Okada, Morihiro; Miller, Thomas C; Roediger, Julia; Shi, Yun-Bo; Schech, Joseph Mat
2017-09-01
Various animal models are indispensible in biomedical research. Increasing awareness and regulations have prompted the adaptation of more humane approaches in the use of laboratory animals. With the development of easier and faster methodologies to generate genetically altered animals, convenient and humane methods to genotype these animals are important for research involving such animals. Here, we report skin swabbing as a simple and noninvasive method for extracting genomic DNA from mice and frogs for genotyping. We show that this method is highly reliable and suitable for both immature and adult animals. Our approach allows a simpler and more humane approach for genotyping vertebrate animals.
Omura, Yoshiaki; Lu, Dominic; O'Young, Brian; Jones, Marilyn; Nihrane, Abdallah; Duvvi, Harsha; Shimotsuura, Yasuhiro; Ohki, Motomu
2015-01-01
There are many methods of detecting cancers including detection of cancer markers by blood test, (which is invasive, time consuming and relatively expensive), detection of cancers by non-invasive methods such as X-Ray, CT scan, and MRI & PET Scan (which are non-invasive and quick but very expensive). Our research was performed to develop new non-invasive, safe, quick economical method of detecting cancers and the 1st author already developed for clinically important non-invasive new methods including early stage of present method using his method of localizing accurate organ representation areas of face, eyebrows, upper lip, lower lip, surface and dorsal part of the tongue, surface backs, and palm side of the hands. This accurate localization of the organ representation area of the different parts of the body was performed using electromagnetic field resonance phenomenon between 2 identical molecules or tissues based on our US patented non-invasive method in 1993. Since year 2000, we developed the following non-invasive diagnostic methods that can be quickly identified by the patented simple non-invasive method without using expensive or bulky instrument at any office or field where there is no electricity or instrument available. The following are examples of non-invasive quick method of diagnosis and treatment of cancers using different approaches: 1) Soft red laser beam scanning of different parts of body; 2) By speaking voice; 3) Visible and invisible characteristic abnormalities on different organ representation areas of the different parts of the body, and 4) Mouth, Hand, and Foot Writings of both right and left side of the body. As a consequence of our latest research, we were able to develop a simple method of detecting cancer from existing recorded electrocardiograms. In this article, we are going to describe the method and result of clinical applications on many different cancers of different organs including lung, esophagus, breast, stomach, colon, uterus, ovary, prostate gland, as well as common bone marrow related malignancies such as Hodgkin's Lymphoma, Non-Hodgkin's Lymphoma, Multiple Myeloma as well as Leukemia.
Noninvasive control of dental calculus removal: qualification of two fluorescence methods
NASA Astrophysics Data System (ADS)
Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Biryukova, T.
2013-02-01
The main condition of periodontitis prevention is the full calculus removal from the teeth surface. This procedure should be fulfilled without harming adjacent unaffected tooth tissues. Nevertheless the problem of sensitive and precise estimating of tooth-calculus interface exists and potential risk of hard tissue damage remains. In this work it was shown that fluorescence diagnostics during calculus removal can be successfully used for precise noninvasive detection of calculus-tooth interface. In so doing the simple implementation of this method free from the necessity of spectrometer using can be employed. Such a simple implementation of calculus detection set-up can be aggregated with the devices of calculus removing.
Fundamental study on non-invasive blood glucose sensing.
Xu, K; Li, Q; Lu, Z; Jiang, J
2002-01-01
Diabetes is a disease which severely threatens the health of human beings. Unfortunately, current monitoring techniques with finger sticks discourage the regular use. Noninvasive spectroscopic measurement of blood glucose is a simple and painless technique, and reduces the long-term health care costs of diabetic patients due to no reagents. It is suitable for home use. Moreover, the establishment of the methodology not only applies to blood glucose noninvasive measurement, but also can be extended to noninvasive measurement of other analytes in body fluid, which will be of important significance for the development of the technique of clinical analysis. In this paper, some fundamental researches, which have been achieved in our laboratory in the field of non-invasive blood glucose measurement, were introduced. 1. Fundamental research was done for the glucose concentrations from simple to complex samples with near and middle infrared spectroscopy: (1) the relationship between the instrument precision and prediction accuracy of the glucose measurement; (2) the change of the result of the quantitative measurement with the change of the complexity of samples; (3) the attempt of increasing the prediction accuracy of the glucose measurement by improving the methods of modeling. The research results showed that it is feasible for non-invasive blood glucose measurement with near and middle infrared spectroscopy in theory, and the experimental results, from simple to complex samples, proved that it is effective for the methodology consisting of hardware and software. 2. According to the characteristics of human body measurement, the effects of measuring conditions on measurement results, such as: (1) the effect of measurement position; (2) the effect of measurement pressure; (3) the effect of measurement site; (4) the effect of measured individual, were investigated. With the fundamental researches, the special problems of human body measurement were solved. In addition, the practical and effective method of noninvasive human blood glucose measurement was proposed.
Non-invasive prediction of forthcoming cirrhosis-related complications
Kang, Wonseok; Kim, Seung Up; Ahn, Sang Hoon
2014-01-01
In patients with chronic liver diseases, identification of significant liver fibrosis and cirrhosis is essential for determining treatment strategies, assessing therapeutic response, and stratifying long-term prognosis. Although liver biopsy remains the reference standard for evaluating the extent of liver fibrosis in patients with chronic liver diseases, several non-invasive methods have been developed as alternatives to liver biopsies. Some of these non-invasive methods have demonstrated clinical accuracy for diagnosing significant fibrosis or cirrhosis in many cross-sectional studies with the histological fibrosis stage as a reference standard. However, non-invasive methods cannot be fully validated through cross-sectional studies since liver biopsy is not a perfect surrogate endpoint marker. Accordingly, recent studies have focused on assessing the performance of non-invasive methods through long-term, longitudinal, follow-up studies with solid clinical endpoints related to advanced stages of liver fibrosis and cirrhosis. As a result, current view is that these alternative methods can independently predict future cirrhosis-related complications, such as hepatic decompensation, liver failure, hepatocellular carcinoma, or liver-related death. The clinical role of non-invasive models seems to be shifting from a simple tool for predicting the extent of fibrosis to a surveillance tool for predicting future liver-related events. In this article, we will summarize recent longitudinal studies of non-invasive methods for predicting forthcoming complications related to liver cirrhosis and discuss the clinical value of currently available non-invasive methods based on evidence from the literature. PMID:24627597
NASA Astrophysics Data System (ADS)
Gabai, Haniel; Baranes-Zeevi, Maya; Zilberman, Meital; Shaked, Natan T.
2013-04-01
We propose an off-axis interferometric imaging system as a simple and unique modality for continuous, non-contact and non-invasive wide-field imaging and characterization of drug release from its polymeric device used in biomedicine. In contrast to the current gold-standard methods in this field, usually based on chromatographic and spectroscopic techniques, our method requires no user intervention during the experiment, and only one test-tube is prepared. We experimentally demonstrate imaging and characterization of drug release from soy-based protein matrix, used as skin equivalent for wound dressing with controlled anesthetic, Bupivacaine drug release. Our preliminary results demonstrate the high potential of our method as a simple and low-cost modality for wide-field imaging and characterization of drug release from drug delivery devices.
A simple technique for measurement of pressure in the tympanitic rumen of cattle.
Turner, C B; Whyte, T D
1978-05-13
The construction and method of use of a simple device for the non-invasive measurement of intra-rumenal pressure is outlined. Results obtained from calves suffering from increased intra-rumenal pressure (bloat) are shown. The method is capable of quantifying pressures involved in bloat and could be used to augment the visual assessment of bloat scoring.
Gajre, Suhas S; Anand, Sneh; Singh, U; Saxena, Rajendra K
2006-01-01
Osteoarthritis (OA) of knee is the most commonly occurring non-fatal irreversible disease, mainly in the elderly population and particularly in female. Various invasive and non-invasive methods are reported for the diagnosis of this articular cartilage pathology. Well known techniques such as X-ray, computed tomography, magnetic resonance imaging, arthroscopy and arthrography are having their disadvantages, and diagnosis of OA in early stages with simple effective noninvasive method is still a biomedical engineering problem. Analyzing knee joint noninvasive signals around knee might give simple solution for diagnosis of knee OA. We used electrical impedance data from knees to compare normal and osteoarthritic subjects during the most common dynamic conditions of the knee, i.e. walking and knee swing. It was found that there is substantial difference in the properties of the walking cycle (WC) and knee swing cycle (KS) signals. In experiments on 90 pathological (combined for KS and WC signals) and 72 normal signals (combined), suitable features were drawn. Then signals were used to classify as normal or pathological. Artificial multilayer feed forward neural network was trained using back propagation algorithm for the classification. On a training data set of 54 signals for KS signals, the classification efficiency for a test set of 54 was 70.37% and 85.19% with and without normalization respectively wrt base impedance. Similarly, the training set of 27 WC signals and test set of 27 signals resulted in 77.78% and 66.67% classification efficiency. The results indicate that dynamic electrical impedance signals have potential to be used as a novel method for noninvasive diagnosis of knee OA.
Noninvasive vacuum integrity tests on fast warm-up traveling-wave tubes
NASA Astrophysics Data System (ADS)
Dallos, A.; Carignan, R. G.
1989-04-01
A method of tube vacuum monitoring that uses the tube's existing internal electrodes as an ion gage is discussed. This method has been refined using present-day instrumentation and has proved to be a precise, simple, and fast method of tube vacuum measurement. The method is noninvasive due to operation of the cathode at low temperature, which minimizes pumping or outgassing. Because of the low current levels to be measured, anode insulator leakage must be low, and the leads must be properly shielded to minimize charging effects. A description of the method, instrumentation used, limitations, and data showing results over a period of 600 days are presented.
NASA Astrophysics Data System (ADS)
Ruan, Shaobo; Qian, Jun; Shen, Shun; Zhu, Jianhua; Jiang, Xinguo; He, Qin; Gao, Huile
2014-08-01
Fluorescent carbon dots (CD) possess impressive potential in bioimaging because of their low photobleaching, absence of optical blinking and good biocompatibility. However, their relatively short excitation/emission wavelengths restrict their application in in vivo imaging. In the present study, a kind of CD was prepared by a simple heat treatment method using glycine as the only precursor. The diameter of CD was lower than 5 nm, and the highest emission wavelength was 500 nm. However, at 600 nm, there was still a relatively strong fluorescent emission, suggesting CD could be used for in vivo imaging. Additionally, several experiments demonstrated that CD possessed good serum stability and low cytotoxicity. In vitro, CD could be taken up into C6 glioma cells in a time- and concentration-dependent manner, with both endosomes and mitochondria involved. In vivo, CD could be used for non-invasive glioma imaging because of its high accumulation in the glioma site of the brain, which was demonstrated by both in vivo imaging and ex vivo tissue imaging. Furthermore, the fluorescent distribution in tissue slices also showed CD distributed in glioma with high intensity, while with a low intensity in normal brain tissue. In conclusion, CD were prepared using a simple method with relatively long excitation and emission wavelengths and could be used for non-invasive glioma imaging.Fluorescent carbon dots (CD) possess impressive potential in bioimaging because of their low photobleaching, absence of optical blinking and good biocompatibility. However, their relatively short excitation/emission wavelengths restrict their application in in vivo imaging. In the present study, a kind of CD was prepared by a simple heat treatment method using glycine as the only precursor. The diameter of CD was lower than 5 nm, and the highest emission wavelength was 500 nm. However, at 600 nm, there was still a relatively strong fluorescent emission, suggesting CD could be used for in vivo imaging. Additionally, several experiments demonstrated that CD possessed good serum stability and low cytotoxicity. In vitro, CD could be taken up into C6 glioma cells in a time- and concentration-dependent manner, with both endosomes and mitochondria involved. In vivo, CD could be used for non-invasive glioma imaging because of its high accumulation in the glioma site of the brain, which was demonstrated by both in vivo imaging and ex vivo tissue imaging. Furthermore, the fluorescent distribution in tissue slices also showed CD distributed in glioma with high intensity, while with a low intensity in normal brain tissue. In conclusion, CD were prepared using a simple method with relatively long excitation and emission wavelengths and could be used for non-invasive glioma imaging. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr02657h
Narayan, Vinayak; Mohammed, Nasser; Savardekar, Amey R; Patra, Devi Prasad; Notarianni, Christina; Nanda, Anil
2018-06-01
Traumatic brain injury (TBI) is a leading cause of pediatric morbidity and mortality worldwide and intracranial pressure (ICP) monitoring plays a crucial role in its management. Based on existing literature, we review the current practicing noninvasive ICP monitoring devices and their accuracy in predicting increased ICP in pediatric TBI. A thorough literature search was conducted on PubMed, Medline, and the Cochrane database, articles were selected systematically and reviewed completely, and relevant data were summarized and discussed. A total of 27 articles pertaining to pediatric TBI were included and reviewed. We found various modalities of noninvasive ICP monitoring devices used over the last few years. The noninvasive modalities so far attempted in pediatric TBI and so reviewed here are transcranial Doppler, optic nerve sheath diameter, otoacoustic emission, near-infrared spectroscopy, contrast-enhanced ultrasonography, and quantitative pupillometry. Invasive monitoring methods are the current gold standard for monitoring ICP; however, complications caused by their invasive nature are of concern. Of all the noninvasive methods based on the literature, we found transcranial Doppler and optic nerve sheath diameter assessment to be the best tools to monitor ICP in pediatric TBI. The promising results and developments of noninvasive ICP monitoring modalities with its ideal features of high sensitivity, diagnostic accuracy, and simple acquisition technique may make it the future of neurointensive monitoring in pediatric TBI. Copyright © 2018 Elsevier Inc. All rights reserved.
Mansoor, Sana; Collyer, Elizabeth; Alkhouri, Naim
2015-06-01
Nonalcoholic fatty liver disease (NAFLD) and its spectrum ranging from simple steatosis to nonalcoholic steatohepatitis (NASH) and fibrosis have been increasing in the pediatric population. The presence and severity of fibrosis in patients with NAFLD are important prognostic factors for the risk of disease progression to cirrhosis. The gold standard for staging liver fibrosis is a liver biopsy. However, given the risks of this procedure, especially in the pediatric population, the development of noninvasive markers to diagnose and monitor progression of NAFLD is desirable. This paper will review recently developed noninvasive methods for diagnosing liver fibrosis in children with NAFLD. These include simple fibrosis scores, advanced biochemical markers, and radiologic imaging studies. Simple fibrosis scores use readily available laboratory tests; available one include AST/ALT ratio, AST to platelet ratio index (APRI), fibrosis (FIB)-4 index, NAFLD fibrosis score (NFS), pediatric NAFLD fibrosis index (PNFI), and pediatric NALFD fibrosis score (PNFS). Advanced biochemical markers include biomarkers of hepatocyte cell death such as cytokeratin 18 fragment levels, and markers of extracellular matrix turnover such as the Enhanced Liver Fibrosis (ELF) test and hyaluronic acid. Radiologic imaging studies estimate liver stiffness as a surrogate for liver fibrosis; these include transient elastography (TE), magnetic resonance elastography (MRE), and acoustic radiation force impulse imaging (ARFI).
Non-invasive absolute measurement of leaf water content using terahertz quantum cascade lasers.
Baldacci, Lorenzo; Pagano, Mario; Masini, Luca; Toncelli, Alessandra; Carelli, Giorgio; Storchi, Paolo; Tredicucci, Alessandro
2017-01-01
Plant water resource management is one of the main future challenges to fight recent climatic changes. The knowledge of the plant water content could be indispensable for water saving strategies. Terahertz spectroscopic techniques are particularly promising as a non-invasive tool for measuring leaf water content, thanks to the high predominance of the water contribution to the total leaf absorption. Terahertz quantum cascade lasers (THz QCL) are one of the most successful sources of THz radiation. Here we present a new method which improves the precision of THz techniques by combining a transmission measurement performed using a THz QCL source, with simple pictures of leaves taken by an optical camera. As a proof of principle, we performed transmission measurements on six plants of Vitis vinifera L. (cv "Colorino"). We found a linear law which relates the leaf water mass to the product between the leaf optical depth in the THz and the projected area. Results are in optimal agreement with the proposed law, which reproduces the experimental data with 95% accuracy. This method may overcome the issues related to intra-variety heterogeneities and retrieve the leaf water mass in a fast, simple, and non-invasive way. In the future this technique could highlight different behaviours in preserving the water status during drought stress.
The Noninvasive Measurement of X-Ray Tube Potential.
NASA Astrophysics Data System (ADS)
Ranallo, Frank Nunzio
In this thesis I briefly describe the design of clinical x-ray imaging systems and also the various methods of measuring x-ray tube potential, both invasive and noninvasive. I also discuss the meaning and usage of the quantities tube potential (kV) and peak tube potential (kVp) with reference to x-ray systems used in medical imaging. I propose that there exist several quantities which describe different important aspects of the tube potential as a function of time. These quantities are measurable and can be well defined. I have developed a list of definitions of these quantities along with suggested names and symbols. I describe the development and physical principles of a superior noninvasive method of tube potential measurement along with the instrumentation used to implement this method. This thesis research resulted in the development of several commercial kVp test devices (or "kVp Meters") for which the actual measurement procedure is simple, rapid, and reliable compared to other methods, invasive or noninvasive. These kVp test devices provide measurements with a high level of accuracy and reliability over a wide range of test conditions. They provide results which are more reliable and clinically meaningful than many other, more primary and invasive methods. The errors inherent in these new kVp test devices were investigated and methods to minimize them are discussed.
Blackworms, Blood Vessel Pulsations and Drug Effects.
ERIC Educational Resources Information Center
Lesiuk, Nalena M.; Drewes, Charles D.
1999-01-01
Introduces the freshwater oligochaete worm, lumbriculus variegatus (common name: blackworms), an organism that is well suited for classroom study because of its closed circulatory system. Describes a set of simple, fast, noninvasive, and inexpensive methods for observing pulsations of the worm's dorsal blood vessels under baseline conditions, and…
Non-invasive body temperature measurement of wild chimpanzees using fecal temperature decline.
Jensen, Siv Aina; Mundry, Roger; Nunn, Charles L; Boesch, Christophe; Leendertz, Fabian H
2009-04-01
New methods are required to increase our understanding of pathologic processes in wild mammals. We developed a noninvasive field method to estimate the body temperature of wild living chimpanzees habituated to humans, based on statistically fitting temperature decline of feces after defecation. The method was established with the use of control measures of human rectal temperature and subsequent changes in fecal temperature over time. The method was then applied to temperature data collected from wild chimpanzee feces. In humans, we found good correspondence between the temperature estimated by the method and the actual rectal temperature that was measured (maximum deviation 0.22 C). The method was successfully applied and the average estimated temperature of the chimpanzees was 37.2 C. This simple-to-use field method reliably estimates the body temperature of wild chimpanzees and probably also other large mammals.
Hatta, Tomoko; Fujinaga, Yasunari; Kadoya, Masumi; Ueda, Hitoshi; Murayama, Hiroaki; Kurozumi, Masahiro; Ueda, Kazuhiko; Komatsu, Michiharu; Nagaya, Tadanobu; Joshita, Satoru; Kodama, Ryo; Tanaka, Eiji; Uehara, Tsuyoshi; Sano, Kenji; Tanaka, Naoki
2010-12-01
To assess the degree of hepatic fat content, simple and noninvasive methods with high objectivity and reproducibility are required. Magnetic resonance imaging (MRI) is one such candidate, although its accuracy remains unclear. We aimed to validate an MRI method for quantifying hepatic fat content by calibrating MRI reading with a phantom and comparing MRI measurements in human subjects with estimates of liver fat content in liver biopsy specimens. The MRI method was performed by a combination of MRI calibration using a phantom and double-echo chemical shift gradient-echo sequence (double-echo fast low-angle shot sequence) that has been widely used on a 1.5-T scanner. Liver fat content in patients with nonalcoholic fatty liver disease (NAFLD, n = 26) was derived from a calibration curve generated by scanning the phantom. Liver fat was also estimated by optical image analysis. The correlation between the MRI measurements and liver histology findings was examined prospectively. Magnetic resonance imaging measurements showed a strong correlation with liver fat content estimated from the results of light microscopic examination (correlation coefficient 0.91, P < 0.001) regardless of the degree of hepatic steatosis. Moreover, the severity of lobular inflammation or fibrosis did not influence the MRI measurements. This MRI method is simple and noninvasive, has excellent ability to quantify hepatic fat content even in NAFLD patients with mild steatosis or advanced fibrosis, and can be performed easily without special devices.
Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT.
Komar, Gaber; Oikonen, Vesa; Sipilä, Hannu; Seppänen, Marko; Minn, Heikki
2012-11-01
The aim of this study was to develop a simple noninvasive method for measuring blood flow using [15O]H2O PET/CT for the head and neck area applicable in daily clinical practice. Fifteen dynamic [15O]H2O PET emission scans with simultaneous online radioactivity measurements of radial arterial blood [Blood-input functions (IFs)] were performed. Two noninvasively obtained population-based input functions were calculated by averaging all Blood-IF curves corrected for patients' body mass and injected dose [standardized uptake value (SUV)-IF] and for body surface area (BSA-IF) and injected dose. Parametric perfusion images were calculated for each set of IFs using a linearized two-compartment model, and values for several tissues were compared using Blood-IF as the gold standard. On comparing all tissues, the correlation between blood flow obtained with the invasive Blood-IF and both SUV-IF and BSA-IF was significant (R2=0.785 with P<0.001 and R2=0.813 with P<0.001, respectively). In individual tissues, the performance of the two noninvasive methods was most reliable in resting muscle and slightly less reliable in tumour and cerebellar regions. In these two tissues, only BSA-IF showed a significant correlation with Blood-IF (R2=0.307 with P=0.032 in tumours and R2=0.398 with P<0.007 in the cerebellum). The BSA-based noninvasive method enables clinically relevant delineation between areas of low and high blood flow in tumours. The blood flow of low-perfusion tissues can be reliably quantified using either of the evaluated noninvasive methods.
Laser and radiofrequency-induced hyperthermia treatment via gold-coated magnetic nanocomposites
Elsherbini, Alsayed AM; Saber, Mahmoud; Aggag, Mohamed; El-Shahawy, Ahmed; Shokier, Hesham AA
2011-01-01
Introduction The current radiofrequency ablation technique requires invasive needle placement. On the other hand, most of the common photothermal therapeutic methods are limited by lack of accuracy of targeting. Gold and magnetic nanoparticles offer the potential to heat tumor tissue selectively at the cellular level by noninvasive interaction with laser and radiofrequency. Methods Gold nanospheres and gold-coated magnetic nanocomposites were used for inducing hyperthermia to treat subcutaneous Ehrlich carcinoma implanted in female mice. Results In mice treated with gold nanospheres, tumors continued to grow but at a slow rate. In contrast, more than 50% of the tumors treated with gold-coated magnetic nanocomposites completely disappeared. Conclusion This simple and noninvasive method shows great promise as a technique for selective magnetic photothermal treatment. PMID:22114479
Transdermal Diagnosis of Malaria Using Vapor Nanobubbles.
Lukianova-Hleb, Ekaterina; Bezek, Sarah; Szigeti, Reka; Khodarev, Alexander; Kelley, Thomas; Hurrell, Andrew; Berba, Michail; Kumar, Nirbhay; D'Alessandro, Umberto; Lapotko, Dmitri
2015-07-01
A fast, precise, noninvasive, high-throughput, and simple approach for detecting malaria in humans and mosquitoes is not possible with current techniques that depend on blood sampling, reagents, facilities, tedious procedures, and trained personnel. We designed a device for rapid (20-second) noninvasive diagnosis of Plasmodium falciparum infection in a malaria patient without drawing blood or using any reagent. This method uses transdermal optical excitation and acoustic detection of vapor nanobubbles around intraparasite hemozoin. The same device also identified individual malaria parasite-infected Anopheles mosquitoes in a few seconds and can be realized as a low-cost universal tool for clinical and field diagnoses.
Non-invasive estimation of dissipation from non-equilibrium fluctuations in chemical reactions.
Muy, S; Kundu, A; Lacoste, D
2013-09-28
We show how to extract an estimate of the entropy production from a sufficiently long time series of stationary fluctuations of chemical reactions. This method, which is based on recent work on fluctuation theorems, is direct, non-invasive, does not require any knowledge about the underlying dynamics and is applicable even when only partial information is available. We apply it to simple stochastic models of chemical reactions involving a finite number of states, and for this case, we study how the estimate of dissipation is affected by the degree of coarse-graining present in the input data.
A multispectral imaging approach for diagnostics of skin pathologies
NASA Astrophysics Data System (ADS)
Lihacova, Ilze; Derjabo, Aleksandrs; Spigulis, Janis
2013-06-01
Noninvasive multispectral imaging method was applied for different skin pathology such as nevus, basal cell carcinoma, and melanoma diagnostics. Developed melanoma diagnostic parameter, using three spectral bands (540 nm, 650 nm and 950 nm), was calculated for nevus, melanoma and basal cell carcinoma. Simple multispectral diagnostic device was established and applied for skin assessment. Development and application of multispectral diagnostics method described further in this article.
O’Meally, Denis; Quinn, Alexander E.; Sarre, Stephen D.; Georges, Arthur; Marshall Graves, Jennifer A.
2009-01-01
Primary cell lines were established from cultures of tail and toe clips of five species of Australian dragon lizards: Tympanocryptis pinguicolla, Tympanocryptis sp., Ctenophorus fordi, Amphibolurus norrisi and Pogona vitticeps. The start of exponential cell growth ranged from 1 to 5 weeks. Cultures from all specimens had fibroblastic morphology. Cell lines were propagated continuously up to ten passages, cryopreserved and recovered successfully. We found no reduction in cell viability after short term (<6 months) storage at −80 °C. Mitotic metaphase chromosomes were harvested from these cell lines and used in differential staining, banding and fluorescent in situ hybridisation. Cell lines maintained normal diploidy in all species. This study reports a simple non-invasive method for establishing primary cell lines from Australian dragon lizards without sacrifice. The method is likely to be applicable to a range of species. Such cell lines provide a virtually unlimited source of material for cytogenetic, evolutionary and genomic studies. PMID:19199067
Enabling skin vaccination using new delivery technologies
Kim, Yeu-Chun; Prausnitz, Mark R.
2011-01-01
The skin is known to be a highly immunogenic site for vaccination, but few vaccines in clinical use target skin largely because conventional intradermal injection is difficult and unreliable to perform. Now, a number of new or newly adapted delivery technologies have been shown to administer vaccine to the skin either by non-invasive or minimally invasive methods. Non-invasive methods include high-velocity powder and liquid jet injection, as well as diffusion-based patches in combination with skin abrasion, thermal ablation, ultrasound, electroporation, and chemical enhancers. Minimally invasive methods are generally based on small needles, including solid microneedle patches, hollow microneedle injections, and tattoo guns. The introduction of these advanced delivery technologies can make the skin a site for simple, reliable vaccination that increases vaccine immunogenicity and offers logistical advantages to improve the speed and coverage of vaccination. PMID:21799951
Enabling skin vaccination using new delivery technologies
Kim, Yeu-Chun; Prausnitz, Mark R.
2011-01-01
The skin is known to be a highly immunogenic site for vaccination, but few vaccines in clinical use target skin largely because conventional intradermal injection is difficult and unreliable to perform. Now, a number of new or newly adapted delivery technologies have been shown to administer vaccine to the skin either by non-invasive or minimally invasive methods. Non-invasive methods include high-velocity powder and liquid jet injection, as well as diffusion-based patches in combination with skin abrasion, thermal ablation, ultrasound, electroporation, and chemical enhancers. Minimally invasive methods are generally based on small needles, including solid microneedle patches, hollow microneedle injections and tattoo guns. The introduction of these advanced delivery technologies can make the skin a site for simple, reliable vaccination that increases vaccine immunogenicity and offers logistical advantages to improve the speed and coverage of vaccination. PMID:21472533
A novel method for fast imaging of brain function, non-invasively, with light
NASA Astrophysics Data System (ADS)
Chance, Britton; Anday, Endla; Nioka, Shoko; Zhou, Shuoming; Hong, Long; Worden, Katherine; Li, C.; Murray, T.; Ovetsky, Y.; Pidikiti, D.; Thomas, R.
1998-05-01
Imaging of the human body by any non-invasive technique has been an appropriate goal of physics and medicine, and great success has been obtained with both Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) in brain imaging. Non-imaging responses to functional activation using near infrared spectroscopy of brain (fNIR) obtained in 1993 (Chance, et al. [1]) and in 1994 (Tamura, et al. [2]) are now complemented with images of pre-frontal and parietal stimulation in adults and pre-term neonates in this communication (see also [3]). Prior studies used continuous [4], pulsed [3] or modulated [5] light. The amplitude and phase cancellation of optical patterns as demonstrated for single source detector pairs affords remarkable sensitivity of small object detection in model systems [6]. The methods have now been elaborated with multiple source detector combinations (nine sources, four detectors). Using simple back projection algorithms it is now possible to image sensorimotor and cognitive activation of adult and pre- and full-term neonate human brain function in times < 30 sec and with two dimensional resolutions of < 1 cm in two dimensional displays. The method can be used in evaluation of adult and neonatal cerebral dysfunction in a simple, portable and affordable method that does not require immobilization, as contrasted to MRI and PET.
Transdermal Diagnosis of Malaria Using Vapor Nanobubbles
Lukianova-Hleb, Ekaterina; Bezek, Sarah; Szigeti, Reka; Khodarev, Alexander; Kelley, Thomas; Hurrell, Andrew; Berba, Michail; Kumar, Nirbhay; D’Alessandro, Umberto
2015-01-01
A fast, precise, noninvasive, high-throughput, and simple approach for detecting malaria in humans and mosquitoes is not possible with current techniques that depend on blood sampling, reagents, facilities, tedious procedures, and trained personnel. We designed a device for rapid (20-second) noninvasive diagnosis of Plasmodium falciparum infection in a malaria patient without drawing blood or using any reagent. This method uses transdermal optical excitation and acoustic detection of vapor nanobubbles around intraparasite hemozoin. The same device also identified individual malaria parasite–infected Anopheles mosquitoes in a few seconds and can be realized as a low-cost universal tool for clinical and field diagnoses. PMID:26079141
Spectral properties of thermal fluctuations on simple liquid surfaces below shot-noise levels.
Aoki, Kenichiro; Mitsui, Takahisa
2012-07-01
We study the spectral properties of thermal fluctuations on simple liquid surfaces, sometimes called ripplons. Analytical properties of the spectral function are investigated and are shown to be composed of regions with simple analytic behavior with respect to the frequency or the wave number. The derived expressions are compared to spectral measurements performed orders of magnitude below shot-noise levels, which is achieved using a novel noise reduction method. The agreement between the theory of thermal surface fluctuations and the experiment is found to be excellent, elucidating the spectral properties of the surface fluctuations. The measurement method requires relatively only a small sample both spatially (few μm) and temporally (~20 s). The method also requires relatively weak light power (~0.5 mW) so that it has a broad range of applicability, including local measurements, investigations of time-dependent phenomena, and noninvasive measurements.
Bacon therapy and furuncular myiasis.
Brewer, T F; Wilson, M E; Gonzalez, E; Felsenstein, D
1993-11-03
To evaluate a simple, noninvasive method for removing fly larvae from patients with furuncular myiasis. Case series. Ambulatory office of a tertiary care center. Three patients who presented with Dermatobia hominis infestation. The patients with D hominis infestation were treated with the application of bacon fat over the larval apertures. Removal of intact larvae. Within 3 hours of the application of bacon, the larvae had migrated sufficiently far out of the skin to be removed with tweezers. Ten larvae were removed with this method. There were no treatment failures or complications. Furuncular myiasis will be seen more frequently in temperate areas as individuals travel to endemic areas. We describe the clinical characteristics of myiasis and a simple method of treatment that permits rapid diagnosis and cure.
Hager, Audrey M; Dringenberg, Hans C
2012-12-01
The rat visual system is structured such that the large (>90 %) majority of retinal ganglion axons reach the contralateral lateral geniculate nucleus (LGN) and visual cortex (V1). This anatomical design allows for the relatively selective activation of one cerebral hemisphere under monocular viewing conditions. Here, we describe the design of a harness and face mask allowing simple and noninvasive monocular occlusion in rats. The harness is constructed from synthetic fiber (shoelace-type material) and fits around the girth region and neck, allowing for easy adjustments to fit rats of various weights. The face mask consists of soft rubber material that is attached to the harness by Velcro strips. Eyeholes in the mask can be covered by additional Velcro patches to occlude either one or both eyes. Rats readily adapt to wearing the device, allowing behavioral testing under different types of viewing conditions. We show that rats successfully acquire a water-maze-based visual discrimination task under monocular viewing conditions. Following task acquisition, interocular transfer was assessed. Performance with the previously occluded, "untrained" eye was impaired, suggesting that training effects were partially confined to one cerebral hemisphere. The method described herein provides a simple and noninvasive means to restrict visual input for studies of visual processing and learning in various rodent species.
[Current radionuclear methods in the diagnosis of regional myocardial circulation disorders].
Felix, R; Winkler, C
1977-01-29
Among nuclear medical diagnostic procedures a distinction can be made between non-invasive and invasive methods. The non-invasive methods serve either to image the still viable myocardium ("cold spot" technique) or for direct visualization of recently infarcted myocardial tissue ("hot spot" technique). These methods have the advantage of simple handling and good reproducibility. Side effects and risks are thus far unknown. Improvement of local dissolution should be aimed at in the future and wound greatly increase diagnostic and topographic security. The invasive procedures always require catheterization of the coronary arteries. This is the reason why they can be performed only with coronary arteriography. The Xenon "wash out" technique permits, with some restrictions, quantitative measurement of the regional flow rate. The "inflow technique" permits determination of perfusion distribution. The possibilities of the "double-radionuclide" scintigramm are discussed. For measurement of activity distribution, sationary detectors are generally preferred. In the case of the time-activity curves with the Xenon "wash out" technique, single detectors offer certain advantages.
ERIC Educational Resources Information Center
Ayed, Ahmad; Eqtait, Faeda; Harazneh, Lubna; Fashafsheh, Imad; Nazzal, Sewar; Talahmeh, Bian; Hajar, Deena; Awawdeh, Rrawan
2015-01-01
Background: Breast self-examination is a simple, very low cost, noninvasive with no special material/tool requirements; and it is an effective diagnostic method for breast cancer which only takes five minutes to apply. Aim of the Study: The study aimed to assess the level of BSE knowledge, attitude, and practice among female nursing students in…
Fábián, Renáta; Kovács, András; Stéger, Viktor; Frank, Krisztián; Egerszegi, István; Oláh, János; Bodó, Szilárd
2017-12-01
The Polled Intersex Syndrome (PIS) is responsible for the absence of horns in homozygous and heterozygous goats causing a female-to-male sex reversal in the homozygous polled genotypic female (XX) goats. A simple and efficient non-invasive method was elaborated to detect the genotypic sex from hair and faecal samples using a pair of primers to amplify the X- and Y-linked alleles of the amelogenin gene. The PCR products were easily distinguishable using agarose gel electrophoresis: we detected an X-specific single band in samples originating from healthy phenotypic females and double (X- and Y-) bands in samples from males. The new PCR method is applicable for diagnosing the sex of PIS-affected animals already as newborn kids, in contrast with the phenotypic findings appearing only after puberty, and thus it may replace the cumbersome chromosome investigations.
Noninvasive Electromagnetic Detection of Bladder Cancer
Cormio, Luigi; Vedruccio, Clarbruno; Leucci, Giorgio; Massenio, Paolo; Di Fino, Giuseppe; Cavaliere, Vincenzo; Carrieri, Giuseppe
2014-01-01
Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. PMID:24563795
A Different Pontic Design for Fiber-Reinforced Composite Bridgeworks: A Clinical Report
Kumbuloḡlu, Ovul; Özdemir, Niler; Aksoy, Gökhan; User, Atilla
2007-01-01
Objectives This clinical report describes a relatively simple but esthetic, non-invasive and functional prosthodontic treatment option for a patient with missing tooth. Methods A patient with a missing maxillary left canine was non-invasively treated with a fiber reinforced composite (FRC) bridgework with an all ceramic (Empress II, Ivoclar Vivadent, Schaan, Liech-tenstein) pontic design, using laboratory technique. Results The restoration has served the patient for 2 year, seemingly without discomfort, and it has not required any maintenance. The patient has kept up with his oral hygiene. Conclusions Although additional clinical experience is necessary, fiber-reinforced composite materials can be used in combination with a lithium disilicate ceramic material in fixed partial dentures. PMID:19212498
Illera, Juan-Carlos; Silván, Gema; Cáceres, Sara; Carbonell, Maria-Dolores; Gerique, Cati; Martínez-Fernández, Leticia; Munro, Coralie; Casares, Miguel
2014-01-01
Monitoring ovarian cycles through hormonal analysis is important in order to improve breeding management of captive elephants, and non-invasive collection techniques are particularly interesting for this purpose. However, there are some practical difficulties in collecting proper samples, and easier and more practical methods may be an advantage for some institutions and/or some animals. This study describes the development and validation of an enzymeimmunoassay (EIA) for progestins in salivary samples of African elephants, Loxodonta africana. Weekly urinary and salivary samples from five non-pregnant elephant cows aged 7-12 years were obtained for 28 weeks and analyzed using EIA. Both techniques correlated positively (r = 0.799; P < 0.001), and the cycle characteristics obtained were identical. The results clearly show that ovarian cycles can be monitored by measuring progestins from salivary samples in the African elephant. This is a simple and non-invasive method that may be a practical alternative to other sampling methods used in the species. © 2014 Wiley Periodicals, Inc.
Abrahamsen, B; Hansen, T B; Høgsberg, I M; Pedersen, F B; Beck-Nielsen, H
1996-01-01
Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BIA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.
Nonalcoholic Fatty Liver Disease: Noninvasive Methods of Diagnosing Hepatic Steatosis
AlShaalan, Rasha; Aljiffry, Murad; Al-Busafi, Said; Metrakos, Peter; Hassanain, Mazen
2015-01-01
Hepatic steatosis is the buildup of lipids within hepatocytes. It is the simplest stage in nonalcoholic fatty liver disease (NAFLD). It occurs in approximately 30% of the general population and as much as 90% of the obese population in the United States. It may progress to nonalcoholic steatohepatitis, which is a state of hepatocellular inflammation and damage in response to the accumulated fat. Liver biopsy remains the gold standard tool to diagnose and stage NAFLD. However, it comes with the risk of complications ranging from simple pain to life-threatening bleeding. It is also associated with sampling error. For these reasons, a variety of noninvasive radiological markers, including ultrasound, computed tomography, magnetic resonance spectroscopy, and the controlled attenuation parameter using transient elastography and Xenon-133 scan have been proposed to increase our ability to diagnose NAFLD, hence avoiding liver biopsy. The aim of this review is to discuss the utility and accuracy of using available noninvasive diagnostic modalities for fatty liver in NAFLD. PMID:25843191
Oral exfoliative cytology as a rapid diagnostic tool for paracoccidioidomycosis.
Talhari, Carolina; de Souza, João Vicente Braga; Parreira, Vilmar José; Reinel, Dieter; Talhari, Sinésio
2008-03-01
Paracoccidioidomycosis is a common deep mycosis in South America. It is caused by the dimorphic fungus Paracoccidioides brasiliensis. We report a case of a 47-year-old Brazilian man with oral lesions due to paracoccidioidomycosis, which was diagnosed by exfoliative cytology without any special staining. We highlight this diagnostic tool as a simple, low-cost, painless, non-invasive and fast method for the diagnosis of paracoccidioidomycosis.
Matsumoto, Masaru; Sugama, Junko; Okuwa, Mayumi; Dai, Misako; Matsuo, Junko; Sanada, Hiromi
2013-01-01
The purpose of this study was to elucidate the body core temperature rhythms of bedridden elderly patients with disorders of consciousness (DOC) in a Japanese hospital using a simple, non-invasive, deep-body thermometer. We measured body core temperature on the surface of abdomen in 10 bedridden elderly patients with DOC continuously over 72 h. A non-heated core body temperature thermometer was used. The cycle of the body core temperature rhythm was initially derived by using the least squares method. Then, based on that rhythm, the mean, amplitude, and times of day of the highest and lowest body temperatures during the optimum cycle were determined using the cosinor method. We found a 24-h cycle in seven of the 10 patients. One patient had a 6-h, one a 12-h, and one a 63-h cycle. The mean value of the cosine curve in the respective optimum cycles was 36.48 ± 0.34 °C, and the amplitude was 0.22 ± 0.09 °C. Of the seven subjects with 24-h cycles, the highest body temperature occurred between 12:58 and 14:44 h in four. In addition to 24-h cycles of core temperature rhythm, short cycles of 12 and 6-h and a long cycle of 63-h were seen. In order to understand the temperature rhythms of bedridden elderly patients with DOC, it is necessary to monitor their core body temperatures, ideally using a simple, non-invasive device. In the future, it will be important to investigate the relationship of the core temperature rhythm to nursing care and living environment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Addison, Paul S; Wang, Rui; Uribe, Alberto A; Bergese, Sergio D
2015-01-01
DPOP (ΔPOP or Delta-POP) is a noninvasive parameter which measures the strength of respiratory modulations present in the pulse oximeter waveform. It has been proposed as a noninvasive alternative to pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. We considered a number of simple techniques for better determining the underlying relationship between the two parameters. It was shown numerically that baseline-induced signal errors were asymmetric in nature, which corresponded to observation, and we proposed a method which combines a least-median-of-squares estimator with the requirement that the relationship passes through the origin (the LMSO method). We further developed a method of normalization of the parameters through rescaling DPOP using the inverse gradient of the linear fitted relationship. We propose that this normalization method (LMSO-N) is applicable to the matching of a wide range of clinical parameters. It is also generally applicable to the self-normalizing of parameters whose behaviour may change slightly due to algorithmic improvements.
Addison, Paul S.; Wang, Rui; Uribe, Alberto A.; Bergese, Sergio D.
2015-01-01
DPOP (ΔPOP or Delta-POP) is a noninvasive parameter which measures the strength of respiratory modulations present in the pulse oximeter waveform. It has been proposed as a noninvasive alternative to pulse pressure variation (PPV) used in the prediction of the response to volume expansion in hypovolemic patients. We considered a number of simple techniques for better determining the underlying relationship between the two parameters. It was shown numerically that baseline-induced signal errors were asymmetric in nature, which corresponded to observation, and we proposed a method which combines a least-median-of-squares estimator with the requirement that the relationship passes through the origin (the LMSO method). We further developed a method of normalization of the parameters through rescaling DPOP using the inverse gradient of the linear fitted relationship. We propose that this normalization method (LMSO-N) is applicable to the matching of a wide range of clinical parameters. It is also generally applicable to the self-normalizing of parameters whose behaviour may change slightly due to algorithmic improvements. PMID:25691912
Noninvasive Mechanical Ventilation in Acute Ventilatory Failure: Rationale and Current Applications.
Esquinas, Antonio M; Benhamou, Maly Oron; Glossop, Alastair J; Mina, Bushra
2017-12-01
Noninvasive ventilation plays a pivotal role in acute ventilator failure and has been shown, in certain disease processes such as acute exacerbation of chronic obstructive pulmonary disease, to prevent and shorten the duration of invasive mechanical ventilation, reducing the risks and complications associated with it. The application of noninvasive ventilation is relatively simple and well tolerated by patients and in the right setting can change the course of their illness. Copyright © 2017 Elsevier Inc. All rights reserved.
Cotton fabric-based electrochemical device for lactate measurement in saliva.
Malon, Radha S P; Chua, K Y; Wicaksono, Dedy H B; Córcoles, Emma P
2014-06-21
Lactate measurement is vital in clinical diagnostics especially among trauma and sepsis patients. In recent years, it has been shown that saliva samples are an excellent applicable alternative for non-invasive measurement of lactate. In this study, we describe a method for the determination of lactate concentration in saliva samples by using a simple and low-cost cotton fabric-based electrochemical device (FED). The device was fabricated using template method for patterning the electrodes and wax-patterning technique for creating the sample placement/reaction zone. Lactate oxidase (LOx) enzyme was immobilised at the reaction zone using a simple entrapment method. The LOx enzymatic reaction product, hydrogen peroxide (H2O2) was measured using chronoamperometric measurements at the optimal detection potential (-0.2 V vs. Ag/AgCl), in which the device exhibited a linear working range between 0.1 to 5 mM, sensitivity (slope) of 0.3169 μA mM(-1) and detection limit of 0.3 mM. The low detection limit and wide linear range were suitable to measure salivary lactate (SL) concentration, thus saliva samples obtained under fasting conditions and after meals were evaluated using the FED. The measured SL varied among subjects and increased after meals randomly. The proposed device provides a suitable analytical alternative for rapid and non-invasive determination of lactate in saliva samples. The device can also be adapted to a variety of other assays that requires simplicity, low-cost, portability and flexibility.
New approach to neurorehabilitation: cranial nerve noninvasive neuromodulation (CN-NINM) technology
NASA Astrophysics Data System (ADS)
Danilov, Yuri P.; Tyler, Mitchel E.; Kaczmarek, Kurt A.; Skinner, Kimberley L.
2014-06-01
Cranial Nerve NonInvasive NeuroModulation (CN-NINM) is a primary and complementary multi-targeted rehabilitation therapy that appears to initiate the recovery of multiple damaged or suppressed brain functions affected by neurological disorders. It is deployable as a simple, home-based device (portable neuromodulation stimulator, or PoNSTM) and training regimen following initial patient training in an outpatient clinic. It may be easily combined with many existing rehabilitation therapies, and may reduce or eliminate the need for more aggressive invasive procedures or possibly decrease total medication intake. CN-NINM uses sequenced patterns of electrical stimulation on the tongue. Our hypothesis is that CN-NINM induces neuroplasticity by noninvasive stimulation of two major cranial nerves: trigeminal (CN-V), and facial (CN-VII). This stimulation excites a natural flow of neural impulses to the brainstem (pons varolli and medulla), and cerebellum, to effect changes in the function of these targeted brain structures, extending to corresponding nuclei of the brainstem. CN-NINM represents a synthesis of a new noninvasive brain stimulation technique with applications in physical medicine, cognitive, and affective neurosciences. Our new stimulation method appears promising for treatment of a full spectrum of movement disorders, and for both attention and memory dysfunction associated with traumatic brain injury.
Invasive and non-invasive diagnosis of cirrhosis and portal hypertension
Kim, Moon Young; Jeong, Woo Kyoung; Baik, Soon Koo
2014-01-01
With advances in the management and treatment of advanced liver disease, including the use of antiviral therapy, a simple, one stage description for advanced fibrotic liver disease has become inadequate. Although refining the diagnosis of cirrhosis to reflect disease heterogeneity is essential, current diagnostic tests have not kept pace with the progression of this new paradigm. Liver biopsy and hepatic venous pressure gradient measurement are the gold standards for the estimation of hepatic fibrosis and portal hypertension (PHT), respectively, and they have diagnostic and prognostic value. However, they are invasive and, as such, cannot be used repeatedly in clinical practice. The ideal noninvasive test should be safe, easy to perform, inexpensive, reproducible as well as to give numerical and accurate results in real time. It should be predictive of long term outcomes related with fibrosis and PHT to allow prognostic stratification. Recently, many types of noninvasive alternative tests have been developed and are under investigation. In particular, imaging and ultrasound based tests, such as transient elastography, have shown promising results. Although most of these noninvasive tests effectively identify severe fibrosis and PHT, the methods available for diagnosing moderate disease status are still insufficient, and further investigation is essential to predict outcomes and individualize therapy in this field. PMID:24764667
Fitzpatrick, Emer; Dhawan, Anil
2014-01-01
The development of non invasive biomarkers of disease has become a major focus of interest in nonalcoholic fatty liver disease (NAFLD). The large prevalence of the disease and the invasive nature of the investigation means that screening with liver biopsy is impractical. In addition to screening, the differentiation of those with simple steatosis vs steatohepatitis and fibrosis is clinically important as the prognosis of each differs. Serum biomarkers may be a combination of simple markers derived from large data sets or direct markers of disease activity. Serum markers of inflammation, apoptosis and oxidative stress in addition to fibrosis have been extensively studied in patients with NAFLD. Other techniques such as transient elastography, magnetic resonance elastography and acoustic radiation force imaging are becoming more established as noninvasive methods of detecting fibrosis in a variety of chronic liver conditions in addition to NAFLD. Newer high throughput methods such as proteomics and glycomics allow the nonhypothesis-driven identification of novel markers and may also potentially contribute to our understanding of the pathogenesis of the condition. This review addresses some of the methodological issues which need to be considered in the search for the ideal biomarker. It is likely that a combination of serum biomarkers and techniques such as transient elastography may provide the optimal diagnostic discrimination however this remains to be proven in large studies. PMID:25152587
Ogawa, Ryohei; Kagiya, Go; Watanabe, Akihiko; Morii, Akihiro; Cui, Zheng-Guo; Kondo, Takashi
2017-01-01
It has been pointed out that ultrasound could be used as a controller for bioprocesses including gene expression since its energy can noninvasively reach deep in the body. Gene expression may be timely and spatially controlled by ultrasound, thus providing necessary bioactive proteins for the targeted tissue in a timely fashion. Although there are many processes involved in gene expression control, one of the most important processes is transcription, and the promoter plays an essential role in it. There are several promoters known to be activated in response to ultrasound irradiation . However, in our opinion, an artificial promoter is more suitable for clinical use. We herein describe simple methods to construct promoters that are responsive to ultrasound irradiation by randomly combining cis-elements (transcription factor binding motifs) and thereby improve its reactivity to ultrasound irradiation .
Brooker, Holly R; Gyamfi, Irene A; Wieckowska, Agnieszka; Brooks, Nicholas J; Mulvihill, Daniel P; Geeves, Michael A
2018-06-21
Life is dependent upon the ability of a cell to rapidly respond to changes in environment. Small perturbations in local environments change the ability of molecules to interact and hence communicate. Hydrostatic pressure provides a rapid non-invasive, fully-reversible method for modulating affinities between molecules both in vivo and in vitro We have developed a simple fluorescence imaging chamber that allows intracellular protein dynamics and molecular events to be followed at pressures up to 200 bar in living cells. Using yeast we investigate the impact of hydrostatic pressure upon cell growth and cell cycle progression. While 100 bar has no affect upon viability, it induces a delay in chromosome segregation, resulting in the accumulation of long-undivided-bent cells, consistent with disruption of the cytoskeletons. This delay is independent of stress signalling and induces synchronisation of cell-cycle progression. Equivalent affects were observed in Candida albicans , with pressure inducing a reversible cell-cycle delay and hyphal growth. We present a simple novel non-invasive fluorescence microscopy based approach to transiently impact molecular dynamics to visualise, dissect and study signalling pathways and cellular processes in living cells. © 2018. Published by The Company of Biologists Ltd.
Current and emerging technologies in melanoma diagnosis: the state of the art
Psaty, Estee L.; Halpern, Allan C.
2017-01-01
Relative to other specialties, dermatologists have been slow to adopt advanced technologic diagnostic aids. After all, most skin disease can be diagnosed by simple visual inspection, and the skin is readily accessible for a diagnostic biopsy. Diagnostic aids such as total body photography and dermoscopy improve the clinician's ability to diagnose melanoma beyond unaided visual inspection, however, and are now considered mainstream methods for early detection. Emerging technologies such as in vivo reflectance confocal microscopy are currently being investigated to determine their utility for noninvasive diagnosis of melanoma. This review summarizes the currently available cutaneous imaging devices and new frontiers in noninvasive diagnosis of skin disease. We anticipate that multimodal systems that combine different imaging technologies will further improve our ability to detect, at the bedside, melanoma at an earlier stage. PMID:19095152
Toson, El-Shatat A; Shiha, Gamal E; El-Mezayen, Hatem A; El-Sharkawy, Aml M
2016-08-01
Evaluation of liver fibrosis in patients infected with hepatitis C virus is highly useful for the diagnosis of the disease as well as therapeutic decision. Our aim was to develop and validate a simple noninvasive score for liver fibrosis staging in chronic hepatitis C (CHC) patients and compare its performance against three published simple noninvasive indexes. CHC patients were divided into two groups: an estimated group (n=70) and a validated group (n=52). Liver fibrosis was tested in biopsies using the Metavair score system. CD4 and CD8 count/percentage were assayed by fluorescence-activated cell sorting analysis. The multivariate discriminant analysis selects a function on the basis of absolute values of five biochemical markers: immune fibrosis index (IFI); score=3.07+3.06×CD4/CD8+0.02×α-fetoprotein (U/l)-0.07×alanine aminotransferase ratio-0.005×platelet count (10/l)-1.4×albumin (g/dl). The IFI score produced areas under curve of 0.949, 0.947, and 0.806 for differentiation of all patient categories [significant fibrosis (F2-F4), advanced fibrosis (F3-F4), and cirrhosis (F4)]. The IFI score, a novel noninvasive test, can be used easily for the prediction of liver fibrosis stage in CHC patients. Our score was more efficient than aspartate aminotransferase to platelet ratio index, fibrosis index, and fibroQ and more suitable for use in Egyptian hepatitis C virus patients.
NASA Astrophysics Data System (ADS)
Ankri, Rinat; Leshem-Lev, Dorit; Lev, Eli I.; Motiei, Menachem; Hochhauser, Edith; Fixler, Dror
2016-03-01
In our study we aim to develop a new, simple and non-invasive method to detect and to treat atherosclerosis. We use gold nanoparticles (GNPs) combined with the diffusion reflection (DR) method to demonstrate the detection of vulnerable atherosclerotic plaques. Our method is based on the fact that macrophages are a major component in the vulnerable plaque and are able to uptake metal nanoparticles that can be discovered by the DR system. Moreover, it is well known that high density lipoprotein (HDL) reduces ASVD by inhibiting pro-inflammatory factors, enabling the specific treatment of atherosclerosis.
Verhaegh, Pauline; Bavalia, Roisin; Winkens, Bjorn; Masclee, Ad; Jonkers, Daisy; Koek, Ger
2018-06-01
Nonalcoholic fatty liver disease is a rapidly increasing health problem. Liver biopsy analysis is the most sensitive test to differentiate between nonalcoholic steatohepatitis (NASH) and simple steatosis (SS), but noninvasive methods are needed. We performed a systematic review and meta-analysis of noninvasive tests for differentiating NASH from SS, focusing on blood markers. We performed a systematic search of the PubMed, Medline and Embase (1990-2016) databases using defined keywords, limited to full-text papers in English and human adults, and identified 2608 articles. Two independent reviewers screened the articles and identified 122 eligible articles that used liver biopsy as reference standard. If at least 2 studies were available, pooled sensitivity (sens p ) and specificity (spec p ) values were determined using the Meta-Analysis Package for R (metafor). In the 122 studies analyzed, 219 different blood markers (107 single markers and 112 scoring systems) were identified to differentiate NASH from simple steatosis, and 22 other diagnostic tests were studied. Markers identified related to several pathophysiological mechanisms. The markers analyzed in the largest proportions of studies were alanine aminotransferase (sens p , 63.5% and spec p , 74.4%) within routine biochemical tests, adiponectin (sensp, 72.0% and spec p , 75.7%) within inflammatory markers, CK18-M30 (sens p , 68.4% and spec p , 74.2%) within markers of cell death or proliferation and homeostatic model assessment of insulin resistance (sens p , 69.0% and spec p , 72.7%) within the metabolic markers. Two scoring systems could also be pooled: the NASH test (differentiated NASH from borderline NASH plus simple steatosis with 22.9% sens p and 95.3% spec p ) and the GlycoNASH test (67.1% sens p and 63.8% spec p ). In the meta-analysis, we found no test to differentiate NASH from SS with a high level of pooled sensitivity and specificity (≥80%). However, some blood markers, when included in scoring systems in single studies, identified patients with NASH with ≥80% sensitivity and specificity. Replication studies and more standardized study designs are urgently needed. At present, no marker or scoring system can be recommended for use in clinical practice to differentiate NASH from simple steatosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Gui, Zhen; Wang, Quanbo; Li, Jinchang; Zhu, Mingchen; Yu, Lili; Xun, Tang; Yan, Feng; Ju, Huangxian
2016-07-01
As an emerging noninvasive blood biomarker, circulating free DNA (cfDNA) can be utilized to assess diagnosis, progression and evaluate prognosis of cancer. However, cfDNAs are not "naked", they can be part of complexes, or are bound to the surface of the cells via proteins, which make the detection more challenging. Here, a simple method for the detection of Ubiquitin-like with PHD and ring finger domains 1 (UHRF1) DNA exacted from serum of breast cancer (BC) has been developed using a novel locked nucleic acid molecular beacon (LNA-MB). In order to enhance the stability and detection efficiency of the probe in biofluids, we design a shared-stem molecular beacon containing a 27-mer loop and a 4-mer stem with DNA/LNA alternating bases. The fluorescence is released in the presence of target. The detection procedure is simple and can be completed within 1h. This method shows a sensitive response to UHRF1 DNA with a dynamic range of 3 orders of magnitude. The limit of detection is 11nM (S/N=3) with excellent selectivity. It can discriminate UHRF1 DNA from three-base mismatched DNA with a high specificity. More importantly, this method can distinguish the expression of serum UHRF1 DNA among 5 breast cancer patients and 5 healthy controls. The mentioned superiority may suggest that this assay can be served as a promising noninvasive detection tool for early BC diagnosis and monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.
New advances in MR-compatible bioartificial liver
Jeffries, Rex E.; Macdonald, Jeffrey M.
2015-01-01
MR-compatible bioartificial liver (BAL) studies have been performed for 30 years and are reviewed. There are two types of study: (i) metabolism and drug studies using multinuclear MRS; primarily short-term (< 8 h) studies; (ii) the use of multinuclear MRS and MRI to noninvasively define the features and functions of BAL systems for long-term liver tissue engineering. In the latter, these systems often undergo not only modification of the perfusion system, but also the construction of MR radiofrequency probes around the bioreactor. We present novel MR-compatible BALs and the use of multinuclear MRS (13C, 19F, 31P) for the noninvasive monitoring of their growth, metabolism and viability, as well as 1H MRI methods for the determination of flow profiles, diffusion, cell distribution, quality assurance and bioreactor integrity. Finally, a simple flexible coil design and circuit, and life support system, are described that can make almost any BAL MR-compatible. PMID:22351642
Equine behavioral enrichment toys as tools for non-invasive recovery of viral and host DNA.
Seeber, Peter A; Soilemetzidou, Sanatana E; East, Marion L; Walzer, Chris; Greenwood, Alex D
2017-09-01
Direct collection of samples from wildlife can be difficult and sometimes impossible. Non-invasive remote sampling for the purpose of DNA extraction is a potential tool for monitoring the presence of wildlife at the individual level, and for identifying the pathogens shed by wildlife. Equine herpesviruses (EHV) are common pathogens of equids that can be fatal if transmitted to other mammals. Transmission usually occurs by nasal aerosol discharge from virus-shedding individuals. The aim of this study was to validate a simple, non-invasive method to track EHV shedding in zebras and to establish an efficient protocol for genotyping individual zebras from environmental DNA (eDNA). A commercially available horse enrichment toy was deployed in captive Grévy's, mountain, and plains zebra enclosures and swabbed after 4-24 hr. Using eDNA extracted from these swabs four EHV strains (EHV-1, EHV-7, wild ass herpesvirus and zebra herpesvirus) were detected by PCR and confirmed by sequencing, and 12 of 16 zebras present in the enclosures were identified as having interacted with the enrichment toy by mitochondrial DNA amplification and sequencing. We conclude that, when direct sampling is difficult or prohibited, non-invasive sampling of eDNA can be a useful tool to determine the genetics of individuals or populations and for detecting pathogen shedding in captive wildlife. © 2017 Wiley Periodicals, Inc.
Simple and effective method to lower body core temperatures of hyperthermic patients.
O'Connor, John P
2017-06-01
Hyperthermia is a potentially life threatening scenario that may occur in patients due to accompanying morbidities, exertion, or exposure to dry and arid environmental conditions. In particular, heat stroke may result from environmental exposure combined with a lack of thermoregulation. Key clinical findings in the diagnosis of heatstroke are (1) a history of heat stress or exposure, (2) a rectal temperature greater than 40 °C, and (3) central nervous system dysfunction (altered mental state, disorientation, stupor, seizures, or coma) (Prendergast and Erickson, 2014 [1]). In these patients, it is important to bring the body's core temperature down to acceptable levels in a short period of time to avoid tissue/organ injury or death (Yoder, 2001; Casa et al., 2007 [2,3]). A number of potential approaches, both non-invasive and invasive, may be used to lower the temperature of these individuals. Non-invasive techniques generally include: evaporative cooling, ice water immersion, whole-body ice packing, strategic ice packing, and convective cooling. Invasive approaches may include gastric lavage or peritoneal lavage (Schraga and Kates [4]). The efficacy of these methods vary and select treatment approaches may be unsuitable for specific individuals (Schraga and Kates [4]). In this work, the effectiveness of radiation cooling of individuals as a stand-alone treatment and comparisons with existing noninvasive techniques are presented. Copyright © 2017 Elsevier Inc. All rights reserved.
Port, Johannes; Tao, Ziran; Junger, Annika; Joppek, Christoph; Tempel, Philipp; Husemann, Kim; Singer, Florian; Latzin, Philipp; Yammine, Sophie; Nagel, Joachim H; Kohlhäufl, Martin
2017-11-01
For the assessment of small airway diseases, a noninvasive double-tracer gas single-breath washout (DTG-SBW) with sulfur hexafluoride (SF 6 ) and helium (He) as tracer components has been proposed. It is assumed that small airway diseases may produce typical ventilation inhomogeneities which can be detected within one single tidal breath, when using two tracer components. Characteristic parameters calculated from a relative molar mass (MM) signal of the airflow during the washout expiration phase are analyzed. The DTG-SBW signal is acquired by subtracting a reconstructed MM signal without tracer gas from the signal measured with an ultrasonic sensor during in- and exhalation of the double-tracer gas for one tidal breath. In this paper, a simple method to determine the reconstructed MM signal is presented. Measurements on subjects with and without obstructive lung diseases including the small airways have shown high reliability and reproducibility of this method.
Infrared thermography: A potential noninvasive tool to monitor udder health status in dairy cows
Sathiyabarathi, M.; Jeyakumar, S.; Manimaran, A.; Jayaprakash, G.; Pushpadass, Heartwin A.; Sivaram, M.; Ramesha, K. P.; Das, D. N.; Kataktalware, Mukund A.; Prakash, M. Arul; Kumar, R. Dhinesh
2016-01-01
The animal husbandry and livestock sectors play a major role in the rural economy, especially for the small and marginal farmers. India has the largest livestock population in the world and ranks first in the milk production. Mastitis is the most common and expensive infectious disease in dairy cattle. The global economic losses per year due to mastitis amounts to USD 35 billion and for Indian dairy industry ₹6000 crores per year. Early detection of mastitis is very important to reduce the economic loss to the dairy farmers and dairy industry. Automated methods for early and reliable detection of mastitis are currently in focus under precision dairying. Skin surface temperature is an important indicator for the diagnosis of cow’s illnesses and for the estimation of their physiological status. Infrared thermography (IRT) is a simple, effective, on-site, and noninvasive method that detects surface heat, which is emitted as infrared radiation and generates pictorial images without causing radiation exposure. In human and bovine medicine, IRT is used as a diagnostic tool for assessment of normal and physiological status. PMID:27847416
Xu, Zhenqiang; Shen, Fangxia; Li, Xiaoguang; Wu, Yan; Chen, Qi; Jie, Xu; Yao, Maosheng
2012-01-01
Exhaled breath condensate (EBC) is increasingly being used as a non-invasive method for disease diagnosis and environmental exposure assessment. By using hydrophobic surface, ice, and droplet scavenging, a simple impaction and condensing based collection method is reported here. Human subjects were recruited to exhale toward the device for 1, 2, 3, and 4 min. The exhaled breath quickly formed into tiny droplets on the hydrophobic surface, which were subsequently scavenged into a 10 µL rolling deionized water droplet. The collected EBC was further analyzed using culturing, DNA stain, Scanning Electron Microscope (SEM), polymerase chain reaction (PCR) and colorimetry (VITEK 2) for bacteria and viruses. Experimental data revealed that bacteria and viruses in EBC can be rapidly collected using the method developed here, with an observed efficiency of 100 µL EBC within 1 min. Culturing, DNA stain, SEM, and qPCR methods all detected high bacterial concentrations up to 7000 CFU/m3 in exhaled breath, including both viable and dead cells of various types. Sphingomonas paucimobilis and Kocuria variants were found dominant in EBC samples using VITEK 2 system. SEM images revealed that most bacteria in exhaled breath are detected in the size range of 0.5–1.0 µm, which is able to enable them to remain airborne for a longer time, thus presenting a risk for airborne transmission of potential diseases. Using qPCR, influenza A H3N2 viruses were also detected in one EBC sample. Different from other devices restricted solely to condensation, the developed method can be easily achieved both by impaction and condensation in a laboratory and could impact current practice of EBC collection. Nonetheless, the reported work is a proof-of-concept demonstration, and its performance in non-invasive disease diagnosis such as bacterimia and virus infections needs to be further validated including effects of its influencing matrix. PMID:22848436
Noninvasive extraction of fetal electrocardiogram based on Support Vector Machine
NASA Astrophysics Data System (ADS)
Fu, Yumei; Xiang, Shihan; Chen, Tianyi; Zhou, Ping; Huang, Weiyan
2015-10-01
The fetal electrocardiogram (FECG) signal has important clinical value for diagnosing the fetal heart diseases and choosing suitable therapeutics schemes to doctors. So, the noninvasive extraction of FECG from electrocardiogram (ECG) signals becomes a hot research point. A new method, the Support Vector Machine (SVM) is utilized for the extraction of FECG with limited size of data. Firstly, the theory of the SVM and the principle of the extraction based on the SVM are studied. Secondly, the transformation of maternal electrocardiogram (MECG) component in abdominal composite signal is verified to be nonlinear and fitted with the SVM. Then, the SVM is trained, and the training results are compared with the real data to ensure the effect of the training. Meanwhile, the parameters of the SVM are optimized to achieve the best performance so that the learning machine can be utilized to fit the unknown samples. Finally, the FECG is extracted by removing the optimal estimation of MECG component from the abdominal composite signal. In order to evaluate the performance of FECG extraction based on the SVM, the Signal-to-Noise Ratio (SNR) and the visual test are used. The experimental results show that the FECG with good quality can be extracted, its SNR ratio is significantly increased as high as 9.2349 dB and the time cost is significantly decreased as short as 0.802 seconds. Compared with the traditional method, the noninvasive extraction method based on the SVM has a simple realization, the shorter treatment time and the better extraction quality under the same conditions.
Rabatin, J T; Gay, P C
1999-08-01
Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.
Radiation-induced cystitis following intracavitary irradiation for superficial bladder cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maatman, T.J.; Novick, A.C.; Montague, D.K.
Intracavitary irradiation is effective in the treatment of noninvasive papillary transitional cell carcinoma and carcinoma in situ of the bladder. Mortality has not been associated with this form of therapy. The morbidity associated with intracavitary irradiation consists of mild to severe radiation cystitis and we report 2 such cases. One patient is from a series of 65 patients with noninvasive bladder tumors treated with intracavitary irradiation at this clinic since 1965. The second patient had noninvasive bladder tumors and was treated with intracavitary irradiation elsewhere. In both patients severe radiation cystitis subsequently developed, requiring simple cystectomy and urinary diversion. Themore » potential for this serious side effect must be considered when choosing a form of therapy for patients with noninvasive papillary transitional cell carcinoma and carcinoma in situ of the bladder.« less
Breath Alkane as an index of severity for oral submucous fibrosis: A new perspective?
Arakeri, Gururaj; Boraks, George; Aljabab, Abdulsalam S; Patil, Shekar Gowda; Merkx, M A W; Brennan, Peter A
2017-01-01
Oral submucous fibrosis (OSMF) is a devastating disease commonly seen in the Asian subcontinent that results in significant functional morbidity for patients and has a high potential for malignant transformation. Over the last three decades, different diagnostic methods have been described to quantify and grade OSMF severity. Some methods have been used with perceived favorable outcomes although recurrence and malignant transformation remains a problem in many cases, and OSMF presents a major therapeutic challenge. We present a simple, noninvasive and less time-consuming diagnostic method which measures the severity of OSMF, helping to predict its malignant transformation and monitoring the effect of medical therapy on this disease. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Nailfold capillaroscopy in children and adolescents with rheumatic diseases].
