Organizing for low cost space operations - Status and plans
NASA Technical Reports Server (NTRS)
Lee, C.
1976-01-01
Design features of the Space Transportation System (vehicle reuse, low cost expendable components, simple payload interfaces, standard support systems) must be matched by economical operational methods to achieve low operating and payload costs. Users will be responsible for their own payloads and will be charged according to the services they require. Efficient use of manpower, simple documentation, simplified test, checkout, and flight planning are firm goals, together with flexibility for quick response to varying user needs. Status of the Shuttle hardware, plans for establishing low cost procedures, and the policy for user charges are discussed.
New simple and low-cost methods for periodic checks of Cyclone® Plus Storage Phosphor System.
Edalucci, Elisabetta; Maffione, Anna Margherita; Fornasier, Maria Rosa; De Denaro, Mario; Scian, Giovanni; Dore, Franca; Rubello, Domenico
2017-01-01
The recent large use of the Cyclone® Plus Storage Phosphor System, especially in European countries, as imaging system for quantification of radiochemical purity of radiopharmaceuticals raised the problem of setting the periodic controls as required by European Legislation. We described simple, low-cost methods for Cyclone® Plus quality controls, which can be useful to evaluate the performance measurement of this imaging system.
Simple, Low-Cost Data Collection Methods for Agricultural Field Studies.
ERIC Educational Resources Information Center
Koenig, Richard T.; Winger, Marlon; Kitchen, Boyd
2000-01-01
Summarizes relatively simple and inexpensive methods for collecting data from agricultural field studies. Describes methods involving on-farm testing, crop yield measurement, quality evaluations, weed control effectiveness, plant nutrient status, and other measures. Contains 29 references illustrating how these methods were used to conduct…
A fast and simple bonding method for low cost microfluidic chip fabrication
NASA Astrophysics Data System (ADS)
Yin, Zhifu; Zou, Helin
2018-01-01
With the development of the microstructure fabrication technique, microfluidic chips are widely used in biological and medical researchers. Future advances in their commercial applications depend on the mass bonding of microfluidic chip. In this study we are presenting a simple, low cost and fast way of bonding microfluidic chips at room temperature. The influence of the bonding pressure on the deformation of the microchannel and adhesive tape was analyzed by numerical simulation. By this method, the microfluidic chip can be fully sealed at low temperature and pressure without using any equipment. The dye water and gas leakage test indicated that the microfluidic chip can be bonded without leakage or block and its bonding strength can up to 0.84 MPa.
Small-Scale and Low Cost Electrodes for "Standard" Reduction Potential Measurements
ERIC Educational Resources Information Center
Eggen, Per-Odd; Kvittingen, Lise
2007-01-01
The construction of three simple and inexpensive electrodes, hydrogen, and chlorine and copper electrode is described. This simple method will encourage students to construct their own electrode and better help in understanding precipitation and other electrochemistry concepts.
de Sena, Rodrigo Caciano; Soares, Matheus; Pereira, Maria Luiza Oliveira; da Silva, Rogério Cruz Domingues; do Rosário, Francisca Ferreira; da Silva, Joao Francisco Cajaiba
2011-01-01
The development of a simple, rapid and low cost method based on video image analysis and aimed at the detection of low concentrations of precipitated barium sulfate is described. The proposed system is basically composed of a webcam with a CCD sensor and a conventional dichroic lamp. For this purpose, software for processing and analyzing the digital images based on the RGB (Red, Green and Blue) color system was developed. The proposed method had shown very good repeatability and linearity and also presented higher sensitivity than the standard turbidimetric method. The developed method is presented as a simple alternative for future applications in the study of precipitations of inorganic salts and also for detecting the crystallization of organic compounds. PMID:22346607
A simple and inexpensive method for muddy shore profiling
NASA Astrophysics Data System (ADS)
Chowdhury, Sayedur Rahman; Hossain, M. Shahadat; Sharifuzzaman, S. M.
2014-11-01
There are several well-established methods for obtaining beach profiles, and more accurate and precise high-tech methods are emerging. Traditional low-cost methods requiring minimal user skill or training are still popular among professionals, scientists, and coastal zone management practitioners. Simple methods are being developed with a primary focus on sand and gravel beaches. This paper describes a simple, low-cost, manual field method for measuring profiles of beaches, which is particularly suitable for muddy shores. The equipment is a type of flexible U-tube manometer that uses liquid columns in vertical tubes to measure differences in elevation; the supporting frame is constructed from wooden poles with base disks, which hold measuring scales and a PVC tube. The structure was trialed on a mudflat characterized by a 20-40-cm-thick surface layer of silt and clay, located at the Kutubdia Island, Bangladesh. The study results are discussed with notes on the method's applicability, advantages and limitations, and several optional modifications for different scenarios for routine profiling of muddy shores. The equipment can be used by one person or two people, and the accuracy of the method is comparable to those in other methods. The equipment can also be used on sandy or gravel beaches.
A simple fabrication of CH3NH3PbI3 perovskite for solar cells using low-purity PbI2
NASA Astrophysics Data System (ADS)
Guo, Nanjie; Zhang, Taiyang; Li, Ge; Xu, Feng; Qian, Xufang; Zhao, Yixin
2017-01-01
The CH3NH3PbI3 (MAPbI3) perovskite was usually prepared by high-purity PbI2 with high cost. The low cost and low-purity PbI2 was seldom reported for fabrication of MAPbI3 because it cannot even dissolve well in widely adopted solvent of DMF. We developed an easy method to adapt low-purity PbI2 for fabrication of high quality MAPbI3 just by the simple addition of some hydrochloric acid into the mixture of low-purity PbI2, MAI and DMF. This straightforward method can not only help dissolve the low quality PbI2 by reacting with some impurities in DMF, but also lead to a successful fabrication of high-quality perovskite solar cells with up to 14.80% efficiency comparable to the high quality PbI2 precursors. Project supported by the National Natural Science Foundation of China (Nos. 51372151, 21303103) and Houyingdong Grant (No. 151046).
Leng, Pei-Qiang; Zhao, Feng-Lan; Yin, Bin-Cheng; Ye, Bang-Ce
2015-05-21
We developed a novel colorimetric method for rapid detection of biogenic amines based on arylalkylamine N-acetyltransferase (aaNAT). The proposed method offers distinct advantages including simple handling, high speed, low cost, good sensitivity and selectivity.
A simple, and potentially low-cost method for measuring the prevalence of childhood obesity.
Routh, K; Rao, J N; Denley, J
2006-03-01
Recent official publications have highlighted obesity as one of the biggest threats to public health and the prevalence of obesity in children is widely believed to be rising rapidly. However, there are no data on the prevalence of childhood obesity at a local level. We have developed a simple low-cost method of gaining such data by working with local schools. We designed our method on the observation that numeracy and data handling skills are often taught in schools by getting children to measure their height and weight. We recruited seven schools and offered them a numeracy lesson plan suitable for year 5 (aged 9-10) children together with healthcare staff to attend the lesson. As part of the lesson, each child's height and weight was measured and recorded anonymously. Parental consent was obtained on an 'opt out' basis. The method was evaluated by questionnaire. We gained data on body mass index for 252 children. In total, 20% of the children were overweight, and 7% obese. The brief questionnaire survey indicated that both teachers and school nurses were happy with the method and would repeat it. Weighing was carried out sensitively. Our findings were in line with national studies of the prevalence of childhood obesity. The method was simple, low-cost and acceptable to schools and school nurses. There seems no reason why this project cannot be used more widely across the Primary Care Trust (PCT) and beyond. We now propose to roll out the method across all primary schools in Birmingham.
High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory
ERIC Educational Resources Information Center
Frey, Douglas D.; Guo, Hui; Karnik, Nikhila
2013-01-01
This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…
A Simple and Inexpensive Capillary Holder for Thin-Layer Chromatography
ERIC Educational Resources Information Center
Pintea, Beniamin-Nicolae V.
2011-01-01
Thin-layer chromatography (TLC) is a widely used method of qualitative analysis in organic synthesis, as it uniquely combines low cost, rapidity, simplicity, versatility, small quantities of sample and low detection limits. The simplest and most economical method for the application of samples onto TLC plates is by hand, using glass capillaries.…
A simple and low-cost platform technology for producing pexiganan antimicrobial peptide in E. coli.
Zhao, Chun-Xia; Dwyer, Mirjana Dimitrijev; Yu, Alice Lei; Wu, Yang; Fang, Sheng; Middelberg, Anton P J
2015-05-01
Antimicrobial peptides, as a new class of antibiotics, have generated tremendous interest as potential alternatives to classical antibiotics. However, the large-scale production of antimicrobial peptides remains a significant challenge. This paper reports a simple and low-cost chromatography-free platform technology for producing antimicrobial peptides in Escherichia coli (E. coli). A fusion protein comprising a variant of the helical biosurfactant protein DAMP4 and the known antimicrobial peptide pexiganan is designed by joining the two polypeptides, at the DNA level, via an acid-sensitive cleavage site. The resulting DAMP4(var)-pexiganan fusion protein expresses at high level and solubility in recombinant E. coli, and a simple heat-purification method was applied to disrupt cells and deliver high-purity DAMP4(var)-pexiganan protein. Simple acid cleavage successfully separated the DAMP4 variant protein and the antimicrobial peptide. Antimicrobial activity tests confirmed that the bio-produced antimicrobial peptide has the same antimicrobial activity as the equivalent product made by conventional chemical peptide synthesis. This simple and low-cost platform technology can be easily adapted to produce other valuable peptide products, and opens a new manufacturing approach for producing antimicrobial peptides at large scale using the tools and approaches of biochemical engineering. © 2014 Wiley Periodicals, Inc.
Application of a Permethrin Immunosorbent Assay Method to Residential Soil and Dust Samples
A low-cost, high throughput bioanalytical screening method was developed for monitoring cis/trans-permethrin in dust and soil samples. The method consisted of a simple sample preparation procedure [sonication with dichloromethane followed by a solvent exchange into methanol:wate...
A Simple Educational Method for the Measurement of Liquid Binary Diffusivities
ERIC Educational Resources Information Center
Rice, Nicholas P.; de Beer, Martin P.; Williamson, Mark E.
2014-01-01
A simple low-cost experiment has been developed for the measurement of the binary diffusion coefficients of liquid substances. The experiment is suitable for demonstrating molecular diffusion to small or large undergraduate classes in chemistry or chemical engineering. Students use a cell phone camera in conjunction with open-source image…
Low cost charged-coupled device (CCD) based detectors for Shiga toxins activity analysis
USDA-ARS?s Scientific Manuscript database
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of foodborne pathogens and their toxins. We describe a simple and relatively low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemilumi...
Chapin, Thomas; Todd, Andrew S.; Zeigler, Matthew P.
2014-01-01
Water temperature and streamflow intermittency are critical parameters influencing aquatic ecosystem health. Low-cost temperature loggers have made continuous water temperature monitoring relatively simple but determining streamflow timing and intermittency using temperature data alone requires significant and subjective data interpretation. Electrical resistance (ER) sensors have recently been developed to overcome the major limitations of temperature-based methods for the assessment of streamflow intermittency. This technical note introduces the STIC (Stream Temperature, Intermittency, and Conductivity logger); a robust, low-cost, simple to build instrument that provides long-duration, high-resolution monitoring of both relative conductivity (RC) and temperature. Simultaneously collected temperature and RC data provide unambiguous water temperature and streamflow intermittency information that is crucial for monitoring aquatic ecosystem health and assessing regulatory compliance. With proper calibration, the STIC relative conductivity data can be used to monitor specific conductivity.
ERIC Educational Resources Information Center
Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe
2018-01-01
In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…
ERIC Educational Resources Information Center
Sur, Ujjal Kumar; Dhason, A.; Lakshminarayanan, V.
2012-01-01
A laboratory experiment is described in which students fabricate disk-shaped gold and platinum microelectrodes with diameters of 10-50 [mu]m by sealing sodalime glass with metal microwires. The electrodes are characterized by performing cyclic voltammetry in aqueous and acetonitrile solution. Commercial microelectrodes are expensive (cost depends…
A Simple Method for Determination of the Density of Granular Materials
ERIC Educational Resources Information Center
Tsutsumanova, G. G.; Kirilov, K. M.; Russev, S. C.
2012-01-01
A simple experiment using low cost equipment for the determination of the density of granular materials, without immersing them in a liquid, is presented. It is based only on the ideal gas state equation, so it is a good experimental task for undergraduate and high school students. (Contains 2 tables and 5 figures.)
Results of FM-TV threshold reduction investigation for the ATS F trust experiment
NASA Technical Reports Server (NTRS)
Brown, J. P.
1972-01-01
An investigation of threshold effects in FM TV was initiated to determine if any simple, low cost techniques were available which can reduce the subjective video threshold, applicable to low cost community TV reception via satellite. Two methods of eliminating these effects were examined: the use of standard video pre-emphasis, and the use of an additional circuit to blank the picture tube during the retrace period.
Printing method for organic light emitting device lighting
NASA Astrophysics Data System (ADS)
Ki, Hyun Chul; Kim, Seon Hoon; Kim, Doo-Gun; Kim, Tae-Un; Kim, Snag-Gi; Hong, Kyung-Jin; So, Soon-Yeol
2013-03-01
Organic Light Emitting Device (OLED) has a characteristic to change the electric energy into the light when the electric field is applied to the organic material. OLED is currently employed as a light source for the lighting tools because research has extensively progressed in the improvement of luminance, efficiency, and life time. OLED is widely used in the plate display device because of a simple manufacture process and high emitting efficiency. But most of OLED lighting projects were used the vacuum evaporator (thermal evaporator) with low molecular. Although printing method has lower efficiency and life time of OLED than vacuum evaporator method, projects of printing OLED actively are progressed because was possible to combine with flexible substrate and printing technology. Printing technology is ink-jet, screen printing and slot coating. This printing method allows for low cost and mass production techniques and large substrates. In this research, we have proposed inkjet printing for organic light-emitting devices has the dominant method of thick film deposition because of its low cost and simple processing. In this research, the fabrication of the passive matrix OLED is achieved by inkjet printing, using a polymer phosphorescent ink. We are measured optical and electrical characteristics of OLED.
Multiplexed microsatellite recovery using massively parallel sequencing
T.N. Jennings; B.J. Knaus; T.D. Mullins; S.M. Haig; R.C. Cronn
2011-01-01
Conservation and management of natural populations requires accurate and inexpensive genotyping methods. Traditional microsatellite, or simple sequence repeat (SSR), marker analysis remains a popular genotyping method because of the comparatively low cost of marker development, ease of analysis and high power of genotype discrimination. With the availability of...
A Simple Low-Cost Lock-In Amplifier for the Laboratory
ERIC Educational Resources Information Center
Sengupta, Sandip K.; Farnham, Jessica M.; Whitten, James E.
2005-01-01
The creation of a simple, low-cost lock-in amplifier (LIA) suitable for use in the chemistry teaching laboratory is described. The use of integrated circuits and few components are necessary to adequately accomplish lock-in amplification limited the total cost of construction to under US$100.
Sabino, Bruno Duarte; Torraca, Tathiana Guilliod; Moura, Claudia Melo; Rozenbaum, Hannah Felicia; de Castro Faria, Mauro Velho
2010-05-01
Foods contaminated with a granulated material similar to Temik (a commercial pesticide formulation containing the carbamate insecticide aldicarb) are often involved in accidental ingestion, suicides, and homicides in Brazil. We developed a simple technique to detect aldicarb. This technique is based on the inhibition of a stable preparation of the enzyme acetylcholinesterase, and it is specially adapted for forensic purposes. It comprises an initial extraction step with the solvent methylene chloride followed by a colorimetric acetylcholinesterase assay. We propose that results of testing contaminated forensic samples be expressed in aldicarb equivalents because, even though all other carbamates are also potent enzyme inhibitors, aldicarb is the contaminant most frequently found in forensic samples. This method is rapid (several samples can be run in a period of 2 h) and low cost. This method also proved to be precise and accurate, detecting concentrations as low as 40 microg/kg of aldicarb in meat samples.
A low noise and ultra-narrow bandwidth frequency-locked loop based on the beat method.
Gao, Wei; Sui, Jianping; Chen, Zhiyong; Yu, Fang; Sheng, Rongwu
2011-06-01
A novel frequency-locked loop (FLL) based on the beat method is proposed in this paper. Compared with other frequency feedback loops, this FLL is a digital loop with simple structure and very low noise. As shown in the experimental results, this FLL can be used to reduce close-in phase noise on atomic frequency standards, through which a composite frequency standard with ultra-low phase noise and low cost can be easily realized.
A Simple, Low-Cost Platform for Real-Time Isothermal Nucleic Acid Amplification
Craw, Pascal; Mackay, Ruth E.; Naveenathayalan, Angel; Hudson, Chris; Branavan, Manoharanehru; Sadiq, S. Tariq; Balachandran, Wamadeva
2015-01-01
Advances in microfluidics and the introduction of isothermal nucleic acid amplification assays have resulted in a range of solutions for nucleic acid amplification tests suited for point of care and field use. However, miniaturisation of instrumentation for such assays has not seen such rapid advances and fluorescence based assays still depend on complex, bulky and expensive optics such as fluorescence microscopes, photomultiplier tubes and sensitive lens assemblies. In this work we demonstrate a robust, low cost platform for isothermal nucleic acid amplification on a microfluidic device. Using easily obtainable materials and commercial off-the-shelf components, we show real time fluorescence detection using a low cost photodiode and operational amplifier without need for lenses. Temperature regulation on the device is achieved using a heater fabricated with standard printed circuit board fabrication methods. These facile construction methods allow fabrications at a cost compatible with widespread deployment to resource poor settings. PMID:26389913
Orr, G; Roth, M
2012-08-01
A low-voltage (mV) electronically triggered spot welding system for fabricating fine thermocouples and thin sheets used in high-temperature characterization of materials' properties is suggested. The system is based on the capacitance discharge method with a timed trigger for obtaining reliable and consistent welds. In contrast to existing techniques based on employing high voltage DC supplies for charging the capacitor or supplies with positive and negative rails, this method uses a simple, standard dual power supply available at most of the physical laboratories or can be acquired at a low cost. In addition, an efficient and simple method of fabricating non-sticking electrodes that do not contaminate the weld area is suggested and implemented.
NASA Astrophysics Data System (ADS)
Asiedu, Mercy Nyamewaa; Simhal, Anish; Lam, Christopher T.; Mueller, Jenna; Chaudhary, Usamah; Schmitt, John W.; Sapiro, Guillermo; Ramanujam, Nimmi
2018-02-01
The world health organization recommends visual inspection with acetic acid (VIA) and/or Lugol's Iodine (VILI) for cervical cancer screening in low-resource settings. Human interpretation of diagnostic indicators for visual inspection is qualitative, subjective, and has high inter-observer discordance, which could lead both to adverse outcomes for the patient and unnecessary follow-ups. In this work, we a simple method for automatic feature extraction and classification for Lugol's Iodine cervigrams acquired with a low-cost, miniature, digital colposcope. Algorithms to preprocess expert physician-labelled cervigrams and to extract simple but powerful color-based features are introduced. The features are used to train a support vector machine model to classify cervigrams based on expert physician labels. The selected framework achieved a sensitivity, specificity, and accuracy of 89.2%, 66.7% and 80.6% with majority diagnosis of the expert physicians in discriminating cervical intraepithelial neoplasia (CIN +) relative to normal tissues. The proposed classifier also achieved an area under the curve of 84 when trained with majority diagnosis of the expert physicians. The results suggest that utilizing simple color-based features may enable unbiased automation of VILI cervigrams, opening the door to a full system of low-cost data acquisition complemented with automatic interpretation.
Aqueous Solution-Phase Selenized CuIn(S,Se)2 Thin Film Solar Cells Annealed under Inert Atmosphere.
Oh, Yunjung; Yang, Wooseok; Kim, Jimin; Woo, Kyoohee; Moon, Jooho
2015-10-14
A nonvacuum solution-based approach can potentially be used to realize low cost, roll-to-roll fabrication of chalcopyrite CuIn(S,Se)2 (CISSe) thin film solar cells. However, most solution-based fabrication methods involve highly toxic solvents and inevitably require sulfurization and/or postselenization with hazardous H2S/H2Se gases. Herein, we introduce novel aqueous-based Cu-In-S and Se inks that contain an amine additive for producing a high-quality absorber layer. CISSe films were fabricated by simple deposition of Cu-In-S ink and Se ink followed by annealing under an inert atmosphere. Compositional and phase analyses confirmed that our simple aqueous ink-based method facilitated in-site selenization of the CIS layer. In addition, we investigated the molecular structures of our aqueous inks to determine how crystalline chalcopyrite absorber layers developed without sulfurization and/or postselenization. CISSe thin film solar cells annealed at 550 °C exhibited an efficiency of 4.55% under AM 1.5 illumination. The low-cost, nonvacuum method to deposit chalcopyrite absorber layers described here allows for safe and simple processing of thin film solar cells.
A System for Cooling inside a Glove Box
ERIC Educational Resources Information Center
Sanz, Martial
2010-01-01
An easy, efficient, reliable, and low-cost method of constructing a cooling system using a simple circulating pump is described. The system is employed in conjunction with an inert atmosphere glove box to achieve the synthesis of air- and moisture-sensitive compounds inside the glove box at controlled, low temperatures without contaminating the…
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.
Sanjay, Sharma T; Fu, Guanglei; Dou, Maowei; Xu, Feng; Liu, Rutao; Qi, Hao; Li, XiuJun
2015-11-07
Early and timely detection of disease biomarkers can prevent the spread of infectious diseases, and drastically decrease the death rate of people suffering from different diseases such as cancer and infectious diseases. Because conventional diagnostic methods have limited application in low-resource settings due to the use of bulky and expensive instrumentation, simple and low-cost point-of-care diagnostic devices for timely and early biomarker diagnosis is the need of the hour, especially in rural areas and developing nations. The microfluidics technology possesses remarkable features for simple, low-cost, and rapid disease diagnosis. There have been significant advances in the development of microfluidic platforms for biomarker detection of diseases. This article reviews recent advances in biomarker detection using cost-effective microfluidic devices for disease diagnosis, with the emphasis on infectious disease and cancer diagnosis in low-resource settings. This review first introduces different microfluidic platforms (e.g. polymer and paper-based microfluidics) used for disease diagnosis, with a brief description of their common fabrication techniques. Then, it highlights various detection strategies for disease biomarker detection using microfluidic platforms, including colorimetric, fluorescence, chemiluminescence, electrochemiluminescence (ECL), and electrochemical detection. Finally, it discusses the current limitations of microfluidic devices for disease biomarker detection and future prospects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ian Metzger, Jesse Dean
2010-12-31
This software requires inputs of simple water fixture inventory information and calculates the water/energy and cost benefits of various retrofit opportunities. This tool includes water conservation measures for: Low-flow Toilets, Low-flow Urinals, Low-flow Faucets, and Low-flow Showheads. This tool calculates water savings, energy savings, demand reduction, cost savings, and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.
Digital intermediate frequency QAM modulator using parallel processing
Pao, Hsueh-Yuan [Livermore, CA; Tran, Binh-Nien [San Ramon, CA
2008-05-27
The digital Intermediate Frequency (IF) modulator applies to various modulation types and offers a simple and low cost method to implement a high-speed digital IF modulator using field programmable gate arrays (FPGAs). The architecture eliminates multipliers and sequential processing by storing the pre-computed modulated cosine and sine carriers in ROM look-up-tables (LUTs). The high-speed input data stream is parallel processed using the corresponding LUTs, which reduces the main processing speed, allowing the use of low cost FPGAs.
Low-cost, solution processable carbon nanotube supercapacitors and their characterization
NASA Astrophysics Data System (ADS)
Lehtimäki, Suvi; Tuukkanen, Sampo; Pörhönen, Juho; Moilanen, Pasi; Virtanen, Jorma; Honkanen, Mari; Lupo, Donald
2014-06-01
We report ecological and low-cost carbon nanotube (CNT) supercapacitors fabricated using a simple, scalable solution processing method, where the use of a highly porous and electrically conductive active material eliminates the need for a current collector. Electrodes were fabricated on a poly(ethylene terephthalate) substrate from a printable multi-wall CNT ink, where the CNTs are solubilized in water using xylan as a dispersion agent. The dispersion method facilitates a very high concentration of CNTs in the ink. Supercapacitors were assembled using a paper separator and an aqueous NaCl electrolyte and the devices were characterized with a galvanostatic discharge method defined by an industrial standard. The capacitance of the 2 cm^2 devices was 6 mF/cm^2 (2.3 F/g) and equivalent series resistance 80 Ω . Low-cost supercapacitors fabricated from safe and environmentally friendly materials have potential applications as energy storage devices in ubiquitous and autonomous intelligence as well as in disposable low-end products.
A Simplified, Low-Cost Method for Polarized Light Microscopy
Maude, Richard J.; Buapetch, Wanchana; Silamut, Kamolrat
2009-01-01
Malaria pigment is an intracellular inclusion body that appears in blood and tissue specimens on microscopic examination and can help in establishing the diagnosis of malaria. In simple light microscopy, it can be difficult to discern from cellular background and artifacts. It has long been known that if polarized light microscopy is used, malaria pigment can be much easier to distinguish. However, this technique is rarely used because of the need for a relatively costly polarization microscope. We describe a simple and economical technique to convert any standard light microscope suitable for examination of malaria films into a polarization microscope. PMID:19861611
An improved method of measuring heart rate using a webcam
NASA Astrophysics Data System (ADS)
Liu, Yi; Ouyang, Jianfei; Yan, Yonggang
2014-09-01
Measuring heart rate traditionally requires special equipment and physical contact with the subject. Reliable non-contact and low-cost measurements are highly desirable for convenient and comfortable physiological self-assessment. Previous work has shown that consumer-grade cameras can provide useful signals for remote heart rate measurements. In this paper a simple and robust method of measuring the heart rate using low-cost webcam is proposed. Blood volume pulse is extracted by proper Region of Interest (ROI) and color channel selection from image sequences of human faces without complex computation. Heart rate is subsequently quantified by spectrum analysis. The method is successfully applied under natural lighting conditions. Results of experiments show that it takes less time, is much simpler, and has similar accuracy to the previously published and widely used method of Independent Component Analysis (ICA). Benefitting from non-contact, convenience, and low-costs, it provides great promise for popularization of home healthcare and can further be applied to biomedical research.
The mini-O, a digital superhet, or a truly low-cost Omega navigation receiver
NASA Technical Reports Server (NTRS)
Burhans, R. W.
1975-01-01
A quartz tuning fork filter circuit and some unique CMOS clock logic methods provide a very simple OMEGA-VLF receiver with true hyperbolic station pair phase difference outputs. An experimental system was implemented on a single battery-operated circuit board requiring only an external antenna preamplifier, and LOP output recorder. A bench evaluation and preliminary navigation tests indicate the technique is viable and can provide very low-cost OMEGA measurement systems. The method is promising for marine use with small boats in the present form, but might be implemented in conjunction with digital microprocessors for airborne navigation aids.
Hydrogen-enabled microstructure and fatigue strength engineering of titanium alloys
NASA Astrophysics Data System (ADS)
Paramore, James D.; Fang, Zhigang Zak; Dunstan, Matthew; Sun, Pei; Butler, Brady G.
2017-02-01
Traditionally, titanium alloys with satisfactory mechanical properties can only be produced via energy-intensive and costly wrought processes, while titanium alloys produced using low-cost powder metallurgy methods consistently result in inferior mechanical properties, especially low fatigue strength. Herein, we demonstrate a new microstructural engineering approach for producing low-cost titanium alloys with exceptional fatigue strength via the hydrogen sintering and phase transformation (HSPT) process. The high fatigue strength presented in this work is achieved by creating wrought-like microstructures without resorting to wrought processing. This is accomplished by generating an ultrafine-grained as-sintered microstructure through hydrogen-enabled phase transformations, facilitating the subsequent creation of fatigue-resistant microstructures via simple heat treatments. The exceptional strength, ductility, and fatigue performance reported in this paper are a breakthrough in the field of low-cost titanium processing.
Hydrogen-enabled microstructure and fatigue strength engineering of titanium alloys
Paramore, James D.; Fang, Zhigang Zak; Dunstan, Matthew; ...
2017-02-01
Traditionally, titanium alloys with satisfactory mechanical properties can only be produced via energy-intensive and costly wrought processes, while titanium alloys produced using low-cost powder metallurgy methods consistently result in inferior mechanical properties, especially low fatigue strength. Herein, we demonstrate a new microstructural engineering approach for producing low-cost titanium alloys with exceptional fatigue strength via the hydrogen sintering and phase transformation (HSPT) process. The high fatigue strength presented in this work is achieved by creating wroughtlike microstructures without resorting to wrought processing. This is accomplished by generating an ultrafine-grained as-sintered microstructure through hydrogen-enabled phase transformations, facilitating the subsequent creation of fatigue-resistantmore » microstructures via simple heat treatments. Finally, the exceptional strength, ductility, and fatigue performance reported in this paper are a breakthrough in the field of low-cost titanium processing.« less
Hydrogen-enabled microstructure and fatigue strength engineering of titanium alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paramore, James D.; Fang, Zhigang Zak; Dunstan, Matthew
Traditionally, titanium alloys with satisfactory mechanical properties can only be produced via energy-intensive and costly wrought processes, while titanium alloys produced using low-cost powder metallurgy methods consistently result in inferior mechanical properties, especially low fatigue strength. Herein, we demonstrate a new microstructural engineering approach for producing low-cost titanium alloys with exceptional fatigue strength via the hydrogen sintering and phase transformation (HSPT) process. The high fatigue strength presented in this work is achieved by creating wroughtlike microstructures without resorting to wrought processing. This is accomplished by generating an ultrafine-grained as-sintered microstructure through hydrogen-enabled phase transformations, facilitating the subsequent creation of fatigue-resistantmore » microstructures via simple heat treatments. Finally, the exceptional strength, ductility, and fatigue performance reported in this paper are a breakthrough in the field of low-cost titanium processing.« less
Hydrogen-enabled microstructure and fatigue strength engineering of titanium alloys
Paramore, James D.; Fang, Zhigang Zak; Dunstan, Matthew; Sun, Pei; Butler, Brady G.
2017-01-01
Traditionally, titanium alloys with satisfactory mechanical properties can only be produced via energy-intensive and costly wrought processes, while titanium alloys produced using low-cost powder metallurgy methods consistently result in inferior mechanical properties, especially low fatigue strength. Herein, we demonstrate a new microstructural engineering approach for producing low-cost titanium alloys with exceptional fatigue strength via the hydrogen sintering and phase transformation (HSPT) process. The high fatigue strength presented in this work is achieved by creating wrought-like microstructures without resorting to wrought processing. This is accomplished by generating an ultrafine-grained as-sintered microstructure through hydrogen-enabled phase transformations, facilitating the subsequent creation of fatigue-resistant microstructures via simple heat treatments. The exceptional strength, ductility, and fatigue performance reported in this paper are a breakthrough in the field of low-cost titanium processing. PMID:28145527
ERIC Educational Resources Information Center
Pe´rez, Eduardo
2015-01-01
The procedure of a physical chemistry experiment for university students must be designed in a way that the accuracy and precision of the measurements is properly maintained. However, in many cases, that requires costly and sophisticated equipment not readily available in developing countries. A simple, low-cost experiment to determine isobaric…
Yan, Sheng; Li, Yuxing; Zhu, Yuanqing; Liu, Minsu; Zhao, Qianbin; Yuan, Dan; Yun, Guolin; Zhang, Shiwu; Wen, Weijia; Tang, Shi-Yang; Li, Weihua
2018-06-01
This work presents a simple, low-cost method to fabricate semi-circular channels using solder paste, which can amalgamate the cooper surface to form a half-cylinder mold using the surface tension of Sn-Pd alloy (the main component in solder paste). This technique enables semi-circular channels to be manufactured with different dimensions. These semi-circular channels will then be integrated with a polymethylmethacrylate frame and machine screws to create miniaturized, portable microfluidic valves for sequential liquid delivery and particle synthesis. This approach avoids complicated fabrication processes and expensive facilities and thus has the potential to be a useful tool for lab-on-a-chip applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Xu, Yanan; Song, Dawei; Li, Li; An, Cuihua; Wang, Yijing; Jiao, LiFang; Yuan, Huatang
2014-04-01
A simple solvent method is proposed for the recovery of waste LixCoO2 from lithium-ion batteries, which employs inexpensive DMF to remove the binder of PVDF. This method is convenient to manipulate and low-cost to apply. Electrochemical investigations indicate that recovered LixCoO2 materials with a small amount of S-doping exhibit excellent properties as negative materials for alkaline rechargeable Ni/Co batteries. At the discharge current density of 100 mA g-1, the LixCoO2 + 1% S electrode displays the max discharge capacity of 357 mAh g-1 and outstanding capacity retention rate of 85.5% after 100 cycles. It could overcome not only the sophisticated, energy-intensive shortcomings of conventional recycling methods, but also the high-cost restriction on alkaline rechargeable Ni/Co batteries.
Simplified and lower cost methods for culinary-medicinal mushrooms cultivation.
Cleaver, Phillip D; Bailey, Cody; Holliday, John C
2012-01-01
The importance and prospect of growing mushrooms through utilization of low-cost, technologically simple methods for developing Third World countries has recently been outlined. Three different species from genus Pleurotus (P. djamor, P. pulmonarius, and P. sajor-caju) and one from genus Hypsizygus (H. ulmarius) were studied. Whole stalk wheat straw, shredded wheat straw, and ground maize cob (Zea mays) were used as the substrates. Wheat straw is the post-harvest stalk of Triticum aestivum. Biological efficiency (BE), growth dynamics, and photographs are provided for each cultivated strain, on different substrates, and substrate treatment comparisons are made. From several experiments conducted with various technologically simple methods of cultivation, it was found that all above mentioned species can be successfully cultivated at the village level in any country, be it highly developed or the poorest country on earth.
NASA Astrophysics Data System (ADS)
Song, Seok-Jeong; Kim, Tae-Il; Kim, Youngmi; Nam, Hyoungsik
2018-05-01
Recently, a simple, sensitive, and low-cost fluorescent indicator has been proposed to determine water contents in organic solvents, drugs, and foodstuffs. The change of water content leads to the change of the indicator's fluorescence color under the ultra-violet (UV) light. Whereas the water content values could be estimated from the spectrum obtained by a bulky and expensive spectrometer in the previous research, this paper demonstrates a simple and low-cost camera-based water content measurement scheme with the same fluorescent water indicator. Water content is calculated over the range of 0-30% by quadratic polynomial regression models with color information extracted from the captured images of samples. Especially, several color spaces such as RGB, xyY, L∗a∗b∗, u‧v‧, HSV, and YCBCR have been investigated to establish the optimal color information features over both linear and nonlinear RGB data given by a camera before and after gamma correction. In the end, a 2nd order polynomial regression model along with HSV in a linear domain achieves the minimum mean square error of 1.06% for a 3-fold cross validation method. Additionally, the resultant water content estimation model is implemented and evaluated in an off-the-shelf Android-based smartphone.
Xie, Yian; Liu, Yufeng; Wang, Yaoming; Zhu, Xiaolong; Li, Aimin; Zhang, Lei; Qin, Mingsheng; Lü, Xujie; Huang, Fuqiang
2014-04-28
Low-cost and high-yield preparation of CuInSe2 films is the bottleneck for promising CuInSe2-based thin film solar cells. Here, we developed a simple, safe and cost-effective method using thioacetic acid to fabricate the absorber films of CuIn(S,Se)2 (CISSe). Dissolution of Cu2O and In(OH)3 in thioacetic acid was attributed to the strong coordination ability of S. The adhesive precursor solution can be prepared without any heating, centrifugation and inert gas protection, superior to the previously reported methods. The precursor CISSe layer was easily deposited in air by spin coating to ensure low cost. Uniform and compact CISSe thin films with well-crystallized and pure-phased CISSe grains were obtained after one step annealing. The as-prepared CISSe thin films were successfully applied to solar cells and a energy conversion efficiency of 6.75% was achieved. This facile preparation provides a low-cost and easy method to fabricate Cu-based thin film solar cells.
Measurement of Antenna Bore-Sight Gain
NASA Technical Reports Server (NTRS)
Fortinberry, Jarrod; Shumpert, Thomas
2016-01-01
The absolute or free-field gain of a simple antenna can be approximated using standard antenna theory formulae or for a more accurate prediction, numerical methods may be employed to solve for antenna parameters including gain. Both of these methods will result in relatively reasonable estimates but in practice antenna gain is usually verified and documented via measurements and calibration. In this paper, a relatively simple and low-cost, yet effective means of determining the bore-sight free-field gain of a VHF/UHF antenna is proposed by using the Brewster angle relationship.
A simple method to synthesize polyhedral hexagonal boron nitride nanofibers
NASA Astrophysics Data System (ADS)
Lin, Liang-xu; Zheng, Ying; Li, Zhao-hui; shen, Xiao-nv; Wei, Ke-mei
2007-12-01
Hexagonal boron nitride (h-BN) fibers with polyhedral morphology were synthesized with a simple-operational, large-scale and low-cost method. The sample obtained was studied by X-ray photoelectron spectrometer (XPS), electron energy lose spectroscopy (EELS), X-ray powder diffraction (XRD), Fourier transformation infrared spectroscopy (FT-IR), etc., which matched with h-BN. Environment scanning electron microscopy (ESEM) and transmission electron microscope (TEM) indicated that the BN fibers possess polyhedral morphology. The diameter of the BN fibers is mainly in the range of 100-500 nm.
Aerial sketchmapping for monitoring forest conditions in Southern Brazil
Y. M. Malheiros de Oliveira; M. A. Doetzer Rosot; N. B. da Luz; W. M. Ciesla; E.W. Johnson; R. Rhea; J.F. Jr. Penteado
2006-01-01
Aerial sketchmapping is a simple, low cost remote sensing method used for detection and mapping of forest damage caused by biotic agents (insects, pathogens and other pests) and abiotic agents (wind, fire, storms, hurricane, ice storms) in North America. This method was introduced to Brazil in 2001/2002 via a USDA Forest Service/EMBRAPA technical exchange program,...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, C.
Almost every computer architect dreams of achieving high system performance with low implementation costs. A multigauge machine can reconfigure its data-path width, provide parallelism, achieve better resource utilization, and sometimes can trade computational precision for increased speed. A simple experimental method is used here to capture the main characteristics of multigauging. The measurements indicate evidence of near-optimal speedups. Adapting these ideas in designing parallel processors incurs low costs and provides flexibility. Several operational aspects of designing a multigauge machine are discussed as well. Thus, this research reports the technical, economical, and operational feasibility studies of multigauging.
A low-cost, tunable laser lock without laser frequency modulation
NASA Astrophysics Data System (ADS)
Shea, Margaret E.; Baker, Paul M.; Gauthier, Daniel J.
2015-05-01
Many experiments in optical physics require laser frequency stabilization. This can be achieved by locking to an atomic reference using saturated absorption spectroscopy. Often, the laser frequency is modulated and phase sensitive detection used. This method, while well-proven and robust, relies on expensive components, can introduce an undesirable frequency modulation into the laser, and is not easily frequency tuned. Here, we report a simple locking scheme similar to those implemented previously. We modulate the atomic resonances in a saturated absorption setup with an AC magnetic field created by a single solenoid. The same coil applies a DC field that allows tuning of the lock point. We use an auto-balanced detector to make our scheme more robust against laser power fluctuations and stray magnetic fields. The coil, its driver, and the detector are home-built with simple, cheap components. Our technique is low-cost, simple to setup, tunable, introduces no laser frequency modulation, and only requires one laser. We gratefully acknowledge the financial support of the NSF through Grant # PHY-1206040.
Dynamic beam steering at submm- and mm-wave frequencies using an optically controlled lens antenna
NASA Astrophysics Data System (ADS)
Gallacher, T. F.; Søndenâ, R.; Robertson, D. A.; Smith, G. M.
2013-05-01
We present details of our work which has been focused on improving the efficiency and scan rate of the photo-injected Fresnel zone plate antenna (piFZPA) technique which utilizes commercially available visible display technologies. This approach presents a viable low-cost solution for non-mechanical beam steering, suitable for many applications at (sub) mm-wave frequencies that require rapid beam steering capabilities in order to meet their technological goals, such as imaging, surveillance, and remote sensing. This method has the advantage of being comparatively low-cost, is based on a simple and flexible architecture, enabling rapid and precise arbitrary beam forming, and which is scalable to higher frame-rates and higher submm-wave frequencies. We discuss the various optimization stages of a range of piFZPA designs that implement fast visible projection displays, enabling up to 30,000 beams per second. We also outline the suitability of this technology across mm-wave and submm-wave frequencies as a low-cost and simple solution for dynamic optoelectronic beam steering.
Shape-Controlled Synthesis of Hybrid Nanomaterials via Three-Dimensional Hydrodynamic Focusing
2015-01-01
Shape-controlled synthesis of nanomaterials through a simple, continuous, and low-cost method is essential to nanomaterials research toward practical applications. Hydrodynamic focusing, with its advantages of simplicity, low-cost, and precise control over reaction conditions, has been used for nanomaterial synthesis. While most studies have focused on improving the uniformity and size control, few have addressed the potential of tuning the shape of the synthesized nanomaterials. Here we demonstrate a facile method to synthesize hybrid materials by three-dimensional hydrodynamic focusing (3D-HF). While keeping the flow rates of the reagents constant and changing only the flow rate of the buffer solution, the molar ratio of two reactants (i.e., tetrathiafulvalene (TTF) and HAuCl4) within the reaction zone varies. The synthesized TTF–Au hybrid materials possess very different and predictable morphologies. The reaction conditions at different buffer flow rates are studied through computational simulation, and the formation mechanisms of different structures are discussed. This simple one-step method to achieve continuous shape-tunable synthesis highlights the potential of 3D-HF in nanomaterials research. PMID:25268035
Shape-controlled synthesis of hybrid nanomaterials via three-dimensional hydrodynamic focusing.
Lu, Mengqian; Yang, Shikuan; Ho, Yi-Ping; Grigsby, Christopher L; Leong, Kam W; Huang, Tony Jun
2014-10-28
Shape-controlled synthesis of nanomaterials through a simple, continuous, and low-cost method is essential to nanomaterials research toward practical applications. Hydrodynamic focusing, with its advantages of simplicity, low-cost, and precise control over reaction conditions, has been used for nanomaterial synthesis. While most studies have focused on improving the uniformity and size control, few have addressed the potential of tuning the shape of the synthesized nanomaterials. Here we demonstrate a facile method to synthesize hybrid materials by three-dimensional hydrodynamic focusing (3D-HF). While keeping the flow rates of the reagents constant and changing only the flow rate of the buffer solution, the molar ratio of two reactants (i.e., tetrathiafulvalene (TTF) and HAuCl4) within the reaction zone varies. The synthesized TTF-Au hybrid materials possess very different and predictable morphologies. The reaction conditions at different buffer flow rates are studied through computational simulation, and the formation mechanisms of different structures are discussed. This simple one-step method to achieve continuous shape-tunable synthesis highlights the potential of 3D-HF in nanomaterials research.
Barringer, J.L.; Johnsson, P.A.
1996-01-01
Titrations for alkalinity and acidity using the technique described by Gran (1952, Determination of the equivalence point in potentiometric titrations, Part II: The Analyst, v. 77, p. 661-671) have been employed in the analysis of low-pH natural waters. This report includes a synopsis of the theory and calculations associated with Gran's technique and presents a simple and inexpensive method for performing alkalinity and acidity determinations. However, potential sources of error introduced by the chemical character of some waters may limit the utility of Gran's technique. Therefore, the cost- and time-efficient method for performing alkalinity and acidity determinations described in this report is useful for exploring the suitability of Gran's technique in studies of water chemistry.
Diazo processing of LANDSAT imagery: A low-cost instructional technique
NASA Technical Reports Server (NTRS)
Lusch, D. P.
1981-01-01
Diazo processing of LANDSAT imagery is a relatively simple and cost effective method of producing enhanced renditions of the visual LANDSAT products. This technique is capable of producing a variety of image enhancements which have value in a teaching laboratory environment. Additionally, with the appropriate equipment, applications research which relys on accurate and repeatable results is possible. Exposure and development equipment options, diazo materials, and enhancement routines are discussed.
Preparation and properties of low-cost graphene counter electrodes for dye-sensitized solar cells
NASA Astrophysics Data System (ADS)
Wu, Qishuang; Shen, Yue; Wang, Qiandi; Gu, Feng; Cao, Meng; Wang, Linjun
2013-12-01
With the advantages of excellent electrical properties, high catalytic activity and low-cost preparation, Graphene is one of the most expected carbon materials to replace the expensive Pt as counter electrodes for dye-sensitized solar cells (DSSCs). In this paper, graphene counter electrodes were obtained by simple doctor-blade coating method on fluorine tin oxides (FTOs). The samples were investigated by X-ray diffraction (XRD), Raman spectroscopy and scanning electron microscope (SEM). Then the low-cost graphene electrodes were applied in typical sandwich-type DSSCs with TiO2 or ZnO as photoanodes, and their photoelectric conversion efficiency (η) were about 4.34% and 2.28%, respectively, which were a little lower than those of Pt electrodes but much higher than those of graphite electrodes. This law was consistent with the test results of electrochemical impedance spectroscopy (EIS). Low-cost graphene electrodes can be applied in DSSCs by process optimization.
NASA Astrophysics Data System (ADS)
Tomes, John J.; Finlayson, Chris E.
2016-09-01
We report upon the exploitation of the latest 3D printing technologies to provide low-cost instrumentation solutions, for use in an undergraduate level final-year project. The project addresses prescient research issues in optoelectronics, which would otherwise be inaccessible to such undergraduate student projects. The experimental use of an integrating sphere in conjunction with a desktop spectrometer presents opportunities to use easily handled, low cost materials as a means to illustrate many areas of physics such as spectroscopy, lasers, optics, simple circuits, black body radiation and data gathering. Presented here is a 3rd year undergraduate physics project which developed a low cost (£25) method to manufacture an experimentally accurate integrating sphere by 3D printing. Details are given of both a homemade internal reflectance coating formulated from readily available materials, and a robust instrument calibration method using a tungsten bulb. The instrument is demonstrated to give accurate and reproducible experimental measurements of luminescence quantum yield of various semiconducting fluorophores, in excellent agreement with literature values.
Development of a simple and low cost microbioreactor for high-throughput bioprocessing.
Rahman, Pattanathu K S M; Pasirayi, Godfrey; Auger, Vincent; Ali, Zulfiqur
2009-02-01
A simple microbioreactor for high-throughput bioprocessing made from low cost polymer polytetrafluoroethylene (PTFE) tubes with a working volume of 1.5 ml is described. We have developed a microfluidic system that handles a small population of cells of a model microorganism, Pseudomonas aeruginosa DS10-129. Under the conditions of the microbioreactor, the organism produced extracellular secondary metabolites by using nutrient broth modified with glycerol. Pyocyanins were isolated from the fermented medium as a metabolite of interest. Antibiotic properties of pyocyanin were effective against a number of microorganisms such as Staphylococcus aureus, S. epidermis, Bacillus subtilis, Micrococcus luteus and Saccharomyces cerevisiae. Batch fermentation of the model organism in the microbioreactor was compared to shake-flask and conventional bench fermenter methods. Results obtained from the microbioreactor compared favourably with the conventional processes.
Solution to the Problem of Calibration of Low-Cost Air Quality Measurement Sensors in Networks.
Miskell, Georgia; Salmond, Jennifer A; Williams, David E
2018-04-27
We provide a simple, remote, continuous calibration technique suitable for application in a hierarchical network featuring a few well-maintained, high-quality instruments ("proxies") and a larger number of low-cost devices. The ideas are grounded in a clear definition of the purpose of a low-cost network, defined here as providing reliable information on air quality at small spatiotemporal scales. The technique assumes linearity of the sensor signal. It derives running slope and offset estimates by matching mean and standard deviations of the sensor data to values derived from proxies over the same time. The idea is extremely simple: choose an appropriate proxy and an averaging-time that is sufficiently long to remove the influence of short-term fluctuations but sufficiently short that it preserves the regular diurnal variations. The use of running statistical measures rather than cross-correlation of sites means that the method is robust against periods of missing data. Ideas are first developed using simulated data and then demonstrated using field data, at hourly and 1 min time-scales, from a real network of low-cost semiconductor-based sensors. Despite the almost naïve simplicity of the method, it was robust for both drift detection and calibration correction applications. We discuss the use of generally available geographic and environmental data as well as microscale land-use regression as means to enhance the proxy estimates and to generalize the ideas to other pollutants with high spatial variability, such as nitrogen dioxide and particulates. These improvements can also be used to minimize the required number of proxy sites.
Design of a cardiac monitor in terms of parameters of QRS complex.
Chen, Zhen-cheng; Ni, Li-li; Su, Ke-ping; Wang, Hong-yan; Jiang, Da-zong
2002-08-01
Objective. To design a portable cardiac monitor system based on the available ordinary ECG machine and works on the basis of QRS parameters. Method. The 80196 single chip microcomputer was used as the central microprocessor and real time electrocardiac signal was collected and analyzed [correction of analysized] in the system. Result. Apart from the performance of an ordinary monitor, this machine possesses also the following functions: arrhythmia analysis, HRV analysis, alarm, freeze, and record of automatic papering. Convenient in carrying, the system is powered by AC or DC sources. Stability, low power and low cost are emphasized in the hardware design; and modularization method is applied in software design. Conclusion. Popular in usage and low cost made the portable monitor system suitable for use under simple conditions.
Li, Zhen; Zhu, Wenping; Zhang, Jinwen; Jiang, Jianhui; Shen, Guoli; Yu, Ruqin
2013-07-07
A label-free fluorescent DNA biosensor has been presented based on isothermal circular strand-displacement polymerization reaction (ICSDPR) combined with graphene oxide (GO) binding. The proposed method is simple and cost-effective with a low detection limit of 4 pM, which compares favorably with other GO-based homogenous DNA detection methods.
Cost and unit cost calculations using step-down accounting.
Conteh, Lesong; Walker, Damian
2004-03-01
There is paucity of unit cost data from low- and middle-income countries, although recent initiatives have emerged to help rectify this. The limited budgets assigned to health care facilities mean that health planners and managers must be able to account for the resources used in health facilities as well as use them efficiently. Step-down cost accounting (SDCA) offers a relatively simple method for generating cost and unit cost data at the facility level. However, to the best of our knowledge, there is a lack of clear and concise guidance on how to undertake SDCA. Therefore, this paper, using a worked example, illustrates the different steps involved to generate cost and unit costs for a small hospital.
Song, Shi-Lin
2013-04-01
To seek a precise and simple method for localization of acupoint in anatomical experiment teaching. Medical bone needles were inserted into acupoints. Then, self-mode copper probe needles were thrust along the center of the bone needles to open the inner structures of acuppoints. And probe needles were replaced by colored plastic tubes. Finally, bone needles were withdrawn so as to fix the plastic tubes into the acupoints to facilitate the later cutting. This method for acupoint anatomic positioning is of low cost with accurate positioning and simple manipulation, which has advantages in strong experimental and innovative values.
Facile generation of cell microarrays using vacuum degassing and coverslip sweeping.
Wang, Min S; Luo, Zhen; Cherukuri, Sundar; Nitin, Nitin
2014-07-15
A simple method to generate cell microarrays with high-percentage well occupancy and well-defined cell confinement is presented. This method uses a synergistic combination of vacuum degassing and coverslip sweeping. The vacuum degassing step dislodges air bubbles from the microwells, which in turn enables the cells to enter the microwells, while the physical sweeping step using a glass coverslip removes the excess cells outside the microwells. This low-cost preparation method provides a simple solution to generating cell microarrays that can be performed in basic research laboratories and point-of-care settings for routine cell-based screening assays. Copyright © 2014 Elsevier Inc. All rights reserved.
Cabrera, Carlos; Chang, Lei; Stone, Mars; Busch, Michael; Wilson, David H
2015-11-01
Nucleic acid testing (NAT) has become the standard for high sensitivity in detecting low levels of virus. However, adoption of NAT can be cost prohibitive in low-resource settings where access to extreme sensitivity could be clinically advantageous for early detection of infection. We report development and preliminary validation of a simple, low-cost, fully automated digital p24 antigen immunoassay with the sensitivity of quantitative NAT viral load (NAT-VL) methods for detection of acute HIV infection. We developed an investigational 69-min immunoassay for p24 capsid protein for use on a novel digital analyzer on the basis of single-molecule-array technology. We evaluated the assay for sensitivity by dilution of standardized preparations of p24, cultured HIV, and preseroconversion samples. We characterized analytical performance and concordance with 2 NAT-VL methods and 2 contemporary p24 Ag/Ab combination immunoassays with dilutions of viral isolates and samples from the earliest stages of HIV infection. Analytical sensitivity was 0.0025 ng/L p24, equivalent to 60 HIV RNA copies/mL. The limit of quantification was 0.0076 ng/L, and imprecision across 10 runs was <10% for samples as low as 0.09 ng/L. Clinical specificity was 95.1%. Sensitivity concordance vs NAT-VL on dilutions of preseroconversion samples and Group M viral isolates was 100%. The digital immunoassay exhibited >4000-fold greater sensitivity than contemporary immunoassays for p24 and sensitivity equivalent to that of NAT methods for early detection of HIV. The data indicate that NAT-level sensitivity for acute HIV infection is possible with a simple, low-cost digital immunoassay. © 2015 American Association for Clinical Chemistry.
Optical aberrations measurement with a low cost optometric instrument
NASA Astrophysics Data System (ADS)
Furlan, Walter D.; Muñoz-Escrivá, L.; Pons, A.; Martínez-Corral, M.
2002-08-01
A simple experimental method for measuring optical aberrations of a single lens is proposed. The technique is based on the use of an optometric instrument employed for the assessment of the refractive state of the eye: the retinoscope. Experimental results for spherical aberration and astigmatism are obtained.
A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.
Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius
2017-01-01
The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.
Simple morphological control over functional diversity of SERS materials
NASA Astrophysics Data System (ADS)
Semenova, A. A.; Goodilin, E. A.
2018-03-01
Nowadays, surface-enhanced Raman spectroscopy (SERS) becomes a promising universal low-cost and real-time tool in biomedical applications, medical screening or forensic analysis allowing for detection of different molecules below nanomolar concentrations. Silver nanoparticles and nanostructures have proven to be a common choice for SERS measurements due to a tunable plasmon resonance, high stability and facile fabrication methods. However, a proper design of silver-based nanomaterials for highly sensitive SERS applications still remains a challenge. In this work, effective and simple preparation methods of various silver nanostructures are proposed and systematically developed using aqueous diamminesilver (I) hydroxide as a precursor.
Low-Cost Detection of Thin Film Stress during Fabrication
NASA Technical Reports Server (NTRS)
Nabors, Sammy A.
