Sample records for simple payback analysis

  1. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  2. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  3. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  4. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  5. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  6. Payback as an investment criterion for sawmill improvement projects

    Treesearch

    G. B. Harpole

    1983-01-01

    Methods other than presented here should be used to assess projects for likely return on investment; but, payback is simple to calculate and can be used for calculations that will indicate the relative attractiveness of alternative improvement projects. This paper illustrates how payback ratios are calculated, how they can be used to rank alternative improvement...

  7. Water Conservation Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ian Metzger, Jesse Dean

    2010-12-31

    This software requires inputs of simple water fixture inventory information and calculates the water/energy and cost benefits of various retrofit opportunities. This tool includes water conservation measures for: Low-flow Toilets, Low-flow Urinals, Low-flow Faucets, and Low-flow Showheads. This tool calculates water savings, energy savings, demand reduction, cost savings, and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

  8. Comparing energy payback and simple payback period for solar photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Kessler, Will

    2017-11-01

    Installing a solar photovoltaic (PV) array is both an environmental and a financial decision. The financial arguments often take priority over the environmental because installing solar is capital-intensive. The Simple Payback period (SPB) is often assessed prior to the adoption of solar PV at a residence or a business. Although it better describes the value of solar PV electricity in terms of sustainability, the Energy Payback period (EPB) is seldom used to gauge the merits of an installation. Using published estimates of embodied energies, EPB was calculated for four solar PV plants utilizing crystalline-Si technology: three being actual commercial installations located in the northeastern U.S., and a fourth installation based on a simulated 20-kilowatt roof-mounted system, in Wrocław, Poland. Simple Payback was calculated based on initial capital cost, and on the availability of avoided electricity costs based on net-metering tariffs, which at present in the U.S. are 1:1 credit ratio, and in Poland is 1:0.7 credit ratio. For all projects, the EPB time was estimated at between 1.9 and 2.6 years. In contrast, the SPB for installed systems in the northeastern U.S. ranged from 13.3 to 14.6 years, and was estimated at 13.5 years for the example system in Lower Silesia, Poland. The comparison between SPB and EPB shows a disparity between motivational time frames, in which the wait for financial return is considerably longer than the wait for net energy harvest and the start of sustainable power production.

  9. A cost–benefit analysis of acclimation to low irradiance in tropical rainforest tree seedlings: leaf life span and payback time for leaf deployment

    PubMed Central

    Coste, Sabrina; Roggy, Jean-Christophe; Schimann, Heidy; Epron, Daniel; Dreyer, Erwin

    2011-01-01

    The maintenance in the long run of a positive carbon balance under very low irradiance is a prerequisite for survival of tree seedlings below the canopy or in small gaps in a tropical rainforest. To provide a quantitative basis for this assumption, experiments were carried out to determine whether construction cost (CC) and payback time for leaves and support structures, as well as leaf life span (i) differ among species and (ii) display an irradiance-elicited plasticity. Experiments were also conducted to determine whether leaf life span correlates to CC and payback time and is close to the optimal longevity derived from an optimization model. Saplings from 13 tropical tree species were grown under three levels of irradiance. Specific-CC was computed, as well as CC scaled to leaf area at the metamer level. Photosynthesis was recorded over the leaf life span. Payback time was derived from CC and a simple photosynthesis model. Specific-CC displayed only little interspecific variability and irradiance-elicited plasticity, in contrast to CC scaled to leaf area. Leaf life span ranged from 4 months to >26 months among species, and was longest in seedlings grown under lowest irradiance. It was always much longer than payback time, even under the lowest irradiance. Leaves were shed when their photosynthesis had reached very low values, in contrast to what was predicted by an optimality model. The species ranking for the different traits was stable across irradiance treatments. The two pioneer species always displayed the smallest CC, leaf life span, and payback time. All species displayed a similar large irradiance-elicited plasticity. PMID:21511904

  10. Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  11. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency watermore » heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  12. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  13. 77 FR 7281 - Energy Conservation Program: Energy Conservation Standards for Distribution Transformers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... Manufacturing Transformers H. Customer Subgroup Analysis I. Manufacturer Impact Analysis 1. Overview 2... Justification and Energy Savings 1. Economic Impacts on Customers a. Life-Cycle Cost and Payback Period b. Customer Subgroup Analysis c. Rebuttable-Presumption Payback 2. Economic Impact on Manufacturers a...

  14. Comparative economics of space resource utilization

    NASA Technical Reports Server (NTRS)

    Cutler, Andrew Hall

    1991-01-01

    Physical economic factors such as mass payback ratio, total payback ratio, and capital payback time are discussed and used to compare the economics of using resources from the Moon, Mars and its moons, and near Earth asteroids to serve certain near term markets such as propellant in low Earth orbit or launched mass reduction for lunar and Martian exploration. Methods for accounting for the time cost of money in simple figures of merit such as MPRs are explored and applied to comparisons such as those between lunar, Martian, and asteroidal resources. Methods for trading off capital and operating costs to compare schemes with substantially different capital to operating cost ratio are presented and discussed. Areas where further research or engineering would be extremely useful in reducing economic uncertainty are identified, as are areas where economic merit is highly sensitive to engineering performance - as well as areas where such sensitivity is surprisingly low.

  15. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  16. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  17. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  18. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  19. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  20. Energy survey study and report of hospitals in Chicago: South Suburban Hospital: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-08-01

    This study is part of a three-phased demonstration project to reduce energy consumption in hospitals through practical life-cycle/cost-effective modifications and alteration. Funds for the demonstration project are provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). A thorough study and evaluation of all building systems is made to identify opportunities for reduction in energy consumption and to determine the most cost effective approaches to energy conservation. The primary objective of the study is to investigate and analyze energy usage of the facility and to identify all life cycle,more » cost-effective changes required to effect a reduction in energy consumption. For the purpose of economic evaluation of the energy conservation projects identified, life-cycle cost and simple payback periods are used. Energy conservation measures with simple payback periods exceeding five years were dismissed from further detailed study.« less

  1. 10 CFR 455.63 - Cost-effectiveness testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The simple payback period of each energy conservation measure (except measures to shift demand, or...), by the estimated annual cost savings accruing from the measure (adjusted for demand charges), as... non-renewable fuels displaced less the annual cost of the renewable fuel, if any, and the annual cost...

  2. 10 CFR 455.63 - Cost-effectiveness testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) The simple payback period of each energy conservation measure (except measures to shift demand, or...), by the estimated annual cost savings accruing from the measure (adjusted for demand charges), as... non-renewable fuels displaced less the annual cost of the renewable fuel, if any, and the annual cost...

  3. 7 CFR 4288.21 - Application review and scoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...

  4. 7 CFR 4288.21 - Application review and scoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...

  5. 7 CFR 4288.21 - Application review and scoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...

  6. Ambulatory electronic medical record payback analysis 7 years after implementation in a tertiary care county medical system.

    PubMed

    Kaelber, David C; Miller, Vince; Fisher, Nancy; Schlesinger, Jim; Norris, Greg

    2007-10-11

    Electronic medical records (EMRs) are gaining increasing prominence in healthcare, however still have low market penetration. EMR implementation cost is a primary perceived barrier. Here we present a payback analysis on an outpatient EMR implementation, showing capital expense recovery (net of operating costs) at 6 years and now generating $6 million yearly in direct savings for our healthcare system.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, W.N.

    This report summarizes measured performance of residential geothermal heat pumps (GHP`s) that were installed in family housing units at Ft. Hood, Texas and at Selfridge Air National Guard base in Michigan. These units were built as part of a joint Department of Defense/Department of Energy program to evaluate the energy savings potential of GHP`s installed at military facilities. At the Ft. Hood site, the GHP performance was compared to conventional forced air electric air conditioning and natural gas heating. At Selfridge, the homes under test were originally equipped with electric baseboard heat and no air conditioning. Installation of the GHPmore » systems at both sites was straightforward but more problems and costs were incurred at Selfridge because of the need to install ductwork in the homes. The GHP`s at both sites produced impressive energy savings. These savings approached 40% for most of the homes tested. The low cost of energy on these bases relative to the incremental cost of the GHP conversions precludes rapid payback of the GHP`s from energy savings alone. Estimates based on simple payback (no inflation and no interest on capital) indicated payback times from 15 to 20 years at both sites. These payback times may be reduced by considering the additional savings possible due to reduced maintenance costs. Results are summarized in terms of 15 minute, hourly, monthly, and annual performance parameters. The results indicate that all the systems were working properly but several design shortcomings were identified. Recommendations are made for improvements in future installations at both sites.« less

  8. Energy Assessment Helps Kaiser Aluminum Save Energy and Improve Productivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2008-07-01

    The Kaiser Aluminum plant in Sherman, Texas, adjusted controls and made repairs to a furnace for a simple payback of 1 month. Kaiser adopted DOE's Process Heating Assessment and Survey Tool (PHAST) software as the corporate diagnostic tool and has used it to evaluate process heating systems at five other aluminum plants.

  9. 34 CFR 263.10 - What are the payback reporting requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for payments. (Approved by the Office of Management and Budget under control number 1810-0580... notice of intent to complete a work-related or cash payback, or to continue in a degree program as a full..., but cannot complete, a work-related payback, the payback reverts to a cash payback that is prorated...

  10. Camp Pendleton Saves 91% in Parking Lot Lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-01-01

    Case study describes how Camp Pendleton Marine Corps Base replaced high-pressure sodium (HPS) fixtures in one parking lot with high-efficiency induction fixtures for 91% savings in energy use and $5,700 in cost savings annually. This parking lot is estimated to have a simple payback of 2.9 years. Sitewide up-grades yielded annual savings of 1 million kWh.

  11. Sand Filter Technology

    DTIC Science & Technology

    2016-08-01

    Approved for public release: distribution unlimited TDS-NAVFAC-EXWC-PW-1604 Aug 2016 Sand Filter Technology This report summarizes the...findings from a demonstration of sand filter technology to determine whether the technology will save energy with a simple payback within the...EXWC) performed the evaluation at the Naval Air Station Lemoore, CA. The two year evaluation period began with one year of sand filter operation

  12. Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Geoffrey C.; Federspiel, Clifford

    Control software and wireless sensors designed for closed-loop, monitoring and control of IT equipment's inlet air temperatures in datacenters were evaluated and tested while other datacenter cooling best practices were implemented. The controls software and hardware along with each best practice were installed sequentially and evaluated using a measurement and verification procedure between each measure. The results show that the overall project eliminates 475,239 kWh per year, which is 21.3percent of the baseline energy consumption of the data center. The total project, including the best practices will save $42,772 per year and cost $134,057 yielding a simple payback of 3.1more » years. However, the control system alone eliminates 59.6percent of the baseline energy used to move air in the datacenter and 13.6percent of the baseline cooling energy, which is 15.2percent of the baseline energy consumption (see Project Approach, Task 1, below, for additional information) while keeping temperatures substantially within the limits recommended by ASHRAE. Savings attributed to the control system are $30,564 per year with a cost $56,824 for a simple payback of 1.9 years.« less

  13. An analysis of switching and non-switching slot machine player behaviour.

    PubMed

    Coates, Ewan; Blaszczynski, Alex

    2013-12-01

    Learning theory predicts that, given the repeated choice to bet between two concurrently available slot machines, gamblers will learn to bet more money on the machine with higher expected return (payback percentage) or higher win probability per spin (volatility). The purpose of this study was to investigate whether this occurs when the two machines vary orthogonally on payback percentage and volatility. The sample comprised 52 first year psychology students (mean age = 20.3 years, 20 females, 32 males) who had played a gaming machine at least once in the previous 12 months. Participants were administered a battery of questionnaires designed to assess level of knowledge on the characteristics and operation of poker machines, frequency of poker machine play in the past 12 months, personality traits of impulsivity and capacity for cognitive reflection, and gambling beliefs. For the experimental task, participants were instructed to play on two PC-simulated electronic gaming machines (EGMs or slot machines) that differed on payback percentage and volatility, with the option of freely switching between EGMs after a practice phase. Results indicated that participants were able to easily discriminate between machines and manifested a preference to play machines offering higher payback or volatility. These findings diverged from previous findings of no preference for play on higher payback/volatility machines, potentially due to of the current study's absence of the option to make multi-line and multi-credit bets. It was concluded that return rate parameters like payback percentage and volatility strongly influenced slot machine preference in the absence of betting options like multi-line bets, though more research is needed to determine the effects of such betting options on player distribution of money between multiple EGMs.

  14. Army Reserve 63d RSC Achieves 85% Savings in Parking Lot Lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Case study describes how the Army Reserve 63d Regional Support Command (RSC) achieved 85% energy savings and $4,000 per year in cost savings by replacing 12 old light fixtures with light-emitting diode fixtures in the military equipment parking area. This project was part of a camp-wide parking lighting retrofit which, on average, delivered 78% energy savings and a simple payback of 4.4 years.

  15. Implementing a resident lifting system in an extended care hospital. Demonstrating cost-benefit.

    PubMed

    Spiegel, Jerry; Yassi, Analee; Ronald, Lisa A; Tate, Robert B; Hacking, Penny; Colby, Teresa

    2002-03-01

    1. Implemeting mechanical resident lifting equipment in an extended care facility produced a payback from direct savings alone within 4 years. Payback occurred more quickly when the effect of indirect savings or the trend to rising compensation costs was considered. 2. Combining the observations of the occupational health nurses related to staff well being with relevant cost-benefit data is useful in influencing decision makers and in securing funding for prevention measures. 3. Clear identification of a viewpoint is an important part of an economic evaluation and cost-benefit analysis.

  16. A Greenhouse Gas and Soil Carbon Model for Estimating the Carbon Footprint of Livestock Production in Canada

    PubMed Central

    Vergé, Xavier P.C.; Dyer, James A.; Worth, Devon E.; Smith, Ward N.; Desjardins, Raymond L.; McConkey, Brian G.

    2012-01-01

    Simple Summary We developed a model to estimate the carbon footprint of Canadian livestock production. To include long term soil carbon storage and loss potential we introduced a payback period concept. The model was tested by reallocating 10% only of the protein production from a ruminant to a non ruminant source to minimize the risk of including rangeland or marginal lands. This displacement generated residual land which was found to play a major role in the potential mitigation of GHG emissions. The model will allow land use policies aimed at reducing the agricultural GHG emissions to be assessed. Abstract To assess tradeoffs between environmental sustainability and changes in food production on agricultural land in Canada the Unified Livestock Industry and Crop Emissions Estimation System (ULICEES) was developed. It incorporates four livestock specific GHG assessments in a single model. To demonstrate the application of ULICEES, 10% of beef cattle protein production was assumed to be displaced with an equivalent amount of pork protein. Without accounting for the loss of soil carbon, this 10% shift reduced GHG emissions by 2.5 TgCO2e y−1. The payback period was defined as the number of years required for a GHG reduction to equal soil carbon lost from the associated land use shift. A payback period that is shorter than 40 years represents a net long term decrease in GHG emissions. Displacing beef cattle with hogs resulted in a surplus area of forage. When this residual land was left in ungrazed perennial forage, the payback periods were less than 4 years and when it was reseeded to annual crops, they were equal to or less than 40 years. They were generally greater than 40 years when this land was used to raise cattle. Agricultural GHG mitigation policies will inevitably involve a trade-off between production, land use and GHG emission reduction. ULICEES is a model that can objectively assess these trade-offs for Canadian agriculture. PMID:26487032

  17. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  18. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  19. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  20. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  1. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  2. 34 CFR 263.9 - When does payback begin?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false When does payback begin? 263.9 Section 263.9 Education Regulations of the Offices of the Department of Education OFFICE OF ELEMENTARY AND SECONDARY EDUCATION, DEPARTMENT OF EDUCATION INDIAN EDUCATION DISCRETIONARY GRANT PROGRAMS Professional Development Program § 263.9 When does payback begin? (a) For...

  3. An investigation into the potential of low head hydro power in Northern Ireland for the production of electricity

    NASA Astrophysics Data System (ADS)

    Redpath, David; Ward, Michael J.

    2017-07-01

    The maximum exploitable potential for low head hydroelectric sites (gross head≤10 m) in Northern Ireland (NI) was determined as 12.07 MW using a simple payback analysis for 304 potential sites investigated to derive a classification scheme in terms of economic viability. A techno-economic analysis with validated numerical models from previous research estimated the capital investment required for the development of a hydroelectric plant, using the low head Michell-Banki cross flow turbine, for the 304 sites investigated. The number of potentially viable sites in NI for low head hydro ranged from 198 to 286 with an estimated installed capacity ranging from 11.95 to 12.05 MW. Sites with a limited installed capacity were not economically viable unless increased government support in the form of longer term (25-50 years) low interest loans as well as the current (Renewables Obligations Certificates) Renewables Obligation Certificates scheme is provided and sustained.

  4. Design and construction evaluation of a photovoltaic DC LED lighting system

    NASA Astrophysics Data System (ADS)

    Bhamidipati, Jyotsna

    2008-08-01

    The market demand for commercialization of Photovoltaic (PV) systems depends a lot on the reliability, efficiency and performance of various components within the system. PV panels produce DC power when exposed to sunlight, and an inverter converts this to AC power in a typical solar powered building. Though, PV lighting has existed for a long time it hasn't been very effective, as incandescent light sources were commonly used which are inefficient. Today fluorescent fixtures are mostly used with PV's due to its high efficacy. Light-emitting diodes present a new vision to energy efficiency in lighting design with their low energy consumption. Current research predicts improved efficiencies of LED light fixtures and their commercial use is a few years away. LEDs which operate on DC voltages when coupled with photovoltaics can be a simple PV lighting application and a sustainable solution with potential for payback. This research evaluates the design and construction of a photovoltaic DC LED lighting system for a solar house at Pennsylvania State University. A detailed cost and payback analysis of a PV DC LED lighting system is presented in this research. PV output simulations for the solar house are presented. Results presented in this research indicate that the Solid state lighting market is evolving rapidly and that LED's are a choice in stand-alone photovoltaic DC lighting systems. The efficiency and the cost-effectiveness of such systems would however improve in the coming years with research and development now focused on PV systems and on Solid state lighting technologies.

  5. Science and society test VI: Energy economics

    NASA Astrophysics Data System (ADS)

    Hafemeister, David W.

    1982-01-01

    Simple numerical estimates are developed in order to quantify a variety of energy economics issues. The Verhulst equation, which considers the effect of finite resources on petroleum production, is modified to take into account supply and demand economics. Numerical and analytical solutions to these differential equations are presented in terms of supply and demand elasticity functions, various finite resources, and the rate of increase in fuel costs. The indirect cost per barrel of imported oil from OPEC is shown to be about the same as the direct cost. These effects, as well as those of discounted benefits and deregulation, are used in a calculation of payback periods for various energy conserving devices. A phenomenological model for market penetration is developed along with the factors for future energy growth rates. A brief analysis of the economic returns of the ''house doctor'' program to reprofit houses for energy conservation is presented.

  6. JT8D and JT9D jet engine performance improvement program. Task 1: Feasibility analysis

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.; Webb, D. E.

    1979-01-01

    JT8D and JT9D component performance improvement concepts which have a high probability of incorporation into production engines were identified and ranked. An evaluation method based on airline payback period was developed for the purpose of identifying the most promising concepts. The method used available test data and analytical models along with conceptual/preliminary designs to predict the performance improvements, weight, installation characteristics, cost for new production and retrofit, maintenance cost, and qualitative characteristics of candidate concepts. These results were used to arrive at the concept payback period, which is the time required for an airline to recover the investment cost of concept implementation.

  7. Predictors of return rate discrimination in slot machine play.

    PubMed

    Coates, Ewan; Blaszczynski, Alex

    2014-09-01

    The purpose of this study was to investigate the extent to which accurate estimates of payback percentages and volatility combined with prior learning, enabled players to successfully discriminate between multi-line/multi-credit slot machines that provided differing rates of reinforcement. The aim was to determine if the capacity to discriminate structural characteristics of gaming machines influenced player choices in selecting 'favourite' slot machines. Slot machine gambling history, gambling beliefs and knowledge, impulsivity, illusions of control, and problem solving style were assessed in a sample of 48 first year undergraduate psychology students. Participants were subsequently exposed to a choice paradigm where they could freely select to play either of two concurrently presented PC-simulated slot machines programmed to randomly differ in expected player return rates (payback percentage) and win frequency (volatility). Results suggest that prior learning and cognitions (particularly gambler's fallacy) but not payback, were major contributors to the ability of a player to discriminate volatility between slot machines. Participants displayed a general tendency to discriminate payback, but counter-intuitively placed more bets on the slot machine with lower payback percentage rates.

  8. How can payback from health services research be assessed?

    PubMed

    Buxton, M; Hanney, S

    1996-01-01

    Throughout the world there is a growing recognition that health care should be research-led. This strengthens the requirement for expenditure on health services research to be justified by demonstrating the benefits it produces. However, payback from health research and development is a complex concept and little used term. Five main categories of payback can be identified: knowledge; research benefits; political and administrative benefits; health sector benefits; and broader economic benefits. Various models of research utilization together with previous assessments of payback from research helped in the development of a new conceptual model of how and where payback may occur. The model combines an input-output perspective with an examination of the permeable interfaces between research and its environment. The model characterizes research projects in terms of Inputs, Processes, and Primary Outputs. The last consist of knowledge and research benefits. There are two interfaces between the project and its environment. The first (Project Specification, Selection and Commissioning) is the link with Research Needs Assessment. The second (Dissemination) should lead to Secondary Outputs (which are policy or administrative decisions), and usually Applications (which take the form of behavioural changes), from which Impacts or Final Outcomes result. It is at this final stage that health and wider economic benefits can be measured. A series of case studies were used to assess the feasibility both of applying the model and the payback categorization. The paper draws various conclusions from the case studies and identifies a range of issues for further work.

  9. Profitability Analysis of Soybean Oil Processes.

    PubMed

    Cheng, Ming-Hsun; Rosentrater, Kurt A

    2017-10-07

    Soybean oil production is the basic process for soybean applications. Cash flow analysis is used to estimate the profitability of a manufacturing venture. Besides capital investments, operating costs, and revenues, the interest rate is the factor to estimate the net present value (NPV), break-even points, and payback time; which are benchmarks for profitability evaluation. The positive NPV and reasonable payback time represent a profitable process, and provide an acceptable projection for real operating. Additionally, the capacity of the process is another critical factor. The extruding-expelling process and hexane extraction are the two typical approaches used in industry. When the capacities of annual oil production are larger than 12 and 173 million kg respectively, these two processes are profitable. The solvent free approach, known as enzyme assisted aqueous extraction process (EAEP), is profitable when the capacity is larger than 17 million kg of annual oil production.

  10. Profitability Analysis of Soybean Oil Processes

    PubMed Central

    2017-01-01

    Soybean oil production is the basic process for soybean applications. Cash flow analysis is used to estimate the profitability of a manufacturing venture. Besides capital investments, operating costs, and revenues, the interest rate is the factor to estimate the net present value (NPV), break-even points, and payback time; which are benchmarks for profitability evaluation. The positive NPV and reasonable payback time represent a profitable process, and provide an acceptable projection for real operating. Additionally, the capacity of the process is another critical factor. The extruding-expelling process and hexane extraction are the two typical approaches used in industry. When the capacities of annual oil production are larger than 12 and 173 million kg respectively, these two processes are profitable. The solvent free approach, known as enzyme assisted aqueous extraction process (EAEP), is profitable when the capacity is larger than 17 million kg of annual oil production. PMID:28991168

  11. Techno-economic analysis of lipase enzyme production from agro-industry waste with solid state fermentation method

    NASA Astrophysics Data System (ADS)

    Hidayatullah, I. M.; Arbianti, R.; Utami, T. S.; Suci, M.; Sahlan, M.; Wijanarko, A.; Gozan, M.; Hermansyah, H.

    2018-03-01

    Needs for this kind of catalyst derived from biological raw materials (biocatalysts) has increased along with development of products based on eco-friendly. To achieve the needs of biocatalyst (enzyme), large production is necessary. This study aimed to get the best conditions and design equipment to produce lipase enzyme based on solid state fermentation using SuperPro Designer v9.0. Several equipment such as Tray Bioreactor, Mixing Tank 1, Filter Press, centrifuge, Mixing Tank 2, and a dryer have been improved during the simulation. Economic analysis in the form of NPV, IRR, Payback Period, and the Benefit Cost Ratio was evaluated respectively. The result showed that production of 10 kg enzyme with NPV Rp112.796.147.423,00; IRR 54.20%; Payback Period 1.95 years; and Benefit Cost Ratio of 3.36 was more advantageous.

  12. Solar breeder: Energy payback time for silicon photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Lindmayer, J.

    1977-01-01

    The energy expenditures of the prevailing manufacturing technology of terrestrial photovoltaic cells and panels were evaluated, including silicon reduction, silicon refinement, crystal growth, cell processing and panel building. Energy expenditures include direct energy, indirect energy, and energy in the form of equipment and overhead expenses. Payback times were development using a conventional solar cell as a test vehicle which allows for the comparison of its energy generating capability with the energies expended during the production process. It was found that the energy payback time for a typical solar panel produced by the prevailing technology is 6.4 years. Furthermore, this value drops to 3.8 years under more favorable conditions. Moreover, since the major energy use reductions in terrestrial manufacturing have occurred in cell processing, this payback time directly illustrates the areas where major future energy reductions can be made -- silicon refinement, crystal growth, and panel building.

  13. Resource engineering and economic studies for direct application of geothermal energy. Draft final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-12-01

    The feasibility of utilizing geothermal energy at a selected plant in New York State was studied. Existing oil and gas records suggests that geothermal fluid is available in the target area and based on this potential. Friendship Dairies, Inc., Friendship, NY, was selected as a potential user of geothermal energy. Currently natural gas and electricity are used as its primary energy sources. Six geothermal system configurations were analyzed based on replacement of gas or oil-fired systems for producing process heat. Each system was evaluated in terms of Internal Rate of Return on Investment (IRR), and simple payback. Six system configurationsmore » and two replaced fuels, representative of a range of situations found in the state, are analyzed. Based on the potential geothermal reserves at Friendship, each of the six system configurations are shown to be economically viable, compared to continued gas or oil-firing. The Computed IRR's are all far in excess of projected average interest rates for long term borrowings: approximately 15% for guarantee backed loans or as high as 20% for conventional financing. IRR is computed based on the total investment (equity plus debt) and cash flows before financing costs, i.e., before interest expense, but after the tax benefit of the interest deduction. The base case application for the Friendship analysis is case B/20 yr-gas which produces an IRR of 28.5% and payback of 3.4 years. Even better returns could be realized in the cases of oil-avoidance and where greater use of geothermal energy can be made as shown in the other cases considered.« less

  14. Development of an Enhanced Payback Function for the Superior Energy Performance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Therkelsen, Peter; Rao, Prakash; McKane, Aimee

    2015-08-03

    The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This papermore » analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.« less

  15. Financial Analysis: A Review of the Methods and Their Application to Employee Training. Training and Development Research Center Project Number Nine.

    ERIC Educational Resources Information Center

    Mosier, Nancy R.

    Financial analysis techniques are tools that help managers make sound financial decisions that contribute to general corporate objectives. A literature review reveals that the most commonly used financial analysis techniques are payback time, average rate of return, present value or present worth, and internal rate of return. Despite the success…

  16. Mixing Appropriations and Private Financing to Meet Federal Energy Management Goals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shonder, John A

    2012-06-01

    This report compares several strategies for mixing appropriations and private financing in a typical federal agency that has identified $100 million in required energy conservation measures (ECMs) at its facilities. The analysis shows that in order to maximize savings and minimize overall life-cycle cost, the best strategy for the agency is to use private financing to fund as many of the ECMs as possible within the statutory maximum 25-year project term, beginning with the ECMs with the shortest paybacks. Available appropriations should either be applied to a privately financed project as a one-time payment from savings (i.e., as a buydownmore » ) or used to directly fund longer-payback ECMs that cannot be included in the privately financed project.« less

  17. 34 CFR 263.9 - When does payback begin?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF EDUCATION INDIAN EDUCATION DISCRETIONARY GRANT PROGRAMS Professional Development Program § 263... Professional Development program, payback shall begin within six months from the date of completion of the training. (b) For participants who do not complete their training under the Professional Development...