Petry, Daniela G; Terreri, Maria T; Len, Cláudio A; Hilário, Maria O
2008-01-01
Nailfold capillaroscopy is a simple, noninvasive and inexpensive method which allows a functional and morphological study of the capillary network through direct visualization of the distal row of periungueal capillaries of the fingers. This method has been used as a diagnostic auxiliary in diseases such as scleroderma, dermatomyositis, systemic lupus erythematosus and mixed connective tissue disease. It has also been used to differentiate between active and non active diseases, especially dermatomyositis, and to distinguish between primary and secondary Raynaud's phenomenon. Most reports of nailfold capillaroscopy are qualitative and semi-quantitative. Manuscripts describing quantitative methods (video-capillaroscopy) are scarce, particularly in childhood. The authors did a literature review based on Medline, Lilacs and Pubmed data using the keywords: nailfold capillaroscopy, colagenosis, Raynaud, children and adolescents.
NASA Astrophysics Data System (ADS)
Goldys, Ewa M.; Gosnell, Martin E.; Anwer, Ayad G.; Cassano, Juan C.; Sue, Carolyn M.; Mahbub, Saabah B.; Pernichery, Sandeep M.; Inglis, David W.; Adhikary, Partho P.; Jazayeri, Jalal A.; Cahill, Michael A.; Saad, Sonia; Pollock, Carol; Sutton-Mcdowall, Melanie L.; Thompson, Jeremy G.
2016-03-01
Automated and unbiased methods of non-invasive cell monitoring able to deal with complex biological heterogeneity are fundamentally important for biology and medicine. Label-free cell imaging provides information about endogenous fluorescent metabolites, enzymes and cofactors in cells. However extracting high content information from imaging of native fluorescence has been hitherto impossible. Here, we quantitatively characterise cell populations in different tissue types, live or fixed, by using novel image processing and a simple multispectral upgrade of a wide-field fluorescence microscope. Multispectral intrinsic fluorescence imaging was applied to patient olfactory neurosphere-derived cells, cell model of a human metabolic disease MELAS (mitochondrial myopathy, encephalomyopathy, lactic acidosis, stroke-like syndrome). By using an endogenous source of contrast, subtle metabolic variations have been detected between living cells in their full morphological context which made it possible to distinguish healthy from diseased cells before and after therapy. Cellular maps of native fluorophores, flavins, bound and free NADH and retinoids unveiled subtle metabolic signatures and helped uncover significant cell subpopulations, in particular a subpopulation with compromised mitochondrial function. The versatility of our method is further illustrated by detecting genetic mutations in cancer, non-invasive monitoring of CD90 expression, label-free tracking of stem cell differentiation, identifying stem cell subpopulations with varying functional characteristics, tissue diagnostics in diabetes, and assessing the condition of preimplantation embryos. Our optimal discrimination approach enables statistical hypothesis testing and intuitive visualisations where previously undetectable differences become clearly apparent.
Nanri, Akiko; Nakagawa, Tohru; Kuwahara, Keisuke; Yamamoto, Shuichiro; Honda, Toru; Okazaki, Hiroko; Uehara, Akihiko; Yamamoto, Makoto; Miyamoto, Toshiaki; Kochi, Takeshi; Eguchi, Masafumi; Murakami, Taizo; Shimizu, Chii; Shimizu, Makiko; Tomita, Kentaro; Nagahama, Satsue; Imai, Teppei; Nishihara, Akiko; Sasaki, Naoko; Hori, Ai; Sakamoto, Nobuaki; Nishiura, Chihiro; Totsuzaki, Takafumi; Kato, Noritada; Fukasawa, Kenji; Huanhuan, Hu; Akter, Shamima; Kurotani, Kayo; Kabe, Isamu; Mizoue, Tetsuya; Sone, Tomofumi; Dohi, Seitaro
2015-01-01
Objective Risk models and scores have been developed to predict incidence of type 2 diabetes in Western populations, but their performance may differ when applied to non-Western populations. We developed and validated a risk score for predicting 3-year incidence of type 2 diabetes in a Japanese population. Methods Participants were 37,416 men and women, aged 30 or older, who received periodic health checkup in 2008–2009 in eight companies. Diabetes was defined as fasting plasma glucose (FPG) ≥126 mg/dl, random plasma glucose ≥200 mg/dl, glycated hemoglobin (HbA1c) ≥6.5%, or receiving medical treatment for diabetes. Risk scores on non-invasive and invasive models including FPG and HbA1c were developed using logistic regression in a derivation cohort and validated in the remaining cohort. Results The area under the curve (AUC) for the non-invasive model including age, sex, body mass index, waist circumference, hypertension, and smoking status was 0.717 (95% CI, 0.703–0.731). In the invasive model in which both FPG and HbA1c were added to the non-invasive model, AUC was increased to 0.893 (95% CI, 0.883–0.902). When the risk scores were applied to the validation cohort, AUCs (95% CI) for the non-invasive and invasive model were 0.734 (0.715–0.753) and 0.882 (0.868–0.895), respectively. Participants with a non-invasive score of ≥15 and invasive score of ≥19 were projected to have >20% and >50% risk, respectively, of developing type 2 diabetes within 3 years. Conclusions The simple risk score of the non-invasive model might be useful for predicting incident type 2 diabetes, and its predictive performance may be markedly improved by incorporating FPG and HbA1c. PMID:26558900
Quantitative phase microscopy for cellular dynamics based on transport of intensity equation.
Li, Ying; Di, Jianglei; Ma, Chaojie; Zhang, Jiwei; Zhong, Jinzhan; Wang, Kaiqiang; Xi, Teli; Zhao, Jianlin
2018-01-08
We demonstrate a simple method for quantitative phase imaging of tiny transparent objects such as living cells based on the transport of intensity equation. The experiments are performed using an inverted bright field microscope upgraded with a flipping imaging module, which enables to simultaneously create two laterally separated images with unequal defocus distances. This add-on module does not include any lenses or gratings and is cost-effective and easy-to-alignment. The validity of this method is confirmed by the measurement of microlens array and human osteoblastic cells in culture, indicating its potential in the applications of dynamically measuring living cells and other transparent specimens in a quantitative, non-invasive and label-free manner.
Nelson, Jonathan M.; Kinzel, Paul J.; McDonald, Richard R.; Schmeeckle, Mark
2016-01-01
Recently developed optical and videographic methods for measuring water-surface properties in a noninvasive manner hold great promise for extracting river hydraulic and bathymetric information. This paper describes such a technique, concentrating on the method of infrared videog- raphy for measuring surface velocities and both acoustic (laboratory-based) and laser-scanning (field-based) techniques for measuring water-surface elevations. In ideal laboratory situations with simple flows, appropriate spatial and temporal averaging results in accurate water-surface elevations and water-surface velocities. In test cases, this accuracy is sufficient to allow direct inversion of the governing equations of motion to produce estimates of depth and discharge. Unlike other optical techniques for determining local depth that rely on transmissivity of the water column (bathymetric lidar, multi/hyperspectral correlation), this method uses only water-surface information, so even deep and/or turbid flows can be investigated. However, significant errors arise in areas of nonhydrostatic spatial accelerations, such as those associated with flow over bedforms or other relatively steep obstacles. Using laboratory measurements for test cases, the cause of these errors is examined and both a simple semi-empirical method and computational results are presented that can potentially reduce bathymetric inversion errors.
Silicon nanowires: where mechanics and optics meet at the nanoscale.
Ramos, Daniel; Gil-Santos, Eduardo; Malvar, Oscar; Llorens, Jose M; Pini, Valerio; San Paulo, Alvaro; Calleja, Montserrat; Tamayo, Javier
2013-12-06
Mechanical transducers based on nanowires promise revolutionary advances in biological sensing and force microscopy/spectroscopy. A crucial step is the development of simple and non-invasive techniques able to detect displacements with subpicometer sensitivity per unit bandwidth. Here, we design suspended tapered silicon nanowires supporting a range of optical resonances that confine and efficiently scatter light in the visible range. Then, we develop an optical method for efficiently coupling the evanescent field to the regular interference pattern generated by an incoming laser beam and the reflected beam from the substrate underneath the nanowire. This optomechanical coupling is here applied to measure the displacement of 50 nm wide nanowires with sensitivity on the verge of 1 fm/Hz(1/2) at room temperature with a simple laser interferometry set-up. This method opens the door to the measurement of the Brownian motion of ultrashort nanowires for the detection of single biomolecular recognition events in liquids, and single molecule spectroscopy in vacuum.
A simple method for imaging axonal transport in aging neurons using the adult Drosophila wing.
Vagnoni, Alessio; Bullock, Simon L
2016-09-01
There is growing interest in the link between axonal cargo transport and age-associated neuronal dysfunction. The study of axonal transport in neurons of adult animals requires intravital or ex vivo imaging approaches, which are laborious and expensive in vertebrate models. We describe simple, noninvasive procedures for imaging cargo motility within axons using sensory neurons of the translucent Drosophila wing. A key aspect is a method for mounting the intact fly that allows detailed imaging of transport in wing neurons. Coupled with existing genetic tools in Drosophila, this is a tractable system for studying axonal transport over the life span of an animal and thus for characterization of the relationship between cargo dynamics, neuronal aging and disease. Preparation of a sample for imaging takes ∼5 min, with transport typically filmed for 2-3 min per wing. We also document procedures for the quantification of transport parameters from the acquired images and describe how the protocol can be adapted to study other cell biological processes in aging neurons.
Biosensors for Non-Invasive Detection of Celiac Disease Biomarkers in Body Fluids.
Pasinszki, Tibor; Krebsz, Melinda
2018-06-16
Celiac disease is a chronic gluten-initiated autoimmune disorder that predominantly damages the mucosa of the small intestine in genetically-susceptible individuals. It affects a large and increasing number of the world’s population. The diagnosis of this disease and monitoring the response of patients to the therapy, which is currently a life-long gluten-free diet, require the application of reliable, rapid, sensitive, selective, simple, and cost-effective analytical tools. Celiac disease biomarker detection in full blood, serum, or plasma offers a non-invasive way to do this and is well-suited to being the first step of diagnosis. Biosensors provide a novel and alternative way to perform conventional techniques in biomarker sensing, in which electrode material and architecture play important roles in achieving sensitive, selective, and stable detection. There are many opportunities to build and modify biosensor platforms using various materials and detection methods, and the aim of the present review is to summarize developments in this field.
Thermal effusivity: a promising imaging biomarker to predict radiation-induced skin injuries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, J. C. H.; Templeton, A.; Yao, R.
An effective screening technology is needed to triage individuals at the time of radiation incidents involving a large population. Three-dimensional thermal tomography is a relatively new development in active thermal imaging technology that produces cross-sectional images based on the subject's ability to transfer heat thermal effusivity at the voxel level. This noninvasive imaging modality has been used successfully in nondestructive examination of complex materials; also it has been shown to predict the severity of radiation-induced skin injuries several days before the manifestation of severe moist desquamations or blister formation symptoms in mice at 40 Gy. If these results are confirmedmore » at lower dose levels in human subjects, a thermal tomography imaging device may be an ideal screening tool in radiation emergencies. This imaging method is non-invasive, relatively simple, easily adaptable for field use, and when properly deployed, it will enhance public emergency preparedness for incidents involving unexpected radiation exposure.« less
Vargas, E; Ruiz, M A; Campuzano, S; Reviejo, A J; Pingarrón, J M
2016-03-31
A non-destructive, rapid and simple to use sensing method for direct determination of glucose in non-processed fruits is described. The strategy involved on-line microdialysis sampling coupled with a continuous flow system with amperometric detection at an enzymatic biosensor. Apart from direct determination of glucose in fruit juices and blended fruits, this work describes for the first time the successful application of an enzymatic biosensor-based electrochemical approach to the non-invasive determination of glucose in raw fruits. The methodology correlates, through previous calibration set-up, the amperometric signal generated from glucose in non-processed fruits with its content in % (w/w). The comparison of the obtained results using the proposed approach in different fruits with those provided by other method involving the same commercial biosensor as amperometric detector in stirred solutions pointed out that there were no significant differences. Moreover, in comparison with other available methodologies, this microdialysis-coupled continuous flow system amperometric biosensor-based procedure features straightforward sample preparation, low cost, reduced assay time (sampling rate of 7 h(-1)) and ease of automation. Copyright © 2016 Elsevier B.V. All rights reserved.
Parameswaran, Krishnan R; Rosen, David I; Allen, Mark G; Ganz, Alan M; Risby, Terence H
2009-02-01
Cavity-enhanced tunable diode laser absorption spectroscopy is an attractive method for measuring small concentrations of gaseous species. Ethane is a breath biomarker of lipid peroxidation initiated by reactive oxygen species. A noninvasive means of quickly quantifying oxidative stress status has the potential for broad clinical application. We present a simple, compact system using off-axis integrated cavity output spectroscopy with an interband cascade laser and demonstrate its use in real-time measurements of breath ethane. We demonstrate a detection sensitivity of 0.48 ppb/Hz(1/2).
Laparoscopic management of cystic disease of the liver.
Albrink, M H; McAllister, E W; Rosemurgy, A S; Karl, R C; Carey, L C
1994-04-01
Laparoscopic surgical procedures are increasing in scope and in variety. The benefits of decreased wound morbidity and pain have been well documented for multiple procedures that have traditionally required laparotomy. Although there are few controlled studies to document them, these benefits may be evident from simple clinical observation. Cystic disease of the liver is a condition that is treated largely for symptomatic reasons. The so-called noninvasive or radiographic guided methods of treatment for cystic disease of the liver are fraught with high recurrence rates. We present four cases of cystic disease of the liver treated laparoscopically, followed with pertinent discussion.
[Color Doppler ultrasonography--a new imaging procedure in maxillofacial surgery].
Reinert, S; Lentrodt, J
1991-01-01
Colour Doppler ultrasonography shows blood flow in real time and colour by combining the features of real time B mode ultrasound and Doppler. At each point in the image the returning signal is interrogated for both amplitude and frequency information. The resulting image shows all non-moving structures in shades of gray and moving structures in shades of red or blue depending on direction and velocity. The technique of colour Doppler ultrasonography and our experiences in 63 examinations are described. The clinical application of this new simple non-invasive method in maxillo-facial surgery is discussed.
Davoudi, Arash; Seighalani, Ramin; Aleyasin, Seyed Ahmad; Tarang, Alireza; Salehi, Abdolreza Salehi; Tahmoressi, Farideh
2012-04-01
In order to establish a reliable non-invasive method for sex determination in a bovine fetus in a routine setting, the possibility of identifying specific sequence in the fetal X and Y-chromosomes has been evaluated in maternal plasma using conventional multiplex polymerase chain reaction (PCR) analysis. The aim of this study was to provide a rapid and reliable method for sexing bovine fetuses. In this experimental study, peripheral blood samples were taken from 38 pregnant heifers with 8 to 38 weeks of gestation. DNA template was extracted by phenol-chloroform method from 350 µl maternal plasma. Two primer pairs for bovine amelogenin gene (bAML) and BC1.2 were used to amplify fragments from X and Y chromosomes. A multiplex PCR reaction has been optimized for amplification of 467 bp and 341 bp fragments from X and Y bAML gene and a 190 bp fragment from BC1.2 related to Y chromosome. The 467 bp fragment was observed in all 38 samples. Both 341 and 190 bp fragments were detected only in 24 plasma samples from male calves. The sensitivity and specificity of test were 100% with no false negative or false positive results. The results showed that phenol-chloroform method is a simple and suitable method for isolation of fetal DNA in maternal plasma. The multiplex PCR method is an available non-invasive approach which is cost efficient and reliable for sexing bovine fetuses.
Development of a Low-Cost, Noninvasive, Portable Visual Speech Recognition Program.
Kohlberg, Gavriel D; Gal, Ya'akov Kobi; Lalwani, Anil K
2016-09-01
Loss of speech following tracheostomy and laryngectomy severely limits communication to simple gestures and facial expressions that are largely ineffective. To facilitate communication in these patients, we seek to develop a low-cost, noninvasive, portable, and simple visual speech recognition program (VSRP) to convert articulatory facial movements into speech. A Microsoft Kinect-based VSRP was developed to capture spatial coordinates of lip movements and translate them into speech. The articulatory speech movements associated with 12 sentences were used to train an artificial neural network classifier. The accuracy of the classifier was then evaluated on a separate, previously unseen set of articulatory speech movements. The VSRP was successfully implemented and tested in 5 subjects. It achieved an accuracy rate of 77.2% (65.0%-87.6% for the 5 speakers) on a 12-sentence data set. The mean time to classify an individual sentence was 2.03 milliseconds (1.91-2.16). We have demonstrated the feasibility of a low-cost, noninvasive, portable VSRP based on Kinect to accurately predict speech from articulation movements in clinically trivial time. This VSRP could be used as a novel communication device for aphonic patients. © The Author(s) 2016.
Dyeing Insects for Behavioral Assays: the Mating Behavior of Anesthetized Drosophila
Verspoor, Rudi L.; Heys, Chloe; Price, Thomas A. R.
2015-01-01
Mating experiments using Drosophila have contributed greatly to the understanding of sexual selection and behavior. Experiments often require simple, easy and cheap methods to distinguish between individuals in a trial. A standard technique for this is CO2 anaesthesia and then labelling or wing clipping each fly. However, this is invasive and has been shown to affect behavior. Other techniques have used coloration to identify flies. This article presents a simple and non-invasive method for labelling Drosophila that allows them to be individually identified within experiments, using food coloring. This method is used in trials where two males compete to mate with a female. Dyeing allowed quick and easy identification. There was, however, some difference in the strength of the coloration across the three species tested. Data is presented showing the dye has a lower impact on mating behavior than CO2 in Drosophila melanogaster. The impact of CO2 anaesthesia is shown to depend on the species of Drosophila, with D. pseudoobscura and D. subobscura showing no impact, whereas D. melanogaster males had reduced mating success. The dye method presented is applicable to a wide range of experimental designs. PMID:25938821
A noninvasive method of examination of the hemostasis system.
Kuznik, B I; Fine, I W; Kaminsky, A V
2011-09-01
We propose a noninvasive method of in vivo examination the hemostasis system based on speckle pattern analysis of coherent light scattering from the skin. We compared the results of measuring basic blood coagulation parameters by conventional invasive and noninvasive methods. A strict correlation was found between the results of measurement of soluble fibrin monomer complexes, international normalized ratio (INR), prothrombin index, and protein C content. The noninvasive method of examination of the hemostatic system enable rough evaluation of the intensity of the intravascular coagulation and correction of the dose of indirect anticoagulants maintaining desired values of INR or prothrombin index.
NASA Astrophysics Data System (ADS)
Herrera, María. S.; Monti Hughes, Andrea; Salva, Natalia; Padra, Claudio; Schwint, Amanda; Santa Cruz, Gustavo A.
2017-05-01
Biomedical infrared thermography, a non-invasive and functional imaging method, provides information on the normal and abnormal status and response of tissues in terms of spatial and temporal variations in body infrared radiance. It is especially attractive in cancer research due to the hypervascular and hypermetabolic activity of solid tumors. Moreover, healthy tissues like skin or mucosa exposed to radiation can be examined since inflammation, changes in water content, exudation, desquamation, erosion and necrosis, between others, are factors that modify their thermal properties. In this work we performed Dynamic Infrared Imaging (DIRI) to contribute to the understanding and evaluation of normal tissue, tumor and precancerous tissue response and radiotoxicity in an in vivo model, the hamster cheek pouch, exposed to Boron Neutron Capture Therapy. In this study, we particularly focused on the observation of temperature changes under forced transient conditions associated with mass moisture transfer in the tissue-air interface, in each tissue with or without treatment. We proposed a simple mathematical procedure that considerers the heat transfer from tissue to ambient through convection and evaporation to model the transient (exponential decay o recover) thermal study. The data was fitted to determined the characteristic decay and recovery time constants of the temperature as a function of time. Also this model allowed to explore the mass flux of moisture, as a degree of evaporation occurring on the tissue surface. Tissue thermal responses under provocation tests could be used as a non-invasive method to characterize tissue physiology.
FDTD analysis of a noninvasive hyperthermia system for brain tumors
2012-01-01
Background Hyperthermia is considered one of the new therapeutic modalities for cancer treatment and is based on the difference in thermal sensitivity between healthy tissues and tumors. During hyperthermia treatment, the temperature of the tumor is raised to 40–45°C for a definite period resulting in the destruction of cancer cells. This paper investigates design, modeling and simulation of a new non-invasive hyperthermia applicator system capable of effectively heating deep seated as well as superficial brain tumors using inexpensive, simple, and easy to fabricate components without harming surrounding healthy brain tissues. Methods The proposed hyperthermia applicator system is composed of an air filled partial half ellipsoidal chamber, a patch antenna, and a head model with an embedded tumor at an arbitrary location. The irradiating antenna is placed at one of the foci of the hyperthermia chamber while the center of the brain tumor is placed at the other focus. The finite difference time domain (FDTD) method is used to compute both the SAR patterns and the temperature distribution in three different head models due to two different patch antennas at a frequency of 915 MHz. Results The obtained results suggest that by using the proposed noninvasive hyperthermia system it is feasible to achieve sufficient and focused energy deposition and temperature rise to therapeutic values in deep seated as well as superficial brain tumors without harming surrounding healthy tissue. Conclusions The proposed noninvasive hyperthermia system proved suitable for raising the temperature in tumors embedded in the brain to therapeutic values by carefully selecting the systems components. The operator of the system only needs to place the center of the brain tumor at a pre-specified location and excite the antenna at a single frequency of 915 MHz. Our study may provide a basis for a clinical applicator prototype capable of heating brain tumors. PMID:22891953
A cost-efficient frequency-domain photoacoustic imaging system
LeBoulluec, Peter; Liu, Hanli; Yuan, Baohong
2013-01-01
Photoacoustic (PA) imaging techniques have recently attracted much attention and can be used for noninvasive imaging of biological tissues. Most PA imaging systems in research laboratories use the time domain method with expensive nanosecond pulsed lasers that are not affordable for most educational laboratories. Using an intensity modulated light source to excite PA signals is an alternative technique, known as the frequency domain method, with a much lower cost. In this paper, we describe a simple frequency domain PA system and demonstrate its imaging capability. The system provides opportunities not only to observe PA signals in tissue phantoms, but also to acquire hands-on skills in PA signal detection. It also provides opportunities to explore the underlying mechanisms of the PA effect. PMID:24659823
A cost-efficient frequency-domain photoacoustic imaging system.
Leboulluec, Peter; Liu, Hanli; Yuan, Baohong
2013-09-01
Photoacoustic (PA) imaging techniques have recently attracted much attention and can be used for noninvasive imaging of biological tissues. Most PA imaging systems in research laboratories use the time domain method with expensive nanosecond pulsed lasers that are not affordable for most educational laboratories. Using an intensity modulated light source to excite PA signals is an alternative technique, known as the frequency domain method, with a much lower cost. In this paper, we describe a simple frequency domain PA system and demonstrate its imaging capability. The system provides opportunities not only to observe PA signals in tissue phantoms, but also to acquire hands-on skills in PA signal detection. It also provides opportunities to explore the underlying mechanisms of the PA effect.
A cell-free assay to determine the stoichiometry of plasma membrane proteins.
Trigo, Cesar; Vivar, Juan P; Gonzalez, Carlos B; Brauchi, Sebastian
2013-04-01
Plasma membrane receptors, transporters, and ion channel molecules are often found as oligomeric structures that participate in signaling cascades essential for cell survival. Different states of protein oligomerization may play a role in functional control and allosteric regulation. Stochastic GFP-photobleaching (SGP) has emerged as an affordable and simple method to determine the stoichiometry of proteins at the plasma membrane. This non-invasive optical approach can be useful for total internal reflection of fluorescence microscopy (TIRFM), where signal-to-noise ratio is very high at the plasma membrane. Here, we report an alternative methodology implemented on a standard laser scanning confocal microscope (LSCM). The simplicity of our method will allow for its implementation in any epifluorescence microscope of choice.
Ejazi, Sarfaraz Ahmad; Bhattacharya, Pradyot; Bakhteyar, Md. Asjad Karim; Mumtaz, Aquil Ahmad; Pandey, Krishna; Das, Vidya Nand Ravi; Das, Pradeep; Rahaman, Mehebubar; Goswami, Rama Prosad; Ali, Nahid
2016-01-01
Background Visceral Leishmaniasis (VL), a severe parasitic disease, could be fatal if diagnosis and treatment is delayed. Post kala-azar dermal leishmaniasis (PKDL), a skin related outcome, is a potential reservoir for the spread of VL. Diagnostic tests available for VL such as tissue aspiration are invasive and painful although they are capable of evaluating the treatment response. Serological tests although less invasive than tissue aspiration are incompetent to assess cure. Parasitological examination of slit-skin smear along with the clinical symptoms is routinely used for diagnosis of PKDL. Therefore, a noninvasive test with acceptable sensitivity and competency, additionally, to decide cure would be an asset in disease management and control. Methodology/principal findings We describe here, the development of antibody-capture ELISA and field adaptable dipstick test as noninvasive diagnostic tools for VL and PKDL and as a test of cure in VL treatment. Sensitivity and specificity of urine-ELISA were 97.94% (95/97) and 100% (75/75) respectively, for VL. Importantly, dipstick test demonstrated 100% sensitivity (97/97) and specificity (75/75) in VL diagnosis. Degree of agreement of the two methods with tissue aspiration was 98.83% (κ = 0.97) and 100% (κ = 1), for ELISA and dipstick test, respectively. Both the tests had 100% positivity for PKDL (14/14) cases. ELISA and dipstick test illustrated treatment efficacy in about 90% (16/18) VL cases when eventually turned negative after six months of treatment. Conclusions/significance ELISA and dipstick test found immensely effective for diagnosis of VL and PKDL through urine samples thus, may substitute the existing invasive diagnostics. Utility of these tests as indirect methods of monitoring parasite clearance can define infected versus cured. Urine-based dipstick test is simple, sensitive and above all noninvasive method that may help not only in active VL case detection but also to ascertain treatment response. It can therefore, be deployed widely for interventions in disease management of VL particularly in poor resource outskirts. PMID:27741241
Advanced imaging of the macrostructure and microstructure of bone
NASA Technical Reports Server (NTRS)
Genant, H. K.; Gordon, C.; Jiang, Y.; Link, T. M.; Hans, D.; Majumdar, S.; Lang, T. F.
2000-01-01
Noninvasive and/or nondestructive techniques are capable of providing more macro- or microstructural information about bone than standard bone densitometry. Although the latter provides important information about osteoporotic fracture risk, numerous studies indicate that bone strength is only partially explained by bone mineral density. Quantitative assessment of macro- and microstructural features may improve our ability to estimate bone strength. The methods available for quantitatively assessing macrostructure include (besides conventional radiographs) quantitative computed tomography (QCT) and volumetric quantitative computed tomography (vQCT). Methods for assessing microstructure of trabecular bone noninvasively and/or nondestructively include high-resolution computed tomography (hrCT), micro-computed tomography (muCT), high-resolution magnetic resonance (hrMR), and micromagnetic resonance (muMR). vQCT, hrCT and hrMR are generally applicable in vivo; muCT and muMR are principally applicable in vitro. Although considerable progress has been made in the noninvasive and/or nondestructive imaging of the macro- and microstructure of bone, considerable challenges and dilemmas remain. From a technical perspective, the balance between spatial resolution versus sampling size, or between signal-to-noise versus radiation dose or acquisition time, needs further consideration, as do the trade-offs between the complexity and expense of equipment and the availability and accessibility of the methods. The relative merits of in vitro imaging and its ultrahigh resolution but invasiveness versus those of in vivo imaging and its modest resolution but noninvasiveness also deserve careful attention. From a clinical perspective, the challenges for bone imaging include balancing the relative advantages of simple bone densitometry against the more complex architectural features of bone or, similarly, the deeper research requirements against the broader clinical needs. The considerable potential biological differences between the peripheral appendicular skeleton and the central axial skeleton have to be addressed further. Finally, the relative merits of these sophisticated imaging techniques have to be weighed with respect to their applications as diagnostic procedures requiring high accuracy or reliability on one hand and their monitoring applications requiring high precision or reproducibility on the other. Copyright 2000 S. Karger AG, Basel.
Wang, Qihui; Gao, Pan; Cheng, Fei; Wang, Xiaoyi; Duan, Yixiang
2014-02-01
This study aimed to set-up an ultra performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS) method for the determination of salivary L-phenylalanine and L-leucine for early diagnosis of oral squamous cell carcinoma (OSCC). In addition, the diagnostic accuracy for both biomarkers was established by using receiver operating characteristic (ROC) analysis. Mean recoveries of l-phenylalanine and L-leucine ranged from 88.9 to 108.6% were obtained. Intra- and inter-day precision for both amino acids was less than 7%, with acceptable accuracy. Linear regression coefficients of both biomarkers were greater than 0.99. The diagnostic accuracy for both biomarkers was established by analyzing 60 samples from apparently healthy individuals and 30 samples from OSCC patients. Both potential biomarkers demonstrated significant differences in concentrations in distinguishing OSCC from control (P<0.05). As a single biomarker, L-leucine might have better predictive power in OSCC with T1-2 (early stage of OSCC including stage I and II), and L-phenylalanine might be used for screening and diagnosis of OSCC with T3-4 (advanced stage of OSCC including stage III and IV). The combination of L-phenylalanine and L-leucine will improve the sensitivity (92.3%) and specificity (91.7%) for early diagnosis of OSCC. The possibility of salivary metabolite biomarkers for OSCC diagnosis is successfully demonstrated in this study. This developed method shows advantages with non-invasive, simple, reliable, and also provides lower detection limits and excellent precision and accuracy. These non-invasive salivary biomarkers may lead to a simple clinical tool for the early diagnosis of OSCC. © 2013 Published by Elsevier B.V.
Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji
2008-10-01
Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.
Analysis for drugs in saliva and breath
DOT National Transportation Integrated Search
1981-09-25
Collection devices for saliva and breath that involved non-invasive techniques for sample collection were evaluated. Having subjects simply spit into a specially prepared glass vial was found to be an efficient, inexpensive and simple way to collect ...
Analysis for drug in saliva and breath
DOT National Transportation Integrated Search
1981-09-25
Collection devices for saliva and breath that involved non-invasive : techniques for sample collection were evaluated. Having subjects simply : spit into a specially prepared glass vial was found to be an efficient, : inexpensive and simple way to co...
Surface electromyography as a screening method for evaluation of dysphagia and odynophagia
Vaiman, Michael; Eviatar, Ephraim
2009-01-01
Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090
Simple noninvasive measurement of skin autofluorescence.
Meerwaldt, Robbert; Links, Thera; Graaff, Reindert; Thorpe, Suzannne R; Baynes, John W; Hartog, Jasper; Gans, Reinold; Smit, Andries
2005-06-01
Accumulation of advanced glycation end products (AGEs) is thought to play a role in the pathogenesis of chronic complications of diabetes mellitus and renal failure. Several studies indicate that AGE accumulation in tissue may reflect the cumulative effect of hyperglycemia and oxidative stress over many years. Simple quantitation of AGE accumulation in tissue could provide a tool for assessing the risk of long-term complications. Because several AGEs exhibit autofluorescence, we developed a noninvasive autofluorescence reader (AFR). Skin autofluorescence measured with the AFR correlates with collagen-linked fluorescence and specific skin AGE levels from skin biopsy samples. Furthermore, skin autofluorescence correlates with long-term glycemic control and renal function, and preliminary results show correlations with the presence of long-term complications in diabetes. The AFR may be useful as a clinical tool for rapid assessment of risk for AGE-related long-term complications in diabetes and in other conditions associated with AGE accumulation.
Bayrakli, Ismail; Öztürk, Önder; Akman, Hatice
2016-12-01
The objective of the present study was to investigate whether analysis of carbon dioxide, acetone and/or butanol present in human breath can be used as a simple and noninvasive diagnosis method for obstructive sleep apnea syndrome (OSAS). For this purpose, overnight changes in the concentrations of these breath molecules were measured before and after sleep in 10 patients who underwent polysomnography and were diagnosed with OSAS, and were compared with the levels of these biomarkers determined after sleep in 10 healthy subjects. The concentrations of exhaled carbon dioxide were measured using external cavity laser-based off-axis cavity enhanced absorption spectroscopy, whereas the levels of exhaled acetone and butanol were determined using thermal desorption gas chromatography mass spectrometry. We observed no significant changes in the levels of exhaled acetone and carbon dioxide in OSAS patients after sleep compared with pre-sleep values and compared with those in healthy control subjects. However, for the first time, to our knowledge, analyses of expired air showed an increased concentration of butanol after sleep compared with that before sleep and compared with that in healthy subjects. These results suggest that butanol can be established as a potential biomarker to enable the convenient and noninvasive diagnosis of OSAS in the future. Copyright © 2016 John Wiley & Sons, Ltd.
Multi-atlas segmentation enables robust multi-contrast MRI spleen segmentation for splenomegaly
NASA Astrophysics Data System (ADS)
Huo, Yuankai; Liu, Jiaqi; Xu, Zhoubing; Harrigan, Robert L.; Assad, Albert; Abramson, Richard G.; Landman, Bennett A.
2017-02-01
Non-invasive spleen volume estimation is essential in detecting splenomegaly. Magnetic resonance imaging (MRI) has been used to facilitate splenomegaly diagnosis in vivo. However, achieving accurate spleen volume estimation from MR images is challenging given the great inter-subject variance of human abdomens and wide variety of clinical images/modalities. Multi-atlas segmentation has been shown to be a promising approach to handle heterogeneous data and difficult anatomical scenarios. In this paper, we propose to use multi-atlas segmentation frameworks for MRI spleen segmentation for splenomegaly. To the best of our knowledge, this is the first work that integrates multi-atlas segmentation for splenomegaly as seen on MRI. To address the particular concerns of spleen MRI, automated and novel semi-automated atlas selection approaches are introduced. The automated approach interactively selects a subset of atlases using selective and iterative method for performance level estimation (SIMPLE) approach. To further control the outliers, semi-automated craniocaudal length based SIMPLE atlas selection (L-SIMPLE) is proposed to introduce a spatial prior in a fashion to guide the iterative atlas selection. A dataset from a clinical trial containing 55 MRI volumes (28 T1 weighted and 27 T2 weighted) was used to evaluate different methods. Both automated and semi-automated methods achieved median DSC > 0.9. The outliers were alleviated by the L-SIMPLE (≍1 min manual efforts per scan), which achieved 0.9713 Pearson correlation compared with the manual segmentation. The results demonstrated that the multi-atlas segmentation is able to achieve accurate spleen segmentation from the multi-contrast splenomegaly MRI scans.
Multi-atlas Segmentation Enables Robust Multi-contrast MRI Spleen Segmentation for Splenomegaly.
Huo, Yuankai; Liu, Jiaqi; Xu, Zhoubing; Harrigan, Robert L; Assad, Albert; Abramson, Richard G; Landman, Bennett A
2017-02-11
Non-invasive spleen volume estimation is essential in detecting splenomegaly. Magnetic resonance imaging (MRI) has been used to facilitate splenomegaly diagnosis in vivo. However, achieving accurate spleen volume estimation from MR images is challenging given the great inter-subject variance of human abdomens and wide variety of clinical images/modalities. Multi-atlas segmentation has been shown to be a promising approach to handle heterogeneous data and difficult anatomical scenarios. In this paper, we propose to use multi-atlas segmentation frameworks for MRI spleen segmentation for splenomegaly. To the best of our knowledge, this is the first work that integrates multi-atlas segmentation for splenomegaly as seen on MRI. To address the particular concerns of spleen MRI, automated and novel semi-automated atlas selection approaches are introduced. The automated approach interactively selects a subset of atlases using selective and iterative method for performance level estimation (SIMPLE) approach. To further control the outliers, semi-automated craniocaudal length based SIMPLE atlas selection (L-SIMPLE) is proposed to introduce a spatial prior in a fashion to guide the iterative atlas selection. A dataset from a clinical trial containing 55 MRI volumes (28 T1 weighted and 27 T2 weighted) was used to evaluate different methods. Both automated and semi-automated methods achieved median DSC > 0.9. The outliers were alleviated by the L-SIMPLE (≈1 min manual efforts per scan), which achieved 0.9713 Pearson correlation compared with the manual segmentation. The results demonstrated that the multi-atlas segmentation is able to achieve accurate spleen segmentation from the multi-contrast splenomegaly MRI scans.
El Serafy, Magdy Amin; Kassem, Abdel Meguid; Omar, Heba; Mahfouz, Mohammad Shaaban; El Said El Raziky, Maissa
2017-06-01
Hepatitis C virus (HCV) accounts for a sizable proportion of chronic liver disease cases and represents the most common indication for liver transplantation. Precise diagnosis of hepatic fibrosis stage is considered a funnel-neck in proper management and follow-up of HCV-infected patients. Given the possible complications of liver biopsy, a non-invasive method for assessing hepatic fibrosis is needed. This study aimed to evaluate the diagnostic accuracy of APRI and hyaluronic acid as non-invasive diagnostic assessment tools for post HCV liver fibrosis. Systematic literature searching identified studies performed on Egyptian territory to evaluate APRI and hyaluronic acid as non-invasive tests of fibrosis and using liver biopsy as the reference standard. Meta-analysis was performed for areas with an adequate number of publications. Validation of meta- analysis on APRI was done on a subset of 150 treatment-naïve post-hepatitis C patients. Both APRI and hyaluronic acid have superior predictive power for hepatic cirrhosis (F4) than for significant fibrosis (F2-F3). The pooled estimate for sensitivities and specificities of APRI and hyaluronic acid to diagnose F4 were (84% and 82%) and (83% and 89%) respectively. In the subgroup of treatment naïve post-hepatitis C patients, APRI had higher diagnostic performance to diagnose liver cirrhosis with 93.8% sensitivity and 72.4% specificity (AUC; 0.908, 95%CI; 0.851-0.965, p-value; <0.001) compared to its accuracy to diagnose significant hepatic fibrosis with 65.1% sensitivity and 77.8% (AUC; 0.685, 95% CI; 0.59-0.78, p-value; 0.001). APRI score and hyaluronic acid levels are simple and reliable non-invasive markers to detect advanced fibrosis among post-hepatitis C patients. Copyright © 2017 Pan-Arab Association of Gastroenterology. Published by Elsevier B.V. All rights reserved.
Riera-Borrull, Marta; Rodríguez-Gallego, Esther; Hernández-Aguilera, Anna; Luciano, Fedra; Ras, Rosa; Cuyàs, Elisabet; Camps, Jordi; Segura-Carretero, Antonio; Menendez, Javier A; Joven, Jorge; Fernández-Arroyo, Salvador
2016-01-01
Abnormalities in mitochondrial metabolism and regulation of energy balance contribute to human diseases. The consequences of high fat and other nutrient intake, and the resulting acquired mitochondrial dysfunction, are essential to fully understand common disorders, including obesity, cancer, and atherosclerosis. To simultaneously and noninvasively measure and quantify indirect markers of mitochondrial function, we have developed a method based on gas chromatography coupled to quadrupole-time of flight mass spectrometry and an electron ionization interface, and validated the system using plasma from patients with peripheral artery disease, human cancer cells, and mouse tissues. This approach was used to increase sensibility in the measurement of a wide dynamic range and chemical diversity of multiple intermediate metabolites used in energy metabolism. We demonstrate that our targeted metabolomics method allows for quick and accurate identification and quantification of molecules, including the measurement of small yet significant biological changes in experimental samples. The apparently low process variability required for its performance in plasma, cell lysates, and tissues allowed a rapid identification of correlations between interconnected pathways. Our results suggest that delineating the process of energy generation by targeted metabolomics can be a valid surrogate for predicting mitochondrial dysfunction in biological samples. Importantly, when used in plasma, targeted metabolomics should be viewed as a robust and noninvasive source of biomarkers in specific pathophysiological scenarios.
NASA Astrophysics Data System (ADS)
Riera-Borrull, Marta; Rodríguez-Gallego, Esther; Hernández-Aguilera, Anna; Luciano, Fedra; Ras, Rosa; Cuyàs, Elisabet; Camps, Jordi; Segura-Carretero, Antonio; Menendez, Javier A.; Joven, Jorge; Fernández-Arroyo, Salvador
2016-01-01
Abnormalities in mitochondrial metabolism and regulation of energy balance contribute to human diseases. The consequences of high fat and other nutrient intake, and the resulting acquired mitochondrial dysfunction, are essential to fully understand common disorders, including obesity, cancer, and atherosclerosis. To simultaneously and noninvasively measure and quantify indirect markers of mitochondrial function, we have developed a method based on gas chromatography coupled to quadrupole-time of flight mass spectrometry and an electron ionization interface, and validated the system using plasma from patients with peripheral artery disease, human cancer cells, and mouse tissues. This approach was used to increase sensibility in the measurement of a wide dynamic range and chemical diversity of multiple intermediate metabolites used in energy metabolism. We demonstrate that our targeted metabolomics method allows for quick and accurate identification and quantification of molecules, including the measurement of small yet significant biological changes in experimental samples. The apparently low process variability required for its performance in plasma, cell lysates, and tissues allowed a rapid identification of correlations between interconnected pathways. Our results suggest that delineating the process of energy generation by targeted metabolomics can be a valid surrogate for predicting mitochondrial dysfunction in biological samples. Importantly, when used in plasma, targeted metabolomics should be viewed as a robust and noninvasive source of biomarkers in specific pathophysiological scenarios.
A comparison of quantitative methods for clinical imaging with hyperpolarized (13)C-pyruvate.
Daniels, Charlie J; McLean, Mary A; Schulte, Rolf F; Robb, Fraser J; Gill, Andrew B; McGlashan, Nicholas; Graves, Martin J; Schwaiger, Markus; Lomas, David J; Brindle, Kevin M; Gallagher, Ferdia A
2016-04-01
Dissolution dynamic nuclear polarization (DNP) enables the metabolism of hyperpolarized (13)C-labelled molecules, such as the conversion of [1-(13)C]pyruvate to [1-(13)C]lactate, to be dynamically and non-invasively imaged in tissue. Imaging of this exchange reaction in animal models has been shown to detect early treatment response and correlate with tumour grade. The first human DNP study has recently been completed, and, for widespread clinical translation, simple and reliable methods are necessary to accurately probe the reaction in patients. However, there is currently no consensus on the most appropriate method to quantify this exchange reaction. In this study, an in vitro system was used to compare several kinetic models, as well as simple model-free methods. Experiments were performed using a clinical hyperpolarizer, a human 3 T MR system, and spectroscopic imaging sequences. The quantitative methods were compared in vivo by using subcutaneous breast tumours in rats to examine the effect of pyruvate inflow. The two-way kinetic model was the most accurate method for characterizing the exchange reaction in vitro, and the incorporation of a Heaviside step inflow profile was best able to describe the in vivo data. The lactate time-to-peak and the lactate-to-pyruvate area under the curve ratio were simple model-free approaches that accurately represented the full reaction, with the time-to-peak method performing indistinguishably from the best kinetic model. Finally, extracting data from a single pixel was a robust and reliable surrogate of the whole region of interest. This work has identified appropriate quantitative methods for future work in the analysis of human hyperpolarized (13)C data. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
Label-free SPR detection of gluten peptides in urine for non-invasive celiac disease follow-up.
Soler, Maria; Estevez, M-Carmen; Moreno, Maria de Lourdes; Cebolla, Angel; Lechuga, Laura M
2016-05-15
Motivated by the necessity of new and efficient methods for dietary gluten control of celiac patients, we have developed a simple and highly sensitive SPR biosensor for the detection of gluten peptides in urine. The sensing methodology enables rapid and label-free quantification of the gluten immunogenic peptides (GIP) by using G12 mAb. The overall performance of the biosensor has been in-depth optimized and evaluated in terms of sensitivity, selectivity and reproducibility, reaching a limit of detection of 0.33 ng mL(-1). Besides, the robustness and stability of the methodology permit the continuous use of the biosensor for more than 100 cycles with excellent repeatability. Special efforts have been focused on preventing and minimizing possible interferences coming from urine matrix enabling a direct analysis in this fluid without requiring extraction or purification procedures. Our SPR biosensor has proven to detect and identify gluten consumption by evaluating urine samples from healthy and celiac individuals with different dietary gluten conditions. This novel biosensor methodology represents a novel approach to quantify the digested gluten peptides in human urine with outstanding sensitivity in a rapid and non-invasive manner. Our technique should be considered as a promising opportunity to develop Point-of-Care (POC) devices for an efficient, simple and accurate gluten free diet (GFD) monitoring as well as therapy follow-up of celiac disease patients. Copyright © 2015 Elsevier B.V. All rights reserved.
[The application of stereology in radiology imaging and cell biology fields].
Hu, Na; Wang, Yan; Feng, Yuanming; Lin, Wang
2012-08-01
Stereology is an interdisciplinary method for 3D morphological study developed from mathematics and morphology. It is widely used in medical image analysis and cell biology studies. Because of its unbiased, simple, fast, reliable and non-invasive characteristics, stereology has been widely used in biomedical areas for quantitative analysis and statistics, such as histology, pathology and medical imaging. Because the stereological parameters show distinct differences in different pathology, many scholars use stereological methods to do quantitative analysis in their studies in recent years, for example, in the areas of the condition of cancer cells, tumor grade, disease development and the patient's prognosis, etc. This paper describes the stereological concept and estimation methods, also illustrates the applications of stereology in the fields of CT images, MRI images and cell biology, and finally reflects the universality, the superiority and reliability of stereology.
Near-infrared optical imaging of nucleic acid nanocarriers in vivo.
Rome, Claire; Gravier, Julien; Morille, Marie; Divita, Gilles; Bolcato-Bellemin, Anne-Laure; Josserand, Véronique; Coll, Jean-Luc
2013-01-01
Noninvasive, real-time optical imaging methods are well suited to follow the in vivo distribution of nucleic acid nanocarriers, their dissociation, and the resulting gene expression or inhibition. Indeed, most small animal imaging devices perform bioluminescence and fluorescence measurements without moving the animal, allowing a simple, rapid, and cost-effective method of investigation of several parameters at a time, in longitudinal experiments that can last for days or weeks.Here we help the reader in choosing adapted near-infrared (NIR) fluorophores or pairs of fluorophores for Förster resonance energy transfer assays, imaging of reporter genes, as well as nanocarriers for in vivo gene and siRNA delivery. In addition, we present the labeling methods of these macromolecules and of their payload and the protocols to detect them using bioluminescence and NIR fluorescence imaging in mice.
Near-infrared optical imaging of nucleic acid nanocarriers in vivo
Rome, Claire; Gravier, Julien; Morille, Marie; Divita, Gilles; Bolcato-Bellemin, Anne-Laure; Josserand, Véronique; Coll, Jean-Luc
2013-01-01
Summary Non-invasive, real time optical imaging methods are particularly well suited for the in vivo follow up of the distribution of nucleic acids nanocarriers, their dissociation and finally the resulting gene expression or inhibition. Indeed, most small animal imaging devices are performing bioluminescence and fluorescence measurements without moving the animal, allowing a simple, rapid and cost effective method of investigation of several parameters at a time, in longitudinal experiments that can last for days or weeks. Here we propose to help the reader choosing adapted near-infrared (NIR) fluorophores or pairs of fluorophores for FRET assays, reporter genes as well as nanocarriers for in vivo gene and siRNA delivery. In addition, we present the labeling methods of these macromolecules, and of their payload and the protocols to detect them using bioluminescence and NIR fluorescence imaging in mice. PMID:23070763
Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW).
Shi, Jinjie; Ahmed, Daniel; Mao, Xiaole; Lin, Sz-Chin Steven; Lawit, Aitan; Huang, Tony Jun
2009-10-21
Here we present an active patterning technique named "acoustic tweezers" that utilizes standing surface acoustic wave (SSAW) to manipulate and pattern cells and microparticles. This technique is capable of patterning cells and microparticles regardless of shape, size, charge or polarity. Its power intensity, approximately 5x10(5) times lower than that of optical tweezers, compares favorably with those of other active patterning methods. Flow cytometry studies have revealed it to be non-invasive. The aforementioned advantages, along with this technique's simple design and ability to be miniaturized, render the "acoustic tweezers" technique a promising tool for various applications in biology, chemistry, engineering, and materials science.
An analysis of estimation of pulmonary blood flow by the single-breath method
NASA Technical Reports Server (NTRS)
Srinivasan, R.
1986-01-01
The single-breath method represents a simple noninvasive technique for the assessment of capillary blood flow across the lung. However, this method has not gained widespread acceptance, because its accuracy is still being questioned. A rigorous procedure is described for estimating pulmonary blood flow (PBF) using data obtained with the aid of the single-breath method. Attention is given to the minimization of data-processing errors in the presence of measurement errors and to questions regarding a correction for possible loss of CO2 in the lung tissue. It is pointed out that the estimations are based on the exact solution of the underlying differential equations which describe the dynamics of gas exchange in the lung. The reported study demonstrates the feasibility of obtaining highly reliable estimates of PBF from expiratory data in the presence of random measurement errors.
Noninvasive method for assessing the human circadian clock using hair follicle cells
Akashi, Makoto; Soma, Haruhiko; Yamamoto, Takuro; Tsugitomi, Asuka; Yamashita, Shiko; Yamamoto, Takuya; Nishida, Eisuke; Yasuda, Akio; Liao, James K.; Node, Koichi
2010-01-01
A thorough understanding of the circadian clock requires qualitative evaluation of circadian clock gene expression. Thus far, no simple and effective method for detecting human clock gene expression has become available. This limitation has greatly hampered our understanding of human circadian rhythm. Here we report a convenient, reliable, and less invasive method for detecting human clock gene expression using biopsy samples of hair follicle cells from the head or chin. We show that the circadian phase of clock gene expression in hair follicle cells accurately reflects that of individual behavioral rhythms, demonstrating that this strategy is appropriate for evaluating the human peripheral circadian clock. Furthermore, using this method, we indicate that rotating shift workers suffer from a serious time lag between circadian gene expression rhythms and lifestyle. Qualitative evaluation of clock gene expression in hair follicle cells, therefore, may be an effective approach for studying the human circadian clock in the clinical setting. PMID:20798039
Caries Detection Methods Based on Changes in Optical Properties between Healthy and Carious Tissue
Karlsson, Lena
2010-01-01
A conservative, noninvasive or minimally invasive approach to clinical management of dental caries requires diagnostic techniques capable of detecting and quantifying lesions at an early stage, when progression can be arrested or reversed. Objective evidence of initiation of the disease can be detected in the form of distinct changes in the optical properties of the affected tooth structure. Caries detection methods based on changes in a specific optical property are collectively referred to as optically based methods. This paper presents a simple overview of the feasibility of three such technologies for quantitative or semiquantitative assessment of caries lesions. Two of the techniques are well-established: quantitative light-induced fluorescence, which is used primarily in caries research, and laser-induced fluorescence, a commercially available method used in clinical dental practice. The third technique, based on near-infrared transillumination of dental enamel is in the developmental stages. PMID:20454579
Del Ben, Maria; Overi, Diletta; Polimeni, Licia; Carpino, Guido; Labbadia, Giancarlo; Baratta, Francesco; Pastori, Daniele; Noce, Valeria; Gaudio, Eugenio; Angelico, Francesco; Mancone, Carmine
2018-02-18
Nonalcoholic steatohepatitis (NASH) is the critical stage of nonalcoholic fatty liver disease (NAFLD). The persistence of necroinflammatory lesions and fibrogenesis in NASH is the leading cause of liver cirrhosis and, ultimately, hepatocellular carcinoma. To date, the histological examination of liver biopsies, albeit invasive, remains the means to distinguish NASH from simple steatosis (NAFL). Therefore, a noninvasive diagnosis by serum biomarkers is eagerly needed. Here, by a proteomic approach, we analysed the soluble low-molecular-weight protein fragments flushed out from the liver tissue of NAFL and NASH patients. On the basis of the assumption that steatohepatitis leads to the remodelling of the liver extracellular matrix (ECM), NASH-specific fragments were in silico analysed for their involvement in the ECM molecular composition. The 10 kDa C-terminal fragment of the ECM protein vitronectin (VTN) was then selected as a promising circulating biomarker in discriminating NASH. The analysis of sera of patients provided these major findings: the circulating VTN fragment (i) is overexpressed in NASH patients and positively correlates with the NASH activity score (NAS); (ii) originates from the disulfide bond reduction between the V10 and the V65 subunits. In conclusion, V10 determination in the serum could represent a reliable tool for the noninvasive discrimination of NASH from simple steatosis.
Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz
2015-04-01
Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.
2013-01-01
Background A rapid, non-invasive, and inexpensive point-of-care (POC) diagnostic for malaria followed by therapeutic intervention would improve the ability to control infection in endemic areas. Methods A semi-nested PCR amplification protocol is described for quantitative detection of Plasmodium falciparum and is compared to a traditional nested PCR. The approach uses primers that target the P. falciparum dihydrofolate reductase gene. Results This study demonstrates that it is possible to perform an uninterrupted, asymmetric, semi-nested PCR assay with reduced assay time to detect P. falciparum without compromising the sensitivity and specificity of the assay using saliva as a testing matrix. Conclusions The development of this PCR allows nucleic acid amplification without the need to transfer amplicon from the first PCR step to a second reaction tube with nested primers, thus reducing both the chance of contamination and the time for analysis to < two hours. Analysis of the PCR amplicon yield was adapted to lateral flow detection using the quantitative up-converting phosphor (UCP) reporter technology. This approach provides a basis for migration of the assay to a POC microfluidic format. In addition the assay was successfully evaluated with oral samples. Oral fluid collection provides a simple non-invasive method to collect clinical samples. PMID:23433252
Xie, Li-Ting; Yan, Chun-Hong; Zhao, Qi-Yu; He, Meng-Na; Jiang, Tian-An
2018-01-01
Two-dimensional shear wave elastography (2D-SWE) is a rapid, simple and novel noninvasive method that has been proposed for assessing hepatic fibrosis in patients with chronic liver diseases (CLDs) based on measurements of liver stiffness. 2D-SWE can be performed easily at the bedside or in an outpatient clinic and yields immediate results with good reproducibility. Furthermore, 2D-SWE was an efficient method for evaluating liver fibrosis in small to moderately sized clinical trials. However, the quality criteria for the staging of liver fibrosis are not yet well defined. Liver fibrosis is the main pathological basis of liver stiffness and a key step in the progression from CLD to cirrhosis; thus, the management of CLD largely depends on the extent and progression of liver fibrosis. 2D-SWE appears to be an excellent tool for the early detection of cirrhosis and may have prognostic value in this context. Because 2D-SWE has high patient acceptance, it could be useful for monitoring fibrosis progression and regression in individual cases. However, multicenter data are needed to support its use. This study reviews the current status and future perspectives of 2D-SWE for assessments of liver fibrosis and discusses the technical advantages and limitations that impact its effective and rational clinical use. PMID:29531460
NASA Astrophysics Data System (ADS)
Qin, Lin; Fan, Shanhui; Zhou, Chuanqing
2017-04-01
To implement the optical coherence tomography (OCT) angiography on the low scanning speed OCT system, we developed a joint phase and amplitude method to generate 3-D angiograms by analysing the frequency distribution of signals from non-moving and moving scatterers and separating the signals from the tissue and blood flow with high-pass filter dynamically. This approach firstly compensates the sample motion between adjacent A-lines. Then according to the corrected phase information, we used a histogram method to determine the bulk non-moving tissue phases dynamically, which is regarded as the cut-off frequency of a high-pass filter, and separated the moving and non-moving scatters using the mentioned high-pass filter. The reconstructed image can visualize the components of moving scatters flowing, and enables volumetric flow mapping combined with the corrected phase information. Furthermore, retinal and choroidal blood vessels can be simultaneously obtained by separating the B-scan into retinal part and choroidal parts using a simple segmentation algorithm along the RPE. After the compensation of axial displacements between neighbouring images, three-dimensional vasculature of ocular vessels has been visualized. Experiments were performed to demonstrate the effectiveness of the proposed method for 3-D vasculature imaging of human retina and choroid. The results revealed depth-resolved vasculatures in retina and choroid, suggesting that our approach can be used for noninvasive and three-dimensional angiography with a low-speed clinical OCT, and it has a great potential for clinic application.
NASA Astrophysics Data System (ADS)
Yang, Wenming; Liao, Ningfang; Cheng, Haobo; Li, Yasheng; Bai, Xueqiong; Deng, Chengyang
2018-03-01
Non-invasive blood glucose measurement using near infrared (NIR) spectroscopy relies on wavebands that provide reliable information about spectral absorption. In this study, we investigated wavebands which are informative for blood glucose in the NIR shortwave band (900˜1450 nm) and the first overtone band (1450˜1700 nm) through a specially designed NIR Fourier transform spectrometer (FTS), which featured a test fixture (where a sample or subject's finger could be placed) and all-reflective optics, except for a Michelson structure. Different concentrations of glucose solution and seven volunteers who had undergone oral glucose tolerance tests (OGTT) were studied to acquire transmission spectra in the shortwave band and the first overtone band. Characteristic peaks of glucose absorption were identified from the spectra of glucose aqueous solution by second-order derivative processing. The wavebands linked to blood glucose were successfully estimated through spectra of the middle fingertip of OGTT participants by a simple linear regression and correlation coefficient. The light intensity difference showed that glucose absorption in the first overtone band was much more prominent than it was in the shortwave band. The results of the SLR model established from seven OGTTs in total on seven participants enabled a positive estimation of the glucose-linked wavelength. It is suggested that wavebands with prominent characteristic peaks, a high correlation coefficient between blood glucose and light intensity difference and a relatively low standard deviation of predicted values will be the most informative wavebands for transmission non-invasive blood glucose measurement methods. This work provides a guidance for waveband selection for the development of non-invasive NIR blood glucose measurement.
FDTD analysis of a noninvasive hyperthermia system for brain tumors.
Yacoob, Sulafa M; Hassan, Noha S
2012-08-14
Hyperthermia is considered one of the new therapeutic modalities for cancer treatment and is based on the difference in thermal sensitivity between healthy tissues and tumors. During hyperthermia treatment, the temperature of the tumor is raised to 40-45°C for a definite period resulting in the destruction of cancer cells. This paper investigates design, modeling and simulation of a new non-invasive hyperthermia applicator system capable of effectively heating deep seated as well as superficial brain tumors using inexpensive, simple, and easy to fabricate components without harming surrounding healthy brain tissues. The proposed hyperthermia applicator system is composed of an air filled partial half ellipsoidal chamber, a patch antenna, and a head model with an embedded tumor at an arbitrary location. The irradiating antenna is placed at one of the foci of the hyperthermia chamber while the center of the brain tumor is placed at the other focus. The finite difference time domain (FDTD) method is used to compute both the SAR patterns and the temperature distribution in three different head models due to two different patch antennas at a frequency of 915 MHz. The obtained results suggest that by using the proposed noninvasive hyperthermia system it is feasible to achieve sufficient and focused energy deposition and temperature rise to therapeutic values in deep seated as well as superficial brain tumors without harming surrounding healthy tissue. The proposed noninvasive hyperthermia system proved suitable for raising the temperature in tumors embedded in the brain to therapeutic values by carefully selecting the systems components. The operator of the system only needs to place the center of the brain tumor at a pre-specified location and excite the antenna at a single frequency of 915 MHz. Our study may provide a basis for a clinical applicator prototype capable of heating brain tumors.
NASA Astrophysics Data System (ADS)
Babic, Z.; Pilipovic, R.; Risojevic, V.; Mirjanic, G.
2016-06-01
Honey bees have crucial role in pollination across the world. This paper presents a simple, non-invasive, system for pollen bearing honey bee detection in surveillance video obtained at the entrance of a hive. The proposed system can be used as a part of a more complex system for tracking and counting of honey bees with remote pollination monitoring as a final goal. The proposed method is executed in real time on embedded systems co-located with a hive. Background subtraction, color segmentation and morphology methods are used for segmentation of honey bees. Classification in two classes, pollen bearing honey bees and honey bees that do not have pollen load, is performed using nearest mean classifier, with a simple descriptor consisting of color variance and eccentricity features. On in-house data set we achieved correct classification rate of 88.7% with 50 training images per class. We show that the obtained classification results are not far behind from the results of state-of-the-art image classification methods. That favors the proposed method, particularly having in mind that real time video transmission to remote high performance computing workstation is still an issue, and transfer of obtained parameters of pollination process is much easier.
Multispectral imaging approach for simplified non-invasive in-vivo evaluation of gingival erythema
NASA Astrophysics Data System (ADS)
Eckhard, Timo; Valero, Eva M.; Nieves, Juan L.; Gallegos-Rueda, José M.; Mesa, Francisco
2012-03-01
Erythema is a common visual sign of gingivitis. In this work, a new and simple low-cost image capture and analysis method for erythema assessment is proposed. The method is based on digital still images of gingivae and applied on a pixel-by-pixel basis. Multispectral images are acquired with a conventional digital camera and multiplexed LED illumination panels at 460nm and 630nm peak wavelength. An automatic work-flow segments teeth from gingiva regions in the images and creates a map of local blood oxygenation levels, which relates to the presence of erythema. The map is computed from the ratio of the two spectral images. An advantage of the proposed approach is that the whole process is easy to manage by dental health care professionals in clinical environment.
Beaded-chain collars: A new method to radiotag kangaroo rats for short-term studies
Harker, M.B.; Rathbun, G.B.; Langtimm, C.A.
1999-01-01
To study burrow use by small mammals, we needed to develop a simple, non-invasive radiotag for the endangered giant kangaroo rat (Dipodomys ingens). We designed and tested a radiocollar made of beaded-chain on 4 captive Heermann's kangaroo rats (D. heermanii). Attachment of the collar required no anesthesia, the collar was easily fitted in 1-2 minutes, and it caused minimal stress to the animals. Once the collar design and attachment technique were perfected on the surrogate animals, we fitted radiocollars on 48 giant kangaroo rats for about 15 days. Upon recapture, 12 animals showed some minor fur or skin abrasion on the neck. Overall, the attachment performed as expected and proved to be a reliable method to radiotrack kangaroo rats during our short-term field study.
Luminescent Tension-Indicating Orthopedic Strain Gauges for Non-Invasive Measurements Through Tissue
NASA Technical Reports Server (NTRS)
Anker, Jeffrey (Inventor); Anderson, Dakota (Inventor); Heath, Jonathon (Inventor); Rogalski, Melissa (Inventor)
2015-01-01
Strain gauges that can provide information with regard to the state of implantable devices are described. The strain gauges can exhibit luminescence that is detectable through living tissue, and the detectable luminescent emission can vary according to the strain applied to the gauge. A change in residual strain of the device can signify a loss of mechanical integrity and/or loosening of the implant, and this can be non-invasively detected either by simple visual detection of the luminescent emission or through examination of the emission with a detector such as a spectrometer or a camera.
Fluorescence imaging of tryptophan and collagen cross-links to evaluate wound closure ex vivo
NASA Astrophysics Data System (ADS)
Wang, Ying; Ortega-Martinez, Antonio; Farinelli, Bill; Anderson, R. R.; Franco, Walfre
2016-02-01
Wound size is a key parameter in monitoring healing. Current methods to measure wound size are often subjective, time-consuming and marginally invasive. Recently, we developed a non-invasive, non-contact, fast and simple but robust fluorescence imaging (u-FEI) method to monitor the healing of skin wounds. This method exploits the fluorescence of native molecules to tissue as functional and structural markers. The objective of the present study is to demonstrate the feasibility of using variations in the fluorescence intensity of tryptophan and cross-links of collagen to evaluate proliferation of keratinocyte cells and quantitate size of wound during healing, respectively. Circular dermal wounds were created in ex vivo human skin and cultured in different media. Two serial fluorescence images of tryptophan and collagen cross-links were acquired every two days. Histology and immunohistology were used to validate correlation between fluorescence and epithelialization. Images of collagen cross-links show fluorescence of the exposed dermis and, hence, are a measure of wound area. Images of tryptophan show higher fluorescence intensity of proliferating keratinocytes forming new epithelium, as compared to surrounding keratinocytes not involved in epithelialization. These images are complementary since collagen cross-links report on structure while tryptophan reports on function. HE and immunohistology show that tryptophan fluorescence correlates with newly formed epidermis. We have established a fluorescence imaging method for studying epithelialization processes during wound healing in a skin organ culture model, our approach has the potential to provide a non-invasive, non-contact, quick, objective and direct method for quantitative measurements in wound healing in vivo.
Non-invasive, investigative methods in skin aging.
Longo, C; Ciardo, S; Pellacani, G
2015-12-01
A precise and noninvasive quantification of aging is of outmost importance for in vivo assessment of the skin aging "stage", and thus acts to minimize it. Several bioengineering methods have been proposed to objectively, precisely, and non-invasively measure skin aging, and to detect early skin damage, that is sub-clinically observable. In this review we have described the most relevant methods that have emerged from recently introduced technologies, aiming at quantitatively assessing the effects of aging on the skin.
Hayama, Tomonari; Yamaguchi, Tomoyuki; Kato-Itoh, Megumi; Ishii, Yumiko; Mizuno, Naoaki; Umino, Ayumi; Sato, Hideyuki; Sanbo, Makoto; Hamanaka, Sanae; Masaki, Hideki; Hirabayashi, Masumi; Nakauchi, Hiromitsu
2016-06-01
Round spermatid injection (ROSI) into unfertilized oocytes enables a male with a severe spermatogenesis disorder to have children. One limitation of the application of this technique in the clinic is the identification and isolation of round spermatids from testis tissue. Here we developed an efficient and simple method to isolate rodent haploid round spermatids using flow cytometric cell sorting, based on DNA content (stained with Hoechst 33342 or Dye Cycle Violet) or by cell diameter and granularity (forward and side scatter). ROSI was performed with round spermatids selected by flow cytometry, and we obtained healthy offspring from unstained cells. This non-invasive method could therefore be an effective option for breeding domestic animals and human male infertility treatment. Mol. Reprod. Dev. 83: 488-496, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Age estimation standards for a Western Australian population using the coronal pulp cavity index.
Karkhanis, Shalmira; Mack, Peter; Franklin, Daniel
2013-09-10
Age estimation is a vital aspect in creating a biological profile and aids investigators by narrowing down potentially matching identities from the available pool. In addition to routine casework, in the present global political scenario, age estimation in living individuals is required in cases of refugees, asylum seekers, human trafficking and to ascertain age of criminal responsibility. Thus robust methods that are simple, non-invasive and ethically viable are required. The aim of the present study is, therefore, to test the reliability and applicability of the coronal pulp cavity index method, for the purpose of developing age estimation standards for an adult Western Australian population. A total of 450 orthopantomograms (220 females and 230 males) of Australian individuals were analyzed. Crown and coronal pulp chamber heights were measured in the mandibular left and right premolars, and the first and second molars. These measurements were then used to calculate the tooth coronal index. Data was analyzed using paired sample t-tests to assess bilateral asymmetry followed by simple linear and multiple regressions to develop age estimation models. The most accurate age estimation based on simple linear regression model was with mandibular right first molar (SEE ±8.271 years). Multiple regression models improved age prediction accuracy considerably and the most accurate model was with bilateral first and second molars (SEE ±6.692 years). This study represents the first investigation of this method in a Western Australian population and our results indicate that the method is suitable for forensic application. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Non-invasive means of measuring hepatic fat content.
Mehta, Sanjeev-R; Thomas, E-Louise; Bell, Jimmy-D; Johnston, Desmond-G; Taylor-Robinson, Simon-D
2008-06-14
Hepatic steatosis affects 20% to 30% of the general adult population in the western world. Currently, the technique of choice for determining hepatic fat deposition and the stage of fibrosis is liver biopsy. However, it is an invasive procedure and its use is limited, particularly in children. It may also be subject to sampling error. Non-invasive techniques such as ultrasound, computerised tomography (CT), magnetic resonance imaging (MRI) and proton magnetic resonance spectroscopy ((1)H MRS) can detect hepatic steatosis, but currently cannot distinguish between simple steatosis and steatohepatitis, or stage the degree of fibrosis accurately. Ultrasound is widely used to detect hepatic steatosis, but its sensitivity is reduced in the morbidly obese and also in those with small amounts of fatty infiltration. It has been used to grade hepatic fat content, but this is subjective. CT can detect hepatic steatosis, but exposes subjects to ionising radiation, thus limiting its use in longitudinal studies and in children. Recently, magnetic resonance (MR) techniques using chemical shift imaging have provided a quantitative assessment of the degree of hepatic fatty infiltration, which correlates well with liver biopsy results in the same patients. Similarly, in vivo (1)H MRS is a fast, safe, non-invasive method for the quantification of intrahepatocellular lipid (IHCL) levels. Both techniques will be useful tools in future longitudinal clinical studies, either in examining the natural history of conditions causing hepatic steatosis (e.g. non-alcoholic fatty liver disease), or in testing new treatments for these conditions.