2015-01-01
NASA's Marshall Space Flight Center has developed a simple, cost-effective optical method for thin film stress measurements during growth and/or subsequent annealing processes. Stress arising in thin film fabrication presents production challenges for electronic devices, sensors, and optical coatings; it can lead to substrate distortion and deformation, impacting the performance of thin film products. NASA's technique measures in-situ stress using a simple, noncontact fiber optic probe in the thin film vacuum deposition chamber. This enables real-time monitoring of stress during the fabrication process and allows for efficient control of deposition process parameters. By modifying process parameters in real time during fabrication, thin film stress can be optimized or controlled, improving thin film product performance.
Niarchos, Georgios; Dubourg, Georges; Afroudakis, Georgios; Georgopoulos, Markos; Tsouti, Vasiliki; Makarona, Eleni; Crnojevic-Bengin, Vesna; Tsamis, Christos
2017-01-01
In this paper, we investigated the effect of humidity on paper substrates and propose a simple and low-cost method for their passivation using ZnO nanoparticles. To this end, we built paper-based microdevices based on an interdigitated electrode (IDE) configuration by means of a mask-less laser patterning method on simple commercial printing papers. Initial resistive measurements indicate that a paper substrate with a porous surface can be used as a cost-effective, sensitive and disposable humidity sensor in the 20% to 70% relative humidity (RH) range. Successive spin-coated layers of ZnO nanoparticles then, control the effect of humidity. Using this approach, the sensors become passive to relative humidity changes, paving the way to the development of ZnO-based gas sensors on paper substrates insensitive to humidity. PMID:28273847
Li, Zhi; Tevis, Ian D; Oyola-Reynoso, Stephanie; Newcomb, Lucas B; Halbertsma-Black, Julian; Bloch, Jean-Francis; Thuo, Martin
2015-12-01
Interest in low-cost analytical devices (especially for diagnostics) has recently increased; however, concomitant translation to the field has been slow, in part due to personnel and supply-chain challenges in resource-limited settings. Overcoming some of these challenges require the development of a method that takes advantage of locally available resources and/or skills. We report a Melt-and-mold fabrication (MnM Fab) approach to low-cost and simple devices that has the potential to be adapted locally since it requires a single material that is recyclable and simple skills to access multiple devices. We demonstrated this potential by fabricating entry level bio-analytical devices using an affordable low-melting metal alloy, Field's metal, with molds produced from known materials such as plastic (acrylonitrile-butadiene-styrene (ABS)), glass, and paper. We fabricated optical gratings then 4×4 well plates using the same recycled piece of metal. We then reconfigured the well plates into rapid prototype microfluidic devices with which we demonstrated laminar flow, droplet generation, and bubble formation from T-shaped channels. We conclude that this MnM-Fab method is capable of addressing some challenges typically encountered with device translation, such as technical know-how or material supply, and that it can be applied to other devices, as needed in the field, using a single moldable material. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhu, Tang; Cai, Chao; Duan, Chunting; Zhai, Shuai; Liang, Songmiao; Jin, Yan; Zhao, Ning; Xu, Jian
2015-07-01
A simple, rapid (10 s) and scalable method to fabricate superhydrophobic polypropylene (PP) fabrics is developed by swelling the fabrics in cyclohexane/heptane mixture at 80 °C. The recrystallization of the swollen macromolecules on the fiber surface contributes to the formation of submicron protuberances, which increase the surface roughness dramatically and result in superhydrophobic behavior. The superhydrophobic PP fabrics possess excellent repellency to blood, urine, milk, coffee, and other common liquids, and show good durability and robustness, such as remarkable resistances to water penetration, abrasion, acidic/alkaline solution, and boiling water. The excellent comprehensive performance of the superhydrophobic PP fabrics indicates their potential applications as oil/water separation materials, protective garments, diaper pads, or other medical and health supplies. This simple, fast and low cost method operating at a relatively low temperature is superior to other reported techniques for fabricating superhydrophobic PP materials as far as large scale manufacturing is considered. Moreover, the proposed method is applicable for preparing superhydrophobic PP films and sheets as well.
A facile and low-cost micro fabrication material: flash foam.
He, Yong; Xiao, Xiao; Wu, Yan; Fu, Jian-zhong
2015-08-28
Although many microfabrication methods have been reported, the preliminary replication templates used in most microfabrication still depend on the expensive and long-period photolithography. This paper explores an alternative replication templates based on a daily used material, flash foam (FF), and proposes a facile microfabrication method, flash foam stamp lithography (FFSL). When FF is exposed with a desired pattern mask, the negative of the pattern is transferred to its surface and micro structures are formed due to the shrinkage of the exposed area. As FF is commonly used in personal stamps, FFSL is very simple and cost-effective. In this paper, we demonstrated that FF is a good and low-cost template for many micro fabrication methods, such as micro casting and soft lithography. Thus, designing and fabricating micro structures at personal office immediately become possible with FFSL. Furthermore, we demonstrated that multi-scale micro structures can be easily fabricated by double exposure with FFSL. Skin textures is used as another case to demonstrate that FFSL can fabricate structures with different depth in a single exposure. As a result, FF shows a promising future in biology, and analytical chemistry, such as rapid fabrication of point of care diagnostics and microfluidic analytical devices with low cost.
Biomedical microfluidic devices by using low-cost fabrication techniques: A review.
Faustino, Vera; Catarino, Susana O; Lima, Rui; Minas, Graça
2016-07-26
One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made to develop low-cost alternatives for the fabrication of microstructures, avoiding the use of cleanroom facilities. Recently, low-cost techniques without cleanroom facilities that feature aspect ratios more than 20, for fabricating those SU-8 moulds have been gaining popularity among biomedical research community. In those techniques, Ultraviolet (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, replaces the more expensive and less available Mask Aligner that has been used in the last 15 years for SU-8 patterning. Alternatively, non-lithographic low-cost techniques, due to their ability for large-scale production, have increased the interest of the industrial and research community to develop simple, rapid and low-cost microfluidic structures. These alternative techniques include Print and Peel methods (PAP), laserjet, solid ink, cutting plotters or micromilling, that use equipment available in almost all laboratories and offices. An example is the xurography technique that uses a cutting plotter machine and adhesive vinyl films to generate the master moulds to fabricate microfluidic channels. In this review, we present a selection of the most recent lithographic and non-lithographic low-cost techniques to fabricate microfluidic structures, focused on the features and limitations of each technique. Only microfabrication methods that do not require the use of cleanrooms are considered. Additionally, potential applications of these microfluidic devices in biomedical engineering are presented with some illustrative examples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fast and economic immobilization methods described for non-commercial Pseudomonas lipases
2014-01-01
Background There is an increasing interest to seek new enzyme preparations for the development of new products derived from bioprocesses to obtain alternative bio-based materials. In this context, four non-commercial lipases from Pseudomonas species were prepared, immobilized on different low-cost supports, and examined for potential biotechnological applications. Results To reduce costs of eventual scaling-up, the new lipases were obtained directly from crude cell extracts or from growth culture supernatants, and immobilized by simple adsorption on Accurel EP100, Accurel MP1000 and Celite®545. The enzymes evaluated were LipA and LipC from Pseudomonas sp. 42A2, a thermostable mutant of LipC, and LipI.3 from Pseudomonas CR611, which were produced in either homologous or heterologous hosts. Best immobilization results were obtained on Accurel EP100 for LipA and on Accurel MP1000 for LipC and its thermostable variant. Lip I.3, requiring a refolding step, was poorly immobilized on all supports tested (best results for Accurel MP1000). To test the behavior of immobilized lipases, they were assayed in triolein transesterification, where the best results were observed for lipases immobilized on Accurel MP1000. Conclusions The suggested protocol does not require protein purification and uses crude enzymes immobilized by a fast adsorption technique on low-cost supports, which makes the method suitable for an eventual scaling up aimed at biotechnological applications. Therefore, a fast, simple and economic method for lipase preparation and immobilization has been set up. The low price of the supports tested and the simplicity of the procedure, skipping the tedious and expensive purification steps, will contribute to cost reduction in biotechnological lipase-catalyzed processes. PMID:24755191
Data Verification Tools for Minimizing Management Costs of Dense Air-Quality Monitoring Networks.
Miskell, Georgia; Salmond, Jennifer; Alavi-Shoshtari, Maryam; Bart, Mark; Ainslie, Bruce; Grange, Stuart; McKendry, Ian G; Henshaw, Geoff S; Williams, David E
2016-01-19
Aiming at minimizing the costs, both of capital expenditure and maintenance, of an extensive air-quality measurement network, we present simple statistical methods that do not require extensive training data sets for automated real-time verification of the reliability of data delivered by a spatially dense hybrid network of both low-cost and reference ozone measurement instruments. Ozone is a pollutant that has a relatively smooth spatial spread over a large scale although there can be significant small-scale variations. We take advantage of these characteristics and demonstrate detection of instrument calibration drift within a few days using a rolling 72 h comparison of hourly averaged data from the test instrument with that from suitably defined proxies. We define the required characteristics of the proxy measurements by working from a definition of the network purpose and specification, in this case reliable determination of the proportion of hourly averaged ozone measurements that are above a threshold in any given day, and detection of calibration drift of greater than ±30% in slope or ±5 parts-per-billion in offset. By analyzing results of a study of an extensive deployment of low-cost instruments in the Lower Fraser Valley, we demonstrate that proxies can be established using land-use criteria and that simple statistical comparisons can identify low-cost instruments that are not stable and therefore need replacing. We propose that a minimal set of compliant reference instruments can be used to verify the reliability of data from a much more extensive network of low-cost devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewani, Aliya A., E-mail: a.ashraf@griffith.edu.au; O’Keefe, Steven G.; Thiel, David V.
A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substratemore » thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.« less
Use of 3D Printing for Custom Wind Tunnel Fabrication
NASA Astrophysics Data System (ADS)
Gagorik, Paul; Bates, Zachary; Issakhanian, Emin
2016-11-01
Small-scale wind tunnels for the most part are fairly simple to produce with standard building equipment. However, the intricate bell housing and inlet shape of an Eiffel type wind tunnel, as well as the transition from diffuser to fan in a rectangular tunnel can present design and construction obstacles. With the help of 3D printing, these shapes can be custom designed in CAD models and printed in the lab at very low cost. The undergraduate team at Loyola Marymount University has built a custom benchtop tunnel for gas turbine film cooling experiments. 3D printing is combined with conventional construction methods to build the tunnel. 3D printing is also used to build the custom tunnel floor and interchangeable experimental pieces for various experimental shapes. This simple and low-cost tunnel is a custom solution for specific engineering experiments for gas turbine technology research.
Optically transparent frequency selective surfaces on flexible thin plastic substrates
NASA Astrophysics Data System (ADS)
Dewani, Aliya A.; O'Keefe, Steven G.; Thiel, David V.; Galehdar, Amir
2015-02-01
A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substrate thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.
Soldering to a single atomic layer
NASA Astrophysics Data System (ADS)
Girit, ćaǧlar Ö.; Zettl, A.
2007-11-01
The standard technique to make electrical contact to nanostructures is electron beam lithography. This method has several drawbacks including complexity, cost, and sample contamination. We present a simple technique to cleanly solder submicron sized, Ohmic contacts to nanostructures. To demonstrate, we contact graphene, a single atomic layer of carbon, and investigate low- and high-bias electronic transport. We set lower bounds on the current carrying capacity of graphene. A simple model allows us to obtain device characteristics such as mobility, minimum conductance, and contact resistance.
Soldering to a single atomic layer
NASA Astrophysics Data System (ADS)
Girit, Caglar; Zettl, Alex
2008-03-01
The standard technique to make electrical contact to nanostructures is electron beam lithography. This method has several drawbacks including complexity, cost, and sample contamination. We present a simple technique to cleanly solder submicron sized, Ohmic contacts to nanostructures. To demonstrate, we contact graphene, a single atomic layer of carbon, and investigate low- and high-bias electronic transport. We set lower bounds on the current carrying capacity of graphene. A simple model allows us to obtain device characteristics such as mobility, minimum conductance, and contact resistance.
NASA Astrophysics Data System (ADS)
Sayama, K.; Arai, T.
2008-02-01
Efficient solar energy conversion system for hydrogen production from water, solar-hydrogen system, is one of most important technologies for genuinely sustainable development of the society in the world wide scale. However, there are many problems to breakthrough such as low solar-to-H2 efficiency (STH), high cost, low stability, etc in order to realize the system practically and economically. The solar-hydrogen systems using semiconductors are mainly classified as follows; solar cell-electrolysis system, semiconductor photoelectrode system, and photocatalyst system. There are various merits and demerits in each system. The solar cell-electrolysis system is very efficient but is very high cost. The photocatalyst system is very simple and relatively low cost, but the efficiency is still very low. On the other hand, various semiconductor systems with high efficiency have been investigated. A high STH more than 10% was reported using non-oxide semiconductor photoelectrodes such as InGaP, while the preparation methods were costly. In a European project, some simple oxide semiconductor photoelectrodes such as Fe2O3 and WO3 are mainly studied. Here, we investigated various photoelectrodes using mixed metal oxide especially on BiVO4 semiconductor, and a high throughput screening system of new visible light responsible semiconductors for photoelectrode and photocatalyst. Moreover, photocatalysis-electrolysis hybrid system for economical H2 production is studied to overcome the demerit of photocatalyst system on the gas separation and low efficiency.
Romero, Veronica; Amaral, Joseph; Fitzpatrick, Paula; Schmidt, R C; Duncan, Amie W; Richardson, Michael J
2017-04-01
Functionally stable and robust interpersonal motor coordination has been found to play an integral role in the effectiveness of social interactions. However, the motion-tracking equipment required to record and objectively measure the dynamic limb and body movements during social interaction has been very costly, cumbersome, and impractical within a non-clinical or non-laboratory setting. Here we examined whether three low-cost motion-tracking options (Microsoft Kinect skeletal tracking of either one limb or whole body and a video-based pixel change method) can be employed to investigate social motor coordination. Of particular interest was the degree to which these low-cost methods of motion tracking could be used to capture and index the coordination dynamics that occurred between a child and an experimenter for three simple social motor coordination tasks in comparison to a more expensive, laboratory-grade motion-tracking system (i.e., a Polhemus Latus system). Overall, the results demonstrated that these low-cost systems cannot substitute the Polhemus system in some tasks. However, the lower-cost Microsoft Kinect skeletal tracking and video pixel change methods were successfully able to index differences in social motor coordination in tasks that involved larger-scale, naturalistic whole body movements, which can be cumbersome and expensive to record with a Polhemus. However, we found the Kinect to be particularly vulnerable to occlusion and the pixel change method to movements that cross the video frame midline. Therefore, particular care needs to be taken in choosing the motion-tracking system that is best suited for the particular research.
Toward an affordable and user-friendly visual motion capture system.
Bonnet, V; Sylla, N; Cherubini, A; Gonzáles, A; Azevedo Coste, C; Fraisse, P; Venture, G
2014-01-01
The present study aims at designing and evaluating a low-cost, simple and portable system for arm joint angle estimation during grasping-like motions. The system is based on a single RGB-D camera and three customized markers. The automatically detected and tracked marker positions were used as inputs to an offline inverse kinematic process based on bio-mechanical constraints to reduce noise effect and handle marker occlusion. The method was validated on 4 subjects with different motions. The joint angles were estimated both with the proposed low-cost system and, a stereophotogrammetric system. Comparative analysis shows good accuracy with high correlation coefficient (r= 0.92) and low average RMS error (3.8 deg).
A simple and low-cost permanent magnet system for NMR
NASA Astrophysics Data System (ADS)
Chonlathep, K.; Sakamoto, T.; Sugahara, K.; Kondo, Y.
2017-02-01
We have developed a simple, easy to build, and low-cost magnet system for NMR, of which homogeneity is about 4 ×10-4 at 57 mT, with a pair of two commercially available ferrite magnets. This homogeneity corresponds to about 90 Hz spectral resolution at 2.45 MHz of the hydrogen Larmor frequency. The material cost of this NMR magnet system is little more than 100. The components can be printed by a 3D printer.
A Simple Approach for Demonstrating Soil Water Retention and Field Capacity
ERIC Educational Resources Information Center
Howard, A.; Heitman, J. L.; Bowman, D.
2010-01-01
It is difficult to demonstrate the soil water retention relationship and related concepts because the specialized equipment required for performing these measurements is unavailable in most classrooms. This article outlines a low-cost, easily visualized method by which these concepts can be demonstrated in most any classroom. Columns (62.5 cm…
Construction of an Inexpensive Copper Heat-Pipe Oven
ERIC Educational Resources Information Center
Grove, T. T.; Hockensmith, W. A.; Cheviron, N.; Grieser, W.; Dill, R.; Masters, M. F.
2009-01-01
We present a new, low-cost method of building an all copper heat-pipe oven that increases the practicality of this device in advanced undergraduate instructional labs. The construction parts are available at local hardware and plumbing supply stores, and the assembly techniques employed are simple and require no machining. (Contains 1 footnote, 3…
Comparative economics of space resource utilization
NASA Technical Reports Server (NTRS)
Cutler, Andrew Hall
1991-01-01
Physical economic factors such as mass payback ratio, total payback ratio, and capital payback time are discussed and used to compare the economics of using resources from the Moon, Mars and its moons, and near Earth asteroids to serve certain near term markets such as propellant in low Earth orbit or launched mass reduction for lunar and Martian exploration. Methods for accounting for the time cost of money in simple figures of merit such as MPRs are explored and applied to comparisons such as those between lunar, Martian, and asteroidal resources. Methods for trading off capital and operating costs to compare schemes with substantially different capital to operating cost ratio are presented and discussed. Areas where further research or engineering would be extremely useful in reducing economic uncertainty are identified, as are areas where economic merit is highly sensitive to engineering performance - as well as areas where such sensitivity is surprisingly low.
Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin
2016-01-01
Purpose: The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Methods: Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Results: Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r2 > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Conclusion: Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide. PMID:27478788
Coates, Jennifer; Colaiezzi, Brooke; Fiedler, John L; Wirth, James; Lividini, Keith; Rogers, Beatrice
2012-09-01
Dietary assessment data are essential for designing, monitoring, and evaluating food fortification and other food-based nutrition programs. Planners and managers must understand the validity, usefulness, and cost tradeoffs of employing alternative dietary assessment methods, but little guidance exists. To identify and apply criteria to assess the tradeoffs of using alternative dietary methods for meeting fortification programming needs. Twenty-five semistructured expert interviews were conducted and literature was reviewed for information on the validity, usefulness, and cost of using 24-hour recalls, Food Frequency Questionnaires/Fortification Rapid Assessment Tool (FFQ/FRAT), Food Balance Sheets (FBS), and Household Consumption and Expenditures Surveys (HCES) for program stage-specific information needs. Criteria were developed and applied to construct relative rankings of the four methods. Needs assessment: HCES offers the greatest suitability at the lowest cost for estimating the risk of inadequate intakes, but relative to 24-hour recall compromises validity. HCES should be used to identify vehicles and to estimate coverage and likely impact due to its low cost and moderate-to-high validity. Baseline assessment: 24-hour recall should be applied using a representative sample. Monitoring: A simple, low-cost FFQ can be used to monitor coverage. Impact evaluation: 24-hour recall should be used to assess changes in nutrient intakes. FBS have low validity relative to other methods for all programmatic purposes. Each dietary assessment method has strengths and weaknesses that vary by context and purpose. Method selection must be driven by the program's data needs, the suitability of the methods for the purpose, and a clear understanding of the tradeoffs involved.
Cao, Ziyi; Xiao, Xiudi; Lu, Xuanming; Zhan, Yongjun; Cheng, Haoliang; Xu, Gang
2016-01-01
In this approach, the VO2 nanoparticles have been successfully fabricated via combusting the low-cost precursor solution consisted of NH4VO3, C2H6O2 and C2H5OH. By the XRD, TEM and XPS analysis, it can be found that the synthetic monoclinic VO2 is single crystal and no impurity is defined. After dispersing the VO2 nanoparticles into the polymer, the solar modulation of VO2-based composite film is up to 12.5% with luminous transmission and haze around 62.2% and 0.5%, respectively. In other words, the composite films show high performance of thermochromic properties. This could open an efficient way to fabricate low-cost and large-scale VO2 (M) nanoparticles and thermochromic films. PMID:27976748
Zheng, Hao-Bo; Ding, Jun; Zheng, Shu-Jian; Zhu, Gang-Tian; Yuan, Bi-Feng; Feng, Yu-Qi
2016-01-01
In this study, we proposed a method to fabricate magnetic carbon nitride (CN) nanosheets by simple physical blending. Low-cost CN nanosheets prepared by urea possessed a highly π-conjugated structure; therefore the obtained composites were employed as magnetic solid-phase extraction (MSPE) sorbent for extraction of polycyclic aromatic hydrocarbons (PAHs) in edible oil samples. Moreover, sample pre-treatment time could be carried out within 10 min. Thus, a simple and cheap method for the analysis of PAHs in edible oil samples was established by coupling magnetic CN nanosheets-based MSPE with gas chromatography-mass spectrometry (GC/MS) analysis. Limits of quantitation (LOQs) for eight PAHs ranged from 0.4 to 0.9 ng/g. The intra- and inter-day relative standard deviations (RSDs) were less than 15.0%. The recoveries of PAHs for spiked soybean oil samples ranged from 91.0% to 124.1%, with RSDs of less than 10.2%. Taken together, the proposed method offers a simple and cost-effective option for the convenient analysis of PAHs in oil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin
2016-06-01
The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r(2) > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide.
NASA Astrophysics Data System (ADS)
Nurulain, S.; Manap, H.
2017-09-01
This paper describes about a visible light transmission (VLT) measurement system using an optical method. VLT rate plays an important role in order to determine the visibility of a medium. Current instrument to measure visibility has a gigantic set up, costly and mostly fails to function at low light condition environment. This research focuses on the development of a VLT measurement system using a simple experimental set-up and at a low cost. An open path optical technique is used to measure a few series of known-VLT thin film that act as sample of different visibilities. This measurement system is able to measure the light intensity of these thin films within the visible light region (535-540 nm) and the response time is less than 1s.
A simple and low-cost permanent magnet system for NMR.
Chonlathep, K; Sakamoto, T; Sugahara, K; Kondo, Y
2017-02-01
We have developed a simple, easy to build, and low-cost magnet system for NMR, of which homogeneity is about 4×10 -4 at 57mT, with a pair of two commercially available ferrite magnets. This homogeneity corresponds to about 90Hz spectral resolution at 2.45MHz of the hydrogen Larmor frequency. The material cost of this NMR magnet system is little more than $100. The components can be printed by a 3D printer. Copyright © 2016 Elsevier Inc. All rights reserved.
Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet
NASA Technical Reports Server (NTRS)
Baker, Paul; Repaci, Max; Sames, David
1998-01-01
Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.
ERIC Educational Resources Information Center
Chen, Huai-Yi; Nieh, Hwa-Ming; Yang, Ming-Feng; Chou, Yu-Kung; Chung, Jui-Hsu; Liou, Je-Wen
2016-01-01
This study proposes a home-assembled, low-cost blue light-emitting diode (LED) photometer that uses simple and low-cost hardware and software, costing about US $150. This 425-nm wavelength photometer is controlled by an 89C51 microcontroller chip. Glucose concentration detection experiments involving enzyme coupling reactions were carried out to…
Capacitance Sensor For Nondestructive Determination Of Total Oil Content In Nuts
USDA-ARS?s Scientific Manuscript database
Earlier a simple, low cost instrument was designed and assembled in our laboratory, that could estimate the moisture content (MC) of in-shell peanuts (MC range 9% to 20%) and yellow-dent field corn (MC range 7% to 18%). In this method a sample of of in-shell peanuts or corn was placed between a set...
Nano-soldering to single atomic layer
Girit, Caglar O [Berkeley, CA; Zettl, Alexander K [Kensington, CA
2011-10-11
A simple technique to solder submicron sized, ohmic contacts to nanostructures has been disclosed. The technique has several advantages over standard electron beam lithography methods, which are complex, costly, and can contaminate samples. To demonstrate the soldering technique graphene, a single atomic layer of carbon, has been contacted, and low- and high-field electronic transport properties have been measured.
LIGHT-SABRE enables efficient in-magnet catalytic hyperpolarization
NASA Astrophysics Data System (ADS)
Theis, Thomas; Truong, Milton; Coffey, Aaron M.; Chekmenev, Eduard Y.; Warren, Warren S.
2014-11-01
Nuclear spin hyperpolarization overcomes the sensitivity limitations of traditional NMR and MRI, but the most general method demonstrated to date (dynamic nuclear polarization) has significant limitations in scalability, cost, and complex apparatus design. As an alternative, signal amplification by reversible exchange (SABRE) of parahydrogen on transition metal catalysts can hyperpolarize a variety of substrates, but to date this scheme has required transfer of the sample to low magnetic field or very strong RF irradiation. Here we demonstrate "Low-Irradiation Generation of High Tesla-SABRE" (LIGHT-SABRE) which works with simple pulse sequences and low power deposition; it should be usable at any magnetic field and for hyperpolarization of many different nuclei. This approach could drastically reduce the cost and complexity of producing hyperpolarized molecules.
A facile and low-cost micro fabrication material: flash foam
He, Yong; Xiao, Xiao; Wu, Yan; Fu, Jian-zhong
2015-01-01
Although many microfabrication methods have been reported, the preliminary replication templates used in most microfabrication still depend on the expensive and long-period photolithography. This paper explores an alternative replication templates based on a daily used material, flash foam (FF), and proposes a facile microfabrication method, flash foam stamp lithography (FFSL). When FF is exposed with a desired pattern mask, the negative of the pattern is transferred to its surface and micro structures are formed due to the shrinkage of the exposed area. As FF is commonly used in personal stamps, FFSL is very simple and cost-effective. In this paper, we demonstrated that FF is a good and low-cost template for many micro fabrication methods, such as micro casting and soft lithography. Thus, designing and fabricating micro structures at personal office immediately become possible with FFSL. Furthermore, we demonstrated that multi-scale micro structures can be easily fabricated by double exposure with FFSL. Skin textures is used as another case to demonstrate that FFSL can fabricate structures with different depth in a single exposure. As a result, FF shows a promising future in biology, and analytical chemistry, such as rapid fabrication of point of care diagnostics and microfluidic analytical devices with low cost. PMID:26314247
Xiong, Jin-Feng; Li, Jian-Xiao; Mo, Guang-Zhen; Huo, Jing-Pei; Liu, Jin-Yan; Chen, Xiao-Yun; Wang, Zhao-Yang
2014-12-05
1,3,5-Tri(1H-benzo[d]imidazol-2-yl)benzene derivatives, as a new kind of fluorescent chemosensor for the detection of nitroaromatic explosives, are designed and synthesized by simple N-hydrocarbylation. Among 16 obtained compounds, compound 4g has the best capability for detection of picric acid (PA), having good selectivity and high sensitivity. The detection of PA with 4g solution-coated paper strips at the picogram level is developed. A simple, portable, and low-cost method is provided for detecting PA in solution and contact mode.
Tian, Kun; Siegel, Gene; Tiwari, Ashutosh
2017-02-01
The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Ming; Zhang, Jingjing; Jiang, Jie; Zhang, Jing; Gao, Jing; Qiao, Xiaolin
2014-04-07
In this paper, a novel approach based on paper spray ionization coupled with ion mobility spectrometry (PSI-IMS) was developed for rapid, in situ detection of cocaine residues in liquid samples and on various surfaces (e.g. glass, marble, skin, wood, fingernails), without tedious sample pretreatment. The obvious advantages of PSI are its low cost, easy operation and simple configuration without using nebulizing gas or discharge gas. Compared with mass spectrometry, ion mobility spectrometry (IMS) takes advantage of its low cost, easy operation, and simple configuration without requiring a vacuum system. Therefore, IMS is a more congruous detection method for PSI in the case of rapid, in situ analysis. For the analysis of cocaine residues in liquid samples, dynamic responses from 5 μg mL(-1) to 200 μg mL(-1) with a linear coefficient (R(2)) of 0.992 were obtained. In this case, the limit of detection (LOD) was calculated to be 2 μg mL(-1) as signal to noise (S/N) was 3 with a relative standard deviation (RSD) of 6.5% for 11 measurements (n = 11). Cocaine residues on various surfaces such as metal, glass, marble, wood, skin, and fingernails were also directly analyzed before wiping the surfaces with a piece of paper. The LOD was calculated to be as low as 5 ng (S/N = 3, RSD = 6.3%, n = 11). This demonstrates the capability of the PSI-IMS method for direct detection of cocaine residues at scenes of cocaine administration. Our results show that PSI-IMS is a simple, sensitive, rapid and economical method for in situ detection of this illicit drug, which could help governments to combat drug abuse.
Ljungberg, Elinor M; Carlsson, Katarina Steen; Dahlin, Lars B
2008-01-01
Background Health-care costs for hand and forearm injuries in young children are poorly documented. We examined costs in 533 children injured years 1996–2003. Methods Health-care costs and costs for lost productivity were retrospectively calculated in children from three catchment areas in Sweden. Seven case categories corresponding to alternative prevention strategies were constructed. Results Over time, diminishing number of ward days reduced the health-care cost per case. Among children, the cost of lost productivity due to parental leave was 14 percent of total cost. Fingertip injuries had low median costs but high total costs due to their frequency. Complex injuries by machine or rifle had high costs per case, and despite a low number of cases, total cost was high. Type of injury, surgery and physiotherapy sessions were associated with variations in health-care cost. Low age and ethnic background had a significant effect on number of ward days. Conclusion The costs per hand injury for children were lower compared to adults due to both lower health-care costs and to the fact that parents had comparatively short periods of absence from work. Frequent simple fingertip injuries and rare complex injuries induce high costs for society. Such costs should be related to costs for prevention of these injuries. PMID:18606018
Measurement and classification of heart and lung sounds by using LabView for educational use.
Altrabsheh, B
2010-01-01
This study presents the design, development and implementation of a simple low-cost method of phonocardiography signal detection. Human heart and lung signals are detected by using a simple microphone through a personal computer; the signals are recorded and analysed using LabView software. Amplitude and frequency analyses are carried out for various phonocardiography pathological cases. Methods for automatic classification of normal and abnormal heart sounds, murmurs and lung sounds are presented. Various cases of heart and lung sound measurement are recorded and analysed. The measurements can be saved for further analysis. The method in this study can be used by doctors as a detection tool aid and may be useful for teaching purposes at medical and nursing schools.
Low cost sensing technology for type 2 diabetes monitoring
NASA Astrophysics Data System (ADS)
Sarswat, Prashant; Free, Michael
2015-03-01
Alpha-hydroxybutyrate (2-hydroxybutyrate or α-HB) is becoming more widely recognized as an important metabolic biomarker that has been shown to be highly correlated with prediabetes and other metabolic diseases. In 2012 there were 86 million Americans with prediabetes, many of whom are not aware they have prediabetes, but could be diagnosed and treated to prevent type 2 diabetes if a simple, low-cost, convenient test were available. We have developed new, low-cost, accurate α-HB detection methods that can be used for the detection and monitoring of diseases such as prediabetes, type 2 diabetes, β-cell dysfunction, and early hyperglycemia. The new sensing method utilizes a diol recognition moiety, additives and a photoinitiator to detect α-HB at levels near 1 micro g/l in the presence of serum compounds such as lactic acid, sodium pyruvate, and glucose. The objective of this research is to improve the understanding of the interactions that enhance α-HB detection to enable additional improvements in α-HB detection as well as improvements in other biosensor applications.
Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents.
Zimmermann, Stefan; Barth, Sebastian; Baether, Wolfgang K M; Ringer, Joachim
2008-09-01
Ion mobility spectrometry (IMS) is a well-known method for detecting hazardous compounds in air. Typical applications are the detection of chemical warfare agents, highly toxic industrial compounds, explosives, and drugs of abuse. Detection limits in the low part per billion range, fast response times, and simple instrumentation make this technique more and more popular. In particular, there is an increasing demand for miniaturized low-cost IMS for hand-held devices and air monitoring of public areas by sensor networks. In this paper, we present a miniaturized aspiration condenser type ion mobility spectrometer for fast detection of chemical warfare agents. The device is easy to manufacture and allows single substance identification down to low part per billion-level concentrations within seconds. The improved separation power results from ion focusing by means of geometric constraints and fluid dynamics. A simple pattern recognition algorithm is used for the identification of trained substances in air. The device was tested at the German Armed Forces Scientific Institute for Protection Technologies-NBC-Protection. Different chemical warfare agents, such as sarin, tabun, soman, US-VX, sulfur mustard, nitrogen mustard, and lewisite were tested. The results are presented here.
Ohshima, Chihiro; Takahashi, Hajime; Phraephaisarn, Chirapiphat; Vesaratchavest, Mongkol; Keeratipibul, Suwimon; Kuda, Takashi; Kimura, Bon
2014-01-01
Listeria monocytogenes is the causative bacteria of listeriosis, which has a higher mortality rate than that of other causes of food poisoning. Listeria spp., of which L. monocytogenes is a member, have been isolated from food and manufacturing environments. Several methods have been published for identifying Listeria spp.; however, many of the methods cannot identify newly categorized Listeria spp. Additionally, they are often not suitable for the food industry, owing to their complexity, cost, or time consumption. Recently, high-resolution melting analysis (HRMA), which exploits DNA-sequence differences, has received attention as a simple and quick genomic typing method. In the present study, a new method for the simple, rapid, and low-cost identification of Listeria spp. has been presented using the genes rarA and ldh as targets for HRMA. DNA sequences of 9 Listeria species were first compared, and polymorphisms were identified for each species for primer design. Species specificity of each HRM curve pattern was estimated using type strains of all the species. Among the 9 species, 7 were identified by HRMA using rarA gene, including 3 new species. The remaining 2 species were identified by HRMA of ldh gene. The newly developed HRMA method was then used to assess Listeria isolates from the food industry, and the method efficiency was compared to that of identification by 16S rDNA sequence analysis. The 2 methods were in coherence for 92.6% of the samples, demonstrating the high accuracy of HRMA. The time required for identifying Listeria spp. was substantially low, and the process was considerably simplified, providing a useful and precise method for processing multiple samples per day. Our newly developed method for identifying Listeria spp. is highly valuable; its use is not limited to the food industry, and it can be used for the isolates from the natural environment.
Ohshima, Chihiro; Takahashi, Hajime; Phraephaisarn, Chirapiphat; Vesaratchavest, Mongkol; Keeratipibul, Suwimon; Kuda, Takashi; Kimura, Bon
2014-01-01
Listeria monocytogenes is the causative bacteria of listeriosis, which has a higher mortality rate than that of other causes of food poisoning. Listeria spp., of which L. monocytogenes is a member, have been isolated from food and manufacturing environments. Several methods have been published for identifying Listeria spp.; however, many of the methods cannot identify newly categorized Listeria spp. Additionally, they are often not suitable for the food industry, owing to their complexity, cost, or time consumption. Recently, high-resolution melting analysis (HRMA), which exploits DNA-sequence differences, has received attention as a simple and quick genomic typing method. In the present study, a new method for the simple, rapid, and low-cost identification of Listeria spp. has been presented using the genes rarA and ldh as targets for HRMA. DNA sequences of 9 Listeria species were first compared, and polymorphisms were identified for each species for primer design. Species specificity of each HRM curve pattern was estimated using type strains of all the species. Among the 9 species, 7 were identified by HRMA using rarA gene, including 3 new species. The remaining 2 species were identified by HRMA of ldh gene. The newly developed HRMA method was then used to assess Listeria isolates from the food industry, and the method efficiency was compared to that of identification by 16S rDNA sequence analysis. The 2 methods were in coherence for 92.6% of the samples, demonstrating the high accuracy of HRMA. The time required for identifying Listeria spp. was substantially low, and the process was considerably simplified, providing a useful and precise method for processing multiple samples per day. Our newly developed method for identifying Listeria spp. is highly valuable; its use is not limited to the food industry, and it can be used for the isolates from the natural environment. PMID:24918440
The State of the World's Children, 1985.
ERIC Educational Resources Information Center
Grant, James P.
In the last 2 years, the State of the World's Children report has drawn worldwide attention to the fact that four simple and low-cost methods could enable parents to halve the rate of child deaths and child disability in the developing world. Part I of this year's statement reports on the progress of these strategies in different parts of the…
Vial OrganicTM-Organic Chemistry Labs for High School and Junior College
NASA Astrophysics Data System (ADS)
Russo, Thomas J.; Meszaros, Mark
1999-01-01
Vial Organic is the most economical, safe, and time-effective method of performing organic chemistry experiments. Activities are carried out in low-cost, sealed vials. Vial Organic is extremely safe because only micro quantities of reactants are used, reactants are contained in tightly sealed vials, and only water baths are used for temperature control. Vial Organic laboratory activities are easily performed within one 50-minute class period. When heat is required, a simple hot-water bath is prepared from a beaker of water and an inexpensive immersion heater. The low cost, ease of use, and relatively short time requirement will allow organic chemistry to be experienced by more students with less confusion and intimidation.
Low cost voice compression for mobile digital radios
NASA Technical Reports Server (NTRS)
Omura, J. K.
1985-01-01
A new technique for low cost rubust voice compression at 4800 bits per second was studied. The approach was based on using a cascade of digital biquad adaptive filters with simplified multipulse excitation followed by simple bit sequence compression.
Low-cost Volumetric Ultrasound by Augmentation of 2D Systems: Design and Prototype.
Herickhoff, Carl D; Morgan, Matthew R; Broder, Joshua S; Dahl, Jeremy J
2018-01-01
Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.
LIGHT-SABRE enables efficient in-magnet catalytic hyperpolarization.
Theis, Thomas; Truong, Milton; Coffey, Aaron M; Chekmenev, Eduard Y; Warren, Warren S
2014-11-01
Nuclear spin hyperpolarization overcomes the sensitivity limitations of traditional NMR and MRI, but the most general method demonstrated to date (dynamic nuclear polarization) has significant limitations in scalability, cost, and complex apparatus design. As an alternative, signal amplification by reversible exchange (SABRE) of parahydrogen on transition metal catalysts can hyperpolarize a variety of substrates, but to date this scheme has required transfer of the sample to low magnetic field or very strong RF irradiation. Here we demonstrate "Low-Irradiation Generation of High Tesla-SABRE" (LIGHT-SABRE) which works with simple pulse sequences and low power deposition; it should be usable at any magnetic field and for hyperpolarization of many different nuclei. This approach could drastically reduce the cost and complexity of producing hyperpolarized molecules. Copyright © 2014 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Lowe, N. K., Ed.
This document provides technical information and simple instructions for constructing 84 different pieces of science equipment. Each entry includes: (1) name of item; (2) purpose of the equipment; (3) person who submitted the information; (4) line drawing of prototype; (5) list of low-cost materials needed; (6) construction procedures; (7)…
Cotton fabric-based electrochemical device for lactate measurement in saliva.
Malon, Radha S P; Chua, K Y; Wicaksono, Dedy H B; Córcoles, Emma P
2014-06-21
Lactate measurement is vital in clinical diagnostics especially among trauma and sepsis patients. In recent years, it has been shown that saliva samples are an excellent applicable alternative for non-invasive measurement of lactate. In this study, we describe a method for the determination of lactate concentration in saliva samples by using a simple and low-cost cotton fabric-based electrochemical device (FED). The device was fabricated using template method for patterning the electrodes and wax-patterning technique for creating the sample placement/reaction zone. Lactate oxidase (LOx) enzyme was immobilised at the reaction zone using a simple entrapment method. The LOx enzymatic reaction product, hydrogen peroxide (H2O2) was measured using chronoamperometric measurements at the optimal detection potential (-0.2 V vs. Ag/AgCl), in which the device exhibited a linear working range between 0.1 to 5 mM, sensitivity (slope) of 0.3169 μA mM(-1) and detection limit of 0.3 mM. The low detection limit and wide linear range were suitable to measure salivary lactate (SL) concentration, thus saliva samples obtained under fasting conditions and after meals were evaluated using the FED. The measured SL varied among subjects and increased after meals randomly. The proposed device provides a suitable analytical alternative for rapid and non-invasive determination of lactate in saliva samples. The device can also be adapted to a variety of other assays that requires simplicity, low-cost, portability and flexibility.
Fabrication of wafer-scale nanopatterned sapphire substrate through phase separation lithography
NASA Astrophysics Data System (ADS)
Guo, Xu; Ni, Mengyang; Zhuang, Zhe; Dai, Jiangping; Wu, Feixiang; Cui, Yushuang; Yuan, Changsheng; Ge, Haixiong; Chen, Yanfeng
2016-04-01
A phase separation lithography (PSL) based on polymer blend provides an extremely simple, low-cost, and high-throughput way to fabricate wafer-scale disordered nanopatterns. This method was introduced to fabricate nanopatterned sapphire substrates (NPSSs) for GaN-based light-emitting diodes (LEDs). The PSL process only involved in spin-coating of polystyrene (PS)/polyethylene glycol (PEG) polymer blend on sapphire substrate and followed by a development with deionized water to remove PEG moiety. The PS nanoporous network was facilely obtained, and the structural parameters could be effectively tuned by controlling the PS/PEG weight ratio of the spin-coating solution. 2-in. wafer-scale NPSSs were conveniently achieved through the PS nanoporous network in combination with traditional nanofabrication methods, such as O2 reactive ion etching (RIE), e-beam evaporation deposition, liftoff, and chlorine-based RIE. In order to investigate the performance of such NPSSs, typical blue LEDs with emission wavelengths of ~450 nm were grown on the NPSS and a flat sapphire substrate (FSS) by metal-organic chemical vapor deposition, respectively. The integral photoluminescence (PL) intensity of the NPSS LED was enhanced by 32.3 % compared to that of the FSS-LED. The low relative standard deviation of 4.7 % for PL mappings of NPSS LED indicated the high uniformity of PL data across the whole 2-in. wafer. Extremely simple, low cost, and high throughput of the process and the ability to fabricate at the wafer scale make PSL a potential method for production of nanopatterned sapphire substrates.
Mikaeili, F; Kia, E B; Sharbatkhori, M; Sharifdini, M; Jalalizand, N; Heidari, Z; Zarei, Z; Stensvold, C R; Mirhendi, H
2013-06-01
Six simple methods for extraction of ribosomal and mitochondrial DNA from Toxocara canis, Toxocara cati and Toxascaris leonina were compared by evaluating the presence, appearance and intensity of PCR products visualized on agarose gels and amplified from DNA extracted by each of the methods. For each species, two isolates were obtained from the intestines of their respective hosts: T. canis and T. leonina from dogs, and T. cati from cats. For all isolates, total DNA was extracted using six different methods, including grinding, boiling, crushing, beating, freeze-thawing and the use of a commercial kit. To evaluate the efficacy of each method, the internal transcribed spacer (ITS) region and the cytochrome c oxidase subunit 1 (cox1) gene were chosen as representative markers for ribosomal and mitochondrial DNA, respectively. Among the six DNA extraction methods, the beating method was the most cost effective for all three species, followed by the commercial kit. Both methods produced high intensity bands on agarose gels and were characterized by no or minimal smear formation, depending on gene target; however, beating was less expensive. We therefore recommend the beating method for studies where costs need to be kept at low levels. Copyright © 2013 Elsevier Inc. All rights reserved.
2018-01-01
Use of additive manufacturing is growing rapidly in the orthotics field. This technology allows orthotics to be designed directly on digital scans of limbs. However, little information is available about scanners and 3D scans. The aim of this study is to look at the agreement between manual measurements, high-level and low-cost handheld 3D scanners. We took two manual measurements and three 3D scans with each scanner from 14 lower limbs. The lower limbs were divided into 17 sections of 30mm each from 180mm above the mid-patella to 300mm below. Time to record and to process the three 3D scans for scanners methods were compared with Student t-test while Bland-Altman plots were used to study agreement between circumferences of each section from the three methods. The record time was 97s shorter with high-level scanner than with the low-cost (p = .02) while the process time was nine times quicker with the low-cost scanner (p < .01). An overestimation of 2.5mm was found in high-level scanner compared to manual measurement, but with a better repeatability between measurements. The low-cost scanner tended to overestimate the circumferences from 0.1% to 1.5%, overestimation being greater for smaller circumferences. In conclusion, 3D scanners provide more information about the shape of the lower limb, but the reliability depends on the 3D scanner and the size of the scanned segment. Low-cost scanners could be useful for clinicians because of the simple and fast process, but attention should be focused on accuracy, which depends on the scanned body segment. PMID:29320560
Dessery, Yoann; Pallari, Jari
2018-01-01
Use of additive manufacturing is growing rapidly in the orthotics field. This technology allows orthotics to be designed directly on digital scans of limbs. However, little information is available about scanners and 3D scans. The aim of this study is to look at the agreement between manual measurements, high-level and low-cost handheld 3D scanners. We took two manual measurements and three 3D scans with each scanner from 14 lower limbs. The lower limbs were divided into 17 sections of 30mm each from 180mm above the mid-patella to 300mm below. Time to record and to process the three 3D scans for scanners methods were compared with Student t-test while Bland-Altman plots were used to study agreement between circumferences of each section from the three methods. The record time was 97s shorter with high-level scanner than with the low-cost (p = .02) while the process time was nine times quicker with the low-cost scanner (p < .01). An overestimation of 2.5mm was found in high-level scanner compared to manual measurement, but with a better repeatability between measurements. The low-cost scanner tended to overestimate the circumferences from 0.1% to 1.5%, overestimation being greater for smaller circumferences. In conclusion, 3D scanners provide more information about the shape of the lower limb, but the reliability depends on the 3D scanner and the size of the scanned segment. Low-cost scanners could be useful for clinicians because of the simple and fast process, but attention should be focused on accuracy, which depends on the scanned body segment.
Dykes, Patricia C; Wantland, Dean; Whittenburg, Luann; Lipsitz, Stuart; Saba, Virginia K
2013-01-01
While nursing activities represent a significant proportion of inpatient care, there are no reliable methods for determining nursing costs based on the actual services provided by the nursing staff. Capture of data to support accurate measurement and reporting on the cost of nursing services is fundamental to effective resource utilization. Adopting standard terminologies that support tracking both the quality and the cost of care could reduce the data entry burden on direct care providers. This pilot study evaluated the feasibility of using a standardized nursing terminology, the Clinical Care Classification System (CCC), for developing a reliable costing method for nursing services. Two different approaches are explored; the Relative Value Unit RVU and the simple cost-to-time methods. We found that the simple cost-to-time method was more accurate and more transparent in its derivation than the RVU method and may support a more consistent and reliable approach for costing nursing services.
NASA Astrophysics Data System (ADS)
Zhen, Fangchen; Ran, Maofei; Chu, Wei; Jiang, Chengfa; Sun, Wenjing
2018-03-01
Pd-Fe3O4 hybrid nanostructures were prepared using a simple one-pot hydrothermal method. The prepared materials were characterized by Fourier transform-infrared spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, transmission electron microscopy, inductively coupled plasma, N2 adsorption-desorption, and vibrating sample magnetometry. This self-assembled nanosystem acted as an efficient magnetically recyclable noble metal-based multi-functional nanocatalyst. It showed excellent catalytic activity and stability for the Heck reaction of iodobenzene and styrene under mild conditions. The methods used to prepare the Pd-Fe3O4 catalysts were simple and low-cost, which will be useful for the large-scale development and application of a magnetically recoverable Pd catalyst.
NASA Astrophysics Data System (ADS)
Gabai, Haniel; Baranes-Zeevi, Maya; Zilberman, Meital; Shaked, Natan T.
2013-04-01
We propose an off-axis interferometric imaging system as a simple and unique modality for continuous, non-contact and non-invasive wide-field imaging and characterization of drug release from its polymeric device used in biomedicine. In contrast to the current gold-standard methods in this field, usually based on chromatographic and spectroscopic techniques, our method requires no user intervention during the experiment, and only one test-tube is prepared. We experimentally demonstrate imaging and characterization of drug release from soy-based protein matrix, used as skin equivalent for wound dressing with controlled anesthetic, Bupivacaine drug release. Our preliminary results demonstrate the high potential of our method as a simple and low-cost modality for wide-field imaging and characterization of drug release from drug delivery devices.
Frugal Biotech Applications of Low-Temperature Plasma.
Machala, Zdenko; Graves, David B
2018-06-01
Gas discharge low-temperature air plasma can be utilized for a variety of applications, including biomedical, at low cost. We term these applications 'frugal plasma' - an example of frugal innovation. We demonstrate how simple, robust, low-cost frugal plasma devices can be used to safely disinfect instruments, surfaces, and water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Luo, Shu; Luo, Yufeng; Wu, Hengcai; Li, Mengya; Yan, Lingjia; Jiang, Kaili; Liu, Liang; Li, Qunqing; Fan, Shoushan; Wang, Jiaping
2017-01-01
Macroscopic and 3D superaligned CNT (SACNT) sponges are fabricated through a simple, low-cost, controllable, and scalable self-assembly method without using organic binder. Sponges with specific shapes and densities can be achieved. SACNT sponges are ultralight (1-50 mg cm -3 ), highly porous (97.5%-99.9%) with honeycomb-like hierarchical structure, and highly conductive. Using SACNT sponges as templates, various materials with honeycomb-like structure can be obtained for wide applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wireless sensor networks for heritage object deformation detection and tracking algorithm.
Xie, Zhijun; Huang, Guangyan; Zarei, Roozbeh; He, Jing; Zhang, Yanchun; Ye, Hongwu
2014-10-31
Deformation is the direct cause of heritage object collapse. It is significant to monitor and signal the early warnings of the deformation of heritage objects. However, traditional heritage object monitoring methods only roughly monitor a simple-shaped heritage object as a whole, but cannot monitor complicated heritage objects, which may have a large number of surfaces inside and outside. Wireless sensor networks, comprising many small-sized, low-cost, low-power intelligent sensor nodes, are more useful to detect the deformation of every small part of the heritage objects. Wireless sensor networks need an effective mechanism to reduce both the communication costs and energy consumption in order to monitor the heritage objects in real time. In this paper, we provide an effective heritage object deformation detection and tracking method using wireless sensor networks (EffeHDDT). In EffeHDDT, we discover a connected core set of sensor nodes to reduce the communication cost for transmitting and collecting the data of the sensor networks. Particularly, we propose a heritage object boundary detecting and tracking mechanism. Both theoretical analysis and experimental results demonstrate that our EffeHDDT method outperforms the existing methods in terms of network traffic and the precision of the deformation detection.
Wireless Sensor Networks for Heritage Object Deformation Detection and Tracking Algorithm
Xie, Zhijun; Huang, Guangyan; Zarei, Roozbeh; He, Jing; Zhang, Yanchun; Ye, Hongwu
2014-01-01
Deformation is the direct cause of heritage object collapse. It is significant to monitor and signal the early warnings of the deformation of heritage objects. However, traditional heritage object monitoring methods only roughly monitor a simple-shaped heritage object as a whole, but cannot monitor complicated heritage objects, which may have a large number of surfaces inside and outside. Wireless sensor networks, comprising many small-sized, low-cost, low-power intelligent sensor nodes, are more useful to detect the deformation of every small part of the heritage objects. Wireless sensor networks need an effective mechanism to reduce both the communication costs and energy consumption in order to monitor the heritage objects in real time. In this paper, we provide an effective heritage object deformation detection and tracking method using wireless sensor networks (EffeHDDT). In EffeHDDT, we discover a connected core set of sensor nodes to reduce the communication cost for transmitting and collecting the data of the sensor networks. Particularly, we propose a heritage object boundary detecting and tracking mechanism. Both theoretical analysis and experimental results demonstrate that our EffeHDDT method outperforms the existing methods in terms of network traffic and the precision of the deformation detection. PMID:25365458
Basilico, Nicoletta; Cortelezzi, Lucia; Serpellini, Chiara; Taramelli, Donatella; Omodeo-Salè, Fausta; Salè, Fausta
2009-02-15
We provide two simple low-cost and low-tech procedures to measure with good precision and accuracy the binding and internalization into human erythrocytes of chloroquine and other aminoquinolines. The methods are based on the high fluorescence of the quinoline ring and are complementary. Method A evaluates residual drugs in the supernatants of treated erythrocytes, whereas method B quantifies the total uptake by whole cells and the fraction bound to the membranes. Drug uptake is dose dependent and related to the number of erythrocytes. These assays could be useful when studying the cell interaction of quinoline-type compounds not available in the radioactive form.
ERIC Educational Resources Information Center
Ayed, Ahmad; Eqtait, Faeda; Harazneh, Lubna; Fashafsheh, Imad; Nazzal, Sewar; Talahmeh, Bian; Hajar, Deena; Awawdeh, Rrawan
2015-01-01
Background: Breast self-examination is a simple, very low cost, noninvasive with no special material/tool requirements; and it is an effective diagnostic method for breast cancer which only takes five minutes to apply. Aim of the Study: The study aimed to assess the level of BSE knowledge, attitude, and practice among female nursing students in…
An overland flow sampler for use in vegetative filters
D. Eisenhauer; M. Helmers; J. Brothers; M. Dosskey; T. Franti; A. Boldt; B. Strahm
2002-01-01
Vegetative filters (VF) are used to remove contaminants from agricultural runoff and improve surface water quality. Techniques are needed to quantify the performance of VF in realistic field settings. The goal of this project was to develop and test a relatively simple and low cost method for sampling overland flow in a VF. The 0.3 m wide sampler has the capacity to...
ERIC Educational Resources Information Center
Gold, J.; Aitken, C. K.; Dixon, H. G.; Lim, M. S. C.; Gouillou, M.; Spelman, T.; Wakefield, M.; Hellard, M. E.
2011-01-01
Mobile phone text messages (SMS) are a promising method of health promotion, but a simple and low cost way to obtain phone numbers is required to reach a wide population. We conducted a randomised controlled trial with simultaneous brief interventions to (i) evaluate effectiveness of messages related to safer sex and sun safety and (ii) pilot the…
Tabata, Ryo; Kamiya, Takehiro; Shigenobu, Shuji; Yamaguchi, Katsushi; Yamada, Masashi; Hasebe, Mitsuyasu; Fujiwara, Toru; Sawa, Shinichiro
2013-01-01
Next-generation sequencing (NGS) technologies enable the rapid production of an enormous quantity of sequence data. These powerful new technologies allow the identification of mutations by whole-genome sequencing. However, most reported NGS-based mapping methods, which are based on bulked segregant analysis, are costly and laborious. To address these limitations, we designed a versatile NGS-based mapping method that consists of a combination of low- to medium-coverage multiplex SOLiD (Sequencing by Oligonucleotide Ligation and Detection) and classical genetic rough mapping. Using only low to medium coverage reduces the SOLiD sequencing costs and, since just 10 to 20 mutant F2 plants are required for rough mapping, the operation is simple enough to handle in a laboratory with limited space and funding. As a proof of principle, we successfully applied this method to identify the CTR1, which is involved in boron-mediated root development, from among a population of high boron requiring Arabidopsis thaliana mutants. Our work demonstrates that this NGS-based mapping method is a moderately priced and versatile method that can readily be applied to other model organisms. PMID:23104114
Oda, Hitomi; Miyauchi, Akira; Ito, Yasuhiro; Sasai, Hisanori; Masuoka, Hiroo; Yabuta, Tomonori; Fukushima, Mitsuhiro; Higashiyama, Takuya; Kihara, Minoru; Kobayashi, Kaoru; Miya, Akihiro
2017-01-30
The incidence of thyroid cancer is increasing rapidly in many countries, resulting in rising societal costs of the care of thyroid cancer. We reported that the active surveillance of low-risk papillary microcarcinoma had less unfavorable events than immediate surgery, while the oncological outcomes of these managements were similarly excellent. Here we calculated the medical costs of these two managements. We created a model of the flow of these managements, based on our previous study. The flow and costs include the step of diagnosis, surgery, prescription of medicine, recurrence, salvage surgery for recurrence, and care for 10 years after the diagnosis. The costs were calculated according to the typical clinical practices at Kuma Hospital performed under the Japanese Health Care Insurance System. If conversion surgeries were not considered, the 'simple cost' of active surveillance for 10 years was 167,780 yen/patient. If there were no recurrences, the 'simple cost' of immediate surgery was calculated as 794,770 yen/patient to 1,086,070 yen/patient, depending on the type of surgery and postoperative medication. The 'simple cost' of surgery was 4.7 to 6.5 times the 'simple cost' of surveillance. When conversion surgeries and recurrence were considered, the 'total cost' of active surveillance for 10 years became 225,695 yen/patient. When recurrence were considered, the 'total cost' of immediate surgery was 928,094 yen/patient, which was 4.1 times the 'total cost' of the active surveillance. At Kuma Hospital in Japan, the 10-year total cost of immediate surgery was 4.1 times expensive than active surveillance.
