laboratories in charge to test the compliance of food, feed or seed samples with their relevant regulations became difficult and costly. Many of them have already adopted the so called "matrix approach" to rationalize the resources and efforts used to increase their efficiency within a limited budget. Most of the time, the "matrix approach" is implemented using limited information and some proprietary (if any) computational tool to efficiently use the available data. The developed GMOseek software is designed to support decision making in all the phases of routine GMO laboratory testing, including the interpretation of wet-lab results. The tool makes use of a tabulated matrix of GM events and their genetic elements, of the laboratory analysis history and the available information about the sample at hand. The tool uses an optimization approach to suggest the most suited screening assays for the given sample. The practical GMOseek user interface allows the user to customize the search for a cost-efficient combination of screening assays to be employed on a given sample. It further guides the user to select appropriate analyses to determine the presence of individual GM events in the analyzed sample, and it helps taking a final decision regarding the GMO composition in the sample. GMOseek can also be used to evaluate new, previously unused GMO screening targets and to estimate the profitability of developing new GMO screening methods. The presented freely available software tool offers the GMO testing laboratories the possibility to select combinations of assays (e.g. quantitative real-time PCR tests) needed for their task, by allowing the expert to express his/her preferences in terms of multiplexing and cost. The utility of GMOseek is exemplified by analyzing selected food, feed and seed samples from a national reference laboratory for GMO testing and by comparing its performance to existing tools which use the matrix approach. GMOseek proves superior when tested on real samples in terms of GMO coverage and cost efficiency of its screening strategies, including its capacity of simple interpretation of the testing results.
Petersen, J.H.; DeAngelis, D.L.; Paukert, C.P.
2008-01-01
Many fish species are at risk to some degree, and conservation efforts are planned or underway to preserve sensitive populations. For many imperiled species, models could serve as useful tools for researchers and managers as they seek to understand individual growth, quantify predator-prey dynamics, and identify critical sources of mortality. Development and application of models for rare species however, has been constrained by small population sizes, difficulty in obtaining sampling permits, limited opportunities for funding, and regulations on how endangered species can be used in laboratory studies. Bioenergetic and life history models should help with endangered species-recovery planning since these types of models have been used successfully in the last 25 years to address management problems for many commercially and recreationally important fish species. In this paper we discuss five approaches to developing models and parameters for rare species. Borrowing model functions and parameters from related species is simple, but uncorroborated results can be misleading. Directly estimating parameters with laboratory studies may be possible for rare species that have locally abundant populations. Monte Carlo filtering can be used to estimate several parameters by means of performing simple laboratory growth experiments to first determine test criteria. Pattern-oriented modeling (POM) is a new and developing field of research that uses field-observed patterns to build, test, and parameterize models. Models developed using the POM approach are closely linked to field data, produce testable hypotheses, and require a close working relationship between modelers and empiricists. Artificial evolution in individual-based models can be used to gain insight into adaptive behaviors for poorly understood species and thus can fill in knowledge gaps. ?? Copyright by the American Fisheries Society 2008.
Rapid, whole blood diagnostic test for detecting anti-hantavirus antibody in rats.
Amada, Takako; Yoshimatsu, Kumiko; Yasuda, Shumpei P; Shimizu, Kenta; Koma, Takaaki; Hayashimoto, Nobuhito; Gamage, Chandika D; Nishio, Sanae; Takakura, Akira; Arikawa, Jiro
2013-10-01
Hantavirus is a causative agent of rodent-borne viral zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome. Seoul virus (SEOV) is a causative agent of urban and laboratory rat-associated HFRS worldwide. Surveillance of rodents has been done mainly by serological detection of hantavirus-specific antibodies by enzyme linked immunosorbent assay (ELISA) and immunofluorescent antibody assay (IFA). An immunochromatographic (ICG) test was developed with the N-terminal 103 amino acids of nucleocapsid protein of Hantaan virus expressed by Escherichia coli as an antigen to detect IgG antibody specific to hantavirus in sera from Rattus sp. animals. Antibody-detecting sensitivity of the ICG test was the same as that of ELISA and about 100-times higher than that of IFA. Overall sensitivities and specificities of the ICG test in comparison to ELISA and IFA for sera from 192 urban rats and 123 laboratory rats were 99.3% and 100%, respectively. Diluted whole blood samples without separation could be used for the ICG test. The ICG test enabled detection of antibodies to SEOV, Hantaan, Dobrava/Belgrade, and Thailand viruses, which are causative agents of HFRS throughout Eurasia. The ICG test is a rapid, simple and safe method for diagnosis of SEOV infection in rats. Copyright © 2013 Elsevier B.V. All rights reserved.
The Source Physics Experiments (SPE) at the Nevada National Security Site (NNSS): An Overview
NASA Astrophysics Data System (ADS)
Snelson, C. M.; Chipman, V.; White, R. L.; Emmitt, R.; Townsend, M.; Barker, D.; Lee, P.
2012-12-01
Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. The Source Physics Experiment at the Nevada National Security Site (SPE) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green's function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1 was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2 was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3 was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability. This work was done by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946--1584
Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S
2016-01-01
Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.
Sumithra, T G; Chaturvedi, V K; Gupta, P K; Sunita, S C; Rai, A K; Kutty, M V H; Laxmi, U; Murugan, M S
2014-05-01
A specific latex agglutination test (LAT) based on anti-PA (protective antigen) antibodies having detection limit of 5 × 10(4) formalin treated Bacillus anthracis cells or 110 ng of PA was optimized in this study. The optimized LAT could detect anthrax toxin in whole blood as well as in serum from the animal models of anthrax infection. The protocol is a simple and promising method for the specific detection of bacteria causing anthrax under routine laboratory, as well as in field, conditions without any special equipments or expertise. The article presents the first report of a latex agglutination test for the specific identification of the cultures of bacteria causing anthrax. As the test is targeting one of anthrax toxic protein (PA), this can also be used to determine virulence of suspected organisms. At the same time, the same LAT can be used directly on whole blood or sera samples under field conditions for the specific diagnosis of anthrax. © 2013 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Iradat, R. D.; Alatas, F.
2017-09-01
Simple harmonic motion is considered as a relatively complex concept to be understood by students. This study attempts to implement laboratory activities that focus on solving contextual problems related to the concept. A group of senior high school students participated in this pre-experimental method from a group’s pretest-posttest research design. Laboratory activities have had a positive impact on improving students’ scientific skills, such as, formulating goals, conducting experiments, applying laboratory tools, and collecting data. Therefore this study has added to the theoretical and practical knowledge that needs to be considered to teach better complicated concepts in physics learning.
ERIC Educational Resources Information Center
Sobrero, Patricio; Valverde, Claudio
2013-01-01
A simple and cheap laboratory class is proposed to illustrate the lethal effect of UV radiation on bacteria and the operation of different DNA repair mechanisms. The class is divided into two sessions, an initial 3-hour experimental session and a second 2-hour analytical session. The experimental session involves two separate experiments: one…
ERIC Educational Resources Information Center
Lisovskiy, V. A.; Koval, V. A.; Artushenko, E. P.; Yegorenkov, V. D.
2012-01-01
In this paper we suggest a simple technique for validating the Goldstein-Wehner law for a stratified positive column of dc glow discharge while studying the properties of gas discharges in an undergraduate laboratory. To accomplish this a simple device with a pre-vacuum mechanical pump, dc source and gas pressure gauge is required. Experiments may…
Membrane electrode gasket assembly (MEGA) technology for polymer electrolyte fuel cells
NASA Astrophysics Data System (ADS)
Pozio, A.; Giorgi, L.; De Francesco, M.; Silva, R. F.; Lo Presti, R.; Danzi, A.
A new technology for the production of a membrane electrode gasket assembly (MEGA) for polymer electrolyte fuel cells (PEFCs) is defined. The MEGA system was prepared by sealing a previously prepared membrane electrode assembly (MEA) in a moulded gasket. For this aim, a proprietary silicone based liquid mixture was injected directly into the MEA borders. Gaskets obtained in different shapes and hardness grades are stable in a wide temperature range. The MEGA technology shows several advantages with respect to traditional PEFCs stack assembling systems: effective membrane saving, reduced fabrication time, possibility of quality control and failed elements substitution. This technology was successfully tested at the ENEA laboratories and the results were acquired in laboratory scale, but industrial production appears to be simple and cheap.
Study of Dominant Factors Affecting Cerchar Abrasivity Index
NASA Astrophysics Data System (ADS)
Rostami, Jamal; Ghasemi, Amireza; Alavi Gharahbagh, Ehsan; Dogruoz, Cihan; Dahl, Filip
2014-09-01
The Cerchar abrasion index is commonly used to represent rock abrasion for estimation of bit life and wear in various mining and tunneling applications. Although the test is simple and fast, there are some discrepancies in the test results related to the equipment used, condition of the rock surface, operator skills, and procedures used in conducting and measuring the wear surface. This paper focuses on the background of the test and examines the influence of various parameters on Cerchar testing including pin hardness, surface condition of specimens, petrographical and geomechanical properties, test speed, applied load, and method of measuring wear surface. Results of Cerchar tests on a set of rock specimens performed at different laboratories are presented to examine repeatability of the tests. In addition, the preliminary results of testing with a new device as a potential alternative testing system for rock abrasivity measurement are discussed.
2013-01-01
Background All rigorous primary cardiovascular disease (CVD) prevention guidelines recommend absolute CVD risk scores to identify high- and low-risk patients, but laboratory testing can be impractical in low- and middle-income countries. The purpose of this study was to compare the ranking performance of a simple, non-laboratory-based risk score to laboratory-based scores in various South African populations. Methods We calculated and compared 10-year CVD (or coronary heart disease (CHD)) risk for 14,772 adults from thirteen cross-sectional South African populations (data collected from 1987 to 2009). Risk characterization performance for the non-laboratory-based score was assessed by comparing rankings of risk with six laboratory-based scores (three versions of Framingham risk, SCORE for high- and low-risk countries, and CUORE) using Spearman rank correlation and percent of population equivalently characterized as ‘high’ or ‘low’ risk. Total 10-year non-laboratory-based risk of CVD death was also calculated for a representative cross-section from the 1998 South African Demographic Health Survey (DHS, n = 9,379) to estimate the national burden of CVD mortality risk. Results Spearman correlation coefficients for the non-laboratory-based score with the laboratory-based scores ranged from 0.88 to 0.986. Using conventional thresholds for CVD risk (10% to 20% 10-year CVD risk), 90% to 92% of men and 94% to 97% of women were equivalently characterized as ‘high’ or ‘low’ risk using the non-laboratory-based and Framingham (2008) CVD risk score. These results were robust across the six risk scores evaluated and the thirteen cross-sectional datasets, with few exceptions (lower agreement between the non-laboratory-based and Framingham (1991) CHD risk scores). Approximately 18% of adults in the DHS population were characterized as ‘high CVD risk’ (10-year CVD death risk >20%) using the non-laboratory-based score. Conclusions We found a high level of correlation between a simple, non-laboratory-based CVD risk score and commonly-used laboratory-based risk scores. The burden of CVD mortality risk was high for men and women in South Africa. The policy and clinical implications are that fast, low-cost screening tools can lead to similar risk assessment results compared to time- and resource-intensive approaches. Until setting-specific cohort studies can derive and validate country-specific risk scores, non-laboratory-based CVD risk assessment could be an effective and efficient primary CVD screening approach in South Africa. PMID:23880010
Analysis of pre-service physics teacher skills designing simple physics experiments based technology
NASA Astrophysics Data System (ADS)
Susilawati; Huda, C.; Kurniawan, W.; Masturi; Khoiri, N.
2018-03-01
Pre-service physics teacher skill in designing simple experiment set is very important in adding understanding of student concept and practicing scientific skill in laboratory. This study describes the skills of physics students in designing simple experiments based technologicall. The experimental design stages include simple tool design and sensor modification. The research method used is descriptive method with the number of research samples 25 students and 5 variations of simple physics experimental design. Based on the results of interviews and observations obtained the results of pre-service physics teacher skill analysis in designing simple experimental physics charged technology is good. Based on observation result, pre-service physics teacher skill in designing simple experiment is good while modification and sensor application are still not good. This suggests that pre-service physics teacher still need a lot of practice and do experiments in designing physics experiments using sensor modifications. Based on the interview result, it is found that students have high enough motivation to perform laboratory activities actively and students have high curiosity to be skilled at making simple practicum tool for physics experiment.
ERIC Educational Resources Information Center
Erdmann, Mitzy A.; March, Joe L.
2016-01-01
Sample handling and laboratory notebook maintenance are necessary skills but can seem abstract if not presented to students in context. An introductory exercise focusing on proper sample handling, data collection and laboratory notebook keeping for the general chemistry laboratory was developed to emphasize the importance of keeping an accurate…
Solidification and Acceleration of Large Cryogenic Pellets Relevant for Plasma Disruption Mitigation
Combs, Stephen Kirk; Meitner, S. J.; Gebhart, T. E.; ...
2016-01-01
The technology for producing, accelerating, and shattering large pellets (before injection into plasmas) for disruption mitigation has been under development at the Oak Ridge National Laboratory for several years, including a system on DIII-D that has been used to provide some significant experimental results. The original proof-of-principle testing was carried out using a pipe gun injector cooled by a cryogenic refrig- erator (temperatures ~8-20 K) and equipped with a stainless steel tube to produce 16.5-mm pellets composed of either pure D 2, pure Ne, or a dual layer with a thin outer shell of D 2 and core of Ne.more » Recently, significant progress has been made in the laboratory using that same pipe gun and a new injector that is an ITER test apparatus cooled with liquid helium. The new injector operates at ~5-8 K, which is similar to temperatures expected with cooling provided by the flow of supercritical helium on ITER. An alternative technique for producing/solidifying large pellets directly from a premixed gas has now been successfully tested in the laboratory. Also, two additional pellet sizes have been tested recently (nominal 24.4 and 34.0 mm diameters). With larger pellets, the number of injectors required for ITER disruption mitigation can be reduced, resulting in less cost and a smaller footprint for the hardware. An attractive option is longer pellets, and 24.4-mm pellets with a length/diameter ratio of ~3 have been successfully tested. Since pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event, recent tests have concentrated on documenting the speeds with different hardware configurations and operating parameters; speeds of ~100-800 m/s have been recorded. The data and results from laboratory testing are presented and discussed, and a simple model for the pellet solidification process is described.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain S.; Wray, Craig P.; Guillot, Cyril
2003-08-01
In this report, we discuss the accuracy of flow hoods for residential applications, based on laboratory tests and field studies. The results indicate that commercially available hoods are often inadequate to measure flows in residential systems, and that there can be a wide range of performance between different flow hoods. The errors are due to poor calibrations, sensitivity of existing hoods to grille flow non-uniformities, and flow changes from added flow resistance. We also evaluated several simple techniques for measuring register airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics that are often as accuratemore » as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, organizations such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow hoods.« less
First French Pilot Quality Assessment of the EndoPredict Test for Early Luminal Breast Carcinoma.
Lehmann-Che, Jacqueline; Miquel, Catherine; Wong, Jennifer; Callens, Celine; Rouleau, Etienne; Quillien, Veronique; Lozano, Nicolas; Cayre, Anne; Lacroix, Ludovic; Bieche, Ivan; Bertheau, Philippe; Teixeira, Luis; Llorca, Frederique Penault; Lamy, Pierre Jean; DE Cremoux, Patricia
2018-05-01
Genomic signatures are needed for the determination of prognosis in patients with early stage, estrogen receptor (ER)-positive, human epidermal growth factor receptor 2 (HER2)-negative breast cancers. EndoPredict test is a RNA-based multigene assay that assesses the risk of 10-year relapse in this context. Quality assessment is a mandatory requirement for a laboratory to address the analytical quality of these molecular analyses. The aim of the study was to demonstrate the robustness of this prognostic test, its usefulness for the patient's treatment strategy, at the national level. This study presents a pilot quality assessment (QA) of the EndoPredict test using composite design, including the follow-up of internal control values (qREF) of the 12 genes of the assay for 151 independent tests and one formalin-fixed paraffin embedded (FFPE) breast cancer sample. The evaluation of the test was performed by comparing the results of six independent medical laboratories. All measures were highly reproducible and quantification of the qREF showed a standard deviation of less than 0.50 and a coefficient of variation always of <2%. All laboratories found concordant results for the breast cancer samples. The mean EndoPredict (EP) score for the breast cancer sample was 4.97±0.24. The mean of EPclin score was 3.07±0.05. This first French independent reported QA assessed the robustness and reproducibility of the EndoPredict test. Such a simple composite design could represent an adapted QA for an expensive diagnostic test. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Faris, Allison T.; Seed, Raymond B.; Kayen, Robert E.; Wu, Jiaer
2006-01-01
During the 1906 San Francisco Earthquake, liquefaction-induced lateral spreading and resultant ground displacements damaged bridges, buried utilities, and lifelines, conventional structures, and other developed works. This paper presents an improved engineering tool for the prediction of maximum displacement due to liquefaction-induced lateral spreading. A semi-empirical approach is employed, combining mechanistic understanding and data from laboratory testing with data and lessons from full-scale earthquake field case histories. The principle of strain potential index, based primary on correlation of cyclic simple shear laboratory testing results with in-situ Standard Penetration Test (SPT) results, is used as an index to characterized the deformation potential of soils after they liquefy. A Bayesian probabilistic approach is adopted for development of the final predictive model, in order to take fullest advantage of the data available and to deal with the inherent uncertainties intrinstiic to the back-analyses of field case histories. A case history from the 1906 San Francisco Earthquake is utilized to demonstrate the ability of the resultant semi-empirical model to estimate maximum horizontal displacement due to liquefaction-induced lateral spreading.
Toward laboratory blood test-comparable photometric assessments for anemia in veterinary hematology
NASA Astrophysics Data System (ADS)
Kim, Taehoon; Choi, Seung Ho; Lambert-Cheatham, Nathan; Xu, Zhengbin; Kritchevsky, Janice E.; Bertin, Francois-René; Kim, Young L.
2016-10-01
Anemia associated with intestinal parasites and malnutrition is the leading cause of morbidity and mortality in small ruminants worldwide. Qualitative scoring of conjunctival redness has been developed so that farmers can gauge anemia in sheep and goats to identify animals that require treatment. For clinically relevant anemia diagnosis, complete blood count-comparable quantitative methods often rely on complicated and expensive optical instruments, requiring detailed spectral information of hemoglobin. We report experimental and numerical results for simple, yet reliable, noninvasive hemoglobin detection that can be correlated with laboratory-based blood hemoglobin testing for anemia diagnosis. In our pilot animal study using calves, we exploit the third eyelid (i.e., palpebral conjunctiva) as an effective sensing site. To further test spectrometer-free (or spectrometerless) hemoglobin assessments, we implement full spectral reconstruction from RGB data and partial least square regression. The unique combination of RGB-based spectral reconstruction and partial least square regression could potentially offer uncomplicated instrumentation and avoid the use of a spectrometer, which is vital for realizing a compact and inexpensive hematology device for quantitative anemia detection in the farm field.
Barlow, Ian M
2008-01-01
Adding or incorporating clinical interpretative comments on biochemistry results is widespread in UK laboratories; although this consumes considerable human resource, there is still little evidence to suggest that it is either effective or appreciated by our clinical colleagues. I therefore decided to survey our local general practitioners (GPs) and nurse practitioners to analyse whether they found biochemistry comments on reports helpful. A simple questionnaire was designed and sent to 159 GPs and 81 nurse practitioners asking them whether they found this activity useful for the limited range of test groups that we routinely comment on and also whether they would like to see commenting on more groups of tests. Overall, 49.6% of questionnaires were returned. Of these, there was overwhelming support for commenting on reports and 77% would like to see comments on a greater range of tests. Although adding clinical interpretative comments is very time-consuming for senior laboratory staff, there is overwhelming support of this activity among our GPs and nurse practitioner users; therefore, our local policy of routinely adding clinical comments will remain for the foreseeable future.
Toward laboratory blood test-comparable photometric assessments for anemia in veterinary hematology.
Kim, Taehoon; Choi, Seung Ho; Lambert-Cheatham, Nathan; Xu, Zhengbin; Kritchevsky, Janice E; Bertin, Francois-René; Kim, Young L
2016-10-01
Anemia associated with intestinal parasites and malnutrition is the leading cause of morbidity and mortality in small ruminants worldwide. Qualitative scoring of conjunctival redness has been developed so that farmers can gauge anemia in sheep and goats to identify animals that require treatment. For clinically relevant anemia diagnosis, complete blood count-comparable quantitative methods often rely on complicated and expensive optical instruments, requiring detailed spectral information of hemoglobin. We report experimental and numerical results for simple, yet reliable, noninvasive hemoglobin detection that can be correlated with laboratory-based blood hemoglobin testing for anemia diagnosis. In our pilot animal study using calves, we exploit the third eyelid (i.e., palpebral conjunctiva) as an effective sensing site. To further test spectrometer-free (or spectrometerless) hemoglobin assessments, we implement full spectral reconstruction from RGB data and partial least square regression. The unique combination of RGB-based spectral reconstruction and partial least square regression could potentially offer uncomplicated instrumentation and avoid the use of a spectrometer, which is vital for realizing a compact and inexpensive hematology device for quantitative anemia detection in the farm field.
Wang, Ting; Zhang, Kun-He; Hu, Piao-Ping; Huang, Zeng-Yong; Zhang, Pan; Wan, Qin-Si; Huang, De-Qiang; Lv, Nong-Hua
2016-09-27
The diagnosis of early, small and alpha-fetoprotein (AFP)-negative primary hepatic carcinomas (PHCs) remains a significant challenge. We developed a simple and robust approach to noninvasively detect these PHCs. A rapid, high-throughput and single-tube method was firstly developed to measure serum autofluorescence and cell-free DNA (cfDNA)-related fluorescence using a real-time PCR system, and both types of serum fluorescence were measured and routine laboratory data were collected in 1229 subjects, including 353 PHC patients, 331 liver cirrhosis (LC) patients, 213 chronic hepatitis (CH) patients and 332 normal controls (NC). The results showed that fluorescence indicators of PHC differed from those of NC, CH and LC to various extents, and all of them were not associated with age, gender, or AFP level. The logistic regression models established with the fluorescence indicators alone and combined with AFP, hepatic function tests and blood cell analyses were valuable for distinguishing early, small, AFP-negative and all PHC from LC, CH, NC and all non-PHC, with areas under the receiver operating characteristic curves 0.857-0.993 and diagnostic accuracies 80.2-97.7%. Conclusively, serum autofluorescence and cfDNA-related fluorescence are able to be rapidly and simultaneously measured by our simple method and valuable for diagnosing early, small and AFP-negative PHCs, especially integrating with AFP and conventional blood tests.
Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L
2018-04-01
Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
Kalman Filters for UXO Detection: Real-Time Feedback and Small Target Detection
2012-05-01
last two decades. Accomplishments reported from both hardware and software point of views have moved the re- search focus from simple laboratory tests...quality data which in turn require a good positioning of the sensors atop the UXOs. The data collection protocol is currently based on a two-stage process...Note that this results is merely an illustration of the convergence of the Kalman filter. In practise , the linear part can be directly inverted for if
NASA Technical Reports Server (NTRS)
Johnson, Paul E.; Smith, Milton O.; Adams, John B.
1992-01-01
Algorithms were developed, based on Hapke's (1981) equations, for remote determinations of mineral abundances and particle sizes from reflectance spectra. In this method, spectra are modeled as a function of end-member abundances and illumination/viewing geometry. The method was tested on a laboratory data set. It is emphasized that, although there exist more sophisticated models, the present algorithms are particularly suited for remotely sensed data, where little opportunity exists to independently measure reflectance versus article size and phase function.
Petechiae and purpura: the ominous and the not-so-obvious?
Block, Stan L
2014-08-01
Petechiae and purpura are among the most alarming findings a pediatrician will commonly observe in the office. Severity of illness can range from a temper tantrum, to common viral infections, to the most deadly infections and diseases. To avoid many of the pitfalls in diagnosis, practitioners will need to be thorough in history taking, assessing fever and immunization status, and physical examination. In addition, a few simple laboratory tests will usually be needed and possibly a manual differential. Copyright 2014, SLACK Incorporated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filippetto, D.; /Frascati; Sannibale, F.
2008-01-24
By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and tested a simple scheme based on this principle that allows for the absolute measurement of the bunch length. A description of the method and the experimental results are presented.
1981-12-01
occurred on the Introversion Scale of the NMPI. 20 A review of the use of psychological tests on MT’s was accomplished by Driver and Feeley [1974...programs, Gondek [1981] has recommended that the best pro- cedure for variable inclusion when using a stepwise procedure is to use the threshold default...values supplied by the package, since no simple rules exist for determining entry or removal thresholds for partial F’s, tolerance statistics, or any of
Laboratory Tests for Legionnaire's Disease.
Dunne, W Michael; Picot, Nathalie; van Belkum, Alex
2017-03-01
Legionella pneumophila is one of the more recently discovered bacterial pathogens of humans. The last 2 decades have seen tremendous progress in the evolution of diagnostic tests, for detection and characterization of this pathogen and for defining the host response to infection. This has generated several diagnostic tools that span the range from simple immunologic assays to modern genome sequencing. This review describes the state of affairs of this continuously evolving field regarding the diagnosis of Legionnaire's disease and covers detection, assessment of antibiotic susceptibility, and epidemiologic characterization of isolates of L pneumophila and other pathogenic species within the genus. Copyright © 2016 Elsevier Inc. All rights reserved.
Rampling, A; Whitby, J L; Wildy, P
1975-11-01
A method for pyocin-sensitivity typing by means of "phage-free" preparations of pyocin is described. The method was tested on 227 isolates of P. aeruginosa, collected from 34 different foci of infection in hospitals in the British Isles and the results were compared with those for combined serological and phage typing of all strains and pyocin production of 105 of the isolates. It is concluded that pyocin-sensitivity typing is a simple and reliable method giving a high degree of discrimination, comparable to that of combined serological and phage typing, and it is suitable for use in routine hospital laboratories.
Robotics: a way to link the "islands of automation".
O'Bryan, D
1994-01-01
This article looks at what the natural evolution of robots can do for the clinical testing industry, from performing simple functions to becoming the prime labor force of the clinical laboratory. Until now, robots have been applied to instrument processes as somewhat of an upgrade to accomplish a variety of laboratory tasks. Over the next 10 years, however, robotics development will respond to the internal and external influences expected to challenge the industry. A limited supply of human workers and the increased demands of testing volumes and cost-effectiveness will herald a new phase of robotics to link, as well as develop, technological capabilities. Since science fiction was invented, robots have teased the imagination-alternately as mindless automatons or as clones of their inventors endowed with minds of their own. The appeal in the first case was the seemingly infinite capacity for performing menial tasks too boring, complex, or dangerous for mankind. The appeal in the second was the fantasy of artificial intelligence. In both cases, the fictional concept has become reality--and, by the 21st century, should even be commonplace. Financial encouragement of robotics development might even be a mission for laboratories themselves, as they prepare for potential competition from even more complex technology.
Sputum color: potential implications for clinical practice.
Johnson, Allen L; Hampson, David F; Hampson, Neil B
2008-04-01
Respiratory infections with sputum production are a major reason for physician visits, diagnostic testing, and antibiotic prescription in the United States. We sought to determine whether the simple characteristic of sputum color provides information that impacts resource utilization such as laboratory testing and prescription of antibiotics. Out-patient sputum samples submitted to the microbiology laboratory for routine analysis were assigned to one of 8 color categories (green, yellow-green, rust, yellow, red, cream, white, and clear), based on a key made from paint chip color samples. Subsequent Gram stain and culture results were compared to sputum color. Of 289 consecutive samples, 144 (50%) met standard Gram-stain criteria for being acceptable lower-respiratory-tract specimens. In the acceptable Gram-stain group, 60 samples had a predominant organism on Gram stain, and the culture yielded a consistent result in 42 samples (15% of the 289 total specimens). Yield at each level of analysis differed greatly by color. The yield from sputum colors green, yellow-green, yellow, and rust was much higher than the yield from cream, white, or clear. If out-patient sputum is cream, white, or clear, the yield from bacteriologic analysis is extremely low. This information can reduce laboratory processing costs and help minimize unnecessary antibiotic prescription.
Dose profile modeling of Idaho National Laboratory's active neutron interrogation laboratory.
Chichester, D L; Seabury, E H; Zabriskie, J M; Wharton, J; Caffrey, A J
2009-06-01
A new laboratory has been commissioned at Idaho National Laboratory for performing active neutron interrogation research and development. The facility is designed to provide radiation shielding for deuterium-tritium (DT) fusion (14.1 MeV) neutron generators (2 x 10(8) n/s), deuterium-deuterium (DD) fusion (2.5 MeV) neutron generators (1 x 10(7) n/s), and (252)Cf spontaneous fission neutron sources (6.96 x 10(7) n/s, 30 microg). Shielding at the laboratory is comprised of modular concrete shield blocks 0.76 m thick with tongue-in-groove features to prevent radiation streaming, arranged into one small and one large test vault. The larger vault is designed to allow operation of the DT generator and has walls 3.8m tall, an entrance maze, and a fully integrated electrical interlock system; the smaller test vault is designed for (252)Cf and DD neutron sources and has walls 1.9 m tall and a simple entrance maze. Both analytical calculations and numerical simulations were used in the design process for the building to assess the performance of the shielding walls and to ensure external dose rates are within required facility limits. Dose rate contour plots have been generated for the facility to visualize the effectiveness of the shield walls and entrance mazes and to illustrate the spatial profile of the radiation dose field above the facility and the effects of skyshine around the vaults.
Chandu, Dilip; Paul, Sudakshina; Parker, Mathew; Dudin, Yelena; King-Sitzes, Jennifer; Perez, Tim; Mittanck, Don W.; Shah, Manali; Glenn, Kevin C.; Piepenburg, Olaf
2016-01-01
Testing for the presence of genetically modified material in seed samples is of critical importance for all stakeholders in the agricultural industry, including growers, seed manufacturers, and regulatory bodies. While rapid antibody-based testing for the transgenic protein has fulfilled this need in the past, the introduction of new variants of a given transgene demands new diagnostic regimen that allows distinguishing different traits at the nucleic acid level. Although such molecular tests can be performed by PCR in the laboratory, their requirement for expensive equipment and sophisticated operation have prevented its uptake in point-of-use applications. A recently developed isothermal DNA amplification technique, recombinase polymerase amplification (RPA), combines simple sample preparation and amplification work-flow procedures with the use of minimal detection equipment in real time. Here, we report the development of a highly sensitive and specific RPA-based detection system for Genuity Roundup Ready 2 Yield (RR2Y) material in soybean (Glycine max) seed samples and present the results of studies applying the method in both laboratory and field-type settings. PMID:27314015
Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A
1999-01-01
The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.
Lead oxide as used in lead acid storage batteries, part two
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orsino, J.A.
1986-06-01
Without oxide controls, the battery manufacturing business can become one of the most confusing and frustrating experiences known. Inexplicable things happen during mixing, pasting and assembly, and testing, in the laboratory or in the field becomes an unhappy event. Almost any oxide of sufficient purity can be processed to make a good battery, but the characteristics must be known to be able to process it right, and once the process has been established, the oxide must be uniformly made to make the resulting batteries uniformly good. Fortunately, the tests required to assure uniformity are few, and simple to perform. Assumingmore » pure pig lead from primary sources or from carefully refined secondary sources, three tests can tell the whole story. These tests are described.« less
Proposal for a screening test to evaluate the fate of organic micropollutants in activated sludge.
Salvetti, Roberta; Vismara, Renato; Dal Ben, Ilaria; Gorla, Elena; Romele, Laura
2011-04-01
The concentrations of organic micropollutants are usually low in wastewaters (order of magnitude of mg L(-1)). However, their emission standards, especially in the case of carcinogenic and bioaccumulating substances, are often much lower (order of magnitude of microg L(-1)). Since these substances, in some cases, can be adsorbable or volatile, their removal via volatilization, biodegradation or sludge adsorption in a wastewater treatment plant (WWTP) becomes a significant feature to include in the usual design process, in order to verify the emission standards in gas and sludge too. In this study a simple screening batch test for the evaluation of the fate of organic micropollutants in water, air and sludge is presented. The test is set up by means of simple laboratory instruments and simulates an activated sludge tank process. In this study the results obtained for four substances with different chemical properties (i.e. toluene, benz(a)anthracene, phenol and benzene) are presented. The screening test proposed can be a useful tool to assess in about one month the fate of organic micropollutants in an activated sludge tank of a WWTP. Moreover, the test can constitute a useful support in the use of mathematical models, since it allows the verification of model results and the calibration of the reactions involved in the removal process.
Lightweight engine containment. [Kevlar shielding
NASA Technical Reports Server (NTRS)
Weaver, A. T.
1977-01-01
Kevlar fabric styles and weaves were studied, as well as methods of application for advanced gas turbine engines. The Kevlar material was subjected to high speed impacts by simple projectiles fired from a rifle, as well as more complex shapes such as fan blades released from gas turbine rotors in a spin pit. Just contained data was developed for a variety of weave and/or application techniques, and a comparative containment weight efficiency was established for Kevlar containment applications. The data generated during these tests is being incorporated into an analytical design system so that blade containment trade-off studies between Kevlar and metal case engine structures can be made. Laboratory tests and engine environment tests were performed to determine the survivability of Kevlar in a gas turbine environment.
Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum.
Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing
2014-05-01
Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of P. falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8-24 h followed by routine culture. When cultures with 27-60% of ring stage were synchronized using this procedure, 70-93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. Copyright © 2014 Elsevier Inc. All rights reserved.
Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum
Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M.; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing
2014-01-01
Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of Plasmodium falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8–24 h followed by routine culture. When cultures with 27–60% of ring stage were synchronized using this procedure, 70–93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. PMID:24632190
Real-time alpha monitoring of a radioactive liquid waste stream at Los Alamos National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, J.D.; Whitley, C.R.; Rawool-Sullivan, M.
1995-12-31
This poster display concerns the development, installation, and testing of a real-time radioactive liquid waste monitor at Los Alamos National Laboratory (LANL). The detector system was designed for the LANL Radioactive Liquid Waste Treatment Facility so that influent to the plant could be monitored in real time. By knowing the activity of the influent, plant operators can better monitor treatment, better segregate waste (potentially), and monitor the regulatory compliance of users of the LANL Radioactive Liquid Waste Collection System. The detector system uses long-range alpha detection technology, which is a nonintrusive method of characterization that determines alpha activity on themore » liquid surface by measuring the ionization of ambient air. Extensive testing has been performed to ensure long-term use with a minimal amount of maintenance. The final design was a simple cost-effective alpha monitor that could be modified for monitoring influent waste streams at various points in the LANL Radioactive Liquid Waste Collection System.« less
Holden, Brad; Guice, Erica A
2014-05-01
In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.