  18. 78 FR 13566 - Energy Conservation Program for High-Intensity Discharge Lamps: Public Meeting and Availability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... Prices C. Energy Use Analysis D. Life-Cycle Cost and Payback Period Analyses E. National Impact Analysis... projected energy prices and installed stock in each year. DOE calculates annual equipment expenditures by... DEPARTMENT OF ENERGY 10 CFR Part 431 [Docket No. EERE-2010-BT-STD-0043] RIN 1904-AC36 Energy...

  19. An economic analysis comparison of stationary and dual-axis tracking grid-connected photovoltaic systems in the US Upper Midwest

    NASA Astrophysics Data System (ADS)

    Choi, Wongyu; Pate, Michael B.; Warren, Ryan D.; Nelson, Ron M.

    2018-05-01

    This paper presents an economic analysis of stationary and dual-axis tracking photovoltaic (PV) systems installed in the US Upper Midwest in terms of life-cycle costs, payback period, internal rate of return, and the incremental cost of solar energy. The first-year performance and energy savings were experimentally found along with documented initial cost. Future PV performance, savings, and operating and maintenance costs were estimated over 25-year assumed life. Under the given assumptions and discount rates, the life-cycle savings were found to be negative. Neither system was found to have payback periods less than the assumed system life. The lifetime average incremental costs of energy generated by the stationary and dual-axis tracking systems were estimated to be 0.31 and 0.37 per kWh generated, respectively. Economic analyses of different scenarios, each having a unique set of assumptions for costs and metering, showed a potential for economic feasibility under certain conditions when compared to alternative investments with assumed yields.

  20. Congeneration feasibility: Otis Elavator Company and Polychrome Corporation

    NASA Astrophysics Data System (ADS)

    Fox, H.

    1982-05-01

    An investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY is discussed. Existing electrical and steam producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return on investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, this detailed study provides valuable insights.

  1. Techno-Economic analysis of solar photovoltaic power plant for small scale fish processing in Kota Langsa - a case study

    NASA Astrophysics Data System (ADS)

    Widodo, S. B.; Hamdani; Rizal, T. A.; Pambudi, N. A.

    2018-02-01

    In Langsa, fisheries are the sector leaders by fulfilling a capacity of about 6,050 tons per year and on the other hand, fish-aquaculture reaches 1,200 tons per year on average. The fish processing is conducted through catches and aquaculture. The facilities on which this processing takes place are divided into an ice factory unit, a gutting and cutting unit, a drying unit and a curing unit. However, the energy and electricity costs during the production process has become major constraint because of the increase in the fishermen’s production and income. In this study, the potential and cost-effectiveness of photovoltaic solar power plant to meet the energy demands of fish processing units have been analysed. The energy requirements of fish processing units have reached an estimate of 130 kW, while the proposed design of solar photovoltaic electricity generation is of 200 kW in an area of 0,75 hectares. In this analysis, given the closeness between the location of the processing units and the fish supply auctions, the assumption is made that the photovoltaic plants (OTR) were installed on the roof of the building as compared to the solar power plants (OTL) installed on the outside of the location. The results shows that the levelized cost of OTR instalation is IDR 1.115 per kWh, considering 25 years of plant life-span at 10% of discount rate, with a simple payback period of 13.2 years. OTL levelized energy, on the other hand, is at IDR 997.5 per kWh with a simple payback period of 9.6 years. Blood is an essential component of living creatures in the vascular space. For possible disease identification, it can be tested through a blood test, one of which can be seen from the form of red blood cells. The normal and abnormal morphology of the red blood cells of a patient is very helpful to doctors in detecting a disease. With the advancement of digital image processing technology can be used to identify normal and abnormal blood cells of a patient. This research used self-organizing map method to classify the normal and abnormal form of red blood cells in the digital image. The use of self-organizing map neural network method can be implemented to classify the normal and abnormal form of red blood cells in the input image with 93,78% accuracy testing.

  2. Lighting Control Systems

    DTIC Science & Technology

    2004-02-26

    Shorter payback periods After 19 Cost Benefit of Powerlink Rule of Thumb for Powerlink: Powerlink becomes more cost effective beyond 16 controlled...web enabled control (and management software) Increase in level of integration between building systems Increase in new features, functions, benefits ...focus on reducing run-time via Scheduling, Sensing, Switching Growing focus on payback Direct energy cost (with demand) Additional maintenance benefits

  3. The relationship between reinforcement and gaming machine choice.

    PubMed

    Haw, John

    2008-03-01

    The present study assessed whether prior reinforcement experiences were related to gaming machine choice and the decision to change gaming machines during a session of gambling. Seventy undergraduate students (48 women, 22 men; mean age = 22.05 years) were presented with two visually identical simulated gaming machines in a practice phase. These simulated machines differed only in the rate of reinforcement. After the practice phase, participants were asked to choose a machine to play in the test phase and were allowed to change machines at will. Two measures of reinforcement were employed; frequency of wins and payback rate. Results indicated that neither measure of reinforcement was related to machine choice, but both were predictors of when participants changed machines. A post-hoc analysis of the 33 participants who changed machines during the test phase found a significant relationship between machine choice and prior reinforcement. For these participants, payback rate was significantly related to machine choice, unlike frequency of wins.

  4. Demonstration Assessment of Light Emitting Diode (LED) Walkway Lighting at the Federal Aviation Administration William J. Hughes Technical Center, in Atlantic City, New Jersey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    This report documents the results of a collaborative project to demonstrate a solid state lighting (SSL) general illumination product in an outdoor area walkway application. In the project, six light-emitting diode (LED) luminaires were installed to replace six existing high pressure sodium (HPS) luminaires mounted on 14-foot poles on a set of exterior walkways and stairs at the Federal Aviation Administration (FAA) William J. Hughes Technical Center in Atlantic City, New Jersey, during December, 2007. The effort was a U.S. Department of Energy (DOE) SSL Technology Gateway Demonstration that involved a collaborative teaming agreement between DOE, FAA and Ruud Lightingmore » (and their wholly owned division, Beta LED). Pre- and post-installation power and illumination measurements were taken and used in calculations of energy savings and related economic payback, while personnel impacted by the new lights were provided questionnaires to gauge their perceptions and feedback. The SSL product demonstrated energy savings of over 25% while maintaining illuminance levels and improving illuminance uniformity. PNNL's economic analysis yielded a variety of potential payback results depending on the assumptions used. In the best case, replacing HPS with the LED luminaire can yield a payback as low as 3 years. The new lamps were quite popular with the affected personnel, who gave the lighting an average score of 4.46 out of 5 for improvement.« less

  5. Measuring the payback of research activities: a feasible ex-post evaluation methodology in epidemiology and public health.

    PubMed

    Aymerich, Marta; Carrion, Carme; Gallo, Pedro; Garcia, Maria; López-Bermejo, Abel; Quesada, Miquel; Ramos, Rafel

    2012-08-01

    Most ex-post evaluations of research funding programs are based on bibliometric methods and, although this approach has been widely used, it only examines one facet of the project's impact, that is, scientific productivity. More comprehensive models of payback assessment of research activities are designed for large-scale projects with extensive funding. The purpose of this study was to design and implement a methodology for the ex-post evaluation of small-scale projects that would take into account both the fulfillment of projects' stated objectives as well as other wider benefits to society as payback measures. We used a two-phase ex-post approach to appraise impact for 173 small-scale projects funded in 2007 and 2008 by a Spanish network center for research in epidemiology and public health. In the internal phase we used a questionnaire to query the principal investigator (PI) on the outcomes as well as actual and potential impact of each project; in the external phase we sent a second questionnaire to external reviewers with the aim of assessing (by peer-review) the performance of each individual project. Overall, 43% of the projects were rated as having completed their objectives "totally", and 40% "considerably". The research activities funded were reported by PIs as socially beneficial their greatest impact being on research capacity (50% of payback to society) and on knowledge translation (above 11%). The method proposed showed a good discriminating ability that makes it possible to measure, reliably, the extent to which a project's objectives were met as well as the degree to which the project contributed to enhance the group's scientific performance and of its social payback. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Five-city economics of a solar hot-water-system

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report projects energy savings and system costs for five sites using analysis of actual solar energy installation performance in Togus, Maine. Maine system supplies 75 percent of hot water needed for single-family residence; economic payback period is 19 years. Benefits for all sites depend on maintenance or decrease of initial investment required and continuing increase in cost of conventional energy. Report includes analysis weighing potential changes in variables used to evaluate system profitability.

  7. Losses Disguised as Wins Affect Game Selection on Multiline Slots.

    PubMed

    Graydon, Candice; Stange, Madison; Dixon, Mike J

    2018-05-05

    Multiline slots are exciting games that contain features which make them alluring. One such feature is a loss disguised as a win (LDW); wherein, players win less than they wager (e.g., bet 2 dollars, win back 50 cents), but this net loss is disguised by flashing graphics and winning sounds. Research to date concludes that LDWs are both rewarding and reinforcing. Here, we investigated whether LDWs affect players' game selection. Thirty-two undergraduate students with experience playing slot machines played 100 spins on four games-two had positive payback percentages (115%) and two had negative payback percentages (85%) after 100 spins. For each payback percentage condition, there was a game with no LDWs and a game with a moderate number of LDWs. For the 100 spins, players could choose to play whichever game they wished. They then rated their preference for each game following the 100-spins and chose a game to continue playing. The majority of players preferred playing the positive payback percentage game with LDWs and chose to continue playing this game over the three other games. We conclude that in addition to LDWs being reinforcing and rewarding, LDWs do in fact influence game selection. We conclude that responsible gambling initiatives should educate players about LDWs.

  8. Construction costs, payback times, and the leaf economics of carnivorous plants.

    PubMed

    Karagatzides, Jim D; Ellison, Aaron M

    2009-09-01

    Understanding how different plant species and functional types "invest" carbon and nutrients is a major goal of plant ecologists. Two measures of such investments are "construction costs" (carbon needed to produce each gram of tissue) and associated "payback times" for photosynthesis to recover construction costs. These measurements integrate among traits used to assess leaf-trait scaling relationships. Carnivorous plants are model systems for examining mechanisms of leaf-trait coordination, but no studies have measured simultaneously construction costs of carnivorous traps and their photosynthetic rates to determine payback times of traps. We measured mass-based construction costs (CC(mass)) and photosynthesis (A(mass)) for traps, leaves, roots, and rhizomes of 15 carnivorous plant species grown under greenhouse conditions. There were highly significant differences among species in CC(mass) for each structure. Mean CC(mass) of carnivorous traps (1.14 ± 0.24 g glucose/g dry mass) was significantly lower than CC(mass) of leaves of 267 noncarnivorous plant species (1.47 ± 0.17), but all carnivorous plants examined had very low A(mass) and thus, long payback times (495-1551 h). Our results provide the first clear estimates of the marginal benefits of botanical carnivory and place carnivorous plants at the "slow and tough" end of the universal spectrum of leaf traits.

  9. Comparative evaluation of three alternative power cycles for waste heat recovery from the exhaust of adiabatic diesel engines

    NASA Technical Reports Server (NTRS)

    Bailey, M. M.

    1985-01-01

    Three alternative power cycles were compared in application as an exhaust-gas heat-recovery system for use with advanced adiabatic diesel engines. The power cycle alternatives considered were steam Rankine, organic Rankine with RC-1 as the working fluid, and variations of an air Brayton cycle. The comparison was made in terms of fuel economy and economic payback potential for heavy-duty trucks operating in line-haul service. The results indicate that, in terms of engine rated specific fuel consumption, a diesel/alternative-power-cycle engine offers a significant improvement over the turbocompound diesel used as the baseline for comparison. The maximum imporvement resulted from the use of a Rankine cycle heat-recovery system in series with turbocompounding. The air Brayton cycle alternatives studied, which included both simple-cycle and compression-intercooled configurations, were less effective and provided about half the fuel consumption improvement of the Rankine cycle alternatives under the same conditions. Capital and maintenance cost estimates were also developed for each of the heat-recovery power cycle systems. These costs were integrated with the fuel savings to identify the time required for net annual savings to pay back the initial capital investment. The sensitivity of capital payback time to arbitrary increases in fuel price, not accompanied by corresponding hardware cost inflation, was also examined. The results indicate that a fuel price increase is required for the alternative power cycles to pay back capital within an acceptable time period.

  10. Geotheral heating facilities of United Church of Christ (Congregational Church)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-01

    Based on the assumptions made in this study, a geothermal system for the Congregational Church is not economically feasible at this time. A retrofit of the church for geothermal would result in a capital cost of $37,600 including the geothermal well. When this figure is considered in conjunction with the $1892 first-year savings (present fuel cost minus geothermal system O and M cost) and inflation over a 20-year period, a simple payback of 12 years results. In addition, an internal rate of return figure of 8.7 percent was generated. This indicates that the project would have to be financed atmore » less than 9 percent to be economically feasible over a 20-year period.« less

  11. Congeneration feasibility: Otis Elevator Company and Polychrome Corporation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, H.

    1982-05-01

    This report summarizes an investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY. Existing electrical- and steam-producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return-on-investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, thismore » detailed study provides valuable insight into the types of problems encountered when considering cogeneration feasibility.« less

  12. The potential for PVs in Greek commercial buildings

    NASA Astrophysics Data System (ADS)

    Samouil, Chris

    The photovoltaic sector has been growing explosively, worldwide, for the past few years. At present, grid-connected installations dominate the world market. The photovoltaic technology, types of systems, applications and the market of PVs are presented, placing emphasis on installations regarding the building sector. The main focus of the project is concentrated on Greece. The fact that Greece has favourable natural conditions for the exploitation of solar energy, coupled with the support scheme on phototovoltaics introduced with the new law on renewable energy sources voted in June 2006, makes it very interesting to invest in the Greek PV market. Using a newly built office building in Athens with a roof-top PV installation as a case study, this project looks at the viability of grid-connected systems in the building sector. The annual energy output of the system and CO2 emissions reduction were modelled. Embodied energy, installation cost and annual savings were also considered to determine payback periods. The economic payback period of the system was found to be shorter than its lifetime at 16.2 years, reducing to 9.7 years when grants were included. The carbon payback period was calculated at 6.3 years. A sensitivity analysis on the effect of different factors affecting the viability of the PV installation was carried out. Assuming constant electricity rate increases or a more favourable location for the project the results are more attractive. The same case study in Crete would have a payback period reduced by almost 20% compared to that in Athens. A method to extrapolate the findings for the whole building sector of Attica is proposed as a future research project. As an indication it is found that 60,000 similar to the base case roof-top PV systems can produce around 3.1% of the country's thermally produced electricity and save 0.9% of its CO2 emissions. Finally, the strengths and weeknesses of the new RES law are identified and suggestions are made in order to smoothen PV implementation in Greece.

  13. Solar energy system economic evaluation for IBM System 3, Glendo, Wyoming

    NASA Technical Reports Server (NTRS)

    1980-01-01

    This analysis was based on the technical and economic models in f-chart design procedures with inputs based on the characteristics of the parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings, and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables was also investigated.

  14. Functional analysis of the relative growth rate, chemical composition, construction and maintenance costs, and the payback time of Coffea arabica L. leaves in response to light and water availability.

    PubMed

    Cavatte, Paulo C; Rodríguez-López, Nélson F; Martins, Samuel C V; Mattos, Mariela S; Sanglard, Lílian M V P; Damatta, Fábio M

    2012-05-01

    In this study, the combined effects of light and water availability on the functional relationships of the relative growth rate (RGR), leaf chemical composition, construction and maintenance costs, and benefits in terms of payback time for Coffea arabica are presented. Coffee plants were grown for 8 months in 100% or 15% full sunlight and then a four-month water shortage was implemented. Plants grown under full sunlight were also transferred to shade and vice versa. Overall, most of the traits assessed were much more responsive to the availability of light than to the water supply. Larger construction costs (12%), primarily associated with elevated phenol and alkaloid pools, were found under full sunlight. There was a positive correlation between these compounds and the RGR, the mass-based net carbon assimilation rate and the carbon isotope composition ratio, which, in turn, correlated negatively with the specific leaf area. The payback time was remarkably lower in the sun than in shade leaves and increased greatly in water-deprived plants. The differences in maintenance costs among the treatments were narrow, with no significant impact on the RGR, and there was no apparent trade-off in resource allocation between growth and defence. The current irradiance during leaf bud formation affected both the specific leaf area and leaf physiology upon transferring the plants from low to high light and vice versa. In summary, sun-grown plants fixed more carbon for growth and secondary metabolism, with the net effect of an increased RGR.

  15. Post-evaluation of a ground source heat pump system for residential space heating in Shanghai China

    NASA Astrophysics Data System (ADS)

    Lei, Y.; Tan, H. W.; Wang, L. Z.

    2017-11-01

    Residents of Southern China are increasingly concerned about the space heating in winter. The chief aim of the present work is to find a cost-effective way for residential space heating in Shanghai, one of the biggest city in south China. Economic and energy efficiency of three residential space heating ways, including ground source heat pump (GSHP), air source heat pump (ASHP) and wall-hung gas boiler (WHGB), are assessed based on Long-term measured data. The results show that the heat consumption of the building is 120 kWh/m2/y during the heating season, and the seasonal energy efficiency ratio (SEER) of the GSHP, ASHP and WHGB systems are 3.27, 2.30, 0.88 respectively. Compared to ASHP and WHGB, energy savings of GSHP during the heating season are 6.2 kgce/(m2.y) and 2.2 kgce/(m2.y), and the payback period of GSHP are 13.3 and 7.6 years respectively. The sensitivity analysis of various factors that affect the payback period is carried out, and the results suggest that SEER is the most critical factor affecting the feasibility of ground source heat pump application, followed by building load factor and energy price factor. These findings of the research have led the author to the conclusion that ground source heat pump for residential space heating in Shanghai is a good alternative, which can achieve significant energy saving benefits, and a good system design and operation management are key factors that can shorten the payback period.

  16. Guidebook for solar process-heat applications

    NASA Astrophysics Data System (ADS)

    Fazzolare, R.; Mignon, G.; Campoy, L.; Luttmann, F.

    1981-01-01

    The potential for solar process heat in Arizona and some of the general technical aspects of solar, such as insolation, siting, and process analysis are explored. Major aspects of a solar plant design are presented. Collectors, storage, and heat exchange are discussed. Reducing hardware costs to annual dollar benefits is also discussed. Rate of return, cash flow, and payback are discussed as they relate to solar systems. Design analysis procedures are presented. The design cost optimization techniques using a yearly computer simulation of a solar process operation is demonstrated.

  17. Systematic review of methods for evaluating healthcare research economic impact

    PubMed Central

    2010-01-01

    Background The economic benefits of healthcare research require study so that appropriate resources can be allocated to this research, particularly in developing countries. As a first step, we performed a systematic review to identify the methods used to assess the economic impact of healthcare research, and the outcomes. Method An electronic search was conducted in relevant databases using a combination of specific keywords. In addition, 21 relevant Web sites were identified. Results The initial search yielded 8,416 articles. After studying titles, abstracts, and full texts, 18 articles were included in the analysis. Eleven other reports were found on Web sites. We found that the outcomes assessed as healthcare research payback included direct cost-savings, cost reductions in healthcare delivery systems, benefits from commercial advancement, and outcomes associated with improved health status. Two methods were used to study healthcare research payback: macro-economic studies, which examine the relationship between research studies and economic outcome at the aggregated level, and case studies, which examine specific research projects to assess economic impact. Conclusions Our study shows that different methods and outcomes can be used to assess the economic impacts of healthcare research. There is no unique methodological approach for the economic evaluation of such research. In our systematic search we found no research that had evaluated the economic return of research in low and middle income countries. We therefore recommend a consensus on practical guidelines at international level on the basis of more comprehensive methodologies (such as Canadian Academic of Health Science and payback frameworks) in order to build capacity, arrange for necessary informative infrastructures and promote necessary skills for economic evaluation studies. PMID:20196839

  18. Trade-offs between forest carbon stocks and harvests in a steady state - A multi-criteria analysis.

    PubMed

    Pingoud, Kim; Ekholm, Tommi; Sievänen, Risto; Huuskonen, Saija; Hynynen, Jari

    2018-03-15

    This paper provides a perspective for comparing trade-offs between harvested wood flows and forest carbon stocks with different forest management regimes. A constant management regime applied to a forest area with an even age-class distribution leads to a steady state, in which the annual harvest and carbon stocks remain constant over time. As both are desirable - carbon stocks for mitigating climate change and harvests for the economic use of wood and displacing fossil fuels - an ideal strategy should be chosen from a set of management regimes that are Pareto-optimal in the sense of multi-criteria decision-making. When choosing between Pareto-optimal alternatives, the trade-off between carbon stock and harvests is unavoidable. This trade-off can be described e.g. in terms of carbon payback times or carbon returns. As numerical examples, we present steady-state harvest levels and carbon stocks in a Finnish boreal forest region for different rotation periods, thinning intensities and collection patterns for harvest residues. In the set of simulated management practices, harvest residue collection presents the most favorable trade-off with payback times around 30-40 years; while Pareto-optimal changes in rotation or thinnings exhibited payback times over 100 years, or alternatively carbon returns below 1%. By extending the rotation period and using less-intensive thinnings compared to current practices, the steady-state carbon stocks could be increased by half while maintaining current harvest levels. Additional cases with longer rotation periods should be also considered, but were here excluded due to the lack of reliable data on older forest stands. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Techno-economic feasibility of waste biorefinery: Using slaughtering waste streams as starting material for biopolyester production.

    PubMed

    Shahzad, Khurram; Narodoslawsky, Michael; Sagir, Muhammad; Ali, Nadeem; Ali, Shahid; Rashid, Muhammad Imtiaz; Ismail, Iqbal Mohammad Ibrahim; Koller, Martin

    2017-09-01

    The utilization of industrial waste streams as input materials for bio-mediated production processes constitutes a current R&D objective not only to reduce process costs at the input side but in parallel, to minimize hazardous environmental emissions. In this context, the EU-funded project ANIMPOL elaborated a process for the production of polyhydroxyalkanoate (PHA) biopolymers starting from diverse waste streams of the animal processing industry. This article provides a detailed economic analysis of PHA production from this waste biorefinery concept, encompassing the utilization of low-quality biodiesel, offal material and meat and bone meal (MBM). Techno-economic analysis reveals that PHA production cost varies from 1.41 €/kg to 1.64 €/kg when considering offal on the one hand as waste, or, on the other hand, accounting its market price, while calculating with fixed costs for the co-products biodiesel (0.97 €/L) and MBM (350 €/t), respectively. The effect of fluctuating market prices for offal materials, biodiesel, and MBM on the final PHA production cost as well as the investment payback time have been evaluated. Depending on the current market situation, the calculated investment payback time varies from 3.25 to 4.5years. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Evaluation of auxiliary power subsystems for gas engine heat pumps, phase 2

    NASA Astrophysics Data System (ADS)

    Rasmussen, R. W.; Wahlstedt, D. A.; Planer, N.; Fink, J.; Persson, E.

    1988-12-01

    The need to determine the practical, technical and economic viability for a stand-alone Gas Engine Heat Pump (GEHP) system capable of generating its own needed electricity is addressed. Thirty-eight reasonable design configurations were conceived based upon small-sized power conversion equipment that is either commercially available or close to emerging on the market. Nine of these configurations were analyzed due to their potential for low first cost, high conversion efficiency, availability or simplicity. It was found that electric consumption can be reduced by over 60 percent through the implementation of high efficiency, brushless, permanent magnet motors as fan and pump drivers. Of the nine selected configurations employing variable-speed fans, two were found to have simple incremental payback periods of 4.2 to 16 years, depending on the U.S. city chosen for analysis. Although the auxiliary power subsystem option is only marginally attractive from an economic standpoint, the increased gas load provided to the local gas utility may be sufficient to encourage further development. The ability of the system to operate completely disconnected from the electric power source may be a feature of high merit.

  1. Need for Systematic Retrofit Analysis in Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malhotra, Mini; Im, Piljae

    2014-01-01

    Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets ofmore » measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.« less

  2. Net energy payback and CO2 emissions from three midwestern wind farms: An update

    USGS Publications Warehouse

    White, S.W.

    2006-01-01

    This paper updates a life-cycle net energy analysis and carbon dioxide emissions analysis of three Midwestern utility-scale wind systems. Both the Energy Payback Ratio (EPR) and CO2 analysis results provide useful data for policy discussions regarding an efficient and low-carbon energy mix. The EPR is the amount of electrical energy produced for the lifetime of the power plant divided by the total amount of energy required to procure and transport the materials, build, operate, and decommission the power plants. The CO2 analysis for each power plant was calculated from the life-cycle energy input data. A previous study also analyzed coal and nuclear fission power plants. At the time of that study, two of the three wind systems had less than a full year of generation data to project the life-cycle energy production. This study updates the analysis of three wind systems with an additional four to eight years of operating data. The EPR for the utility-scale wind systems ranges from a low of 11 for a two-turbine system in Wisconsin to 28 for a 143-turbine system in southwestern Minnesota. The EPR is 11 for coal, 25 for fission with gas centrifuge enriched uranium and 7 for gaseous diffusion enriched uranium. The normalized CO2 emissions, in tonnes of CO2 per GW eh, ranges from 14 to 33 for the wind systems, 974 for coal, and 10 and 34 for nuclear fission using gas centrifuge and gaseous diffusion enriched uranium, respectively. ?? Springer Science+Business Media, LLC 2007.

  3. Analysis of the economics of typical business applications of solar energy

    NASA Astrophysics Data System (ADS)

    1981-11-01

    An economic analysis is provided of flat plate collector systems in industrial, commercial, and agricultural business applications in a variety of locations. A key element of the analysis is the federal solar investment tax credit. The SOLCOST Solar Energy Design Program is used for the study. The differences between industrial agricultural and commercial applications are considered, as are finance and tax data and fuel data. The rate of return and payback are the criteria used to compare the economic viability of systems. Market penetration estimates for process steam were derived for seven southwestern states where direct solar radiation is highest.

  4. Stockbridge Munsee Community Health and Wellness Center and the Mohican Family Center Renewable Energy and Energy Efficiency Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRocher, Andy; Barrnett, Michael

    2014-03-14

    The results of the Renewable Energy and Energy Efficiency Feasibility Study of Stockbridge Munsee Community’s Health and Wellness Center (HWC) indicate that a variety of renewable energy options and energy conservation measures (ECMs) exist for the facility. A requirement of the Request for Proposal for this study was to assess renewable energy options that could offset 30 to 100 percent of the HWC’s energy use. This study identifies that a geothermal system is the most cost effective renewable energy option available to decrease the HWC’s energy consumption by 30 to 100 percent. Currently the HWC performs in the lowest 8more » percent of buildings in its building category, as scored in the EPA portfolio manager benchmarking tool. Multiple ECM opportunities have been identified with paybacks of less than five years to yield an estimated 25-percent decrease in annual energyconsumption. The ECMs within this payback period are estimated to save $26,800 per year with an implementation cost of just $4,650 (0.2 year payback). For the Mohican Family Center document: The results of the Renewable Energy and Energy Efficiency Feasibility Study of Stockbridge Munsee Community’s Mohican Family Center (MFC) indicate that a variety of renewable energy options and energy conservation measures (ECMs) exist for the facility. A requirement of the Request for Proposal for this study was to assess renewable energy options that could offset 30 to 100 percent of the MFC’s energy use. This study identifies that a geothermal system is the most cost effective renewable energy option available to decrease the MFC’s energy consumption by 30 to 100 percent. Currently the MFC performs better than 80 percent of buildings in its building category, as scored in the EPA portfolio manager benchmarking tool. Multiple ECM opportunities have been identified with short term paybacks to yield an estimated 13-percent decrease in energy consumption. The ECMs within this payback period are estimated to save $3,100 per year with an implementation cost of under $20,000.« less

  5. Simplified energy design economics: Principles of economics applied to energy conservation and solar energy investments in buildings

    NASA Astrophysics Data System (ADS)

    Marshall, H. E.; Ruegg, R. T.; Wilson, F.