Enhanced Sintering of β"-Al2O3/YSZ with the Sintering Aids of TiO2 and MnO2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Xiaochuan; Li, Guosheng; Kim, Jin Yong
2015-07-11
β"-Al2O3 has been the dominated choice for the electrolyte materials of sodium batteries because of its high ionic conductivity, excellent stability with the electrode materials, satisfactory mechanical strength, and low material cost. To achieve adequate electrical and mechanical performance, sintering of β"-Al2O3 is typically carried out at temperatures above 1600oC with deliberate efforts on controlling the phase, composition, and microstructure. Here, we reported a simple method to fabricate β"-Al2O3/YSZ electrolyte at relatively lower temperatures. With the starting material of boehmite, single phase of β"-Al2O3 can be achieved at as low as 1200oC. It was found that TiO2 was extremely effectivemore » as a sintering aid for the densification of β"-Al2O3 and similar behavior was observed with MnO2 for YSZ. With the addition of 2 mol% TiO2 and 5 mol% MnO2, the β"-Al2O3/YSZ composite was able to be densified at as low as 1400oC with a fine microstructure and good electrical/mechanical performance. This study demonstrated a new approach of synthesis and sintering of β"-Al2O3/YSZ composite, which represented a simple and low-cost method for fabrication of high-performance β"-Al2O3/YSZ electrolyte.« less
Gujral, Rajinder Singh; Haque, Sk Manirul
2010-01-01
A simple and sensitive UV spectrophotometric method was developed and validated for the simultaneous determination of Potassium Clavulanate (PC) and Amoxicillin Trihydrate (AT) in bulk, pharmaceutical formulations and in human urine samples. The method was linear in the range of 0.2–8.5 μg/ml for PC and 6.4–33.6 μg/ml for AT. The absorbance was measured at 205 and 271 nm for PC and AT respectively. The method was validated with respect to accuracy, precision, specificity, ruggedness, robustness, limit of detection and limit of quantitation. This method was used successfully for the quality assessment of four PC and AT drug products and in human urine samples with good precision and accuracy. This is found to be simple, specific, precise, accurate, reproducible and low cost UV Spectrophotometric method. PMID:23675211
Well water quality in rural Nicaragua using a low-cost bacterial test and microbial source tracking.
Weiss, Patricia; Aw, Tiong Gim; Urquhart, Gerald R; Galeano, Miguel Ruiz; Rose, Joan B
2016-04-01
Water-related diseases, particularly diarrhea, are major contributors to morbidity and mortality in developing countries. Monitoring water quality on a global scale is crucial to making progress in terms of population health. Traditional analytical methods are difficult to use in many regions of the world in low-resource settings that face severe water quality issues due to the inaccessibility of laboratories. This study aimed to evaluate a new low-cost method (the compartment bag test (CBT)) in rural Nicaragua. The CBT was used to quantify the presence of Escherichia coli in drinking water wells and aimed to determine the source(s) of any microbial contamination. Results indicate that the CBT is a viable method for use in remote rural regions. The overall quality of well water in Pueblo Nuevo, Nicaragua was deemed unsafe, and results led to the conclusion that animal fecal wastes may be one of the leading causes of well contamination. Elevation and depth of wells were not found to impact overall water quality. However rope-pump wells had a 64.1% reduction in contamination when compared with simple wells.
A simple and low-cost biofilm quantification method using LED and CMOS image sensor.
Kwak, Yeon Hwa; Lee, Junhee; Lee, Junghoon; Kwak, Soo Hwan; Oh, Sangwoo; Paek, Se-Hwan; Ha, Un-Hwan; Seo, Sungkyu
2014-12-01
A novel biofilm detection platform, which consists of a cost-effective red, green, and blue light-emitting diode (RGB LED) as a light source and a lens-free CMOS image sensor as a detector, is designed. This system can measure the diffraction patterns of cells from their shadow images, and gather light absorbance information according to the concentration of biofilms through a simple image processing procedure. Compared to a bulky and expensive commercial spectrophotometer, this platform can provide accurate and reproducible biofilm concentration detection and is simple, compact, and inexpensive. Biofilms originating from various bacterial strains, including Pseudomonas aeruginosa (P. aeruginosa), were tested to demonstrate the efficacy of this new biofilm detection approach. The results were compared with the results obtained from a commercial spectrophotometer. To utilize a cost-effective light source (i.e., an LED) for biofilm detection, the illumination conditions were optimized. For accurate and reproducible biofilm detection, a simple, custom-coded image processing algorithm was developed and applied to a five-megapixel CMOS image sensor, which is a cost-effective detector. The concentration of biofilms formed by P. aeruginosa was detected and quantified by varying the indole concentration, and the results were compared with the results obtained from a commercial spectrophotometer. The correlation value of the results from those two systems was 0.981 (N = 9, P < 0.01) and the coefficients of variation (CVs) were approximately threefold lower at the CMOS image-sensor platform. Copyright © 2014 Elsevier B.V. All rights reserved.
Norrgard, E B; Sitaraman, N; Barry, J F; McCarron, D J; Steinecker, M H; DeMille, D
2016-05-01
We demonstrate a simple and easy method for producing low-reflectivity surfaces that are ultra-high vacuum compatible, may be baked to high temperatures, and are easily applied even on complex surface geometries. Black cupric oxide (CuO) surfaces are chemically grown in minutes on any copper surface, allowing for low-cost, rapid prototyping, and production. The reflective properties are measured to be comparable to commercially available products for creating optically black surfaces. We describe a vacuum apparatus which uses multiple blackened copper surfaces for sensitive, low-background detection of molecules using laser-induced fluorescence.
NASA Astrophysics Data System (ADS)
Yang, Qiming; Duan, Jialong; Yang, Wen; Li, Xueming; Mo, Jinghui; Yang, Peizhi; Tang, Qunwei
2018-03-01
Pursuit of low-cost and large-scale method to prepare carbon quantum dots (CQDs) is a persistent objective in recent years. In this work, we have successfully synthesized a series of nitrogen-doped carbon quantum dots (N-CQDs) under different hydrothermal temperature employing Eichhornia crassipes (ECs) as precursors. Considering the pollution ability to water and low-cost, this study may direct the novel path to convert waste material to useful quantum dots. After measurements such as TEM, XRD, Raman, XPS, PL as well as the UV-vis absorbance ability, outstanding optical properties have been discovered. In this fashion, solar cells are tentative to be fabricated, yielding the maximized solar-to-electrical conversion efficiency of 0.17% with a good fill factor of 67%. Meanwhile, the above-mentioned quantum dots also show the up-conversion ability, suggesting the potential application in infrared detection or broadening light-absorbing devices.
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
2015-01-01
Bacterial meningitis is a serious health concern worldwide. Given that meningitis can be fatal and many meningitis cases occurred in high-poverty areas, a simple, low-cost, highly sensitive method is in great need for immediate and early diagnosis of meningitis. Herein, we report a versatile and cost-effective polydimethylsiloxane (PDMS)/paper hybrid microfluidic device integrated with loop-mediated isothermal amplification (LAMP) for the rapid, sensitive, and instrument-free detection of the main meningitis-causing bacteria, Neisseria meningitidis (N. meningitidis). The introduction of paper into the microfluidic device for LAMP reactions enables stable test results over a much longer period of time than a paper-free microfluidic system. This hybrid system also offers versatile functions, by providing not only on-site qualitative diagnostic analysis (i.e., a yes or no answer), but also confirmatory testing and quantitative analysis in laboratory settings. The limit of detection of N. meningitidis is about 3 copies per LAMP zone within 45 min, close to single-bacterium detection sensitivity. In addition, we have achieved simple pathogenic microorganism detection without a laborious sample preparation process and without the use of centrifuges. This low-cost hybrid microfluidic system provides a simple and highly sensitive approach for fast instrument-free diagnosis of N. meningitidis in resource-limited settings. This versatile PDMS/paper microfluidic platform has great potential for the point of care (POC) diagnosis of a wide range of infectious diseases, especially for developing nations. PMID:25019330
A cost assessment of reliability requirements for shuttle-recoverable experiments
NASA Technical Reports Server (NTRS)
Campbell, J. W.
1975-01-01
The relaunching of unsuccessful experiments or satellites will become a real option with the advent of the space shuttle. An examination was made of the cost effectiveness of relaxing reliability requirements for experiment hardware by allowing more than one flight of an experiment in the event of its failure. Any desired overall reliability or probability of mission success can be acquired by launching an experiment with less reliability two or more times if necessary. Although this procedure leads to uncertainty in total cost projections, because the number of flights is not known in advance, a considerable cost reduction can sometimes be achieved. In cases where reflight costs are low relative to the experiment's cost, three flights with overall reliability 0.9 can be made for less than half the cost of one flight with a reliability of 0.9. An example typical of shuttle payload cost projections is cited where three low reliability flights would cost less than $50 million and a single high reliability flight would cost over $100 million. The ratio of reflight cost to experiment cost is varied and its effect on the range in total cost is observed. An optimum design reliability selection criterion to minimize expected cost is proposed, and a simple graphical method of determining this reliability is demonstrated.
Brack, Paul; Dann, Sandie; Wijayantha, K. G. Upul; Adcock, Paul; Foster, Simon
2016-01-01
There is a growing research interest in the development of portable systems which can deliver hydrogen on-demand to proton exchange membrane (PEM) hydrogen fuel cells. Researchers seeking to develop such systems require a method of measuring the generated hydrogen. Herein, we describe a simple, low-cost, and robust method to measure the hydrogen generated from the reaction of solids with aqueous solutions. The reactions are conducted in a conventional one-necked round-bottomed flask placed in a temperature controlled water bath. The hydrogen generated from the reaction in the flask is channeled through tubing into a water-filled inverted measuring cylinder. The water displaced from the measuring cylinder by the incoming gas is diverted into a beaker on a balance. The balance is connected to a computer, and the change in the mass reading of the balance over time is recorded using data collection and spreadsheet software programs. The data can then be approximately corrected for water vapor using the method described herein, and parameters such as the total hydrogen yield, the hydrogen generation rate, and the induction period can also be deduced. The size of the measuring cylinder and the resolution of the balance can be changed to adapt the setup to different hydrogen volumes and flow rates. PMID:27584581
Natural precursor based hydrothermal synthesis of sodium carbide for reactor applications
NASA Astrophysics Data System (ADS)
Swapna, M. S.; Saritha Devi, H. V.; Sebastian, Riya; Ambadas, G.; Sankararaman, S.
2017-12-01
Carbides are a class of materials with high mechanical strength and refractory nature which finds a wide range of applications in industries and nuclear reactors. The existing synthesis methods of all types of carbides have problems in terms of use of toxic chemical precursors, high-cost, etc. Sodium carbide (Na2C2) which is an alkali metal carbide is the least explored one and also that there is no report of low-cost and low-temperature synthesis of sodium carbide using the eco-friendly, easily available natural precursors. In the present work, we report a simple low-cost, non-toxic hydrothermal synthesis of refractory sodium carbide using the natural precursor—Pandanus. The formation of sodium carbide along with boron carbide is evidenced by the structural and morphological characterizations. The sample thus synthesized is subjected to field emission scanning electron microscopy (FESEM), x-ray powder diffraction (XRD), ultraviolet (UV)—visible spectroscopy, Fourier transform infrared spectroscopy (FTIR), Raman, and photoluminescent (PL) spectroscopic techniques.
A Low-Cost and Energy-Efficient Multiprocessor System-on-Chip for UWB MAC Layer
NASA Astrophysics Data System (ADS)
Xiao, Hao; Isshiki, Tsuyoshi; Khan, Arif Ullah; Li, Dongju; Kunieda, Hiroaki; Nakase, Yuko; Kimura, Sadahiro
Ultra-wideband (UWB) technology has attracted much attention recently due to its high data rate and low emission power. Its media access control (MAC) protocol, WiMedia MAC, promises a lot of facilities for high-speed and high-quality wireless communication. However, these benefits in turn involve a large amount of computational load, which challenges the traditional uniprocessor architecture based implementation method to provide the required performance. However, the constrained cost and power budget, on the other hand, makes using commercial multiprocessor solutions unrealistic. In this paper, a low-cost and energy-efficient multiprocessor system-on-chip (MPSoC), which tackles at once the aspects of system design, software migration and hardware architecture, is presented for the implementation of UWB MAC layer. Experimental results show that the proposed MPSoC, based on four simple RISC processors and shared-memory infrastructure, achieves up to 45% performance improvement and 65% power saving, but takes 15% less area than the uniprocessor implementation.
Low-cost oblique illumination: an image quality assessment.
Ruiz-Santaquiteria, Jesus; Espinosa-Aranda, Jose Luis; Deniz, Oscar; Sanchez, Carlos; Borrego-Ramos, Maria; Blanco, Saul; Cristobal, Gabriel; Bueno, Gloria
2018-01-01
We study the effectiveness of several low-cost oblique illumination filters to improve overall image quality, in comparison with standard bright field imaging. For this purpose, a dataset composed of 3360 diatom images belonging to 21 taxa was acquired. Subjective and objective image quality assessments were done. The subjective evaluation was performed by a group of diatom experts by psychophysical test where resolution, focus, and contrast were assessed. Moreover, some objective nonreference image quality metrics were applied to the same image dataset to complete the study, together with the calculation of several texture features to analyze the effect of these filters in terms of textural properties. Both image quality evaluation methods, subjective and objective, showed better results for images acquired using these illumination filters in comparison with the no filtered image. These promising results confirm that this kind of illumination filters can be a practical way to improve the image quality, thanks to the simple and low cost of the design and manufacturing process. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Sarenqiqige; Maeda, Akihiro; Yoshimura, Kazuhisa
2014-01-01
A sensitive, simple and low-cost determination method for the total iron concentration in boiler water systems of power generation plants was developed by solid phase spectrometry (SPS) using 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ) as a coloring agent. The reagents and 0.08 cm(3) of a cation exchanger were added to a 50-cm(3) boiler water sample, then mixed for 30 min to adsorb/concentrate the produced Fe(TPTZ)2(2+) colored complex on the solid beads, resulting in a 625 times concentration of the target analyte without any other procedure. The detection limit of 0.1 μg dm(-3) was obtained, and the optimum conditions for the digestion procedure and color developing reaction was investigated and reported. According to the application of this method to real samples, the present SPS method is the best one because of the shorter analysis time, simpler operation and use of very low-cost equipment compared to the conventional methods, such as TPTZ solution spectrophotometric method after a 16 times concentration, ICP-MS and AAS.
A paper-based cantilever array sensor: Monitoring volatile organic compounds with naked eye.
Fraiwan, Arwa; Lee, Hankeun; Choi, Seokheun
2016-09-01
Volatile organic compound (VOC) detection is critical for controlling industrial and commercial emissions, environmental monitoring, and public health. Simple, portable, rapid and low-cost VOC sensing platforms offer the benefits of on-site and real-time monitoring anytime and anywhere. The best and most practically useful approaches to monitoring would include equipment-free and power-free detection by the naked eye. In this work, we created a novel, paper-based cantilever sensor array that allows simple and rapid naked-eye VOC detection without the need for power, electronics or readout interface/equipment. This simple VOC detection method was achieved using (i) low-cost paper materials as a substrate and (ii) swellable thin polymers adhered to the paper. Upon exposure to VOCs, the polymer swelling adhered to the paper-based cantilever, inducing mechanical deflection that generated a distinctive composite pattern of the deflection angles for a specific VOC. The angle is directly measured by the naked eye on a 3-D protractor printed on a paper facing the cantilevers. The generated angle patterns are subjected to statistical algorithms (linear discriminant analysis (LDA)) to classify each VOC sample and selectively detect a VOC. We classified four VOC samples with 100% accuracy using LDA. Copyright © 2016 Elsevier B.V. All rights reserved.
Noviodunum Roman Fortress. a Survey on a City Wall Section
NASA Astrophysics Data System (ADS)
Teodor, A.; Teodor, E. S.; Florea, M. S.; Popescu, M. A.
2011-09-01
The paper presents in detail the method used to acquire 2D and 3D representations for the Large Tower of the Roman fortress from Noviodunum (Isaccea, Tulcea County). The available implements were a total station, a digital camera and some software for handling data. The method is not new by any rate, but well fitted to the aims - recording archaeological data on ruined but massif walls, with rough surfaces - and with a limited budget. Lately considered as a low cost procedure, laser scanning is still costly and rare in some East-European countries. Our method, as simple as it is, provides reliable data as a 3D survey, along texture details, at the lowest price, on unfinished fieldwork, preserving and picturing a stage of knowledge about the site and the architectural bodies.
How Might the Ares V Change the Need for Future Mirror Technology
NASA Technical Reports Server (NTRS)
Stahl, H. Philip
2008-01-01
More Massive Missions do not need to be More Expensive. Simple, robust, low-risk, high-TRL mission is likely to be low cost. It is also likely to be more massive than a complex, high-risk, low TRL mission. The challenge will be to overcome human nature. Launch Date Constrained Missions Cost Less
Frischer, Robert; Penhaker, Marek; Krejcar, Ondrej; Kacerovsky, Marian; Selamat, Ali
2014-01-01
Precise temperature measurement is essential in a wide range of applications in the medical environment, however the regarding the problem of temperature measurement inside a simple incubator, neither a simple nor a low cost solution have been proposed yet. Given that standard temperature sensors don't satisfy the necessary expectations, the problem is not measuring temperature, but rather achieving the desired sensitivity. In response, this paper introduces a novel hardware design as well as the implementation that increases measurement sensitivity in defined temperature intervals at low cost. PMID:25494352
Oral exfoliative cytology as a rapid diagnostic tool for paracoccidioidomycosis.
Talhari, Carolina; de Souza, João Vicente Braga; Parreira, Vilmar José; Reinel, Dieter; Talhari, Sinésio
2008-03-01
Paracoccidioidomycosis is a common deep mycosis in South America. It is caused by the dimorphic fungus Paracoccidioides brasiliensis. We report a case of a 47-year-old Brazilian man with oral lesions due to paracoccidioidomycosis, which was diagnosed by exfoliative cytology without any special staining. We highlight this diagnostic tool as a simple, low-cost, painless, non-invasive and fast method for the diagnosis of paracoccidioidomycosis.
Nicholas, Phil; Pittson, Robin; Hart, John P
2018-02-15
This paper describes the development of a simple, low cost chronoamperometric assay, for the measurement of fructose, using a graphite-nanoparticle modified screen-printed electrode (SPCE-G-COOH). Cyclic voltammetry showed that the response of the SPCE-G-COOH enhanced the sensitivity and precision, towards the enzymatically generated ferrocyanide species, over a plain SPCE; therefore the former was employed in subsequent studies. Calibration studies were carried out using chronoamperometry with a 40µl mixture containing fructose, mediator and FDH, deposited onto the SPCE-G-COOH. The response was linear from 0.1mM to 1.0mM. A commercial fruit juice sample was analysed using the developed assay and the fructose concentration was calculated to be 477mM with a precision of 3.03% (n=5). Following fortification (477mM fructose) the mean recovery was found to be 97.12% with a coefficient of variation of 6.42% (n=5); consequently, the method holds promise for the analysis of commercial fruit juices. Copyright © 2017 Elsevier Ltd. All rights reserved.
A piezo-ring-on-chip microfluidic device for simple and low-cost mass spectrometry interfacing.
Tsao, Chia-Wen; Lei, I-Chao; Chen, Pi-Yu; Yang, Yu-Liang
2018-02-12
Mass spectrometry (MS) interfacing technology provides the means for incorporating microfluidic processing with post MS analysis. In this study, we propose a simple piezo-ring-on-chip microfluidic device for the controlled spraying of MALDI-MS targets. This device uses a low-cost, commercially-available ring-shaped piezoelectric acoustic atomizer (piezo-ring) directly integrated into a polydimethylsiloxane microfluidic device to spray the sample onto the MS target substrate. The piezo-ring-on-chip microfluidic device's design, fabrication, and actuation, and its pulsatile pumping effects were evaluated. The spraying performance was examined by depositing organic matrix samples onto the MS target substrate by using both an automatic linear motion motor, and manual deposition. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was performed to analyze the peptide samples on the MALDI target substrates. Using our technique, model peptides with 10 -6 M concentration can be successfully detected. The results also indicate that the piezo-ring-on-chip approach forms finer matrix crystals and presents better MS signal uniformity with little sample consumption compared to the conventional pipetting method.
Facile fabrication of CNT-based chemical sensor operating at room temperature
NASA Astrophysics Data System (ADS)
Sheng, Jiadong; Zeng, Xian; Zhu, Qi; Yang, Zhaohui; Zhang, Xiaohua
2017-12-01
This paper describes a simple, low cost and effective route to fabricate CNT-based chemical sensors, which operate at room temperature. Firstly, the incorporation of silk fibroin in vertically aligned CNT arrays (CNTA) obtained through a thermal chemical vapor deposition (CVD) method makes the direct removal of CNT arrays from substrates without any rigorous acid or sonication treatment feasible. Through a simple one-step in situ polymerization of anilines, the functionalization of CNT arrays with polyaniline (PANI) significantly improves the sensing performance of CNT-based chemical sensors in detecting ammonia (NH3) and hydrogen chloride (HCl) vapors. Chemically modified CNT arrays also show responses to organic vapors like menthol, ethyl acetate and acetone. Although the detection limits of chemically modified CNT-based chemical sensors are of the same orders of magnitudes reported in previous studies, these CNT-based chemical sensors show advantages of simplicity, low cost and energy efficiency in preparation and fabrication of devices. Additionally, a linear relationship between the relative sensitivity and concentration of analyte makes precise estimations on the concentrations of trace chemical vapors possible.
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays
NASA Astrophysics Data System (ADS)
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-01
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications. Electronic supplementary information (ESI) available: Experimental procedures and analytical data are provided. See DOI: 10.1039/c5nr00697j
Phase-unwrapping algorithm by a rounding-least-squares approach
NASA Astrophysics Data System (ADS)
Juarez-Salazar, Rigoberto; Robledo-Sanchez, Carlos; Guerrero-Sanchez, Fermin
2014-02-01
A simple and efficient phase-unwrapping algorithm based on a rounding procedure and a global least-squares minimization is proposed. Instead of processing the gradient of the wrapped phase, this algorithm operates over the gradient of the phase jumps by a robust and noniterative scheme. Thus, the residue-spreading and over-smoothing effects are reduced. The algorithm's performance is compared with four well-known phase-unwrapping methods: minimum cost network flow (MCNF), fast Fourier transform (FFT), quality-guided, and branch-cut. A computer simulation and experimental results show that the proposed algorithm reaches a high-accuracy level than the MCNF method by a low-computing time similar to the FFT phase-unwrapping method. Moreover, since the proposed algorithm is simple, fast, and user-free, it could be used in metrological interferometric and fringe-projection automatic real-time applications.
Use of a Tea Infuser to Submerge Low-Density Dry Ice
ERIC Educational Resources Information Center
Fictorie, Carl P.; Vitz, Ed
2004-01-01
A simple tea infuser is obtained and been used as a container for the dry ice to simulate the effect from high-density dry ice. The tea infuser is a simple, low cost device to allow instructors with access to dry ice makers to effectively use the interesting demonstration.
ERIC Educational Resources Information Center
Mawire, A.
2012-01-01
A simple low-cost experiment for undergraduate students to determine the characteristics of a negative temperature coefficient of resistance thermistor is presented. The experiment measures the resistance-temperature and voltage-temperature characteristics of the thermistor. Results of the resistance-temperature experiment are used to determine…
Laser Speckle Photography: Some Simple Experiments for the Undergraduate Laboratory.
ERIC Educational Resources Information Center
Bates, B.; And Others
1986-01-01
Describes simple speckle photography experiments which are easy to set up and require only low cost standard laboratory equipment. Included are procedures for taking single, double, and multiple exposures. (JN)
Technology in rural transportation: "Simple Solutions"
DOT National Transportation Integrated Search
1997-10-01
The Rural Outreach Project: Simple Solutions Report contains the findings of a research effort aimed at identifying and describing proven, cost-effective, low-tech solutions for rural transportation-related problems or needs. Through a process ...
Rebouças, Camila Tavares; Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes
2018-05-18
Background: A green analytical chemistry method was developed for quantification of enrofloxacin in tablets. The drug, a second-generation fluoroquinolone, was first introduced in veterinary medicine for the treatment of various bacterial species. Objective: This study proposed to develop, validate, and apply a reliable, low-cost, fast, and simple IR spectroscopy method for quantitative routine determination of enrofloxacin in tablets. Methods: The method was completely validated according to the International Conference on Harmonisation guidelines, showing accuracy, precision, selectivity, robustness, and linearity. Results: It was linear over the concentration range of 1.0-3.0 mg with correlation coefficients >0.9999 and LOD and LOQ of 0.12 and 0.36 mg, respectively. Conclusions: Now that this IR method has met performance qualifications, it can be adopted and applied for the analysis of enrofloxacin tablets for production process control. The validated method can also be utilized to quantify enrofloxacin in tablets and thus is an environmentally friendly alternative for the routine analysis of enrofloxacin in quality control. Highlights: A new green method for the quantitative analysis of enrofloxacin by Fourier-Transform Infrared spectroscopy was validated. It is a fast, clean and low-cost alternative for the evaluation of enrofloxacin tablets.
Paiva, Joana S.; Dias, Duarte
2017-01-01
In recent years, safer and more reliable biometric methods have been developed. Apart from the need for enhanced security, the media and entertainment sectors have also been applying biometrics in the emerging market of user-adaptable objects/systems to make these systems more user-friendly. However, the complexity of some state-of-the-art biometric systems (e.g., iris recognition) or their high false rejection rate (e.g., fingerprint recognition) is neither compatible with the simple hardware architecture required by reduced-size devices nor the new trend of implementing smart objects within the dynamic market of the Internet of Things (IoT). It was recently shown that an individual can be recognized by extracting features from their electrocardiogram (ECG). However, most current ECG-based biometric algorithms are computationally demanding and/or rely on relatively large (several seconds) ECG samples, which are incompatible with the aforementioned application fields. Here, we present a computationally low-cost method (patent pending), including simple mathematical operations, for identifying a person using only three ECG morphology-based characteristics from a single heartbeat. The algorithm was trained/tested using ECG signals of different duration from the Physionet database on more than 60 different training/test datasets. The proposed method achieved maximal averaged accuracy of 97.450% in distinguishing each subject from a ten-subject set and false acceptance and rejection rates (FAR and FRR) of 5.710±1.900% and 3.440±1.980%, respectively, placing Beat-ID in a very competitive position in terms of the FRR/FAR among state-of-the-art methods. Furthermore, the proposed method can identify a person using an average of 1.020 heartbeats. It therefore has FRR/FAR behavior similar to obtaining a fingerprint, yet it is simpler and requires less expensive hardware. This method targets low-computational/energy-cost scenarios, such as tiny wearable devices (e.g., a smart object that automatically adapts its configuration to the user). A hardware proof-of-concept implementation is presented as an annex to this paper. PMID:28719614
Paiva, Joana S; Dias, Duarte; Cunha, João P S
2017-01-01
In recent years, safer and more reliable biometric methods have been developed. Apart from the need for enhanced security, the media and entertainment sectors have also been applying biometrics in the emerging market of user-adaptable objects/systems to make these systems more user-friendly. However, the complexity of some state-of-the-art biometric systems (e.g., iris recognition) or their high false rejection rate (e.g., fingerprint recognition) is neither compatible with the simple hardware architecture required by reduced-size devices nor the new trend of implementing smart objects within the dynamic market of the Internet of Things (IoT). It was recently shown that an individual can be recognized by extracting features from their electrocardiogram (ECG). However, most current ECG-based biometric algorithms are computationally demanding and/or rely on relatively large (several seconds) ECG samples, which are incompatible with the aforementioned application fields. Here, we present a computationally low-cost method (patent pending), including simple mathematical operations, for identifying a person using only three ECG morphology-based characteristics from a single heartbeat. The algorithm was trained/tested using ECG signals of different duration from the Physionet database on more than 60 different training/test datasets. The proposed method achieved maximal averaged accuracy of 97.450% in distinguishing each subject from a ten-subject set and false acceptance and rejection rates (FAR and FRR) of 5.710±1.900% and 3.440±1.980%, respectively, placing Beat-ID in a very competitive position in terms of the FRR/FAR among state-of-the-art methods. Furthermore, the proposed method can identify a person using an average of 1.020 heartbeats. It therefore has FRR/FAR behavior similar to obtaining a fingerprint, yet it is simpler and requires less expensive hardware. This method targets low-computational/energy-cost scenarios, such as tiny wearable devices (e.g., a smart object that automatically adapts its configuration to the user). A hardware proof-of-concept implementation is presented as an annex to this paper.
Egypt`s first remotely controlled subsea completion -- A Gulf of Suez case history
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Hawary, A.; Hoffman, J.G.
1995-11-01
A case history of the Gulf of Suez Petroleum Company`s (GUPCO) first remotely controlled subsea completion is provided. The first completion was for well GS 373-2, a previously drilled and tested exploration well located in the south portion of the Gulf of Suez. Subsea technology was utilized to economically justify development of this one well marginal field which was discovered in 1978. Traditional methods proved to be too costly for development, therefore application of a low cost subsea tree was utilized to capture the resources. In the Gulf of Suez many fields have been discovered by have not been developedmore » due to low reserves. These marginal projects can have a profound impact on the revenue and shareholder value if any economic method is used to exploit these opportunities. Platform installation was not feasible due to reserve size, hence the well has remained abandoned until recently. Capturing the experience of Amoco in the Gulf of Mexico and in the Dutch North Sea, GUPCO was able to build a low cost subsea system which would allow for the economic development of the marginal fields discovered in the past. This paper presents a summarized look at subsea completion technology. The cost comparison of traditional development methods will be made, given the local cost structure in Egypt. The application of this technology has some limitations and constraints which will be discussed in the paper. Furthermore the actual field installation of Egypt`s first remotely controlled subsea tree will be summarized. Also included is a discussion on simple remote controls,and offshore installation operations.« less
3D imaging of optically cleared tissue using a simplified CLARITY method and on-chip microscopy
Zhang, Yibo; Shin, Yoonjung; Sung, Kevin; Yang, Sam; Chen, Harrison; Wang, Hongda; Teng, Da; Rivenson, Yair; Kulkarni, Rajan P.; Ozcan, Aydogan
2017-01-01
High-throughput sectioning and optical imaging of tissue samples using traditional immunohistochemical techniques can be costly and inaccessible in resource-limited areas. We demonstrate three-dimensional (3D) imaging and phenotyping in optically transparent tissue using lens-free holographic on-chip microscopy as a low-cost, simple, and high-throughput alternative to conventional approaches. The tissue sample is passively cleared using a simplified CLARITY method and stained using 3,3′-diaminobenzidine to target cells of interest, enabling bright-field optical imaging and 3D sectioning of thick samples. The lens-free computational microscope uses pixel super-resolution and multi-height phase recovery algorithms to digitally refocus throughout the cleared tissue and obtain a 3D stack of complex-valued images of the sample, containing both phase and amplitude information. We optimized the tissue-clearing and imaging system by finding the optimal illumination wavelength, tissue thickness, sample preparation parameters, and the number of heights of the lens-free image acquisition and implemented a sparsity-based denoising algorithm to maximize the imaging volume and minimize the amount of the acquired data while also preserving the contrast-to-noise ratio of the reconstructed images. As a proof of concept, we achieved 3D imaging of neurons in a 200-μm-thick cleared mouse brain tissue over a wide field of view of 20.5 mm2. The lens-free microscope also achieved more than an order-of-magnitude reduction in raw data compared to a conventional scanning optical microscope imaging the same sample volume. Being low cost, simple, high-throughput, and data-efficient, we believe that this CLARITY-enabled computational tissue imaging technique could find numerous applications in biomedical diagnosis and research in low-resource settings. PMID:28819645
A simple approach for large-area fabrication of Ag nanorings
NASA Astrophysics Data System (ADS)
Yuan, Zhi-hao; Zhou, Wei; Duan, Yue-qin; Bie, Li-jian
2008-02-01
A simple and low-cost method based on a two-step heat treatment of AgNO3/SiO2 film has been developed for fabricating metal Ag nanoring arrays. The as-prepared nanorings have an inner diameter of 70-250 nm and an average wall thickness (namely wire diameter) of approximately 30 nm with a number density of approximately 109 cm-2 on the surface of the SiO2 matrix. X-ray diffraction (XRD) results reveal that these nanorings exhibit a face-centered cubic crystal structure. Furthermore, a new growth mechanism, namely a molten metal bubble as a self-template, is tentatively proposed for Ag nanorings.
Non-Asbestos Insulation Testing Using a Plasma Torch
NASA Technical Reports Server (NTRS)
Morgan, R. E.; Prince, A. S.; Selvidge, S. A.; Phelps, J.; Martin, C. L.; Lawrence, T. W.
2000-01-01
Insulation obsolescence issues are a major concern for the Reusable Solid Rocket Motor (RSRM). As old sources of raw materials disappear, new sources must be found and qualified. No simple, inexpensive test presently exists for predicting the erosion performance of a candidate insulation in the full-scale motor, Large motor tests cost million of dollars and therefore can only be used on a few very select candidates. There is a need for a simple, low cost method of screening insulation performance that can simulate some of the different erosion environments found in the RSRM. This paper describes a series of erosion tests on two different non-asbestos insulation formulations, a KEVLAR(registered) fiber-filled and a carbon fiber-filled insulation containing Ethylene-Propylene-Diene Monomer (EPDM) rubber as the binder. The test instrument was a plasma torch device. The two main variables investigated were heat flux and alumina particle impingement concentration. Statistical analysis revealed that the two different formulations had very different responses to the main variable. The results of this work indicate that there may be fundamental differences in how these insulation formulations perform in the motor operating environment. The plasma torch appears to offer a low-cost means of obtaining a fundamental understanding of insulation response to critical factors in a series of statistically designed experiments.
A Simple and Efficient Method of Extracting DNA from Aged Bones and Teeth.
Liu, Qiqi; Liu, Liyan; Zhang, Minli; Zhang, Qingzhen; Wang, Qiong; Ding, Xiaoran; Shao, Liting; Zhou, Zhe; Wang, Shengqi
2018-05-01
DNA is often difficult to extract from old bones and teeth due to low levels of DNA and high levels of degradation. This study established a simple yet efficient method for extracting DNA from 20 aged bones and teeth (approximately 60 years old). Based on the concentration and STR typing results, the new method of DNA extraction (OM) developed in this study was compared with the PrepFiler™ BTA Forensic DNA Extraction Kit (BM). The total amount of DNA extracted using the OM method was not significantly different from that extracted using the commercial kit (p > 0.05). However, the number of STR loci detected was significantly higher in the samples processed using the OM method than using the BM method (p < 0.05). This study aimed to establish a DNA extraction method for aged bones and teeth to improve the detection rate of STR typing and reduce costs compared to the BM technique. © 2017 American Academy of Forensic Sciences.
Development of longitudinally excited CO2 laser
NASA Astrophysics Data System (ADS)
Masroon, N. S.; Tanaka, M.; Tei, M.; Uno, K.; Tsuyama, M.; Nakano, H.
2018-05-01
Simple, compact, and affordable discharged-pumped CO2 laser controlled by a fast high voltage solid state switch has been developed. In this study, longitudinal excitation scheme has been adapted for simple configuration. In the longitudinal excitation scheme, the discharge is produced along the direction of the laser axis, and the electrodes are well separated with a small discharge cross-section. Triggered spark gap switch is usually used to switch out the high voltage because of simple and low cost. However, the triggered spark gap operates in the arc mode and suffer from recovery problem causing a short life time and low efficiency for high repetition rate operation. As a result, there is now considerable interest in replacing triggered spark gap switch with solid state switches. Solid state switches have significant advantages compared to triggered spark gap switch which include longer service lifetime, low cost and stable high trigger pulse. We have developed simple and low cost fast high voltage solid state switch that consists of series connected-MOSFETs. It has been installed to the longitudinally excited CO2 laser to realize the gap switch less operation. Characteristics of laser oscillation by varying the discharge length, charging voltage, capacitance and gas pressure have been evaluated. Longer discharge length produce high power of laser oscillation. Optimum charging voltage and gas pressure were existed for longitudinally excited CO2 laser.
Rispoli, Thaiane; Martins de Castro, Simone; Grandi, Tarciana; Prado, Mayara; Filippon, Letícia; Dornelles da Silva, Cláudia Maria; Vargas, José Eduardo; Rossetti, Lucia Maria Rosa
2018-05-03
Cystic fibrosis newborn screening was implemented in Brazil by the Public Health System in 2012. Because of cost, only 1 mutation was tested - p.Phe508del. We developed a robust low-cost genetic test for screening 11 CFTR gene mutations with potential use in developing countries. Copyright © 2018 Elsevier Inc. All rights reserved.
Successful and stable orthodontic camouflage of a mandibular asymmetry with sliding jigs.
Oliveira, Dauro Douglas; Oliveira, Bruno Franco de; Mordente, Carolina Morsani; Godoy, Gabriela Martins; Soares, Rodrigo Villamarim; Seraidarian, Paulo Isaías
2018-03-12
The purpose of this paper is to present and discuss a simple and low-cost clinical approach to correct an asymmetric skeletal Class III combined to an extensive dental open bite that significantly compromised the occlusal function and smile aesthetics of an adult male patient. The patient did not accept the idealistic surgical-orthodontic treatment option, neither the use of temporary anchorage devices to facilitate the camouflage of the asymmetrical skeletal Class III/open bite. Therefore, a very simple and inexpensive biomechanical approach using sliding jigs in the mandibular arch was implemented as the compensatory treatment of the malocclusion. Although minor enhancements in facial aesthetics were obtained, the occlusal function and dental aesthetics were significantly improved. Furthermore, the patient was very satisfied with his new smile appearance. Some advantages of this treatment option included the small invasiveness and the remarkably low financial costs involved. Moreover, the final results fulfilled all realistic treatment objectives and the patient's expectations. Results remained stable 5 years post-treatment demonstrating that excellent results can be obtained when simple and low cost, but well-controlled mechanics are conducted.
A Synthetic Quadrature Phase Detector/Demodulator for Fourier Transform Transform Spectrometers
NASA Technical Reports Server (NTRS)
Campbell, Joel
2008-01-01
A method is developed to demodulate (velocity correct) Fourier transform spectrometer (FTS) data that is taken with an analog to digital converter that digitizes equally spaced in time. This method makes it possible to use simple low cost, high resolution audio digitizers to record high quality data without the need for an event timer or quadrature laser hardware, and makes it possible to use a metrology laser of any wavelength. The reduced parts count and simplicity implementation makes it an attractive alternative in space based applications when compared to previous methods such as the Brault algorithm.
Bai, Wushuang; Sheng, Qinglin; Nie, Fei; Zheng, Jianbin
2015-12-30
Controllable synthesis of manganese oxides was performed via a simple one-step synthetic method. Then obtained manganese oxides which exhibit flower-like, cloud-like, hexagon-like, and rod-like morphologies were modified by formaldehyde based on a simple self-made gas-liquid reaction device respectively and the modified manganese oxides with coral-like, scallop-like and rod-like morphology were synthesized accordingly. The obtained materials were characterized and the formation mechanism was also researched. Then the modified manganese oxides were used to fabricate electrochemical sensors to detect H2O2. Comparison of electrochemical properties between three kinds of modified manganese oxides was investigated and the best one has been successfully employed as H2O2 sensor which shows a low detection limit of 0.01 μM, high sensitivity of 162.69 μA mM(-1) cm(-2), and wide linear range of 0.05 μM-12.78 mM. The study provides a new method for controllable synthesis of metal oxides, and electrochemical application of formaldehyde modified manganese oxides will provides a new strategy for electrochemical sensing with high performance, low cost, and simple fabrication.
Applications of cold hibernated elastic memory (CHEM) structures
NASA Technical Reports Server (NTRS)
Sokolowski, W. M.; Hayashi, S.
2003-01-01
Experiments and analyses have confirmed the feasibility of an innovative, new class of very simple, reliable, low mass, low packaging volume, and low-cost self-deployable structures for space and commercial applications.
Exclusion-Based Capture and Enumeration of CD4+ T Cells from Whole Blood for Low-Resource Settings.
Howard, Alexander L; Pezzi, Hannah M; Beebe, David J; Berry, Scott M
2014-06-01
In developing countries, demand exists for a cost-effective method to evaluate human immunodeficiency virus patients' CD4(+) T-helper cell count. The TH (CD4) cell count is the current marker used to identify when an HIV patient has progressed to acquired immunodeficiency syndrome, which results when the immune system can no longer prevent certain opportunistic infections. A system to perform TH count that obviates the use of costly flow cytometry will enable physicians to more closely follow patients' disease progression and response to therapy in areas where such advanced equipment is unavailable. Our system of two serially-operated immiscible phase exclusion-based cell isolations coupled with a rapid fluorescent readout enables exclusion-based isolation and accurate counting of T-helper cells at lower cost and from a smaller volume of blood than previous methods. TH cell isolation via immiscible filtration assisted by surface tension (IFAST) compares well against the established Dynal T4 Quant Kit and is sensitive at CD4 counts representative of immunocompromised patients (less than 200 TH cells per microliter of blood). Our technique retains use of open, simple-to-operate devices that enable IFAST as a high-throughput, automatable sample preparation method, improving throughput over previous low-resource methods. © 2013 Society for Laboratory Automation and Screening.
Carvalho, Rimenys J; Cruz, Thayana A
2018-01-01
High-throughput screening (HTS) systems have emerged as important tools to provide fast and low cost evaluation of several conditions at once since it requires small quantities of material and sample volumes. These characteristics are extremely valuable for experiments with large number of variables enabling the application of design of experiments (DoE) strategies or simple experimental planning approaches. Once, the capacity of HTS systems to mimic chromatographic purification steps was established, several studies were performed successfully including scale down purification. Here, we propose a method for studying different purification conditions that can be used for any recombinant protein, including complex and glycosylated proteins, using low binding filter microplates.
NASA Astrophysics Data System (ADS)
Wang, Andong; Jiang, Lan; Li, Xiaowei; Wang, Zhi; Du, Kun; Lu, Yongfeng
2018-05-01
Ultrafast laser pulse temporal shaping has been widely applied in various important applications such as laser materials processing, coherent control of chemical reactions, and ultrafast imaging. However, temporal pulse shaping has been limited to only-in-lab technique due to the high cost, low damage threshold, and polarization dependence. Herein we propose a novel design of ultrafast laser pulse train generation device, which consists of multiple polarization-independent parallel-aligned thin films. Various pulse trains with controllable temporal profile can be generated flexibly by multi-reflections within the splitting films. Compared with other pulse train generation techniques, this method has advantages of compact structure, low cost, high damage threshold and polarization independence. These advantages endow it with high potential for broad utilization in ultrafast applications.
Diego, Ariel de Lima; Stemberg Martins, de Vasconcelos,; Dias, Leite, José Alberto; Moreira, Pinto, Dilamar; Beltrão, Teixeira, Rogério; Coelho, de Léo, Álvaro; de Lima, Silveira, Leonardo; Krause, Gonçalves, Romeu; Carvalho Krause, Gonçalves, Marcelo; Carolina Leite, de Vasconcelos, Ana; Dias Costa, Filho, Carlos Frederico; Lana Lacerda, de Lima,
2017-01-01
Background: An anterior cruciate ligament (ACL) rupture is a frequent injury, with short and long-term consequences if left untreated. With a view to benefitting as many patients as possible and preventing future complications, we created a low-cost ligament reconstruction technique. Method: The present article describes an anatomic ACL reconstruction technique. Results: The technique involves single-band reconstruction, using flexors tendon graft, outside-in tunnel perforation, femoral fixation with metal interference screw and surgical staples (Agrafe) in the longitudinal position. Conclusion: We present a simple, easy-to-reproduce technique that, when executed on patients with good bone quality, primarily in the tibia, is effective and inexpensive, favoring its large scale application. PMID:29290851
NASA Technical Reports Server (NTRS)
Vangenderen, J. L. (Principal Investigator); Lock, B. F.
1976-01-01
The author has identified the following significant results. It was found that color composite transparencies and monocular magnification provided the best base for land use interpretation. New methods for determining optimum sample sizes and analyzing interpretation accuracy levels were developed. All stages of the methodology were assessed, in the operational sense, during the production of a 1:250,000 rural land use map of Murcia Province, Southeast Spain.
ShareSync: A Solution for Deterministic Data Sharing over Ethernet
NASA Technical Reports Server (NTRS)
Dunn, Daniel J., II; Koons, William A.; Kennedy, Richard D.; Davis, Philip A.
2007-01-01
As part of upgrading the Contact Dynamics Simulation Laboratory (CDSL) at the NASA Marshall Space Flight Center (MSFC), a simple, cost effective method was needed to communicate data among the networked simulation machines and I/O controllers used to run the facility. To fill this need and similar applicable situations, a generic protocol was developed, called ShareSync. ShareSync is a lightweight, real-time, publish-subscribe Ethernet protocol for simple and deterministic data sharing across diverse machines and operating systems. ShareSync provides a simple Application Programming Interface (API) for simulation programmers to incorporate into their code. The protocol is compatible with virtually all Ethernet-capable machines, is flexible enough to support a variety of applications, is fast enough to provide soft real-time determinism, and is a low-cost resource for distributed simulation development, deployment, and maintenance. The first design cycle iteration of ShareSync has been completed, and the protocol has undergone several testing procedures including endurance and benchmarking tests and approaches the 2001ts data synchronization design goal for the CDSL.
The acquisition of simple associations as observed in color-word contingency learning.
Lin, Olivia Y-H; MacLeod, Colin M
2018-01-01
Three experiments investigated the learning of simple associations in a color-word contingency task. Participants responded manually to the print colors of 3 words, with each word associated strongly to 1 of the 3 colors and weakly to the other 2 colors. Despite the words being irrelevant, response times to high-contingency stimuli and to low-contingency stimuli quickly diverged. This high-low difference remained quite constant over successive blocks of trials, evidence of stable contingency learning. Inclusion of a baseline condition-an item having no color-word contingency-permitted separation of the contingency learning effect into 2 components: a cost due to low contingency and a benefit due to high contingency. Both cost and benefit were quick to acquire, quick to extinguish, and quick to reacquire. The color-word contingency task provides a simple way to directly study the learning of associations. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Design and Field Test of a WSN Platform Prototype for Long-Term Environmental Monitoring
Lazarescu, Mihai T.
2015-01-01
Long-term wildfire monitoring using distributed in situ temperature sensors is an accurate, yet demanding environmental monitoring application, which requires long-life, low-maintenance, low-cost sensors and a simple, fast, error-proof deployment procedure. We present in this paper the most important design considerations and optimizations of all elements of a low-cost WSN platform prototype for long-term, low-maintenance pervasive wildfire monitoring, its preparation for a nearly three-month field test, the analysis of the causes of failure during the test and the lessons learned for platform improvement. The main components of the total cost of the platform (nodes, deployment and maintenance) are carefully analyzed and optimized for this application. The gateways are designed to operate with resources that are generally used for sensor nodes, while the requirements and cost of the sensor nodes are significantly lower. We define and test in simulation and in the field experiment a simple, but effective communication protocol for this application. It helps to lower the cost of the nodes and field deployment procedure, while extending the theoretical lifetime of the sensor nodes to over 16 years on a single 1 Ah lithium battery. PMID:25912349
2012-01-01
treatment applications using solar light as a renewable source of energy. Introduction The need for low cost and efficient water treatment strategies... photocatalysis with nanoparticles (such as titania, TiO2) show tremendous promise as a simple and energy efficient tech- nology for water purification and...which limits the amount of available sunlight that can be used for photocatalysis . To circumvent this issue, methods have been developed to extend
NASA Astrophysics Data System (ADS)
Stewart, R. D.; Abou Najm, M. R.; Rupp, D. E.; Selker, J. S.
2010-12-01
Shrinking/swelling soils are characterized by transient crack networks which function as dominant controls on the partitioning of surface and subsurface flow, the rate and depth of percolation, and evaporation rates. For such soils, understanding the dynamics of cracks is critical to accurately quantify their influence on groundwater recharge, stream-flow generation, and solute transport, among other component of a site’s hydrology. We propose a low-cost method for measuring transient crack-volume using a sealed plastic bag connected by a hose to a PVC standpipe. The empty bag is placed into the crack, and then water is added via the standpipe, until the bag has expanded to the boundaries of the crack and some water remains in the standpipe. As the crack shrinks or swells, its volume changes, causing water displacement within the bag, which is measured as a corresponding change in water level in the standpipe. An automated level logger within the standpipe is used to record changes in water level, which are converted to volumetric changes from the known internal cross-sectional area of the standpipe. The volume of water filling the bag is accurately measured at the start and completion of the experiment (to check for leakage). Adding the startup volume to the cumulative temporal volumetric change in the standpipe provides a simple and accurate method for monitoring transient crack volume. Currently, the design is undergoing preliminary testing in a field site in Ninhue, Chile, and field and laboratory testing in Corvallis, Oregon. Initial results from the Chilean field site suggest that the crack-o-meters are responding to the closing of cracks, but further effort is needed to calibrate and validate the results. We hope that these low-cost “crack-o-meters” will become useful and simple tools for researchers to quantify temporal changes in crack volume with the objective of incorporating these results into hydrological modeling efforts.
Skateboard/Longboard Speedometer Project
ERIC Educational Resources Information Center
Hare, Jonathan
2012-01-01
A simple, low-cost infrared LED speedometer is described that can be fitted to a skateboard, longboard or even a bicycle to measure speed. Notes on building, setting up and calibration are given. When used with a low-cost data logger, continuous measurements of speed can be made while out and about. The device forms an interesting science club…
Boyle, John J.; Kume, Maiko; Wyczalkowski, Matthew A.; Taber, Larry A.; Pless, Robert B.; Xia, Younan; Genin, Guy M.; Thomopoulos, Stavros
2014-01-01
When mechanical factors underlie growth, development, disease or healing, they often function through local regions of tissue where deformation is highly concentrated. Current optical techniques to estimate deformation can lack precision and accuracy in such regions due to challenges in distinguishing a region of concentrated deformation from an error in displacement tracking. Here, we present a simple and general technique for improving the accuracy and precision of strain estimation and an associated technique for distinguishing a concentrated deformation from a tracking error. The strain estimation technique improves accuracy relative to other state-of-the-art algorithms by directly estimating strain fields without first estimating displacements, resulting in a very simple method and low computational cost. The technique for identifying local elevation of strain enables for the first time the successful identification of the onset and consequences of local strain concentrating features such as cracks and tears in a highly strained tissue. We apply these new techniques to demonstrate a novel hypothesis in prenatal wound healing. More generally, the analytical methods we have developed provide a simple tool for quantifying the appearance and magnitude of localized deformation from a series of digital images across a broad range of disciplines. PMID:25165601
Webcam camera as a detector for a simple lab-on-chip time based approach.
Wongwilai, Wasin; Lapanantnoppakhun, Somchai; Grudpan, Supara; Grudpan, Kate
2010-05-15
A modification of a webcam camera for use as a small and low cost detector was demonstrated with a simple lab-on-chip reactor. Real time continuous monitoring of the reaction zone could be done. Acid-base neutralization with phenolphthalein indicator was used as a model reaction. The fading of pink color of the indicator when the acidic solution diffused into the basic solution zone was recorded as the change of red, blue and green colors (%RBG.) The change was related to acid concentration. A low cost portable semi-automation analysis system was achieved.
Technique for Very High Order Nonlinear Simulation and Validation
NASA Technical Reports Server (NTRS)
Dyson, Rodger W.
2001-01-01
Finding the sources of sound in large nonlinear fields via direct simulation currently requires excessive computational cost. This paper describes a simple technique for efficiently solving the multidimensional nonlinear Euler equations that significantly reduces this cost and demonstrates a useful approach for validating high order nonlinear methods. Up to 15th order accuracy in space and time methods were compared and it is shown that an algorithm with a fixed design accuracy approaches its maximal utility and then its usefulness exponentially decays unless higher accuracy is used. It is concluded that at least a 7th order method is required to efficiently propagate a harmonic wave using the nonlinear Euler equations to a distance of 5 wavelengths while maintaining an overall error tolerance that is low enough to capture both the mean flow and the acoustics.
Michalke, Bernhard
2017-03-01
Boron exposure is of interest and concern from an occupational point of view. Usual daily boron intake is related to boron blood plasma concentration <1mg/L and to <3mg/L in urine, but after exposure urine concentrations are quickly elevated. Reliable boron biomonitoring, typically in urine, thus is mandatory for occupational health control institutions. This paper reports on the development of a simple, fast and reliable boron determination procedure based on inductively coupled plasma - optical emission spectrometry (ICP-OES). Major aims for this method were simplicity in sample preparation, low risk for artifacts and interferences, high precision and accuracy, possibly low costs, including lower costs for element selective detection, short total analysis time and suitability for occupational health laboratories. Precision data (serial or day-to-day) from urine and doped urine were very good: <1.5 or <2%. Accuracy was calculated from analysis of a certified reference material (ERM-CD 281), as 99% or according to recoveries of doped concentrations ranging from 102 to 109% recovery. For cross-checking ICP-OES determinations, samples were analyzed also by quadrupole ICP-qMS and by sectorfield ICP-sf-MS at low and medium resolution. Both systems confirmed ICP-OES measurements when using 11 B for quantification. Determinations based on 10 B however showed some bias, except with ICP-sf-MS at medium resolution. The observed elevated signals are discussed with respect to the known Ne ++ interference (as an impurity in Ar), which is not separated in low resolving quadrupole ICP-MS systems or ICP-sf-MS at low resolution. Copyright © 2016 Elsevier GmbH. All rights reserved.