Koulouris, N G; Latsi, P; Dimitroulis, J; Jordanoglou, B; Gaga, M; Jordanoglou, J
2001-06-01
The lack of methodology for measuring the alveolar carbon dioxide tension (PA,CO2) has forced investigators to make several assumptions, such as that PA,CO2 is equal to end-tidal (PET,CO2) and arterial CO2 tension (Pa,CO2). The present study measured the mean PA,CO2 and Bohr's dead space ratio (Bohr's dead space/tidal volume (VD,Bohr/VT)) during tidal breathing. The method used is a new, simple and noninvasive technique, based on the analysis of the expired CO2 volume per breath (VCO2) versus the exhaled VT. This curve was analysed in 21 normal, healthy subjects and 35 chronic obstructive pulmonary disease (COPD) patients breathing tidally through a mouthpiece apparatus in the sitting position. It is shown that: 1) PA,CO2 is similar to Pa,CO2 in normal subjects, whilst it is significantly lower than Pa,CO2 in COPD patients; 2) PA,CO2 is significantly higher than PET,CO2 in all subjects, especially in COPD patients; 3) VD,Bohr/VT is increased in COPD patients as compared to normal subjects; and 4) VD,Bohr/VT is lower than the "physiological" dead space ratio (VD,phys/VT) in COPD patients. It is concluded that the expired carbon dioxide versus tidal volume curve is a useful tool for research and clinical work, because it permits the noninvasive and accurate measurement of Bohr's dead space and mean alveolar carbon dioxide tension accurately during spontaneous breathing.
Scabies: should we always perform dermatoscopy?
Betti, S; Bassi, A; Prignano, F; Lotti, T
2009-06-01
The authors describe a case of scabies in a 80 year-old woman with a history of intense itching. Lesions were not present in the body parts where they usually occur, but few erythematous and papular lesions were visible on the rear trunk. Diagnosis was not based on the usual clinical features or on the traditional method of microscopic examination but a high magnification videodermatoscopy was performed and, on a burrow-like scabby lesions at the rear trunk, a mite was found. This paper focuses on the importance of the videodermatoscopy, a simple, quick, non-expensive and non-invasive technique, that enhances the diagnostic capability in a case of scabies, which is not localized in the characteristic zones.
Liquid biopsy for early stage lung cancer.
Liang, Wenhua; Zhao, Yi; Huang, Weizhe; Liang, Hengrui; Zeng, Haikang; He, Jianxing
2018-04-01
Liquid biopsy, which analyzes biological fluids especially blood specimen to detect and quantify circulating cancer biomarkers, have been rapidly introduced and represents a promising potency in clinical practice of lung cancer diagnosis and prognosis. Unlike conventional tissue biopsy, liquid biopsy is non-invasive, safe, simple in procedure, and is not influenced by manipulators' skills. Notably, some circulating cancer biomarkers are already detectable in disease with low-burden, making liquid biopsy feasible in detecting early stage lung cancer. In this review, we described a landscape of different liquid biopsy methods by highlighting the rationale and advantages, accessing the value of various circulating biomarkers and discussing their possible future development in the detection of early lung cancer.
Lakatos, Bálint; Kovács, Attila; Tokodi, Márton; Doronina, Alexandra; Merkely, Béla
2016-07-01
Accurate assessment of right ventricular geometry and function is of high clinical importance. However, several limitations have to be taken into consideration if using conventional echocardiographic parameters. Advanced echocardiographic techniques, such as speckle-tracking analysis or 3D echocardiography are reliable and simple tools providing a cost-effective and non-invasive alternative of current modalities used to characterize the right ventricle. There is a growing interest in the diagnostic and prognostic value of these methods regarding pathological (right ventricular infarction, pulmonary hypertension, arrhythmogenic right ventricular dysplasia, follow-up of heart transplantation) and even physiological (athlete's heart) alterations of the right ventricle. Orv. Hetil., 2016, 157(29), 1139-1146.
Wang, Ting; Zhang, Kun-He; Hu, Piao-Ping; Huang, Zeng-Yong; Zhang, Pan; Wan, Qin-Si; Huang, De-Qiang; Lv, Nong-Hua
2016-09-27
The diagnosis of early, small and alpha-fetoprotein (AFP)-negative primary hepatic carcinomas (PHCs) remains a significant challenge. We developed a simple and robust approach to noninvasively detect these PHCs. A rapid, high-throughput and single-tube method was firstly developed to measure serum autofluorescence and cell-free DNA (cfDNA)-related fluorescence using a real-time PCR system, and both types of serum fluorescence were measured and routine laboratory data were collected in 1229 subjects, including 353 PHC patients, 331 liver cirrhosis (LC) patients, 213 chronic hepatitis (CH) patients and 332 normal controls (NC). The results showed that fluorescence indicators of PHC differed from those of NC, CH and LC to various extents, and all of them were not associated with age, gender, or AFP level. The logistic regression models established with the fluorescence indicators alone and combined with AFP, hepatic function tests and blood cell analyses were valuable for distinguishing early, small, AFP-negative and all PHC from LC, CH, NC and all non-PHC, with areas under the receiver operating characteristic curves 0.857-0.993 and diagnostic accuracies 80.2-97.7%. Conclusively, serum autofluorescence and cfDNA-related fluorescence are able to be rapidly and simultaneously measured by our simple method and valuable for diagnosing early, small and AFP-negative PHCs, especially integrating with AFP and conventional blood tests.
A simple highly efficient non invasive EMG-based HMI.
Vitiello, N; Olcese, U; Oddo, C M; Carpaneto, J; Micera, S; Carrozza, M C; Dario, P
2006-01-01
Muscle activity recorded non-invasively is sufficient to control a mobile robot if it is used in combination with an algorithm for its asynchronous analysis. In this paper, we show that several subjects successfully can control the movements of a robot in a structured environment made up of six rooms by contracting two different muscles using a simple algorithm. After a small training period, subjects were able to control the robot with performances comparable to those achieved manually controlling the robot.
Sulaiman, Nabil; Hussein, Amal; Elbadawi, Salah; Abusnana, Salah; Zimmet, Paul
2018-01-01
Objective The objective of this study was to develop a simple non-invasive risk score, specific to the United Arab Emirates (UAE) citizens, to identify individuals at increased risk of having undiagnosed type 2 diabetes mellitus. Research design and methods A retrospective analysis of the UAE National Diabetes and Lifestyle data was conducted. The data included demographic and anthropometric measurements, and fasting blood glucose. Univariate analyses were used to identify the risk factors for diabetes. The risk score was developed for UAE citizens using a stepwise forward regression model. Results A total of 872 UAE citizens were studied. The overall prevalence of diabetes in the UAE adult citizens in the Northern Emirates was 25.1%. The significant risk factors identified for diabetes were age (≥35 years), a family history of diabetes mellitus, hypertension, body mass index ≥30.0 and waist-to-hip ratio ≥0.90 for males and ≥0.85 for females. The performance of the model was moderate in terms of sensitivity (75.4%, 95% CI 68.3 to 81.7) and specificity (70%, 95% CI 65.8 to 73.9). The area under the receiver-operator characteristic curve was 0.82 (95% CI 0.78 to 0.86). Conclusions A simple, non-invasive risk score model was developed to help to identify those at high risk of having diabetes among UAE citizens. This score could contribute to the efficient and less expensive earlier detection of diabetes in this high-risk population. PMID:29629178
Variations in respiratory sounds in relation to fluid accumulation in the upper airways.
Yadollahi, Azadeh; Rudzicz, Frank; Montazeri, Aman; Bradley, T Douglas
2013-01-01
Obstructive sleep apnea (OSA) is a common disorder due to recurrent collapse of the upper airway (UA) during sleep that increases the risk for several cardiovascular diseases. Recently, we showed that nocturnal fluid accumulation in the neck can narrow the UA and predispose to OSA. Our goal is to develop non-invasive methods to study the pathogenesis of OSA and the factors that increase the risks of developing it. Respiratory sound analysis is a simple and non-invasive way to study variations in the properties of the UA. In this study we examine whether such analysis can be used to estimate the amount of neck fluid volume and whether fluid accumulation in the neck alters the properties of these sounds. Our acoustic features include estimates of formants, pitch, energy, duration, zero crossing rate, average power, Mel frequency power, Mel cepstral coefficients, skewness, and kurtosis across segments of sleep. Our results show that while all acoustic features vary significantly among subjects, only the variations in respiratory sound energy, power, duration, pitch, and formants varied significantly over time. Decreases in energy and power over time accompany increases in neck fluid volume which may indicate narrowing of UA and consequently an increased risk of OSA. Finally, simple discriminant analysis was used to estimate broad classes of neck fluid volume from acoustic features with an accuracy of 75%. These results suggest that acoustic analysis of respiratory sounds might be used to assess the role of fluid accumulation in the neck on the pathogenesis of OSA.
Maity, Abhijit; Banik, Gourab D; Ghosh, Chiranjit; Som, Suman; Chaudhuri, Sujit; Daschakraborty, Sunil B; Ghosh, Shibendu; Ghosh, Barnali; Raychaudhuri, Arup K; Pradhan, Manik
2014-03-01
A residual gas analyzer (RGA) coupled with a high vacuum chamber is described for the non-invasive diagnosis of the Helicobacter pylori (H. pylori) infection through ¹³C-urea breath analysis. The present RGA-based mass spectrometry (MS) method is capable of measuring high-precision ¹³CO₂ isotope enrichments in exhaled breath samples from individuals harboring the H. pylori infection. The system exhibited 100% diagnostic sensitivity, and 93% specificity alongside positive and negative predictive values of 95% and 100%, respectively, compared with invasive endoscopy-based biopsy tests. A statistically sound diagnostic cut-off value for the presence of H. pylori was determined to be 3.0‰ using a receiver operating characteristic curve analysis. The diagnostic accuracy and validity of the results are also supported by optical off-axis integrated cavity output spectroscopy measurements. The δ¹³(DOB)C‰ values of both methods correlated well (R² = 0.9973 at 30 min). The RGA-based instrumental setup described here is simple, robust, easy-to-use and more portable and cost-effective compared to all other currently available detection methods, thus making it a new point-of-care medical diagnostic tool for the purpose of large-scale screening of the H. pylori infection in real time. The RGA-MS technique should have broad applicability for ¹³C-breath tests in a wide range of biomedical research and clinical diagnostics for many other diseases and metabolic disorders.
(1)H nuclear magnetic resonance (NMR) as a tool to measure dehydration in mice.
Li, Matthew; Vassiliou, Christophoros C; Colucci, Lina A; Cima, Michael J
2015-08-01
Dehydration is a prevalent pathology, where loss of bodily water can result in variable symptoms. Symptoms can range from simple thirst to dire scenarios involving loss of consciousness. Clinical methods exist that assess dehydration from qualitative weight changes to more quantitative osmolality measurements. These methods are imprecise, invasive, and/or easily confounded, despite being practiced clinically. We investigate a non-invasive, non-imaging (1)H NMR method of assessing dehydration that attempts to address issues with existing clinical methods. Dehydration was achieved by exposing mice (n = 16) to a thermally elevated environment (37 °C) for up to 7.5 h (0.11-13% weight loss). Whole body NMR measurements were made using a Bruker LF50 BCA-Analyzer before and after dehydration. Physical lean tissue, adipose, and free water compartment approximations had NMR values extracted from relaxation data through a multi-exponential fitting method. Changes in before/after NMR values were compared with clinically practiced metrics of weight loss (percent dehydration) as well as blood and urine osmolality. A linear correlation between tissue relaxometry and both animal percent dehydration and urine osmolality was observed in lean tissue, but not adipose or free fluids. Calculated R(2) values for percent dehydration were 0.8619 (lean, P < 0.0001), 0.5609 (adipose, P = 0.0008), and 0.0644 (free fluids, P = 0.3445). R(2) values for urine osmolality were 0.7760 (lean, P < 0.0001), 0.5005 (adipose, P = 0.0022), and 0.0568 (free fluids, P = 0.3739). These results suggest that non-imaging (1)H NMR methods are capable of non-invasively assessing dehydration in live animals. Copyright © 2015 John Wiley & Sons, Ltd.
A new diode laser acupuncture therapy apparatus
NASA Astrophysics Data System (ADS)
Li, Chengwei; Huang, Zhen; Li, Dongyu; Zhang, Xiaoyuan
2006-06-01
Since the first laser-needles acupuncture apparatus was introduced in therapy, this kind of apparatus has been well used in laser biomedicine as its non-invasive, pain- free, non-bacterium, and safetool. The laser acupuncture apparatus in this paper is based on single-chip microcomputer and associated by semiconductor laser technology. The function like traditional moxibustion including reinforcing and reducing is implemented by applying chaos method to control the duty cycle of moxibustion signal, and the traditional lifting and thrusting of acupuncture is implemented by changing power output of the diode laser. The radiator element of diode laser is made and the drive circuit is designed. And chaos mathematic model is used to produce deterministic class stochastic signal to avoid the body adaptability. This function covers the shortages of continuous irradiation or that of simple disciplinary stimulate signal, which is controlled by some simple electronic circuit and become easily adjusted by human body. The realization of reinforcing and reducing of moxibustion is technological innovation in traditional acupuncture coming true in engineering.
Underlying neural mechanisms of mirror therapy: Implications for motor rehabilitation in stroke.
Arya, Kamal Narayan
2016-01-01
Mirror therapy (MT) is a valuable method for enhancing motor recovery in poststroke hemiparesis. The technique utilizes the mirror-illusion created by the movement of sound limb that is perceived as the paretic limb. MT is a simple and economical technique than can stimulate the brain noninvasively. The intervention unquestionably has neural foundation. But the underlying neural mechanisms inducing motor recovery are still unclear. In this review, the neural-modulation due to MT has been explored. Multiple areas of the brain such as the occipital lobe, dorsal frontal area and corpus callosum are involved during the simple MT regime. Bilateral premotor cortex, primary motor cortex, primary somatosensory cortex, and cerebellum also get reorganized to enhance the function of the damaged brain. The motor areas of the lesioned hemisphere receive visuo-motor processing information through the parieto-occipital lobe. The damaged motor cortex responds variably to the MT and may augment true motor recovery. Mirror neurons may also play a possible role in the cortico-stimulatory mechanisms occurring due to the MT.
Novel laser Doppler flowmeter for pulpal blood flow measurements
NASA Astrophysics Data System (ADS)
Zang, De Yu; Millerd, James E.; Wilder-Smith, Petra B. B.; Arrastia-Jitosho, Anna-Marie A.
1996-04-01
We have proposed and experimentally demonstrated a new configuration of laser Doppler flowmetry for dental pulpal blood flow measurements. To date, the vitality of a tooth can be determined only by subjective thermal or electric tests, which are of questionable reliability and may induced pain in patient. Non-invasive techniques for determining pulpal vascular reactions to injury, treatment, and medication are in great demand. The laser Doppler flowmetry technique is non-invasive; however, clinical studies have shown that when used to measure pulpal blood flow the conventional back-scattering Doppler method suffers from low signal-to-noise ratio (SNR) and unreliable flux readings rendering it impossible to calibrate. A simplified theoretical model indicates that by using a forward scattered geometry the detected signal has a much higher SNR and can be calibrated. The forward scattered signal is readily detectable due to the fact that teeth are relatively thin organs with moderate optical loss. A preliminary experiment comparing forward scattered detection with conventional back- scattered detection was carried out using an extracted human molar. The results validated the findings of the simple theoretical model and clearly showed the utility of the forward scattering geometry. The back-scattering method had readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth. The forward scattered method had consistent readings (within 10%) that were independent of the sensor position, a signal-to-noise ratio that was at least 5.6 times higher than the back-scattering method, and a linear response to flow rate.
Huang, Chenyu; Ogawa, Rei; Hyakusoku, Hiko
2014-08-01
The current skin graft fixation methods for digits, including the Kirschner wire insertion technique, can be limited by inadequate or excessive fixation and complications such as infection or secondary injuries. Therefore, the external wire-frame fixation method was invented and used for skin grafting of digits. This study aimed to investigate external wire-frame fixation of digital skin grafts as a non-invasive alternative to the K-wire insertion method. In 2005-2012, 15 patients with burn scar contractures on the hand digits received a skin graft that was then fixed with an external wire frame. The intra-operative time needed to make the wire frame, the postoperative time to frame and suture removal, the graft survival rate, the effect of contracture release and the complications were recorded. In all cases, the contracture release was 100%. The complete graft survival rate was 98.6%. Four patients had epithelial necrosis in <5% of the total area. There were no other complications such as pressure ulcer or hypoxia of fingers. External wire-frame fixation is simple, minimally invasive and a custom-made technique for skin grafting of the fingers. It was designed for its potential benefits and the decreased risk it poses to patients with scar contractures on their fingers. It can be implemented in three phases of grafting, does not affect the epiphyseal line or subsequent finger growth and is suitable for children with multi-digit involvement. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Cup-Shaped Superparamagnetic Hemispheres for Size-Selective Cell Filtration
Kim, Hyonchol; Terazono, Hideyuki; Takei, Hiroyuki; Yasuda, Kenji
2014-01-01
We propose a new method of size separation of cells exploiting precisely size-controlled hemispherical superparamagnetic microparticles. A three-layered structure of a 2-nm nickel layer inserted between 15-nm silicon dioxide layers was formed on polystyrene cast spheres by vapor deposition. The polystyrene was then removed by burning and the hemispherical superparamagnetic microparticles, “magcups”, were obtained. The standard target cells (CCRF-CEM, 12 ± 2 μm) were mixed with a set of different sizes of the fabricated magcups, and we confirmed that the cells were captured in the magcups having cavities larger than 15 μm in diameter, and then gathered by magnetic force. The collected cells were grown in a culture medium without any damage. The results suggest that this method is quick, simple and non-invasive size separation of target cells. PMID:25219418
Detecting protein losing enteropathy by Tc-99m dextran scintigraphy: a novel experience.
Kapoor, Seema; Ratan, Simmi K; Kashyap, Ravi; Mittal, S K; Rajeshwari, K; Rawat, H; Verma, Jyoti
2002-09-01
To evaluate protien using enteropathy by Tc-99m dextran scintigraphy. Methods for detecting protein loss from the intestine revolve around fecal nitrogen excretion, the clearance of alpha-1 antitrypsin in stools and by endoscopic biopsy. The diagnosis of protein-losing enteropathy (PLE) can also be established by a scintigraphic method that is noninvasive, simple and requires no patient preparation or motivation. This diagnostic modality can also delineate the site of protein loss, thereby offering a targeted approach, and if need be, surgery. Radiolabelling of a non-protein, noncolloidal, nonparticulate and biofriendly molecule like dextran with Technetium-99m for imaging enteric protein loss was utilized in imaging eight children with PLE. The results were encouraging. The authors advocate the use of this diagnostic tool in identifying patients with PLE, particularly in the pediatric age group.
NASA Astrophysics Data System (ADS)
Arenas, Gustavo; Noriega, Sergio; Vallo, Claudia; Duchowicz, Ricardo
2007-03-01
A fiber optic sensing method based on a Fizeau-type interferometric scheme was employed for monitoring linear polymerization shrinkage in dental restoratives. This technique offers several advantages over the conventional methods of measuring polymerization contraction. This simple, compact, non-invasive and self-calibrating system competes with both conventional and other high-resolution bulk interferometric techniques. In this work, an analysis of the quality of interference signal and fringes visibility was performed in order to characterize their resolution and application range. The measurements of percent linear contraction as a function of the sample thickness were carried out in this study on two dental composites: Filtek P60 (3M ESPE) Posterior Restorer and Filtek Z250 (3M ESPE) Universal Restorer. The results were discussed with respect to others obtained employing alternative techniques.
Guo, Lin; Wang, Yu; Zheng, Yiliang; Huang, Zhipeng; Cheng, Yiyuan; Ye, Jiannong; Chu, Qingcui; Huang, Dongping
2016-03-01
A capillary electrophoresis approach with capacitively coupled contactless conductivity detection method has been developed for the determination of inorganic metabolites (thiocyanate, nitrite and nitrate) in human saliva. Field amplified sample injection, as a simple sample stacking technique, was used in conjunction for online preconcentration of above inorganic anions. A selective separation for the target anions from other coexisting constituents present in saliva could be obtained within 14min in a 10mmol/L His-90mmol/L HAc buffer (pH 3.70) at the separation voltage of -18kV. The limits of detection and limits of quantification of the three analytes were within the range of 3.1-4.9ng/mL (S/N=3) and 10-16ng/mL (S/N=10), respectively. The average recovery data were in the range of 81-108% at three different concentrations. This method provides a simple, rapid and direct approach for metabolite analyses of nitric oxide and cyanide based on noninvasive saliva sample, which presents a potential fast screening tool for clinical test. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Salinas, F. S.; Lancaster, J. L.; Fox, P. T.
2009-06-01
Transcranial magnetic stimulation (TMS) delivers highly localized brain stimulations via non-invasive externally applied magnetic fields. This non-invasive, painless technique provides researchers and clinicians with a unique tool capable of stimulating both the central and peripheral nervous systems. However, a complete analysis of the macroscopic electric fields produced by TMS has not yet been performed. In this paper, we addressed the importance of the secondary E-field created by surface charge accumulation during TMS using the boundary element method (BEM). 3D models were developed using simple head geometries in order to test the model and compare it with measured values. The effects of tissue geometry, size and conductivity were also investigated. Finally, a realistically shaped head model was used to assess the effect of multiple surfaces on the total E-field. Secondary E-fields have the greatest impact at areas in close proximity to each tissue layer. Throughout the head, the secondary E-field magnitudes typically range from 20% to 35% of the primary E-field's magnitude. The direction of the secondary E-field was generally in opposition to the primary E-field; however, for some locations, this was not the case (i.e. going from high to low conductivity tissues). These findings show that realistically shaped head geometries are important for accurate modeling of the total E-field.
Guissart, Claire; Debant, Vanessa; Desgeorges, Marie; Bareil, Corinne; Raynal, Caroline; Toga, Caroline; Pritchard, Victoria; Koenig, Michel; Claustres, Mireille; Vincent, Marie-Claire
2015-02-01
Analysis of circulating cell-free fetal DNA (cffDNA) in maternal plasma is very promising for early diagnosis of monogenic diseases. However, this approach is not yet available for routine use and remains technically challenging because of the low concentration of cffDNA, which is swamped by the overwhelming maternal DNA. To make clinical applications more readily accessible, we propose a new approach based on mutant enrichment with 3'-modified oligonucleotides (MEMO) PCR along with real-time PCR to selectively amplify from the maternal blood the paternally inherited fetal allele that is not present in the maternal genome. The first proof of concept of this strategy was displayed for cystic fibrosis by the accuracy of our detection of the p.Gly542* mutation used as the initial developmental model. Subsequently, a retrospective study of plasmas originating from two pregnant women carrying a fetus with private mutation confirmed the effectiveness of our method. We confirmed the presence of cffDNA in the studied samples by the identification of a tri-allelic DNA profile using a miniSTR kit. This new non-invasive prenatal diagnosis test offers numerous advantages over current methods: it is simple, cost effective, time efficient and does not require complex equipment or bioinformatics settings. Moreover, our assays for different private mutations demonstrate the viability of this approach in clinical settings for monogenic disorders.
Verification of intravenous catheter placement by auscultation--a simple, noninvasive technique.
Lehavi, Amit; Rudich, Utay; Schechtman, Moshe; Katz, Yeshayahu Shai
2014-01-01
Verification of proper placement of an intravenous catheter may not always be simple. We evaluated the auscultation technique for this purpose. Twenty healthy volunteers were randomized for 18G catheter inserted intravenously either in the right (12) or left arm (8), and subcutaneously in the opposite arm. A standard stethoscope was placed over an area approximately 3 cm proximal to the tip of the catheter in the presumed direction of the vein to grade on a 0-6 scale the murmur heard by rapidly injecting 2 mL of NaCl 0.9% solution. The auscultation was evaluated by a blinded staff anesthesiologist. All 20 intravenous injection were evaluated as flow murmurs, and were graded an average 5.65 (±0.98), whereas all 20 subcutaneous injections were evaluated as either crackles or no sound, and were graded an average 2.00 (±1.38), without negative results. Sensitivity was calculated as 95%. Specificity and Kappa could not be calculated due to an empty false-positive group. Being simple, handy and noninvasive, we recommend to use the auscultation technique for verification of the proper placement of an intravenous catheter when uncertain of its position. Data obtained in our limited sample of healthy subjects need to be confirmed in the clinical setting.
Thierry, Alain R
2016-01-01
Circulating cell-free DNA (cfDNA) is a valuable source of tumor material available with a simple blood sampling enabling a noninvasive quantitative and qualitative analysis of the tumor genome. cfDNA is released by tumor cells and exhibits the genetic and epigenetic alterations of the tumor of origin. Circulating cell-free DNA (cfDNA) analysis constitutes a hopeful approach to provide a noninvasive tumor molecular test for cancer patients. Based upon basic research on the origin and structure of cfDNA, new information on circulating cell-free DNA (cfDNA) structure, and specific determination of cfDNA fragmentation and size, we revisited Q-PCR-based method and recently developed a the allele-specific-Q-PCR-based method with blocker (termed as Intplex) which is the first multiplexed test for cfDNA. This technique, named Intplex(®) and based on a refined Q-PCR method, derived from critical observations made on the specific structure and size of cfDNA. It enables the simultaneous determination of five parameters: the cfDNA total concentration, the presence of a previously known point mutation, the mutant (tumor) cfDNA concentration (ctDNA), the proportion of mutant cfDNA, and the cfDNA fragmentation index. Intplex(®) has enabled the first clinical validation of ctDNA analysis in oncology by detecting KRAS and BRAF point mutations in mCRC patients and has demonstrated that a blood test could replace tumor section analysis for the detection of KRAS and BRAF mutations. The Intplex(®) test can be adapted to all mutations, genes, or cancers and enables rapid, highly sensitive, cost-effective, and repetitive analysis. As regards to the determination of mutations on cfDNA Intplex(®) is limited to the mutational status of known hotspot mutation; it is a "targeted approach." However, it offers the opportunity in detecting quantitatively and dynamically mutation and could constitute a noninvasive attractive tool potentially allowing diagnosis, prognosis, theranostics, therapeutic monitoring, and follow-up of cancer patients expanding the scope of personalized cancer medicine.
Development of a Voided Urine Assay for Detecting Prostate Cancer Noninvasively: A Pilot Study
Trabulsi, Edouard J.; Tripathi, Sushil K.; Gomella, Leonard; Solomides, Charalambos; Wickstrom, Eric; Thakur, Mathew L.
2017-01-01
Objective To validate a hypothesis that prostate cancer (PCa) can be detected noninvasively by a simple and reliable assay by targeting genomic VPAC receptors expressed on malignant PCa cells shed in voided urine. Materials and Methods VPAC receptors were targeted with a specific biomolecule, TP4303, developed in our laboratory. With an IRB “exempt” approval of use of de-identified discarded samples, an aliquot of urine collected as a standard of care, from patients presenting to the urology clinic, (N=207, M= 176, F= 31, 21 years or older) was cytospun. The cells were fixed and treated with TP4303 and 4, 6 Dimidino-2-phenylindole, Dihydrochloride (DAPI). The cells were then observed under a microscope and cells with TP4303 orange fluorescence around the blue (DAPI) nucleus were considered malignant and those only with blue nucleus were regarded as normal. VPAC presence was validated using receptor blocking assay and cell malignancy was confirmed by PCa gene profile examination. Results The urine specimens were labeled only with gender and presenting diagnosis, with no personal health identifiers or other clinical data. The assay detected VPAC positive cells in 98.6% of the patients having a PCa diagnosis, (N=141), and none (0%) of the males with benign prostatic hyperplasia (BPH) (N=10). Of the 56 “normal” patients, 62.5% (N=35, M=10, F=25) were negative for VPAC cells; 19.6% (N=11, M=11, F=0) had VPAC positive cells; and 17.8% (N=10, M=4, F=6) were uninterpretable due to excessive crystals in the urine. Although data are limited, the sensitivity of the assay was 99.3% with confidence interval of 96.1%–100% and the specificity was 100% with confidence interval of 69.2%–100%. Receptor blocking assay and FACS analyses demonstrated the presence of VPAC receptors and gene profiling examinations confirmed that the cells expressing VPAC receptors were malignant PCa cells. Conclusion These preliminary data are highly encouraging and warrant further evaluation of the assay to serve as a simple and reliable tool to detect PCa noninvasively. PMID:28075510
Ankle Brachial Index: simple non-invasive estimation of peripheral artery disease
NASA Astrophysics Data System (ADS)
Pieniak, Marcin; Cieślicki, Krzysztof; Żyliński, Marek; Górski, Piotr; Murgrabia, Agnieszka; Cybulski, Gerard
2014-11-01
According to international guidelines, patients with Peripheral Artery Disease (PAD) are burdened with high cardiovascular risk. One of the simplest, non-invasive methods for PAD detection is the ankle-brachial index (ABI) measurement. The ABI is calculated as the ratio of systolic blood pressure at the ankle (pressure in the posterior tibial artery or the dorsal artery) to the systolic pressure in the arm (in the brachial artery) when the body is in a horizontal position. The physiological value of the ABI is assumed to be between 1 and 1.3; however, these limits vary from study to study. A value less than 0.9 indicates PAD. Some authors propose also measuring the ABI on both sides of the body to highlight possible differences in blood pressure between the opposite arterial segments. The aim of this study was to perform a meta-analysis of the ABI diagnostic criteria used in different publications. Additionally, ABI measurements were performed on 19 healthy patients in age ranged from 20 to 63 years. The results showed a slight dependence between age and the differences between the values obtained from left and right sides of the body.
Comparison of three noninvasive methods for hemoglobin screening of blood donors.
Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S
2015-02-01
To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.
Nikooie, Roohollah; Gharakhanlo, Reza; Rajabi, Hamid; Bahraminegad, Morteza; Ghafari, Ali
2009-10-01
The purpose of this study was to determine the validity of noninvasive anaerobic threshold (AT) estimation using %SpO2 (arterial oxyhemoglobin saturation) changes and respiratory gas exchanges. Fifteen active, healthy males performed 2 graded exercise tests on a motor-driven treadmill in 2 separated sessions. Respiratory gas exchanges and heart rate (HR), lactate concentration, and %SpO2 were measured continuously throughout the test. Anaerobic threshold was determined based on blood lactate concentration (lactate-AT), %SpO2 changes (%SpO2-AT), respiratory exchange ratio (RER-AT), V-slope method (V-slope-AT), and ventilatory equivalent for O2 (EqO2-AT). Blood lactate measuring was considered as gold standard assessment of AT and was applied to confirm the validity of other noninvasive methods. The mean O2 corresponding to lactate-AT, %SpO2-AT, RER-AT, V-slope -AT, and EqO2-AT were 2176.6 +/- 206.4, 1909.5 +/- 221.4, 2141.2 +/- 245.6, 1933.7 +/- 216.4, and 1975 +/- 232.4, respectively. Intraclass correlation coefficient (ICC) analysis indicates a significant correlation between 4 noninvasive methods and the criterion method. Blond-Altman plots showed the good agreement between O2 corresponding to AT in each method and lactate-AT (95% confidence interval (CI). Our results indicate that a noninvasive and easy procedure of monitoring the %SpO2 is a valid method for estimation of AT. Also, in the present study, the respiratory exchange ratio (RER) method seemed to be the best respiratory index for noninvasive estimation of anaerobic threshold, and the heart rate corresponding to AT predicted by this method can be used by coaches and athletes to define training zones.
Emerging non-invasive Raman methods in process control and forensic applications.
Macleod, Neil A; Matousek, Pavel
2008-10-01
This article reviews emerging Raman techniques (Spatially Offset and Transmission Raman Spectroscopy) for non-invasive, sub-surface probing in process control and forensic applications. New capabilities offered by these methods are discussed and several application examples are given including the non-invasive detection of counterfeit drugs through blister packs and opaque plastic bottles and the rapid quantitative analysis of the bulk content of pharmaceutical tablets and capsules without sub-sampling.
Abdeyazdan, Zahra; Nematollahi, Monirosadat; Ghazavi, Zohreh; Mohhamadizadeh, Majid
2010-01-01
BACKGROUND: Since the use of high concentrations of oxygen in infants may lead to chronic lung problems, using proper methods of care in infants under mechanical ventilation is one of the most important measures in NICU. This study aimed to investigate the effects of prone and supine positions on oxygenation (SPO2) in premature infants under mechanical ventilation and comparing infants’ oxygenation in the two positions. METHODS: In across over non randomized clinical trial study, 32 preterm infants under mechanical ventilation who had inclusion criteria were enrolled in simple convenient method. Firstly, they were placed in supine position for 120 minutes and further in prone position for 120 minutes .Their SPO2 were monitored by pulse oximeter continuously and was recorded every minute. Data analysis was done using Software SPSS15 by ANOVA test and post hoc test. RESULTS: The data showed that during 120 minutes of exposure of infants in each position there were no significant changes in SPO2. In addition, the SPO2 levels in the prone position were significantly higher than the SPO2 levels in the supine position from 15th minute to 120th minute (to the end). CONCLUSIONS: Neonatal positioning in prone position is a simple, non-invasive, and free of charge method that could lead to improve oxygenation in infants undergoing mechanical ventilation. PMID:22049286
Sebastiani, Giada; Ghali, Peter; Wong, Philip; Klein, Marina B; Deschenes, Marc; Myers, Robert P
2014-01-01
OBJECTIVE: To determine practices among physicians in Canada for the assessment of liver fibrosis in patients with chronic liver diseases. METHODS: Hepatologists, gastroenterologists, infectious diseases specialists, members of the Canadian Gastroenterology Association and/or the Canadian HIV Trials Network who manage patients with liver diseases were invited to participate in a web-based, national survey. RESULTS: Of the 237 physicians invited, 104 (43.9%) completed the survey. Routine assessment of liver fibrosis was requested by the surveyed physicians mostly for chronic hepatitis C (76.5%), followed by autoimmune/cholestatic liver disease (59.6%) and chronic hepatitis B (52.9%). Liver biopsy was the main diagnostic tool for 46.2% of the respondents, Fibroscan (Echosens, France) for 39.4% and Fibrotest (LabCorp, USA) for 7.7%. Etiology-specific differences were observed: noninvasive methods were mostly used for hepatitis C (63% versus 37% liver biopsy) and hepatitis B (62.9% versus 37.1% liver biopsy). For 42.7% of respondents, the use of noninvasive methods reduced the need for liver biopsy by >50%. Physicians’ characteristics associated with higher use of noninvasive methods were older age and being based at a university hospital or in private practice versus community hospital. Physicians’ main concerns regarding noninvasive fibrosis assessment methods were access/availability (42.3%), lack of guidelines for clinical use (26.9%) and cost/lack of reimbursement (14.4%). CONCLUSIONS: Physicians who manage patients with chronic liver diseases in Canada require routine assessment of liver fibrosis stage. Although biopsy remains the primary diagnostic tool for almost one-half of respondents, noninvasive methods, particularly Fibroscan, have significantly reduced the need for liver biopsy in Canada. Limitations in access to and availability of the noninvasive methods represent a significant barrier. Finally, there is a need for clinical guidelines and a better reimbursement policy to implement noninvasive tools to assess liver fibrosis. PMID:24416739
Methodological dimensions of transcranial brain stimulation with the electrical current in human.
Rostami, Maryam; Golesorkhi, Mehrshad; Ekhtiari, Hamed
2013-01-01
Transcranial current stimulation (TCS) is a neuromodulation method in which the patient is exposed to a mild electric current (direct or alternating) at 1-2 mA, resulting in an increase or a decrease in the brain excitability. This modification in neural activities can be used as a method for functional human brain mapping with causal inferences. This method might also facilitate the treatments of many neuropsychiatric disorders based on its inexpensive, simple, safe, noninvasive, painless, semi-focal excitatory and inhibitory effects. Given this, a comparison amongst different brain stimulation modalities has been made to determine the potential advantages of the TCS method. In addition, considerable methodological details on using TCS in basic and clinical neuroscience studies in human subjects have been introduced. Technical characteristics of TCS devices and their related accessories with regard to safety concerns have also been well articulated. Finally, some TCS application opportunities have been emphasized, including its potential use in the near future.
Gaziano, Thomas A; Abrahams-Gessel, Shafika; Denman, Catalina A; Montano, Carlos Mendoza; Khanam, Masuma; Puoane, Thandi; Levitt, Naomi S
2016-01-01
Summary Background Cardiovascular disease contributes substantially to the non-communicable disease (NCD) burden in low-income and middle-income countries, which also often have substantial health personnel shortages. In this observational study we investigated whether community health workers could do community-based screenings to predict cardiovascular disease risk as effectively as could physicians or nurses, with a simple, non-invasive risk prediction indicator in low-income and middle-income countries. Methods This observation study was done in Bangladesh, Guatemala, Mexico, and South Africa. Each site recruited at least ten to 15 community health workers based on usual site-specific norms for required levels of education and language competency. Community health workers had to reside in the community where the screenings were done and had to be fluent in that community’s predominant language. These workers were trained to calculate an absolute cardiovascular disease risk score with a previously validated simple, non-invasive screening indicator. Community health workers who successfully finished the training screened community residents aged 35–74 years without a previous diagnosis of hypertension, diabetes, or heart disease. Health professionals independently generated a second risk score with the same instrument and the two sets of scores were compared for agreement. The primary endpoint of this study was the level of direct agreement between risk scores assigned by the community health workers and the health professionals. Findings Of 68 community health worker trainees recruited between June 4, 2012, and Feb 8, 2013, 42 were deemed qualified to do fieldwork (15 in Bangladesh, eight in Guatemala, nine in Mexico, and ten in South Africa). Across all sites, 4383 community members were approached for participation and 4049 completed screening. The mean level of agreement between the two sets of risk scores was 96 8% (weighted κ =0 948, 95% CI 0 936–0 961) and community health workers showed that 263 (6%) of 4049 people had a 5-year cardiovascular disease risk of greater than 20%. Interpretation Health workers without formal professional training can be adequately trained to effectively screen for, and identify, people at high risk of cardiovascular disease. Using community health workers for this screening would free up trained health professionals in low-resource settings to do tasks that need high levels of formal, professional training. Funding US National Heart, Lung, and Blood Institute and National Institutes of Health, UnitedHealth Chronic Disease Initiative. PMID:26187361
A factorial design experiment as a pilot study for noninvasive genetic sampling.
Renan, Sharon; Speyer, Edith; Shahar, Naama; Gueta, Tomer; Templeton, Alan R; Bar-David, Shirli
2012-11-01
Noninvasive genetic sampling has increasingly been used in ecological and conservation studies during the last decade. A major part of the noninvasive genetic literature is dedicated to the search for optimal protocols, by comparing different methods of collection, preservation and extraction of DNA from noninvasive materials. However, the lack of quantitative comparisons among these studies and the possibility that different methods are optimal for different systems make it difficult to decide which protocol to use. Moreover, most studies that have compared different methods focused on a single factor - collection, preservation or extraction - while there could be interactions between these factors. We designed a factorial experiment, as a pilot study, aimed at exploring the effect of several collection, preservation and extraction methods, and the interactions between them, on the quality and amplification success of DNA obtained from Asiatic wild ass (Equus hemionus) faeces in Israel. The amplification success rates of one mitochondrial DNA and four microsatellite markers differed substantially as a function of collection, preservation and extraction methods and their interactions. The most efficient combination for our system integrated the use of swabs as a collection method with preservation at -20 °C and with the Qiagen DNA Stool Kit with modifications as the DNA extraction method. The significant interaction found between the collection, preservation methods and the extraction methods reinforces the importance of conducting a factorial design experiment, rather than examining each factor separately, as a pilot study before initiating a full-scale noninvasive research project. © 2012 Blackwell Publishing Ltd.
Flint, Alexander C; Bhandari, Shiv G; Cullen, Sean P; Reddy, Adhikari V; Hsu, Daniel P; Rao, Vivek A; Patel, Minal; Pombra, Jasmeen; Edwards, Nancy J; Chan, Sheila L
2018-02-01
Large artery occlusion (LAO) in ischemic stroke requires recognition and triage to an endovascular stroke treatment center. Noninvasive LAO detection is needed to improve triage. Prospective study to test whether noninvasive cerebral oximetry can detect anterior circulation LAO in acute stroke. Interhemispheric ΔBrSO 2 in LAO was compared with controls. In LAO stroke, mean interhemispheric ΔBrSO 2 was -8.3±5.8% (n=19), compared with 0.4±5.8% in small artery stroke (n=17), 0.4±6.0% in hemorrhagic stroke (n=14), and 0.2±7.5% in subjects without stroke (n=19) ( P <0.001). Endovascular stroke treatment reduced the ΔBrSO 2 in most LAO subjects (16/19). Discrimination of LAO at a -3% ΔBrSO 2 cut had 84% sensitivity and 70% specificity. Addition of the G-FAST clinical score (gaze-face-arm-speech- time) to the BrSO 2 measure had 84% sensitivity and 90% specificity. Noninvasive cerebral oximetry may help detect LAO in ischemic stroke, particularly when combined with a simple clinical scoring system. © 2018 American Heart Association, Inc.
Misiulis, Edgaras; Džiugys, Algis; Navakas, Robertas; Striūgas, Nerijus
2017-05-01
Accurate and clinically safe measurements of intracranial pressure (ICP) are crucial for secondary brain damage prevention. There are two methods of ICP measurement: invasive and noninvasive. Invasive methods are clinically unsafe; therefore, safer noninvasive methods are being developed. One of the noninvasive ICP measurement methods implements the balance principle, which assumes that if the velocity of blood flow in both ophthalmic artery segments - the intracranial (IOA) and extracranial (EOA) - is equal, then the acting ICP on the IOA and the external pressure (Pe) on the EOA are also equal. To investigate the assumption of the balance principle, a generalized computational model incorporating a fluid-structure interaction (FSI) module was created and used to simulate noninvasive ICP measurement by accounting for the time-dependent behavior of the elastic internal carotid (ICA) and ophthalmic (OA) arteries and their interaction with pulsatile blood flow. It was found that the extra balance pressure term, which incorporates the hydrodynamic pressure drop between measurement points, must be added into the balance equation, and the corrections on a difference between the velocity of blood flow in the IOA and EOA must be made, due to a difference in the blood flow rate. Copyright © 2017 Elsevier Ltd. All rights reserved.
Tan, Xia; Ji, Zhong; Zhang, Yadan
2018-04-25
Non-invasive continuous blood pressure monitoring can provide an important reference and guidance for doctors wishing to analyze the physiological and pathological status of patients and to prevent and diagnose cardiovascular diseases in the clinical setting. Therefore, it is very important to explore a more accurate method of non-invasive continuous blood pressure measurement. To address the shortcomings of existing blood pressure measurement models based on pulse wave transit time or pulse wave parameters, a new method of non-invasive continuous blood pressure measurement - the GA-MIV-BP neural network model - is presented. The mean impact value (MIV) method is used to select the factors that greatly influence blood pressure from the extracted pulse wave transit time and pulse wave parameters. These factors are used as inputs, and the actual blood pressure values as outputs, to train the BP neural network model. The individual parameters are then optimized using a genetic algorithm (GA) to establish the GA-MIV-BP neural network model. Bland-Altman consistency analysis indicated that the measured and predicted blood pressure values were consistent and interchangeable. Therefore, this algorithm is of great significance to promote the clinical application of a non-invasive continuous blood pressure monitoring method.
Isotope-selective sensor for medical diagnostics based on PAS
NASA Astrophysics Data System (ADS)
Wolff, M.; Groninga, H. G.; Harde, H.
2005-06-01
Development of new optical sensor technologies has a major impact on the progression of diagnostic methods. Of the permanently increasing number of non-invasive 13C-breath tests, the Urea Breath Test for detection of Helicobacter pylori is the most prominent. However, many recent developments go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up based on Photoacoustic Spectroscopy. Using a wavelength-modulated DFB-diode laser and taking advantage of acoustical resonances of the sample cell, we performed very sensitive isotope-selective measurements on CO2. Detection limits for 13CO2 of a few ppm and for the variation of the 13CO2 concentration of approximately 1% were achieved.
Ultrasound diagnosis of penile fracture.
Nomura, Jason T; Sierzenski, Paul R
2010-04-01
Rupture of the corpus cavernosum, penile fracture, is an uncommon occurrence. Diagnosis is straightforward when classical historical and physical examination findings are present. However, atypical presentations can make the diagnosis difficult. Review the literature supporting use of ultrasound for the diagnosis of penile fracture. Review of the ultrasonographic findings in patients with penile fracture. A 32-year-old man presented with penile ecchymosis after sex but lacking several historical and physical examination elements for a diagnosis of penile fracture. Ultrasound performed by the treating physician revealed rupture of the tunica albuginea and presence of a hematoma, leading to a diagnosis of penile fracture. Ultrasound is a simple, efficient, and non-invasive imaging method to assist in the diagnosis of penile fracture. Copyright 2010 Elsevier Inc. All rights reserved.
Percutaneous dermal drug delivery for local pain control
Tadicherla, Sujatha; Berman, Brian
2006-01-01
Topical anesthetics have evolved from a simple solution of cocaine to creams, ointments, gels, liposomal preparations, and to the latest sophisticated patches and peels. Topical anesthetics are essential for performing diagnostic, therapeutic, and cosmetic dermatology procedures. These anesthetics noninvasively deliver anesthesia in locally required areas. In this review, we present an overview on the mechanism of precutaneous absorption of skin and address the composition, duration of onset of anesthetic effect, uses, and side effects that are applicable for the products. Also discussed are the novel advances of using heat to enhance penetration of the anesthetic as seen in Synera™ patch and delivery of anesthesia using a peel method as seen in the yet to be US Food and Drug Administration-approved S-Caine peel. PMID:18360585
Dudley, Emily S; Grunden, Beverly K; Crocker, Conan; Boivin, Gregory P
2013-10-22
Both wild and laboratory strains of the musk shrew (Suncus murinus) have a high incidence of periodontitis. The authors completed necropsy examinations in 51 shrews to identify dental lesions including tooth loss, mobility and fractures. Dental lesions were identified in significantly more females than males, and older animals were more likely to have lesions present. Shrews with one or more dental lesions weighed significantly less than those without lesions present. Dietary supplementation with mealworms did not significantly affect the incidence of dental lesions or the body weight of male or female shrews. The authors recommend routine body weight measurement as a simple, noninvasive method of detecting shrews with an increased likelihood of having dental lesions.
Ruta, J; Strumiłło, P
2001-01-01
T-wave alternans (TWA) at microvolt level is considered as an important non-invasive risk factor for sudden death. Several methods are used to measure such repolarization variations, but each of them has some limitations. The purpose of our study is to assess the usefulness of Poincaré maps, a method based on nonlinear dynamics theory, in detection of repolarization abnormalities. In 30 postinfarction patients presence of TWA in precordial ECG leads was assessed by the spectral method (SM) and by the Poincaré maps (PM). Quantitative measures of both methods: alternans voltage (AV) and alternans distance (AD) were compared using linear regression. Significant correlation between both measures (r = 0.92, p < 0.01) was found. The value of AD > or = 10 microV was accepted as significant for the presence of T-wave alternans. Poincaré mapping seems to be a useful and simple method for detection of TWA. The alternans distance equal or greater than 10 microV can be considered as a level determinative for the presence of TWA.
A review on the non-invasive evaluation of skeletal muscle oxygenation
NASA Astrophysics Data System (ADS)
Halim, A. A. A.; Laili, M. H.; Aziz, N. A.; Laili, A. R.; Salikin, M. S.; Rusop, M.
2016-07-01
The aim of this review is to conduct a feasibility study of non-invasive evaluation in skeletal muscle oxygenation. This non-invasive evaluation could extract many information using a safe non-invasive method regarding to the oxygenation and microcirculation status in human blood muscle. This brief review highlights the progress of the application of NIRS to evaluate skeletal muscle oxygenation in various activity of human nature from the historical point of view to the present advancement. Since the discovery of non-invasive optical method during 1992, there are many non-invasive techniques uses optical properties on human subject such as near infrared spectroscopy NIRS, optical topography, functional near infrared spectroscopy fNIRS and imaging fNIRI. Furthermore, in this paper we discuss the light absorption potential (LAP) towards chromophores content inside human muscle. Modified beer lambert law was studied in order to build a better understanding toward LAP between chromophores under tissue multilayers in human muscle. This paper will describe the NIRS principle and the basis for its proposed used in skeletal muscle oxygenation. This will cover the advantages and limitation of such application. Thus, these non-invasive techniques could open other possibilities to study muscle performance diagnosis.
Introducing Human Population Biology through an Easy Laboratory Exercise on Mitochondrial DNA
ERIC Educational Resources Information Center
Pardinas, Antonio F.; Dopico, Eduardo; Roca, Agustin; Garcia-Vazquez, Eva; Lopez, Belen
2010-01-01
This article describes an easy and cheap laboratory exercise for students to discover their own mitochondrial haplogroup. Students use buccal swabs to obtain mucosa cells as noninvasive tissue samples, extract DNA, and with a simple polymerase chain reaction-restriction fragment length polymorphism analysis they can obtain DNA fragments of…
NASA Astrophysics Data System (ADS)
Lancaster, Gemma; Stefanovska, Aneta; Pesce, Margherita; Marco Vezzoni, Gian; Loggini, Barbara; Pingitore, Raffaele; Ghiara, Fabrizio; Barachini, Paolo; Cervadoro, Gregorio; Romanelli, Marco; Rossi, Marco
2015-08-01
Skin malignant melanoma is a highly angiogenic cancer, necessitating early diagnosis for positive prognosis. The current diagnostic standard of biopsy and histological examination inevitably leads to many unnecessary invasive excisions. Here, we propose a non-invasive method of identification of melanoma based on blood flow dynamics. We consider a wide frequency range from 0.005-2 Hz associated with both local vascular regulation and effects of cardiac pulsation. Combining uniquely the power of oscillations associated with individual physiological processes we obtain a marker which distinguishes between melanoma and atypical nevi with sensitivity of 100% and specificity of 90.9%. The method reveals valuable functional information about the melanoma microenvironment. It also provides the means for simple, accurate, in vivo distinction between malignant melanoma and atypical nevi, and may lead to a substantial reduction in the number of biopsies currently undertaken.
Liquid crystal thermography and true-colour digital image processing
NASA Astrophysics Data System (ADS)
Stasiek, J.; Stasiek, A.; Jewartowski, M.; Collins, M. W.
2006-06-01
In the last decade thermochromic liquid crystals (TLC) and true-colour digital image processing have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. Thin coatings of TLCs at surfaces are utilized to obtain detailed temperature distributions and heat transfer rates for steady or transient processes. Liquid crystals also can be used to make visible the temperature and velocity fields in liquids by the simple expedient of directly mixing the liquid crystal material into the liquid (water, glycerol, glycol, and silicone oils) in very small quantities to use as thermal and hydrodynamic tracers. In biomedical situations e.g., skin diseases, breast cancer, blood circulation and other medical application, TLC and image processing are successfully used as an additional non-invasive diagnostic method especially useful for screening large groups of potential patients. The history of this technique is reviewed, principal methods and tools are described and some examples are also presented.
Microneedle and mucosal delivery of influenza vaccines
Kang, Sang-Moo; Song, Jae-Min; Kim, Yeu-Chun
2017-01-01
In recent years with the threat of pandemic influenza and other public health needs, alternative vaccination methods other than intramuscular immunization have received great attention. The skin and mucosal surfaces are attractive sites probably because of both non-invasive access to the vaccine delivery and unique immunological responses. Intradermal vaccines using a microinjection system (BD Soluvia) and intranasal vaccines (FluMist) are licensed. As a new vaccination method, solid microneedles have been developed using a simple device that may be suitable for self-administration. Because coated micorneedle influenza vaccines are administered in the solid state, developing formulations maintaining the stability of influenza vaccines is an important issue to be considered. Marketable microneedle devices and clinical trials remain to be developed. Other alternative mucosal routes such as oral and intranasal delivery systems are also attractive for inducing cross protective mucosal immunity but effective non-live mucosal vaccines remain to be developed. PMID:22697052
Single molecule targeted sequencing for cancer gene mutation detection.
Gao, Yan; Deng, Liwei; Yan, Qin; Gao, Yongqian; Wu, Zengding; Cai, Jinsen; Ji, Daorui; Li, Gailing; Wu, Ping; Jin, Huan; Zhao, Luyang; Liu, Song; Ge, Liangjin; Deem, Michael W; He, Jiankui
2016-05-19
With the rapid decline in cost of sequencing, it is now affordable to examine multiple genes in a single disease-targeted clinical test using next generation sequencing. Current targeted sequencing methods require a separate step of targeted capture enrichment during sample preparation before sequencing. Although there are fast sample preparation methods available in market, the library preparation process is still relatively complicated for physicians to use routinely. Here, we introduced an amplification-free Single Molecule Targeted Sequencing (SMTS) technology, which combined targeted capture and sequencing in one step. We demonstrated that this technology can detect low-frequency mutations using artificially synthesized DNA sample. SMTS has several potential advantages, including simple sample preparation thus no biases and errors are introduced by PCR reaction. SMTS has the potential to be an easy and quick sequencing technology for clinical diagnosis such as cancer gene mutation detection, infectious disease detection, inherited condition screening and noninvasive prenatal diagnosis.
Ku, Warren W; Pagliusi, Frank; Foley, George; Roesler, Alfred; Zimmerman, Thomas
2010-01-01
The identification and use of mature male non-human primates in nonclinical toxicology studies could be important for evaluating candidate drugs for which the profile of toxicity may differ depending on sexual maturity. This investigation sought to establish operational criteria to complement the current standard of histological evaluation for defining sexual maturity in male cynomolgus monkeys (Macaca fascicularis) used for toxicology studies, and to identify a practical non-invasive measure to select mature males for study. Retrospectively, the relationships between body weight, testicular weight and testis histology were established in control males (n=126) used in previous toxicology studies. Prospectively, testicular volumes were measured in-life by orchidometry using comparative scrotal palpation (n=23 males used for study), then compared to testicular weights measured at necropsy. Consistent with previous literature, a weak relationship was observed between body weight and testicular weight. There was, however, a very good relationship between testicular weight and histological maturation level, which was based upon microscopic examination of testes, epididymides and prostates. Orchidometric measurement of testicular volume was found to be a reasonable predictor of testicular weight and served to rapidly select sexually mature males for study, and a total testicular volume (left and right combined) of >20 ml correlated with the histological appearance of maturity. Based upon this preliminary exploratory study, the initial simple measurement of testicular volume by orchidometry may provide a non-invasive alternative approach for assessing the sexual maturity of male cynomolgus monkeys in research colonies or during toxicology studies that will require more thorough validation. Copyright 2009 Elsevier Inc. All rights reserved.
Breveglieri, Giulia; Travan, Anna; D’Aversa, Elisabetta; Cosenza, Lucia Carmela; Pellegatti, Patrizia; Guerra, Giovanni; Gambari, Roberto
2017-01-01
The β-thalassemias are genetic disorder caused by more than 200 mutations in the β-globin gene, resulting in a total (β0) or partial (β+) deficit of the globin chain synthesis. The most frequent Mediterranean mutations for β-thalassemia are: β039, β+IVSI-110, β+IVSI-6 and β0IVSI-1. Several molecular techniques for the detection of point mutations have been developed based on the amplification of the DNA target by polymerase chain reaction (PCR), but they could be labor-intensive and technically demanding. On the contrary, TaqMan® genotyping assays are a simple, sensitive and versatile method suitable for the single nucleotide polymorphism (SNP) genotyping affecting the human β-globin gene. Four TaqMan® genotyping assays for the most common β-thalassemia mutations present in the Mediterranean area were designed and validated for the genotype characterization of genomic DNA extracted from 94 subjects comprising 25 healthy donors, 33 healthy carriers and 36 β-thalassemia patients. In addition, 15 specimens at late gestation (21–39 gestational weeks) and 11 at early gestation (5–18 gestational weeks) were collected from pregnant women, and circulating cell-free fetal DNAs were extracted and analyzed with these four genotyping assays. We developed four simple, inexpensive and versatile genotyping assays for the postnatal and prenatal identification of the thalassemia mutations β039, β+IVSI-110, β+IVSI-6, β0IVSI-1. These genotyping assays are able to detect paternally inherited point mutations in the fetus and could be efficiently employed for non-invasive prenatal diagnosis of β-globin gene mutations, starting from the 9th gestational week. PMID:28235086
NASA Astrophysics Data System (ADS)
Reich, Marvin; Mikolaj, Michal; Blume, Theresa; Güntner, Andreas
2017-04-01
Hydrological process research at the plot to catchment scale commonly involves invasive field methods, leading to a large amount of point data. A promising alternative, which gained increasing interest in the hydrological community over the last years, is gravimetry. The combination of its non-invasive and integrative nature opens up new possibilities to approach hydrological process research. In this study we combine a field-scale sprinkling experiment with continuous superconducting gravity (SG) measurements. The experimental design consists of 8 sprinkler units, arranged symmetrically within a radius of about ten meters around an iGrav (SG) in a field enclosure. The gravity signal of the infiltrating sprinkling water is analyzed using a simple 3D water mass distribution model. We first conducted a number of virtual sprinkling experiments resulting in different idealized infiltration patterns and determined the pattern specific gravity response. In a next step we determined which combination of idealized infiltration patterns was able to reproduce the gravity response of our real-world experiment at the Wettzell Observatory (Germany). This process hypothesis is then evaluated with measured point-scale soil moisture responses and the results of the time-lapse electric resistivity survey which was carried out during the sprinkling experiment. This study demonstrates that a controlled sprinkling experiment around a gravimeter in combination with a simple infiltration model is sufficient to identify subsurface flow patterns and thus the dominant infiltration processes. As gravimeters become more portable and can actually be deployed in the field, their combination with sprinkling experiments as shown here constitutes a promising possibility to investigate hydrological processes in a non-invasive way.
van den Oever, Jessica M E; van Minderhout, Ivonne J H M; Harteveld, Cornelis L; den Hollander, Nicolette S; Bakker, Egbert; van der Stoep, Nienke; Boon, Elles M J
2015-09-01
The challenge in noninvasive prenatal diagnosis for monogenic disorders lies in the detection of low levels of fetal variants in the excess of maternal cell-free plasma DNA. Next-generation sequencing, which is the main method used for noninvasive prenatal testing and diagnosis, can overcome this challenge. However, this method may not be accessible to all genetic laboratories. Moreover, shotgun next-generation sequencing as, for instance, currently applied for noninvasive fetal trisomy screening may not be suitable for the detection of inherited mutations. We have developed a sensitive, mutation-specific, and fast alternative for next-generation sequencing-mediated noninvasive prenatal diagnosis using a PCR-based method. For this proof-of-principle study, noninvasive fetal paternally inherited mutation detection was performed using cell-free DNA from maternal plasma. Preferential amplification of the paternally inherited allele was accomplished through a personalized approach using a blocking probe against maternal sequences in a high-resolution melting curve analysis-based assay. Enhanced detection of the fetal paternally inherited mutation was obtained for both an autosomal dominant and a recessive monogenic disorder by blocking the amplification of maternal sequences in maternal plasma. Copyright © 2015 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Haga, Sei; Morioka, Takato; Shimogawa, Takafumi; Akiyama, Tomoaki; Murao, Kei; Kanazawa, Yuka; Sayama, Tetsuro; Arakawa, Shuji
2016-01-01
Perfusion magnetic resonance image with arterial spin labeling (ASL) provides a completely noninvasive measurement of cerebral blood flow (CBF). However, arterial transient times can have a marked effect on the ASL signal. For example, a single postlabeling delay (PLD) of 1.5 seconds underestimates the slowly streaming collateral pathways that maintain the cerebrovascular reserve (CVR). To overcome this limitation, we developed a dual PLD method. A dual PLD method of 1.5 and 2.5 seconds was compared with (123)I-iodoamphetamine single-photon emission computed tomography with acetazolamide loading to assess CVR in 10 patients with steno-occlusive cerebrovascular disease. In 5 cases (Group A), dual PLD-ASL demonstrated low CBF with 1.5-second PLD in the target area, whereas CBF was improved with 2.5-second PLD. In the other 5 cases (Group B), dual PLD-ASL depicted low CBF with 1.5-second PLD, and no improvement in CBF with 2.5-second PLD in the target area was observed. On single-photon emission computed tomography, CVR was maintained in Group A but decreased in Group B. Although dual PLD methods may not be a completely alternative test for (123)I-iodoamphetamine single-photon emission computed tomography with acetazolamide loading, it is a feasible, simple, noninvasive, and repeatable technique for assessing CVR, even when employed in a routine clinical setting. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando
2017-01-01
Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.
Estimation of body-size traits by photogrammetry in large mammals to inform conservation.
Berger, Joel
2012-10-01
Photography, including remote imagery and camera traps, has contributed substantially to conservation. However, the potential to use photography to understand demography and inform policy is limited. To have practical value, remote assessments must be reasonably accurate and widely deployable. Prior efforts to develop noninvasive methods of estimating trait size have been motivated by a desire to answer evolutionary questions, measure physiological growth, or, in the case of illegal trade, assess economics of horn sizes; but rarely have such methods been directed at conservation. Here I demonstrate a simple, noninvasive photographic technique and address how knowledge of values of individual-specific metrics bears on conservation policy. I used 10 years of data on juvenile moose (Alces alces) to examine whether body size and probability of survival are positively correlated in cold climates. I investigated whether the presence of mothers improved juvenile survival. The posited latter relation is relevant to policy because harvest of adult females has been permitted in some Canadian and American jurisdictions under the assumption that probability of survival of young is independent of maternal presence. The accuracy of estimates of head sizes made from photographs exceeded 98%. The estimates revealed that overwinter juvenile survival had no relation to the juvenile's estimated mass (p < 0.64) and was more strongly associated with maternal presence (p < 0.02) than winter snow depth (p < 0.18). These findings highlight the effects on survival of a social dynamic (the mother-young association) rather than body size and suggest a change in harvest policy will increase survival. Furthermore, photographic imaging of growth of individual juvenile muskoxen (Ovibos moschatus) over 3 Arctic winters revealed annual variability in size, which supports the idea that noninvasive monitoring may allow one to detect how some environmental conditions ultimately affect body growth. ©2012 Society for Conservation Biology.
Non-Invasive Methods for Iron Concentration Assessment
NASA Astrophysics Data System (ADS)
Carneiro, Antonio A. O.; Baffa, Oswaldo; Angulo, Ivan L.; Covas, Dimas T.
2002-08-01
Iron excess is commonly observed in patients with transfusional iron overload. The iron chelation therapy in these patients require accurate determination of the magnitude of iron excess. The most promising method for noninvasive assessment of iron stores is based on measurements of hepatic magnetic susceptibility.
Method and apparatus for dynamic focusing of ultrasound energy
Candy, James V.
2002-01-01
Method and system disclosed herein include noninvasively detecting, separating and destroying multiple masses (tumors, cysts, etc.) through a plurality of iterations from tissue (e.g., breast tissue). The method and system may open new frontiers with the implication of noninvasive treatment of masses in the biomedical area along with the expanding technology of acoustic surgery.
Photoacoustic sensor for medical diagnostics
NASA Astrophysics Data System (ADS)
Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann
2004-03-01
The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.
Can we recognize horses by their ocular biometric traits using deep convolutional neural networks?
NASA Astrophysics Data System (ADS)
Trokielewicz, Mateusz; Szadkowski, Mateusz
2017-08-01
This paper aims at determining the viability of horse recognition by the means of ocular biometrics and deep convolutional neural networks (deep CNNs). Fast and accurate identification of race horses before racing is crucial for ensuring that exactly the horses that were declared are participating, using methods that are non-invasive and friendly to these delicate animals. As typical iris recognition methods require lot of fine-tuning of the method parameters and high-quality data, CNNs seem like a natural candidate to be applied for recognition thanks to their potentially excellent abilities in describing texture, combined with ease of implementation in an end-to-end manner. Also, with such approach we can easily utilize both iris and periocular features without constructing complicated algorithms for each. We thus present a simple CNN classifier, able to correctly identify almost 80% of the samples in an identification scenario, and give equal error rate (EER) of less than 10% in a verification scenario.
Thandassery, Ragesh B; Al Kaabi, Saad; Soofi, Madiha E; Mohiuddin, Syed A; John, Anil K; Al Mohannadi, Muneera; Al Ejji, Khalid; Yakoob, Rafie; Derbala, Moutaz F; Wani, Hamidullah; Sharma, Manik; Al Dweik, Nazeeh; Butt, Mohammed T; Kamel, Yasser M; Sultan, Khaleel; Pasic, Fuad; Singh, Rajvir
2016-07-01
Many indirect noninvasive scores to predict liver fibrosis are calculated from routine blood investigations. Only limited studies have compared their efficacy head to head. We aimed to compare these scores with liver biopsy fibrosis stages in patients with chronic hepatitis C. From blood investigations of 1602 patients with chronic hepatitis C who underwent a liver biopsy before initiation of antiviral treatment, 19 simple noninvasive scores were calculated. The area under the receiver operating characteristic curves and diagnostic accuracy of each of these scores were calculated (with reference to the Scheuer staging) and compared. The mean age of the patients was 41.8±9.6 years (1365 men). The most common genotype was genotype 4 (65.6%). Significant fibrosis, advanced fibrosis, and cirrhosis were seen in 65.1%, 25.6, and 6.6% of patients, respectively. All the scores except the aspartate transaminase (AST) alanine transaminase ratio, Pohl score, mean platelet volume, fibro-alpha, and red cell distribution width to platelet count ratio index showed high predictive accuracy for the stages of fibrosis. King's score (cutoff, 17.5) showed the highest predictive accuracy for significant and advanced fibrosis. King's score, Göteborg university cirrhosis index, APRI (the AST/platelet count ratio index), and Fibrosis-4 (FIB-4) had the highest predictive accuracy for cirrhosis, with the APRI (cutoff, 2) and FIB-4 (cutoff, 3.25) showing the highest diagnostic accuracy.We derived the study score 8.5 - 0.2(albumin, g/dL) +0.01(AST, IU/L) -0.02(platelet count, 10/L), which at a cutoff of >4.7 had a predictive accuracy of 0.868 (95% confidence interval, 0.833-0.904) for cirrhosis. King's score for significant and advanced fibrosis and the APRI or FIB-4 score for cirrhosis could be the best simple indirect noninvasive scores.
Targeted, noninvasive blockade of cortical neuronal activity
NASA Astrophysics Data System (ADS)
McDannold, Nathan; Zhang, Yongzhi; Power, Chanikarn; Arvanitis, Costas D.; Vykhodtseva, Natalia; Livingstone, Margaret
2015-11-01
Here we describe a novel method to noninvasively modulate targeted brain areas through the temporary disruption of the blood-brain barrier (BBB) via focused ultrasound, enabling focal delivery of a neuroactive substance. Ultrasound was used to locally disrupt the BBB in rat somatosensory cortex, and intravenous administration of GABA then produced a dose-dependent suppression of somatosensory-evoked potentials in response to electrical stimulation of the sciatic nerve. No suppression was observed 1-5 days afterwards or in control animals where the BBB was not disrupted. This method has several advantages over existing techniques: it is noninvasive; it is repeatable via additional GABA injections; multiple brain regions can be affected simultaneously; suppression magnitude can be titrated by GABA dose; and the method can be used with freely behaving subjects. We anticipate that the application of neuroactive substances in this way will be a useful tool for noninvasively mapping brain function, and potentially for surgical planning or novel therapies.
Non-invasive Assessments of Adipose Tissue Metabolism In Vitro.
Abbott, Rosalyn D; Borowsky, Francis E; Quinn, Kyle P; Bernstein, David L; Georgakoudi, Irene; Kaplan, David L
2016-03-01
Adipose tissue engineering is a diverse area of research where the developed tissues can be used to study normal adipose tissue functions, create disease models in vitro, and replace soft tissue defects in vivo. Increasing attention has been focused on the highly specialized metabolic pathways that regulate energy storage and release in adipose tissues which affect local and systemic outcomes. Non-invasive, dynamic measurement systems are useful to track these metabolic pathways in the same tissue model over time to evaluate long term cell growth, differentiation, and development within tissue engineering constructs. This approach reduces costs and time in comparison to more traditional destructive methods such as biochemical and immunochemistry assays and proteomics assessments. Towards this goal, this review will focus on important metabolic functions of adipose tissues and strategies to evaluate them with non-invasive in vitro methods. Current non-invasive methods, such as measuring key metabolic markers and endogenous contrast imaging will be explored.
Non-invasive assessments of adipose tissue metabolism in vitro
Abbott, Rosalyn D.; Borowsky, Francis E.; Quinn, Kyle P.; Bernstein, David L.; Georgakoudi, Irene; Kaplan, David L.
2015-01-01
Adipose tissue engineering is a diverse area of research where the developed tissues can be used to study normal adipose tissue functions, create disease models in vitro, and replace soft tissue defects in vivo. Increasing attention has been focused on the highly specialized metabolic pathways that regulate energy storage and release in adipose tissues which affect local and systemic outcomes. Non-invasive, dynamic measurement systems are useful to track these metabolic pathways in the same tissue model over time to evaluate long term cell growth, differentiation, and development within tissue engineering constructs. This approach reduces costs and time in comparison to more traditional destructive methods such as biochemical and immunochemistry assays and proteomics assessments. Towards this goal, this review will focus on important metabolic functions of adipose tissues and strategies to evaluate them with noninvasive in vitro methods. Current non-invasive methods, such as measuring key metabolic markers and endogenous contrast imaging will be explored. PMID:26399988
New approaches in the rehabilitation of the traumatic high level quadriplegic.