    1980-01-01

    Economic analysis techniques for evaluating alternative energy conservation investments in buildings are presented. Life cycle cost, benefit cost, savings to investment, payback, and rate of return analyses are explained and illustrated. The procedure for discounting is described for a heat pump investment. Formulas, tables of discount factors, and detailed instructions are provided to give all information required to make economic evaluations of energy conserving building designs.

  6. Building-integrated photovoltaics: A case study

    NASA Astrophysics Data System (ADS)

    Kiss, G.; Kinkead, J.; Raman, M.

    1995-03-01

    In 1992, Kiss Cathcart Anders Architects performed a study for NREL on Building-Integrated Photovoltaics (BIPV) issues as seen from the perspective of the building community. In general, the purpose of the study was to list major issues and potential applications; by it's nature it asked more questions than it answered. This second phase study was to produce quantitative data on the performance of specific BIPV systems. Only roof systems are evaluated. The energy performance, construction cost and simple payback for five different BIPV roof options are evaluated in six different locations: Oakland, New York, Miami, Phoenix, Chicago, and Cincinnati. The roof options evaluated include the following: single-glazed PV roof using glass-substrate PVs; double-glazed PV roof with insulating PV modules; ballasted roof-mounted system; sawtooth light monitor roof with indirect north daylighting; sawtooth roof with north light and active heat recovery.

  7. Energy analysis of cool, medium, and dark roofs on residential buildings in the U.S

    NASA Astrophysics Data System (ADS)

    Dunbar, Michael A.

    This study reports an energy analysis of cool, medium, and dark roofs on residential buildings in the U.S. Three analyses were undertaken in this study: energy consumption, economic analysis, and an environmental analysis. The energy consumption reports the electricity and natural gas consumption of the simulations. The economic analysis uses tools such as simple payback period (SPP) and net present value (NPV) to determine the profitability of the cool roof and the medium roof. The variable change for each simulation model was the roof color. The default color was a dark roof and the results were focused on the changes produced by the cool roof and the medium roof. The environmental analysis uses CO2 emissions to assess the environmental impact of the cool roof and the medium roof. The analysis uses the U.S. Department of Energy (DOE) EnergyPlus software to produce simulations of a typical, two-story residential home in the U.S. The building details of the typical, two-story U.S. residential home and the International Energy Conservation Code (IECC) building code standards used are discussed in this study. This study indicates that, when material and labor costs are. assessed, the cool roof and the medium roof do not yield a SPP less than 10 years. Furthermore, the NPV results assess that neither the cool roof nor the medium roof are a profitable investment in any climate zone in the U.S. The environmental analysis demonstrates that both the cool roof and the medium roof have a positive impact in warmer climates by reducing the CO2 emissions as much as 264 kg and 129 kg, respectively.

  8. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a conventional system. The payback periods observed support the concept of introducing the FREEDM system.

  9. Energy management system saves $250,000 + fuel -with 4-mo payback

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massey, C.L.; Robe, K.

    1980-09-01

    Innovations made at Hershey Chocolate Company's Oakdale, California plant eliminated simultaneous cool-reheat-cycles by incorporating dead band controls into existing HVAC systems. Calculated savings of the project are about 90% of former heating and cooling energy usage for HVAC operation. Electric power savings amount to about $75,000/y, and natural gas savings about $185,000/y, using 1980 fuel costs, with an approximate 4-month payback. Because of the reduced demand for chilled water, a smaller water chiller carries full plant load for 4 to 5 months of the year without operating two existing 500-ton units.

  10. Architecturally sensitive retrofitting of PV to a residential block in Greece to reduce its carbon footprint

    NASA Astrophysics Data System (ADS)

    Panopoulou, Ismini

    Photovoltaic power is a unique energy source, with wide distribution potential, which can be integrated within the fabric of individual buildings, transforming the power generation in a less large-scale and regionally located issue. As a result, photovoltaic power is a free, clean and silent electrical supply that can be introduced into cities and residential areas. Over the past years, grid-connected, distributed photovoltaic power systems have become an explosively growing sector worldwide. This trend is expected to be continued in the future and solar systems may become a common building element of building construction. In Greece, where the main focus of the project is concentrated, the extended sunshine and the incentives of the new Renewable Energy Sources law of 2006, give a different perspective in photovoltaic investments. In the case study of Vera Water Residence complex in Athens, the viability of an architecturally sensitive retrofitting of PV was examined, from both financial and environmental aspects. The project was concentrated in one of the complex's buildings which was modelled in TAS simulator in order for the annual heating and cooling loads to be estimated. A closer to the reality estimation of electricity demand was made through the annual electricity bills of the building. The proposed building integrated photovoltaic system was designed in terms of following and respecting the aesthetics of the existing architecture of the complex while being as efficient as possible. The annual energy output and C02 emissions reductions were then calculated through RETScreen software analysis according to the location of the project and the characteristics of the PV system. Finally, an economic analysis has been included to the study, considering the installation cost, the annual savings and the embodied energy of the system, in order for the payback period of the investment to be determined. Finally, a small sensitivity analysis concerning the effect of different factors influencing the feasibility of the PV investment was carried out and as it was expected it had significant effect on the initially calculated the payback period value. The expected future increase of fuel prices and the reduction of the investment's initial cost due to government grants, added to the prospect of new future tax incentive and subsidies, have made the prospect of the project more attractive while significantly reducing the payback period.

  11. Wastewater recycling and heat reclamation at the Red Lion Central Laundry, Portland, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlick, T.F.; Halverson, M.A.; Ledbetter, M.R.

    1996-09-01

    This report discusses water, energy, and cost savings that can be achieved in a commercial laundry through the use of a wastewater recycling and heat recovery system. Cost savings are achieved through reductions in water use, reduction in sewage charges, reductions in water heating energy, and potential reductions in water treatment chemicals. This report provides an economic analysis of the impact of capital investment, daily consumption, and local utility rates on the payback period.

  12. Manned Orbital Transfer Vehicle (MOTV). Volume 5: Turnaround analysis

    NASA Technical Reports Server (NTRS)

    Boyland, R. E.; Sherman, S. W.; Morfin, H. W.

    1979-01-01

    The development of a low-cost reliable turnaround process to employ the MOTV in enhancing the utilization of the geosynchronous space region is analyzed. It is indicated that a routine effective turnaround/maintenance plan must make maximum use of flight data for maintenance planning, a high degree of test automation, and MOTV maintainability features in order to minimize tests, facilitate repair, and reduce manpower requirements. An effective turnaround plan provides a payback of reduced risks.

  13. Economic analysis of solar assisted absorption chiller for a commercial building

    NASA Astrophysics Data System (ADS)

    Antonyraj, Gnananesan

    Dwindling fossil fuels coupled with changes in global climate intensified the drive to make use of renewable energy resources that have negligible impact on the environment. In this attempt, the industrial community produced various devices and systems to make use of solar energy for heating and cooling of building space as well as generate electric power. The most common components employed for collection of solar energy are the flat plate and evacuated tube collectors that produce hot water that can be employed for heating the building space. In order to cool the building, the absorption chiller is commonly employed that requires hot water at high temperatures for its operation. This thesis deals with economic analysis of solar collector and absorption cooling system to meet the building loads of a commercial building located in Chattanooga, Tennessee. Computer simulations are employed to predict the hourly building loads and performance of the flat plate and evacuated tube solar collectors using the hourly weather data. The key variables affecting the economic evaluation of such system are identified and the influence of these parameters is presented. The results of this investigation show that the flat plate solar collectors yield lower payback period compared to the evacuated tube collectors and economic incentives offered by the local and federal agencies play a major role in lowering the payback period.

  14. Leadership, institution building and pay-back of health systems research in Mexico

    PubMed Central

    González-Block, Miguel Angel

    2009-01-01

    Background Health systems research is being increasingly called upon to support scaling up of disease control interventions and to support rapid health sector change. Yet research capacity building and pay-back take years or even decades to be demonstrated, while leadership and institution building are critical for their success. The case of Mexico can be illustrative for middle income countries and emerging economies striving to build health research systems. Methods Historical reflection suggests the relationship between health sector reforms and economic crisis, on the one hand, and research capacity building and payback, on the other. Mexico's post-revolutionary background and its three health sector reforms are analyzed to identify the emphases given to health systems research. Results The first wave of health reform in the 1940s emphasized clinical and epidemiological research. Health systems research was not encouraged in a context of rapid economic development and an authoritarian regime. In contrast, health systems research was given a privileged place with the second wave of health reforms in the 1980s, which addressed health system coordination, decentralization and the universal right to health in a context of a deep economic crisis. The third wave of health reforms between 2003 and 2006 was based on the health system models proposed through research in the 90s. The credibility gained by research institutions was critical to ensure government uptake. Research influence can be traced through the role it played in defining a problem, in designing innovative insurance mechanisms and in establishing evaluation frameworks. It is argued that the Ministry of Health's budget increase of 56% between 2003 and 2006 and the reductions in inequity are pay-back to research investments since the 1980s. PMID:19793399

  15. Guide to the economic analysis of community energy systems

    NASA Astrophysics Data System (ADS)

    Pferdehirt, W. P.; Croke, K. G.; Hurter, A. P.; Kennedy, A. S.; Lee, C.

    1981-08-01

    This guidebook provides a framework for the economic analysis of community energy systems. The analysis facilitates a comparison of competing configurations in community energy systems, as well as a comparison with conventional energy systems. Various components of costs and revenues to be considered are discussed in detail. Computational procedures and accompanying worksheets are provided for calculating the net present value, straight and discounted payback periods, the rate of return, and the savings to investment ratio for the proposed energy system alternatives. These computations are based on a projection of the system's costs and revenues over its economic lifetimes. The guidebook also discusses the sensitivity of the results of this economic analysis to changes in various parameters and assumptions.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radhi, Hassan

    Developments in the design and manufacture of photovoltaic cells have recently been a growing concern in the UAE. At present, the embodied energy pay-back time (EPBT) is the criterion used for comparing the viability of such technology against other forms. However, the impact of PV technology on the thermal performance of buildings is not considered at the time of EPBT estimation. If additional energy savings gained over the PV system life are also included, the total EPBT could be shorter. This paper explores the variation of the total energy of building integrated photovoltaic systems (BiPV) as a wall cladding systemmore » applied to the UAE commercial sector and shows that the ratio between PV output and saving in energy due to PV panels is within the range of 1:3-1:4. The result indicates that for the southern and western facades in the UAE, the embodied energy pay-back time for photovoltaic system is within the range of 12-13 years. When reductions in operational energy are considered, the pay-back time is reduced to 3.0-3.2 years. This study comes to the conclusion that the reduction in operational energy due to PV panels represents an important factor in the estimation of EPBT. (author)« less

  17. Survey Evidence on the Willingness of U.S. Consumers to Pay for Automotive Fuel Economy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greene, David L; Evans, David H; Hiestand, John

    2013-01-01

    Prospect theory, which was awarded the Nobel Prize in Economics in 2002, holds that human beings faced with a risky bet will tend to value potential losses about twice as much as potential gains. Previous research has demonstrated that prospect theory could be sufficient to explain an energy paradox in the market for automotive fuel economy. This paper analyzes data from four random sample surveys of 1,000 U.S. households each in 2004, 2011, 2012 and 2013. Households were asked about willingness to pay for future fuel savings as well as the annual fuel savings necessary to justify a given upfrontmore » payment. Payback periods inferred from household responses are consistent over time and across different formulations of questions. Mean calculated payback periods are short, about 3 years, but there is substantial dispersion among individual responses. Calculated payback periods do not appear to be correlated with the attributes of respondents. Respondents were able to quantitatively describe their uncertainty about both vehicle fuel economy and future fuel prices. Simulation of loss averse behavior based on this stated uncertainty illustrate how loss aversion could lead consumers to substantially undervalue future fuel savings relative to their expected value.« less

  18. Domestic refrigeration appliances in Poland: Potential for improving energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyers, S.; Schipper, L.; Lebot, B.

    1993-08-01

    This report is based on information collected from the main Polish manufacturer of refrigeration appliances. We describe their production facilities, and show that the energy consumption of their models for domestic sale is substantially higher than the average for similar models made in W. Europe. Lack of data and uncertainty about future production costs in Poland limits our evaluation of the cost-effective potential to increase energy efficiency, but it appears likely that considerable improvement would be economic from a societal perspective. Many design options are likely to have a simple payback of less than five years. We found that themore » production facilities are in need of substantial modernization in order to produce higher quality and more efficient appliances. We discuss policy options that could help to build a market for more efficient appliances in Poland and thereby encourage investment to produce such equipment.« less

  19. Building-integrated photovoltaics: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiss, G.; Kinkead, J.; Raman, M.

    1995-03-01

    In 1992, Kiss Cathcart Anders Architects performed a study for NREL on Building-Integrated Photovoltaics (BIPV) issues as seen from the perspective of the building community. In general, the purpose of the study was to list major issues and potential applications; by it`s nature it asked more questions than it answered. This second phase study was to produce quantitative data on the performance of specific BIPV systems. Only roof systems are evaluated. The energy performance, construction cost and simple payback for five different BIPV roof options are evaluated in six different locations: Oakland, New York, Miami, Phoenix, Chicago, and Cincinnati. Themore » roof options evaluated include the following: single-glazed PV roof using glass-substrate PVs; double-glazed PV roof with insulating PV modules; ballasted roof-mounted system; sawtooth light monitor roof with indirect north daylighting; sawtooth roof with north light and active heat recovery.« less

  20. Impact of Different Economic Performance Metrics on the Perceived Value of Solar Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drury, E.; Denholm, P.; Margolis, R.

    2011-10-01

    Photovoltaic (PV) systems are installed by several types of market participants, ranging from residential customers to large-scale project developers and utilities. Each type of market participant frequently uses a different economic performance metric to characterize PV value because they are looking for different types of returns from a PV investment. This report finds that different economic performance metrics frequently show different price thresholds for when a PV investment becomes profitable or attractive. Several project parameters, such as financing terms, can have a significant impact on some metrics [e.g., internal rate of return (IRR), net present value (NPV), and benefit-to-cost (B/C)more » ratio] while having a minimal impact on other metrics (e.g., simple payback time). As such, the choice of economic performance metric by different customer types can significantly shape each customer's perception of PV investment value and ultimately their adoption decision.« less

  1. Utilization of geothermal energy-feasibility study, Ojo Caliente Mineral Springs Company, Ojo Caliente, New Mexico

    NASA Astrophysics Data System (ADS)

    1982-04-01

    The feasibility of a geothermal heating system at the Ojo Caliente Mineral Springs Co. was investigated. The geothermal energy will be used to preheat hot water for the laundry facilities and to heat the water for a two pipe fan coil heating system in the hotel. Present annual heating fuel costs of $11,218 for propane will be replaced by electricity to operate fans and pump at an annual cost of $2547, resulting in a net savings of $8671. Installation costs include $10,100 for a well system, $1400 for a laundry system, and $41,100 for a heating system. With the addition of a 10% design fee the total installation cost is $57,860. Ignoring escalating propane fuel prices, tax credits for energy conservation equipment, and potential funding from the State of New Mexico for a geothermal demonstration project, the simple economic payback period for this project is 6.7 years.

  2. Outcome-Driven Service Provider Performance under Conditions of Complexity and Uncertainty, Defense Acquisition in Transition, Volume 2, 13-14 May 2009.

    DTIC Science & Technology

    2009-04-22

    bandwidth and response times. Forrester Research uses the analogy of a consumer using an automated teller machine to explain how technical SLAs should...be crafted. “It’s not enough that you put your card and Personal Identification Number (PIN) [in the machine ] and request to withdraw cash...IRR) Net Present Value (NPV) Other Relevant Metrics Payback Period Cost/Benefit Ratio Cost, Economic, and/or Financial Analysis Yes Yes Yes

  3. Regional hospital improves efficiency with co-generation retrofit.

    PubMed

    Knutson, D; Anderson, L

    1999-11-01

    Feasibility analysis of the co-generation retrofit of the Red Deer Regional Hospital pointed to a reasonable payback of capital cost and increased efficiency in operation of the facility. Budget restrictions nearly stopped the project from proceeding. Innovative construction procedures proposed by the Facility Management Group, in particular, Mr Keith Metcalfe, Director of Maintenance, allowed a worthwhile project to reach successful completion. We feel that this model can perhaps be used by similar facilities in the future to achieve their energy efficiency goals.

  4. Associated petroleum gas utilization in Tomsk Oblast: energy efficiency and tax advantages

    NASA Astrophysics Data System (ADS)

    Vazim, A.; Romanyuk, V.; Ahmadeev, K.; Matveenko, I.

    2015-11-01

    This article deals with oil production companies activities in increasing the utilization volume of associated petroleum gas (APG) in Tomsk Oblast. Cost-effectiveness analysis of associated petroleum gas utilization was carried out using the example of gas engine power station AGP-350 implementation at Yuzhno-Cheremshanskoye field, Tomsk Oblast. Authors calculated the effectiveness taking into account the tax advantages of 2012. The implementation of this facility shows high profitability, the payback period being less than 2 years.

  5. Solar energy system economic evaluation: IBM System 4, Clinton, Mississippi

    NASA Technical Reports Server (NTRS)

    1980-01-01

    An economic analysis of the solar energy system was developed for five sites, typical of a wide range of environmental and economic conditions in the continental United States. The analysis was based on the technical and economic models in the F-chart design procedure, with inputs based on the characteristic of the installed system and local conditions. The results are of the economic parameters of present worth of system cost over a 20 year time span: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  6. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Conlin, Francis; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  7. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  8. U.S. Energy Service Company Industry: Market Size and Project Performance from 1990-2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Peter; Goldman, Charles; Satchwell, Andrew

    2012-08-21

    The U.S. energy service company (ESCO) industry is an example of a private sector business model where energy savings are delivered to customers primarily through the use of performance-based contracts. This study was conceived as a snapshot of the ESCO industry prior to the economic slowdown and the introduction of federal stimulus funding mandated by enactment of the American Recovery and Reinvestment Act of 2009 (ARRA). This study utilizes two parallel analytic approaches to characterize ESCO industry and market trends in the U.S.: (1) a ?top-down? approach involving a survey of individual ESCOs to estimate aggregate industry activity and (2)more » a ?bottom-up? analysis of a database of ~;;3,250 projects (representing over $8B in project investment) that reports market trends including installed EE retrofit strategies, project installation costs and savings, project payback times, and benefit-cost ratios over time. Despite the onset of a severe economic recession, the U.S. ESCO industry managed to grow at about 7percent per year between 2006 and 2008. ESCO industry revenues were about $4.1 billion in 2008 and ESCOs anticipate accelerated growth through 2011 (25percent per year). We found that 2,484 ESCO projects in our database generated ~;;$4.0 billion ($2009) in net, direct economic benefits to their customers. We estimate that the ESCO project database includes about 20percent of all U.S. ESCO market activity from 1990-2008. Assuming the net benefits per project are comparable for ESCO projects that are not included in the LBNL database, this would suggest that the ESCO industry has generated ~;;$23 billion in net direct economic benefits for customers at projects installed between 1990 and 2008. There is empirical evidence confirming that the industry is evolving by installing more comprehensive and complex measures?including onsite generation and measures to address deferred maintenance?but this evolution has significant implications for customer project economics, especially at K-12 schools. We found that the median simple payback time has increased from 1.9 to 3.2 years in private sector projects since the early-to-mid 1990s and from 5.2 to 10.5 years in public sector projects for the same time period.« less

  9. Oil Bypass Filter Technology Evaluation - Third Quarterly Report, April--June 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurence R. Zirker; James E. Francfort

    2003-08-01

    This Third Quarterly report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy’s FreedomCAR & Vehicle Technologies Program. Eight full-size, four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass filter systems from the PuraDYN Corporation. The reported engine lubricating oil-filtering capability (down to 0.1 microns) and additive package of the bypass filter system is intended to extend oil-drain intervals. To validate the extended oil-drain intervals, an oil-analysis regime monitors the presence of necessary additives inmore » the oil, detects undesirable contaminants and engine wear metals, and evaluates the fitness of the oil for continued service. The eight buses have accumulated 185,000 miles to date without any oil changes. The preliminary economic analysis suggests that the per bus payback point for the oil bypass filter technology should be between 108,000 miles when 74 gallons of oil use is avoided and 168,000 miles when 118 gallons of oil use is avoided. As discussed in the report, the variation in the payback point is dependant on the assumed cost of oil. In anticipation of also evaluating oil bypass systems on six Chevrolet Tahoe sport utility vehicles, the oil is being sampled on the six Tahoes to develop an oil characterization history for each engine.« less

  10. An assessment of the impact of the NHS Health Technology Assessment Programme.

    PubMed

    Hanney, S; Buxton, M; Green, C; Coulson, D; Raftery, J

    2007-12-01

    To consider how the impact of the NHS Health Technology Assessment (HTA) Programme should be measured. To determine what models are available and their strengths and weaknesses. To assess the impact of the first 10 years of the NHS HTA programme from its inception in 1993 to June 2003 and to identify the factors associated with HTA research that are making an impact. Main electronic databases from 1990 to June 2005. The documentation of the National Coordinating Centre for Health Technology Assessment (NCCHTA). Questionnaires to eligible researchers. Interviews with lead investigators. Case study documentation. A literature review of research programmes was carried out, the work of the NCCHTA was reviewed, lead researchers were surveyed and 16 detailed case studies were undertaken. Each case study was written up using the payback framework. A cross-case analysis informed the analysis of factors associated with achieving payback. Each case study was scored for impact before and after the interview to assess the gain in information due to the interview. The draft write-up of each study was checked with each respondent for accuracy and changed if necessary. The literature review identified a highly diverse literature but confirmed that the 'payback' framework pioneered by Buxton and Hanney was the most widely used and most appropriate model available. The review also confirmed that impact on knowledge generation was more easily quantified than that on policy, behaviour or especially health gain. The review of the included studies indicated a higher level of impact on policy than is often assumed to occur. The survey showed that data pertinent to payback exist and can be collected. The completed questionnaires showed that the HTA Programme had considerable impact in terms of publications, dissemination, policy and behaviour. It also showed, as expected, that different parts of the Programme had different impacts. The Technology Assessment Reports (TARs) for the National Institute for Health and Clinical Excellence (NICE) had the clearest impact on policy in the form of NICE guidance. Mean publications per project were 2.93 (1.98 excluding the monographs), above the level reported for other programmes. The case studies revealed the large diversity in the levels and forms of impacts and the ways in which they arise. All the NICE TARs and more than half of the other case studies had some impact on policy making at the national level whether through NICE, the National Screening Committee, the National Service Frameworks, professional bodies or the Department of Health. This underlines the importance of having a customer or 'receptor' body. A few case studies had very considerable impact in terms of knowledge production and in informing national and international policies. In some of these the principal investigator had prior expertise and/or a research record in the topic. The case studies confirmed the questionnaire responses but also showed how some projects led to further research. This study concluded that the HTA Programme has had considerable impact in terms of knowledge generation and perceived impact on policy and to some extent on practice. This high impact may have resulted partly from the HTA Programme's objectives, in that topics tend to be of relevance to the NHS and have policy customers. The required use of scientific methods, notably systematic reviews and trials, coupled with strict peer reviewing, may have helped projects publish in high-quality peer-reviewed journals. Further research should cover more detailed, comprehensive case studies, as well as enhancement of the 'payback framework'. A project that collated health research impact studies in an ongoing manner and analysed them in a consistent fashion would also be valuable.

  11. Semiconductor grade, solar silicon purification project

    NASA Technical Reports Server (NTRS)

    Ingle, W. M.; Rosler, R. R.; Thompson, S. W.; Chaney, R. E.

    1979-01-01

    Experimental apparatus and procedures used in the development of a 3-step SiF2(x) polymer transport purification process are described. Both S.S.M.S. and E.S. analysis demonstrated that major purification had occured and some samples were indistinguishable from semiconductor grade silicon (except possibly for phosphorus). Recent electrical analysis via crystal growth reveals that the product contains compensated phosphorus and boron. The low projected product cost and short energy payback time suggest that the economics of this process will result in a cost less than the goal of $10/Kg(1975 dollars). The process appears to be readily scalable to a major silicon purification facility.

  12. A Demonstration System for Capturing Geothermal Energy from Mine Waters beneath Butte, Montana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackketter, Donald

    2015-06-01

    Executive Summary An innovative 50-ton ground-source heat pump (GSHP) system was installed to provide space heating and cooling for a 56,000 square foot (5,200 square meter) building in Butte Montana, in conjunction with its heating and chiller systems. Butte is a location with winter conditions much colder than the national average. The GSHP uses flooded mine waters at 78F (25C) as the heat source and heat sink. The heat transfer performance and efficiency of the system were analyzed using data from January through July 2014. This analysis indicated that for typical winter conditions in Butte, Montana, the GSHP could delivermore » about 88% of the building’s annual heating needs. Compared with a baseline natural-gas/electric system, the system demonstrated at least 69% site energy savings, 38% source energy savings, 39% carbon dioxide emissions reduction, and a savings of $17,000 per year (40%) in utility costs. Assuming a $10,000 per ton cost for installing a production system, the payback period at natural gas costs of $9.63/MMBtu and electricity costs of $0.08/kWh would be in the range of 40 to 50 years. At higher utility prices, or lower installation costs, the payback period would obviously be reduced.« less

  13. When perfectly HLA-matched kidneys are refused for transplant: implications for a national cooperative sharing system.

    PubMed

    Ellison, M D; Breen, T J; Davies, D B; Edwards, E B; Mahoney, R J; Daily, O P; Norman, D J

    1996-11-01

    The transplant community attempts to maximize overall renal graft survival rates through nationwide sharing of perfectly-matched cadaveric kidneys. Although the number of such transplants is determined annually, the number available but not transplanted has never been assessed. There has also been no verification of the widespread claim that kidneys transplanted as paybacks for perfect matches are inferior. From records of the United Network for Organ Sharing, a complete accounting of six-antigen-matched kidney disposition was obtained, including a frequency distribution of reasons for refusal given when kidneys were refused for matched patients. Actuarial graft survival (GS) rates for matched, payback, and other cadaveric renal transplants were determined. Of the six-antigen-matched kidneys available, 97 percent were transplanted; 71 percent of those were accepted for matched patients. The two-year GS rate for matched patients was 84 percent, significantly higher than that for kidneys available for matched patients but transplanted into other patients (71.3 percent) and that for all other cadaveric kidneys (75.5 percent). Most reasons for refusal were related to donor quality. Kidneys refused for such reasons showed a 67.7 percent two-year GS rate in nonmatched patients and the highest rates of acute and chronic rejection and primary failure. The two-year GS rate for kidneys accepted as paybacks for matched kidneys (75.7 percent) was equivalent to that for all non-matched cadaveric kidneys (75.5 percent). If all normal-quality grafts refused for perfectly matched patients during 1990 through 1992 had been accepted for those patients, the number of transplants with typically superior survival rates could have increased by 25 percent, from 1,365 to 1,704. The payback requirement of the United Network for Organ Sharing does not seem to reduce the overall benefits of sharing perfectly matched kidneys nationwide.

  14. Energy savings and cost-benefit analysis of the new commercial building standard in China

    DOE PAGES

    Zhao, Shanguo; Feng, Wei; Zhang, Shicong; ...

    2015-10-07

    In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less

  15. Energy savings and cost-benefit analysis of the new commercial building standard in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Shanguo; Feng, Wei; Zhang, Shicong

    In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less

  16. Vacuum boilers developed heating surfaces technic and economic efficiency evaluation

    NASA Astrophysics Data System (ADS)

    Slobodina, E. N.; Mikhailov, A. G.; Semenov, B. A.