Zhang, Miao; Liu, Yinan; Chen, Lili; Quan, Sheng; Jiang, Shimeng; Zhang, Dabing; Yang, Litao
2013-01-02
Quickness, simplicity, and effectiveness are the three major criteria for establishing a good molecular diagnosis method in many fields. Herein we report a novel detection system for genetically modified organisms (GMOs), which can be utilized to perform both on-field quick screening and routine laboratory diagnosis. In this system, a newly designed inexpensive DNA extraction device was used in combination with a modified visual loop-mediated isothermal amplification (vLAMP) assay. The main parts of the DNA extraction device included a silica gel membrane filtration column and a modified syringe. The DNA extraction device could be easily operated without using other laboratory instruments, making it applicable to an on-field GMO test. High-quality genomic DNA (gDNA) suitable for polymerase chain reaction (PCR) and isothermal amplification could be quickly isolated from plant tissues using this device within 15 min. In the modified vLAMP assay, a microcrystalline wax encapsulated detection bead containing SYBR green fluorescent dye was introduced to avoid dye inhibition and cross-contaminations from post-LAMP operation. The system was successfully applied and validated in screening and identification of GM rice, soybean, and maize samples collected from both field testing and the Grain Inspection, Packers, and Stockyards Administration (GIPSA) proficiency test program, which demonstrated that it was well-adapted to both on-field testing and/or routine laboratory analysis of GMOs.
Median of patient results as a tool for assessment of analytical stability.
Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft; Sölétormos, György
2015-06-15
In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable analytical bias based on biological variation. Seventy five percent of the twenty analytes achieved on two COBASs INTEGRA 800 instruments performed in accordance with the optimum and with the desirable specifications for bias. Patient results applied in analytical quality performance control procedures are the most reliable sources of material as they represent the genuine substance of the measurements and therefore circumvent the problems associated with non-commutable materials in external assessment. Patient medians in the monthly monitoring of analytical stability in laboratory medicine are an inexpensive, simple and reliable tool to monitor the steadiness of the analytical practice. Copyright © 2015 Elsevier B.V. All rights reserved.
Nelson, Jonathan M.; Kinzel, Paul J.; Schmeeckle, Mark Walter; McDonald, Richard R.; Minear, Justin T.
2016-01-01
Noncontact methods for measuring water-surface elevation and velocity in laboratory flumes and rivers are presented with examples. Water-surface elevations are measured using an array of acoustic transducers in the laboratory and using laser scanning in field situations. Water-surface velocities are based on using particle image velocimetry or other machine vision techniques on infrared video of the water surface. Using spatial and temporal averaging, results from these methods provide information that can be used to develop estimates of discharge for flows over known bathymetry. Making such estimates requires relating water-surface velocities to vertically averaged velocities; the methods here use standard relations. To examine where these relations break down, laboratory data for flows over simple bumps of three amplitudes are evaluated. As anticipated, discharges determined from surface information can have large errors where nonhydrostatic effects are large. In addition to investigating and characterizing this potential error in estimating discharge, a simple method for correction of the issue is presented. With a simple correction based on bed gradient along the flow direction, remotely sensed estimates of discharge appear to be viable.
Simple Technique for Dark-Field Photography of Immunodiffusion Bands
Jensh, Ronald P.; Brent, Robert L.
1969-01-01
A simple dark-field photographic technique was developed which enables laboratory personnel with minimal photographic training to easily record antigen-antibody patterns on immunodiffusion plates. Images PMID:4979944
Are we drunk yet? Motor versus cognitive cues of subjective intoxication.
Celio, Mark A; Usala, Julie M; Lisman, Stephen A; Johansen, Gerard E; Vetter-O'Hagen, Courtney S; Spear, Linda P
2014-02-01
Perception of alcohol intoxication presumably plays an important role in guiding behavior during a current drinking episode. Yet, there has been surprisingly little investigation of what aspects associated with intoxication are used by individuals to attribute their level of intoxication. Building on recent laboratory-based findings, this study employed a complex field-based design to explore the relative contributions of motor performance versus cognitive performance-specifically executive control-on self-attributions of intoxication. Individuals recruited outside of bars (N = 280; mean age = 22; range: 18 to 32) completed a structured interview, self-report questionnaire, and neuropsychological testing battery, and provided a breath alcohol concentration (BrAC) sample. Results of a multiple linear regression analysis demonstrated that current level of subjective intoxication was associated with current alcohol-related stimulant effects, current sedative effects, and current BrAC. After controlling for the unique variance accounted for by these factors, subjective intoxication was better predicted by simple motor speed, as indexed by performance on the Finger Tapping Test, than by executive control, as indexed by performance on the Trail Making Test. These results-generated from data collected in a naturally occurring setting-support previous findings from a more traditional laboratory-based investigation, thus illustrating the iterative process of linking field methodology and controlled laboratory experimentation. Copyright © 2013 by the Research Society on Alcoholism.
Kairisto, V; Poola, A
1995-01-01
GraphROC for Windows is a program for clinical test evaluation. It was designed for the handling of large datasets obtained from clinical laboratory databases. In the user interface, graphical and numerical presentations are combined. For simplicity, numerical data is not shown unless requested. Relevant numbers can be "picked up" from the graph by simple mouse operations. Reference distributions can be displayed by using automatically optimized bin widths. Any percentile of the distribution with corresponding confidence limits can be chosen for display. In sensitivity-specificity analysis, both illness- and health-related distributions are shown in the same graph. The following data for any cutoff limit can be shown in a separate click window: clinical sensitivity and specificity with corresponding confidence limits, positive and negative likelihood ratios, positive and negative predictive values and efficiency. Predictive values and clinical efficiency of the cutoff limit can be updated for any prior probability of disease. Receiver Operating Characteristics (ROC) curves can be generated and combined into the same graph for comparison of several different tests. The area under the curve with corresponding confidence interval is calculated for each ROC curve. Numerical results of analyses and graphs can be printed or exported to other Microsoft Windows programs. GraphROC for Windows also employs a new method, developed by us, for the indirect estimation of health-related limits and change limits from mixed distributions of clinical laboratory data.
Dawson, Arthur; Loving, Richard T; Gordon, Robert M; Abel, Susan L; Loewy, Derek; Kripke, Daniel F; Kline, Lawrence E
2015-06-30
In its guidelines on the use of portable monitors to diagnose obstructive sleep apnoea, the American Academy of Sleep Medicine endorses home polygraphy with type III devices recording at a minimum airflow the respiratory effort and pulse oximetry, but advises against simple pulse oximetry. However, oximetry is widely available and simple to use in the home. This study was designed to compare the ability of the oxygen desaturation index (ODI) based on oximetry alone with a stand-alone pulse oximeter (SPO) and from the oximetry channel of the ApneaLink Plus (ALP), with the respiratory disturbance index (RDI) based on four channels from the ALP to predict the apnoea-hypopnoea index (AHI) from laboratory polysomnography. Cross-sectional diagnostic accuracy study. Sleep medicine practice of a multispecialty clinic. Patients referred for laboratory polysomnography with suspected sleep apnoea. We enrolled 135 participants with 123 attempting the home sleep testing and 73 having at least 4 hours of satisfactory data from SPO and ALP. Participants had home testing performed simultaneously with both a SPO and an ALP. The 2 oximeter probes were worn on different fingers of the same hand. The ODI for the SPO was calculated using Profox software (ODI(SOX)). For the ALP, RDI and ODI were calculated using both technician scoring (RDI(MAN) and ODI(MAN)) and the ALP computer scoring (RDI(RAW) and ODI(RAW)). The receiver-operator characteristic areas under the curve for AHI ≥ 5 were RDI(MAN) 0.88 (95% confidence limits 0.81-0.96), RDI(RAW) 0.86 (0.76-0.94), ODI(MAN) 0.86 (0.77-0.95), ODI(RAW) 0.84 (0.75-0.93) and ODI(SOX) 0.83 (0.73-0.93). We conclude that the RDI and the ODI, measured at home on the same night, give similar predictions of the laboratory AHI, measured on a different night. The differences between the two methods are small compared with the reported night-to-night variation of the AHI. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Technical Reports Server (NTRS)
1979-01-01
The photos show automobile engines being tested for nitrous oxide emissions, as required by the Environmental Protection Agency (EPA), at the Research and Engineering Division of Ford Motor Company, Dearborn. Michigan. NASA technical information helped the company develop a means of calculating emissions test results. Nitrous oxide emission readings vary with relative humidity in the test facility. EPA uses a standard humidity measurement, but the agency allows manufacturers to test under different humidity conditions, then apply a correction factor to adjust the results to the EPA standard. NASA's Dryden Flight Research Center developed analytic equations which provide a simple, computer-programmable method of correcting for humidity variations. A Ford engineer read a NASA Tech Brief describing the Dryden development and requested more detailed information in the form of a technical support package, which NASA routinely supplies to industry on request. Ford's Emissions Test Laboratory now uses the Dryden equations for humidity-adjusted emissions data reported to EPA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John; Jiang, Hao
2016-01-12
To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at the Oak Ridge National Laboratory (ORNL) and is described fully in US Patent Application 20060070455, “Expanded plug method for developing circumferential mechanical properties of tubular materials.” This method is designed for testing fuel rod cladding ductility in a hot cell using an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are themore » simplicity of measuring the test component assembly in the hot cell and the direct measurement of the specimen’s strain. It was also found that cladding strength could be determined from the test results.« less
Test techniques for determining laser ranging system performance
NASA Technical Reports Server (NTRS)
Zagwodzki, T. W.
1981-01-01
Procedures and results of an on going test program intended to evaluate laser ranging system performance levels in the field as well as in the laboratory are summarized. Tests show that laser ranging system design requires consideration of time biases and RMS jitters of individual system components. All simple Q switched lasers tested were found to be inadequate for 10 centimeter ranging systems. Timing discriminators operating over a typical 100:1 dynamic signal range may introduce as much as 7 to 9 centimeters of range bias. Time interval units commercially available today are capable of half centimeter performance and are adequate for all field systems currently deployed. Photomultipliers tested show typical tube time biases of one centimeter with single photoelectron transit time jitter of approximately 10 centimeters. Test results demonstrate that NASA's Mobile Laser Ranging System (MOBLAS) receiver configuration is limiting system performance below the 100 photoelectron level.
Fidler, Sarah; Lewis, Heather; Meyerowitz, Jodi; Kuldanek, Kristin; Thornhill, John; Muir, David; Bonnissent, Alice; Timson, Georgina; Frater, John
2017-10-20
There is a global need for HIV viral load point-of-care (PoC) assays to monitor patients receiving antiretroviral therapy. UNICORN was the first study of an off-label protocol using whole blood finger-prick samples tested with and without a simple three minute spin using a clinic-room microcentrifuge. Two PoC assays were evaluated in 40 HIV-positive participants, 20 with detectable and 20 with undetectable plasma viral load (pVL) (<20 copies/ml). Using 100 µl finger-prick blood samples, the Cepheid Xpert HIV-1 Viral Load and HIV-1 Qual cartridges were compared with laboratory pVL assessment (TaqMan, Roche). For participants with undetectable viraemia by TaqMan, there was poor concordance without centrifugation with the TaqMan platform with only 40% 'undetectable' using Xpert VL and 25% 'not detected' using the Qual assay. After a 3 minute spin, 100% of samples were undetectable using either assay, showing full concordance with the TaqMan assay. Defining a lower limit of detection of 1000 copies/ml when including a spin, there was 100% concordance with the TaqMan platform with strong correlation (rho 0.95 and 0.94; p < 0.0001 for both assays). When including a simple microcentrifugation step, finger-prick PoC testing was a quick and accurate approach for assessing HIV viraemia, with excellent concordance with validated laboratory approaches.
Using Mouse Mammary Tumor Cells to Teach Core Biology Concepts: A Simple Lab Module.
McIlrath, Victoria; Trye, Alice; Aguanno, Ann
2015-06-18
Undergraduate biology students are required to learn, understand and apply a variety of cellular and molecular biology concepts and techniques in preparation for biomedical, graduate and professional programs or careers in science. To address this, a simple laboratory module was devised to teach the concepts of cell division, cellular communication and cancer through the application of animal cell culture techniques. Here the mouse mammary tumor (MMT) cell line is used to model for breast cancer. Students learn to grow and characterize these animal cells in culture and test the effects of traditional and non-traditional chemotherapy agents on cell proliferation. Specifically, students determine the optimal cell concentration for plating and growing cells, learn how to prepare and dilute drug solutions, identify the best dosage and treatment time course of the antiproliferative agents, and ascertain the rate of cell death in response to various treatments. The module employs both a standard cell counting technique using a hemocytometer and a novel cell counting method using microscopy software. The experimental procedure lends to open-ended inquiry as students can modify critical steps of the protocol, including testing homeopathic agents and over-the-counter drugs. In short, this lab module requires students to use the scientific process to apply their knowledge of the cell cycle, cellular signaling pathways, cancer and modes of treatment, all while developing an array of laboratory skills including cell culture and analysis of experimental data not routinely taught in the undergraduate classroom.
Guidelines for European workplace drug testing in oral fluid.
Cooper, Gail; Moore, Christine; George, Claire; Pichini, Simona
2011-05-01
Over the past decade, oral fluid has established itself as a robust testing matrix for monitoring drug use or misuse. Commercially available collection devices provide opportunities to collect and test oral fluid by the roadside and near-patient testing with both clinical and criminal justice applications. One of the main advantages of oral fluid relates to the collection of the matrix which is non-invasive, simple, and can be carried out under direct observation making it ideal for workplace drug testing. Laboratories offering legally defensible oral fluid workplace drug testing must adhere to national and international quality standards (ISO/IEC 17025); however, these standards do not address issues specific to oral fluid testing. The European Workplace Drug Testing Society (EWDTS) recognizes the importance of providing best practice guidelines to organizations offering testing and those choosing to use oral fluid drug testing to test their employees. The aim of this paper is to present the EWDTS guidelines for oral fluid workplace drug testing. Copyright © 2011 John Wiley & Sons, Ltd.
ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection.
Sun, Steven; Yang, Minghui; Kostov, Yordan; Rasooly, Avraham
2010-08-21
A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.
ERIC Educational Resources Information Center
FIEL, NICHOLAS J.; JOHNSTON, RAYMOND F.
A PREPARATION LABORATORY WAS DESIGNED TO FAMILIARIZE STUDENTS IN ADVANCED MAMMALIAN PHYSIOLOGY WITH LABORATORY SKILLS AND TECHNIQUES AND THUS SHORTEN THE TIME THEY SPEND IN SETTING UP ACTUAL EXPERIMENTS. THE LABORATORY LASTS 30 MINUTES, IS FLEXIBLE AND SIMPLE OF OPERATION, AND DOES NOT REQUIRE A PROFESSOR'S PRESENCE. THE BASIC TRAINING UNIT IS THE…
ERIC Educational Resources Information Center
Butcher, Samuel S.; And Others
1985-01-01
Part I of this paper (SE 538 295) described a simple model for estimating laboratory concentrations of gas phase pollutants. In this part, the measurement of ventilation rates and applications of the model are discussed. The model can provide a useful starting point in planning for safer instructional laboratories. (JN)
[A simple apparatus for controllable drinking without leaks for laboratory rats].
Huber, D
1989-01-01
A simple device for watering laboratory rats is described. It has been made by using commercially available glass tubing (DURAN 50) with outside diameters of 8 mm, 6 mm, and 3 mm, respectively. The tubes were fused at their tips. The drinking tube is fitted to a rubber stopper at the top of a 250 ml soft polyethylene bottle. By this way water-soluble drugs can be administered to rats with high precision.
Factors influencing the latency of simple reaction time
Woods, David L.; Wyma, John M.; Yund, E. William; Herron, Timothy J.; Reed, Bruce
2015-01-01
Simple reaction time (SRT), the minimal time needed to respond to a stimulus, is a basic measure of processing speed. SRTs were first measured by Francis Galton in the 19th century, who reported visual SRT latencies below 190 ms in young subjects. However, recent large-scale studies have reported substantially increased SRT latencies that differ markedly in different laboratories, in part due to timing delays introduced by the computer hardware and software used for SRT measurement. We developed a calibrated and temporally precise SRT test to analyze the factors that influence SRT latencies in a paradigm where visual stimuli were presented to the left or right hemifield at varying stimulus onset asynchronies (SOAs). Experiment 1 examined a community sample of 1469 subjects ranging in age from 18 to 65. Mean SRT latencies were short (231, 213 ms when corrected for hardware delays) and increased significantly with age (0.55 ms/year), but were unaffected by sex or education. As in previous studies, SRTs were prolonged at shorter SOAs and were slightly faster for stimuli presented in the visual field contralateral to the responding hand. Stimulus detection time (SDT) was estimated by subtracting movement initiation time, measured in a speeded finger tapping test, from SRTs. SDT latencies averaged 131 ms and were unaffected by age. Experiment 2 tested 189 subjects ranging in age from 18 to 82 years in a different laboratory using a larger range of SOAs. Both SRTs and SDTs were slightly prolonged (by 7 ms). SRT latencies increased with age while SDT latencies remained stable. Precise computer-based measurements of SRT latencies show that processing speed is as fast in contemporary populations as in the Victorian era, and that age-related increases in SRT latencies are due primarily to slowed motor output. PMID:25859198
Screening and syndromic approaches to identify gonorrhea and chlamydial infection among women.
Sloan, N L; Winikoff, B; Haberland, N; Coggins, C; Elias, C
2000-03-01
The standard diagnostic tools to identify sexually transmitted infections are often expensive and have laboratory and infrastructure requirements that make them unavailable to family planning and primary health-care clinics in developing countries. Therefore, inexpensive, accessible tools that rely on symptoms, signs, and/or risk factors have been developed to identify and treat reproductive tract infections without the need for laboratory diagnostics. Studies were reviewed that used standard diagnostic tests to identify gonorrhea and cervical chlamydial infection among women and that provided adequate information about the usefulness of the tools for screening. Aggregation of the studies' results suggest that risk factors, algorithms, and risk scoring for syndromic management are poor indicators of gonorrhea and chlamydial infection in samples of both low and high prevalence and, consequently, are not effective mechanisms with which to identify or manage these conditions. The development and evaluation of other approaches to identify gonorrhea and chlamydial infections, including inexpensive and simple laboratory screening tools, periodic universal treatment, and other alternatives must be given priority.
A Simple Decontamination Approach Using Hydrogen ...
Journal article To evaluate the use of relatively low levels of hydrogen peroxide vapor (HPV) for the inactivation of Bacillus anthracis spores within an indoor environment. Methods and Results: Laboratory-scale decontamination tests were conducted using bacterial spores of both B. anthracis Ames and Bacillus atrophaeus inoculated onto several types of materials. Pilot-scale tests were also conducted using a larger chamber furnished as an indoor office. Commercial off-the-shelf (COTS) humidifiers filled with aqueous solutions of 3% or 8% hydrogen peroxide were used to generate the HPV inside the mock office. The spores were exposed to the HPV for periods ranging from 8 hours up to one week. Conclusions: Four to seven day exposures to low levels of HPV (average air concentrations of approximately 5-10 parts per million) were effective in inactivating B. anthracis spores on multiple materials. The HPV can be generated with COTS humidifiers and household H2O2 solutions. With the exception of one test/material, B. atrophaeus spores were equally or more resistant to HPV inactivation compared to those from B. anthracis Ames. Significance and Impact of Study: This simple and effective decontamination method is another option that could be widely applied in the event of a B. anthracis spore release.
Development of an immunochromatographic strip for simple detection of penicillin-binding protein 2'.
Matsui, Hidehito; Hanaki, Hideaki; Inoue, Megumi; Akama, Hiroyuki; Nakae, Taiji; Sunakawa, Keisuke; Omura, Satoshi
2011-02-01
Infections with methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-resistant coagulase-negative Staphylococcus (MR-CNS) are a serious problem in hospitals because these bacteria produce penicillin-binding protein 2' (PBP2' or PBP2a), which shows low affinity to β-lactam antibiotics. Furthermore, the bacteria show resistance to a variety of antibiotics. Identification of these pathogens has been carried out mainly by the oxacillin susceptibility test, which takes several days to produce a reliable result. We developed a simple immunochromatographic test that enabled the detection of PBP2' within about 20 min. Anti-PBP2' monoclonal antibodies were produced by a hybridoma of recombinant PBP2' (rPBP2')-immunized mouse spleen cells and myeloma cells. The monoclonal antibodies reacted only with PBP2' of whole-cell extracts and showed no detectable cross-reactivity with extracts from other bacterial species tested so far. One of the monoclonal antibodies was conjugated with gold colloid particles, which react with PBP2', and another antibody was immobilized on a nitrocellulose membrane, which captures the PBP2'-gold colloid particle complex on a nitrocellulose strip. This strip was able to detect 1.0 ng of rPBP2' or 2.8 × 10(5) to 1.7 × 10(7) CFU of MRSA cells. The cross-reactivity test using 15 bacterial species and a Candida albicans strain showed no detectable false-positive results. The accuracy of this method in the detection of MRSA and MR-CNS appeared to be 100%, compared with the results obtained by PCR amplification of the PBP2' gene, mecA. This newly developed immunochromatographic test can be used for simple and accurate detection of PBP2'-producing cells in clinical laboratories.
Ferraz, Erica; Arruda, Luisa Karla de Paula; Bagatin, Ericson; Martinez, Edson Z; Cetlin, Andrea A; Simoneti, Christian S; Freitas, Amanda S; Martinez, José A B; Borges, Marcos C; Vianna, Elcio O
2013-01-01
OBJECTIVE: Subjects exposed to laboratory animals are at a heightened risk of developing respiratory and allergic diseases. These diseases can be prevented by simple measures such as the use of personal protective equipment. We report here the primary findings of the Laboratory Animals and Respiratory Allergies Study regarding the prevalence of allergic diseases among laboratory animal workers, the routine use of preventive measures in laboratories and animal facilities, and the need for prevention programs. METHODS: Animal handlers and non-animal handlers from 2 Brazilian universities (University of São Paulo and State University of Campinas) answered specific questionnaires to assess work conditions and symptoms. These subjects also underwent spirometry, a bronchial challenge test with mannitol, and skin prick tests for 11 common allergens and 5 occupational allergens (rat, mouse, guinea pig, hamster, and rabbit). RESULTS: Four hundred fifty-five animal handlers (32±10 years old [mean±SD], 209 men) and 387 non-animal handlers (33±11 years old, 121 men) were evaluated. Sensitization to occupational allergens was higher among animal handlers (16%) than non-animal handlers (3%, p<0.01). Accessibility to personal protective equipment was measured at 85% (median, considering 73 workplaces of the animal handler group). Nineteen percent of the animal handlers indicated that they wear a respirator at all times while handling animals or working in the animal room, and only 25% of the animal handlers had received an orientation about animal-induced allergies, asthma, or rhinitis. CONCLUSION: In conclusion, our data indicate that preventive programs are necessary. We suggest providing individual advice to workers associated with institutional programs to promote a safer work environment. PMID:23778494
Comparative evaluation of power factor impovement techniques for squirrel cage induction motors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spee, R.; Wallace, A.K.
1992-04-01
This paper describes the results obtained from a series of tests of relatively simple methods of improving the power factor of squirrel-cage induction motors. The methods, which are evaluated under controlled laboratory conditions for a 10-hp, high-efficiency motor, include terminal voltage reduction; terminal static capacitors; and a floating'' winding with static capacitors. The test results are compared with equivalent circuit model predictions that are then used to identify optimum conditions for each of the power factor improvement techniques compared with the basic induction motor. Finally, the relative economic value, and the implications of component failures, of the three methods aremore » discussed.« less
Stobbs, L. W.
1990-01-01
In this paper, plans are given for the construction of an inexpensive enzyme-linked immunosorbent assay plate washer from readily available materials. The wash unit uses an intermittent wash cycle based on a wash manifold cycling over the microdilution plates for a predetermined time. Laboratory tests showed that the unit provided reliable, rapid washing of plates with tap water, with no detectable contamination between wells. Substrate absorbance values for test samples from machine-washed plates were equal to or greater than absorbance values for corresponding samples from plates washed manually by an accepted protocol, by using either enzyme-linked immunosorbent assay wash buffer or tap water. Images PMID:16348216
Rolewicz, M; Rusek, P; Borowik, K
2018-06-15
The article presents research results on obtaining phosphorus granulated fertilizers on the basis of microbiologically activated sewage sludge ashes, ground bones and dried blood from meat industry. Granulation tests were carried out using a laboratory pan granulator as well as on an experimental pilot plant. The aim of the studies was to select the proper composition of the mixture of raw materials and binding agents to obtain granulated fertilizers from waste materials such as MSSA and MBM and bacteria lyophilisate. Obtained fertilizer samples were subjected to physical tests (granulation tests etc.) and quality assessment. The tests confirmed that it was possible to produce granulated phosphate fertilizers using the Bacillus megaterium for solubilization of phosphorus in a simple process. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, Guirong; Yu, Xia; Liang, Qian; Chen, Suting; Wilson, Stuart; Huang, Hairong
2013-01-01
The timely differentiation of Mycobacterium tuberculosis complex (MTC) and non-tubercular mycobacterium (NTM) species is urgently needed in patient care since the routine laboratory method is time consuming and cumbersome. An easy and cheap method which can successfully distinguish MTC from NTM was established and evaluated. 38 mycobacterial type and reference strains and 65 clinical isolates representing 10 species of mycobacterium were included in this study. Metabolites of p-nitrobenzoic acid (PNB) reduction were identified using liquid chromatography and tandem mass spectrometry (LC/MS/MS). A spectrophotometric method was developed to detect these metabolites, which was evaluated on a number of MTC and NTM species. All of the tested NTM species and strains reduced PNB to p-aminobenzoic acid (PABA), while none of the MTC strains showed a similar activity. Spectrophotometric detection of PABA had 100% sensitivity and specificity for MTC and NTM differentiation among the type strains and the clinical isolates tested. PABA was identified as one of the metabolites of PNB reduction. All the tested NTM species metabolized PNB to PABA whereas the MTC members lacked this activity. A simple, specific and cost-effective method based on PABA production was established in order to discriminate MTC from NTM from cultured organisms. PMID:24260497
Montoliu, Lluís
2012-06-01
The analysis of transgenic and knockout mice always involves the establishment of matings with individuals carrying different loci, segregating independently, whose presence is expected among the progeny, according to a Mendelian distribution. The appearance of distorted inheritance ratios suggests the existence of unexpected lethal or sub-lethal phenotypes associated with some genotypes. These situations are common in a number of cases, including: testing transgenic founder mice for germ-line transmission of their transgenes; setting up heterozygous crosses to obtain homozygous individuals, both for transgenic and knockout mice; establishing matings between floxed mouse lines and suitable cre transgenic mouse lines, etc. The Pearson's χ(2) test can be used to assess the significance of the observed frequencies of genotypes/phenotypes in relation to the expected values, in order to determine whether the observed cases fit the expected distribution. Here, I describe a simple Excel workbook to compare the observed and expected distributions of genotypes/phenotypes in transgenic and knockout mouse crosses involving up to three unlinked loci by means of a χ(2) test. The file is freely available for download from my laboratory's web page at: http://www.cnb.csic.es/~montoliu/Mendel.xls .
A simple micro-photometric method for urinary iodine determination.
Grimm, Gabriele; Lindorfer, Heidelinde; Kieweg, Heidi; Marculescu, Rodrig; Hoffmann, Martha; Gessl, Alois; Sager, Manfred; Bieglmayer, Christian
2011-10-01
Urinary iodide concentration (UIC) is useful to evaluate nutritional iodine status. In clinical settings UIC helps to exclude blocking of the thyroid gland by excessive endogenous iodine, if diagnostic or therapeutic administration of radio-iodine is indicated. Therefore, this study established a simple test for the measurement of UIC. UIC was analyzed in urine samples of 200 patients. Samples were pre-treated at 95°C for 45 min with ammonium persulfate in a thermal cycler, followed by a photometric Sandell-Kolthoff reaction (SK) carried out in microtiter plates. For method comparison, UIC was analyzed in 30 samples by inductivity coupled plasma mass spectro-metry (ICP-MS) as a reference method. Incubation conditions were optimized concerning recovery. The photometric test correlated well to the reference method (SK=0.91*ICP-MS+1, r=0.962) and presented with a functional sensitivity of 20 μg/L. UIC of patient samples ranged from <20 to 750 μg/L (median 110 μg/L); 90% of the urine samples had iodide concentrations below 210 μg/L. The modified SK-test takes approximately 90 min for analyses of 20 urine samples compared with 27 h for ICP-MS. The photometric test provides satisfactory results and can be performed with the basic equipment of a clinical laboratory.
ERIC Educational Resources Information Center
Straulino, S.; Bonechi, L.
2010-01-01
Two lenses make it possible to create a simple telescope with quite large magnification. The set-up is very simple and can be reproduced in schools, provided the laboratory has a range of lenses with different focal lengths. In this article, the authors adopt the Keplerian configuration, which is composed of two converging lenses. This instrument,…
Rule Systems for Runtime Verification: A Short Tutorial
NASA Astrophysics Data System (ADS)
Barringer, Howard; Havelund, Klaus; Rydeheard, David; Groce, Alex
In this tutorial, we introduce two rule-based systems for on and off-line trace analysis, RuleR and LogScope. RuleR is a conditional rule-based system, which has a simple and easily implemented algorithm for effective runtime verification, and into which one can compile a wide range of temporal logics and other specification formalisms used for runtime verification. Specifications can be parameterized with data, or even with specifications, allowing for temporal logic combinators to be defined. We outline a number of simple syntactic extensions of core RuleR that can lead to further conciseness of specification but still enabling easy and efficient implementation. RuleR is implemented in Java and we will demonstrate its ease of use in monitoring Java programs. LogScope is a derivation of RuleR adding a simple very user-friendly temporal logic. It was developed in Python, specifically for supporting testing of spacecraft flight software for NASA’s next 2011 Mars mission MSL (Mars Science Laboratory). The system has been applied by test engineers to analysis of log files generated by running the flight software. Detailed logging is already part of the system design approach, and hence there is no added instrumentation overhead caused by this approach. While post-mortem log analysis prevents the autonomous reaction to problems possible with traditional runtime verification, it provides a powerful tool for test automation. A new system is being developed that integrates features from both RuleR and LogScope.
A Simple Optical Waveguide Experiment.
ERIC Educational Resources Information Center
Phelps, J.; Sambles, J. R.
1989-01-01
Describes a thin film rectangular dielectric waveguide and its laboratory use. Discusses the theory of uniaxial thin film waveguides with mathematical expressions and the laboratory procedures for a classroom experiment with diagrams. (Author/YP)
Determination of Absolute Zero Using a Computer-Based Laboratory
ERIC Educational Resources Information Center
Amrani, D.
2007-01-01
We present a simple computer-based laboratory experiment for evaluating absolute zero in degrees Celsius, which can be performed in college and undergraduate physical sciences laboratory courses. With a computer, absolute zero apparatus can help demonstrators or students to observe the relationship between temperature and pressure and use…
ERIC Educational Resources Information Center
Vullo, Diana L.; Wachsman, Monica B.
2005-01-01
This laboratory experiment was designed for Chemistry, Food Technology, Biology, and Chemical Engineering undergraduate students. This laboratory experience shows the advantages of immobilized bakery yeasts in ethanol production by alcoholic fermentation. The students were able to compare the ethanol production yields by free or calcium alginate…
A Laboratory Course in Clinical Biochemistry Emphasizing Interest and Relevance
ERIC Educational Resources Information Center
Schwartz, Peter L.
1975-01-01
Ten laboratory experiments are described which are used in a successful clinical biochemistry laboratory course (e.g. blood alcohol, glucose tolerance, plasma triglycerides, coronary risk index, gastric analysis, vitamin C and E). Most of the experiments are performed on the students themselves using simple equipment with emphasis on useful…
Garcia, Marcos; Römbke, Jörg; de Brito, Marcus Torres; Scheffczyk, Adam
2008-05-01
Little research has been performed on the impact of pesticides on earthworms under tropical conditions. Taking into consideration the often-limited resources in tropical countries, simple screening tests are needed. Therefore, it was investigated whether three pesticides relevant for the Brazilian Amazon (benomyl, carbendazim, lambda-cyhalothrin) affect the avoidance behavior of the earthworm Eisenia fetida. The tests were performed for two days according to ISO guideline 17512 but were adapted to tropical conditions (i.e. test substrate, test organism and temperature). The results indicate that this test gives reproducible and reliable results. Toxicity values (NOEC, EC50) are lower than those determined in 14 day-acute mortality tests and are approximately in the same range such as those found in 56 day-chronic reproduction tests with the same earthworm species, which were performed in parallel. Therefore, the use of the earthworm avoidance tests is recommended as a screening tool for the risk assessment of pesticides.
Jezova, D; Hlavacova, N; Dicko, I; Solarikova, P; Brezina, I
2016-07-01
Repeated or chronic exposure to stressors is associated with changes in neuroendocrine responses depending on the type, intensity, number and frequency of stress exposure as well as previous stress experience. The aim of the study was to test the hypothesis that salivary cortisol and cardiovascular responses to real-life psychosocial stressors related to public performance can cross-adapt with responses to psychosocial stress induced by public speech under laboratory setting. The sample consisted of 22 healthy male volunteers, which were either actors, more precisely students of dramatic arts or non-actors, students of other fields. The stress task consisted of 15 min anticipatory preparation phase and 15 min of public speech on an emotionally charged topic. The actors, who were accustomed to public speaking, responded with a rise in salivary cortisol as well as blood pressure to laboratory public speech. The values of salivary cortisol, systolic blood pressure and state anxiety were lower in actors compared to non-actors. Unlike non-actors, subjects with experience in public speaking did not show stress-induced rise in the heart rate. Evaluation of personality traits revealed that actors scored significantly higher in extraversion than the subjects in the non-actor group. In conclusion, neuroendocrine responses to real-life stressors in actors can partially cross-adapt with responses to psychosocial stress under laboratory setting. The most evident adaptation was at the level of heart rate responses. The public speech tasks may be of help in evaluation of the ability to cope with stress in real life in artists by simple laboratory testing.
Principles and implementations of electrolysis systems for water splitting
Xiang, Chengxiang; Papadantonakis, Kimberly M.; Lewis, Nathan S.
2016-02-12
Efforts to develop renewable sources of carbon-neutral fuels have brought a renewed focus to research and development of sunlight-driven water-splitting systems. Electrolysis of water to produce H 2 and O 2 gases is the foundation of such systems, is conceptually and practically simple, and has been practiced both in the laboratory and industrially for many decades. In this Focus article, the fundamentals of water splitting and practices which distinguish commercial water-electrolysis systems from simple laboratory-scale demonstrations are described.
A Simple Experiment Demonstrating the Allosteric Regulation of Yeast Pyruvate Kinase.