Bach, J R
1991-02-01
The use of noninvasive alternatives to tracheostomy for ventilatory support have been described in the patient management of various neuromuscular disorders. The use of these techniques for patients with traumatic high level quadriplegia, however, is hampered by the resort to tracheostomy in the acute hospital setting. Twenty traumatic high level quadriplegic patients on intermittent positive pressure ventilation (IPPV) via tracheostomy with little or no ability for unassisted breathing were converted to noninvasive ventilatory support methods and had their tracheostomy sites closed. Four additional patients were ventilated by noninvasive methods without tracheostomy. These methods included the use of body ventilators and the noninvasive intermittent positive airway pressure alternatives of IPPV via the mouth, nose, or custom acrylic strapless oral-nasal interface (SONI). Overnight end-tidal pCO2 studies and monitoring of oxyhemoglobin saturation (SaO2) were used to adjust ventilator volumes and to document effective ventilation during sleep. No significant complications have resulted from the use of these methods over a period of 45 patient-years. Elimination of the tracheostomy permitted significant free time by glossopharyngeal breathing for four patients, two of whom had no measurable vital capacity. We conclude that noninvasive ventilatory support alternatives can be effective and deserve further study in this patient population.
Boenzi, Sara; Deodato, Federica; Taurisano, Roberta; Martinelli, Diego; Verrigni, Daniela; Carrozzo, Rosalba; Bertini, Enrico; Pastore, Anna; Dionisi-Vici, Carlo; Johnson, David W
2014-11-01
Two oxysterols, cholestan-3β,5α,6β-triol (C-triol) and 7-ketocholesterol (7-KC), have been recently proposed as diagnostic markers of Niemann-Pick type C (NP-C) disease, representing a potential alternative diagnostic tool to the more invasive and time consuming filipin test in cultured fibroblasts. Usually, the oxysterols are detected and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using atmospheric pressure chemical ionization (APCI) or electro-spray-ionization (ESI) sources, after a variety of derivatization procedures to enhance sensitivity. We developed a sensitive LC-MS/MS method to quantify the oxysterols in plasma as dimethylaminobutyrate ester, suitable for ESI analysis. This method, with an easy liquid-phase extraction and a short derivatization procedure, has been validated to demonstrate specificity, linearity, recovery, lowest limit of quantification, accuracy and precision. The assay was linear over a concentration range of 0.5-200ng/mL for C-triol and 1.0-200ng/mL for 7-KC. Intra-day and inter-day coefficients of variation (CV%) were <15% for both metabolites. Receiver operating characteristic analysis estimates that the area under curve was 0.998 for C-triol, and 0.972 for 7-KC, implying a significant discriminatory power for the method in this patient population of both oxysterols. In summary, our method provides a simple, rapid and non-invasive diagnostic tool for the biochemical diagnosis of NP-C disease. Copyright © 2014 Elsevier B.V. All rights reserved.
Disentangling High Fat, Low Carb, and Healthy Aging.
Brown-Borg, Holly M
2017-09-05
Dietary interventions are simple, non-invasive tools that can be utilized to improve health and lifespan. In this issue, Roberts et al. (2017) and Newman et al. (2017) reveal the physiological benefits of feeding mice ketogenic diets and suggest different underlying mechanisms that may promote healthy aging. Copyright © 2017 Elsevier Inc. All rights reserved.
Low-Intensity Vibration as a Treatment for Traumatic Muscle Injury
2015-08-01
improving muscle healing, thereby reducing joint stiffness and increasing mobility of polytrauma patients. 15. SUBJECT TERMS Skeletal muscle repair...mobility of polytrauma patients. 2. KEYWORDS Skeletal muscle repair, low-intensity vibration, monocytes/macrophages, endothelial precursor cells...innovative, non-invasive and simple treatment for improving muscle healing and thereby reducing joint stiffness and increasing mobility of polytrauma
Non-invasive method of measuring cerebral spinal fluid pressure
NASA Technical Reports Server (NTRS)
Borchert, Mark S. (Inventor); Lambert, James L. (Inventor)
2000-01-01
The invention provides a method of non-invasively determining intracranial pressure from measurements of an eye. A parameter of an optic nerve of the eye is determined, along with an intraocular pressure of the eye. The intracranial pressure may be determined from the intraocular pressure and the parameter.
Oskooei, Ali; Kaigala, Govind V
2017-06-01
We present a method for nonintrusive localization and reagent delivery on immersed biological samples with topographical variation on the order of hundreds of micrometers. Our technique, which we refer to as the deep-reaching hydrodynamic flow confinement (DR-HFC), is simple and passive: it relies on a deep-reaching hydrodynamic confinement delivered through a simple microfluidic probe design to perform localized microscale alterations on substrates as deep as 600 μm. Designed to scan centimeter-scale areas of biological substrates, our method passively prevents sample intrusion by maintaining a large gap between the probe and the substrate. The gap prevents collision of the probe and the substrate and reduces the shear stress experienced by the sample. We present two probe designs: linear and annular DR-HFC. Both designs comprise a reagent-injection aperture and aspiration apertures that serve to confine the reagent. We identify the design parameters affecting reagent localization and depth by DR-HFC and study their individual influence on the operation of DR-HFC numerically. Using DR-HFC, we demonstrate localized binding of antihuman immunoglobulin G (IgG) onto an activated substrate at various depths from 50 to 600 μm. DR-HFC provides a readily implementable approach for noninvasive processing of biological samples applicable to the next generation of diagnostic and bioanalytical devices.
Radiologic evaluation of nonalcoholic fatty liver disease
Lee, Seung Soo; Park, Seong Ho
2014-01-01
Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609
Budischak, Sarah A; Hoberg, Eric P; Abrams, Art; Jolles, Anna E; Ezenwa, Vanessa O
2015-09-01
Most hosts are concurrently or sequentially infected with multiple parasites; thus, fully understanding interactions between individual parasite species and their hosts depends on accurate characterization of the parasite community. For parasitic nematodes, noninvasive methods for obtaining quantitative, species-specific infection data in wildlife are often unreliable. Consequently, characterization of gastrointestinal nematode communities of wild hosts has largely relied on lethal sampling to isolate and enumerate adult worms directly from the tissues of dead hosts. The necessity of lethal sampling severely restricts the host species that can be studied, the adequacy of sample sizes to assess diversity, the geographic scope of collections and the research questions that can be addressed. Focusing on gastrointestinal nematodes of wild African buffalo, we evaluated whether accurate characterization of nematode communities could be made using a noninvasive technique that combined conventional parasitological approaches with molecular barcoding. To establish the reliability of this new method, we compared estimates of gastrointestinal nematode abundance, prevalence, richness and community composition derived from lethal sampling with estimates derived from our noninvasive approach. Our noninvasive technique accurately estimated total and species-specific worm abundances, as well as worm prevalence and community composition when compared to the lethal sampling method. Importantly, the rate of parasite species discovery was similar for both methods, and only a modest number of barcoded larvae (n = 10) were needed to capture key aspects of parasite community composition. Overall, this new noninvasive strategy offers numerous advantages over lethal sampling methods for studying nematode-host interactions in wildlife and can readily be applied to a range of study systems. © 2015 John Wiley & Sons Ltd.
Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya
2018-01-01
Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.
Fibrosis Assessment in Nonalcoholic Fatty Liver Disease (NAFLD) in 2016.
Kaswala, Dharmesh H; Lai, Michelle; Afdhal, Nezam H
2016-05-01
Nonalcoholic fatty liver disease (NAFLD) is a spectrum of liver pathologies characterized by hepatic steatosis with a history of little to no alcohol consumption or secondary causes of hepatic steatosis. The prevalence of NAFLD is 20-25 % of the general population in the Western countries and is associated with metabolic risk factors such as obesity, diabetes mellitus, and dyslipidemia. The spectrum of disease ranges from simple steatosis to nonalcoholic steatohepatitis, fibrosis, and cirrhosis. Advanced fibrosis is the most significant predictor of mortality in NAFLD. It is crucial to assess for the presence and degree of hepatic fibrosis in order to make therapeutic decisions and predict clinical outcomes. Liver biopsy, the current gold standard to assess the liver fibrosis, has a number of drawbacks such as invasiveness, sampling error, cost, and inter-/intra-observer variability. There are currently available a number of noninvasive tests as an alternative to liver biopsy for fibrosis staging. These noninvasive fibrosis tests are increasingly used to rule out advanced fibrosis and help guide disease management. While these noninvasive tests perform relatively well for ruling out advanced fibrosis, they also have limitations. Understanding the strengths and limitations of liver biopsy and the noninvasive tests is necessary for deciding when to use the appropriate tests in the evaluation of patients with NAFLD.
Saranya, Raju; Aarthi, Raju; Sankaran, Krishnan
2015-05-01
Spread of drug-resistant Staphylococcus spp. into communities pose danger demanding effective non-invasive and non-destructive tools for its early detection and surveillance. Characteristic volatile organic compounds (VOCs) produced by bacteria offer new diagnostic targets and novel approaches not exploited so far in infectious disease diagnostics. Our search for such characteristic VOC for Staphylococcus spp. led to the depiction of 2-[3-acetoxy-4,4,14-trimethylandrost-8-en-17-yl] propanoic acid (ATMAP), a moderately volatile compound detected both in the culture and headspace when the organism was grown in tryptone soya broth (TSB) medium. A simple and inexpensive colorimetric method (colour change from yellow to orange) using methyl red as the pH indicator provided an absolutely specific way for identifying Staphylococcus spp., The assay performed in liquid cultures (7-h growth in TSB) as well as in the headspace of plate cultures (grown for 10 h on TSA) was optimised in a 96-well plate and 12-well plate formats, respectively, employing a set of positive and negative strains. Only Staphylococcus spp. showed the distinct colour change from yellow to orange due to the production of the above VOC while in the case of other organisms, the reagent remained yellow. The method validated using known clinical and environmental strains (56 including Staphylococcus, Proteus, Pseudomonas, Klebsiella, Bacillus, Shigella and Escherichia coli) was found to be highly efficient showing 100% specificity and sensitivity. Such simple methods of bacterial pathogen identification are expected to form the next generation tools for the control of infectious diseases through early detection and surveillance of causative agents.
Bonnet, Benjamin; Jourdan, Franck; du Cailar, Guilhem; Fesler, Pierre
2017-08-01
End-systolic left ventricular (LV) elastance ( E es ) has been previously calculated and validated invasively using LV pressure-volume (P-V) loops. Noninvasive methods have been proposed, but clinical application remains complex. The aims of the present study were to 1 ) estimate E es according to modeling of the LV P-V curve during ejection ("ejection P-V curve" method) and validate our method with existing published LV P-V loop data and 2 ) test the clinical applicability of noninvasively detecting a difference in E es between normotensive and hypertensive subjects. On the basis of the ejection P-V curve and a linear relationship between elastance and time during ejection, we used a nonlinear least-squares method to fit the pressure waveform. We then computed the slope and intercept of time-varying elastance as well as the volume intercept (V 0 ). As a validation, 22 P-V loops obtained from previous invasive studies were digitized and analyzed using the ejection P-V curve method. To test clinical applicability, ejection P-V curves were obtained from 33 hypertensive subjects and 32 normotensive subjects with carotid tonometry and real-time three-dimensional echocardiography during the same procedure. A good univariate relationship ( r 2 = 0.92, P < 0.005) and good limits of agreement were found between the invasive calculation of E es and our new proposed ejection P-V curve method. In hypertensive patients, an increase in arterial elastance ( E a ) was compensated by a parallel increase in E es without change in E a / E es In addition, the clinical reproducibility of our method was similar to that of another noninvasive method. In conclusion, E es and V 0 can be estimated noninvasively from modeling of the P-V curve during ejection. This approach was found to be reproducible and sensitive enough to detect an expected increase in LV contractility in hypertensive patients. Because of its noninvasive nature, this methodology may have clinical implications in various disease states. NEW & NOTEWORTHY The use of real-time three-dimensional echocardiography-derived left ventricular volumes in conjunction with carotid tonometry was found to be reproducible and sensitive enough to detect expected differences in left ventricular elastance in arterial hypertension. Because of its noninvasive nature, this methodology may have clinical implications in various disease states. Copyright © 2017 the American Physiological Society.
Yang, Renhuan; Li, Xu; Song, Aiguo; He, Bin; Yan, Ruqiang
2012-01-01
Electrical properties of biological tissues are highly sensitive to their physiological and pathological status. Thus it is of importance to image electrical properties of biological tissues. However, spatial resolution of conventional electrical impedance tomography (EIT) is generally poor. Recently, hybrid imaging modalities combining electric conductivity contrast and ultrasonic resolution based on acouto-electric effect has attracted considerable attention. In this study, we propose a novel three-dimensional (3D) noninvasive ultrasound Joule heat tomography (UJHT) approach based on acouto-electric effect using unipolar ultrasound pulses. As the Joule heat density distribution is highly dependent on the conductivity distribution, an accurate and high resolution mapping of the Joule heat density distribution is expected to give important information that is closely related to the conductivity contrast. The advantages of the proposed ultrasound Joule heat tomography using unipolar pulses include its simple inverse solution, better performance than UJHT using common bipolar pulses and its independence of any priori knowledge of the conductivity distribution of the imaging object. Computer simulation results show that using the proposed method, it is feasible to perform a high spatial resolution Joule heat imaging in an inhomogeneous conductive media. Application of this technique on tumor scanning is also investigated by a series of computer simulations. PMID:23123757
The Assembly of Cell-Encapsulating Microscale Hydrogels Using Acoustic Waves
Xu, Feng; Finley, Thomas Dylan; Turkaydin, Muge; Sung, Yuree; Gurkan, Umut Atakan; Yavuz, Ahmet Sinan; Guldiken, Rasim; Demirci, Utkan
2011-01-01
Microscale hydrogels find widespread applications in medicine and biology, e.g., as building blocks for tissue engineering and regenerative medicine. In these applications, these microgels are assembled to fabricate large complex 3D constructs. The success of this approach requires non-destructive and high throughput assembly of the microgels. Although various assembly methods have been developed based on modifying interfaces, and using microfluidics, so far, none of the available assembly technologies have shown the ability to assembly microgels using non-invasive fields rapidly within seconds in an efficient way. Acoustics has been widely used in biomedical area to manipulatedroplets, cells and biomolecules. In this study, we developed a simple, non-invasiveacoustic assembler for cell-encapsulating microgels with maintained cell viability (>93%). We assessed the assembler for both microbeads (with diameter of 50 µm and 100 µm) and microgels of different sizes and shapes (e.g., cubes, lock-and-key shapes, tetris, saw) in microdroplets (with volume of 10 µL, 20 µL, 40 µL, 80 µL). The microgels were assembled in second sin a non-invasive manner. These results indicate that the developed acoustic approach could become an enabling biotechnology tool for tissue engineering, regenerative medicine, pharmacology studies and high throughput screening applications. PMID:21820734
Lovino, Magalí; Cardinal, M Fernanda; Zubiri, Diana B V; Bernik, Delia L
2005-12-15
Porous silica matrices prepared by sol-gel process yield biocompatible materials adequate for encapsulation of biomolecules or drugs. The procedure is simple and fast, but when alkoxyde precursors like tetraethoxysilane (TEOS) are used the polymerisation reaction leads to the formation of alcohol as a by-product, which can produce undesirable effects on the activity of entrapped enzymes or modify a drug release kinetic. Therefore, it is critical to determine that no remnant ethanol is left prior using or storing the obtained biomaterial. In this regard, the technique used in the alcohol determination should be non-invasive and non-destructive to preserve the encapsulation device intact and ready to use. In this work we have successfully used a portable electronic nose (e-nose) for the screening of silica polymerisation process during theophylline encapsulation. TEOS reaction was "smelt" since precursor pre-hydrolysis until the end of ethanol release, sensed directly at the headspace of matrices slabs. Measurements showed that ethanol was negligible since 10th day in polymeric slabs of 10 mm width and 2 cm diameter. This first use of e-nose following a polymerisation reaction opens a wide number of putative applications in pharmaceutical and biochemical fields.
Non-invasive Differentiation of Kidney Stone Types using X-ray Dark-Field Radiography
Scherer, Kai; Braig, Eva; Willer, Konstantin; Willner, Marian; Fingerle, Alexander A.; Chabior, Michael; Herzen, Julia; Eiber, Matthias; Haller, Bernhard; Straub, Michael; Schneider, Heike; Rummeny, Ernst J.; Noël, Peter B.; Pfeiffer, Franz
2015-01-01
Treatment of renal calculi is highly dependent on the chemical composition of the stone in question, which is difficult to determine using standard imaging techniques. The objective of this study is to evaluate the potential of scatter-sensitive X-ray dark-field radiography to differentiate between the most common types of kidney stones in clinical practice. Here, we examine the absorption-to-scattering ratio of 118 extracted kidney stones with a laboratory Talbot-Lau Interferometer. Depending on their chemical composition, microscopic growth structure and morphology the various types of kidney stones show strongly varying, partially opposite contrasts in absorption and dark-field imaging. By assessing the microscopic calculi morphology with high resolution micro-computed tomography measurements, we illustrate the dependence of dark-field signal strength on the respective stone type. Finally, we utilize X-ray dark-field radiography as a non-invasive, highly sensitive (100%) and specific (97%) tool for the differentiation of calcium oxalate, uric acid and mixed types of stones, while additionally improving the detectability of radio-lucent calculi. We prove clinical feasibility of the here proposed method by accurately classifying renal stones, embedded within a fresh pig kidney, using dose-compatible measurements and a quick and simple visual inspection. PMID:25873414
Non-invasive assessment of liver fibrosis
Papastergiou, Vasilios; Tsochatzis, Emmanuel; Burroughs, Andrew K.
2012-01-01
The presence and degree of hepatic fibrosis is crucial in order to make therapeutic decisions and predict clinical outcomes. Currently, the place of liver biopsy as the standard of reference for assessing liver fibrosis has been challenged by the increasing awareness of a number of drawbacks related to its use (invasiveness, sampling error, inter-/intraobserver variability). In parallel with this, noninvasive assessment of liver fibrosis has experienced explosive growth in recent years and a wide spectrum of noninvasive methods ranging from serum assays to imaging techniques have been developed. Some are validated methods, such as the Fibrotest/ Fibrosure and transient elastography in Europe, and are gaining a growing role in routine clinical practice, especially in chronic hepatitis C. Large-scale validation is awaited in the setting of other chronic liver diseases. However, noninvasive tests used to detect significant fibrosis and cirrhosis, the two major clinical endpoints, are not yet at a level of performance suitable for routine diagnostic tests, and there is still no perfect surrogate or method able to completely replace an optimal liver biopsy. This article aims to review current noninvasive tests for the assessment of liver fibrosis and the perspectives for their rational use in clinical practice. PMID:24714123
Pyregov, A V; Ovechkin, A Iu; Petrov, S V
2012-01-01
Results of prospective randomized comparative research of 2 total hemoglobin estimation methods are presented. There were laboratory tests and continuous noninvasive technique with multiwave spectrophotometry on the Masimo Rainbow SET. Research was carried out in two stages. At the 1st stage (gynecology)--67 patients were included and in second stage (obstetrics)--44 patients during and after Cesarean section. The standard deviation of noninvasive total hemoglobin estimation from absolute values (invasive) was 7.2 and 4.1%, an standard deviation in a sample--5.2 and 2.7 % in gynecologic operations and surgical delivery respectively, that confirms lack of reliable indicators differences. The method of continuous noninvasive total hemoglobin estimation with multiwave spectrophotometry on the Masimo Rainbow SET technology can be recommended for use in obstetrics and gynecology.
Cook, Darren A N; Pilotte, Nils; Minetti, Corrado; Williams, Steven A; Reimer, Lisa J
2017-11-06
Background: Molecular xenomonitoring (MX), the testing of insect vectors for the presence of human pathogens, has the potential to provide a non-invasive and cost-effective method for monitoring the prevalence of disease within a community. Current MX methods require the capture and processing of large numbers of mosquitoes, particularly in areas of low endemicity, increasing the time, cost and labour required. Screening the excreta/feces (E/F) released from mosquitoes, rather than whole carcasses, improves the throughput by removing the need to discriminate vector species since non-vectors release ingested pathogens in E/F. It also enables larger numbers of mosquitoes to be processed per pool. However, this new screening approach requires a method of efficiently collecting E/F. Methods: We developed a cone with a superhydrophobic surface to allow for the efficient collection of E/F. Using mosquitoes exposed to either Plasmodium falciparum , Brugia malayi or Trypanosoma brucei brucei, we tested the performance of the superhydrophobic cone alongside two other collection methods. Results: All collection methods enabled the detection of DNA from the three parasites. Using the superhydrophobic cone to deposit E/F into a small tube provided the highest number of positive samples (16 out of 18) and facilitated detection of parasite DNA in E/F from individual mosquitoes. Further tests showed that following a simple washing step, the cone can be reused multiple times, further improving its cost-effectiveness. Conclusions: Incorporating the superhydrophobic cone into mosquito traps or holding containers could provide a simple and efficient method for collecting E/F. Where this is not possible, swabbing the container or using the washing method facilitates the detection of the three parasites used in this study.
Prone positioning in the patient who has acute respiratory distress syndrome: the art and science.
Vollman, Kathleen M
2004-09-01
Acute respiratory distress syndrome (ARDS) remains a significant contributor to the morbidity and mortality of patients in the ICU. A variety of treatments are used to support the lung of the patient who has ARDS and improve gas exchange during the acute injury phase. It seems, however, that the simple, safe, and noninvasive act of prone positioning of the critically ill patient who has ARDS may improve gas exchange while preventing potential complications of high positive end-expiratory pressure, volutrauma, and oxygen toxicity. This article provides the critical care nurse with the physiologic rationale for use of the prone position, indications and contraindications for use, safe strategies for prone positioning, and care techniques and monitoring methods of the patient who is in the prone position.
Ross, Michael P.
1996-01-01
A coaxial hyperthermia applicator for applying non-invasively electromagnetic energy to a body against which it is placed. The coaxial applicator antenna has formed integrally within it a non-invasive radiometric antenna for receiving thermoelectromagnetic emissions. The coaxial-configured applicator produces a bell-shaped radiation pattern symmetric about the axis of symmetry of the coaxial applicator. Integrating the radiometric antenna within the coaxial applicator produces a single device that performs dual functions. The first function is to transmit non-invasively energy for heating a subcutaneous tumor. The second function is to receive non-invasively thermal electromagnetic radiation from the tumor by which temperature is sensed and fed back to control the output of the coaxial applicator.
Ross, M.P.
1996-08-27
A coaxial hyperthermia applicator is disclosed for applying non-invasively electromagnetic energy to a body against which it is placed. The coaxial applicator antenna has formed integrally within it a non-invasive radiometric antenna for receiving thermoelectromagnetic emissions. The coaxial-configured applicator produces a bell-shaped radiation pattern symmetric about the axis of symmetry of the coaxial applicator. Integrating the radiometric antenna within the coaxial applicator produces a single device that performs dual functions. The first function is to transmit non-invasively energy for heating a subcutaneous tumor. The second function is to receive non-invasively thermal electromagnetic radiation from the tumor by which temperature is sensed and fed back to control the output of the coaxial applicator. 11 figs.
Method for non-invasive detection of ocular melanoma
Lambrecht, Richard M.; Packer, Samuel
1984-01-01
There is described an apparatus and method for diagnosing ocular cancer that is both non-invasive and accurate which comprises two radiation detectors positioned before each of the patient's eyes which will measure the radiation level produced in each eye after the administration of a tumor-localizing radiopharmaceutical such as gallium-67.
Noninvasive and cost-effective trapping method for monitoring sensitive mammal populations
Stephanie E. Trapp; Elizabeth A. Flaherty
2017-01-01
Noninvasive sampling methods provide a means to monitor endangered, threatened, or sensitive species or populations while increasing the efficacy of personnel effort and time. We developed a monitoring protocol that utilizes single-capture hair snares and analysis of morphological features of hair for evaluating populations. During 2015, we used the West Virginia...
Method for non-invasive detection of ocular melanoma
Lambrecht, R.M.; Packer, S.
1984-10-30
An apparatus and method is disclosed for diagnosing ocular cancer that is both non-invasive and accurate. The apparatus comprises two radiation detectors positioned before each of the patient's eyes which will measure the radiation level produced in each eye after the administration of a tumor-localizing radiopharmaceutical such as gallium-67. 2 figs.
NASA Astrophysics Data System (ADS)
Chlebda, Damian K.; Majda, Alicja; Łojewski, Tomasz; Łojewska, Joanna
2016-11-01
Differentiation of the written text can be performed with a non-invasive and non-contact tool that connects conventional imaging methods with spectroscopy. Hyperspectral imaging (HSI) is a relatively new and rapid analytical technique that can be applied in forensic science disciplines. It allows an image of the sample to be acquired, with full spectral information within every pixel. For this paper, HSI and three statistical methods (hierarchical cluster analysis, principal component analysis, and spectral angle mapper) were used to distinguish between traces of modern black gel pen inks. Non-invasiveness and high efficiency are among the unquestionable advantages of ink differentiation using HSI. It is also less time-consuming than traditional methods such as chromatography. In this study, a set of 45 modern gel pen ink marks deposited on a paper sheet were registered. The spectral characteristics embodied in every pixel were extracted from an image and analysed using statistical methods, externally and directly on the hypercube. As a result, different black gel inks deposited on paper can be distinguished and classified into several groups, in a non-invasive manner.
Snyder-Mackler, Noah; Majoros, William H.; Yuan, Michael L.; Shaver, Amanda O.; Gordon, Jacob B.; Kopp, Gisela H.; Schlebusch, Stephen A.; Wall, Jeffrey D.; Alberts, Susan C.; Mukherjee, Sayan; Zhou, Xiang; Tung, Jenny
2016-01-01
Research on the genetics of natural populations was revolutionized in the 1990s by methods for genotyping noninvasively collected samples. However, these methods have remained largely unchanged for the past 20 years and lag far behind the genomics era. To close this gap, here we report an optimized laboratory protocol for genome-wide capture of endogenous DNA from noninvasively collected samples, coupled with a novel computational approach to reconstruct pedigree links from the resulting low-coverage data. We validated both methods using fecal samples from 62 wild baboons, including 48 from an independently constructed extended pedigree. We enriched fecal-derived DNA samples up to 40-fold for endogenous baboon DNA and reconstructed near-perfect pedigree relationships even with extremely low-coverage sequencing. We anticipate that these methods will be broadly applicable to the many research systems for which only noninvasive samples are available. The lab protocol and software (“WHODAD”) are freely available at www.tung-lab.org/protocols-and-software.html and www.xzlab.org/software.html, respectively. PMID:27098910
[Spiral CT angiography in practice].
Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko
2005-01-01
Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.
A new method for noninvasive venous blood oxygen detection.
Zhang, Xu; Zhang, Meimei; Zheng, Shengkun; Wang, Liqi; Ye, Jilun
2016-07-19
Blood oxygen saturation of vein (SvO2) is an important clinical parameter for patient monitoring. However, the existing clinical methods are invasive, expensive, which are also painful for patients. Based on light-absorption, this study describes a new noninvasive SvO2 measurement method by using external stimulation signal to generate cyclical fluctuation signal in the vein, which overcomes the low signal-to-noise ratio problem in the measurement process. In this way, the value of SvO2 can be obtained continuously in real time. The experimental results demonstrate that the method can successfully measure venous oxygen saturation by artificial addition of stimulation. Under hypoxic conditions, the system can reflect the overall decline of venous oxygen saturation better. When the results measured by the new method are compared with those measured by the invasive method, the root mean square error of the difference is 5.31 and the correlation coefficient of the difference is 0.72. The new method can be used to measure SvO2 and evaluate body oxygen consumption, and its accuracy needs improvement. Real-time and continuous monitoring can be achieved by replacing invasive method with noninvasive method, which provides more comprehensive clinical information in a timely manner and better meet the needs of clinical treatment. However, the accuracy of the new noninvasive SvO2 measurement based on light-absorption has to be further improved.
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, Tushar Kanti
2014-01-01
Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends. PMID:27006932
Non-invasive prenatal detection of achondroplasia using circulating fetal DNA in maternal plasma.
Lim, Ji Hyae; Kim, Mee Jin; Kim, Shin Young; Kim, Hye Ok; Song, Mee Jin; Kim, Min Hyoung; Park, So Yeon; Yang, Jae Hyug; Ryu, Hyun Mee
2011-02-01
To perform a reliable non-invasive detection of the fetal achondroplasia using maternal plasma. We developed a quantitative fluorescent-polymerase chain reaction (QF-PCR) method suitable for detection of the FGFR3 mutation (G1138A) causing achondroplasia. This method was applied in a non-invasive detection of the fetal achondroplasia using circulating fetal-DNA (cf-DNA) in maternal plasma. Maternal plasmas were obtained at 27 weeks of gestational age from women carrying an achondroplasia fetus or a normal fetus. Two percent or less achondroplasia DNA was reliably detected by QF-PCR. In a woman carrying a normal fetus, analysis of cf-DNA showed only one peak of the wild-type G allele. In a woman expected an achondroplasia fetus, analysis of cf-DNA showed the two peaks of wild-type G allele and mutant-type A allele and accurately detected the fetal achondroplasia. The non-invasive method using maternal plasma and QF-PCR may be useful for diagnosis of the fetal achondroplasia.
Lee, Sangmin; Yoon, Hwa In; Na, Jin Hee; Jeon, Sangmin; Lim, Seungho; Koo, Heebeom; Han, Sang-Soo; Kang, Sun-Woong; Park, Soon-Jung; Moon, Sung-Hwan; Park, Jae Hyung; Cho, Yong Woo; Kim, Byung-Soo; Kim, Sang Kyoon; Lee, Taekwan; Kim, Dongkyu; Lee, Seulki; Pomper, Martin G; Kwon, Ick Chan; Kim, Kwangmeyung
2017-09-01
It is urgently necessary to develop reliable non-invasive stem cell imaging technology for tracking the in vivo fate of transplanted stem cells in living subjects. Herein, we developed a simple and well controlled stem cell imaging method through a combination of metabolic glycoengineering and bioorthogonal copper-free click chemistry. Firstly, the exogenous chemical receptors containing azide (-N 3 ) groups were generated on the surfaces of stem cells through metabolic glycoengineering using metabolic precursor, tetra-acetylated N-azidoacetyl-d-mannosamine(Ac 4 ManNAz). Next, bicyclo[6.1.0]nonyne-modified glycol chitosan nanoparticles (BCN-CNPs) were prepared as imageable nanoparticles to deliver different imaging agents. Cy5.5, iron oxide nanoparticles and gold nanoparticles were conjugated or encapsulated to BCN-CNPs for optical, MR and CT imaging, respectively. These imageable nanoparticles bound chemical receptors on the Ac 4 ManNAz-treated stem cell surface specifically via bioorthogonal copper-free click chemistry. Then they were rapidly taken up by the cell membrane turn-over mechanism resulting in higher endocytic capacity compared non-specific uptake of nanoparticles. During in vivo animal test, BCN-CNP-Cy5.5-labeled stem cells could be continuously tracked by non-invasive optical imaging over 15 days. Furthermore, BCN-CNP-IRON- and BCN-CNP-GOLD-labeled stem cells could be efficiently visualized using in vivo MR and CT imaging demonstrating utility of our stem cell labeling method using chemical receptors. These results conclude that our method based on metabolic glycoengineering and bioorthogonal copper-free click chemistry can stably label stem cells with diverse imageable nanoparticles representing great potential as new stem cell imaging technology. Copyright © 2017 Elsevier Ltd. All rights reserved.
Machado, Ana; Maneiras, Rui; Bordalo, Adriano A; Mesquita, Raquel B R
2018-08-15
The use of saliva for diagnose and surveillance of systemic illnesses, and general health has been arousing great interest worldwide, emerging as a highly desirable goal in healthcare. The collection is non-invasive, stress-free, inexpensive, and simple representing a major asset. Glucose, calcium, and magnesium concentration are three major parameters evaluated in clinical context due to their essential role in a wide range of biochemical reactions, and consequently many health disorders. In this work, a spectrophotometric sequential injection method is described for the fast screening of glucose, calcium, and magnesium in saliva samples. The glucose determination reaction involves the oxidation of the aldehyde functional group present in glucose with simultaneous reduction of 3,5-dinitrosalicylic acid (DNS) to 3-amino, 5-nitrosalicylic acid under alkaline conditions, followed by the development of colour. The determination of both metals is based on their reaction with cresolphtalein complexone (CPC), and the interference of calcium in the magnesium determination minimized by ethylene glycol-bis[β-aminoethyl ether]-N,N,N',N'-tetraacetic acid (EGTA). The developed multi-parametric method enabled dynamic ranges of 50 - 300 mg/dL for glucose, 0.1 - 2 mg/dL for calcium, and 0.1 - 0.5 mg/dL for magnesium. Determination rates of 28, 60, 52 h -1 were achieved for glucose, calcium, and magnesium, respectively. Less than 300 µL of saliva is required for the multi-parametric determination due to saliva viscosity and inherent necessity of dilution prior to analysis. RSDs lower than 5% were obtained, and the results agreed with those obtained by reference methods, while recovery tests confirmed its accuracy. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bai, Ou; Lin, Peter; Vorbach, Sherry; Floeter, Mary Kay; Hattori, Noriaki; Hallett, Mark
2008-03-01
To explore the reliability of a high performance brain-computer interface (BCI) using non-invasive EEG signals associated with human natural motor behavior does not require extensive training. We propose a new BCI method, where users perform either sustaining or stopping a motor task with time locking to a predefined time window. Nine healthy volunteers, one stroke survivor with right-sided hemiparesis and one patient with amyotrophic lateral sclerosis (ALS) participated in this study. Subjects did not receive BCI training before participating in this study. We investigated tasks of both physical movement and motor imagery. The surface Laplacian derivation was used for enhancing EEG spatial resolution. A model-free threshold setting method was used for the classification of motor intentions. The performance of the proposed BCI was validated by an online sequential binary-cursor-control game for two-dimensional cursor movement. Event-related desynchronization and synchronization were observed when subjects sustained or stopped either motor execution or motor imagery. Feature analysis showed that EEG beta band activity over sensorimotor area provided the largest discrimination. With simple model-free classification of beta band EEG activity from a single electrode (with surface Laplacian derivation), the online classifications of the EEG activity with motor execution/motor imagery were: >90%/~80% for six healthy volunteers, >80%/~80% for the stroke patient and ~90%/~80% for the ALS patient. The EEG activities of the other three healthy volunteers were not classifiable. The sensorimotor beta rhythm of EEG associated with human natural motor behavior can be used for a reliable and high performance BCI for both healthy subjects and patients with neurological disorders. Significance: The proposed new non-invasive BCI method highlights a practical BCI for clinical applications, where the user does not require extensive training.
Large area, label-free imaging of extracellular matrix using telecentricity
NASA Astrophysics Data System (ADS)
Visbal Onufrak, Michelle A.; Konger, Raymond L.; Kim, Young L.
2017-02-01
Subtle alterations in stromal tissue structures and organizations within the extracellular matrix (ECM) have been observed in several types of tissue abnormalities, including early skin cancer and wounds. Current microscopic imaging methods often lack the ability to accurately determine the extent of malignancy over a large area, due to their limited field of view. In this research we focus on the development of simple mesoscopic (i.e. between microscopic and macroscopic) biomedical imaging device for non-invasive assessment of ECM alterations over a large, heterogeneous area. In our technology development, a telecentric lens, commonly used in machine vision systems but rarely used in biomedical imaging, serves as a key platform to visualize alterations in tissue microenvironments in a label-free manner over a clinically relevant area. In general, telecentric imaging represents a simple, alternative method for reducing unwanted scattering or diffuse light caused by the highly anisotropic scattering properties of biological tissue. In particular, under telecentric imaging the light intensity backscattered from biological tissue is mainly sensitive to the scattering anisotropy factor, possibly associated with the ECM. We demonstrate the inherent advantages of combining telecentric lens systems with hyperspectral imaging for providing optical information of tissue scattering in biological tissue of murine models, as well as light absorption of hemoglobin in blood vessel tissue phantoms. Thus, we envision that telecentric imaging could potentially serve for simple site-specific, tissue-based assessment of stromal alterations over a clinically relevant field of view in a label-free manner, for studying diseases associated with disruption of homeostasis in ECM.
American Society for Laser Medicine and Surgery
... Sep 26, 2017 Promising Results for Noninvasive Facial Fat Reduction JOURNAL | POSTED: Oct 16, 2017 November Issue ... of Acne Scaring Promising Results for Noninvasive Facial Fat Reduction New Method Tested for Diagnosing and Assessing ...
Clifton, Lei; Clifton, David A; Hahn, Clive E W; Farmeryy, Andrew D
2013-01-01
Conventional methods for estimating cardiopulmonary variables usually require complex gas analyzers and the active co-operation of the patient. Therefore, they are not compatible with the crowded environment of the intensive care unit (ICU) or operating theatre, where patient co-operation is typically impossible. However, it is these patients that would benefit the most from accurate estimation of cardiopulmonary variables, because of their critical condition. This paper describes the results of a collaborative development between an anesthesiologists and biomedical engineers to create a compact and non-invasive system for the measurement of cardiopulmonary variables such as lung volume, airway dead space volume, and pulmonary blood flow. In contrast with conventional methods, the compact apparatus and non-invasive nature of the proposed method allow it to be used in the ICU, as well as in general clinical settings. We propose the use of a non-invasive method, in which tracer gases are injected into the patient's inspired breath, and the concentration of the tracer gases is subsequently measured. A novel breath-by-breath tidal ventilation model is then used to estimate the value of a patient's cardiopulmonary variables. Experimental results from an artificial lung demonstrate minimal error in the estimation of known parameters using the proposed method. Results from analysis of a cohort of 20 healthy volunteers (within the Oxford University Hospitals NHS Trust) show that the values of estimated cardiopulmonary variables from these subjects lies within the expected ranges. Advantages of this method are that it is non-invasive, compact, portable, and can perform analysis in real time with less than 1 min of acquired respiratory data.
Non-invasive assessment of liver fibrosis in patients with alcoholic liver disease
Lombardi, Rosa; Buzzetti, Elena; Roccarina, Davide; Tsochatzis, Emmanuel A
2015-01-01
Alcoholic liver disease (ALD) consists of a broad spectrum of disorders, ranging from simple steatosis to alcoholic steatohepatitis and cirrhosis. Fatty liver develops in more than 90% of heavy drinkers, however only 30%-35% of them develop more advanced forms of ALD. Therefore, even if the current “gold standard” for the assessment of the stage of alcohol-related liver injury is histology, liver biopsy is not reasonable in all patients who present with ALD. Currently, although several non-invasive fibrosis markers have been suggested as alternatives to liver biopsy in patients with ALD, none has been sufficiently validated. As described in other liver disease, the diagnostic accuracy of such tests in ALD is acceptable for the diagnosis of significant fibrosis or cirrhosis but not for lesser fibrosis stages. Existing data suggest that the use of non-invasive tests could be tailored to first tier screening of patients at risk, in order to diagnose early patients with progressive liver disease and offer targeted interventions for the prevention of decompensation. We review these tests and critically appraise the existing evidence. PMID:26494961
Non-invasive assessment of liver fibrosis in patients with alcoholic liver disease.
Lombardi, Rosa; Buzzetti, Elena; Roccarina, Davide; Tsochatzis, Emmanuel A
2015-10-21
Alcoholic liver disease (ALD) consists of a broad spectrum of disorders, ranging from simple steatosis to alcoholic steatohepatitis and cirrhosis. Fatty liver develops in more than 90% of heavy drinkers, however only 30%-35% of them develop more advanced forms of ALD. Therefore, even if the current "gold standard" for the assessment of the stage of alcohol-related liver injury is histology, liver biopsy is not reasonable in all patients who present with ALD. Currently, although several non-invasive fibrosis markers have been suggested as alternatives to liver biopsy in patients with ALD, none has been sufficiently validated. As described in other liver disease, the diagnostic accuracy of such tests in ALD is acceptable for the diagnosis of significant fibrosis or cirrhosis but not for lesser fibrosis stages. Existing data suggest that the use of non-invasive tests could be tailored to first tier screening of patients at risk, in order to diagnose early patients with progressive liver disease and offer targeted interventions for the prevention of decompensation. We review these tests and critically appraise the existing evidence.
Monitoring Species of Concern Using Noninvasive Genetic Sampling and Capture-Recapture Methods
2016-11-01
ABBREVIATIONS AICc Akaike’s Information Criterion with small sample size correction AZGFD Arizona Game and Fish Department BMGR Barry M. Goldwater...MNKA Minimum Number Known Alive N Abundance Ne Effective Population Size NGS Noninvasive Genetic Sampling NGS-CR Noninvasive Genetic...parameter estimates from capture-recapture models require sufficient sample sizes , capture probabilities and low capture biases. For NGS-CR, sample
Development of Noninvasive Blood Glucose Sensor Using the Infrared Spectroscopy
NASA Astrophysics Data System (ADS)
Fujita, Keiichi; Tamura, Kazuto; Kaneko, Wataru; Ishizawa, Hiroaki; Toba, Eiji
Recently, diabetics have been steadily increasing, because change of diet, lack of exercise, increase an alcoholic intake, and increase a stress. It is a very serious problem for us. About 23.6 millions of people in Japan approach the danger of diabetes. Therefore, it is necessary to get insulin injection. And they have to measure blood glucose again and again a day. So, they are burden too heavy. This paper describes a new noninvasive measurement of blood glucose based on optical sensing. This uses Fourier transform infrared spectroscopy of attenuated total reflection. Non-invasive measurement was carried out by using 3 methods. And standard error of prediction is about ±20mg/dl by 3 method. This paper also describes practical application of this method.
Non-invasive diagnostic methods in dentistry
NASA Astrophysics Data System (ADS)
Todea, Carmen
2016-03-01
The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.
Noninvasive and Real-Time Plasmon Waveguide Resonance Thermometry
Zhang, Pengfei; Liu, Le; He, Yonghong; Zhou, Yanfei; Ji, Yanhong; Ma, Hui
2015-01-01
In this paper, the noninvasive and real-time plasmon waveguide resonance (PWR) thermometry is reported theoretically and demonstrated experimentally. Owing to the enhanced evanescent field and thermal shield effect of its dielectric layer, a PWR thermometer permits accurate temperature sensing and has a wide dynamic range. A temperature measurement sensitivity of 9.4 × 10−3 °C is achieved and the thermo optic coefficient nonlinearity is measured in the experiment. The measurement of water cooling processes distributed in one dimension reveals that a PWR thermometer allows real-time temperature sensing and has potential to be applied for thermal gradient analysis. Apart from this, the PWR thermometer has the advantages of low cost and simple structure, since our transduction scheme can be constructed with conventional optical components and commercial coating techniques. PMID:25871718
Non-invasive indices for the estimation of the anaerobic threshold of oarsmen.
Erdogan, A; Cetin, C; Karatosun, H; Baydar, M L
2010-01-01
This study compared four common non-invasive indices with an invasive index for determining the anaerobic threshold (AT) in 22 adult male rowers using a Concept2 rowing ergometer. A criterion-standard progressive incremental test (invasive method) measured blood lactate concentrations to determine the 4 mmol/l threshold (La4-AT) and Dmax AT (Dm-AT). This was compared with three indices obtained by analysis of respiratory gases and one that was based on the heart rate (HR) deflection point (HRDP) all of which used the Conconi test (non-invasive methods). In the Conconi test, the HRDP was determined whilst continuously increasing the power output (PO) by 25 W/min and measuring respiratory gases and HR. The La4-AT and Dm-AT values differed slightly with respect to oxygen uptake, PO and HR however, AT values significantly correlated with each other and with the four non-invasive methods. In conclusion, the non-invasive indices were comparable with the invasive index and could, therefore, be used in the assessment of AT during rowing ergometer use. In this population of elite rowers, Conconi threshold (Con-AT), based on the measurement of HRDP tended to be the most adequate way of estimating AT for training regulation purposes.
Bai, Yuqiang; Nichols, Jason J
2017-05-01
The thickness of tear film has been investigated under both invasive and non-invasive methods. While invasive methods are largely historical, more recent noninvasive methods are generally based on optical approaches that provide accurate, precise, and rapid measures. Optical microscopy, interferometry, and optical coherence tomography (OCT) have been developed to characterize the thickness of tear film or certain aspects of the tear film (e.g., the lipid layer). This review provides an in-depth overview on contemporary optical techniques used in studying the tear film, including both advantages and limitations of these approaches. It is anticipated that further developments of high-resolution OCT and other interferometric methods will enable a more accurate and precise measurement of the thickness of the tear film and its related dynamic properties. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Peng, Dong-qing; Zhu, Li-li; Li, Zhi-fang; Li, Hui
2017-09-01
Absorption coefficient of biological tissue is an important parameter in biomedicine, but its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique and internal light irradiation of cylindrical diffusing fiber (CDF) to quantify the target optical absorption coefficient. Absorption coefficients for ink absorbers are firstly determined through photoacoustic and spectrophotometric measurements at the same excitation, which demonstrates the feasibility of this method. Also, the optical absorption coefficients of ink absorbers with several concentrations are measured. Finally, the two-dimensional scanning photoacoustic image is obtained. Optical absorption coefficient measurement and simultaneous photoacoustic imaging of absorber non-invasively are the typical characteristics of the method. This method can play a significant role for non-invasive determination of blood oxygen saturation, the absorption-based imaging and therapy.
Adamek, Martina; Opelz, Gerhard; Klein, Katrin; Morath, Christian; Tran, Thuong Hien
2016-07-01
Timely detection of graft rejection is an important issue in the follow-up care after solid organ transplantation. Until now, biopsy has been considered the "gold standard" in the diagnosis of graft rejection. However, non-invasive tests such as monitoring the levels of cell-free DNA (cfDNA) as a sensitive biomarker for graft integrity have attracted increasing interest. The rationale of this approach is that a rejected organ will lead to a significant release of donor-derived cfDNA, which can be detected in the serum of the transplant recipient. We have developed a novel quantitative real-time PCR (qPCR) approach for detecting an increase of donor-derived cfDNA in the recipient's serum. Common insertion/deletion (InDel) genetic polymorphisms, which differ between donor and recipient, are targeted in our qPCR assay. In contrast to some other strategies, no specific donor/recipient constellations such as certain gender combinations or human leukocyte antigen (HLA) discrepancies are required for the application of our test. The method was first validated with serial dilutions of serum mixtures obtained from healthy blood donors and then used to determine donor-derived cfDNA levels in patients' sera within the first 3 days after their kidney transplantation had been performed. Our method represents a universally applicable, simple and cost-effective tool which can potentially be used to detect graft dysfunction in transplant recipients.
Mountain, James E.; Santer, Peter; O’Neill, David P.; Smith, Nicholas M. J.; Ciaffoni, Luca; Couper, John H.; Ritchie, Grant A. D.; Hancock, Gus; Whiteley, Jonathan P.
2018-01-01
Inhomogeneity in the lung impairs gas exchange and can be an early marker of lung disease. We hypothesized that highly precise measurements of gas exchange contain sufficient information to quantify many aspects of the inhomogeneity noninvasively. Our aim was to explore whether one parameterization of lung inhomogeneity could both fit such data and provide reliable parameter estimates. A mathematical model of gas exchange in an inhomogeneous lung was developed, containing inhomogeneity parameters for compliance, vascular conductance, and dead space, all relative to lung volume. Inputs were respiratory flow, cardiac output, and the inspiratory and pulmonary arterial gas compositions. Outputs were expiratory and pulmonary venous gas compositions. All values were specified every 10 ms. Some parameters were set to physiologically plausible values. To estimate the remaining unknown parameters and inputs, the model was embedded within a nonlinear estimation routine to minimize the deviations between model and data for CO2, O2, and N2 flows during expiration. Three groups, each of six individuals, were studied: young (20–30 yr); old (70–80 yr); and patients with mild to moderate chronic obstructive pulmonary disease (COPD). Each participant undertook a 15-min measurement protocol six times. For all parameters reflecting inhomogeneity, highly significant differences were found between the three participant groups (P < 0.001, ANOVA). Intraclass correlation coefficients were 0.96, 0.99, and 0.94 for the parameters reflecting inhomogeneity in deadspace, compliance, and vascular conductance, respectively. We conclude that, for the particular participants selected, highly repeatable estimates for parameters reflecting inhomogeneity could be obtained from noninvasive measurements of respiratory gas exchange. NEW & NOTEWORTHY This study describes a new method, based on highly precise measures of gas exchange, that quantifies three distributions that are intrinsic to the lung. These distributions represent three fundamentally different types of inhomogeneity that together give rise to ventilation-perfusion mismatch and result in impaired gas exchange. The measurement technique has potentially broad clinical applicability because it is simple for both patient and operator, it does not involve ionizing radiation, and it is completely noninvasive. PMID:29074714
Gamella, M; Campuzano, S; Manso, J; González de Rivera, G; López-Colino, F; Reviejo, A J; Pingarrón, J M
2014-01-02
A non-invasive, passive and simple to use skin surface based sensing device for determining the blood's ethanol content (BAC) by monitoring transdermal alcohol concentration (TAC) is designed and developed. The proposed prototype is based on bienzyme amperometric composite biosensors that are sensitive to the variation of ethanol concentration. The prototype correlates, through previous calibration set-up, the amperometric signal generated from ethanol in sweat with its content in blood in a short period of time. The characteristics of this sensor device permit determination of the ethanol concentration in isolated and in continuous form, giving information of the BAC of a subject either in a given moment or its evolution during long periods of time (8h). Moreover, as the measurements are performed in a biological fluid, the evaluated individual is not able to alter the result of the analysis. The maximum limit of ethanol in blood allowed by legislation is included within the linear range of the device (0.0005-0.6 g L(-1)). Moreover, the device shows higher sensitivity than the breathalyzers marketed at the moment, allowing the monitoring of the ethanol content in blood to be obtained just 5 min after ingestion of the alcoholic drink. The comparison of the obtained results using the proposed device in the analysis of 40 volunteers with those provided by the gas chromatographic reference method for determination of BAC pointed out that there were no significant differences between both methods. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Schiepers, Christiaan; Hoh, Carl K.; Dahlbom, Magnus; Wu, Hsiao-Ming; Phelps, Michael E.
1999-05-01
PET imaging can quantify metabolic processes in-vivo; this requires the measurement of an input function which is invasive and labor intensive. A non-invasive, semi-automated, image based method of input function generation would be efficient, patient friendly, and allow quantitative PET to be applied routinely. A fully automated procedure would be ideal for studies across institutions. Factor analysis (FA) was applied as processing tool for definition of temporally changing structures in the field of view. FA has been proposed earlier, but the perceived mathematical difficulty has prevented widespread use. FA was utilized to delineate structures and extract blood and tissue time-activity-curves (TACs). These TACs were used as input and output functions for tracer kinetic modeling, the results of which were compared with those from an input function obtained with serial blood sampling. Dynamic image data of myocardial perfusion studies with N-13 ammonia, O-15 water, or Rb-82, cancer studies with F-18 FDG, and skeletal studies with F-18 fluoride were evaluated. Correlation coefficients of kinetic parameters obtained with factor and plasma input functions were high. Linear regression usually furnished a slope near unity. Processing time was 7 min/patient on an UltraSPARC. Conclusion: FA can non-invasively generate input functions from image data eliminating the need for blood sampling. Output (tissue) functions can be simultaneously generated. The method is simple, requires no sophisticated operator interaction and has little inter-operator variability. FA is well suited for studies across institutions and standardized evaluations.
Li, Ling; Zhang, Guo-Fang; Lee, Kwangwon; Lopez, Rocio; Previs, Stephen F; Willard, Belinda; McCullough, Arthur; Kasumov, Takhar
2016-07-01
Oxidative stress plays a key role in the pathogenesis of non-alcoholic fatty liver disease (NAFLD). Glutathione is the major anti-oxidant involved in cellular oxidative defense, however there are currently no simple non-invasive methods for assessing hepatic glutathione metabolism in patients with NAFLD. As a primary source of plasma glutathione, liver plays an important role in interorgan glutathione homeostasis. In this study, we have tested the hypothesis that measurements of plasma glutathione turnover could be used to assess the hepatic glutathione metabolism in LDLR(-/)(-) mice, a mouse model of diet-induced NAFLD. Mice were fed a standard low fat diet (LFD) or a high fat diet containing cholesterol (a Western type diet (WD)). The kinetics of hepatic and plasma glutathione were quantified using the (2)H2O metabolic labeling approach. Our results show that a WD leads to reduced fractional synthesis rates (FSR) of hepatic (25%/h in LFD vs. 18%/h in WD, P<0.05) and plasma glutathione (43%/h in LFD vs. 21%/h in WD, P<0.05), without any significant effect on their absolute production rates (PRs). WD-induced concordant changes in both hepatic and plasma glutathione turnover suggest that the plasma glutathione turnover measurements could be used to assess hepatic glutathione metabolism. The safety, simplicity, and low cost of the (2)H2O-based glutathione turnover approach suggest that this method has the potential for non-invasive probing of hepatic glutathione metabolism in patients with NAFLD and other diseases. Copyright © 2016 Elsevier Inc. All rights reserved.
Li, Ling; Zhang, Guo-Fang; Lee, Kwangwon; Lopez, Rocio; Previs, Stephen F.; Willard, Belinda; McCullough, Arthur; Kasumov, Takhar
2017-01-01
Oxidative stress plays a key role in the pathogenesis of non-alcoholic fatty liver disease (NAFLD). Glutathione is the major anti-oxidant involved in cellular oxidative defense, however there are currently no simple non-invasive methods for assessing hepatic glutathione metabolism in patients with NAFLD. As a primary source of plasma glutathione, liver plays an important role in interorgan glutathione homeostasis. In this study, we have tested the hypothesis that measurements of plasma glutathione turnover could be used to assess the hepatic glutathione metabolism in LDLR−/− mice, a mouse model of diet-induced NAFLD. Mice were fed a standard low fat diet (LFD) or a high fat diet containing cholesterol (a Western type diet (WD)). The kinetics of hepatic and plasma glutathione were quantified using the 2H2O metabolic labeling approach. Our results show that a WD leads to reduced fractional synthesis rates (FSR) of hepatic (25%/h in LFD vs. 18%/h in WD, P < 0.05) and plasma glutathione (43%/h in LFD vs. 21%/h in WD, P <0.05), without any significant effect on their absolute production rates (PRs). WD-induced concordant changes in both hepatic and plasma glutathione turnover suggest that the plasma glutathione turnover measurements could be used to assess hepatic glutathione metabolism. The safety, simplicity, and low cost of the 2H2O-based glutathione turnover approach suggest that this method has the potential for non-invasive probing of hepatic glutathione metabolism in patients with NAFLD and other diseases. PMID:27036364
Kim, Jae-Hun; Lee, Jong-Min; Jo, Hang Joon; Kim, Sook Hui; Lee, Jung Hee; Kim, Sung Tae; Seo, Sang Won; Cox, Robert W; Na, Duk L; Kim, Sun I; Saad, Ziad S
2010-02-01
Noninvasive parcellation of the human cerebral cortex is an important goal for understanding and examining brain functions. Recently, the patterns of anatomical connections using diffusion tensor imaging (DTI) have been used to parcellate brain regions. Here, we present a noninvasive parcellation approach that uses "functional fingerprints" obtained by correlation measures on resting state functional magnetic resonance imaging (fMRI) data to parcellate brain regions. In other terms, brain regions are parcellated based on the similarity of their connection--as reflected by correlation during resting state--to the whole brain. The proposed method was used to parcellate the medial frontal cortex (MFC) into supplementary motor areas (SMA) and pre-SMA subregions. In agreement with anatomical landmark-based parcellation, we find that functional fingerprint clustering of the MFC results in anterior and posterior clusters. The probabilistic maps from 12 subjects showed that the anterior cluster is mainly located rostral to the vertical commissure anterior (VCA) line, whereas the posterior cluster is mainly located caudal to VCA line, suggesting the homologues of pre-SMA and SMA. The functional connections from the putative pre-SMA cluster were connected to brain regions which are responsible for complex/cognitive motor control, whereas those from the putative SMA cluster were connected to brain regions which are related to the simple motor control. These findings demonstrate the feasibility of the functional connectivity-based parcellation of the human cerebral cortex using resting state fMRI. Copyright (c) 2009 Elsevier Inc. All rights reserved.
Dalla Nora, Magali; Hörner, Rosmari; De Carli, Diego Michelon; Rocha, Marta Pires da; Araujo, Amanda Faria de; Fagundes, Renato Borges
2016-01-01
The diagnosis of H. pylori infection can be performed by non-invasive and invasive methods.The identification through a fecal antigen test is a non-invasive, simple, and relatively inexpensive test. To determine the diagnostic performance of fecal antigen test in the identification of H. pylori infection. H. pylori antigens were identified in the stools of dyspeptic patients undergoing upper gastrointestinal endoscopy. For the identification of H. pylori antigen, we use ImmunoCard STAT! HpSA with immunochromatography technique. Histopathology plus urease test were the gold standard. We studied 163 patients, 51% male, mean age of 56.7± 8.5years. H. pylori infection was present in 49%. Fecal test presented: sensitivity 67.5% (CI95% 60.6-72.9); specificity 85.5% (CI95% 78.9-90.7); positive predictive value 81.8% (CI95% 73.4-88.4) and negative predictive value 73,2% (CI95% 67.5-77.6); Positive likelihood ratio was 4.7 (CI95% 2.9-7.9) and Negative Likelihood Ratio 0.4 (CI95% 0.3-0.5). The prevalence odds ratio for a positive test was 12.3 (CI95% 5.7-26.3).The index kappa between FAT and histology/urease test was 0.53 (CI95% 0.39-0.64). Immunochromatographic FAT is less expensive than the other methods and readily accepted by the patients but its diagnostic performance does not recommend its use in the primary diagnosis, when the patient may have an active infection.
Animal origin of 13th-century uterine vellum revealed using noninvasive peptide fingerprinting
Fiddyment, Sarah; Holsinger, Bruce; Ruzzier, Chiara; Devine, Alexander; Binois, Annelise; Albarella, Umberto; Fischer, Roman; Nichols, Emma; Curtis, Antoinette; Cheese, Edward; Teasdale, Matthew D.; Checkley-Scott, Caroline; Milner, Stephen J.; Rudy, Kathryn M.; Johnson, Eric J.; Vnouček, Jiří; Garrison, Mary; McGrory, Simon; Bradley, Daniel G.; Collins, Matthew J.
2015-01-01
Tissue-thin parchment made it possible to produce the first pocket Bibles: Thousands were made in the 13th century. The source of this parchment, often called “uterine vellum,” has been a long-standing controversy in codicology. Use of the Latin term abortivum in many sources has led some scholars to suggest that the skin of fetal calves or sheep was used. Others have argued that it would not be possible to sustain herds if so many pocket Bibles were produced from fetal skins, arguing instead for unexpected alternatives, such as rabbit. Here, we report a simple and objective technique using standard conservation treatments to identify the animal origin of parchment. The noninvasive method is a variant on zooarchaeology by mass spectrometry (ZooMS) peptide mass fingerprinting but extracts protein from the parchment surface by using an electrostatic charge generated by gentle rubbing of a PVC eraser on the membrane surface. Using this method, we analyzed 72 pocket Bibles originating in France, England, and Italy and 293 additional parchment samples that bracket this period. We found no evidence for the use of unexpected animals; however, we did identify the use of more than one mammal species in a single manuscript, consistent with the local availability of hides. These results suggest that ultrafine vellum does not necessarily derive from the use of abortive or newborn animals with ultrathin hides, but could equally well reflect a production process that allowed the skins of maturing animals of several species to be rendered into vellum of equal quality and fineness. PMID:26598667
Invasive and noninvasive hemodynamic monitoring of patients with cerebrovascular accidents.
Velmahos, G C; Wo, C C; Demetriades, D; Bishop, M H; Shoemaker, W C
1998-01-01
Seventeen patients with hemodynamic instability from acute cerebrovascular accidents were evaluated shortly after arrival at the emergency department of a university-run county hospital with both invasive Swan-Ganz pulmonary artery catheter placement and a new, noninvasive, thoracic electrical bioimpedance device. Values were recorded and temporal patterns of survivors and nonsurvivors were described. Cardiac indices obtained simultaneously by the 2 techniques were compared. Of the 17 patients, 11 (65%) died. Survivors had higher values than nonsurvivors for mean arterial pressure, cardiac index, and oxygen saturation, delivery, and consumption at comparable times. Cardiac index values, as measured by invasive and noninvasive methods, were correlated. We concluded that hemodynamic monitoring in an acute care setting may recognize temporal circulatory patterns associated with outcome. Noninvasive electrical bioimpedance technology offers a new method for early hemodynamic evaluation. Further research in this area is warranted. PMID:9682626
Tissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring
NASA Astrophysics Data System (ADS)
Woo, Sung Hun; Choi, Yun Young; Kim, Dae Jung; Bien, Franklin; Kim, Jae Joon
2014-10-01
Accurate continuous direct measurement of the blood pressure is currently available thru direct invasive methods via intravascular needles, and is mostly limited to use during surgical procedures or in the intensive care unit (ICU). Non-invasive methods that are mostly based on auscultation or cuff oscillometric principles do provide relatively accurate measurement of blood pressure. However, they mostly involve physical inconveniences such as pressure or stress on the human body. Here, we introduce a new non-invasive mechanism of tissue-informative measurement, where an experimental phenomenon called subcutaneous tissue pressure equilibrium is revealed and related for application in detection of absolute blood pressure. A prototype was experimentally verified to provide an absolute blood pressure measurement by wearing a watch-type measurement module that does not cause any discomfort. This work is supposed to contribute remarkably to the advancement of continuous non-invasive mobile devices for 24-7 daily-life ambulatory blood-pressure monitoring.
William J. Zielinski; Fredrick V. Schlexer; T. Luke George; Kristine L. Pilgrim; Michael K. Schwartz
2013-01-01
The Point Arena mountain beaver (Aplodontia rufa nigra) is federally listed as an endangered subspecies that is restricted to a small geographic range in coastal Mendocino County, California. Management of this imperiled taxon requires accurate information on its demography and vital rates. We developed noninvasive survey methods, using hair snares to sample DNA and to...
Yokota, M; Karis, A J; Tharion, W J
2014-01-01
Background: Thermal safety standards for the use of chemical, biological, radiological, and nuclear (CBRN) ensembles have been established for various US occupations, but not for law enforcement personnel. Objectives: We examined thermal strain levels of 30 male US law enforcement personnel who participated in CBRN field training in Arizona, Florida, and Massachusetts. Methods: Physiological responses were examined using unobtrusive heart rate (HR) monitors and a simple thermoregulatory model to predict core temperature (Tc) using HR and environment. Results: Thermal strain levels varied by environments, activity levels, and type of CBRN ensemble. Arizona and Florida volunteers working in hot-dry and hot-humid environment indicated high heat strain (predicted max Tc>38.5°C). The cool environment of Massachusetts reduced thermal strain although thermal strains were occasionally moderate. Conclusions: The non-invasive method of using physiological monitoring and thermoregulatory modeling could improve law enforcement mission to reduce the risk of heat illness or injury. PMID:24999847
NASA Astrophysics Data System (ADS)
Nishidate, Izumi; Wiswadarma, Aditya; Hase, Yota; Tanaka, Noriyuki; Maeda, Takaaki; Niizeki, Kyuichi; Aizu, Yoshihisa
2011-08-01
In order to visualize melanin and blood concentrations and oxygen saturation in human skin tissue, a simple imaging technique based on multispectral diffuse reflectance images acquired at six wavelengths (500, 520, 540, 560, 580 and 600nm) was developed. The technique utilizes multiple regression analysis aided by Monte Carlo simulation for diffuse reflectance spectra. Using the absorbance spectrum as a response variable and the extinction coefficients of melanin, oxygenated hemoglobin, and deoxygenated hemoglobin as predictor variables, multiple regression analysis provides regression coefficients. Concentrations of melanin and total blood are then determined from the regression coefficients using conversion vectors that are deduced numerically in advance, while oxygen saturation is obtained directly from the regression coefficients. Experiments with a tissue-like agar gel phantom validated the method. In vivo experiments with human skin of the human hand during upper limb occlusion and of the inner forearm exposed to UV irradiation demonstrated the ability of the method to evaluate physiological reactions of human skin tissue.
Anthropometry of external auditory canal by non-contactable measurement.
Yu, Jen-Fang; Lee, Kun-Che; Wang, Ren-Hung; Chen, Yen-Sheng; Fan, Chun-Chieh; Peng, Ying-Chin; Tu, Tsung-Hsien; Chen, Ching-I; Lin, Kuei-Yi
2015-09-01
Human ear canals cannot be measured directly with existing general measurement tools. Furthermore, general non-contact optical methods can only conduct simple peripheral measurements of the auricle and cannot obtain the internal ear canal shape-related measurement data. Therefore, this study uses the computed tomography (CT) technology to measure the geometric shape of the ear canal and the shape of the ear canal using a non-invasive method, and to complete the anthropometry of external auditory canal. The results of the study show that the average height and width of ear canal openings, and the average depth of the first bend for men are generally longer, wider and deeper than those for women. In addition, the difference between the height and width of the ear canal opening is about 40% (p < 0.05). Hence, the circular cross-section shape of the earplugs should be replaced with an elliptical cross-section shape during manufacturing for better fitting. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokorny, M.; Rebicek, J.; Klemes, J.
2015-10-15
This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axismore » of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time.« less
Molteni, Matteo; Magatti, Davide; Cardinali, Barbara; Rocco, Mattia; Ferri, Fabio
2013-01-01
The average pore size ξ0 of filamentous networks assembled from biological macromolecules is one of the most important physical parameters affecting their biological functions. Modern optical methods, such as confocal microscopy, can noninvasively image such networks, but extracting a quantitative estimate of ξ0 is a nontrivial task. We present here a fast and simple method based on a two-dimensional bubble approach, which works by analyzing one by one the (thresholded) images of a series of three-dimensional thin data stacks. No skeletonization or reconstruction of the full geometry of the entire network is required. The method was validated by using many isotropic in silico generated networks of different structures, morphologies, and concentrations. For each type of network, the method provides accurate estimates (a few percent) of the average and the standard deviation of the three-dimensional distribution of the pore sizes, defined as the diameters of the largest spheres that can be fit into the pore zones of the entire gel volume. When applied to the analysis of real confocal microscopy images taken on fibrin gels, the method provides an estimate of ξ0 consistent with results from elastic light scattering data. PMID:23473499
Papanicolaou, Andrew C; Rezaie, Roozbeh; Narayana, Shalini; Choudhri, Asim F; Abbas-Babajani-Feremi; Boop, Frederick A; Wheless, James W
2018-05-01
Cortical Stimulation Mapping (CSM) and the Wada procedure have long been considered the gold standard for localizing motor and language-related cortical areas and for determining the language and memory-dominant hemisphere, respectively. In recent years, however, non-invasive methods such as magnetoencephalography (MEG), functional magnetic resonance imaging (fMRI), and transcranial magnetic stimulation (TMS) have emerged as promising alternatives to the aforementioned procedures, particularly in cases where the invasive localization of eloquent cortex has proven to be challenging. To illustrate this point, we will first introduce the evidence of the compatibility of invasive and non-invasive methods and subsequently outline the rationale and the conditions where the latter methods are applicable. Copyright © 2017 Elsevier B.V. All rights reserved.
Non-Invasive markers for hepatic fibrosis
2011-01-01
With great advancements in the therapeutic modalities used for the treatment of chronic liver diseases, the accurate assessment of liver fibrosis is a vital need for successful individualized management of disease activity in patients. The lack of accurate, reproducible and easily applied methods for fibrosis assessment has been the major limitation in both the clinical management and for research in liver diseases. However, the problem of the development of biomarkers capable of non-invasive staging of fibrosis in the liver is difficult due to the fact that the process of fibrogenesis is a component of the normal healing response to injury, invasion by pathogens, and many other etiologic factors. Current non-invasive methods range from serum biomarker assays to advanced imaging techniques such as transient elastography and magnetic resonance imaging (MRI). Among non-invasive methods that gain strongest clinical foothold are FibroScan elastometry and serum-based APRI and FibroTest. There are many other tests that are not yet widely validated, but are none the less, promising. The rate of adoption of non-invasive diagnostic tests for liver fibrosis differs from country to country, but remains limited. At the present time, use of non-invasive procedures could be recommended as pre-screening that may allow physicians to narrow down the patients' population before definitive testing of liver fibrosis by biopsy of the liver. This review provides a systematic overview of these techniques, as well as both direct and indirect biomarkers based approaches used to stage fibrosis and covers recent developments in this rapidly advancing area. PMID:21849046
Neonatal Ear Molding: Timing and Technique.