    2018-01-01

    The vacuum boilers as manufacturing proto types application analysis was carried out, the possible directions for the heating surfaces development are identified with a view to improving the energy efficiency. Economic characteristics to evaluate the vacuum boilers application efficiency (Net Discounted Income (NDI), Internal Rate of Return (IRR), Profitability Index (PI) and Payback Period) are represented. The given type boilers application technic and economic efficiency criteria were established. NDI changing curves depending on the finning coefficient and operating pressure were obtained as a result of the conducted calculation studies.

  17. Direct application of geothermal energy at the L'eggs Product Plant, Las Cruces, New Mexico. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-02-01

    The study program to determine the feasibility of interfacing a potential geothermal resource of Dona Ana County, New Mexico L'eggs Product industrial process is discussed in this final report. Five separate sites were evaluated initially as to geothermal potential and technical feasibility. Preliminary analysis revealed that three sites were considered normal, but that two sites (about three miles from the L'eggs Plant) had very high shallow subsurface temperature gradients (up to 14.85/sup 0/F/100 ft). An initial engineering analysis showed that to meet the L'eggs plant temperature and energy requirements a geothermal fluid temperature of about 250/sup 0/F and 200 gpmmore » flow rate would be necessary. A brief economic comparison indicated that the L'eggs plant site and a geothermal site approximately four miles from the plant did merit further investigation. Detailed engineering and economic design and analysis of these two sites (including the drilling of an 1873 feet deep temperature gradient test hole at the L'eggs Plant) showed that development of the four mile distant site was technically feasible and was the more economic option. It was determined that a single-stage flash system interface design would be most appropriate for the L'eggs Plant. Approximately 39 billion Btu/yr of fossil fuel could be replaced with geothermal energy at the L'eggs facility for a total installed system cost of slightly over $2 million. The projected economic payback period was calculated to be 9.2 years before taxes. This payback was not considered acceptable by L'eggs Products, Inc., to merit additional design or construction work at this time.« less

  18. Public Housing: A Tailored Approach to Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Podorson, D.

    2014-06-01

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at themore » time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less

  19. PAYBACK Act

    THOMAS, 111th Congress

    Rep. Space, Zachary T. [D-OH-18

    2009-11-04

    House - 12/04/2009 Referred to the Subcommittee on Border, Maritime, and Global Counterterrorism. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  20. Cost effectiveness of converting to alternative motor vehicle fuels. A technical assistance study for the City of Longview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCoy, G.A.

    1983-11-18

    The City of Longview can obtain significant fuel savings benefits by converting a portion of their vehicle fleet to operate on either compressed natural gas (CNG) or liquid petroleum gas (LPG) fuels. The conversion of 41 vehicles including police units, sedans, pickups, and light duty trucks to CNG use would offset approximately 47% of the city's 1982 gasoline consumption. The CNG conversion capital outlay of $115,000 would be recovered through fuel cost reductions. The Cascade Natural Gas Corporation sells natural gas under an interruptible tariff for $0.505 per therm, equivalent to slightly less than one gallon of gasoline. The citymore » currently purchases unleaded gasoline at $1.115 per gallon. A payback analysis indicates that 39.6 months are required for the CNG fuel savings benefits to offset the initial or first costs of the conversion. The conversion of fleet vehicles to liquid petroleum gas (LPG) or propane produces comparable savings in vehicle operating costs. The conversion of 59 vehicles including police units, pickup and one ton trucks, street sweepers, and five cubic yard dump trucks would cost approximately $59,900. The annual purchase of 107,000 gallons of propane would offset the consumption of 96,300 gallons of gasoline, or approximately 67% of the city's 1982 usage. Propane is currently retailing for $0.68 to $0.74 per gallon. A payback analysis indicates that 27.7 months are required for the fuel savings benefits to offset the initial LPG conversion costs.« less

  1. Energy and life-cycle cost analysis of a six-story office building

    NASA Astrophysics Data System (ADS)

    Turiel, I.

    1981-10-01

    An energy analysis computer program, DOE-2, was used to compute annual energy use for a typical office building as originally designed and with several energy conserving design modifications. The largest energy use reductions were obtained with the incorporation of daylighting techniques, the use of double pane windows, night temperature setback, and the reduction of artificial lighting levels. A life-cycle cost model was developed to assess the cost-effectiveness of the design modifications discussed. The model incorporates such features as inclusion of taxes, depreciation, and financing of conservation investments. The energy conserving strategies are ranked according to economic criteria such as net present benefit, discounted payback period, and benefit to cost ratio.

  2. Energy analysis of coal, fission, and fusion power plants

    NASA Astrophysics Data System (ADS)

    Tsoulfanidis, N.

    1981-04-01

    The method of net energy analysis has been applied to coal, fission, and fusion power plants. Energy consumption over the lifetime of the plants has been calculated for construction, operation and maintenance, fuel, public welfare, and land use and restoration. Thermal and electric energy requirements were obtained separately for each energy consuming sector. The results of the study are presented in three ways: total energy requirements, energy gain ratio, and payback periods. All three types of power plants are net producers of energy. The coal and fusion power plants are superior to fission plants from the energy efficiency point of view. Fission plants will improve considerably if the centrifuge replaces the gaseous diffusion as a method of enrichment.

  3. Alterations of chemical composition, construction cost and payback time in needles of Masson pine (Pinus massoniana L.) trees grown under pollution.

    PubMed

    Liu, Nan; Guan, Lan-Lan; Sun, Fang-Fang; Wen, Da-Zhi

    2014-07-01

    Previous studies show that Masson pine (Pinus massoniana L.) stands grown at the industrially-polluted site have experienced unprecedented growth decline, but the causal mechanisms are poorly understood. In this study, to understand the mechanisms of growth decline of Mason pine strands under pollution stresses, we determined the reactive oxygen species levels and chemical composition of the current-year (C) and one-year-old (C + 1) needles, and calculated the needle construction costs (CCmass) of Masson pine trees grown at an industrially-polluted site and an unpolluted remote site. Pine trees grown at the polluted site had significantly higher levels of hydroxyl radical and superoxide anion in their needles than those grown at the unpolluted site, and the former trees eventually exhibited needle early senescence. The contents of lipids, soluble phenolics and lignins in C and C + 1 needles were significantly higher at the polluted site than at the unpolluted site, but the total amounts of non-construction carbohydrates were lower in non-polluted needles than in polluted needles. Elevated levels of the reactive oxygen species and early senescence in polluted needles together led to significant increases in CCmass and a longer payback time. We infer that the lengthened payback time and needle early senescence under pollution stress may reduce the Masson pine tree growth and consequently accelerate tree decline.

  4. Demonstration Assessment of Light-Emitting Diode Parking Structure Lighting at U.S. Department of Labor Headquarters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    2013-03-01

    This report documents a solid-state lighting (SSL) technology demonstration at the parking structure of the U.S. Department of Labor (DOL) Headquarters in Washington, DC, in which light-emitting diode (LED) luminaires were substituted for the incumbent high-pressure sodium (HPS) luminaires and evaluated for relative light quantity and performance. The demonstration results show energy savings of 52% from the initial conversion of HPS to the LED product. These savings were increased to 88% by using occupancy sensor controls that were ultimately set to reduce power to 10% of high state operation after a time delay of 2.5 minutes. Because of the relativelymore » high cost of the LED luminaires at their time of purchase for this project (2010), the simple payback periods were 6.5 years and 4.9 years for retrofit and new construction scenarios, respectively. Staff at DOL Headquarters reported high satisfaction with the operation of the LED product.« less

  5. Back to the Earth.

    ERIC Educational Resources Information Center

    Abnee, Conn

    1999-01-01

    Discusses how schools can use geothermal technology to conserve energy and save money. How geothermal climate control works and its payback are examined, and examples of development and use are highlighted. (GR)

  6. "Simplify, Simplify."

    ERIC Educational Resources Information Center

    Stump, William P.

    1983-01-01

    An integrated electronic system combines individual monitoring and control functions into one economical unit that earns a rapid payback by automatically managing and controlling energy usage, building systems, and security and maintenance tasks. (MLF)

  7. Economic Viability of Pumped-Storage Power Plants Equipped with Ternary Units and Considering Hydraulic Short-Circuit Operation

    NASA Astrophysics Data System (ADS)

    Chazarra, Manuel; Pérez-Díaz, Juan I.; García-González, Javier

    2017-04-01

    This paper analyses the economic viability of pumped-storage hydropower plants equipped with ternary units and considering hydraulic short-circuit operation. The analysed plant is assumed to participate in the day-ahead energy market and in the secondary regulation service of the Spanish power system. A deterministic day-ahead energy and reserve scheduling model is used to estimate the maximum theoretical income of the plant assuming perfect information of the next day prices and the residual demand curves of the secondary regulation reserve market. Results show that the pay-back periods with and without the hydraulic short-circuit operation are significantly lower than their expected lifetime and that the pay-back periods can be reduced with the inclusion of the hydraulic short-circuit operation.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Geet, Otto

    NREL has developed a methodology to prioritize which data center cooling systems could be upgraded for better efficiency based on estimated cost savings and economics. The best efficiency results are in cool or dry climates where 'free' economizer or evaporative cooling can provide most of the data center cooling. Locations with a high cost of energy and facilities with high power usage effectiveness (PUE) are also good candidates for data center cooling system upgrades. In one case study of a major cable provider's data centers, most of the sites studied had opportunities for cost-effective cooling system upgrades with payback periodmore » of 5 years or less. If the cable provider invested in all opportunities for upgrades with payback periods of less than 15 years, it could save 27% on annual energy costs.« less

  9. Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  10. Present capabilities and future requirements for computer-aided geometric modeling in the design and manufacture of gas turbine

    NASA Technical Reports Server (NTRS)

    Caille, E.; Propen, M.; Hoffman, A.

    1984-01-01

    Gas turbine engine design requires the ability to rapidly develop complex structures which are subject to severe thermal and mechanical operating loads. As in all facets of the aerospace industry, engine designs are constantly driving towards increased performance, higher temperatures, higher speeds, and lower weight. The ability to address such requirements in a relatively short time frame has resulted in a major thrust towards integrated design/analysis/manufacturing systems. These computer driven graphics systems represent a unique challenge, with major payback opportunities if properly conceived, implemented, and applied.

  11. Life-cycle economics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lunde, P.J.

    1982-09-01

    In a continuation of previous economic analyses, life-cycle economics of solar projects are discussed using the concept of net present value (NPV) or net worth. The discount rate is defined and illustrated and a life-cycle analysis is worked out based on no down payment and a 25-year loan. The advantages of rising NPV are discussed and illustrated using an energy conserving $100 storm window as an example. Real payback period is discussed and it is concluded that NPV is the only valid method for the evaluation of an investment. Return on investment is cited as a satisfactory alternative method. (MJJ)

  12. 34 CFR 263.8 - What are the payback requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... participant performs. (Approved by the Office of Management and Budget under control number 1810-0580... for which training was actually received under the Professional Development program. (c) The cash...

  13. Product Assurance Targeted to Meet Mission Objectives

    NASA Technical Reports Server (NTRS)

    Mclaughlin, Diane

    1991-01-01

    Topics concerning the Common Lunar Lander for the Space Exploration Initiative are covered and include the following: product assurance tools and supports; project goals; and product assurance structured for optimal payback.

  14. Solar energy system economic evaluation for Seeco Lincoln, Lincoln, Nebraska

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The economic analysis of the solar energy system that was installed at Lincoln, Nebraska is developed for this and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over projected twenty year life: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  15. WaterSense at Work

    EPA Pesticide Factsheets

    Each of the 36 BMPs provides an overview of the technology, tips for operation, maintenance, and user education, options for retrofits and replacements, and calculations for potential water, energy, and dollar savings and payback periods.

  16. The School Advanced Ventilation Engineering Software (SAVES)

    EPA Pesticide Factsheets

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  17. Evolution of the U.S. Energy Service Company Industry: Market Size and Project Performance from 1990-2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Peter; Goldman, Charles A.; Satchwell, Andrew

    2012-05-08

    The U.S. energy service company (ESCO) industry is an example of a private sector business model where energy savings are delivered to customers primarily through the use of performance-based contracts. This study was conceived as a snapshot of the ESCO industry prior to the economic slowdown and the introduction of federal stimulus funding mandated by enactment of the American Recovery and Reinvestment Act of 2009 (ARRA). This study utilizes two parallel analytic approaches to characterize ESCO industry and market trends in the U.S.: (1) a “top-down” approach involving a survey of individual ESCOs to estimate aggregate industry activity and (2)more » a “bottom-up” analysis of a database of -3,265 projects (representing over $8B in project investment) that reports market trends including installed EE retrofit strategies, project installation costs and savings, project payback times, and benefit-cost ratios over time. Despite the onset of an economic recession, the U.S. ESCO industry managed to grow at about 7% per year between 2006 and 2008. ESCO industry revenues are relatively small compared to total U.S. energy expenditures (about $4.1 billion in 2008), but ESCOs anticipated accelerated growth through 2011 (25% per year). We found that 2,484 ESCO projects in our database generated -$4.0 billion ($2009) in net, direct economic benefits to their customers. We estimate that the ESCO project database includes about 20% of all U.S. ESCO market activity from 1990-2008. Assuming the net benefits per project are comparable for ESCO projects that are not included in the LBNL database, this would suggest that the ESCO industry has generated -$23 billion in net direct economic benefits for customers at projects installed between 1990 and 2008. We found that nearly 85% of all public and institutional projects met or exceeded the guaranteed level of savings. We estimated that a typical ESCO project generated $1.5 dollars of direct benefits for every dollar of customer investment. There is empirical evidence confirming that the industry is responding to customer demand by installing more comprehensive and complex measures—including onsite generation and measures to address deferred maintenance—but this evolution has significant implications for customer project economics, especially at K-12 schools. We found that the median simple payback time has increased from 1.9 to 3.2 years in private sector projects since the early-to-mid 1990s and from 5.2 to 10.5 years in public sector projects for the same time period.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frischknecht, Rolf; Heath, Garvin; Raugei, Marco

    Life Cycle Assessment (LCA) is a structured, comprehensive method of quantifying material- and energy-flows and their associated emissions caused in the life cycle of goods and services. The ISO 14040 and 14044 standards provide the framework for LCA. However, this framework leaves the individual practitioner with a range of choices that can affect the results and thus the conclusions of an LCA study. The current IEA guidelines were developed to provide guidance on assuring consistency, balance, and quality to enhance the credibility and reliability of the results from LCAs on photovoltaic (PV) electricity generation systems. The guidelines represent a consensusmore » among the authors - PV LCA experts in North America, Europe, and Asia - for assumptions made on PV performance, decisions on process input and emissions allocation, methods of analysis, and reporting of the results. Guidance is given on PV-specific parameters used as inputs in LCA and on choices and assumptions in life cycle inventory (LCI) data analysis and on implementation of modeling approaches. A consistent approach towards system modeling, the functional unit, the system boundaries, water use modeling and the allocation aspects enhances the credibility of PV electricity LCA studies and enables balanced LCA-based comparisons of different electricity producing technologies. The document discusses metrics like greenhouse gas emissions (GHG), cumulative energy demand (CED), acidification potential (AP), ozone depletion potential (ODP), human toxicity, ecotoxicity and ionizing radiation. Guidance is given for the definition of the energy payback time (EPBT), the nonrenewable energy payback time (NREPBT), and the impact mitigation potentials (IMP). The indicator energy return on investment (EROI) is described in a separate International Energy Agency (IEA) PV Power Systems (PVPS) Task 12 report (Raugei et al. 2015). The guidelines on the reporting and communication of the results serve the need for producing clear, comprehensive and transparent reports.« less

  19. Building America Case Study: Philadelphia Housing Authority Energy-Efficiency Turnover Protocols, Philadelphia, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-02-01

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16 percent and duct leakage reductions averaged 23 percent. Total source energy consumption savings due to implemented measures was estimated at 3-10 percent based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less

  20. Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-08-01

    More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations atmore » the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less

  1. Public Housing: A Tailored Approach to Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Podorson, D.

    2016-02-18

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16% and duct leakage reductions averaged 23%. Total source energy consumption savings due to implemented measures was estimated at 3-10% based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less

  2. Solar energy system economic evaluation for Solaron Akron, Akron, Ohio

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The economic analysis of the solar energy system that was installed at Akron, Ohio is developed for this and four other sites typical of a wide range of environmental and economic conditions. The analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results show that only in Albuquerque, New Mexico, where insolation is 1828 Btu/sq ft/day and the conventional energy cost is high, is this solar energy system marginally profitable.

  3. Solar energy system economic evaluation for Seeco Lincoln, Lincoln, Nebraska. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-09-01

    The economic analysis of the solar energy system that was installed at Lincoln, Nebraska is developed for this and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over projected twenty year life: life cycle savings, year of positive savings and year of payback formore » the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.« less

  4. Performance and economic analysis of a plug and play regenerative brake for improving energy efficiency for traction elevators

    NASA Astrophysics Data System (ADS)

    Jeraputra, Chuttchaval; Tiptipakorn, Supun

    2017-05-01

    This paper presents performance and economic analysis of a plug and play regenerative brake for improving energy efficiency for traction elevators. The proposed regenerative brake recycles the energy loss of a dynamic brake and feeds into the grid while an elevator inverter is operating in the braking mode. According to field measurement of energy consumption, it reveals that the efficiency can be improved as much as 18%. The prototype of a regenerative brake 12 kW, 400V, 3ϕ is developed and tested on an elevator simulator. It is shown that it can transfer energy out of a DC capacitor before the dynamic brake kicks in. Further, an economic analysis is provided to carry out the payback period and the present worth equivalent to confirm economic feasibility.

  5. Cost analysis of new and retrofit hot-air type solar assisted heating systems

    NASA Technical Reports Server (NTRS)

    Stewart, R. D.; Hawkins, B. J.

    1978-01-01

    A detailed cost analysis/cost improvement study was performed on two Department of Energy/National Aeronautics and Space Administration operational test sites to determine actual costs and potential cost improvements of new and retrofit hot air type, solar assisted heating and hot water systems for single family sized structures. This analysis concentrated on the first cost of a system which included procurement, installation, and integration of a solar assisted heating and hot water system on a new or retrofit basis; it also provided several cost projections which can be used as inputs to payback analyses, depending upon the degree of optimism or future improvements assumed. Cost definitions were developed for five categories of cost, and preliminary estimates were developed for each. The costing methodology, approach, and results together with several candidate low cost designs are described.

  6. Solar energy system economic evaluation final report for SEMCO-Loxahatchee, Loxahatchee National Wildlife refuge, Palm Beach County, Florida

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Economic analysis of the solar energy system installed at Loxahatchee, was developed for Loxahatchee and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis was accomplished based on the technical and economic models in the f Chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system costs over a projected twenty year life, life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables was also investigated. The results demonstrate that the solar energy system is economically viable at all of the five sites for which the analysis was conducted.

  7. Solar energy system economic evaluation: IBM System 2, Togus, Maine

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The economic analysis of the solar energy system, is developed for Torgus and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f-chart design procedure with inputs taken on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over a projected twenty year life, life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results demonstrate that the solar energy system is economically viable at all of the five sites for which the analysis was conducted.

  8. Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-07-01

    The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for themore » laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  9. A Life Cycle Assessment and Economic Analysis of Wind Turbines Using Monte Carlo Simulation

    DTIC Science & Technology

    2003-03-01

    1,521 1,579 2,699 2,817 1,683 1,849 2,037 1,915 2,008 94849 MI Alpena 806 948 1,110 1,142 1,953 2,068 1,128 1,269 1,434 1,324 1,405 94847 MI Detroit...AK Anchorage, AK Payback (years) 115 0 10 20 30 40 50 60 70 80 Lansing, MI Houghton, MI Grand Rapids, MI Flint, MI Detroit, MI Alpena , MI Portland...Grand Rapids, MI Flint, MI Detroit, MI Alpena , MI Portland, ME Caribou, ME Baltimore, MD Worchester, MA Boston, MA Shreveport, LA New Orleans, LA Lake

  10. Systems Analysis and Design for Decision Support Systems on Economic Feasibility of Projects

    NASA Astrophysics Data System (ADS)

    Balaji, S. Arun

    2010-11-01

    This paper discuss about need for development of the Decision Support System (DSS) software for economic feasibility of projects in Rwanda, Africa. The various economic theories needed and the corresponding formulae to compute payback period, internal rate of return and benefit cost ratio of projects are clearly given in this paper. This paper is also deals with the systems flow chart to fabricate the system in any higher level computing language. The various input requirements from the projects and the output needed for the decision makers are also included in this paper. The data dictionary used for input and output data structure is also explained.

  11. Solar silicon via the Dow Corning process

    NASA Technical Reports Server (NTRS)

    Hunt, L. P.; Dosaj, V. D.

    1979-01-01

    Technical feasibility for high volume production of solar cell-grade silicon is investigated. The process consists of producing silicon from pure raw materials via the carbothermic reduction of quartz. This silicon was then purified to solar grade by impurity segregation during Czochralski crystal growth. Commercially available raw materials were used to produce 100 kg quantities of silicon during 60 hour periods in a direct arc reactor. This silicon produced single crystalline ingot, during a second Czochralski pull, that was fabricated into solar cells having efficiencies ranging from 8.2 percent to greater than 14 percent. An energy analysis of the entire process indicated a 5 month payback time.

  12. Cost Benefit Analysis Modeling Tool for Electric vs. ICE Airport Ground Support Equipment – Development and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Francfort; Kevin Morrow; Dimitri Hochard

    2007-02-01

    This report documents efforts to develop a computer tool for modeling the economic payback for comparative airport ground support equipment (GSE) that are propelled by either electric motors or gasoline and diesel engines. The types of GSE modeled are pushback tractors, baggage tractors, and belt loaders. The GSE modeling tool includes an emissions module that estimates the amount of tailpipe emissions saved by replacing internal combustion engine GSE with electric GSE. This report contains modeling assumptions, methodology, a user’s manual, and modeling results. The model was developed based on the operations of two airlines at four United States airports.

  13. Case Study for the ARRA-funded Ground Source Heat Pump Demonstration at Denver Museum of Nature & Science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Piljae; Liu, Xiaobing

    High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects were competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This report highlights the findings of a case study of one such GSHP demonstration projects that uses a recycled water heat pump (RWHP) system installed at the Denver Museum of Nature & Science in Denver, Colorado. Themore » RWHP system uses recycled water from the city’s water system as the heat sink and source for a modular water-to-water heat pump (WWHP). This case study was conducted based on the available measured performance data from December 2014 through August 2015, utility bills of the building in 2014 and 2015, construction drawings, maintenance records, personal communications, and construction costs. The annual energy consumption of the RWHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional VAV system using a water-cooled chiller and a natural gas fired boiler, both of which have the minimum energy efficiencies allowed by ASHRAE 90.1-2010. The comparison was made to determine energy savings, operating cost savings, and CO2 emission reductions achieved by the RWHP system. A cost analysis was performed to evaluate the simple payback of the RWHP system. Summarized below are the results of the performance analysis, the learned lessons, and recommended improvement in the operation of the RWHP system.« less

  14. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    NASA Astrophysics Data System (ADS)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  15. 77 FR 13132 - Proposed Collection: Comment Request; Revision “PHS Applications and Pre-Award Reporting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-05

    ... individuals to indicate the start of their NRSA awards. The PHS 6031 Payback Agreement is used by individuals... activated and trainees appointed. Affected Public: Universities and other research institutions; Business or...

  16. Choosing a Geothermal as an HVAC System.

    ERIC Educational Resources Information Center

    Lensenbigler, John D.

    2002-01-01

    Describes the process of selecting and installing geothermal water source heat pumps for new residence halls at Johnson Bible College in Knoxville, Tennessee, including choosing the type of geothermal design, contractors, and interior equipment, and cost and payback. (EV)

  17. 78 FR 49532 - Request for Public Comment: 30-Day Proposed Information Collection: Application for Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... Scholarship recipients; monitor the academic performance of recipients; and to place recipients at payback... Initial Program Progress Report 1200 1 1200 0.13 ( 8 min) 160 (IHS-856-8). Notification of Academic...

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, George

    VICE 2.0 is the second generation of the VICE financial model developed by the National Renewable Energy Laboratory for fleet managers to assess the financial soundness of converting their fleets to run on CNG. VICE 2.0 uses a number of variables for infrastructure and vehicles to estimate the business case for decision-makers when considering CNG as a vehicle fuel. Enhancements in version 2.0 include the ability to select the project type (vehicles and infrastructure or vehicle acquisitions only), and to decouple vehicle acquisition from the infrastructure investment, so the two investments may be made independently. Outputs now include graphical presentationsmore » of investment cash flow, payback period (simple and discounted), petroleum displacement (annual and cumulative), and annual greenhouse gas reductions. Also, the Vehicle Data are now built around several common conventionally fueled (gasoline and diesel) fleet vehicles. Descriptions of the various model sections and available inputs follow. Each description includes default values for the base-case business model, which was created so economic sensitivities can be investigated by altering various project parameters one at a time.« less

  19. Public Housing: A Tailored Approach to Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Conlin, Francis; Podorson, David

    2014-06-01

    More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations when unitsmore » are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation 10 ten housing units. Total source energy consumption savings was estimated at 6%-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less

  20. Economic and Environmental Assessment of a 1 MW Grid Connected Rooftop Solar PV System for Energy Efficient Building in Bangladesh

    NASA Astrophysics Data System (ADS)

    Chakraborty, Sanjib; Hosain, Rubayet; Rahman, Toufiqur; Rabbi, Ahmead Fazle

    This paper evaluates the potentiality of a 1 MW grid connected rooftop solar PV system for an Energy Efficient Building in Bangladesh, which was estimated by utilizing NASA SSE solar radiation data, PVsyst simulation software and RETScreen simulation software. Economic and environmental viability for a ten-storied building with roof area of 6,500 m2 in the Capital City of Bangladesh, Dhaka was assessed by using the RETScreen simulation software. The yearly electricity production of the proposed system was 1,581 MWh estimated by PVsyst where the technical prospective of gird-connected solar PV in Bangladesh was calculated as about 50,174 MW. The economic assessments were determined the simple payback in such a way that the generated electricity first fulfills the demand of the building, and then the rest of the energy is supplied to the grid. The result indicates that the roof top solar PV system for an Energy efficient building in Dhaka city has a favorable condition for development both in economic and environmental point of view.

  1. Economic Evaluation of the Production Magnesium Oxide Nanoparticles via Liquid-Phase Route

    NASA Astrophysics Data System (ADS)

    Nandiyanto, A. B. D.; Fariansyah, R.; Ramadhan, M. F.; Abdullah, A. G.; Widiaty, I.

    2018-02-01

    The purpose of this study was to evaluate the production of magnesium oxide (MgO) nanoparticles. The evaluation was done in two perspectives: engineering and economic evaluation. The engineering perspective concerned about the analysis of the production rate based on the available apparatuses and raw materials, completed with mass balance calculation. The economic analysis was conducted based on several economic parameters: gross profit margin (GPM), internal return rate (IRR), payback period (PBP), cumulative net present value (CNPV), break even point (BEP), and profit to investment (PI). The engineering perspective showed that the production of MgO is feasibly done in small scale industry. This is verified by the potential production using current available apparatuses and raw materials in the market. Economic analysis obtained that the present project is profitable. But, for some cases, further studies must be done to get the present production process is attractive for investor.

  2. 34 CFR 263.8 - What are the payback requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EDUCATION, DEPARTMENT OF EDUCATION INDIAN EDUCATION DISCRETIONARY GRANT PROGRAMS Professional Development... Professional Development program are required to— (1) Sign an agreement, at the time of selection for training... for which training was actually received under the Professional Development program. (c) The cash...