A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.
Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric
2012-03-07
We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.
Jeon, Hyungkook; Kim, Youngkyu; Lim, Geunbae
2016-01-28
In this paper, we introduce pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE), a novel continuous separation method. In our separation system, the external flow and electric field are applied to particles, such that particle movement is affected by pressure-driven flow, electroosmosis, and electrophoresis. We then analyzed the hydrodynamic drag force and electrophoretic force applied to the particles in opposite directions. Based on this analysis, micro- and nano-sized particles were separated according to their electrophoretic mobilities with high separation efficiency. Because the separation can be achieved in a simple T-shaped microchannel, without the use of internal electrodes, it offers the advantages of low-cost, simple device fabrication and bubble-free operation, compared with conventional μ-FFE methods. Therefore, we expect the proposed separation method to have a wide range of filtering/separation applications in biochemical analysis.
Kowalczyk, Wojciech; Rybicki, Zbigniew; Tomaszewski, Dariusz; Truszczyński, Andrzej; Guzek, Aneta
2011-01-01
Although broncho-alveolar lavage (BAL) culture and protected specimen brush (PSB) are regarded as the most effective methods in the diagnosis of VAP, a simple endotracheal aspiration (EA) is frequently performed during routine care, because of its simplicity and low cost. We compared the effectiveness of EA with BAL and PSB in VAP patients. Sixty-one adult VAP patients, ventilated for longer than 48 h, were cultured with all three methods. Positive cultures were obtained from 63.9% of patients, with Acinetobacter baumannii being the most common pathogen. There was a high positive correlation between simple aspirates and BAL (k 0.817, CI 0.664-0.840, p <0.001) and aspirates and PSB (k 0.667, CI 0.483-0.871, p <0.001). Because of the high sensitivity of bronchial aspirate culturing, compared to BAL and PSB, it can be used successfully in most cases.
Jeon, Hyungkook; Kim, Youngkyu; Lim, Geunbae
2016-01-01
In this paper, we introduce pressure-driven flow-induced miniaturizing free-flow electrophoresis (PDF-induced μ-FFE), a novel continuous separation method. In our separation system, the external flow and electric field are applied to particles, such that particle movement is affected by pressure-driven flow, electroosmosis, and electrophoresis. We then analyzed the hydrodynamic drag force and electrophoretic force applied to the particles in opposite directions. Based on this analysis, micro- and nano-sized particles were separated according to their electrophoretic mobilities with high separation efficiency. Because the separation can be achieved in a simple T-shaped microchannel, without the use of internal electrodes, it offers the advantages of low-cost, simple device fabrication and bubble-free operation, compared with conventional μ-FFE methods. Therefore, we expect the proposed separation method to have a wide range of filtering/separation applications in biochemical analysis. PMID:26819221
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chou Chau, Yuan-Fong, E-mail: chou.fong@ubd.edu.bn; Lim, Chee Ming; Yoong, Voo Nyuk
2015-12-28
We propose a simple structure of photonic crystal fibers (PCFs) with high birefringence and low confinement loss based on one rectangular centric ring of smaller circular air holes (CAHs) in the fiber core, and three rings of larger CAHs in the fiber cladding. This simple geometry (using all CAHs with two different air hole sizes) is capable of achieving a flexible control of the birefringence, B = 5.501 × 10{sup −3}, and ultra-low confinement loss, 7.30 × 10{sup −5 }dB/km, at an excitation wavelength of λ = 1550 nm. The birefringence value is ∼5.0 times greater than that obtained for conventional CAH PCF. This simple structure has the added advantagemore » from the view point of easy fabrication, robustness, and cost. A full-vector finite element method combined with anisotropic perfectly matched layers was used to analyze the various fiber structures. We have analyzed four cases of CAH PCFs, focusing on the core asymmetry design as opposed to the conventional approach of CAHs or elliptical air holes on the cladding and core. The robustness against manufacturing inaccuracies of the proposed structure has also been further investigated in this work.« less
Developing a protocol for creating microfluidic devices with a 3D printer, PDMS, and glass
NASA Astrophysics Data System (ADS)
Collette, Robyn; Novak, Eric; Shirk, Kathryn
2015-03-01
Microfluidics research requires the design and fabrication of devices that have the ability to manipulate small volumes of fluid, typically ranging from microliters to picoliters. These devices are used for a wide range of applications including the assembly of materials and testing of biological samples. Many methods have been previously developed to create microfluidic devices, including traditional nanolithography techniques. However, these traditional techniques are cost-prohibitive for many small-scale laboratories. This research explores a relatively low-cost technique using a 3D printed master, which is used as a template for the fabrication of polydimethylsiloxane (PDMS) microfluidic devices. The masters are designed using computer aided design (CAD) software and can be printed and modified relatively quickly. We have developed a protocol for creating simple microfluidic devices using a 3D printer and PDMS adhered to glass. This relatively simple and lower-cost technique can now be scaled to more complicated device designs and applications. Funding provided by the Undergraduate Research Grant Program at Shippensburg University and the Student/Faculty Research Engagement Grants from the College of Arts and Sciences at Shippensburg University.
A simple, low-cost, data logging pendulum built from a computer mouse
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gintautas, Vadas; Hubler, Alfred
Lessons and homework problems involving a pendulum are often a big part of introductory physics classes and laboratory courses from high school to undergraduate levels. Although laboratory equipment for pendulum experiments is commercially available, it is often expensive and may not be affordable for teachers on fixed budgets, particularly in developing countries. We present a low-cost, easy-to-build rotary sensor pendulum using the existing hardware in a ball-type computer mouse. We demonstrate how this apparatus may be used to measure both the frequency and coefficient of damping of a simple physical pendulum. This easily constructed laboratory equipment makes it possible formore » all students to have hands-on experience with one of the most important simple physical systems.« less
Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.
2014-01-01
Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149
Cook, Darren A N; Pilotte, Nils; Minetti, Corrado; Williams, Steven A; Reimer, Lisa J
2017-11-06
Background: Molecular xenomonitoring (MX), the testing of insect vectors for the presence of human pathogens, has the potential to provide a non-invasive and cost-effective method for monitoring the prevalence of disease within a community. Current MX methods require the capture and processing of large numbers of mosquitoes, particularly in areas of low endemicity, increasing the time, cost and labour required. Screening the excreta/feces (E/F) released from mosquitoes, rather than whole carcasses, improves the throughput by removing the need to discriminate vector species since non-vectors release ingested pathogens in E/F. It also enables larger numbers of mosquitoes to be processed per pool. However, this new screening approach requires a method of efficiently collecting E/F. Methods: We developed a cone with a superhydrophobic surface to allow for the efficient collection of E/F. Using mosquitoes exposed to either Plasmodium falciparum , Brugia malayi or Trypanosoma brucei brucei, we tested the performance of the superhydrophobic cone alongside two other collection methods. Results: All collection methods enabled the detection of DNA from the three parasites. Using the superhydrophobic cone to deposit E/F into a small tube provided the highest number of positive samples (16 out of 18) and facilitated detection of parasite DNA in E/F from individual mosquitoes. Further tests showed that following a simple washing step, the cone can be reused multiple times, further improving its cost-effectiveness. Conclusions: Incorporating the superhydrophobic cone into mosquito traps or holding containers could provide a simple and efficient method for collecting E/F. Where this is not possible, swabbing the container or using the washing method facilitates the detection of the three parasites used in this study.
Egypt`s first subsea completion: A Gulf of Suez case history
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Hawary, A.; Hoffman, J.G.
1996-06-01
A case history of the Gulf of Suez Petroleum Co.`s (Gupco) first subsea completion is provided. The first completion was for Well GS 373-2, a previously drilled and tested exploration well located in the south portion of the gulf of Suez. Subsea technology was used to economically justify development of this one-well marginal field, which was discovered in 1978. Traditional methods proved to be too costly for development, therefore application of a low-cost subsea tree was used to capture the resources. In the Gulf of Suez, many fields have been discovered but have not been developed because of low reserves.more » These marginal projects can have a profound impact on the revenue and shareholder value if an economic method is used to exploit these opportunities. Platform installation was not feasible because of reserve size, hence the well has remained abandoned until recently. This paper presents a summarized look at subsea completion technology. The cost comparison of traditional development methods will be made, given the local cost structure in Egypt. The application of this technology has some limitations and constraints that will be discussed in the paper. Furthermore, the actual field installation of Egypt`s first subsea tree will be summarized. Also included is a discussion on simple remote controls and offshore installation operations.« less
NASA Astrophysics Data System (ADS)
Anis Atikah, Nurul; Yeng Weng, Leong; Anuar, Adzly; Chien Fat, Chau; Sahari, Khairul Salleh Mohamed; Zainal Abidin, Izham
2017-10-01
Currently, the methods of actuating robotic-based prosthetic limbs are moving away from bulky actuators to more fluid materials such as artificial muscles. The main disadvantages of these artificial muscles are their high cost of manufacturing, low-force generation, cumbersome and complex controls. A recent discovery into using super coiled polymer (SCP) proved to have low manufacturing costs, high force generation, compact and simple controls. Nevertheless, the non-linear controls still exists due to the nature of heat-based actuation, which is hysteresis. This makes position control difficult. Using electrically conductive devices allows for very quick heating, but not quick cooling. This research tries to solve the problem by using peltier devices, which can effectively heat and cool the SCP, hence giving way to a more precise control. The peltier device does not actively introduce more energy to a volume of space, which the coiled heating does; instead, it acts as a heat pump. Experiments were conducted to test the feasibility of using peltier as an actuating method on different diameters of nylon fishing strings. Based on these experiments, the performance characteristics of the strings were plotted, which could be used to control the actuation of the string efficiently in the future.
Facile method for the synthesis of gold nanoparticles using an ion coater
NASA Astrophysics Data System (ADS)
Lee, Seung Han; Jung, Hyun Kyu; Kim, Tae Cheol; Kim, Chang Hee; Shin, Chang Hwan; Yoon, Tae-Sik; Hong, A.-Ra; Jang, Ho Seong; Kim, Dong Hun
2018-03-01
Herein we report a metal nanoparticle synthesis method based on a physical vapor deposition process instead of the conventional wet process of chemical reactions in liquids. A narrow size distribution of synthesized gold nanoparticles was obtained using an ion coater on glycerin at low vapor pressure. The nanoparticle size could be modulated by controlling the sputtering conditions especially the discharge current. Due to the formation of gold nanoparticles, a surface plasmon resonance peak appeared at ∼530 nm in the absorption spectrum. The surface plasmon resonance peak exhibited red-shift with increasing size of the gold nanoparticles. Our results provide a simple, environmental friendly method for the synthesis of metal nanoparticles by combine low-cost deposition apparatus and a liquid medium, which is free from toxic reagents.
Simplified Life-Cycle Cost Estimation
NASA Technical Reports Server (NTRS)
Remer, D. S.; Lorden, G.; Eisenberger, I.
1983-01-01
Simple method for life-cycle cost (LCC) estimation avoids pitfalls inherent in formulations requiring separate estimates of inflation and interest rates. Method depends for validity observation that interest and inflation rates closely track each other.
A Low-Cost Liquid-Chromatography System Using a Spectronic 20-Based Detector.
ERIC Educational Resources Information Center
Jezorek, John R.; And Others
1986-01-01
Describes the design and evaluation of a Spectronic 20-based detector as well as a simple system for postcolumn derivatization useful for metal-ion chromatographic detection. Both detection and derivatization can be performed in the ultra-violet (UV) mode using a low-cost UV-visible spectrophotometer and UV-region derivatization reagents. (JN)
Low-Cost Educational Materials: How To Make, How To Use, How To Adapt. Inventory, Volume I.
ERIC Educational Resources Information Center
United Nations Educational, Scientific, and Cultural Organization, Bangkok (Thailand). Regional Office for Education in Asia and Oceania.
Instructions with line drawings and/or patterns are provided for making 85 of the exemplar products perpared in APEID-sponsored workshops, which reviewed current efforts and materials, and explored new strategies and directions in the utilization of low cost, simple, indigenous materials to fill the regional need for audiovisual resources. The…
Isolation of Aramid Nanofibers for High Strength and Toughness Polymer Nanocomposites.
Lin, Jiajun; Bang, Sun Hwi; Malakooti, Mohammad H; Sodano, Henry A
2017-03-29
The development of nanoscale reinforcements that can be used to improve the mechanical properties of a polymer remains a challenge due to the long-standing difficulties with exfoliation and dispersion of existing materials. The dissimilar chemical nature of common nanofillers (e.g., carbon nanotubes, graphene) and polymeric matrix materials is the main reason for imperfect filler dispersion and, consequently, low mechanical performance of their composites relative to theoretical predictions. Here, aramid nanofibers that are intrinsically dispersible in many polymers are prepared from commercial aramid fibers (Kevlar) and isolated through a simple, scalable, and low-cost controlled dissolution method. Integration of the aramid nanofibers in an epoxy resin results in nanocomposites with simultaneously improved elastic modulus, strength, and fracture toughness. The improvement of these two mutually exclusive properties of nanocomposites is comparable to the enhancement of widely reported carbon nanotube reinforced nanocomposites but with a cost-effective and more feasible method to achieve uniform and stable dispersion. The results indicate the potential for aramid nanofibers as a new class of reinforcements for polymers.
NASA Technical Reports Server (NTRS)
Maskew, Brian
1987-01-01
The VSAERO low order panel method formulation is described for the calculation of subsonic aerodynamic characteristics of general configurations. The method is based on piecewise constant doublet and source singularities. Two forms of the internal Dirichlet boundary condition are discussed and the source distribution is determined by the external Neumann boundary condition. A number of basic test cases are examined. Calculations are compared with higher order solutions for a number of cases. It is demonstrated that for comparable density of control points where the boundary conditions are satisfied, the low order method gives comparable accuracy to the higher order solutions. It is also shown that problems associated with some earlier low order panel methods, e.g., leakage in internal flows and junctions and also poor trailing edge solutions, do not appear for the present method. Further, the application of the Kutta conditions is extremely simple; no extra equation or trailing edge velocity point is required. The method has very low computing costs and this has made it practical for application to nonlinear problems requiring iterative solutions for wake shape and surface boundary layer effects.
0.8 V nanogenerator for mechanical energy harvesting using bismuth titanate-PDMS nanocomposite
NASA Astrophysics Data System (ADS)
Abinnas, N.; Baskaran, P.; Harish, S.; Ganesh, R. Sankar; Navaneethan, M.; Nisha, K. D.; Ponnusamy, S.; Muthamizhchelvan, C.; Ikeda, H.; Hayakawa, Y.
2017-10-01
We present a novel, low-cost approach to fabricate piezoelectric nanogenerators using Bismuth titanate (BiT)/Polydimethylsiloxane (PDMS) nanocomposite. The nanogenerator has the advantage of the simple process of fabrication and is eco-friendly. This simple device was fabricated to harvest the energy released from finger tapping. This device generated an output of 0.8 V. The BiT samples were synthesized by wet chemical method. The structural, dielectric and ferroelectric properties of the samples were analyzed. Phase analysis using X-ray diffraction indicated that the phase structure was orthorhombic. The FESEM images of the sample calcined at 700 °C exhibited sheet-like morphology. Further characterizations like XPS, Raman studies, TEM were done.
Silva, Thalita G; de Araujo, William R; Muñoz, Rodrigo A A; Richter, Eduardo M; Santana, Mário H P; Coltro, Wendell K T; Paixão, Thiago R L C
2016-05-17
We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.
Pd(OAc)2/Ph3P-catalyzed dimerization of isoprene and synthesis of monoterpenic heterocycles.
Kellner, Dominik; Weger, Maximilian; Gini, Andrea; Mancheño, Olga García
2017-01-01
The palladium-catalyzed dimerization of isoprene is a practical approach of synthesizing monoterpenes. Though several highly selective methods have been reported, most of them still required pressure or costly ligands for attaining the active system and desired selectivity. Herein, we present a simple and economical procedure towards the tail-to-tail dimer using readily available Pd(OAc) 2 and inexpensive triphenylphosphine as ligand. Furthermore, simple screw cap vials are employed, allowing carrying out the reaction at low pressure. In addition, the potential of the dimer as a chemical platform for the preparation of heterocyclic terpenes by subsequent (hetero)-Diels-Alder or [4 + 1]-cycloadditions with nitrenes is also depicted.
Predicting dietary intakes with simple food recall information: a case study from rural Mozambique.
Rose, D; Tschirley, D
2003-10-01
Improving dietary status is an important development objective, but monitoring of progress in this area can be too costly for many low-income countries. This paper demonstrates a simple, inexpensive technique for monitoring household diets in Mozambique. Secondary analysis of data from an intensive field survey on household food consumption and agricultural practices, known as the Nampula/Cabo Delgado Study (NCD). In total, 388 households in 16 villages from a stratified random sample of rural areas in Nampula and Cabo Delgado provinces in northern Mozambique. The NCD employed a quantitative 24-h food recall on two nonconsecutive days in each of the three different seasons. A dietary intake prediction model was developed with linear regression techniques based on NCD nutrient intake data and easy-to-collect variables, such as food group consumption and household size The model was used to predict the prevalence of low intakes among subsamples from the field study using only easy-to-collect variables. Using empirical data for the harvest season from the original NCD study, 40% of the observations on households had low-energy intakes, whereas rates of low intake for protein, vitamin A, and iron, were 14, 94, and 39, respectively. The model developed here predicted that 42% would have low-energy intakes and that 12, 93, and 35% would have low-protein, vitamin A, and iron intakes, respectively. Similarly, close predictions were found using an aggregate index of overall diet quality. This work demonstrates the potential for using low-cost methods for monitoring dietary intake in Mozambique.
NASA Astrophysics Data System (ADS)
Hou, Ligang; Luo, Rengui; Wu, Wuchen
2006-11-01
This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.
Pointo - a Low Cost Solution to Point Cloud Processing
NASA Astrophysics Data System (ADS)
Houshiar, H.; Winkler, S.
2017-11-01
With advance in technology access to data especially 3D point cloud data becomes more and more an everyday task. 3D point clouds are usually captured with very expensive tools such as 3D laser scanners or very time consuming methods such as photogrammetry. Most of the available softwares for 3D point cloud processing are designed for experts and specialists in this field and are usually very large software packages containing variety of methods and tools. This results in softwares that are usually very expensive to acquire and also very difficult to use. Difficulty of use is caused by complicated user interfaces that is required to accommodate a large list of features. The aim of these complex softwares is to provide a powerful tool for a specific group of specialist. However they are not necessary required by the majority of the up coming average users of point clouds. In addition to complexity and high costs of these softwares they generally rely on expensive and modern hardware and only compatible with one specific operating system. Many point cloud customers are not point cloud processing experts or willing to spend the high acquisition costs of these expensive softwares and hardwares. In this paper we introduce a solution for low cost point cloud processing. Our approach is designed to accommodate the needs of the average point cloud user. To reduce the cost and complexity of software our approach focuses on one functionality at a time in contrast with most available softwares and tools that aim to solve as many problems as possible at the same time. Our simple and user oriented design improve the user experience and empower us to optimize our methods for creation of an efficient software. In this paper we introduce Pointo family as a series of connected softwares to provide easy to use tools with simple design for different point cloud processing requirements. PointoVIEWER and PointoCAD are introduced as the first components of the Pointo family to provide a fast and efficient visualization with the ability to add annotation and documentation to the point clouds.
High-fidelity, low-cost, automated method to assess laparoscopic skills objectively.
Gray, Richard J; Kahol, Kanav; Islam, Gazi; Smith, Marshall; Chapital, Alyssa; Ferrara, John
2012-01-01
We sought to define the extent to which a motion analysis-based assessment system constructed with simple equipment could measure technical skill objectively and quantitatively. An "off-the-shelf" digital video system was used to capture the hand and instrument movement of surgical trainees (beginner level = PGY-1, intermediate level = PGY-3, and advanced level = PGY-5/fellows) while they performed a peg transfer exercise. The video data were passed through a custom computer vision algorithm that analyzed incoming pixels to measure movement smoothness objectively. The beginner-level group had the poorest performance, whereas those in the advanced group generated the highest scores. Intermediate-level trainees scored significantly (p < 0.04) better than beginner trainees. Advanced-level trainees scored significantly better than intermediate-level trainees and beginner-level trainees (p < 0.04 and p < 0.03, respectively). A computer vision-based analysis of surgical movements provides an objective basis for technical expertise-level analysis with construct validity. The technology to capture the data is simple, low cost, and readily available, and it obviates the need for expert human assessment in this setting. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Measurement of jaw motion: the proposal of a simple and accurate method.
Pinheiro, A P; Pereira, A A; Andrade, A O; Bellomo, D
2011-01-01
The analysis of jaw movements has long been used as a measure for clinical diagnosis and assessment. A number of strategies are available for monitoring the trajectory; however most of these strategies make use of expensive tools, which are often not available to many clinics in the world. In this context, this research proposes the development of a new tool capable of quantifying the movements of opening/closing, protrusion and laterotrusion of the mandible. These movements are important for the clinical evaluation of both the temporomandibular function and muscles involved in mastication. The proposed system, unlike current commercial systems, employs a low-cost video camera and a computer program, which is used for reconstructing the trajectory of a reflective marker that is fixed on the jaw. In order to illustrate the application of the devised tool a clinical trial was carried out, investigating jaw movements of 10 subjects. The results obtained in this study were compatible with those found in the literature with the advantage of using a low-cost, simple, non-invasive and flexible solution customized for the practical needs of clinics. The average error of the system was less than 1.0%.
Towards microscale electrohydrodynamic three-dimensional printing
NASA Astrophysics Data System (ADS)
He, Jiankang; Xu, Fangyuan; Cao, Yi; Liu, Yaxiong; Li, Dichen
2016-02-01
It is challenging for the existing three-dimensional (3D) printing techniques to fabricate high-resolution 3D microstructures with low costs and high efficiency. In this work we present a solvent-based electrohydrodynamic 3D printing technique that allows fabrication of microscale structures like single walls, crossed walls, lattice and concentric circles. Process parameters were optimized to deposit tiny 3D patterns with a wall width smaller than 10 μm and a high aspect ratio of about 60. Tight bonding among neighbour layers could be achieved with a smooth lateral surface. In comparison with the existing microscale 3D printing techniques, the presented method is low-cost, highly efficient and applicable to multiple polymers. It is envisioned that this simple microscale 3D printing strategy might provide an alternative and innovative way for application in MEMS, biosensor and flexible electronics.
A novel 360-degree shape measurement using a simple setup with two mirrors and a laser MEMS scanner
NASA Astrophysics Data System (ADS)
Jin, Rui; Zhou, Xiang; Yang, Tao; Li, Dong; Wang, Chao
2017-09-01
There is no denying that 360-degree shape measurement technology plays an important role in the field of threedimensional optical metrology. Traditional optical 360-degree shape measurement methods are mainly two kinds: the first kind, by placing multiple scanners to achieve 360-degree measurements; the second kind, through the high-precision rotating device to get 360-degree shape model. The former increases the number of scanners and costly, while the latter using rotating devices lead to time consuming. This paper presents a low cost and fast optical 360-degree shape measurement method, which possesses the advantages of full static, fast and low cost. The measuring system consists of two mirrors with a certain angle, a laser projection system, a stereoscopic calibration block, and two cameras. And most of all, laser MEMS scanner can achieve precise movement of laser stripes without any movement mechanism, improving the measurement accuracy and efficiency. What's more, a novel stereo calibration technology presented in this paper can achieve point clouds data registration, and then get the 360-degree model of objects. A stereoscopic calibration block with special coded patterns on six sides is used in this novel stereo calibration method. Through this novel stereo calibration technology we can quickly get the 360-degree models of objects.
The construction and operation of a low-cost poultry waste digester.
Steinsberger, S C; Shih, J C
1984-05-01
A simple and low-cost poultry waste digester (PWD) was constructed to treat the waste from 4000 caged laying hens on University Research Unit No. 2 at North Carolina State University. The system was built basically of a plastic lining with insulation, a heating system, a hot-water tank, and other metering equipment. It was operated at 50 degrees C and pH 7.5-8.0. The initiation of methane production was achieved using the indigenous microflora in the poultry waste. At an optimal loading rate (7.5 kg volatile solids/m(3) day), the PWD produced biogas (55% methane) at a rate of 4.0 m(3)/m(3) day. The PWD was biologically stable and able to tolerate temporary overloads and shutdowns. A higher loading rate failed to maintain a high gas production rate and caused drops in methane content and pH value. Under optimal conditions, a positive energy balance was demonstrated with a net surplus of 50.6% of the gross energy. For methane production, the PWD system was proved to be technically feasible. The simple design and inexpensive materials used for this model could significantly reduce the cost of digestion compared to more conventional systems. More studies are needed to determine the durability, the required maintenance of the system, and the most economical method of biogas and solid residue utilization.
Kumar Dalapati, Goutam; Masudy-Panah, Saeid; Kumar, Avishek; Cheh Tan, Cheng; Ru Tan, Hui; Chi, Dongzhi
2015-12-03
This work demonstrates the fabrication of silicide/silicon based solar cell towards the development of low cost and environmental friendly photovoltaic technology. A heterostructure solar cells using metallic alpha phase (α-phase) aluminum alloyed iron silicide (FeSi(Al)) on n-type silicon is fabricated with an efficiency of 0.8%. The fabricated device has an open circuit voltage and fill-factor of 240 mV and 60%, respectively. Performance of the device was improved by about 7 fold to 5.1% through the interface engineering. The α-phase FeSi(Al)/silicon solar cell devices have promising photovoltaic characteristic with an open circuit voltage, short-circuit current and a fill factor (FF) of 425 mV, 18.5 mA/cm(2), and 64%, respectively. The significant improvement of α-phase FeSi(Al)/n-Si solar cells is due to the formation p(+-)n homojunction through the formation of re-grown crystalline silicon layer (~5-10 nm) at the silicide/silicon interface. Thickness of the regrown silicon layer is crucial for the silicide/silicon based photovoltaic devices. Performance of the α-FeSi(Al)/n-Si solar cells significantly depends on the thickness of α-FeSi(Al) layer and process temperature during the device fabrication. This study will open up new opportunities for the Si based photovoltaic technology using a simple, sustainable, and los cost method.
Low-Cost Propellant Launch to Earth Orbit from a Tethered Balloon
NASA Technical Reports Server (NTRS)
Wilcox, Brian H.
2006-01-01
Propellant will be more than 85% of the mass that needs to be lofted into Low Earth Orbit (LEO) in the planned program of Exploration of the Moon, Mars, and beyond. This paper describes a possible means for launching thousands of tons of propellant per year into LEO at a cost 15 to 30 times less than the current launch cost per kilogram. The basic idea is to mass-produce very simple, small and relatively low-performance rockets at a cost per kilogram comparable to automobiles, instead of the 25X greater cost that is customary for current launch vehicles that are produced in small quantities and which are manufactured with performance near the limits of what is possible. These small, simple rockets can reach orbit because they are launched above 95% of the atmosphere, where the drag losses even on a small rocket are acceptable, and because they can be launched nearly horizontally with very simple guidance based primarily on spin-stabilization. Launching above most of the atmosphere is accomplished by winching the rocket up a tether to a balloon. A fuel depot in equatorial orbit passes over the launch site on every orbit (approximately every 90 minutes). One or more rockets can be launched each time the fuel depot passes overhead, so the launch rate can be any multiple of 6000 small rockets per year, a number that is sufficient to reap the benefits of mass production.
Ultrahigh vacuum and low-temperature cleaning of oxide surfaces using a low-concentration ozone beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pratt, A.; Department of Physics, University of York, Heslington, York YO10 5DD; Graziosi, P.
We present a novel method of delivering a low-concentration (<15%) ozone beam to an ultra-high vacuum environment for the purpose of cleaning and dosing experimental samples through oxidation processing. The system described is safe, low-cost, and practical and overcomes the limitations of ozone transport in the molecular flow environment of high or ultrahigh vacuum whilst circumventing the use of pure ozone gas which is potentially highly explosive. The effectiveness of this method in removing surface contamination is demonstrated through comparison of high-temperature annealing of a simple oxide (MgO) in ozone and oxygen environments as monitored using quadrupole mass spectroscopy andmore » Auger electron spectroscopy. Additionally, we demonstrate the potential of ozone for obtaining clean complex oxide surfaces without the need for high-temperature annealing which may significantly alter surface structure.« less
Serra, M; Pereiro, I; Yamada, A; Viovy, J-L; Descroix, S; Ferraro, D
2017-02-14
The sealing of microfluidic devices remains a complex and time-consuming process requiring specific equipment and protocols: a universal method is thus highly desirable. We propose here the use of a commercially available sealing tape as a robust, versatile, reversible solution, compatible with cell and molecular biology protocols, and requiring only the application of manually achievable pressures. The performance of the seal was tested with regards to the most commonly used chip materials. For most materials, the bonding resisted 5 bars at room temperature and 1 bar at 95 °C. This method should find numerous uses, ranging from fast prototyping in the laboratory to implementation in low technology environments or industrial production.
Adapting smartphones for low-cost optical medical imaging
NASA Astrophysics Data System (ADS)
Pratavieira, Sebastião.; Vollet-Filho, José D.; Carbinatto, Fernanda M.; Blanco, Kate; Inada, Natalia M.; Bagnato, Vanderlei S.; Kurachi, Cristina
2015-06-01
Optical images have been used in several medical situations to improve diagnosis of lesions or to monitor treatments. However, most systems employ expensive scientific (CCD or CMOS) cameras and need computers to display and save the images, usually resulting in a high final cost for the system. Additionally, this sort of apparatus operation usually becomes more complex, requiring more and more specialized technical knowledge from the operator. Currently, the number of people using smartphone-like devices with built-in high quality cameras is increasing, which might allow using such devices as an efficient, lower cost, portable imaging system for medical applications. Thus, we aim to develop methods of adaptation of those devices to optical medical imaging techniques, such as fluorescence. Particularly, smartphones covers were adapted to connect a smartphone-like device to widefield fluorescence imaging systems. These systems were used to detect lesions in different tissues, such as cervix and mouth/throat mucosa, and to monitor ALA-induced protoporphyrin-IX formation for photodynamic treatment of Cervical Intraepithelial Neoplasia. This approach may contribute significantly to low-cost, portable and simple clinical optical imaging collection.
Museum genomics: low-cost and high-accuracy genetic data from historical specimens.
Rowe, Kevin C; Singhal, Sonal; Macmanes, Matthew D; Ayroles, Julien F; Morelli, Toni Lyn; Rubidge, Emily M; Bi, Ke; Moritz, Craig C
2011-11-01
Natural history collections are unparalleled repositories of geographical and temporal variation in faunal conditions. Molecular studies offer an opportunity to uncover much of this variation; however, genetic studies of historical museum specimens typically rely on extracting highly degraded and chemically modified DNA samples from skins, skulls or other dried samples. Despite this limitation, obtaining short fragments of DNA sequences using traditional PCR amplification of DNA has been the primary method for genetic study of historical specimens. Few laboratories have succeeded in obtaining genome-scale sequences from historical specimens and then only with considerable effort and cost. Here, we describe a low-cost approach using high-throughput next-generation sequencing to obtain reliable genome-scale sequence data from a traditionally preserved mammal skin and skull using a simple extraction protocol. We show that single-nucleotide polymorphisms (SNPs) from the genome sequences obtained independently from the skin and from the skull are highly repeatable compared to a reference genome. © 2011 Blackwell Publishing Ltd.
Kidwell, Mallory C.; Lazarević, Ljiljana B.; Baranski, Erica; Piechowski, Sarah; Falkenberg, Lina-Sophia; Sonnleitner, Carina; Fiedler, Susann; Nosek, Brian A.
2016-01-01
Beginning January 2014, Psychological Science gave authors the opportunity to signal open data and materials if they qualified for badges that accompanied published articles. Before badges, less than 3% of Psychological Science articles reported open data. After badges, 23% reported open data, with an accelerating trend; 39% reported open data in the first half of 2015, an increase of more than an order of magnitude from baseline. There was no change over time in the low rates of data sharing among comparison journals. Moreover, reporting openness does not guarantee openness. When badges were earned, reportedly available data were more likely to be actually available, correct, usable, and complete than when badges were not earned. Open materials also increased to a weaker degree, and there was more variability among comparison journals. Badges are simple, effective signals to promote open practices and improve preservation of data and materials by using independent repositories. PMID:27171007
Origami silicon optoelectronics for hemispherical electronic eye systems.
Zhang, Kan; Jung, Yei Hwan; Mikael, Solomon; Seo, Jung-Hun; Kim, Munho; Mi, Hongyi; Zhou, Han; Xia, Zhenyang; Zhou, Weidong; Gong, Shaoqin; Ma, Zhenqiang
2017-11-24
Digital image sensors in hemispherical geometries offer unique imaging advantages over their planar counterparts, such as wide field of view and low aberrations. Deforming miniature semiconductor-based sensors with high-spatial resolution into such format is challenging. Here we report a simple origami approach for fabricating single-crystalline silicon-based focal plane arrays and artificial compound eyes that have hemisphere-like structures. Convex isogonal polyhedral concepts allow certain combinations of polygons to fold into spherical formats. Using each polygon block as a sensor pixel, the silicon-based devices are shaped into maps of truncated icosahedron and fabricated on flexible sheets and further folded either into a concave or convex hemisphere. These two electronic eye prototypes represent simple and low-cost methods as well as flexible optimization parameters in terms of pixel density and design. Results demonstrated in this work combined with miniature size and simplicity of the design establish practical technology for integration with conventional electronic devices.
Bao, Rong-Rong; Zhang, Cheng-Yi; Zhang, Xiu-Juan; Ou, Xue-Mei; Lee, Chun-Sing; Jie, Jian-Sheng; Zhang, Xiao-Hong
2013-06-26
The controlled growth and alignment of one-dimensional organic nanostructures at well-defined locations considerably hinders the integration of nanostructures for electronic and optoelectronic applications. Here, we demonstrate a simple process to achieve the growth, alignment, and hierarchical patterning of organic nanowires on substrates with controlled patterns of surface wettability. The first-level pattern is confined by the substrate patterns of wettability. Organic nanostructures are preferentially grown on solvent wettable regions. The second-level pattern is the patterning of aligned organic nanowires deposited by controlling the shape and movement of the solution contact lines during evaporation on the wettable regions. This process is controlled by the cover-hat-controlled method or vertical evaportation method. Therefore, various new patterns of organic nanostructures can be obtained by combing these two levels of patterns. This simple method proves to be a general approach that can be applied to other organic nanostructure systems. Using the as-prepared patterned nanowire arrays, an optoelectronic device (photodetector) is easily fabricated. Hence, the proposed simple, large-scale, low-cost method of preparing patterns of highly ordered organic nanostructures has high potential applications in various electronic and optoelectronic devices.
ULTRA-SHARP solution of the Smith-Hutton problem
NASA Technical Reports Server (NTRS)
Leonard, B. P.; Mokhtari, Simin
1992-01-01
Highly convective scalar transport involving near-discontinuities and strong streamline curvature was addressed in a paper by Smith and Hutton in 1982, comparing several different convection schemes applied to a specially devised test problem. First order methods showed significant artificial diffusion, whereas higher order methods gave less smearing but had a tendency to overshoot and oscillate. Perhaps because unphysical oscillations are more obvious than unphysical smearing, the intervening period has seen a rise in popularity of low order artificially diffusive schemes, especially in the numerical heat transfer industry. The present paper describes an alternate strategy of using non-artificially diffusive high order methods, while maintaining strictly monotonic transitions through the use of simple flux limited constraints. Limited third order upwinding is usually found to be the most cost effective basic convection scheme. Tighter resolution of discontinuities can be obtained at little additional cost by using automatic adaptive stencil expansion to higher order in local regions, as needed.
Implementation of Preconditioned Dual-Time Procedures in OVERFLOW
NASA Technical Reports Server (NTRS)
Pandya, Shishir A.; Venkateswaran, Sankaran; Pulliam, Thomas H.; Kwak, Dochan (Technical Monitor)
2003-01-01
Preconditioning methods have become the method of choice for the solution of flowfields involving the simultaneous presence of low Mach and transonic regions. It is well known that these methods are important for insuring accurate numerical discretization as well as convergence efficiency over various operating conditions such as low Mach number, low Reynolds number and high Strouhal numbers. For unsteady problems, the preconditioning is introduced within a dual-time framework wherein the physical time-derivatives are used to march the unsteady equations and the preconditioned time-derivatives are used for purposes of numerical discretization and iterative solution. In this paper, we describe the implementation of the preconditioned dual-time methodology in the OVERFLOW code. To demonstrate the performance of the method, we employ both simple and practical unsteady flowfields, including vortex propagation in a low Mach number flow, flowfield of an impulsively started plate (Stokes' first problem) arid a cylindrical jet in a low Mach number crossflow with ground effect. All the results demonstrate that the preconditioning algorithm is responsible for improvements to both numerical accuracy and convergence efficiency and, thereby, enables low Mach number unsteady computations to be performed at a fraction of the cost of traditional time-marching methods.
Wu, Jing; Liu, Xianhu; Wang, Lili; Dong, Lijun; Pu, Qiaosheng
2012-01-21
An economical fluorescence detector was developed with an LED as the exciting source and a low-cost avalanche photodiode (APD) module as a photon sensor. The detector was arranged in an epifluorescence configuration using a microscope objective (20× or 40×) and a dichroic mirror. The low-cost APD was biased by a direct current (DC) high voltage power supply at 121 V, which is much lower than that normally used for a PMT. Both DC and square wave (SW) supplies were used to power the LED and different data treatment protocols, such as simple average for DC mode, software based lock-in amplification and time specific average for SW mode, were tested to maximize the signal-to-noise ratio. Using an LED at a DC mode with simple data averaging, a limit of detection of 0.2 nmol L(-1) for sodium fluorescein was attained, which is among the lowest ever achieved with an LED as an excitation source. The detector was successfully used in both capillary and chip electrophoresis. The most significant advantages of the detector are the compact size and low cost of its parts. The aim of the work is to prove that widely available, low-cost components for civilian use can be successfully used for miniaturized analytical devices.
ERIC Educational Resources Information Center
Young, Edmond W. K.; Simmons, Craig A.
2009-01-01
We describe a simple, low-cost laboratory session to demonstrate the Fahraeus-Lindqvist effect, a microphase flow phenomenon that occurs in small blood vessels and alters the effective rheological properties of blood. The experiments are performed by flowing cells through microchannels fabricated by soft lithography and characterization of cell…
ERIC Educational Resources Information Center
Wigton, Benjamin T.; Chohan, Balwant S.; McDonald, Cole; Johnson, Matt; Schunk, Doug; Kreuter, Rod; Sykes, Dan
2011-01-01
A low-cost portable fluorimeter was constructed using a 360 nm LED for excitation and a silicon photodiode for detection. The instrument is simple to operate and has been used to investigate fluorescent whitening agents extracted from various brands of paper, to determine the linear range and limit of detection of quinine in various commercial…
NASA Astrophysics Data System (ADS)
Gunawardena, N.; Pardyjak, E. R.; Stoll, R.; Khadka, A.
2018-02-01
Over the last decade there has been a proliferation of low-cost sensor networks that enable highly distributed sensor deployments in environmental applications. The technology is easily accessible and rapidly advancing due to the use of open-source microcontrollers. While this trend is extremely exciting, and the technology provides unprecedented spatial coverage, these sensors and associated microcontroller systems have not been well evaluated in the literature. Given the large number of new deployments and proposed research efforts using these technologies, it is necessary to quantify the overall instrument and microcontroller performance for specific applications. In this paper, an Arduino-based weather station system is presented in detail. These low-cost energy-budget measurement stations, or LEMS, have now been deployed for continuous measurements as part of several different field campaigns, which are described herein. The LEMS are low-cost, flexible, and simple to maintain. In addition to presenting the technical details of the LEMS, its errors are quantified in laboratory and field settings. A simple artificial neural network-based radiation-error correction scheme is also presented. Finally, challenges and possible improvements to microcontroller-based atmospheric sensing systems are discussed.
Optical biosensor based on liquid crystal droplets for detection of cholic acid
NASA Astrophysics Data System (ADS)
Niu, Xiaofang; Luo, Dan; Chen, Rui; Wang, Fei; Sun, Xiaowei; Dai, Haitao
2016-12-01
A highly sensitive cholic acid biosensor based on 4-cyano-4‧-penthlbiphenyl (5CB) Liquid crystal droplets in phosphate buffer saline solution was reported. A radial-to-bipolar transition of 5CB droplet would be triggered during competitive reaction of CA at the sodium dodecyl sulfate surfactant-laden 5CB droplet surface. Our liquid crystal droplet sensor is a low-cost, simple and fast method for CA detection. The detection limit (5 μM) of our method is 2.4 times lower than previously report by using liquid crystal film to detection of CA.
Ultra high vacuum broad band high power microwave window
Nguyen-Tuong, V.; Dylla, H.F. III
1997-11-04
An improved high vacuum microwave window has been developed that utilizes high density polyethylene coated on two sides with SiOx, SiNx, or a combination of the two. The resultant low dielectric and low loss tangent window creates a low outgassing, low permeation seal through which broad band, high power microwave energy may be passed. No matching device is necessary and the sealing technique is simple. The features of the window are broad band transmission, ultra-high vacuum compatibility with a simple sealing technique, low voltage standing wave ratio, high power transmission and low cost. 5 figs.
Ultra high vacuum broad band high power microwave window
Nguyen-Tuong, Viet; Dylla, III, Henry Frederick
1997-01-01
An improved high vacuum microwave window has been developed that utilizes high density polyethylene coated on two sides with SiOx, SiNx, or a combination of the two. The resultant low dielectric and low loss tangent window creates a low outgassing, low permeation seal through which broad band, high power microwave energy may be passed. No matching device is necessary and the sealing technique is simple. The features of the window are broad band transmission, ultra-high vacuum compatibility with a simple sealing technique, low voltage standing wave ratio, high power transmission and low cost.
Thin-film copper indium gallium selenide solar cell based on low-temperature all-printing process.
Singh, Manjeet; Jiu, Jinting; Sugahara, Tohru; Suganuma, Katsuaki
2014-09-24
In the solar cell field, development of simple, low-cost, and low-temperature fabrication processes has become an important trend for energy-saving and environmental issues. Copper indium gallium selenide (CIGS) solar cells have attracted much attention due to the high absorption coefficient, tunable band gap energy, and high efficiency. However, vacuum and high-temperature processing in fabrication of solar cells have limited the applications. There is a strong need to develop simple and scalable methods. In this work, a CIGS solar cell based on all printing steps and low-temperature annealing is developed. CIGS absorber thin film is deposited by using dodecylamine-stabilized CIGS nanoparticle ink followed by printing buffer layer. Silver nanowire (AgNW) ink and sol-gel-derived ZnO precursor solution are used to prepare a highly conductive window layer ZnO/[AgNW/ZnO] electrode with a printing method that achieves 16 Ω/sq sheet resistance and 94% transparency. A CIGS solar cell based on all printing processes exhibits efficiency of 1.6% with open circuit voltage of 0.48 V, short circuit current density of 9.7 mA/cm(2), and fill factor of 0.34 for 200 nm thick CIGS film, fabricated under ambient conditions and annealed at 250 °C.
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, Erh-Chia; Fu, Chi-Cheng; Hu, Lucy; Thakur, Rohan; Feng, Jeffrey; Lee, Luke P.
2017-01-01
Portable, low-cost, and quantitative nucleic acid detection is desirable for point-of-care diagnostics; however, current polymerase chain reaction testing often requires time-consuming multiple steps and costly equipment. We report an integrated microfluidic diagnostic device capable of on-site quantitative nucleic acid detection directly from the blood without separate sample preparation steps. First, we prepatterned the amplification initiator [magnesium acetate (MgOAc)] on the chip to enable digital nucleic acid amplification. Second, a simplified sample preparation step is demonstrated, where the plasma is separated autonomously into 224 microwells (100 nl per well) without any hemolysis. Furthermore, self-powered microfluidic pumping without any external pumps, controllers, or power sources is accomplished by an integrated vacuum battery on the chip. This simple chip allows rapid quantitative digital nucleic acid detection directly from human blood samples (10 to 105 copies of methicillin-resistant Staphylococcus aureus DNA per microliter, ~30 min, via isothermal recombinase polymerase amplification). These autonomous, portable, lab-on-chip technologies provide promising foundations for future low-cost molecular diagnostic assays. PMID:28345028
NASA Astrophysics Data System (ADS)
Con, Celal; Cui, Bo
2017-12-01
This paper describes a simple and low-cost fabrication method for multi-functional nanostructures with outstanding anti-reflective and super-hydrophobic properties. Our method employed phase separation of a metal salt-polymer nanocomposite film that leads to nanoisland formation after etching away the polymer matrix, and the metal salt island can then be utilized as a hard mask for dry etching the substrate or sublayer. Compared to many other methods for patterning metallic hard mask structures, such as the popular lift-off method, our approach involves only spin coating and thermal annealing, thus is more cost-efficient. Metal salts including aluminum nitrate nonahydrate (ANN) and chromium nitrate nonahydrate (CNN) can both be used, and high aspect ratio (1:30) and high-resolution (sub-50 nm) pillars etched into silicon can be achieved readily. With further control of the etching profile by adjusting the dry etching parameters, cone-like silicon structure with reflectivity in the visible region down to a remarkably low value of 2% was achieved. Lastly, by coating a hydrophobic surfactant layer, the pillar array demonstrated a super-hydrophobic property with an exceptionally high water contact angle of up to 165.7°.
Con, Celal; Cui, Bo
2017-12-16
This paper describes a simple and low-cost fabrication method for multi-functional nanostructures with outstanding anti-reflective and super-hydrophobic properties. Our method employed phase separation of a metal salt-polymer nanocomposite film that leads to nanoisland formation after etching away the polymer matrix, and the metal salt island can then be utilized as a hard mask for dry etching the substrate or sublayer. Compared to many other methods for patterning metallic hard mask structures, such as the popular lift-off method, our approach involves only spin coating and thermal annealing, thus is more cost-efficient. Metal salts including aluminum nitrate nonahydrate (ANN) and chromium nitrate nonahydrate (CNN) can both be used, and high aspect ratio (1:30) and high-resolution (sub-50 nm) pillars etched into silicon can be achieved readily. With further control of the etching profile by adjusting the dry etching parameters, cone-like silicon structure with reflectivity in the visible region down to a remarkably low value of 2% was achieved. Lastly, by coating a hydrophobic surfactant layer, the pillar array demonstrated a super-hydrophobic property with an exceptionally high water contact angle of up to 165.7°.
Visceral fat estimation method by bioelectrical impedance analysis and causal analysis
NASA Astrophysics Data System (ADS)
Nakajima, Hiroshi; Tasaki, Hiroshi; Tsuchiya, Naoki; Hamaguchi, Takehiro; Shiga, Toshikazu
2011-06-01
It has been clarified that abdominal visceral fat accumulation is closely associated to the lifestyle disease and metabolic syndrome. The gold standard in medical fields is visceral fat area measured by an X-ray computer tomography (CT) scan or magnetic resonance imaging. However, their measurements are high invasive and high cost; especially a CT scan causes X-ray exposure. They are the reasons why medical fields need an instrument for viscera fat measurement with low invasive, ease of use, and low cost. The article proposes a simple and practical method of visceral fat estimation by employing bioelectrical impedance analysis and causal analysis. In the method, abdominal shape and dual impedances of abdominal surface and body total are measured to estimate a visceral fat area based on the cause-effect structure. The structure is designed according to the nature of abdominal body composition to be fine-tuned by statistical analysis. The experiments were conducted to investigate the proposed model. 180 subjects were hired to be measured by both a CT scan and the proposed method. The acquired model explained the measurement principle well and the correlation coefficient is 0.88 with the CT scan measurements.
Yang, Zhong-Duo; Song, Zhu-Wen; Ren, Jin; Yang, Ming-Jun; Li, Shuo
2011-01-01
Thin-layer chromatography (TLC) bioautographic method is a simple and rapid method to screen acetylcholinesterase inhibitors from plant extracts. However, the high consumption of enzyme (6 U/mL) in current methods makes the procedure expensive, which is an obstacle to scientific research centers lacking funding. To develop a new low-cost TLC bioautographic method. A series of compounds, as substrates, were synthesised and their ability to be hydrolysed by acetylcholinesterase was evaluated by the HPLC method. 4-Methoxyphenyl acetate (14) was proved to be an appropriate substrate for TLC bioautographic assay. Therefore a new and cheap TLC bioautographic assay was set up. The mechanism of this new method is that the enzyme converts 4-methoxylphenyl acetate into 4-methoxyphenol, which reacts with a solution of potassium ferricyanide ([K₃(FeCN)₆]) and iron chloride hexahydrate (FeCl₃·6H₂O) to make an aquamarine blue coloured background on the TLC plates. Regions of the TLC plate which contain acetylcholinesterase inhibitors show up as light yellow spots against the background. The consumption of enzyme (1 U/mL) in the new method is low and the detection limit of two known acetylcholinesterase inhibitors, huperzine A (0.0001 μg) and physostigmine (0.001 μg), for this assay are close to published values. A low-cost TLC bioautographic method was developed, which will benefit research groups pursuing natural acetylcholinesterase inhibitors. Copyright © 2011 John Wiley & Sons, Ltd.
The Instructional Cost Index. A Simplified Approach to Interinstitutional Cost Comparison.
ERIC Educational Resources Information Center
Beatty, George, Jr.; And Others
The paper describes a simple, yet effective method of computing a comparative index of instructional costs. The Instructional Cost Index identifies direct cost differentials among instructional programs. Cost differentials are described in terms of differences among numerical values of variables that reflect fundamental academic and resource…
Photometric method for determination of acidity constants through integral spectra analysis
NASA Astrophysics Data System (ADS)
Zevatskiy, Yuriy Eduardovich; Ruzanov, Daniil Olegovich; Samoylov, Denis Vladimirovich
2015-04-01
An express method for determination of acidity constants of organic acids, based on the analysis of the integral transmittance vs. pH dependence is developed. The integral value is registered as a photocurrent of photometric device simultaneously with potentiometric titration. The proposed method allows to obtain pKa using only simple and low-cost instrumentation. The optical part of the experimental setup has been optimized through the exclusion of the monochromator device. Thus it only takes 10-15 min to obtain one pKa value with the absolute error of less than 0.15 pH units. Application limitations and reliability of the method have been tested for a series of organic acids of various nature.
NASA Astrophysics Data System (ADS)
Cha, Kyoung Je; Kim, Taewan; Jea Park, Sung; Kim, Dong Sung
2014-11-01
Polymer microneedle arrays (MNAs) have received much attention for their use in transdermal drug delivery and microneedle therapy systems due to the advantages they offer, such as low cost, good mechanical properties, and a versatile choice of materials. Here, we present a simple and cost-effective method for the fabrication of a biodegradable polymer MNA in which the aspect ratio of each microneedle is adjustable using commercially available acupuncture microneedles. In our process, a master template with acupuncture microneedles, whose shape will be the final MNA, was carefully prepared by fixing them onto a plastic substrate with selectively drilled holes which, in turn, determine the aspect ratios of the microneedles. A polylactic acid (PLA; a biodegradable polymer) MNA was fabricated by a micromolding process with a polydimethylsiloxane (PDMS) mold containing the cavity of the microneedles, which was obtained by the PDMS replica molding against the master template. The mechanical force and degradation behavior of the replicated PLA MNA were characterized with the help of a compression test and an accelerated degradation test, respectively. Finally, the transdermal drug delivery performance of the PLA MNA was successfully simulated by two different methods of penetration and staining, using the skin of a pig cadaver. These results indicated that the proposed method can be effectively used for the fabrication of polymer MNAs which can be used in various microneedle applications.
Adsorptive Removal of Toxic Chromium from Waste-Water Using Wheat Straw and Eupatorium adenophorum
Song, Dagang; Pan, Kaiwen; Tariq, Akash; Azizullah, Azizullah; Sun, Feng; Li, Zilong; Xiong, Qinli
2016-01-01
Environmental pollution with heavy metals is a serious issue worldwide posing threats to humans, animals and plants and to the stability of overall ecosystem. Chromium (Cr) is one of most hazardous heavy metals with a high carcinogenic and recalcitrant nature. Aim of the present study was to select low-cost biosorbent using wheat straw and Eupatorium adenophorum through simple carbonization process, capable of removing Cr (VI) efficiently from wastewater. From studied plants a low cost adsorbent was prepared for removing Cr (VI) from aqueous solution following very simple carbonization method excluding activation process. Several factors such as pH, contact time, sorbent dosage and temperature were investigated for attaining ideal condition. For analysis of adsorption equilibrium isotherm data, Langmuir, Freundlich and Temkin models were used while pseudo-first-order, pseudo-second-order, external diffusion and intra-particle diffusion models were used for the analysis of kinetic data. The obtained results revealed that 99.9% of Cr (VI) removal was observed in the solution with a pH of 1.0. Among all the tested models Langmuir model fitted more closely according to the data obtained. Increase in adsorption capacity was observed with increasing temperature revealing endothermic nature of Cr (VI). The maximum Cr (VI) adsorption potential of E. adenophorum and wheat straw was 89.22 mg per 1 gram adsorbent at 308K. Kinetic data of absorption precisely followed pseudo-second-order model. Present study revealed highest potential of E. adenophorum and wheat straw for producing low cost adsorbent and to remove Cr (VI) from contaminated water. PMID:27911906
Adsorptive Removal of Toxic Chromium from Waste-Water Using Wheat Straw and Eupatorium adenophorum.
Song, Dagang; Pan, Kaiwen; Tariq, Akash; Azizullah, Azizullah; Sun, Feng; Li, Zilong; Xiong, Qinli
2016-01-01
Environmental pollution with heavy metals is a serious issue worldwide posing threats to humans, animals and plants and to the stability of overall ecosystem. Chromium (Cr) is one of most hazardous heavy metals with a high carcinogenic and recalcitrant nature. Aim of the present study was to select low-cost biosorbent using wheat straw and Eupatorium adenophorum through simple carbonization process, capable of removing Cr (VI) efficiently from wastewater. From studied plants a low cost adsorbent was prepared for removing Cr (VI) from aqueous solution following very simple carbonization method excluding activation process. Several factors such as pH, contact time, sorbent dosage and temperature were investigated for attaining ideal condition. For analysis of adsorption equilibrium isotherm data, Langmuir, Freundlich and Temkin models were used while pseudo-first-order, pseudo-second-order, external diffusion and intra-particle diffusion models were used for the analysis of kinetic data. The obtained results revealed that 99.9% of Cr (VI) removal was observed in the solution with a pH of 1.0. Among all the tested models Langmuir model fitted more closely according to the data obtained. Increase in adsorption capacity was observed with increasing temperature revealing endothermic nature of Cr (VI). The maximum Cr (VI) adsorption potential of E. adenophorum and wheat straw was 89.22 mg per 1 gram adsorbent at 308K. Kinetic data of absorption precisely followed pseudo-second-order model. Present study revealed highest potential of E. adenophorum and wheat straw for producing low cost adsorbent and to remove Cr (VI) from contaminated water.