Anstadt, Erin Elizabeth; Johns, Dana Nicole; Kwok, Alvin Chi-Ming; Siddiqi, Faizi; Gociman, Barbu
2016-03-01
The incidence of auricular deformities is believed to be ∼11.5 per 10,000 births, excluding children with microtia. Although not life-threatening, auricular deformities can cause undue distress for patients and their families. Although surgical procedures have traditionally been used to reconstruct congenital auricular deformities, ear molding has been gaining acceptance as an efficacious, noninvasive alternative for the treatment of newborns with ear deformations. We present the successful correction of bilateral Stahl's ear deformity in a newborn through a straightforward, nonsurgical method implemented on the first day of life. The aim of this report is to make pediatric practitioners aware of an effective and simple molding technique appropriate for correction of congenital auricular anomalies. In addition, it stresses the importance of very early initiation of ear cartilage molding for achieving the desired outcome. Copyright © 2016 by the American Academy of Pediatrics.
Electroencephalography as a post-stroke assessment method: An updated review.
Monge-Pereira, E; Molina-Rueda, F; Rivas-Montero, F M; Ibáñez, J; Serrano, J I; Alguacil-Diego, I M; Miangolarra-Page, J C
Given that stroke is currently a serious problem in the population, employing more reliable and objective techniques for determining diagnosis and prognosis is necessary in order to enable effective clinical decision-making. EEG is a simple, low-cost, non-invasive tool that can provide information about the changes occurring in the cerebral cortex during the recovery process after stroke. EEG provides data on the evolution of cortical activation patterns which can be used to establish a prognosis geared toward harnessing each patient's full potential. This strategy can be used to prevent compensation and maladaptive plasticity, redirect treatments, and develop new interventions that will let stroke patients reach their new maximum motor levels. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Capi text V.1--data analysis software for nailfold skin capillaroscopy.
Dobrev, Hristo P
2007-01-01
Nailfold skin capillaroscopy is a simple non-invasive method used to assess conditions of disturbed microcirculation such as Raynaud's phenomenon, acrocyanosis, perniones, connective tissue diseases, psoriasis, diabetes mellitus, neuropathy and vibration disease. To develop data analysis software aimed at assisting the documentation and analysis of a capillaroscopic investigation. SOFTWARE DESCRIPTION: The programme is based on a modular principle. The module "Nomenclatures" includes menus for the patients' data. The module "Examinations" includes menus for all general and specific aspects of the medical examination and capillaroscopic investigations. The modules "Settings" and "Information" include customization menus for the programme. The results of nailfold capillaroscopy can be printed in a short or expanded form. This software allows physicians to perform quick search by using various specified criteria and prepare analyses and reports. This software programme will facilitate any practitioner who performs nailfold skin capillaroscopy.
NASA Astrophysics Data System (ADS)
Manfredi, Marcello; Barberis, Elettra; Aceto, Maurizio; Marengo, Emilio
2017-06-01
During the last years the need for non-invasive and non-destructive analytical methods brought to the development and application of new instrumentation and analytical methods for the in-situ analysis of cultural heritage objects. In this work we present the application of a portable diffuse reflectance infrared Fourier transform (DRIFT) method for the non-invasive characterization of colorants prepared according to ancient recipes and using egg white and Gum Arabic as binders. Approximately 50 colorants were analyzed with the DRIFT spectroscopy: we were able to identify and discriminate the most used yellow (i.e. yellow ochres, Lead-tin Yellow, Orpiment, etc.), red (i.e. red ochres, Hematite) and blue (i.e. Lapis Lazuli, Azurite, indigo) colorants, creating a complete DRIFT spectral library. The Principal Component Analysis-Discriminant Analysis (PCA-DA) was then employed for the colorants classification according to the chemical/mineralogical composition. The DRIFT analysis was also performed on a gouache painting of the artist Sutherland; and the colorants used by the painter were identified directly in-situ and in a non-invasive manner.
Noninvasive glucose monitoring by optical reflective and thermal emission spectroscopic measurements
NASA Astrophysics Data System (ADS)
Saetchnikov, V. A.; Tcherniavskaia, E. A.; Schiffner, G.
2005-08-01
Noninvasive method for blood glucose monitoring in cutaneous tissue based on reflective spectrometry combined with a thermal emission spectroscopy has been developed. Regression analysis, neural network algorithms and cluster analysis are used for data processing.
Non-invasive acoustic-based monitoring of uranium in solution and H/D ratio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pantea, Cristian; Beedle, Christopher Craig; Sinha, Dipen N.
The primary objective of this project is to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of demonstrating the ability to quantify U or H/D ratios in solution. Furthermore, a successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended uranium mass measurements for International Atomic Energy Agency (IAEA).
Ståhlberg, Anders; Krzyzanowski, Paul M; Jackson, Jennifer B; Egyud, Matthew; Stein, Lincoln; Godfrey, Tony E
2016-06-20
Detection of cell-free DNA in liquid biopsies offers great potential for use in non-invasive prenatal testing and as a cancer biomarker. Fetal and tumor DNA fractions however can be extremely low in these samples and ultra-sensitive methods are required for their detection. Here, we report an extremely simple and fast method for introduction of barcodes into DNA libraries made from 5 ng of DNA. Barcoded adapter primers are designed with an oligonucleotide hairpin structure to protect the molecular barcodes during the first rounds of polymerase chain reaction (PCR) and prevent them from participating in mis-priming events. Our approach enables high-level multiplexing and next-generation sequencing library construction with flexible library content. We show that uniform libraries of 1-, 5-, 13- and 31-plex can be generated. Utilizing the barcodes to generate consensus reads for each original DNA molecule reduces background sequencing noise and allows detection of variant alleles below 0.1% frequency in clonal cell line DNA and in cell-free plasma DNA. Thus, our approach bridges the gap between the highly sensitive but specific capabilities of digital PCR, which only allows a limited number of variants to be analyzed, with the broad target capability of next-generation sequencing which traditionally lacks the sensitivity to detect rare variants. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.
Vahidroodsari, Fatemeh; Ayati, Seddigheh; Yousefi, Zohreh; Saeed, Shohreh
2010-01-01
Despite the important implication for women's health and reproduction, very few studies have focused on vaginal PH for menopausal diagnosis. Recent studies have suggested vaginal PH as a simple, noninvasive and inexpensive method for this purpose. The aim of this study is to compare serum FSH level with vaginal PH in menopause. This is a cross-sectional, descriptive study, conducted on 103 women (aged 31-95 yrs) with menopausal symptoms who were referred to the Menopausal Clinic at Ghaem Hospital during 2006. Vaginal pH was measured using pH meter strips and serum FSH levels were measured using immunoassay methods. The data was analyzed using SPSS software (version 11.5) and results were evaluated statistically by the Chi-square and Kappa tests. p≤0.05 was considered statistically significant. According to this study, in the absence of vaginal infection, the average vaginal pH in these 103 menopausal women was 5.33±0.53. If the menopausal hallmark was considered as vaginal pH>4.5, and serum FSH as ≥20 mIU/ml, then the sensitivity of vaginal pH for menopausal diagnosis was 97%. The mean of FSH levels in this population was 80.79 mIU/ml. Vaginal pH is a simple, accurate, and cost effective tool that can be suggested as a suitable alternative to serum FSH measurement for the diagnosis of menopause.
Nanri, Akiko; Nakagawa, Tohru; Kuwahara, Keisuke; Yamamoto, Shuichiro; Honda, Toru; Okazaki, Hiroko; Uehara, Akihiko; Yamamoto, Makoto; Miyamoto, Toshiaki; Kochi, Takeshi; Eguchi, Masafumi; Murakami, Taizo; Shimizu, Chii; Shimizu, Makiko; Tomita, Kentaro; Nagahama, Satsue; Imai, Teppei; Nishihara, Akiko; Sasaki, Naoko; Hori, Ai; Sakamoto, Nobuaki; Nishiura, Chihiro; Totsuzaki, Takafumi; Kato, Noritada; Fukasawa, Kenji; Huanhuan, Hu; Akter, Shamima; Kurotani, Kayo; Kabe, Isamu; Mizoue, Tetsuya; Sone, Tomofumi; Dohi, Seitaro
2015-01-01
Risk models and scores have been developed to predict incidence of type 2 diabetes in Western populations, but their performance may differ when applied to non-Western populations. We developed and validated a risk score for predicting 3-year incidence of type 2 diabetes in a Japanese population. Participants were 37,416 men and women, aged 30 or older, who received periodic health checkup in 2008-2009 in eight companies. Diabetes was defined as fasting plasma glucose (FPG) ≥ 126 mg/dl, random plasma glucose ≥ 200 mg/dl, glycated hemoglobin (HbA1c) ≥ 6.5%, or receiving medical treatment for diabetes. Risk scores on non-invasive and invasive models including FPG and HbA1c were developed using logistic regression in a derivation cohort and validated in the remaining cohort. The area under the curve (AUC) for the non-invasive model including age, sex, body mass index, waist circumference, hypertension, and smoking status was 0.717 (95% CI, 0.703-0.731). In the invasive model in which both FPG and HbA1c were added to the non-invasive model, AUC was increased to 0.893 (95% CI, 0.883-0.902). When the risk scores were applied to the validation cohort, AUCs (95% CI) for the non-invasive and invasive model were 0.734 (0.715-0.753) and 0.882 (0.868-0.895), respectively. Participants with a non-invasive score of ≥ 15 and invasive score of ≥ 19 were projected to have >20% and >50% risk, respectively, of developing type 2 diabetes within 3 years. The simple risk score of the non-invasive model might be useful for predicting incident type 2 diabetes, and its predictive performance may be markedly improved by incorporating FPG and HbA1c.
Hutzler, Michael; Fromherz, Peter
2004-04-01
Probing projections between brain areas and their modulation by synaptic potentiation requires dense arrays of contacts for noninvasive electrical stimulation and recording. Semiconductor technology is able to provide planar arrays with high spatial resolution to be used with planar neuronal structures such as organotypic brain slices. To address basic methodical issues we developed a silicon chip with simple arrays of insulated capacitors and field-effect transistors for stimulation of neuronal activity and recording of evoked field potentials. Brain slices from rat hippocampus were cultured on that substrate. We achieved local stimulation of the CA3 region by applying defined voltage pulses to the chip capacitors. Recording of resulting local field potentials in the CA1 region was accomplished with transistors. The relationship between stimulation and recording was rationalized by a sheet conductor model. By combining a row of capacitors with a row of transistors we determined a simple stimulus-response matrix from CA3 to CA1. Possible contributions of inhomogeneities of synaptic projection, of tissue structure and of neuroelectronic interfacing were considered. The study provides the basis for a development of semiconductor chips with high spatial resolution that are required for long-term studies of topographic mapping.
Measurement of jaw motion: the proposal of a simple and accurate method.
Pinheiro, A P; Pereira, A A; Andrade, A O; Bellomo, D
2011-01-01
The analysis of jaw movements has long been used as a measure for clinical diagnosis and assessment. A number of strategies are available for monitoring the trajectory; however most of these strategies make use of expensive tools, which are often not available to many clinics in the world. In this context, this research proposes the development of a new tool capable of quantifying the movements of opening/closing, protrusion and laterotrusion of the mandible. These movements are important for the clinical evaluation of both the temporomandibular function and muscles involved in mastication. The proposed system, unlike current commercial systems, employs a low-cost video camera and a computer program, which is used for reconstructing the trajectory of a reflective marker that is fixed on the jaw. In order to illustrate the application of the devised tool a clinical trial was carried out, investigating jaw movements of 10 subjects. The results obtained in this study were compatible with those found in the literature with the advantage of using a low-cost, simple, non-invasive and flexible solution customized for the practical needs of clinics. The average error of the system was less than 1.0%.
NASA Astrophysics Data System (ADS)
Dowden, B. R.; Frankel, M. A.; Normann, R. A.; Clark, G. A.
2012-02-01
High-channel-count intrafascicular electrode arrays provide comprehensive and selective access to the peripheral nervous system. One practical difficulty in using several electrode arrays to evoke coordinated movements in paralyzed limbs is the identification of the appropriate stimulation channels and stimulus parameters to evoke desired movements. Here we present the use of a six degree-of-freedom load cell placed under the foot of a feline to characterize the muscle activation produced by three 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted into the femoral nerves, sciatic nerves, and muscular branches of the sciatic nerves of three cats. Intramuscular stimulation was used to identify the endpoint force directions produced by 15 muscles of the hind limb, and these directions were used to classify the forces produced by each intrafascicular USEA electrode as flexion or extension. For 451 USEA electrodes, stimulus intensities for threshold and saturation muscle forces were identified, and the 3D direction and linearity of the force recruitment curves were determined. Further, motor unit excitation independence for 198 electrode pairs was measured using the refractory technique. This study demonstrates the utility of 3D endpoint force monitoring as a simple and non-invasive metric for characterizing the muscle-activation properties of hundreds of implanted peripheral nerve electrodes, allowing for electrode and parameter selection for neuroprosthetic applications.
Ren, Jimin; Dean Sherry, A; Malloy, Craig R
2013-09-01
Despite its importance in energy metabolism, lactate in human skeletal muscle has been difficult to detect by noninvasive (1)H-magnetic resonance spectroscopy mainly due to interference from large water and lipid signals. Long echo-time acquisitions at 7 T effectively attenuates the water and lipid signals in forearm muscle allowing direct observation of both lactate resonances, the methine at 4.09 ppm and the methyl at 1.31 ppm. Using this approach, we were able to monitor lactate dynamics at a temporal resolution of 32 s. While lactate was not detectable at rest, immediately after an acute period of exercise to fatigue the forearm muscle, lactate rose to a level comparable to that of creatine (∼30 mmol/kg wet weight). In a typical (1)H-magnetic resonance spectrum collected using a echo-time of 140 ms, the lactate methine and methyl resonances both appear as doublets with an unusually large splitting of ∼20 Hz due to residual dipolar coupling. During muscle recovery following exercise, the lactate signals decay rapidly with a time constant of t½ = 2.0 ± 0.6 min (n = 12 subjects). This fast and simple lactate detection method may prove valuable for monitoring lactate metabolism in cancer and in sports medicine applications. Copyright © 2012 Wiley Periodicals, Inc.
El Khattabi, Laïla Allach; Rouillac-Le Sciellour, Christelle; Le Tessier, Dominique; Luscan, Armelle; Coustier, Audrey; Porcher, Raphael; Bhouri, Rakia; Nectoux, Juliette; Sérazin, Valérie; Quibel, Thibaut; Mandelbrot, Laurent; Tsatsaris, Vassilis
2016-01-01
Objective NIPT for fetal aneuploidy by digital PCR has been hampered by the large number of PCR reactions needed to meet statistical requirements, preventing clinical application. Here, we designed an octoplex droplet digital PCR (ddPCR) assay which allows increasing the number of available targets and thus overcomes statistical obstacles. Method After technical optimization of the multiplex PCR on mixtures of trisomic and euploid DNA, we performed a validation study on samples of plasma DNA from 213 pregnant women. Molecular counting of circulating cell-free DNA was performed using a mix of hydrolysis probes targeting chromosome 21 and a reference chromosome. Results The results of our validation experiments showed that ddPCR detected trisomy 21 even when the sample’s trisomic DNA content is as low as 5%. In a validation study of plasma samples from 213 pregnant women, ddPCR discriminated clearly between the trisomy 21 and the euploidy groups. Conclusion Our results demonstrate that digital PCR can meet the requirements for non-invasive prenatal testing of trisomy 21. This approach is technically simple, relatively cheap, easy to implement in a diagnostic setting and compatible with ethical concerns regarding access to nucleotide sequence information. These advantages make it a potential technique of choice for population-wide screening for trisomy 21 in pregnant women. PMID:27167625
High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes.
Walk, Elyse L; McLaughlin, Sarah L; Weed, Scott A
2015-07-25
High-frequency ultrasound (HFUS) is widely employed as a non-invasive method for imaging internal anatomic structures in experimental small animal systems. HFUS has the ability to detect structures as small as 30 µm, a property that has been utilized for visualizing superficial lymph nodes in rodents in brightness (B)-mode. Combining power Doppler with B-mode imaging allows for measuring circulatory blood flow within lymph nodes and other organs. While HFUS has been utilized for lymph node imaging in a number of mouse model systems, a detailed protocol describing HFUS imaging and characterization of the cervical lymph nodes in mice has not been reported. Here, we show that HFUS can be adapted to detect and characterize cervical lymph nodes in mice. Combined B-mode and power Doppler imaging can be used to detect increases in blood flow in immunologically-enlarged cervical nodes. We also describe the use of B-mode imaging to conduct fine needle biopsies of cervical lymph nodes to retrieve lymph tissue for histological analysis. Finally, software-aided steps are described to calculate changes in lymph node volume and to visualize changes in lymph node morphology following image reconstruction. The ability to visually monitor changes in cervical lymph node biology over time provides a simple and powerful technique for the non-invasive monitoring of cervical lymph node alterations in preclinical mouse models of oral cavity disease.
Dowden, B R; Frankel, M A; Normann, R A; Clark, G A
2012-02-01
High-channel-count intrafascicular electrode arrays provide comprehensive and selective access to the peripheral nervous system. One practical difficulty in using several electrode arrays to evoke coordinated movements in paralyzed limbs is the identification of the appropriate stimulation channels and stimulus parameters to evoke desired movements. Here we present the use of a six degree-of-freedom load cell placed under the foot of a feline to characterize the muscle activation produced by three 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted into the femoral nerves, sciatic nerves, and muscular branches of the sciatic nerves of three cats. Intramuscular stimulation was used to identify the endpoint force directions produced by 15 muscles of the hind limb, and these directions were used to classify the forces produced by each intrafascicular USEA electrode as flexion or extension. For 451 USEA electrodes, stimulus intensities for threshold and saturation muscle forces were identified, and the 3D direction and linearity of the force recruitment curves were determined. Further, motor unit excitation independence for 198 electrode pairs was measured using the refractory technique. This study demonstrates the utility of 3D endpoint force monitoring as a simple and non-invasive metric for characterizing the muscle-activation properties of hundreds of implanted peripheral nerve electrodes, allowing for electrode and parameter selection for neuroprosthetic applications.
Xiao, Guangqin; Zhu, Sixian; Xiao, Xiao; Yan, Lunan; Yang, Jiayin; Wu, Gang
2017-11-01
Many noninvasive methods for diagnosing liver fibrosis (LF) have been proposed. To determine the best method for diagnosing LF in nonalcoholic fatty liver disease (NAFLD), we conducted a systemic review and meta-analysis to compare the performance of aspartate aminotransferase to platelets ratio index (APRI), fibrosis-4 index (FIB-4), BARD score, NAFLD fibrosis score (NFS), FibroScan, shear wave elastography (SWE), and magnetic resonance elastography (MRE) for diagnosing LF in NAFLD. We compared the sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUROC) of these noninvasive methods for detecting significant fibrosis (SF), advanced fibrosis (AF), and cirrhosis. Heterogeneity was explored using meta-regression. Sixty-four articles with a total of 13,046 NAFLD subjects were included. The overall mean prevalence of SF, AF, and cirrhosis was 45.0%, 24.0%, and 9.4% in NAFLD patients, respectively. With an APRI threshold of 1.0 and 1.5, the sensitivities and specificities were 50.0% and 84.0% and 18.3% and 96.1%, respectively, for AF. With a FIB-4 threshold of 2.67 and 3.25, the sensitivities and specificities were 26.6% and 96.5% and 31.8% and 96.0%, respectively, for AF. The summary sensitivities and specificities of BARD score (threshold of 2), NFS (threshold of -1.455), FibroScan M (threshold of 8.7-9), SWE, and MRE for detecting AF were 0.76 and 0.61, 0.72 and 0.70, 0.87 and 0.79, 0.90 and 0.93, and 0.84 and 0.90, respectively. The summary AUROC values using APRI, FIB-4, BARD score, NFS, FibroScan M probe, XL probe, SWE, and MRE for diagnosing AF were 0.77, 0.84, 0.76, 0.84, 0.88, 0.85, 0.95, and 0.96, respectively. MRE and SWE may have the highest diagnostic accuracy for staging fibrosis in NAFLD patients. Among the four noninvasive simple indexes, NFS and FIB-4 probably offer the best diagnostic performance for detecting AF. (Hepatology 2017;66:1486-1501). © 2017 by the American Association for the Study of Liver Diseases.
Noninvasive metabolic profiling for painless diagnosis of human diseases and disorders.
Mal, Mainak
2016-06-01
Metabolic profiling provides a powerful diagnostic tool complementary to genomics and proteomics. The pain, discomfort and probable iatrogenic injury associated with invasive or minimally invasive diagnostic methods, render them unsuitable in terms of patient compliance and participation. Metabolic profiling of biomatrices like urine, breath, saliva, sweat and feces, which can be collected in a painless manner, could be used for noninvasive diagnosis. This review article covers the noninvasive metabolic profiling studies that have exhibited diagnostic potential for diseases and disorders. Their potential applications are evident in different forms of cancer, metabolic disorders, infectious diseases, neurodegenerative disorders, rheumatic diseases and pulmonary diseases. Large scale clinical validation of such diagnostic methods is necessary in future.
Noninvasive metabolic profiling for painless diagnosis of human diseases and disorders
Mal, Mainak
2016-01-01
Metabolic profiling provides a powerful diagnostic tool complementary to genomics and proteomics. The pain, discomfort and probable iatrogenic injury associated with invasive or minimally invasive diagnostic methods, render them unsuitable in terms of patient compliance and participation. Metabolic profiling of biomatrices like urine, breath, saliva, sweat and feces, which can be collected in a painless manner, could be used for noninvasive diagnosis. This review article covers the noninvasive metabolic profiling studies that have exhibited diagnostic potential for diseases and disorders. Their potential applications are evident in different forms of cancer, metabolic disorders, infectious diseases, neurodegenerative disorders, rheumatic diseases and pulmonary diseases. Large scale clinical validation of such diagnostic methods is necessary in future. PMID:28031956
Method for Non-Invasive Determination of Chemical Properties of Aqueous Solutions
NASA Technical Reports Server (NTRS)
Jones, Alan (Inventor); Thomas, Nathan A. (Inventor); Todd, Paul W. (Inventor)
2016-01-01
A method for non-invasively determining a chemical property of an aqueous solution is provided. The method provides the steps of providing a colored solute having a light absorbance spectrum and transmitting light through the colored solute at two different wavelengths. The method further provides the steps of measuring light absorbance of the colored solute at the two different transmitted light wavelengths, and comparing the light absorbance of the colored solute at the two different wavelengths to determine a chemical property of an aqueous solution.
Routine blood tests to predict liver fibrosis in chronic hepatitis C.
Hsieh, Yung-Yu; Tung, Shui-Yi; Lee, Kamfai; Wu, Cheng-Shyong; Wei, Kuo-Liang; Shen, Chien-Heng; Chang, Te-Sheng; Lin, Yi-Hsiung
2012-02-28
To verify the usefulness of FibroQ for predicting fibrosis in patients with chronic hepatitis C, compared with other noninvasive tests. This retrospective cohort study included 237 consecutive patients with chronic hepatitis C who had undergone percutaneous liver biopsy before treatment. FibroQ, aspartate aminotransferase (AST)/alanine aminotransferase ratio (AAR), AST to platelet ratio index, cirrhosis discriminant score, age-platelet index (API), Pohl score, FIB-4 index, and Lok's model were calculated and compared. FibroQ, FIB-4, AAR, API and Lok's model results increased significantly as fibrosis advanced (analysis of variance test: P < 0.001). FibroQ trended to be superior in predicting significant fibrosis score in chronic hepatitis C compared with other noninvasive tests. FibroQ is a simple and useful test for predicting significant fibrosis in patients with chronic hepatitis C.
Ultrasonography for Noninvasive Assessment of Portal Hypertension
Maruyama, Hitoshi; Yokosuka, Osamu
2017-01-01
Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension. PMID:28267700
Ultrasonography for Noninvasive Assessment of Portal Hypertension.
Maruyama, Hitoshi; Yokosuka, Osamu
2017-07-15
Portal hypertension is a major pathophysiology in patients with cirrhosis. Portal pressure is the gold standard to evaluate the severity of portal hypertension, and radiological intervention is the only procedure for pressure measurement. Ultrasound (US) is a simple and noninvasive imaging modality available worldwide. B-mode imaging allows broad applications for patients to detect and characterize chronic liver diseases and focal hepatic lesions. The Doppler technique offers real-time observation of blood flow with qualitative and quantitative assessments, and the application of microbubble-based contrast agents has improved the detectability of peripheral blood flow. In addition, elastography for the liver and spleen covers a wider field beyond the original purpose of fibrosis assessment. These developments enhance the practical use of US in the evaluation of portal hemodynamic abnormalities. This article reviews the recent progress of US in the assessment of portal hypertension.
Comparison of fecal elastase-1 and pancreatic function testing in children.
Wali, Prateek D; Loveridge-Lenza, Beth; He, Zhaoping; Horvath, Karoly
2012-02-01
The fecal pancreatic elastase-1 (FE-1) test is considered a simple, noninvasive, indirect measure of pancreatic function. We aimed to evaluate the performance of the FE-1 test compared with the direct pancreatic function test (PFT) with secretin stimulation in children. Data of 70 children (6 months-17 years of age) who had both FE-1 test and PFT were analyzed. The average FE-1 concentration was 403 ± 142 μg/g. Eleven children had concentrations below 200 μg/g, 23 between 201 to 500 μg/g, and 36 were above 500 μg/g. The average pancreatic elastase activity measured on direct stimulation was 49.1 ± 38.6 μmol · min (-1)· ml(-1) and 11 children had activity below the established cutoff (10.5 μmol · min(-1) · ml(-1)). Among the 11 children with pathologic PFT, 7 had normal FE-1, 4 were in the intermediate range (201-500 μg/g), and none were in the low range (<200 μg/g). Among the 59 children with normal direct PFT 11 (19%) had pathologic (<200 μg/g) and 19 (32%) had intermediate FE-1 tests. Twenty-nine children had both normal FE-1 concentration and normal PFT, giving a negative predictive value of 80%. The correlation between pancreatic elastase activity and FE-1 concentration was poor (r = 0.190). The sensitivity of the FE-1 test was found to be 41.7%, whereas the specificity was 49.2%. The positive predictive value of the FE-1 test was only 14%. The FE-1 test is a simple, noninvasive, indirect method; however, ordering physicians should be aware of its limitations. It can give false-positive results and has low sensitivity in children with mild pancreatic insufficiency without cystic fibrosis and in those with isolated pancreatic enzyme deficiencies.
Jellinger, Kurt A; Janetzky, Bernd; Attems, Johannes; Kienzl, Elisabeth
2008-08-01
Simple, non-invasive tests for an early detection of degenerative dementia by use of biomarkers are urgently required. However, up to the present, no validated extracerebral diagnostic markers (plasma/serum, platelets, urine, connective tissue) for the early diagnosis of Alzheimer disease (AD) are available. In disease stages with evident cognitive disturbances, the clinical diagnosis of probable AD is made with around 90% accuracy using modern clinical, neuropsychological and imaging methods. Diagnostic sensitivity and specificity even in early disease stages are improved by CSF markers, in particular combined tau and amyloid beta peptides (Abeta) and plasma markers (eg, Abeta-42/Abeta-40 ratio). Recently, a novel gene/protein--ALZAS (Alzheimer Associated Protein)--with a 79 amino acid sequence, containing the amyloid beta-42 fragment (Abeta-42), the amyloid precursor protein (APP) transmembrane signal and a 12 amino acid C-terminal, not present in any other known APP alleles, has been discovered on chromosome 21 within the APP region. Reverse transcriptase-PCR revealed the expression of the transcript of this protein in the cortex and hippocampal regions as well as in lymphocytes of human AD patients. The expression of ALZAS is mirrored by a specific autoimmune response in AD patients, directed against the ct-12 end of the ALZAS-peptide but not against the Abeta-sequence. ELISA studies of plasma detected highest titers of ALZAS in patients with mild cognitive impairment (presymptomatic AD), but only moderately increased titers in autopsy-confirmed AD, whereas low or undetectable ct-12 titers were found in cognitively intact age-matched subjects and young controls. The antigen, ALZAS protein, was detected in plasma in later clinical stages of AD. It is suggested that ALZAS represents an indicator in a dynamic equilibrium between both peripheral and brain degenerative changes in AD and may become a useful "non-invasive" diagnostic marker via a simple blood test.
NASA Astrophysics Data System (ADS)
Zhang, Ying; Zhang, Xiyang; Li, Zhifang; Li, Hui
2016-10-01
Blood glucose concentration measurement is essential for the diagnosis and treatment of diabetes. However, conventional glucose measurement methods are invasive and not suitable for real-time monitoring. This study demonstrated a noninvasive blood glucose measurement method using optical coherence tomography to image human lip in vivo. Optical coherence tomography (OCT) is a noninvasive and depth-resolved technique capable of acquiring tissue structure images in real time. Human lip has very thin skin and is full of blood vessels, which is appropriate for noninvasive glucose measurement. To verify the feasibility of OCT for glucose concentration monitoring, two groups of OCT imaging data were obtained from human lips of normal people. In one group, OCT images of lip were acquired from people on an empty stomach. In the other group, the same sites of lip were observed by OCT 2 hours after breakfast. Evident differences were found from two groups of OCT images that correspond to preprandial glucose and 2- hour postprandial glucose, respectively. The relationship between OCT image and blood glucose concentration was investigated. The result indicates that OCT possesses considerable prospects in terms of noninvasive blood glucose measurement.
Hsieh, Chung-Bao; Chen, Chung-Jueng; Chen, Teng-Wei; Yu, Jyh-Cherng; Shen, Kuo-Liang; Chang, Tzu-Ming; Liu, Yao-Chi
2004-01-01
AIM: To investigate whether the non-invasive real-time Indocynine green (ICG) clearance is a sensitive index of liver viability in patients before, during, and after liver transplantation. METHODS: Thirteen patients were studied, two before, three during, and eight following liver transplantation, with two patients suffering acute rejection. The conventional invasive ICG clearance test and ICG pulse spectrophotometry non-invasive real-time ICG clearance test were performed simultaneously. Using linear regression analysis we tested the correlation between these two methods. The transplantation condition of these patients and serum total bilirubin (T. Bil), alanine aminotransferase (ALT), and platelet count were also evaluated. RESULTS: The correlation between these two methods was excellent (r2 = 0.977). CONCLUSION: ICG pulse spectrophotometry clearance is a quick, non-invasive, and reliable liver function test in transplantation patients. PMID:15285026
Noninvasive esthetic treatment for hypomaturation amelogenesis imperfecta: a case report.
Nahsan, Flávia Pardo Salata; Silva, Luciana Mendonça da; Lima, Thiago Mendes de; Bertocco, Verônica Pereira de Lima; Chui, Fabíola Mendonça da Silva; Martins, Leandro de Moura
2016-01-01
Enamel alterations, such as amelogenesis imperfecta, can compromise the harmony of the smile and the patient's self-esteem and may cause tooth sensitivity. A simple and effective treatment approach uses the natural stratification of composite resins to mask deficient enamel formation and mimic the natural appearance of the substrate. The operative steps and principles for restorative success are described in this case report with 36-month follow-up.
Non-invasive in vivo measurement of macular carotenoids
NASA Technical Reports Server (NTRS)
Lambert, James L. (Inventor); Borchert, Mark S. (Inventor)
2009-01-01
A non-invasive in vivo method for assessing macular carotenoids includes performing Optical Coherence Tomography (OCT) on a retina of a subject. A spatial representation of carotenoid levels in the macula based on data from the OCT of the retina can be generated.
Barg, Alexej; Saltzman, Charles L; Beals, Timothy C; Bachus, Kent N; Blankenhorn, Brad D; Nickisch, Florian
2016-07-01
To evaluate the accessibility of the talar dome through anterior and posterior portals for ankle arthroscopy with the standard noninvasive distraction versus wire-based longitudinal distraction using a tensioned wire placed transversely through the calcaneal tuberosity. Seven matched pairs of thigh-to-foot specimens underwent ankle arthroscopy with 1 of 2 methods of distraction: a standard noninvasive strapping technique or a calcaneal tuberosity wire-based technique. The order of the arthroscopic approach and use of a distraction method was randomly determined. The areas accessed from both 2-portal anterior and 2-portal posterior approaches were determined by using a molded translucent grid. The mean talar surface accessible by anterior ankle arthroscopy was comparable with noninvasive versus calcaneal wire distraction with 57.8% ± 17.2% (range, 32.9% to 75.7%) versus 61.5% ± 15.2% (range, 38.5% to 79.1%) of the talar dome, respectively (P = .590). The use of calcaneal wire distraction significantly improved posterior talar dome accessibility compared with noninvasive distraction, with 56.4% ± 20.0% (range, 14.4% to 78.0%) versus 39.8% ± 14.9% (range, 20.0% to 57.6%) of the talar dome, respectively (P = .031). Under the conditions studied, our cadaveric model showed equivalent talar dome access with 2-portal anterior arthroscopy of calcaneal wire-based distraction versus noninvasive strap distraction, but improved access for 2-portal posterior arthroscopy with calcaneal wire-based distraction versus noninvasive strap distraction. The posterior 40% of the talar dome is difficult to access via anterior ankle arthroscopy. Posterior calcaneal tuberosity wire-based longitudinal distraction improved arthroscopic access to the centro-posterior talar dome with a posterior arthroscopic approach. Published by Elsevier Inc.
Nonalcoholic steatohepatitis in bariatric patients with a diagnosis of obstructive sleep apnea.
Weingarten, Toby N; Mantilla, Carlos B; Swain, James M; Kendrick, Michael L; Oberhansley, Jeff M; Burcham, Robert J; Ribeiro, Tarsila C R; Watt, Kymberly D; Schroeder, Darrell R; Narr, Bradly J; Sprung, Juraj
2012-01-01
To study a possible association between obstructive sleep apnea (OSA) severity, managed with noninvasive ventilation, and nonalcoholic steatohepatitis (NASH) in bariatric surgical patients. Medical records of 218 bariatric surgical patients who underwent liver biopsy were reviewed. OSA severity was determined from preoperative polysomnography (apnea-hypopnea index (AHI) ≤ 15 no/mild OSA vs. AHI ≥ 16 moderate/severe OSA). Patients diagnosed with OSA were prescribed noninvasive ventilation. Patients were categorized according to liver histopathology into 3 groups: (i) no liver disease or simple steatosis, (ii) mild NASH (steatosis with necroinflammation and mild fibrosis (stage 0-1)), and iii) advanced NASH (steatosis with necroinflammation and more advanced fibrosis (stage ≥ 2)). 125 patients (57%) had no/mild OSA, and 93 (43%) had moderate/severe OSA. There was no difference in serum aminotransferases between patients by OSA severity classification. There was a high prevalence of hepatic histopathological abnormalities: 84% patients had steatosis, 57% had necroinflammation, 34% had fibrotic changes, and 14% had advanced NASH. There was no association between severity of NASH and severity of OSA. There is no association between stage of steatohepatitis and OSA severity among morbidly obese patients managed with noninvasive ventilation.
Clewett, Christopher J; Langley, Phillip; Bateson, Anthony D; Asghar, Aziz; Wilkinson, Antony J
2016-03-01
Hypoglycaemia unawareness is a common condition associated with increased risk of severe hypoglycaemia. The purpose of the authors' study was to develop a simple to use, home-based and non-invasive hypoglycaemia warning system based on electroencephalography (EEG), and to demonstrate its use in a single-case feasibility study. A participant with type 1 diabetes forms a single-person case study where blood sugar levels and EEG were recorded. EEG was recorded using skin surface electrodes placed behind the ear located within the T3 region by the participant in the home. EEG was analysed retrospectively to develop an algorithm which would trigger a warning if EEG changes associated with hypoglycaemia onset were detected. All hypoglycaemia events were detected by the EEG hypoglycaemia warning algorithm. Warnings were triggered with blood glucose concentration levels at or below 4.2 mmol/l in this participant and no warnings were issued when in euglycaemia. The feasibility of a non-invasive EEG-based hypoglycaemia warning system for personal monitoring in the home has been demonstrated in a single case study. The results suggest that further studies are warranted to evaluate the system prospectively in a larger group of participants.
Development of Novel Noninvasive Methods of Stress Assessment in Baleen Whales
2014-09-30
large whales. Few methods exist for assessment of physiological stress levels of free-swimming cetaceans (Amaral 2010, ONR 2010, Hunt et al. 2013...hormone aldosterone . Our aim in this project is to further develop both techniques - respiratory hormone analysis and fecal hormone analysis - for use...noninvasive aldosterone assay (for both feces and blow) that can be used as an alternative measure of adrenal gland activation relative to stress
Cho, Il Haeng; Park, Kyung S; Lim, Chang Joo
2010-02-01
In this study, we described the characteristics of five different biological age (BA) estimation algorithms, including (i) multiple linear regression, (ii) principal component analysis, and somewhat unique methods developed by (iii) Hochschild, (iv) Klemera and Doubal, and (v) a variant of Klemera and Doubal's method. The objective of this study is to find the most appropriate method of BA estimation by examining the association between Work Ability Index (WAI) and the differences of each algorithm's estimates from chronological age (CA). The WAI was found to be a measure that reflects an individual's current health status rather than the deterioration caused by a serious dependency with the age. Experiments were conducted on 200 Korean male participants using a BA estimation system developed principally under the concept of non-invasive, simple to operate and human function-based. Using the empirical data, BA estimation as well as various analyses including correlation analysis and discriminant function analysis was performed. As a result, it had been confirmed by the empirical data that Klemera and Doubal's method with uncorrelated variables from principal component analysis produces relatively reliable and acceptable BA estimates. 2009 Elsevier Ireland Ltd. All rights reserved.
Estimation of fish biomass using environmental DNA.
Takahara, Teruhiko; Minamoto, Toshifumi; Yamanaka, Hiroki; Doi, Hideyuki; Kawabata, Zen'ichiro
2012-01-01
Environmental DNA (eDNA) from aquatic vertebrates has recently been used to estimate the presence of a species. We hypothesized that fish release DNA into the water at a rate commensurate with their biomass. Thus, the concentration of eDNA of a target species may be used to estimate the species biomass. We developed an eDNA method to estimate the biomass of common carp (Cyprinus carpio L.) using laboratory and field experiments. In the aquarium, the concentration of eDNA changed initially, but reached an equilibrium after 6 days. Temperature had no effect on eDNA concentrations in aquaria. The concentration of eDNA was positively correlated with carp biomass in both aquaria and experimental ponds. We used this method to estimate the biomass and distribution of carp in a natural freshwater lagoon. We demonstrated that the distribution of carp eDNA concentration was explained by water temperature. Our results suggest that biomass data estimated from eDNA concentration reflects the potential distribution of common carp in the natural environment. Measuring eDNA concentration offers a non-invasive, simple, and rapid method for estimating biomass. This method could inform management plans for the conservation of ecosystems.
Estimation of Fish Biomass Using Environmental DNA
Takahara, Teruhiko; Minamoto, Toshifumi; Yamanaka, Hiroki; Doi, Hideyuki; Kawabata, Zen'ichiro
2012-01-01
Environmental DNA (eDNA) from aquatic vertebrates has recently been used to estimate the presence of a species. We hypothesized that fish release DNA into the water at a rate commensurate with their biomass. Thus, the concentration of eDNA of a target species may be used to estimate the species biomass. We developed an eDNA method to estimate the biomass of common carp (Cyprinus carpio L.) using laboratory and field experiments. In the aquarium, the concentration of eDNA changed initially, but reached an equilibrium after 6 days. Temperature had no effect on eDNA concentrations in aquaria. The concentration of eDNA was positively correlated with carp biomass in both aquaria and experimental ponds. We used this method to estimate the biomass and distribution of carp in a natural freshwater lagoon. We demonstrated that the distribution of carp eDNA concentration was explained by water temperature. Our results suggest that biomass data estimated from eDNA concentration reflects the potential distribution of common carp in the natural environment. Measuring eDNA concentration offers a non-invasive, simple, and rapid method for estimating biomass. This method could inform management plans for the conservation of ecosystems. PMID:22563411
A Simple Model for Nonlinear Confocal Ultrasonic Beams
NASA Astrophysics Data System (ADS)
Zhang, Dong; Zhou, Lin; Si, Li-Sheng; Gong, Xiu-Fen
2007-01-01
A confocally and coaxially arranged pair of focused transmitter and receiver represents one of the best geometries for medical ultrasonic imaging and non-invasive detection. We develop a simple theoretical model for describing the nonlinear propagation of a confocal ultrasonic beam in biological tissues. On the basis of the parabolic approximation and quasi-linear approximation, the nonlinear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation is solved by using the angular spectrum approach. Gaussian superposition technique is applied to simplify the solution, and an analytical solution for the second harmonics in the confocal ultrasonic beam is presented. Measurements are performed to examine the validity of the theoretical model. This model provides a preliminary model for acoustic nonlinear microscopy.
Reliable noninvasive measurement of blood gases
Thomas, Edward V.; Robinson, Mark R.; Haaland, David M.; Alam, Mary K.
1997-05-20
This invention relates to methods and apparatus for, preferably, determining non-invasively and in vivo at least two of the five blood gas parameters (i.e., pH, [HCO.sub.3.sup.- ], PCO.sub.2, PO.sub.2, and O.sub.2 sat.) in a human.
USDA-ARS?s Scientific Manuscript database
Most hosts are concurrently or sequentially infected with multiple parasites, thus fully understanding interactions between individual parasite species and their hosts depends on accurate characterization of the parasite community. For parasitic nematodes, non-invasive methods for obtaining quantita...
NONINVASIVE DETERMINATION OF RESPIRATORY OZONE ABSORPTION: THE BOLUS-RESPONSE METHOD
Dr. James Ultman and colleagues used a fast-responding ozone measurement system, which they had developed with previous HEI support, to noninvasively measure the absorption of inhaled ozone in different regions of the respiratory tract of healthy adult men. While the subjec...
Sensor system for non-invasive optical carboxy-and methemoglobin determination
NASA Astrophysics Data System (ADS)
Timm, Ulrich; Gewiss, Helge; Kraitl, Jens; Brock, Beate; Ewald, Hartmut
2017-02-01
The pulse oximetry is a non-invasive method to monitor the oxygen saturation and is clinically used for many years. However this technology has some limitations. In case of the presence of dysfunctional hemoglobin derivatives as carboxyhemoglobin (COHb) or methemoglobin (MetHb) the readings of the pulse oximeter are distorted. This erroneous diagnosis of the patient's status can result in a life threatening situation. This paper will describe a sensor system for noninvasive determination of carboxy- and methemoglobin.
Ultrasonic sensing for noninvasive characterization of oil-water-gas flow in a pipe
NASA Astrophysics Data System (ADS)
Chillara, Vamshi Krishna; Sturtevant, Blake T.; Pantea, Cristian; Sinha, Dipen N.
2017-02-01
A technique for noninvasive ultrasonic characterization of multiphase crude oil-water-gas flow is discussed. The proposed method relies on determining the sound speed in the mixture. First, important issues associated with making real-time noninvasive measurements are discussed. Then, signal processing approach adopted to determine the sound speed in the multiphase mixture is presented. Finally, results from controlled experiments on crude oil-water mixture in both the presence and absence of gas are presented.
NASA Astrophysics Data System (ADS)
Lin, Xueliang; Ge, Xiaosong; Xu, Zhihong; Zheng, Zuci; Huang, Wei; Hong, Quanxing; Lin, Duo
2016-10-01
The early cancer detection is of great significance to increase the patient's survival rate and reduce the risk of cancer development. Surface enhanced Raman spectroscopy (SERS) technique, a rapid, convenient, nondestructive optical detection method, can provide a characteristic "fingerprint" information of target substances, even achieving single molecule detection. Its ultra-high detection sensitivity has made it become one of the most potential biochemical detection methods. Saliva, a multi-constituent oral fluid, contains the bio-markers which is capable of reflecting the systemic health condition of human, showing promising potential as an effect medium for disease monitoring. Compared with the serum samples, the collection and processing of saliva is safer, more convenient and noninvasive. Thus, saliva test is becoming the hotspot issues of the noninvasive cancer research field. This review highlights and analyzes current application progress within the field of SERS saliva test in cancer detection. Meanwhile, the primary research results of SERS saliva for the noninvasive differentiation of nasopharyngeal cancer, normal and rhinitis obtained by our group are shown.
Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Raboel, P. H.; Bartek, J.; Andresen, M.; Bellander, B. M.; Romner, B.
2012-01-01
Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement, optic nerve sheath diameter, CT scan/MRI and fundoscopy) can be used as reliable alternatives to the invasive techniques (ventriculostomy and microtransducers). Ventriculostomy is considered the gold standard in terms of accurate measurement of pressure, although microtransducers generally are just as accurate. Both invasive techniques are associated with a minor risk of complications such as hemorrhage and infection. Furthermore, zero drift is a problem with selected microtransducers. The non-invasive techniques are without the invasive methods' risk of complication, but fail to measure ICP accurately enough to be used as routine alternatives to invasive measurement. We conclude that invasive measurement is currently the only option for accurate measurement of ICP. PMID:22720148
Noninvasive estimation of assist pressure for direct mechanical ventricular actuation
NASA Astrophysics Data System (ADS)
An, Dawei; Yang, Ming; Gu, Xiaotong; Meng, Fan; Yang, Tianyue; Lin, Shujing
2018-02-01
Direct mechanical ventricular actuation is effective to reestablish the ventricular function with non-blood contact. Due to the energy loss within the driveline of the direct cardiac compression device, it is necessary to acquire the accurate value of assist pressure acting on the heart surface. To avoid myocardial trauma induced by invasive sensors, the noninvasive estimation method is developed and the experimental device is designed to measure the sample data for fitting the estimation models. By examining the goodness of fit numerically and graphically, the polynomial model presents the best behavior among the four alternative models. Meanwhile, to verify the effect of the noninvasive estimation, the simplified lumped parameter model is utilized to calculate the pre-support and the post-support left ventricular pressure. Furthermore, by adjusting the driving pressure beyond the range of the sample data, the assist pressure is estimated with the similar waveform and the post-support left ventricular pressure approaches the value of the adult healthy heart, indicating the good generalization ability of the noninvasive estimation method.
Driving working memory with frequency-tuned noninvasive brain stimulation.
Albouy, Philippe; Baillet, Sylvain; Zatorre, Robert J
2018-04-29
Frequency-tuned noninvasive brain stimulation is a recent approach in cognitive neuroscience that involves matching the frequency of transcranially applied electromagnetic fields to that of specific oscillatory components of the underlying neurophysiology. The objective of this method is to modulate ongoing/intrinsic brain oscillations, which correspond to rhythmic fluctuations of neural excitability, to causally change behavior. We review the impact of frequency-tuned noninvasive brain stimulation on the research field of human working memory. We argue that this is a powerful method to probe and understand the mechanisms of memory functions, targeting specifically task-related oscillatory dynamics, neuronal representations, and brain networks. We report the main behavioral and neurophysiological outcomes published to date, in particular, how functionally relevant oscillatory signatures in signal power and interregional connectivity yield causal changes of working memory abilities. We also present recent developments of the technique that aim to modulate cross-frequency coupling in polyrhythmic neural activity. Overall, the method has led to significant advances in our understanding of the mechanisms of systems neuroscience, and the role of brain oscillations in cognition and behavior. We also emphasize the translational impact of noninvasive brain stimulation techniques in the development of therapeutic approaches. © 2018 New York Academy of Sciences.
Report on Non-invasive acoustic monitoring of D2O concentration Oct 31 2017
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pantea, Cristian; Sinha, Dipen N.; Lakis, Rollin Evan
There is an urgent need for real-time monitoring of the hydrogen /deuterium ratio (H/D) for heavy water production monitoring. Based upon published literature, sound speed is sensitive to the deuterium content of heavy water and can be measured using existing acoustic methods to determine the deuterium concentration in heavy water solutions. We plan to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of quantifying H/D ratios in solution. A successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended H/D ratio measurements with a resolution of lessmore » than 0.2% vol.« less
Guissart, C; Dubucs, C; Raynal, C; Girardet, A; Tran Mau Them, F; Debant, V; Rouzier, C; Boureau-Wirth, A; Haquet, E; Puechberty, J; Bieth, E; Dupin Deguine, D; Khau Van Kien, P; Brechard, M P; Pritchard, V; Koenig, M; Claustres, M; Vincent, M C
2017-03-01
Analysis of cell-free foetal DNA (cff-DNA) in maternal plasma is very promising for early diagnosis of monogenic diseases; in particular, cystic fibrosis (CF). However, NIPD of single-gene disorders has been limited by the availability of suitable technical platforms and the need to set up patient or disease-specific custom-made approaches. To make research applications more readily accessible to the clinic, we offer a simple assay combining two independent methods to determine the presence or absence of paternally inherited foetal allele p.Phe508del (the most frequent mutation in CF patients worldwide). The first method detects the presence or absence of a p.Phe508del allele by Mutant Enrichment with 3'-Modified Oligonucleotide PCR coupled to Fragment Length Analysis (MEMO-PCR-FLA). The second method detects the p.Phe508del allele with classical Multiplex Fluorescent PCR including five intragenic and extragenic STR markers of the CFTR locus and a specific SRY sequence. We collected 24 plasma samples from 23 women carrying foetuses at risk for CF and tested each sample using both methods. Our new procedures were successfully applied to 10 couples where fathers carried the p.Phe508del mutation and mothers were carrying a different mutation in the CFTR gene. These simple tests provided clear positive or negative results from the maternal plasma of the pregnant women. We confirmed the presence of cff-DNA in the studied samples by the identification of a tri-allelic DNA profile using a miniSTR kit. All results were correlated with chorionic villus sampling or amniocentesis analyses. This NIPD approach, easily set up in any clinical laboratory where prenatal diagnosis is routinely performed, offers many advantages over current methods: it is simple, rapid, and cost-effective. It opens up the possibility for testing a large number of couples with offspring at risk for CF. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Development of Novel Noninvasive Methods of Stress Assessment in Baleen Whales
2015-09-30
large whales. Few methods exist for assessment of physiological stress levels of free-swimming cetaceans (Amaral 2010, ONR 2010, Hunt et al. 2013...adrenal hormone aldosterone . Our aim in this project is to further develop both techniques - respiratory hormone analysis and fecal hormone analysis...development of a noninvasive aldosterone assay (for both feces and blow) that can be used as an alternative measure of adrenal gland activation relative to
1986-03-01
radiations from the body in the infrared spectrum of light energy provides a passive, noninvasive method of measuring and recording a subject’s relative... a minimum during each test. In transmission radiography, dosage (or dose rate) is a measure of the * energy of the applied radiation . X-ray energy is... a function of frequency (E *hi) and is expressed in electron volts
A noninvasive, direct real-time PCR method for sex determination in multiple avian species
Brubaker, Jessica L.; Karouna-Renier, Natalie K.; Chen, Yu; Jenko, Kathryn; Sprague, Daniel T.; Henry, Paula F.P.
2011-01-01
Polymerase chain reaction (PCR)-based methods to determine the sex of birds are well established and have seen few modifications since they were first introduced in the 1990s. Although these methods allowed for sex determination in species that were previously difficult to analyse, they were not conducive to high-throughput analysis because of the laboriousness of DNA extraction and gel electrophoresis. We developed a high-throughput real-time PCR-based method for analysis of sex in birds, which uses noninvasive sample collection and avoids DNA extraction and gel electrophoresis.
Single Cell Spectroscopy: Noninvasive Measures of Small-Scale Structure and Function
Mousoulis, Charilaos; Xu, Xin; Reiter, David A.; Neu, Corey P.
2013-01-01
The advancement of spectroscopy methods attained through increases in sensitivity, and often with the coupling of complementary techniques, has enabled real-time structure and function measurements of single cells. The purpose of this review is to illustrate, in light of advances, the strengths and the weaknesses of these methods. Included also is an assessment of the impact of the experimental setup and conditions of each method on cellular function and integrity. A particular emphasis is placed on noninvasive and nondestructive techniques for achieving single cell detection, including nuclear magnetic resonance, in addition to physical, optical, and vibrational methods. PMID:23886910
A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient
Bettie, Nirmal Famila
2017-01-01
Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report. PMID:29284985
A Conservative Method of Retaining an Interim Obturator for a Total Maxillectomy Patient.
Bettie, Nirmal Famila
2017-11-01
Interim obturators are indicated during the postsurgical phases. It promotes surgical healing and serves as a temporary prosthesis to rehabilitate a patient with intra-oral surgical defect. Retention is gained by wiring, surgical suturing, and other noninvasive methods to enable functional rehabilitation and easy replacement with a permanent obturator. Interim obturators serve as an easy guide for replacing with definitive obturators by indicating prosthesis extensions and the required method of retention. A more conservative and noninvasive method of retaining an interim obturator for a maxillectomy patient is described in this case report.
Non-invasive imaging methods applied to neo- and paleontological cephalopod research
NASA Astrophysics Data System (ADS)
Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.
2013-11-01
Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum-maximum size of objects that can be studied, of the degree of post-processing needed and availability. Main application of the methods is seen in morphometry and volumetry of cephalopod shells in order to improve our understanding of diversity and disparity, functional morphology and biology of extinct and extant cephalopods.
Non-invasive toluene sensor for early diagnosis of lung cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saxena, Rahul; Srivastava, Sudha, E-mail: sudha.srivastava@jiit.ac.in
Here we present, quantification of volatile organic compounds in human breath for early detection of lung cancer to increase survival probability. Graphene oxide nanosheets synthesized by modified Hummer’s method were employed as a sensing element to detect the presence of toluene in the sample. Optical and morphological characterization of synthesized nanomaterial was performed by UV-Visible spectroscopy and scanning electron microscopy (SEM) respectively. Spectroscopic assay shows a linearly decreasing intensity of GO absorption peak with increasing toluene concentration with a linear range from 0-200 pM. While impedimetric sensor developed on a graphene oxide nanosheetsmodified screen printed electrodes displayed a decreasing electronmore » transfer resistance increasing toluene with much larger linear range of 0-1000 pM. Reported techniques are advantageous as these are simple, sensitive and cost effective, which can easily be extended for primary screening of other VOCs.« less
Appearance of acute gouty arthritis on indium-111-labeled leukocyte scintigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palestro, C.J.; Vega, A.; Kim, C.K.
1990-05-01
Indium-111-labeled leukocyte scintigraphy was performed on a 66-yr-old male with polyarticular acute gouty arthritis. Images revealed intense labeled leukocyte accumulation in a pattern indistinguishable from septic arthritis, in both knees and ankles, and the metatarsophalangeal joint of both great toes, all of which were involved in the acute gouty attack. Joint aspirate as well as blood cultures were reported as no growth; the patient was treated with intravenous colchicine and ACTH for 10 days with dramatic improvement noted. Labeled leukocyte imaging, repeated 12 days after the initial study, revealed near total resolution of joint abnormalities, concordant with the patient's clinicalmore » improvement. This case demonstrates that while acute gouty arthritis is a potential pitfall in labeled leukocyte imaging, in the presence of known gout, it may provide a simple, objective, noninvasive method of evaluating patient response to therapy.« less
Characterization of poly(vinyl acetate) based floating matrix tablets.
Strübing, Sandra; Metz, Hendrik; Mäder, Karsten
2008-03-03
Floating Kollidon SR matrix tablets containing Propranolol HCl were developed and characterized with respect to drug release characteristics and floating strength. Kollidon SR was able to delay Propranolol HCl release efficiently. Drug release kinetics was evaluated using the Korsmeyer-Peppas model and found to be governed by Fickian diffusion. Tablet floating started immediately and continued for 24 h. It was possible to monitor the floating strength of the matrix devices using a simple experimental setup. Floating strength was related to Kollidon SR level with improved floating characteristics for samples with a high polymer/drug ratio. Swelling characteristics of the tablets were analyzed by applying the equation according to Therien-Aubin et al. The influence of the polymer content on swelling characteristics was found to be only marginal. Furthermore, the new method of benchtop MRI was introduced to study the water diffusion and swelling behaviour non-invasively and continuously.
Few-femtosecond time-resolved measurements of X-ray free-electron lasers.
Behrens, C; Decker, F-J; Ding, Y; Dolgashev, V A; Frisch, J; Huang, Z; Krejcik, P; Loos, H; Lutman, A; Maxwell, T J; Turner, J; Wang, J; Wang, M-H; Welch, J; Wu, J
2014-04-30
X-ray free-electron lasers, with pulse durations ranging from a few to several hundred femtoseconds, are uniquely suited for studying atomic, molecular, chemical and biological systems. Characterizing the temporal profiles of these femtosecond X-ray pulses that vary from shot to shot is not only challenging but also important for data interpretation. Here we report the time-resolved measurements of X-ray free-electron lasers by using an X-band radiofrequency transverse deflector at the Linac Coherent Light Source. We demonstrate this method to be a simple, non-invasive technique with a large dynamic range for single-shot electron and X-ray temporal characterization. A resolution of less than 1 fs root mean square has been achieved for soft X-ray pulses. The lasing evolution along the undulator has been studied with the electron trapping being observed as the X-ray peak power approaches 100 GW.
Tung, Thanh Tran
2017-01-01
The early diagnosis of diseases, e.g., Parkinson’s and Alzheimer’s disease, diabetes, and various types of cancer, and monitoring the response of patients to the therapy plays a critical role in clinical treatment; therefore, there is an intensive research for the determination of many clinical analytes. In order to achieve point-of-care sensing in clinical practice, sensitive, selective, cost-effective, simple, reliable, and rapid analytical methods are required. Biosensors have become essential tools in biomarker sensing, in which electrode material and architecture play critical roles in achieving sensitive and stable detection. Carbon nanomaterials in the form of particle/dots, tube/wires, and sheets have recently become indispensable elements of biosensor platforms due to their excellent mechanical, electronic, and optical properties. This review summarizes developments in this lucrative field by presenting major biosensor types and variability of sensor platforms in biomedical applications. PMID:28825646
Automatic Detection of Blue-White Veil and Related Structures in Dermoscopy Images
Celebi, M. Emre; Iyatomi, Hitoshi; Stoecker, William V.; Moss, Randy H.; Rabinovitz, Harold S.; Argenziano, Giuseppe; Soyer, H. Peter
2011-01-01
Dermoscopy is a non-invasive skin imaging technique, which permits visualization of features of pigmented melanocytic neoplasms that are not discernable by examination with the naked eye. One of the most important features for the diagnosis of melanoma in dermoscopy images is the blue-white veil (irregular, structureless areas of confluent blue pigmentation with an overlying white “ground-glass” film). In this article, we present a machine learning approach to the detection of blue-white veil and related structures in dermoscopy images. The method involves contextual pixel classification using a decision tree classifier. The percentage of blue-white areas detected in a lesion combined with a simple shape descriptor yielded a sensitivity of 69.35% and a specificity of 89.97% on a set of 545 dermoscopy images. The sensitivity rises to 78.20% for detection of blue veil in those cases where it is a primary feature for melanoma recognition. PMID:18804955
Detection of bacterial growth by gas absorption.
Waters, J R
1992-05-01
When 24 different aerobic organisms were grown in a shaken culture, all were found to first absorb gas from the headspace. In a rudimentary medium, such as tryptic soy broth, 16 of the 24 organisms did not produce gas following the initial gas absorption. We have developed a simple, noninvasive method for detecting both gas absorption and production in multiple culture vials. The time to positivity was compared with that obtained by the BACTEC 460 blood culture system. For nearly all of these organisms, there was no difference. For some of those organisms that did not produce gas, e.g. Staphylococcus epidermidis, Moraxella osloensis, and Neisseria meningitidis, detection by gas absorption was a few hours faster. Gas absorption appears to be a promising technique for a new automated blood culture system because of its simplicity and because medium without special additives can be used to detect organisms that do not produce gas.
Surface studies of solids using integral x-ray-induced photoemission yield
Stoupin, Stanislav; Zhernenkov, Mikhail; Shi, Bing
2016-11-22
X-ray induced photoemission yield contains structural information complementary to that provided by X-ray Fresnel reflectivity, which presents an advantage to a wide variety of surface studies if this information is made easily accessible. Photoemission in materials research is commonly acknowledged as a method with a probing depth limited by the escape depth of the photoelectrons. Here we show that the integral hard-X-ray-induced photoemission yield is modulated by the Fresnel reflectivity of a multilayer structure and carries structural information that extends well beyond the photoelectron escape depth. A simple electric self-detection of the integral photoemission yield and Fourier data analysis permitmore » extraction of thicknesses of individual layers. The approach does not require detection of the reflected radiation and can be considered as a framework for non-invasive evaluation of buried layers with hard X-rays under grazing incidence.« less
Surface studies of solids using integral X-ray-induced photoemission yield
Stoupin, Stanislav; Zhernenkov, Mikhail; Shi, Bing
2016-01-01
X-ray induced photoemission yield contains structural information complementary to that provided by X-ray Fresnel reflectivity, which presents an advantage to a wide variety of surface studies if this information is made easily accessible. Photoemission in materials research is commonly acknowledged as a method with a probing depth limited by the escape depth of the photoelectrons. Here we show that the integral hard-X-ray-induced photoemission yield is modulated by the Fresnel reflectivity of a multilayer structure and carries structural information that extends well beyond the photoelectron escape depth. A simple electric self-detection of the integral photoemission yield and Fourier data analysis permit extraction of thicknesses of individual layers. The approach does not require detection of the reflected radiation and can be considered as a framework for non-invasive evaluation of buried layers with hard X-rays under grazing incidence. PMID:27874041
Safe paediatric intensive care. Part 1: Does more medical care lead to improved outcome?
Frey, Bernhard; Argent, Andrew
2004-06-01
Neonatal and paediatric intensive care has improved the prognosis for seriously sick infants and children. This has happened because of a pragmatic approach focused on stabilisation of vital functions and immense technological advances in diagnostic and therapeutic procedures. However, the belief that more medical care must inevitably lead to improved health is increasingly being questioned. This issue is especially relevant in developing countries where the introduction of highly specialised paediatric intensive care may not lead to an overall fall in child mortality. Even in developed countries, the complexity and availability of therapeutics and invasive procedures may put seriously ill children at additional risk. In both developing and industrialised countries the use of safe and simple procedures for appropriate periods, particular attention to drug prescription patterns and selection of appropriate aims and modes of therapy, including non-invasive methods, may minimise the risks of paediatric intensive care.
Hu, Chenghuan; Huang, Feizhou; Zhang, Rui; Zhu, Shaihong; Nie, Wanpin; Liu, Xunyang; Liu, Yinglong; Li, Peng
2015-01-01
Using optics combined with automatic control and computer real-time image detection technology, a novel noninvasive method of noncontact pressure manometry was developed based on the airflow and laser detection technology in this study. The new esophageal venous pressure measurement system was tested in-vitro experiments. A stable and adjustable pulse stream was produced from a self-developed pump and a laser emitting apparatus could generate optical signals which can be captured by image acquisition and analysis system program. A synchronization system simultaneous measured the changes of air pressure and the deformation of the vein wall to capture the vascular deformation while simultaneously record the current pressure value. The results of this study indicated that the pressure values tested by the new method have good correlation with the actual pressure value in animal experiments. The new method of noninvasive pressure measurement based on the airflow and laser detection technology is accurate, feasible, repeatable and has a good application prospects.
Feasibility of assessing [(18)F]FDG lung metabolism with late dynamic PET imaging.
Laffon, Eric; de Clermont, Henri; Vernejoux, Jean-Marc; Jougon, Jacques; Marthan, Roger
2011-04-01
The aim of this work was to non-invasively establish the feasibility of assessing 2-deoxy-2-[(18)F]fluoro-D-glucose ((18)F-FDG) lung metabolism with the use of a late dynamic positron emission tomograpy (PET) acquisition, i.e., beyond 2 h after injection. The present method has been probed in 11 patients without any respiratory disease, under fasting conditions, by assessing mean values of (18)F-FDG lung metabolism. A kinetic model analysis has been implemented on a simple calculation sheet. An arbitrary (population based) input function has been used in each individual, which was obtained from literature data. In the healthy lung, no (18)F-FDG release was found, and the mean values (±SD) of the (18)F-FDG uptake rate constant and of the fraction of the free tracer in blood and interstitial volume were: K = 0.0016 min(-1) (±0.0005), and F = 0.18 (±0.10), respectively. These results were in very close agreement with literature data that were obtained by both three-compartment model analysis and Patlak graphical analysis (gold standards), and that used an invasive blood sampling. Furthermore, K and the standard uptake value index have been compared. We conclude that assessing lung metabolism of (18)F-FDG in humans with the use of late dynamic PET imaging is feasible. The arbitrary input function of this non-invasive feasibility study could be replaced in further experiments by an input function obtained by arterial sampling. It is suggested that this method may prove useful to quantify (18)F-FDG lung metabolism under pathological conditions.
Scholz, A M; Bünger, L; Kongsro, J; Baulain, U; Mitchell, A D
2015-07-01
The ability to accurately measure body or carcass composition is important for performance testing, grading and finally selection or payment of meat-producing animals. Advances especially in non-invasive techniques are mainly based on the development of electronic and computer-driven methods in order to provide objective phenotypic data. The preference for a specific technique depends on the target animal species or carcass, combined with technical and practical aspects such as accuracy, reliability, cost, portability, speed, ease of use, safety and for in vivo measurements the need for fixation or sedation. The techniques rely on specific device-driven signals, which interact with tissues in the body or carcass at the atomic or molecular level, resulting in secondary or attenuated signals detected by the instruments and analyzed quantitatively. The electromagnetic signal produced by the instrument may originate from mechanical energy such as sound waves (ultrasound - US), 'photon' radiation (X-ray-computed tomography - CT, dual-energy X-ray absorptiometry - DXA) or radio frequency waves (magnetic resonance imaging - MRI). The signals detected by the corresponding instruments are processed to measure, for example, tissue depths, areas, volumes or distributions of fat, muscle (water, protein) and partly bone or bone mineral. Among the above techniques, CT is the most accurate one followed by MRI and DXA, whereas US can be used for all sizes of farm animal species even under field conditions. CT, MRI and US can provide volume data, whereas only DXA delivers immediate whole-body composition results without (2D) image manipulation. A combination of simple US and more expensive CT, MRI or DXA might be applied for farm animal selection programs in a stepwise approach.
Non-invasive Foetal ECG – a Comparable Alternative to the Doppler CTG?
Reinhard, J.; Louwen, F.
2012-01-01
This review discusses the alternative of using the non-invasive foetal ECG compared with the conventionally used Doppler CTG. Non-invasive abdominal electrocardiograms (ECG) have been approved for clinical routine since 2008; subsequently they were also approved for antepartum and subpartum procedures. The first study results have been published. Non-invasive foetal ECG is especially indicated during early pregnancy, while the Doppler CTG is recommended for the vernix period. Beyond the vernix period no difference has been recorded in the success rate of either approach. The foetal ECG signal quality is independent of the BMI, whereas the success rate of the Doppler CTG is diminished with an increased BMI. During the first stage of labour, non-invasive foetal ECG demonstrates better signal quality; however during the second stage of labour no difference has been identified between the methods. PMID:25308981
Soydan, Lydia C.; Kellihan, Heidi B.; Bates, Melissa L.; Stepien, Rebecca L.; Consigny, Daniel W.; Bellofiore, Alessandro; Francois, Christopher J.; Chesler, Naomi C.
2015-01-01
Objectives To compare noninvasive estimates of pulmonary artery pressure (PAP) obtained via echocardiography (ECHO) to invasive measurements of PAP obtained during right heart catheterization (RHC) across a wide range of PAP, to examine the accuracy of estimating right atrial pressure via ECHO (RAPECHO) compared to RAP measured by catheterization (RAPRHC), and to determine if adding RAPECHO improves the accuracy of noninvasive PAP estimations. Animals Fourteen healthy female beagle dogs. Methods ECHO and RHC performed at various data collection points, both at normal PAP and increased PAP (generated by microbead embolization). Results Noninvasive estimates of PAP were moderately but significantly correlated with invasive measurements of PAP. A high degree of variance was noted for all estimations, with increased variance at higher PAP. The addition of RAPECHO improved correlation and bias in all cases. RAPRHC was significantly correlated with RAPECHO and with subjectively assessed right atrial size (RA sizesubj). Conclusions Spectral Doppler assessments of tricuspid and pulmonic regurgitation are imperfect methods for predicting PAP as measured by catheterization despite an overall moderate correlation between invasive and noninvasive values. Noninvasive measurements may be better utilized as part of a comprehensive assessment of PAP in canine patients. RAPRHC appears best estimated based on subjective assessment of RA size. Including estimated RAPECHO in estimates of PAP improves the correlation and relatedness between noninvasive and invasive measures of PAP, but notable variability in accuracy of estimations persists. PMID:25601540
A non-invasive implementation of a mixed domain decomposition method for frictional contact problems
NASA Astrophysics Data System (ADS)
Oumaziz, Paul; Gosselet, Pierre; Boucard, Pierre-Alain; Guinard, Stéphane
2017-11-01
A non-invasive implementation of the Latin domain decomposition method for frictional contact problems is described. The formulation implies to deal with mixed (Robin) conditions on the faces of the subdomains, which is not a classical feature of commercial software. Therefore we propose a new implementation of the linear stage of the Latin method with a non-local search direction built as the stiffness of a layer of elements on the interfaces. This choice enables us to implement the method within the open source software Code_Aster, and to derive 2D and 3D examples with similar performance as the standard Latin method.