  3. Can biofuels be a solution to climate change? The implications of land use change-related emissions for policy

    PubMed Central

    Khanna, Madhu; Crago, Christine L.; Black, Mairi

    2011-01-01

    Biofuels have gained increasing attention as an alternative to fossil fuels for several reasons, one of which is their potential to reduce the greenhouse gas (GHG) emissions from the transportation sector. Recent studies have questioned the validity of claims about the potential of biofuels to reduce GHG emissions relative to the liquid fossil fuels they are replacing when emissions owing to direct (DLUC) and indirect land use changes (ILUC) that accompany biofuels are included in the life cycle GHG intensity of biofuels. Studies estimate that the GHG emissions released from ILUC could more than offset the direct GHG savings by producing biofuels and replacing liquid fossil fuels and create a ‘carbon debt’ with a long payback period. The estimates of this payback period, however, vary widely across biofuels from different feedstocks and even for a single biofuel across different modelling assumptions. In the case of corn ethanol, this payback period is found to range from 15 to 200 years. We discuss the challenges in estimating the ILUC effect of a biofuel and differences across biofuels, and its sensitivity to the assumptions and policy scenarios considered by different economic models. We also discuss the implications of ILUC for designing policies that promote biofuels and seek to reduce GHG emissions. In a first-best setting, a global carbon tax is needed to set both DLUC and ILUC emissions to their optimal levels. However, it is unclear whether unilateral GHG mitigation policies, even if they penalize the ILUC-related emissions, would increase social welfare and lead to optimal emission levels. In the absence of a global carbon tax, incentivizing sustainable land use practices through certification standards, government regulations and market-based pressures may be a viable option for reducing ILUC. PMID:22482030

  4. Can biofuels be a solution to climate change? The implications of land use change-related emissions for policy.

    PubMed

    Khanna, Madhu; Crago, Christine L; Black, Mairi

    2011-04-06

    Biofuels have gained increasing attention as an alternative to fossil fuels for several reasons, one of which is their potential to reduce the greenhouse gas (GHG) emissions from the transportation sector. Recent studies have questioned the validity of claims about the potential of biofuels to reduce GHG emissions relative to the liquid fossil fuels they are replacing when emissions owing to direct (DLUC) and indirect land use changes (ILUC) that accompany biofuels are included in the life cycle GHG intensity of biofuels. Studies estimate that the GHG emissions released from ILUC could more than offset the direct GHG savings by producing biofuels and replacing liquid fossil fuels and create a 'carbon debt' with a long payback period. The estimates of this payback period, however, vary widely across biofuels from different feedstocks and even for a single biofuel across different modelling assumptions. In the case of corn ethanol, this payback period is found to range from 15 to 200 years. We discuss the challenges in estimating the ILUC effect of a biofuel and differences across biofuels, and its sensitivity to the assumptions and policy scenarios considered by different economic models. We also discuss the implications of ILUC for designing policies that promote biofuels and seek to reduce GHG emissions. In a first-best setting, a global carbon tax is needed to set both DLUC and ILUC emissions to their optimal levels. However, it is unclear whether unilateral GHG mitigation policies, even if they penalize the ILUC-related emissions, would increase social welfare and lead to optimal emission levels. In the absence of a global carbon tax, incentivizing sustainable land use practices through certification standards, government regulations and market-based pressures may be a viable option for reducing ILUC.

  5. Analysis and evaluation in the production process and equipment area of the low-cost solar array project

    NASA Technical Reports Server (NTRS)

    Goldman, H.; Wolf, M.

    1979-01-01

    The energy consumed in manufacturing silicon solar cell modules was calculated for the current process, as well as for 1982 and 1986 projected processes. In addition, energy payback times for the above three sequences are shown. The module manufacturing energy was partitioned two ways. In one way, the silicon reduction, silicon purification, sheet formation, cell fabrication, and encapsulation energies were found. In addition, the facility, equipment, processing material and direct material lost-in-process energies were appropriated in junction formation processes and full module manufacturing sequences. A brief methodology accounting for the energy of silicon wafers lost-in-processing during cell manufacturing is described.

  6. A financial feasibility model of gasification and anaerobic digestion waste-to-energy (WTE) plants in Saudi Arabia.

    PubMed

    Hadidi, Laith A; Omer, Mohamed Mahmoud

    2017-01-01

    Municipal Solid Waste (MSW) generation in Saudi Arabia is increasingly growing at a fast rate, as it hurtles towards ever increasing urban development coupled with rapid developments and expanding population. Saudi Arabia's energy demands are also rising at a faster rate. Therefore, the importance of an integrated waste management system in Saudi Arabia is increasingly rising and introducing Waste to Energy (WTE) facilities is becoming an absolute necessity. This paper analyzes the current situation of MSW management in Saudi Arabia and proposes a financial model to assess the viability of WTE investments in Saudi Arabia in order to address its waste management challenges and meet its forecasted energy demands. The research develops a financial model to investigate the financial viability of WTE plants utilizing gasification and Anaerobic Digestion (AD) conversion technologies. The financial model provides a cost estimate of establishing both gasification and anaerobic digestion WTE plants in Saudi Arabia through a set of financial indicators, i.e. net present value (NPV), internal rate of return (IRR), modified internal rate of return (MIRR), profitability index (PI), payback period, discounted payback period, Levelized Cost of Electricity (LCOE) and Levelized Cost of Waste (LCOW). Finally, the analysis of the financial model reveals the main affecting factors of the gasification plants investment decision, namely: facility generation capacity, generated electricity revenue, and the capacity factor. Similarly, the paper also identifies facility waste capacity and the capacity factor as the main affecting factors on the AD plants' investment decision. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Alternative Fuels Data Center: Tools

    Science.gov Websites

    Calculator Compare cost of ownership and emissions for most vehicle models. mobile Petroleum Reduction ROI and payback period for natural gas vehicles and infrastructure. AFLEET Tool Calculate a fleet's , hydrogen, or fuel cell infrastructure. GREET Fleet Footprint Calculator Calculate your fleet's petroleum

  8. MOD control center automated information systems security evolution

    NASA Technical Reports Server (NTRS)

    Owen, Rich

    1991-01-01

    The role of the technology infusion process in future Control Center Automated Information Systems (AIS) is highlighted. The following subject areas are presented in the form of the viewgraphs: goals, background, threat, MOD's AISS program, TQM, SDLC integration, payback, future challenges, and bottom line.

  9. Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-11-01

    This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryersmore » used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  10. Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-12-01

    The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers usedmore » for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  11. Cost effective solar hot water system for Econo-Travel Motor Hotel located at Woodbrdge, VA. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-11-01

    The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 13317 Gordon Boulevard, Woodbridge, Virginia is given. The description of the system along with the final breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 7.2 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used formore » the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  12. Industry's tireless eyes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-08-01

    This article reports that there are literally hundreds of machine vision systems from which to choose. They range in cost from $10,000 to $1,000,000. Most have been designed for specific applications; the same systems if used for a different application may fail dismally. How can you avoid wasting money on inferior, useless, or nonexpandable systems. A good reference is the Automated Vision Association in Ann Arbor, Mich., a trade group comprised of North American machine vision manufacturers. Reputable suppliers caution users to do their homework before making an investment. Important considerations include comprehensive details on the objects to be viewed-thatmore » is, quantity, shape, dimension, size, and configuration details; lighting characteristics and variations; component orientation details. Then, what do you expect the system to do-inspect, locate components, aid in robotic vision. Other criteria include system speed and related accuracy and reliability. What are the projected benefits and system paybacks.. Examine primarily paybacks associated with scrap and rework reduction as well as reduced warranty costs.« less

  13. [Exploring models for the assessment of the economic, social, political, and scientific impact of health research].

    PubMed

    Macías-Angel, Beatriz; Agudelo-Calderón, Carlos A

    2015-05-01

    Health research produces effects on the health of populations. This document approaches the frameworks and the models used by developed countries to assess the impact of health research through documentary analysis of research with the highest impact. With this, it was possible to identify two guiding axes of analysis: one having to do with focus, and the other having to do with emphasis. With these, the published models, their uses, their reach, and their origins are related. Our study brings awareness to the features they have and the areas in which Colombia could implement them. We found that the framework for evaluating health research known as the "payback model" is a model for monitoring research that tracks the process and research results with multidimensional categorization of the impacts of research.

  14. Action Research: Enhancing Classroom Practice and Fulfilling Educational Responsibilities

    ERIC Educational Resources Information Center

    Young, Mark R.; Rapp, Eve; Murphy, James W.

    2010-01-01

    Action Research is an applied scholarly paradigm resulting in action for continuous improvement in our teaching and learning techniques offering faculty immediate classroom payback and providing documentation of meeting our educational responsibilities as required by AACSB standards. This article reviews the iterative action research process of…

  15. Energy savings opportunity survey at Walter Reed Army Medical Center, Washington, DC. Final Submittal report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1987-10-22

    This Energy Savings Opportunity Survey (ESOS) was performed for sixteen (16) buildings at Walter Reed Army Medical Center (WPAMC) in Washington, D.C. This survey was intended to reevaluate and update projects from a previous Energy Engineering Analysis Program (EEAP) survey performed at WRAMC. However, the previous EEAP survey was determined by the contracting officer to be incomplete and not worthy of further consideration. Therefore, this survey involved the complete reevaluation of the buildings to determine their potential energy cost savings. Six (6) projects and nine (9) low cost/no cost energy conservation opportunities (ECO`s) are recommended for implementation in the buildings.more » These projects and ECO`s are projected to annually save $448,263 at an implementation cost of $891,659. The simple payback (i.e., implementation cost divided by cost savings) for the recommendations in the survey is 1.99 years. The two (2) projects with the greatest cost savings are a stack heat recovery system (Project Number 5) and HVAC modifications (Project Number 1). These two (2) projects will provide 67% of the projected total savings for the survey. The sixteen (16) buildings in this survey represent only 22% of the total floor area of the Walter Reed Army Medical Center complex. It is believed that significant potential energy cost savings amounting to two (2) million dollars may be achieved in the remaining buildings in the complex not included in this survey. Specifically it is believed the main hospital building contains many opportunities for substantial cost savings.« less

  16. Energy Efficiency Opportunities in Highway Lodging Buildings: Development of 50% Energy Savings Design Technology Packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Wei; Gowri, Krishnan; Thornton, Brian A.

    2010-06-30

    This paper presents the process, methodology, and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document that provides specific recommendations for achieving 50% energy savings in roadside motels (highway lodging) above the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004. This 50% solution represents a further step toward realization of the U.S. Department of Energy’s net-zero energy building goal, and go beyond the 30% savings in the Advanced Energy Design Guide series (upon which this work was built). This work can serve as the technical feasibility study for the development of a 50%more » saving Advanced Energy Design Guide for highway lodging, and thus should greatly expedite the development process. The purpose of this design package is to provide user-friendly design assistance to designers, developers, and owners of highway lodging properties. It is intended to encourage energy-efficient design by providing prescriptive energy-efficiency recommendations for each climate zone that attains the 50% the energy savings target. This paper describes the steps that were taken to demonstrate the technical feasibility of achieving a 50% reduction in whole-building energy use with practical and commercially available technologies. The energy analysis results are presented, indicating the recommended energy-efficient measures achieved a national-weighted average energy savings of 55%, relative to Standard 90.1-2004. The cost-effectiveness of the recommended technology package is evaluated and the result shows an average simple payback of 11.3 years.« less

  17. Steam dispatching control system demonstration at Fort Benjamin Harrison. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Diks, C.L.; Moshage, R.E.; Lin, M.C.

    1993-07-01

    Currently most Army Central steam heating systems operate by maintaining a constant steam pressure regardless of actual steam demand. This method offers some operational convenience, but is often the cause of significant energy losses. Researchers at the U.S. Army Construction Engineering Research Laboratories (USACERL) have investigated the Steam Dispatching Control System (SDCS), a control system that lowers supply steam pressure-and therefore steam temperature-to slightly above the amount needed to meet the steam demand. The lower Steam temperature and reduction in steam loss (from leaks and faulty traps) result in lower heat losses and higher energy savings. Limiting steam pressure canmore » diminish the amount of excess heat loss in the distribution system while still meeting the demand. The Army's Facilities Engineering Applications Program (FEAP) chose Fort Benjamin Harrison, IN, as the Army demonstration site for SDCS. Researchers found that use of SDCS is technically and economically viable improvement over current operating procedures. Analysis based on demonstration results show that the simple payback for SDCS is less than 1 year. The results of this demonstration are generally applicable to installations with a large central heating plant and a substantial steam distribution system. Findings, indicate that energy savings form SDCS are significant regardless of what type of fuel powers the boiler. The authors note that, during the initial evaluation of a potential SDCS application, attention must be paid to the condensate return to ensure that it will operate properly. Fort Benjamin Harrison, IN, Steam Dispatching Control System(SDCS), Central heating plants, energy conservation.« less

  18. Round-bale feeder design affects hay waste and economics during horse feeding.

    PubMed

    Martinson, K; Wilson, J; Cleary, K; Lazarus, W; Thomas, W; Hathaway, M

    2012-03-01

    Many horse owners find round bales convenient, less labor intensive, and more affordable than other hay types, but report an inability to control horse BW gain and excessive hay waste. The objectives were to compare hay waste, hay intake, and payback of 9 round-bale feeders and a no-feeder control when used during horse feeding. Nine round-bale feeders were tested: Cinch Net, Cone, Covered Cradle, Hayhut, Hay Sleigh, Ring, Tombstone, Tombstone Saver, and Waste Less. Each feeder design was placed on the ground in a dirt paddock. Five groups of 5 horses were fed in rotation for a 4-d period with each feeder. Every fourth day, groups were rotated among paddocks and a new round bale was placed in each feeder. In the 5 paddocks used, 5 feeders were installed for d 1 through 20, and the remaining 4 feeders and no-feeder control were installed for d 21 through 40. Groups of horses were sequentially assigned to feeders using two 5 × 5 Latin squares, the first for d 1 through 20, the second for d 21 through 40. Horse groups of similar age, BW, breed, and sex were formed from 25 Quarter Horse and Thoroughbred geldings and open mares (means: 11 yr; 541 kg of BW). Hay on the ground surrounding the feeder was collected daily, dried, and weighed. The total amount of hay removed around each feeder for a 4-d period was considered waste. Dry matter intake was estimated as the difference between hay disappearance and waste. Number of months for the reduction in waste to repay feeder cost (payback) were calculated using hay valued at $110/t, and improved feeder efficiency over the control. Feeder design did not affect hay intake (P > 0.05); all feeders resulted in an estimated hay intake of 2.0 to 2.4% BW; the no-feeder control resulted in a reduced intake of 1.3% BW (P = 0.001). Mean percentage of hay waste differed among feeders (P < 0.001): Waste Less, 5%; Cinch Net, 6%; Hayhut, 9%; Covered Cradle, 11%; Tombstone Saver, 13%; Tombstone, Cone, and Ring, 19%; Hay Sleigh, 33%; and no-feeder control, 57%. Feeder design also affected payback (P < 0.01). The Cinch Net paid for itself in less than 1 mo; Tombstone and Ring, 2 mo; Hayhut and Tombstone Saver, 4 mo; Hay Sleigh, 5 mo; Waste Less, 8 mo; Cone, 9 mo; and Covered Cradle, 20 mo. Round-bale feeder design affected hay waste and payback, but not estimated hay intake or BW change during horse feeding.

  19. Three empirical essays on consumer behavior related to climate change and energy

    NASA Astrophysics Data System (ADS)

    Jacobsen, Grant Douglas

    This dissertation consists of three essays. All of the chapters address a topic in the area of household and consumer behavior related to climate change or energy. The first chapter is titled "The Al Gore Effect: An Inconvenient Truth and Voluntary Carbon Offsets". This chapter examines the relationship between climate change awareness and household behavior by testing whether Al Gore's documentary An Inconvenient Truth caused an increase in the purchase of voluntary carbon offsets. The analysis shows that in the two months following the film's release, zip codes within a 10-mile radius of a zip code where the film was shown experienced a 50 percent relative increase in the purchase of voluntary carbon offsets. The second chapter is titled "Are Building Codes Effective at Saving Energy? Evidence from Residential Billing Data in Florida". The analysis shows that Florida's energy-code change that took effect in 2002 is associated with a 4-percent decrease in electricity consumption and a 6-percent decrease in natural-gas consumption in Gainesville, FL. The estimated private payback period for the average residence is 6.4 years and the social payback period ranges between 3.5 and 5.3 years. The third chapter in this dissertation is titled "Do Environmental Offsets Increase Demand for Dirty Goods? Evidence from Residential Electricity Demand". This study evaluates the relationship between green products and existing patterns of consumer behavior by examining the relationship between household enrollment in a green electricity program and consumption of residential electricity. The results suggest there are two different types of green consumers. One type makes a small monthly donation and partially views the donation as a substitute for a previously existing pattern of green behavior, in this case, energy conservation. The other type makes a larger monthly donation and views the donation as a way to make strictly additional improvements in environmental quality.

  20. A field demonstration of energy conservation using occupancy sensor lighting control in equipment rooms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dagle, J.E.

    1992-09-01

    The Pacific Northwest Laboratory identified energy savings potential of automatic equipment-room lighting controls, which was demonstrated by the field experiment described in this report. Occupancy sensor applications have gained popularity in recent years due to improved technology that enhances reliability and reduces cost. Automatic lighting control using occupancy sensors has been accepted as an energy-conservation measure because it reduces wasted lighting. This study focused on lighting control for equipment rooms, which have inherent conditions ideal for automatic lighting control, i.e., an area which is seldom occupied, multiple users of the area who would not know if others are in themore » room when they leave, and high lighting energy intensity in the area. Two rooms were selected for this study: a small equipment room in the basement of the 337 Building, and a large equipment area in the upper level of the 329 Building. The rooms were selected to demonstrate the various degrees of complexity which may be encountered in equipment rooms throughout the Hanford Site. The 337 Building equipment-room test case demonstrated a 97% reduction in lighting energy consumption, with an annual energy savings of $184. Including lamp-replacement savings, a total savings of $306 per year is offset by an initial installation cost of $1,100. The installation demonstrates a positive net present value of $2,858 when the lamp-replacement costs are included in a life-cycle analysis. This also corresponds to a 4.0-year payback period. The 329 Building equipment-room installation resulted in a 92% reduction in lighting energy consumption. This corresponds to annual energy savings of $1,372, and a total annual savings of $2,104 per year including lamp-replacement savings. The life-cycle cost analysis shows a net present value of $15,855, with a 5.8-year payback period.« less

  1. Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

    2008-11-11

    This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct ofmore » the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.« less

  2. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  3. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  4. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  5. 20 CFR 655.310 - Attestations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... school, and the course of study shall be one accredited by a State Board of Nursing (or its equivalent... 4-year college, or a diploma school. See § 655.350(b) of this part. Financing by the facility... or pay-back programs) to such persons. (ii) Unreasonableness of second step. The steps described in...

  6. 20 CFR 655.310 - Attestations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... school, and the course of study shall be one accredited by a State Board of Nursing (or its equivalent... 4-year college, or a diploma school. See § 655.350(b) of this part. Financing by the facility... or pay-back programs) to such persons. (ii) Unreasonableness of second step. The steps described in...

  7. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  8. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... building energy or water system with an energy or water conservation measure by retrofit to an existing... estimated payback time is significantly less than the useful life of that system, and of the Federal...

  9. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... building energy or water system with an energy or water conservation measure by retrofit to an existing... estimated payback time is significantly less than the useful life of that system, and of the Federal...

  10. Fast Payback

    ERIC Educational Resources Information Center

    Simon, David

    2008-01-01

    Energy costs are projected to rise as much as 12 percent in 2008, and a facility's "carbon footprint" has become an issue of increasing importance. So, many schools and universities are taking a hard look at their energy consumption. Education facilities can save tens of thousands of dollars in yearly electric costs, and cut harmful emissions by…

  11. Modeling Stochastic Energy and Water Consumption to Manage Residential Water Uses

    NASA Astrophysics Data System (ADS)

    Abdallah, A. M.; Rosenberg, D. E.; Water; Energy Conservation

    2011-12-01

    Water energy linkages have received growing attention from the water and energy utilities as utilities recognize that collaborative efforts can implement more effective conservation and efficiency improvement programs at lower cost with less effort. To date, limited energy-water household data has allowed only deterministic analysis for average, representative households and required coarse assumptions - like the water heater (the primary energy use in a home apart from heating and cooling) be a single end use. Here, we use recent available disaggregated hot and cold water household end-use data to estimate water and energy consumption for toilet, shower, faucet, dishwasher, laundry machine, leaks, and other household uses and savings from appliance retrofits. The disaggregated hot water and bulk water end-use data was previously collected by the USEPA for 96 single family households in Seattle WA and Oakland CA, and Tampa FL between the period from 2000 and 2003 for two weeks before and four weeks after each household was retrofitted with water efficient appliances. Using the disaggregated data, we developed a stochastic model that represents factors that influence water use for each appliance: behavioral (use frequency and duration), demographical (household size), and technological (use volume or flowrate). We also include stochastic factors that govern energy to heat hot water: hot water fraction (percentage of hot water volume to total water volume used in a certain end-use event), heater water intake and dispense temperatures, and energy source for the heater (gas, electric, etc). From the empirical household end-use data, we derive stochastic probability distributions for each water and energy factor where each distribution represents the range and likelihood of values that the factor may take. The uncertainty of the stochastic water and energy factors is propagated using Monte Carlo simulations to calculate the composite probability distribution for water and energy use, potential savings, and payback periods to install efficient water end-use appliances and fixtures. Stochastic model results show the distributions among households for (i) water end-use, (ii) energy consumed to use water, and (iii) financial payback periods. Compared to deterministic analysis, stochastic modeling results show that hot water fractions for appliances follow normal distributions with high standard deviation and reveal pronounced variations among households that significantly affect energy savings and payback period estimates. These distributions provide an important tool to select and size water conservation programs to simultaneously meet both water and energy conservation goals. They also provide a way to identify and target a small fraction of customers with potential to save large water volumes and energy from appliance retrofits. Future work will embed this household scale stochastic model in city-scale models to identify win-win water management opportunities where households save money by conserving water and energy while cities avoid costs, downsize, or delay infrastructure development.

  12. Energy conservation for housing: A workbook

    NASA Astrophysics Data System (ADS)

    1982-05-01

    Multifamily housing project managers can reduce their energy costs from 30 to 60 percent by capitalizing on a variety of energy conservation opportunities (ECO's) identified in HUD research on the physical condition of public housing stock. This workbook prepares managers for this planning and for making individualized energy audits. It provides all the materials they need to proceed, including analysis sheets for calculating costs - benefit and payback periods for each of the 50 ECO's described. The ECO's listed all into four general categories: architectural improvements to the energy design of the building envelope; heating system ECO's to increase energy efficiency; secondary ECO's related to the domestic water supply, air conditioning systems, and central laundry equipment; and electric system ECO's reducing utility surcharges and increasing light bulb efficiency.

  13. Comparative environmental and economic analysis of conventional and nanofluid solar hot water technologies.

    PubMed

    Otanicar, Todd P; Golden, Jay S

    2009-08-01

    This study compares environmental and economic impacts of using nanofluids to enhance solar collector efficiency as compared to conventional solar collectors for domestic hotwater systems. Results show that for the current cost of nanoparticles the nanofluid based solar collector has a slightly longer payback period but at the end of its useful life has the same economic savings as a conventional solar collector. The nanofluid based collector has a lower embodied energy (approximately 9%) and approximately 3% higher levels of pollution offsets than a conventional collector. In addition if 50% penetration of residential nanofluid based solar collector systems for hot water heating could be achieved in Phoenix, Arizona over 1 million metric tons of CO2 would be offset per year.

  14. Cost-benefit analysis and emission reduction of energy efficient lighting at the Universiti Tenaga Nasional.

    PubMed

    Ganandran, G S B; Mahlia, T M I; Ong, Hwai Chyuan; Rismanchi, B; Chong, W T

    2014-01-01

    This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.

  15. Cost-Benefit Analysis and Emission Reduction of Energy Efficient Lighting at the Universiti Tenaga Nasional

    PubMed Central

    Ganandran, G. S. B.; Mahlia, T. M. I.; Ong, Hwai Chyuan; Rismanchi, B.; Chong, W. T.

    2014-01-01

    This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment. PMID:25133258

  16. Life cycle assessment of biomethane use in Argentina.

    PubMed

    Morero, Betzabet; Groppelli, Eduardo; Campanella, Enrique A

    2015-04-01

    Renewable substitutes for natural gas, such as biogas, require adequate treatment to remove impurities. This paper presents the life cycle and environmental impact of upgrading biogas using absorption-desorption process with three different solvents: water, diglycolamine and polyethylene glycol dimethyl ether. The results showed that water produces a minor impact in most of the considered categories, and an economic analysis showed that water is the most feasible solvent for obtaining the lowest payback period. This analysis includes three different sources for biogas production and two end uses for biomethane. The use of different wastes as sources results in different environmental impacts depending on the type of energy used in the anaerobic digestion. The same situation occurs when considering the use of biomethane as a domestic fuel or for power generation. Using energy from biogas to replace conventional energy sources in production and upgrading biogas significantly reduce the environmental impacts of processes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Sustainable Skyscrapers: Designing the Net Zero Energy Building of the Future

    NASA Astrophysics Data System (ADS)

    Kothari, S.; Bartsch, A.

    2016-12-01

    Cities of the future will need to increase population density in order to keep up with the rising populations in the limited available land area. In order to provide sufficient power as the population grows, cities must become more energy efficient. Fossil fuels and grid energy will continue to become more expensive as nonrenewable resources deplete. The obvious solution to increase population density while decreasing the reliance on fossil fuels is to build taller skyscrapers that are energy neutral, i.e. self-sustaining. However, current skyscrapers are not energy efficient, and therefore cannot provide a sustainable solution to the problem of increasing population density in the face of depleting energy resources. The design of a net zero energy building that includes both residential and commercial space is presented. Alternative energy systems such as wind turbines, photovoltaic cells, and a waste-to-fuel conversion plant have been incorporated into the design of a 50 story skyscraper that is not reliant on fossil fuels and has a payback time of about six years. Although the current building was designed to be located in San Francisco, simple modifications to the design would allow this building to fit the needs of any city around the world.