ERIC Educational Resources Information Center
Taber, Richard L.; Campbell, Angela; Spencer, Scott
1998-01-01
Explains the procedures used to determine the regulatory properties of yeast pyruvate kinase. Involves a partial purification using PEG precipitation that can be done in one laboratory period with simple equipment. (DDR)
Notes: Water Flow and Chemical Retardation in Soils: A Simple Effective Laboratory Demonstration.
ERIC Educational Resources Information Center
Bowman, R. S.; And Others
1988-01-01
Describes a laboratory demonstration that illustrates principles of miscible displacement and chemical retardation in soils. Discusses how the experimental apparatus can be constructed from readily available materials. (TW)
Simple Exploration Apparatus for the Introductory Physics Laboratory
ERIC Educational Resources Information Center
Campbell, Thomas C.
1977-01-01
Discusses the laboratory portion of a beginning noncalculus physics course that uses concrete examples of abstract concepts. Describes the use of coffee cans to explain oscillations and plastic darts to illustrate collisions. (MLH)
Visual conspicuity: a new simple standard, its reliability, validity and applicability.
Wertheim, A H
2010-03-01
A general standard for quantifying conspicuity is described. It derives from a simple and easy method to quantitatively measure the visual conspicuity of an object. The method stems from the theoretical view that the conspicuity of an object is not a property of that object, but describes the degree to which the object is perceptually embedded in, i.e. laterally masked by, its visual environment. First, three variations of a simple method to measure the strength of such lateral masking are described and empirical evidence for its reliability and its validity is presented, as are several tests of predictions concerning the effects of viewing distance and ambient light. It is then shown how this method yields a conspicuity standard, expressed as a number, which can be made part of a rule of law, and which can be used to test whether or not, and to what extent, the conspicuity of a particular object, e.g. a traffic sign, meets a predetermined criterion. An additional feature is that, when used under different ambient light conditions, the method may also yield an index of the amount of visual clutter in the environment. Taken together the evidence illustrates the methods' applicability in both the laboratory and in real-life situations. STATEMENT OF RELEVANCE: This paper concerns a proposal for a new method to measure visual conspicuity, yielding a numerical index that can be used in a rule of law. It is of importance to ergonomists and human factor specialists who are asked to measure the conspicuity of an object, such as a traffic or rail-road sign, or any other object. The new method is simple and circumvents the need to perform elaborate (search) experiments and thus has great relevance as a simple tool for applied research.
Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.
Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan
2018-01-01
Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.
Trip Report-Produced-Water Field Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Enid J.
2012-05-25
Los Alamos National Laboratory (LANL) conducted field testing of a produced-water pretreatment apparatus with assistance from faculty at the Texas A&M University (TAMU) protein separation sciences laboratory located on the TAMU main campus. The following report details all of the logistics surrounding the testing. The purpose of the test was to use a new, commercially-available filter media housing containing modified zeolite (surfactant-modified zeolite or SMZ) porous medium for use in pretreatment of oil and gas produced water (PW) and frac-flowback waters. The SMZ was tested previously in October, 2010 in a lab-constructed configuration ('old multicolumn system'), and performed well formore » removal of benzene, toluene, ethylbenzene, and xylenes (BTEX) from PW. However, a less-expensive, modular configuration is needed for field use. A modular system will allow the field operator to add or subtract SMZ filters as needed to accommodate site specific conditions, and to swap out used filters easily in a multi-unit system. This test demonstrated the use of a commercial filter housing with a simple flow modification and packed with SMZ for removing BTEX from a PW source in College Station, Texas. The system will be tested in June 2012 at a field site in Pennsylvania for treating frac-flowback waters. The goals of this test are: (1) to determine sorption efficiency of BTEX in the new configuration; and (2) to observe the range of flow rates, backpressures, and total volume treated at a given flow rate.« less
Detection of new HIV infections in a multicentre HIV antiretroviral pre-exposure prophylaxis trial.
Fransen, Katrien; de Baetselier, Irith; Rammutla, Elizabeth; Ahmed, Khatija; Owino, Frederick; Agingu, Walter; Venter, Gustav; Deese, Jen; Van Damme, Lut; Crucitti, Tania
2017-08-01
Monthly specimens collected from FEM-PrEP-a Phase III trial [1] were investigated for the detection of acute HIV (AHI) infection. To evaluate the efficiency of the study-specific HIV algorithm in detecting AHI, and the performance of each of the serological and molecular tests used in diagnosing new infections, and their contribution to narrowing the window period. A total of 83 pre-seroconversion specimens from 61 seroconverters from the FEM-PrEP trial were further analyzed in a sub-study. During the trial, HIV seroconversion was diagnosed on site using a testing algorithm with simple/rapid tests (SRTs) and confirmed with a gold standard testing algorithm (see short communication: Fig. 1). The infection date was determined more accurately by the use of standard ELISAs and Nucleic Acid Amplification Tests (NAAT) in a look-back procedure. For this sub-study, the international central laboratory repeated the study algorithm using SRTs. A total of 83 pre-seroconversions specimens from 61 seroconverters were analyzed in a look-back procedure. RNA was detected in 35/61 seroconverters at the visit before the seroconversion visit as determined at the study sites. Four seroconversion dates were inaccurate at one study site as the international central laboratory detected the HIV infection one visit earlier using the same test algorithm. Using the gold standard, an additional seroconversion was detected at an earlier visit. The combined antigen/antibody and the single antigen test had a higher sensitivity compared to the SRTs in detecting acute infections. In the FEM-PrEP trial, the international central laboratory detected a small number of seroconversions one month earlier than the study sites using the same study algorithm. Standard tests are still the most sensitive tests in detecting pre-seroconversion or acute HIV infection, but they are costly, time consuming and not recommended for use on-site in a clinical trial. Copyright © 2017 Elsevier B.V. All rights reserved.
A TeGM6-4r antigen-based immunochromatographic test (ICT) for animal trypanosomosis.
Nguyen, Thu-Thuy; Ruttayaporn, Ngasaman; Goto, Yasuyuki; Kawazu, Shin-ichiro; Sakurai, Tatsuya; Inoue, Noboru
2015-11-01
Animal trypanosomosis is a disease that is distributed worldwide which results in huge economic losses due to reduced animal productivity. Endemic regions are often located in the countryside where laboratory diagnosis is costly or inaccessible. The establishment of simple, effective, and accurate field tests is therefore of great interest to the farming and veterinary sectors. Our study aimed to develop a simple, rapid, and sensitive immunochromatographic test (ICT) for animal trypanosomosis utilizing the recombinant tandem repeat antigen TeGM6-4r, which is conserved amongst salivarian trypanosome species. In the specificity analysis, TeGM6-4r/ICT detected all of Trypanosoma evansi-positive controls from experimentally infected water buffaloes. As expected, uninfected controls tested negative. All sera samples collected from Tanzanian and Ugandan cattle that were Trypanosoma congolense- and/or Trypanosoma vivax-positive by microscopic examination of the buffy coat were found to be positive by the newly developed TeGM6-4r/ICT, which was comparable to results from TeGM6-4r/ELISA (kappa coefficient [κ] = 0.78). TeGM6/ICT also showed substantial agreement with ELISA using Trypanosoma brucei brucei (κ = 0.64) and T. congolense (κ = 0.72) crude antigen, suggesting the high potential of TeGM6-4r/ICT as a field diagnostic test, both for research purposes and on-site diagnosis of animal trypanosomosis.
Prediction of Frequency for Simulation of Asphalt Mix Fatigue Tests Using MARS and ANN
Fakhri, Mansour
2014-01-01
Fatigue life of asphalt mixes in laboratory tests is commonly determined by applying a sinusoidal or haversine waveform with specific frequency. The pavement structure and loading conditions affect the shape and the frequency of tensile response pulses at the bottom of asphalt layer. This paper introduces two methods for predicting the loading frequency in laboratory asphalt fatigue tests for better simulation of field conditions. Five thousand (5000) four-layered pavement sections were analyzed and stress and strain response pulses in both longitudinal and transverse directions was determined. After fitting the haversine function to the response pulses by the concept of equal-energy pulse, the effective length of the response pulses were determined. Two methods including Multivariate Adaptive Regression Splines (MARS) and Artificial Neural Network (ANN) methods were then employed to predict the effective length (i.e., frequency) of tensile stress and strain pulses in longitudinal and transverse directions based on haversine waveform. It is indicated that, under controlled stress and strain modes, both methods (MARS and ANN) are capable of predicting the frequency of loading in HMA fatigue tests with very good accuracy. The accuracy of ANN method is, however, more than MARS method. It is furthermore shown that the results of the present study can be generalized to sinusoidal waveform by a simple equation. PMID:24688400
Wadhwa, Ashutosh; Hickling, Graham J.; Eda, Shigetoshi
2012-01-01
Mycobacterial infections—tuberculosis (TB), bovine tuberculosis (bTB), and Johne's disease (JD)—are major infectious diseases of both human and animals. Methods presently in use for diagnosis of mycobacterial infections include bacterial culture, nucleic acid amplification, tuberculin skin test, interferon-γ assay, and serology. Serological tests have several advantages over other methods, including short turn-around time, relatively simple procedures, and low cost. However, current serodiagnostic methods for TB, bTB and JD exhibit low sensitivity and/or specificity. Recent studies that have aimed to develop improved serodiagnostic tests have mostly focused on identifying useful species-specific protein antigens. A review of recent attempts to improve diagnostic test performance indicates that the use of multiple antigens can improve the accuracy of serodiagnosis of these mycobacterial diseases. Mycobacteria also produce a variety of species-specific nonprotein molecules; however, only a few such molecules (e.g., cord factor and lipoarabinomannan) have so far been evaluated for their effectiveness as diagnostic antigens. For TB and bTB, there has been recent progress in developing laboratory-free diagnostic methods. New technologies such as microfluidics and “Lab-on-Chip” are examples of promising new technologies that can underpin development of laboratory-free diagnostic devices for these mycobacterial infections. PMID:22720192
Prediction of frequency for simulation of asphalt mix fatigue tests using MARS and ANN.
Ghanizadeh, Ali Reza; Fakhri, Mansour
2014-01-01
Fatigue life of asphalt mixes in laboratory tests is commonly determined by applying a sinusoidal or haversine waveform with specific frequency. The pavement structure and loading conditions affect the shape and the frequency of tensile response pulses at the bottom of asphalt layer. This paper introduces two methods for predicting the loading frequency in laboratory asphalt fatigue tests for better simulation of field conditions. Five thousand (5000) four-layered pavement sections were analyzed and stress and strain response pulses in both longitudinal and transverse directions was determined. After fitting the haversine function to the response pulses by the concept of equal-energy pulse, the effective length of the response pulses were determined. Two methods including Multivariate Adaptive Regression Splines (MARS) and Artificial Neural Network (ANN) methods were then employed to predict the effective length (i.e., frequency) of tensile stress and strain pulses in longitudinal and transverse directions based on haversine waveform. It is indicated that, under controlled stress and strain modes, both methods (MARS and ANN) are capable of predicting the frequency of loading in HMA fatigue tests with very good accuracy. The accuracy of ANN method is, however, more than MARS method. It is furthermore shown that the results of the present study can be generalized to sinusoidal waveform by a simple equation.
Lee, Jungmin; Durst, Robert W; Wrolstad, Ronald E
2005-01-01
This collaborative study was conducted to determine the total monomeric anthocyanin concentration by the pH differential method, which is a rapid and simple spectrophotometric method based on the anthocyanin structural transformation that occurs with a change in pH (colored at pH 1.0 and colorless at pH 4.5). Eleven collaborators representing commercial laboratories, academic institutions, and government laboratories participated. Seven Youden pair materials representing fruit juices, beverages, natural colorants, and wines were tested. The repeatability relative standard deviation (RSDr) varied from 1.06 to 4.16%. The reproducibility relative standard deviation (RSDR) ranged from 2.69 to 10.12%. The HorRat values were < or = 1.33 for all materials. The Study Director recommends that the method be adopted Official First Action.
Carotenaemia in children is common and benign: most can stay at home.
McGowan, R; Beattie, J; Galloway, P
2004-08-01
We identified children with elevated plasma carotene levels who attended the Royal Hospital for Sick Children, Glasgow, between July 1998 and April 2001 and carried out a retrospective case record review. Thirty-one children were identified (7 boys; 14 girls) with a median age at presentation of 13 months (range 7m- 11yrs). Twenty-seven (87%) children had simple diet-related carotenaemia and were well. In four cases the hypercarotenaemia reflected nutritional problems with associated failure to thrive. In only one case did the family doctor recognise the condition before referral. Many who attended hospital had laboratory confirmation of the benign diagnosis despite a clear dietary origin. Some had repeat laboratory tests to confirm resolution. Diet-related carotenaemia appears common in our community. The condition appears poorly recognised within primary care and hospital investigations may be over-enthusiastic.
Gaüzère, B-A; Ouellet, I; Nottebrock, D; Nied, J-C; Beya-Kadiebwe, B; Camara, A K; Camara, D; Camara, M L M; Camara, M; Soumah, A; Tounkara, M K; Monteil, V; Camara, A; Bauffe, F; Camara, A; Camara, I B; Simon, B; Jaspard, M; Tran-Minh, T; L'Hériteau, F
2016-10-01
Ebola virus disease (EVD) is associated with a high lethality rate even when the afflicted are provided with good support in an Ebola treatment center (ETC). Basic laboratory tests can help to better understand the pathophysiology of the disease, to guide treatment and to establish simple protocols and procedures tailored to the practice of medicine in the context of such precarious environment for caregivers. Based on a few clinical cases of patients treated in the ETC of Forecariah, Guinea, run by the French Red Cross, this article describes the difficult conditions associated with the provision of medical practice in this challenging environment, aiming to minimize the casualties in the EVD patient and to train the health staff.
Preparation of bone samples in the Gliwice Radiocarbon Laboratory for AMS radiocarbon dating.
Piotrowska, N; Goslar, T
2002-12-01
In the Gliwice Radiocarbon Laboratory, a system for preparation of samples for AMS dating has been built. At first it was used to produce graphite targets from plant macrofossils and sediments. In this study we extended its capabilities with the preparation of bones. We dealt with 3 methods; the first was the classical Longin method of collagen extraction, the second one included additional treatment of powdered bone in alkali solution, while in the third one carboxyl carbon was separated from amino acids obtained after hydrolysis of protein. The suitability of the methods was tested on 2 bone samples. Most of our samples gave ages > 40 kyr BP, suggesting good performance of the adapted methods, except for one sample prepared with simple Longin method. For routine preparation of bones we chose the Longin method with additional alkali treatment.
NASA Astrophysics Data System (ADS)
Attia, Khalid A. M.; El-Abasawi, Nasr M.; El-Olemy, Ahmed; Serag, Ahmed
2018-02-01
Five simple spectrophotometric methods were developed for the determination of simeprevir in the presence of its oxidative degradation product namely, ratio difference, mean centering, derivative ratio using the Savitsky-Golay filters, second derivative and continuous wavelet transform. These methods are linear in the range of 2.5-40 μg/mL and validated according to the ICH guidelines. The obtained results of accuracy, repeatability and precision were found to be within the acceptable limits. The specificity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. Furthermore, these methods were statistically comparable to RP-HPLC method and good results were obtained. So, they can be used for the routine analysis of simeprevir in quality-control laboratories.
Gentle, A R; Smith, G B
2014-10-20
Accurate solar and visual transmittances of materials in which surfaces or internal structures are complex are often not easily amenable to standard procedures with laboratory-based spectrophotometers and integrating spheres. Localized "hot spots" of intensity are common in such materials, so data on small samples is unreliable. A novel device and simple protocols have been developed and undergone validation testing. Simultaneous solar and visible transmittance and reflectance data have been acquired for skylight components and multilayer polycarbonate roof panels. The pyranometer and lux sensor setups also directly yield "light coolness" in lumens/watt. Sample areas must be large, and, although mainly in sheet form, some testing has been done on curved panels. The instrument, its operation, and the simple calculations used are described. Results on a subset of diffuse and partially diffuse materials with no hot spots have been cross checked using 150 mm integrating spheres with a spectrophotometer and the Air Mass 1.5 spectrum. Indications are that results are as good or better than with such spheres for transmittance, but reflectance techniques need refinement for some sample types.
NASA Astrophysics Data System (ADS)
Erdem, S. Sibel; Khan, Shazia; Palanisami, Akilan; Hasan, Tayyaba
2014-10-01
Antibiotic resistance (AR) is increasingly prevalent in low and middle income countries (LMICs), but the extent of the problem is poorly understood. This lack of knowledge is a critical deficiency, leaving local health authorities essentially blind to AR outbreaks and crippling their ability to provide effective treatment guidelines. The crux of the problem is the lack of microbiology laboratory capacity available in LMICs. To address this unmet need, we demonstrate a rapid and simple test of β-lactamase resistance (the most common form of AR) that uses a modified β-lactam structure decorated with two fluorophores quenched due to their close proximity. When the β-lactam core is cleaved by β-lactamase, the fluorophores dequench, allowing assay speeds of 20 min to be obtained with a simple, streamlined protocol. Furthermore, by testing in competition with antibiotics, the β-lactamase-associated antibiotic susceptibility can also be extracted. This assay can be easily implemented into standard lab work flows to provide near real-time information of β-lactamase resistance, both for epidemiological purposes as well as individualized patient care.
Wang, Jianchang; Liu, Libing; Wang, Jinfeng; Sun, Xiaoxia; Yuan, Wanzhe
2017-01-01
Feline herpesvirus 1 (FHV-1), an enveloped dsDNA virus, is one of the major pathogens of feline upper respiratory tract disease (URTD) and ocular disease. Currently, polymerase chain reaction (PCR) remains the gold standard diagnostic tool for FHV-1 infection but is relatively expensive, requires well-equipped laboratories and is not suitable for field tests. Recombinase polymerase amplification (RPA), an isothermal gene amplification technology, has been explored for the molecular diagnosis of infectious diseases. In this study, an exo-RPA assay for FHV-1 detection was developed and validated. Primers targeting specifically the thymidine kinase (TK) gene of FHV-1 were designed. The RPA reaction was performed successfully at 39°C and the results were obtained within 20 min. Using different copy numbers of recombinant plasmid DNA that contains the TK gene as template, we showed the detection limit of exo-RPA was 102 copies DNA/reaction, the same as that of real time PCR. The exo-RPA assay did not cross-detect feline panleukopenia virus, feline calicivirus, bovine herpesvirus-1, pseudorabies virus or chlamydia psittaci, a panel of pathogens important in feline URTD or other viruses in Alphaherpesvirinae, demonstrating high specificity. The assay was validated by testing 120 nasal and ocular conjunctival swabs of cats, and the results were compared with those obtained with real-time PCR. Both assays provided the same testing results in the clinical samples. Compared with real time PCR, the exo-RPA assay uses less-complex equipment that is portable and the reaction is completed much faster. Additionally, commercial RPA reagents in vacuum-sealed pouches can tolerate temperatures up to room temperature for days without loss of activity, suitable for shipment and storage for field tests. Taken together, the exo-RPA assay is a simple, fast and cost-effective alternative to real time PCR, suitable for use in less advanced laboratories and for field detection of FHV-1 infection.
Wang, Jianchang; Liu, Libing; Wang, Jinfeng; Sun, Xiaoxia; Yuan, Wanzhe
2017-01-01
Feline herpesvirus 1 (FHV-1), an enveloped dsDNA virus, is one of the major pathogens of feline upper respiratory tract disease (URTD) and ocular disease. Currently, polymerase chain reaction (PCR) remains the gold standard diagnostic tool for FHV-1 infection but is relatively expensive, requires well-equipped laboratories and is not suitable for field tests. Recombinase polymerase amplification (RPA), an isothermal gene amplification technology, has been explored for the molecular diagnosis of infectious diseases. In this study, an exo-RPA assay for FHV-1 detection was developed and validated. Primers targeting specifically the thymidine kinase (TK) gene of FHV-1 were designed. The RPA reaction was performed successfully at 39°C and the results were obtained within 20 min. Using different copy numbers of recombinant plasmid DNA that contains the TK gene as template, we showed the detection limit of exo-RPA was 102 copies DNA/reaction, the same as that of real time PCR. The exo-RPA assay did not cross-detect feline panleukopenia virus, feline calicivirus, bovine herpesvirus-1, pseudorabies virus or chlamydia psittaci, a panel of pathogens important in feline URTD or other viruses in Alphaherpesvirinae, demonstrating high specificity. The assay was validated by testing 120 nasal and ocular conjunctival swabs of cats, and the results were compared with those obtained with real-time PCR. Both assays provided the same testing results in the clinical samples. Compared with real time PCR, the exo-RPA assay uses less-complex equipment that is portable and the reaction is completed much faster. Additionally, commercial RPA reagents in vacuum-sealed pouches can tolerate temperatures up to room temperature for days without loss of activity, suitable for shipment and storage for field tests. Taken together, the exo-RPA assay is a simple, fast and cost-effective alternative to real time PCR, suitable for use in less advanced laboratories and for field detection of FHV-1 infection. PMID:28045956
Introducing Laboratory Safety.
ERIC Educational Resources Information Center
DeLorenzo, Ronald
1985-01-01
Presents a simple, 10-item quiz designed to make students aware that they must learn laboratory safety. The items include questions on acid/base accidents, several types of fire extinguishers, and safety glassses. Answers and some explanations are included. (DH)
Swezey, Robert; Shinn, Walter; Green, Carol; Drover, David R.; Hammer, Gregory B.; Schulman, Scott R.; Zajicek, Anne; Jett, David A.; Boss, Gerry R.
2013-01-01
Most hospital laboratories do not measure blood cyanide concentrations, and samples must be sent to reference laboratories. A simple method is needed for measuring cyanide in hospitals. The authors previously developed a method to quantify cyanide based on the high binding affinity of the vitamin B12 analog, cobinamide, for cyanide and a major spectral change observed for cyanide-bound cobinamide. This method is now validated in human blood, and the findings include a mean inter-assay accuracy of 99.1%, precision of 8.75% and a lower limit of quantification of 3.27 µM cyanide. The method was applied to blood samples from children treated with sodium nitroprusside and it yielded measurable results in 88 of 172 samples (51%), whereas the reference laboratory yielded results in only 19 samples (11%). In all 19 samples, the cobinamide-based method also yielded measurable results. The two methods showed reasonable agreement when analyzed by linear regression, but not when analyzed by a standard error of the estimate or paired t-test. Differences in results between the two methods may be because samples were assayed at different times on different sample types. The cobinamide-based method is applicable to human blood, and can be used in hospital laboratories and emergency rooms. PMID:23653045
ERIC Educational Resources Information Center
Felton, Daniel E.; Ederer, Martina; Steffens, Timothy; Hartzell, Patricia L.; Waynant, Kristopher V.
2018-01-01
Glyphosate (N-(phosphonomethyl)glycine) is the most widely used herbicide on earth. A simple assay to quantify glyphosate concentrations in environmental samples was developed as part of an interdisciplinary effort linking introductory laboratory courses in chemistry, biology, and microbiology. In this 3 h laboratory experiment, students used…
ERIC Educational Resources Information Center
Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay
2018-01-01
Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky…
How Efficient is a Laboratory Burner in Heating Water?
ERIC Educational Resources Information Center
Jansen, Michael P.
1997-01-01
Describes an experiment in which chemistry students determine the efficiency of a laboratory burner used to heat water. The reaction is assumed to be the complete combustion of methane, CH4. The experiment is appropriate for secondary school chemistry students familiar with heats of reaction and simple calorimetry. Contains pre-laboratory and…
A Laboratory Experiment for Rapid Determination of the Stability of Vitamin C
ERIC Educational Resources Information Center
Adem, Seid M.; Lueng, Sam H.; Elles, Lisa M. Sharpe; Shaver, Lee Alan
2016-01-01
Experiments in laboratory manuals intended for general, organic, and biological (GOB) chemistry laboratories include few opportunities for students to engage in instrumental methods of analysis. Many of these students seek careers in modern health-related fields where experience in spectroscopic techniques would be beneficial. A simple, rapid,…
Junka, Adam F; Żywicka, Anna; Szymczyk, Patrycja; Dziadas, Mariusz; Bartoszewicz, Marzena; Fijałkowski, Karol
2017-12-01
In the present article, we propose a simple Antibiofilm Dressing's Activity Measurement (A.D.A.M.) test that allows to check in vitro a dressing's suitability against biofilm-related wound infections. To perform the test, three agar discs are covered with biofilm formed by the tested pathogen after which they are assembled one over another in the form of an agar plug and placed in the well of a 24-well plate. The top disc is covered with the analyzed dressing and the entire set is incubated for 24h. During this time, the investigated antimicrobial substance is released from the dressing and penetrates to subsequent biofilm-covered agar discs. Biofilm reduction is measured using 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) spectrometric assay and the results are compared to untreated control samples (agar plug covered with biofilm and without the dressing/or with a passive dressing placed on the top disc). Furthermore, in order to standardize the differences in penetrability of the drugs released from active dressings the results can be expressed as a dimensionless value referred to as the Penetrability Index. In summary, A.D.A.M. test is simple, cheap, can be performed practically in every clinical laboratory and takes no more time than routine microbiological diagnostics. Apart from measuring the released drug's activity, the A.D.A.M. test allows to assess drug penetrability (across three agar discs), reflecting real wound conditions, where microbes are frequently hidden under the necrotic tissue or cloth. In conclusion, the A.D.A.M. test produces a high volume of data that, when analyzed, can provide a researcher with a valuable hint concerning the applicability of active dressings against specific biofilm pathogens in a particular setting. Copyright © 2017 Elsevier B.V. All rights reserved.
Environmental characterisation of coal mine waste rock in the field: an example from New Zealand
NASA Astrophysics Data System (ADS)
Hughes, J.; Craw, D.; Peake, B.; Lindsay, P.; Weber, P.
2007-08-01
Characterisation of mine waste rock with respect to acid generation potential is a necessary part of routine mine operations, so that environmentally benign waste rock stacks can be constructed for permanent storage. Standard static characterisation techniques, such as acid neutralisation capacity (ANC), maximum potential acidity, and associated acid-base accounting, require laboratory tests that can be difficult to obtain rapidly at remote mine sites. We show that a combination of paste pH and a simple portable carbonate dissolution test, both techniques that can be done in the field in a 15 min time-frame, is useful for distinguishing rocks that are potentially acid-forming from those that are acid-neutralising. Use of these techniques could allow characterisation of mine wastes at the metre scale during mine excavation operations. Our application of these techniques to pyrite-bearing (total S = 1-4 wt%) but variably calcareous coal mine overburden shows that there is a strong correlation between the portable carbonate dissolution technique and laboratory-determined ANC measurements (range of 0-10 wt% calcite equivalent). Paste pH measurements on the same rocks are bimodal, with high-sulphur, low-calcite rocks yielding pH near 3 after 10 min, whereas high-ANC rocks yield paste pH of 7-8. In our coal mine example, the field tests were most effective when used in conjunction with stratigraphy. However, the same field tests have potential for routine use in any mine in which distinction of acid-generating rocks from acid-neutralising rocks is required. Calibration of field-based acid-base accounting characteristics of the rocks with laboratory-based static and/or kinetic tests is still necessary.
Iván, Kristóf; Maráz, Anna
2015-12-20
Detection and identification of food-borne pathogenic bacteria are key points for the assurance of microbiological food safety. Traditional culture-based methods are more and more replaced by or supplemented with nucleic acid based molecular techniques, targeting specific (preferably virulence) genes in the genomes. Internationally validated DNA amplification - most frequently real-time polymerase chain reaction - methods are applied by the food microbiological testing laboratories for routine analysis, which will result not only in shortening the time for results but they also improve the performance characteristics (e.g. sensitivity, specificity) of the methods. Beside numerous advantages of the polymerase chain reaction based techniques for routine microbiological analysis certain drawbacks have to be mentioned, such as the high cost of the equipment and reagents, as well as the risk of contamination of the laboratory environment by the polymerase chain reaction amplicons, which require construction of an isolated laboratory system. Lab-on-a-chip systems can integrate most of these laboratory processes within a miniaturized device that delivers the same specificity and reliability as the standard protocols. The benefits of miniaturized devices are: simple - often automated - use, small overall size, portability, sterility due to single use possibility. These miniaturized rapid diagnostic tests are being researched and developed at the best research centers around the globe implementing various sample preparation and molecular DNA amplification methods on-chip. In parallel, the aim of the authors' research is to develop microfluidic Lab-on-a-chip devices for the detection and identification of food-borne pathogenic bacteria.
Kutsuna, Satoshi; Hayakawa, Kayoko; Kato, Yasuyuki; Fujiya, Yoshihiro; Mawatari, Momoko; Takeshita, Nozomi; Kanagawa, Shuzo; Ohmagari, Norio
2015-07-01
Without specific symptoms, diagnosis of febrile illness in returning travelers is challenging. Dengue, malaria, and enteric fever are common causes of fever in returning travelers and timely and appropriate treatment is important. However, differentiation is difficult without specific diagnostic tests. A retrospective study was conducted at the National Centre for Global Health and Medicine (NCGM) from April 2005 to March 2013. Febrile travelers returning from overseas who were diagnosed with dengue, malaria, or enteric fever were included in this study. Clinical characteristics and laboratory findings were compared for each diagnosis. During the study period, 86 malaria, 85 dengue, and 31 enteric fever cases were identified. The mean age of the study cohort was 33.1 ± 12 years and 134 (66.3%) study participants were male. Asia was the most common area visited by returning travelers with fevers (89% of dengue, 18.6% of malaria, and 100% of enteric fever cases), followed by Africa (1.2% of dengue and 70.9% of malaria cases). Clinical characteristics and laboratory findings were significantly different among each group with each diagnosis. Decision tree models revealed that returning from Africa and CRP levels < 10 mg/L were factors specific for diagnosis of malaria and dengue fever, respectively. Clinical manifestations, simple laboratory test results, and regions of travel are helpful to distinguish between dengue, malaria, and enteric fever in febrile returning travelers with non-specific symptoms.
Can simple tank changes benefit the welfare of laboratory zebrafish Danio rerio?
Lee, C J; Tyler, C R; Paull, G C
2018-03-01
This study examined the effects of simple changes in the tank environment on the wellbeing of laboratory-maintained zebrafish Danio rerio. Groups of D. rerio were either housed in stable environments (where they were maintained in the same tanks throughout the study) or in environments subject to change (where they were periodically moved to novel but identical tanks) and the effects of these treatments on morphometry, reproductive success and aggressive behaviour assessed. No effect of simple tank changes was found on body condition, reproductive output or aggression, for the periods of time studied, indicating that more complex scenarios in housing tank conditions are required for significant welfare benefits for captive D. rerio. © 2018 The Fisheries Society of the British Isles.
Playing evolution in the laboratory: From the first major evolutionary transition to global warming
NASA Astrophysics Data System (ADS)
Fragata, Inês; Simões, Pedro; Matos, Margarida; Szathmáry, Eörs; Santos, Mauro
2018-05-01
Experimental evolution allows testing hypotheses derived from theory or from observed patterns in nature. We have designed a droplet-based microfluidic “evolution machine” to test how transient compartmentalization (“trait-groups”) of independent molecular replicators (likely a critical step in the origin of life) could have prevented the spread of parasitic mutants; that is, inactive RNAs that have been reported to spoil a system of free replicators. In remarkable agreement with the theory, we show that this simple population structure was sufficient to prevent takeover by inactive RNAs. A more complex scenario arises when we use experimental evolution to test field-derived hypotheses; for instance, the idea that temperature is driving genetic spatiotemporal patterns of climate change. In the fly Drosophila subobscura, latitudinal clines in gene arrangement frequencies occur worldwide, and more equatorial gene arrangements are becoming more frequent at higher latitudes as a correlated response to climate change. However, the evolution at different constant temperatures in the laboratory was not consistent with patterns in nature, suggesting some limitations of experimental evolution. Finally, also in D. subobscura, we show that repeatability in experimental evolution is staggeringly consistent for life history traits, making evolution quite predictable and suggesting that laboratory selection can quickly erase differences between populations. Yet, the genetic paths used to attain the same adaptive phenotypes are complex and unpredictable. Contribution to the Focus Issue Evolutionary Modeling and Experimental Evolution edited by José Cuesta, Joachim Krug and Susanna Manrubia.
DOSE PROFILE MODELING OF IDAHO NATIONAL LABORATORY’S ACTIVE NEUTRON INTERROGATION TEST FACILITY
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. L. Chichester; E. H. Seabury; J. M. Zabriskie
2009-06-01
A new research and development laboratory has been commissioned at Idaho National Laboratory for performing active neutron interrogation research and development. The facility is designed to provide radiation shielding for DT fusion (14.1 MeV) neutron generators (2 x 108 neutrons per second), DD fusion (2.5 MeV) neutron generators (up to 2 x 106 neutrons per second), and 252Cf spontaneous fission neutron sources (6.7 x 107 neutrons per second, 30 micrograms). Shielding at the laboratory is comprised of modular concrete shield blocks 0.76 m thick with tongue-in-groove features to prevent radiation streaming, arranged into one small and one large test vault.more » The larger vault is designed to allow operation of the DT generator and has walls 3.8 m tall, an entrance maze, and a fully integrated electrical interlock system; the smaller test vault is designed for 252Cf and DD neutron sources and has walls 1.9 m tall and a simple entrance maze. Both analytical calculations and numerical simulations were used in the design process for the building to assess the performance of the shielding walls and to ensure external dose rates are within required facility limits. Dose rate contour plots have been generated for the facility to visualize the effectiveness of the shield wall and entrance maze and to illustrate the spatial profile of the radiation dose field above the facility and the effects of skyshine around the vaults.« less
Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen
2015-08-25
To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.