Zhao, Daoli; Wang, Tingting; Nahan, Keaton; Guo, Xuefei; Zhang, Zhanping; Dong, Zhongyun; Chen, Shuna; Chou, Da-Tren; Hong, Daeho; Kumta, Prashant N; Heineman, William R
2017-03-01
The effect of widely different corrosion rates of Mg alloys on four parameters of interest for in vivo characterization was evaluated: (1) the effectiveness of transdermal H 2 measurements with an electrochemical sensor for noninvasively monitoring biodegradation compared to the standard techniques of in vivo X-ray imaging and weight loss measurement of explanted samples, (2) the chemical compositions of the corrosion layers of the explanted samples by XPS, (3) the effect on animal organs by histology, and (4) the accumulation of corrosion by-products in multiple organs by ICP-MS. The in vivo biodegradation of three magnesium alloys chosen for their widely varying corrosion rates - ZJ41 (fast), WKX41 (intermediate) and AZ31 (slow) - were evaluated in a subcutaneous implant mouse model. Measuring H 2 with an electrochemical H 2 sensor is a simple and effective method to monitor the biodegradation process in vivo by sensing H 2 transdermally above magnesium alloys implanted subcutaneously in mice. The correlation of H 2 levels and biodegradation rate measured by weight loss shows that this non-invasive method is fast, reliable and accurate. Analysis of the insoluble biodegradation products on the explanted alloys by XPS showed all of them to consist primarily of Mg(OH) 2 , MgO, MgCO 3 and Mg 3 (PO 4 ) 2 with ZJ41 also having ZnO. The accumulation of magnesium and zinc were measured in 9 different organs by ICP-MS. Histological and ICP-MS studies reveal that there is no significant accumulation of magnesium in these organs for all three alloys; however, zinc accumulation in intestine, kidney and lung for the faster biodegrading alloy ZJ41 was observed. Although zinc accumulates in these three organs, no toxicity response was observed in the histological study. ICP-MS also shows higher levels of magnesium and zinc in the skull than in the other organs. Biodegradable devices based on magnesium and its alloys are promising because they gradually dissolve and thereby avoid the need for subsequent removal by surgery if complications arise. In vivo biodegradation rate is one of the crucial parameters for the development of these alloys. Promising alloys are first evaluated in vivo by being implanted subcutaneously in mice for 1month. Here, we evaluated several magnesium alloys with widely varying corrosion rates in vivo using multiple characterization techniques. Since the alloys biodegrade by reacting with water forming H 2 gas, we used a recently demonstrated, simple, fast and noninvasive method to monitor the biodegradation process by just pressing the tip of a H 2 sensor against the skin above the implant. The analysis of 9 organs (intestine, kidney, spleen, lung, heart, liver, skin, brain and skull) for accumulation of Mg and Zn revealed no significant accumulation of magnesium in these organs. Zinc accumulation in intestine, kidney and lung was observed for the faster corroding implant ZJ41. The surfaces of explanted alloys were analyzed to determine the composition of the insoluble biodegradation products. The results suggest that these tested alloys are potential candidates for biodegradable implant applications. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Noninvasive Evaluation of Special Alloys for Prostheses Using Complementary Methods
NASA Astrophysics Data System (ADS)
Savin, A.; Vizureanu, P.; Prevorovsky, Z.; Chlada, M.; Krofta, J.; Baltatu, M. S.; Istrate, B.; Steigmann, R.
2018-06-01
Ti-Mo-Si alloys have gained the attention of biomedical industry due to specific strength and corrosion resistance and the best biocompatibility among metallic materials used in medical prostheses. In order to characterize the material, the experimental determination of elastic matrix, mechanical wear and the probability of appearance and propagation of thin cracks are imposed. Thus, resonant ultrasound spectroscopy and acoustic emission as non-invasive methods and complementary methods as SEM, EDX are involved, to choose the best concentration of elements with the aim of mechanical properties improvement.
Electronic-nose devices - Potential for noninvasive early disease-detection applications
Alphus Dan Wilson
2017-01-01
Significant progress in the development of portable electronic devices is showing considerable promise to facilitate clinical diagnostic processes. The increasing global trend of shifts in healthcare policies and priorities toward shortening and improving the effectiveness of diagnostic procedures by utilizing non-invasive methods should provide multiple benefits of...
Non-invasive Prediction of Pork Loin Tenderness
USDA-ARS?s Scientific Manuscript database
The present experiment was conducted to develop a non-invasive method to predict tenderness of pork loins. Boneless pork loins (n = 901) were evaluated either on line on the loin boning and trimming line of large-scale commercial plants (n = 465) or at the U.S. Meat Animal Research Center abattoir ...
Informative priors on fetal fraction increase power of the noninvasive prenatal screen
USDA-ARS?s Scientific Manuscript database
Noninvasive prenatal screening (NIPS) sequences a mixture of the maternal and fetal cell-free DNA. Fetal trisomy can be detected by examining chromosomal dosages estimated from sequencing reads. The traditional method uses the Z-test, which compares a subject against a set of euploid controls, where...
Vyas, Kaetan J; Danz, David; Gilman, Robert H; Wise, Robert A; León-Velarde, Fabiola; Miranda, J Jaime; Checkley, William
2015-06-01
Vyas, Kaetan J., David Danz, Robert H. Gilman, Robert A. Wise, Fabiola León-Velarde, J. Jaime Miranda, and William Checkley. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt Med Biol 16:162-168, 2015.--Globally, over 140 million people are at risk of developing chronic mountain sickness, a common maladaptation to life at high altitude (>2500 meters above sea level). The diagnosis is contingent upon the identification of excessive erythrocytosis (EE). Current best practices to identify EE require a venous blood draw, which is cumbersome for large-scale surveillance. We evaluated two point-of-care biomarkers to screen for EE: noninvasive spot-check tests of total hemoglobin and oxyhemoglobin saturation (Pronto-7, Masimo Corporation). We conducted paired evaluations of total serum hemoglobin from a venous blood draw and noninvasive, spot-check testing of total hemoglobin and oxyhemoglobin saturation with the Pronto-7 in 382 adults aged ≥35 years living in Puno, Peru (3825 meters above sea level). We used the Bland-Altman method to measure agreement between the noninvasive hemoglobin assessment and the gold standard lab hemoglobin analyzer. Mean age was 58.8 years and 47% were male. The Pronto-7 test was unsuccessful in 21 (5%) participants. Limits of agreement between total hemoglobin measured via venous blood draw and the noninvasive, spot-check test ranged from -2.8 g/dL (95% CI -3.0 to -2.5) to 2.5 g/dL (95% CI 2.2 to 2.7), with a bias of -0.2 g/dL (95% CI -0.3 to -0.02) for the difference between total hemoglobin and noninvasive hemoglobin concentrations. Overall, the noninvasive spot-check test of total hemoglobin had a better area under the receiver operating characteristic curve compared to oxyhemoglobin saturation for the identification of EE as measured by a gold standard laboratory hemoglobin analyzer (0.96 vs. 0.82; p<0.001). Best cut-off values to screen for EE with the Pronto 7 were ≥19.9 g/dL in males and ≥17.5 g/dL in females. At these cut-points, sensitivity and specificity were both 92% and 89% for males and females, respectively. A noninvasive, spot-check test of total hemoglobin had low bias and high discrimination for the detection of EE in high altitude Peru, and may be a useful point-of-care tool for large-scale surveillance in high-altitude settings.
NASA Astrophysics Data System (ADS)
Fajkus, Marcel; Nedoma, Jan; Martinek, Radek; Vasinek, Vladimir
2017-10-01
In this article, we describe an innovative non-invasive method of Fetal Phonocardiography (fPCG) using fiber-optic sensors and adaptive algorithm for the measurement of fetal heart rate (fHR). Conventional PCG is based on a noninvasive scanning of acoustic signals by means of a microphone placed on the thorax. As for fPCG, the microphone is placed on the maternal abdomen. Our solution is based on patent pending non-invasive scanning of acoustic signals by means of a fiber-optic interferometer. Fiber-optic sensors are resistant to technical artifacts such as electromagnetic interferences (EMI), thus they can be used in situations where it is impossible to use conventional EFM methods, e.g. during Magnetic Resonance Imaging (MRI) examination or in case of delivery in water. The adaptive evaluation system is based on Recursive least squares (RLS) algorithm. Based on real measurements provided on five volunteers with their written consent, we created a simplified dynamic signal model of a distribution of heartbeat sounds (HS) through the human body. Our created model allows us to verification of the proposed adaptive system RLS algorithm. The functionality of the proposed non-invasive adaptive system was verified by objective parameters such as Sensitivity (S+) and Signal to Noise Ratio (SNR).
NASA Astrophysics Data System (ADS)
Feng, Ximeng; Li, Gang; Yu, Haixia; Wang, Shaohui; Yi, Xiaoqing; Lin, Ling
2018-03-01
Noninvasive blood component analysis by spectroscopy has been a hotspot in biomedical engineering in recent years. Dynamic spectrum provides an excellent idea for noninvasive blood component measurement, but studies have been limited to the application of broadband light sources and high-resolution spectroscopy instruments. In order to remove redundant information, a more effective wavelength selection method has been presented in this paper. In contrast to many common wavelength selection methods, this method is based on sensing mechanism which has a clear mechanism and can effectively avoid the noise from acquisition system. The spectral difference coefficient was theoretically proved to have a guiding significance for wavelength selection. After theoretical analysis, the multi-band spectral difference coefficient-wavelength selection method combining with the dynamic spectrum was proposed. An experimental analysis based on clinical trial data from 200 volunteers has been conducted to illustrate the effectiveness of this method. The extreme learning machine was used to develop the calibration models between the dynamic spectrum data and hemoglobin concentration. The experiment result shows that the prediction precision of hemoglobin concentration using multi-band spectral difference coefficient-wavelength selection method is higher compared with other methods.
Umemura, Takeji; Joshita, Satoru; Sekiguchi, Tomohiro; Usami, Yoko; Shibata, Soichiro; Kimura, Takefumi; Komatsu, Michiharu; Matsumoto, Akihiro; Ota, Masao; Tanaka, Eiji
2015-06-01
Noninvasive markers of liver fibrosis in patients with primary biliary cirrhosis (PBC) are needed for predicting disease progression. As the Wisteria floribunda agglutinin-positive Mac-2-binding protein (WFA(+)-M2BP) was recently established as a liver fibrosis glycobiomarker in chronic hepatitis C, we assessed its efficacy in evaluating liver fibrosis stage and disease progression in PBC. A total of 137 patients with PBC who underwent liver biopsy and serological tests for WFA(+)-M2BP were enrolled. All patients were treated with ursodeoxycholic acid. Clinical data were compared with those for other noninvasive markers (aspartate aminotransferase-to-platelet ratio, FIB-4 index, aspartate aminotransferase/alanine aminotransferase ratio, Forn's index, and Mayo score) for estimating liver fibrosis using receiver operating characteristic analysis. The association between WFA(+)-M2BP and clinical outcome (liver decompensation, liver transplantation, or death) was evaluated using the Cox proportional hazards model with stepwise method. WFA(+)-M2BP was independently associated with liver fibrosis stage as determined by liver biopsy. The cutoff values of WFA(+)-M2BP for fibrosis stages ≥F1, ≥F2, ≥F3, and F4 were 0.7, 1.0, 1.4, and 2.0, respectively. The area under the receiver operating characteristic curve values for significant fibrosis, severe fibrosis, and cirrhosis were 0.979, 0.933, and 0.965, respectively. WFA(+)-M2BP was significantly superior to the other indices for the determination of significant and severe fibrosis stages. Furthermore, the WFA(+)-M2BP level at enrollment was strongly and independently associated with clinical outcome (hazard ratio 18.59, P=0.021). Baseline measurements of WFA(+)-M2BP represent a simple and reliable noninvasive surrogate marker of liver fibrosis and prognosis in patients with PBC.
Fantini, Sergio; Sassaroli, Angelo; Tgavalekos, Kristen T.; Kornbluth, Joshua
2016-01-01
Abstract. Cerebral blood flow (CBF) and cerebral autoregulation (CA) are critically important to maintain proper brain perfusion and supply the brain with the necessary oxygen and energy substrates. Adequate brain perfusion is required to support normal brain function, to achieve successful aging, and to navigate acute and chronic medical conditions. We review the general principles of CBF measurements and the current techniques to measure CBF based on direct intravascular measurements, nuclear medicine, X-ray imaging, magnetic resonance imaging, ultrasound techniques, thermal diffusion, and optical methods. We also review techniques for arterial blood pressure measurements as well as theoretical and experimental methods for the assessment of CA, including recent approaches based on optical techniques. The assessment of cerebral perfusion in the clinical practice is also presented. The comprehensive description of principles, methods, and clinical requirements of CBF and CA measurements highlights the potentially important role that noninvasive optical methods can play in the assessment of neurovascular health. In fact, optical techniques have the ability to provide a noninvasive, quantitative, and continuous monitor of CBF and autoregulation. PMID:27403447
Point of care hemoglobin testing in plateletpheresis donors: Noninvasive versus invasive methods.
Mallhi, R S; Pawar, Amit; Kushwaha, Neerja; Kumar, Sudeep; Dimri, Ujjwal
2016-10-01
Predonation hemoglobin (Hb) for plateletpheresis donors is estimated by presently available invasive methods. Venous samples of only those donors whose Hb is more than 12.5 g/dl are screened for complete blood count and transfusion transmissible infections. There is a pressing need to substitute this invasive Hb test with noninvasive one to reduce donor discomfort and avoid further pricking the donor. We therefore went ahead with the aim of comparing a noninvasive Hb estimation method NBM 200 with the invasive method - Hemocue, taking SYSMEX KX-21 as a gold standard. 500 voluntary consenting plateletpheresis donors qualifying the laid down criteria for platelet donation were included in the study. Hb readings obtained by the NBM 200 and Hemocue were compared to those obtained from the fully automated hematology analyzer SYSMEX KX-21. Coefficients of correlation were found to be statistically significant at <0.0001 level of confidence. Results of Friedman's test on the three methods also showed significant difference in means. Bland-Altman plots and mountain plots also confirm the same. NBM 200 was found to be more sensitive, specific, and precise than Hemocue in detecting ineligible donors. NBM 200 was found to be more sensitive, specific, and precise as compared to Hemocue for predonation screening of Hb in plateletpheresis donors and the prime benefit it offers is that it is 'noninvasive' thereby assisting in stemming the platelet donor pool. The onus lies on the blood transfusion services to make use of appropriately validated gadgets that reduce the donor discomfort.
Non-invasive neural stimulation
NASA Astrophysics Data System (ADS)
Tyler, William J.; Sanguinetti, Joseph L.; Fini, Maria; Hool, Nicholas
2017-05-01
Neurotechnologies for non-invasively interfacing with neural circuits have been evolving from those capable of sensing neural activity to those capable of restoring and enhancing human brain function. Generally referred to as non-invasive neural stimulation (NINS) methods, these neuromodulation approaches rely on electrical, magnetic, photonic, and acoustic or ultrasonic energy to influence nervous system activity, brain function, and behavior. Evidence that has been surmounting for decades shows that advanced neural engineering of NINS technologies will indeed transform the way humans treat diseases, interact with information, communicate, and learn. The physics underlying the ability of various NINS methods to modulate nervous system activity can be quite different from one another depending on the energy modality used as we briefly discuss. For members of commercial and defense industry sectors that have not traditionally engaged in neuroscience research and development, the science, engineering and technology required to advance NINS methods beyond the state-of-the-art presents tremendous opportunities. Within the past few years alone there have been large increases in global investments made by federal agencies, foundations, private investors and multinational corporations to develop advanced applications of NINS technologies. Driven by these efforts NINS methods and devices have recently been introduced to mass markets via the consumer electronics industry. Further, NINS continues to be explored in a growing number of defense applications focused on enhancing human dimensions. The present paper provides a brief introduction to the field of non-invasive neural stimulation by highlighting some of the more common methods in use or under current development today.
Noninvasive Methods for Determining Lesion Depth from Vesicant Exposure
2007-01-01
LDPI. Chilcott et al19 used several noninvasive bio- a bolus through a central or peripheral venous line. engineering methods to monitor wound healing...ade- bolus through a central or peripheral venous line. The quate NBF into the tissue, two parallel cuts approxi- first two range finding pigs were...not more than 5.0%), its use creasing the size of the scan area, and/or decreasing is contraindicated in patients with a history of allergy the number
A new CFD based non-invasive method for functional diagnosis of coronary stenosis.
Xie, Xinzhou; Zheng, Minwen; Wen, Didi; Li, Yabing; Xie, Songyun
2018-03-22
Accurate functional diagnosis of coronary stenosis is vital for decision making in coronary revascularization. With recent advances in computational fluid dynamics (CFD), fractional flow reserve (FFR) can be derived non-invasively from coronary computed tomography angiography images (FFR CT ) for functional measurement of stenosis. However, the accuracy of FFR CT is limited due to the approximate modeling approach of maximal hyperemia conditions. To overcome this problem, a new CFD based non-invasive method is proposed. Instead of modeling maximal hyperemia condition, a series of boundary conditions are specified and those simulated results are combined to provide a pressure-flow curve for a stenosis. Then, functional diagnosis of stenosis is assessed based on parameters derived from the obtained pressure-flow curve. The proposed method is applied to both idealized and patient-specific models, and validated with invasive FFR in six patients. Results show that additional hemodynamic information about the flow resistances of a stenosis is provided, which cannot be directly obtained from anatomy information. Parameters derived from the simulated pressure-flow curve show a linear and significant correlations with invasive FFR (r > 0.95, P < 0.05). The proposed method can assess flow resistances by the pressure-flow curve derived parameters without modeling of maximal hyperemia condition, which is a new promising approach for non-invasive functional assessment of coronary stenosis.
User-friendly freehand ultrasound calibration using Lego bricks and automatic registration.
Xiao, Yiming; Yan, Charles Xiao Bo; Drouin, Simon; De Nigris, Dante; Kochanowska, Anna; Collins, D Louis
2016-09-01
As an inexpensive, noninvasive, and portable clinical imaging modality, ultrasound (US) has been widely employed in many interventional procedures for monitoring potential tissue deformation, surgical tool placement, and locating surgical targets. The application requires the spatial mapping between 2D US images and 3D coordinates of the patient. Although positions of the devices (i.e., ultrasound transducer) and the patient can be easily recorded by a motion tracking system, the spatial relationship between the US image and the tracker attached to the US transducer needs to be estimated through an US calibration procedure. Previously, various calibration techniques have been proposed, where a spatial transformation is computed to match the coordinates of corresponding features in a physical phantom and those seen in the US scans. However, most of these methods are difficult to use for novel users. We proposed an ultrasound calibration method by constructing a phantom from simple Lego bricks and applying an automated multi-slice 2D-3D registration scheme without volumetric reconstruction. The method was validated for its calibration accuracy and reproducibility. Our method yields a calibration accuracy of [Formula: see text] mm and a calibration reproducibility of 1.29 mm. We have proposed a robust, inexpensive, and easy-to-use ultrasound calibration method.
NASA Astrophysics Data System (ADS)
Mycek, Mary-Ann; Urayama, Paul; Zhong, Wei; Sloboda, Roger D.; Dragnev, Konstantin H.; Dmitrovsky, Ethan
2003-10-01
Tissue fluorescence spectroscopy and imaging are being investigated as potential methods for non-invasive detection of pre-neoplastic change in the lung and other organ systems. A substantial contribution to tissue fluorescence is known to arise from endogenous cellular fluorophores. Using steady-state and time-resolved fluorescence spectroscopy and imaging, we characterized the endogenous fluorescence properties of immortalized and carcinogen-transformed human bronchial epithelial cells. Non-invasive sensing of endogenous molecular biomarkers associated with human bronchial pre-neoplasia will be discussed.
Valdes, Claudia P.; Varma, Hari M.; Kristoffersen, Anna K.; Dragojevic, Tanja; Culver, Joseph P.; Durduran, Turgut
2014-01-01
We introduce a new, non-invasive, diffuse optical technique, speckle contrast optical spectroscopy (SCOS), for probing deep tissue blood flow using the statistical properties of laser speckle contrast and the photon diffusion model for a point source. The feasibility of the method is tested using liquid phantoms which demonstrate that SCOS is capable of measuring the dynamic properties of turbid media non-invasively. We further present an in vivo measurement in a human forearm muscle using SCOS in two modalities: one with the dependence of the speckle contrast on the source-detector separation and another on the exposure time. In doing so, we also introduce crucial corrections to the speckle contrast that account for the variance of the shot and sensor dark noises. PMID:25136500
A technology roadmap of smart biosensors from conventional glucose monitoring systems.
Shende, Pravin; Sahu, Pratiksha; Gaud, Ram
2017-06-01
The objective of this review article is to focus on technology roadmap of smart biosensors from a conventional glucose monitoring system. The estimation of glucose with commercially available devices involves analysis of blood samples that are obtained by pricking finger or extracting blood from the forearm. Since pain and discomfort are associated with invasive methods, the non-invasive measurement techniques have been investigated. The non-invasive methods show advantages like non-exposure to sharp objects such as needles and syringes, due to which there is an increase in testing frequency, improved control of glucose concentration and absence of pain and biohazard materials. This review study is aimed to describe recent invasive techniques and major noninvasive techniques, viz. biosensors, optical techniques and sensor-embedded contact lenses for glucose estimation.
Spectral-spatial classification for noninvasive cancer detection using hyperspectral imaging
NASA Astrophysics Data System (ADS)
Lu, Guolan; Halig, Luma; Wang, Dongsheng; Qin, Xulei; Chen, Zhuo Georgia; Fei, Baowei
2014-10-01
Early detection of malignant lesions could improve both survival and quality of life of cancer patients. Hyperspectral imaging (HSI) has emerged as a powerful tool for noninvasive cancer detection and diagnosis, with the advantage of avoiding tissue biopsy and providing diagnostic signatures without the need of a contrast agent in real time. We developed a spectral-spatial classification method to distinguish cancer from normal tissue on hyperspectral images. We acquire hyperspectral reflectance images from 450 to 900 nm with a 2-nm increment from tumor-bearing mice. In our animal experiments, the HSI and classification method achieved a sensitivity of 93.7% and a specificity of 91.3%. The preliminary study demonstrated that HSI has the potential to be applied in vivo for noninvasive detection of tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levitskaia, Tatiana G.; Bryan, Samuel A.; Creim, Jeffrey A.
2012-08-01
In the event of an intentional or accidental release of ionizing radiation in a densely populated area, timely assessment and triage of the general population for the radiation exposure is critical. In particular, a significant number of the victims may sustain cutaneous radiation injury, which increases the mortality and worsens the overall prognosis of the victims suffered from combined thermal/mechanical and radiation trauma. Diagnosis of the cutaneous radiation injury is challenging, and established methods largely rely on visual manifestations, presence of the skin contamination, and a high degree of recall by the victim. Availability of a high throughput non-invasive inmore » vivo biodosimetry tool for assessment of the radiation exposure of the skin is of particular importance for the timely diagnosis of the cutaneous injury. In the reported investigation, we have tested the potential of an optical reflectance spectroscopy for the evaluation of the radiation injury to the skin. This is technically attractive because optical spectroscopy relies on well-established and routinely used for various applications instrumentation, one example being pulse oximetry which uses selected wavelengths for the quantification of the blood oxygenation. Our method relies on a broad spectral region ranging from the locally absorbed, shallow-penetrating ultraviolet and visible (250 to 800 nm) to more deeply penetrating near-Infrared (800 – 1600 nm) light for the monitoring of multiple physiological changes in the skin upon irradiation. Chemometrics is a multivariate methodology that allows the information from entire spectral region to be used to generate predictive regression models. In this report we demonstrate that simple spectroscopic method, such as the optical reflectance spectroscopy, in combination with multivariate data analysis, offers the promise of rapid and non-invasive in vivo diagnosis and monitoring of the cutaneous radiation exposure, and is able accurately predict the dose and time of exposure in the rodent model.« less
NASA Astrophysics Data System (ADS)
Freitag, B.; Sroka, R.; Koelle, S.; Becker, A. J.; Khoder, W.; Pongratz, T.; Stief, C. G.; Trottmann, M.
2014-03-01
Introduction and objective: Vasectomy is a well-established method in family control. Even though it is a safe and low risk operation, this surgery is invasive and difficult to reverse. Therefore the aim of this study was to investigate new non-invasive methods for occlusion of the seminal duct. Material and Methods: Seminal duct tissue was obtained from patients (n=30) suffering from prostate cancer and therefore undergoing prostatectomy. In a first set of experiments, the seminal duct was occluded by intraluminal application of Histoacryl® (Braun Aesculap AG, Tuttlingen, Germany). In a 2nd set of experiments, endoluminal laser induced occlusion was performed. Four different laser wavelengths (1940nm, 1470nm, 1064nm, 940nm) and different sets of laser parameters (e.g. power, exposure duration, fibre diameter, energy applied) were compared. Effectiveness of occlusion of the seminal duct was proven by post-treatment irrigation flow measurement, as well as by morphological analyses. To evaluate a potential damage of the surrounding tissue, external temperature was measured using a thermometer during laser application. Results: Intraluminal application of Histoacryl® induced an immediate and complete occlusion of the seminal duct. The underlying connective tissue maintained its functional integrity after this treatment. By laser light application to a Histoacryl® block, a hole could be created into the block thus indicating the possibility of recanalization. Treatment with laser energy resulted in shrinkage of the ductal lumen. The laser application generally caused necrosis in the epithelium and induced formation of vacuoles in the underlying connective tissue. As described for endoluminal varicose treatment, this distinct local reaction might result in an intense inflammation leading to a functional occlusion of the vas deferens. Conclusions: Both laser-induced occlusion and application of Histoacryl® are fast and simple techniques which may be able to achieve a functional occlusion of the seminal duct. The application of Histoacryl® additionally may be easily reversible by laser treatment.
Selective digestion of Ba2+/Ca2+ alginate gel microdroplets for single-cell handling
NASA Astrophysics Data System (ADS)
Odaka, Masao; Hattori, Akihiro; Matsuura, Kenji; Yasuda, Kenji
2018-06-01
Cells encapsuled by polymer microdroplets are an effective platform for the identification and separation of individual cells for single-cell-based analysis. However, a key challenge is to maintain and release the captured cells in the microdroplets selectively, nondestructively, and noninvasively. We developed a simple method of encapsulating cells in alginate microdroplets having different digestion characteristics. Cells were diluted with an alginate polymer of sol state and encapsulated into microdroplets with Ba2+ and Ca2+ by a spray method. When a chelating buffer was applied, alginate gel microdroplets were digested according to the difference in chelating efficiency of linkage-divalent cations; hence, two types of alginate microdroplets were formed. Moreover, we examined the capability of the alginate gel to exchange linkage-divalent cations and found that both Ca2+ exchange in Ba-alginate microdroplets and Ba2+ exchange in Ca-alginate microdroplets occurred. These results indicate that the potential applications of a mixture of alginate microdroplets with different divalent cations control the selective digestion of microdroplets to improve the high-throughput, high-content microdroplet-based separation, analysis, or storage of single cells.
Detecting occlusion inside a ventricular catheter using photoacoustic imaging through skull
NASA Astrophysics Data System (ADS)
Tavakoli, Behnoosh; Guo, Xiaoyu; Taylor, Russell H.; Kang, Jin U.; Boctor, Emad M.
2014-03-01
Ventricular catheters are used to treat hydrocephalus by diverting the excess of the cerebrospinal fluid (CSF) to the reabsorption site so as to regulate the intracranial pressure. The failure rate of these shunts is extremely high due to the ingrown tissue that blocks the CSF flow. We have studied a method to image the occlusion inside the shunt through the skull. In this approach the pulsed laser light coupled to the optical fiber illuminate the occluding tissue inside the catheter and an external ultrasound transducer is applied to detect the generated photoacoustic signal. The feasibility of this method is investigated using a phantom made of ovis aries brain tissue and adult human skull. We were able to image the target inside the shunt located 20mm deep inside the brain through about 4mm thick skull bone. This study could lead to the development of a simple, safe and non-invasive device for percutaneous restoration of patency to occluded shunts. This will eliminate the need of the surgical replacement of the occluded catheters which expose the patients to risks including hemorrhage and brain injury.
Size-amplified acoustofluidic separation of circulating tumor cells with removable microbeads
NASA Astrophysics Data System (ADS)
Liu, Huiqin; Ao, Zheng; Cai, Bo; Shu, Xi; Chen, Keke; Rao, Lang; Luo, Changliang; Wang, Fu-Bin; Liu, Wei; Bondesson, Maria; Guo, Shishang; Guo, Feng
2018-06-01
Isolation and analysis of rare circulating tumor cells (CTCs) is of great interest in cancer diagnosis, prognosis, and treatment efficacy evaluation. Acoustofluidic cell separation becomes an attractive method due to its contactless, noninvasive, simple, and versatile features. However, the indistinctive physical difference between CTCs and normal blood cells limits the purity of CTCs using current acoustic methods. Herein, we demonstrate a size-amplified acoustic separation and release of CTCs with removable microbeads. CTCs selectively bound to size-amplifiers (40 μm-diameter anti-EpCAM/gelatin-coated SiO2 microbeads) have significant physical differences (size and mechanics) compared to normal blood cells, resulting in an amplification of acoustic radiation force approximately a hundredfold over that of bare CTCs or normal blood cells. Therefore, CTCs can be efficiently sorted out with size-amplifiers in a traveling surface acoustic wave microfluidic device and released from size-amplifiers by enzymatic degradation for further purification or downstream analysis. We demonstrate a cell separation from blood samples with a total efficiency (E total) of ∼ 77%, purity (P) of ∼ 96%, and viability (V) of ∼83% after releasing cells from size-amplifiers. Our method substantially improves the emerging application of rare cell purification for translational medicine.
Messerli, Mark A.; Collis, Leon P.; Smith, Peter J.S.
2009-01-01
Previously, functional mapping of channels has been achieved by measuring the passage of net charge and of specific ions with electrophysiological and intracellular fluorescence imaging techniques. However, functional mapping of ion channels using extracellular ion-selective microelectrodes has distinct advantages over the former methods. We have developed this method through measurement of extracellular K+ gradients caused by efflux through Ca2+-activated K+ channels expressed in Chinese hamster ovary cells. We report that electrodes constructed with short columns of a mechanically stable K+-selective liquid membrane respond quickly and measure changes in local [K+] consistent with a diffusion model. When used in close proximity to the plasma membrane (<4 μm), the ISMs pose a barrier to simple diffusion, creating an ion trap. The ion trap amplifies the local change in [K+] without dramatically changing the rise or fall time of the [K+] profile. Measurement of extracellular K+ gradients from activated rSlo channels shows that rapid events, 10–55 ms, can be characterized. This method provides a noninvasive means for functional mapping of channel location and density as well as for characterizing the properties of ion channels in the plasma membrane. PMID:19217875
Chen, Lung-Chi; Lippmann, Morton
2015-01-01
In this review, we outline the need for laboratory-based inhalation toxicology studies, the historical background on adverse health effects of airborne toxicants, and the benefits of advance planning for the building of analytic options into the study design to maximize the scientific gains to be derived from the investments in the study. We then discuss methods for: 1) the generation and characterization of exposure atmospheres for inhalation exposures in humans and laboratory animals; 2) their delivery and distribution into and within whole-body exposure chambers, head-only exposure chambers, face-masks, and mouthpieces or nasal catheters; 3) options for on-line functional assays during and between exposures; and 4) options for serial non-invasive assays of response. In doing so, we go beyond exposures to single agents and simple mixtures, and include methods for evaluating biological responses to complex environmental mixtures. We also emphasize that great care should be taken in the design and execution of such studies so that the scientific returns can be maximized both initially, and in follow-up utilization of archived samples of the exposure atmospheres, excreta, and tissues collected for histology. PMID:25645246
Sader, John E; Lu, Jianing; Mulvaney, Paul
2014-11-01
Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, whose shapes vary considerably, and experimentally verify these results. The dynamic-to-static optical lever sensitivity ratio is found to range from 1.09 to 1.41 for the cantilevers studied - in stark contrast to the constant value of 1.09 used widely in current calibration studies. This analysis shows that accuracy of the thermal noise method for the static spring constant is strongly dependent on cantilever geometry - neglect of these dynamic-to-static factors can induce errors exceeding 100%. We also discuss a simple experimental approach to non-invasively and simultaneously determine the dynamic and static spring constants and optical lever sensitivities of cantilevers of arbitrary shape, which is applicable to all AFM platforms that have the thermal noise method for spring constant calibration.
Non-Invasive Acoustic-Based Monitoring of Heavy Water and Uranium Process Solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pantea, Cristian; Sinha, Dipen N.; Lakis, Rollin Evan
2017-11-02
The goals of the project are to leverage laboratory scientific strength in physical acoustics for critical international safeguards applications; create hardware demonstration capability for noninvasive, near real time, and low cost process monitor to capture future technology development programs; and measure physical property data to support method applicability.
Differential radioactivity monitor for non-invasive detection of ocular melanoma
Lambrecht, R.M.; Packer, S.
1982-09-23
There is described an apparatus and method for diagnosing ocular cancer that is both non-invasive and accurate which comprises two radiation detectors positioned before each of the patient's eyes which will measure the radiation level produced in each eye after the administration of a tumor-localizing radiopharmaceutical such as gallium-67.
Georgsson, Susanne; Sahlin, Ellika; Iwarsson, Moa; Nordenskjöld, Magnus; Gustavsson, Peter; Iwarsson, Erik
2017-06-01
Non-invasive prenatal testing (NIPT) was recently introduced for prenatal testing of genetic disorders. Cell-free fetal DNA is present in maternal blood during pregnancy and enables detection of fetal chromosome aberrations in a maternal blood sample. The public perspective to this new, simple method has not been illuminated. The views of young people (i.e. future parents) are important to develop suitable counseling strategies regarding prenatal testing. The aim was to explore Swedish high school students' attitudes, knowledge and preferences regarding NIPT. A questionnaire was completed by 305 students recruited from one high school in Stockholm, November and December 2014. Most students (80 %) considered prenatal testing as good. The majority (65 %) was positive or very positive towards NIPT and 62 % stated that they potentially would like to undergo the test if they or their partner was pregnant. The vast majority (94 %) requested further information about NIPT. Most students (61 %) preferred verbal information, whereas 20 % preferred information via the Internet. The majority of the high school students was positive towards prenatal testing and most was positive towards NIPT. Further, information was requested by the vast majority before making a decision about NIPT. Most of the students preferred verbal information and to a lesser extent information via the Internet. The attitudes, knowledge and preferences for risk information concerning NIPT in young adults are important, in order to increase knowledge on how to educate and inform future parents.
Ultrasonographic Assessment of Diaphragm Function in Critically Ill Subjects.
Umbrello, Michele; Formenti, Paolo
2016-04-01
The majority of patients admitted to the ICU require mechanical ventilation as a part of their process of care. However, mechanical ventilation itself or the underlying disease can lead to dysfunction of the diaphragm, a condition that may contribute to the failure of weaning from mechanical ventilation. However, extended time on the ventilator increases health-care costs and greatly increases patient morbidity and mortality. Nevertheless, symptoms and signs of muscle disease in a bedridden (or bed rest-only) ICU patient are often difficult to assess because of concomitant confounding factors. Conventional assessment of diaphragm function lacks specific, noninvasive, time-saving, and easily performed bedside tools or requires patient cooperation. Recently, the use of ultrasound has raised great interest as a simple, noninvasive method of quantification of diaphragm contractile activity. In this review, we discuss the physiology and the relevant pathophysiology of diaphragm function, and we summarize the recent findings concerning the evaluation of its (dys)function in critically ill patients, with a special focus on the role of ultrasounds. We describe how to assess diaphragm excursion and diaphragm thickening during breathing and the meaning of these measurements under spontaneous or mechanical ventilation as well as the reference values in health and disease. The spread of ultrasonographic assessment of diaphragm function may possibly result in timely identification of patients with diaphragm dysfunction and to a potential improvement in the assessment of recovery from diaphragm weakness. Copyright © 2016 by Daedalus Enterprises.
A review of novel optical imaging strategies of the stroke pathology and stem cell therapy in stroke
Aswendt, Markus; Adamczak, Joanna; Tennstaedt, Annette
2014-01-01
Transplanted stem cells can induce and enhance functional recovery in experimental stroke. Invasive analysis has been extensively used to provide detailed cellular and molecular characterization of the stroke pathology and engrafted stem cells. But post mortem analysis is not appropriate to reveal the time scale of the dynamic interplay between the cell graft, the ischemic lesion and the endogenous repair mechanisms. This review describes non-invasive imaging techniques which have been developed to provide complementary in vivo information. Recent advances were made in analyzing simultaneously different aspects of the cell graft (e.g., number of cells, viability state, and cell fate), the ischemic lesion (e.g., blood–brain-barrier consistency, hypoxic, and necrotic areas) and the neuronal and vascular network. We focus on optical methods, which permit simple animal preparation, repetitive experimental conditions, relatively medium-cost instrumentation and are performed under mild anesthesia, thus nearly under physiological conditions. A selection of recent examples of optical intrinsic imaging, fluorescence imaging and bioluminescence imaging to characterize the stroke pathology and engrafted stem cells are discussed. Special attention is paid to novel optimal reporter genes/probes for genetic labeling and tracking of stem cells and appropriate transgenic animal models. Requirements, advantages and limitations of these imaging platforms are critically discussed and placed into the context of other non-invasive techniques, e.g., magnetic resonance imaging and positron emission tomography, which can be joined with optical imaging in multimodal approaches. PMID:25177269
Automated palpation for breast tissue discrimination based on viscoelastic biomechanical properties.
Tsukune, Mariko; Kobayashi, Yo; Miyashita, Tomoyuki; Fujie, G Masakatsu
2015-05-01
Accurate, noninvasive methods are sought for breast tumor detection and diagnosis. In particular, a need for noninvasive techniques that measure both the nonlinear elastic and viscoelastic properties of breast tissue has been identified. For diagnostic purposes, it is important to select a nonlinear viscoelastic model with a small number of parameters that highly correlate with histological structure. However, the combination of conventional viscoelastic models with nonlinear elastic models requires a large number of parameters. A nonlinear viscoelastic model of breast tissue based on a simple equation with few parameters was developed and tested. The nonlinear viscoelastic properties of soft tissues in porcine breast were measured experimentally using fresh ex vivo samples. Robotic palpation was used for measurements employed in a finite element model. These measurements were used to calculate nonlinear viscoelastic parameters for fat, fibroglandular breast parenchyma and muscle. The ability of these parameters to distinguish the tissue types was evaluated in a two-step statistical analysis that included Holm's pairwise [Formula: see text] test. The discrimination error rate of a set of parameters was evaluated by the Mahalanobis distance. Ex vivo testing in porcine breast revealed significant differences in the nonlinear viscoelastic parameters among combinations of three tissue types. The discrimination error rate was low among all tested combinations of three tissue types. Although tissue discrimination was not achieved using only a single nonlinear viscoelastic parameter, a set of four nonlinear viscoelastic parameters were able to reliably and accurately discriminate fat, breast fibroglandular tissue and muscle.
Mark-recapture with multiple, non-invasive marks.
Bonner, Simon J; Holmberg, Jason
2013-09-01
Non-invasive marks, including pigmentation patterns, acquired scars, and genetic markers, are often used to identify individuals in mark-recapture experiments. If animals in a population can be identified from multiple, non-invasive marks then some individuals may be counted twice in the observed data. Analyzing the observed histories without accounting for these errors will provide incorrect inference about the population dynamics. Previous approaches to this problem include modeling data from only one mark and combining estimators obtained from each mark separately assuming that they are independent. Motivated by the analysis of data from the ECOCEAN online whale shark (Rhincodon typus) catalog, we describe a Bayesian method to analyze data from multiple, non-invasive marks that is based on the latent-multinomial model of Link et al. (2010, Biometrics 66, 178-185). Further to this, we describe a simplification of the Markov chain Monte Carlo algorithm of Link et al. (2010, Biometrics 66, 178-185) that leads to more efficient computation. We present results from the analysis of the ECOCEAN whale shark data and from simulation studies comparing our method with the previous approaches. © 2013, The International Biometric Society.
Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose
Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin
2011-01-01
This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4–5 times a day to check blood glucose levels—almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. PMID:21303640
Noninvasive blood glucose sensing on human body with near-infrared reflection spectroscopy
NASA Astrophysics Data System (ADS)
Huang, Zhen-hao; Hao, Chang-ning; Zhang, Lin-lin; Huang, Yan-chao; Shi, Yi-qin; Jiang, Geng-ru; Duan, Jun-li
2011-08-01
The non-invasive blood glucose sensing method has shown its high impact on the clinic application. This can make the measurement on the clinically relevant concentrations of glucose be free from the pain of patient. The transmission spectrum study indicates that the dependence of glucose concentration on the absorbance is in linear manner for the glucose concentration in the region of 30mg/dL to 4.5×104mg/dL. By the near infrared reflection spectroscopy of fiber spectrometer, the reflection band between 1.2μm and 1.35μm can be used to correlated with the glucose concentration in the range of 30 to 300 mg/dL. This reflection band is finally used to measure the glucose concentration effect in non-invasive manner, which gives the statistical significance of P value 0.02. Our experiment result shows that it is possible to get the glucose concentration by the near infrared reflection spectrum measurement on the human forefinger. This non-invasive blood glucose sensing method may useful in clinic after more experiment for different people.
Ding, Haiquan; Lu, Qipeng; Gao, Hongzhi; Peng, Zhongqi
2014-01-01
To facilitate non-invasive diagnosis of anemia, specific equipment was developed, and non-invasive hemoglobin (HB) detection method based on back propagation artificial neural network (BP-ANN) was studied. In this paper, we combined a broadband light source composed of 9 LEDs with grating spectrograph and Si photodiode array, and then developed a high-performance spectrophotometric system. By using this equipment, fingertip spectra of 109 volunteers were measured. In order to deduct the interference of redundant data, principal component analysis (PCA) was applied to reduce the dimensionality of collected spectra. Then the principal components of the spectra were taken as input of BP-ANN model. On this basis we obtained the optimal network structure, in which node numbers of input layer, hidden layer, and output layer was 9, 11, and 1. Calibration and correction sample sets were used for analyzing the accuracy of non-invasive hemoglobin measurement, and prediction sample set was used for testing the adaptability of the model. The correlation coefficient of network model established by this method is 0.94, standard error of calibration, correction, and prediction are 11.29g/L, 11.47g/L, and 11.01g/L respectively. The result proves that there exist good correlations between spectra of three sample sets and actual hemoglobin level, and the model has a good robustness. It is indicated that the developed spectrophotometric system has potential for the non-invasive detection of HB levels with the method of BP-ANN combined with PCA. PMID:24761296
Stasi, Cristina; Milani, Stefano
2016-01-28
The assessment of the fibrotic evolution of chronic hepatitis has always been a challenge for the clinical hepatologist. Over the past decade, various non-invasive methods have been proposed to detect the presence of fibrosis, including the elastometric measure of stiffness, panels of clinical and biochemical parameters, and combinations of both methods. The aim of this review is to analyse the most recent data on non-invasive techniques for the evaluation of hepatic fibrosis with particular attention to cost-effectiveness. We searched for relevant studies published in English using the PubMed database from 2009 to the present. A large number of studies have suggested that elastography and serum markers are useful techniques for diagnosing severe fibrosis and cirrhosis and for excluding significant fibrosis in hepatitis C virus patients. In addition, hepatic stiffness may also help to prognosticate treatment response to antiviral therapy. It has also been shown that magnetic resonance elastography has a high accuracy for staging and differentiating liver fibrosis. Finally, studies have shown that non-invasive methods are becoming increasingly precise in either positively identifying or excluding liver fibrosis, thus reducing the need for liver biopsy. However, both serum markers and transient elastography still have "grey area" values of lower accuracy. In this case, liver biopsy is still required to properly assess liver fibrosis. Recently, the guidelines produced by the World Health Organization have suggested that the AST-to-platelet ratio index or FIB-4 test could be utilised for the evaluation of liver fibrosis rather than other, more expensive non-invasive tests, such as elastography or FibroTest.
Stasi, Cristina; Milani, Stefano
2016-01-01
The assessment of the fibrotic evolution of chronic hepatitis has always been a challenge for the clinical hepatologist. Over the past decade, various non-invasive methods have been proposed to detect the presence of fibrosis, including the elastometric measure of stiffness, panels of clinical and biochemical parameters, and combinations of both methods. The aim of this review is to analyse the most recent data on non-invasive techniques for the evaluation of hepatic fibrosis with particular attention to cost-effectiveness. We searched for relevant studies published in English using the PubMed database from 2009 to the present. A large number of studies have suggested that elastography and serum markers are useful techniques for diagnosing severe fibrosis and cirrhosis and for excluding significant fibrosis in hepatitis C virus patients. In addition, hepatic stiffness may also help to prognosticate treatment response to antiviral therapy. It has also been shown that magnetic resonance elastography has a high accuracy for staging and differentiating liver fibrosis. Finally, studies have shown that non-invasive methods are becoming increasingly precise in either positively identifying or excluding liver fibrosis, thus reducing the need for liver biopsy. However, both serum markers and transient elastography still have “grey area” values of lower accuracy. In this case, liver biopsy is still required to properly assess liver fibrosis. Recently, the guidelines produced by the World Health Organization have suggested that the AST-to-platelet ratio index or FIB-4 test could be utilised for the evaluation of liver fibrosis rather than other, more expensive non-invasive tests, such as elastography or FibroTest. PMID:26819535
Non-invasive genetic censusing and monitoring of primate populations.
Arandjelovic, Mimi; Vigilant, Linda
2018-03-01
Knowing the density or abundance of primate populations is essential for their conservation management and contextualizing socio-demographic and behavioral observations. When direct counts of animals are not possible, genetic analysis of non-invasive samples collected from wildlife populations allows estimates of population size with higher accuracy and precision than is possible using indirect signs. Furthermore, in contrast to traditional indirect survey methods, prolonged or periodic genetic sampling across months or years enables inference of group membership, movement, dynamics, and some kin relationships. Data may also be used to estimate sex ratios, sex differences in dispersal distances, and detect gene flow among locations. Recent advances in capture-recapture models have further improved the precision of population estimates derived from non-invasive samples. Simulations using these methods have shown that the confidence interval of point estimates includes the true population size when assumptions of the models are met, and therefore this range of population size minima and maxima should be emphasized in population monitoring studies. Innovations such as the use of sniffer dogs or anti-poaching patrols for sample collection are important to ensure adequate sampling, and the expected development of efficient and cost-effective genotyping by sequencing methods for DNAs derived from non-invasive samples will automate and speed analyses. © 2018 Wiley Periodicals, Inc.
Motor abilities and anthropometrics in youth cross-country skiing.
Stöggl, R; Müller, E; Stöggl, T
2015-02-01
The purposes were to validate whether general motor abilities and anthropometrics are determinants of youth cross-country (XC) skiing performance; evaluate gender-specific differences; and to establish noninvasive diagnostics. Fifty-one youth XC skiers (34 boys; 13.8 ± 0.6 years and 17 girls; 13.4 ± 0.9 years) performed motor skill and laboratory tests, and anthropometric data were collected and correlated with XC skiing performance. Anthropometrics and maturity status were related to boys but not to girls XC skiing performance. Push-ups and 20-m sprint were correlated to XC skiing performance in both boys and girls. XC skiing performance of boys was predominantly influenced by upper body and trunk strength capacities (medicine ball throw, push-ups, and pull-ups) and jumping power (standing long and triple jump), whereas XC skiing of girls was mainly influenced by aerobic capacities (3000-m run). Laboratory measures did not reveal greater correlations to XC skiing performance compared with simple test concepts of speed, strength, and endurance. Maturity was a major confounding variable in boys but not girls. Use of noninvasive simple test concepts for determination of upper body strength, speed, and endurance represent practicable support for ski clubs, schools, or skiing federations in the guidance and evaluation of young talent, being aware of the effect of maturity especially in boys. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Shiha, G; Seif, S; Eldesoky, A; Elbasiony, M; Soliman, R; Metwally, A; Zalata, K; Mikhail, N
2017-05-01
A simple non-invasive score (Fibrofast, FIB-5) was developed using five routine laboratory tests (ALT, AST, alkaline phosphatase, albumin and platelets count) for the detection of significant hepatic fibrosis in patients with chronic hepatitis C. The FIB-4 index is a non-invasive test for the assessment of liver fibrosis, and a score of ≤1.45 enables the correct identification of patients who have non-significant (F0-1) from significant fibrosis (F2-4), and could avoid liver biopsy. The aim of this study was to compare the performance characteristics of FIB-5 and FIB-4 to differentiate between non-significant and significant fibrosis. A cross-sectional study included 604 chronic HCV patients. All liver biopsies were scored using the METAVIR system. Both FIB-5 and FIB-4 scores were measured and the performance characteristics were calculated using the ROC curve. The performance characteristics of FIB-5 at ≥7.5 and FIB-4 at ≤1.45 for the differentiation between non-significant fibrosis and significant fibrosis were: specificity 94.4%, PPV 85.7%, and specificity 54.9%, PPV 55.7% respectively. FIB-5 score at the new cutoff is superior to FIB-4 index for the differentiation between non-significant and significant fibrosis.
Evaluation of latex agglutination test (KAtex) for early diagnosis of kala-azar.
Ahsan, M M; Islam, M N; Mollah, A H; Hoque, M A; Hossain, M A; Begum, Z; Islam, M T
2010-07-01
Kala-azar is one of the major public health problem in Bangladesh. But the diagnosis of the problem often is difficult, unusual and time consuming, a simple, noninvasive, easy to perform, reliable and rapid diagnostic test has been a long-felt need of the clinicians. Therefore, the present study was conducted to see the sensitivity and specificity of Latex Agglutination test (KAtex) to detect leishmanial antigen from urine of kala-azar cases. The study was carried out in the department of Paediatrics, Mymensingh Medical College and Hospital, Bangladesh during July to December, 2008. A total of 100 urine samples were collected of which 50 were confirmed kala-azar cases and 50 were age and sex matched controls. Out of 50 kala-azar cases 47 showed positive result of KAtex. The test was also positive in 01 out of 30 healthy controls. None of the febrile controls was positive by KAtex. The sensitivity, specificity, positive predictive value and negative predictive value of the test using presence of LD bodies in splenic and/or bone marrow aspirate as gold standard were 94%, 98%, 97.91% and 94.23% respectively. KAtex is simple, noninvasive, easy to perform, rapid and reliable test for diagnosing kala-azar in endemic area and useful for small, less equipped laboratories as well as for the laboratories with better facilities.
Xun, Yun Hao; Fan, Jian Gao; Zang, Guo Qing; Liu, Hong; Jiang, Yan Ming; Xiang, Jing; Huang, Qian; Shi, Jun Ping
2012-11-01
To evaluate the diagnostic accuracy of some noninvasive fibrosis models in Chinese patients with nonalcoholic fatty liver disease (NAFLD). Consecutive biopsy-proven NAFLD patients were recruited from a single center from January 2005 to December 2010. Advanced fibrosis (stage 3 and 4) was defined using Kleiner criteria. The area under the receiver operating characteristic curve (AUROC) was used to compare the diagnostic accuracy of the NAFLD fibrosis score (NFS), FIB-4 index, aspartate transaminase (AST)/platelet ratio index (APRI), AST/alanine transaminase (ALT) ratio (AAR) and body mass index (BMI)-AAR-Diabetes (BARD) score. Of the patients with NAFLD, 79.6% were males with a mean age of 37.1 years, mean BMI of 26.1 kg/m(2) and 41.4% of them had nonalcoholic steatohepatitis, and 24 (15.8%) had advanced fibrosis. The AUROC of the FIB-4 index, APRI, AAR, NFS and BARD score for advanced fibrosis were 0.756, 0.742, 0.670, 0.653 and 0.642 (P < 0.05 for all), respectively. A concordant negative predictive value of approximately 90% was indicated whereas the positive predictive values were modest for all tests, and only the FIB-4 index yielded a higher positive likelihood ratio of 7.65. Using these cut-off values of tests for excluding advanced fibrosis could reduce the use of liver biopsy in 56.6-74.3% of the patients, with a minor false negative rate of 5.3-9.9%. Although slightly less accurate than liver biopsy, simple noninvasive tests can reliably exclude advanced fibrosis in Chinese NAFLD patients in our center. FIB-4 index performs better than the other tests under examination. © 2012 The Authors. Journal of Digestive Diseases © 2012 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
NMR fluid measurements of commonly used rat strains when subjected to SQ normotonic or hypertonic salines, as well as physiologic comparisons to sedentary and exercised subjects.This dataset is associated with the following publication:Gordon , C., P. Phillips , and A. Johnstone. A Noninvasive Method to Study Regulation of Extracellular Fluid Volume in Rats Using Nuclear Magnetic Resonance. American Journal of Physiology- Renal Physiology. American Physiological Society, Bethesda, MD, USA, 310(5): 426-31, (2016).
Mahoney, Anne M; Stimpson, Claudia L; Scott, Karen L; Hampson, Neil B
2007-12-01
The diffusing capacity of the lungs for carbon monoxide (D(LCO)) is commonly measured during pulmonary function testing (PFT). Although adjustment of the measured D(LCO) for an elevated baseline carboxyhemoglobin level is recommended, carboxyhemoglobin is not routinely measured, which may reduce the accuracy of D(LCO) measurements. We sought to assess the utility of routine carboxyhemoglobin measurement and subsequent D(LCO) correction in patients referred for PFT. We retrospectively reviewed 100 consecutive PFT results, including D(LCO) assessment. We used a pulse CO-oximeter (recently approved by the Food and Drug Administration) to noninvasively measure baseline carboxyhemoglobin (S(pCO)). We used simple descriptive statistics to compare the S(pCO) values. In subjects with elevated S(pCO) (> 2%) we adjusted the percent-of-predicted D(LCO). Interpretation of D(LCO) was categorized according to the American Thoracic Society classification scheme for respiratory impairment. The self-reported smokers had higher average S(pCO) than did self-reported nonsmokers (1.6% vs 3.5%, p < 0.001), although 14% of nonsmokers had an elevated S(pCO) and 26% of smokers had normal S(pCO). When the D(LCO) was corrected for elevated S(pCO), 2 patients moved from a category of moderate impairment to mild impairment. Both were smokers. The noninvasive measurement of carboxyhemoglobin is easy to perform during PFT. When precise measurement of D(LCO) is important, noninvasive measurement of carboxyhemoglobin may be of value. If routine S(pCO) measurement is considered, the highest yield is among current smokers.
Hassaninia, Iman; Bostanabad, Ramin; Chen, Wei; Mohseni, Hooman
2017-11-10
Fabricated tissue phantoms are instrumental in optical in-vitro investigations concerning cancer diagnosis, therapeutic applications, and drug efficacy tests. We present a simple non-invasive computational technique that, when coupled with experiments, has the potential for characterization of a wide range of biological tissues. The fundamental idea of our approach is to find a supervised learner that links the scattering pattern of a turbid sample to its thickness and scattering parameters. Once found, this supervised learner is employed in an inverse optimization problem for estimating the scattering parameters of a sample given its thickness and scattering pattern. Multi-response Gaussian processes are used for the supervised learning task and a simple setup is introduced to obtain the scattering pattern of a tissue sample. To increase the predictive power of the supervised learner, the scattering patterns are filtered, enriched by a regressor, and finally characterized with two parameters, namely, transmitted power and scaled Gaussian width. We computationally illustrate that our approach achieves errors of roughly 5% in predicting the scattering properties of many biological tissues. Our method has the potential to facilitate the characterization of tissues and fabrication of phantoms used for diagnostic and therapeutic purposes over a wide range of optical spectrum.
Galbiati, Silvia; Stenirri, Stefania; Sbaiz, Luca; Barberis, Marco; Cremonesi, Laura; Restagno, Gabriella; Ferrari, Maurizio
2014-04-01
Non-invasive prenatal diagnosis has found application in a limited number of genetic diseases due to the difficulty in detecting a few copies of fetal mutated sequences in the presence of a large excess of wild-type maternal alleles, even in the case of single-base mutations. We developed conditions for the enrichment of fetal mutated alleles in maternal plasma based on CO-amplification at lower denaturation temperature-PCR (COLD-PCR). In particular, we applied a full COLD-PCR protocol to the identification of a p.A87_G92del mutation in the TWIST1 gene causing craniosynostosis in a couple at risk for the disease. The use of the COLD-PCR protocol coupled with direct sequencing enabled correct identification of the fetal paternally inherited mutated allele, in accordance with the result obtained on DNA extracted from chorionic villi. COLD-PCR proved to be a simple and powerful tool for the identification of minority mutated alleles even in the case of a moderately large deletion (18 bp) and confirmed to be very suitable for non-invasive prenatal diagnosis of a variety of genetic diseases.
A 3D-Printed Sensor for Monitoring Biosignals in Small Animals
Byun, Donghak; Choi, Seok-Yong; Lee, Byung-Geun; Kim, Myeong-Kyu
2017-01-01
Although additive manufacturing technologies, also known as 3D printing, were first introduced in the 1980s, they have recently gained remarkable popularity owing to decreased costs. 3D printing has already emerged as a viable technology in many industries; in particular, it is a good replacement for microfabrication technology. Microfabrication technology usually requires expensive clean room equipment and skilled engineers; however, 3D printing can reduce both cost and time dramatically. Although 3D printing technology has started to emerge into microfabrication manufacturing and medical applications, it is typically limited to creating mechanical structures such as hip prosthesis or dental implants. There have been increased interests in wearable devices and the critical part of such wearable devices is the sensing part to detect biosignals noninvasively. In this paper, we have built a 3D-printed sensor that can measure electroencephalogram and electrocardiogram from zebrafish. Despite measuring biosignals noninvasively from zebrafish has been known to be difficult due to that it is an underwater creature, we were able to successfully obtain electrophysiological information using the 3D-printed sensor. This 3D printing technique can accelerate the development of simple noninvasive sensors using affordable equipment and provide an economical solution to physiologists who are unfamiliar with complicated microfabrication techniques. PMID:29209491
Non-invasive molecular imaging for preclinical cancer therapeutic development
O'Farrell, AC; Shnyder, SD; Marston, G; Coletta, PL; Gill, JH
2013-01-01
Molecular and non-invasive imaging are rapidly emerging fields in preclinical cancer drug discovery. This is driven by the need to develop more efficacious and safer treatments, the advent of molecular-targeted therapeutics, and the requirements to reduce and refine current preclinical in vivo models. Such bioimaging strategies include MRI, PET, single positron emission computed tomography, ultrasound, and optical approaches such as bioluminescence and fluorescence imaging. These molecular imaging modalities have several advantages over traditional screening methods, not least the ability to quantitatively monitor pharmacodynamic changes at the cellular and molecular level in living animals non-invasively in real time. This review aims to provide an overview of non-invasive molecular imaging techniques, highlighting the strengths, limitations and versatility of these approaches in preclinical cancer drug discovery and development. PMID:23488622
Noninvasive physiologic assessment of coronary stenoses using cardiac CT.
Xu, Lei; Sun, Zhonghua; Fan, Zhanming
2015-01-01
Coronary CT angiography (CCTA) has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD). CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive "one-stop-shop" diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT), and transluminal attenuation gradient (TAG), CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.
Manzano-Szalai, Krisztina; Pali-Schöll, Isabella; Krishnamurthy, Durga; Stremnitzer, Caroline; Flaschberger, Ingo; Jensen-Jarolim, Erika
2016-01-01
In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i) milk allergy, ii) peanut allergy and iii) egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour. PMID:26963393
Analysis of biomedical time signals for characterization of cutaneous diabetic micro-angiopathy
NASA Astrophysics Data System (ADS)
Kraitl, Jens; Ewald, Hartmut
2007-02-01
Photo-plethysmography (PPG) is frequently used in research on microcirculation of blood. It is a non-invasive procedure and takes minimal time to be carried out. Usually PPG time series are analyzed by conventional linear methods, mainly Fourier analysis. These methods may not be optimal for the investigation of nonlinear effects of the hearth circulation system like vasomotion, autoregulation, thermoregulation, breathing, heartbeat and vessels. The wavelet analysis of the PPG time series is a specific, sensitive nonlinear method for the in vivo identification of hearth circulation patterns and human health status. This nonlinear analysis of PPG signals provides additional information which cannot be detected using conventional approaches. The wavelet analysis has been used to study healthy subjects and to characterize the health status of patients with a functional cutaneous microangiopathy which was associated with diabetic neuropathy. The non-invasive in vivo method is based on the radiation of monochromatic light through an area of skin on the finger. A Photometrical Measurement Device (PMD) has been developed. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values and blood circulation patterns.
Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.
Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi
2011-01-01
Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.
Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C
2011-01-01
Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.
NASA Technical Reports Server (NTRS)
Cantrell, John H. (Inventor); Yost, William T. (Inventor)
1994-01-01
Non-invasive measuring devices responsive to changes in a patient's intracranial pressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the patient on a tilting bed and calculating a change in ICP from the tilt angle and the length of the patient's cerebrospinal column, or by placing a pressurized skull cap on the patient and measuring the inflation pressure. Absolute values for the patient's pressure-volume index (PVI) and the steady state ICP can then be determined by inducing two known changes in the volume of cerebrospinal fluid while recording the corresponding changes in ICP by means of the calibrated measuring device. The two pairs of data for pressure change and volume change are entered into an equation developed from an equation describing the relationship between ICP and cerebrospinal fluid volume. PVI and steady state ICP are then determined by solving the equation. Methods for inducing known changes in cerebrospinal fluid volume are described.
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)
1997-01-01
Non-invasive measuring devices responsive to changes in a patient's intracranial pressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the patient on a tilting bed and calculating a change in ICP from the tilt angle and the length of the patient's cerebrospinal column, or by placing a pressurized skull cap on the patient and measuring the inflation pressure. Absolute values for the patient's pressure-volume index (PVI) and the steady state ICP can then be determined by inducing two known changes in the volume of cerebrospinal fluid while recording the corresponding changes in ICP by means of the calibrated measuring device. The two pairs of data for pressure change and volume change are entered into an equation developed from an equation describing the relationship between ICP and cerebrospinal fluid volume. PVI and steady state ICP are then determined by solving the equation. Methods for inducing known changes in cerebrospinal fluid volume are described.
A Noninvasive Imaging Modality for Cardiac Arrhythmias
Burnes, John E.; Taccardi, Bruno; Rudy, Yoram
2007-01-01
Background The last decade witnessed an explosion of information regarding the genetic, molecular, and mechanistic basis of heart disease. Translating this information into clinical practice requires the development of novel functional imaging modalities for diagnosis, localization, and guided intervention. A noninvasive modality for imaging cardiac arrhythmias is not yet available. Present electrocardiographic methods cannot precisely localize a ventricular tachycardia (VT) or its key reentrant circuit components. Recently, we developed a noninvasive electrocardiographic imaging modality (ECGI) that can reconstruct epicardial electrophysiological information from body surface potentials. Here, we extend its application to image reentrant arrhythmias. Methods and Results Epicardial potentials were recorded during VT with a 490 electrode sock during an open chest procedure in 2 dogs with 4-day-old myocardial infarctions. Body surface potentials were generated from these epicardial potentials in a human torso model. Realistic geometry errors and measurement noise were added to the torso data, which were then used to noninvasively reconstruct epicardial isochrones, electrograms, and potentials with excellent accuracy. ECGI reconstructed the reentry pathway and its key components, including (1) the central common pathway, (2) the VT exit site, (3) lines of block, and (4) regions of slow and fast conduction. This allowed for detailed characterization of the reentrant circuit morphology. Conclusions ECGI can noninvasively image arrhythmic activation on the epicardium during VT to identify and localize key components of the arrhythmogenic pathway that can be effective targets for antiarrhythmic intervention. PMID:11044435
Non-invasive monitoring of spreading depression.
Bastany, Zoya J R; Askari, Shahbaz; Dumont, Guy A; Speckmann, Erwin-Josef; Gorji, Ali
2016-10-01
Spreading depression (SD), a slow propagating depolarization wave, plays an important role in pathophysiology of different neurological disorders. Yet, research into SD-related disorders has been hampered by the lack of non-invasive recording techniques of SD. Here we compared the manifestations of SD in continuous non-invasive electroencephalogram (EEG) recordings to invasive electrocorticographic (ECoG) recordings in order to obtain further insights into generator structures and electrogenic mechanisms of surface recording of SD. SD was induced by KCl application and simultaneous SD recordings were performed by scalp EEG as well as ECoG electrodes of somatosensory neocortex of rats using a novel homemade EEG amplifier, AgCl recording electrodes, and high chloride conductive gel. Different methods were used to analyze the data; including the spectrogram, bi-spectrogram, pattern distribution, relative spectrum power, and multivariable Gaussian fit analysis. The negative direct current (DC) shifts recorded by scalp electrodes exhibited a high homogeneity to those recorded by ECoG electrodes. Furthermore, this novel method of recording and analysis was able to separate SD recorded by scalp electrodes from non-neuronal DC shifts induced by other potential generators, such as the skin, muscles, arteries, dura, etc. These data suggest a novel application for continuous non-invasive monitoring of DC potential changes, such as SD. Non-invasive monitoring of SD would allow early intervention and improve outcome in SD-related neurological disorders. Copyright © 2016 IBRO. All rights reserved.
Monte Carlo simulation of non-invasive glucose measurement based on FMCW LIDAR
NASA Astrophysics Data System (ADS)
Xiong, Bing; Wei, Wenxiong; Liu, Nan; He, Jian-Jun
2010-11-01
Continuous non-invasive glucose monitoring is a powerful tool for the treatment and management of diabetes. A glucose measurement method, with the potential advantage of miniaturizability with no moving parts, based on the frequency modulated continuous wave (FMCW) LIDAR technology is proposed and investigated. The system mainly consists of an integrated near-infrared tunable semiconductor laser and a detector, using heterodyne technology to convert the signal from time-domain to frequency-domain. To investigate the feasibility of the method, Monte Carlo simulations have been performed on tissue phantoms with optical parameters similar to those of human interstitial fluid. The simulation showed that the sensitivity of the FMCW LIDAR system to glucose concentration can reach 0.2mM. Our analysis suggests that the FMCW LIDAR technique has good potential for noninvasive blood glucose monitoring.
Sheridan, David A; Aithal, Guru; Alazawi, William; Allison, Michael; Anstee, Quentin; Cobbold, Jeremy; Khan, Shahid; Fowell, Andrew; McPherson, Stuart; Newsome, Philip N; Oben, Jude; Tomlinson, Jeremy; Tsochatzis, Emmanouil
2017-10-01
Guidelines for the assessment of non-alcoholic fatty liver disease (NAFLD) have been published in 2016 by National Institute for Health and Care Excellence and European Associations for the study of the Liver-European Association for the study of Diabetes-European Association for the study of Obesity. Prior to publication of these guidelines, we performed a cross-sectional survey of gastroenterologists and hepatologists regarding NAFLD diagnosis and management. An online survey was circulated to members of British Association for the Study of the Liver and British Society of Gastroenterology between February 2016 and May 2016. 175 gastroenterologists/hepatologists responded, 116 completing the survey, representing 84 UK centres. 22% had local NAFLD guidelines. 45% received >300 referrals per year from primary care for investigation of abnormal liver function tests (LFTs). Clinical assessment tended to be performed in secondary rather than primary care including body mass index (82% vs 26%) and non-invasive liver screen (86% vs 32%) and ultrasound (81% vs 37%). Widely used tools for non-invasive fibrosis risk stratification were aspartate transaminase (AST)/alanine transaminase (ALT) ratio (53%), Fibroscan (50%) and NAFLD fibrosis score (41%). 78% considered liver biopsy in selected cases. 50% recommended 10% weight loss target as first-line treatment. Delivery of lifestyle interventions was mostly handed back to primary care (56%). A minority have direct access to community weight management services (22%). Follow-up was favoured by F3/4 fibrosis (72.9%), and high-risk non-invasive fibrosis tests (51%). Discharge was favoured by simple steatosis at biopsy (30%), and low-risk non-invasive scores (25%). The survey highlights areas for improvement of service provision for NAFLD assessment including improved recognition of non-alcoholic steatohepatitis in people with type 2 diabetes, streamlining abnormal LFT referral pathways, defining non-invasive liver fibrosis assessment tools, use of liver biopsy, managing metabolic syndrome features and improved access to lifestyle interventions.
NASA Astrophysics Data System (ADS)
Yuan, Yi; Chen, Yudong; Li, Xiaoli
2016-02-01
A novel technique, transcranial focused ultrasonic-magnetic stimulation (tFUMS), has been developed for noninvasive brain modulation in vivo. tFUMS has a higher spatial resolution (<2 mm) and a higher penetration depth than other noninvasive neuromodulation methods. The in vivo animal experimental results show that tFUMS can not only increase the power of local field potentials and the firing rate of the neurons, but also enhance the effect of transcranial focused ultrasound stimulation on the neuromodulation. The results demonstrate that tFUMS can modulate brain oscillatory activities by stimulating brain tissues.