  18. Water Management Planning: A Case Study at Blue Grass Army Depot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solana, Amy E.; Mcmordie, Katherine

    2006-04-03

    Executive Order 13123, Greening the Government Through Efficient Energy Management, mandates an aggressive policy for reducing potable water consumption at federal facilities. Implementation guid¬ance from the U.S. Department of Energy (DOE) set a requirement for each federal agency to “reduce potable water usage by implementing life cycle, cost-effective water efficiency programs that include a water management plan, and not less than four Federal Energy Management Program (FEMP) Best Manage¬ment Practices (BMPs).” The objective of this plan is to gain full compliance with Executive Order 13123 and associated DOE implementation guidance on behalf of Blue Grass Army Depot (BGAD), Richmond, Kentucky.more » In accordance with this plan, BGAD must: • Incorporate the plan as a component of the Installation energy conservation plan • Investigate the water savings potential and life-cycle cost effectiveness of the Operations and Maintenance (O&M) and retrofit/replacement options associated with the ten FEMP BMPs • Put into practice all applicable O&M options • Identify retrofit/replacement options appropriate for implementation (based upon calculation of the simple payback periods) • Establish a schedule for implementation of applicable and cost-effective retrofit/replacement options.« less

  19. High-Efficiency Housing at the Fort Peck Indian Reservation: Opportunities and Lessons Learned

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lisell, Lars J; Desai, Jal D; Dean, Jesse D

    This project was initiated to provide design assistance in an effort to maximize energy performance for affordable housing at the Fort Peck Indian Reservation near Poplar, Montana. The Make It Right Foundation (MIRF) built 20 high performing homes (LEED Platinum) in 2015 and 2016 with three (3) different design options. NREL and EPA set out to provide energy analysis along with measurement and verification (M and V) of the homes to characterize energy use and provide clarity for future decision making with regard to tribal housing options. The results included herein summarize the energy end uses and documents projected energymore » impacts from various aspects of the MIRF home designs and construction. This report includes an analysis of energy use in 5 MIRF homes, comparing energy use across the different styles and configurations. Energy models were created for the 2 styles of MIRF homes, including renewable energy assessment for photovoltaic (PV) systems. Existing tribal housing has also been analyzed, with 5 housing units being analyzed for energy use and an energy model being created for 1 housing unit. The findings of this study highlight many of the challenges that arise when attempting to construct high performance housing in a region where such construction practices are still relatively rare. Homes in Poplar are well designed and, for the most part, and include climate specific design considerations appropriate for northeastern Montana. The most significant issues identified in MIRF homes were related to the work done to put the homes on the foundation, insulate the crawlspaces, and do final connection with the utilities. The Taxed II Credit homes are well designed and well suited to northeastern Montana, and with slight modifications to the design and construction could be very efficient. All occupant comfort and energy usage issues that were identified during the site visits can be remedied through retrofit measures that are relatively inexpensive. Energy efficiency opportunities were found that can be implemented in each of the homes. These retrofits are generally inexpensive and have a quick return on investment. While the MIRF houses as well as the Taxed II Credit homes can achieve high levels of energy performance with modest retrofits. Similar houses built in the future could achieve even better performance with minor design changes, and generally low incremental cost. Renewable energy systems are economically feasible in this area, but the payback is on the high side of what would likely be acceptable to homeowners. If the price of solar comes down to $2/watt installed, the systems will achieve a simple payback of 13 years, which is likely a return on investment that is attractive to homeowners. If the homes are made sufficiently tight to be high performance, energy recovery ventilators will be necessary to maintain acceptable indoor air quality. The Taxed II Credit homes are already equipped with heat recovery ventilators (HRVs), and they seem to function well. As PV prices continue to decline, start implementing projects as they become cost effective.« less

  20. Spatially-explicit estimates of greenhouse-gas payback times for perennial cellulosic biomass production on open lands in the Lake States

    NASA Astrophysics Data System (ADS)

    Sahajpal, R.

    2015-12-01

    The development of renewable energy sources is an integral step towards mitigating the carbon dioxide induced component of climate change. One important renewable source is plant biomass, comprising both food crops such as corn (Zea mays) and cellulosic biomass from short-rotation woody crops (SRWC) such as hybrid-poplar (Populus spp.) and Willow (Salix spp.). Due to their market acceptability and excellent energy balance, cellulosic feedstocks represent an abundant and if managed properly, a carbon-neutral and environmentally beneficial resource. We evaluate how site variability impacts the greenhouse-gas (GHG) benefits of SRWC plantations on lands potentially suited for bioenergy feedstock production in the Lake States (Minnesota, Wisconsin, Michigan). We combine high-resolution, spatially-explicit estimates of biomass, soil organic carbon and nitrous oxide emissions for SRWC plantations from the Environmental Policy Integrated Climate (EPIC) model along with life cycle analysis results from the GREET model to determine the greenhouse-gas payback time (GPBT) or the time needed before the GHG savings due to displacement of fossil fuels exceeds the initial losses from plantation establishment. We calibrate our models using unique yield and N2O emission data from sites across the Lake states that have been converted from pasture and hayfields to SRWC plantations. Our results show a reduction of 800,000 ha in non-agricultural open land availability for biomass production, a loss of nearly 37% (see attached figure). Overall, GPBTs range between 1 and 38 years, with the longest GPBTs occurring in the northern Lake states. Initial soil nitrate levels and site drainage potential explain more than half of the variation in GPBTs. Our results indicate a rapidly closing window of opportunity to establish a sustainable cellulosic feedstock economy in the Lake States.

  1. Technical-financial evaluation of rainwater harvesting systems in commercial buildings-case ase studies from Sonae Sierra in Portugal and Brazil.

    PubMed

    Sousa, Vitor; Silva, Cristina Matos; Meireles, Inês C

    2017-11-10

    Water is an essential and increasingly scarce resource that should be preserved. The evolution of the human population and communities has contributed to the global decrease of potable water availability and the reduction of its consumption is now compulsory. Rainwater harvesting systems (RWHS) are emerging as a viable alternative source for water consumption in non-potable uses. The present study aims to contribute to the promotion of water efficiency, focusing on the application of rainwater harvesting systems in commercial buildings, and comprises four stages: (i) development of a technical evaluation tool to aid the design of RWHS and support their financial evaluation; (ii) validation of the tool using operational data from an existing RWHS installed at Colombo Shopping Center, in Lisbon, Portugal; (iii) assessment of the sensibility of the technical evaluation tool results to the variation of the inputs, namely the precipitation and consumption, through a parametric analysis for the Colombo Shopping Center; and (iv) comparison of the performance and financial feasibility of hypothetical RWHS in two existing commercial buildings. The technical tool was applied to two Sonae Sierra's shopping centers, one in Portugal and one in Brazil. The installation of a 200-m 3 tank is advised for the first case study, allowing non-potable water savings of 60% but a payback period of about 19 years. In the Brazilian shopping, the implementation of a tank with a capacity ranging from 100 to 400 m 3 leads to non-potable savings between 20 and 50%, but with smaller payback period, under 2 years, due to the relatively lower investment costs and higher water fees.

  2. DEEP: Database of Energy Efficiency Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Tianzhen; Piette, Mary; Lee, Sang Hoon

    A database of energy efficiency performance (DEEP) is a presimulated database to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 10 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER [sic] prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones.more » DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air conditioning, plug loads, and domestic hot war. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center (NERSC) of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of the CEC PIER project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users' decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit.« less

  3. A model for estimating the impact of changes in children's vaccines.

    PubMed

    Simpson, K N; Biddle, A K; Rabinovich, N R

    1995-12-01

    To assist in strategic planning for the improvement of vaccines and vaccine programs, an economic model was developed and tested that estimates the potential impact of vaccine innovations on health outcomes and costs associated with vaccination and illness. A multistep, iterative process of data extraction/integration was used to develop the model and the scenarios. Parameter replication, sensitivity analysis, and expert review were used to validate the model. The greatest impact on the improvement of health is expected to result from the production of less reactogenic vaccines that require fewer inoculations for immunity. The greatest economic impact is predicted from improvements that decrease the number of inoculations required. Scenario analysis may be useful for integrating health outcomes and economic data into decision making. For childhood infections, this analysis indicates that large cost savings can be achieved in the future if we can improve vaccine efficacy so that the number of required inoculations is reduced. Such an improvement represents a large potential "payback" for the United States and might benefit other countries.

  4. SOLFEAS: An Interactive Program for Estimating the Economic Feasibility of an Active Solar Thermal Energy System.

    DTIC Science & Technology

    1983-01-01

    SOt MET State city Station Number HAWAII Barbers Point 22514 Hilo 21504 Honolulu 22521 Lihue 22536 IDAHO Boise 24131 Lewiston 24149 Pocatello 24156...Hawaii 10 Washington, Oregon, Idaho , Alaska SOLFEAS treats the impact of these published fuel costs and escalation rates on the system payback as

  5. Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting at T.J.Maxx in Manchester, NH Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myer, Michael; Goettel, Russell T.

    2010-06-29

    A report describing the process and results of replacing existing parking lot lighting, looking at a LED option with occupancy sensors, and conventional alternates. Criteria include payback, light levels, occupant satisfaction. This report is Phase I of II. Phase I deals with initial installation.

  6. Payback Time? Discourses of Lack, Debt and the Moral Regulation of Teacher Education

    ERIC Educational Resources Information Center

    Beighton, Chris

    2016-01-01

    This paper analyses recent policy and discourse in the UK lifelong learning sector to identify a tension in discourse which positions teacher educators as essential to the knowledge economy while simultaneously insisting on the deficits they represent. Drawing on critical analyses from Friedrich Nietzsche, Maurizio Lazzarato and Gilles Deleuze, I…

  7. 78 FR 76759 - Magnuson-Stevens Fishery Conservation and Management Act Provisions; Fisheries of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... determination. This rule implements a system of AMs that would result in a payback if: (1) The stock is... catch target (ACT) setting process because it is ``flawed and produces highly inaccurate results,'' but... chronic overharvesting in the recreational fishery. NMFS does not have the legal authority to redistribute...

  8. 78 FR 36197 - Request for Public Comment: 60-Day Proposed Information Collection: Application for Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... Section 3506 (c)(2)(A) of the Paperwork Reduction Act of 1995 which requires 60-days advance opportunity... Management and Budget (OMB) for review. Proposed Collection: Title: 0917-0006, ``Application for... performance of recipients; and to place recipients at payback sites. The IHS Scholarship Program streamlined...

  9. 24 CFR 965.304 - Order of funding.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Order of funding. 965.304 Section....304 Order of funding. Within the funds available to a PHA, energy conservation measures should be accomplished with the shortest pay-back periods funded first. A PHA may make adjustments to this funding order...

  10. Techno-economical assessment of grid connected PV/T using nanoparticles and water as base-fluid systems in Malaysia

    NASA Astrophysics Data System (ADS)

    Al-Waeli, Ali H. A.; Kazem, Hussein A.; Sopian, K.; Chaichan, Miqdam T.

    2018-07-01

    In this study, the techno-economic assessment of GCPVT with nanofluid has been investigated based on theoretical and experimental work in Malaysia. The productivity and utilisation of the PV have been investigated using yield and capacity factors (CFs), respectively. Also, the cost of energy and payback period has been calculated. The system installed, tested, and data have been collected. Evaluation of the system in terms of current, voltage, power and efficiency are presented. The average daily ambient temperature and total global solar energy in Kuala Lumpur are 38.89°C and 4062 Wh/m2, respectively. MATLAB software is used to analyse the measured data. The assessment results show that the GCPVT system has annual yield factor, CF, the cost of energy; payback period, and efficiency are (128.34-183.75) kWh/kWp, (17.82-25.52)%, 0.196 USD/kWh, 7-8 years and 9.1%, respectively. This study indicates that the GCPVT system with nanofluid improved the PV technical and economic performance.

  11. Extraction of astaxanthin from microalgae: process design and economic feasibility study

    NASA Astrophysics Data System (ADS)

    Zgheib, Nancy; Saade, Roxana; Khallouf, Rindala; Takache, Hosni

    2018-03-01

    In this work, the process design and the economic feasibility of natural astaxanthin extraction fromHaematococcus pluvialisspecies have been reported. Complete process drawing of the process was first performed, and then the process was designed including five main steps being the harvesting process, the cell disruption, the spray drying, the supercritical CO2extraction and the anaerobic digestion. The major components of the facility would include sedimentation tanks, a disk stack centrifuge, a bed miller, a spray dryer, a multistage compressor, an extractor, a pasteurizer and a digester. All units have been sized assuming a 10 kg/h of dried biomass as a feedstock to produce nearly 2592 kg of astaxanthin per year. The investment payback time and the return on investment were all estimated for different market prices of astaxanthin. Based on the results the production process was found to become economically feasible for a market price higher than 1500/Kg. Also, a payback period of 1 year and an ROI equal to 113% was estimated for an astaxanthin market price equal to 6000/Kg.

  12. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phadke, Amol; Shah, Nihar; Abhyankar, Nikit

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robustmore » over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment« less

  13. A Comparison of Prediction Methods for Design of Pump as Turbine for Small Hydro Plant: Implemented Plant

    NASA Astrophysics Data System (ADS)

    Naeimi, Hossein; Nayebi Shahabi, Mina; Mohammadi, Sohrab

    2017-08-01

    In developing countries, small and micro hydropower plants are very effective source for electricity generation with energy pay-back time (EPBT) less than other conventional electricity generation systems. Using pump as turbine (PAT) is an attractive, significant and cost-effective alternative. Pump manufacturers do not normally provide the characteristic curves of their pumps working as turbines. Therefore, choosing an appropriate Pump to work as a turbine is essential in implementing the small-hydro plants. In this paper, in order to find the best fitting method to choose a PAT, the results of a small-hydro plant implemented on the by-pass of a Pressure Reducing Valve (PRV) in Urmia city in Iran are presented. Some of the prediction methods of Best Efficiency Point of PATs are derived. Then, the results of implemented project have been compared to the prediction methods results and the deviation of from measured data were considered and discussed and the best method that predicts the specifications of PAT more accurately determined. Finally, the energy pay-back time for the plant is calculated.

  14. Energetic-environmental-economic assessment of the biogas system with three utilization pathways: Combined heat and power, biomethane and fuel cell.

    PubMed

    Wu, Bin; Zhang, Xiangping; Shang, Dawei; Bao, Di; Zhang, Suojiang; Zheng, Tao

    2016-08-01

    A typical biogas system with three utilization pathways, i.e., biogas upgrading, biogas combined heat and power (CHP), biogas solid oxide fuel cells (SOFCs) were designed. It was assessed from the viewpoint of energy, environment and economy by using energy efficiency, green degree and net present value index respectively. The assessment considered the trade-off relationships among these indexes, which is more comprehensive than previous systematic evaluation work only included single or two of the pathway(s) by using one or two of the index(es). Assessment results indicated that biogas upgrading pathway has the highest systematic energy efficiency (46.5%) and shortest payback period (8.9year) with the green degree production is the lowest (9.29gd/day). While for biogas SOFC pathway, although the green degree production is the highest (21.77gd/day), the payback period is longer (14.5year) and the energy efficiency is 13.6% lower than the biogas upgrading pathway. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Payback time for soil carbon and sugar-cane ethanol

    NASA Astrophysics Data System (ADS)

    Mello, Francisco F. C.; Cerri, Carlos E. P.; Davies, Christian A.; Holbrook, N. Michele; Paustian, Keith; Maia, Stoécio M. F.; Galdos, Marcelo V.; Bernoux, Martial; Cerri, Carlos C.

    2014-07-01

    The effects of land-use change (LUC) on soil carbon (C) balance has to be taken into account in calculating the CO2 savings attributed to bioenergy crops. There have been few direct field measurements that quantify the effects of LUC on soil C for the most common land-use transitions into sugar cane in Brazil, the world's largest producer . We quantified the C balance for LUC as a net loss (carbon debt) or net gain (carbon credit) in soil C for sugar-cane expansion in Brazil. We sampled 135 field sites to 1 m depth, representing three major LUC scenarios. Our results demonstrate that soil C stocks decrease following LUC from native vegetation and pastures, and increase where cropland is converted to sugar cane. The payback time for the soil C debt was eight years for native vegetation and two to three years for pastures. With an increasing need for biofuels and the potential for Brazil to help meet global demand, our results will be invaluable for guiding expansion policies of sugar-cane production towards greater sustainability.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

    In August 2008 the Pacific Northwest National Laboratory (PNNL) conducted a light emitting diode (LED) residential lighting demonstration project for the U.S. Department of Energy (DOE), Office of Building Technologies, as part of DOE’s Solid State Lighting (SSL) Technology Demonstration Gateway Program. Two lighting technologies, an LED replacement for downlight lamps (bulbs) and an LED undercabinet lighting fixture, were tested in the demonstration which was conducted in two homes built for the 2008 Tour of Homes in Eugene, Oregon. The homes were built by the Lane County Home Builders Association (HBA), and Future B Homes. The Energy Trust of Oregonmore » (ETO) also participated in the demonstration project. The LED downlight product, the LR6, made by Cree LED Lighting Solutions acts as a screw-in replacement for incandescent and halogen bulbs in recessed can downlights. The second product tested is Phillips/Color Kinetics’ eW® Profile Powercore undercabinet fixture designed to mount under kitchen cabinets to illuminate the countertop and backsplash surfaces. Quantitative and qualitative measurements of light performance and electrical power usage were taken at each site before and after initially installed halogen and incandescent lamps were replaced with the LED products. Energy savings and simple paybacks were also calculated and builders who toured the homes were surveyed for their responses to the LED products. The LED downlight product drew 12 Watts of power, cutting energy use by 82% compared to the 65W incandescent lamp and by 84% compared to the 75W halogen lamp. The LED undercabinet fixture drew 10 watts, cutting energy use by 83% to 90% compared to the halogen product, which was tested at two power settings: a low power 60W setting and a high power 105W setting. The LED downlight consistently provided more light than the halogen and incandescent lamps in horizontal measurements at counter height and floor level. It also outperformed in vertical illuminance measurements taken on the walls, indicating better lateral dispersion of the light. The undercabinet fixture’s light output was midway between the low and high power halogen undercabinet fixture light outputs (35.8 foot candle versus 13.4 fc and 53.4 fc) but it produced a more uniform light (max/min ratio of 7.0 versus 10.8). The color correlated temperature (CCT, the blue or yellowness) of the LED light correlated well with the halogen and incandescent lights (2675 K vs 2700 K). The color rendering of the LED downlight also correlated well at 92 CRI compared to 100 CRI for the halogen and incandescent lamps. The LED undercabinet fixture had measures of 2880 K CCT and 71 CRI compared to the 2700 K and 100 CRI scores for the halogen undercabinet fixture. Builders who toured the homes were surveyed; they gave the LED downlight high marks for brightness, said the undercabinet improved shadows and glare and said both products improved overall visibility, home appearance, and home value. Paybacks on the LED downlight ranged from 7.6 years (assuming electricity cost of 11 c/kWh) to 13.5 years (at 5C/kWh). Paybacks on the LED undercabinet fixture in a new home ranged from 4.4 years (11c/kWh electricity) to 7.6 years (5c/kWh) based on product costs of $95 per LED downlight and $140 per LED undercabinet fixture at 3 hrs per day of usage for the downlight and 2 hrs per day for the undercabinet lighting.« less

  17. Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Im, Piljae; Liu, Xiaobing; Henderson, Jr., Hugh

    With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station Southmore » (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.« less

  18. Engineering Analysis and Economic Evaluation of the Synthesis of Composite CuO/ZnO/ZrO2 Nanocatalyst

    NASA Astrophysics Data System (ADS)

    Nandiyanto, A. B. D.; Hayati, W. R.; Aziz, T. A.; Ragadhita, R.; Abdullah, A. G.; Widiaty, I.

    2018-02-01

    The purpose of this study was to evaluate the synthesis process of composite CuO/ZnO/ZrO2 (CZZ) nanocatalyst. The CZZ nanocatalyst is used as a catalyst in the hydrogenation reaction, which is used to convert harmful CO2 gas into liquid fuels such as methanol. In this study, CZZ produced using the sol-gel autocombustion method was selected as a model of the production procedure. The evaluation was conducted into two factors: engineering and economic analysis. Engineering analysis was analyzed based on the available apparatuses and raw materials in online web. Then, these data were used and compared with the mass balance approximation. The economic analysis was done using several economic parameters, including such as gross margin, internal rate return, payback period, cumulative net value, break even point (BEP), profitability index on sales to investment. Engineering analysis showed the present method can be applied using available apparatuses and raw materials in market. Economic analysis result confirmed that the present project is profitable. The analysis concluded that the present project for the production of CZZ nanocatalyst is prospective in small scale industry and profitable (by positive values in all economic parameters).

  19. Alternative Fuels Data Center: Massachusetts Fleet Braun's Express

    Science.gov Websites

    economy by an estimated 1 mile per gallon (MPG) across Braun's 185 tractor fleet. This equates to 1,500 has collected, the APUs improve overall fuel economy from 5.87 MPG to 6.75 MPG and have a payback Aerodynamics Technologies that improve a vehicle's aerodynamics can provide significant fuel economy

  20. Solar power satellite. Concept evaluation. Activities report. Volume 2: Detailed report

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Comparative data are presented among various design approaches to thermal engine and photovoltaic SPS (Solar Power System) concepts, to provide criteria for selecting the most promising systems for more detailed definition. The major areas of the SPS system to be examined include solar cells, microwave power transmission, transportation, structure, rectenna, energy payback, resources, and environmental issues.

  1. Save Energy Now Assessment Helps Expand Energy Management Program at Shaw Industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Shaw Industries carpet manufacturing plant #20 in Dalton, Georgia, optimized boiler operation and installed waste heat exchangers on two processes in the dye house and an economizer on one boiler, for a payback of 1.7 years. These results prompted plant #4, also located in Dalton, to participate in an assessment.

  2. Choice Behavior of Nonpathological Women Playing Concurrently Available Slot Machines: Effect of Changes in Payback Percentages

    ERIC Educational Resources Information Center

    Weatherly, Jeffrey N.; Thompson, Bradley J.; Hodny, Marisa; Meier, Ellen

    2009-01-01

    In a simulated casino environment, 6 nonpathological women played concurrently available commercial slot machines programmed to pay out at different rates. Participants did not always demonstrate preferences for the higher paying machine. The data suggest that factors other than programmed or obtained rate of reinforcement may control gambling…

  3. Lessons Learned from the Private Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robichaud, Robert J

    This session is focused on lessons learned from private sector energy projects that could be applied to the federal sector. This presentation tees up the subsequent presentations by outlining the differences between private and federal sectors in objectives, metrics for determining success, funding resources/mechanisms, payback and ROI evaluation, risk tolerance/aversion, new technology adoption perspectives, and contracting mechanisms.

  4. 75 FR 20369 - Request for Public Comment: 30-Day Proposed Information Collection: Application for Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-19

    ... Act of 1995 which requires a 30-day advance opportunity for public comment on the proposed information collection project, the Indian Health Service (IHS) has submitted to the Office of Management and Budget (OMB... the academic performance of awardees, to place awardees at payback sites, and for awardees to request...

  5. Addressing Student Debt: A New Post Secondary Learning Support System

    ERIC Educational Resources Information Center

    Association of Canadian Community Colleges, 2001

    2001-01-01

    Access and affordability are bountiful concepts and key words used by policy makers in defining the role of post-secondary education and training in Canada. However, these words have not translated into action for many learners due to student debt. Incurred from high tuition fees, costly and complex payback schemes and under-funding, chronic…

  6. Successful industry-university graduate-level research partnerships at the Pennsylvania State University

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feltus, M.A.

    1996-12-31

    Previously, nuclear utilities have been considered {open_quotes}deep pockets{close_quotes} for university research; however, in the current cost-cutting competitive environment, most utilities have drastically reduced or eliminated research. Any collaboration with universities requires that any research effort have a focused objective, short-term duration, and tangible payback. Furthermore, the research must concentrate on solving operating problems, rather than on long-term general concerns. Although practical studies may seem mundane, untheoretical, and uninteresting for most academics, such pragmatic topics can provide interesting research for students and helpful results for the utilities. This paper provides examples of the author`s research funded by utilities. Each project hasmore » a specific objective involving a particular utility need or computer code analysis tool.« less

  7. What are the potential benefits of including latent storage in common wallboard?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, T.K.; Tomlinson, J.J.

    1992-07-01

    Previous work has shown that wallboard can be successfully manufactured to contain up to 30% phase change material (PCM), or wax, thus enabling this common building material to serve as a thermal energy storage device. This material was analyzed for passive solar applications and found to save energy with a reasonable pay-back time period. Further evaluations of the wallboard are reported in this paper. This analysis looks at potential applications of PCM wallboard as a load management device and as a comfort enhancer. Results show that the wallboard is ineffective in modifying the comfort level but can provide significant loadmore » management relief with no energy penalty. Modifications to typical heating and air-conditioning control strategies were necessary for successful load management.« less

  8. What are the potential benefits of including latent storage in common wallboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, T.K.; Tomlinson, J.J.

    1992-01-01

    Previous work has shown that wallboard can be successfully manufactured to contain up to 30% phase change material (PCM), or wax, thus enabling this common building material to serve as a thermal energy storage device. This material was analyzed for passive solar applications and found to save energy with a reasonable pay-back time period. Further evaluations of the wallboard are reported in this paper. This analysis looks at potential applications of PCM wallboard as a load management device and as a comfort enhancer. Results show that the wallboard is ineffective in modifying the comfort level but can provide significant loadmore » management relief with no energy penalty. Modifications to typical heating and air-conditioning control strategies were necessary for successful load management.« less

  9. The role of modelling in prioritising and planning clinical trials.

    PubMed

    Chilcott, J; Brennan, A; Booth, A; Karnon, J; Tappenden, P

    2003-01-01

    To identify the role of modelling in planning and prioritising trials. The review focuses on modelling methods used in the construction of disease models and on methods for their analysis and interpretation. Searches were initially developed in MEDLINE and then translated into other databases. Systematic reviews of the methodological and case study literature were undertaken. Search strategies focused on the intersection between three domains: modelling, health technology assessment and prioritisation. The review found that modelling can extend the validity of trials by: generalising from trial populations to specific target groups; generalising to other settings and countries; extrapolating trial outcomes to the longer term; linking intermediate outcome measures to final outcomes; extending analysis to the relevant comparators; adjusting for prognostic factors in trials; and synthesising research results. The review suggested that modelling may offer greatest benefits where the impact of a technology occurs over a long duration, where disease/technology characteristics are not observable, where there are long lead times in research, or for rapidly changing technologies. It was also found that modelling can inform the key parameters for research: sample size, trial duration and population characteristics. One-way, multi-way and threshold sensitivity analysis have been used in informing these aspects but are flawed. The payback approach has been piloted and while there have been weaknesses in its implementation, the approach does have potential. Expected value of information analysis is the only existing methodology that has been applied in practice and can address all these issues. The potential benefit of this methodology is that the value of research is directly related to its impact on technology commissioning decisions, and is demonstrated in real and absolute rather than relative terms; it assesses the technical efficiency of different types of research. Modelling is not a substitute for data collection. However, modelling can identify trial designs of low priority in informing health technology commissioning decisions. Good practice in undertaking and reporting economic modelling studies requires further dissemination and support, specifically in sensitivity analyses, model validation and the reporting of assumptions. Case studies of the payback approach using stochastic sensitivity analyses should be developed. Use of overall expected value of perfect information should be encouraged in modelling studies seeking to inform prioritisation and planning of health technology assessments. Research is required to assess if the potential benefits of value of information analysis can be realised in practice; on the definition of an adequate objective function; on methods for analysing computationally expensive models; and on methods for updating prior probability distributions.

  10. Gender Aspects of the Economic Payback of a Tuition-Charging Higher Education

    ERIC Educational Resources Information Center

    Baskakova, M. E.

    2004-01-01

    For many decades now the sphere of education in Russia has been considered to be among the most well off among other spheres of activity, from the standpoint of gender equality. One component of radical economic reforms in Russia in the 1990s was the transformation of education financing. During the reform years the number of students in higher…

  11. DRIVE: Drive-Cycle Rapid Investigation, Visualization, and Evaluation

    Science.gov Websites

    specialized statistical clustering methods. The duration of these representative drive cycles, which aim to , DRIVE can benefit a variety of users. For example: Fleet managers can use the tool to make educated investment decisions by determining, in advance, the payback period for a given technology. Vehicle

  12. The Canonical Robot Command Language (CRCL).

    PubMed

    Proctor, Frederick M; Balakirsky, Stephen B; Kootbally, Zeid; Kramer, Thomas R; Schlenoff, Craig I; Shackleford, William P

    2016-01-01

    Industrial robots can perform motion with sub-millimeter repeatability when programmed using the teach-and-playback method. While effective, this method requires significant up-front time, tying up the robot and a person during the teaching phase. Off-line programming can be used to generate robot programs, but the accuracy of this method is poor unless supplemented with good calibration to remove systematic errors, feed-forward models to anticipate robot response to loads, and sensing to compensate for unmodeled errors. These increase the complexity and up-front cost of the system, but the payback in the reduction of recurring teach programming time can be worth the effort. This payback especially benefits small-batch, short-turnaround applications typical of small-to-medium enterprises, who need the agility afforded by off-line application development to be competitive against low-cost manual labor. To fully benefit from this agile application tasking model, a common representation of tasks should be used that is understood by all of the resources required for the job: robots, tooling, sensors, and people. This paper describes an information model, the Canonical Robot Command Language (CRCL), which provides a high-level description of robot tasks and associated control and status information.

  13. Applications of thermal energy storage to process heat and waste heat recovery in the iron and steel industry

    NASA Technical Reports Server (NTRS)

    Katter, L. B.; Peterson, D. J.