Coins and Costs: A Simple and Rapid Assessment of Basic Financial Knowledge
ERIC Educational Resources Information Center
Willner, Paul; Bailey, Rebecca; Dymond, Simon; Parry, Rhonwen
2011-01-01
Introduction: We describe a simple and rapid screening test for basic financial knowledge that is suitable for administration to people with mild intellectual disabilities. Method: The Coins and Costs test asks respondents to name coins, and to estimate prices of objects ranging between 1 British Pound (an ice cream) and 100K British Pounds (a…
Hierarchically ordered carbon tubes
NASA Astrophysics Data System (ADS)
Pan, Zheng-Wei; Zhu, Hao-Guo; Zhang, Zong-Tao; Im, Hee-Jung; Dai, Sheng; Beach, David B.; Lowndes, Douglas H.
2003-04-01
Micropatterns of hierarchically ordered carbon tubes (i.e., ordered carbon microtubes composed of aligned carbon nanotubes) were grown on a film-like iron/silica substrate consisting of ring-like catalyst patterns. The substrates were prepared by a combined technique, in which the sol-gel method was used to prepare catalyst film and transmission electron microscope grids were used as a shadow mask. In comparison with other techniques that involve sophisticated lithography, this approach represents a simple and low-cost way to the micropatterning of aligned carbon nanotubes.
How sweet the sound: research evidence for the use of music in Alzheimer's dementia.
Witzke, Jan; Rhone, Rebecca A; Backhaus, Diane; Shaver, Nanette A
2008-10-01
The purpose of this article is to provide an evidence-based synthesis of the research literature on music intervention for agitated behavior in Alzheimer's dementia. A qualitative review of the literature supported music as a low-cost, simple alternative to traditional methods of management, with minimal risk to the client. A rating system assigning levels of evidence to support these interventions was used, and implications for nursing practice innovations and further research are discussed.
Self-assembled pentacenequinone derivative for trace detection of picric acid.
Bhalla, Vandana; Gupta, Ankush; Kumar, Manoj; Rao, D S Shankar; Prasad, S Krishna
2013-02-01
Pentacenequinone derivative 3 forms luminescent supramolecular aggregates both in bulk as well as in solution phase. In bulk phase at high temperature, long-range stacking of columns leads to formation of stable and ordered columnar mesophase. Further, derivative 3 works as sensitive chemosensor for picric acid (PA) and gel-coated paper strips detect PA at nanomolar level and provide a simple, portable, and low-cost method for detection of PA in aqueous solution, vapor phase, and in contact mode.
Harrison, Thomas C; Sigler, Albrecht; Murphy, Timothy H
2009-09-15
We describe a simple and low-cost system for intrinsic optical signal (IOS) imaging using stable LED light sources, basic microscopes, and commonly available CCD cameras. IOS imaging measures activity-dependent changes in the light reflectance of brain tissue, and can be performed with a minimum of specialized equipment. Our system uses LED ring lights that can be mounted on standard microscope objectives or video lenses to provide a homogeneous and stable light source, with less than 0.003% fluctuation across images averaged from 40 trials. We describe the equipment and surgical techniques necessary for both acute and chronic mouse preparations, and provide software that can create maps of sensory representations from images captured by inexpensive 8-bit cameras or by 12-bit cameras. The IOS imaging system can be adapted to commercial upright microscopes or custom macroscopes, eliminating the need for dedicated equipment or complex optical paths. This method can be combined with parallel high resolution imaging techniques such as two-photon microscopy.
Culturing In Vivo-like Murine Astrocytes Using the Fast, Simple, and Inexpensive AWESAM Protocol.
Wolfes, Anne C; Dean, Camin
2018-01-10
The AWESAM (a low-cost easy stellate astrocyte method) protocol entails a fast, simple, and inexpensive way to generate large quantities of in vivo-like mouse and rat astrocyte monocultures: Brain cells can be isolated from different brain regions, and after a week of cell culture, non-astrocytic cells are shaken off by placing the culture dishes on a shaker for 6 h in the incubator. The remaining astrocytes are then passaged into new plates with an astrocyte-specific medium (termed NB+H). NB+H contains low concentrations of heparin-binding EGF-like growth factor (HBEGF), which is used in place of serum in medium. After growing in NB+H, AWESAM astrocytes have a stellate morphology and feature fine processes. Moreover, these astrocytes have more in vivo-like gene expression than astrocytes generated by previously published methods. Ca 2+ imaging, vesicle dynamics, and other events close to the membrane can thus be studied in the fine astrocytic processes in vitro, e.g., using live cell confocal or TIRF microscopy. Notably, AWESAM astrocytes also exhibit spontaneous Ca 2+ signaling similar to astrocytes in vivo.
Improving the large scale purification of the HIV microbicide, griffithsin.
Fuqua, Joshua L; Wanga, Valentine; Palmer, Kenneth E
2015-02-22
Griffithsin is a broad spectrum antiviral lectin that inhibits viral entry and maturation processes through binding clusters of oligomannose glycans on viral envelope glycoproteins. An efficient, scaleable manufacturing process for griffithsin active pharmaceutical ingredient (API) is essential for particularly cost-sensitive products such as griffithsin -based topical microbicides for HIV-1 prevention in resource poor settings. Our previously published purification method used ceramic filtration followed by two chromatography steps, resulting in a protein recovery of 30%. Our objective was to develop a scalable purification method for griffithsin expressed in Nicotiana benthamiana plants that would increase yield, reduce production costs, and simplify manufacturing techniques. Considering the future need to transfer griffithsin manufacturing technology to resource poor areas, we chose to focus modifying the purification process, paying particular attention to introducing simple, low-cost, and scalable procedures such as use of temperature, pH, ion concentration, and filtration to enhance product recovery. We achieved >99% pure griffithsin API by generating the initial green juice extract in pH 4 buffer, heating the extract to 55°C, incubating overnight with a bentonite MgCl2 mixture, and final purification with Capto™ multimodal chromatography. Griffithsin extracted with this protocol maintains activity comparable to griffithsin purified by the previously published method and we are able to recover a substantially higher yield: 88 ± 5% of griffithsin from the initial extract. The method was scaled to produce gram quantities of griffithsin with high yields, low endotoxin levels, and low purification costs maintained. The methodology developed to purify griffithsin introduces and develops multiple tools for purification of recombinant proteins from plants at an industrial scale. These tools allow for robust cost-effective production and purification of griffithsin. The methodology can be readily scaled to the bench top or industry and process components can be used for purification of additional proteins based on biophysical characteristics.
Sicras-Mainar, Antoni; Velasco-Velasco, Soledad; Navarro-Artieda, Ruth; Blanca Tamayo, Milagrosa; Aguado Jodar, Alba; Ruíz Torrejón, Amador; Prados-Torres, Alexandra; Violan-Fors, Concepción
2012-06-01
To compare three methods of measuring multiple morbidity according to the use of health resources (cost of care) in primary healthcare (PHC). Retrospective study using computerized medical records. Thirteen PHC teams in Catalonia (Spain). Assigned patients requiring care in 2008. The socio-demographic variables were co-morbidity and costs. Methods of comparison were: a) Combined Comorbidity Index (CCI): an index itself was developed from the scores of acute and chronic episodes, b) Charlson Index (ChI), and c) Adjusted Clinical Groups case-mix: resource use bands (RUB). The cost model was constructed by differentiating between fixed (operational) and variable costs. 3 multiple lineal regression models were developed to assess the explanatory power of each measurement of co-morbidity which were compared from the determination coefficient (R(2)), p< .05. The study included 227,235 patients. The mean unit of cost was €654.2. The CCI explained an R(2)=50.4%, the ChI an R(2)=29.2% and BUR an R(2)=39.7% of the variability of the cost. The behaviour of the ICC is acceptable, albeit with low scores (1 to 3 points), showing inconclusive results. The CCI may be a simple method of predicting PHC costs in routine clinical practice. If confirmed, these results will allow improvements in the comparison of the case-mix. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Back to the kitchen: food-grade agar is a low-cost alternative to bacteriological agar.
Petrovski, Steve; Tillett, Daniel
2012-10-15
Food-grade agar can be used as a low-cost substitute for bacteriological agar in the preparation of solid microbial media. No difference was observed in the colony morphology, growth rate, or viability of bacteria grown on solid media prepared using food-grade agar as compared with using bacteriological-grade agar. This simple tip can reduce the cost of the most common solid media by 80% or more. Copyright © 2012 Elsevier Inc. All rights reserved.
Swept Impact Seismic Technique (SIST)
Park, C.B.; Miller, R.D.; Steeples, D.W.; Black, R.A.
1996-01-01
A coded seismic technique is developed that can result in a higher signal-to-noise ratio than a conventional single-pulse method does. The technique is cost-effective and time-efficient and therefore well suited for shallow-reflection surveys where high resolution and cost-effectiveness are critical. A low-power impact source transmits a few to several hundred high-frequency broad-band seismic pulses during several seconds of recording time according to a deterministic coding scheme. The coding scheme consists of a time-encoded impact sequence in which the rate of impact (cycles/s) changes linearly with time providing a broad range of impact rates. Impact times used during the decoding process are recorded on one channel of the seismograph. The coding concept combines the vibroseis swept-frequency and the Mini-Sosie random impact concepts. The swept-frequency concept greatly improves the suppression of correlation noise with much fewer impacts than normally used in the Mini-Sosie technique. The impact concept makes the technique simple and efficient in generating high-resolution seismic data especially in the presence of noise. The transfer function of the impact sequence simulates a low-cut filter with the cutoff frequency the same as the lowest impact rate. This property can be used to attenuate low-frequency ground-roll noise without using an analog low-cut filter or a spatial source (or receiver) array as is necessary with a conventional single-pulse method. Because of the discontinuous coding scheme, the decoding process is accomplished by a "shift-and-stacking" method that is much simpler and quicker than cross-correlation. The simplicity of the coding allows the mechanical design of the source to remain simple. Several different types of mechanical systems could be adapted to generate a linear impact sweep. In addition, the simplicity of the coding also allows the technique to be used with conventional acquisition systems, with only minor modifications.
Force Eruption of Mandibular Second Incisor in an 11- Year Old Boy: A Technical Report
Sobhnamayan, F; Moazami, F; Hamedi, S; Meshki, R
2013-01-01
There is a great challenge in the treatment of deeply fractured and un-restorable teeth among dentists. Orthodontic force eruption is a method of treatment for these teeth to preserve natural root system and periodontal structures. This technical report is a new modification of this procedure presented in an 11- year old boy with deeply fractured left second mandibular incisor. The fractured teeth were treated with root canal therapy and a file #80 was modified to become a hook cemented into the fractured tooth. Anterior teeth were splinted and used as anchorage to help the root extrusion. 1-year follow up of the tooth showed the convenience of the treatment. This simple and low-cost method can be an acceptable alternative to the current high cost techniques, achieving the same results. PMID:24724126
Simple Demonstration of the Seebeck Effect
ERIC Educational Resources Information Center
Molki, Arman
2010-01-01
In this article we propose a simple and low-cost experimental set-up through which science educators can demonstrate the Seebeck effect using a thermocouple and an instrumentation amplifier. The experiment can be set up and conducted during a 1-hour laboratory session. (Contains 3 tables and 3 figures.)
Time-of-Flight Measurement of the Speed of Sound in Water
ERIC Educational Resources Information Center
Ganci, Salvatore
2016-01-01
A simple setup is designed to investigate a "time-of-flight" measurement of the speed of sound in water. This experiment only requires low cost components and is also very simple to understand by students. It could be easily used as a demonstration experiment.
MODIFICATIONS TO REDUCE DRAG OUT AT A PRINTED CIRCUIT BOARD MANUFACTURER
This MnTAP/EPA Waste Reduction Innovative Technology Evaluation project at Micom, Inc., demonstrated the waste reducing capability of two simple rinsing modifications on an etchant and an electroless copper process. he simple, tow (or no) cost, low technology changes that were ma...
Passive solar design strategies: Remodeling guidelines for conserving energy at home
NASA Astrophysics Data System (ADS)
The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy - but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical, and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive Solar Design Strategies: Remodeling Guidelines For Conserving Energy At Home is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: the guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; the worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; and the worked example demonstrates how to complete the worksheets for a typical residence.
Low Temperature Thermometry Using Inexpensive Silicon Diodes.
ERIC Educational Resources Information Center
Waltham, N. R.; And Others
1981-01-01
Describes the use of silicon diodes for low temperature thermometry in the teaching laboratory. A simple and inexpensive circuit for display of the diode forward voltage under constant current conditions is described, and its application in the evaluation of low cost silicon diodes as low temperature thermometers is presented. (SK)
NASA Astrophysics Data System (ADS)
Dabiri, M.; Ghafouri, M.; Rohani Raftar, H. R.; Björk, T.
2018-03-01
Methods to estimate the strain-life curve, which were divided into three categories: simple approximations, artificial neural network-based approaches and continuum damage mechanics models, were examined, and their accuracy was assessed in strain-life evaluation of a direct-quenched high-strength steel. All the prediction methods claim to be able to perform low-cycle fatigue analysis using available or easily obtainable material properties, thus eliminating the need for costly and time-consuming fatigue tests. Simple approximations were able to estimate the strain-life curve with satisfactory accuracy using only monotonic properties. The tested neural network-based model, although yielding acceptable results for the material in question, was found to be overly sensitive to the data sets used for training and showed an inconsistency in estimation of the fatigue life and fatigue properties. The studied continuum damage-based model was able to produce a curve detecting early stages of crack initiation. This model requires more experimental data for calibration than approaches using simple approximations. As a result of the different theories underlying the analyzed methods, the different approaches have different strengths and weaknesses. However, it was found that the group of parametric equations categorized as simple approximations are the easiest for practical use, with their applicability having already been verified for a broad range of materials.
ERIC Educational Resources Information Center
Paula, Cristiane S.; Cunha, Graccielle Rodrigues; Bordini, Daniela; Brunoni, Decio; Moya, Ana Claudia; Bosa, Cleonice Alves; Mari, Jair J.; Cogo-Moreira, Hugo
2018-01-01
Simple and low-cost observational-tools to detect symptoms of Autism Spectrum Disorder (ASD) are still necessary. The OERA is a new assessment tool to screen children eliciting observable behaviors with no substantial knowledge on ASD required. The sample was 99 children aged 3-10: 76 with ASD and 23 without ASD (11/23 had intellectual…
Solid State pH Sensor Based on Light Emitting Diodes (LED) As Detector Platform
Lau, King Tong; Shepherd, R.; Diamond, Danny; Diamond, Dermot
2006-01-01
A low-power, high sensitivity, very low-cost light emitting diode (LED)-based device developed for low-cost sensor networks was modified with bromocresol green membrane to work as a solid-state pH sensor. In this approach, a reverse-biased LED functioning as a photodiode is coupled with a second LED configured in conventional emission mode. A simple timer circuit measures how long (in microsecond) it takes for the photocurrent generated on the detector LED to discharge its capacitance from logic 1 (+5 V) to logic 0 (+1.7 V). The entire instrument provides an inherently digital output of light intensity measurements for a few cents. A light dependent resistor (LDR) modified with similar sensor membrane was also used as a comparison method. Both the LED sensor and the LDR sensor responded to various pH buffer solutions in a similar way to obtain sigmoidal curves expected of the dye. The pKa value obtained for the sensors was found to agree with the literature value.
Media processors using a new microsystem architecture designed for the Internet era
NASA Astrophysics Data System (ADS)
Wyland, David C.
1999-12-01
The demands of digital image processing, communications and multimedia applications are growing more rapidly than traditional design methods can fulfill them. Previously, only custom hardware designs could provide the performance required to meet the demands of these applications. However, hardware design has reached a crisis point. Hardware design can no longer deliver a product with the required performance and cost in a reasonable time for a reasonable risk. Software based designs running on conventional processors can deliver working designs in a reasonable time and with low risk but cannot meet the performance requirements. What is needed is a media processing approach that combines very high performance, a simple programming model, complete programmability, short time to market and scalability. The Universal Micro System (UMS) is a solution to these problems. The UMS is a completely programmable (including I/O) system on a chip that combines hardware performance with the fast time to market, low cost and low risk of software designs.
A simple and low-cost structured illumination microscopy using a pico-projector
NASA Astrophysics Data System (ADS)
Özgürün, Baturay
2018-02-01
Here, development of a low-cost structured illumination microscopy (SIM) based on a pico-projector is presented. The pico-projector consists of independent red, green and blue LEDs that remove need for an external illumination source. Moreover, display element of the pico-projector serves as a pattern generating spatial light modulator. A simple lens group is employed to couple light from the projector to an epi-illumination port of a commercial microscope system. 2D sub SIM images are acquired and synthesized to surpass the diffraction limit using 40x (0.75 NA) objective. Resolution of the reconstructed SIM images is verified with a dye-and-object object and a fixed cell sample.
Kubota, Kenta; Seno, Takeshi; Konishi, Yoshiyuki
2013-11-20
Cerebellar granule neuronal cultures have been used to study the molecular mechanisms underlying neuronal functions, including neuronal morphogenesis. However, a limitation of this system is the difficulty to analyze isolated neurons because these are required to be maintained at a high density. Therefore, in the present study, we aimed to develop a simple and cost-effective method for culturing low-density cerebellar granule neurons. Cerebellar granule cells at two different densities (low- and high-density) were co-cultivated in order for the low-density culture to be supported by the paracrine signals from the high-density culture. This method enabled morphology analysis of isolated cerebellar granule neurons without astrocytic feeder cultures or supplements such as B27. Using this method, we investigated the function of a polarity factor. Studies using hippocampal neurons suggested that glycogen synthase kinase-3 (GSK-3) is an essential regulator of neuronal polarity, and inhibition of GSK-3 results in the formation of multiple axons. Pharmacological inhibitors for GSK-3 (6-bromoindirubin-3'-oxime and lithium chloride) did not cause the formation of multiple axons of cerebellar granule neurons but significantly reduced their length. Consistent results were obtained by introducing kinase-dead form of GSK-3 beta (K85A). These results indicated that GSK-3 is not directly involved in the control of neuronal polarity in cerebellar granule neurons. Overall, this study provides a simple method for culturing low-density cerebellar granule neurons and insights in to the neuronal-type dependent function of GSK-3 in neuronal morphogenesis. © 2013 Elsevier B.V. All rights reserved.
Portolano, Nicola; Watson, Peter J; Fairall, Louise; Millard, Christopher J; Milano, Charles P; Song, Yun; Cowley, Shaun M; Schwabe, John W R
2014-10-16
The expression and purification of large amounts of recombinant protein complexes is an essential requirement for structural biology studies. For over two decades, prokaryotic expression systems such as E. coli have dominated the scientific literature over costly and less efficient eukaryotic cell lines. Despite the clear advantage in terms of yields and costs of expressing recombinant proteins in bacteria, the absence of specific co-factors, chaperones and post-translational modifications may cause loss of function, mis-folding and can disrupt protein-protein interactions of certain eukaryotic multi-subunit complexes, surface receptors and secreted proteins. The use of mammalian cell expression systems can address these drawbacks since they provide a eukaryotic expression environment. However, low protein yields and high costs of such methods have until recently limited their use for structural biology. Here we describe a simple and accessible method for expressing and purifying milligram quantities of protein by performing transient transfections of suspension grown HEK (Human Embryonic Kidney) 293 F cells.
A simple method of fabricating mask-free microfluidic devices for biological analysis
Yi, Xin; Kodzius, Rimantas; Gong, Xiuqing; Xiao, Kang; Wen, Weijia
2010-01-01
We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper to form intricate patterns and differently configured channels for specific purposes. Bonded with cyanoacrylate-based resin, the prepared paper sheet is sandwiched between glass slides (hydrophilic) or polymer-based plates (hydrophobic) to obtain a multilayer structure. In order to examine the chip’s biocompatibility and applicability, protein concentration was measured while DNA capillary electrophoresis was carried out, and both of them show positive results. With the utilization of direct laser cutting and one-step gas-sacrificing techniques, the whole fabrication processes for complicated 2D and 3D microfluidic devices are shorten into several minutes which make it a good alternative of poly(dimethylsiloxane) microfluidic chips used in biological analysis researches. PMID:20890452
Quantitation of the cellular content of saliva and buccal swab samples.
Theda, Christiane; Hwang, Seo Hye; Czajko, Anna; Loke, Yuk Jing; Leong, Pamela; Craig, Jeffrey M
2018-05-02
Buccal swabs and saliva are the two most common oral sampling methods used for medical research. Often, these samples are used interchangeably, despite previous evidence that both contain buccal cells and blood leukocytes in different proportions. For some research, such as epigenetic studies, the cell types contributing to the analysis are highly relevant. We collected such samples from twelve children and twenty adults and, using Papanicolaou staining, measured the proportions of epithelial cells and leukocytes through microscopy. To our knowledge, no studies have compared cellular heterogeneity in buccal swab and saliva samples from adults and children. We confirmed that buccal swabs contained a higher proportion of epithelial cells than saliva and that children have a greater proportion of such cells in saliva compared to adults. At this level of resolution, buccal swabs and saliva contained similar epithelial cell subtypes. Gingivitis in children was associated with a higher proportion of leukocytes in saliva samples but not in buccal swabs. Compared to more detailed and costly methods such as flow cytometry or deconvolution methods used in epigenomic analysis, the procedure described here can serve as a simple and low-cost method to characterize buccal and saliva samples. Microscopy provides a low-cost tool to alert researchers to the presence of oral inflammation which may affect a subset of their samples. This knowledge might be highly relevant to their specific research questions, may assist with sample selection and thus might be crucial information despite the ability of data deconvolution methods to correct for cellular heterogeneity.
NASA Astrophysics Data System (ADS)
Hu, Huan; Siu, Vince S.; Gifford, Stacey M.; Kim, Sungcheol; Lu, Minhua; Meyer, Pablo; Stolovitzky, Gustavo A.
2017-12-01
The recently discovered bactericidal properties of nanostructures on wings of insects such as cicadas and dragonflies have inspired the development of similar nanostructured surfaces for antibacterial applications. Since most antibacterial applications require nanostructures covering a considerable amount of area, a practical fabrication method needs to be cost-effective and scalable. However, most reported nanofabrication methods require either expensive equipment or a high temperature process, limiting cost efficiency and scalability. Here, we report a simple, fast, low-cost, and scalable antibacterial surface nanofabrication methodology. Our method is based on metal-assisted chemical etching that only requires etching a single crystal silicon substrate in a mixture of silver nitrate and hydrofluoric acid for several minutes. We experimentally studied the effects of etching time on the morphology of the silicon nanospikes and the bactericidal properties of the resulting surface. We discovered that 6 minutes of etching results in a surface containing silicon nanospikes with optimal geometry. The bactericidal properties of the silicon nanospikes were supported by bacterial plating results, fluorescence images, and scanning electron microscopy images.
A Simple low-cost device enables four epi-illumination techniques on standard light microscopes.
Ishmukhametov, Robert R; Russell, Aidan N; Wheeler, Richard J; Nord, Ashley L; Berry, Richard M
2016-02-08
Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.
A Simple low-cost device enables four epi-illumination techniques on standard light microscopes
NASA Astrophysics Data System (ADS)
Ishmukhametov, Robert R.; Russell, Aidan N.; Wheeler, Richard J.; Nord, Ashley L.; Berry, Richard M.
2016-02-01
Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.
Rubber-based carbon electrode materials derived from dumped tires for efficient sodium-ion storage.
Wu, Zhen-Yue; Ma, Chao; Bai, Yu-Lin; Liu, Yu-Si; Wang, Shi-Feng; Wei, Xiao; Wang, Kai-Xue; Chen, Jie-Sheng
2018-04-03
The development of sustainable and low cost electrode materials for sodium-ion batteries has attracted considerable attention. In this work, a carbon composite material decorated with in situ generated ZnS nanoparticles has been prepared via a simple pyrolysis of the rubber powder from dumped tires. Upon being used as an anode material for sodium-ion batteries, the carbon composite shows a high reversible capacity and rate capability. A capacity as high as 267 mA h g-1 is still retained after 100 cycles at a current density of 50 mA g-1. The well dispersed ZnS nanoparticles in carbon significantly enhance the electrochemical performance. The carbon composites derived from the rubber powder are proposed as promising electrode materials for low-cost, large-scale energy storage devices. This work provides a new and effective method for the reuse of dumped tires, contributing to the recycling of valuable waste resources.
Production of Oxidation-Resistant Cu-Based Nanoparticles by Wire Explosion
Kawamura, Go; Alvarez, Samuel; Stewart, Ian E.; Catenacci, Matthew; Chen, Zuofeng; Ha, Yoon-Cheol
2015-01-01
The low performance or high cost of commercially available conductive inks limits the advancement of printed electronics. This article studies the explosion of metal wires in aqueous solutions as a simple, low-cost, and environmentally friendly method to prepare metallic nanoparticles consisting of Cu and Cu alloys for use in affordable, highly conductive inks. Addition of 0.2 M ascorbic acid to an aqueous explosion medium prevented the formation of Cu2O shells around Cu nanoparticles, and allowed for the printing of conductive lines directly from these nanoparticles with no post-treatment. Cu alloy nanoparticles were generated from metal wires that were alloyed as purchased, or from two wires of different metals that were twisted together. Cu nanoparticles alloyed with 1% Sn, 5% Ag, 5% Ni and 30% Ni had electrical conductivities similar to Cu but unlike Cu, remained conductive after 24 hrs at 85 °C and 85% RH. PMID:26669447
NASA Astrophysics Data System (ADS)
Jakovels, Dainis; Saknite, Inga; Spigulis, Janis
2014-05-01
Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.
Predicting the propagation of concentration and saturation fronts in fixed-bed filters.
Callery, O; Healy, M G
2017-10-15
The phenomenon of adsorption is widely exploited across a range of industries to remove contaminants from gases and liquids. Much recent research has focused on identifying low-cost adsorbents which have the potential to be used as alternatives to expensive industry standards like activated carbons. Evaluating these emerging adsorbents entails a considerable amount of labor intensive and costly testing and analysis. This study proposes a simple, low-cost method to rapidly assess the potential of novel media for potential use in large-scale adsorption filters. The filter media investigated in this study were low-cost adsorbents which have been found to be capable of removing dissolved phosphorus from solution, namely: i) aluminum drinking water treatment residual, and ii) crushed concrete. Data collected from multiple small-scale column tests was used to construct a model capable of describing and predicting the progression of adsorbent saturation and the associated effluent concentration breakthrough curves. This model was used to predict the performance of long-term, large-scale filter columns packed with the same media. The approach proved highly successful, and just 24-36 h of experimental data from the small-scale column experiments were found to provide sufficient information to predict the performance of the large-scale filters for up to three months. Copyright © 2017 Elsevier Ltd. All rights reserved.
Xu, Qiaojing; Song, Tao; Cui, Wei; Liu, Yuqiang; Xu, Weidong; Lee, Shuit-Tong; Sun, Baoquan
2015-02-11
Hybrid solar cells based on n-Si/poly(3,4-ethylenedioxythiophene):poly(styrene- sulfonate) (PEDOT:PSS) heterojunction promise to be a low cost photovoltaic technology by using simple device structure and easy fabrication process. However, due to the low conductivity of PEDOT:PSS, a metal grid deposited by vacuum evaporation method is still required to enhance the charge collection efficiency, which complicates the device fabrication process. Here, a solution-processed graphene oxide (GO)-welded silver nanowires (AgNWs) transparent conductive electrode (TCE) was employed to replace the vacuum deposited metal grid. A unique "sandwich" structure was developed by embedding an AgNW network between PEDOT:PSS and GO with a figure-of-merit of 8.6×10(-3) Ω(-1), which was even higher than that of sputtered indium tin oxide electrode (6.6×10(-3) Ω(-1)). A champion power conversion efficiency of 13.3% was achieved, because of the decreased series resistance of the TCEs as well as the enhanced built-in potential (Vbi) in the hybrid solar cells. The TCEs were obtained by facile low-temperature solution process method, which was compatible with cost-effective mass production technology.
Fast and low-cost method for VBES bathymetry generation in coastal areas
NASA Astrophysics Data System (ADS)
Sánchez-Carnero, N.; Aceña, S.; Rodríguez-Pérez, D.; Couñago, E.; Fraile, P.; Freire, J.
2012-12-01
Sea floor topography is key information in coastal area management. Nowadays, LiDAR and multibeam technologies provide accurate bathymetries in those areas; however these methodologies are yet too expensive for small customers (fishermen associations, small research groups) willing to keep a periodic surveillance of environmental resources. In this paper, we analyse a simple methodology for vertical beam echosounder (VBES) bathymetric data acquisition and postprocessing, using low-cost means and free customizable tools such as ECOSONS and gvSIG (that is compared with industry standard ArcGIS). Echosounder data was filtered, resampled and, interpolated (using kriging or radial basis functions). Moreover, the presented methodology includes two data correction processes: Monte Carlo simulation, used to reduce GPS errors, and manually applied bathymetric line transformations, both improving the obtained results. As an example, we present the bathymetry of the Ría de Cedeira (Galicia, NW Spain), a good testbed area for coastal bathymetry methodologies given its extension and rich topography. The statistical analysis, performed by direct ground-truthing, rendered an upper bound of 1.7 m error, at 95% confidence level, and 0.7 m r.m.s. (cross-validation provided 30 cm and 25 cm, respectively). The methodology presented is fast and easy to implement, accurate outside transects (accuracy can be estimated), and can be used as a low-cost periodical monitoring method.
Cost analysis of medical device spare parts
Bektemur, Guven; Muzoglu, Nedim; Arici, Mehmet Ali; Karaaslan, Melike Kaya
2018-01-01
Objective: To establish estimation method on budget management of medical device spare parts and to evaluate the cost of medical device spare parts in affiliated hospitals of Istanbul Public Hospital Unions (PHUs). Methods: While this evaluation was performed, the relationship between paid cost for spare parts according to technological development level of device groups and total inventory value was used. Spare part cost analysis was carried out by using the normalized weighted arithmetic average method. Cost analysis of medical equipment spare parts of Istanbul PHUs was performed by using the data retrieved from Ministry of Health Business Intelligence Decision Support System for spending of spare parts in 2015. Results: The medical device spare part groups were categorized based on technological development. Among 1 to 6 PHUs, the cost ratios were acquired for high, middle, low and simple technology group as 17.31 – 40.08%, 29.14 – 43.36%, 22.62 – 27.44% and 8.16 – 11.89%, respectively. The ratio between the spare part and total inventory costs for 1-6 PHUs were calculated as 1.66%, 2.87%, 3.03%, 3.31%, 2.57% and 4.69% respectively. Expected rates based on normalized weighted method were obtained as follows; 5.76%, 4.67%, 5.31%, 4.87%, 4.34% and 4.27%. Conclusion: The expenditure analysis and budget planning for medical device spare parts in PHU could be predicted more accurately by taking into consideration the expected rate calculated by the normal weight method. In additon, the importance of Clinical Engineering Service Units in management of medical devices has been determined. PMID:29805429
Time-of-Flight Measurement of the Speed of Sound in a Metal Bar
ERIC Educational Resources Information Center
Ganci, Salvatore
2016-01-01
A simple setup was designed for a "time-of-flight" measurement of the sound speed in a metal bar. The experiment requires low cost components and is very simple to understand by students. A good use of it is as a demonstration experiment.
ERIC Educational Resources Information Center
Cohen, Sheldon H., Ed.
1983-01-01
Describes a low-cost, high-voltage, two-terminal, constant-current source for student use in electrophoresis experiments (includes circuit diagram) and a simple device for the continuous registering of gas flows. Also lists seven cost-saving tips for chemical reagent, including use decorative stones (purchased from nursery stores) in place of…
Low cost, high tech seed cleaning
Robert P. Karrfalt
2013-01-01
Clean seeds are a great asset in native plant restoration. However, seed cleaning equipment is often too costly for many small operations. This paper introduces how several tools and materials intended for other purposes can be used directly or made into simple machines to clean seeds.
Liu, I-Chen; Chen, Pin-Chuan; Chau, Lai-Kwan; Chang, Guo-En
2018-01-08
We propose and develop an intensity-detection-based refractive-index (RI) sensor for low-cost, rapid RI sensing. The sensor is composed of a polymer bent ridge waveguide (BRWG) structure on a low-cost glass substrate and is integrated with a microfluidic channel. Different-RI solutions flowing through the BRWG sensing region induce output optical power variations caused by optical bend losses, enabling simple and real-time RI detection. Additionally, the sensors are fabricated using rapid and cost-effective vacuum-less processes, attaining the low cost and high throughput required for mass production. A good RI solution of 5.31 10 -4 × RIU -1 is achieved from the RI experiments. This study demonstrates mass-producible and compact RI sensors for rapid and sensitive chemical analysis and biomedical sensing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobson, Arne; Bond, Tami C.; Lam, Nicholoas L.
2013-04-15
Replacing inefficient kerosene lighting with electric lighting or other clean alternatives can rapidly achieve development and energy access goals, save money and reduce climate warming. Many of the 250 million households that lack reliable access to electricity rely on inefficient and dangerous simple wick lamps and other kerosene-fueled light sources, using 4 to 25 billion liters of kerosene annually to meet basic lighting needs. Kerosene costs can be a significant household expense and subsidies are expensive. New information on kerosene lamp emissions reveals that their climate impacts are substantial. Eliminating current annual black carbon emissions would provide a climate benefitmore » equivalent to 5 gigatons of carbon dioxide reductions over the next 20 years. Robust and low-cost technologies for supplanting simple wick and other kerosene-fueled lamps exist and are easily distributed and scalable. Improving household lighting offers a low-cost opportunity to improve development, cool the climate and reduce costs.« less
Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico
Seamans, Yancy; Harner-Jay, Claudia M
2007-01-01
Background Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy – simple ligation and excision (L and E) – appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. Methods The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). Results In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08 – $0.55. Conclusion Based on the results presented, more effective methods of vasectomy – including FI, thermal cautery, and thermal cautery combined with FI – are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods. PMID:17629921
Vectorial strain gauge method using single flexible orthogonal polydimethylsiloxane gratings
NASA Astrophysics Data System (ADS)
Guo, Hao; Tang, Jun; Qian, Kun; Tsoukalas, Dimitris; Zhao, Miaomiao; Yang, Jiangtao; Zhang, Binzhen; Chou, Xiujian; Liu, Jun; Xue, Chenyang; Zhang, Wendong
2016-03-01
A vectorial strain gauge method using a single sensing element is reported based on the double-sided polydimethylsiloxane (PDMS) Fraunhofer diffraction gratings structures. Using O2 plasma treatment steps, orthogonal wrinkled gratings were fabricated on both sides of a pre-strained PDMS film. Diffracted laser spots from this structure have been used to experimentally demonstrate, that any applied strain can be quantitatively characterized in both the x and y directions with an error of less than 0.6% and with a gauge factor of approximately 10. This simple and low cost technology which is completely different from the traditional vectorial strain gauge method, can be applied to surface vectorial strain measurement and multi-axis integrated mechanical sensors.
Ion transport by gating voltage to nanopores produced via metal-assisted chemical etching method
NASA Astrophysics Data System (ADS)
Van Toan, Nguyen; Inomata, Naoki; Toda, Masaya; Ono, Takahito
2018-05-01
In this work, we report a simple and low-cost way to create nanopores that can be employed for various applications in nanofluidics. Nano sized Ag particles in the range from 1 to 20 nm are formed on a silicon substrate with a de-wetting method. Then the silicon nanopores with an approximate 15 nm average diameter and 200 μm height are successfully produced by the metal-assisted chemical etching method. In addition, electrically driven ion transport in the nanopores is demonstrated for nanofluidic applications. Ion transport through the nanopores is observed and could be controlled by an application of a gating voltage to the nanopores.
Ion transport by gating voltage to nanopores produced via metal-assisted chemical etching method.
Van Toan, Nguyen; Inomata, Naoki; Toda, Masaya; Ono, Takahito
2018-05-11
In this work, we report a simple and low-cost way to create nanopores that can be employed for various applications in nanofluidics. Nano sized Ag particles in the range from 1 to 20 nm are formed on a silicon substrate with a de-wetting method. Then the silicon nanopores with an approximate 15 nm average diameter and 200 μm height are successfully produced by the metal-assisted chemical etching method. In addition, electrically driven ion transport in the nanopores is demonstrated for nanofluidic applications. Ion transport through the nanopores is observed and could be controlled by an application of a gating voltage to the nanopores.
Tyson, Adam L.; Hilton, Stephen T.; Andreae, Laura C.
2015-01-01
The cost of 3D printing has reduced dramatically over the last few years and is now within reach of many scientific laboratories. This work presents an example of how 3D printing can be applied to the development of custom laboratory equipment that is specifically adapted for use with the novel brain tissue clearing technique, CLARITY. A simple, freely available online software tool was used, along with consumer-grade equipment, to produce a brain slicing chamber and a combined antibody staining and imaging chamber. Using standard 3D printers we were able to produce research-grade parts in an iterative manner at a fraction of the cost of commercial equipment. 3D printing provides a reproducible, flexible, simple and cost-effective method for researchers to produce the equipment needed to quickly adopt new methods. PMID:25797056
NASA Astrophysics Data System (ADS)
Chaurasia, Pratik Ranjan; Subhash
2018-06-01
An unknown indigenous driller combined the percussion and circulation drilling principles, resulting in the development of low cost, low weight manual boring set in the year 1990-1991/1991-1992, which revolutionized the shallow well drilling technology and made possible to drill about 4.5 million shallow bore wells in the State. This has changed the landscape of irrigated agriculture, changing the life of millions of small and marginal farmers and contributed a lot in increasing crop production and crop productivity. The developed drilling equipment locally known as "Pressure Boring Set" is manually operated, low cost and can be transported on bicycles. Drilling cost is also less. This low cost and simple technology made it possible to drill large number of shallow bore wells in comparatively short time span and less cost, consequently enhancing the rate of increase in irrigated area and in turn crop production and productivity. Cost of the boring set is also low, as compared to traditional sand pump hand boring set and suitable for alluvial areas.
NASA Astrophysics Data System (ADS)
Chaurasia, Pratik Ranjan; Subhash
2018-02-01
An unknown indigenous driller combined the percussion and circulation drilling principles, resulting in the development of low cost, low weight manual boring set in the year 1990-1991/1991-1992, which revolutionized the shallow well drilling technology and made possible to drill about 4.5 million shallow bore wells in the State. This has changed the landscape of irrigated agriculture, changing the life of millions of small and marginal farmers and contributed a lot in increasing crop production and crop productivity. The developed drilling equipment locally known as "Pressure Boring Set" is manually operated, low cost and can be transported on bicycles. Drilling cost is also less. This low cost and simple technology made it possible to drill large number of shallow bore wells in comparatively short time span and less cost, consequently enhancing the rate of increase in irrigated area and in turn crop production and productivity. Cost of the boring set is also low, as compared to traditional sand pump hand boring set and suitable for alluvial areas.
Fourier Analysis of a Vibrating String through a Low-Cost Experimental Setup and a Smartphone
ERIC Educational Resources Information Center
Pereyra, C. J.; Osorio, M.; Laguarda, A.; Gau, D. L.
2018-01-01
In this work we present a simple and low-cost setup to illustrate the dependence of the behaviour of a standing wave in a guitar string with the initial conditions. To do so, we impose two kinds of initial conditions; in the first instance, the initial shape of the string is varied. Secondly, different nodes are imposed on the string. This…
A Very Low Cost BCH Decoder for High Immunity of On-Chip Memories
NASA Astrophysics Data System (ADS)
Seo, Haejun; Han, Sehwan; Heo, Yoonseok; Cho, Taewon
BCH(Bose-Chaudhuri-Hoquenbhem) code, a type of block codes-cyclic codes, has very strong error-correcting ability which is vital for performing the error protection on the memory system. BCH code has many kinds of dual algorithms, PGZ(Pererson-Gorenstein-Zierler) algorithm out of them is advantageous in view of correcting the errors through the simple calculation in t value. However, this is problematic when this becomes 0 (divided by zero) in case ν ≠ t. In this paper, the circuit would be simplified by suggesting the multi-mode hardware architecture in preparation that v were 0~3. First, production cost would be less thanks to the smaller number of gates. Second, lessening power consumption could lengthen the recharging period. The very low cost and simple datapath make our design a good choice in small-footprint SoC(System on Chip) as ECC(Error Correction Code/Circuit) in memory system.
Modular experimental platform for science and applications
NASA Technical Reports Server (NTRS)
Hill, A. S.
1984-01-01
A modularized, standardized spacecraft bus, known as MESA, suitable for a variety of science and applications missions is discussed. The basic bus consists of a simple structural arrangement housing attitude control, telemetry/command, electrical power, propulsion and thermal control subsystems. The general arrangement allows extensive subsystem adaptation to mission needs. Kits provide for the addition of tape recorders, increased power levels and propulsion growth. Both 3-axis and spin stabilized flight proven attitude control subsystems are available. The MESA bus can be launched on Ariane, as a secondary payload for low cost, or on the STS with a PAM-D or other suitable upper stage. Multi-spacecraft launches are possible with either booster. Launch vehicle integration is simple and cost-effective. The low cost of the MESA bus is achieved by the extensive utilization of existing subsystem design concepts and equipment, and efficient program management and test integration techniques.
Application of a low cost ceramic filter to a membrane bioreactor for greywater treatment.
Hasan, Md Mahmudul; Shafiquzzaman, Md; Nakajima, Jun; Ahmed, Abdel Kader T; Azam, Mohammad Shafiul
2015-03-01
The performance of a low cost and simple ceramic filter to a membrane bioreactor (MBR) process was evaluated for greywater treatment. The ceramic filter was submerged in an acrylic cylindrical column bioreactor. Synthetic greywater (prepared by shampoo, dish cleaner and laundry detergent) was fed continuously into the reactor. The filter effluent was obtained by gravitational pressure. The average flux performance was observed to be 11.5 LMH with an average hydraulic retention time of 1.7 days. Complete biodegradation of surfactant (methylene blue active substance removal: 99-100%) as well as high organic removal performance (biochemical oxygen demand: 97-100% and total organic carbon: >88%) was obtained. The consistency of flux (11.5 LMH) indicated that the filter can be operated for a long time without fouling. The application of this simple ceramic filter would make MBR technology cost-effective in developing countries for greywater reclamation and reuse.
Simple refractometer based on in-line fiber interferometers
NASA Astrophysics Data System (ADS)
Esteban, Ó.; Martínez Manuel, R.; Shlyagin, M. G.
2015-09-01
A very simple but accurate optical fiber refractometer based on the Fresnel reflection in the fiber tip and two in-line low-reflective mirrors for light intensity referencing is reported. Each mirror was generated by connecting together 2 fiber sections with FC/PC and FC/APC connectors using the standard FC/PC mating sleeve. For the sensor interrogation, a standard DFB diode laser pumped with a sawtooth-wave current was used. A resolution of 6 x 10-4 was experimentally demonstrated using different liquids. A simple sensor construction and the use of low cost components make the reported system interesting for many applications.
Kumar Dalapati, Goutam; Masudy-Panah, Saeid; Kumar, Avishek; Cheh Tan, Cheng; Ru Tan, Hui; Chi, Dongzhi
2015-01-01
This work demonstrates the fabrication of silicide/silicon based solar cell towards the development of low cost and environmental friendly photovoltaic technology. A heterostructure solar cells using metallic alpha phase (α-phase) aluminum alloyed iron silicide (FeSi(Al)) on n-type silicon is fabricated with an efficiency of 0.8%. The fabricated device has an open circuit voltage and fill-factor of 240 mV and 60%, respectively. Performance of the device was improved by about 7 fold to 5.1% through the interface engineering. The α-phase FeSi(Al)/silicon solar cell devices have promising photovoltaic characteristic with an open circuit voltage, short-circuit current and a fill factor (FF) of 425 mV, 18.5 mA/cm2, and 64%, respectively. The significant improvement of α-phase FeSi(Al)/n-Si solar cells is due to the formation p+−n homojunction through the formation of re-grown crystalline silicon layer (~5–10 nm) at the silicide/silicon interface. Thickness of the regrown silicon layer is crucial for the silicide/silicon based photovoltaic devices. Performance of the α-FeSi(Al)/n-Si solar cells significantly depends on the thickness of α-FeSi(Al) layer and process temperature during the device fabrication. This study will open up new opportunities for the Si based photovoltaic technology using a simple, sustainable, and los cost method. PMID:26632759
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Ningning; Yang, Wei; Suzhou Key Laboratory of Urban Public Safety, Suzhou Institute of University of Science and Technology of China, Suzhou, Jiangsu, 215123
2012-12-15
Graphical abstract: Display Omitted Highlights: ► The GNWs with few defects were synthesized by pyrolyzing PMMA on nickel particles. ► PMMA as carbon source was easily prepared and safe to handle. ► Nickel microparticles were directly used as catalysts without any pre-treatment. ► The method can be used for the low cost and bulk production of graphene. -- Abstract: In this work, multi-layer graphene has been prepared by pyrolyzing poly(methyl methacrylate) (PMMA) on nickel microparticles in the confined microzones formed by organophilic montmorillonite (OMT). Gram-scale of product can be obtained per day by using this method. The obtained graphene wasmore » evaluated by scanning and transmission electron microscopy, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy and thermogravimetric analysis. Pyrolytic conditions such as the system composition of the composites, reaction temperature and the size of catalyst are important parameters affecting the morphology and yield of the final product. Based on the experimental observations and reported literatures, a possible formation process is discussed. The synthesis method of graphene is simple, low-cost, and scalable, which is promising for the application in many fields.« less
Oyola-Reynoso, Stephanie; Heim, Andrew P; Halbertsma-Black, Julian; Zhao, C; Tevis, Ian D; Çınar, Simge; Cademartiri, Rebecca; Liu, Xinyu; Bloch, Jean-Francis; Thuo, Martin M
2015-11-01
Interest in low-cost diagnostic devices has recently gained attention, in part due to the rising cost of healthcare and the need to serve populations in resource-limited settings. A major challenge in the development of such devices is the need for hydrophobic barriers to contain polar bio-fluid analytes. Key approaches in lowering the cost in diagnostics have centered on (i) development of low-cost fabrication techniques/processes, (ii) use of affordable materials, or, (iii) minimizing the need for high-tech tools. This communication describes a simple, low-cost, adaptable, and portable method for patterning paper and subsequent use of the patterned paper in diagnostic tests. Our approach generates hydrophobic regions using a ball-point pen filled with a hydrophobizing molecule suspended in a solvent carrier. An empty ball-point pen was filled with a solution of trichloro perfluoroalkyl silane in hexanes (or hexadecane), and the pen used to draw lines on Whatman® chromatography 1 paper. The drawn regions defined the test zones since the trichloro silane reacts with the paper to give a hydrophobic barrier. The formation of the hydrophobic barriers is reaction kinetic and diffusion-limited, ensuring well defined narrow barriers. We performed colorimetric glucose assays and enzyme-linked immuno-sorbent assay (ELISA) using the created test zones. To demonstrate the versatility of this approach, we fabricated multiple devices on a single piece of paper and demonstrated the reproducibility of assays on these devices. The overall cost of devices fabricated by drawing are relatively lower (
Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico.
Seamans, Yancy; Harner-Jay, Claudia M
2007-07-13
Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy--simple ligation and excision (L and E)--appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08-$0.55. Based on the results presented, more effective methods of vasectomy--including FI, thermal cautery, and thermal cautery combined with FI--are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods.
Polarization digital holographic microscopy using low-cost liquid crystal polarization rotators
NASA Astrophysics Data System (ADS)
Dovhaliuk, Rostyslav Yu
2018-02-01
Polarization imaging methods are actively used to study anisotropic objects. A number of methods and systems, such as imaging polarimeters, were proposed to measure the state of polarization of light that passed through the object. Digital holographic and interferometric approaches can be used to quantitatively measure both amplitude and phase of a wavefront. Using polarization modulation optics, the measurement capabilities of such interference-based systems can be extended to measure polarization-dependent parameters, such as phase retardation. Different kinds of polarization rotators can be used to alternate the polarization of a reference beam. Liquid crystals are used in a rapidly increasing number of different optoelectronic devices. Twisted nematic liquid crystals are widely used as amplitude modulators in electronic displays and light valves or shutter glass. Such devices are of particular interest for polarization imaging, as they can be used as polarization rotators, and due to large-scale manufacturing have relatively low cost. A simple Mach-Zehnder polarized holographic setup that uses modified shutter glass as a polarization rotator is demonstrated. The suggested approach is experimentally validated by measuring retardation of quarter-wave film.
Translating bacterial detection by DNAzymes into a litmus test.
Tram, Kha; Kanda, Pushpinder; Salena, Bruno J; Huan, Shuangyan; Li, Yingfu
2014-11-17
Microbial pathogens pose serious threats to public health and safety, and results in millions of illnesses and deaths as well as huge economic losses annually. Laborious and expensive pathogen tests often represent a significant hindrance to implementing effective front-line preventative care, particularly in resource-limited regions. Thus, there is a significant need to develop low-cost and easy-to-use methods for pathogen detection. Herein, we present a simple and inexpensive litmus test for bacterial detection. The method takes advantage of a bacteria-specific RNA-cleaving DNAzyme probe as the molecular recognition element and the ability of urease to hydrolyze urea and elevate the pH value of the test solution. By coupling urease to the DNAzyme on magnetic beads, the detection of bacteria is translated into a pH increase, which can be readily detected using a litmus dye or pH paper. The simplicity, low cost, and broad adaptability make this litmus test attractive for field applications, particularly in the developing world. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
On simulating flow with multiple time scales using a method of averages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Margolin, L.G.
1997-12-31
The author presents a new computational method based on averaging to efficiently simulate certain systems with multiple time scales. He first develops the method in a simple one-dimensional setting and employs linear stability analysis to demonstrate numerical stability. He then extends the method to multidimensional fluid flow. His method of averages does not depend on explicit splitting of the equations nor on modal decomposition. Rather he combines low order and high order algorithms in a generalized predictor-corrector framework. He illustrates the methodology in the context of a shallow fluid approximation to an ocean basin circulation. He finds that his newmore » method reproduces the accuracy of a fully explicit second-order accurate scheme, while costing less than a first-order accurate scheme.« less
NASA Astrophysics Data System (ADS)
Poggialini, F.; Campanella, B.; Giannarelli, S.; Grifoni, E.; Legnaioli, S.; Lorenzetti, G.; Pagnotta, S.; Safi, A.; Palleschi, V.
2018-03-01
When compared to other analytical techniques, LIBS shows relatively low precision and, generally, high Limits of Detection (LODs). Until recently, the attempts in improving the LIBS performances have been based on the use of more stable/powerful lasers, high sensitivity detectors or controlled environmental parameters. This can hinder the competitiveness of LIBS by increasing the instrumental setup cost and the difficulty of operation. Sample treatment has proved to be a viable and simple way to increase the LIBS signal; in particular, the Nanoparticle-Enhanced Laser Induced Breakdown Spectroscopy (NELIBS) methodology uses a deposition of metal nanoparticles on the sample to greatly increase the emission of the LIBS plasma. In this work, we used a simple, fast, "green" and low-cost method to synthetize silver nanoparticles by using coffee extract as reducing agents for a silver nitrate solution. This allowed us to obtain nanoparticles of about 25 nm in diameter. We then explored the application of such nanoparticles to the NELIBS analysis of metallic samples with a mobile LIBS instrument. By adjusting the laser parameters and optimizing the sample preparation procedure, we obtained a NELIBS signal that is 4 times the LIBS one. This showed the potential of green-synthetized nanoparticle for NELIBS applications and suggests the possibility of an in-situ application of the technique.
Improved Analytical Sensitivity of Lateral Flow Assay using Sponge for HBV Nucleic Acid Detection.
Tang, Ruihua; Yang, Hui; Gong, Yan; Liu, Zhi; Li, XiuJun; Wen, Ting; Qu, ZhiGuo; Zhang, Sufeng; Mei, Qibing; Xu, Feng
2017-05-02
Hepatitis B virus (HBV) infection is a serious public health problem, which can be transmitted through various routes (e.g., blood donation) and cause hepatitis, liver cirrhosis and liver cancer. Hence, it is necessary to do diagnostic screening for high-risk HBV patients in these transmission routes. Nowadays, protein-based technologies have been used for HBV testing, which however involve the issues of large sample volume, antibody instability and poor specificity. Nucleic acid hybridization-based lateral flow assay (LFA) holds great potential to address these limitations due to its low-cost, rapid, and simple features, but the poor analytical sensitivity of LFA restricts its application. In this study, we developed a low-cost, simple and easy-to-use method to improve analytical sensitivity by integrating sponge shunt into LFA to decrease the fluid flow rate. The thickness, length and hydrophobicity of the sponge shunt were sequentially optimized, and achieved 10-fold signal enhancement in nucleic acid testing of HBV as compared to the unmodified LFA. The enhancement was further confirmed by using HBV clinical samples, where we achieved the detection limit of 10 3 copies/ml as compared to 10 4 copies/ml in unmodified LFA. The improved LFA holds great potential for diseases diagnostics, food safety control and environment monitoring at point-of-care.
Brown, Jocelyn; Machen, Heather; Kawaza, Kondwani; Mwanza, Zondiwe; Iniguez, Suzanne; Lang, Hans; Gest, Alfred; Kennedy, Neil; Miros, Robert; Richards-Kortum, Rebecca; Molyneux, Elizabeth; Oden, Maria
2013-01-01
Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design—consumer-grade pumps, medical tubing, and regulators—it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device. PMID:23372661
Design and fabrication of microstrip antenna arrays
NASA Technical Reports Server (NTRS)
1978-01-01
A microstrip array project was conducted to demonstrate the feasibility of designing and fabricating simple, low cost, low sidelobe phased arrays with circular disk microstrip radiating elements. Design data were presented for microstrip elements and arrays including the effects of the protective covers, the mutual interaction between elements, and stripline feed network design. Low cost multilayer laminate fabrication techniques were also investigated. Utilizing this design data two C-band low sidelobe arrays were fabricated and tested: an eight-element linear and a sixty-four element planar array. These arrays incorporated stripline Butler matrix feed networks to produce a low sidelobe broadside beam.
NASA Astrophysics Data System (ADS)
Kuo, Cynthia; Walker, Jesse; Perrig, Adrian
Bluetooth Simple Pairing and Wi-Fi Protected Setup specify mechanisms for exchanging authentication credentials in wireless networks. Both Simple Pairing and Protected Setup support multiple setup mechanisms, which increases security risks and hurts the user experience. To improve the security and usability of these specifications, we suggest defining a common baseline for hardware features and a consistent, interoperable user experience across devices.
Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara
2015-11-01
A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.