Singh, Manju; Singh, Shoor Vir; Gupta, Saurabh; Chaubey, Kundan Kumar; Stephan, Bjorn John; Sohal, Jagdip Singh; Dutta, Manali
2018-04-26
Early rapid detection of Mycobacterium avium subspecies paratuberculosis (MAP) bacilli in milk samples is the major challenge since traditional culture method is time consuming and laboratory dependent. We report a simple, sensitive and specific nano-technology based 'Nano-immuno test' capable of detecting viable MAP bacilli in the milk samples within 10 h. Viable MAP bacilli were captured by MAP specific antibody-conjugated magnetic nano-particles using resazurin dye as chromogen. Test was optimized using true culture positive (10-bovine and 12-goats) and true culture negative (16-bovine and 25-goats) raw milk samples. Domestic livestock species in India are endemically infected with MAP. After successful optimization, sensitivity and specificity of the 'nano-immuno test' in goats with respect to milk culture was 91.7% and 96.0%, respectively. Whereas, it was 90.0% (sensitivity) and 92.6% (specificity) with respect to IS900 PCR. In bovine milk samples, sensitivity and specificity of 'nano-immuno test' with respect to milk culture was 90.0% and 93.7%, respectively. However, with respect to IS900 PCR, the sensitivity and specificity was 88.9% and 94.1%, respectively. Test was validated with field raw milk samples (goats-258 and bovine-138) collected from domestic livestock species to detect live/viable MAP bacilli. Of 138 bovine raw milk samples screened by six diagnostic tests, 81 (58.7%) milk samples were positive for MAP infection in one or more than one diagnostic tests. Of 81 (58.7%) positive bovine raw milk samples, only 24 (17.4%) samples were detected positive for the presence of viable MAP bacilli. Of 258 goats raw milk samples screened by six diagnostic tests, 141 (54.6%) were positive for MAP infection in one or more than one test. Of 141 (54.6%) positive raw milk samples from goats, only 48 (34.0%) were detected positive for live MAP bacilli. Simplicity and efficiency of this novel 'nano-immuno test' makes it suitable for wide-scale screening of milk samples in the field. Standardization, validation and re-usability of functionalized nano-particles and the test was successfully achieved in field samples. Test was highly specific, simple to perform and easy to read by naked eyes and does not require laboratory support in the performance of test. Test has potential to be used as screening test to estimate bio-load of MAP in milk samples at National level.
Mirus, Benjamin B.; Perkins, Kim S.
2012-01-01
The bottomless bucket (BB) approach (Nimmo et al., 2009a) is a cost-effective method for rapidly characterizing field-saturated hydraulic conductivity Kfs of soils and alluvial deposits. This practical approach is of particular value for quantifying infiltration rates in remote areas with limited accessibility. A similar approach for bedrock outcrops is also of great value for improving quantitative understanding of infiltration and recharge in rugged terrain. We develop a simple modification to the BB method for application to bedrock outcrops, which uses a non-toxic, quick-drying silicone gel to seal the BB to the bedrock. These modifications to the field method require only minor changes to the analytical solution for calculating Kfs on soils. We investigate the reproducibility of the method with laboratory experiments on a previously studied calcarenite rock and conduct a sensitivity analysis to quantify uncertainty in our predictions. We apply the BB method on both bedrock and soil for sites on Pahute Mesa, which is located in a remote area of the Nevada National Security Site. The bedrock BB tests may require monitoring over several hours to days, depending on infiltration rates, which necessitates a cover to prevent evaporative losses. Our field and laboratory results compare well to Kfs values inferred from independent reports, which suggests the modified BB method can provide useful estimates and facilitate simple hypothesis testing. The ease with which the bedrock BB method can be deployed should facilitate more rapid in-situ data collection than is possible with alternative methods for quantitative characterization of infiltration into bedrock.
A practical workshop for generating simple DNA fingerprints of plants.
Rouzière, A-S; Redman, J E
2011-01-01
Gel electrophoresis DNA fingerprints offer a graphical and visually appealing illumination of the similarities and differences between DNA sequences of different species and individuals. A polymerase chain reaction (PCR) and restriction digest protocol was designed to give high-school students the opportunity to generate simple fingerprints of plants thereby illustrating concepts and techniques in genetics and molecular biology. Three combinations of primers/restriction enzyme targeting chloroplast DNA were sufficient to generate patterns that enabled visual discrimination of plant species. The protocol was tested with a range of common fruit, vegetable, and herb plants that could be easily cultivated and handled in the laboratory. Toxic or hazardous materials such as ethidium bromide and liquid nitrogen were avoided. The protocol was validated as a university outreach workshop targeted at a group of up to 10 high-school students. In a teaching laboratory, students sampled plants, setup the PCR reaction and restriction digest using microliter pipettes, and loaded the digested samples on an agarose gel. The workshop was structured as 2 × 2.5-hour sessions on separate days. The main challenges stemmed from the speed and accuracy of pipetting, especially at the gel loading stage. Feedback from students was largely positive, with the majority reporting that they had both enjoyed and learnt from the experience. Copyright © 2010 Wiley Periodicals, Inc.
Ickmans, Kelly; Meeus, Mira; De Kooning, Margot; De Backer, Annabelle; Kooremans, Daniëlle; Hubloue, Ives; Schmitz, Tom; Van Loo, Michel; Nijs, Jo
2016-02-01
Controlled laboratory study. In addition to persistent pain, people with chronic whiplash-associated disorders (WAD) commonly deal with cognitive dysfunctions. In healthy individuals, aerobic exercise has a positive effect on cognitive performance, and preliminary evidence in other chronic pain conditions reveals promising results as well. However, there is evidence that people with chronic WAD may show a worsening of the symptom complex following physical exertion. To examine postexercise cognitive performance in people with chronic WAD. People with chronic WAD (n = 27) and healthy, inactive, sex- and age-matched controls (n = 27) performed a single bout of an incremental submaximal cycling exercise. Before and after the exercise, participants completed 2 performance-based cognitive tests assessing selective and sustained attention, cognitive inhibition, and simple and choice reaction time. At baseline, people with chronic WAD displayed significantly lower scores on sustained attention and simple reaction time (P<.001), but not on selective attention, cognitive inhibition, and choice reaction time (P>.05), compared with healthy controls. Postexercise, both groups showed significantly improved selective attention and choice reaction time (chronic WAD, P = .001; control, P<.001), while simple reaction time significantly increased (P = .037) only in the control group. In both groups, no other significant changes in sustained attention, cognitive inhibition, pain, and fatigue were observed (P>.05). In the short term, postexercise cognitive functioning, pain, and fatigue were not aggravated in people with chronic WAD. However, randomized controlled trials are required to study the longer-term and isolated effects of exercise on cognitive functioning.
Wan Nor Amilah, W A W; Noor Izani, N J; Ng, W K; Ashraful Haq, J
2012-12-01
Clinical utilization of carbapenems remains under threat with the emergence of acquired carbapenemase-producing bacteria, particularly metallo-β-lactamases (MBL). Rapid detection of MBL-producing Gram-negative bacilli is essential to prevent their widespread dissemination. However, no standardized detection method is available for routine laboratory use. The purpose of the study was to evaluate a chelating-agent based double disk synergic test and disk potentiation test for MBL-producing strain detection and to determine the isolation rate of MBL-producing Pseudomonas aeruginosa and Acinetobacter from clinical samples in our tertiary teaching hospital. A total of 22 and 66 imipenem-resistant P. aeruginosa and Acinetobacter isolates respectively were tested with ceftazidime (CAZ) disk by modified double disk synergic test and disk potentiation test using ethylenediaminetetraacetic acid (EDTA) and 2-mercaptopropionic acid (as chelating agents) to detect MBL production. The tests were compared with EDTA-phenanthroline-imipenem (EPI) microdilution MIC test as gold standard. MBL positive strains were detected in 17 (77.3%) P. aeruginosa and 2 (3.5%) Acinetobacter isolates. The disk potentiation test with 2-mercaptopropionic acid (2-MPA) dilution of 1:12 provided the most acceptable sensitivities and specificities (88.2% sensitivity and 100% specificity in P. aeruginosa; 100% sensitivity and specificity in Acinetobacter) compared to other screening methods used in this study. This study provided useful information on the local prevalence of MBL-producing P. aeruginosa and Acinetobacter in our hospital. Disc potentiation test with CAZ/2-MPA disc appears to be reliable and convenient MBL detection method in the routine clinical laboratory.
Change in Soil Porosity under Load
NASA Astrophysics Data System (ADS)
Dyba, V. P.; Skibin, E. G.
2017-11-01
The theoretical basis for the process of soil compaction under various loading paths is considered in the article, the theoretical assumptions are compared with the results of the tests of clay soil on a stabilometer. The variant of the critical state model of the sealing plastic-rigid environment is also considered the strength characteristics of which depend on the porosity coefficient. The loading surface is determined by the results of compression and stabilometrical tests. In order to clarify the results of this task, it is necessary to carry out stabilometric tests under conditions of simple loading, i.e. where the vertical pressure would be proportional to the compression pressure σ3 = kσ1. Within the study the attempts were made to confirm the model given in the beginning of the article by laboratory tests. After the analysis of the results, the provided theoretical assumptions were confirmed.
Validation of the use of synthetic imagery for camouflage effectiveness assessment
NASA Astrophysics Data System (ADS)
Newman, Sarah; Gilmore, Marilyn A.; Moorhead, Ian R.; Filbee, David R.
2002-08-01
CAMEO-SIM was developed as a laboratory method to assess the effectiveness of aircraft camouflage schemes. It is a physically accurate synthetic image generator, rendering in any waveband between 0.4 and 14 microns. Camouflage schemes are assessed by displaying imagery to observers under controlled laboratory conditions or by analyzing the digital image and calculating the contrast statistics between the target and background. Code verification has taken place during development. However, validation of CAMEO-SIM is essential to ensure that the imagery produced is suitable to be used for camouflage effectiveness assessment. Real world characteristics are inherently variable, so exact pixel to pixel correlation is unnecessary. For camouflage effectiveness assessment it is more important to be confident that the comparative effects of different schemes are correct, but prediction of detection ranges is also desirable. Several different tests have been undertaken to validate CAMEO-SIM for the purpose of assessing camouflage effectiveness. Simple scenes have been modeled and measured. Thermal and visual properties of the synthetic and real scenes have been compared. This paper describes the validation tests and discusses the suitability of CAMEO-SIM for camouflage assessment.
Nia, Yacine; Rodriguez, Mélanie; Zeleny, Reinhard; Herbin, Sabine; Auvray, Frédéric; Fiebig, Uwe; Avondet, Marc-André; Munoz, Amalia; Hennekinne, Jacques-Antoine
2016-01-01
The aim of this work was to organize the first proficiency test (PT) dedicated to staphylococcal enterotoxin B (SEB) detection in milk and buffer solutions. This paper describes the organization of the PT trial according to EN ISO 17043 requirements. Characterization of the SEB stock solution was performed using SDS-PAGE and SE-specific ELISA, and amino acid analysis was used to assign its protein concentration. The solution was then used to prepare six PT materials (four milk and two buffer batches) at a ng/g toxin level, which included one blank and one SEA-containing milk as specificity control. Suitable material homogeneity and stability were assessed using screening and quantitative ELISAs. Among the methods used by the participants, ELISA-based methods demonstrated their efficiency for the detection of SEB in both simple and complex matrices. The results serve as a basis for further improving the detection capabilities in expert laboratories and can therefore be considered as a contribution to biopreparedness. PMID:27649244
Test of the Angle Detecting Inclined Sensor (ADIS) Technique for Measuring Space Radiation
NASA Astrophysics Data System (ADS)
Connell, J. J.; Lopate, C.; McLaughlin, K. R.
2009-12-01
In February 2008 we exposed an Angle Detecting Inclined Sensor (ADIS) prototype to beams of 150 MeV/u 78Kr and fragments at the National Superconducting Cyclotron Laboratory's (NSCL) Coupled Cyclotron Facility (CCF). ADIS is a highly innovative and uniquely simple detector configuration used to determine the angles of incidence of heavy ions in energetic charged particle instruments. Corrections for angle of incidence are required for good charge and mass separation. An ADIS instrument is under development to fly on the GOES-R series of weather satellites. The prototype tested consisted of three ADIS detectors, two of which were inclined at an angle to the telescope axis, forming the initial detectors in a five-detector telescope stack. By comparing the signals from the ADIS detectors, the angle of incidence may be determined and a pathlength correction applied to charge and mass determinations. Thus, ADIS replaces complex position sensing detectors with a system of simple, reliable and robust Si detectors. Accelerator data were taken at multiple angles to both primary and secondary beams with a spread of energies. This test instrument represents an improvement over the previous ADIS prototype in that it used oval inclined detectors and a much lower-mass support structure, thus reducing the number of events passing through dead material. These data show a charge peak resolution of 0.18 ± 0.01 e at Br (Z = 35), excellent for such a simple instrument. We will present the results of this test. The ADIS instrument development project was partially funded by NASA under the Living With a Star (LWS) Targeted Research and Technology program (grant NAG5-12493).
Time-integrated sampling of fluvial suspended sediment: a simple methodology for small catchments
NASA Astrophysics Data System (ADS)
Phillips, J. M.; Russell, M. A.; Walling, D. E.
2000-10-01
Fine-grained (<62·5 µm) suspended sediment transport is a key component of the geochemical flux in most fluvial systems. The highly episodic nature of suspended sediment transport imposes a significant constraint on the design of sampling strategies aimed at characterizing the biogeochemical properties of such sediment. A simple sediment sampler, utilizing ambient flow to induce sedimentation by settling, is described. The sampler can be deployed unattended in small streams to collect time-integrated suspended sediment samples. In laboratory tests involving chemically dispersed sediment, the sampler collected a maximum of 71% of the input sample mass. However, under natural conditions, the existence of composite particles or flocs can be expected to increase significantly the trapping efficiency. Field trials confirmed that the particle size composition and total carbon content of the sediment collected by the sampler were representative statistically of the ambient suspended sediment.
Development of Supersonic Combustion Experiments for CFD Modeling
NASA Technical Reports Server (NTRS)
Baurle, Robert; Bivolaru, Daniel; Tedder, Sarah; Danehy, Paul M.; Cutler, Andrew D.; Magnotti, Gaetano
2007-01-01
This paper describes the development of an experiment to acquire data for developing and validating computational fluid dynamics (CFD) models for turbulence in supersonic combusting flows. The intent is that the flow field would be simple yet relevant to flows within hypersonic air-breathing engine combustors undergoing testing in vitiated-air ground-testing facilities. Specifically, it describes development of laboratory-scale hardware to produce a supersonic combusting coaxial jet, discusses design calculations, operability and types of flames observed. These flames are studied using the dual-pump coherent anti- Stokes Raman spectroscopy (CARS) - interferometric Rayleigh scattering (IRS) technique. This technique simultaneously and instantaneously measures temperature, composition, and velocity in the flow, from which many of the important turbulence statistics can be found. Some preliminary CARS data are presented.
McMaster, Philip R. B.; Robertson, E. Arthur; Witebsky, Frank G.; MacLowry, James D.
1978-01-01
The MIC-2000 96-channel dispenser was evaluated for accuracy and repeatability of dispensing 50-μl volumes of water. It was found to perform within the manufacturer's specifications for accuracy of ±5%, but not within the limits for repeatability of ±1%. Overall, instrument performance was found to be satisfactory for the antimicrobial susceptibility testing technique which has been implemented in this laboratory. A method is suggested for simple evaluation of the volumes dispensed. A variety of antibiotics may be stored in Trypticase soy broth in Microtiter plates without loss of potency for periods of at least 2 weeks at −20°C and 4 months at −70°C. PMID:666304
An Inexpensive Robotics Laboratory.
ERIC Educational Resources Information Center
Inigo, R. M.; Angulo, J. M.
1985-01-01
Describes the design and implementation of a simple robot manipulator. The manipulator has three degrees of freedom and is controlled by a general purpose microcomputer. The basis for the manipulator (which costs under $100) is a simple working model of a crane. (Author/JN)
Siddiqui, Mohd Farhan; Kim, Soocheol; Jeon, Hyoil; Kim, Taeho; Joo, Chulmin; Park, Seungkyung
2018-03-04
Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III) in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample) and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.
NASA Astrophysics Data System (ADS)
Lammen, Yannick; Reinacher, Andreas; Brewster, Rick; Greiner, Benjamin; Graf, Friederike; Krabbe, Alfred
2016-07-01
The Stratospheric Observatory For Infrared Astronomy (SOFIA) reached its full operational capability in 2014 and takes off from the NASA Armstrong Flight Research Center to explore the universe about three times a week. Maximizing the program's scientific output naturally leaves very little flight time for implementation and test of improved soft- and hardware. Consequently, it is very important to have a comparable test environment and infrastructure to perform troubleshooting, verifications and improvements on ground without interfering with science missions. SOFIA's Secondary Mirror Mechanism is one of the most complex systems of the observatory. In 2012 a first simple laboratory mockup of the mechanism was built to perform basic controller tests in the lower frequency band of up to 50Hz. This was a first step to relocate required engineering tests from the active observatory into the laboratory. However, to test and include accurate filters and damping methods as well as to evaluate hardware modifications a more precise mockup is required that represents the system characteristics over a much larger frequency range. Therefore the mockup has been improved in several steps to a full test environment representing the system dynamics with high accuracy. This new ground equipment allows moving almost the entire secondary mirror test activities away from the observatory. As fast actuator in the optical path, the SMM also plays a major role in SOFIA's pointing stabilization concept. To increase the steering bandwidth, hardware changes are required that ultimately need to be evaluated using the telescope optics. One interesting concept presented in this contribution is the in- stallation of piezo stack actuators between the mirror and the chopping mechanism. First successful baseline tests are presented. An outlook is given about upcoming performance tests of the actively controlled piezo stage with local metrology and optical feedback. To minimize the impact on science time, the laboratory test setup will be expanded with an optical measurement system so that it can be used for the vast majority of testing.
Gürtler, R E; Oneto, M L; Cecere, M C; Castañera, M B; Canale, D M
2001-03-01
We successfully applied the phenolphthalin (Kastle-Meyer) test used in forensic chemistry to distinguish between feces from triatomines and other domestic arthropods in sensing devices used for vector surveillance. All black or dark brown, but not white or yellow, fecal smears from laboratory-reared or field-collected Triatoma infestans Klug, Triatoma guasayana Wydgozinsky & Abalos, Triatoma sordida Ståhl (recently revalidated as Triatoma garciabesi Carcavallo, Cichero, Martínez, Prosen & Ronderos) tested positive, whereas dejecta from cockroaches and spiders, crickets, beetles, predatory bugs, and domestic flies tested negative. Black or dark brown dejecta from female Aedes aegypti L. and Cimex lectularius L. bedbugs also tested positive. In sellsing devices installed in bedrooms of 11 houses in Amamá, rural northwestern Argentina, where neither cimicid bedbugs nor argasid ticks had been found over the years, only 62% of the black or dark brown fecal smears attributed to triatomines by a skilled observer tested phenolphthalin-positive. After insecticidal spraying, when bedroom areas were not colonized by triatomines, only 33-40% of the black or dark brown fecal smears in sensor boxes attributed to triatomines by another skilled observer tested phenolphthalin-positive. Eleven (79%) ofthe 14 houses with dubious or nontypical triatomine feces tested phenolphthalin-positive at least once during 1993-1995. Our study introduces a low-cost, simple and effective procedure for the identification of triatomine feces. The test, as a helpful adjunct to sensing devices used in triatomine surveillance, will aid in the accurate detection of infestations and the determination of the need for insecticide application.
A Simple Lab Exercise Demonstrating Koch's Postulates.
ERIC Educational Resources Information Center
Fulton, Michael M.
1981-01-01
Describes a laboratory exercise which applies Koch's Postulates to a plant disease, bacterial speck. Includes an explanation of Koch's Postulate, list of equipment needed, advance preparation, outline of the three-week activity, and variations of the laboratory exercise. (DS)
DO TIE LABORATORY BASED METHODS REALLY REFLECT FIELD CONDITIONS
Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both interstitial waters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question ...
The Effect of Slipstream Obstructions on Air Propellers
NASA Technical Reports Server (NTRS)
Lesley, E P; Woods, B M
1924-01-01
The screw propeller on airplanes is usually placed near other objects, and hence its performance may be modified by them. Results of tests on propellers free from slip stream obstructions, both fore and aft, are therefore subject to correction, for the effect of such obstructions and the purpose of the investigation was to determine the effect upon the thrust and torque coefficients and efficiency, for previously tested air propellers, of obstructions placed in the slip stream, it being realized that such previous tests had been conducted under somewhat ideal conditions that are impracticable of realization in flight. Simple geometrical forms were used for the initial investigation. Such forms offered the advantage of easy, exact reproduction at another time or in other laboratories, and it was believed that the effects of obstructions usually encountered might be deduced or surmise from those chosen.
Fully optimized shaped pupils: preparation for a test at the Subaru Telescope
NASA Astrophysics Data System (ADS)
Carlotti, Alexis; Kasdin, N. Jeremy; Martinache, Frantz; Vanderbei, Robert J.; Young, Elizabeth J.; Che, George; Groff, Tyler D.; Guyon, Olivier
2012-09-01
The SCExAO instrument at the Subaru telescope, mainly based on a PIAA coronagraph can benefit from the addition of a robust and simple shaped pupil coronagraph. New shaped pupils, fully optimized in 2 dimensions, make it possible to design optimal apodizers for arbitrarily complex apertures, for instance on-axis telescopes such as the Subaru telescope. We have designed several masks with inner working angles as small as 2.5 λ / D, and for high-contrast regions with different shapes. Using Princeton University nanofabrication facilities, we have manufactured two masks by photolithography. These masks have been tested in the laboratory, both in Princeton and in the facilities of the National Astronomical Observatory of Japan (NAOJ) in Hilo. The goal of this work is to prepare tests on the sky of a shaped pupil coronagraph in 2012.
Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L
2018-01-01
Aims A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R2), using R2 as the primary metric of assay agreement. However, the use of R2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. Methods We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Results Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. Conclusions The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. PMID:28747393
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luna, R. E.
This paper provides a simple model for estimating the release of respirable aerosols resulting from an attack on a spent fuel cask using a high energy density device (HEDD). Two primary experiments have provided data on potential releases from spent fuel casks under HEDD attack. Sandia National Laboratories (SNL) conducted the first in the early 1980's and the second was sponsored by Gessellshaft fur Anlagen- and Reaktorsicherheit (GRS) in Germany and conducted in France in 1994. Both used surrogate spent fuel assemblies in real casks. The SNL experiments used un-pressurized fuel pin assemblies in a single element cask while themore » GRS tests used pressurized fuel pin assemblies in a 9-element cask. Data from the two test programs is reasonably consistent, given the differences in the experiments, but the use of the test data for prediction of releases resulting from HEDD attack requires a method for accounting for the effects of pin pressurization release and the ratio of pin plenum gas release to cask free volume (VR). To account for the effects of VR and to link the two data sources, a simple model has been developed that uses both the SNL data and the GRS data as well as recent test data on aerosols produced in experiments with single pellets subjected to HEDD effects conducted under the aegis of the International Consortium's Working Group on Sabotage of Transport and Storage Casks (WGSTSC). (authors)« less
DO TIE LABORATORY BASED ASSESSMENT METHODS REALLY PREDICT FIELD EFFECTS?
Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both porewaters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question of whethe...
Measuring the Transition Temperature of a Superconductor in a Pre-University Laboratory
ERIC Educational Resources Information Center
Ireson, Gren
2006-01-01
This article presents the methodology and results for a simple approach to the measurement of the transition temperature of a superconducting material, in a pre-university laboratory session, using readily available apparatus (and some liquid nitrogen).
ERIC Educational Resources Information Center
Nicklin, R. C.
1985-01-01
Microcomputers can record laboratory measurements which human laboratory partners can never collect. Simple, harder, and general-purpose interfaces are discussed, with suggestions for several experiments involving an exercise bike, acceleration, and pendulums. Additional applications with pH meters, spectrophotometers, and chromatographs are also…
The Gabriel Synthesis of Benzylamine
ERIC Educational Resources Information Center
Nigh, W. G.
1975-01-01
Describes an undergraduate organic chemistry laboratory experiment which utilizes the Gabriel Synthesis to demonstrate the acidity of imides and to provide an example of nucleophilic substitution reactions. The experiment also demonstrates the laboratory techniques involved in simple and steam distillation, filtration, extraction, and…
SOBA: sequence ontology bioinformatics analysis.
Moore, Barry; Fan, Guozhen; Eilbeck, Karen
2010-07-01
The advent of cheaper, faster sequencing technologies has pushed the task of sequence annotation from the exclusive domain of large-scale multi-national sequencing projects to that of research laboratories and small consortia. The bioinformatics burden placed on these laboratories, some with very little programming experience can be daunting. Fortunately, there exist software libraries and pipelines designed with these groups in mind, to ease the transition from an assembled genome to an annotated and accessible genome resource. We have developed the Sequence Ontology Bioinformatics Analysis (SOBA) tool to provide a simple statistical and graphical summary of an annotated genome. We envisage its use during annotation jamborees, genome comparison and for use by developers for rapid feedback during annotation software development and testing. SOBA also provides annotation consistency feedback to ensure correct use of terminology within annotations, and guides users to add new terms to the Sequence Ontology when required. SOBA is available at http://www.sequenceontology.org/cgi-bin/soba.cgi.
Robertson, W M; Parker, J M
2012-03-01
A straightforward and inexpensive implementation of acoustic impulse response measurement is described utilizing the signal processing technique of coherent averaging. The technique is capable of high signal-to-noise measurements with personal computer data acquisition equipment, an amplifier/speaker, and a high quality microphone. When coupled with simple waveguide test systems fabricated from commercial PVC plumbing pipe, impulse response measurement has proven to be ideal for undergraduate research projects-often of publishable quality-or for advanced laboratory experiments. The technique provides important learning objectives for science or engineering students in areas such as interfacing and computer control of experiments; analog-to-digital conversion and sampling; time and frequency analysis using Fourier transforms; signal processing; and insight into a variety of current research areas such as acoustic bandgap materials, acoustic metamaterials, and fast and slow wave manipulation. © 2012 Acoustical Society of America
Shannon, Kyle M.; Gage, Gregory J.; Jankovic, Aleksandra; Wilson, W. Jeffrey
2014-01-01
The earthworm is ideal for studying action potential conduction velocity in a classroom setting, as its simple linear anatomy allows easy axon length measurements and the worm's sparse coding allows single action potentials to be easily identified. The earthworm has two giant fiber systems (lateral and medial) with different conduction velocities that can be easily measured by manipulating electrode placement and the tactile stimulus. Here, we present a portable and robust experimental setup that allows students to perform conduction velocity measurements within a 30-min to 1-h laboratory session. Our improvement over this well-known preparation is the combination of behaviorally relevant tactile stimuli (avoiding electrical stimulation) with the invention of minimal, low-cost, and portable equipment. We tested these experiments during workshops in both a high school and college classroom environment and found positive learning outcomes when we compared pre- and posttests taken by the students. PMID:24585472
AIR SCORE ASSESSMENT FOR ACUTE APPENDICITIS
VON-MÜHLEN, Bruno; FRANZON, Orli; BEDUSCHI, Murilo Gamba; KRUEL, Nicolau; LUPSELO, Daniel
2015-01-01
Background: Acute appendicitis is the most common cause of acute abdomen. Approximately 7% of the population will be affected by this condition during full life. The development of AIR score may contribute to diagnosis associating easy clinical criteria and two simple laboratory tests. Aim: To evaluate the score AIR (Appendicitis Inflammatory Response score) as a tool for the diagnosis and prediction of severity of acute appendicitis. Method: Were evaluated all patients undergoing surgical appendectomy. From 273 patients, 126 were excluded due to exclusion criteria. All patients were submitted o AIR score. Results: The value of the C-reactive protein and the percentage of leukocytes segmented blood count showed a direct relationship with the phase of acute appendicitis. Conclusion: As for the laboratory criteria, serum C-reactive protein and assessment of the percentage of the polymorphonuclear leukocytes count were important to diagnosis and disease stratification. PMID:26537139
Oscillations in a half-empty bottle
NASA Astrophysics Data System (ADS)
Bourges, Andréane; Chardac, Amélie; Caussarieu, Aude; Plihon, Nicolas; Taberlet, Nicolas
2018-02-01
When a half-empty bottle of water is pushed to roll on a flat surface, the oscillations of the fluid inside the bottle induce an overall jerky motion. These velocity fluctuations of the bottle are studied through simple laboratory experiments accessible to undergraduate students and can help them to grasp fundamental concepts in mechanics and hydrodynamics. We first demonstrate through an astute experiment that the rotation of the fluid and the bottle is decoupled. The equations of motion are then derived using a mechanical approach, while the hydrodynamics of the fluid motion is explained. Finally, the theory is tested against two benchmark experiments.
NASA Astrophysics Data System (ADS)
Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed
2016-04-01
Three simple, specific, accurate and precise spectrophotometric methods were developed for the determination of cefprozil (CZ) in the presence of its alkaline induced degradation product (DCZ). The first method was the bivariate method, while the two other multivariate methods were partial least squares (PLS) and spectral residual augmented classical least squares (SRACLS). The multivariate methods were applied with and without variable selection procedure (genetic algorithm GA). These methods were tested by analyzing laboratory prepared mixtures of the above drug with its alkaline induced degradation product and they were applied to its commercial pharmaceutical products.
NASA Astrophysics Data System (ADS)
Ibrahim, Maha M.; Elzanfaly, Eman S.; El-Zeiny, Mohamed B.; Ramadan, Nesreen K.; Kelani, Khadiga M.
2017-05-01
In this paper, three rapid, simple, accurate and precise spectrophotometric methods were developed for the determination of meclizine hydrochloride in the presence of pyridoxine hydrochloride without previous separation. The methods under study are dual wavelength (DWL), ratio difference (RD) and continuous wavelet transform (CWT). On the other hand, pyridoxine hydrochloride (PYH) was determined directly at 291 nm. The methods obey Beer's law in the range of (5-50 μg/mL) for both compounds. All the methods were validated according to the ICH guidelines where the accuracy was found to be 98.29, 99.59, 100.42 and 100.62% for DWL, RD, CWT and PYH; respectively. Moreover the precision of the methods were calculated in terms of %RSD and it was found to be 0.545, 0.372, 1.287 and 0.759 for DWL, RD,CWT and PYH; respectively. The selectivity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. So, they can be used for the routine analysis of pyridoxine hydrochloride and meclizine hydrochloride in quality-control laboratories.
The Hole-Count Test Revisited: Effects of Test Specimen Thickness
NASA Technical Reports Server (NTRS)
Lyman, C. E.; Ackland, D. W.; Williams, D. B.; Goldstein, J. I.
1989-01-01
For historical reasons the hole count, an important performance test for the Analytical Electron Microscope (AEM), is somewhat arbitrary yielding different numbers for different investigators. This was not a problem a decade ago when AEM specimens were often bathed with large fluxes of stray electrons and hard x rays. At that time the presence or absence of a thick Pt second condenser (C2) aperture could be detected by a simple comparison of the x-ray spectrum taken 'somewhere in the hole' with a spectrum collected on a 'typical thickness' of Mo or Ag foil. A high hole count of about 10-20% indicated that the electron column needed modifications; whereas a hole count of 1-2% was accepted for most AEM work. The absolute level of the hole count is a function of test specimen atomic number, overall specimen shape, and thin-foil thickness. In order that equivalent results may be obtained for any AEM in any laboratory in the world, this test must become standardized. The hole-count test we seek must be as simpl and as nonsubjective as the graphite 0.344nm lattice-line-resolution test. This lattice-resolution test spurred manufacturers to improve the image resolution of the TEM significantly in the 1970s and led to the even more stringent resolution tests of today. A similar phenomenon for AEM instruments would be welcome. The hole-count test can also indicate whether the spurious x-ray signal is generated by high-energy continuum x rays (bremsstrahlung) generated in the electron column (high K-line to L-line ratio) or uncollimated electrons passing through or around the C2 aperture (low K/L ratio).
Teaching Population Growth Using Cultures of Vinegar Eels, "Turbatrix aceti" (Nematoda)
ERIC Educational Resources Information Center
Wallace, Robert L.
2005-01-01
A simple laboratory exercise is presented that follows the population growth of the common vinegar eel, "Turbatrix aceti" (Nematoda), in a microcosm using a simple culture medium. It lends itself to an exercise in a single semester course. (Contains 4 figures.)
Mechanical Resonance of a Plastic Strip.
ERIC Educational Resources Information Center
Ayers, R. Dean
1981-01-01
Presents an experiment to illustrate mechanical resonance designed for use in lower division laboratories. The apparatus and procedure have been kept simple. The basic experiment yields measurements of amplitude versus driving frequency, but a fairly simple elaboration allows for measurements of phase lag as well. (Author/SK)
Understanding Exponential Growth: As Simple as a Drop in a Bucket.
ERIC Educational Resources Information Center
Goldberg, Fred; Shuman, James
1984-01-01
Provides procedures for a simple laboratory activity on exponential growth and its characteristic doubling time. The equipment needed consists of a large plastic bucket, an eyedropper, a stopwatch, an assortment of containers and graduated cylinders, and a supply of water. (JN)
Krepel, J; Patel, J; Sproston, A; Hopkins, F; Jang, D; Mahony, J; Chernesky, M
1999-10-01
Nucleic acid amplification testing is the most accurate approach to diagnosing Chlamydia trachomatis infections. Our objective was to compare the accuracy and cost savings of pooling urines as opposed to individual testing. Strategies of pooling urine specimens into groups of four (4x pool) or eight (8x pool) followed by testing the positive pools individually were compared to individual specimen testing to determine if significant cost savingS could be realized without compromising the sensitivity and specificity of the LCx C. trachomatis Assay (Abbott Laboratories, Abbott Park, Chicago, IL) performed in a busy private medical laboratory. A total of 1,220 patient urine samples, 1,187 male (97%) and 33 female (3%), were tested using the normal LCx specimen to cutoff ratio (S/CO) of 1.0 and a decreased S/CO value of 0.2. Individual testing identified 98.2% (109/111) of positive urines. The 4x pooling maneuver identified 92.8% (103/111) of positive patients with the regular cutoff and 96.4% (107/111) when the cutoff was decreased. These values were 95.9% (47/49) and 97.9% (48/49), respectively, when eight urines were pooled. Both pooling and individual testing strategies identified all the negative samples accurately. Cost savings of pooling were calculated to be 44.5% for pools of four and 37.5% for pools of eight, applying the lowered cutoff. Pooling urine specimens for testing with the C. trachomatis LCx system is a simple, accurate, and cost-saving approach that can significantly reduce the cost of amplified nucleic acid testing with minimal sacrifice of testing accuracy.
An Experiment Using Sucrose Density Gradients in the Undergraduate Biochemistry Laboratory.
ERIC Educational Resources Information Center
Turchi, Sandra L.; Weiss, Monica
1988-01-01
Describes an experiment to be performed in an undergraduate biochemistry laboratory that is based on a gradient centrifugation system employing a simple bench top centrifuge, a freezer, and frozen surcose gradient solution to separate macromolecules and subcellular components. (CW)
Sediment Toxicity Identification and Evaluation (TIE) methods have been developed for both interstitial waters and whole sediments. These relatively simple laboratory methods are designed to identify specific toxicants or classes of toxicants in sediments; however, the question ...