    1978-01-01

    The system identified operates from the primary arc furnace evacuation system as a heat source. Energy from the fume stream is stored as sensible energy in a solid medium (packed bed). A steam-driven turbine is arranged to generate power for peak shaving. A parametric design approach is presented since the overall system design, at optimum payback is strongly dependent upon the nature of the electric pricing structure. The scope of the project was limited to consideration of available technology so that industry-wide application could be achieved by 1985. A search of the literature, coupled with interviews with representatives of major steel producers, served as the means whereby the techniques and technologies indicated for the specific site are extrapolated to the industry as a whole and to the 1985 time frame. The conclusion of the study is that by 1985, a national yearly savings of 1.9 million barrels of oil could be realized through recovery of waste heat from primary arc furnace fume gases on an industry-wide basis. Economic studies indicate that the proposed system has a plant payback time of approximately 5 years.

  14. 25th anniversary article: Rise to power--OPV-based solar parks.

    PubMed

    Krebs, Frederik C; Espinosa, Nieves; Hösel, Markus; Søndergaard, Roar R; Jørgensen, Mikkel

    2014-01-08

    A solar park based on polymer solar cells is described and analyzed with respect to performance, practicality, installation speed, and energy payback time. It is found that a high voltage installation where solar cells are all printed in series enables an installation rate in Watts installed per minute that far exceed any other PV technology in existence. The energy payback time for the practical installation of polymer solar cell foil on a wooden 250 square meter platform in its present form is 277 days when operated in Denmark and 180 days when operated in southern Spain. The installation and de-installation rate is above 100 m min⁻¹, which, with the present performance and web width, implies installation of >200 W min⁻¹. In comparison, this also exceeds the overall manufacturing speed of the polymer solar cell foil with a width of 305 mm which is currently 1 m min⁻¹ for complete encapsulated and tested foil. It is also significant that simultaneous installation and de-installation which enables efficient schemes for decommissioning and recycling is possible. It is highlighted where research efforts should most rationally be invested in order to make grid electricity from OPV a reality (and it is within reach).

  15. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Nihar; Abhyankar, Nikit; Park, Won Young

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report.more » The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.« less

  16. The Canonical Robot Command Language (CRCL)

    PubMed Central

    Proctor, Frederick M.; Balakirsky, Stephen B.; Kootbally, Zeid; Kramer, Thomas R.; Schlenoff, Craig I.; Shackleford, William P.

    2017-01-01

    Industrial robots can perform motion with sub-millimeter repeatability when programmed using the teach-and-playback method. While effective, this method requires significant up-front time, tying up the robot and a person during the teaching phase. Off-line programming can be used to generate robot programs, but the accuracy of this method is poor unless supplemented with good calibration to remove systematic errors, feed-forward models to anticipate robot response to loads, and sensing to compensate for unmodeled errors. These increase the complexity and up-front cost of the system, but the payback in the reduction of recurring teach programming time can be worth the effort. This payback especially benefits small-batch, short-turnaround applications typical of small-to-medium enterprises, who need the agility afforded by off-line application development to be competitive against low-cost manual labor. To fully benefit from this agile application tasking model, a common representation of tasks should be used that is understood by all of the resources required for the job: robots, tooling, sensors, and people. This paper describes an information model, the Canonical Robot Command Language (CRCL), which provides a high-level description of robot tasks and associated control and status information. PMID:28529393

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, weremore » achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.« less

  18. Conducting retrospective impact analysis to inform a medical research charity’s funding strategies: the case of Asthma UK

    PubMed Central

    2013-01-01

    Background Debate is intensifying about how to assess the full range of impacts from medical research. Complexity increases when assessing the diverse funding streams of funders such as Asthma UK, a charitable patient organisation supporting medical research to benefit people with asthma. This paper aims to describe the various impacts identified from a range of Asthma UK research, and explore how Asthma UK utilised the characteristics of successful funding approaches to inform future research strategies. Methods We adapted the Payback Framework, using it both in a survey and to help structure interviews, documentary analysis, and case studies. We sent surveys to 153 lead researchers of projects, plus 10 past research fellows, and also conducted 14 detailed case studies. These covered nine projects and two fellowships, in addition to the innovative case studies on the professorial chairs (funded since 1988) and the MRC-Asthma UK Centre in Allergic Mechanisms of Asthma (the ‘Centre’) which together facilitated a comprehensive analysis of the whole funding portfolio. We organised each case study to capture whatever academic and wider societal impacts (or payback) might have arisen given the diverse timescales, size of funding involved, and extent to which Asthma UK funding contributed to the impacts. Results Projects recorded an average of four peer-reviewed journal articles. Together the chairs reported over 500 papers. All streams of funding attracted follow-on funding. Each of the various categories of societal impacts arose from only a minority of individual projects and fellowships. Some of the research portfolio is influencing asthma-related clinical guidelines, and some contributing to product development. The latter includes potentially major breakthroughs in asthma therapies (in immunotherapy, and new inhaled drugs) trialled by university spin-out companies. Such research-informed guidelines and medicines can, in turn, contribute to health improvements. The role of the chairs and the pioneering collaborative Centre is shown as being particularly important. Conclusions We systematically demonstrate that all types of Asthma UK’s research funding assessed are making impacts at different levels, but the main societal impacts from projects and fellowships come from a minority of those funded. Asthma UK used the study’s findings, especially in relation to the Centre, to inform research funding strategies to promote the achievement of impact. PMID:23651523

  19. Feed-in tariff structure development for photovoltaic electricity and the associated benefits for the Kingdom of Bahrain

    NASA Astrophysics Data System (ADS)

    Haji, Shaker; Durazi, Amal; Al-Alawi, Yaser

    2018-05-01

    In this study, the feed-in tariff (FIT) scheme was considered to facilitate an effective introduction of renewable energy in the Kingdom of Bahrain. An economic model was developed for the estimation of feasible FIT rates for photovoltaic (PV) electricity on a residential scale. The calculations of FIT rates were based mainly on the local solar radiation, the cost of a grid-connected PV system, the operation and maintenance cost, and the provided financial support. The net present value and internal rate of return methods were selected for model evaluation with the guide of simple payback period to determine the cost of energy and feasible FIT rates under several scenarios involving different capital rebate percentages, loan down payment percentages, and PV system costs. Moreover, to capitalise on the FIT benefits, its impact on the stakeholders beyond the households was investigated in terms of natural gas savings, emissions cutback, job creation, and PV-electricity contribution towards the energy demand growth. The study recommended the introduction of the FIT scheme in the Kingdom of Bahrain due to its considerable benefits through a setup where each household would purchase the PV system through a loan, with the government and the electricity customers sharing the FIT cost.

  20. Geothermal Heat Pump System for New Student Housing Project at the University at Albany Main Campus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lnu, Indumathi

    University at Albany successfully designed, constructed and is operating a new student housing building that utilizes ground source heat pump (GSHP) for heating and cooling the entire 191,500SF building. The installed system consists of a well field with 150 bores, 450 feet deep and (189) terminal heat pump units for a total capacity of 358 Tons cooling and 4,300 MBtu/h heating. The building opened in Fall 2012. The annual energy use and cost intensity of the building, after the changes made during the first 2 years’ of operation is 57kBtu/SF/Year and $1.30/SF/Year respectively. This is approximately 50% lower than themore » other residential quads on campus, despite the fact that the quads are not air-conditioned. The total project cost from design through 3-years of operations is approximately $6 Million, out of which $5.7 Million is for construction of the GSHP system including the well field. The University received a $2.78 Million grant from the Department of Energy. The estimated utility cost savings, compared to a baseline building with conventional HVAC system, is approximately $185,000. The estimated simple payback, after grant incentives, is 15 years. Additionally, the project has created 8.5FTE equivalent jobs.« less

  1. Machine learning-based screening of complex molecules for polymer solar cells

    NASA Astrophysics Data System (ADS)

    Jørgensen, Peter Bjørn; Mesta, Murat; Shil, Suranjan; García Lastra, Juan Maria; Jacobsen, Karsten Wedel; Thygesen, Kristian Sommer; Schmidt, Mikkel N.

    2018-06-01

    Polymer solar cells admit numerous potential advantages including low energy payback time and scalable high-speed manufacturing, but the power conversion efficiency is currently lower than for their inorganic counterparts. In a Phenyl-C_61-Butyric-Acid-Methyl-Ester (PCBM)-based blended polymer solar cell, the optical gap of the polymer and the energetic alignment of the lowest unoccupied molecular orbital (LUMO) of the polymer and the PCBM are crucial for the device efficiency. Searching for new and better materials for polymer solar cells is a computationally costly affair using density functional theory (DFT) calculations. In this work, we propose a screening procedure using a simple string representation for a promising class of donor-acceptor polymers in conjunction with a grammar variational autoencoder. The model is trained on a dataset of 3989 monomers obtained from DFT calculations and is able to predict LUMO and the lowest optical transition energy for unseen molecules with mean absolute errors of 43 and 74 meV, respectively, without knowledge of the atomic positions. We demonstrate the merit of the model for generating new molecules with the desired LUMO and optical gap energies which increases the chance of finding suitable polymers by more than a factor of five in comparison to the randomised search used in gathering the training set.

  2. A Comparison of Tissue Spray and Lipid Extract Direct Injection Electrospray Ionization Mass Spectrometry for the Differentiation of Eutopic and Ectopic Endometrial Tissues

    NASA Astrophysics Data System (ADS)

    Chagovets, Vitaliy; Wang, Zhihao; Kononikhin, Alexey; Starodubtseva, Natalia; Borisova, Anna; Salimova, Dinara; Popov, Igor; Kozachenko, Andrey; Chingin, Konstantin; Chen, Huanwen; Frankevich, Vladimir; Adamyan, Leila; Sukhikh, Gennady

    2018-02-01

    Recent research revealed that tissue spray mass spectrometry enables rapid molecular profiling of biological tissues, which is of great importance for the search of disease biomarkers as well as for online surgery control. However, the payback for the high speed of analysis in tissue spray analysis is the generally lower chemical sensitivity compared with the traditional approach based on the offline chemical extraction and electrospray ionization mass spectrometry detection. In this study, high resolution mass spectrometry analysis of endometrium tissues of different localizations obtained using direct tissue spray mass spectrometry in positive ion mode is compared with the results of electrospray ionization analysis of lipid extracts. Identified features in both cases belong to three lipid classes: phosphatidylcholines, phosphoethanolamines, and sphingomyelins. Lipids coverage is validated by hydrophilic interaction liquid chromatography with mass spectrometry of lipid extracts. Multivariate analysis of data from both methods reveals satisfactory differentiation of eutopic and ectopic endometrium tissues. Overall, our results indicate that the chemical information provided by tissue spray ionization is sufficient to allow differentiation of endometrial tissues by localization with similar reliability but higher speed than in the traditional approach relying on offline extraction.

  3. Is a Clean Development Mechanism project economically justified? Case study of an International Carbon Sequestration Project in Iran.

    PubMed

    Katircioglu, Salih; Dalir, Sara; Olya, Hossein G

    2016-01-01

    The present study evaluates a carbon sequestration project for the three plant species in arid and semiarid regions of Iran. Results show that Haloxylon performed appropriately in the carbon sequestration process during the 6 years of the International Carbon Sequestration Project (ICSP). In addition to a high degree of carbon dioxide sequestration, Haloxylon shows high compatibility with severe environmental conditions and low maintenance costs. Financial and economic analysis demonstrated that the ICSP was justified from an economic perspective. The financial assessment showed that net present value (NPV) (US$1,098,022.70), internal rate of return (IRR) (21.53%), and payback period (6 years) were in an acceptable range. The results of the economic analysis suggested an NPV of US$4,407,805.15 and an IRR of 50.63%. Therefore, results of this study suggest that there are sufficient incentives for investors to participate in such kind of Clean Development Mechanism (CDM) projects.

  4. Efficiency of overhead ceiling lifts in reducing musculoskeletal injury among carers working in long-term care institutions.

    PubMed

    Alamgir, Hasanat; Yu, Shicheng; Fast, Catherine; Hennessy, Stephanie; Kidd, Catherine; Yassi, Annalee

    2008-05-01

    A longitudinal study was conducted in three long-term care facilities to evaluate the effectiveness and cost benefit of overhead lifts in reducing the risk of musculoskeletal injury among healthcare workers. Analysis of injury trends spanning 6 years before intervention (1996-2001) and 4 years after intervention (2002-2005) found a significant and sustained decrease in workers' compensation claims per number of beds and in working days lost per bed. The payback period was estimated under various assumptions and varied from 6.3 to 6.2 years if only direct claim-cost savings were included, and from 2.06 to 3.20 years when indirect savings were added. The significant reductions in injury rates and compensation claims support intervention with overhead ceiling lifts. A more comprehensive evaluation of such programmes should incorporate in the analysis important variables such as staffing ratios, job stresses, injury reporting systems and compensation policies during the study period.

  5. Solar energy system economic evaluation. Final report for SEECO Lincoln, Lincoln, Nebraska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-09-01

    The economic analysis of the solar energy system that was installed at Lincoln, Nebraska is developed for this and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f-chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings and year of payback formore » the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Although budget constraints preclude an economic reevaluation of each of the sites, a similar site, Carlsbad, New Nexico, was done. When 1985 escalated values for fuel, costs, mass production, and improved design and installation techniques were applied, a significantly higher degree of savings was realized.« less

  6. Mass flow and energy balance plus economic analysis of a full-scale biogas plant in the rice-wine-pig system.

    PubMed

    Li, Jiang; Kong, Chuixue; Duan, Qiwu; Luo, Tao; Mei, Zili; Lei, Yunhui

    2015-10-01

    This paper presents mass flow and energy balance as well as an economic analysis for a biogas plant in a rice-wine-pig system at a practical rather than laboratory scale. Results showed feeding amount was 65.30 t d(-1) (total solid matter (TSM) 1.3%) for the normal temperature continuous stirred tank reactor (CSTR), and 16.20 t d(-1) (TSM 8.4%) for the mesophilic CSTR. The digestion produced 80.50 t d(-1) of mass, with 76.41 t d(-1) flowing into rice fields and 4.49 t d(-1) into composting. Energy consumption of this plant fluctuated with seasons, and surplus energy was 823, 221 kWh/year. Thus, biogas plant was critical for material recycling and energy transformation of this agro-ecosystem. The economic analysis showed that the payback time of the plant was 10.9 years. It also revealed application of biogas as a conventional energy replacement would be attractive for a crop-wine-livestock ecosystem with anaerobic digestion of manure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Techno-Economic Analysis of Solar Water Heating Systems inTurkey.

    PubMed

    Ertekin, Can; Kulcu, Recep; Evrendilek, Fatih

    2008-02-25

    In this study, solar water heater was investigated using meteorological and geographical data of 129 sites over Turkey. Three different collector types were compared in terms of absorber material (copper, galvanized sheet and selective absorber). Energy requirement for water heating, collector performances, and economical indicators were calculated with formulations using observed data. Results showed that selective absorbers were most appropriate in terms of coverage rate of energy requirement for water-heating all over Turkey. The prices of selective, copper and galvanized absorber type's heating systems in Turkey were 740.49, 615.69 and 490.89 USD, respectively. While payback periods (PBPs) of the galvanized absorber were lower, net present values (NPVs) of the selective absorber were higher than the rest. Copper absorber type collectors did not appear to be appropriate based on economical indicators.

  8. Techno-Economic Analysis of Solar Water Heating Systems in Turkey

    PubMed Central

    Ertekin, Can; Kulcu, Recep; Evrendilek, Fatih

    2008-01-01

    In this study, solar water heater was investigated using meteorological and geographical data of 129 sites over Turkey. Three different collector types were compared in terms of absorber material (copper, galvanized sheet and selective absorber). Energy requirement for water heating, collector performances, and economical indicators were calculated with formulations using observed data. Results showed that selective absorbers were most appropriate in terms of coverage rate of energy requirement for water-heating all over Turkey. The prices of selective, copper and galvanized absorber type's heating systems in Turkey were 740.49, 615.69 and 490.89 USD, respectively. While payback periods (PBPs) of the galvanized absorber were lower, net present values (NPVs) of the selective absorber were higher than the rest. Copper absorber type collectors did not appear to be appropriate based on economical indicators. PMID:27879764

  9. Energy efficiency and economic analysis of the thermomodernization of forest lodges in the Świętokrzyski National Park

    NASA Astrophysics Data System (ADS)

    Wciślik, Sylwia

    This paper analyses energy efficiency of thermomodernization project on the example of three forest lodges located in the Świętokrzyski National Park. Currently, one of the basic requirements posed for the buildings subjected to modernization is to reduce carbon dioxide emissions even above 80% in comparison with the original values. In order to fulfil such criteria, it is necessary to apply alternative solutions based on renewable energy sources. Due to limited budget, low cubic capacity and location of the buildings, solar collectors with storage tanks and biomass boilers provide a rational option. For such a case, the emissions of basic pollutants such as CO2, SOx, NOx or particulates is obtained. The study also gives the results of calculations of payback time (SPBT) for the investment for exemplary forest lodge.

  10. Energy information systems (EIS): Technology costs, benefit, and best practice uses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granderson, Jessica; Lin, Guanjing; Piette, Mary Ann

    2013-11-26

    Energy information systems are the web-based software, data acquisition hardware, and communication systems used to store, analyze, and display building energy data. They often include analysis methods such as baselining, benchmarking, load profiling, and energy anomaly detection. This report documents a large-scale assessment of energy information system (EIS) uses, costs, and energy benefits, based on a series of focused case study investigations that are synthesized into generalizable findings. The overall objective is to provide organizational decision makers with the information they need to make informed choices as to whether or not to invest in an EIS--a promising technology that canmore » enable up to 20 percent site energy savings, quick payback, and persistent low-energy performance when implemented as part of best-practice energy management programs.« less

  11. What are the potential benefits of including latent storage in common wallboard?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, T.K.; Tomlinson, J.J.

    1995-11-01

    Previous work has shown that wallboard can be successfully manufactured to contain up to 30% phase-change material (PCM), or wax, thus enabling this common building material to serve as a thermal energy storage device. The PCM wallboard was analyzed for passive solar applications and found to save energy with a reasonable payback time period of five years. Further evaluations of the wallboard are reported in this paper. This analysis looks at potential applications of PCM wallboard as a load management device and as a comfort enhancer. Results show that the wallboard is ineffective in modifying the comfort level but canmore » provide significant load management relief. In some applications the load management strategy also serves to save a small amount of energy, in others there is a small energy penalty.« less

  12. Advanced Sorbent Structure Recovery of REEs, Precious Metals and Other Valuable Metals from Geothermal Waters and Its Associated Technoeconomics

    DOE Data Explorer

    Addleman, Shane; Chouyyok, Wilaiwan; Palo, Daniel; Dunn, Brad M.; Brann, Michelle; Billingsley, Gary; Johnson, Darren; Nell, Kara M.

    2017-05-25

    This work evaluates, develops and demonstrates flexible, scalable mineral extraction technology for geothermal brines based upon solid phase sorbent materials with a specific focus upon rare earth elements (REEs). The selected organic and inorganic sorbent materials demonstrated high performance for collection of trace REEs, precious and valuable metals beyond commercially available sorbents. This report details the organic and inorganic sorbent uptake, performance, and collection efficiency results for La, Eu, Ho, Ag, Cu and Zn, as well as the characterization of these select sorbent materials. The report also contains estimated costs from an in-depth techno-economic analysis of a scaled up separation process. The estimated financial payback period for installing this equipment varies between 3.3 to 5.7 years depending on the brine flow rate of the geothermal resource.

  13. Retention payoff-based cost per day open regression equations: Application in a user-friendly decision support tool for investment analysis of automated estrus detection technologies.

    PubMed

    Dolecheck, K A; Heersche, G; Bewley, J M

    2016-12-01

    Assessing the economic implications of investing in automated estrus detection (AED) technologies can be overwhelming for dairy producers. The objectives of this study were to develop new regression equations for estimating the cost per day open (DO) and to apply the results to create a user-friendly, partial budget, decision support tool for investment analysis of AED technologies. In the resulting decision support tool, the end user can adjust herd-specific inputs regarding general management, current reproductive management strategies, and the proposed AED system. Outputs include expected DO, reproductive cull rate, net present value, and payback period for the proposed AED system. Utility of the decision support tool was demonstrated with an example dairy herd created using data from DairyMetrics (Dairy Records Management Systems, Raleigh, NC), Food and Agricultural Policy Research Institute (Columbia, MO), and published literature. Resulting herd size, rolling herd average milk production, milk price, and feed cost were 323 cows, 10,758kg, $0.41/kg, and $0.20/kg of dry matter, respectively. Automated estrus detection technologies with 2 levels of initial system cost (low: $5,000 vs. high: $10,000), tag price (low: $50 vs. high: $100), and estrus detection rate (low: 60% vs. high: 80%) were compared over a 7-yr investment period. Four scenarios were considered in a demonstration of the investment analysis tool: (1) a herd using 100% visual observation for estrus detection before adopting 100% AED, (2) a herd using 100% visual observation before adopting 75% AED and 25% visual observation, (3) a herd using 100% timed artificial insemination (TAI) before adopting 100% AED, and (4) a herd using 100% TAI before adopting 75% AED and 25% TAI. Net present value in scenarios 1 and 2 was always positive, indicating a positive investment situation. Net present value in scenarios 3 and 4 was always positive in combinations using a $50 tag price, and in scenario 4, the $5,000, $100, and 80% combination. Overall, the payback period ranged from 1.6 yr to greater than 10 yr. Investment analysis demonstration results were highly dependent on assumptions, especially AED system initial investment and labor costs. Dairy producers can use herd-specific inputs with the cost per day open regression equations and the decision support tool to estimate individual herd results. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. DEEP: A Database of Energy Efficiency Performance to Accelerate Energy Retrofitting of Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoon Lee, Sang; Hong, Tianzhen; Sawaya, Geof

    The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions andmore » 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit. DEEP will be migrated into the DEnCity - DOE’s Energy City, which integrates large-scale energy data for multi-purpose, open, and dynamic database leveraging diverse source of existing simulation data.« less

  15. Solar energy system economic evaluation for Elcam-Tempe, Tempe, Arizona and Elcam-San Diego, San Diego, California

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The long term economic performance of the solar energy system at its installation site is analyzed and four additional locations selected to demonstrate the viability of the design over a broad range of environmental and economic conditions. The economic analysis of the solar energy systems that were installed at Tempe, Arizona and San Diego, California, is developed for these and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f Chart design procedure with inputs based on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over a projected twenty year life: life cycle savings; year of positive savings; and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainites in constituent system and economic variables is also investigated. The results demonstrate that the solar energy system is economically viable at all of the sites for which the analysis was conducted.

  16. Wind energy Computerized Maintenance Management System (CMMS) : data collection recommendations for reliability analysis.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, Valerie A.; Ogilvie, Alistair B.

    2012-01-01

    This report addresses the general data requirements for reliability analysis of fielded wind turbines and other wind plant equipment. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific data recommendations for a Computerized Maintenance Management System (CMMS) to support automated analysis. This data collection recommendations report was written by Sandia National Laboratories to address the general data requirements for reliability analysis of operating wind turbines. This report is intended to help develop a basic understanding of the data needed for reliability analysis frommore » a Computerized Maintenance Management System (CMMS) and other data systems. The report provides a rationale for why this data should be collected, a list of the data needed to support reliability and availability analysis, and specific recommendations for a CMMS to support automated analysis. Though written for reliability analysis of wind turbines, much of the information is applicable to a wider variety of equipment and analysis and reporting needs. The 'Motivation' section of this report provides a rationale for collecting and analyzing field data for reliability analysis. The benefits of this type of effort can include increased energy delivered, decreased operating costs, enhanced preventive maintenance schedules, solutions to issues with the largest payback, and identification of early failure indicators.« less

  17. Management and Feasibility Analysis of Smoked Fish Business in Ambon

    NASA Astrophysics Data System (ADS)

    Nanlohy, Hellen; Apituley, Yolanda M. T. N.; Tapotubun, Alfonsina M.; Reiuwpassa, Frederik; Matrutty, Theodora E. A. A.

    2017-10-01

    This research aims to examine management and feasibility aspects of smoked fish business in Ambon. By using survey, this research focused on smoked fish business in Negeri Hative Kecil and Silale, known as dried fish producer villages.Primary and secondary data collected by using interview, observation, and recording. Analysis methods used are qualitative descriptive analysis and business feasibility analysis covers NPV, Payback Period (PP), and Break Even Point (BEP). The result shows that most of the smoked fish businessmen do not apply the proper management in their business. Two to three people do all the works (from production to marketing) without a clear job description. Feasibility analysis for smoked fish business in Negeri Hative Kecil shows that NPV is 21.501.053,- PP is 58 days, and Benefit Cost Ratio (B/C) is 1,06. BEP Production is 1,455 kg, and BEP Price is IDR 19,941, while the feasibility analysis for smoked fish business in Desa Silale shows that NPV is 30.745.837,-, PP is 24 days and Benefit Cost Ratio (B/C) is 1,41. BEP Production is 988 kg, and BEP Price is IDR 7,966. Based on the result, the two smoked fish business in Ambon is feasible to be developed. However, good management with clear job description should be applied to improve the business.

  18. A Review of Education and Training for Officers (RETO). Volume 2. Career Progression.

    DTIC Science & Technology

    1978-06-30

    any control over the academic disciplines being pursued by scholarship students resulted in a few ROTC graduates with disciplines of no reasonable...direct application to the military environment. Providing scholarship winners a list of academic majors from which to choose and thereafter channel their... academic endeavors, would provide a better link between precommissioning education and known Army requirements. (2) introducing a "pay-back" option

  19. Fresh air indoors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kull, K.

    1988-09-01

    This article describes and compares ventilation systems for the control of indoor air pollution in residential housing. These include: local exhaust fans, whole-house fans, central exhaust with wall ports, and heat-recovery central ventilation (HRV). HRV's have a higher initial cost than the other systems but they are the only ones that save energy. Homeowners are given guidelines for choosing the system best suited for their homes in terms of efficiency and payback period.

  20. Process gas hear recovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, W.M.; Thurner, R.P.

    1977-01-01

    In considering the use of regenerative and recuperative heat exchangers for process-gas heat recovery general information regarding heat-exchanger effectiveness versus initial capital investment and operating costs is discussed. Specific examples for preheating combustion air for process furnaces and for using primary and secondary heat exchangers in conjunction with an air-pollution-control system for drying and curing ovens cover basic heat-exchanger design and application considerations as well as investment-payback factors.

  1. Critical Code: Software Producibility for Defense

    DTIC Science & Technology

    2010-01-01

    the hazard of a single system failing can often be associated with a much larger aggregate of systems, often spread across a wide geography. The...four words: fault, error, failure, and hazard . These are defined and illustrated in Box 4.2. Information Loss and Traceability As noted above, the...design information when payback is uncertain, diffuse , or most likely far in the future. A goal in formulating incentive models that motivate developer

  2. Sustainability Action Planning and Initiatives at Twentynine Palms Marine Corps Air Ground Combat Center (MCAGCC)

    DTIC Science & Technology

    2011-05-01

    Energy and water security/ independence; sustain leadership • Compliance and environmental stewardship (cannot impact training mission...reduction, with efforts underway and cogeneration opportunities 18.3% of energy consumed by facilities is produced or procured from renewable...payback timeframes of ɠ years on existing cogeneration plant and ɛ years on new cogeneration plant Renewable Energy • In FY2010, approximately 6.2% of

  3. Selling solar energy as a cash crop

    NASA Technical Reports Server (NTRS)

    Brantley, L. W.

    1978-01-01

    The paper considers solar energy equipment which, besides supplying energy for farmstead needs, would convert excess energy to a transportable form to sell to a power company. It is suggested that a concentrating two-axis tracking spheroidal collector would cost as little as $5/sq ft if mass produced. The proposed system uses 7854 sq ft of collector area (set in about one acre of land), and the cost payback is estimated.