Hayashi, Shogo; Naito, Munekazu; Kawata, Shinichi; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Itoh, Masahiro
2016-01-01
Traditionally, surgical training meant on-the-job training with live patients in an operating room. However, due to advancing surgical techniques, such as minimally invasive surgery, and increasing safety demands during procedures, human cadavers have been used for surgical training. When considering the use of human cadavers for surgical training, one of the most important factors is their preservation. In this review, we summarize four preservation methods: fresh-frozen cadaver, formalin, Thiel's, and saturated salt solution methods. Fresh-frozen cadaver is currently the model that is closest to reality, but it also presents myriad problems, including the requirement of freezers for storage, limited work time because of rapid putrefaction, and risk of infection. Formalin is still used ubiquitously due to its low cost and wide availability, but it is not ideal because formaldehyde has an adverse health effect and formalin-embalmed cadavers do not exhibit many of the qualities of living organs. Thiel's method results in soft and flexible cadavers with almost natural colors, and Thiel-embalmed cadavers have been appraised widely in various medical disciplines. However, Thiel's method is relatively expensive and technically complicated. In addition, Thiel-embalmed cadavers have a limited dissection time. The saturated salt solution method is simple, carries a low risk of infection, and is relatively low cost. Although more research is needed, this method seems to be sufficiently useful for surgical training and has noteworthy features that expand the capability of clinical training. The saturated salt solution method will contribute to a wider use of cadavers for surgical training.
Liu, Yingxia; Ma, Yaqian; Wan, Yiqun; Guo, Lan; Wan, Xiaofen
2016-06-01
Most organotin compounds that have been widely used in food packaging materials and production process show serious toxicity effects to human health. In this study, a simple and low-cost method based on high-performance liquid chromatography with inductively coupled plasma mass spectrometry for the simultaneous determination of four organotins in edible vegetable oil samples was developed. Four organotins including dibutyltin dichloride, tributyltin chloride, diphenyltin dichloride, and triphenyltin chloride were simultaneously extracted with methanol using the low-temperature precipitation process. After being concentrated, the extracts were purified by matrix solid-phase dispersion using graphitized carbon black. The experimental parameters such as extraction solvent and clean-up material were optimized. To evaluate the accuracy of the new method, the recoveries were investigated. In addition, a liquid chromatography with tandem mass spectrometry method was also proposed for comparison. The procedures of extracting and purifying samples for the analysis were simple and easy to perform batch operations, also showed good efficiency with lower relative standard deviation. The limits of detection of the four organotins were 0.28-0.59 μg/L, and the limits of quantification of the four organotins were 0.93-1.8 μg/L, respectively. The proposed method was successfully applied to the simultaneous analysis of the four organotins in edible vegetable oil. Some analytes were detected at the level of 2.5-28.8 μg/kg. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Time-of-Flight Measurement of Sound Speed in Air
ERIC Educational Resources Information Center
Ganci, Salvatore
2011-01-01
This paper describes a set of simple experiments with a very low cost using a notebook as a measuring instrument without external hardware. The major purpose is to provide demonstration experiments for schools with very low budgets. (Contains 6 figures.)
A Low Cost VLSI Architecture for Spike Sorting Based on Feature Extraction with Peak Search.
Chang, Yuan-Jyun; Hwang, Wen-Jyi; Chen, Chih-Chang
2016-12-07
The goal of this paper is to present a novel VLSI architecture for spike sorting with high classification accuracy, low area costs and low power consumption. A novel feature extraction algorithm with low computational complexities is proposed for the design of the architecture. In the feature extraction algorithm, a spike is separated into two portions based on its peak value. The area of each portion is then used as a feature. The algorithm is simple to implement and less susceptible to noise interference. Based on the algorithm, a novel architecture capable of identifying peak values and computing spike areas concurrently is proposed. To further accelerate the computation, a spike can be divided into a number of segments for the local feature computation. The local features are subsequently merged with the global ones by a simple hardware circuit. The architecture can also be easily operated in conjunction with the circuits for commonly-used spike detection algorithms, such as the Non-linear Energy Operator (NEO). The architecture has been implemented by an Application-Specific Integrated Circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture is well suited for real-time multi-channel spike detection and feature extraction requiring low hardware area costs, low power consumption and high classification accuracy.
Radiation dose reduction in computed tomography perfusion using spatial-temporal Bayesian methods
NASA Astrophysics Data System (ADS)
Fang, Ruogu; Raj, Ashish; Chen, Tsuhan; Sanelli, Pina C.
2012-03-01
In current computed tomography (CT) examinations, the associated X-ray radiation dose is of significant concern to patients and operators, especially CT perfusion (CTP) imaging that has higher radiation dose due to its cine scanning technique. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) parameter as low as reasonably achievable in data acquisition. However, lowering the mAs parameter will unavoidably increase data noise and degrade CT perfusion maps greatly if no adequate noise control is applied during image reconstruction. To capture the essential dynamics of CT perfusion, a simple spatial-temporal Bayesian method that uses a piecewise parametric model of the residual function is used, and then the model parameters are estimated from a Bayesian formulation of prior smoothness constraints on perfusion parameters. From the fitted residual function, reliable CTP parameter maps are obtained from low dose CT data. The merit of this scheme exists in the combination of analytical piecewise residual function with Bayesian framework using a simpler prior spatial constrain for CT perfusion application. On a dataset of 22 patients, this dynamic spatial-temporal Bayesian model yielded an increase in signal-tonoise-ratio (SNR) of 78% and a decrease in mean-square-error (MSE) of 40% at low dose radiation of 43mA.
Carbon Nanotube-Based Chemiresistive Sensors
Tang, Ruixian; Shi, Yongji; Hou, Zhongyu; Wei, Liangming
2017-01-01
The development of simple and low-cost chemical sensors is critically important for improving human life. Many types of chemical sensors have been developed. Among them, the chemiresistive sensors receive particular attention because of their simple structure, the ease of high precise measurement and the low cost. This review mainly focuses on carbon nanotube (CNT)-based chemiresistive sensors. We first describe the properties of CNTs and the structure of CNT chemiresistive sensors. Next, the sensing mechanism and the performance parameters of the sensors are discussed. Then, we detail the status of the CNT chemiresistive sensors for detection of different analytes. Lastly, we put forward the remaining challenges for CNT chemiresistive sensors and outlook the possible opportunity for CNT chemiresistive sensors in the future. PMID:28420195
Carbon Nanotube-Based Chemiresistive Sensors.
Tang, Ruixian; Shi, Yongji; Hou, Zhongyu; Wei, Liangming
2017-04-18
The development of simple and low-cost chemical sensors is critically important for improving human life. Many types of chemical sensors have been developed. Among them, the chemiresistive sensors receive particular attention because of their simple structure, the ease of high precise measurement and the low cost. This review mainly focuses on carbon nanotube (CNT)-based chemiresistive sensors. We first describe the properties of CNTs and the structure of CNT chemiresistive sensors. Next, the sensing mechanism and the performance parameters of the sensors are discussed. Then, we detail the status of the CNT chemiresistive sensors for detection of different analytes. Lastly, we put forward the remaining challenges for CNT chemiresistive sensors and outlook the possible opportunity for CNT chemiresistive sensors in the future.
Simple and efficient L-band erbium-doped fiber amplifiers for WDM networks
NASA Astrophysics Data System (ADS)
Choi, H. B.; Oh, J. M.; Lee, D.; Ahn, S. J.; Park, B. S.; Lee, S. B.
2002-11-01
The performance of L-band erbium-doped fiber amplifier (EDFA) of a simple structure with a fiber Bragg grating (FBG) was investigated. The injected C-band ASE by the FBG offers low-cost amplification and greatly improves the efficiency of the EDFA. There are 9 and 4 dB improvements with the FBG at 1587 nm, at low and high input, respectively. The flat gain of 18 dB, up to a total input of -5 dBm at 150 mW of 980 nm pump, is obtained over 30 nm with less than ±0.5 dB gain variations without any gain equalizer. The proposed EDFA provides a cost-effective solution for wavelength division multiplexing systems.
The low-cost microwave plasma sources for science and industry applications
NASA Astrophysics Data System (ADS)
Tikhonov, V. N.; Aleshin, S. N.; Ivanov, I. A.; Tikhonov, A. V.
2017-11-01
Microwave plasma torches proposed in the world market are built according to a scheme that can be called classical: power supply - magnetron head - microwave isolator with water load - reflected power meter - matching device - actual plasma torch - sliding short circuit. The total cost of devices from this list with a microwave generator of 3 kW in the performance, for example, of SAIREM (France), is about 17,000 €. We have changed the classical scheme of the microwave plasmathrone and optimised design of the waveguide channel. As a result, we can supply simple and reliable sources of microwave plasma (complete with our low-budget microwave generator up to 3 kW and a simple plasmathrone of atmospheric pressure) at a price from 3,000 €.
Yu, Chunmei; Zhu, Zhenkun; Wang, Li; Wang, Qiuhong; Bao, Ning; Gu, Haiying
2014-03-15
Developing cost-effective and simple analysis tools is of vital importance for practical applications in bioanalysis. In this work, a new disposable electrochemical cell sensor with low cost and simple fabrication was proposed to study the electrochemical behavior of leukemia K562 cells and the effect of anticancer drugs on cell viability. The analytical device was integrated by using ITO glass as the substrate of working electrodes and paper as the electrolytic cell. The cyclic voltammetry of the K562 cells at the disposable electrode exhibited an irreversible anodic peak and the peak current is proportional to the cell number. This anodic peak is attributed to the oxidation of guanine in cells involving two protons per transfer of two electrons. For the drug sensitivity tests, arsenic trioxide and cyclophosphamide were added to cell culture media. As a result, the electrochemical responses of the K562 cells decreased significantly. The cytotoxicity curves and results obtained corresponded well with the results of CCK-8 assays. In comparison to conventional methods, the proposed method is simple, rapid and inexpensive. More importantly, the developed sensor is supposed to be a single-use disposable device and electrodes were prepared "as new" for each experiment. We think that such disposable electrodes with these characteristics are suitable for experimental study with cancer cells or other types of pathogens for disease diagnosis, drug selection and on-site monitoring. © 2013 Elsevier B.V. All rights reserved.
Kelishadi, Roya; Ziaee, Vahid; Ardalan, Gelayol; Namazi, Ascieh; Noormohammadpour, Pardis; Ghayour-Mobarhan, Majid; Sadraei, Hoda; Mirmoghtadaee, Parisa; Poursafa, Parinaz
2010-01-01
Objective To provide a low-cost and simple model of culturally-appropriate and low cost facilities for improvement of physical activity for girls and their mothers through an after-school program and to determine the changes in anthropometric indexes after this trial. Methods This national study was conducted in 2006-2007 in 7 provinces with different socioeconomic situations in Iran. Female students who studied in the 7th through 10th grade and their mothers were selected by random cluster sampling. In each province, 24 sessions of after-school aerobic physical activity were held for 90 minutes, two days a week, and 3 months long at school sites in the afternoon. Findings The study comprised 410 participants (204 mothers and 206 daughters), with a mean age of 15.86±1.01 and 40.71±6.3 years in girls and their mothers, respectively. The results of the focus group discussions showed that in general, both mothers and daughters were satisfied from the program and found it feasible and successful. After the trial, the indexes of generalized and abdominal obesity improved significantly both in girls and in their mothers (P-value <0.0001 for weight, body mass index and waist circumference). Conclusion Our findings may provide a low-cost and simple effective model of motivation for physical activity with targeted interventions for girls and their mothers. We suggest that the success of this trial might be a result of bonding and accompaniment of mothers and daughters. Such model can be integrated in the existing health and education systems to increase the physical activity level. PMID:23056741
Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P.; Ko, Seung Hwan
2012-01-01
Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition– and photolithography-based conventional metal patterning processes. The “digital” nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays. PMID:22900011
Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P; Ko, Seung Hwan
2012-01-01
Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition- and photolithography-based conventional metal patterning processes. The "digital" nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays.
A Low Cost Course Information Syndication System
ERIC Educational Resources Information Center
Ajayi, A. O.; Olajubu, E. A.; Bello, S. A.; Soriyan, H. A.; Obamuyide, A. V.
2011-01-01
This study presents a cost effective, reliable, and convenient mobile web-based system to facilitate the dissemination of course information to students, to support interaction that goes beyond the classroom. The system employed the Really Simple Syndication (RSS) technology and was developed using Rapid Application Development (RAD) methodology.…
Simulation Based Low-Cost Composite Process Development at the US Air Force Research Laboratory
NASA Technical Reports Server (NTRS)
Rice, Brian P.; Lee, C. William; Curliss, David B.
2003-01-01
Low-cost composite research in the US Air Force Research Laboratory, Materials and Manufacturing Directorate, Organic Matrix Composites Branch has focused on the theme of affordable performance. Practically, this means that we use a very broad view when considering the affordability of composites. Factors such as material costs, labor costs, recurring and nonrecurring manufacturing costs are balanced against performance to arrive at the relative affordability vs. performance measure of merit. The research efforts discussed here are two projects focused on affordable processing of composites. The first topic is the use of a neural network scheme to model cure reaction kinetics, then utilize the kinetics coupled with simple heat transport models to predict, in real-time, future exotherms and control them. The neural network scheme is demonstrated to be very robust and a much more efficient method that mechanistic cure modeling approach. This enables very practical low-cost processing of thick composite parts. The second project is liquid composite molding (LCM) process simulation. LCM processing of large 3D integrated composite parts has been demonstrated to be a very cost effective way to produce large integrated aerospace components specific examples of LCM processes are resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM), and other similar approaches. LCM process simulation is a critical part of developing an LCM process approach. Flow simulation enables the development of the most robust approach to introducing resin into complex preforms. Furthermore, LCM simulation can be used in conjunction with flow front sensors to control the LCM process in real-time to account for preform or resin variability.
Low cost label-free live cell imaging for biological samples
NASA Astrophysics Data System (ADS)
Seniya, C.; Towers, C. E.; Towers, D. P.
2017-02-01
This paper reports the progress to develop a practical phase measuring microscope offering new capabilities in terms of phase measurement accuracy and quantification of cell:cell interactions over the longer term. A novel, low cost phase interference microscope for imaging live cells (label-free) is described. The method combines the Zernike phase contrast approach with a dual mirror design to enable phase modulation between the scattered and un-scattered optical fields. Two designs are proposed and demonstrated, one of which retains the common path nature of Zernike's original microscopy concept. In both setups the phase shift is simple to control via a piezoelectric driven mirror in the back focal plane of the imaging system. The approach is significantly cheaper to implement than those based on spatial light modulators (SLM) at approximately 20% of the cost. A quantitative assessment of the performance of a set of phase shifting algorithms is also presented, specifically with regard to broad bandwidth illumination in phase contrast microscopy. The simulation results show that the phase measurement accuracy is strongly dependent on the algorithm selected and the optical path difference in the sample.
Reducing the healthcare costs of urban air pollution: the South African experience.
Leiman, Anthony; Standish, Barry; Boting, Antony; van Zyl, Hugo
2007-07-01
Air pollutants often have adverse effects on human health. This paper investigates and ranks a set of policy and technological interventions intended to reduce such health costs in the high population density areas of South Africa. It initially uses a simple benefit-cost rule, later extended to capture sectoral employment impacts. Although the focus of state air quality legislation is on industrial pollutants, the most efficient interventions were found to be at household level. These included such low-cost interventions as training householders to place kindling above rather than below the coal in a fireplace and insulating roofs. The first non-household policies to emerge involved vehicle fuels and technologies. Most proposed industrial interventions failed a simple cost-benefit test. The paper's policy messages are that interventions should begin with households and that further industry controls are not yet justifiable in their present forms as these relate to the health care costs of such interventions.
A Simple Method to Improve Autonomous GPS Positioning for Tractors
Gomez-Gil, Jaime; Alonso-Garcia, Sergio; Gómez-Gil, Francisco Javier; Stombaugh, Tim
2011-01-01
Error is always present in the GPS guidance of a tractor along a desired trajectory. One way to reduce GPS guidance error is by improving the tractor positioning. The most commonly used ways to do this are either by employing more precise GPS receivers and differential corrections or by employing GPS together with some other local positioning systems such as electronic compasses or Inertial Navigation Systems (INS). However, both are complex and expensive solutions. In contrast, this article presents a simple and low cost method to improve tractor positioning when only a GPS receiver is used as the positioning sensor. The method is based on placing the GPS receiver ahead of the tractor, and on applying kinematic laws of tractor movement, or a geometric approximation, to obtain the midpoint position and orientation of the tractor rear axle more precisely. This precision improvement is produced by the fusion of the GPS data with tractor kinematic control laws. Our results reveal that the proposed method effectively reduces the guidance GPS error along a straight trajectory. PMID:22163917
NASA Astrophysics Data System (ADS)
Aligholi, Saeed; Lashkaripour, Gholam Reza; Ghafoori, Mohammad
2017-01-01
This paper sheds further light on the fundamental relationships between simple methods, rock strength, and brittleness of igneous rocks. In particular, the relationship between mechanical (point load strength index I s(50) and brittleness value S 20), basic physical (dry density and porosity), and dynamic properties (P-wave velocity and Schmidt rebound values) for a wide range of Iranian igneous rocks is investigated. First, 30 statistical models (including simple and multiple linear regression analyses) were built to identify the relationships between mechanical properties and simple methods. The results imply that rocks with different Schmidt hardness (SH) rebound values have different physicomechanical properties or relations. Second, using these results, it was proved that dry density, P-wave velocity, and SH rebound value provide a fine complement to mechanical properties classification of rock materials. Further, a detailed investigation was conducted on the relationships between mechanical and simple tests, which are established with limited ranges of P-wave velocity and dry density. The results show that strength values decrease with the SH rebound value. In addition, there is a systematic trend between dry density, P-wave velocity, rebound hardness, and brittleness value of the studied rocks, and rocks with medium hardness have a higher brittleness value. Finally, a strength classification chart and a brittleness classification table are presented, providing reliable and low-cost methods for the classification of igneous rocks.
Advancements in noncontact, multiparameter physiological measurements using a webcam.
Poh, Ming-Zher; McDuff, Daniel J; Picard, Rosalind W
2011-01-01
We present a simple, low-cost method for measuring multiple physiological parameters using a basic webcam. By applying independent component analysis on the color channels in video recordings, we extracted the blood volume pulse from the facial regions. Heart rate (HR), respiratory rate, and HR variability (HRV, an index for cardiac autonomic activity) were subsequently quantified and compared to corresponding measurements using Food and Drug Administration-approved sensors. High degrees of agreement were achieved between the measurements across all physiological parameters. This technology has significant potential for advancing personal health care and telemedicine.
Simple TLC-screening of acylglycerol levels in biodiesel as an alternative to GC determination.
Fontana, J D; Zagonel, G; Vechiatto, W W; Costa, B J; Laurindo, J C; Fontana, R; Pelisson, L; Jorge, B H; Lanças, F M
2009-10-01
Thin layer chromatography (TLC) stained with hot acidic p-anisaldehyde, is an interesting, fast, and low-cost technique to monitor main lipid contaminants such as triacylglycerols, diacylglycerols, and monoacylglycerols in biodiesel. These acylglycerols are detectable by the proposed planar chromatographic method, provided the content of the contaminants exceeds the limits recommended by the international norms applicable to biodiesel quality/specification, namely 0.25% in mass for total combined glycerin. The TLC data are confirmed by gas chromatography of the methyl esters of soy oil.
Multiple testing corrections in quantitative proteomics: A useful but blunt tool.
Pascovici, Dana; Handler, David C L; Wu, Jemma X; Haynes, Paul A
2016-09-01
Multiple testing corrections are a useful tool for restricting the FDR, but can be blunt in the context of low power, as we demonstrate by a series of simple simulations. Unfortunately, in proteomics experiments low power can be common, driven by proteomics-specific issues like small effects due to ratio compression, and few replicates due to reagent high cost, instrument time availability and other issues; in such situations, most multiple testing corrections methods, if used with conventional thresholds, will fail to detect any true positives even when many exist. In this low power, medium scale situation, other methods such as effect size considerations or peptide-level calculations may be a more effective option, even if they do not offer the same theoretical guarantee of a low FDR. Thus, we aim to highlight in this article that proteomics presents some specific challenges to the standard multiple testing corrections methods, which should be employed as a useful tool but not be regarded as a required rubber stamp. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Teaching radio astronomy with Affordable Small Radio Telescope (ASRT)
NASA Astrophysics Data System (ADS)
Joshi, Bhal Chandra
A simple, easy to build and portable radio telescope, called Affordable Small Radio Telescope (ASRT), has been developed by the Radio Physics Laboratory (RPL), a radio astronomy teaching unit associated with the National Centre for Radio Astrophysics (TIFR) and Inter-University Centre for Astronomy and Astrophysics (IUCAA), which are two premier astronomy institutes in India. ASRT consists of off-the-shelf available Direct to Home television dishes and is easy to assemble. Our design is scalable from simple very low cost telescope to more complex yet moderately costing instrument. ASRT provides a platform for demonstrating radio physics concepts through simple hands-on experiment as well as for carrying out solar monitoring by college/University students. The presentation will highlight the concept of ASRT and the different experiments that can be carried out using it. The solar monitoring observations will be discussed along-with details of methods for calibrating these measurements. The pedagogical usefulness of ASRT in introducing undergraduatephysics students to astrophysics, measurements and analysis methods used in radio astronomy will also be discussed. Use of ASRT in the last three years in the programs of RPL, namely the annual Radio Astronomy Winter School for College students (RAWSC) and Pulsar Observing for Students (POS) is also presented. This year a new program was initiated to form a virtual group of an ASRT community, which will not only share their measurements, but also think of improving the pedagogical usefulness of ASRT by innovative experiments. This initiative is presented with the best practices drawn from our experience in using ASRT as a tool for student training in space sciences. The talk will also point out future ideas in involving a larger body of students in simple radio astronomy experiments with the ASRT, which RPL is likely to nucleate as part of its mandate.
Applications of thin-film sandwich crystallization platforms.
Axford, Danny; Aller, Pierre; Sanchez-Weatherby, Juan; Sandy, James
2016-04-01
Examples are shown of protein crystallization in, and data collection from, solutions sandwiched between thin polymer films using vapour-diffusion and batch methods. The crystallization platform is optimal for both visualization and in situ data collection, with the need for traditional harvesting being eliminated. In wells constructed from the thinnest plastic and with a minimum of aqueous liquid, flash-cooling to 100 K is possible without significant ice formation and without any degradation in crystal quality. The approach is simple; it utilizes low-cost consumables but yields high-quality data with minimal sample intervention and, with the very low levels of background X-ray scatter that are observed, is optimal for microcrystals.
GPS=A Good Candidate for Data Assimilation?
NASA Technical Reports Server (NTRS)
Poli, P.; Joiner, J.; Kursinski, R.; Einaudi, Franco (Technical Monitor)
2000-01-01
The Global Positioning System (GPS) enables positioning anywhere about our planet. The microwave signals sent by the 24 transmitters are sensitive to the atmosphere. Using the radio occultation technique, it is possible to perform soundings, with a Low Earth Orbiter (700 km) GPS receiver. The insensitiveness to clouds and aerosols, the relatively high vertical resolution (1.5 km), the self-calibration and stability of the GPS make it a priori a potentially good observing system candidate for data assimilation. A low-computing cost simple method to retrieve both temperature and humidity will be presented. Comparisons with radiosonde show the capability of the GPS to resolve the tropopause. Options for using GPS for data assimilation and remaining issues will be discussed.
A novel method of sensing temperatures of magnet coils of SINP-MaPLE plasma device
NASA Astrophysics Data System (ADS)
Pal, A. M.; Bhattacharya, S.; Biswas, S.; Basu, S.; Pal, R.
2014-03-01
A set of 36 magnet coils is used to produce a continuous, uniform magnetic field of about 0.35 Tesla inside the vacuum chamber of the MaPLE Device, a linear laboratory plasma device (3 m long and 0.30 m in diameter) built for studying basic magnetized plasma physics phenomena. To protect the water cooled-coils from serious damage due to overheating temperatures of all the coils are monitored electronically using low cost temperature sensor IC chips, a technique first being used in similar magnet system. Utilizing the Parallel Port of a Personal Computer a novel scheme is used to avoid deploying microprocessor that is associated with involved circuitry and low level programming to address and control the large number of sensors. The simple circuits and a program code to implement the idea are developed, tested and presently in operation. The whole arrangement comes out to be not only attractive, but also simple, economical and easy to install elsewhere.
Off-axis holographic laser speckle contrast imaging of blood vessels in tissues
NASA Astrophysics Data System (ADS)
Abdurashitov, Arkady; Bragina, Olga; Sindeeva, Olga; Sergey, Sindeev; Semyachkina-Glushkovskaya, Oxana V.; Tuchin, Valery V.
2017-09-01
Laser speckle contrast imaging (LSCI) has become one of the most common tools for functional imaging in tissues. Incomplete theoretical description and sophisticated interpretation of measurement results are completely sidelined by a low-cost and simple hardware, fastness, consistent results, and repeatability. In addition to the relatively low measuring volume with around 700 μm of the probing depth for the visible spectral range of illumination, there is no depth selectivity in conventional LSCI configuration; furthermore, in a case of high NA objective, the actual penetration depth of light in tissues is greater than depth of field (DOF) of an imaging system. Thus, the information about these out-of-focus regions persists in the recorded frames but cannot be retrieved due to intensity-based registration method. We propose a simple modification of LSCI system based on the off-axis holography to introduce after-registration refocusing ability to overcome both depth-selectivity and DOF problems as well as to get the potential possibility of producing a cross-section view of the specimen.
Photoacoustic sensor for medical diagnostics
NASA Astrophysics Data System (ADS)
Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann
2004-03-01
The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.
Profitable capitation requires accurate costing.
West, D A; Hicks, L L; Balas, E A; West, T D
1996-01-01
In the name of costing accuracy, nurses are asked to track inventory use on per treatment basis when more significant costs, such as general overhead and nursing salaries, are usually allocated to patients or treatments on an average cost basis. Accurate treatment costing and financial viability require analysis of all resources actually consumed in treatment delivery, including nursing services and inventory. More precise costing information enables more profitable decisions as is demonstrated by comparing the ratio-of-cost-to-treatment method (aggregate costing) with alternative activity-based costing methods (ABC). Nurses must participate in this costing process to assure that capitation bids are based upon accurate costs rather than simple averages.
NASA Astrophysics Data System (ADS)
Kingston, J.; Hobbs, S.; Roberts, P.; Juanes-Vallejo, C.; Robinson, F.; Sewell, R.; Snapir, B.; Llop, J. Virgili; Patel, M.
2014-07-01
TechDemoSat-1 is a UK-funded technology demonstration satellite, carrying 8 payloads provided by UK organisations, which is due to be launched in the first quarter of 2014. Cranfield University has supplied a De-Orbit Sail (DOS) payload to allow the mission to comply with end-of-life debris mitigation guidelines. The payload provides a passive, simple, and low-cost means of mitigating debris proliferation in Low Earth Orbit, by enhancing spacecraft aerodynamic drag at end-of-life and reducing time to natural orbital decay and re-entry. This paper describes the use of small commercial electro-explosive devices (EEDs), produced for use as parachute tether-cutters in reserve chute deployment systems, as low-cost but high-reliability release mechanisms for space applications. A testing campaign, including thermal vacuum and mechanical vibration, is described, which demonstrates the suitability of these CYPRES™ cutters, with a flexible Kevlar clamp band, for use as a hold-down and release mechanism (HDRM) for a deployable de-orbit sail. The HDRM is designed to be three-failure-tolerant, highly reliable, yet simple and low-cost.
Dawan, Phanphruk; Satarpai, Thiphol; Tuchinda, Patoomratana; Shiowatana, Juwadee; Siripinyanond, Atitaya
2017-01-01
A new analytical platform based on the use of thin-layer chromatography (TLC) coupled with paper-based analytical device (PAD) was developed for the determination of total capsaicinoids in chilli samples. This newly developed TLC-PAD is simple and low-cost without any requirement of special instrument or skillful person. The analysis consisted of two steps, i.e., extraction of capsaicinoids from chilli samples by using ethanol as solvent and separation of capsaicinoids by thin-layer chromatography (TLC) and elution of capsaicinoids from the TLC plate with in situ colorimetric detection of capsaicinoids on the PAD. For colorimetric detection, Folin-Ciocalteu reagent was used to detect phenolic functional group of capsaicinoids yielding the blue color. The blue color on the PAD was imaged by a scanner followed by evaluation of its grayscale intensity value by ImageJ program. This newly developed TLC-PAD method provided a linear range from 50 to 1000mgL -1 capsaicinoids with the limit of detection as low as 50mgL -1 capsaicinoids. The proposed method was applied to determine capsaicinoids in dried chilli and seasoning powder samples and the results were in good agreement with those obtained by HPLC method. Copyright © 2016 Elsevier B.V. All rights reserved.
A Simple and Reliable Method of Design for Standalone Photovoltaic Systems
NASA Astrophysics Data System (ADS)
Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.
2017-06-01
Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.
Planet-disc interactions with Discontinuous Galerkin Methods using GPUs
NASA Astrophysics Data System (ADS)
Velasco Romero, David A.; Veiga, Maria Han; Teyssier, Romain; Masset, Frédéric S.
2018-05-01
We present a two-dimensional Cartesian code based on high order discontinuous Galerkin methods, implemented to run in parallel over multiple GPUs. A simple planet-disc setup is used to compare the behaviour of our code against the behaviour found using the FARGO3D code with a polar mesh. We make use of the time dependence of the torque exerted by the disc on the planet as a mean to quantify the numerical viscosity of the code. We find that the numerical viscosity of the Keplerian flow can be as low as a few 10-8r2Ω, r and Ω being respectively the local orbital radius and frequency, for fifth order schemes and resolution of ˜10-2r. Although for a single disc problem a solution of low numerical viscosity can be obtained at lower computational cost with FARGO3D (which is nearly an order of magnitude faster than a fifth order method), discontinuous Galerkin methods appear promising to obtain solutions of low numerical viscosity in more complex situations where the flow cannot be captured on a polar or spherical mesh concentric with the disc.
Algal biofuels: challenges and opportunities.
Leite, Gustavo B; Abdelaziz, Ahmed E M; Hallenbeck, Patrick C
2013-10-01
Biodiesel production using microalgae is attractive in a number of respects. Here a number of pros and cons to using microalgae for biofuels production are reviewed. Algal cultivation can be carried out using non-arable land and non-potable water with simple nutrient supply. In addition, algal biomass productivities are much higher than those of vascular plants and the extractable content of lipids that can be usefully converted to biodiesel, triacylglycerols (TAGs) can be much higher than that of the oil seeds now used for first generation biodiesel. On the other hand, practical, cost-effective production of biofuels from microalgae requires that a number of obstacles be overcome. These include the development of low-cost, effective growth systems, efficient and energy saving harvesting techniques, and methods for oil extraction and conversion that are environmentally benign and cost-effective. Promising recent advances in these areas are highlighted. Copyright © 2013 Elsevier Ltd. All rights reserved.
Paper-Based Inkjet-Printed Flexible Electronic Circuits.
Wang, Yan; Guo, Hong; Chen, Jin-Ju; Sowade, Enrico; Wang, Yu; Liang, Kun; Marcus, Kyle; Baumann, Reinhard R; Feng, Zhe-Sheng
2016-10-05
Printed flexible electronics have been widely studied for their potential use in various applications. In this paper, a simple, low-cost method of fabricating flexible electronic circuits with high conductivity of 4.0 × 10 7 S·m -1 (about 70% of the conductivity of bulk copper) is demonstrated. Teslin paper substrate is treated with stannous chloride (SnCl 2 ) colloidal solution to reduce the high ink absorption rate, and then the catalyst ink is inkjet-printed on its surface, followed by electroless deposition of copper at low temperature. In spite of the decrease in conductance to some extent, electronic circuits fabricated by this method can maintain function even under various folding angles or after repeated folding. This developed technology has great potential in a variety of applications, such as three-dimensional devices and disposable RFID tags.
A Budget Tree Improvement Program
Hans Nienstaedt; Hyun Kang
1983-01-01
In an Upper Peninsula Michigan test of simple design, white spruce of a Beachburg, Ontaria provenance grew 17.5 percent taller than white spruce from the Ottawa N.F. The paper describes how to convert such tests to low-cost, low-risk, highly flexible improvement programs. The approach is applicable to other species of low priority.
Deshmukh, Rupali; Calvo, Micha; Schreck, Murielle; Tervoort, Elena; Sologubenko, Alla S; Niederberger, Markus
2018-06-20
We report a solution-phase approach to the synthesis of crystalline copper nanowires (Cu NWs) with an aspect ratio >1000 via a new catalytic mechanism comprising copper ions. The synthesis involves the reaction between copper(II) chloride and copper(II) acetylacetonate in a mixture of oleylamine and octadecene. Reaction parameters such as the molar ratio of precursors as well as the volume ratio of solvents offer the possibility to tune the morphology of the final product. A simple low-cost spray deposition method was used to fabricate Cu NW films on a glass substrate. Post-treatment under reducing gas (5% H 2 + 95% N 2 ) atmosphere resulted in Cu NW films with a low sheet resistance of 24.5 Ω/sq, a transmittance of T = 71% at 550 nm (including the glass substrate), and a high oxidation resistance. Moreover, the conducting Cu NW networks on a glass substrate can easily be transferred onto a polycarbonate substrate using a simple hot-press transfer method without compromising on the electrical performance. The resulting flexible transparent electrodes show excellent flexibility ( R/ R o < 1.28) upon bending to curvatures of 1 mm radius.
Eslamian, Morteza; Zabihi, Fatemeh
2015-12-01
A simple, low-cost, versatile, and potentially scalable casting method is proposed for the fabrication of micro- and nano-thin films, herein termed as ultrasonic "substrate vibration-assisted drop casting" (SVADC). The impingement of a solution drop onto a substrate in a simple process called drop casting, usually results in spreading of the liquid solution and the formation of a non-uniform thin solid film after solvent evaporation. Our previous and current supporting results, as well as few similar reports by others, confirm that imposing ultrasonic vibration on the substrate can simply convert the uncontrollable drop casting method into a controllable coating technique. Therefore, the SVADC may be used to fabricate an array of emerging thin-film solar cells, such as polymer, perovskite, and quantum-dot solar cells, as well as other small thin-film devices, in a roll-to-roll and automated fabrication process. The preliminary results demonstrate a ten-fold increase in electrical conductivity of PSS made by SVADC compared with the film made by conventional drop casting. Also, simple planar perovskite solar cells made here using SVADC show promising performance with an efficiency of over 3 % for a simple structure without performing process optimization or using expensive materials and treatments.
NASA Astrophysics Data System (ADS)
Vovides, Alejandra G.; Marín-Castro, Beatriz; Barradas, Guadalupe; Berger, Uta; López-Portillo, Jorge
2016-12-01
This work presents the development of a low-cost method to measure the length cable roots of black mangrove (Avicennia germinans) trees to define the boundaries of central part of the anchoring root system (CPRS) without the need to fully expose root systems. The method was tested to locate and measure the length shallow woody root systems. An ultrasonic Doppler fetal monitor (UD) and a stock of steel rods (SR) were used to probe root locations without removing sediments from the surface, measure their length and estimate root-soil plate dimensions. The method was validated by comparing measurements with root lengths taken through direct measurement of excavated cable roots and from root-soil plate radii (exposed root-soil material when a tree tips over) of five up-rooted trees with stem diameters (D130) ranging between 10 and 50 cm. The mean CPRS radius estimated with the use of the Doppler was directly correlated with tree stem diameter and was not significantly different from the root-soil plate mean radius measured from up-rooted trees or from CPRS approximated by digging trenches. Our method proved to be effective and reliable in following cable roots for large amounts of trees of both black and white mangrove trees. In a period of 40 days of work, three people were capable of measuring 648 roots belonging to 81 trees, out of which 37% were found grafted to other tree roots. This simple method can be helpful in following shallow root systems with minimal impact and help map root connection networks of grafted trees.
Capmany, José; Mora, José; Ortega, Beatriz; Pastor, Daniel
2005-03-07
We propose and experimentally demonstrate two configurations of photonic filters for the processing of microwave signals featuring tunability, reconfigurability and negative coefficients based on the use of low cost optical sources. The first option is a low power configuration based on spectral slicing of a broadband source. The second is a high power configuration based on fixed lasers. Tunability, reconfigurability and negative coefficients are achieved by means of a MEMS cross-connect, a variable optical attenuator array and simple 2x2 switches respectively.
A Simple "in Vitro" Culture of Freshwater Prawn Embryos for Laboratory Investigations
ERIC Educational Resources Information Center
Porntrai, Supaporn; Damrongphol, Praneet
2008-01-01
Giant freshwater prawn ("Macrobrachium rosenbergii" De Man) embryos can be cultured "in vitro" to hatching in 15% (v/v) artificial seawater (ASW). This technique can be applied as a bioassay for testing toxicity or for the effects of various substances on embryo development and can be used as a simple and low-cost model for…
Chorioallantoic membrane for in vivo investigation of tissue-engineered construct biocompatibility.
Baiguera, Silvia; Macchiarini, Paolo; Ribatti, Domenico
2012-07-01
In tissue engineering approach, the scaffold plays a key role for a suitable outcome of cell-scaffold interactions and for the success of tissue healing and regeneration. As a consequence, the characterization of scaffold properties and the in vivo evaluation of tissue responses and effects result to be essential in the development of suitable implantable device. Among the in vivo methods, the chick embryo chorioallantoic membrane (CAM) assay represents a rather simple and cost-effective procedure to study the biocompatibility responses of graft materials. CAM is indeed characterized by low experiment costs, simplicity, relative speed in obtaining the expected results, limited ethical concern, no need of high-level technical skill, and the absence of a mature immune system, resulting in an inexpensive, simple, and practical method to evaluate and characterize tissue-engineered constructs. The results till now obtained suggest that CAM assay can be used as a pre-screening assay, before in vivo animal studies, to determine whether the scaffold is liable to cause an adverse reaction and to evaluate its future enhancement of existing materials for tissue engineering. A review of the more recent results related to the use of CAM for in vivo biomaterial property evaluation is herein reported. Copyright © 2012 Wiley Periodicals, Inc.
Raspberry Pi: a 35-dollar device for viewing DICOM images.
Paiva, Omir Antunes; Moreira, Renata de Oliveira
2014-01-01
Raspberry Pi is a low-cost computer created with educational purposes. It uses Linux and, most of times, freeware applications, particularly a software for viewing DICOM images. With an external monitor, the supported resolution (1920 × 1200 pixels) allows for the set up of simple viewing workstations at a reduced cost.
Chu, Steven
2017-12-27
By installing a cool roof at DOE, the federal government and Secretary Chu are helping to educate families and businesses about the important energy and cost savings that can come with this simple, low-cost technology. Cool roofs have the potential to quickly and dramatically reduce global carbon emissions while saving money every month on consumers' electrical bills.
Raspberry Pi: a 35-dollar device for viewing DICOM images*
Paiva, Omir Antunes; Moreira, Renata de Oliveira
2014-01-01
Raspberry Pi is a low-cost computer created with educational purposes. It uses Linux and, most of times, freeware applications, particularly a software for viewing DICOM images. With an external monitor, the supported resolution (1920 × 1200 pixels) allows for the set up of simple viewing workstations at a reduced cost. PMID:25741057
Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F
2014-06-01
We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.
A low cost instrumentation system to analyze different types of milk adulteration.
Das, Siuli; Sivaramakrishna, Mulinti; Biswas, Karabi; Goswami, Bhaswati
2015-05-01
In this paper, the design of a complete instrumentation system to detect different types of milk adulteration has been reported. A simple to use indicator type readout device is reported which can be used by milk community people. A low cost microcontroller based automatic sensing system is also reported to detect 'synthetic milk', which has been reconstructed after adulterating the milk with 'liquid-whey'. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
A simple, low-cost conductive composite material for 3D printing of electronic sensors.
Leigh, Simon J; Bradley, Robert J; Purssell, Christopher P; Billson, Duncan R; Hutchins, David A
2012-01-01
3D printing technology can produce complex objects directly from computer aided digital designs. The technology has traditionally been used by large companies to produce fit and form concept prototypes ('rapid prototyping') before production. In recent years however there has been a move to adopt the technology as full-scale manufacturing solution. The advent of low-cost, desktop 3D printers such as the RepRap and Fab@Home has meant a wider user base are now able to have access to desktop manufacturing platforms enabling them to produce highly customised products for personal use and sale. This uptake in usage has been coupled with a demand for printing technology and materials able to print functional elements such as electronic sensors. Here we present formulation of a simple conductive thermoplastic composite we term 'carbomorph' and demonstrate how it can be used in an unmodified low-cost 3D printer to print electronic sensors able to sense mechanical flexing and capacitance changes. We show how this capability can be used to produce custom sensing devices and user interface devices along with printed objects with embedded sensing capability. This advance in low-cost 3D printing with offer a new paradigm in the 3D printing field with printed sensors and electronics embedded inside 3D printed objects in a single build process without requiring complex or expensive materials incorporating additives such as carbon nanotubes.
O’Brien, J. Patrick; Malvankar, Nikhil S.
2017-01-01
Anaerobic microorganisms play a central role in several environmental processes and regulate global biogeochemical cycling of nutrients and minerals. Many anaerobic microorganisms are important for the production of bioenergy and biofuels. However, the major hurdle in studying anaerobic microorganisms in the laboratory is the requirement for sophisticated and expensive gassing stations and glove boxes to create and maintain the anaerobic environment. This appendix presents a simple design for a gassing station that can be used readily by an inexperienced investigator for cultivation of anaerobic microorganisms. In addition, this appendix also details the low-cost assembly of bioelectrochemical systems and outlines a simplified procedure for cultivating and analyzing bacterial cell cultures and biofilms that produce electric current, using Geobacter sulfurreducens as a model organism. PMID:27858972
Reduction of capacity decay in vanadium flow batteries by an electrolyte-reflow method
NASA Astrophysics Data System (ADS)
Wang, Ke; Liu, Le; Xi, Jingyu; Wu, Zenghua; Qiu, Xinping
2017-01-01
Electrolyte imbalance is a major issue with Vanadium flow batteries (VFBs) as it has a significant impact on electrolyte utilization and cycle life over extended charge-discharge cycling. This work seeks to reduce capacity decay and prolong cycle life of VFBs by adopting a novel electrolyte-reflow method. Different current density and various start-up time of the method are investigated in the charge-discharge tests. The results show that the capacity decay rate is reduced markedly and the cycle life is prolonged substantially by this method. In addition, the coulomb efficiency, voltage efficiency and energy efficiency remain stable during the whole cycle life test, which indicates this method has little impact on the long lifetime performance of the VFBs. The method is low-cost, simple, effective, and can be applied in industrial VFB productions.
Lee, Dongil; Yoon, Jinsu; Lee, Juhee; Lee, Byung-Hyun; Seol, Myeong-Lok; Bae, Hagyoul; Jeon, Seung-Bae; Seong, Hyejeong; Im, Sung Gap; Choi, Sung-Jin; Choi, Yang-Kyu
2016-01-01
Printing electronics has become increasingly prominent in the field of electronic engineering because this method is highly efficient at producing flexible, low-cost and large-scale thin-film transistors. However, TFTs are typically constructed with rigid insulating layers consisting of oxides and nitrides that are brittle and require high processing temperatures, which can cause a number of problems when used in printed flexible TFTs. In this study, we address these issues and demonstrate a method of producing inkjet-printed TFTs that include an ultra-thin polymeric dielectric layer produced by initiated chemical vapor deposition (iCVD) at room temperature and highly purified 99.9% semiconducting carbon nanotubes. Our integrated approach enables the production of flexible logic circuits consisting of CNT-TFTs on a polyethersulfone (PES) substrate that have a high mobility (up to 9.76 cm2 V−1 sec−1), a low operating voltage (less than 4 V), a high current on/off ratio (3 × 104), and a total device yield of 90%. Thus, it should be emphasized that this study delineates a guideline for the feasibility of producing flexible CNT-TFT logic circuits with high performance based on a low-cost and simple fabrication process. PMID:27184121
NASA Astrophysics Data System (ADS)
Lee, Dongil; Yoon, Jinsu; Lee, Juhee; Lee, Byung-Hyun; Seol, Myeong-Lok; Bae, Hagyoul; Jeon, Seung-Bae; Seong, Hyejeong; Im, Sung Gap; Choi, Sung-Jin; Choi, Yang-Kyu
2016-05-01
Printing electronics has become increasingly prominent in the field of electronic engineering because this method is highly efficient at producing flexible, low-cost and large-scale thin-film transistors. However, TFTs are typically constructed with rigid insulating layers consisting of oxides and nitrides that are brittle and require high processing temperatures, which can cause a number of problems when used in printed flexible TFTs. In this study, we address these issues and demonstrate a method of producing inkjet-printed TFTs that include an ultra-thin polymeric dielectric layer produced by initiated chemical vapor deposition (iCVD) at room temperature and highly purified 99.9% semiconducting carbon nanotubes. Our integrated approach enables the production of flexible logic circuits consisting of CNT-TFTs on a polyethersulfone (PES) substrate that have a high mobility (up to 9.76 cm2 V-1 sec-1), a low operating voltage (less than 4 V), a high current on/off ratio (3 × 104), and a total device yield of 90%. Thus, it should be emphasized that this study delineates a guideline for the feasibility of producing flexible CNT-TFT logic circuits with high performance based on a low-cost and simple fabrication process.
Concurrent error detecting codes for arithmetic processors
NASA Technical Reports Server (NTRS)
Lim, R. S.
1979-01-01
A method of concurrent error detection for arithmetic processors is described. Low-cost residue codes with check-length l and checkbase m = 2 to the l power - 1 are described for checking arithmetic operations of addition, subtraction, multiplication, division complement, shift, and rotate. Of the three number representations, the signed-magnitude representation is preferred for residue checking. Two methods of residue generation are described: the standard method of using modulo m adders and the method of using a self-testing residue tree. A simple single-bit parity-check code is described for checking the logical operations of XOR, OR, and AND, and also the arithmetic operations of complement, shift, and rotate. For checking complement, shift, and rotate, the single-bit parity-check code is simpler to implement than the residue codes.
Photometric method for determination of acidity constants through integral spectra analysis.
Zevatskiy, Yuriy Eduardovich; Ruzanov, Daniil Olegovich; Samoylov, Denis Vladimirovich
2015-04-15
An express method for determination of acidity constants of organic acids, based on the analysis of the integral transmittance vs. pH dependence is developed. The integral value is registered as a photocurrent of photometric device simultaneously with potentiometric titration. The proposed method allows to obtain pKa using only simple and low-cost instrumentation. The optical part of the experimental setup has been optimized through the exclusion of the monochromator device. Thus it only takes 10-15 min to obtain one pKa value with the absolute error of less than 0.15 pH units. Application limitations and reliability of the method have been tested for a series of organic acids of various nature. Copyright © 2015 Elsevier B.V. All rights reserved.
Chen, Shuming; Kwok, Hoi Sing
2010-01-04
Light extraction from organic light-emitting diodes (OLEDs) by scattering the light is one of the effective methods for large-area lighting applications. In this paper, we present a very simple and cost-effective method to rough the substrates and hence to scatter the light. By simply sand-blasting the edges and back-side surface of the glass substrates, a 20% improvement of forward efficiency has been demonstrated. Moreover, due to scattering effect, a constant color over all viewing angles and uniform light pattern with Lambertian distribution has been obtained. This simple and cost-effective method may be suitable for mass production of large-area OLEDs for lighting applications.
Low cost hydrogen/novel membrane technology for hydrogen separation from synthesis gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1986-02-01
To make the coal-to-hydrogen route economically attractive, improvements are being sought in each step of the process: coal gasification, water-carbon monoxide shift reaction, and hydrogen separation. This report addresses the use of membranes in the hydrogen separation step. The separation of hydrogen from synthesis gas is a major cost element in the manufacture of hydrogen from coal. Separation by membranes is an attractive, new, and still largely unexplored approach to the problem. Membrane processes are inherently simple and efficient and often have lower capital and operating costs than conventional processes. In this report current ad future trends in hydrogen productionmore » and use are first summarized. Methods of producing hydrogen from coal are then discussed, with particular emphasis on the Texaco entrained flow gasifier and on current methods of separating hydrogen from this gas stream. The potential for membrane separations in the process is then examined. In particular, the use of membranes for H{sub 2}/CO{sub 2}, H{sub 2}/CO, and H{sub 2}/N{sub 2} separations is discussed. 43 refs., 14 figs., 6 tabs.« less
NASA Astrophysics Data System (ADS)
Adelifard, Mehdi; Darudi, Hosein
2016-07-01
There is a great interest in the use of graphene sheets in thin film solar cells with low-cost and good-optoelectronic properties. Here, the production of absorbent conductive reduced graphene oxide (RGO) thin films was investigated. RGO thin films were prepared from spray-coated graphene oxide (GO) layers at various substrate temperature followed by a simple hydrazine-reducing method. The structural, morphological, optical, and electrical characterizations of graphene oxide (GO) and RGO thin films were investigated. X-ray diffraction analysis showed a phase shift from GO to RGO due to hydrazine treatment, in agreement with the FTIR spectra of the layers. FESEM images clearly exhibited continuous films resulting from the overlap of graphene nanosheets. The produced low-cost thin films had high absorption coefficient up to 1.0 × 105 cm-1, electrical resistance as low as 0.9 kΩ/sq, and effective optical band gap of about 1.50 eV, close to the optimum value for solar conversion. The conductive absorbent properties of the reduced graphene oxide thin films would be useful to develop photovoltaic cells.
Introducing criteria based audit into Ugandan maternity units.
Weeks, A D; Alia, G; Ononge, S; Mutungi, A; Otolorin, E O; Mirembe, F M
2004-02-01
Maternal mortality in Uganda has remained unchanged at 500/100 000 over the past 10 years despite concerted efforts to improve the standard of maternity care. It is especially difficult to improve standards in rural areas, where there is little money for improvements. Furthermore, staff may be isolated, poorly paid, disempowered, lacking in morale, and have few skills to bring about change. Training programme to introduce criteria based audit into rural Uganda. Makerere University Medical School, Mulago Hospital (large government teaching hospital in Kampala), and Mpigi District (rural area with 10 small health centres around a district hospital). Didactic teaching about criteria based audit followed by practical work in own units, with ongoing support and follow up workshops. Improvements were seen in many standards of care. Staff showed universal enthusiasm for the training; many staff produced simple, cost-free improvements in their standard of care. Teaching of criteria based audit to those providing health care in developing countries can produce low cost improvements in the standards of care. Because the method is simple and can be used to provide improvements even without new funding, it has the potential to produce sustainable and cost effective changes in the standard of health care. Follow up is needed to prevent a waning of enthusiasm with time.
Performance of a small annular turbojet combustor designed for low cost
NASA Technical Reports Server (NTRS)
Fear, J. S.
1972-01-01
Performance investigations were conducted on a combustor utilizing several cost-reducing innovations and designed for use in a low-cost 4448-N thrust turbojet engine for commercial light aircraft. Low-cost features included simple, air-atomizing fuel injectors; combustor liners of perforated sheet; and the use of inexpensive type 304 stainless-steel material. Combustion efficiencies at the cruise and sea-level-takeoff design points were approximately 97 and 98 percent, respectively. The combustor isothermal pressure loss was 6.3 percent at the cruise-condition diffuser inlet Mach number of 0.34. The combustor exit temperature pattern factor was less than 0.24 at both the cruise and sea-level-takeoff design points. The combustor exit average radial temperature profiles at all conditions were in very good agreement with the design profile.
Affordable Launch Services using the Sport Orbit Transfer System
NASA Astrophysics Data System (ADS)
Goldstein, D. J.
2002-01-01
Despite many advances in small satellite technology, a low-cost, reliable method is needed to place spacecraft in their de- sired orbits. AeroAstro has developed the Small Payload ORbit Transfer (SPORTTM) system to provide a flexible low-cost orbit transfer capability, enabling small payloads to use low-cost secondary launch opportunities and still reach their desired final orbits. This capability allows small payloads to effectively use a wider variety of launch opportunities, including nu- merous under-utilized GTO slots. Its use, in conjunction with growing opportunities for secondary launches, enable in- creased access to space using proven technologies and highly reliable launch vehicles such as the Ariane family and the Starsem launcher. SPORT uses a suite of innovative technologies that are packaged in a simple, reliable, modular system. The command, control and data handling of SPORT is provided by the AeroAstro BitsyTM core electronics module. The Bitsy module also provides power regulation for the batteries and optional solar arrays. The primary orbital maneuvering capability is provided by a nitrous oxide monopropellant propulsion system. This system exploits the unique features of nitrous oxide, which in- clude self-pressurization, good performance, and safe handling, to provide a light-weight, low-cost and reliable propulsion capability. When transferring from a higher energy orbit to a lower energy orbit (i.e. GTO to LEO), SPORT uses aerobraking technol- ogy. After using the propulsion system to lower the orbit perigee, the aerobrake gradually slows SPORT via atmospheric drag. After the orbit apogee is reduced to the target level, an apogee burn raises the perigee and ends the aerobraking. At the conclusion of the orbit transfer maneuver, either the aerobrake or SPORT can be shed, as desired by the payload. SPORT uses a simple design for high reliability and a modular architecture for maximum mission flexibility. This paper will discuss the launch system and its application to small satellite launch without increasing risk. It will also discuss relevant issues such as aerobraking operations and radiation issues, as well as existing partnerships and patents for the system.
The impact of Pulpwood Rail Freight Costs on the Minnesota-Wisconsin Pulpwood Market
David C. Lothner
1976-01-01
Transportation costs affect the marketing and utilization of pulpwood. Their impact on the procurement and utilization of pulpwood often prove difficult to measure because deriving an average annual measure of the transportation cost is difficult. This note, by means of a simple index method for measuring regional interstate pulpwood rail freight costs, illustrates...
Cost-effectiveness of surgery in low- and middle-income countries: a systematic review.
Grimes, Caris E; Henry, Jaymie Ang; Maraka, Jane; Mkandawire, Nyengo C; Cotton, Michael
2014-01-01
There is increasing interest in provision of essential surgical care as part of public health policy in low- and middle-income countries (LMIC). Relatively simple interventions have been shown to prevent death and disability. We reviewed the published literature to examine the cost-effectiveness of simple surgical interventions which could be made available at any district hospital, and compared these to standard public health interventions. PubMed and EMBASE were searched using single and combinations of the search terms "disability adjusted life year" (DALY), "quality adjusted life year," "cost-effectiveness," and "surgery." Articles were included if they detailed the cost-effectiveness of a surgical intervention of relevance to a LMIC, which could be made available at any district hospital. Suitable articles with both cost and effectiveness data were identified and, where possible, data were extrapolated to enable comparison across studies. Twenty-seven articles met our inclusion criteria, representing 64 LMIC over 16 years of study. Interventions that were found to be cost-effective included cataract surgery (cost/DALY averted range US$5.06-$106.00), elective inguinal hernia repair (cost/DALY averted range US$12.88-$78.18), male circumcision (cost/DALY averted range US$7.38-$319.29), emergency cesarean section (cost/DALY averted range US$18-$3,462.00), and cleft lip and palate repair (cost/DALY averted range US$15.44-$96.04). A small district hospital with basic surgical services was also found to be highly cost-effective (cost/DALY averted 1 US$0.93), as were larger hospitals offering emergency and trauma surgery (cost/DALY averted US$32.78-$223.00). This compares favorably with other standard public health interventions, such as oral rehydration therapy (US$1,062.00), vitamin A supplementation (US$6.00-$12.00), breast feeding promotion (US$930.00), and highly active anti-retroviral therapy for HIV (US$922.00). Simple surgical interventions that are life-saving and disability-preventing should be considered as part of public health policy in LMIC. We recommend an investment in surgical care and its integration with other public health measures at the district hospital level, rather than investment in single disease strategies.