Vyas, Kaetan J.; Danz, David; Gilman, Robert H.; Wise, Robert A.; León-Velarde, Fabiola; Jaime Miranda, J.
2015-01-01
Abstract Vyas, Kaetan J., David Danz, Robert H. Gilman, Robert A. Wise, Fabiola León-Velarde, J. Jaime Miranda, and William Checkley. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt Med Biol 16:162–168, 2015.—Globally, over 140 million people are at risk of developing chronic mountain sickness, a common maladaptation to life at high altitude (>2500 meters above sea level). The diagnosis is contingent upon the identification of excessive erythrocytosis (EE). Current best practices to identify EE require a venous blood draw, which is cumbersome for large-scale surveillance. We evaluated two point-of-care biomarkers to screen for EE: noninvasive spot-check tests of total hemoglobin and oxyhemoglobin saturation (Pronto-7, Masimo Corporation). We conducted paired evaluations of total serum hemoglobin from a venous blood draw and noninvasive, spot-check testing of total hemoglobin and oxyhemoglobin saturation with the Pronto-7 in 382 adults aged ≥35 years living in Puno, Peru (3825 meters above sea level). We used the Bland-Altman method to measure agreement between the noninvasive hemoglobin assessment and the gold standard lab hemoglobin analyzer. Mean age was 58.8 years and 47% were male. The Pronto-7 test was unsuccessful in 21 (5%) participants. Limits of agreement between total hemoglobin measured via venous blood draw and the noninvasive, spot-check test ranged from −2.8 g/dL (95% CI −3.0 to −2.5) to 2.5 g/dL (95% CI 2.2 to 2.7), with a bias of −0.2 g/dL (95% CI −0.3 to −0.02) for the difference between total hemoglobin and noninvasive hemoglobin concentrations. Overall, the noninvasive spot-check test of total hemoglobin had a better area under the receiver operating characteristic curve compared to oxyhemoglobin saturation for the identification of EE as measured by a gold standard laboratory hemoglobin analyzer (0.96 vs. 0.82; p<0.001). Best cut-off values to screen for EE with the Pronto 7 were ≥19.9 g/dL in males and ≥17.5 g/dL in females. At these cut-points, sensitivity and specificity were both 92% and 89% for males and females, respectively. A noninvasive, spot-check test of total hemoglobin had low bias and high discrimination for the detection of EE in high altitude Peru, and may be a useful point-of-care tool for large-scale surveillance in high-altitude settings. PMID:25973777
Evaluation of noninvasive cardiac output methods during exercise
NASA Technical Reports Server (NTRS)
Moore, Alan D.; Barrows, Linda H.; Rashid, Michael; Siconolfi, Steven F.
1992-01-01
Noninvasive techniques to estimate cardiac output (Qc) will be used during future space flight. This retrospective literature survey compared the Qc techniques of carbon dioxide rebreathing (CO2-R), CO2 single breath (CO2-S), Doppler (DOP), impedance (IM), and inert gas (IG: acetylene or nitrous oxide) to direct (DIR) assessments measured at rest and during exercise.
USDA-ARS?s Scientific Manuscript database
White-tailed deer (WTD; Odocoileus virginianus) can act as a reservoir for bovine tuberculosis (bTB), caused by Mycobacterium bovis, and can be a source of infection in cattle. Presently, no method exists to noninvasively monitor the presence of bTB in wildlife. In addition, due to similarities betw...
USDA-ARS?s Scientific Manuscript database
Skin is a relatively stable storage medium for carotenoids; non-invasive optical measurements of carotenoids in this tissue via Resonance Raman spectroscopy (RRS) serve as a non-invasive biomarker for fruit and vegetable (F/V) intake. The RRS method has been validated with HPLC-based measurements of...
Predicting carnivore occurrence with noninvasive surveys and occupancy modeling
Robert Long; Therese Donovan; Paula MacKay; William Zielinski; Jeffrey Buzas
2011-01-01
Terrestrial carnivores typically have large home ranges and exist at low population densities, thus presenting challenges to wildlife researchers. We employed multiple, noninvasive survey methodsâscat detection dogs, remote cameras, and hair snaresâto collect detectionânondetection data for elusive American black bears (Ursus americanus), fishers...
Ma, Qiaoli; Andina, Diana; Leroux, Jean-Christophe; Detmar, Michael
2017-01-01
Optical imaging methods have been developed to measure lymphatic function in skin; however, the lymphatic system of many organs is not accessible to this technology. Since lymphatic transport of macromolecules from any organ proceeds to the blood circulation, we aimed to develop a method that can measure lymphatic function by monitoring the fluorescence in a superficial vein of an interstitially injected tracer. We selected a 40-kDa PEGylated near-infrared dye conjugate, as it showed lymphatic system–specific uptake and extended circulation in blood. Lymphatic transport to blood from subcutaneous tissue required a transit time before signal enhancement was seen in blood followed by a steady rise in signal over time. Increased lymphatic transport was apparent in awake mice compared with those under continuous anesthesia. The methods were validated in K14-VEGFR-3-Fc and K14-VEGF-C transgenic mice with loss and gain of lymphatic function, respectively. Reduced lymphatic transport to blood was also found in aged mice. The technique was also able to measure lymphatic transport from the peritoneal cavity, a location not suitable for optical imaging. The method is a promising, simple approach for assessment of lymphatic function and for monitoring of therapeutic regimens in mouse models of disease and may have potential for clinical translation. PMID:28097238
Down syndrome detection from facial photographs using machine learning techniques
NASA Astrophysics Data System (ADS)
Zhao, Qian; Rosenbaum, Kenneth; Sze, Raymond; Zand, Dina; Summar, Marshall; Linguraru, Marius George
2013-02-01
Down syndrome is the most commonly occurring chromosomal condition; one in every 691 babies in United States is born with it. Patients with Down syndrome have an increased risk for heart defects, respiratory and hearing problems and the early detection of the syndrome is fundamental for managing the disease. Clinically, facial appearance is an important indicator in diagnosing Down syndrome and it paves the way for computer-aided diagnosis based on facial image analysis. In this study, we propose a novel method to detect Down syndrome using photography for computer-assisted image-based facial dysmorphology. Geometric features based on facial anatomical landmarks, local texture features based on the Contourlet transform and local binary pattern are investigated to represent facial characteristics. Then a support vector machine classifier is used to discriminate normal and abnormal cases; accuracy, precision and recall are used to evaluate the method. The comparison among the geometric, local texture and combined features was performed using the leave-one-out validation. Our method achieved 97.92% accuracy with high precision and recall for the combined features; the detection results were higher than using only geometric or texture features. The promising results indicate that our method has the potential for automated assessment for Down syndrome from simple, noninvasive imaging data.
Janzen, Nils; Hofmann, Alejandro D; Schmidt, Gunnar; Das, Anibh M; Illsinger, Sabine
2017-12-21
The aim of the present study was to establish a non-invasive, fast and robust enzymatic assay to confirm fatty acid oxidation defects (FAOD) in humans following informative newborn-screening or for selective screening of patients suspected to suffer from FAOD. The reliability of this method was tested in whole blood from FAOD patients with specific enzymatic defects. Whole blood samples were assayed in 30 medium chain- (MCADD, age 0 to 17 years), 6 very long chain- (VLCADD, age 0 to 4 years), 6 long chain hydroxy- (LCHAD, age 1 to 6 years), 3 short chain- (SCADD, age 10 to 13 years) acyl-CoA-dehydrogenase- and 2 primary carnitine transporter deficiencies (CTD, age 3 to 5 years). Additionally, 26 healthy children (age 0 to 17 years) served as controls. Whole blood samples were incubated with stable end-labeled palmitate; labeled acylcarnitines were analyzed by tandem mass spectrometry and compared with controls and between patient groups (Mann-Whitney Rank Sum Test). Concentrations of specific labeled acylcarnitine metabolites were compared between particular underlying MCADD- (ANOVA), VLCADD- and LCHADD- genetic variants (descriptive data analysis). 11 different acylcarnitines were analyzed. MCADD- (C8-, C10-carnitine, C8/C10- and C8/C4-carnitine), VLCADD- (C12-, C14:1-, C14:2-carnitine, C14:1/C12- and C14:2/C12-carnitine), LCHADD (C16-OH-carnitine) as well as CTD- deficiency (sum of all acylcarnitines) samples could be clearly identified and separated from control values as well as other FAOD, whereas the sum of all acylcarnitines was not conclusive between FAOD samples. Furthermore, C4- (SCADD), C14- (VLCADD) and C14-OH-carnitines (LCHADD) were discriminating between the FAOD groups. Metabolic parameters did not differ significantly between underlying MCADD variants; similar results could be observed for VLCADD- and LCHADD- variants. This functional method in whole blood samples is relatively simple, non-invasive and little time consuming. It allows to identify MCADD-, VLCADD-, LCHADD- and carnitine transporter deficiencies. The genetic phenotypes of one enzyme defect did not result in differing acylcarnitine patterns in MCADD, VLCADD or LCHADD in vitro.
Non-invasive reproductive and stress endocrinology in amphibian conservation physiology
Narayan, E. J.
2013-01-01
Non-invasive endocrinology utilizes non-invasive biological samples (such as faeces, urine, hair, aquatic media, and saliva) for the quantification of hormones in wildlife. Urinary-based enzyme immunoassay (EIA) and radio-immunoassay have enabled the rapid quantification of reproductive and stress hormones in amphibians (Anura: Amphibia). With minimal disturbance, these methods can be used to assess the ovarian and testicular endocrine functions as well as physiological stress in captive and free-living populations. Non-invasive endocrine monitoring has therefore greatly advanced our knowledge of the functioning of the stress endocrine system (the hypothalamo–pituitary–interrenal axis) and the reproductive endocrine system (the hypothalamo–pituitary–gonadal axis) in the amphibian physiological stress response, reproductive ecology, health and welfare, and survival. Biological (physiological) validation is necessary for obtaining the excretory lag time of hormone metabolites. Urinary-based EIA for the major reproductive hormones, estradiol and progesterone in females and testosterone in males, can be used to track the reproductive hormone profiles in relationship to reproductive behaviour and environmental data in free-living anurans. Urinary-based corticosterone metabolite EIA can be used to assess the sublethal impacts of biological stressors (such as invasive species and pathogenic diseases) as well as anthropogenic induced environmental stressors (e.g. extreme temperatures) on free-living populations. Non-invasive endocrine methods can also assist in the diagnosis of success or failure of captive breeding programmes by measuring the longitudinal patterns of changes in reproductive hormones and corticosterone within captive anurans and comparing the endocrine profiles with health records and reproductive behaviour. This review paper focuses on the reproductive and the stress endocrinology of anurans and demonstrates the uses of non-invasive endocrinology for advancing amphibian conservation physiology. It also provides key technical considerations for future research that will increase the accuracy and reliability of the data and the value of non-invasive endocrinology within the conceptual framework of conservation physiology. PMID:27293595
Hydrogen peroxide test for intraoperative bile leak detection.
Trehan, V; Rao, Pankaj P; Naidu, C S; Sharma, Anuj K; Singh, A K; Sharma, Sanjay; Gaur, Amit; Kulkarni, S V; Pathak, N
2017-07-01
Bile leakage (BL) is a common complication following liver surgery, ranging from 3 to 27% in different series. To reduce the incidence of post-operative BL various BL tests have been applied since ages, but no method is foolproof and every method has their own limitations. In this study we used a relatively simpler technique to detect the BL intra-operatively. Topical application of 1.5% diluted hydrogen peroxide (H 2 O 2 ) was used to detect the BL from cut surface of liver and we compared this with conventional saline method to know the efficacy. A total of 31 patients included all patients who underwent liver resection and donor hepatectomies as part of Living Donor Liver Transplantation. After complete liver resection, the conventional saline test followed by topical diluted 1.5% H 2 O 2 test was performed on all. A BL was demonstrated in 11 patients (35.48%) by the conventional saline method and in 19 patients (61.29%) by H 2 O 2 method. Statistically compared by Wilcoxon signed-rank test showed significant difference ( P = 0.014) for minor liver resections group and ( P = 0.002) for major liver resections group. The topical application of H 2 O 2 is a simple and effective method of detection of BL from cut surface of liver. It is an easy, non-invasive, cheap, less time consuming, reproducible, and sensitive technique with no obvious disadvantages.
Granular convection observed by magnetic resonance imaging.
Ehrichs, E E; Jaeger, H M; Karczmar, G S; Knight, J B; Kuperman, V Y; Nagel, S R
1995-03-17
Vibrations in a granular material can spontaneously produce convection rolls reminiscent of those seen in fluids. Magnetic resonance imaging provides a sensitive and noninvasive probe for the detection of these convection currents, which have otherwise been difficult to observe. A magnetic resonance imaging study of convection in a column of poppy seeds yielded data about the detailed shape of the convection rolls and the depth dependence of the convection velocity. The velocity was found to decrease exponentially with depth; a simple model for this behavior is presented here.
Changing Brain Networks Through Non-invasive Neuromodulation
To, Wing Ting; De Ridder, Dirk; Hart Jr., John; Vanneste, Sven
2018-01-01
Background/Objective: Non-invasive neuromodulation techniques, such as repetitive Transcranial Magnetic Stimulation (rTMS) and transcranial Direct Current Stimulation (tDCS), have increasingly been investigated for their potential as treatments for neurological and psychiatric disorders. Despite widespread dissemination of these techniques, the underlying therapeutic mechanisms and the ideal stimulation site for a given disorder remain unknown. Increasing evidence support the possibility of non-invasive neuromodulation affecting a brain network rather than just the local stimulation target. In this article, we present evidence in a clinical setting to support the idea that non-invasive neuromodulation changes brain networks. Method: This article addresses the idea that non-invasive neuromodulation modulates brain networks, rather than just the local stimulation target, using neuromodulation studies in tinnitus and major depression as examples. We present studies that support this hypothesis from different perspectives. Main Results/Conclusion: Studies stimulating the same brain region, such as the dorsolateral prefrontal cortex (DLPFC), have shown to be effective for several disorders and studies using different stimulation sites for the same disorder have shown similar results. These findings, as well as results from studies investigating brain network connectivity on both macro and micro levels, suggest that non-invasive neuromodulation affects a brain network rather than just the local stimulation site targeted. We propose that non-invasive neuromodulation should be approached from a network perspective and emphasize the therapeutic potential of this approach through the modulation of targeted brain networks. PMID:29706876
Changing Brain Networks Through Non-invasive Neuromodulation.
To, Wing Ting; De Ridder, Dirk; Hart, John; Vanneste, Sven
2018-01-01
Background/Objective : Non-invasive neuromodulation techniques, such as repetitive Transcranial Magnetic Stimulation (rTMS) and transcranial Direct Current Stimulation (tDCS), have increasingly been investigated for their potential as treatments for neurological and psychiatric disorders. Despite widespread dissemination of these techniques, the underlying therapeutic mechanisms and the ideal stimulation site for a given disorder remain unknown. Increasing evidence support the possibility of non-invasive neuromodulation affecting a brain network rather than just the local stimulation target. In this article, we present evidence in a clinical setting to support the idea that non-invasive neuromodulation changes brain networks. Method : This article addresses the idea that non-invasive neuromodulation modulates brain networks, rather than just the local stimulation target, using neuromodulation studies in tinnitus and major depression as examples. We present studies that support this hypothesis from different perspectives. Main Results/Conclusion : Studies stimulating the same brain region, such as the dorsolateral prefrontal cortex (DLPFC), have shown to be effective for several disorders and studies using different stimulation sites for the same disorder have shown similar results. These findings, as well as results from studies investigating brain network connectivity on both macro and micro levels, suggest that non-invasive neuromodulation affects a brain network rather than just the local stimulation site targeted. We propose that non-invasive neuromodulation should be approached from a network perspective and emphasize the therapeutic potential of this approach through the modulation of targeted brain networks.
Wang, Wenjuan; Yuan, Yuan; Zheng, Haiqing; Wang, Yaoshen; Zeng, Dan; Yang, Yihua; Yi, Xin; Xia, Yang; Zhu, Chunjiang
2017-07-01
Thalassemia is a dangerous hematolytic genetic disease. In south China, ∼24% Chinese carry alpha-thalassemia or beta-thalassemia gene mutations. Given the fact that the invasive sampling procedures can only be performed by professionals in experienced centers, it may increase the risk of miscarriage or infection. Thus, most people are worried about the invasive operation. As such, a noninvasive and accurate prenatal diagnosis is needed for appropriate genetic counseling for families with high risks. Here we sought to develop capture probes and their companion analysis methods for the noninvasive prenatal detection of deletional and nondeletional thalassemia. Two families diagnosed as carriers of either beta-thalassemia gene or Southeast Asian deletional alpha-thalassemia gene mutation were recruited. The maternal plasma and amniotic fluid were collected for prenatal diagnosis. Probes targeting exons of the genes of interest and the highly heterozygous SNPs within the 1Mb flanking region were designed. The target capture sequencing was performed with plasma DNA from the pregnant woman and genomic DNA from the couples and their children. Then the parental haplotype was constructed by the trios-based strategy. The fetal haplotype was deduced from the parental haplotype with a hidden Markov model-based algorithm. The fetal genotypes were successfully deduced in both families noninvasively. The noninvasively constructed haplotypes of both fetuses were identical to the invasive prenatal diagnosis results with an accuracy rate of 100% in the target region. Our study demonstrates that the effective noninvasive prenatal diagnosis of alpha-thalassemia and beta-thalassemia can be achieved with the targeted capture sequencing and the haplotype-assisted analysis method.
Noninvasive bi-graphical analysis for the quantification of slowly reversible radioligand binding
NASA Astrophysics Data System (ADS)
Seo, Seongho; Kim, Su Jin; Yoo, Hye Bin; Lee, Jee-Young; Kyeong Kim, Yu; Lee, Dong Soo; Zhou, Yun; Lee, Jae Sung
2016-09-01
In this paper, we presented a novel reference-region-based (noninvasive) bi-graphical analysis for the quantification of a reversible radiotracer binding that may be too slow to reach relative equilibrium (RE) state during positron emission tomography (PET) scans. The proposed method indirectly implements the noninvasive Logan plot, through arithmetic combination of the parameters of two other noninvasive methods and the apparent tissue-to-plasma efflux rate constant for the reference region (k2\\prime ). We investigated its validity and statistical properties, by performing a simulation study with various noise levels and k2\\prime values, and also evaluated its feasibility for [18F]FP-CIT PET in human brain. The results revealed that the proposed approach provides distribution volume ratio estimation comparable to the Logan plot at low noise levels while improving underestimation caused by non-RE state differently depending on k2\\prime . Furthermore, the proposed method was able to avoid noise-induced bias of the Logan plot, and the variability of its results was less dependent on k2\\prime than the Logan plot. Therefore, this approach, without issues related to arterial blood sampling given a pre-estimate of k2\\prime (e.g. population-based), could be useful in parametric image generation for slow kinetic tracers staying in a non-RE state within a PET scan.
NASA Astrophysics Data System (ADS)
Dorshow, Richard B.; Fitch, Richard M.; Galen, Karen P.; Wojdyla, Jolette K.; Poreddy, Amruta R.; Freskos, John N.; Rajagopalan, Raghavan; Shieh, Jeng-Jong; Demirjian, Sevag G.
2013-02-01
Renal function assessment is needed for the detection of acute kidney injury and chronic kidney disease. Glomerular filtration rate (GFR) is now widely accepted as the best indicator of renal function, and current clinical guidelines advocate its use in the staging of kidney disease. The optimum measure of GFR is by the use of exogenous tracer agents. However current clinically employed agents lack sensitivity or are cumbersome to use. An exogenous GFR fluorescent tracer agent, whose elimination rate could be monitored noninvasively through skin would provide a substantial improvement over currently available methods. We developed a series of novel aminopyrazine analogs for use as exogenous fluorescent GFR tracer agents that emit light in the visible region for monitoring GFR noninvasively over skin. In rats, these compounds are eliminated by the kidney with urine recovery greater than 90% of injected dose, are not broken down or metabolized in vivo, are not secreted by the renal tubules, and have clearance values similar to a GFR reference compound, iothalamate. In addition, biological half-life of these compounds measured in rats by noninvasive optical methods correlated with plasma derived methods. In this study, we show that this noninvasive methodology with our novel fluorescent tracer agents can detect impaired renal function. A 5/6th nephrectomy rat model is employed.
NASA Astrophysics Data System (ADS)
Starikova, M. K.; Bulanova, A. A.; Bukreeva, E. B.; Karapuzikov, A. A.; Karapuzikov, A. I.; Kistenev, Y. V.; Klementyev, V. M.; Kolker, D. B.; Kuzmin, D. A.; Nikiforova, O. Y.; Ponomarev, Yu. N.; Sherstov, I. V.; Boyko, A. A.
2013-11-01
Pulmonary diseases diagnostics always occupies one of the key positions in medicine practices. A large variety of high technology methods are used today, but none of them cannot be used for early screening of pulmonary diseases. We discuss abilities of methods of IR and terahertz laser spectroscopy for noninvasive express diagnostics of pulmonary diseases on a base of analysis of absorption spectra of patient's gas emission, in particular, exhaled air. Experience in the field of approaches to experimental data analysis and hard-ware realization of gas analyzers for medical applications is also discussed.
Chang, K.; Barnes, S.; Haacke, E.M.; Grossman, R.I.; Ge, Y.
2014-01-01
BACKGROUND AND PURPOSE Cerebrovascular oxygenation changes during respiratory challenges have clinically important implications for brain function, including cerebral autoregulation and the rate of brain metabolism. SWI is sensitive to venous oxygenation level by exploitation of the magnetic susceptibility of deoxygenated blood. We assessed cerebral venous blood oxygenation changes during simple voluntary breath-holding (apnea) and hyperventilation by use of SWI at 3T. MATERIALS AND METHODS We performed SWI scans (3T; acquisition time of 1 minute, 28 seconds; centered on the anterior commissure and the posterior commissure) on 10 healthy male volunteers during baseline breathing as well as during simple voluntary hyperventilation and apnea challenges. The hyperventilation and apnea tasks were separated by a 5-minute resting period. SWI venograms were generated, and the signal changes on SWI before and after the respiratory stress tasks were compared by means of a paired Student t test. RESULTS Changes in venous vasculature visibility caused by the respiratory challenges were directly visualized on the SWI venograms. The venogram segmentation results showed that voluntary apnea decreased the mean venous blood voxel number by 1.6% (P<.0001), and hyperventilation increased the mean venous blood voxel number by 2.7% (P<.0001). These results can be explained by blood CO2 changes secondary to the respiratory challenges, which can alter cerebrovascular tone and cerebral blood flow and ultimately affect venous oxygen levels. CONCLUSIONS These results highlight the sensitivity of SWI to simple and noninvasive respiratory challenges and its potential utility in assessing cerebral hemodynamics and vasomotor responses. PMID:24371029
Intercomparison of techniques for the non-invasive measurement of bone mass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohn, S.H.
1981-01-01
A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques.
The clinical diagnosis of splenomegaly.
Yang, J. C.; Rickman, L. S.; Bosser, S. K.
1991-01-01
Assessing for the presence of splenomegaly is an important component of the physical examination. Although several methods of palpation and percussion of the spleen have been described, until recently they have not been validated by noninvasive imaging techniques such as ultrasonography, radionuclide scanning, and computed tomography that offer objective means to assess splenomegaly. We review the literature comparing various physical examination techniques with noninvasive imaging modalities and conclude that palpation and percussion of the spleen are complementary but frequently insensitive and that further studies are needed to evaluate the efficacy of specific diagnostic methods. PMID:1877230
2011-01-01
Background For brain computer interfaces (BCIs), which may be valuable in neurorehabilitation, brain signals derived from mental activation can be monitored by non-invasive methods, such as functional near-infrared spectroscopy (fNIRS). Single-trial classification is important for this purpose and this was the aim of the presented study. In particular, we aimed to investigate a combined approach: 1) offline single-trial classification of brain signals derived from a novel wireless fNIRS instrument; 2) to use motor imagery (MI) as mental task thereby discriminating between MI signals in response to different tasks complexities, i.e. simple and complex MI tasks. Methods 12 subjects were asked to imagine either a simple finger-tapping task using their right thumb or a complex sequential finger-tapping task using all fingers of their right hand. fNIRS was recorded over secondary motor areas of the contralateral hemisphere. Using Fisher's linear discriminant analysis (FLDA) and cross validation, we selected for each subject a best-performing feature combination consisting of 1) one out of three channel, 2) an analysis time interval ranging from 5-15 s after stimulation onset and 3) up to four Δ[O2Hb] signal features (Δ[O2Hb] mean signal amplitudes, variance, skewness and kurtosis). Results The results of our single-trial classification showed that using the simple combination set of channels, time intervals and up to four Δ[O2Hb] signal features comprising Δ[O2Hb] mean signal amplitudes, variance, skewness and kurtosis, it was possible to discriminate single-trials of MI tasks differing in complexity, i.e. simple versus complex tasks (inter-task paired t-test p ≤ 0.001), over secondary motor areas with an average classification accuracy of 81%. Conclusions Although the classification accuracies look promising they are nevertheless subject of considerable subject-to-subject variability. In the discussion we address each of these aspects, their limitations for future approaches in single-trial classification and their relevance for neurorehabilitation. PMID:21682906
Konieczna, Lucyna; Pyszka, Magdalena; Okońska, Magdalena; Niedźwiecki, Maciej; Bączek, Tomasz
2018-03-23
Exhaled breath condensate (EBC) is receiving increased attention as a novel, entirely non-invasive technique for collecting biomarker samples. This increased attention is due to the fact that EBC is simple, effort independent, rapid, can be repeated frequently, and can be performed on young children and patients suffering from a variety of diseases. By having a subject breathe tidally through a cooling system for 15-20 min, a sufficient amount of condensate is collected for analysis of biomarkers in clinical studies. However, bioanalysis of EBC involves an unavoidable sample preparation step due to the low concentration of its components. Thus, there is a need for a new and more sensitive analytical method of assessing EBC samples. While researchers have considered analyses of single and small quantities of amino acids - for example, those connected with leukemia - no one has previously attempted to simultaneously analyze a panel of 23 amino acids. Moreover, the present study is well-justified, as prior studies focusing on single amino acids and leukemia at the moment of diagnosis and during chemotherapy (33 days of treatment) are inconsistent. In the present study, amino acids were separated using an XBridge Amide column (3 mm × 100 mm, 3.5 μm). The mobile phase consisted of 10 mM of ammonium buffer in water with a pH of 3 (Phase A) and 10 mM ammonium buffer in acetonitrile (Phase B) under gradient program elution. The analytes were detected in electrospray positive ionization mode. Under optimal conditions, the proposed method exhibited limits of quantification (LOQ) in the range of 0.05-0.5 ng/mL, and good linearity, with the determination coefficient (R 2 ) falling between 0.9904 and 0.9998. The accuracy in human exhaled breath condensate samples ranged between 93.3-113.3% for the 23 studied amino acids, with intra- and inter-day coefficient of variation (CVs) of 0.13-9.92% and 0.17-10.53%, respectively. To demonstrate the liquid chromatography with hydrophilic interaction with electrospray source coupled to tandem mass spectrometry (LC-HILIC-ESI-MS/MS) method's applicability for biomedical investigations, it was verified and applied to determine amino acids in pediatric patients with leukemia. These tests confirmed that glutamine, arginine, homoarginine, asparagine, histidine, methionine, proline, hydroxyproline, threonine, tyrosine, and valine were present in significantly higher levels in pediatric leukemia patients than in the healthy control group. The developed assay is an attractive alternative to standard analytical methods, because it allows for the non-invasive, fast, sensitive, and reliable analysis of amino acids without derivatization in EBC. Copyright © 2018 Elsevier B.V. All rights reserved.
Noninvasive diagnostic devices for diabetes through measuring tear glucose.
Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin
2011-01-01
This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4-5 times a day to check blood glucose levels--almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. © 2010 Diabetes Technology Society.
Rao, Rohit P; Danduran, Michael J; Loomba, Rohit S; Dixon, Jennifer E; Hoffman, George M
2012-06-01
Cardiopulmonary exercise testing (CPET) provides assessment of the integrative responses involving the pulmonary, cardiovascular, and skeletal muscle systems. Application of exercise testing remains limited to children who are able to understand and cooperate with the exercise protocol. Near-infrared spectroscopy (NIRS) provides a noninvasive, continuous method to monitor regional tissue oxygenation (rSO2). Our specific aim was to predict anaerobic threshold (AT) during CPET noninvasively using two-site NIRS monitoring. Achievement of a practical noninvasive technology for estimating AT will increase the compatibility of CPET. Patients without structural or acquired heart disease were eligible for inclusion if they were ordered to undergo CPET by a cardiologist. Data from 51 subjects was analyzed. The ventilatory anaerobic threshold (VAT) was computed on [Formula: see text] and respiratory quotient post hoc using the standard V-slope method. The inflection points of the regional rSO2 time-series were identified as the noninvasive regional NIRS AT for each of the two monitored regions (cerebral and kidney). AT calculation made using an average of kidney and brain NIRS matched the calculation made by VAT for the same patient. Two-site NIRS monitoring of visceral organs is a predictor of AT.
Warmerdam, G; Vullings, R; Van Pul, C; Andriessen, P; Oei, S G; Wijn, P
2013-01-01
Non-invasive fetal electrocardiography (ECG) can be used for prolonged monitoring of the fetal heart rate (FHR). However, the signal-to-noise-ratio (SNR) of non-invasive ECG recordings is often insufficient for reliable detection of the FHR. To overcome this problem, source separation techniques can be used to enhance the fetal ECG. This study uses a physiology-based source separation (PBSS) technique that has already been demonstrated to outperform widely used blind source separation techniques. Despite the relatively good performance of PBSS in enhancing the fetal ECG, PBSS is still susceptible to artifacts. In this study an augmented PBSS technique is developed to reduce the influence of artifacts. The performance of the developed method is compared to PBSS on multi-channel non-invasive fetal ECG recordings. Based on this comparison, the developed method is shown to outperform PBSS for the enhancement of the fetal ECG.
Kreiner-Møller, A; Stracke, F; Zimmermann, H
2013-01-01
Various cryoprotective agents (CPA) are added to cell media in order to avoid cell injury during cryo preservation. The resulting complex environment of the preserved cell, consisting of crystalline and liquid phases can however not be investigated non-invasively by established methods in cryobiology. This study shows how scanning confocal Raman microscopy can non-invasively extract information on chemical composition, phase domain and distribution at cryogenic temperatures. The formation of the salt hydrate, hydrohalite NaCl∙H2O, in solutions comprised of phosphate buffered saline (PBS) and dimethyl sulphoxide (DMSO) is studied in particular. Scanning confocal Raman microscopy can be used to unambiguously identify hydrohalite in a medium containing DMSO and saline. The confocal Raman microscopy imaging along with differential scanning calorimetric measurements further show that the hydrohalite is formed without eutectic formation. This method also allows for discrimination between closely packed hydrohalite crystals that are oriented differently.
Greene, Jacob; Louis, Julien; Korostynska, Olga; Mason, Alex
2017-02-23
Muscle glycogen levels have a profound impact on an athlete's sporting performance, thus measurement is vital. Carbohydrate manipulation is a fundamental component in an athlete's lifestyle and is a critical part of elite performance, since it can provide necessary training adaptations. This paper provides a critical review of the current invasive and non-invasive methods for measuring skeletal muscle glycogen levels. These include the gold standard muscle biopsy, histochemical analysis, magnetic resonance spectroscopy, and musculoskeletal high frequency ultrasound, as well as pursuing future application of electromagnetic sensors in the pursuit of portable non-invasive quantification of muscle glycogen. This paper will be of interest to researchers who wish to understand the current and most appropriate techniques in measuring skeletal muscle glycogen. This will have applications both in the lab and in the field by improving the accuracy of research protocols and following the physiological adaptations to exercise.
Recent advances in the noninvasive strategies of cardiac amyloidosis.
Zhao, Lei; Fang, Quan
2016-11-01
The heart, like any organ in the body, is susceptible to amyloid deposition. Although more than 30 types of protein can cause amyloidosis, only two types commonly deposit in the ventricular myocardium: amyloid light chain and amyloid transthyretin. Amyloid cardiomyopathy is usually a major determinant of patient outcomes, and the diagnosis of heart involvement can be often relatively under-diagnosed, owing to nonspecific presenting symptoms and signs at a subclinical stage. The diagnosis of cardiac amyloidosis is usually performed by endomyocardial biopsy; however, the invasive nature and related high-risk complications restrict its wide use in clinical settings. Recently, with the advent of innovative techniques used for evaluating cardiac amyloidosis, noninvasive methods become increasingly important, especially in earlier diagnosis, distinguishing typing, risk prediction and response to treatment. Here, we will review recent developments in the noninvasive methods used in the assessment of cardiac amyloidosis, focused on the laboratory biomarkers and imaging modalities.
NASA Astrophysics Data System (ADS)
Shera, Christopher A.
Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics-termed "tapering symmetry" after its geometric interpretation in simple models-that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical inhomogeneities responsible for evoked emission. Although current models require that the periodicities found in emission spectra and threshold hearing curves originate in a corresponding corrugation in the mechanics of the cochlea, it is shown that the observed spectral periodicities can arise spontaneously through the dynamics of wave propagation and reflection and that the organ of Corti, as suggested by the anatomy, need manifest no particular translational symmetries.
NASA Astrophysics Data System (ADS)
Shera, Christopher Alan
Otoacoustic emissions demonstrate that the ear creates sound while listening to sound, offering a promising acoustic window on the mechanics of hearing in awake, listening human beings. That window is clouded, however, by an incomplete knowledge of wave reflection and transmission, both forth and back within the cochlea and through the middle ear. This thesis "does windows," addressing wave propagation and scattering on both sides of the middle ear. A summary of highlights follows. Measurements of the cochlear input impedance in cat are used to identify a new symmetry in cochlear mechanics--termed "tapering symmetry" after its geometric interpretation in simple models--that guarantees that the wavelength of the traveling wave changes slowly with position near the stapes. Waves therefore propagate without reflection through the basal turns of the cochlea. Analytic methods for solving the cochlear wave equations using a perturbative scattering series are given and used to demonstrate that, contrary to common belief, conventional cochlear models exhibit negligible internal reflection whether or not they accurately represent the tapering symmetries of the inner ear. Frameworks for the systematic "deconstruction" of eardrum and middle-ear transduction characteristics are developed and applied to the analysis of noninvasive measurements of middle-ear and cochlear mechanics. A simple phenomenological model of inner-ear compressibility that correctly predicts hearing thresholds in patients with missing or disarticulated middle-ear ossicles is developed and used to establish an upper bound on cochlear compressibility several orders of magnitude smaller than that provided by direct measurements. Accurate measurements of stimulus -frequency evoked otoacoustic emissions are performed and used to determine the form and frequency variation of the cochlear traveling-wave ratio noninvasively. Those measurements are inverted to obtain the spatial distribution of mechanical inhomogeneities responsible for evoked emission. Although current models require that the periodicities found in emission spectra and threshold hearing curves originate in a corresponding corrugation in the mechanics of the cochlea, it is shown that the observed spectral periodicities can arise spontaneously through the dynamics of wave propagation and reflection and that the organ of Corti, as suggested by the anatomy, need manifest no particular translational symmetries.
Zhang, Yong; Zhang, Nan; Zhao, Ming; Hoffman, Robert M
2015-07-01
Orthotopic implantation of cancer allows metastasis to occur. The most patient-like metastatic orthotopic models are developed with surgical orthotopic implantation using intact tissue in order to preserve the natural tissue structure of the tumor which contains both cancer cells and stroma. In the present study, we performed a simple thoracotomy by making an intercostal incision between the fourth and fifth ribs on the left side of the chest of nude mice. Lung tumor fragments expressing red fluorescent protein were then implanted on the left lung. It was possible to monitor tumor formation in the lung non-invasively by spectral imaging using the Maestro system with a liquid tunable filter. The model described here has high tumorigenicity in the lung (100%) and a low mortality rate (5%). This imageable nude mouse model using surgical orthotopic implantation of lung cancer will be useful for all types of longitudinal studies. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Xu, Huang-Wei; Hsu, Yung-Chien; Chang, Chia-Hao; Wei, Kuo-Liang; Lin, Chun-Liang
2016-03-01
Growing evidence suggests that non-alcoholic fatty liver disease (NAFLD) is linked to an increased risk for chronic kidney disease (CKD); liver fibrosis with biopsy-proven NAFLD has also been shown to associate with an increased risk of CKD. This study compares the diagnostic performance of simple noninvasive tests in identifying prevalent CKD among individuals with ultrasonography-diagnosed NAFLD. A total of 755 with ultrasonography-diagnosed NAFLD were included. Estimated glomerular filtration rate and noninvasive markers for hepatic fibrosis: aspartate transaminase to alanine transaminase ratio (AAR), aspartate transaminase to platelet ratio index (APRI), FIB-4 score, NAFLD fibrosis score (NFS) and BARD score were assessed. Binary logistic regression to generate a propensity score and receiver operating characteristic curves were developed for each of the noninvasive markers for predicting CKD, and the area under the receiver operating characteristic curve was greatest for FIB-4 score (0.750), followed by NFS (0.710), AAR (0.594), APRI (0.587), and BARD score (0.561). A cut-off value of 1.100 for FIB-4 score gave a sensitivity of 68.85% and a specificity of 71.07% for predicting CKD. The positive predictive value and negative predictive value were 37.50 and 90.05%, respectively. In multiple logistic regression analysis, only FIB-4 score ≧1.100 (OR 2.660, 95% CI 1.201-5.889; p = .016), older age, higher diastolic blood pressure and higher uric acid were independent predictors of CKD. High noninvasive fibrosis score is associated with an increased risk of prevalent CKD; the FIB-4 is the better predictor. With a cut-off value of 1.100 for FIB-4, it is useful in excluding the presence of CKD in patients with NAFLD.
Application of optical lens of a CD writer for detecting the blood glucose semi-invasively
NASA Astrophysics Data System (ADS)
Meshram, N. D.; Dahikar, P. B.
2014-10-01
Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..
Noninvasive differential diagnosis of dental periapical lesions in cone-beam CT scans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Okada, Kazunori, E-mail: kazokada@sfsu.edu; Rysavy, Steven; Flores, Arturo
Purpose: This paper proposes a novel application of computer-aided diagnosis (CAD) to an everyday clinical dental challenge: the noninvasive differential diagnosis of periapical lesions between periapical cysts and granulomas. A histological biopsy is the most reliable method currently available for this differential diagnosis; however, this invasive procedure prevents the lesions from healing noninvasively despite a report that they may heal without surgical treatment. A CAD using cone-beam computed tomography (CBCT) offers an alternative noninvasive diagnostic tool which helps to avoid potentially unnecessary surgery and to investigate the unknown healing process and rate for the lesions. Methods: The proposed semiautomatic solutionmore » combines graph-based random walks segmentation with machine learning-based boosted classifiers and offers a robust clinical tool with minimal user interaction. As part of this CAD framework, the authors provide two novel technical contributions: (1) probabilistic extension of the random walks segmentation with likelihood ratio test and (2) LDA-AdaBoost: a new integration of weighted linear discriminant analysis to AdaBoost. Results: A dataset of 28 CBCT scans is used to validate the approach and compare it with other popular segmentation and classification methods. The results show the effectiveness of the proposed method with 94.1% correct classification rate and an improvement of the performance by comparison with the Simon’s state-of-the-art method by 17.6%. The authors also compare classification performances with two independent ground-truth sets from the histopathology and CBCT diagnoses provided by endodontic experts. Conclusions: Experimental results of the authors show that the proposed CAD system behaves in clearer agreement with the CBCT ground-truth than with histopathology, supporting the Simon’s conjecture that CBCT diagnosis can be as accurate as histopathology for differentiating the periapical lesions.« less
NASA Astrophysics Data System (ADS)
Hallacoglu, Bertan; Sassaroli, Angelo M.; Rosenberg, Irwin H.; Troen, Aron; Fantini, Sergio
2011-02-01
Structural abnormalities in brain microvasculature are commonly associated with Alzheimer's Disease and other dementias. However, the extent to which structural microvascular abnormalities cause functional impairments in brain circulation and thereby to cognitive impairment is unclear. Non-invasive, near-infrared spectroscopy (NIRS) methods can be used to determine the absolute hemoglobin concentration and saturation in brain tissue, from which additional parameters such as cerebral blood volume (a theoretical correlate of brain microvascular density) can be derived. Validating such NIRS parameters in animal models, and understanding their relationship to cognitive function is an important step in the ultimate application of these methods to humans. To this end we applied a non-invasive multidistance NIRS method to determine the absolute concentration and saturation of cerebral hemoglobin in rat, by separately measuring absorption and reduced scattering coefficients without relying on pre- or post-correction factors. We applied this method to study brain circulation in folate deficient rats, which express brain microvascular pathology1 and which we have shown to develop cognitive impairment.2 We found absolute brain hemoglobin concentration ([HbT]) and oxygen saturation (StO2) to be significantly lower in folate deficient rats (n=6) with respect to control rats (n=5) (for [HbT]: 73+/-10 μM vs. 95+/-14 μM for StO2: 55%+/-7% vs. 66% +/-4%), implicating microvascular pathology and diminished oxygen delivery as a mechanism of cognitive impairment. More generally, our study highlights how noninvasive, absolute NIRS measurements can provide unique insight into the pathophysiology of Vascular Cognitive Impairment. Applying this method to this and other rat models of cognitive impairment will help to validate physiologically meaningful NIRS parameters for the ultimate goal of studying cerebral microvascular disease and cognitive decline in humans.
Non-Invasive Seismic Methods for Earthquake Site Classification Applied to Ontario Bridge Sites
NASA Astrophysics Data System (ADS)
Bilson Darko, A.; Molnar, S.; Sadrekarimi, A.
2017-12-01
How a site responds to earthquake shaking and its corresponding damage is largely influenced by the underlying ground conditions through which it propagates. The effects of site conditions on propagating seismic waves can be predicted from measurements of the shear wave velocity (Vs) of the soil layer(s) and the impedance ratio between bedrock and soil. Currently the seismic design of new buildings and bridges (2015 Canadian building and bridge codes) requires determination of the time-averaged shear-wave velocity of the upper 30 metres (Vs30) of a given site. In this study, two in situ Vs profiling methods; Multichannel Analysis of Surface Waves (MASW) and Ambient Vibration Array (AVA) methods are used to determine Vs30 at chosen bridge sites in Ontario, Canada. Both active-source (MASW) and passive-source (AVA) surface wave methods are used at each bridge site to obtain Rayleigh-wave phase velocities over a wide frequency bandwidth. The dispersion curve is jointly inverted with each site's amplification function (microtremor horizontal-to-vertical spectral ratio) to obtain shear-wave velocity profile(s). We apply our non-invasive testing at three major infrastructure projects, e.g., five bridge sites along the Rt. Hon. Herb Gray Parkway in Windsor, Ontario. Our non-invasive testing is co-located with previous invasive testing, including Standard Penetration Test (SPT), Cone Penetration Test and downhole Vs data. Correlations between SPT blowcount and Vs are developed for the different soil types sampled at our Ontario bridge sites. A robust earthquake site classification procedure (reliable Vs30 estimates) for bridge sites across Ontario is evaluated from available combinations of invasive and non-invasive site characterization methods.
Application of optical lens of a CD writer for detecting the blood glucose semi-invasively
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meshram, N. D., E-mail: meshramnileshsd@gmail.com; Dahikar, P. B., E-mail: pbdahikar@rediffmail.com
Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of bloodmore » sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.« less
Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R
2015-10-01
Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.
Gao, Hengyi; Zhu, Feng; Wang, Min; Zhang, Hang; Ye, Dawei; Yang, Jiayin; Jiang, Li; Liu, Chang; Qin, Renyi; Yan, Lunan; Xiao, Guangqin
2017-01-01
Background Advanced liver fibrosis can result in serious complications (even patient’s death) after partial hepatectomy. Preoperatively percutaneous liver biopsy is an invasive and expensive method to assess liver fibrosis. We aim to establish a noninvasive model, on the basis of preoperative biomarkers, to predict liver fibrosis in hepatocellular carcinoma (HCC) patients with hepatitis B virus (HBV) infection. Methods The HBV-infected liver cancer patients who had received hepatectomy were retrospectively and prospectively enrolled in this study. Univariate analysis was used to compare the variables of the patients with mild to moderate liver fibrosis and with severe liver fibrosis. The significant factors were selected into binary logistic regression analysis. Factors determined to be significant were used to establish a noninvasive model. Then the diagnostic accuracy of this novel model was examined based on sensitivity, specificity and area under the receiver-operating characteristic curve (AUC). Results This study included 2,176 HBV-infected HCC patients who had undergone partial hepatectomy (1,682 retrospective subjects and 494 prospective subjects). Regression analysis indicated that total bilirubin and prothrombin time had positive correlation with liver fibrosis. It also demonstrated that blood platelet count and fibrinogen had negative correlation with liver fibrosis. The AUC values of the model based on these four factors for predicting significant fibrosis, advanced fibrosis and cirrhosis were 0.79-0.83, 0.83-0.85 and 0.85-0.88, respectively. Conclusion The results showed that this novel preoperative model was an excellent noninvasive method for assessing liver fibrosis in HBV-infected HCC patients. PMID:28008144
Electrical bioimpedance and other techniques for gastric emptying and motility evaluation
Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Flores-Hernández, Corina; Morales-Mata, Ismael
2012-01-01
The aim of this article is to identify non-invasive, inexpensive, highly sensitive and accurate techniques for evaluating and diagnosing gastric diseases. In the case of the stomach, there are highly sensitive and specific methods for assessing gastric motility and emptying (GME). However, these methods are invasive, expensive and/or not technically feasible for all clinicians and patients. We present a summary of the most relevant international information on non-invasive methods and techniques for clinically evaluating GME. We particularly emphasize the potential of gastric electrical bioimpedance (EBI). EBI was initially used mainly in gastric emptying studies and was essentially abandoned in favor of techniques such as electrogastrography and the gold standard, scintigraphy. The current research evaluating the utility of gastric EBI either combines this technique with other frequently used techniques or uses new methods for gastric EBI signal analysis. In this context, we discuss our results and those of other researchers who have worked with gastric EBI. In this review article, we present the following topics: (1) a description of the oldest methods and procedures for evaluating GME; (2) an explanation of the methods currently used to evaluate gastric activity; and (3) a perspective on the newest trends and techniques in clinical and research GME methods. We conclude that gastric EBI is a highly effective non-invasive, easy to use and inexpensive technique for assessing GME. PMID:22368782
Why minimally invasive skin sampling techniques? A bright scientific future.
Wang, Christina Y; Maibach, Howard I
2011-03-01
There is increasing interest in minimally invasive skin sampling techniques to assay markers of molecular biology and biochemical processes. This overview examines methodology strengths and limitations, and exciting developments pending in the scientific community. Publications were searched via PubMed, the U.S. Patent and Trademark Office Website, the DermTech Website and the CuDerm Website. The keywords used were noninvasive skin sampling, skin stripping, skin taping, detergent method, ring method, mechanical scrub, reverse iontophoresis, glucose monitoring, buccal smear, hair root sampling, mRNA, DNA, RNA, and amino acid. There is strong interest in finding methods to access internal biochemical, molecular, and genetic processes through noninvasive and minimally invasive external means. Minimally invasive techniques include the widely used skin tape stripping, the abrasion method that includes scraping and detergent, and reverse iontophoresis. The first 2 methods harvest largely the stratum corneum. Hair root sampling (material deeper than the epidermis), buccal smear, shave biopsy, punch biopsy, and suction blistering are also methods used to obtain cellular material for analysis, but involve some degree of increased invasiveness and thus are only briefly mentioned. Existing and new sampling methods are being refined and validated, offering exciting, different noninvasive means of quickly and efficiently obtaining molecular material with which to monitor bodily functions and responses, assess drug levels, and follow disease processes without subjecting patients to unnecessary discomfort and risk.
Anesthesia Methods in Laser Resurfacing
Gaitan, Sergio; Markus, Ramsey
2012-01-01
Laser resurfacing technology offers the ability to treat skin changes that are the result of the aging process. One of the major drawbacks of laser resurfacing technologies is the pain associated with the procedure. The methods of anesthesia used in laser resurfacing to help minimize the pain include both noninvasive and invasive procedures. The noninvasive procedures can be divided into topical, cryoanesthesia, and a combination of both. The invasive methods of anesthesia include injected forms (infiltrative, nerve blocks, and tumescent anesthesia) and supervised anesthesia (monitored anesthesia care and general anesthesia). In this review, the authors summarize the types of anesthesia used in laser resurfacing to aid the provider in offering the most appropriate method for the patient to have as painless a procedure as possible. PMID:23904819
Optical methods for noninvasive determination of carotenoids in human and animal skin
NASA Astrophysics Data System (ADS)
Darvin, Maxim E.; Meinke, Martina C.; Sterry, Wolfram; Lademann, Juergen
2013-06-01
Carotenoids are important substances for human skin due to their powerful antioxidant properties in reaction of neutralization of free radicals and especially reactive oxygen species, including singlet oxygen. Concentration of carotenoids in the skin could mirror the current redox status of the skin and should be investigated in vivo. Optical methods are ideally suited for determination of carotenoids in mammalian skin in vivo as they are both noninvasive and quick. Four different optical methods could be used for in vivo measurement of carotenoids in the human or animal skin: (1) resonance Raman spectroscopy; (2) Raman microscopy; (3) reflection spectroscopy; (4) skin color measurements. The advantages, shortcomings, and limitations of the above-mentioned optical methods are discussed.
Optical methods for noninvasive determination of carotenoids in human and animal skin.
Darvin, Maxim E; Meinke, Martina C; Sterry, Wolfram; Lademann, Juergen
2013-06-01
Carotenoids are important substances for human skin due to their powerful antioxidant properties in reaction of neutralization of free radicals and especially reactive oxygen species, including singlet oxygen. Concentration of carotenoids in the skin could mirror the current redox status of the skin and should be investigated in vivo. Optical methods are ideally suited for determination of carotenoids in mammalian skin in vivo as they are both noninvasive and quick. Four different optical methods could be used for in vivo measurement of carotenoids in the human or animal skin: (1) resonance Raman spectroscopy; (2) Raman microscopy; (3) reflection spectroscopy; (4) skin color measurements. The advantages, shortcomings, and limitations of the above-mentioned optical methods are discussed.
Noninvasive analysis of microbiome dynamics in the fruit fly Drosophila melanogaster.
Fink, Christine; Staubach, Fabian; Kuenzel, Sven; Baines, John F; Roeder, Thomas
2013-11-01
The diversity and structure of the intestinal microbial community has a strong influence on life history. To understand how hosts and microbes interact, model organisms with comparatively simple microbial communities, such as the fruit fly (Drosophila melanogaster), offer key advantages. However, studies of the Drosophila microbiome are limited to a single point in time, because flies are typically sacrificed for DNA extraction. In order to test whether noninvasive approaches, such as sampling of fly feces, could be a means to assess fly-associated communities over time on the same cohort of flies, we compared the microbial communities of fly feces, dissected fly intestines, and whole flies across three different Drosophila strains. Bacterial species identified in either whole flies or isolated intestines were reproducibly found in feces samples. Although the bacterial communities of feces and intestinal samples were not identical, they shared similarities and obviously the same origin. In contrast to material from whole flies and intestines, feces samples were not compromised by Wolbachia spp. infections, which are widespread in laboratory and wild strains. In a proof-of-principle experiment, we showed that simple nutritional interventions, such as a high-fat diet or short-term starvation, had drastic and long-lasting effects on the micobiome. Thus, the analysis of feces can supplement the toolbox for microbiome studies in Drosophila, unleashing the full potential of such studies in time course experiments where multiple samples from single populations are obtained during aging, development, or experimental manipulations.
Noninvasive Hemodynamic Measurements During Neurosurgical Procedures in Sitting Position.
Schramm, Patrick; Tzanova, Irene; Gööck, Tilman; Hagen, Frank; Schmidtmann, Irene; Engelhard, Kristin; Pestel, Gunther
2017-07-01
Neurosurgical procedures in sitting position need advanced cardiovascular monitoring. Transesophageal echocardiography (TEE) to measure cardiac output (CO)/cardiac index (CI) and stroke volume (SV), and invasive arterial blood pressure measurements for systolic (ABPsys), diastolic (ABPdiast) and mean arterial pressure (MAP) are established monitoring technologies for these kind of procedures. A noninvasive device for continuous monitoring of blood pressure and CO based on a modified Penaz technique (volume-clamp method) was introduced recently. In the present study the noninvasive blood pressure measurements were compared with invasive arterial blood pressure monitoring, and the noninvasive CO monitoring to TEE measurements. Measurements of blood pressure and CO were performed in 35 patients before/after giving a fluid bolus and a change from supine to sitting position, start of surgery, and repositioning from sitting to supine at the end of surgery. Data pairs from the noninvasive device (Nexfin HD) versus arterial line measurements (ABPsys, ABPdiast, MAP) and versus TEE (CO, CI, SV) were compared using Bland-Altman analysis and percentage error. All parameters compared (CO, CI, SV, ABPsys, ABPdiast, MAP) showed a large bias and wide limits of agreement. Percentage error was above 30% for all parameters except ABPsys. The noninvasive device based on a modified Penaz technique cannot replace arterial blood pressure monitoring or TEE in anesthetized patients undergoing neurosurgery in sitting position.
NASA Astrophysics Data System (ADS)
Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.
2003-07-01
The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.
British Thoracic Society Quality Standards for acute non-invasive ventilation in adults
Davies, Michael; Allen, Martin; Bentley, Andrew; Bourke, Stephen C; Creagh-Brown, Ben; D’Oliveiro, Rachel; Glossop, Alastair; Gray, Alasdair; Jacobs, Phillip; Mahadeva, Ravi; Moses, Rachael; Setchfield, Ian
2018-01-01
Introduction The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for the provision of acute non-invasive ventilation in adults together with measurable markers of good practice. Methods Development of British Thoracic Society (BTS) Quality Standards follows the BTS process of quality standard production based on the National Institute for Health and Care Excellence process manual for the development of quality standards. Results 6 quality statements have been developed, each describing a standard of care for the provision of acute non-invasive ventilation in the UK, together with measurable markers of good practice. Conclusion BTS Quality Standards for acute non-invasive ventilation in adults form a key part of the range of supporting materials that the Society produces to assist in the dissemination and implementation of guideline’s recommendations. PMID:29636979
NASA Astrophysics Data System (ADS)
Talukder, Ashit; Morookian, John M.; Monacos, Steve P.; Lam, Raymond K.; Lebaw, C.; Bond, A.
2004-04-01
Eyetracking is one of the latest technologies that has shown potential in several areas including human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological problems in individuals. Current non-invasive eyetracking methods achieve a 30 Hz rate with possibly low accuracy in gaze estimation, that is insufficient for many applications. We propose a new non-invasive visual eyetracking system that is capable of operating at speeds as high as 6-12 KHz. A new CCD video camera and hardware architecture is used, and a novel fast image processing algorithm leverages specific features of the input CCD camera to yield a real-time eyetracking system. A field programmable gate array (FPGA) is used to control the CCD camera and execute the image processing operations. Initial results show the excellent performance of our system under severe head motion and low contrast conditions.
You, Yanqin; Sun, Yan; Li, Xuchao; Li, Yali; Wei, Xiaoming; Chen, Fang; Ge, Huijuan; Lan, Zhangzhang; Zhu, Qian; Tang, Ying; Wang, Shujuan; Gao, Ya; Jiang, Fuman; Song, Jiaping; Shi, Quan; Zhu, Xuan; Mu, Feng; Dong, Wei; Gao, Vince; Jiang, Hui; Yi, Xin; Wang, Wei; Gao, Zhiying
2014-08-01
This article demonstrates a prominent noninvasive prenatal approach to assist the clinical diagnosis of a single-gene disorder disease, maple syrup urine disease, using targeted sequencing knowledge from the affected family. The method reported here combines novel mutant discovery in known genes by targeted massively parallel sequencing with noninvasive prenatal testing. By applying this new strategy, we successfully revealed novel mutations in the gene BCKDHA (Ex2_4dup and c.392A>G) in this Chinese family and developed a prenatal haplotype-assisted approach to noninvasively detect the genotype of the fetus (transmitted from both parents). This is the first report of integration of targeted sequencing and noninvasive prenatal testing into clinical practice. Our study has demonstrated that this massively parallel sequencing-based strategy can potentially be used for single-gene disorder diagnosis in the future.
Berton, Danilo Cortozi; Kalil, Andre C; Cavalcanti, Manuela; Teixeira, Paulo José Zimermann
2008-10-08
Ventilator-associated pneumonia (VAP) is a common infectious disease in intensive care units (ICUs). The best diagnostic approach to resolve this condition remains uncertain. To evaluate whether quantitative cultures of respiratory secretions are effective in reducing mortality in immunocompetent patients with VAP, compared with qualitative cultures. We also considered changes in antibiotic use, length of ICU stay and mechanical ventilation. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2007, issue 4), which contains the Acute Respiratory Infections Group's Specialized Register; MEDLINE (1966 to December 2007); EMBASE (1974 to December 2007); and LILACS (1982 to December 2007). Randomized controlled trials (RCTs) comparing respiratory samples processed quantitatively or qualitatively, obtained by invasive or non-invasive methods from immunocompetent patients with VAP, and which analyzed the impact of these methods on antibiotic use and mortality rates. Two review authors independently reviewed and selected trials from the search results, and assessed studies for suitability, methodology and quality. We analyzed data using Review Manager software. We pooled the included studies to yield the risk ratio (RR) for mortality and antibiotic change with 95% confidence intervals (CI). Of the 3931 references identified from the electronic databases, five RCTs (1367 patients) met the inclusion criteria. Three studies compared invasive methods using quantitative cultures versus non-invasive methods using qualitative cultures, and were used to answer the main objective of this review. The other two studies compared invasive versus non-invasive methods, both using quantitative cultures. All five studies were combined to compare invasive versus non-invasive interventions for diagnosing VAP. The studies that compared quantitative and qualitative cultures (1240 patients) showed no statistically significant differences in mortality rates (RR = 0.91, 95% CI 0.75 to 1.11). The analysis of all five RCTs showed there was no evidence of mortality reduction in the invasive group versus the non-invasive group (RR = 0.93, 95% CI 0.78 to 1.11). There were no significant differences between the interventions with respect to the number of days on mechanical ventilation, length of ICU stay or antibiotic change. There is no evidence that the use of quantitative cultures of respiratory secretions results in reduced mortality, reduced time in ICU and on mechanical ventilation, or higher rates of antibiotic change when compared to qualitative cultures in patients with VAP. Similar results were observed when invasive strategies were compared with non-invasive strategies.
Wild cats of the Sky Islands: a summary of monitoring efforts using noninvasive techniques
Lisa Haynes; Zoe Hackl; Melanie Culver
2005-01-01
A variety of efforts are taking place to detect, inventory, and monitor the wild felids (pumas, bobcats, jaguars, and ocelots) of the Madrean Archipelago. Researchers are using a suite of noninvasive methods, including infrared-triggered photography, DNA analysis of scat and hair (collected from âhair snaresâ), and old-fashioned tracking and sign searches. These...
Nanotechnology: a promising method for oral cancer detection and diagnosis.
Chen, Xiao-Jie; Zhang, Xue-Qiong; Liu, Qi; Zhang, Jing; Zhou, Gang
2018-06-11
Oral cancer is a common and aggressive cancer with high morbidity, mortality, and recurrence rate globally. Early detection is of utmost importance for cancer prevention and disease management. Currently, tissue biopsy remains the gold standard for oral cancer diagnosis, but it is invasive, which may cause patient discomfort. The application of traditional noninvasive methods-such as vital staining, exfoliative cytology, and molecular imaging-is limited by insufficient sensitivity and specificity. Thus, there is an urgent need for exploring noninvasive, highly sensitive, and specific diagnostic techniques. Nano detection systems are known as new emerging noninvasive strategies that bring the detection sensitivity of biomarkers to nano-scale. Moreover, compared to current imaging contrast agents, nanoparticles are more biocompatible, easier to synthesize, and able to target specific surface molecules. Nanoparticles generate localized surface plasmon resonances at near-infrared wavelengths, providing higher image contrast and resolution. Therefore, using nano-based techniques can help clinicians to detect and better monitor diseases during different phases of oral malignancy. Here, we review the progress of nanotechnology-based methods in oral cancer detection and diagnosis.
Li, Junfeng; Wan, Xiaoxia; Bu, Yajing; Li, Chan; Liang, Jinxing; Liu, Qiang
2016-11-01
Noninvasive examination methods of chemical composition and particle size are presented here based on visible spectroscopy to achieve the identification and recording of mineral pigments used on ancient wall paintings. The normalized spectral curve, slope and curvature extracted from visible spectral reflectance are combined with adjustable weighting coefficients to construct the identification feature space, and Euclid distances between spectral reflectance from wall paintings and a reference database are calculated in the feature space as the discriminant criterion to identify the chemical composition of mineral pigments. A parametric relationship between the integral quantity of spectral reflectance and logarithm of mean particle size is established using a quadratic polynomial to accomplish the noninvasive prediction of mineral pigment particle size used on ancient wall paintings. The feasibility of the proposed methods is validated by the in situ nondestructive identification of the wall paintings in the Mogao Grottoes at Dunhuang. Chinese painting styles and historical evolution are then analyzed according to the identification results of 16 different grottoes constructed from the Sixteen Kingdoms to the Yuan Dynasty. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Zhang, Yanjiao; Xu, Junfa; Li, Linfang; Zeng, Qiuyao; Lin, Lin; Guo, Zhouyi; Liu, Zhiming; Xiong, Honglian; Liu, Songhao
2014-09-01
This study aims to present a noninvasive prostate cancer screening methods using serum surface-enhanced Raman scattering (SERS) and support vector machine (SVM) techniques through peripheral blood sample. SERS measurements are performed using serum samples from 93 prostate cancer patients and 68 healthy volunteers by silver nanoparticles. Three types of kernel functions including linear, polynomial, and Gaussian radial basis function (RBF) are employed to build SVM diagnostic models for classifying measured SERS spectra. For comparably evaluating the performance of SVM classification models, the standard multivariate statistic analysis method of principal component analysis (PCA) is also applied to classify the same datasets. The study results show that for the RBF kernel SVM diagnostic model, the diagnostic accuracy of 98.1% is acquired, which is superior to the results of 91.3% obtained from PCA methods. The receiver operating characteristic curve of diagnostic models further confirm above research results. This study demonstrates that label-free serum SERS analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive prostate cancer screening.
Systematic review of noninvasive treatments to arrest dentin non-cavitated caries lesions
de Assunção, Isauremi Vieira; da Costa, Giovanna de Fátima Alves; Borges, Boniek Castillo Dutra
2014-01-01
AIM: To systematically review the literature on the efficacy of noninvasive methods of arresting the progression of non-cavitated occlusal carious lesions in dentin. METHODS: The Medline/PubMed, LILACS, SciELO and Scopus databases were searched to identify relevant publications through to November 2013. Only clinical trials evaluating the ability of noninvasive methods to arrest the progression of occlusal non-cavitated carious lesions in dentin were included. Screening, data extraction and quality assessment were conducted independently and in duplicate. RESULTS: Of 167 citations identified, nine full text articles were screened and five were included in the analysis. All papers reported on occlusal fissure sealing using a self-curing glass ionomer (n = 1) or resin-based (n = 4) sealant. Only the use of resin-based sealant to obliterate occlusal fissures arrested the progression of non-cavitated occlusal carious lesions in dentin. CONCLUSION: Occlusal fissure sealing with a resin-based sealant may arrest the progression of non-cavitated occlusal dentinal caries. Further clinical trials with longer follow-up times should be performed to increase scientific evidence. PMID:24868513
Intraoperative diagnostics and elimination of residual microtumours with plasmonic nanobubbles
NASA Astrophysics Data System (ADS)
Lukianova-Hleb, Ekaterina Y.; Kim, Yoo-Shin; Belatsarkouski, Ihor; Gillenwater, Ann M.; O'Neill, Brian E.; Lapotko, Dmitri O.
2016-06-01
Failure of cancer surgery to intraoperatively detect and eliminate microscopic residual disease (MRD) causes lethal recurrence and metastases, and the removal of important normal tissues causes excessive morbidity. Here, we show that a plasmonic nanobubble (PNB), a non-stationary laser pulse-activated nanoevent, intraoperatively detects and eliminates MRD in the surgical bed. PNBs were generated in vivo in head and neck cancer cells by systemically targeting tumours with gold colloids and locally applying near-infrared, low-energy short laser pulses, and were simultaneously detected with an acoustic probe. In mouse models, between 3 and 30 residual cancer cells and MRD (undetectable with current methods) were non-invasively detected up to 4 mm deep in the surgical bed within 1 ms. In resectable MRD, PNB-guided surgery prevented local recurrence and delivered 100% tumour-free survival. In unresectable MRD, PNB nanosurgery improved survival twofold compared with standard surgery. Our results show that PNB-guided surgery and nanosurgery can rapidly and precisely detect and remove MRD in simple intraoperative procedures.
Coplanar electrode microfluidic chip enabling accurate sheathless impedance cytometry.
De Ninno, Adele; Errico, Vito; Bertani, Francesca Romana; Businaro, Luca; Bisegna, Paolo; Caselli, Federica
2017-03-14
Microfluidic impedance cytometry offers a simple non-invasive method for single-cell analysis. Coplanar electrode chips are especially attractive due to ease of fabrication, yielding miniaturized, reproducible, and ultimately low-cost devices. However, their accuracy is challenged by the dependence of the measured signal on particle trajectory within the interrogation volume, that manifests itself as an error in the estimated particle size, unless any kind of focusing system is used. In this paper, we present an original five-electrode coplanar chip enabling accurate particle sizing without the need for focusing. The chip layout is designed to provide a peculiar signal shape from which a new metric correlating with particle trajectory can be extracted. This metric is exploited to correct the estimated size of polystyrene beads of 5.2, 6 and 7 μm nominal diameter, reaching coefficient of variations lower than the manufacturers' quoted values. The potential impact of the proposed device in the field of life sciences is demonstrated with an application to Saccharomyces cerevisiae yeast.
NASA Astrophysics Data System (ADS)
Lukianova-Hleb, Ekaterina Y.; Kim, Yoo-Shin; Belatsarkouski, Ihar; Hanna, Ehab Y.; Gillenwater, Ann M.; O'Neill, Brian; Lapotko, Dmitri
2016-02-01
Failure of cancer surgery to intraoperatively detect and eliminate microscopic residual disease (MRD) causes lethal recurrence and metastases, whereas removal of important normal tissues causes excessive morbidity. We report plasmonic nanobubble (PNB) surgical technology to intraoperatively detect and eliminate MRD in surgical bed. PNBs were generated in vivo in head and neck cancer cells by systemically targeting tumor with gold colloids and locally-applied near-infrared low energy short laser pulse, and were simultaneously detected with acoustic probe. In mouse models of head and neck squamous cell carcinoma, single cancer cells and MRD (undetectable with standard histological methods) were instantaneously non-invasively detected in solid tissue in surgical bed. In resectable MRD, PNB-guided surgery prevented local recurrence and delivered 100% tumor-free survival. In unresectable MRD, PNB nano-surgery improved survival by two-fold compared to standard surgery. PNB metrics correlated with the tumor recurrence rate. PNB surgical technology precisely detects and immediately eliminates MRD at macro- and micro-scale in a simple and safe intraoperative procedure.
Tong, Feifei; Lian, Yan; Zhou, Huang; Shi, Xiaohong; He, Fengjiao
2014-10-21
A new multichannel series piezoelectric quartz crystal (MSPQC) cell sensor for real time monitoring of living cells in vitro was reported in this paper. The constructed sensor was used successfully to monitor adhesion, spreading, proliferation, and apoptosis of MG63 osteosarcoma cells and investigate the effects of different concentrations of cobalt chloride on MG63 cells. Quantitative real time and dynamic cell analyses data were conducted using the MSPQC cell sensor. Compared with methods such as fluorescence staining and morphology observation by microscopy, the MSPQC cell sensor is noninvasive, label free, simple, cheap, and capable of online monitoring. It can automatically record the growth status of cells and quantitatively evaluate cell proliferation and the apoptotic response to drugs. It will be a valuable detection and analysis tool for the acquisition of cellular level information and is anticipated to have application in the field of cell biology research or cytotoxicity testing in the future.