AG Dra -- a high density plasma laboratory
NASA Astrophysics Data System (ADS)
Young, Peter
2002-07-01
A STIS observation of the symbiotic star AG Draconis yielding spectra in the range 1150--10 000 Angstrom is requested. AG Dra is a non-eclipsing binary that shows strong, narrow nebular emission lines that originate in the wind of a K giant, photoionized by a hot white dwarf. The density of the nebula is around 10^10 electrons/cm^3 and is the perfect laboratory for testing the plasma modeling codes cloudy and xstar at high densities. These codes are used for a wide range of astrophysical objects including stellar winds, accretion disks, active galactic nuclei and Seyfert galaxies, and calibrating them against high signal-to-noise spectra from comparatively simple systems is essential. AG Dra is the perfect high density laboratory for this work. In addition, many previously undetected emission lines will be found through the high sensitivity of STIS, which will allow new plasma diagnostics to be tested. These twin objectives are particularly pertinent as the high sensitivity of emphHST/COS will will permit similar high resolution spectroscopy to be applied to a whole new regime of extragalactic objects. By combining far-UV data from Ause with complementary data from STIS, we will determine ratios of emission lines from the same ion, or ions of similar ionization level. These will permit a more complete set of diagnostics than are obtainable from one instrument alone.
WH Craib: a critical account of his work
Naidoo, DP
2009-01-01
Summary Summary One hundred years after its introduction, the ECG remains the most commonly used cardiovascular laboratory procedure. It fulfils all the requirements of a diagnostic test: it is non-invasive, simple to record, highly reproducible and can be applied serially. It is the first laboratory test to be performed in a patient with chest pain, syncope or cardiac arrhythmias. It is also a prognostic tool that aids in risk stratification and clinical management. Among the many South Africans who have made remarkable contributions in the field of electrocardiography, Don Craib was the first to investigate the changing patterns of the ECG action potential in isolated skeletal muscle strips under varying conditions. It was during his stay at Johns Hopkins Hospital in Baltimore and Sir Thomas Lewis laboratory in London that Craib made singular observations about the fundamental origins of electrical signals in the skeletal muscle, and from these developed his hypothesis on the generation of the action potential in the electrocardiogram. His proposals went contrary to scientific opinion at the time and he was rebuffed by the scientific community. Frank Wilson subsequently went on to develop Craib’s doublet hypothesis into the dipole theory, acknowledging Craib’s work. Today the dipole theory is fundamental to the understanding of the spread of electrical activation in the myocardium and the genesis of the action potential. PMID:19287808
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Austin; Chakraborty, Sudipta; Wang, Dexin
This paper presents a cyber-physical testbed, developed to investigate the complex interactions between emerging microgrid technologies such as grid-interactive power sources, control systems, and a wide variety of communication platforms and bandwidths. The cyber-physical testbed consists of three major components for testing and validation: real time models of a distribution feeder model with microgrid assets that are integrated into the National Renewable Energy Laboratory's (NREL) power hardware-in-the-loop (PHIL) platform; real-time capable network-simulator-in-the-loop (NSIL) models; and physical hardware including inverters and a simple system controller. Several load profiles and microgrid configurations were tested to examine the effect on system performance withmore » increasing channel delays and router processing delays in the network simulator. Testing demonstrated that the controller's ability to maintain a target grid import power band was severely diminished with increasing network delays and laid the foundation for future testing of more complex cyber-physical systems.« less
Evaluation of monoclonal antibody-based direct, rapid immunohistochemical test for rabies diagnosis.
Feng, Ye; Wang, Muyang; Liu, Tingfang; Zhang, Yan; Tu, Zhongzhong; Guo, Huancheng; Zhang, Cuijuan; Zhu, Renying; Ren, Wenlin; Sun, Le; Xu, Weidi; Wang, Yuyang; Li, Maohua; Tu, Changchun
2018-06-01
Rabies is a major public health problem in developing countries in Asia and Africa. Although a number of laboratory diagnoses can be used for rabies control, the WHO and OIE recommended gold standard for rabies diagnosis is the direct fluorescent antibody test (FAT). However, FAT is not widely used in developing countries because of deficient financial sources to procure fluorescent microscope. Recently the direct rapid immunohistochemical test (dRIT) has been developed and has a worldwide promising application, particularly in developing countries, since its result can be read by inexpensive light microscopy, in addition to be consistent with that of FAT. However, no commercial conjugated antibody is available to meet the laboratory demand. We describe here the production of a monoclonal antibody (MAb) against rabies virus (RABV) N protein and its use as a biotinylated conjugate in a dRIT. Tested against a batch of 107 brain specimens representing a wide phylogenetic diversity of RABV collected from different animal species with multiple geographical origins in China, results showed that the dRIT had 100% specificity (95% CI 0.93-1.00) and 96.49% sensitivity (95% CI 0.88-1.00) as compared with the gold standard FAT. It therefore provides a simple, economical alternative to FAT, particularly for use in rabies diagnosis in developing countries. Copyright © 2018 Elsevier B.V. All rights reserved.
Determination of total procyanidins in selected chocolate and confectionery products using DMAC.
Payne, Mark J; Hurst, William Jeffrey; Stuart, David A; Ou, Boxin; Fan, Ellen; Ji, Hongping; Kou, Yan
2010-01-01
A simple, specific, high-throughput colorimetric method based on the reaction of 4-dimethylaminocinnamaldehyde (DMAC) with flavan-3-ols was developed to determine total procyanidins in selected cacao-based products. Extracts of defatted samples were dispensed into a 96-well plate and reacted with DMAC. The absorbance of the reaction products was measured at 640 nm and compared to commercially available procyanidin B2 as a standard. The use of the 96-well plates and a plate reader dramatically improved sample throughput. A standard protocol was established and used for further studies. The calibration was found to be linear from 1-100 ppm. The DMAC reagent reacted relatively specifically to (-)-epicatechin, (+)-catechin, epigallocatechin, gallocatechin, the gallates of catechin, epicatechin, gallocatechin, and epigallocatechin, oligomeric procyanidins of cocoa up to n=4, and A-type procyanidins. Little or no reaction occurred with cyanidins and representative compounds of phenolic acids, flavones, flavanones, flavonols, anthocyanidins, isoflavones, and stilbenes. Sample precision studies were carried out on 10 different test materials over several weeks, and yielded RSD values of 4.0 to 9.5%. The method was ring-tested in three laboratories using blinded test materials including cocoa beans, cocoa powder, chocolate liquor, dark chocolate, and milk chocolate. There was excellent agreement of the results between laboratories.
Kutsuna, Satoshi; Hayakawa, Kayoko; Kato, Yasuyuki; Fujiya, Yoshihiro; Mawatari, Momoko; Takeshita, Nozomi; Kanagawa, Shuzo; Ohmagari, Norio
2015-04-01
Without specific symptoms, diagnosis of febrile illness in returning travelers is challenging. Dengue, malaria, and enteric fever are common causes of fever in returning travelers and timely and appropriate treatment is important. However, differentiation is difficult without specific diagnostic tests. A retrospective study was conducted at the National Centre for Global Health and Medicine (NCGM) from April 2005 to March 2013. Febrile travelers returning from overseas who were diagnosed with dengue, malaria, or enteric fever were included in this study. Clinical characteristics and laboratory findings were compared for each diagnosis. During the study period, 86 malaria, 85 dengue, and 31 enteric fever cases were identified. The mean age of the study cohort was 33.1 ± 12 years and 134 (66.3%) study participants were male. Asia was the most common area visited by returning travelers with fevers (89% of dengue, 18.6% of malaria, and 100% of enteric fever cases), followed by Africa (1.2% of dengue and 70.9% of malaria cases). Clinical characteristics and laboratory findings were significantly different among each group with each diagnosis. Decision tree models revealed that returning from Africa and CRP levels <10 mg/L were factors specific for diagnosis of malaria and dengue fever, respectively. Clinical manifestations, simple laboratory test results, and regions of travel are helpful to distinguish between dengue, malaria, and enteric fever in febrile returning travelers with non-specific symptoms. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Metrology of Large Parts. Chapter 5
NASA Technical Reports Server (NTRS)
Stahl, H. Philip
2012-01-01
As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.
Simple Demonstration of the Seebeck Effect
ERIC Educational Resources Information Center
Molki, Arman
2010-01-01
In this article we propose a simple and low-cost experimental set-up through which science educators can demonstrate the Seebeck effect using a thermocouple and an instrumentation amplifier. The experiment can be set up and conducted during a 1-hour laboratory session. (Contains 3 tables and 3 figures.)
Experimental Control of Simple Pendulum Model
ERIC Educational Resources Information Center
Medina, C.
2004-01-01
This paper conveys information about a Physics laboratory experiment for students with some theoretical knowledge about oscillatory motion. Students construct a simple pendulum that behaves as an ideal one, and analyze model assumption incidence on its period. The following aspects are quantitatively analyzed: vanishing friction, small amplitude,…
Jacks--A Study of Simple Machines.
ERIC Educational Resources Information Center
Parsons, Ralph
This vocational physics individualized student instructional module on jacks (simple machines used to lift heavy objects) contains student prerequisites and objectives, an introduction, and sections on the ratchet bumper jack, the hydraulic jack, the screw jack, and load limitations. Designed with a laboratory orientation, each section consists of…
A Progression of Static Equilibrium Laboratory Exercises
ERIC Educational Resources Information Center
Kutzner, Mickey; Kutzner, Andrew
2013-01-01
Although simple architectural structures like bridges, catwalks, cantilevers, and Stonehenge have been integral in human societies for millennia, as have levers and other simple tools, modern students of introductory physics continue to grapple with Newton's conditions for static equilibrium. As formulated in typical introductory physics…
Voltammetry at the Thin-Film Mercury Electrode (TFME).
ERIC Educational Resources Information Center
Pomeroy, R. S.; And Others
1989-01-01
Reviewed is the use of the Thin-Film Mercury Electrode for anodic stripping voltammetry, simple voltammetry of solution cations and cathodic stripping voltammetry for the determination of an environmentally important molecule, thiourea. The construction of a simple potentiostat and applications for student laboratory courses are included. (CW)
A Novel Mobile Testing Equipment for Rock Cuttability Assessment: Vertical Rock Cutting Rig (VRCR)
NASA Astrophysics Data System (ADS)
Yasar, Serdar; Yilmaz, Ali Osman
2017-04-01
In this study, a new mobile rock cutting testing apparatus was designed and produced for rock cuttability assessment called vertical rock cutting rig (VRCR) which was designed specially to fit into hydraulic press testing equipment which are available in almost every rock mechanics laboratory. Rock cutting trials were initiated just after the production of VRCR along with calibration of the measuring load cell with an external load cell to validate the recorded force data. Then, controlled rock cutting tests with both relieved and unrelieved cutting modes were implemented on five different volcanic rock samples with a standard simple-shaped wedge tool. Additionally, core cutting test which is an important approach for roadheader performance prediction was simulated with VRCR. Mini disc cutters and point attack tools were used for execution of experimental trials. Results clearly showed that rock cutting tests were successfully realized and measuring system is delicate to rock strength, cutting depth and other variables. Core cutting test was successfully simulated, and it was also shown that rock cutting tests with mini disc cutters and point attack tools are also successful with VRCR.
Issues Related to Large Flight Hardware Acoustic Qualification Testing
NASA Technical Reports Server (NTRS)
Kolaini, Ali R.; Perry, Douglas C.; Kern, Dennis L.
2011-01-01
The characteristics of acoustical testing volumes generated by reverberant chambers or a circle of loudspeakers with and without large flight hardware within the testing volume are significantly different. The parameters attributing to these differences are normally not accounted for through analysis or acoustic tests prior to the qualification testing without the test hardware present. In most cases the control microphones are kept at least 2-ft away from hardware surfaces, chamber walls, and speaker surfaces to minimize the impact of the hardware in controlling the sound field. However, the acoustic absorption and radiation of sound by hardware surfaces may significantly alter the sound pressure field controlled within the chamber/speaker volume to a given specification. These parameters often result in an acoustic field that may provide under/over testing scenarios for flight hardware. In this paper the acoustic absorption by hardware surfaces will be discussed in some detail. A simple model is provided to account for some of the observations made from Mars Science Laboratory spacecraft that recently underwent acoustic qualification tests in a reverberant chamber.
Hue discrimination in Iberoamerican Observers
NASA Astrophysics Data System (ADS)
Carranza, Jazmín; Medina, Juana
2008-04-01
In this work we analyze the Farnsworth Munsell 100 Hue Test results, this test offers a simple method for testing color discrimination and was applied to a sample of 129 observers, with natural daylight in the same conditions (the observers were men and women), all of these were participants in colorimetric training courses, and aged 20 to 76, with two to twenty five years experience in the color control manufacturer laboratories (of plastics, rugs, dyes, textiles, and paints). Their job titles included mixers, inspectors, shaders, matchers, passers, and dyers. The test was applied twice and the results here presented are the comparison between both tests, taking into account errors by mistakes incidence in each hue position, as well as the redeeming of each participant in both test. The comparison shows us that most of the mistakes are in the green hue in both tests, but in the second test, approximately 20 percent of the observers reduced those. Also we can to separate persons with normal color vision of those which have zones of color confusion. In this work it is show some ones results of the comparison between men and women.
Simple Experiments in Psychology.
ERIC Educational Resources Information Center
Ray, Wilbert S.
This material, developed for use in secondary schools, is a programmed-type learning package consisting of an "Instructor's Manual", a "Student's Introduction", and a "Laboratory Manual". The general goal of the program is to teach students to distinguish between reliable and unreliable information. The "Laboratory Manual" contains nine simple…
Teaching Chromatography Using Virtual Laboratory Exercises
ERIC Educational Resources Information Center
Stone, David C.
2007-01-01
Though deceptively simple to teach, chromatography presents many nuances and complex interactions that challenge both student and instructor. Time and instrumentation provide major obstacles to a thorough examination of these details in the laboratory. Modern chromatographic method-development software provides an opportunity to overcome this,…
ERIC Educational Resources Information Center
Marchewka, Barbara Turco
1978-01-01
This science teacher's laboratory is a pond within walking distance of his school that provides a stimulating environment for exploring the natural world. With simple materials students practice making careful observations, taking measurements and compiling and graphing information for their science studies. They also extend their pond experiences…
NASA Astrophysics Data System (ADS)
Pope, Sandi R.; Tolleson, Tonya D.; Williams, R. Jill; Underhill, Russell D.; Deal, S. Todd
1998-06-01
At Georgia Southern University, we offer a sophomore-level introductory biochemistry course that is aimed at nutrition and chemistry education majors. The laboratory portion of this course has long lacked an experimental introduction to enzymes. We have developed a simple enzyme assay utilizing lactase enzyme from crushed LactAid tablets and a 5% lactose solution ("synthetic milk"). In the experiment, the students assay the activity of the enzyme on the "synthetic milk" at pHs of approximately 1, 6, and 8 with the stated goal of determining where lactose functions in the digestive tract. The activity of the lactase may be followed chromatographically or spectrophotometrically. The experiment, which is actually a simple pH assay, is easily implemented in allied health chemistry laboratory courses and readily lends itself to adaptation for more complex kinetic assays in upper-level biochemistry laboratory courses. The experimental details, including a list of required supplies and hints for implementation, are provided.
A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.
Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius
2017-01-01
The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.
Effects of shear load on frictional healing
NASA Astrophysics Data System (ADS)
Ryan, K. L.; Marone, C.
2014-12-01
During the seismic cycle of repeated earthquake failure, faults regain strength in a process known as frictional healing. Laboratory studies have played a central role in illuminating the processes of frictional healing and fault re-strengthening. These studies have also provided the foundation for laboratory-derived friction constitutive laws, which have been used extensively to model earthquake dynamics. We conducted laboratory experiments to assess the affect of shear load on frictional healing. Frictional healing is quantified during slide-hold-slide (SHS) tests, which serve as a simple laboratory analog for the seismic cycle in which earthquakes (slide) are followed by interseismic quiescence (hold). We studied bare surfaces of Westerly granite and layers of Westerly granite gouge (thickness of 3 mm) at normal stresses from 4-25 MPa, relative humidity of 40-60%, and loading and unloading velocities of 10-300 μm/s. During the hold period of SHS tests, shear stress on the sample was partially removed to investigate the effects of shear load on frictional healing and to isolate time- and slip-dependent effects on fault healing. Preliminary results are consistent with existing works and indicate that frictional healing increases with the logarithm of hold time and decreases with normalized shear stress τ/τf during the hold. During SHS tests with hold periods of 100 seconds, healing values ranged from (0.013-0.014) for τ/τf = 1 to (0.059-0.063) for τ/τf = 0, where τ is the shear stress during the hold period and τf is the shear stress during steady frictional sliding. Experiments on bare rock surfaces and with natural and synthetic fault gouge materials are in progress. Conventional SHS tests (i.e. τ/τf = 1) are adequately described by the rate and state friction laws. However, previous experiments in granular quartz suggest that zero-stress SHS tests are not well characterized by either the Dieterich or Ruina state evolution laws. We are investigating the processes that produce shear stress dependent frictional healing, alternate forms of the state evolution law, and comparing results for friction of bare rock surfaces and granular fault gouge.
Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J
2016-01-01
Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive control will benefit inter-laboratory validation of ELISA assays and serve as quality control (QC) reagents for Ov16 RDTs at different points of the supply chain from manufacturer to field use.
ERIC Educational Resources Information Center
Lisovskiy, V.; Yegorenkov, V.
2009-01-01
In this paper, we propose a simple method of observing the collision-dominated Child-Langmuir law in the course of an undergraduate laboratory work devoted to studying the properties of gas discharges. To this end we employ the dc gas discharge whose properties are studied in sufficient detail. The undergraduate laboratory work itself is reduced…
Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria.
Lucchi, Naomi W; Demas, Allison; Narayanan, Jothikumar; Sumari, Deborah; Kabanywanyi, Abdunoor; Kachur, S Patrick; Barnwell, John W; Udhayakumar, Venkatachalam
2010-10-29
Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.
Evaluation of an online, case-based interactive approach to teaching pathophysiology.
Van Dijken, Pieter Canham; Thévoz, Sara; Jucker-Kupper, Patrick; Feihl, François; Bonvin, Raphaël; Waeber, Bernard
2008-06-01
The aim of this study was to evaluate a new pedagogical approach in teaching fluid, electrolyte and acid-base pathophysiology in undergraduate students. This approach comprises traditional lectures, the study of clinical cases on the web and a final interactive discussion of these cases in the classroom. When on the web, the students are asked to select laboratory tests that seem most appropriate to understand the pathophysiological condition underlying the clinical case. The percentage of students having chosen a given test is made available to the teacher who uses it in an interactive session to stimulate discussion with the whole class of students. The same teacher used the same case studies during 2 consecutive years during the third year of the curriculum. The majority of students answered the questions on the web as requested and evaluated positively their experience with this form of teaching and learning. Complementing traditional lectures with online case-based studies and interactive group discussions represents, therefore, a simple means to promote the learning and the understanding of complex pathophysiological mechanisms. This simple problem-based approach to teaching and learning may be implemented to cover all fields of medicine.
Kalinina, Marina A; Skvortsov, Dmitry A; Rubtsova, Maria P; Komarova, Ekaterina S; Dontsova, Olga A
2018-06-01
High- and medium-throughput assays are now routine methods for drug screening and toxicology investigations on mammalian cells. However, a simple and cost-effective analysis of cytotoxicity that can be carried out with commonly used laboratory equipment is still required. The developed cytotoxicity assays are based on human cell lines stably expressing eGFP, tdTomato, mCherry, or Katushka2S fluorescent proteins. Red fluorescent proteins exhibit a higher signal-to-noise ratio, due to less interference by medium autofluorescence, in comparison to green fluorescent protein. Measurements have been performed on a fluorescence scanner, a plate fluorimeter, and a camera photodocumentation system. For a 96-well plate assay, the sensitivity per well and the measurement duration were 250 cells and 15 min for the scanner, 500 cells and 2 min for the plate fluorimeter, and 1000 cells and less than 1 min for the camera detection. These sensitivities are similar to commonly used MTT (tetrazolium dye) assays. The used scanner and the camera had not been previously applied for cytotoxicity evaluation. An image processing scheme for the high-resolution scanner is proposed that significantly diminishes the number of control wells, even for a library containing fluorescent substances. The suggested cytotoxicity assay has been verified by measurements of the cytotoxicity of several well-known cytotoxic drugs and further applied to test a set of novel bacteriotoxic compounds in a medium-throughput format. The fluorescent signal of living cells is detected without disturbing them and adding any reagents, thus allowing to investigate time-dependent cytotoxicity effects on the same sample of cells. A fast, simple and cost-effective assay is suggested for cytotoxicity evaluation based on mammalian cells expressing fluorescent proteins and commonly used laboratory equipment.
Simple optical method of qualitative assessment of sperm motility: preliminary results
NASA Astrophysics Data System (ADS)
Sozanska, Agnieszka; Kolwas, Krystyna; Galas, Jacek; Blocki, Narcyz; Czyzewski, Adam
2005-09-01
The examination of quality of the sperm ejaculate is one of the most important steps in artificial fertilization procedure. The main aim of semen storage centres is to characterise the best semen quality for fertilization. Reliable information about sperm motility is also one the most important parameters for in vitro laboratory procedures. There exist very expensive automated methods for semen analysis but they are unachievable for most of laboratories and semen storage centres. Motivation for this study is to elaborate a simple, cheap, objective and repeatable method for semen motility assessment. The method enables to detect even small changes in motility introduced by medical, physical or chemical factors. To test the reliability of the method we used cryopreserved bull semen from Lowicz Semen Storage Centre. The examined sperm specimen was warmed in water bath and then centrifuged. The best semen was collected by the swim-up technique and diluted to a proper concentration. Several semen concentrations and dilutions were tested in order to find the best probe parameters giving repeatable results. For semen visualization we used the phase-contrast microscope with a CCD camera. A PC computer was used to acquire and to analyse the data. The microscope table equipped with a microscope glass pool 0.7mm deep instead of some conventional plane microscope slides was stabilised at the temperature of 37°C. The main idea of our method is based on a numerical processing of the optical contrast of the sperm images which illustrates the dynamics of the sperm cells movement and on appropriate analysis of a grey scale level of the superimposed images. An elaborated numerical algorithm allows us to find the relative amount of motile sperm cells. The proposed method of sperm motility assessment seems to be objective and repeatable.
Correlations for Saturation Efficiency of Evaporative Cooling Pads
NASA Astrophysics Data System (ADS)
Jain, J. K.; Hindoliya, D. A.
2014-01-01
This paper presents some experimental investigations to obtain correlations for saturation efficiency of evaporative cooling pads. Two commonly used materials namely aspen and khus fibers along with new materials namely coconut fibers and palash fibers were tested in a laboratory using suitably fabricated test setup. Simple mathematical correlations have been developed for calculating saturation efficiency of evaporating cooling pads which can be used to predict their performance at any desired mass flow rate. Performances of four different pad materials were also compared using developed correlations. An attempt was made to test two new materials (i.e. fibers of palash wood and coconut) to check their suitability as wetted media for evaporative cooling pads. It was found that Palash wood fibers offered highest saturation efficiency compared to that of other existing materials such as aspen and khus fibers at different mass flow rate of air.
Moscow Test Well, INEL Oversight Program: Aqueous geochemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCurry, M.; Fromm, J.; Welhan, J.
1992-09-29
This report presents a summary and interpretation of data gathered during sampling of the Moscow Test Well at Moscow, Idaho during April and May of 1992. The principal objectives of this chemical survey were to validate sampling procedures with a new straddle packer sampling tool in a previously hydrologically well characterized and simple sampling environment, and to compare analytical results from two independent labs for reproducibility of analytical results. Analytes included a wide range of metals, anions, nutrients, BNA`s, and VOC`s. Secondary objectives included analyzing of waters from a large distilled water tank (utilized for all field laboratory purposes asmore » ``pure`` stock water), of water which passed through a steamer used to clean the packer, and of rinsates from the packer tool itself before it was lowered into the test well. Analyses were also obtained of blanks and spikes for data validation purposes.« less
Banchongaksorn, T; Prajakwong, S; Rooney, W; Vickers, P
1997-06-01
The rapid manual ParaSight-F test of Plasmodium falciparum malaria, an antigen capture test for detecting trophozoite-derived histidine rich protein-2 (PF HRP-2), is simple to perform and provides a definite diagnosis within 10 minutes. During an operational trial at health centers and mobile malaria units where microscopical diagnosis is not available and using defined symptom screening criteria, 3,361 subjects were tested yielding 618 positives (18.4%) for PF-HRP-2 by ParaSight-F. Microscopic examination of the same subjects by thick blood film examined 7 days later at a malaria clinic showed 578 falciparum, and 349 vivax and mixed infection (F+V) 41. The technology proved highly effective in detecting falciparum malaria at the peripheral levels where access to malaria laboratory services are difficult, thus allowing immediate administration of a complete course of treatment in the absence of a microscopic examination.
Spin Entanglement Witness for Quantum Gravity.
Bose, Sougato; Mazumdar, Anupam; Morley, Gavin W; Ulbricht, Hendrik; Toroš, Marko; Paternostro, Mauro; Geraci, Andrew A; Barker, Peter F; Kim, M S; Milburn, Gerard
2017-12-15
Understanding gravity in the framework of quantum mechanics is one of the great challenges in modern physics. However, the lack of empirical evidence has lead to a debate on whether gravity is a quantum entity. Despite varied proposed probes for quantum gravity, it is fair to say that there are no feasible ideas yet to test its quantum coherent behavior directly in a laboratory experiment. Here, we introduce an idea for such a test based on the principle that two objects cannot be entangled without a quantum mediator. We show that despite the weakness of gravity, the phase evolution induced by the gravitational interaction of two micron size test masses in adjacent matter-wave interferometers can detectably entangle them even when they are placed far apart enough to keep Casimir-Polder forces at bay. We provide a prescription for witnessing this entanglement, which certifies gravity as a quantum coherent mediator, through simple spin correlation measurements.
Spin Entanglement Witness for Quantum Gravity
NASA Astrophysics Data System (ADS)
Bose, Sougato; Mazumdar, Anupam; Morley, Gavin W.; Ulbricht, Hendrik; Toroš, Marko; Paternostro, Mauro; Geraci, Andrew A.; Barker, Peter F.; Kim, M. S.; Milburn, Gerard
2017-12-01
Understanding gravity in the framework of quantum mechanics is one of the great challenges in modern physics. However, the lack of empirical evidence has lead to a debate on whether gravity is a quantum entity. Despite varied proposed probes for quantum gravity, it is fair to say that there are no feasible ideas yet to test its quantum coherent behavior directly in a laboratory experiment. Here, we introduce an idea for such a test based on the principle that two objects cannot be entangled without a quantum mediator. We show that despite the weakness of gravity, the phase evolution induced by the gravitational interaction of two micron size test masses in adjacent matter-wave interferometers can detectably entangle them even when they are placed far apart enough to keep Casimir-Polder forces at bay. We provide a prescription for witnessing this entanglement, which certifies gravity as a quantum coherent mediator, through simple spin correlation measurements.
Joseph, George; Devi, Ranjani; Marley, Elaine C; Leeman, David
2018-05-01
Single- and multilaboratory testing data have provided systematic scientific evidence that a simple, selective, accurate, and precise method can be used as a potential candidate reference method for dispute resolution in determining total biotin in all forms of infant, adult, and/or pediatric formula. Using LC coupled with immunoaffinity column cleanup extraction, the method fully meets the intended purpose and applicability statement in AOAC Standard Method Performance Requirement 2014.005. The method was applied to a cross-section of infant formula and adult nutritional matrixes, and acceptable precision and accuracy were established. The analytical platform is inexpensive, and the method can be used in almost any laboratory worldwide with basic facilities. The immunoaffinity column cleanup extraction is the key step to successful analysis.
Prenatal diagnosis of i(18q) and dup(18q) cases by quantitative fluorescent PCR
Castro-Volio, Isabel; Ortíz-Morales, Fernando; Valle-Bourrouet, Luisa; Malespín-Bendaña, Wendy
2013-01-01
Particular sonographic fetal malformations are common in chromosome 18 aberrations, requiring invasive prenatal tests to confirm the diagnosis. Karyotyping is the gold standard assay in these cases, although it is a high complexity, expensive and approximately 2 weeks turnaround time test. On the contrary, quantitative fluorescent PCR is considered an accurate, simple, low cost and rapid assay, particularly useful for the diagnosis of aneuploidies of chromosomes 13, 18 and 21 and for the detection of maternal cell contamination of the sample. Clinical presentation of two cases of rare chromosome 18 defects, diagnosed using both techniques. One case was an isochromosome and the other was a partial duplication. Quantitative fluorescent PCR was an invaluable tool for the cytogenetics laboratory PMID:24045756
Yan, Shoubao; Chen, Xiangsong; Wu, Jingyong; Wang, Pingchao
2013-07-01
The aim of this study was to develop a bioprocess to produce ethanol from food waste at laboratory, semipilot and pilot scales. Laboratory tests demonstrated that ethanol fermentation with reducing sugar concentration of 200 g/L, inoculum size of 2 % (Initial cell number was 2 × 10⁶ CFU/mL) and addition of YEP (3 g/L of yeast extract and 5 g/L of peptone) was the best choice. The maximum ethanol concentration in laboratory scale (93.86 ± 1.15 g/L) was in satisfactory with semipilot scale (93.79 ± 1.11 g/L), but lower than that (96.46 ± 1.12 g/L) of pilot-scale. Similar ethanol yield and volumetric ethanol productivity of 0.47 ± 0.02 g/g, 1.56 ± 0.03 g/L/h and 0.47 ± 0.03 g/g, 1.56 ± 0.03 g/L/h after 60 h of fermentation in laboratory and semipilot fermentors, respectively, however, both were lower than that (0.48 ± 0.02 g/g, 1.79 ± 0.03 g/L/h) of pilot reactor. In addition, simple models were developed to predict the fermentation kinetics during the scale-up process and they were successfully applied to simulate experimental results.
ERIC Educational Resources Information Center
Touati, Faiza; McGuigan, Kevin G.; Cassidy, John
2007-01-01
A simple method of casting with a Ti[O[subscript]2]/polyvinylchloride (PVC) composite layer was used to describe the behavior of coated electrodes. The system demonstrated that even with low energy light sources, an enhancement of the oxidation efficiency is possible.
Simple Analysis of Historical Lime Mortars
ERIC Educational Resources Information Center
Pires, Joa~o
2015-01-01
A laboratory experiment is described in which a simple characterization of a historical lime mortar is made by the determination of its approximate composition by a gravimetric method. Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD) are also used for the qualitative characterization of the lime mortar components. These…
Aquilino, Mónica; Martínez-Guitarte, Jose Luis; García, Pilar; Beltrán, Eulalia Maria; Fernández, Carlos; Sánchez-Argüello, Paloma
2018-06-09
Post-treatment wastewater reuses are diverse. Recreational and environmental restoration uses of reclaimed water (RW) can be potentially harmful to aquatic organisms. In this work the freshwater snail Physa acuta was exposed to RW (100%) and its dilution (RW 50%). A simple laboratory mixture of three emerging pollutants was used to address the complex problem of mixture toxicity of RW. Hence fortified reclaimed water (FRW), obtained by adding fluoxetine (400 μg FLX/L), perfluorooctane sulphonic acid (90 μg PFOS/L) and methylparaben (9 μg MP/L), was tested at two dilution percentages: 100% and 50%. The effects of the laboratory mixture of FLX, PFOS and MP on the test medium were also studied. Long-lasting effects, together with early molecular responses, were assessed. Fecundity (cumulative egg production) over 21 days and the hatching of produced eggs (F1) after another 21-day embryonic exposure were monitored. The gene expression of three genes was analysed after 24 h of exposure: two endocrine-related nuclear receptors (ERR and RXR) and one stress protein gene (Hsp70). This reproduction test, with additional assessments of the F1 recovered eggs' hatching success, showed that both RW and FRW significantly reduced fecundity. F1 hatching was affected only by FRW. The gene expression results showed that the RXR response was strikingly similar to the fecundity response, which suggests that this nuclear receptor is involved in the reproductive pathways of gastropods. ERR remained virtually unaltered. Hsp70 was overexpressed by the laboratory mixture in the test medium, but no effect was observed in the fortification of RW. This opposite effect and lack of response for F1 hatching produced by the laboratory mixture in the test medium highlighted the difficulty of predicting mixture effects. The experimental approach allowed us to test the effects caused by RW on P. acuta at different biological organisation levels. Thus, the combination of molecular biomarkers and ecological relevant endpoints is a good strategy to test complex mixtures like RW as it provides a framework to link mechanisms of action and whole organism effects when it is almost impossible to detect the pollutant(s) that cause toxic effects. Published by Elsevier B.V.
Earthquake and failure forecasting in real-time: A Forecasting Model Testing Centre
NASA Astrophysics Data System (ADS)
Filgueira, Rosa; Atkinson, Malcolm; Bell, Andrew; Main, Ian; Boon, Steven; Meredith, Philip
2013-04-01
Across Europe there are a large number of rock deformation laboratories, each of which runs many experiments. Similarly there are a large number of theoretical rock physicists who develop constitutive and computational models both for rock deformation and changes in geophysical properties. Here we consider how to open up opportunities for sharing experimental data in a way that is integrated with multiple hypothesis testing. We present a prototype for a new forecasting model testing centre based on e-infrastructures for capturing and sharing data and models to accelerate the Rock Physicist (RP) research. This proposal is triggered by our work on data assimilation in the NERC EFFORT (Earthquake and Failure Forecasting in Real Time) project, using data provided by the NERC CREEP 2 experimental project as a test case. EFFORT is a multi-disciplinary collaboration between Geoscientists, Rock Physicists and Computer Scientist. Brittle failure of the crust is likely to play a key role in controlling the timing of a range of geophysical hazards, such as volcanic eruptions, yet the predictability of brittle failure is unknown. Our aim is to provide a facility for developing and testing models to forecast brittle failure in experimental and natural data. Model testing is performed in real-time, verifiably prospective mode, in order to avoid selection biases that are possible in retrospective analyses. The project will ultimately quantify the predictability of brittle failure, and how this predictability scales from simple, controlled laboratory conditions to the complex, uncontrolled real world. Experimental data are collected from controlled laboratory experiments which includes data from the UCL Laboratory and from Creep2 project which will undertake experiments in a deep-sea laboratory. We illustrate the properties of the prototype testing centre by streaming and analysing realistically noisy synthetic data, as an aid to generating and improving testing methodologies in imperfect conditions. The forecasting model testing centre uses a repository to hold all the data and models and a catalogue to hold all the corresponding metadata. It allows to: Data transfer: Upload experimental data: We have developed FAST (Flexible Automated Streaming Transfer) tool to upload data from RP laboratories to the repository. FAST sets up data transfer requirements and selects automatically the transfer protocol. Metadata are automatically created and stored. Web data access: Create synthetic data: Users can choose a generator and supply parameters. Synthetic data are automatically stored with corresponding metadata. Select data and models: Search the metadata using criteria design for RP. The metadata of each data (synthetic or from laboratory) and models are well-described through their respective catalogues accessible by the web portal. Upload models: Upload and store a model with associated metadata. This provide an opportunity to share models. The web portal solicits and creates metadata describing each model. Run model and visualise results: Selected data and a model to be submitted to a High Performance Computational resource hiding technical details. Results are displayed in accelerated time and stored allowing retrieval, inspection and aggregation. The forecasting model testing centre proposed could be integrated into EPOS. Its expected benefits are: Improved the understanding of brittle failure prediction and its scalability to natural phenomena. Accelerated and extensive testing and rapid sharing of insights. Increased impact and visibility of RP and GeoScience research. Resources for education and training. A key challenge is to agree the framework for sharing RP data and models. Our work is provocative first step.