A Low-Cost Precision Colorimeter.
ERIC Educational Resources Information Center
Jaffar, M.; Zahid, Qazi
1988-01-01
Presents the construction aspects of a simple but reliable colorimeter made from locally available components. Notes the absorption range to be 400-750-nm. Lists seven experiments done on the instrument. (MVL)
NASA Astrophysics Data System (ADS)
Ye, Xiaosheng; Shi, Hui; He, Xiaoxiao; Yu, Yanru; He, Dinggeng; Tang, Jinlu; Lei, Yanli; Wang, Kemin
2016-01-01
As a star material in cancer theranostics, photoresponsive gold (Au) nanostructures may still have drawbacks, such as low thermal conductivity, irradiation-induced melting effect and high cost. To solve the problem, copper (Cu) with a much higher thermal conductivity and lower cost was introduced to generate a novel Cu-Au alloy nanostructure produced by a simple, gentle and one-pot synthetic method. Having the good qualities of both Cu and Au, the irregularly-shaped Cu-Au alloy nanostructures showed several advantages over traditional Au nanorods, including a broad and intense near-infrared (NIR) absorption band from 400 to 1100 nm, an excellent heating performance under laser irradiation at different wavelengths and even a notable photostability against melting. Then, via a simple conjugation of fluorophore-labeled aptamers on the Cu-Au alloy nanostructures, active targeting and signal output were simultaneously introduced, thus constructing a theranostic platform based on fluorophore-labeled, aptamer-coated Cu-Au alloy nanostructures. By using human leukemia CCRF-CEM cancer and Cy5-labeled aptamer Sgc8c (Cy5-Sgc8c) as the model, a selective fluorescence imaging and NIR photothermal therapy was successfully realized for both in vitro cancer cells and in vivo tumor tissues. It was revealed that Cy5-Sgc8c-coated Cu-Au alloy nanostructures were not only capable of robust target recognition and stable signal output for molecular imaging in complex biological systems, but also killed target cancer cells in mice with only five minutes of 980 nm irradiation. The platform was found to be simple, stable, biocompatible and highly effective, and shows great potential as a versatile tool for cancer theranostics.As a star material in cancer theranostics, photoresponsive gold (Au) nanostructures may still have drawbacks, such as low thermal conductivity, irradiation-induced melting effect and high cost. To solve the problem, copper (Cu) with a much higher thermal conductivity and lower cost was introduced to generate a novel Cu-Au alloy nanostructure produced by a simple, gentle and one-pot synthetic method. Having the good qualities of both Cu and Au, the irregularly-shaped Cu-Au alloy nanostructures showed several advantages over traditional Au nanorods, including a broad and intense near-infrared (NIR) absorption band from 400 to 1100 nm, an excellent heating performance under laser irradiation at different wavelengths and even a notable photostability against melting. Then, via a simple conjugation of fluorophore-labeled aptamers on the Cu-Au alloy nanostructures, active targeting and signal output were simultaneously introduced, thus constructing a theranostic platform based on fluorophore-labeled, aptamer-coated Cu-Au alloy nanostructures. By using human leukemia CCRF-CEM cancer and Cy5-labeled aptamer Sgc8c (Cy5-Sgc8c) as the model, a selective fluorescence imaging and NIR photothermal therapy was successfully realized for both in vitro cancer cells and in vivo tumor tissues. It was revealed that Cy5-Sgc8c-coated Cu-Au alloy nanostructures were not only capable of robust target recognition and stable signal output for molecular imaging in complex biological systems, but also killed target cancer cells in mice with only five minutes of 980 nm irradiation. The platform was found to be simple, stable, biocompatible and highly effective, and shows great potential as a versatile tool for cancer theranostics. Electronic supplementary information (ESI) available: Fig. S1, S2 and Table S1. See DOI: 10.1039/c5nr07017a
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays.
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-19
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Clair J.
The use of radiation detectors as an element in the so-called “Internet of Things” has recently become viable with the available of low-cost, mobile radiation sensors capable of streaming geo-referenced data. New methods for fusing the data from multiple sensors on such a network is presented. The traditional simple and ordinary Kriging methods present a challenge for such a network since the assumption of a constant mean is not valid in this application. In conclusion, a variety of Kalman filters are introduced in an attempt to solve the problem associated with this variable and unknown mean. Results are presented onmore » a deployed sensor network.« less
Sullivan, Clair J.
2016-01-01
The use of radiation detectors as an element in the so-called “Internet of Things” has recently become viable with the available of low-cost, mobile radiation sensors capable of streaming geo-referenced data. New methods for fusing the data from multiple sensors on such a network is presented. The traditional simple and ordinary Kriging methods present a challenge for such a network since the assumption of a constant mean is not valid in this application. In conclusion, a variety of Kalman filters are introduced in an attempt to solve the problem associated with this variable and unknown mean. Results are presented onmore » a deployed sensor network.« less
Development of a Terbium-Sensitized Fluorescence Method for Analysis of Silibinin.
Ershadi, Saba; Jouyban, Abolghasem; Molavi, Ommoleila; Shayanfar, Ali
2017-05-01
Silibinin is a natural flavonoid with potent anticancer properties, as shown in both in vitro and in vivo experiments. Various methods have been used for silibinin analysis. Terbium-sensitized fluorescence methods have been widely used for the determination of drugs in pharmaceutical preparations and biological samples in recent years. The present work is aimed at providing a simple analytical method for the quantitative determination of silibinin in aqueous solutions based on the formation of a fluorescent complex with terbium ion. Terbium concentration, pH, and volume of buffer, the important effective parameters for the determination of silibinin by the proposed method, were optimized using response surface methodology. The fluorescence intensity of silibinin was measured at 545 nm using λex = 334 nm. The developed method was applied for the determination of silibinin in plasma samples after protein precipitation with acetone. Under optimum conditions, the method provided a linear range between 0.10 and 0.50 mg/L, with a coefficient of determination (R2) of 0.997. The LOD and LOQ were 0.034 and 0.112 mg/L, respectively. These results indicate that the developed method is a simple, low-cost, and suitable analytical method for the quantification of silibinin in aqueous solution and plasma samples.
2013-01-01
We demonstrated a novel, simple, and low-cost method to fabricate silicon nanowire (SiNW) arrays and silicon nanohole (SiNH) arrays based on thin silver (Ag) film dewetting process combined with metal-assisted chemical etching. Ag mesh with holes and semispherical Ag nanoparticles can be prepared by simple thermal annealing of Ag thin film on a silicon substrate. Both the diameter and the distribution of mesh holes as well as the nanoparticles can be manipulated by the film thickness and the annealing temperature. The silicon underneath Ag coverage was etched off with the catalysis of metal in an aqueous solution containing HF and an oxidant, which form silicon nanostructures (either SiNW or SiNH arrays). The morphologies of the corresponding etched SiNW and SiNH arrays matched well with that of Ag holes and nanoparticles. This novel method allows lithography-free fabrication of the SiNW and SiNH arrays with control of the size and distribution. PMID:23557325
Increasing the realism of a laparoscopic box trainer: a simple, inexpensive method.
Hull, Louise; Kassab, Eva; Arora, Sonal; Kneebone, Roger
2010-01-01
Simulation-based training in medical education is increasing. Realism is an integral element of creating an engaging, effective training environment. Although physical trainers offer a low-cost alternative to expensive virtual reality (VR) simulators, many lack in realism. The aim of this research was to enhance the realism of a laparoscopic box trainer by using a simple, inexpensive method. Digital images of the abdominal cavity were captured from a VR simulator. The images were printed onto a laminated card that lined the bottom and sides of the box-trainer cavity. The standard black neoprene material that encloses the abdominal cavity was replaced with a skin-colored silicon model. The realism of the modified box trainer was assessed by surgeons, using quantitative and qualitative methodologies. Results suggest that the modified box trainer was more realistic than a standard box trainer alone. Incorporating this technique in the training of laparoscopic skills is an inexpensive means of emulating surgical reality that may enhance the engagement of the learner in simulation.
Audio Classification in Speech and Music: A Comparison between a Statistical and a Neural Approach
NASA Astrophysics Data System (ADS)
Bugatti, Alessandro; Flammini, Alessandra; Migliorati, Pierangelo
2002-12-01
We focus the attention on the problem of audio classification in speech and music for multimedia applications. In particular, we present a comparison between two different techniques for speech/music discrimination. The first method is based on Zero crossing rate and Bayesian classification. It is very simple from a computational point of view, and gives good results in case of pure music or speech. The simulation results show that some performance degradation arises when the music segment contains also some speech superimposed on music, or strong rhythmic components. To overcome these problems, we propose a second method, that uses more features, and is based on neural networks (specifically a multi-layer Perceptron). In this case we obtain better performance, at the expense of a limited growth in the computational complexity. In practice, the proposed neural network is simple to be implemented if a suitable polynomial is used as the activation function, and a real-time implementation is possible even if low-cost embedded systems are used.
Scalable graphene production from ethanol decomposition by microwave argon plasma torch
NASA Astrophysics Data System (ADS)
Melero, C.; Rincón, R.; Muñoz, J.; Zhang, G.; Sun, S.; Perez, A.; Royuela, O.; González-Gago, C.; Calzada, M. D.
2018-01-01
A fast, efficient and simple method is presented for the production of high quality graphene on a large scale by using an atmospheric pressure plasma-based technique. This technique allows to obtain high quality graphene in powder in just one step, without the use of neither metal catalysts and nor specific substrate during the process. Moreover, the cost for graphene production is significantly reduced since the ethanol used as carbon source can be obtained from the fermentation of agricultural industries. The process provides an additional benefit contributing to the revalorization of waste in the production of a high-value added product like graphene. Thus, this work demonstrates the features of plasma technology as a low cost, efficient, clean and environmentally friendly route for production of high-quality graphene.
RTD fluxgate performance for application in magnetic label-based bioassay: preliminary results.
Ando, B; Ascia, A; Baglio, S; Bulsara, A R; Trigona, C; In, V
2006-01-01
Magnetic bioassay is becoming of great interest in several application including magnetic separation, drug delivery, hyperthermia treatments, magnetic resonance imaging (MRI) and magnetic labelling. The latter can be used to localize bio-entities (e.g. cancer tissues) by using magnetic markers and high sensitive detectors. To this aim SQUIDs can be adopted, however this result in a quite sophisticated and complex method involving high cost and complex set-up. In this paper, the possibility to adopt RTD fluxgate magnetometers as alternative low cost solution to perform magnetic bio-sensing is investigated. Some experimental results are shown that encourage to pursue this approach in order to obtain simple devices that can detect a certain number of magnetic particles accumulated onto a small surface such to be useful for diagnosis purposes.
NASA Astrophysics Data System (ADS)
Mutta, Geeta R.; Popuri, Srinivasa R.; Wilson, John I. B.; Bennett, Nick S.
2016-11-01
In this work, we aim to develop a viable, inexpensive and non-toxic material for counter electrodes in dye sensitized solar cells (DSSCs). We employed an ultra-simple synthesis process to deposit MoO3 thin films at low temperature by sol-gel spin coating technique. These MoO3 films showed good transparency. It is predicted that there will be 150 times reduction of precursors cost by realizing MoO3 thin films as a counter electrode in DSSCs compared to commercial Pt. We achieved a device efficiency of about 20 times higher than that of the previous reported values. In summary we develop a simple low cost preparation of MoO3 films with an easily scaled up process along with good device efficiency. This work encourages the development of novel and relatively new materials and paves the way for massive reduction of industrial costs which is a prime step for commercialization of DSSCs.
Gurdita, Akshay; Vovko, Heather; Ungrin, Mark
2016-01-01
Basic equipment such as incubation and refrigeration systems plays a critical role in nearly all aspects of the traditional biological research laboratory. Their proper functioning is therefore essential to ensure reliable and repeatable experimental results. Despite this fact, in many academic laboratories little attention is paid to validating and monitoring their function, primarily due to the cost and/or technical complexity of available commercial solutions. We have therefore developed a simple and low-cost monitoring system that combines a "Raspberry Pi" single-board computer with USB-connected sensor interfaces to track and log parameters such as temperature and pressure, and send email alert messages as appropriate. The system is controlled by open-source software, and we have also generated scripts to automate software setup so that no background in programming is required to install and use it. We have applied it to investigate the behaviour of our own equipment, and present here the results along with the details of the monitoring system used to obtain them.
Miretzky, P; Cirelli, A Fernandez
2010-08-15
In aqueous systems, chromium usually exists in both trivalent and hexavalent oxidation states, being Cr(VI) of particular importance and concern due to its great toxicity. Industrial sources of Cr(VI) are leather tanning, mining of chrome ore, production of steel and alloys, etc. The most common conventional method for Cr(VI) removal is reduction to Cr(III) at pH 2.0 and precipitation of Cr (OH)(3) with lime at pH 9-10. The disadvantage of precipitation is the disposal of the solid waste. Adsorption of Cr by different low cost materials seems to be a suitable choice for wastewater treatment. Many by-products of agriculture have proved to be suitable low cost adsorbents for Cr(VI) and Cr(III) removal from water. Lignocellulosic residues, which include both wood residues and agricultural residues, have adsorption capacity comparable to other natural sorbents, but they have the advantage of very low or no cost, great availability and simple operational process. This study is a review of the recent literature on the use of natural and modified lignocellulosic residues for Cr adsorption. The Cr maximum adsorption capacity and the adsorption mechanism under different experimental conditions are reported when possibly. Copyright 2010 Elsevier B.V. All rights reserved.
A convenient Simple Method for Synthesis of Meta-iodobenzylguanidine (MIBG).
Sheikholislam, Zahra; Soleimani, Zohreh; Moghimi, Abolghasem; Shahhosseini, Soraya
2013-01-01
Radioiodinated meta-iodobenzylguanidine (MIBG) is one of the important radiopharmaceuticals in Nuclear Medicine. [(123/131)I] MIBG is used for imaging of Adrenal medulla, studying heart sympathetic nerves, treatment of pheochromacytoma and neuroblastoma. For clinical application, radioiodinated MIBG is prepared through isotopic exchange method, which includes replacement of radioactive iodine in a nucleophilic substitution reaction with cold iodine ((127)I). The unlabelled MIBG hemisulfate is synthesized by the procedure described by Wieland et al. (1980). The availability of a more practical and cost-effective procedure for MIBG preparation encouraged us to study the MIBG synthesis methods. In this study the preparation of MIBG through different methods were evaluated and a new method, which is one step, simple and cost-effective is introduced. The method has ability to be scaled up for production of unlabelled MIBG.
Implementation and Testing of Low Cost Uav Platform for Orthophoto Imaging
NASA Astrophysics Data System (ADS)
Brucas, D.; Suziedelyte-Visockiene, J.; Ragauskas, U.; Berteska, E.; Rudinskas, D.
2013-08-01
Implementation of Unmanned Aerial Vehicles for civilian applications is rapidly increasing. Technologies which were expensive and available only for military use have recently spread on civilian market. There is a vast number of low cost open source components and systems for implementation on UAVs available. Using of low cost hobby and open source components ensures considerable decrease of UAV price, though in some cases compromising its reliability. In Space Science and Technology Institute (SSTI) in collaboration with Vilnius Gediminas Technical University (VGTU) researches have been performed in field of constructing and implementation of small UAVs composed of low cost open source components (and own developments). Most obvious and simple implementation of such UAVs - orthophoto imaging with data download and processing after the flight. The construction, implementation of UAVs, flight experience, data processing and data implementation will be further covered in the paper and presentation.
A DSMC Study of Low Pressure Argon Discharge
NASA Astrophysics Data System (ADS)
Hash, David; Meyyappan, M.
1997-10-01
Work toward a self-consistent plasma simulation using the DSMC method for examination of the flowfields of low-pressure high density plasma reactors is presented. Presently, DSMC simulations for these applications involve either treating the electrons as a fluid or imposing experimentally determined values for the electron number density profile. In either approach, the electrons themselves are not physically simulated. Self-consistent plasma DSMC simulations have been conducted for aerospace applications but at a severe computational cost due in part to the scalar architectures on which the codes were employed. The present work attempts to conduct such simulations at a more reasonable cost using a plasma version of the object-oriented parallel Cornell DSMC code, MONACO, on an IBM SP-2. Due the availability of experimental data, the GEC reference cell is chosen to conduct preliminary investigations. An argon discharge is examined thus affording a simple chemistry set with eight gas-phase reactions and five species: Ar, Ar^+, Ar^*, Ar_2, and e where Ar^* is a metastable.
A simple cost-effective design for construction of a laparoscopic trainer.
Ricchiuti, Daniel; Ralat, Dane Arends; Evancho-Chapman, Michelle; Wyneski, Holly; Cerone, Jeffrey; Wegryn, John D
2005-10-01
Laparoscopic trainers have been shown to be effective tools for transitioning residents in surgical fields into live laparoscopic techniques. There have been few reports of homemade trainers, but each of these reports provides only scant detail about their construction, making production a novel task to those interested in employing this equipment. Virtual-reality trainers are gaining popularity and are exceptional modalities in the re-creation of laparoscopic surgery. In their present state, however, such trainers are very costly, making them unattainable by most urology residency programs. Numerous commercial non-virtual trainers are also available; however, these trainers are often cost-prohibitive or overly simplistic. We describe a detailed design template for creation of a laparoscopic trainer based on modifications of previous designs. This trainer can be made easily at a cost of approximately US$275.00 and may be used in conjunction with existing laparoscopic equipment. The methods described herein can be followed by any local machinist to create this trainer. The relatively low total cost, ready material availability, and ease of construction make this trainer an appropriate option for the training of residents in laparoscopic procedures.
Cai, Wei; Zhu, Zhennan; Wei, Jinglin; Fang, Zhiqiang; Zheng, Zeke; Zhou, Shangxiong; Peng, Junbiao; Lu, Xubing
2017-01-01
Solution-processed high-k dielectric TFTs attract much attention since they cost relatively little and have a simple fabrication process. However, it is still a challenge to reduce the leakage of the current density of solution-processed dielectric TFTs. Here, a simple solution method is presented towards enhanced performance of ZrO2 films by intentionally increasing the concentration of precursor. The ZrO2 films not only exhibit a low leakage current density of 10−6 A/cm2 at 10 V and a breakdown field of 2.5 MV/cm, but also demonstrate a saturation mobility of 12.6 cm2·V−1·s−1 and a Ion/Ioff ratio of 106 in DC pulse sputtering IGZO-TFTs based on these films. Moreover, the underlying mechanism of influence of precursor concentration on film formation is presented. Higher concentration precursor results in a thicker film within same coating times with reduced ZrO2/IGZO interface defects and roughness. It shows the importance of thickness, roughness, and annealing temperature in solution-processed dielectric oxide TFT and provides an approach to precisely control solution-processed oxide films thickness. PMID:28825652
Cai, Wei; Zhu, Zhennan; Wei, Jinglin; Fang, Zhiqiang; Ning, Honglong; Zheng, Zeke; Zhou, Shangxiong; Yao, Rihui; Peng, Junbiao; Lu, Xubing
2017-08-21
Solution-processed high-k dielectric TFTs attract much attention since they cost relatively little and have a simple fabrication process. However, it is still a challenge to reduce the leakage of the current density of solution-processed dielectric TFTs. Here, a simple solution method is presented towards enhanced performance of ZrO₂ films by intentionally increasing the concentration of precursor. The ZrO₂ films not only exhibit a low leakage current density of 10 -6 A/cm² at 10 V and a breakdown field of 2.5 MV/cm, but also demonstrate a saturation mobility of 12.6 cm²·V -1 ·s -1 and a I on /I off ratio of 10⁶ in DC pulse sputtering IGZO-TFTs based on these films. Moreover, the underlying mechanism of influence of precursor concentration on film formation is presented. Higher concentration precursor results in a thicker film within same coating times with reduced ZrO₂/IGZO interface defects and roughness. It shows the importance of thickness, roughness, and annealing temperature in solution-processed dielectric oxide TFT and provides an approach to precisely control solution-processed oxide films thickness.
Course Keeping Control of an Autonomous Boat using Low Cost Sensors
NASA Astrophysics Data System (ADS)
Yu, Zhenyu; Bao, Xinping; Nonami, Kenzo
This paper discusses the course keeping control problem for a small autonomous boat using low cost sensors. Comparing with full scale ships, a small boat is more sensitive to the environmental disturbances because of its small size and low inertia. The sensors available in the boat are a low cost GPS and a rate gyro while the commonly used compass in ship control is absent. The combined effect from disturbance, poor accuracy and significant delay in GPS measurement makes it a challenging task to achieve good performance. In this paper, we propose a simple dynamic model for the boat's horizontal motion. The model is based on the Nomoto's model and can be seen as an extension to it. The model describes the dynamics between rudder deflection and the boat's velocity vector angle while Nomoto's model reveals that between rudder deflection and the boat's yaw angle. With the proposed model there is no need for a yaw sensor for control if the boat's moving direction can be measured. GPS is a convenient device for that job. Based on the derived model, we apply mixed H2/H∞ control method to design the controller. It can guarantee the robust stability, and as the same time it can optimize the performance in the sense of H2 norm. The experimental data show that the proposed approach is proved to be effective and useful.
Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz
2015-01-01
In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.
A simple, low-cost, versatile CCD spectrometer for plasma spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Den Hartog, D. J.; Holly, D. J.
1996-06-01
The authors have constructed a simple, low-cost CCD spectrometer capable of both high resolution ({Delta}{lambda} {le} 0.015 nm) and large bandpass (110 nm with {Delta}{lambda} {approximately}0.3 nm). These two modes of operation provide two broad areas of capability for plasma spectroscopy. The first major application is measurement of emission line broadening; the second is emission line surveys from the ultraviolet to the near infrared. Measurements have been made on a low-temperature plasma produced by a miniature electrostatic plasma source and the high-temperature plasma in the MST Reversed-Field Pinch. The spectrometer is a modified Jarrell-Ash 0.5 m Ebert-Fastie monochromator. Light ismore » coupled into the entrance slit with a fused silica fiber optic bundle. The exposure time (2 ms minimum) is controlled by a fast electromechanical shutter. The exit plane detector is a compact and robust CCD detector developed for amateur astronomy by Santa Barbara Instrument Group. The CCD detector is controlled and read out by a Macintosh{reg_sign} computer. This spectrometer is sophisticated enough to serve well in a research laboratory, yet is simple and inexpensive enough to be affordable for instructional use.« less
Odometers for Rail Application
DOT National Transportation Integrated Search
1975-05-01
Available mileage counters were evaluated, anticipating the possibility of using mileage intervals, rather than elapsed time, for freight car inspection. Simple, reliable and reasonably low costing devices were required. Only two unpowered mileage co...
ERIC Educational Resources Information Center
Hosker, Bill S.
2018-01-01
A highly simplified variation on the do-it-yourself spectrophotometer using a smartphone's light sensor as a detector and an app to calculate and display absorbance values was constructed and tested. This simple version requires no need for electronic components or postmeasurement spectral analysis. Calibration graphs constructed from two…
A Simple Demonstration for Exploring the Radio Waves Generated by a Mobile Phone
ERIC Educational Resources Information Center
Hare, Jonathan
2010-01-01
Described is a simple low cost home-made device that converts the radio wave energy from a mobile phone signal into electricity for lighting an LED. No battery or complex circuitry is required. The device can form the basis of a range of interesting experiments on the physics and technology of mobile phones. (Contains 5 figures.)
Construction of a Simple Low-Cost Teslameter and Its Use with Arduino and MakerPlot Software
ERIC Educational Resources Information Center
Atkin, Keith
2016-01-01
This paper shows how it is possible to construct a very simple device for the measurement of magnetic flux densities in an educational context. It is also shown how such a device can be interfaced to a microcontroller with plotting-software to facilitate the study of magnetic fields produced by a current-carrying coil.
NASA Astrophysics Data System (ADS)
Sánchez, H. R.; Pis Diez, R.
2016-04-01
Based on the Aλ diagnostic for multireference effects recently proposed [U.R. Fogueri, S. Kozuch, A. Karton, J.M. Martin, Theor. Chem. Acc. 132 (2013) 1], a simple method for improving total atomization energies and reaction energies calculated at the CCSD level of theory is proposed. The method requires a CCSD calculation and two additional density functional theory calculations for the molecule. Two sets containing 139 and 51 molecules are used as training and validation sets, respectively, for total atomization energies. An appreciable decrease in the mean absolute error from 7-10 kcal mol-1 for CCSD to about 2 kcal mol-1 for the present method is observed. The present method provides atomization energies and reaction energies that compare favorably with relatively recent scaled CCSD methods.
Investigation of self-adaptive LED surgical lighting based on entropy contrast enhancing method
NASA Astrophysics Data System (ADS)
Liu, Peng; Wang, Huihui; Zhang, Yaqin; Shen, Junfei; Wu, Rengmao; Zheng, Zhenrong; Li, Haifeng; Liu, Xu
2014-05-01
Investigation was performed to explore the possibility of enhancing contrast by varying the spectral distribution (SPD) of the surgical lighting. The illumination scenes with different SPDs were generated by the combination of a self-adaptive white light optimization method and the LED ceiling system, the images of biological sample are taken by a CCD camera and then processed by an 'Entropy' based contrast evaluation model which is proposed specific for surgery occasion. Compared with the neutral white LED based and traditional algorithm based image enhancing methods, the illumination based enhancing method turns out a better performance in contrast enhancing and improves the average contrast value about 9% and 6%, respectively. This low cost method is simple, practicable, and thus may provide an alternative solution for the expensive visual facility medical instruments.
Multiplexed microsatellite recovery using massively parallel sequencing
Jennings, T.N.; Knaus, B.J.; Mullins, T.D.; Haig, S.M.; Cronn, R.C.
2011-01-01
Conservation and management of natural populations requires accurate and inexpensive genotyping methods. Traditional microsatellite, or simple sequence repeat (SSR), marker analysis remains a popular genotyping method because of the comparatively low cost of marker development, ease of analysis and high power of genotype discrimination. With the availability of massively parallel sequencing (MPS), it is now possible to sequence microsatellite-enriched genomic libraries in multiplex pools. To test this approach, we prepared seven microsatellite-enriched, barcoded genomic libraries from diverse taxa (two conifer trees, five birds) and sequenced these on one lane of the Illumina Genome Analyzer using paired-end 80-bp reads. In this experiment, we screened 6.1 million sequences and identified 356958 unique microreads that contained di- or trinucleotide microsatellites. Examination of four species shows that our conversion rate from raw sequences to polymorphic markers compares favourably to Sanger- and 454-based methods. The advantage of multiplexed MPS is that the staggering capacity of modern microread sequencing is spread across many libraries; this reduces sample preparation and sequencing costs to less than $400 (USD) per species. This price is sufficiently low that microsatellite libraries could be prepared and sequenced for all 1373 organisms listed as 'threatened' and 'endangered' in the United States for under $0.5M (USD).
A unique modulation system for two channel data transmission
NASA Technical Reports Server (NTRS)
Melrose, B. T.
1972-01-01
A simple low cost system is reported for the telemetry of information from meteorological rocket payloads including parachute borne systems. It uses S- or L-band microwave links with low cost oscillator type transmitters. An extension of this system to transmit two channels of data simultaneously by standard time and frequency multiplexing techniques as a sampled pulse is described. One channel is represented by the pulse repetition rate while the other channel is represented by the instantaneous duty cycle of the pulse train.
Low Cost Mars Surface Exploration: The Mars Tumbleweed
NASA Technical Reports Server (NTRS)
Antol, Jeffrey; Calhoun, Philip; Flick, John; Hajos, Gregory; Kolacinski, Richard; Minton, David; Owens, Rachel; Parker, Jennifer
2003-01-01
The "Mars Tumbleweed," a rover concept that would utilize surface winds for mobility, is being examined as a low cost complement to the current Mars exploration efforts. Tumbleweeds carrying microinstruments would be driven across the Martian landscape by wind, searching for areas of scientific interest. These rovers, relatively simple, inexpensive, and deployed in large numbers to maximize coverage of the Martian surface, would provide a broad scouting capability to identify specific sites for exploration by more complex rover and lander missions.
2008-09-01
Explosives have been detected in HGR soils at levels from the low parts per billion (µg/kg) up to percent levels. RDX has been detected in leachate waters...soil are transport in surface water and subsurface transport in leachate . Simple, innovative, and cost effective technologies are being developed which...range via surface water and leachate . This technology demonstrated that application of lime is a low-cost treatment that can be incorporated into
High-throughput purification of recombinant proteins using self-cleaving intein tags.
Coolbaugh, M J; Shakalli Tang, M J; Wood, D W
2017-01-01
High throughput methods for recombinant protein production using E. coli typically involve the use of affinity tags for simple purification of the protein of interest. One drawback of these techniques is the occasional need for tag removal before study, which can be hard to predict. In this work, we demonstrate two high throughput purification methods for untagged protein targets based on simple and cost-effective self-cleaving intein tags. Two model proteins, E. coli beta-galactosidase (βGal) and superfolder green fluorescent protein (sfGFP), were purified using self-cleaving versions of the conventional chitin-binding domain (CBD) affinity tag and the nonchromatographic elastin-like-polypeptide (ELP) precipitation tag in a 96-well filter plate format. Initial tests with shake flask cultures confirmed that the intein purification scheme could be scaled down, with >90% pure product generated in a single step using both methods. The scheme was then validated in a high throughput expression platform using 24-well plate cultures followed by purification in 96-well plates. For both tags and with both target proteins, the purified product was consistently obtained in a single-step, with low well-to-well and plate-to-plate variability. This simple method thus allows the reproducible production of highly pure untagged recombinant proteins in a convenient microtiter plate format. Copyright © 2016 Elsevier Inc. All rights reserved.
Laboratory Connections--Gas Monitoring Transducers Part III: Combustible Gas Sensors.
ERIC Educational Resources Information Center
Powers, Michael H.; Dahman, Doug
1989-01-01
Describes an interface that uses semiconductor metal oxides to detect low gas concentrations. Notes the detector has long life, high stability, good reproducibility, low cost, and is able to convert the gas concentration to an electrical signal with a simple circuit. Theory, schematic, and applications are provided. (MVL)
A flexible, low-cost cart for proximal sensing
USDA-ARS?s Scientific Manuscript database
Agricultural researchers increasingly use diverse types of electronic sensors to monitor how crops grow and respond to problems such as drought and low soil fertility. In order to take measurements on large numbers of plots in an experiment, there is a need to for simple, high-clearance vehicles tha...
Sanjay, Sharma T; Dou, Maowei; Sun, Jianjun; Li, XiuJun
2016-07-26
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.
Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, XiuJun
2016-01-01
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings. PMID:27456979
NASA Astrophysics Data System (ADS)
Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, Xiujun
2016-07-01
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.
Semi-automatic characterization and simulation of VCSEL devices for high speed VSR communications
NASA Astrophysics Data System (ADS)
Pellevrault, S.; Toffano, Z.; Destrez, A.; Pez, M.; Quentel, F.
2006-04-01
Very short range (VSR) high bit rate optical fiber communications are an emerging market dedicated to local area networks, digital displays or board to board interconnects within real time calculators. In this technology, a very fast way to exchange data with high noise immunity and low-cost is needed. Optical multimode graded index fibers are used here because they have electrical noise immunity and are easier to handle than monomode fibers. 850 nm VCSEL are used in VSR communications because of their low cost, direct on-wafer tests, and the possibility of manufacturing VCSEL arrays very easily compared to classical optical transceivers using edge-emitting laser diodes. Although much research has been carried out in temperature modeling on VCSEL emitters, few studies have been devoted to characterizations over a very broad range of temperatures. Nowadays, VCSEL VSR communications tend to be used in severe environments such as space, avionics and military equipments. Therefore, a simple way to characterize VCSEL emitters over a broad range of temperature is required. In this paper, we propose a complete characterization of the emitter part of 2.5 Gb/s opto-electrical transceiver modules operating from -40°C to +120°C using 850 nm VCSELs. Our method uses simple and semi-automatic measurements of a given set of chosen device parameters in order to make fast and efficient simulations.
Measurement of luminescence decays: High performance at low cost
NASA Astrophysics Data System (ADS)
Sulkes, Mark; Sulkes, Zoe
2011-11-01
The availability of inexpensive ultra bright LEDs spanning the visible and near-ultraviolet combined with the availability of inexpensive electronics equipment makes it possible to construct a high performance luminescence lifetime apparatus (˜5 ns instrumental response or better) at low cost. A central need for time domain measurement systems is the ability to obtain short (˜1 ns or less) excitation light pulses from the LEDs. It is possible to build the necessary LED driver using a simple avalanche transistor circuit. We describe first a circuit to test for small signal NPN transistors that can avalanche. We then describe a final optimized avalanche mode circuit that we developed on a prototyping board by measuring driven light pulse duration as a function of the circuit on the board and passive component values. We demonstrate that the combination of the LED pulser and a 1P28 photomultiplier tube used in decay waveform acquisition has a time response that allows for detection and lifetime determination of luminescence decays down to ˜5 ns. The time response and data quality afforded with the same components in time-correlated single photon counting are even better. For time-correlated single photon counting an even simpler NAND-gate based LED driver circuit is also applicable. We also demonstrate the possible utility of a simple frequency domain method for luminescence lifetime determinations.
Urban Land Cover Mapping Accuracy Assessment - A Cost-benefit Analysis Approach
NASA Astrophysics Data System (ADS)
Xiao, T.
2012-12-01
One of the most important components in urban land cover mapping is mapping accuracy assessment. Many statistical models have been developed to help design simple schemes based on both accuracy and confidence levels. It is intuitive that an increased number of samples increases the accuracy as well as the cost of an assessment. Understanding cost and sampling size is crucial in implementing efficient and effective of field data collection. Few studies have included a cost calculation component as part of the assessment. In this study, a cost-benefit sampling analysis model was created by combining sample size design and sampling cost calculation. The sampling cost included transportation cost, field data collection cost, and laboratory data analysis cost. Simple Random Sampling (SRS) and Modified Systematic Sampling (MSS) methods were used to design sample locations and to extract land cover data in ArcGIS. High resolution land cover data layers of Denver, CO and Sacramento, CA, street networks, and parcel GIS data layers were used in this study to test and verify the model. The relationship between the cost and accuracy was used to determine the effectiveness of each sample method. The results of this study can be applied to other environmental studies that require spatial sampling.
Pristine carbon nanotubes based resistive temperature sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alam, Md Bayazeed, E-mail: bayazeed786@gmail.com; Jamia Millia Islamia; Saini, Sudhir Kumar, E-mail: sudhirsaini1310@gmail.com
A good sensor must be highly sensitive, faster in response, of low cost cum easily producible, and highly reliable. Incorporation of nano-dimensional particles/ wires makes conventional sensors more effective in terms of fulfilling the above requirements. For example, Carbon Nanotubes (CNTs) are promising sensing element because of its large aspect ratio, unique electronic and thermal properties. In addition to their use for widely reported chemical sensing, it has also been explored for temperature sensing. This paper presents the fabrication of CNTs based temperature sensor, prepared on silicon substrate using low cost spray coating method, which is reliable and reproducible methodmore » to prepare uniform CNTs thin films on any substrate. Besides this, simple and inexpensive method of preparation of dispersion of single walled CNTs (SWNTs) in 1,2 dichlorobenzene by using probe type ultrasonicator for debundling the CNTs for improving sensor response were used. The electrical contacts over the dispersed SWNTs were taken using silver paste electrodes. Fabricated sensors clearly show immediate change in resistance as a response to change in temperature of SWNTs. The measured sensitivity (change in resistance with temperature) of the sensor was found ∼ 0.29%/°C in the 25°C to 60°C temperature range.« less
Nema, Shubham; Hasan, Whidul; Bhargava, Anamika; Bhargava, Yogesh
2016-09-15
Behavioural neuroscience relies on software driven methods for behavioural assessment, but the field lacks cost-effective, robust, open source software for behavioural analysis. Here we propose a novel method which we called as ZebraTrack. It includes cost-effective imaging setup for distraction-free behavioural acquisition, automated tracking using open-source ImageJ software and workflow for extraction of behavioural endpoints. Our ImageJ algorithm is capable of providing control to users at key steps while maintaining automation in tracking without the need for the installation of external plugins. We have validated this method by testing novelty induced anxiety behaviour in adult zebrafish. Our results, in agreement with established findings, showed that during state-anxiety, zebrafish showed reduced distance travelled, increased thigmotaxis and freezing events. Furthermore, we proposed a method to represent both spatial and temporal distribution of choice-based behaviour which is currently not possible to represent using simple videograms. ZebraTrack method is simple and economical, yet robust enough to give results comparable with those obtained from costly proprietary software like Ethovision XT. We have developed and validated a novel cost-effective method for behavioural analysis of adult zebrafish using open-source ImageJ software. Copyright © 2016 Elsevier B.V. All rights reserved.
Applications of thin-film sandwich crystallization platforms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Axford, Danny, E-mail: danny.axford@diamond.ac.uk; Aller, Pierre; Sanchez-Weatherby, Juan
2016-03-24
Crystallization via sandwiches of thin polymer films is presented and discussed. Examples are shown of protein crystallization in, and data collection from, solutions sandwiched between thin polymer films using vapour-diffusion and batch methods. The crystallization platform is optimal for both visualization and in situ data collection, with the need for traditional harvesting being eliminated. In wells constructed from the thinnest plastic and with a minimum of aqueous liquid, flash-cooling to 100 K is possible without significant ice formation and without any degradation in crystal quality. The approach is simple; it utilizes low-cost consumables but yields high-quality data with minimal samplemore » intervention and, with the very low levels of background X-ray scatter that are observed, is optimal for microcrystals.« less
Zanelli, Ugo; Michna, Thomas; Petersson, Carl
2018-03-26
1. A novel method utilizing an internal standard in hepatocytes incubations has been developed and demonstrated to decrease the variability in the determination of intrinsic clearance (CL int ) in this system. The reduced variability was shown to allow differentiation of lower elimination rate constants from noise. 2. The suggested method was able to compensate for a small but systematic error (0.5 µL/min/10 6 cells) caused by an evaporation of approximately 15% of the volume during the incubation time. 3. The approach was validated using six commercial drugs (ketoprofen, tolbutamide, phenacetin, etodolac and quinidine) which were metabolized by different pathways. 4. The suggested internal standard, MSC1815677, was extensively characterized and the acquired data suggest that it fulfills the requirements of an internal standard present during the incubation. The proposed internal standard was stable during the incubation and showed a low potential to inhibit drug metabolizing enzymes and transporters. With MSC1815677 we propose a novel simple, robust and cost-effective method to address the challenges in the estimation of low clearance in hepatocyte incubations.
Structurally efficient inflatable protective device
Nelsen, James M.; Whinery, Larry D.; Gwinn, Kenneth W.; McBride, Donald D.; Luna, Daniel A.; Holder, Joseph P.; Bliton, Richard J.
1997-01-01
An apparatus and method for making a low cost, self-venting, inflatable protective cushion of simple and structurally efficient design with a shape and construction that optimizes the cushion's ability to withstand inflation pressures and impact when deployed which includes a sheet defined by at least one fold line and a plurality of flap portions, each flap portion having a base edge corresponding to a fold line and at least two side edges each extending outwardly from a base edge and ultimately converging to meet each other, the flap portions being folded at the fold line(s) and being joined at corresponding side edges to define an inflatable chamber. The inflatable protective cushion and method for making same may further include a lightweight, low permeability, fabric that optimizes the cushion's ability to withstand inflation pressures and impact when deployed and minimizes the packed volume of the cushion when stored.
Structurally efficient inflatable protective device
Nelsen, J.M.; Whinery, L.D.; Gwinn, K.W.; McBride, D.D.; Luna, D.A.; Holder, J.P.; Bliton, R.J.
1997-03-04
An apparatus and method are disclosed for making a low cost, self-venting, inflatable protective cushion of simple and structurally efficient design with a shape and construction that optimizes the cushion`s ability to withstand inflation pressures and impact when deployed which includes a sheet defined by at least one fold line and a plurality of flap portions, each flap portion having a base edge corresponding to a fold line and at least two side edges each extending outwardly from a base edge and ultimately converging to meet each other, the flap portions being folded at the fold line(s) and being joined at corresponding side edges to define an inflatable chamber. The inflatable protective cushion and method for making same may further include a lightweight, low permeability, fabric that optimizes the cushion`s ability to withstand inflation pressures and impact when deployed and minimizes the packed volume of the cushion when stored. 22 figs.
Structurally efficient inflatable protective device
Nelsen, J.M.; Whinery, L.D.; Gwinn, K.W.; McBride, D.D.; Luna, D.A.; Holder, J.P.; Bliton, R.J.
1996-01-09
An apparatus and method are disclosed for making a low cost, self-venting, inflatable protective cushion of simple and structurally efficient design with a shape and construction that optimizes the cushion`s ability to withstand inflation pressures and impact when deployed which includes a sheet defined by at least one fold line and a plurality of flap portions, each flap portion having a base edge corresponding to a fold line and at least two side edges each extending outwardly from a base edge and ultimately converging to meet each other, the flap portions being folded at the fold line(s) and being joined at corresponding side edges to define an inflatable chamber. The inflatable protective cushion and method for making same may further include a lightweight, low permeability, fabric that optimizes the cushion`s ability to withstand inflation pressures and impact when deployed and minimizes the packed volume of the cushion when stored. 22 figs.
Structurally efficient inflatable protective device
Nelsen, James M.; Whinery, Larry D.; Gwinn, Kenneth W.; McBride, Donald D.; Luna, Daniel A.; Holder, Joseph P.; Bliton, Richard J.
1996-01-01
An apparatus and method for making a low cost, self-venting, inflatable protective cushion of simple and structurally efficient design with a shape and construction that optimizes the cushion's ability to withstand inflation pressures and impact when deployed which includes a sheet defined by at least one fold line and a plurality of flap portions, each flap portion having a base edge corresponding to a fold line and at least two side edges each extending outwardly from a base edge and ultimately converging to meet each other, the flap portions being folded at the fold line(s) and being Joined at corresponding side edges to define an inflatable chamber. The inflatable protective cushion and method for making same may further include a lightweight, low permeability, fabric that optimizes the cushion's ability to withstand inflation pressures and impact when deployed and minimizes the packed volume of the cushion when stored.
Structurally efficient inflatable protective device
Nelsen, James M.; Whinery, Larry D.; Gwinn, Kenneth W.; McBride, Donald D.; Luna, Daniel A.; Holder, Joseph P.; Bliton, Richard J.
1996-01-01
An apparatus and method for making a low cost, self-venting, inflatable protective cushion of simple and structurally efficient design with a shape and construction that optimizes the cushion's ability to withstand inflation pressures and impact when deployed which includes a sheet defined by at least one fold line and a plurality of flap portions, each flap portion having a base edge corresponding to a fold line and at least two side edges each extending outwardly from a base edge and ultimately converging to meet each other, the flap portions being folded at the fold line(s) and being joined at corresponding side edges to define an inflatable chamber. The inflatable protective cushion and method for making same may further include a lightweight, low permeability, fabric that optimizes the cushion's ability to withstand inflation pressures and impact when deployed and minimizes the packed volume of the cushion when stored.
2013-01-01
Background With high quantity and quality data production and low cost, next generation sequencing has the potential to provide new opportunities for plant phylogeographic studies on single and multiple species. Here we present an approach for in silicio chloroplast DNA assembly and single nucleotide polymorphism detection from short-read shotgun sequencing. The approach is simple and effective and can be implemented using standard bioinformatic tools. Results The chloroplast genome of Toona ciliata (Meliaceae), 159,514 base pairs long, was assembled from shotgun sequencing on the Illumina platform using de novo assembly of contigs. To evaluate its practicality, value and quality, we compared the short read assembly with an assembly completed using 454 data obtained after chloroplast DNA isolation. Sanger sequence verifications indicated that the Illumina dataset outperformed the longer read 454 data. Pooling of several individuals during preparation of the shotgun library enabled detection of informative chloroplast SNP markers. Following validation, we used the identified SNPs for a preliminary phylogeographic study of T. ciliata in Australia and to confirm low diversity across the distribution. Conclusions Our approach provides a simple method for construction of whole chloroplast genomes from shotgun sequencing of whole genomic DNA using short-read data and no available closely related reference genome (e.g. from the same species or genus). The high coverage of Illumina sequence data also renders this method appropriate for multiplexing and SNP discovery and therefore a useful approach for landscape level studies of evolutionary ecology. PMID:23497206
Study of CdTe/CdS solar cell at low power density for low-illumination applications
NASA Astrophysics Data System (ADS)
Devi, Nisha; Aziz, Anver; Datta, Shouvik
2016-05-01
In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cell at very low incident power, which gives good efficiency.
Pang, Huan; Zhang, Yizhou; Cheng, Tao; Lai, Wen-Yong; Huang, Wei
2015-10-14
Uniform manganese hexacyanoferrate hydrate nanocubes are prepared via a simple chemical precipitation method at room temperature. Due to both micro/mesopores of the Prussian blue analogue and nanocubic structures, the manganese hexacyanoferrate hydrate nanocubes allow the efficient charge transfer and mass transport for electrolyte solution and chemical species. Thus, the manganese hexacyanoferrate hydrate nanocube electrode shows a good rate capability and cycling stability for electrochemical capacitors. Furthermore, electrodes modified with manganese hexacyanoferrate hydrate nanocubes demonstrate a sensitive electrochemical response to hydrogen peroxide (H2O2) in buffer solutions with a high selectivity.
Smart photonic coating as a new visualization technique of strain deformation of metal plates
NASA Astrophysics Data System (ADS)
Fudouzi, Hiroshi; Sawada, Tsutomu; Tanaka, Yoshikazu; Ario, Ichiro; Hyakutake, Tsuyoshi; Nishizaki, Itaru
2012-04-01
We will present a simple and low cost method to visualize local strain distribution in deformed aluminum plates. In this study, aluminum plates were coated with opal photonic crystal film with tunable structural color. The photonic crystal films consist of a silicone elastomer that contains an array of submicron polystyrene colloidal particles. When the aluminum sheets were stretched, the change in the spacing of the colloidal particles in the opal film alters the color of the film. This approach could be useful as a new strain gauge having a visual indicator to detect mechanical deformation.
Transdermal Diagnosis of Malaria Using Vapor Nanobubbles.
Lukianova-Hleb, Ekaterina; Bezek, Sarah; Szigeti, Reka; Khodarev, Alexander; Kelley, Thomas; Hurrell, Andrew; Berba, Michail; Kumar, Nirbhay; D'Alessandro, Umberto; Lapotko, Dmitri
2015-07-01
A fast, precise, noninvasive, high-throughput, and simple approach for detecting malaria in humans and mosquitoes is not possible with current techniques that depend on blood sampling, reagents, facilities, tedious procedures, and trained personnel. We designed a device for rapid (20-second) noninvasive diagnosis of Plasmodium falciparum infection in a malaria patient without drawing blood or using any reagent. This method uses transdermal optical excitation and acoustic detection of vapor nanobubbles around intraparasite hemozoin. The same device also identified individual malaria parasite-infected Anopheles mosquitoes in a few seconds and can be realized as a low-cost universal tool for clinical and field diagnoses.
NASA Astrophysics Data System (ADS)
Turchiello, Rozane de F.; Pereira, Luiz A. A.; Gómez, Sergio L.
2017-07-01
This paper presents a simple and affordable experiment on the thermal lens effect, suitable for an undergraduate educational laboratory or as a tabletop demonstration in a lecture on nonlinear optics. Such an experiment exploits the formation of a lens in an absorbing medium illuminated by a laser beam with a Gaussian intensity profile. As an absorber, we use a commercial soy sauce, which exhibits a strong thermal lensing effect. Additionally, we show how to measure the radius of a Gaussian beam using the knife-edge method, and how to estimate the focal length of the induced thermal lens.
Experience with modified aerospace reliability and quality assurance method for wind turbines
NASA Technical Reports Server (NTRS)
Klein, W. E.
1982-01-01
The SR&QA approach assures that the machine is not hazardous to the public or operating personnel, can operate unattended on a utility grid, demonstrates reliability operation, and helps establish the quality assurance and maintainability requirements for future wind turbine projects. The approach consisted of modified failure modes and effects analysis (FMEA) during the design phase, minimal hardware inspection during parts fabrication, and three simple documents to control activities during machine construction and operation. Five years experience shows that this low cost approach works well enough that it should be considered by others for similar projects.
Pinto, Joana; Silva, Vera L M; Silva, Ana M G; Silva, Artur M S
2015-06-22
A low cost, safe, clean and environmentally benign base-catalyzed cyclodehydration of appropriate β-diketones affording (E)-2-styrylchromones and flavones in good yields is disclosed. Water was used as solvent and the reactions were heated using classical and microwave heating methods, under open and closed vessel conditions. β-Diketones having electron-donating and withdrawing substituents were used to evaluate the reaction scope. The reaction products were isolated in high purity by simple filtration and recrystallization from ethanol, when using 800 mg of the starting diketone under classical reflux heating conditions.
Wang, Feng-Lei; Zhang, Li-Ying; Zhang, Ya-Fei
2008-11-22
SiC nanowires have been synthesized at 1,600 degrees C by using a simple and low-cost method in a high-frequency induction furnace. The commercial SiO powder and the arc-discharge plasma pretreated carbon black were mixed and used as the source materials. The heating-up and reaction time is less than half an hour. It was found that most of the nanowires have core-shell SiC/SiO(2) nanostructures. The nucleation, precipitation, and growth processes were discussed in terms of the oxide-assisted cluster-solid mechanism.
Pramanik, Subhamay; Bhalla, Vandana; Kumar, Manoj
2013-09-02
Aggregates of hexaphenylbenzene derivatives 3, having pyrene groups form network of fluorescent nanofibres in presence of mercury ions. Further, fluorescent nanofibres of 3-Hg(2+) supramolecular ensemble exhibit sensitive and pronounced response towards the picric acid. In addition, the solution coated paper strips of 3-Hg(2+) supramolecular ensemble can detect picric acid in the range of 2.29 fg/cm(2), thus, providing a simple, portable and low cost method for detection of picric acid in solution and in contact mode. Copyright © 2013 Elsevier B.V. All rights reserved.
Bitella, Giovanni; Rossi, Roberta; Bochicchio, Rocco; Perniola, Michele; Amato, Mariana
2014-10-21
Monitoring soil water content at high spatio-temporal resolution and coupled to other sensor data is crucial for applications oriented towards water sustainability in agriculture, such as precision irrigation or phenotyping root traits for drought tolerance. The cost of instrumentation, however, limits measurement frequency and number of sensors. The objective of this work was to design a low cost "open hardware" platform for multi-sensor measurements including water content at different depths, air and soil temperatures. The system is based on an open-source ARDUINO microcontroller-board, programmed in a simple integrated development environment (IDE). Low cost high-frequency dielectric probes were used in the platform and lab tested on three non-saline soils (ECe1: 2.5 < 0.1 mS/cm). Empirical calibration curves were subjected to cross-validation (leave-one-out method), and normalized root mean square error (NRMSE) were respectively 0.09 for the overall model, 0.09 for the sandy soil, 0.07 for the clay loam and 0.08 for the sandy loam. The overall model (pooled soil data) fitted the data very well (R2 = 0.89) showing a high stability, being able to generate very similar RMSEs during training and validation (RMSE(training) = 2.63; RMSE(validation) = 2.61). Data recorded on the card were automatically sent to a remote server allowing repeated field-data quality checks. This work provides a framework for the replication and upgrading of a customized low cost platform, consistent with the open source approach whereby sharing information on equipment design and software facilitates the adoption and continuous improvement of existing technologies.
Bitella, Giovanni; Rossi, Roberta; Bochicchio, Rocco; Perniola, Michele; Amato, Mariana
2014-01-01
Monitoring soil water content at high spatio-temporal resolution and coupled to other sensor data is crucial for applications oriented towards water sustainability in agriculture, such as precision irrigation or phenotyping root traits for drought tolerance. The cost of instrumentation, however, limits measurement frequency and number of sensors. The objective of this work was to design a low cost “open hardware” platform for multi-sensor measurements including water content at different depths, air and soil temperatures. The system is based on an open-source ARDUINO microcontroller-board, programmed in a simple integrated development environment (IDE). Low cost high-frequency dielectric probes were used in the platform and lab tested on three non-saline soils (ECe1: 2.5 < 0.1 mS/cm). Empirical calibration curves were subjected to cross-validation (leave-one-out method), and normalized root mean square error (NRMSE) were respectively 0.09 for the overall model, 0.09 for the sandy soil, 0.07 for the clay loam and 0.08 for the sandy loam. The overall model (pooled soil data) fitted the data very well (R2 = 0.89) showing a high stability, being able to generate very similar RMSEs during training and validation (RMSEtraining = 2.63; RMSEvalidation = 2.61). Data recorded on the card were automatically sent to a remote server allowing repeated field-data quality checks. This work provides a framework for the replication and upgrading of a customized low cost platform, consistent with the open source approach whereby sharing information on equipment design and software facilitates the adoption and continuous improvement of existing technologies. PMID:25337742
Using a crowdsourced approach for monitoring water level in a remote Kenyan catchment
NASA Astrophysics Data System (ADS)
Weeser, Björn; Jacobs, Suzanne; Rufino, Mariana; Breuer, Lutz
2017-04-01
Hydrological models or effective water management strategies only succeed if they are based on reliable data. Decreasing costs of technical equipment lower the barrier to create comprehensive monitoring networks and allow both spatial and temporal high-resolution measurements. However, these networks depend on specialised equipment, supervision, and maintenance producing high running expenses. This becomes particularly challenging for remote areas. Low income countries often do not have the capacity to run such networks. Delegating simple measurements to citizens living close to relevant monitoring points may reduce costs and increase the public awareness. Here we present our experiences of using a crowdsourced approach for monitoring water levels in remote catchments in Kenya. We established a low-cost system consisting of thirteen simple water level gauges and a Raspberry Pi based SMS-Server for data handling. Volunteers determine the water level and transmit their records using a simple text message. These messages are automatically processed and real-time feedback on the data quality is given. During the first year, more than 1200 valid records with high quality have been collected. In summary, the simple techniques for data collecting, transmitting and processing created an open platform that has the potential for reaching volunteers without the need for special equipment. Even though the temporal resolution of measurements cannot be controlled and peak flows might be missed, this data can still be considered as a valuable enhancement for developing management strategies or for hydrological modelling.
[Calculation of workers' health care costs].