Diabetic peripheral neuropathy assessment through texture based analysis of corneal nerve images
NASA Astrophysics Data System (ADS)
Silva, Susana F.; Gouveia, Sofia; Gomes, Leonor; Negrão, Luís; João Quadrado, Maria; Domingues, José Paulo; Morgado, António Miguel
2015-05-01
Diabetic peripheral neuropathy (DPN) is one common complication of diabetes. Early diagnosis of DPN often fails due to the non-availability of a simple, reliable, non-invasive method. Several published studies show that corneal confocal microscopy (CCM) can identify small nerve fibre damage and quantify the severity of DPN, using nerve morphometric parameters. Here, we used image texture features, extracted from corneal sub-basal nerve plexus images, obtained in vivo by CCM, to identify DPN patients, using classification techniques. A SVM classifier using image texture features was used to identify (DPN vs. No DPN) DPN patients. The accuracies were 80.6%, when excluding diabetic patients without neuropathy, and 73.5%, when including diabetic patients without diabetic neuropathy jointly with healthy controls. The results suggest that texture analysis might be used as a complementing technique for DPN diagnosis, without requiring nerve segmentation in CCM images. The results also suggest that this technique has enough sensitivity to detect early disorders in the corneal nerves of diabetic patients.
Goal-directed or aimless? EEG differences during the preparation of a reach-and-touch task.
Pereira, Joana; Ofner, Patrick; Muller-Putz, Gernot R
2015-08-01
The natural control of neuroprostheses is currently a challenge in both rehabilitation engineering and brain-computer interfaces (BCIs) research. One of the recurrent problems is to know exactly when to activate such devices. For the execution of the most common activities of daily living, these devices only need to be active when in the presence of a goal. Therefore, we believe that the distinction between the planning of goal-directed and aimless movements, using non-invasive recordings, can be useful for the implementation of a simple and effective activation method for these devices. We investigated whether those differences are detectable during a reach-and-touch task, using electroencephalography (EEG). Event-related potentials and oscillatory activity changes were studied. Our results show that there are statistically significant differences between both types of movement. Combining this information with movement decoding would allow a natural control strategy for BCIs, exclusively relying on the cognitive processes behind movement preparation and execution.
Assessment of upper airway mechanics during sleep.
Farré, Ramon; Montserrat, Josep M; Navajas, Daniel
2008-11-30
Obstructive sleep apnea, which is the most prevalent sleep breathing disorder, is characterized by recurrent episodes of upper airway collapse and reopening. However, the mechanical properties of the upper airway are not directly measured in routine polysomnography because only qualitative sensors (thermistors for flow and thoraco-abdominal bands for pressure) are used. This review focuses on two techniques that quantify upper airway obstruction during sleep. A Starling model of collapsible conduit allows us to interpret the mechanics of the upper airway by means of two parameters: the critical pressure (Pcrit) and the upstream resistance (Rup). A simple technique to measure Pcrit and Rup involves the application of different levels of continuous positive airway pressure (CPAP) during sleep. The forced oscillation technique is another non-invasive procedure for quantifying upper airway impedance during the breathing cycle in sleep studies. The latest developments in these two methods allow them to be easily applied on a routine basis in order to more fully characterize upper airway mechanics in patients with sleep breathing disorders.
AIDS-related Kaposi sarcoma: findings on thallium-201 scintigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, V.W.; Rosen, M.P.; Baum, A.
1988-12-01
No simple, noninvasive method is available for evaluating extracutaneous Kaposi sarcoma in AIDS patients or for following the tumor's response to treatment. We report our preliminary experience with thallium-201 scintigraphy in nine AIDS patients with proved Kaposi sarcoma. Eight of the nine had abnormal uptake of the radionuclide in skin, lymph nodes, oral cavity, vagina, and lungs. Only four of the nine had cutaneous Kaposi sarcoma at the time of scanning. All cutaneous and mucosal lesions were thallium avid. Two of the six patients with thallium-avid nodes underwent nodal biopsy. Both biopsies confirmed the diagnosis of Kaposi sarcoma. Cutaneous Kaposimore » sarcoma developed later in one of these patients, showing the efficacy of thallium scintigraphy for the early detection of extracutaneous lesions. These preliminary results show thallium avidity in Kaposi sarcoma involving the skin and various extracutaneous sites (lymph nodes, lung, mucosa, and vagina). Thallium scintigraphy is a potentially useful procedure for detecting extracutaneous Kaposi sarcoma in AIDS patients.« less
Detection of single bacteria - causative agents of meningitis using raman microscopy
NASA Astrophysics Data System (ADS)
Baikova, T. V.; Minaeva, S. A.; Sundukov, A. V.; Svistunova, T. S.; Bagratashvili, V. N.; Alushin, M. V.; Gonchukov, S. A.
2015-03-01
Early diagnostics of meningitis is a very topical problem as it is a fulminant disease with a high level of mortality. The progress of this disease is, as a rule, accompanied by the appearance of bacteria in the cerebrospinal fluid (CSF) composition. The examination of the CSF is well known to be the only reliable approach to the identification of meningitis. However, the traditional biochemical analyses are time consuming and not always reliable, simple, and inexpensive, whereas the optical methods are poorly developed. This work is devoted to the study of Raman spectra of several bacterial cultures which are mainly present during meningitis. Raman microscopy is a prompt and noninvasive technique capable of providing reliable information about molecular-level alterations of biological objects at their minimal quantity and size. It was shown that there are characteristic lines in Raman spectra which can be the reliable markers for determination of bacterial form of meningitis at a level of a single bacterium.
Ventilator associated pneumonia: risk factors and preventive measures.
Vincent, J L; Lobo, S; Struelens, M
2001-11-01
Ventilator-associated pneumonia (VAP) is a common nosocomial infection associated with considerable morbidity and mortality. Various risk factors for VAP have been identified and include the duration of ICU stay and of mechanical ventilation, a diagnosis of trauma, and severity of illness. Knowledge of these factors can promote early diagnosis and hence treatment. In addition to simple, but very effective, basic hygiene, different preventative strategies have been suggested, and can be divided into those that aim to limit airway colonization, and those that improve host defense mechanisms. Of the former, non-invasive ventilation is effective but not always applicable or available, nursing the patient in the semi-recumbent position is also associated with a reduced incidence of VAP but carries its own problems, stress ulcer prophylaxis remains controversial, and selective digestive decontamination is probably only relevant to certain subgroups of patients. Methods to improve host defense include early nutrition. Immunostimulatory therapies, such as interferon and granulocyte colony stimulating factor, require further research to confirm their place in the prevention or management of VAP.
Pinto, Francisco; Mielewczik, Michael; Liebisch, Frank; Walter, Achim; Greven, Hartmut; Rascher, Uwe
2013-01-01
Most spectral data for the amphibian integument are limited to the visible spectrum of light and have been collected using point measurements with low spatial resolution. In the present study a dual camera setup consisting of two push broom hyperspectral imaging systems was employed, which produces reflectance images between 400 and 2500 nm with high spectral and spatial resolution and a high dynamic range. We briefly introduce the system and document the high efficiency of this technique analyzing exemplarily the spectral reflectivity of the integument of three arboreal anuran species (Litoria caerulea, Agalychnis callidryas and Hyla arborea), all of which appear green to the human eye. The imaging setup generates a high number of spectral bands within seconds and allows non-invasive characterization of spectral characteristics with relatively high working distance. Despite the comparatively uniform coloration, spectral reflectivity between 700 and 1100 nm differed markedly among the species. In contrast to H. arborea, L. caerulea and A. callidryas showed reflection in this range. For all three species, reflectivity above 1100 nm is primarily defined by water absorption. Furthermore, the high resolution allowed examining even small structures such as fingers and toes, which in A. callidryas showed an increased reflectivity in the near infrared part of the spectrum. Hyperspectral imaging was found to be a very useful alternative technique combining the spectral resolution of spectrometric measurements with a higher spatial resolution. In addition, we used Digital Infrared/Red-Edge Photography as new simple method to roughly determine the near infrared reflectivity of frog specimens in field, where hyperspectral imaging is typically difficult.
Laryngeal closure impedes non-invasive ventilation at birth
Crawshaw, Jessica R; Kitchen, Marcus J; Binder-Heschl, Corinna; Thio, Marta; Wallace, Megan J; Kerr, Lauren T; Roehr, Charles C; Lee, Katie L; Buckley, Genevieve A; Davis, Peter G; Flemmer, Andreas; te Pas, Arjan B; Hooper, Stuart B
2018-01-01
Background Non-invasive ventilation is sometimes unable to provide the respiratory needs of very premature infants in the delivery room. While airway obstruction is thought to be the main problem, the site of obstruction is unknown. We investigated whether closure of the larynx and epiglottis is a major site of airway obstruction. Methods We used phase contrast X-ray imaging to visualise laryngeal function in spontaneously breathing premature rabbits immediately after birth and at approximately 1 hour after birth. Non-invasive respiratory support was applied via a facemask and images were analysed to determine the percentage of the time the glottis and the epiglottis were open. Hypothesis Immediately after birth, the larynx is predominantly closed, only opening briefly during a breath, making non-invasive intermittent positive pressure ventilation (iPPV) ineffective, whereas after lung aeration, the larynx is predominantly open allowing non-invasive iPPV to ventilate the lung. Results The larynx and epiglottis were predominantly closed (open 25.5%±1.1% and 17.1%±1.6% of the time, respectively) in pups with unaerated lungs and unstable breathing patterns immediately after birth. In contrast, the larynx and the epiglottis were mostly open (90.5%±1.9% and 72.3%±2.3% of the time, respectively) in pups with aerated lungs and stable breathing patterns irrespective of time after birth. Conclusion Laryngeal closure impedes non-invasive iPPV at birth and may reduce the effectiveness of non-invasive respiratory support in premature infants immediately after birth. PMID:29054974
Gaziano, Thomas A; Abrahams-Gessel, Shafika; Denman, Catalina A; Montano, Carlos Mendoza; Khanam, Masuma; Puoane, Thandi; Levitt, Naomi S
2015-09-01
Cardiovascular disease contributes substantially to the non-communicable disease (NCD) burden in low-income and middle-income countries, which also often have substantial health personnel shortages. In this observational study we investigated whether community health workers could do community-based screenings to predict cardiovascular disease risk as effectively as could physicians or nurses, with a simple, non-invasive risk prediction indicator in low-income and middle-income countries. This observation study was done in Bangladesh, Guatemala, Mexico, and South Africa. Each site recruited at least ten to 15 community health workers based on usual site-specific norms for required levels of education and language competency. Community health workers had to reside in the community where the screenings were done and had to be fluent in that community's predominant language. These workers were trained to calculate an absolute cardiovascular disease risk score with a previously validated simple, non-invasive screening indicator. Community health workers who successfully finished the training screened community residents aged 35-74 years without a previous diagnosis of hypertension, diabetes, or heart disease. Health professionals independently generated a second risk score with the same instrument and the two sets of scores were compared for agreement. The primary endpoint of this study was the level of direct agreement between risk scores assigned by the community health workers and the health professionals. Of 68 community health worker trainees recruited between June 4, 2012, and Feb 8, 2013, 42 were deemed qualified to do fieldwork (15 in Bangladesh, eight in Guatemala, nine in Mexico, and ten in South Africa). Across all sites, 4383 community members were approached for participation and 4049 completed screening. The mean level of agreement between the two sets of risk scores was 96·8% (weighted κ=0·948, 95% CI 0·936-0·961) and community health workers showed that 263 (6%) of 4049 people had a 5-year cardiovascular disease risk of greater than 20%. Health workers without formal professional training can be adequately trained to effectively screen for, and identify, people at high risk of cardiovascular disease. Using community health workers for this screening would free up trained health professionals in low-resource settings to do tasks that need high levels of formal, professional training. Copyright © 2015 Gaziano et al. Open Access article published under the terms of CC BY-NC-ND 4.0. Published by Elsevier Ltd.. All rights reserved.
Method and apparatus for non-invasive evaluation of diaphragmatic function
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Wait, Juliette L. (Inventor); Nahormek, Patricia A. (Inventor); Cantrell, John H. (Inventor); Hanna-Hawver, Pamela D. (Inventor)
1995-01-01
A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.
Method and apparatus for non-invasive evaluation of diaphragmatic function
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Wait, Juliette L. (Inventor); Nahormek, Patricia A. (Inventor); Cantrell, John H. (Inventor); Hanna-Hawver, Pamela D. (Inventor)
1994-01-01
A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.
Collaborative research in cardiovascular dynamics and bone elasticity
NASA Technical Reports Server (NTRS)
1974-01-01
A collaborative research program covering a variety of topics of biomechanics and biomedical engineering within the fields of cardiovascular dynamics, respiration, bone elasticity and vestibular physiology is described. The goals of the research were to promote: (1) a better understanding of the mechanical behavior of the circulatory system and its control mechanisms; (2) development of noninvasive methods of measuring the changes in the mechanical properties of blood vessels and other cardiovascular parameters in man; (3) application of these noninvasive methods to examine in man the physiological effects of environmental changes, including earth-simulated gravitational changes; and (4) development of in-flight methods for studying the events which lead to post-flight postural hypotension.
NASA Astrophysics Data System (ADS)
Salvemini, Filomena; Grazzi, Francesco; Kardjilov, Nikolay; Wieder, Frank; Manke, Ingo; Edge, David; Williams, Alan; Zoppi, Marco
2017-05-01
Non-invasive experimental methods play an important role in the field of cultural heritage. Benefiting from the technical progress in recent years, neutron imaging has been demonstrated to complement effectively studies based on surface analysis, allowing for a non-invasive characterization of the whole three-dimensional volume. This study focuses on a kris and a kanjar, two weapons from ancient Asia, to show the potential of the combined use of X-ray and neutron imaging techniques for the characterisation of the manufacturing methods and the authentication of objects of cultural and historical interest.
Processing-optimised imaging of analog geological models by electrical capacitance tomography
NASA Astrophysics Data System (ADS)
Ortiz Alemán, C.; Espíndola-Carmona, A.; Hernández-Gómez, J. J.; Orozco Del Castillo, MG
2017-06-01
In this work, the electrical capacitance tomography (ECT) technique is applied in monitoring internal deformation of geological analog models, which are used to study structural deformation mechanisms, in particular for simulating migration and emplacement of allochtonous salt bodies. A rectangular ECT sensor was used for internal visualization of analog geologic deformation. The monitoring of analog models consists in the reconstruction of permittivity images from the capacitance measurements obtained by introducing the model inside the ECT sensor. A simulated annealing (SA) algorithm is used as a reconstruction method, and is optimized by taking full advantage of some special features in a linearized version of this inverse approach. As a second part of this work our SA image reconstruction algorithm is applied to synthetic models, where its performance is evaluated in comparison to other commonly used algorithms such as linear back-projection and iterative Landweber methods. Finally, the SA method is applied to visualise two simple geological analog models. Encouraging results were obtained in terms of the quality of the reconstructed images, as interfaces corresponding to main geological units in the analog model were clearly distinguishable in them. We found reliable results quite useful for real time non-invasive monitoring of internal deformation of analog geological models.
Lei, Rong; Jiang, Hongshan; Hu, Fan; Yan, Jin; Zhu, Shuifang
2017-02-01
Leaf chlorosis induced by plant virus infection has a short fluorescence lifetime, which reflects damaged photosynthetic complexes and degraded chloroplasts. Plant viruses often induce chlorosis and necrosis, which are intimately related to photosynthetic functions. Chlorophyll fluorescence lifetime measurement is a valuable noninvasive tool for analyzing photosynthetic processes and is a sensitive indicator of the environment surrounding the fluorescent molecules. In this study, our central goal was to explore the effect of viral infection on photosynthesis by employing chlorophyll fluorescence lifetime imaging (FLIM), steady-state fluorescence, non-photochemical quenching (NPQ), transmission electron microscopy (TEM), and pigment analysis. The data indicated that the chlorophyll fluorescence lifetime of chlorotic leaves was significantly shorter than that of healthy control leaves, and the fitted short lifetime component of chlorophyll fluorescence of chlorotic leaves was dominant. This dominant short lifetime component may result from damage to the structure of thylakoid, which was confirmed by TEM. The NPQ value of chlorotic leaves was slightly higher than that of healthy green leaves, which can be explained by increased neoxanthin, lutein and violaxanthin content relative to chlorophyll a. The difference in NPQ is slight, but FLIM can provide simple and direct characterization of PSII structure and photosynthetic function. Therefore, this technique shows great potential as a simple and rapid method for studying mechanisms of plant virus infection.
Shimizu, Miyuki; Kinoshita, Kensuke; Maeno, Takami; Kobayashi, Hiroyuki; Maeno, Tetsuhiro
2017-11-01
Dehydration in older patients has long been considered a significant health problem because it implies increased morbidity and mortality. However, dehydration is detected by a combination of physical signs and blood tests. For older people dwelling at home and in nursing homes, a simple and non-invasive method for detecting dehydration by caregivers is needed. The total body resistance is measured using bioelectrical impedance analysis and is known as an indicator of dehydration. There are no data from older Japanese patients on this issue. We performed this study to examine the relationship between dehydration and total body resistance in Japan. We performed blood tests and measured bioelectrical impedance in older outpatients aged ≥ 65 years from the Internal Medicine Department at Mito Kyodo General Hospital. Patients were classified as dehydrated and non-dehydrated using the dehydration index with a blood urea nitrogen/creatinine ratio > 20, and the mean total body resistance was compared between the two groups. Eighty-one patients were recruited in the study. In the dehydrated group, the mean total body resistance was 439 Ω at 50 kHz, which was significantly higher than that in the non-dehydrated group (408 Ω, P = 0.038). The total body resistance measurements can be used for simple assessment of dehydration among older Japanese patients.
Kero, Tanja; Lindsjö, Lars; Sörensen, Jens; Lubberink, Mark
2016-08-01
(11)C-PIB PET is a promising non-invasive diagnostic tool for cardiac amyloidosis. Semiautomatic analysis of PET data is now available but it is not known how accurate these methods are for amyloid imaging. The aim of this study was to evaluate the feasibility of one semiautomatic software tool for analysis and visualization of (11)C-PIB left ventricular retention index (RI) in cardiac amyloidosis. Patients with systemic amyloidosis and cardiac involvement (n = 10) and healthy controls (n = 5) were investigated with dynamic (11)C-PIB PET. Two observers analyzed the PET studies with semiautomatic software to calculate the left ventricular RI of (11)C-PIB and to create parametric images. The mean RI at 15-25 min from the semiautomatic analysis was compared with RI based on manual analysis and showed comparable values (0.056 vs 0.054 min(-1) for amyloidosis patients and 0.024 vs 0.025 min(-1) in healthy controls; P = .78) and the correlation was excellent (r = 0.98). Inter-reader reproducibility also was excellent (intraclass correlation coefficient, ICC > 0.98). Parametric polarmaps and histograms made visual separation of amyloidosis patients and healthy controls fast and simple. Accurate semiautomatic analysis of cardiac (11)C-PIB RI in amyloidosis patients is feasible. Parametric polarmaps and histograms make visual interpretation fast and simple.
Özdemir, Merve Erkınay; Telatar, Ziya; Eroğul, Osman; Tunca, Yusuf
2018-05-01
Dysmorphic syndromes have different facial malformations. These malformations are significant to an early diagnosis of dysmorphic syndromes and contain distinctive information for face recognition. In this study we define the certain features of each syndrome by considering facial malformations and classify Fragile X, Hurler, Prader Willi, Down, Wolf Hirschhorn syndromes and healthy groups automatically. The reference points are marked on the face images and ratios between the points' distances are taken into consideration as features. We suggest a neural network based hierarchical decision tree structure in order to classify the syndrome types. We also implement k-nearest neighbor (k-NN) and artificial neural network (ANN) classifiers to compare classification accuracy with our hierarchical decision tree. The classification accuracy is 50, 73 and 86.7% with k-NN, ANN and hierarchical decision tree methods, respectively. Then, the same images are shown to a clinical expert who achieve a recognition rate of 46.7%. We develop an efficient system to recognize different syndrome types automatically in a simple, non-invasive imaging data, which is independent from the patient's age, sex and race at high accuracy. The promising results indicate that our method can be used for pre-diagnosis of the dysmorphic syndromes by clinical experts.
NASA Astrophysics Data System (ADS)
Lademann, J.; Richter, H.; Astner, S.; Patzelt, A.; Knorr, F.; Sterry, W.; Antoniou, Ch
2008-04-01
Normal skin barrier function is an essential aspect of skin homeostasis and regeneration. Dynamic inflammatory, proliferative and neoplastic skin processes such as wound healing, psoriasis and contact dermatitis are associated with a significant disruption of the skin barrier. In recent years, there has been increasing interest in evaluating cosmetic and pharmacologic products for their ability to restore these protective properties. The gold standard for characterization of barrier function has been the measurement of the transepidermal water loss, however the disadvantage of this method is its interference with several endogenous and exogenous factors such as hydration, perspiration and topically applied substances. This study was aimed to test the clinical applicability of a fluorescence confocal laser scanning microscope (LSM) for a systematic morphologic analysis of the structure, integrity and thickness of the stratum corneum in 10 otherwise healthy volunteers. The influence of skin treatment with commercial moisturizing cream on skin barrier function was evaluated in serial non-invasive examinations. Our findings showed that in vivo LSM may represent a simple and efficient method for the characterization of skin barrier properties, such as the thickness and hydration of the stratum corneum.
Medical radar considerations for detecting and monitoring Crohn's disease
NASA Astrophysics Data System (ADS)
Smith, Sonny; Narayanan, Ram M.; Messaris, Evangelos
2014-05-01
Crohn's disease is a condition that causes inflammation and associated complications along any section of the digestive tract. Over the years, numerous radiological and endoscopic methods as well as the use of ultrasound have been developed to examine and diagnose inflammatory bowel disorders such as Crohn's disease. While such techniques have much merit, an alternative medical solution that is safe, non-invasive, and inexpensive is proposed in this paper. Reflections from electromagnetic signals transmitted by an ultra-wide band (UWB) radar allow for not only range (or extent) information but also spectral analysis of a given target of interest. Moreover, the radar cross-section (RCS) of an object measures how detectable the electromagnetic return energy of such an object is to the radar. In the preliminary phase of research, we investigate how disparities in the dielectric properties of diseased versus non-diseased portions of the intestines can aid in the detection of Crohn's disease. RCS analysis from finite-difference time-domain (FDTD) method simulations using a simple 3D model of the intestines are presented. The ultimate goal of our research is to design a UWB radar system using a suitable waveform to detect and monitor Crohn's disease.
Age estimation using exfoliative cytology and radiovisiography: A comparative study
Nallamala, Shilpa; Guttikonda, Venkateswara Rao; Manchikatla, Praveen Kumar; Taneeru, Sravya
2017-01-01
Introduction: Age estimation is one of the essential factors in establishing the identity of an individual. Among various methods, exfoliative cytology (EC) is a unique, noninvasive technique, involving simple, and pain-free collection of intact cells from the oral cavity for microscopic examination. Objective: The study was undertaken with an aim to estimate the age of an individual from the average cell size of their buccal smears calculated using image analysis morphometric software and the pulp–tooth area ratio in mandibular canine of the same individual using radiovisiography (RVG). Materials and Methods: Buccal smears were collected from 100 apparently healthy individuals. After fixation in 95% alcohol, the smears were stained using Papanicolaou stain. The average cell size was measured using image analysis software (Image-Pro Insight 8.0). The RVG images of mandibular canines were obtained, pulp and tooth areas were traced using AutoCAD 2010 software, and area ratio was calculated. The estimated age was then calculated using regression analysis. Results: The paired t-test between chronological age and estimated age by cell size and pulp–tooth area ratio was statistically nonsignificant (P > 0.05). Conclusion: In the present study, age estimated by pulp–tooth area ratio and EC yielded good results. PMID:29657491
Bhattacharya, Tinish; Gupta, Ankesh; Singh, Salam ThoiThoi; Roy, Sitikantha; Prasad, Anamika
2017-07-01
Cuff-less and non-invasive methods of Blood Pressure (BP) monitoring have faced a lot of challenges like stability, noise, motion artefact and requirement for calibration. These factors are the major reasons why such devices do not get approval from the medical community easily. One such method is calculating Blood Pressure indirectly from pulse transit time (PTT) obtained from electrocardiogram (ECG) and Photoplethysmogram (PPG). In this paper we have proposed two novel analog signal conditioning circuits for ECG and PPG that increase stability, remove motion artefacts, remove the sinusoidal wavering of the ECG baseline due to respiration and provide consistent digital pulses corresponding to blood pulses/heart-beat. We have combined these two systems to obtain the PTT and then correlated it with the Mean Arterial Pressure (MAP). The aim was to perform major part of the processing in analog domain to decrease processing load over microcontroller so as to reduce cost and make it simple and robust. We have found from our experiments that the proposed circuits can calculate the Heart Rate (HR) with a maximum error of ~3.0% and MAP with a maximum error of ~2.4% at rest and ~4.6% in motion.
Auray-Blais, Christiane; Lavoie, Pamela; Boutin, Michel; Abaoui, Mona
2017-04-06
Fabry disease is a complex, panethnic lysosomal storage disorder. It is characterized by the accumulation of glycosphingolipids in tissues, organs, the vascular endothelium, and biological fluids. The reported incidence in different populations is quite variable, ranging from 1:1400 to 1:117,000. Its complexity lies in the marked genotypic and phenotypic heterogeneity. Despite the fact that it is an X-linked disease, more than 600 mutations affect both males and females. In fact, some females may be affected as severely as males. The purpose of this protocol is to focus on the high-risk screening of patients who might have Fabry disease using a simple, rapid, non-invasive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for urinary globotriaosylceramide (Gb 3 ) analysis. Urine filter paper samples are easily collected at home by patients and sent by regular mail. This method has been successfully used for high-risk screening of patients with ophthalmologic manifestations and in an on-going study for high-risk screening of Fabry disease in patients with chronic kidney diseases. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.
Statistics of Optical Coherence Tomography Data From Human Retina
de Juan, Joaquín; Ferrone, Claudia; Giannini, Daniela; Huang, David; Koch, Giorgio; Russo, Valentina; Tan, Ou; Bruni, Carlo
2010-01-01
Optical coherence tomography (OCT) has recently become one of the primary methods for noninvasive probing of the human retina. The pseudoimage formed by OCT (the so-called B-scan) varies probabilistically across pixels due to complexities in the measurement technique. Hence, sensitive automatic procedures of diagnosis using OCT may exploit statistical analysis of the spatial distribution of reflectance. In this paper, we perform a statistical study of retinal OCT data. We find that the stretched exponential probability density function can model well the distribution of intensities in OCT pseudoimages. Moreover, we show a small, but significant correlation between neighbor pixels when measuring OCT intensities with pixels of about 5 µm. We then develop a simple joint probability model for the OCT data consistent with known retinal features. This model fits well the stretched exponential distribution of intensities and their spatial correlation. In normal retinas, fit parameters of this model are relatively constant along retinal layers, but varies across layers. However, in retinas with diabetic retinopathy, large spikes of parameter modulation interrupt the constancy within layers, exactly where pathologies are visible. We argue that these results give hope for improvement in statistical pathology-detection methods even when the disease is in its early stages. PMID:20304733
Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C
2018-06-01
An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as studies evaluating alternatives to the finger for capturing the raw signals for hemodynamic assessment, and, finally, studies evaluating technologies based on a flow time measurement are current topics of clinical research.
A potential non-invasive approach to evaluating blastocyst quality using biodynamic imaging
NASA Astrophysics Data System (ADS)
Li, Zhe; Ehmke, Natalie; Machaty, Zoltan; Nolte, David
2018-02-01
Biodynamic imaging (BDI) is capable of capturing the intracellular dynamics of blastocysts within a relatively short time. Spectroscopic signatures of embryos in the 0.01 Hz - 1 Hz range display responses to external factors before morphology changes take place. Viability evaluation is consistent with results from other non-invasive methods. Biodynamic imaging is a potential tool for selecting high quality embryos in clinical IVF practices.
Fetal sex determination in twin pregnancies using cell free fetal DNA analysis.
Milan, Miguel; Mateu, Emilia; Blesa, David; Clemente-Ciscar, Monica; Simon, Carlos
2018-04-23
We sought to develop an accurate sex classification method in twin pregnancies using data obtained from a standard commercial non-invasive prenatal test. A total of 706 twin pregnancies were included in this retrospective analytical data study. Normalized chromosome values for chromosomes X and Y were used and adapted into a sex-score to predict fetal sex in each fetus, and results were compared with the clinical outcome at birth. Outcome information at birth for sex chromosomes was available for 232 twin pregnancies. From these, a total of 173 twin pregnancies with a Y chromosome identified in non-invasive pregnancy testing were used for the development of a predictive model. Global accuracy for sex classification in the testing set with 51 samples was 0.98 (95% confidence interval [0.90,0.99]), with a specificity and sensitivity of 1 (95% confidence interval [0.82,1.00]) and 0.97 (95% confidence interval [0.84,0.99]), respectively. While non-invasive prenatal testing is a screening method and confirmatory results must be obtained by ultrasound or genetic diagnosis, the sex-score determination presented herein offers an accurate and useful approach to characterizing fetus sex in twin pregnancies in a non-invasive manner early on in pregnancy. © 2018 John Wiley & Sons, Ltd.
Non-invasive peripheral nerve stimulation via focused ultrasound in vivo
NASA Astrophysics Data System (ADS)
Downs, Matthew E.; Lee, Stephen A.; Yang, Georgiana; Kim, Seaok; Wang, Qi; Konofagou, Elisa E.
2018-02-01
Focused ultrasound (FUS) has been employed on a wide range of clinical applications to safely and non-invasively achieve desired effects that have previously required invasive and lengthy procedures with conventional methods. Conventional electrical neuromodulation therapies that are applied to the peripheral nervous system (PNS) are invasive and/or non-specific. Recently, focused ultrasound has demonstrated the ability to modulate the central nervous system and ex vivo peripheral neurons. Here, for the first time, noninvasive stimulation of the sciatic nerve eliciting a physiological response in vivo is demonstrated with FUS. FUS was applied on the sciatic nerve in mice with simultaneous electromyography (EMG) on the tibialis anterior muscle. EMG signals were detected during or directly after ultrasound stimulation along with observable muscle contraction of the hind limb. Transecting the sciatic nerve downstream of FUS stimulation eliminated EMG activity during FUS stimulation. Peak-to-peak EMG response amplitudes and latency were found to be comparable to conventional electrical stimulation methods. Histology along with behavioral and thermal testing did not indicate damage to the nerve or surrounding regions. The findings presented herein demonstrate that FUS can serve as a targeted, safe and non-invasive alternative to conventional peripheral nervous system stimulation to treat peripheral neuropathic diseases in the clinic.
Griffiths, C. J.; Pickard, R. S.
2009-01-01
Objective: This article defines the need for objective measurements to help diagnose the cause of lower urinary tract symptoms (LUTS). It describes the conventional techniques available, mainly invasive, and then summarizes the emerging range of non-invasive measurement techniques. Methods: This is a narrative review derived form the clinical and scientific knowledge of the authors together with consideration of selected literature. Results: Consideration of measured bladder pressure urinary flow rate during voiding in an invasive pressure flow study is considered the gold standard for categorization of bladder outlet obstruction (BOO). The diagnosis is currently made by plotting the detrusor pressure at maximum flow (pdetQmax) and maximum flow rate (Qmax) on the nomogram approved by the International Continence Society. This plot will categorize the void as obstructed, equivocal or unobstructed. The invasive and relatively complex nature of this investigation has led to a number of inventive techniques to categorize BOO either by measuring bladder pressure non-invasively or by providing a proxy measure such as bladder weight. Conclusion: Non-invasive methods of diagnosing BOO show great promise and a few have reached the stage of being commercially available. Further studies are however needed to validate the measurement technique and assess their worth in the assessment of men with LUTS. PMID:19468436
Non-invasive diagnosis of liver fibrosis in chronic hepatitis C
Schiavon, Leonardo de Lucca; Narciso-Schiavon, Janaína Luz; de Carvalho-Filho, Roberto José
2014-01-01
Assessment of liver fibrosis in chronic hepatitis C virus (HCV) infection is considered a relevant part of patient care and key for decision making. Although liver biopsy has been considered the gold standard for staging liver fibrosis, it is an invasive technique and subject to sampling errors and significant intra- and inter-observer variability. Over the last decade, several noninvasive markers were proposed for liver fibrosis diagnosis in chronic HCV infection, with variable performance. Besides the clear advantage of being noninvasive, a more objective interpretation of test results may overcome the mentioned intra- and inter-observer variability of liver biopsy. In addition, these tests can theoretically offer a more accurate view of fibrogenic events occurring in the entire liver with the advantage of providing frequent fibrosis evaluation without additional risk. However, in general, these tests show low accuracy in discriminating between intermediate stages of fibrosis and may be influenced by several hepatic and extra-hepatic conditions. These methods are either serum markers (usually combined in a mathematical model) or imaging modalities that can be used separately or combined in algorithms to improve accuracy. In this review we will discuss the different noninvasive methods that are currently available for the evaluation of liver fibrosis in chronic hepatitis C, their advantages, limitations and application in clinical practice. PMID:24659877
Non-invasive detection of language-related prefrontal high gamma band activity with beamforming MEG.
Hashimoto, Hiroaki; Hasegawa, Yuka; Araki, Toshihiko; Sugata, Hisato; Yanagisawa, Takufumi; Yorifuji, Shiro; Hirata, Masayuki
2017-10-27
High gamma band (>50 Hz) activity is a key oscillatory phenomenon of brain activation. However, there has not been a non-invasive method established to detect language-related high gamma band activity. We used a 160-channel whole-head magnetoencephalography (MEG) system equipped with superconducting quantum interference device (SQUID) gradiometers to non-invasively investigate neuromagnetic activities during silent reading and verb generation tasks in 15 healthy participants. Individual data were divided into alpha (8-13 Hz), beta (13-25 Hz), low gamma (25-50 Hz), and high gamma (50-100 Hz) bands and analysed with the beamformer method. The time window was consecutively moved. Group analysis was performed to delineate common areas of brain activation. In the verb generation task, transient power increases in the high gamma band appeared in the left middle frontal gyrus (MFG) at the 550-750 ms post-stimulus window. We set a virtual sensor on the left MFG for time-frequency analysis, and high gamma event-related synchronization (ERS) induced by a verb generation task was demonstrated at 650 ms. In contrast, ERS in the high gamma band was not detected in the silent reading task. Thus, our study successfully non-invasively measured language-related prefrontal high gamma band activity.
Magnetically engineered smart thin films: toward lab-on-chip ultra-sensitive molecular imaging.
Hassan, Muhammad A; Saqib, Mudassara; Shaikh, Haseeb; Ahmad, Nasir M; Elaissari, Abdelhamid
2013-03-01
Magnetically responsive engineered smart thin films of nanoferrites as contrast agent are employed to develop surface based magnetic resonance imaging to acquire simple yet fast molecular imaging. The work presented here can be of significant potential for future lab-on-chip point-of-care diagnostics from the whole blood pool on almost any substrates to reduce or even prevent clinical studies involve a living organism to enhance the non-invasive imaging to advance the '3Rs' of work in animals-replacement, refinement and reduction.
Hierarchical nanostructured WO3-SnO2 for selective sensing of volatile organic compounds
NASA Astrophysics Data System (ADS)
Nayak, Arpan Kumar; Ghosh, Ruma; Santra, Sumita; Guha, Prasanta Kumar; Pradhan, Debabrata
2015-07-01
It remains a challenge to find a suitable gas sensing material that shows a high response and shows selectivity towards various gases simultaneously. Here, we report a mixed metal oxide WO3-SnO2 nanostructured material synthesized in situ by a simple, single-step, one-pot hydrothermal method at 200 °C in 12 h, and demonstrate its superior sensing behavior towards volatile organic compounds (VOCs) such as ammonia, ethanol and acetone. SnO2 nanoparticles with controlled size and density were uniformly grown on WO3 nanoplates by varying the tin precursor. The density of the SnO2 nanoparticles on the WO3 nanoplates plays a crucial role in the VOC selectivity. The responses of the present mixed metal oxides are found to be much higher than the previously reported results based on single/mixed oxides and noble metal-doped oxides. In addition, the VOC selectivity is found to be highly temperature-dependent, with optimum performance obtained at 200 °C, 300 °C and 350 °C for ammonia, ethanol and acetone, respectively. The present results on the cost-effective noble metal-free WO3-SnO2 sensor could find potential application in human breath analysis by non-invasive detection.It remains a challenge to find a suitable gas sensing material that shows a high response and shows selectivity towards various gases simultaneously. Here, we report a mixed metal oxide WO3-SnO2 nanostructured material synthesized in situ by a simple, single-step, one-pot hydrothermal method at 200 °C in 12 h, and demonstrate its superior sensing behavior towards volatile organic compounds (VOCs) such as ammonia, ethanol and acetone. SnO2 nanoparticles with controlled size and density were uniformly grown on WO3 nanoplates by varying the tin precursor. The density of the SnO2 nanoparticles on the WO3 nanoplates plays a crucial role in the VOC selectivity. The responses of the present mixed metal oxides are found to be much higher than the previously reported results based on single/mixed oxides and noble metal-doped oxides. In addition, the VOC selectivity is found to be highly temperature-dependent, with optimum performance obtained at 200 °C, 300 °C and 350 °C for ammonia, ethanol and acetone, respectively. The present results on the cost-effective noble metal-free WO3-SnO2 sensor could find potential application in human breath analysis by non-invasive detection. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr02571k
Maggi, Roberto; Viscardi, Valentina; Furukawa, Toshiyuki; Brignole, Michele
2010-01-01
Aims We thought to evaluate feasibility of continuous non-invasive blood pressure monitoring during procedures of interventional electrophysiology. Methods and results We evaluated continuous non-invasive finger blood pressure (BP) monitoring by means of the Nexfin device in 22 patients (mean age 70 ± 24 years), undergoing procedures of interventional electrophysiology, in critical situations of hypotension caused by tachyarrhythmias or by intermittent incremental ventricular temporary pacing till to the maximum tolerated systolic BP fall (mean 61 ± 14 mmHg per patient at a rate of 195 ± 37 bpm). In all patients, Nexfin was able to detect immediately, at the onset of tachyarrythmia, the changes in BP and recorded reliable waveforms. The quality of the signal was arbitrarily classified as excellent in 11 cases, good in 10 cases, and sufficient in 1 case. In basal conditions, calibrations of the signal occurred every 49.2 ± 24.3 s and accounted for 4% of total monitoring time; during tachyarrhythmias their frequency increased to one every 12.7 s and accounted for 19% of total recording duration. A linear correlation for a range of BP values from 41 to 190 mmHg was found between non-invasive and intra-arterial BP among a total of 1055 beats from three patients who underwent simultaneous recordings with both methods (coefficient of correlation of 0.81, P < 0.0001). Conclusion In conclusion, continuous non-invasive BP monitoring is feasible in the clinical practise of an interventional electrophysiology laboratory without the need of utilization of an intra-arterial BP line. PMID:20837572
Development and validation of a MRgHIFU non-invasive tissue acoustic property estimation technique.
Johnson, Sara L; Dillon, Christopher; Odéen, Henrik; Parker, Dennis; Christensen, Douglas; Payne, Allison
2016-11-01
MR-guided high-intensity focussed ultrasound (MRgHIFU) non-invasive ablative surgeries have advanced into clinical trials for treating many pathologies and cancers. A remaining challenge of these surgeries is accurately planning and monitoring tissue heating in the face of patient-specific and dynamic acoustic properties of tissues. Currently, non-invasive measurements of acoustic properties have not been implemented in MRgHIFU treatment planning and monitoring procedures. This methods-driven study presents a technique using MR temperature imaging (MRTI) during low-temperature HIFU sonications to non-invasively estimate sample-specific acoustic absorption and speed of sound values in tissue-mimicking phantoms. Using measured thermal properties, specific absorption rate (SAR) patterns are calculated from the MRTI data and compared to simulated SAR patterns iteratively generated via the Hybrid Angular Spectrum (HAS) method. Once the error between the simulated and measured patterns is minimised, the estimated acoustic property values are compared to the true phantom values obtained via an independent technique. The estimated values are then used to simulate temperature profiles in the phantoms, and compared to experimental temperature profiles. This study demonstrates that trends in acoustic absorption and speed of sound can be non-invasively estimated with average errors of 21% and 1%, respectively. Additionally, temperature predictions using the estimated properties on average match within 1.2 °C of the experimental peak temperature rises in the phantoms. The positive results achieved in tissue-mimicking phantoms presented in this study indicate that this technique may be extended to in vivo applications, improving HIFU sonication temperature rise predictions and treatment assessment.
Obeid, Hasan; Khettab, Hakim; Marais, Louise; Hallab, Magid; Laurent, Stéphane; Boutouyrie, Pierre
2017-08-01
Carotid-femoral pulse wave velocity (PWV) (cf-PWV) is the gold standard for measuring aortic stiffness. Finger-toe PWV (ft-PWV) is a simpler noninvasive method for measuring arterial stiffness. Although the validity of the method has been previously assessed, its accuracy can be improved. ft-PWV is determined on the basis of a patented height chart for the distance and the pulse transit time (PTT) between the finger and the toe pulpar arteries signals (ft-PTT). The objective of the first study, performed in 66 patients, was to compare different algorithms (intersecting tangents, maximum of the second derivative, 10% threshold and cross-correlation) for determining the foot of the arterial pulse wave, thus the ft-PTT. The objective of the second study, performed in 101 patients, was to investigate different signal processing chains to improve the concordance of ft-PWV with the gold-standard cf-PWV. Finger-toe PWV (ft-PWV) was calculated using the four algorithms. The best correlations relating ft-PWV and cf-PWV, and relating ft-PTT and carotid-femoral PTT were obtained with the maximum of the second derivative algorithm [PWV: r = 0.56, P < 0.0001, root mean square error (RMSE) = 0.9 m/s; PTT: r = 0.61, P < 0.001, RMSE = 12 ms]. The three other algorithms showed lower correlations. The correlation between ft-PTT and carotid-femoral PTT further improved (r = 0.81, P < 0.0001, RMSE = 5.4 ms) when the maximum of the second derivative algorithm was combined with an optimized signal processing chain. Selecting the maximum of the second derivative algorithm for detecting the foot of the pressure waveform, and combining it with an optimized signal processing chain, improved the accuracy of ft-PWV measurement in the current population sample. Thus, it makes ft-PWV very promising for the simple noninvasive determination of aortic stiffness in clinical practice.
Samal, Ajit Gopal; Behera, Prativa Kumari; Mohanty, Akshay Kumar; Satpathi, Sanghamitra; Kumar, Abhishek; Panda, Rabi Ratna; Minz, Aruna Mukti; Mohanty, Sanjib; Samal, Abhijit; Van Der Pluijm, Rob W
2017-10-01
Rapid and accurate diagnosis is crucial in the treatment of malaria. Rapid Diagnostic Tests (RDTs) using blood have been recommended by the WHO as an acceptable method for the diagnosis of malaria. RDTs provide results quickly, is simple to use and easy to interpret. However, its use requires collection of blood by skin puncture. Hence the aim of the pilot study is to explore the sensitivity and specificity of RDTs using urine (collected non-invasively) for diagnosis of Plasmodium falciparum malaria and to assess the relation between parasite density in blood with HRP-2 Ag detection in urine. All fever cases admitted to Ispat General Hospital (IGH) Rourkela, India, during June 2012-March 2013 with a clinical diagnosis of malaria were examined for the presence of asexual forms of P. falciparum in peripheral blood smears. All smear positive febrile patients who met the eligibility criteria were enrolled. Smear negative fever cases were enrolled as control cases. RDTs were performed using both urine and blood samples by using commercially available blood specific kits. Sixty blood smear positive cases and 51 febrile blood smear negative cases were enrolled. Sensitivity and specificity of RDT urine were 86.67% (95%CI:75.83-93.09) and 94.12% (95%CI:84.08-97.98) respectively whereas those of RDT blood were 91.67% (95% CI: 81.93-96.39) and 98.04% (95% CI 89.7-99.65). The sensitivity of both RDT urine as well as RDT blood were found to be dependent on the level of parasitemia. Results of this study are promising. Larger studies are needed to assess whether RDTs using urine could serve as a practical, reliable method for the detection of P. falciparum in a non-invasive manner where invasive blood taking is less feasible.
Fidalgo, L E; López-Beceiro, A M; Vila-Pastor, M; Martínez-Carrasco, C; Barreiro-Vázquez, J D; Pérez, J M
2015-03-01
This study was conducted to assess the reliability of computed tomography (CT) for diagnosing bot fly infestations by Cephenemyia stimulator (Clark) (Diptera: Oestridae) in roe deer (Capreolus capreolus L.) (Artiodactyla: Cervidae). For this purpose, the heads of 30 animals were analysed, firstly by CT and then by necropsy, which was used as the reference standard method. The prevalence values obtained by both methods were identical; the prevalence of infestation was 40.0% overall, and was higher in males (45.5%) than in females (25.0%). These results highlight the usefulness of CT as an alternative or non-invasive method for diagnosing cephenemyiosis in live-captured roe deer and in hunting trophies or museum collections that cannot be destroyed or damaged. © 2014 The Royal Entomological Society.
Seino, Yoshihiko; Momomura, Shin-Ichi; Kihara, Yasuki; Adachi, Hitoshi; Yasumura, Yoshio; Yokoyama, Hiroyuki
2015-01-16
Adaptive servo-ventilation (ASV) therapy, which is a form of noninvasive positive pressure ventilation therapy and uses an innovative ventilator that has simple operability and provides good patient adherence, potentially has therapeutic benefits-suppression of the deterioration and progression of chronic heart failure (CHF) and a reduction in the number of repeated hospitalizations. Therefore, ASV therapy draws attention as a novel, noninvasive nonpharmacotherapy for patients with CHF owing to its hemodynamics-improving effect, and it is currently being accepted in real-world clinical settings in Japan. However, clinical evidence sufficient for treatment recommendation is lacking because a multicenter, randomized, controlled study of ASV therapy has never been conducted. The present study is a confirmatory, prospective, multicenter, collaborative, open-label, blinded-endpoint, parallel-group, randomized, controlled study. At 40 medical institutions in Japan, 200 Japanese outpatients with mild to severe CHF (age: ≥ 20 years; New York Heart Association classification: greater than or equal to class II) will be randomly assigned to either of the following two study groups: the ASV group, in which 100 outpatients undergo guideline-directed medical therapy and ASV therapy for 24 weeks; and the control group, in which 100 outpatients undergo only guideline-directed medical therapy for 24 weeks. The objective of the present study is to confirm whether the ASV group is superior to the control group concerning the improvement of left ventricular contractility and remodeling, both assessed by two-dimensional echocardiography. Furthermore, the present study will also secondarily examine the effects of ASV therapy on the prognosis and quality of life of patients with CHF. ASV therapy using the device has the potential to provide therapeutic benefits based on its simple operability and good patient adherence and possesses the potential to improve left ventricular contractility and remodeling. Therefore, the present study is expected to afford more solid scientific evidence regarding ASV therapy as a novel, noninvasive, nonpharmacological, in-home, long-term ventilation therapy for patients with mild to severe CHF. UMIN identifier: UMIN000006549 , registered on 17 October, 2011.
Boore, D.M.; Asten, M.W.
2008-01-01
Many groups contributed to a blind interpretation exercise for the determination of shear-wave slowness beneath the Santa Clara Valley. The methods included invasive methods in deep boreholes as well as noninvasive methods using active and passive sources, at six sites within the valley (with most investigations being conducted at a pair of closely spaced sites near the center of the valley). Although significant variability exists between the models, the slownesses from the various methods are similar enough that linear site amplifications estimated in several ways are generally within 20% of one another. The methods were able to derive slownesses that increase systematically with distance from the valley edge, corresponding to a tendency for the sites to be underlain by finer-grained materials away from the valley edge. This variation is in agreement with measurements made in the boreholes at the sites.
A review of MRI evaluation of demyelination in cuprizone murine model
NASA Astrophysics Data System (ADS)
Krutenkova, E.; Pan, E.; Khodanovich, M.
2015-11-01
The cuprizone mouse model of non-autoimmune demyelination reproduces some phenomena of multiple sclerosis and is appropriate for validation and specification of a new method of non-invasive diagnostics. In the review new data which are collected using the new MRI method are compared with one or more conventional MRI tools. Also the paper reviewed the validation of MRI approaches using histological or immunohistochemical methods. Luxol fast blue histological staining and myelin basic protein immunostaining is widespread. To improve the accuracy of non-invasive conventional MRI, multimodal scanning could be applied. The new quantitative MRI method of fast mapping of the macromolecular proton fraction is a reliable biomarker of myelin in the brain and can be used for research of demyelination in animals. To date, a validation of MPF method on the CPZ mouse model of demyelination is not performed, although this method is probably the best way to evaluate demyelination using MRI.
Proof-of-principle rapid noninvasive prenatal diagnosis of autosomal recessive founder mutations
Zeevi, David A.; Altarescu, Gheona; Weinberg-Shukron, Ariella; Zahdeh, Fouad; Dinur, Tama; Chicco, Gaya; Herskovitz, Yair; Renbaum, Paul; Elstein, Deborah; Levy-Lahad, Ephrat; Rolfs, Arndt; Zimran, Ari
2015-01-01
BACKGROUND. Noninvasive prenatal testing can be used to accurately detect chromosomal aneuploidies in circulating fetal DNA; however, the necessity of parental haplotype construction is a primary drawback to noninvasive prenatal diagnosis (NIPD) of monogenic disease. Family-specific haplotype assembly is essential for accurate diagnosis of minuscule amounts of circulating cell-free fetal DNA; however, current haplotyping techniques are too time-consuming and laborious to be carried out within the limited time constraints of prenatal testing, hampering practical application of NIPD in the clinic. Here, we have addressed this pitfall and devised a universal strategy for rapid NIPD of a prevalent mutation in the Ashkenazi Jewish (AJ) population. METHODS. Pregnant AJ couples, carrying mutation(s) in GBA, which encodes acid β-glucosidase, were recruited at the SZMC Gaucher Clinic. Targeted next-generation sequencing of GBA-flanking SNPs was performed on peripheral blood samples from each couple, relevant mutation carrier family members, and unrelated individuals who are homozygotes for an AJ founder mutation. Allele-specific haplotypes were constructed based on linkage, and a consensus Gaucher disease–associated founder mutation–flanking haplotype was fine mapped. Together, these haplotypes were used for NIPD. All test results were validated by conventional prenatal or postnatal diagnostic methods. RESULTS. Ten parental alleles in eight unrelated fetuses were diagnosed successfully based on the noninvasive method developed in this study. The consensus mutation–flanking haplotype aided diagnosis for 6 of 9 founder mutation alleles. CONCLUSIONS. The founder NIPD method developed and described here is rapid, economical, and readily adaptable for prenatal testing of prevalent autosomal recessive disease-causing mutations in an assortment of worldwide populations. FUNDING. SZMC, Protalix Biotherapeutics Inc., and Centogene AG. PMID:26426075
Cardim, Danilo; Robba, C; Bohdanowicz, M; Donnelly, J; Cabella, B; Liu, X; Cabeleira, M; Smielewski, P; Schmidt, B; Czosnyka, M
2016-12-01
Although intracranial pressure (ICP) is essential to guide management of patients suffering from acute brain diseases, this signal is often neglected outside the neurocritical care environment. This is mainly attributed to the intrinsic risks of the available invasive techniques, which have prevented ICP monitoring in many conditions affecting the intracranial homeostasis, from mild traumatic brain injury to liver encephalopathy. In such scenario, methods for non-invasive monitoring of ICP (nICP) could improve clinical management of these conditions. A review of the literature was performed on PUBMED using the search keywords 'Transcranial Doppler non-invasive intracranial pressure.' Transcranial Doppler (TCD) is a technique primarily aimed at assessing the cerebrovascular dynamics through the cerebral blood flow velocity (FV). Its applicability for nICP assessment emerged from observation that some TCD-derived parameters change during increase of ICP, such as the shape of FV pulse waveform or pulsatility index. Methods were grouped as: based on TCD pulsatility index; aimed at non-invasive estimation of cerebral perfusion pressure and model-based methods. Published studies present with different accuracies, with prediction abilities (AUCs) for detection of ICP ≥20 mmHg ranging from 0.62 to 0.92. This discrepancy could result from inconsistent assessment measures and application in different conditions, from traumatic brain injury to hydrocephalus and stroke. Most of the reports stress a potential advantage of TCD as it provides the possibility to monitor changes of ICP in time. Overall accuracy for TCD-based methods ranges around ±12 mmHg, with a great potential of tracing dynamical changes of ICP in time, particularly those of vasogenic nature.
Kang, Yeona; Mozley, P David; Verma, Ajay; Schlyer, David; Henchcliffe, Claire; Gauthier, Susan A; Chiao, Ping C; He, Bin; Nikolopoulou, Anastasia; Logan, Jean; Sullivan, Jenna M; Pryor, Kane O; Hesterman, Jacob; Kothari, Paresh J; Vallabhajosula, Shankar
2018-05-04
Neuroinflammation has been implicated in the pathophysiology of Parkinson's disease (PD), which might be influenced by successful neuroprotective drugs. The uptake of [ 11 C](R)-PK11195 (PK) is often considered to be a proxy for neuroinflammation, and can be quantified using the Logan graphical method with an image-derived blood input function, or the Logan reference tissue model using automated reference region extraction. The purposes of this study were (1) to assess whether these noninvasive image analysis methods can discriminate between patients with PD and healthy volunteers (HVs), and (2) to establish the effect size that would be required to distinguish true drug-induced changes from system variance in longitudinal trials. The sample consisted of 20 participants with PD and 19 HVs. Two independent teams analyzed the data to compare the volume of distribution calculated using image-derived input functions (IDIFs), and binding potentials calculated using the Logan reference region model. With all methods, the higher signal-to-background in patients resulted in lower variability and better repeatability than in controls. We were able to use noninvasive techniques showing significantly increased uptake of PK in multiple brain regions of participants with PD compared to HVs. Although not necessarily reflecting absolute values, these noninvasive image analysis methods can discriminate between PD patients and HVs. We see a difference of 24% in the substantia nigra between PD and HV with a repeatability coefficient of 13%, showing that it will be possible to estimate responses in longitudinal, within subject trials of novel neuroprotective drugs. © 2018 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.
Noninvasive differential diagnosis of dental periapical lesions in cone-beam CT scans.
Okada, Kazunori; Rysavy, Steven; Flores, Arturo; Linguraru, Marius George
2015-04-01
This paper proposes a novel application of computer-aided diagnosis (CAD) to an everyday clinical dental challenge: the noninvasive differential diagnosis of periapical lesions between periapical cysts and granulomas. A histological biopsy is the most reliable method currently available for this differential diagnosis; however, this invasive procedure prevents the lesions from healing noninvasively despite a report that they may heal without surgical treatment. A CAD using cone-beam computed tomography (CBCT) offers an alternative noninvasive diagnostic tool which helps to avoid potentially unnecessary surgery and to investigate the unknown healing process and rate for the lesions. The proposed semiautomatic solution combines graph-based random walks segmentation with machine learning-based boosted classifiers and offers a robust clinical tool with minimal user interaction. As part of this CAD framework, the authors provide two novel technical contributions: (1) probabilistic extension of the random walks segmentation with likelihood ratio test and (2) LDA-AdaBoost: a new integration of weighted linear discriminant analysis to AdaBoost. A dataset of 28 CBCT scans is used to validate the approach and compare it with other popular segmentation and classification methods. The results show the effectiveness of the proposed method with 94.1% correct classification rate and an improvement of the performance by comparison with the Simon's state-of-the-art method by 17.6%. The authors also compare classification performances with two independent ground-truth sets from the histopathology and CBCT diagnoses provided by endodontic experts. Experimental results of the authors show that the proposed CAD system behaves in clearer agreement with the CBCT ground-truth than with histopathology, supporting the Simon's conjecture that CBCT diagnosis can be as accurate as histopathology for differentiating the periapical lesions.
Baril, Patrick; Ezzine, Safia; Pichon, Chantal
2015-01-01
MicroRNAs (miRNAs) are a class of small non-coding RNAs that regulate gene expression by binding mRNA targets via sequence complementary inducing translational repression and/or mRNA degradation. A current challenge in the field of miRNA biology is to understand the functionality of miRNAs under physiopathological conditions. Recent evidence indicates that miRNA expression is more complex than simple regulation at the transcriptional level. MiRNAs undergo complex post-transcriptional regulations such miRNA processing, editing, accumulation and re-cycling within P-bodies. They are dynamically regulated and have a well-orchestrated spatiotemporal localization pattern. Real-time and spatio-temporal analyses of miRNA expression are difficult to evaluate and often underestimated. Therefore, important information connecting miRNA expression and function can be lost. Conventional miRNA profiling methods such as Northern blot, real-time PCR, microarray, in situ hybridization and deep sequencing continue to contribute to our knowledge of miRNA biology. However, these methods can seldom shed light on the spatiotemporal organization and function of miRNAs in real-time. Non-invasive molecular imaging methods have the potential to address these issues and are thus attracting increasing attention. This paper reviews the state-of-the-art of methods used to detect miRNAs and discusses their contribution in the emerging field of miRNA biology and therapy. PMID:25749473
Baril, Patrick; Ezzine, Safia; Pichon, Chantal
2015-03-04
MicroRNAs (miRNAs) are a class of small non-coding RNAs that regulate gene expression by binding mRNA targets via sequence complementary inducing translational repression and/or mRNA degradation. A current challenge in the field of miRNA biology is to understand the functionality of miRNAs under physiopathological conditions. Recent evidence indicates that miRNA expression is more complex than simple regulation at the transcriptional level. MiRNAs undergo complex post-transcriptional regulations such miRNA processing, editing, accumulation and re-cycling within P-bodies. They are dynamically regulated and have a well-orchestrated spatiotemporal localization pattern. Real-time and spatio-temporal analyses of miRNA expression are difficult to evaluate and often underestimated. Therefore, important information connecting miRNA expression and function can be lost. Conventional miRNA profiling methods such as Northern blot, real-time PCR, microarray, in situ hybridization and deep sequencing continue to contribute to our knowledge of miRNA biology. However, these methods can seldom shed light on the spatiotemporal organization and function of miRNAs in real-time. Non-invasive molecular imaging methods have the potential to address these issues and are thus attracting increasing attention. This paper reviews the state-of-the-art of methods used to detect miRNAs and discusses their contribution in the emerging field of miRNA biology and therapy.
An efficient and inexpensive method for measuring long-term thermoregulatory behavior
Sperry, Jinelle H.; Rohr, Jason R.
2016-01-01
Thermoregulatory ability and behavior influence organismal responses to their environment. By measuring thermal preferences, researchers can better understand the effects that temperature tolerances have on ecological and physiological responses to both biotic and abiotic stressors. However, because of funding limitations and confounders, measuring thermoregulation can often be difficult. Here, we provide an effective, affordable (∼$50 USD per unit), easy to construct, and validated apparatus for measuring the long-term thermal preferences of animals. In tests, the apparatus spanned temperatures from 9.29 to 33.94 °C, and we provide methods to further increase this range. Additionally, we provide simple methods to non-invasively measure animal and substrate temperatures and to prevent temperature preferences of the focal organisms from being confounded with temperature preferences of its prey and its humidity preferences. To validate the apparatus, we show that it was capable of detecting individual-level consistency and among individual-level variation in the preferred body temperatures of Southern toads (Anaxyrus terrestris) and Cuban tree frogs (Osteopilus septentrionalis) over three-weeks. Nearly every aspect of our design is adaptable to meet the needs of a multitude of study systems, including various terrestrial amphibious, and aquatic organisms. The apparatus and methods described here can be used to quantify behavioral thermal preferences, which can be critical for determining temperature tolerances across species and thus the resiliency of species to current and impending climate change. PMID:27503737
A novel patient-specific model to compute coronary fractional flow reserve.
Kwon, Soon-Sung; Chung, Eui-Chul; Park, Jin-Seo; Kim, Gook-Tae; Kim, Jun-Woo; Kim, Keun-Hong; Shin, Eun-Seok; Shim, Eun Bo
2014-09-01
The fractional flow reserve (FFR) is a widely used clinical index to evaluate the functional severity of coronary stenosis. A computer simulation method based on patients' computed tomography (CT) data is a plausible non-invasive approach for computing the FFR. This method can provide a detailed solution for the stenosed coronary hemodynamics by coupling computational fluid dynamics (CFD) with the lumped parameter model (LPM) of the cardiovascular system. In this work, we have implemented a simple computational method to compute the FFR. As this method uses only coronary arteries for the CFD model and includes only the LPM of the coronary vascular system, it provides simpler boundary conditions for the coronary geometry and is computationally more efficient than existing approaches. To test the efficacy of this method, we simulated a three-dimensional straight vessel using CFD coupled with the LPM. The computed results were compared with those of the LPM. To validate this method in terms of clinically realistic geometry, a patient-specific model of stenosed coronary arteries was constructed from CT images, and the computed FFR was compared with clinically measured results. We evaluated the effect of a model aorta on the computed FFR and compared this with a model without the aorta. Computationally, the model without the aorta was more efficient than that with the aorta, reducing the CPU time required for computing a cardiac cycle to 43.4%. Copyright © 2014. Published by Elsevier Ltd.
Kliemann, Dimas A; Wolff, Fernando H; Tovo, Cristiane V; Alencastro, Paulo R; Ikeda, Maria L R; Brandão, Ajácio B M; Barcellos, Nêmora; Fuchs, Sandra C
2016-01-01
The liver biopsy has been considered the gold standard for the diagnosis and quantification of fibrosis. However, this method presents limitations. In addition, the non-invasive evaluation of liver fibrosis is a challenge. The aim of this study was to validate the fibrosis cirrhosis index (FCI) index in a cohort of human immunodeficiency virus (HIV)/hepatitis C virus (HCV) coinfected patients, and compare to AST/ALT ratio (AAR), AST to platelet ratio index (APRI) and FIB-4 scores, as a tool for the assessment of liver fibrosis in coinfected patients. Retrospective cross sectional study including 92 HIV-HCV coinfected patients evaluated in two reference centers for HIV treatment in the Public Health System in Southern Brazil. Patients who underwent liver biopsy for any indication and had concomitant laboratory data in the 3 months prior to liver biopsy, to allow the calculation of studied noninvasive markers (AAR, APRI, FIB-4 and FCI) were included. APRI < 0.5 presents the higher specificity to detect no or minimal fibrosis, whereas APRI > 1.5 presents the best negative predictive value and FCI > 1.25 the best specificity to detect significant fibrosis. The values of noninvasive markers for each Metavir fibrosis stage showed statistically significant differences only for APRI. In conclusion, until better noninvasive markers for liver fibrosis are developed and validated for HIV-HCV coinfected patients, noninvasive serum markers should be used carefully in this population.
Comparison of non-invasive measures of cholinergic and allergic airway responsiveness in rats.
Glaab, T; Hecker, H; Stephan, M; Baelder, R; Braun, A; Korolewitz, R; Krug, N; Hoymann, H G
2006-04-01
Non-invasive analysis of tidal expiratory flow parameters such as Tme/TE (time needed to reach peak expiratory flow divided by total expiratory time) or midexpiratory tidal flow (EF50) has been shown useful for phenotypic characterization of lung function in humans and animal models. In this study, we aimed to compare the utility of two non-invasive measures, EF50 and Tme/TE, to monitor bronchoconstriction to inhaled cholinergic and allergic challenges in Brown-Norway rats. Non-invasive measurements of Tme/TE and EF50 were paralleled by invasive recordings of Tme/TE, EF50 and pulmonary conductance (GL). First, dose-response studies with acetylcholine were performed in naive rats, showing that EF50 better than Tme/TE reflected the dose-related changes as observed with the classical invasive outcome parameter GL. The subsequent determination of allergen-specific early airway responsiveness (EAR) showed that ovalbumin-sensitized and -challenged rats exhibited airway inflammation and allergen-specific EAR. Again, EF50 was more sensitive than Tme/TE in detecting the allergen-specific EAR recorded with invasive and non-invasive lung function methods and agreed well with classical GL measurements. We conclude that non-invasive assessment of EF50 is significantly superior to Tme/TE and serves as a suitable and valid tool for phenotypic screening of cholinergic and allergic airway responsiveness in rats.
Fouré, Alexandre
2016-01-01
The mechanical properties of tendon play a fundamental role to passively transmit forces from muscle to bone, withstand sudden stretches, and act as a mechanical buffer allowing the muscle to work more efficiently. The use of non-invasive imaging methods for the assessment of human tendon's mechanical, structural, and biochemical properties in vivo is relatively young in sports medicine, clinical practice, and basic science. Non-invasive assessment of the tendon properties may enhance the diagnosis of tendon injury and the characterization of recovery treatments. While ultrasonographic imaging is the most popular tool to assess the tendon's structural and indirectly, mechanical properties, ultrasonographic elastography, and ultra-high field magnetic resonance imaging (UHF MRI) have recently emerged as potentially powerful techniques to explore tendon tissues. This paper highlights some methodological cautions associated with conventional ultrasonography and perspectives for in vivo human Achilles tendon assessment using ultrasonographic elastography and UHF MRI. PMID:27512376
Near-infrared noninvasive spectroscopic determination of pH
Alam, Mary K.; Robinson, Mark R.
1998-08-11
Methods and apparatus for, preferably, determining noninvasively and in vitro pH in a human. The non-invasive method includes the steps of: generating light at three or more different wavelengths in the range of 1000 nm to 2500 nm; irradiating blood containing tissue; measuring the intensities of the wavelengths emerging from the blood containing tissue to obtain a set of at least three spectral intensities v. wavelengths; and determining the unknown values of pH. The determination of pH is made by using measured intensities at wavelengths that exhibit change in absorbance due to histidine titration. Histidine absorbance changes are due to titration by hydrogen ions. The determination of the unknown pH values is performed by at least one multivariate algorithm using two or more variables and at least one calibration model. The determined pH values are within the physiological ranges observed in blood containing tissue. The apparatus includes a tissue positioning device, a source, at least one detector, electronics, a microprocessor, memory, and apparatus for indicating the determined values.
Design of a novel noninvasive spectrometer for pesticide residues monitor
NASA Astrophysics Data System (ADS)
Ren, Zhong; Liu, Guodong; Huang, Zhen
2014-11-01
Although the gas or liquid chromatography had been widely used into pesticide residues monitoring, some drawbacks such as time-consuming, complicated operation and especially the destructivity for samples were existed. To overcome the limits of destructive detection methods, the noninvasive detection method based on spectroscopy was used to detect the pesticide residues in this paper. To overcome low resolution and light-efficiency due to the drawbacks of the classical plane and holography concave gratings, a novel noninvasive spectrometer for pesticide residues monitor (PRM) based on volume holography transmission (VHT) grating was designed. Meanwhile, a custom-built splitting light system for PRM based on the VHT grating was developed. In addition, the linear charge coupled device (CCD) with combined data acquisition (DAQ) card and the virtual-PRM based on LabVIEW were respectively used as the spectral acquisition hardware and software-platform. Experimental results showed that the spectral resolution of this spectrometer reached 2nm, and the VHT grating's diffraction efficiency was gotten via the simulation experiment.
NASA Astrophysics Data System (ADS)
Potapova, E. V.; Dremin, V. V.; Zherebtsov, E. A.; Makovik, I. N.; Zharkikh, E. V.; Dunaev, A. V.; Pilipenko, O. V.; Sidorov, V. V.; Krupatkin, A. I.
2017-12-01
The possibility of a complex approach for studying changes in the system of blood microcirculation and metabolic processes in the biotissue of lower extremities using optical noninvasive methods of laser doppler flowmetry (LDF), fluorescence spectroscopy, and diffuse reflectance spectroscopy in combination with different modes of heating tests has been assessed. Seventy-six patients with type 2 diabetes mellitus, with 14 patients having visible trophic foot impairments, and 48 healthy volunteers have been examined. The parameters of LDF signals and spectra of fluorescence intensity and diffuse reflectance for foot skin have been analyzed. Statistically significant differences in the recorded parameters between the groups under study have been found. It has been concluded that combined application of noninvasive methods of spectroscopy could be used for diagnostics of complications both upon the occurrence of preliminary symptoms of diabetes, when pathological changes are still reversible, and in the presence of impairments to prevent aggravation of the disease and select an adequate correction of the treatment.
Hennig, Georg; Homann, Christian; Teksan, Ilknur; Hasbargen, Uwe; Hasmüller, Stephan; Holdt, Lesca M.; Khaled, Nadia; Sroka, Ronald; Stauch, Thomas; Stepp, Herbert; Vogeser, Michael; Brittenham, Gary M.
2016-01-01
Worldwide, more individuals have iron deficiency than any other health problem. Most of those affected are unaware of their lack of iron, in part because detection of iron deficiency has required a blood sample. Here we report a non-invasive method to optically measure an established indicator of iron status, red blood cell zinc protoporphyrin, in the microcirculation of the lower lip. An optical fibre probe is used to illuminate the lip and acquire fluorescence emission spectra in ∼1 min. Dual-wavelength excitation with spectral fitting is used to distinguish the faint zinc protoporphyrin fluorescence from the much greater tissue background fluorescence, providing immediate results. In 56 women, 35 of whom were iron-deficient, the sensitivity and specificity of optical non-invasive detection of iron deficiency were 97% and 90%, respectively. This fluorescence method potentially provides a rapid, easy to use means for point-of-care screening for iron deficiency in resource-limited settings lacking laboratory infrastructure. PMID:26883939