Teaching Sustainability Analysis in Electrical Engineering Lab Courses
ERIC Educational Resources Information Center
Braun, D.
2010-01-01
Laboratory courses represent an incompletely tapped opportunity to teach sustainability concepts. This work introduces and evaluates a simple strategy used to teach sustainability concepts in electrical engineering laboratory courses. The technique would readily adapt to other disciplines. The paper presents assessment data and a wiki containing…
Impact Crater Experiments for Introductory Physics and Astronomy Laboratories
ERIC Educational Resources Information Center
Claycomb, J. R.
2009-01-01
Activity-based collisional analysis is developed for introductory physics and astronomy laboratory experiments. Crushable floral foam is used to investigate the physics of projectiles undergoing completely inelastic collisions with a low-density solid forming impact craters. Simple drop experiments enable determination of the average acceleration,…
A RAPID DNA EXTRACTION METHOD FOR PCR IDENTIFICATION OF FUNGAL INDOOR AIR CONTAMINANTS
Following air sampling, fungal DNA needs to be extracted and purified to a state suitable for laboratory use. Our laboratory has developed a simple method of extraction and purification of fungal DNA appropriate for enzymatic manipulation and polymerase chain reaction (PCR) appli...
Survey of Biochemical Separation Techniques
ERIC Educational Resources Information Center
Nilsson, Melanie R.
2007-01-01
A simple laboratory exercise is illustrated that exposes students to wide range of separation techniques in one laboratory program and provides a nice complement to a project-oriented program. Students have learned the basic principles of syringe filtration, centricon, dialysis, gel filtration and solid-phase extraction methodologies and have got…
Incorporating Basic Optical Microscopy in the Instrumental Analysis Laboratory
ERIC Educational Resources Information Center
Flowers, Paul A.
2011-01-01
A simple and versatile approach to incorporating basic optical microscopy in the undergraduate instrumental analysis laboratory is described. Attaching a miniature CCD spectrometer to the video port of a standard compound microscope yields a visible microspectrophotometer suitable for student investigations of fundamental spectrometry concepts,…
Dendropedagogy: Teaching Botany, Ecology and Statistical Principles through Tree-Ring Studies.
ERIC Educational Resources Information Center
Rubino, Darrin L.; McCarthy, Brian C.
2002-01-01
Develops a simple tree-ring laboratory to demonstrate the basics of dendrochronology. Provides two upper-level laboratory exercises primarily intended to demonstrate the specific dendrochronology subdisciplines of dendroclimatology and dendroecology. Suggests using the exercises separately or in unison as part of a multidisciplinary capstone…
Smit, Ida; Zemlin, Annalise E; Erasmus, Rajiv T
2015-07-01
Demand management is an area of laboratory activity, which is becoming increasingly important. Within the health-care system, demand management can be defined as the use of health resources to maximise its utility. Tygerberg Hospital has introduced an electronic gate-keeping system. Chemistry tests which generate the highest cost are subjected to this system and may be automatically rejected according to a set of rules. This study aimed: (1) to identify the number of chemistry tests rejected by the eGK; (2) to identify which of these rejected tests were subsequently restored and (3) to assess the impact of rejections on clinical outcome and cost-saving. A retrospective audit was conducted to determine the number of chemistry tests rejected and subsequently restored over a 6-month period. The case-notes of patients for whom requested tests previously rejected had been restored were randomly selected and investigated to assess clinical impact. Any cost-saving was calculated. A total of 68,480 tests were subjected to gate-keeping, and 4605 tests (6.7%) were rejected while 679 (14.7%) of these were restored by the requestor phoning the laboratory after obtaining authorisation. After examining a subset of clinical notes it was found that in most cases (80%), patient care was unaffected. The total cost saved was £ 25,387. The majority of the rejected tests were unnecessary and following rejection, real savings were made. Electronic gate-keeping is a simple, effective and sustainable method of demand management. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Rudasingwa, Martin; Soeters, Robert; Bossuyt, Michel
2015-01-01
To strengthen the health care delivery, the Burundian Government in collaboration with international NGOs piloted performance-based financing (PBF) in 2006. The health facilities were assigned - by using a simple matching method - to begin PBF scheme or to continue with the traditional input-based funding. Our objective was to analyse the effect of that PBF scheme on the quality of health services between 2006 and 2008. We conducted the analysis in 16 health facilities with PBF scheme and 13 health facilities without PBF scheme. We analysed the PBF effect by using 58 composite quality indicators of eight health services: Care management, outpatient care, maternity care, prenatal care, family planning, laboratory services, medicines management and materials management. The differences in quality improvement in the two groups of health facilities were performed applying descriptive statistics, a paired non-parametric Wilcoxon Signed Ranks test and a simple difference-in-difference approach at a significance level of 5%. We found an improvement of the quality of care in the PBF group and a significant deterioration in the non-PBF group in the same four health services: care management, outpatient care, maternity care, and prenatal care. The findings suggest a PBF effect of between 38 and 66 percentage points (p<0.001) in the quality scores of care management, outpatient care, prenatal care, and maternal care. We found no PBF effect on clinical support services: laboratory services, medicines management, and material management. The PBF scheme in Burundi contributed to the improvement of the health services that were strongly under the control of medical personnel (physicians and nurses) in a short time of two years. The clinical support services that did not significantly improved were strongly under the control of laboratory technicians, pharmacists and non-medical personnel. PMID:25948432
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
2015-01-01
Bacterial meningitis is a serious health concern worldwide. Given that meningitis can be fatal and many meningitis cases occurred in high-poverty areas, a simple, low-cost, highly sensitive method is in great need for immediate and early diagnosis of meningitis. Herein, we report a versatile and cost-effective polydimethylsiloxane (PDMS)/paper hybrid microfluidic device integrated with loop-mediated isothermal amplification (LAMP) for the rapid, sensitive, and instrument-free detection of the main meningitis-causing bacteria, Neisseria meningitidis (N. meningitidis). The introduction of paper into the microfluidic device for LAMP reactions enables stable test results over a much longer period of time than a paper-free microfluidic system. This hybrid system also offers versatile functions, by providing not only on-site qualitative diagnostic analysis (i.e., a yes or no answer), but also confirmatory testing and quantitative analysis in laboratory settings. The limit of detection of N. meningitidis is about 3 copies per LAMP zone within 45 min, close to single-bacterium detection sensitivity. In addition, we have achieved simple pathogenic microorganism detection without a laborious sample preparation process and without the use of centrifuges. This low-cost hybrid microfluidic system provides a simple and highly sensitive approach for fast instrument-free diagnosis of N. meningitidis in resource-limited settings. This versatile PDMS/paper microfluidic platform has great potential for the point of care (POC) diagnosis of a wide range of infectious diseases, especially for developing nations. PMID:25019330
Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L
2018-02-01
A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R 2 ), using R 2 as the primary metric of assay agreement. However, the use of R 2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Neuswanger, Jason R.; Wipfli, Mark S.; Rosenberger, Amanda E.; Hughes, Nicholas F.
2017-01-01
Applications of video in fisheries research range from simple biodiversity surveys to three-dimensional (3D) measurement of complex swimming, schooling, feeding, and territorial behaviors. However, researchers lack a transparently developed, easy-to-use, general purpose tool for 3D video measurement and event logging. Thus, we developed a new measurement system, with freely available, user-friendly software, easily obtained hardware, and flexible underlying mathematical methods capable of high precision and accuracy. The software, VidSync, allows users to efficiently record, organize, and navigate complex 2D or 3D measurements of fish and their physical habitats. Laboratory tests showed submillimetre accuracy in length measurements of 50.8 mm targets at close range, with increasing errors (mostly <1%) at longer range and for longer targets. A field test on juvenile Chinook salmon (Oncorhynchus tshawytscha) feeding behavior in Alaska streams found that individuals within aggregations avoided the immediate proximity of their competitors, out to a distance of 1.0 to 2.9 body lengths. This system makes 3D video measurement a practical tool for laboratory and field studies of aquatic or terrestrial animal behavior and ecology.
Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay
2018-02-28
Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky laboratory equipments. Practical courses of biochemistry at high school or undergraduate levels are often affected by these complications. Two dimensional gel electrophoresis technique (2D-PAGE) used for resolving thousands of proteins in a gel is a combination of isoelectric focusing (first dimension gel electrophoresis technique) and sodium-dodecylsulphate PAGE (second dimension gel electrophoresis technique or SDS-PAGE). Two different laboratory equipments are needed to carry out effective 2D-PAGE technique, which also invites extra burden to the school laboratory. Here, we describe a low cost, time saving and simple gel cassette for protein 2D-PAGE technique that uses easily fabricated components and routine off-the-shelf materials. The performance of the apparatus was verified in a practical exercise by a group of high school students with positive outcomes. © 2018 by The International Union of Biochemistry and Molecular Biology, 2018. © 2018 The International Union of Biochemistry and Molecular Biology.
Mass Spectrometry for the Masses
ERIC Educational Resources Information Center
Persinger, Jared D.; Hoops, Geoffrey, C.; Samide, Michael J.
2004-01-01
A simple, qualitative experiment is developed for implementation, where the gas chromatography-mass spectrometry (GC-MS) plays an important role, into the laboratory curriculum of a chemistry course designed for nonscience majors. This laboratory experiment is well suited for the students as it helps them to determine the validity of their…
A Laboratory Exercise with Related Rates.
ERIC Educational Resources Information Center
Sworder, Steven C.
A laboratory experiment, based on a simple electric circuit that can be used to demonstrate the existence of real-world "related rates" problems, is outlined and an equation for voltage across the capacitor terminals during discharge is derived. The necessary materials, setup methods, and experimental problems are described. A student laboratory…
Waterless Condensers for the Teaching Laboratory: An Adaptation of Traditional Glassware
ERIC Educational Resources Information Center
Baum, Erich W.; Esteb, John J.; Wilson, Anne M.
2014-01-01
A simple adaptation of traditional "chemistry kit" condensers for the organic chemistry teaching laboratory is described. These waterless condensers have been employed safely with most solvents. They can be easily fabricated, stored, and used in the same manner as water-cooled condensers. These condensers were utilized in several…
A Unit Cell Laboratory Experiment: Marbles, Magnets, and Stacking Arrangements
ERIC Educational Resources Information Center
Collins, David C.
2011-01-01
An undergraduate first-semester general chemistry laboratory experiment introducing face-centered, body-centered, and simple cubic unit cells is presented. Emphasis is placed on the stacking arrangement of solid spheres used to produce a particular unit cell. Marbles and spherical magnets are employed to prepare each stacking arrangement. Packing…
Colorimetric Quantification and in Situ Detection of Collagen
ERIC Educational Resources Information Center
Esteban, Francisco J.; del Moral, Maria L.; Sanchez-Lopez, Ana M.; Blanco, Santos; Jimenez, Ana; Hernandez, Raquel; Pedrosa, Juan A.; Peinado, Maria A.
2005-01-01
A simple multidisciplinary and inexpensive laboratory exercise is proposed, in which the undergraduate student may correlate biochemical and anatomical findings. The entire practical session can be completed in one 2.5-3 hour laboratory period, and consists of the quantification of collagen and total protein content from tissue sections--without…
A Laboratory Demonstration Illustrating Bioseparations Using Colorful Proteins
ERIC Educational Resources Information Center
Cohen, Theodore M.; Rohs, Amanda E.; Lefebvre, Brian G.
2008-01-01
A simple in class laboratory illustrating the principles of ion exchange chromatography as a bioseparation technique is described. A protein's isoelectric point as a driving force for ion exchange chromatography is easily demonstrated by using combinations of proteins with natural color or fluorescence, such as DsRed2, enhanced green fluorescent…
A laboratory experiment was conducted to investigate the transfer of organic contaminants from an environmentally contaminated marine sediment through a simple marine food chain. The infaunal polychaete, Nereis virens, was exposed to contaminated sediment collected from the Passa...
Simple Laboratory Exercise for Induction of Beta-Mannanase from "Aspergillus niger"
ERIC Educational Resources Information Center
Mulimani, V. H.; Naganagouda, K.
2010-01-01
This laboratory experiment was designed for Biochemistry, Biotechnology, Microbiology, and Food Technology students of undergraduate and postgraduate courses. The experiment shows the advantages of using agricultural waste, copra mannan as potent inducer of [beta]-mannanase. The students were able to compare the enzyme induction by commercial…
A Novel Laboratory Activity for Teaching about the Evolution of Multicellularity
ERIC Educational Resources Information Center
Ratcliff, William C.; Raney, Allison; Westreich, Sam; Cotner, Sehoya
2014-01-01
The evolution of complexity remains one of the most challenging topics in biology to teach effectively. We present a novel laboratory activity, modeled on a recent experimental breakthrough, in which students experimentally evolve simple multicellularity using single-celled yeast ("Saccharomyces cerevisiae"). By simply selecting for…
A Simple Photochemical Experiment for the Advanced Laboratory.
ERIC Educational Resources Information Center
Rosenfeld, Stuart M.
1986-01-01
Describes an experiment to provide students with: (1) an introduction to photochemical techniques and theory; (2) an experience with semimicro techniques; (3) an application of carbon-14 nuclear magnetic resonance; and (4) a laboratory with some qualities of a genuine experiment. These criteria are met in the photooxidation of 9,…
A New Application for Radioimmunoassay: Measurement of Thermodynamic Constants.
ERIC Educational Resources Information Center
Angstadt, Carol N.; And Others
1983-01-01
Describes a laboratory experiment in which an equilibrium radioimmunoassay (RIA) is used to estimate thermodynamic parameters such as equilibrium constants. The experiment is simple and inexpensive, and it introduces a technique that is important in the clinical chemistry and research laboratory. Background information, procedures, and results are…
Okada, Morihiro; Miller, Thomas C; Roediger, Julia; Shi, Yun-Bo; Schech, Joseph Mat
2017-09-01
Various animal models are indispensible in biomedical research. Increasing awareness and regulations have prompted the adaptation of more humane approaches in the use of laboratory animals. With the development of easier and faster methodologies to generate genetically altered animals, convenient and humane methods to genotype these animals are important for research involving such animals. Here, we report skin swabbing as a simple and noninvasive method for extracting genomic DNA from mice and frogs for genotyping. We show that this method is highly reliable and suitable for both immature and adult animals. Our approach allows a simpler and more humane approach for genotyping vertebrate animals.
Dubé, Philippe-Antoine; Imbeau, Daniel; Dubeau, Denise; Auger, Isabelle; Leone, Mario
2015-01-01
Individual heart rate (HR) to workload relationships were determined using 93 submaximal step-tests administered to 26 healthy participants attending physical activities in a university training centre (laboratory study) and 41 experienced forest workers (field study). Predicted maximum aerobic capacity (MAC) was compared to measured MAC from a maximal treadmill test (laboratory study) to test the effect of two age-predicted maximum HR Equations (220-age and 207-0.7 × age) and two clothing insulation levels (0.4 and 0.91 clo) during the step-test. Work metabolism (WM) estimated from forest work HR was compared against concurrent work V̇O2 measurements while taking into account the HR thermal component. Results show that MAC and WM can be accurately predicted from work HR measurements and simple regression models developed in this study (1% group mean prediction bias and up to 25% expected prediction bias for a single individual). Clothing insulation had no impact on predicted MAC nor age-predicted maximum HR equations. Practitioner summary: This study sheds light on four practical methodological issues faced by practitioners regarding the use of HR methodology to assess WM in actual work environments. More specifically, the effect of wearing work clothes and the use of two different maximum HR prediction equations on the ability of a submaximal step-test to assess MAC are examined, as well as the accuracy of using an individual's step-test HR to workload relationship to predict WM from HR data collected during actual work in the presence of thermal stress.
Relating results from earthworm toxicity tests to agricultural soil
Beyer, W.N.; Greig-Smith, P.W.
1992-01-01
The artificial soil tests of the European Economic Community and of the Organization for Economic Cooperation produce data relating earthworm mortality to pesticide concentrations in soil under laboratory conditions. To apply these results to agricultural soils it is necessary to relate these concentrations to amounts of pesticide applied per area. This paper reviews the relevant published literature and suggests a simple relation for regulatory use. Hazards to earthworms from pesticides are suggested to be greatest soon after application, when the pesticides may be concentrated in a soil layer a few millimeters thick. For estimating exposure of earthworms, however, a thicker soil layer should be considered, to account for their movement through soil. During favorable weather conditions, earthworms belonging to species appropriate to the artificial soil test have been reported to confine their activity to a layer about 5 cm. If a 5-cm layer is accepted as relevant for regulatory purposes, then an application of 1 kg/ha would be equivalent to 1-67 ppm (dry) in the artificial soil test.
Tyson, Adam L.; Hilton, Stephen T.; Andreae, Laura C.
2015-01-01
The cost of 3D printing has reduced dramatically over the last few years and is now within reach of many scientific laboratories. This work presents an example of how 3D printing can be applied to the development of custom laboratory equipment that is specifically adapted for use with the novel brain tissue clearing technique, CLARITY. A simple, freely available online software tool was used, along with consumer-grade equipment, to produce a brain slicing chamber and a combined antibody staining and imaging chamber. Using standard 3D printers we were able to produce research-grade parts in an iterative manner at a fraction of the cost of commercial equipment. 3D printing provides a reproducible, flexible, simple and cost-effective method for researchers to produce the equipment needed to quickly adopt new methods. PMID:25797056
Bird, Patrick; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Jechorek, Robert
2014-01-01
The 3M™ Petriflm™ Salmonella Express (SALX) System is a simple, ready-to-use chromogenic culture medium system for the rapid qualitative detection and biochemical confirmation of Salmonella spp. in food and food process environmental samples. The 3M Petrifilm SALX System was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) Microbiology Laboratory Guidebook (MLG) 4.07 (2013) Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products and Carcass and Environmental Sponges for raw ground beef and the U.S. Food and Drug Administration Bacteriological Analytical Manual (FDA/BAM) Chapter 5, Salmonella (2011) reference method for dry dog food following the current AOAC validation guidelines. For this study, a total of 17 laboratories located throughout the continental United States evaluated 1872 test portions. For the 3M Petrifilm SALX System, raw ground beef was analyzed using 25 g test portions, and dry dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each inatrix were analyzed. The two matrices were artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). Each inoculation level was statistically analyzed using the probability of detection statistical model. For the raw ground beef and dry dog food test portions, no significant differences at the 95% confidence interval were observed in the number of positive samples detected by the 3M Petrifilm SALX System versus either the USDA/FSIS-MLG or FDA/BAM methods.
Vanadium Flow Battery Electrolyte Synthesis via Chemical Reduction of V2O5 in Aqueous HCl and H2SO4.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Small, Leo J.; Pratt, Harry; Staiger, Chad
We report a simple method to synthesize V 4+ (VO 2+ ) electrolytes as feedstock for all- vanadium redox flow batteries (RFB). By dissolving V 2 O 5 in aqueous HCl and H 2 SO 4 , subsequently adding glycerol as a reducing agent, we have demonstrated an inexpensive route for electrolyte synthesis to concentrations >2.5 M V 4+ (VO 2+ ). Electrochemical analysis and testing of laboratory scale RFB demonstrate improved thermal stability across a wider temperature range (-10-65 degC) for V 4+ (VO 2+ ) electrolytes in HCl compared to in H 2 SO 4 electrolytes.
Continuous in vitro evolution of catalytic function.
Wright, M C; Joyce, G F
1997-04-25
A population of RNA molecules that catalyze the template-directed ligation of RNA substrates was made to evolve in a continuous manner in the test tube. A simple serial transfer procedure was used to achieve approximately 300 successive rounds of catalysis and selective amplification in 52 hours. During this time, the population size was maintained against an overall dilution of 3 x 10(298). Both the catalytic rate and amplification rate of the RNAs improved substantially as a consequence of mutations that accumulated during the evolution process. Continuous in vitro evolution makes it possible to maintain laboratory "cultures" of catalytic molecules that can be perpetuated indefinitely.
Weight-controlled capillary viscometer
NASA Astrophysics Data System (ADS)
Digilov, Rafael M.; Reiner, M.
2005-11-01
The draining of a water column through a vertical discharge capillary tube is examined with the aid of a force sensor. The change of the mass of the liquid in the column with time is found to be not purely exponential as implied by Poiseuille's law. Using observed residuals associated with a kinetic energy correction, an approximate formula for the mass as a function of time is derived and excellent agreement with experimental data is attained. These results are verified by a viscosity test of distilled water at room temperature. A simple and inexpensive weight-controlled capillary viscometer is proposed that is especially suitable for undergraduate physics and chemistry laboratories.
Continuous in vitro evolution of catalytic function
NASA Technical Reports Server (NTRS)
Wright, M. C.; Joyce, G. F.
1997-01-01
A population of RNA molecules that catalyze the template-directed ligation of RNA substrates was made to evolve in a continuous manner in the test tube. A simple serial transfer procedure was used to achieve approximately 300 successive rounds of catalysis and selective amplification in 52 hours. During this time, the population size was maintained against an overall dilution of 3 x 10(298). Both the catalytic rate and amplification rate of the RNAs improved substantially as a consequence of mutations that accumulated during the evolution process. Continuous in vitro evolution makes it possible to maintain laboratory "cultures" of catalytic molecules that can be perpetuated indefinitely.
Assessment of the MHD capability in the ATHENA code using data from the ALEX facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, P.A.
1989-03-01
The ATHENA (Advanced Thermal Hydraulic Energy Network Analyzer) code is a system transient analysis code with multi-loop, multi-fluid capabilities, which is available to the fusion community at the National Magnetic Fusion Energy Computing Center (NMFECC). The work reported here assesses the ATHENA magnetohydrodynamic (MHD) pressure drop model for liquid metals flowing through a strong magnetic field. An ATHENA model was developed for two simple geometry, adiabatic test sections used in the Argonne Liquid Metal Experiment (ALEX) at Argonne National Laboratory (ANL). The pressure drops calculated by ATHENA agreed well with the experimental results from the ALEX facility.
Tobacco Agar, a New Medium for Differentiating Candida dubliniensis from Candida albicans
Khan, Zia U.; Ahmad, Suhail; Mokaddas, Eiman; Chandy, Rachel
2004-01-01
Isolates of Candida dubliniensis may be misidentified as Candida albicans in microbiological laboratories if only the germ tube and/or the chlamydospore test is used for identification to the species level. In this study, we have evaluated the efficacy of tobacco agar for the differentiation of C. dubliniensis from C. albicans. On this medium at 28°C, all 30 C. dubliniensis isolates produced yellowish-brown colonies with hyphal fringes and abundant chlamydospores, whereas 54 C. albicans isolates formed smooth, white-to-cream-colored colonies with no chlamydospore production. This medium provides a simple tool for presumptive differentiation of C. dubliniensis from C. albicans. PMID:15472343
Validation of the ANSR Listeria method for detection of Listeria spp. in environmental samples.
Wendorf, Michael; Feldpausch, Emily; Pinkava, Lisa; Luplow, Karen; Hosking, Edan; Norton, Paul; Biswas, Preetha; Mozola, Mark; Rice, Jennifer
2013-01-01
ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.
Toxoplasmosis serology: an efficient hemagglutination procedure to detect IgG and IgM antibodies.
Camargo, M E; Moura, M E; Leser, P G
1989-01-01
In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo, an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A--rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.
Test of the Angle Detecting Inclined Sensor (ADIS) Technique for Measuring Space Radiation
NASA Astrophysics Data System (ADS)
Connell, J. J.; Lopate, C.; McLaughlin, K. R.
2008-12-01
In February 2008 we exposed an Angle Detecting Inclined Sensor (ADIS) prototype to beams of 150 MeV/u 78Kr and fragments at the National Superconducting Cyclotron Laboratory's (NSCL) Coupled Cyclotron Facility (CCF). ADIS is a highly innovative and uniquely simple detector configuration used to determine the angles of incidence of heavy ions in energetic charged particle instruments. Corrections for angle of incidence are required for good charge and mass separation. An ADIS instrument is under development to fly on the GOES-R series of weather satellites. The prototype tested consisted of three ADIS detectors, two of which were inclined at an angle to the telescope axis, forming the initial detectors in a five-detector telescope stack. By comparing the signals from the ADIS detectors, the angle of incidence may be determined and a pathlength correction applied to charge and mass determinations. Thus, ADIS replaces complex position sensing detectors with a system of simple, reliable and robust Si detectors. Accelerator data were taken at multiple angles to both primary and secondary beams with a spread of energies. This test instrument represents an improvement over the previous ADIS prototype in that it used oval inclined detectors and a much lower-mass support structure, thus reducing the number of events passing through dead material. We will present the results of this test. The ADIS instrument development project was partially funded by NASA under the Living With a Star (LWS) Targeted Research and Technology program (grant NAG5-12493).
Test Waveform Applications for JPL STRS Operating Environment
NASA Technical Reports Server (NTRS)
Lux, James P.; Peters, Kenneth J.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.; Duncan, Courtney B.
2013-01-01
This software demonstrates use of the JPL Space Telecommunications Radio System (STRS) Operating Environment (OE), tests APIs (application programming interfaces) presented by JPL STRS OE, and allows for basic testing of the underlying hardware platform. This software uses the JPL STRS Operating Environment ["JPL Space Tele com - munications Rad io System Operating Environment,"(NPO-4776) NASA Tech Briefs, commercial edition, Vol. 37, No. 1 (January 2013), p. 47] to interact with the JPL-SDR Software Defined Radio developed for the CoNNeCT (COmmunications, Navigation, and Networking rEconfigurable Testbed) Project as part of the SCaN Testbed installed on the International Space Station (ISS). These are the first applications that are compliant with the new NASA STRS Architecture Standard. Several example waveform applications are provided to demonstrate use of the JPL STRS OE for the JPL-SDR platform used for the CoNNeCT Project. The waveforms provide a simple digitizer and playback capability for the SBand RF slice, and a simple digitizer for the GPS slice [CoNNeCT Global Positioning System RF Module, (NPO-47764) NASA Tech Briefs, commercial edition, Vol. 36, No. 3 (March 2012), p. 36]. These waveforms may be used for hardware test, as well as for on-orbit or laboratory checkout. Additional example waveforms implement SpaceWire and timer modules, which can be used for time transfer and demonstration of communication between the two Xilinx FPGAs in the JPLSDR. The waveforms are also compatible with ground-based use of the JPL STRS OE on radio breadboards and Linux.
Development of a simple, rapid, and robust intrathecal catheterization method in the rat.
Mazur, Curt; Fitzsimmons, Bethany; Kamme, Fredrik; Nichols, Brandon; Powers, Berit; Wancewicz, Ed
2017-03-15
The blood brain barrier (BBB) is an impediment to the development of large and highly charged molecules as therapeutics for diseases and injuries of the central nervous system (CNS). Antisense oligonucleotides (ASOs) are large (6000-8000MW) and highly charged and therefore do not cross the BBB. A method of circumventing the blood brain barrier to test ASOs, and other non-BBB penetrant molecules, as CNS therapeutics is the direct administration of these molecules to the CNS tissue or cerebral spinal fluid. We developed a rapid, simple and robust method for the intrathecal catheterization of rats to test putatively therapeutic antisense oligonucleotides. This method utilizes 23-gauge needles, simply constructed ½in. long 19-gauge guide cannulas and 8cm long plastic PE-10 sized catheters. Unlike the cisterna magna approach, this method uses a lumbar approach for intrathecal catheterization with the catheter residing entirely in the cauda equina space minimizing spinal cord compression. Readily available materials and only a few specialized pieces of equipment, which are easily manufactured, are used for this intrathecal catheterization method. This method is easy to learn and has been taught to multiple in house surgeons, collaborators and contract laboratories. Greater than 90% catheterization success is routinely achieved with this method and as many as 100 catheters can be placed and test substance administered in one 6-h period. This method has allowed the pre-clinical testing of hundreds of ASOs as therapeutics for CNS indications. Copyright © 2017 Elsevier B.V. All rights reserved.
MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent
2004-01-01
Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.
Farmer, J J; Carter, G P; Miller, V L; Falkow, S; Wachsmuth, I K
1992-01-01
We evaluated several simple laboratory tests that have been used to identify pathogenic serotypes of Yersinia enterocolitica or to indicate the pathogenic potential of individual strains. A total of 100 strains of Y. enterocolitica were studied, including 25 isolated during five outbreak investigations, 63 from sporadic cases, and 12 from stock cultures. The pyrazinamidase test, which does not depend on the Yersinia virulence plasmid, correctly identified 60 of 63 (95% sensitivity) strains of pathogenic serotypes and 34 of 37 (92% specificity) strains of nonpathogenic serotypes. Salicin fermentation-esculin hydrolysis (25 degrees C, 48 h) correctly identified all 63 (100% sensitivity) strains of the pathogenic serotypes and 34 of 37 (92% specificity) strains of the nonpathogenic serotypes. The results of the pyrazinamidase and salicin-esculin tests disagreed for only 7 of the 100 strains of Y. enterocolitica, and these would require additional testing. Congo red-magnesium oxalate (CR-MOX) agar determines Congo red dye uptake and calcium-dependent growth at 36 degrees C, and small red colonies are present only if the strain contains the Yersinia virulence plasmid. This test has proven to be extremely useful for freshly isolated cultures, but only 15 of 62 strains of pathogenic serotypes that had been stored for 1 to 10 years were CR-MOX positive. None of the 16 strains of Y. enterocolitica serotype O3 fermented D-xylose, so this test easily differentiated strains of this serotype, which now appears to be the most common in the United States. Although antisera that can actually be used to serotype strains of Y. enterocolitica are not readily available, the four simple tests described above can be used to screen for pathogenic serotypes. Images PMID:1400958
Dual Etalon Cross Tilt Order Sorted Spectrometer (DECTOSS)
NASA Astrophysics Data System (ADS)
Kumer, John B.; Rairden, Richard L.; Mitchell, Keith E.; Roche, Aidan E.; Mergenthaler, John L.
2002-11-01
The Dual Etalon Cross Tilt Order Sorted Spectrometer (DECTOSS) uses relatively inexpensive off the shelf components in a small and simple package to provide ultra high spectral resolution over a limited spectral range. For example, the modest first try laboratory test setup DECTOSS we describe in this presentation achieves resolving power ~ 105 on a spectral range of about 1 nm centered near 760 nm. This ultra high spectral resolution facilitates some important atmospheric remote sensing applications including profiling cirrus and/or aerosol above bright reflective surfaces in the O2 A-band and the column measurements of CO and CO2 utilizing solar reflectance spectra. We show details of the how the use of ultra high spectral resolution in the O2 A-band improves the profiling of cirrus and aerosol. The DECTOSS utilizes a Narrow Band Spectral Filter (NBSF), a Low Resolution Etalon (LRE) and a High Resolution Etalon (HRE). Light passing through these elements is focused on to a 2 Dimensional Array Detector (2DAD). Off the shelf, solid etalons with airgap or solid spacer gap are used in this application. In its simplest application this setup utilizes a spatially uniform extended source so that spatial and spectral structure are not confused. In this presentation we'll show 2D spectral data obtained in a desktop test configuration, and in the first try laboratory test setup. These were obtained by illuminating a Lambertian screen with (1) monochromatic light, and (2) with atmospheric absorption spectra in the oxygen (O2) A-band. Extracting the 1D spectra from these data is a work in progress and we show preliminary results compared with (1) solar absorption data obtained with a large Echelle grating spectrometer, and (2) theoretical spectra. We point out areas for improvement in our laboratory test setup, and general improvements in spectral range and sensitivity that are planned for our next generation field test setup.
The Ins and Outs of Breath Holding: Simple Demonstrations of Complex Respiratory Physiology
ERIC Educational Resources Information Center
Skow, Rachel J.; Day, Trevor A.; Fuller, Jonathan E.; Bruce, Christina D.; Steinback, Craig D.
2015-01-01
The physiology of breath holding is complex, and voluntary breath-hold duration is affected by many factors, including practice, psychology, respiratory chemoreflexes, and lung stretch. In this activity, we outline a number of simple laboratory activities or classroom demonstrations that illustrate the complexity of the integrative physiology…
25+ Years of the Hubble Space Telescope and a Simple Error That Cost Millions
ERIC Educational Resources Information Center
Shakerin, Said
2016-01-01
A simple mistake in properly setting up a measuring device caused millions of dollars to be spent in correcting the initial optical failure of the Hubble Space Telescope (HST). This short article is intended as a lesson for a physics laboratory and discussion of errors in measurement.
A Simple Molecular Dynamics Lab to Calculate Viscosity as a Function of Temperature
ERIC Educational Resources Information Center
Eckler, Logan H.; Nee, Matthew J.
2016-01-01
A simple molecular dynamics experiment is described to demonstrate transport properties for the undergraduate physical chemistry laboratory. The AMBER package is used to monitor self-diffusion in "n"-hexane. Scripts (available in the Supporting Information) make the process considerably easier for students, allowing them to focus on the…
USDA-ARS?s Scientific Manuscript database
Pasta is a simple food made from water and durum wheat (Triticum turgidum subsp. durum) semolina. As pasta increases in popularity, studies have endeavored to analyze the attributes that contribute to high quality pasta. Despite being a simple food, the laboratory scale analysis of pasta quality is ...
Thomas, Frank O; Hoffman, Terri L; Handrahan, Diana L; Crapo, Robert O; Snow, Greg
2009-08-01
Portable blood gas analyzer and monitor devices are increasingly being used to direct ventilator therapy. The purpose of this study was to evaluate the "measure of treatment agreement" between portable and laboratory blood gas measurements used in guiding protocol-driven ventilator management. Using National Institutes of Health Acute Respiratory Distress Syndrome network ventilator management guidelines to manage patient care, measurements taken from the Nonin 8500 M pulse oximeter (SpO2), the Novametrix-610 end-tidal CO2 (ETCO2) detector, and the i-STAT 1 (SaO2, PO2, pH, PCO2) were compared with the recommended treatment from paired laboratory ABL-725 (SaCO2, PO2, pH, PCO2) measurements. Four hundred forty-six intubated adult intensive care unit patients were studied prospectively. Except for the ETCO2 (R2 = 0.460), correlation coefficients between portable and laboratory measurements were high (R2 > or = 0.755). Testing for equivalence, the Nonin-SpO2, iSTAT-PO2, iSTAT-pH, and iSTAT-PCO2 were deemed "equivalent" surrogates to paired ABL measurements. Testing for the limits of agreement found only the iSTAT-PCO2 to be an acceptable surrogate measurement. The measure of treatment agreement between the portable and paired laboratory blood gas measurements were Nonin-SpO2 (68%), iSTAT-SaO2 (73%), iSTAT-PO2 (97%), iSTAT-pH (88%), iSTAT-PCO2 (95%), and Novametrix-ETCO2 (60%). Only the iSTAT-PO2 and the iSTAT-PCO2 achieved the > or =95% treatment agreement threshold to be considered as acceptable surrogates to laboratory measurements. : The iSTAT-PO2 and -PCO2 were portable device measurements acceptable as surrogates to standard clinical laboratory blood gas measurements in guiding protocol-directed ventilator management. The "measure of treatment agreement," based on standardized decisions and measurement thresholds of a protocol, provides a simple method for assessing clinical validity of surrogate measurements.