Rydlewska-Liszkowska, Izabela
2006-01-01
In different health care systems, there are different schemes of organization and principles of financing activities aimed at ensuring the working population health and safety. Regardless of the scheme and the range of health care provided, economists strive for rationalization of costs (including their reduction). This applies to both employers who include workers' health care costs into indirect costs of the market product manufacture and health care institutions, which provide health care services. In practice, new methods of setting costs of workers' health care facilitate regular cost control, acquisition of detailed information about costs, and better adjustment of information to planning and control needs in individual health care institutions. For economic institutions and institutions specialized in workers' health care, a traditional cost-effect calculation focused on setting costs of individual products (services) is useful only if costs are relatively low and the output of simple products is not very high. But when products form aggregates of numerous actions like those involved in occupational medicine services, the method of activity based costing (ABC), representing the process approach, is much more useful. According to this approach costs are attributed to the product according to resources used during different activities involved in its production. The calculation of costs proceeds through allocation of all direct costs for specific processes in a given institution. Indirect costs are settled on the basis of resources used during the implementation of individual tasks involved in the process of making a new product. In this method, so called map of processes/actions consisted in the manufactured product and their interrelations are of particular importance. Advancements in the cost-effect for the management of health care institutions depend on their managerial needs. Current trends in this regard primarily depend on treating all cost reference subjects as cost objects and taking account of all their interrelations. Final products, specific assignments, resources and activities may all be regarded as cost objects. The ABC method is characterized by a very high informative value in terms of setting prices of products in the area of workers' health care. It also facilitates the assessment of costs of individual activities under a multidisciplinary approach to health care and the setting costs of varied products. The ABC method provides precise data on the consumption of resources, such as human labor or various materials.
Wijemanne, Nimanthi; Soysa, Preethi; Wijesundara, Sulochana; Perera, Hemamali
2018-01-01
Uric acid and hypoxanthine are produced in the catabolism of purine. Abnormal urinary levels of these products are associated with many diseases and therefore it is necessary to have a simple and rapid method to detect them. Hence, we report a simple reverse phase high performance liquid chromatography (HPLC/UV) technique, developed and validated for simultaneous analysis of uric acid, hypoxanthine, and creatinine in human urine. Urine was diluted appropriately and eluted with C-18 column 100 mm × 4.6 mm with a C-18 precolumn 25 mm × 4.6 mm in series. Potassium phosphate buffer (20 mM, pH 7.25) at a flow rate of 0.40 mL/min was employed as the solvent and peaks were detected at 235 nm. Tyrosine was used as the internal standard. The experimental conditions offered a good separation of analytes without interference of endogenous substances. The calibration curves were linear for all test compounds with a regression coefficient, r 2 > 0.99. Uric acid, creatinine, tyrosine, and hypoxanthine were eluted at 5.2, 6.1, 7.2, and 8.3 min, respectively. Intraday and interday variability were less than 4.6% for all the analytes investigated and the recovery ranged from 98 to 102%. The proposed HPLC procedure is a simple, rapid, and low cost method with high accuracy with minimum use of organic solvents. This method was successfully applied for the determination of creatinine, hypoxanthine, and uric acid in human urine.
NASA Astrophysics Data System (ADS)
Zhang, Chun-Sen; Zhang, Meng-Meng; Zhang, Wei-Xing
2017-01-01
This paper outlines a low-cost, user-friendly photogrammetric technique with nonmetric cameras to obtain excavation site digital sequence images, based on photogrammetry and computer vision. Digital camera calibration, automatic aerial triangulation, image feature extraction, image sequence matching, and dense digital differential rectification are used, combined with a certain number of global control points of the excavation site, to reconstruct the high precision of measured three-dimensional (3-D) models. Using the acrobatic figurines in the Qin Shi Huang mausoleum excavation as an example, our method solves the problems of little base-to-height ratio, high inclination, unstable altitudes, and significant ground elevation changes affecting image matching. Compared to 3-D laser scanning, the 3-D color point cloud obtained by this method can maintain the same visual result and has advantages of low project cost, simple data processing, and high accuracy. Structure-from-motion (SfM) is often used to reconstruct 3-D models of large scenes and has lower accuracy if it is a reconstructed 3-D model of a small scene at close range. Results indicate that this method quickly achieves 3-D reconstruction of large archaeological sites and produces heritage site distribution of orthophotos providing a scientific basis for accurate location of cultural relics, archaeological excavations, investigation, and site protection planning. This proposed method has a comprehensive application value.
Reconfigurable ultra-wideband waveform generation with simple photonic devices
NASA Astrophysics Data System (ADS)
Dastmalchi, Mansour; Abtahi, Mohammad; Lemus, David; Rusch, Leslie A.; LaRochelle, Sophie
2012-08-01
We propose and experimentally demonstrate a low cost, low power consumption technique for ultra-wideband pulse shaping. Our approach is based on thermal apodization of two identical linearly chirped fiber Bragg gratings (LCFBG) placed in both arms of a balanced photodetector. Resistive heating elements with low electrical power consumption are used to tune the LCFBG spectral responses. Using a standard gain switched distributed feedback laser as a pulsed optical source and a simple energy detector receiver, we measured a bit error rate of 1.5×10-4 at a data rate of 1 Gb/s after RF transmission over a 1-m link.
Development of a Low-Cost, Noninvasive, Portable Visual Speech Recognition Program.
Kohlberg, Gavriel D; Gal, Ya'akov Kobi; Lalwani, Anil K
2016-09-01
Loss of speech following tracheostomy and laryngectomy severely limits communication to simple gestures and facial expressions that are largely ineffective. To facilitate communication in these patients, we seek to develop a low-cost, noninvasive, portable, and simple visual speech recognition program (VSRP) to convert articulatory facial movements into speech. A Microsoft Kinect-based VSRP was developed to capture spatial coordinates of lip movements and translate them into speech. The articulatory speech movements associated with 12 sentences were used to train an artificial neural network classifier. The accuracy of the classifier was then evaluated on a separate, previously unseen set of articulatory speech movements. The VSRP was successfully implemented and tested in 5 subjects. It achieved an accuracy rate of 77.2% (65.0%-87.6% for the 5 speakers) on a 12-sentence data set. The mean time to classify an individual sentence was 2.03 milliseconds (1.91-2.16). We have demonstrated the feasibility of a low-cost, noninvasive, portable VSRP based on Kinect to accurately predict speech from articulation movements in clinically trivial time. This VSRP could be used as a novel communication device for aphonic patients. © The Author(s) 2016.
Airtightness the simple(CS) way
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, S.
Builders who might buck against such time consuming air sealing methods as polyethylene wrap and the airtight drywall approach (ADA) may respond better to current strategies. One such method, called SimpleCS, has proven especially effective. SimpleCS, pronounced simplex, stands for simple caulk and seal. A modification of the ADA, SimpleCS is an air-sealing management tool, a simplified systems approach to building tight homes. The system address the crucial question of when and by whom various air sealing steps should be done. It avoids the problems that often occur when later contractors cut open polyethylene wrap to drill holes in themore » drywall. The author describes how SimpleCS works, and the cost and training involved.« less
NASA Astrophysics Data System (ADS)
Bravo, Mikel; Angulo-Vinuesa, Xabier; Martin-Lopez, Sonia; Lopez-Amo, Manuel; Gonzalez-Herraez, Miguel
2013-05-01
High-Q resonators have been widely used for sensing purposes. High Q factors normally lead to sharp spectral peaks which accordingly provide a strong sensitivity in spectral interrogation methods. In this work we employ a low-Q ring resonator to develop a high sensitivity sub-micrometric resolution displacement sensor. We use the slow-light effects occurring close to the critical coupling regime to achieve high sensitivity in the device. By tuning the losses in the cavity close to the critical coupling, extremely high group delay variations can be achieved, which in turn introduce strong enhancements of the absorption of the structure. We first validate the concept using an Optical Vector Analyzer (OVA) and then we propose a simple functional scheme for achieving a low-cost interrogation of this kind of sensors.
A Handful of Bacteria: A Simple Activity That Engages Students to Think and Write Like a Scientist
ERIC Educational Resources Information Center
Song, Pengfei
2014-01-01
Non-major students taking science courses to fulfill degree requirements may show low interest in traditional lecture-based classrooms. While professors may try to incorporate hands-on activities to the classroom to foster enthusiasm, the development of a low-cost, low-hazard scienitfic activity that engages students can be challenging. Moreover,…
Atlas of susceptibility to pollution in marinas. Application to the Spanish coast.
Gómez, Aina G; Ondiviela, Bárbara; Fernández, María; Juanes, José A
2017-01-15
An atlas of susceptibility to pollution of 320 Spanish marinas is provided. Susceptibility is assessed through a simple, fast and low cost empirical method estimating the flushing capacity of marinas. The Complexity Tidal Range Index (CTRI) was selected among eleven empirical methods. The CTRI method was selected by means of statistical analyses because: it contributes to explain the system's variance; it is highly correlated to numerical model results; and, it is sensitive to marinas' location and typology. The process of implementation to the Spanish coast confirmed its usefulness, versatility and adaptability as a tool for the environmental management of marinas worldwide. The atlas of susceptibility, assessed through CTRI values, is an appropriate instrument to prioritize environmental and planning strategies at a regional scale. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sample to answer visualization pipeline for low-cost point-of-care blood cell counting
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter
2015-03-01
We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.
Petersen, Albert; Held, Nadja
2017-01-01
Background Substandard and falsified medical products present a serious threat to public health, especially in low- and middle-income countries. Their identification using pharmacopeial analysis is expensive and requires sophisticated equipment and highly trained personnel. Simple, low-cost technologies are required in addition to full pharmacopeial analysis in order to accomplish widespread routine surveillance for poor-quality medicines in low- and middle-income countries. Methods Ten faith-based drug supply organizations in seven countries of Africa and Asia were each equipped with a Minilab of the Global Pharma Health Fund (GPHF, Frankfurt, Germany), suitable for the analysis of about 85 different essential medicines by thin-layer chromatography. Each organization was asked to collect approximately 100 medicine samples from private local medicine outlets, especially from the informal sector. The medicine samples were tested locally according to the Minilab protocols. Medicines which failed Minilab testing were subjected to confirmatory analysis in a WHO-prequalified medicine quality control laboratory in Kenya. Results Out of 869 medicine samples, 21 were confirmed to be substandard or falsified medical products. Twelve did not contain the stated active pharmaceutical ingredient (API), six contained insufficient amounts of the API, and three showed insufficient dissolution of the API. The highest proportion of substandard and falsified medicines was found in Cameroon (7.1%), followed by the Democratic Republic of Congo (2.7%) and Nigeria (1.1%). Antimalarial medicines were most frequently found to be substandard or falsified (9.5% of all antimalarials). Thin-layer chromatography according to the Minilab protocols was found to be specific and reproducible in the identification of medicines which did not contain the stated API. Since only samples which failed Minilab testing were subjected to confirmatory testing using pharmacopeial methods, this study did not assess the sensitivity of the Minilab methodology in the detection of substandard medicines, and may underestimate the prevalence of poor-quality medicines. Conclusions Surveillance for poor-quality medicines can be carried out by local organizations in low- and middle-income countries using a simple, low-cost technology. Such surveillance can identify an important subgroup of the circulating substandard and falsified medical products and can help to prevent them from causing harm in patients. A collaboration of the national drug regulatory authorities with faith-based organizations and other NGOs may therefore represent a promising strategy towards the Sustainable Development Goal of “ensuring access to quality medicines”. PMID:28877208
A Simple, Low-Cost Conductive Composite Material for 3D Printing of Electronic Sensors
Leigh, Simon J.; Bradley, Robert J.; Purssell, Christopher P.; Billson, Duncan R.; Hutchins, David A.
2012-01-01
3D printing technology can produce complex objects directly from computer aided digital designs. The technology has traditionally been used by large companies to produce fit and form concept prototypes (‘rapid prototyping’) before production. In recent years however there has been a move to adopt the technology as full-scale manufacturing solution. The advent of low-cost, desktop 3D printers such as the RepRap and Fab@Home has meant a wider user base are now able to have access to desktop manufacturing platforms enabling them to produce highly customised products for personal use and sale. This uptake in usage has been coupled with a demand for printing technology and materials able to print functional elements such as electronic sensors. Here we present formulation of a simple conductive thermoplastic composite we term ‘carbomorph’ and demonstrate how it can be used in an unmodified low-cost 3D printer to print electronic sensors able to sense mechanical flexing and capacitance changes. We show how this capability can be used to produce custom sensing devices and user interface devices along with printed objects with embedded sensing capability. This advance in low-cost 3D printing with offer a new paradigm in the 3D printing field with printed sensors and electronics embedded inside 3D printed objects in a single build process without requiring complex or expensive materials incorporating additives such as carbon nanotubes. PMID:23185319
ERIC Educational Resources Information Center
Rossi, Sergio; Benaglia, Maurizio; Brenna, Davide; Porta, Riccardo; Orlandi, Manuel
2015-01-01
A simple procedure to convert protein data bank files (.pdb) into a stereolithography file (.stl) using VMD software (Virtual Molecular Dynamic) is reported. This tutorial allows generating, with a very simple protocol, three-dimensional customized structures that can be printed by a low-cost 3D-printer, and used for teaching chemical education…
Low fidelity, high quality: a model for e-learning.
Gordon, Morris; Chandratilake, Madawa; Baker, Paul
2013-08-01
E-learning continues to proliferate as a method to deliver continuing medical education. The effectiveness of e-learning has been widely studied, showing that it is as effective as traditional forms of education. However, most reports focus on whether the e-learning is effective, rather than discussing innovations to allow clinical educators to ask 'how' and 'why' it is effective, and to facilitate local reproduction. Previous work has set out a number of barriers to the introduction of e-learning interventions. Cost, the time to produce interventions, and the training requirements for educators and trainees have all been identified as barriers. We set out to design an e-learning intervention on paediatric prescribing that could address these issues using a low-fidelity approach, and report our methods so as to allow interested readers to use a similar approach. Using low-cost, readily accessible tools and applying appropriate educational theory, the intervention was produced in a short period of time. As part of a randomised controlled trial, long-term retention of prescribing skills was demonstrated, with significantly higher prescribing skill scores in the e-learning group at 4 and 12 weeks (p < 0.0001). Feedback was universally positive, with Likert responses suggesting that it was useful, convenient and easy to use. A low-fidelity approach to designing can successfully overcome many of the barriers to the introduction of e-learning. The design model described is simple and can be used by clinical teachers to support local development. Further research could investigate the experiences of these clinicians using this method of instructional design. © 2013 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Powless, Amy J.; Feekin, Lauren E.; Hutcheson, Joshua A.; Alapat, Daisy V.; Muldoon, Timothy J.
2016-03-01
Point-of-care approaches for 3-part leukocyte differentials (granulocyte, monocyte, and lymphocyte), traditionally performed using a hematology analyzer within a panel of tests called a complete blood count (CBC), are essential not only to reduce cost but to provide faster results in low resource areas. Recent developments in lab-on-a-chip devices have shown promise in reducing the size and reagents used, relating to a decrease in overall cost. Furthermore, smartphone diagnostic approaches have shown much promise in the area of point-of-care diagnostics, but the relatively high per-unit cost may limit their utility in some settings. We present here a method to reduce computing cost of a simple epi-fluorescence imaging system using a Raspberry Pi (single-board computer, <$40) to perform a 3-part leukocyte differential comparable to results from a hematology analyzer. This system uses a USB color camera in conjunction with a leukocyte-selective vital dye (acridine orange) in order to determine a leukocyte count and differential from a low volume (<20 microliters) of whole blood obtained via fingerstick. Additionally, the system utilizes a "cloud-based" approach to send image data from the Raspberry Pi to a main server and return results back to the user, exporting the bulk of the computational requirements. Six images were acquired per minute with up to 200 cells per field of view. Preliminary results showed that the differential count varied significantly in monocytes with a 1 minute time difference indicating the importance of time-gating to produce an accurate/consist differential.
Role of cytopathology in cancer control in low-resource settings: sub-Saharan Africa's perspective.
Thomas, Jaiyeola
2011-03-01
Cancer is an emerging public health problem in Africa especially with increasing exposure to risky life styles, environmental carcinogens and emergence of AIDS-associated cancers. Of the WHO estimated 7.9 million cancer-related deaths in 2007 more than 72% occurred in the low- and middle-income countries and 80% presented in the late stages. To implement the WHO resolution on cancer control programs in these settings, feasible evidence-based interventions for prevention, early diagnosis and detection need to be widely introduced. Fundamental to appropriate cancer treatment and statistics is accurate diagnosis. In low-resource settings, the diagnostic techniques and procedures should be reliable, cost-effective, simple and acceptable to patients. In addition, the required equipment should be affordable, requiring minimal maintenance and with readily available consumables. Cytology, as a simple standardized low-technology procedure, fulfills these criteria and is most effective in addressing the major components of cancer control programs in these areas. The major obstacles to its widespread establishment are lack of awareness and inadequate numbers of trained personnel compounded by sociopolitical factors, poor national planning and implementation. Rather than investing in new technology or alternative screening methods, efforts should focus on the education and training of local personnel, as feasible options, to improve the chances of implementing meaningful cancer control programs.
Yi, Rongxing; Yang, Xinyan; Zhou, Ran; Li, Jiaming; Yu, Huiwu; Hao, Zhongqi; Guo, Lianbo; Li, Xiangyou; Lu, Yongfeng; Zeng, Xiaoyan
2018-05-18
To detect available heavy metals in soil using laser-induced breakdown spectroscopy (LIBS) and improve its poor detection sensitivity, a simple and low cost sample pretreatment method named solid-liquid-solid transformation was proposed. By this method, available heavy metals were extracted from soil through ultrasonic vibration and centrifuging and then deposited on a glass slide. Utilization of this solid-liquid-solid transformation method, available Cd and Pb elements in soil were detected successfully. The results show that the regression coefficients of calibration curves for soil analyses reach to more than 0.98. The limits of detection could reach to 0.067 and 0.94 ppm for available Cd and Pb elements in soil under optimized conditions, respectively, which are much better than those obtained by conventional LIBS.
[Cost variation in care groups?
Mohnen, S M; Molema, C C M; Steenbeek, W; van den Berg, M J; de Bruin, S R; Baan, C A; Struijs, J N
2017-01-01
Is the simple mean of the costs per diabetes patient a suitable tool with which to compare care groups? Do the total costs of care per diabetes patient really give the best insight into care group performance? Cross-sectional, multi-level study. The 2009 insurance claims of 104,544 diabetes patients managed by care groups in the Netherlands were analysed. The data were obtained from Vektis care information centre. For each care group we determined the mean costs per patient of all the curative care and diabetes-specific hospital care using the simple mean method, then repeated it using the 'generalized linear mixed model'. We also calculated for which proportion the differences found could be attributed to the care groups themselves. The mean costs of the total curative care per patient were €3,092 - €6,546; there were no significant differences between care groups. The mixed model method resulted in less variation (€2,884 - €3,511), and there were a few significant differences. We found a similar result for diabetes-specific hospital care and the ranking position of the care groups proved to be dependent on the method used. The care group effect was limited, although it was greater in the diabetes-specific hospital costs than in the total costs of curative care (6.7% vs. 0.4%). The method used to benchmark care groups carries considerable weight. Simply stated, determining the mean costs of care (still often done) leads to an overestimation of the differences between care groups. The generalized linear mixed model is more accurate and yields better comparisons. However, the fact remains that 'total costs of care' is a faulty indicator since care groups have little impact on them. A more informative indicator is 'costs of diabetes-specific hospital care' as these costs are more influenced by care groups.
An intelligent system for real time automatic defect inspection on specular coated surfaces
NASA Astrophysics Data System (ADS)
Li, Jinhua; Parker, Johné M.; Hou, Zhen
2005-07-01
Product visual inspection is still performed manually or semi automatically in most industries from simple ceramic tile grading to complex automotive body panel paint defect and surface quality inspection. Moreover, specular surfaces present additional challenge to conventional vision systems due to specular reflections, which may mask the true location of objects and lead to incorrect measurements. There are some sophisticated visual inspection methods developed in recent years. Unfortunately, most of them are highly computational. Systems built on those methods are either inapplicable or very costly to achieve real time inspection. In this paper, we describe an integrated low-cost intelligent system developed to automatically capture, extract, and segment defects on specular surfaces with uniform color coatings. The system inspects and locates regular surface defects with lateral dimensions as small as a millimeter. The proposed system is implemented on a group of smart cameras using its on-board processing ability to achieve real time inspection. The experimental results on real test panels demonstrate the effectiveness and robustness of proposed system.
Tan, Qunyou; Zhang, Li; Zhang, Liangke; Teng, Yongzhen; Zhang, Jingqing
2012-01-01
Pyridostigmine bromide (PTB) is a highly soluble and extremely bitter drug. Here, an economic complexation technology combined with direct tablet compression method has been developed to meet the requirements of a patient friendly dosage known as taste-masked dispersible tablets loaded PTB (TPDPTs): (1) TPDPTs should have optimal disintegration and good physical resistance (hardness); (2) a low-cost, simple but practical preparation method suitable for industrial production is preferred from a cost perspective. Physicochemical properties of the inclusion complex of PTB with beta-cyclodextrin were investigated by Fourier transformed infrared spectroscopy, differential scanning calorimetry and UV spectroscopy. An orthogonal design was chosen to properly formulate TPDPTs. All volunteers regarded acceptable bitterness of TPDPTs. The properties including disintegration time, weight variation, friability, hardness, dispersible uniformity and drug content of TPDPTs were evaluated. The dissolution profile of TPDPTs in distilled water exhibited a fast rate. Pharmacokinetic results demonstrated that TPDPTs and the commercial tablets were bioequivalent.
Dorr, Ricardo; Ozu, Marcelo; Parisi, Mario
2007-04-15
Water channels (aquaporins) family members have been identified in central nervous system cells. A classic method to measure membrane water permeability and its regulation is to capture and analyse images of Xenopus laevis oocytes expressing them. Laboratories dedicated to the analysis of motion images usually have powerful equipment valued in thousands of dollars. However, some scientists consider that new approaches are needed to reduce costs in scientific labs, especially in developing countries. The objective of this work is to share a very low-cost hardware and software setup based on a well-selected webcam, a hand-made adapter to a microscope and the use of free software to measure membrane water permeability in Xenopus oocytes. One of the main purposes of this setup is to maintain a high level of quality in images obtained at brief intervals (shorter than 70 ms). The presented setup helps to economize without sacrificing image analysis requirements.
Imsoonthornruksa, Sumeth; Pruksananonda, Kamthorn; Parnpai, Rangsun; Rungsiwiwut, Ruttachuk; Ketudat-Cairns, Mariena
2015-01-01
To reduce the cost of cytokines and growth factors in stem cell research, a simple method for the production of soluble and biological active human basic fibroblast growth factor (hbFGF) fusion protein in Escherichia coli was established. Under optimal conditions, approximately 60-80 mg of >95% pure hbFGF fusion proteins (Trx-6xHis-hbFGF and 6xHis-hbFGF) were obtained from 1 liter of culture broth. The purified hbFGF proteins, both with and without the fusion tags, were biologically active, which was confirmed by their ability to stimulate proliferation of NIH3T3 cells. The fusion proteins also have the ability to support several culture passages of undifferentiated human embryonic stem cells and induce pluripotent stem cells. This paper describes a low-cost and uncomplicated method for the production and purification of biologically active hbFGF fusion proteins. © 2015 S. Karger AG, Basel.
ERIC Educational Resources Information Center
Deming, David; Dynarski, Susan
2009-01-01
We review the experimental and quasi-experimental research evidence on the causal relationship between college costs and educational attainment, with a particular focus on low-income populations. The weight of the evidence indicates that reducing college costs can increase college entry and persistence. Simple and transparent programs appear to be…
Sampling low-density gypsy moth populations
William E. Wallner; Clive G. Jones; Joseph S. Elkinton; Bruce L. Parker
1991-01-01
The techniques and methodology for sampling gypsy moth, Lymantria dispar L., at low densities, less than 100 egg masses/ha (EM/ha), are compared. Forest managers have constraints of time and cost, and need a useful, simple predictable means to assist them in sampling gypsy moth populations. A comparison of various techniques coupled with results of...
Low carbon steel: Metallurgical structure vs. mechanical properties
NASA Technical Reports Server (NTRS)
Shull, Robert D.
1990-01-01
The objective is to provide a low cost, simple experiment for either demonstration purposes or as a laboratory experiment that will teach the student the importance of the thermal-mechanical history of a metallic alloy in determining that material's mechanical behavior. Hairpins are subjected to various treatments. The experimental equipment and procedures are discussed.
78 FR 71558 - Insurance Cost Information Regulation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-29
... [Docket No. NHTSA-2013-0078] Insurance Cost Information Regulation AGENCY: National Highway Traffic Safety... method for reporting simple and understandable motor vehicle damage susceptibility information to consumers. NHTSA plans to use this information to meet a requirement by Congress that it study and report...
Air Distribution Retrofit Strategies for Affordable Housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, Jordan; Conlin, Francis; Holloway, Parker
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
Air Distribution Retrofit Strategies for Affordable Housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, J.; Conlin, F.; Holloway, Parker
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
Costs of postabortion care in public sector health facilities in Malawi: a cross-sectional survey.
Benson, Janie; Gebreselassie, Hailemichael; Mañibo, Maribel Amor; Raisanen, Keris; Johnston, Heidi Bart; Mhango, Chisale; Levandowski, Brooke A
2015-12-17
Health systems could obtain substantial cost savings by providing safe abortion care rather than providing expensive treatment for complications of unsafely performed abortions. This study estimates current health system costs of treating unsafe abortion complications and compares these findings with newly-projected costs for providing safe abortion in Malawi. We conducted in-depth surveys of medications, supplies, and time spent by clinical personnel dedicated to postabortion care (PAC) for three treatment categories (simple, severe non-surgical, and severe surgical complications) and three uterine evacuation (UE) procedure types (manual vacuum aspiration (MVA), dilation and curettage (D&C) and misoprostol-alone) at 15 purposively-selected public health facilities. Per-case treatment costs were calculated and applied to national, annual PAC caseload data. The median cost per D&C case ($63) was 29% higher than MVA treatment ($49). Costs to treat severe non-surgical complications ($63) were almost five times higher than those of a simple PAC case ($13). Severe surgical complications were especially costly to treat at $128. PAC treatment in public facilities cost an estimated $314,000 annually. Transition to safe, legal abortion would yield an estimated cost reduction of 20%-30%. The method of UE and severity of complications have a large impact on overall costs. With a liberalized abortion law and implementation of induced abortion services with WHO-recommended UE methods, current PAC costs to the health system could markedly decrease.
Quinn, Casey W; Cate, David M; Miller-Lionberg, Daniel D; Reilly, Thomas; Volckens, John; Henry, Charles S
2018-03-20
Metal contamination of natural and drinking water systems poses hazards to public and environmental health. Quantifying metal concentrations in water typically requires sample collection in the field followed by expensive laboratory analysis that can take days to weeks to obtain results. The objective of this work was to develop a low-cost, field-deployable method to quantify trace levels of copper in drinking water by coupling solid-phase extraction/preconcentration with a microfluidic paper-based analytical device. This method has the advantages of being hand-powered (instrument-free) and using a simple "read by eye" quantification motif (based on color distance). Tap water samples collected across Fort Collins, CO, were tested with this method and validated against ICP-MS. We demonstrate the ability to quantify the copper content of tap water within 30% of a reference technique at levels ranging from 20 to 500 000 ppb. The application of this technology, which should be sufficient as a rapid screening tool, can lead to faster, more cost-effective detection of soluble metals in water systems.
Dawood, M K; Liew, T H; Lianto, P; Hong, M H; Tripathy, S; Thong, J T L; Choi, W K
2010-05-21
We report a simple and cost effective method for the synthesis of large-area, precisely located silicon nanocones from nanowires. The nanowires were obtained from our interference lithography and catalytic etching (IL-CE) method. We found that porous silicon was formed near the Au catalyst during the fabrication of the nanowires. The porous silicon exhibited enhanced oxidation ability when exposed to atmospheric conditions or in wet oxidation ambient. Very well located nanocones with uniform sharpness resulted when these oxidized nanowires were etched in 10% HF. Nanocones of different heights were obtained by varying the doping concentration of the silicon wafers. We believe this is a novel method of producing large-area, low cost, well defined nanocones from nanowires both in terms of the control of location and shape of the nanocones. A wide range of potential applications of the nanocone array can be found as a master copy for nanoimprinted polymer substrates for possible biomedical research; as a candidate for making sharp probes for scanning probe nanolithography; or as a building block for field emitting tips or photodetectors in electronic/optoelectronic applications.
Liu, Zhanmin; Yao, Chenhui; Yang, Cuiyun; Wang, Yanming; Wan, Sibao; Huang, Junyi
2018-05-16
Listeria monocytogenes is an important foodborne pathogen, and it can cause severe diseases. Rapid detection of L. monocytogenes is crucial to control this pathogen. A simple and robust strategy based on the cascade of PCR and G-quadruplex DNAzyme catalyzed reaction was used to detect L. monocytogenes. In the presence of hemin and the aptamer formed during PCR, the catalytic horseradish peroxidase-mimicking G-quadruplex DNAzymes allow the colorimetric responses of target DNA from L. monocytogenes. This assay can detect genomic DNA of L. monocytogenes specifically with as low as 50 pg/reaction with the naked eye. Through 20 pork samples assay, visual detection assay had the same results as conventional detection methods, and had a good performance. This is a powerful demonstration of the ability of G-quadruplex DNAzyme to be used for PCR-based assay with significant advantages of high sensitivity, low cost and simple manipulation over existing approaches and offers the opportunity for application in pathogen detection. Copyright © 2018 Elsevier Inc. All rights reserved.
Introducing depolarisation into an inexpensive, simple cloud sensor for standoff aerosol detection
NASA Astrophysics Data System (ADS)
Hopkins, Rebecca J.; Jones, Joseph W.; Barrington, Stephen J.; Foot, Virginia; Baxter, Karen L.
2008-04-01
Light detection and ranging (LIDAR) has potential to be a successful technique for remote detection of airborne biological warfare agents (BWA) that pose a health hazard. Potential techniques for detecting BWA often use spectroscopy to probe molecular structure properties (e.g. UV-fluorescence, Raman and differential absorption spectroscopy). An alternative approach is to differentiate BWA from background interferents by their differing morphology; depolarisation offers one such method. Here, we investigate the feasibility of introducing depolarisation into a short range (approximately 10 m) LIDAR designed to be a simple, inexpensive, low power consumption, portable instrument. T-matrix calculations are presented for a randomly oriented, polydisperse size distribution of Bacillus atrophaeus spheroids. The relationship between backscatter depolarisation and particle aspect ratio is investigated at several incident wavelengths corresponding to those produced by low cost, commercially available laser sources. Through a series of simulations, we determine the best combination of wavelengths for a multi-wavelength instrument design that exploits the concept of normalised depolarisation to determine particle aspect ratio, with the possibility of facilitating BWA detection.
NASA Astrophysics Data System (ADS)
Deng, Jinyi
In this study, high purity bismuth iron oxide (BiFeO3/BFO) nanoparticles of size 50-80 nm have been successfully synthesized by a simple sol-gel method using urea and polyvinyl alcohol at low temperature. X-ray diffraction (XRD) measurement is used to optimize the synthetic process to get highly crystalline and pure phase material. Diffuse reflectance ultraviolet-visible (DRUV-Vis) spectrum indicates that the absorption cut-off wavelength of the nanoparticles is about 620 nm, corresponding to an energy band gap of 2.1 eV. Compared to BaTiO3, BFO has a better degradation of methyl orange under light radiation. Also, photocatalytic tests prove this material to be efficient towards water splitting under simulated solar light to generate hydrogen. The simple synthetic methodology adopted in this paper will be useful in developing low-cost semiconductor materials as effective photocatalysts for hydrogen generation. Photocatalytic tests followed by gas chromatography (GC) analyses show that BiFeO3 generates three times more hydrogen than commercial titania P25 catalyst under the same experimental conditions.
Simple Levelized Cost of Energy (LCOE) Calculator Documentation | Energy
Analysis | NREL Simple Levelized Cost of Energy (LCOE) Calculator Documentation Simple Levelized Cost of Energy (LCOE) Calculator Documentation Transparent Cost Database Button This is a simple : 1). Cost and Performance Adjust the sliders to suitable values for each of the cost and performance
Saturated Salt Solution Method: A Useful Cadaver Embalming for Surgical Skills Training
Hayashi, Shogo; Homma, Hiroshi; Naito, Munekazu; Oda, Jun; Nishiyama, Takahisa; Kawamoto, Atsuo; Kawata, Shinichi; Sato, Norio; Fukuhara, Tomomi; Taguchi, Hirokazu; Mashiko, Kazuki; Azuhata, Takeo; Ito, Masayuki; Kawai, Kentaro; Suzuki, Tomoya; Nishizawa, Yuji; Araki, Jun; Matsuno, Naoto; Shirai, Takayuki; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Fukui, Hidekimi; Ohseto, Kiyoshige; Yukioka, Tetsuo; Itoh, Masahiro
2014-01-01
Abstract This article evaluates the suitability of cadavers embalmed by the saturated salt solution (SSS) method for surgical skills training (SST). SST courses using cadavers have been performed to advance a surgeon's techniques without any risk to patients. One important factor for improving SST is the suitability of specimens, which depends on the embalming method. In addition, the infectious risk and cost involved in using cadavers are problems that need to be solved. Six cadavers were embalmed by 3 methods: formalin solution, Thiel solution (TS), and SSS methods. Bacterial and fungal culture tests and measurement of ranges of motion were conducted for each cadaver. Fourteen surgeons evaluated the 3 embalming methods and 9 SST instructors (7 trauma surgeons and 2 orthopedists) operated the cadavers by 21 procedures. In addition, ultrasonography, central venous catheterization, and incision with cauterization followed by autosuture stapling were performed in some cadavers. The SSS method had a sufficient antibiotic effect and produced cadavers with flexible joints and a high tissue quality suitable for SST. The surgeons evaluated the cadavers embalmed by the SSS method to be highly equal to those embalmed by the TS method. Ultrasound images were clear in the cadavers embalmed by both the methods. Central venous catheterization could be performed in a cadaver embalmed by the SSS method and then be affirmed by x-ray. Lungs and intestines could be incised with cauterization and autosuture stapling in the cadavers embalmed by TS and SSS methods. Cadavers embalmed by the SSS method are sufficiently useful for SST. This method is simple, carries a low infectious risk, and is relatively of low cost, enabling a wider use of cadavers for SST. PMID:25501070
Saturated salt solution method: a useful cadaver embalming for surgical skills training.
Hayashi, Shogo; Homma, Hiroshi; Naito, Munekazu; Oda, Jun; Nishiyama, Takahisa; Kawamoto, Atsuo; Kawata, Shinichi; Sato, Norio; Fukuhara, Tomomi; Taguchi, Hirokazu; Mashiko, Kazuki; Azuhata, Takeo; Ito, Masayuki; Kawai, Kentaro; Suzuki, Tomoya; Nishizawa, Yuji; Araki, Jun; Matsuno, Naoto; Shirai, Takayuki; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Fukui, Hidekimi; Ohseto, Kiyoshige; Yukioka, Tetsuo; Itoh, Masahiro
2014-12-01
This article evaluates the suitability of cadavers embalmed by the saturated salt solution (SSS) method for surgical skills training (SST). SST courses using cadavers have been performed to advance a surgeon's techniques without any risk to patients. One important factor for improving SST is the suitability of specimens, which depends on the embalming method. In addition, the infectious risk and cost involved in using cadavers are problems that need to be solved. Six cadavers were embalmed by 3 methods: formalin solution, Thiel solution (TS), and SSS methods. Bacterial and fungal culture tests and measurement of ranges of motion were conducted for each cadaver. Fourteen surgeons evaluated the 3 embalming methods and 9 SST instructors (7 trauma surgeons and 2 orthopedists) operated the cadavers by 21 procedures. In addition, ultrasonography, central venous catheterization, and incision with cauterization followed by autosuture stapling were performed in some cadavers. The SSS method had a sufficient antibiotic effect and produced cadavers with flexible joints and a high tissue quality suitable for SST. The surgeons evaluated the cadavers embalmed by the SSS method to be highly equal to those embalmed by the TS method. Ultrasound images were clear in the cadavers embalmed by both the methods. Central venous catheterization could be performed in a cadaver embalmed by the SSS method and then be affirmed by x-ray. Lungs and intestines could be incised with cauterization and autosuture stapling in the cadavers embalmed by TS and SSS methods. Cadavers embalmed by the SSS method are sufficiently useful for SST. This method is simple, carries a low infectious risk, and is relatively of low cost, enabling a wider use of cadavers for SST.
Time- and Cost-Efficient Identification of T-DNA Insertion Sites through Targeted Genomic Sequencing
Lepage, Étienne; Zampini, Éric; Boyle, Brian; Brisson, Normand
2013-01-01
Forward genetic screens enable the unbiased identification of genes involved in biological processes. In Arabidopsis, several mutant collections are publicly available, which greatly facilitates such practice. Most of these collections were generated by agrotransformation of a T-DNA at random sites in the plant genome. However, precise mapping of T-DNA insertion sites in mutants isolated from such screens is a laborious and time-consuming task. Here we report a simple, low-cost and time efficient approach to precisely map T-DNA insertions simultaneously in many different mutants. By combining sequence capture, next-generation sequencing and 2D-PCR pooling, we developed a new method that allowed the rapid localization of T-DNA insertion sites in 55 out of 64 mutant plants isolated in a screen for gyrase inhibition hypersensitivity. PMID:23951038
Electrochemical sensing of heavy metal ions with inorganic, organic and bio-materials.
Cui, Lin; Wu, Jie; Ju, Huangxian
2015-01-15
As heavy metal ions severely harm human health, it is important to develop simple, sensitive and accurate methods for their detection in environment and food. Electrochemical detection featured with short analytical time, low power cost, high sensitivity and easy adaptability for in-situ measurement is one of the most developed methods. This review introduces briefly the recent achievements in electrochemical sensing of heavy metal ions with inorganic, organic and bio-materials modified electrodes. In particular, the unique properties of inorganic nanomaterials, organic small molecules or their polymers, enzymes and nucleic acids for detection of heavy metal ions are highlighted. By employing some representative examples, the design and sensing mechanisms of these electrodes are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.
[Nailfold capillaroscopy: relevance to the practice of rheumatology].
Souza, Eduardo José do Rosário E; Kayser, Cristiane
2015-01-01
Nailfold capillaroscopy is a simple, low-cost method, that is extremely important in the evaluation of patients with Raynaud's phenomenon and of patients with systemic sclerosis (SSc) spectrum diseases. Besides its importance for the early diagnosis of SSc, nailfold capillaroscopy is a useful tool to identify scleroderma patients with high risk for development of vascular and visceral complications and death. The inclusion of capillaroscopy in the new classification criteria for SSc of the American College of Rheumatology (ACR) and European League Against Rheumatism (Eular) gives a new impetus to the use and dissemination of the method. In this paper, we present a didactic, non-systematic review on the subject, with emphasis on advances recently described. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.
Gounaridis, Lefteris; Groumas, Panos; Schreuder, Erik; Heideman, Rene; Avramopoulos, Hercules; Kouloumentas, Christos
2016-04-04
It is still a common belief that ultra-high quality-factors (Q-factors) are a prerequisite in optical resonant cavities for high refractive index resolution and low detection limit in biosensing applications. In combination with the ultra-short steps that are necessary when the measurement of the resonance shift relies on the wavelength scanning of a laser source and conventional methods for data processing, the high Q-factor requirement makes these biosensors extremely impractical. In this work we analyze an alternative processing method based on the fast-Fourier transform, and show through Monte-Carlo simulations that improvement by 2-3 orders of magnitude can be achieved in the resolution and the detection limit of the system in the presence of amplitude and spectral noise. More significantly, this improvement is maximum for low Q-factors around 104 and is present also for high intra-cavity losses and large scanning steps making the designs compatible with the low-cost aspect of lab-on-a-chip technology. Using a micro-ring resonator as model cavity and a system design with low Q-factor (104), low amplitude transmission (0.85) and relatively large scanning step (0.25 pm), we show that resolution close to 0.01 pm and detection limit close to 10-7 RIU can be achieved improving the sensing performance by more than 2 orders of magnitude compared to the performance of systems relying on a simple peak search processing method. The improvement in the limit of detection is present even when the simple method is combined with ultra-high Q-factors and ultra-short scanning steps due to the trade-off between the system resolution and sensitivity. Early experimental results are in agreement with the trends of the numerical studies.
Deng, Ming-Jay; Chen, Kai-Wen; Che, Yo-Cheng; Wang, I-Ju; Lin, Chih-Ming; Chen, Jin-Ming; Lu, Kueih-Tzu; Liao, Yen-Fa; Ishii, Hirofumi
2017-01-11
Here we report a simple, scalable, and low-cost method to enhance the electrochemical properties of Mn oxide electrodes for highly efficient and flexible symmetrical supercapacitors. The method involving printing on a printer, pencil-drawing, and electrodeposition is established to fabricate Mn oxide/Ni-nanotube/graphite/paper hybrid electrodes operating with a low-cost, novel urea-LiClO 4 /PVA as gel electrolyte for flexible solid-state supercapacitor (FSSC) devices. The Mn oxide nanofiber/Ni-nanotube/graphite/paper (MNNGP) electrodes in urea-LiClO 4 /PVA gel electrolyte show specific capacitance (C sp ) 960 F/g in voltage region 0.8 V at 5 mV/s and exhibit excellent rates of capacitance retention more than 85% after 5000 cycles. Moreover, the electrochemical behavior of the MNNGP electrodes in urea-LiClO 4 /PVA at operating temperatures 27-110 °C was investigated; the results show that the MNNGP electrodes in urea-LiClO 4 /PVA exhibit outstanding performance (1100 F/g), even at 90 °C. The assembled FSSC devices based on the MNNGP electrodes in urea-LiClO 4 /PVA exhibit great C sp (380 F/g in potential region of 2.0 V at 5 mV/s, exhibiting superior energy density 211.1 W h/kg) and great cycle stability (less than 15% loss after 5000 cycles at 25 mV/s). The oxidation-state change was examined by in situ X-ray absorption spectroscopy. FSSC devices would open new opportunities in developing novel portable, wearable, and roll-up electric devices owing to the cheap, high-performance, wide range of operating temperature, and simple procedures for large-area fabrication.
Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng
2017-01-01
Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.
Saha, Arindam; Jana, Nikhil R
2015-01-14
Although microfluidic approach is widely used in various point of care diagnostics, its implementation in surface enhanced Raman spectroscopy (SERS)-based detection is challenging. This is because SERS signal depends on plasmonic nanoparticle aggregation induced generation of stable electromagnetic hot spots and in currently available microfluidic platform this condition is difficult to adapt. Here we show that SERS can be adapted using simple paper based microfluidic system where both the plasmonic nanomaterials and analyte are used in mobile phase. This approach allows analyte induced controlled particle aggregation and electromagnetic hot spot generation inside the microfluidic channel with the resultant SERS signal, which is highly reproducible and sensitive. This approach has been used for reproducible detection of protein in the pico to femtomolar concentration. Presented approach is simple, rapid, and cost-effective, and requires low sample volume. Method can be extended for SERS-based detection of other biomolecules.
Design Principles for Rapid Prototyping Forces Sensors using 3D Printing.
Kesner, Samuel B; Howe, Robert D
2011-07-21
Force sensors provide critical information for robot manipulators, manufacturing processes, and haptic interfaces. Commercial force sensors, however, are generally not adapted to specific system requirements, resulting in sensors with excess size, cost, and fragility. To overcome these issues, 3D printers can be used to create components for the quick and inexpensive development of force sensors. Limitations of this rapid prototyping technology, however, require specialized design principles. In this paper, we discuss techniques for rapidly developing simple force sensors, including selecting and attaching metal flexures, using inexpensive and simple displacement transducers, and 3D printing features to aid in assembly. These design methods are illustrated through the design and fabrication of a miniature force sensor for the tip of a robotic catheter system. The resulting force sensor prototype can measure forces with an accuracy of as low as 2% of the 10 N measurement range.
NASA Astrophysics Data System (ADS)
Jiang, De Bin; Yuan, Yunsong; Zhao, Deqiang; Tao, Kaiming; Xu, Xuan; Zhang, Yu Xin
2018-05-01
In this work, we demonstrate a novel and simple approach for fabrication of the complex three-dimensional (3D) diatomite/manganese silicate nanosheet composite (DMSNs). The manganese silicate nanosheets are uniformly grown on the inner and outer surface of diatomite with controllable morphology using a hydrothermal method. Such structural features enlarged the specific surface area, resulting in more catalytic active sites. In the heterogeneous Fenton-like reaction, the DMSNs exhibited excellent catalytic capability for the degradation of malachite green (MG). Under optimum condition, 500 mg/L MG solution was nearly 93% decolorized at 70 min in the reaction. The presented results show an enhanced catalytic behavior of the DMSNs prepared by the low-cost natural diatomite material and simple controllable process, which indicates their potential for environmental remediation applications. [Figure not available: see fulltext.
NASA Astrophysics Data System (ADS)
Viboonratanasri, Duangkamon; Pabchanda, Suwat; Prompinit, Panida
2018-05-01
In this study, a simple, rapid and relatively less toxic method for rhodamine 6G dye adsorption on hydrogen-form Y-type zeolite for highly selective nitrite detection was demonstrated. The adsorption behavior was described by Langmuir isotherm and the adsorption process reached the equilibrium promptly within a minute. The developed test papers characterized by fluorescence technique display high sensing performance with wide working range (0.04-20.0 mg L-1) and high selectivity. The test papers show good reproducibility with relative standard deviation (RSD) of 7% for five replicated determinations of 3 mg L-1 of nitrite. The nitrite concentration determined by using the test paper was in the same range as using ion chromatography within a 95% confidence level. The test papers offer advantages in terms of low cost and practical usage enabling them to be a promising candidate for nitrite sensor in environmental samples, food, and fertilizers.
Yin, Kai; Du, Haifeng; Dong, Xinran; Wang, Cong; Duan, Ji-An; He, Jun
2017-10-05
Fog collection is receiving increasing attention for providing water in semi-arid deserts and inland areas. Inspired by the fog harvesting ability of the hydrophobic-hydrophilic surface of Namib desert beetles, we present a simple, low-cost method to prepare a hybrid superhydrophobic-hydrophilic surface. The surface contains micro/nanopatterns, and is prepared by incorporating femtosecond-laser fabricated polytetrafluoroethylene nanoparticles deposited on superhydrophobic copper mesh with a pristine hydrophilic copper sheet. The as-prepared surface exhibits enhanced fog collection efficiency compared with uniform (super)hydrophobic or (super)hydrophilic surfaces. This enhancement can be tuned by controlling the mesh number, inclination angle, and fabrication structure. Moreover, the surface shows excellent anti-corrosion ability after immersing in 1 M HCl, 1 M NaOH, and 10 wt% NaCl solutions for 2 hours. This work may provide insight into fabricating hybrid superhydrophobic-hydrophilic surfaces for efficient atmospheric water collection.
Study of CdTe/CdS solar cell at low power density for low-illumination applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devi, Nisha, E-mail: nishatanwer1989@gmail.com; Aziz, Anver, E-mail: aaziz@jmi.ac.in; Datta, Shouvik
In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cellmore » at very low incident power, which gives good efficiency.« less
Flow cytometry for enrichment and titration in massively parallel DNA sequencing
Sandberg, Julia; Ståhl, Patrik L.; Ahmadian, Afshin; Bjursell, Magnus K.; Lundeberg, Joakim
2009-01-01
Massively parallel DNA sequencing is revolutionizing genomics research throughout the life sciences. However, the reagent costs and labor requirements in current sequencing protocols are still substantial, although improvements are continuously being made. Here, we demonstrate an effective alternative to existing sample titration protocols for the Roche/454 system using Fluorescence Activated Cell Sorting (FACS) technology to determine the optimal DNA-to-bead ratio prior to large-scale sequencing. Our method, which eliminates the need for the costly pilot sequencing of samples during titration is capable of rapidly providing accurate DNA-to-bead ratios that are not biased by the quantification and sedimentation steps included in current protocols. Moreover, we demonstrate that FACS sorting can be readily used to highly enrich fractions of beads carrying template DNA, with near total elimination of empty beads and no downstream sacrifice of DNA sequencing quality. Automated enrichment by FACS is a simple approach to obtain pure samples for bead-based sequencing systems, and offers an efficient, low-cost alternative to current enrichment protocols. PMID:19304748
Meloni, Gabriel N; Bertotti, Mauro
2017-01-01
A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.
Bertotti, Mauro
2017-01-01
A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder. PMID:28753638
Economic feeder for recharging and ``topping off''
NASA Astrophysics Data System (ADS)
Fickett, Bryan; Mihalik, G.
2000-04-01
Increasing the size of the melt charge significantly increases yield and reduces costs. Siemens Solar Industries is optimizing a method to charge additional material after meltdown (top-off) using an external feeder system. A prototype feeder system was fabricated consisting of a hopper and feed delivery system. The low-cost feeder is designed for simple operation and maintenance. The system is capable of introducing up to 60 kg of granular silicon while under vacuum. An isolation valve permits refilling of the hopper while maintaining vacuum in the growth furnace. Using the feeder system in conjunction with Siemens Solar Industries' energy efficient hot zone dramatically reduces power and argon consumption. Throughput is also improved as faster pull speeds can be attained. The increased pull speeds have an even greater impact when the charge size is increased. Further cost reduction can be achieved by refilling the crucible after crystal growth and pulling a second ingot run. Siemens Solar Industries is presently testing the feeder in production.
Overview: Mechanism and Control of a Prosthetic Arm.
Kulkarni, Tushar; Uddanwadiker, Rashmi
2015-09-01
Continuous growth in industrialization and lack of awareness in safety parameters the cases of amputations are growing. The search of safer, simpler and automated prosthetic arms for managing upper limbs is expected. Continuous efforts have been made to design and develop prosthetic arms ranging from simple harness actuated to automated mechanisms with various control options. However due the cost constraints, the automated prosthetic arms are still out of the reach of needy people. Recent data have shown that there is a wide scope to develop a low cost and light weight upper limb prosthesis. This review summarizes the various designs methodologies, mechanisms and control system developed by the researchers and the advances therein. Educating the patient to develop acceptability to prosthesis and using the same for the most basic desired functions of human hand, post amputation care and to improve patient's independent life is equally important. In conclusion it can be interpreted that there is a wide scope in design in an adaptive mechanism for opening and closing of the fingers using other methods of path and position synthesis. Simple mechanisms and less parts may optimize the cost factor. Reduction in the weight of the prosthesis may be achieved using polymers used for engineering applications. Control system will remain never ending challenge for the researchers, but it is essential to maintain the simplicity from the patients perspective.
Agustini, Deonir; Bergamini, Márcio F; Marcolino-Junior, Luiz Humberto
2017-12-15
The tear glucose analysis is an important alternative for the indirect, simple and less invasive monitoring of blood glucose levels. However, the high cost and complex manufacturing process of tear glucose analyzers combined with the need to exchange the sensor after each analysis in the disposable tests prevent widespread application of the tear in glucose monitoring. Here, we present the integration of a biosensor made by the electropolymerization of poly(toluidine blue O) (PTB) and glucose oxidase (GOx) with an electroanalytical microfluidic device of easy assembly based on cotton threads, low cost materials and measurements by microflow injection analysis (µFIA) through passive pumping for performing tear glucose analyses in a simple, rapid and inexpensive way. A high stability between the analyses (RSD = 2.54%) and among the different systems (RSD = 3.13%) was obtained for the determination of glucose, in addition to a wide linear range between 0.075 and 7.5mmolL -1 and a limit of detection of 22.2µmolL -1 . The proposed method was efficiently employed in the determination of tear glucose in non-diabetic volunteers, obtaining a close correlation with their blood glucose levels, simplifying and reducing the costs of the analyses, making the tear glucose monitoring more accessible for the population. Copyright © 2017 Elsevier B.V. All rights reserved.
Structural Solutions for Low-Cost Bamboo Frames: Experimental Tests and Constructive Assessments
Sassu, Mauro; De Falco, Anna; Giresini, Linda; Puppio, Mario Lucio
2016-01-01
Experimental tests and constructive assessments are presented for a simple bamboo framed structure with innovative low-cost and low technology joints, specifically conceived for small buildings in developing countries. Two full scale one-storey bamboo frames have been designed by using the simplest joints solution among three different tested typologies. The entire building process is based on low-technology and natural materials: bamboo canes, wooden cylinders, plywood plates and canapé rods. The first full scale specimen (Unit A) is a one-storey single deck truss structure subjected to monotonic collapse test; the second full scale specimen (Unit B) is a one-storey double deck truss structure used to evaluate the construction time throughout assembling tests. The first full scale specimen showed ductility in collapse and ease in strengthening; the second one showed remarkable ease and speed in assembling structural elements. Finally several constructive solutions are suggested for the design of simple one-storey buildings; they are addressed to four purposes (housing, school, chapel, health center) by the composition of the proposed full scale bamboo frames. Ease of use and maintenance with a low level of technology contribute to application in developing countries although not exclusively. PMID:28773472
Reusable anaerobic system for microbiological studies - A concept
NASA Technical Reports Server (NTRS)
Murawczyk, C.
1971-01-01
Simple, low cost system consists of semirigid incubation chamber with clear Teflon window, airtight zipper and internal compartments for petri dishes or microbial plates. Device interests schools, medical laboratories, and manufacturers of biological and pharmaceutical supplies.
A Small-Scale and Low-Cost Apparatus for the Electrolysis of Water
ERIC Educational Resources Information Center
Eggeen, Per-Odd; Kvittingen, Lise
2004-01-01
The construction of two simple, inexpensive apparatuses that clearly show the electrolysis of water are described. Traditionally the electrolysis of water is conducted in a Hofmann apparatus which is expensive and fragile.
Cai, Longfei; Zhong, Minghua; Li, Huolin; Xu, Chunxiu; Yuan, Biyu
2015-07-01
We describe a simple and cost-effective strategy for rapid fabrication of microfluidic paper-based analytical devices and valves by inkjet printing. NaOH aqueous solution was printed onto a hydrophobic filter paper, which was previously obtained by soaking in a trimethoxyoctadecylsilane-heptane solution, allowing selective wet etching of hydrophobic cellulose to create hydrophilic-hydrophobic contrast with a relatively good resolution. Hexadecyltrimethylammonium bromide (CTMAB)-ethanol solution was printed onto hydrophobic paper to fabricate temperature-controlled valves. At low temperature, CTMAB deposited on the paper is insoluble in aqueous fluid, thus the paper remains hydrophobic. At high temperature, CTMAB becomes soluble so the CTMAB-deposited channel becomes hydrophilic, allowing the wicking of aqueous solution through the valve. We believe that this strategy will be very attractive for the development of simple micro analytical devices for point-of-care applications, including diagnostic testing, food safety control, and environmental monitoring.