Shiha, G; Seif, S; Eldesoky, A; Elbasiony, M; Soliman, R; Metwally, A; Zalata, K; Mikhail, N
2017-05-01
A simple non-invasive score (Fibrofast, FIB-5) was developed using five routine laboratory tests (ALT, AST, alkaline phosphatase, albumin and platelets count) for the detection of significant hepatic fibrosis in patients with chronic hepatitis C. The FIB-4 index is a non-invasive test for the assessment of liver fibrosis, and a score of ≤1.45 enables the correct identification of patients who have non-significant (F0-1) from significant fibrosis (F2-4), and could avoid liver biopsy. The aim of this study was to compare the performance characteristics of FIB-5 and FIB-4 to differentiate between non-significant and significant fibrosis. A cross-sectional study included 604 chronic HCV patients. All liver biopsies were scored using the METAVIR system. Both FIB-5 and FIB-4 scores were measured and the performance characteristics were calculated using the ROC curve. The performance characteristics of FIB-5 at ≥7.5 and FIB-4 at ≤1.45 for the differentiation between non-significant fibrosis and significant fibrosis were: specificity 94.4%, PPV 85.7%, and specificity 54.9%, PPV 55.7% respectively. FIB-5 score at the new cutoff is superior to FIB-4 index for the differentiation between non-significant and significant fibrosis.
Ferreira, Adriano Martison; Bonesso, Mariana Fávero; Mondelli, Alessandro Lia; da Cunha, Maria de Lourdes Ribeiro de Souza
2012-12-01
The emergence of Staphylococcus spp. not only as human pathogens, but also as reservoirs of antibiotic resistance determinants, requires the development of methods for their rapid and reliable identification in medically important samples. The aim of this study was to compare three phenotypic methods for the identification of Staphylococcus spp. isolated from patients with urinary tract infection using the PCR of the 16S-23S interspace region generating molecular weight patterns (ITR-PCR) as reference. All 57 S. saprophyticus studied were correctly identified using only the novobiocin disk. A rate of agreement of 98.0% was obtained for the simplified battery of biochemical tests in relation to ITR-PCR, whereas the Vitek I system and novobiocin disk showed 81.2% and 89.1% agreement, respectively. No other novobiocin-resistant non-S. saprophyticus strain was identified. Thus, the novobiocin disk is a feasible alternative for the identification of S. saprophyticus in urine samples in laboratories with limited resources. ITR-PCR and the simplified battery of biochemical tests were more reliable than the commercial systems currently available. This study confirms that automated systems are still unable to correctly differentiate CoNS species and that simple, reliable and inexpensive methods can be used for routine identification. Copyright © 2012 Elsevier B.V. All rights reserved.
Ice Accretion with Varying Surface Tension
NASA Technical Reports Server (NTRS)
Bilanin, Alan J.; Anderson, David N.
1995-01-01
During an icing encounter of an aircraft in flight, super-cooled water droplets impinging on an airfoil may splash before freezing. This paper reports tests performed to determine if this effect is significant and uses the results to develop an improved scaling method for use in icing test facilities. Simple laboratory tests showed that drops splash on impact at the Reynolds and Weber numbers typical of icing encounters. Further confirmation of droplet splash came from icing tests performed in the NaSA Lewis Icing Research Tunnel (IRT) with a surfactant added to the spray water to reduce the surface tension. The resulting ice shapes were significantly different from those formed when no surfactant was added to the water. These results suggested that the droplet Weber number must be kept constant to properly scale icing test conditions. Finally, the paper presents a Weber-number-based scaling method and reports results from scaling tests in the IRT in which model size was reduced up to a factor of 3. Scale and reference ice shapes are shown which confirm the effectiveness of this new scaling method.
NASA Technical Reports Server (NTRS)
Laub, Bernard; Grinstead, Jay; Dyakonov, Artem; Venkatapathy, Ethiraj
2011-01-01
Though arc jet testing has been the proven method employed for development testing and certification of TPS and TPS instrumentation, the operational aspects of arc jets limit testing to selected, but constant, conditions. Flight, on the other hand, produces timevarying entry conditions in which the heat flux increases, peaks, and recedes as a vehicle descends through an atmosphere. As a result, we are unable to "test as we fly." Attempts to replicate the time-dependent aerothermal environment of atmospheric entry by varying the arc jet facility operating conditions during a test have proven to be difficult, expensive, and only partially successful. A promising alternative is to rotate the test model exposed to a constant-condition arc jet flow to yield a time-varying test condition at a point on a test article (Fig. 1). The model shape and rotation rate can be engineered so that the heat flux at a point on the model replicates the predicted profile for a particular point on a flight vehicle. This simple concept will enable, for example, calibration of the TPS sensors on the Mars Science Laboratory (MSL) aeroshell for anticipated flight environments.
A novel method of sensing temperatures of magnet coils of SINP-MaPLE plasma device
NASA Astrophysics Data System (ADS)
Pal, A. M.; Bhattacharya, S.; Biswas, S.; Basu, S.; Pal, R.
2014-03-01
A set of 36 magnet coils is used to produce a continuous, uniform magnetic field of about 0.35 Tesla inside the vacuum chamber of the MaPLE Device, a linear laboratory plasma device (3 m long and 0.30 m in diameter) built for studying basic magnetized plasma physics phenomena. To protect the water cooled-coils from serious damage due to overheating temperatures of all the coils are monitored electronically using low cost temperature sensor IC chips, a technique first being used in similar magnet system. Utilizing the Parallel Port of a Personal Computer a novel scheme is used to avoid deploying microprocessor that is associated with involved circuitry and low level programming to address and control the large number of sensors. The simple circuits and a program code to implement the idea are developed, tested and presently in operation. The whole arrangement comes out to be not only attractive, but also simple, economical and easy to install elsewhere.
Simple method for generating adjustable trains of picosecond electron bunches
NASA Astrophysics Data System (ADS)
Muggli, P.; Allen, B.; Yakimenko, V. E.; Park, J.; Babzien, M.; Kusche, K. P.; Kimura, W. D.
2010-05-01
A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.
Evaluation of a pulse control law for flexible spacecraft
NASA Technical Reports Server (NTRS)
1985-01-01
The following analytical and experimental studies were conducted: (1) A simple algorithm was developed to suppress the structural vibrations of 3-dimensional distributed parameter systems, subjected to interface motion and/or directly applied forces. The algorithm is designed to cope with structural oscillations superposed on top of rigid-body motion: a situation identical to that encountered by the SCOLE components. A significant feature of the method is that only local measurements of the structural displacements and velocities relative to the moving frame of reference are needed. (2) A numerical simulation study was conducted on a simple linear finite element model of a cantilevered plate which was subjected to test excitations consisting of impulsive base motion and of nonstationary wide-band random excitation applied at its root. In each situation, the aim was to suppress the vibrations of the plate relative to the moving base. (3) A small mechanical model resembling an aircraft wing was designed and fabricated to investigate the control algorithm under realistic laboratory conditions.
Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique
2017-04-01
An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.
A simple approximation for the current-voltage characteristics of high-power, relativistic diodes
Ekdahl, Carl
2016-06-10
A simple approximation for the current-voltage characteristics of a relativistic electron diode is presented. The approximation is accurate from non-relativistic through relativistic electron energies. Although it is empirically developed, it has many of the fundamental properties of the exact diode solutions. Lastly, the approximation is simple enough to be remembered and worked on almost any pocket calculator, so it has proven to be quite useful on the laboratory floor.
von Heimburg, Erna; Medbø, Jon Ingulf; Sandsund, Mariann; Reinertsen, Randi Eidsmo
2013-01-01
Firefighters must meet minimum physical demands. The Norwegian Labour Inspection Authority (NLIA) has approved a standardised treadmill walking test and 3 simple strength tests for smoke divers. The results of the Trondheim test were compared with those of the NLIA tests taking into account possible effects of age, experience level and gender. Four groups of participants took part in the tests: 19 young experienced firefighters, 24 senior male firefighters and inexperienced applicants, 12 male and 8 female. Oxygen uptake (VO2) at exhaustion rose linearly by the duration of the treadmill test. Time spent on the Trondheim test was closely related to performance time and peak VO2 on the treadmill test. Senior experienced firefighters did not perform better than equally fit young applicants. However, female applicants performed poorer on the Trondheim test than on the treadmill test. Performance on the Trondheim test was not closely related to muscle strength beyond a minimum. CONCLUSION. Firefighters completing the Trondheim test in under 19 min fit the requirements of the NLIA treadmill test. The Trondheim test can be used as an alternative to the NLIA tests for testing aerobic fitness but not for muscular strength. Women's result of the Trondheim test were poorer than the results of the NLIA treadmill test, probably because of their lower body mass.
Balion, Cynthia; Grey, Vijaylaxmi; Ismaila, Afisi; Blatz, Susan; Seidlitz, Wendy
2006-11-03
Point of care (POC) glucose meters are routinely used as a screening tool for hypoglycemia in a neonatal setting. Glucose meters however, lack the same accuracy as laboratory instruments for glucose measurement. In this study we investigated potential reasons for this inaccuracy and established a cut off value for confirmatory testing. In this prospective study, all patients in the neonatal intensive care unit who had a plasma glucose test ordered were eligible to participate. Demographic information, sample collection information (nine variables) and a recent hematocrit value were recorded for each sample. Glucose measurements were taken at the bedside on the glucose meter (RN PCx) as well as in the laboratory on both the glucose meter (LAB PCx) and the laboratory analyzer (PG). Data were analyzed by simple and mixed-effects regression analysis and by analysis of a receiver operator characteristics (ROC) curve. There were 475 samples analyzed from 132 patients. RN PCx values were higher than PG values (mean = 4.9%), while LAB PCx results were lower (mean = -5.2%) than PG values. Only 31% of the difference between RN PCx--PG and 46% of the difference for LAB PCx--PG could be accounted for by the variables tested. The largest proportion of variance between PCx and PG measurements was explained by hematocrit (about 30%) with a greater effect seen at glucose concentrations < or =4.0 mmol/L (< or =72 mg/dL)(48% and 40% for RN PCx and LAB PCx, respectively). The ROC analysis showed that for detection of all cases of hypoglycemia (PG < 2.6 mmol/L)(PG < 47 mg/dL) the PCx screening cut off value would need to be set at 3.8 mmol/L (68 mg/dL) requiring 20% of all samples to have confirmatory analysis by the laboratory method. The large difference between glucose results obtained by PCx glucose meter compared to the laboratory analyzer can be explained in part by hematocrit and low glucose concentration. These results emphasize that the glucose meter is useful only as a screening device for neonatal hypoglycemia and that a screening cut off value must be established.
Schmidt, Rodney A; Simmons, Kim; Grimm, Erin E; Middlebrooks, Michael; Changchien, Rosy
2006-11-01
Electronic document management systems (EDMSs) have the potential to improve the efficiency of anatomic pathology laboratories. We implemented a novel but simple EDMS for scanned documents as part of our laboratory information system (AP-LIS) and collected cost-benefit data with the intention of discerning the value of such a system in general and whether integration with the AP-LIS is advantageous. We found that the direct financial benefits are modest but the indirect and intangible benefits are large. Benefits of time savings and access to data particularly accrued to pathologists and residents (3.8 h/d saved for 26 pathologists and residents). Integrating the scanned document management system (SDMS) into the AP-LIS has major advantages in terms of workflow and overall simplicity. This simple, integrated SDMS is an excellent value in a practice like ours, and many of the benefits likely apply in other practice settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jensen, Richard P.; Stamp, Jason E.; Eddy, John P.
Many critical loads rely on simple backup generation to provide electricity in the event of a power outage. An Energy Surety Microgrid TM can protect against outages caused by single generator failures to improve reliability. An ESM will also provide a host of other benefits, including integration of renewable energy, fuel optimization, and maximizing the value of energy storage. The ESM concept includes a categorization for microgrid value proposi- tions, and quantifies how the investment can be justified during either grid-connected or utility outage conditions. In contrast with many approaches, the ESM approach explic- itly sets requirements based on unlikelymore » extreme conditions, including the need to protect against determined cyber adversaries. During the United States (US) Department of Defense (DOD)/Department of Energy (DOE) Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) effort, the ESM methodology was successfully used to develop the preliminary designs, which direct supported the contracting, construction, and testing for three military bases. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military installations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Melanie Johnson and Harold Sanborn of the U.S. Army Corps of Engineers Construc- tion Engineering Research Laboratory * Experts from the National Renewable Energy Laboratory, Idaho National Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory« less
Process for vitrification of contaminated sodium oxide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blair, H.T.; Mellinger, G.B.
1983-03-01
A glass composition was developed to accommodate 30 wt % sodium oxide and resist devitrification and leaching. An in-can melting process that is compatible with a comtaminated sodium calciner developed by Argonne National Laboratory was tested both on a laboratory and on an engineering scale and found to be viable. The Liquid Metal Fast Breeder Reactor experimental program continues to produce elemental sodium contaminated with radionuclides. This material is presently in temporary storage facilities because the current criterion will not permit alkali metals to be disposed of in shallow land burials. As a first step in treatment, Argonne National Laboratorymore » (ANL) has developed a calciner that will convert the sodium metal to an oxide. In work supported by the U.S. Department of Energy, Pacific Northwest Laboratory (PNL) is developing and demonstrating a process that is compatible with the calciner and facilities at ANL-West for incorporating sodium oxide into a glass. Glass, which normally contains sodium oxide, was chosen as the waste form because it is chemically durable and nondispersible. It is simple to produce, and the technology for incorporating nuclear wastes into glass is well developed.« less
Schofield, Pamela J.; Loftus, William F.; Kobza, Robert M.; Cook, Mark I.; Slone, Daniel H.
2010-01-01
The cold tolerance of two non-native cichlids (Hemichromis letourneuxi and Cichlasoma urophthalmus) that are established in south Florida was tested in the field and laboratory. In the laboratory, fishes were acclimated to two temperatures (24 and 28°C), and three salinities (0, 10, and 35 ppt). Two endpoints were identified: loss of equilibrium (11.5–13.7°C for C. urophthalmus; 10.8–12.5°C for H. letourneuxi), and death (9.5–11.1°C for C. urophthalmus; 9.1–13.3°C for H. letourneuxi). In the field, fishes were caged in several aquatic habitats during two winter cold snaps. Temperatures were lowest (4.0°C) in the shallow marsh, where no fish survived, and warmest in canals and solution-holes. Canals and ditches as shallow as 50 cm provided thermal refuges for these tropical fishes. Because of the effect on survival of different habitat types, simple predictions of ultimate geographic expansion by non-native fishes using latitude and thermal isoclines are insufficient for freshwater fishes.
Bonding to oxide ceramics—laboratory testing versus clinical outcome.
Kern, Matthias
2015-01-01
Despite a huge number of published laboratory bonding studies on dental oxide ceramics clinical long-term studies on resin bonded oxide ceramic restorations are rare. The purpose of this review is to present the best available clinical evidence for successful bonding of dental oxide ceramic restorations. Clinical trials with resin-bonded restorations that had no or only limited mechanical retention and were made from alumina or zirconia ceramic were identified using an electronic search in PubMed database. Overall 10 publications with clinical trials could be identified. Their clinical outcome was compared with that laboratory bond strength studies. Clinical data provide strong evidence that air-abrasion at a moderate pressure in combination with using phosphate monomer containing primers and/or luting resins provide long-term durable bonding to glass-infiltrated alumina and zirconia ceramic under the humid and stressful oral conditions. As simple and clinically reliable bonding methods to oxide ceramics exist, the rationale for development of alternative bonding methods might be reconsidered especially when these methods are more time consuming or require rather complicated and/or technique sensitive procedures. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
The future of computer-aided sperm analysis
Mortimer, Sharon T; van der Horst, Gerhard; Mortimer, David
2015-01-01
Computer-aided sperm analysis (CASA) technology was developed in the late 1980s for analyzing sperm movement characteristics or kinematics and has been highly successful in enabling this field of research. CASA has also been used with great success for measuring semen characteristics such as sperm concentration and proportions of progressive motility in many animal species, including wide application in domesticated animal production laboratories and reproductive toxicology. However, attempts to use CASA for human clinical semen analysis have largely met with poor success due to the inherent difficulties presented by many human semen samples caused by sperm clumping and heavy background debris that, until now, have precluded accurate digital image analysis. The authors review the improved capabilities of two modern CASA platforms (Hamilton Thorne CASA-II and Microptic SCA6) and consider their current and future applications with particular reference to directing our focus towards using this technology to assess functional rather than simple descriptive characteristics of spermatozoa. Specific requirements for validating CASA technology as a semi-automated system for human semen analysis are also provided, with particular reference to the accuracy and uncertainty of measurement expected of a robust medical laboratory test for implementation in clinical laboratories operating according to modern accreditation standards. PMID:25926614
Mina, Ashraf; Favaloro, Emmanuel J; Koutts, Jerry
2008-01-01
In response to increasingly complex demands in terms of productivity and budgets, there is a critical need to avoid mistakes during instrument selection that will be financially costly, and adversely affect customers, staff, productivity and test turnaround time. As there is no "one size fits all", guidelines must be appropriate to permit informed decision making. A Medline search was conducted to assess background knowledge in this area, using the terms "laboratory instrument selection" and "laboratory instrument evaluation". Searches returned over 800 articles, of which only seven were directly related to the topic of the search, with most outdated, and suggesting a paucity of appropriate information. Additional resources used included the American Association of Clinical Chemistry (AACC) website and the Internet. Appropriate criteria for instrument selection were established in the current report based on subjective and objective (technical) evaluations. Additionally, a sound and simple financial approach is also suggested to help in making informed decisions and avoid costly mistakes. We propose that such a process as outlined in our report will protect laboratories from making costly and avoidable mistakes in the acquisition of major equipment.
NASA Astrophysics Data System (ADS)
Main, I. G.; Bell, A. F.; Greenhough, J.; Heap, M. J.; Meredith, P. G.
2010-12-01
The nucleation processes that ultimately lead to earthquakes, volcanic eruptions, rock bursts in mines, and landslides from cliff slopes are likely to be controlled at some scale by brittle failure of the Earth’s crust. In laboratory brittle deformation experiments geophysical signals commonly exhibit an accelerating trend prior to dynamic failure. Similar signals have been observed prior to volcanic eruptions, including volcano-tectonic earthquake event and moment release rates. Despite a large amount of effort in the search, no such statistically robust systematic trend is found prior to natural earthquakes. Here we describe the results of a suite of laboratory tests on Mount Etna Basalt and other rocks to examine the nature of the non-linear scaling from laboratory to field conditions, notably using laboratory ‘creep’ tests to reduce the boundary strain rate to conditions more similar to those in the field. Seismic event rate, seismic moment release rate and rate of porosity change show a classic ‘bathtub’ graph that can be derived from a simple damage model based on separate transient and accelerating sub-critical crack growth mechanisms, resulting from separate processes of negative and positive feedback in the population dynamics. The signals exhibit clear precursors based on formal statistical model tests using maximum likelihood techniques with Poisson errors. After correcting for the finite loading time of the signal, the results show a transient creep rate that decays as a classic Omori law for earthquake aftershocks, and remarkably with an exponent near unity, as commonly observed for natural earthquake sequences. The accelerating trend follows an inverse power law when fitted in retrospect, i.e. with prior knowledge of the failure time. In contrast the strain measured on the sample boundary shows a less obvious but still accelerating signal that is often absent altogether in natural strain data prior to volcanic eruptions. To test the forecasting power of such constitutive rules in prospective mode, we examine the forecast quality of several synthetic trials, by adding representative statistical fluctuations, due to finite real-time sampling effects, to an underlying accelerating trend. Metrics of forecast quality change systematically and dramatically with time. In particular the model accuracy increases, and the forecast bias decreases, as the failure time approaches.
Mata, Verónica Elizabeth; Passos, Sonia Regina Lambert; Hökerberg, Yara Hahr Marques; Berardinelli, Guilherme Miguéis; Dos Santos, Maria Angelica Borges; Fukuoka, Levy Vilas Boas; Maciel, Anna Carolina Fontoura Seixas Rangel; Dos Santos Rodrigues, Cintia Damasceno; da Silva Santos, Aline; de Vasconcellos Carvalhaes de Oliveira, Raquel
2017-08-29
Rapid immunochromatographic tests (ICT) for dengue non-structural protein 1 (NS1) have shown good performance for diagnosing acute-phase dengue in serum in laboratory settings, but rarely have been assessed in whole blood and at point of care (POC). This study compare the accuracy and inter- and intra-observer reliability of the NS1 Bioeasy™ ICT in whole blood at POC versus serum in the laboratory, during a DENV-1 epidemic. Cross-sectional study involving 144 adults spontaneously demanding care in an emergency department within 4 days of onset of acute febrile illness. Accuracy of NS1 Bioeasy™ ICT was compared in whole blood and serum, both at 15 and 30 min, blinded to the reference RT-PCR or NS1 ELISA. Non-dengue patients were also tested for Zika virus with RT-PCR. Reliability of whole blood and serum readings by the same or different observers was measured by simple kappa (95% CI). At 15 min, sensitivity (Sn) of NS1 Bioeasy™ ICT in whole blood/POC was 76.7% (95% CI: 68.0-84.1) and specificity (Sp) was 87.0% (95% CI: 66.4-97.2). Sn in serum/laboratory was 82% (95% CI: 74.1-88.6) and Sp 100% (95% CI: 85.8-100). Positive likelihood ratio was 5.9 (95% CI: 2.0-17.0) for whole blood/POC and 19.8 (95% CI: 2.9-135.1) for serum/laboratory. Reliability of matched readings of whole blood/POC and serum/laboratory by the same observer (k = 0.83, 95% CI: 0.74-0.93) or different observers (k = 0.81, 95% CI: 0.72-0.92) was almost perfect, with higher discordant levels in the absence of dengue. Results did not differ statistically at 5%. NS1 Bioeasy™ ICT in DENV-1 epidemics is a potentially confirmatory test. Invalid results at 15 min should be reread at 30 min. To optimize impact of implementing ICT in the management of false-negatives it should be incorporated into an algorithm according to setting and available specimen. UTN U1111-1145-9451 .
Predictive modelling of flow in a two-dimensional intermediate-scale, heterogeneous porous media
Barth, Gilbert R.; Hill, M.C.; Illangasekare, T.H.; Rajaram, H.
2000-01-01
To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.To better understand the role of sedimentary structures in flow through porous media, and to determine how small-scale laboratory-measured values of hydraulic conductivity relate to in situ values this work deterministically examines flow through simple, artificial structures constructed for a series of intermediate-scale (10 m long), two-dimensional, heterogeneous, laboratory experiments. Nonlinear regression was used to determine optimal values of in situ hydraulic conductivity, which were compared to laboratory-measured values. Despite explicit numerical representation of the heterogeneity, the optimized values were generally greater than the laboratory-measured values. Discrepancies between measured and optimal values varied depending on the sand sieve size, but their contribution to error in the predicted flow was fairly consistent for all sands. Results indicate that, even under these controlled circumstances, laboratory-measured values of hydraulic conductivity need to be applied to models cautiously.
Synthesis and Characterization of Silver Nanoparticles for an Undergraduate Laboratory
ERIC Educational Resources Information Center
Orbaek, Alvin W.; McHale, Mary M.; Barron, Andrew R.
2015-01-01
The aim of this simple, quick, and safe laboratory exercise is to provide undergraduate students an introduction to nanotechnology using nanoparticle (NP) synthesis. Students are provided two procedures that allow for the synthesis of different yet controlled sizes of silver NPs. After preparing the NPs, the students perform UV-visible…
Experimenting with Impacts in a Conceptual Physics or Descriptive Astronomy Laboratory
ERIC Educational Resources Information Center
LoPresto, Michael C.
2016-01-01
What follows is a description of the procedure for and results of a simple experiment on the formation of impact craters designed for the laboratory portions of lower mathematical-level general education science courses such as conceptual physics or descriptive astronomy. The experiment provides necessary experience with data collection and…
A Simple, Low-Cost, Data-Logging Pendulum Built from a Computer Mouse
ERIC Educational Resources Information Center
Gintautas, Vadas; Hubler, Alfred
2009-01-01
Lessons and homework problems involving a pendulum are often a big part of introductory physics classes and laboratory courses from high school to undergraduate levels. Although laboratory equipment for pendulum experiments is commercially available, it is often expensive and may not be affordable for teachers on fixed budgets, particularly in…
A Modified Bagnold-Type Wind Tunnel for Laboratory Use
ERIC Educational Resources Information Center
Logan, Alan
1975-01-01
Using the basic Bagnold design, a relatively inexpensive suction-type wind tunnel can be constructed for laboratory demonstration of sand-grain movement, ripple development, and other eolian processes. Its simple design provides no workshop problems and it can be made for a total cost in materials of approximately $225. (Author/CP)
ERIC Educational Resources Information Center
Ibanez, Jorge G.; Mena-Brito, Rodrigo; Fregoso-Infante, Arturo
2005-01-01
A microscale experiment in which the simultaneous oxidation of an organic compound and the reduction of a metal ion are photocatalytically performed in an aqueous slurry containing TiO[subscript 2] irradiated with UV light. This experiment can be performed in the laboratory session with simple chemicals and equipments.
ERIC Educational Resources Information Center
Clausen, Thomas P.
2011-01-01
The Fisher esterification reaction is ideally suited for the undergraduate organic laboratory because it is easy to carry out and often involves a suitable introduction to basic laboratory techniques including extraction, distillation, and simple spectroscopic (IR and NMR) analyses. Here, a Fisher esterification reaction is described in which the…
Mother Earth Chemistry: A Laboratory Course for Nonmajors.
ERIC Educational Resources Information Center
Roberts, J. L.; And Others
1996-01-01
Describes a laboratory course that introduces students to chemistry using examples commonly encountered in the supermarket and on the dinner table. Acquaints students with simple chemical tasks that can be practiced at home, including the making of wine, ale, soap, cheese, and yogurt, and introduces them to the small-scale production of…
A DNA Melting Exercise for a Large Laboratory Class
ERIC Educational Resources Information Center
Levine, Lauren A.; Junker, Matthew; Stark, Myranda; Greenleaf, Dustin
2015-01-01
A simple and economical experimental setup is described that enables multiple individuals or groups within a laboratory class to measure the thermal melting of double stranded DNA simultaneously. The setup utilizes a basic spectrophotometer capable of measuring absorbance at 260 nm, UV plastic cuvettes, and a stirring hot plate. Students measure…
Introducing Human Population Biology through an Easy Laboratory Exercise on Mitochondrial DNA
ERIC Educational Resources Information Center
Pardinas, Antonio F.; Dopico, Eduardo; Roca, Agustin; Garcia-Vazquez, Eva; Lopez, Belen
2010-01-01
This article describes an easy and cheap laboratory exercise for students to discover their own mitochondrial haplogroup. Students use buccal swabs to obtain mucosa cells as noninvasive tissue samples, extract DNA, and with a simple polymerase chain reaction-restriction fragment length polymorphism analysis they can obtain DNA fragments of…
ERIC Educational Resources Information Center
Marchetti, Fabio; Di Nicola, Corrado; Pettinari, Riccardo; Timokhin, Ivan; Pettinari, Claudio
2012-01-01
A simple synthesis is proposed from inexpensive reactants of a copper(I) derivative that exhibits strong photoluminescence and, in the crystalline form, exhibits strong triboluminescence. This laboratory provides an opportunity for introducing students to the phenomenon of triboluminescence. (Contains 1 scheme and 4 figures.)
ERIC Educational Resources Information Center
Klotz, Elsbeth; Doyle, Robert; Gross, Erin; Mattson, Bruce
2011-01-01
A simple, inexpensive, and environmentally friendly undergraduate laboratory experiment is described in which students use visible spectroscopy to determine a numerical value for an equilibrium constant, K[subscript c]. The experiment correlates well with the lecture topic of equilibrium even though the subject of the study is an acid-base…
Easy Ways to Promote Inquiry in a Laboratory Course: The Power of Student Questions
ERIC Educational Resources Information Center
Polacek, Kelly Myer; Keeling, Elena Levine
2005-01-01
To teach students to think like scientists, the authors modified their laboratory course to include regular opportunities for student practice of inquiry and the scientific process. Their techniques are simple; they can be implemented without rewriting lab manuals, require little additional grading beyond typical lab reports, and are applicable…
Forest Products Laboratory natural finish
J. M. Black; D. F. Laughnan; E. A. Mraz
1979-01-01
A simple and durable exterior natural finish developed at the Forest Products Laboratory is described. The finish is classified as a semi-transparent oil-base penetrating stain that effectively retains much of the natural grain and texture of wood when exposed to the weather. The directions for preparation are included as are the recommendations for application to both...
ERIC Educational Resources Information Center
Richardson, W. S., III; Burns, L.
1988-01-01
Describes a simple high-performance liquid chromatography experiment for undergraduate biochemistry laboratories. The experiment illustrates the separation of polypeptides by a step gradient elution using a single pump instrument with no gradient attachments. Discusses instrumentation, analysis, a sample preparation, and results. (CW)
Implementation of Artificial Intelligence Assessment in Engineering Laboratory Education
ERIC Educational Resources Information Center
Samarakou, Maria; Fylladitakis, Emmanouil D.; Prentakis, Pantelis; Athineos, Spyros
2014-01-01
In laboratory courses, the assessment of exercises and assignments typically is treated as a simple, quantifiable approach. This approach however rarely includes qualitative factors, especially if the grading is being automatically performed by the system, and provides little to no feedback for the students to reflect on their work. The role of…
2012-04-06
Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn screening laboratories. The recommended practices address the benefits of using a quality management system approach, factors to consider before introducing new tests, establishment and verification of test performance specifications, the total laboratory testing process (which consists of the preanalytic, analytic, and postanalytic phases), confidentiality of patient information and test results, and personnel qualifications and responsibilities for laboratory testing for inherited metabolic diseases. These recommendations are intended for laboratories that perform biochemical genetic testing to improve the quality of laboratory services and for newborn screening laboratories to ensure the quality of laboratory practices for inherited metabolic disorders. These recommendations also are intended as a resource for medical and public health professionals who evaluate laboratory practices, for users of laboratory services to facilitate their collaboration with newborn screening systems and use of biochemical genetic tests, and for standard-setting organizations and professional societies in developing future laboratory quality standards and practice recommendations. This report complements Good Laboratory Practices for Molecular Genetic Testing for Heritable Diseases and Conditions (CDC. Good laboratory practices for molecular genetic testing for heritable diseases and conditions. MMWR 2009;58 [No. RR-6]) to provide guidance for ensuring and improving the quality of genetic laboratory services and public health outcomes. Future recommendations for additional areas of genetic testing will be considered on the basis of continued monitoring and evaluation of laboratory practices, technology advancements, and the development of laboratory standards and guidelines.
NASA Astrophysics Data System (ADS)
McNamara, Laura A.; Berg, Leif; Butler, Karin; Klein, Laura
2017-05-01
Even as remote sensing technology has advanced in leaps and bounds over the past decade, the remote sensing community lacks interfaces and interaction models that facilitate effective human operation of our sensor platforms. Interfaces that make great sense to electrical engineers and flight test crews can be anxiety-inducing to operational users who lack professional experience in the design and testing of sophisticated remote sensing platforms. In this paper, we reflect on an 18-month collaboration which our Sandia National Laboratory research team partnered with an industry software team to identify and fix critical issues in a widely-used sensor interface. Drawing on basic principles from cognitive and perceptual psychology and interaction design, we provide simple, easily learned guidance for minimizing common barriers to system learnability, memorability, and user engagement.
Household Pasteurization of Drinking-water: The Chulli Water-treatment System
Islam, Mohammad Fakhrul
2006-01-01
A simple flow-through system has been developed which makes use of wasted heat generated in traditional clay ovens (chullis) to pasteurize surface water. A hollow aluminium coil is built into the clay chulli, and water is passed through the coil during normal cooking events. By adjusting the flow rate, effluent temperature can be maintained at approximately 70 °C. Laboratory testing, along with over 400 field tests on chulli systems deployed in six pilot villages, showed that the treatment completely inactivated thermotolerant coliforms. The chulli system produces up to 90 litres per day of treated water at the household level, without any additional time or fuel requirement. The technology has been developed to provide a safe alternative source of drinking-water in arsenic-contaminated areas, but can also have wide application wherever people consume microbiologically-contaminated water. PMID:17366777
Household pasteurization of drinking-water: the chulli water-treatment system.
Islam, Mohammad Fakhrul; Johnston, Richard B
2006-09-01
A simple flow-through system has been developed which makes use of wasted heat generated in traditional clay ovens (chullis) to pasteurize surface water. A hollow aluminium coil is built into the clay chulli, and water is passed through the coil during normal cooking events. By adjusting the flow rate, effluent temperature can be maintained at approximately 70 degrees C. Laboratory testing, along with over 400 field tests on chulli systems deployed in six pilot villages, showed that the treatment completely inactivated thermotolerant coliforms. The chulli system produces up to 90 litres per day of treated water at the household level, without any additional time or fuel requirement. The technology has been developed to provide a safe alternative source of drinking-water in arsenic-contaminated areas, but can also have wide application wherever people consume microbiologically-contaminated water.
NASA Technical Reports Server (NTRS)
Havelund, Klaus; Smith, Margaret H.; Barringer, Howard; Groce, Alex
2012-01-01
LogScope is a software package for analyzing log files. The intended use is for offline post-processing of such logs, after the execution of the system under test. LogScope can, however, in principle, also be used to monitor systems online during their execution. Logs are checked against requirements formulated as monitors expressed in a rule-based specification language. This language has similarities to a state machine language, but is more expressive, for example, in its handling of data parameters. The specification language is user friendly, simple, and yet expressive enough for many practical scenarios. The LogScope software was initially developed to specifically assist in testing JPL s Mars Science Laboratory (MSL) flight software, but it is very generic in nature and can be applied to any application that produces some form of logging information (which almost any software does).
Study of the collector/heat pipe cooled externally configured thermionic diode
NASA Technical Reports Server (NTRS)
1973-01-01
A collector/heat pipe cooled, externally configured (heated) thermionic diode module was designed for use in a laboratory test to demonstrate the applicability of this concept as the fuel element/converter module of an in-core thermionic electric power source. During the course of the program, this module evolved from a simple experimental mock-up into an advanced unit which was more reactor prototypical. Detailed analysis of all diode components led to their engineering design, fabrication, and assembly, with the exception of the collector/heat pipe. While several designs of high power annular wicked heat pipes were fabricated and tested, each exhibited unexpected performance difficulties. It was concluded that the basic cause of these problems was the formation of crud which interfered with the liquid flow in the annular passage of the evaporator region.
Versatile electrophoresis-based self-test platform.
Guijt, Rosanne M
2015-03-01
Lab on a Chip technology offers the possibility to extract chemical information from a complex sample in a simple, automated way without the need for a laboratory setting. In the health care sector, this chemical information could be used as a diagnostic tool for example to inform dosing. In this issue, the research underpinning a family of electrophoresis-based point-of-care devices for self-testing of ionic analytes in various sample matrices is described [Electrophoresis 2015, 36, 712-721.]. Hardware, software, and methodological chances made to improve the overall analytical performance in terms of accuracy, precision, detection limit, and reliability are discussed. In addition to the main focus of lithium monitoring, new applications including the use of the platform for veterinary purposes, sodium, and for creatinine measurements are included. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Toward Improvements in Inter-laboratory Calibration of Argon Isotope Measurements
NASA Astrophysics Data System (ADS)
Hemming, S. R.; Deino, A. L.; Heizler, M. T.; Hodges, K. V.; McIntosh, W. C.; Renne, P. R.; Swisher, C. C., III; Turrin, B. D.; Van Soest, M. C.
2015-12-01
It is important to continue to develop strategies to improve our ability to compare results between laboratories chronometers. The U-Pb community has significantly reduced inter-laboratory biases with the application of a community tracer solution and the distribution of synthetic zircon solutions. Inevitably sample selection and processing and even biases in interpretations will still lead to some disagreements in the assignment of ages. Accordingly natural samples that are shared will be important for achievement of the highest levels of agreement. Analogous improvements in quality and inter-laboratory agreement of analytical aspects of Ar-Ar can be achieved through development of synthetic age standards in gas canisters with multiple pipettes to deliver various controlled amounts of argon to the mass spectrometer. A preliminary proof-of concept comes from the inter-laboratory calibration experiment for the 40Ar/39Ar community. This portable Argon Pipette Intercalibration System (APIS) consists of three 2.7 L canisters each equipped with three pipettes of 0.1, 0.2 and 0.4 cc volumes. The currently traveling APIS has the three canisters filled with air and 40Ar*/39Ar of 1.73 and canister 2 has a 40Ar*/39Ar of 40.98 (~ Alder Creek and Fish Canyon in the same irradiation). With these pipettes it is possible to combine them to provide 0.1, 0.2, 0.3 (0.1+0.2), 0.4, 0.5 (0.1+0.4), 0.6 (0.2+0.4), and 0.7 (0.1+0.2+0.4) cc. The configuration allows a simple test for inter-laboratory biases and for volume/pressure dependent mass fractionation on the measured ratios for a gas with a single argon isotope composition. Although not yet tested, it is also possible to mix gas from any one of the three canisters in proportions of these increments, allowing even more tightly controlled calibration of measurements. We suggest that ultimately each EARTHTIME lab should be equipped with such a system permanently, with a community plan for a traveling system to periodically repeat the inter-calibration tests. The composition(s) of such systems may not be the same for each lab, depending on the requirements of equipment and main age ranges targeted. But with a relatively small number of end member compositions it should be possible to greatly improve the calibration capability of the community.
Isaiah, Ibeh Nnana; Nche, Bikwe Thomas; Nwagu, Ibeh Georgina; Nwagu, Ibeh Isaiah
2011-01-01
Background: the occurrence of the different types of Extended spectrum beta Lactamase producing Escherichia coli with the, Sulphurhydryl variable, Temonera and the Cefotaximase have been on the rise Aim: The study was to determine the prevalence of extended spectrum beta lactamase gene resistance across the clinical isolates of hospitalized patients. Materials and Method: Three hundred and fifty isolates of Escherichia coli were received from different clinical specimens. The susceptibility profile of the isolates against 10 different antibiotics was examined, the MICs (Minimum Inhibitory Concentration) for ceftazidime were also determined using micro-broth dilution assay. Isolates showing MIC ≥ 6 μg/ml for ceftazidime were screened for ESBL (PCT)phenotypic confirmatory test and subjected to PCR (polymerase chain reaction) to further. Results: By disk diffusion test, there was resistance to ceftazidime and cefotaxime were 180(51.4%) and 120 (34.2%) respectively. However, all strains were susceptible to imipenem. 250 isolates showed MICs≥ 6 μg/ml for ceftazidime of which 180 (72%) were positive for extended spectrum beta lactamase. The prevalence of Sulphurhydryl variable, Temonera and the Cefotaximase among these isolates were 17.1%, 6.6% and 17%, respectively. Conclusion: For the identification of extended spectrum beta lactamase producing isolates it is recommended that clinical laboratories adopt simple test based on Cinical laboratory standard institute recommendation for confirming extended spectrum beta lactamase production in enterobacteriacea species. PMID:22363078
Acestor, Nathalie; Goett, Jane; Lee, Arthur; Herrick, Tara M; Engelbrecht, Susheela M; Harner-Jay, Claudia M; Howell, Bonnie J; Weigl, Bernhard H
2016-01-01
In recent years, an increasing amount of literature is emerging on candidate urine and blood-based biomarkers associated with incidence and severity of preeclampsia (PE) in pregnant women. While enthusiasm on the usefulness of several of these markers in predicting PE is evolving, essentially all work so far has focused on the needs of high-resource settings and high-income countries, resulting primarily in multi-parameter laboratory assays based on proteomic and metabolomics analysis techniques. These highly complex methods, however, require laboratory capabilities that are rarely available or affordable in low-resource settings (LRS). The importance of quantifying maternal and perinatal risks and identifying which pregnancies can be safely prolonged is also much greater in LRS, where intensive care facilities that can rapidly respond to PE-related health threats for women and infants are limited. For these reasons, simple, low cost, sensitive, and specific point-of-care (POC) tests are needed that can be performed by antenatal health care providers in LRS and that can facilitate decisions about detection and management of PE. Our study aims to provide a comprehensive systematic review of current and emerging blood and urine biomarkers for PE, not only on the basis of their clinical performance, but also of their suitability to be used in LRS-compatible test formats, such as lateral flow and other variants of POC rapid assays.
A compact field fluorometer and its application to dye tracing in karst environments
NASA Astrophysics Data System (ADS)
Poulain, Amaël; Rochez, Gaëtan; Van Roy, Jean-Pierre; Dewaide, Lorraine; Hallet, Vincent; De Sadelaer, Geert
2017-08-01
Dye tracing is a classic technique in hydrogeology to investigate surface-water or groundwater flow characteristics, and it is useful for many applications including natural or industrial issues. The Fluo-Green field fluorometer has been successfully tested in a karst environment and is specifically suitable for in-cave karst water monitoring. Karst research often uses dyes to obtain information about groundwater flow in unexplored cave passages. The compact device, alternatively named Fluo-G, meets the requirements of cave media: small (10 × 16 × 21 cm), lightweight (0.75 kg without ballast) and simple in conception. It is easy for cavers to set up and handle compared to other sampling methods. The fluorometer records uranine, turbidity and temperature with a user-defined time-step (1 min - 1 day). Very low energy consumption allows 9,000 measurements with six AA batteries. The device was calibrated and tested in the laboratory and in field conditions in Belgian karst systems. Results are in good fit with other sampling methods: in-situ fluorometers and automatic water sampling plus laboratory analysis. Recording high quality data (breakthrough curves) in karst with in-cave monitoring is valuable to improve knowledge of karst systems. Many hydrological and hydrogeological applications can benefit from such a low-cost and compact device, and finding the best compromise between resources and quality data is essential. Several improvements are possible but preliminary field tests are very promising.
Study on shear properties of coral sand under cyclic simple shear condition
NASA Astrophysics Data System (ADS)
Ji, Wendong; Zhang, Yuting; Jin, Yafei
2018-05-01
In recent years, the ocean development in our country urgently needs to be accelerated. The construction of artificial coral reefs has become an important development direction. In this paper, experimental studies of simple shear and cyclic simple shear of coral sand are carried out, and the shear properties and particle breakage of coral sand are analyzed. The results show that the coral sand samples show an overall shear failure in the simple shear test, which is more accurate and effective for studying the particle breakage. The shear displacement corresponding to the peak shear stress of the simple shear test is significantly larger than that corresponding to the peak shear stress of the direct shear test. The degree of particle breakage caused by the simple shear test is significantly related to the normal stress level. The particle breakage of coral sand after the cyclic simple shear test obviously increases compared with that of the simple shear test, and universal particle breakage occurs within the whole particle size range. The increasing of the cycle-index under cyclic simple shear test results in continuous compacting of the sample, so that the envelope curve of peak shearing force increases with the accumulated shear displacement.
The Mile Deep Muon Detector at Sanford Underground Laboratory
NASA Astrophysics Data System (ADS)
McMahan, Margaret; Gabriel, Steve
2012-03-01
For educating students and teachers about basic nuclear and particle physics, you can't go wrong with cosmic rays muons as a cheap and reliable source of data. A simple and relatively inexpensive detector gives a myriad of possibilities to cover core material in physical science, chemistry, physics, and statistics and gives students opportunities to design their own investigations. At Sanford Underground Laboratory at Homestake, in Lead, SD, cosmic ray muon detectors are being used to answer the first question always asked by any visitor to the facility, ``Why are you building the lab a mile underground'' A conventional Quarknet-style detector is available in the education facility on the surface, with a much larger companion detector, the Mile Deep Muon Detector, set up 4850 feet below the surface. Using the Quarknet data acquisition board, the data will be made available to students and teachers through the Cosmic Ray E-lab website. The detector was tested and installed as part of a summer program for students beginning their first or second year of college.
Damjan, Igor; Cvijanović, Milan; Erak, Marko
2010-01-01
Polyneuropathies or peripheral neuropathies present a dysfunction or disease of larger number of peripheral nerves or their dysfunction. Considering their morbidity - mortality characteristics they present an important aspect in daily clinical practice. One particular polyneuropathy that deserves special review is chronic inflammatory demyelinating polyneuropathy, which, due to its clinical-laboratory presentation, does not include the group of "simple" neuropathies, thus requiring further examinations. Neurophysiological testing should be performed using the protocol for neuropathy examinations. Neurophysiological examination, during the electroneurographic examination, shows neurographic parameters referring to polyneuropatic demyelinating type of lesion, while the electromyographic finding records the presence of neuropathic lesions (denervation activity, great action potentials with a reduced sample). A 54-year-old patient was diagnosed to have a "complicated" demyelinating polyneuropathy according to the clinical-laboratory findings and electromyographic examination. Exclusion criteria, targeted diagnostic examinations, considering the mentioned peripheral neuropathies, pointed to acute inflammatory demyelinating polyneuropathy. However, the chronic inflammatory demyelinating polyneuropathy was finally differentiated during the clinical and electromyographic monitoring.
UV Catalysis, Cyanotype Photography, and Sunscreens
NASA Astrophysics Data System (ADS)
Lawrence, Glen D.; Fishelson, Stuart
1999-09-01
This laboratory experiment is intended for a chemistry course for non-science majors. The experiment utilizes one of the earliest photographic processes, the cyanotype process, to demonstrate UV catalysis of chemical reactions. In addition to making photographic prints from negatives, the process can be used to test the effectiveness of sunscreens and the relative efficacy of the SPF (sun protection factor) rating of sunscreens. This is an inexpensive process, requiring solutions of ammonium ferric citrate and potassium ferricyanide, with options to use hydrogen peroxide and ammonium hydroxide solutions. Students can prepare their own UV-sensitized paper with the indicated chemicals and watch the photographic image appear as it is exposed to sunlight or fluorescent UV lamps in a light box designed for use in this experiment. The laboratory experiment should stimulate discussion of UV catalysis, photographic processes and photochemistry, sunscreens, and UV damage to biological organisms. The chemicals used are relatively nontoxic, and the procedure is simple enough to be used by groups of diverse ages and abilities.
Experimental Evaluation of the Free Piston Engine - Linear Alternator (FPLA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leick, Michael T.; Moses, Ronald W.
2015-03-01
This report describes the experimental evaluation of a prototype free piston engine - linear alternator (FPLA) system developed at Sandia National Laboratories. The opposed piston design wa developed to investigate its potential for use in hybrid electric vehicles (HEVs). The system is mechanically simple with two - stroke uniflow scavenging for gas exchange and timed port fuel injection for fuel delivery, i.e. no complex valving. Electrical power is extracted from piston motion through linear alternators wh ich also provide a means for passive piston synchronization through electromagnetic coupling. In an HEV application, this electrical power would be used to chargemore » the batteries. The engine - alternator system was designed, assembled and operated over a 2 - year period at Sandia National Laboratories in Livermore, CA. This report primarily contains a description of the as - built system, modifications to the system to enable better performance, and experimental results from start - up, motoring, and hydrogen combus tion tests.« less
Comparison of the dye method with the thermocouple psychrometer for measuring leaf water potentials.
Knipling, E B; Kramer, P J
1967-10-01
The dye method for measuring water potential was examined and compared with the thermocouple psychrometer method in order to evaluate its usefulness for measuring leaf water potentials of forest trees and common laboratory plants. Psychrometer measurements are assumed to represent the true leaf water potentials. Because of the contamination of test solutions by cell sap and leaf surface residues, dye method values of most species varied about 1 to 5 bars from psychrometer values over the leaf water potential range of 0 to -30 bars. The dye method is useful for measuring changes and relative values in leaf potential. Because of species differences in the relationships of dye method values to true leaf water potentials, dye method values should be interpreted with caution when comparing different species or the same species growing in widely different environments. Despite its limitations the dye method has a usefulness to many workers because it is simple, requires no elaborate equipment, and can be used in both the laboratory and field.
An Improved Green's Function for Ion Beam Transport
NASA Technical Reports Server (NTRS)
Tweed, J.; Wilson, J. W.; Tripathi, R. K.
2003-01-01
Ion beam transport theory allows testing of material transmission properties in the laboratory environment generated by particle accelerators. This is a necessary step in materials development and evaluation for space use. The approximations used in solving the Boltzmann transport equation for the space setting are often not sufficient for laboratory work and those issues are the main emphasis of the present work. In consequence, an analytic solution of the linear Boltzmann equation is pursued in the form of a Green's function allowing flexibility in application to a broad range of boundary value problems. It has been established that simple solutions can be found for the high charge and energy (HZE) by ignoring nuclear energy downshifts and dispersion. Such solutions were found to be supported by experimental evidence with HZE ion beams when multiple scattering was added. Lacking from the prior solutions were range and energy straggling and energy downshift with dispersion associated with nuclear events. Recently, we have found global solutions including these effects providing a broader class of HZE ion solutions.
Timeliness “at a glance”: assessing the turnaround time through the six sigma metrics.
Ialongo, Cristiano; Bernardini, Sergio
2016-01-01
Almost thirty years of systematic analysis have proven the turnaround time to be a fundamental dimension for the clinical laboratory. Several indicators are to date available to assess and report quality with respect to timeliness, but they sometimes lack the communicative immediacy and accuracy. The six sigma is a paradigm developed within the industrial domain for assessing quality and addressing goal and issues. The sigma level computed through the Z-score method is a simple and straightforward tool which delivers quality by a universal dimensionless scale and allows to handle non-normal data. Herein we report our preliminary experience in using the sigma level to assess the change in urgent (STAT) test turnaround time due to the implementation of total automation. We found that the Z-score method is a valuable and easy to use method for assessing and communicating the quality level of laboratory timeliness, providing a good correspondence with the actual change in efficiency which was retrospectively observed.
Advances in Developing HIV-1 Viral Load Assays for Resource-Limited Settings
Wang, ShuQi; Xu, Feng; Demirci, Utkan
2010-01-01
Commercial HIV-1 RNA viral load assays have been routinely used in developed countries to monitor antiretroviral treatment (ART). However, these assays require expensive equipment and reagents, well-trained operators, and established laboratory infrastructure. These requirements restrict their use in resource-limited settings where people are most afflicted with the HIV-1 epidemic. Inexpensive alternatives such as the Ultrasensitive p24 assay, the Reverse Transcriptase (RT) assay and in-house reverse transcription quantitative polymerase chain reaction (RT-qPCR) have been developed. However, they are still time-consuming, technologically complex and inappropriate for decentralized laboratories as point-of-care (POC) tests. Recent advances in microfluidics and nanotechnology offer new strategies to develop low-cost, rapid, robust and simple HIV-1 viral load monitoring systems. We review state-of-the-art technologies used for HIV-1 viral load monitoring in both developed and developing settings. Emerging approaches based on microfluidics and nanotechnology, which have potential to be integrated into POC HIV-1 viral load assays, are also discussed. PMID:20600784
Aldana Marcos, H J; Ferrari, C C; Benitez, I; Affanni, J M
1996-12-01
This paper reports the standardization of methods used for processing and embedding various vertebrate brains of different size in paraffin. Other technical details developed for avoiding frequent difficulties arising during laboratory routine are also reported. Some modifications of the Nissl and Klüver-Barrera staining methods are proposed. These modifications include: 1) a Nissl stain solution with a rapid and efficient action with easier differentiation; 2) the use of a cheap microwave oven for the Klüver-Barrera stain. These procedures have the advantage of permitting Nissl and Klüver-Barrera staining of nervous tissue in about five and fifteen minutes respectively. The proposed procedures have been tested in brains obtained from fish, amphibians, reptiles and mammals of different body sizes. They are the result of our long experience in preparing slides for comparative studies. Serial sections of excellent quality were regularly obtained in all the specimens studied. These standardized methods, being simple and quick, are recommended for routine use in neurobiological laboratories.
ERIC Educational Resources Information Center
Okulu, Hasan Zuhtu; Oguz-Unver, Ayse
2015-01-01
From the perspective of teaching, the huge natural laboratory that astronomy provides constitutes the most prominent connection between astronomy and other branches of science. The purpose of this research was to provide educators with activities of observation using simple materials that were developed to facilitate the teaching of basic concepts…
ERIC Educational Resources Information Center
Kuntzleman, Thomas S.; Jacobson, Erik C.
2016-01-01
A very simple protocol for teaching Beer's Law and absorption spectrophotometry using a smart phone is described. Materials commonly found in high school chemistry laboratories or even around the house may be used. Data collection and analysis is quick and easy. Despite the simple nature of the experiment, excellent results can be achieved.
A Simple Technique for High Resistance Measurement
ERIC Educational Resources Information Center
Aguilar, Horacio Munguia; Landin, Ramon Ochoa
2012-01-01
A simple electronic system for the measurement of high values of resistance is shown. This system allows the measurement of resistance in the range of a few megohm up to 10[superscript 9] [omega]. We have used this system for the evaluation of CdS thin film resistance, but other practical uses in the basic physics laboratory are presented.…
Special Relativity in the School Laboratory: A Simple Apparatus for Cosmic-Ray Muon Detection
ERIC Educational Resources Information Center
Singh, P.; Hedgeland, H.
2015-01-01
We use apparatus based on two Geiger-Müller tubes, a simple electronic circuit and a Raspberry Pi computer to illustrate relativistic time dilation affecting cosmic-ray muons travelling through the atmosphere to the Earth's surface. The experiment we describe lends itself to both classroom demonstration to accompany the topic of special relativity…
A Simple and Affordable TTL Processor for the Classroom
ERIC Educational Resources Information Center
Feinberg, Dave
2007-01-01
This paper presents a simple 4 bit computer processor design that may be built using TTL chips for less than $65. In addition to describing the processor itself in detail, we discuss our experience using the laboratory kit and its associated machine instruction set to teach computer architecture to high school students. (Contains 3 figures and 5…
How to maintain blood supply during computer network breakdown: a manual backup system.
Zeiler, T; Slonka, J; Bürgi, H R; Kretschmer, V
2000-12-01
Electronic data management systems using computer network systems and client/server architecture are increasingly used in laboratories and transfusion services. Severe problems arise if there is no network access to the database server and critical functions are not available. We describe a manual backup system (MBS) developed to maintain the delivery of blood products to patients in a hospital transfusion service in case of a computer network breakdown. All data are kept on a central SQL database connected to peripheral workstations in a local area network (LAN). Request entry from wards is performed via machine-readable request forms containing self-adhesive specimen labels with barcodes for test tubes. Data entry occurs on-line by bidirectional automated systems or off-line manually. One of the workstations in the laboratory contains a second SQL database which is frequently and incrementally updated. This workstation is run as a stand-alone, read-only database if the central SQL database is not available. In case of a network breakdown, the time-graded MBS is launched. Patient data, requesting ward and ordered tests/requests, are photocopied through a template from the request forms on special MBS worksheets serving as laboratory journal for manual processing and result report (a copy is left in the laboratory). As soon as the network is running again the data from the off-line period are entered into the primary SQL server. The MBS was successfully used at several occasions. The documentation of a 90-min breakdown period is presented in detail. Additional work resulted from the copy work and the belated manual data entry after restoration of the system. There was no delay in issue of blood products or result reporting. The backup system described has been proven to be simple, quick and safe to maintain urgent blood supply and distribution of laboratory results in case of unexpected network breakdown.
NASA Astrophysics Data System (ADS)
dos Santos, J. M. F.; Veloso, J. F. C. A.; Monteiro, C. M. B.
2004-01-01
We describe a simple experiment intended for didactic laboratory vacuum classes of undergraduate courses, using a helium leak detector. The helium throughput flowing into the vacuum volume due to the permeability of materials can be taken as a real leak, which can be measured with the helium leak detector. The experiment allows students to perform actual measurements of helium permeability constants of different materials, and access the dependence of the helium permeability throughput on the material thickness, area and helium pressure differential. As an example, a set of measurements are presented for Kapton foils, exhibiting results that are in good agreement with those presented in the literature.
Muñoz, Constanza; Zumarán, Cecilia; González, Tamara; Wozniak, Aniela; Castillo, Claudia; García, Patricia
2017-08-01
The detection of carbapenemase-producing gram negative bacilli is complicated, because there are available multiple options of test. The confirmation of the enzyme by molecular characterization is not available in all laboratories in our country. To propose a fast, efficient and simple strategy to detect and confirm CPB. 39 CPB isolates and 8 non-producing were used to evaluate the phenotypic test Carba NP, CarbAcineto NP and Blue-Carba, validating the test Xpert® Carba-R, to be used directly with bacterial colonies with conventional PCR. The sensitivity of Carba NP, CarbAcineto NP and Blue-Carba was 79,5; 87,2 y 84,6%, respectively; and specificity was 79.5; 87.2 and 84.6%, respectively. The limit of detection of Xpert® Carba-R was different for each carbapenemasa: 40.8 ufc/reaction to KPC and NDM and 30.6 ufc/reaction to VIM. On isolates with decreased susceptibility to carbapenems we propose to use as screening the test CarbAcineto NP, follow by Xpert®Carba-R to characterize the carbapenemase and adopt specific infection control measures.
Herzog, Bastian; Lemmer, Hilde; Horn, Harald; Müller, Elisabeth
2014-02-22
Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. In laboratory setups, xenobiotics concentrations above 1.0 mg L(-1) without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum.
2014-01-01
Background Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. Results The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. Conclusions In laboratory setups, xenobiotics concentrations above 1.0 mg L-1 without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum. PMID:24558966
Fuel Cell Development and Test Laboratory | Energy Systems Integration
Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel a fuel cell test in the Fuel Cell Development and Test Laboratory. Capability Hubs The Fuel Cell
49 CFR 40.85 - What drugs do laboratories test for?
Code of Federal Regulations, 2013 CFR
2013-10-01
... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2013-10-01 2013-10-01 false What drugs do laboratories test for? 40.85 Section...
49 CFR 40.81 - What laboratories may be used for DOT drug testing?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...
49 CFR 40.85 - What drugs do laboratories test for?
Code of Federal Regulations, 2014 CFR
2014-10-01
... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2014-10-01 2014-10-01 false What drugs do laboratories test for? 40.85 Section...
49 CFR 40.81 - What laboratories may be used for DOT drug testing?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 1 2012-10-01 2012-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...
49 CFR 40.81 - What laboratories may be used for DOT drug testing?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 1 2014-10-01 2014-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...
49 CFR 40.81 - What laboratories may be used for DOT drug testing?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...
49 CFR 40.85 - What drugs do laboratories test for?
Code of Federal Regulations, 2011 CFR
2011-10-01
... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2011-10-01 2011-10-01 false What drugs do laboratories test for? 40.85 Section...
49 CFR 40.85 - What drugs do laboratories test for?
Code of Federal Regulations, 2012 CFR
2012-10-01
... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2012-10-01 2012-10-01 false What drugs do laboratories test for? 40.85 Section...
49 CFR 40.85 - What drugs do laboratories test for?
Code of Federal Regulations, 2010 CFR
2010-10-01
... WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.85 What drugs do laboratories test for? As a laboratory, you must test for the following five drugs or classes of drugs in a DOT drug... 49 Transportation 1 2010-10-01 2010-10-01 false What drugs do laboratories test for? 40.85 Section...
49 CFR 40.81 - What laboratories may be used for DOT drug testing?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...
The Leeb Hardness Test for Rock: An Updated Methodology and UCS Correlation
NASA Astrophysics Data System (ADS)
Corkum, A. G.; Asiri, Y.; El Naggar, H.; Kinakin, D.
2018-03-01
The Leeb hardness test (LHT with test value of L D ) is a rebound hardness test, originally developed for metals, that has been correlated with the Unconfined Compressive Strength (test value of σ c ) of rock by several authors. The tests can be carried out rapidly, conveniently and nondestructively on core and block samples or on rock outcrops. This makes the relatively small LHT device convenient for field tests. The present study compiles test data from literature sources and presents new laboratory testing carried out by the authors to develop a substantially expanded database with wide-ranging rock types. In addition, the number of impacts that should be averaged to comprise a "test result" was revisited along with the issue of test specimen size. Correlation for L D and σ c for various rock types is provided along with recommended testing methodology. The accuracy of correlated σ c estimates was assessed and reasonable correlations were observed between L D and σ c . The study findings show that LHT can be useful particularly for field estimation of σ c and offers a significant improvement over the conventional field estimation methods outlined by the ISRM (e.g., hammer blows). This test is rapid and simple, with relatively low equipment costs, and provides a reasonably accurate estimate of σ c .
Birdcage volume coils and magnetic resonance imaging: a simple experiment for students.
Vincent, Dwight E; Wang, Tianhao; Magyar, Thalia A K; Jacob, Peni I; Buist, Richard; Martin, Melanie
2017-01-01
This article explains some simple experiments that can be used in undergraduate or graduate physics or biomedical engineering laboratory classes to learn how birdcage volume radiofrequency (RF) coils and magnetic resonance imaging (MRI) work. For a clear picture, and to do any quantitative MRI analysis, acquiring images with a high signal-to-noise ratio (SNR) is required. With a given MRI system at a given field strength, the only means to change the SNR using hardware is to change the RF coil used to collect the image. RF coils can be designed in many different ways including birdcage volume RF coil designs. The choice of RF coil to give the best SNR for any MRI study is based on the sample being imaged. The data collected in the simple experiments show that the SNR varies as inverse diameter for the birdcage volume RF coils used in these experiments. The experiments were easily performed by a high school student, an undergraduate student, and a graduate student, in less than 3 h, the time typically allotted for a university laboratory course. The article describes experiments that students in undergraduate or graduate laboratories can perform to observe how birdcage volume RF coils influence MRI measurements. It is designed for students interested in pursuing careers in the imaging field.
Laboratories | Energy Systems Integration Facility | NREL
laboratories to be safely divided into multiple test stand locations (or "capability hubs") to enable Fabrication Laboratory Energy Systems High-Pressure Test Laboratory Energy Systems Integration Laboratory Energy Systems Sensor Laboratory Fuel Cell Development and Test Laboratory High-Performance Computing
Ambrosio, Louis J.; Baeza, J. Antonio
2016-01-01
Host monopolization theory predicts symbiotic organisms inhabiting morphologically simple, relatively small and scarce hosts to live solitarily as a result of territorial behaviors. We tested this prediction with Tunicotheres moseri, an endosymbiotic crab dwelling in the atrial chamber of the morphologically simple, small, and relatively scarce ascidian Styela plicata. As predicted, natural populations of T. moseri inhabit ascidian hosts solitarily with greater frequency than expected by chance alone. Furthermore, laboratory experiments demonstrated that intruder crabs take significantly longer to colonize previously infected compared to uninfected hosts, indicating as expected, that resident crabs exhibit monopolization behaviors. While territoriality does occur, agonistic behaviors employed by T. moseri do not mirror the overt behaviors commonly reported for other territorial crustaceans. Documented double and triple cohabitations in the field coupled with laboratory observations demonstrating the almost invariable success of intruder crabs colonizing occupied hosts, suggest that territoriality is ineffective in completely explaining the solitary social habit of this species. Additional experiments showed that T. moseri juveniles and adults, when searching for ascidians use chemical cues to avoid hosts occupied by conspecifics. This conspecific avoidance behavior reported herein is a novel strategy most likely employed to preemptively resolve costly territorial conflicts. In general, this study supports predictions central to host monopolization theory, but also implies that alternative behavioral strategies (i.e., conflict avoidance) may be more important than originally thought in explaining the host use pattern of symbiotic organisms. PMID:26910474
Ambrosio, Louis J; Baeza, J Antonio
2016-01-01
Host monopolization theory predicts symbiotic organisms inhabiting morphologically simple, relatively small and scarce hosts to live solitarily as a result of territorial behaviors. We tested this prediction with Tunicotheres moseri, an endosymbiotic crab dwelling in the atrial chamber of the morphologically simple, small, and relatively scarce ascidian Styela plicata. As predicted, natural populations of T. moseri inhabit ascidian hosts solitarily with greater frequency than expected by chance alone. Furthermore, laboratory experiments demonstrated that intruder crabs take significantly longer to colonize previously infected compared to uninfected hosts, indicating as expected, that resident crabs exhibit monopolization behaviors. While territoriality does occur, agonistic behaviors employed by T. moseri do not mirror the overt behaviors commonly reported for other territorial crustaceans. Documented double and triple cohabitations in the field coupled with laboratory observations demonstrating the almost invariable success of intruder crabs colonizing occupied hosts, suggest that territoriality is ineffective in completely explaining the solitary social habit of this species. Additional experiments showed that T. moseri juveniles and adults, when searching for ascidians use chemical cues to avoid hosts occupied by conspecifics. This conspecific avoidance behavior reported herein is a novel strategy most likely employed to preemptively resolve costly territorial conflicts. In general, this study supports predictions central to host monopolization theory, but also implies that alternative behavioral strategies (i.e., conflict avoidance) may be more important than originally thought in explaining the host use pattern of symbiotic organisms.
Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K
2015-01-01
Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.
Quantum Dots in a Polymer Composite: A Convenient Particle-in-a-Box Laboratory Experiment
ERIC Educational Resources Information Center
Rice, Charles V.; Giffin, Guinevere A.
2008-01-01
Semiconductor quantum dots are at the forefront of materials science chemistry with applications in biological imaging and photovoltaic technologies. We have developed a simple laboratory experiment to measure the quantum-dot size from fluorescence spectra. A major roadblock of quantum-dot based exercises is the particle synthesis and handling;…
ERIC Educational Resources Information Center
Gokalp, Sumeyra; Horton, William; Jónsdóttir-Lewis, Elfa B.; Foster, Michelle; Török, Marianna
2018-01-01
To facilitate learning advanced instrumental techniques, essential tools for visualizing biomaterials, a simple and versatile laboratory exercise demonstrating the use of Atomic Force Microscopy (AFM) in biomedical applications was developed. In this experiment, the morphology of heat-denatured and amyloid-type aggregates formed from a low-cost…
X-Ray Diffraction of Intermetallic Compounds: A Physical Chemistry Laboratory Experiment
ERIC Educational Resources Information Center
Varberg, Thomas D.; Skakuj, Kacper
2015-01-01
Here we describe an experiment for the undergraduate physical chemistry laboratory in which students synthesize the intermetallic compounds AlNi and AlNi3 and study them by X-ray diffractometry. The compounds are synthesized in a simple one-step reaction occurring in the solid state. Powder X-ray diffractograms are recorded for the two compounds…
ERIC Educational Resources Information Center
Bonomo, Raffaele P.; Tabbi, Giovanni; Vagliasindi, Laura I.
2012-01-01
A simple experiment was devised to let students determine the solubility and solubility product, "K"[subscript sp], of calcium sulfate dihydrate in a first-level laboratory. The students experimentally work on an intriguing equilibrium law: the constancy of the product of the ion concentrations of a sparingly soluble salt. The determination of…
Dipeptide Structural Analysis Using Two-Dimensional NMR for the Undergraduate Advanced Laboratory
ERIC Educational Resources Information Center
Gonzalez, Elizabeth; Dolino, Drew; Schwartzenburg, Danielle; Steiger, Michelle A.
2015-01-01
A laboratory experiment was developed to introduce students in either an organic chemistry or biochemistry lab course to two-dimensional nuclear magnetic resonance (2D NMR) spectroscopy using simple biomolecules. The goal of this experiment is for students to understand and interpret the information provided by a 2D NMR spectrum. Students are…
Rolling Friction on a Wheeled Laboratory Cart
ERIC Educational Resources Information Center
Mungan, Carl E.
2012-01-01
A simple model is developed that predicts the coefficient of rolling friction for an undriven laboratory cart on a track that is approximately independent of the mass loaded onto the cart and of the angle of inclination of the track. The model includes both deformation of the wheels/track and frictional torque at the axles/bearings. The concept of…
ERIC Educational Resources Information Center
Twomey, Patrick; O'Sullivan, Colm; O'Riordan, John
2009-01-01
A simple undergraduate experiment designed to study cooling purely by radiation and cooling by a combination of convection and radiation is described. Results indicate that the contribution from radiative cooling in normal laboratory experiments is more significant than students often realize, even in the case of forced cooling. (Contains 1…
Prussian Blue Coated Electrode as a Sensor for Electroinactive Cations in Aqueous Solutions
ERIC Educational Resources Information Center
Byrd, Houston; Chapman, Blake E.; Talley, Christopher L.
2013-01-01
Prussian Blue (PB) is an excellent material as a sensor for electroinactive cations because of its electrochemical behavior and its zeolytic character. A simple 3-h laboratory designed for a quantitative analysis or an instrumental methods course is reported. This laboratory studies the transport of various cations into a PB-modified electrode…