  4. Retrofitting LID Practices into Existing Neighborhoods: Is It Worth It?

    NASA Astrophysics Data System (ADS)

    Wright, Timothy J.; Liu, Yaoze; Carroll, Natalie J.; Ahiablame, Laurent M.; Engel, Bernard A.

    2016-04-01

    Low-impact development (LID) practices are gaining popularity as an approach to manage stormwater close to the source. LID practices reduce infrastructure requirements and help maintain hydrologic processes similar to predevelopment conditions. Studies have shown LID practices to be effective in reducing runoff and improving water quality. However, little has been done to aid decision makers in selecting the most effective practices for their needs and budgets. The long-term hydrologic impact assessment LID model was applied to four neighborhoods in Lafayette, Indiana using readily available data sources to compare LID practices by analyzing runoff volumes, implementation cost, and the approximate period needed to achieve payback on the investment. Depending on the LID practice and adoption level, 10-70 % reductions in runoff volumes could be achieved. The cost per cubic meter of runoff reduction was highly variable depending on the LID practice and the land use to which it was applied, ranging from around 3 to almost 600. In some cases the savings from reduced runoff volumes paid back the LID practice cost with interest in less than 3 years, while in other cases it was not possible to generate a payback. Decision makers need this information to establish realistic goals and make informed decisions regarding LID practices before moving into detailed designs, thereby saving time and resources.

  5. Managerial preferences in relation to financial indicators regarding the mitigation of global change.

    PubMed

    Maroušek, Josef; Hašková, Simona; Zeman, Robert; Vaníčková, Radka

    2015-02-01

    Biochar is a soil-improving substrate made from phytomass pyrolysis. In Southeast Asia, its application decreases due to the long-term growth of biochar cost and thus caused further prolongation of the payback period. In the Euro-American civilization the biochar application is already almost forgotten once it has been much earlier recognized that the crop yields can be increased much faster with higher doses of nutrients and other agrochemicals. The payback period can be expected in decades. Such a long-time investment into soil fertility raises also many ethical questions. The final decision combines issues of social responsibility, risk and other financial indicators as well as personal preferences and more. The attitudes of Western and Central European decision makers in the agriculture business segment were analyzed on the basis of electronic questionnaire survey and a subsequent interview through their local unions. According to the data, most of them did not know about the possibilities of a more environmentally friendly approach to soil enhancement based on the addition of a fertilizer in the form of biochar. Among others, the collected data also shows that the decision makers from Western Europe have a much different ethical approach to the land and financial indicators than the Central Europeans.

  6. Development of an in-house hospital information system in a hospital in Pakistan.

    PubMed

    Sultan, Faisal; Aziz, Muhammad Tahir; Khokhar, Idrees; Qadri, Hussain; Abbas, Manzar; Mukhtar, Amir; Manzoor, Waqar; Yusuf, Muhammed Aasim

    2014-03-01

    To review our experience of development and implementation of an electronic hospital information system, its costs and return on investment as well as incorporation of some key quality standards. Cost and saving trends of the project were calculated using different tools including project expense, cost saving through cessation of printing radiology films and paper. Net present value with payback period was utilized to evaluate the efficiency of the health information systems. Qualitative improvements in different healthcare functions were also analyzed. The total saving of the project was approximately US$ 5.1 million with net saving of US$ 3.5 million for the period from 2001 to 2011. The net present value of the project is US$ 3.2 million with a payback period of 3.4 years. Electronic hospital information systems and health records hold the potential to be useful tools for quality improvement and error reduction. Adoption of such systems, however, has been slow and erratic, worldwide. Utilizing the concept of net present value, development of such a system may be financially viable for some institutions. Instead of simply replacing paper, these systems may also be used to improve information management and improve quality of patient care. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Life cycle implications of urban green infrastructure.

    PubMed

    Spatari, Sabrina; Yu, Ziwen; Montalto, Franco A

    2011-01-01

    Low Impact Development (LID) is part of a new paradigm in urban water management that aims to decentralize water storage and movement functions within urban watersheds. LID strategies can restore ecosystem functions and reduce runoff loadings to municipal water pollution control facilities (WPCF). This research examines the avoided energy and greenhouse gas (GHG) emissions of select LID strategies using life cycle assessment (LCA) and a stochastic urban watershed model. We estimate annual energy savings and avoided GHG emissions of 7.3 GJ and 0.4 metric tons, respectively, for a LID strategy implemented in a neighborhood in New York City. Annual savings are small compared to the energy and GHG intensity of the LID materials, resulting in slow environmental payback times. This preliminary analysis suggests that if implemented throughout an urban watershed, LID strategies may have important energy cost savings to WPCF, and can make progress towards reducing their carbon footprint. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Carbon black dispersion pre-plating technology for printed wire board manufacturing. Final technology evaluation report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Folsom, D.W.; Gavaskar, A.R.; Jones, J.A.

    1993-10-01

    The project compared chemical use, waste generation, cost, and product quality between electroless copper and carbon-black-based preplating technologies at the printed wire board (PWB) manufacturing facility of McCurdy Circuits in Orange, CA. The carbon-black based preplating technology evaluated is used as an alternative process for electroless copper (EC) plating of through-holes before electrolytic copper plating. The specific process used at McCurdy is the BlackHole (BH) technology process, which uses a dispersion of carbon black in an aqueous solution to provide a conductive surface for subsequent electrolytic copper plating. The carbon-black dispersion technology provided effective waste reduction and long-term cost savings.more » The economic analysis determined that the new process was cost efficient because chemical use was reduced and the process proved more efficient; the payback period was less than 4 yrs.« less

  9. Overview of waste heat utilization systems

    NASA Technical Reports Server (NTRS)

    Bailey, M. M.

    1984-01-01

    The heavy truck diesel engine rejects a significant fraction of its fuel energy in the form of waste heat. Historically, the Department of Energy has supported technology efforts for utilization of the diesel exhaust heat. Specifically, the Turbocompound and the Organic Rankine Cycle System (ORCS) have demonstrated that meaningful improvements in highway fuel economy can be realized through waste heat utilization. For heat recovery from the high temperature exhaust of future adiabatic diesel engines, the DOE/NASA are investigating a variety of alternatives based on the Rankine, Brayton, and Stirling power cycles. Initial screening results indicate that systems of this type offer a fuel savings advantage over the turbocompound system. Capital and maintenance cost projections, however, indicate that the alternative power cycles are not competitive on an economic payback basis. Plans call for continued analysis in an attempt to identify a cost effective configuration with adequate fuel savings potential.

  10. Low-Cost Phase Change Material for Building Envelopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abhari, Ramin

    2015-08-06

    A low-cost PCM process consisting of conversion of fats and oils to PCM-range paraffins, and subsequent “encapsulation” of the paraffin using conventional plastic compounding/pelletizing equipment was demonstrated. The PCM pellets produced were field-tested in a building envelope application. This involved combining the PCM pellets with cellulose insulation, whereby 33% reduction in peak heat flux and 12% reduction in heat gain was observed (average summertime performance). The selling price of the PCM pellets produced according to this low-cost process is expected to be in the $1.50-$3.00/lb range, compared to current encapsulated PCM price of about $7.00/lb. Whole-building simulations using corresponding PCMmore » thermal analysis data suggest a payback time of 8 to 16 years (at current energy prices) for an attic insulation retrofit project in the Phoenix climate area.« less

  11. Analysis of community income on suren (Toona sureni (Blume) Merr.) and cacao crops (Theobroma cacao L.) in Simalungun, North Sumatera-Indonesia

    NASA Astrophysics Data System (ADS)

    Latifah, S.; Afifuddin, Y.; Widya, S.

    2018-02-01

    Agroforestry is the management and integration of trees, crops and/or livestock on the same plot of land and can be an integral component of productive agriculture. It may include existing native forests and forests established by landholders. The study was conducted in Mekar Sari Raya village, Panei sub, Simalungun regency, North Sumatera. This study aims to gain the ability to use agroforestry in suren crops and cocoa that provides benefits to farmers and the feasibility of the model farm. The study site has Net Present Value (NPV) is 2,670,306,905 ( IDR) for 15 of year, Gross B/C Ratio (BCR) is 2.3; Internal Rate of Return ( IRR) is 28 %; and Payback Period (PP) for 5 years 4 months 24 days. Agroforestry using commodities cacao and suren crops are financially feasible to be cultivated and developed.

  12. Experience with ethylene plant computer control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nasi, M.; Darby, M.L.; Sourander, M.

    This article discusses the control strategies, results and opinions of management and operations of a computer based ethylene plant control system. The ethylene unit contains 9 cracking heaters, and its nameplate capacity is 200,000 tpa ethylene. Reports on control performance during different unit loading and using different feedstock types. By converting the yield and utility consumption benefits due to computer control into monetary units, the payback time of the system is less than 2 yrs.

  13. Sustainability-Related Publications: Calendar Years 2014 - 2015

    DTIC Science & Technology

    2016-03-03

    five 100 kW wind turbines . The best performing turbine assessed at a hub height of 37 m could provide 52% of the site’s annual electric power needs...with a payback of approxi- mately 18 to 19.6 years. However, extrapo- lated long-term wind speeds suggest the best performing turbine assessed could... Wind Resource Assessment: Center Strafford Training Center, http://acwc.sdp.sirsi.net/client/search/asset/1047667 The New Hampshire Army National

  14. Diminishing Manufacturing Sources and Material Shortages (DMSMS) Guidebook

    DTIC Science & Technology

    2006-11-01

    www.dau.mil/registrar/enroll.aspx DoD Acquisition, Technology, and Logistics (AT&L) Integrated Framework Chart (IFC) lifecycle activities and...ROI) and Break Even Point ( BEP ). Two analysts could look at the same data and generate different outcomes if they use different assumptions or...principal output of the BCA is the Break Even Point ( BEP ), which shows the payback period of an alternative. It is found from a plot of the

  15. Survey State of the Art: Electrical Load Management Techniques and Equipment.

    DTIC Science & Technology

    1986-10-31

    automobiles and even appliances. Applications in the area of demand and energy management have been multifaceted, given the needs involved and rapid paybacks...copy of the programming to be reloaded into the controller at any time and by designing this module with erasable and reprogrammable memory, the...points and performs DDC programming is stored in (direct digital control) of output reprogrammable , permanent memory points. A RIM may accommodate up

  16. Extended use of grey water for irrigating home gardens in an arid environment.

    PubMed

    Al-Ismaili, Abdulrahim M; Ahmed, Mushtaque; Al-Busaidi, Ahmed; Al-Adawi, Seif; Tandlich, Roman; Al-Amri, Mohammed

    2017-05-01

    The use of treated grey water (GW) for home gardens, peri-urban agriculture and landscaping is becoming popular in many water stressed countries such as Oman. This study aims to investigate the treatment efficacy, health and chemical concerns, cost-benefits and maintenance protocol of a GW treatment system as well as the effect of irrigation with GW on crop yield. Therefore, a decentralized homemade GW treatment system was installed in a newly constructed house in Muscat, Oman and studied over a 2-year period. The treated GW was found to be suitable for irrigation as per Omani standards. GW when mixed with kitchen effluent substituted the use of nutrient supplements for plants and did not show any harmful chemical or biological contamination. The capital cost of the system was around US $980, and the annual operating cost was US $78 with annual income and savings from the system being around US $572 indicating a payback period of nearly 2 years. It was found that the system required simple but regular maintenance particularly cleaning of the top layer of the filter. It can be concluded from this study that such a GW system should be technically, economically and environmentally feasible in Oman. Also, wider acceptance by the general public to the idea of GW reuse will help in mitigating the water shortage problem of the country to some extent.

  17. Feasibility study for retrofitting biogas cogeneration systems to district heating in South Korea.

    PubMed

    Chung, Mo; Park, Hwa-Choon

    2015-08-01

    A feasibility study was performed to assess the technical and economic merits of retrofitting biogas-based cogeneration systems to district heating networks. Three district heating plants were selected as candidates for accommodating heat recovery from nearby waste treatment stations, where a massive amount of biogas can be produced on a regular basis. The scenario involves constructing cogeneration systems in each waste treatment station and producing electricity and heat. The amounts of biogas production for each station are estimated based on the monthly treatment capacities surveyed over the most recent years. Heat produced by the cogeneration system is first consumed on site by the waste treatment system to keep the operating temperature at a proper level. If surplus heat is available, it will be transported to the nearest district heating plant. The year-round operation of the cogeneration system was simulated to estimate the electricity and heat production. We considered cost associated with the installation of the cogeneration system and piping as initial investments. Profits from selling electricity and recovering heat are counted as income, while costs associated with buying biogas are expenses. Simple payback periods of 2-10 years were projected under the current economic conditions of South Korea. We found that most of the proposed scenarios can contribute to both energy savings and environmental protection. © The Author(s) 2015.

  18. Services under siege--the restructuring imperative.

    PubMed

    Roach, S S

    1991-01-01

    Recent job losses in the U.S. service sector do not reflect a temporary recession. Those jobs are gone, the result of a massive restructuring of the sector that is just getting under way. The explanation for the restructuring is quite simple. Until recently, services have been shielded by regulation and confronted by few foreign competitors. They have allowed their white-collar payrolls to become bloated, their investment in information technology to outstrip the paybacks, and their productivity to stagnate. Now competition is heating up and exposing these inefficiencies. Just as intense competition forced the restructuring of Smokestack America in the 1980s, deregulation and foreign direct investment are shaking out service companies that cannot confront their shortcomings. The need for sweeping change in the service sector may come as a great shock to Americans who saw services as the means to continued economic prosperity. But there is a painful irony at work: job creation, the very thing proponents use to demonstrate the U.S. service sector's strength, is in fact a symptom of the sector's chronic neglect of economic efficiency. It is precisely that neglect that makes the service sector vulnerable as the race for market share intensifies and new players shift the terms of competition. Services must respond to the new competitive environment, but not by indiscriminate cost cutting. Instead, they should balance financial discipline with a comprehensive and immediate reexamination of strategy.

  19. Thermal Energy Storage using PCM for Solar Domestic Hot Water Systems: A Review

    NASA Astrophysics Data System (ADS)

    Khot, S. A.; Sane, N. K.; Gawali, B. S.

    2012-06-01

    Thermal energy storage using phase chase materials (PCM) has received considerable attention in the past two decades for time dependent energy source such as solar energy. From several experimental and theoretical analyses that have been made to assess the performance of thermal energy storage systems, it has been demonstrated that PCM-based systems are reliable and viable options. This paper covers such information on PCMs and PCM-based systems developed for the application of solar domestic hot water system. In addition, economic analysis of thermal storage system using PCM in comparison with conventional storage system helps to validate its commercial possibility. From the economic analysis, it is found that, PCM based solar domestic hot water system (SWHS) provides 23 % more cumulative and life cycle savings than conventional SWHS and will continue to perform efficiently even after 15 years due to application of non-metallic tank. Payback period of PCM-based system is also less compared to conventional system. In conclusion, PCM based solar water heating systems can meet the requirements of Indian climatic situation in a cost effective and reliable manner.

  20. Small modular reactor: First-of-a-Kind (FOAK) and Nth-of-a-Kind (NOAK) Economic Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boldon, Lauren M.; Sabharwall, Piyush

    2014-08-01

    Small modular reactors (SMRs) refer to any reactor design in which the electricity generated is less than 300 MWe. Often medium sized reactors with power less than 700 MWe are also grouped into this category. Internationally, the development of a variety of designs for SMRs is booming with many designs approaching maturity and even in or nearing the licensing stage. It is for this reason that a generalized yet comprehensive economic model for first of a kind (FOAK) through nth of a kind (NOAK) SMRs based upon rated power, plant configuration, and the fiscal environment was developed. In the model,more » a particular project’s feasibility is assessed with regards to market conditions and by commonly utilized capital budgeting techniques, such as the net present value (NPV), internal rate of return (IRR), Payback, and more importantly, the levelized cost of energy (LCOE) for comparison to other energy production technologies. Finally, a sensitivity analysis was performed to determine the effects of changing debt, equity, interest rate, and conditions on the LCOE.« less

  1. Development of cost-effective surfactant flooding technology, Quarterly report, October 1995--December 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, G.A.; Sepehrnoori, K.

    1995-12-31

    The objective of this research is to develop cost-effective surfactant flooding technology by using simulation studies to evaluate and optimize alternative design strategies taking into account reservoir characteristics process chemistry, and process design options such as horizontal wells. Task 1 is the development of an improved numerical method for our simulator that will enable us to solve a wider class of these difficult simulation problems accurately and affordably. Task 2 is the application of this simulator to the optimization of surfactant flooding to reduce its risk and cost. In this quarter, we have continued working on Task 2 to optimizemore » surfactant flooding design and have included economic analysis to the optimization process. An economic model was developed using a spreadsheet and the discounted cash flow (DCF) method of economic analysis. The model was designed specifically for a domestic onshore surfactant flood and has been used to economically evaluate previous work that used a technical approach to optimization. The DCF model outputs common economic decision making criteria, such as net present value (NPV), internal rate of return (IRR), and payback period.« less

  2. Environmental and Economic Performance of Commercial-scale Solar Photovoltaic Systems: A Field Study of Complex Energy Systems at the Desert Research Institute (DRI)

    NASA Astrophysics Data System (ADS)

    Liu, X.

    2014-12-01

    Solar photovoltaic (PV) systems are being aggressively deployed at residential, commercial, and utility scales to complement power generation from conventional sources. This is motivated both by the desire to reduce carbon footprints and by policy-driven financial incentives. Although several life cycle analyses (LCA) have investigated environmental impacts and energy payback times of solar PV systems, most results are based on hypothetical systems rather than actual, deployed systems that can provide measured performance data. Over the past five years, Desert Research Institute (DRI) in Nevada has installed eight solar PV systems of scales from 3 to 1000 kW, the sum of which supply approximately 40% of the total power use at DRI's Reno and Las Vegas campuses. The goal of this work is to explore greenhouse gas (GHG) impacts and examine the economic performance of DRI's PV systems by developing and applying a comprehensive LCA and techno-economic (TEA) model. This model is built using data appropriate for each type of panel used in the DRI systems. Power output is modeled using the National Renewable Energy Laboratory (NREL) model PVWatts. The performance of PVWatts is verified by the actual measurements from DRI's PV systems. Several environmental and economic metrics are quantified for the DRI systems, including life cycle GHG emissions and energy return. GHG results are compared with Nevada grid-based electricity. Initial results indicate that DRI's solar-derived electricity offers clear GHG benefits compared to conventional grid electricity. DRI's eight systems have GHG intensity values of 29-56 gCO2e/kWh, as compared to the GHG intensity of 212 gCO2e/kWh of national average grid power. The major source of impacts (82-92% of the total) is the upstream life cycle burden of manufacturing PV panels, which are made of either mono-crystalline or multi-crystalline silicon. Given the same type of PV panel, GHG intensity decreases as the scale of the system increases. Energy payback times of DRI's solar PV systems range from 0.5 to 1.5 years. The cost payback time for the DRI PV systems and the cost per ton of CO2 avoided by replacing Nevada-specific electrical power will be determined. The sensitivity of these environmental and economic impacts with respect to specific model parameters is being investigated.

  3. Higher mortgages, lower energy bills: The real economics of buying an energy-efficient home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mills, E.

    1987-02-01

    To measure the actual costs and benefits of buying an energy- efficient home, it is necessary to employ a cash-flow model that accounts for mortgage interest and other charges associated with the incremental costs of conservation measures. The ability to make payments gradually over the term of a mortgage, energy savings, and tax benefits contribute to increased cost effectiveness. Conversely, financial benefits are reduced by interest payments, insurance, taxes, and various fees linked to the (higher) sale price of an energy-efficient home. Accounting for these factors can yield a strikingly different picture from those given by commonly used ''engineering'' indicators,more » such as simple payback time, internal rate of return, or net present value (NPV), which are based solely on incremental costs and energy savings. This analysis uses actual energy savings data and incremental construction costs to evaluate the mortgage cash flow for 79 of the 144 energy-efficient homes constructed in Minnesota under the Energy-Efficient Housing Demonstration Program (EEHDP) initiated in 1980 by the Minnesota Housing Finance Agency. Using typical lending terms and fees, we find that the mean mortgage-NPV derived from the homeowners' real cash flow (including construction and financing costs) is 20% lower than the standard engineering-NPV of the conservation investment: $7981 versus $9810. For eight homes, the mortgage-NPV becomes negative once we account for the various mortgage-related effects. Sensitivities to interest rates, down payment, loan term, and marginal tax rate are included to illustrate the often large impact of alternative assumptions about these parameters. The most dramatic effect occurs when the loan term is reduced from 30 to 15 years and the mortgage NPV falls to -$925. We also evaluate the favorable Federal Home Administration (FHA) terms actually applied to the EEHDP homes. 8 refs., 4 figs., 3 tabs.« less

  4. City of Raleigh, Wilders Grove Service Center, Solid Waste Services Facility. Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert Cox; Bill Black; Battle, Fred

    Final Report for DOE Grant EE0002808. Grant award was for technology demonstration of geothermal energy systems. One of the major objectives identified for the demonstration portion of the grant was to prove the viability of Ground Source Heat Pump (GSHP) systems in significantly reducing energy usage of HVAC and domestic water heating systems compared to traditional systems. Data were monitored and conclusions drawn, including estimating payback timeframes and documenting lessons learned.

  5. Problems of Waste Management at Poultry Plants and Ways to Address Them

    NASA Astrophysics Data System (ADS)

    Lazareva, L. P.; Kostryakova, O. N.

    2017-11-01

    The paper analyzes scientific literature on manure recycling and systems of waste management at two poultry plants that use different technologies of poultry housing and manure disposal and calculates the volumes of waste generation for two plants. The authors suggest an economically and ecologically efficient manure utilization technology, consider the feasibility of replacing traditional fuel with the one produced by manure recycling and calculate expected profits and the payback time of equipment.

  6. Study on Use of Fuel-Cell Auxiliary Power Units in Refrigerator Cars Employed for Delivery to Convenience Store

    NASA Astrophysics Data System (ADS)

    Katayama, Noboru; Kamiyama, Hideyuki; Kogoshi, Sumio; Kudo, Yusuke; Fukada, Takafumi; Ogawa, Makoto

    The use of fuel-cell auxiliary power units (FC-APU) in refrigerator cars employed delivery to for convenience store delivery has been studied. The delivery pattern is assumed to be a typical pattern that includes driving between convenience stores or between a delivery center and a convenience store, unloading, driver's lunch break. The M15 driving mode, which simulates the driving condition in urban areas, is used as the driving mode in the delivery pattern. The FC-APU system includes a proton-exchange membrane fuel cell (PEFC) module, an inverter, and DC/DC converter. Bench tests of the FC-APU are performed to determine the hydrogen fuel consumption rate and the energy efficiency; these values depend on the output power of the PEFC module. The calculated relationship between the output power and fuel consumption rate of a current used system, which consists of an alternator and a secondary battery, are used to estimate the energy efficiency of the current used system. On the basis of the measurement data in this study and the results for the model proposed by Brodric et al. [C. J. Brodrick et al., Trans. Res. D, vol 7, pp. 303 (2002)], the payback period is calculated. The results indicate that the payback period would be 2.1 years when the FC-APU operates at a load of 70%.

  7. Combined Space and Water Heating: Next Steps to Improved Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B. Schoenbauer; Bohac, D.; Huelman, P.

    2016-07-13

    A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%–4.3% (20–40 therms/year) savings for storage andmore » hybrid water heater combi systems operated in moderate-load homes. The full modulation control showed additional savings over set point control (in high-load homes almost doubling the savings: 4%–5% over the no-control case). At the time of installation the reset control can be implemented for $200–$400, which would provide paybacks of 6–25 years for low-load houses and 3–15 years for high-load houses. Full modulation implementation costs would be similar to the outdoor reset and would provide paybacks of 5-½–20 years for low-load houses and 2-½–10 years for high-load houses.« less

  8. Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting in Leavenworth, KS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myer, Michael; Kinzey, Bruce R.; Curry, Ku'uipo

    2011-05-06

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a commercial parking lot lighting application, under the U.S. Department of Energy (DOE) Solid-State Lighting Technology GATEWAY Demonstration Program. The parking lot is for customers and employees of a Walmart Supercenter in Leavenworth, Kansas and this installation represents the first use of the LED Parking Lot Performance Specification developed by the DOE’s Commercial Building Energy Alliance. The application is a parking lot covering more than a half million square feet, lighted primarily by light-emitting diodes (LEDs). Metal halide wall packs were installed along themore » building facade. This site is new construction, so the installed baseline(s) were hypothetical designs. It was acknowledged early on that deviating from Walmart’s typical design would reduce the illuminance on the site. Walmart primarily uses 1000W pulse-start metal halide (PMH) lamps. In order to provide a comparison between both typical design and a design using conventional luminaires providing a lower illuminance, a 400W PMH design was also considered. As mentioned already, the illuminance would be reduced by shifting from the PMH system to the LED system. The Illuminating Engineering Society of North America (IES) provides recommended minimum illuminance values for parking lots. All designs exceeded the recommended illuminance values in IES RP-20, some by a wider margin than others. Energy savings from installing the LED system compared to the different PMH systems varied. Compared to the 1000W PMH system, the LED system would save 63 percent of the energy. However, this corresponds to a 68 percent reduction in illuminance as well. In comparison to the 400W PMH system, the LED system would save 44 percent of the energy and provide similar minimum illuminance values at the time of relamping. The LED system cost more than either of the PMH systems when comparing initial costs. However, when the life-cycle costs from energy and maintenance were factored into the scenario, the LED system had lower costs at the end of a 10-year analysis period. The LED system had a 6.1 year payback compared to the 1000W PMH system and a 7.5 year payback versus the 400W PMH system. The costs reflect high initial cost for the LED luminaire, plus more luminaires and (subsequently) more poles for the LED system. The other major issue affecting cost effectiveness was that Leavenworth, Kansas has very low electricity costs. The melded rate for this site was $0.056 per kWh for electricity. However, if the national electricity rate of $0.1022/kWh was used the payback would change to between four and five years for the LED system. This demonstration met the GATEWAY requirements of saving energy, matching or improving illumination, and being cost effective. The project also demonstrated that the Commercial Building Energy Alliance (CBEA) specification works in practice. Walmart appreciated having an entire site lighted by LEDs to gain more experience with the technology. Walmart is reviewing the results of the demonstration as they consider their entire real estate portfolio.« less

  9. Utilities Privatization-Is the US Army on the Right Circuit?

    DTIC Science & Technology

    2009-04-29

    is interested, the DoD must use competitive procedures to make the selection. DoD must receive an amount equal to the fair market value (FMV) of the...Aid of Construction versus Fair Market Value Issue and Discussion The first utilities privatization issue existing today centers around the payment of...a 10 percent depreciation rate of the system value so the contract length of the pay-back is 10 years. The contractor’s interest rate or rate of

  10. Capital planning for clinical integration.

    PubMed

    Grauman, Daniel M; Neff, Gerald; Johnson, Molly Martha

    2011-04-01

    When assessing the financial implications of a physician alignment and clinical integration initiative, a hospital should measure the initiative's potential ROI, perhaps best using a combination of net present value and payback period. The hospital should compare its own historical and projected performance with rating agency median benchmarks for key financial indicators of profitability, debt service, capital and cash flow, and liquidity. The hospital should also consider potential indirect benefits, such as retained outpatient/ancillary revenue, increased inpatient revenue, improved cost control, and improved quality and reporting transparency.

  11. Improving customer service on the phone: a multidimensional effort with a big payback.

    PubMed

    Brown, Sally

    2005-01-01

    Telephone communications are the first line of contact for new patients and established patients who require ongoing care. They also represent one of many Achilles' heels for practices. Poor handling of phones can be inefficient and costly. This article outlines The Vancouver Clinic's experience in viewing the problems, identifying the issues, and resolving them with the minimum of expense and personnel disruption. It documents the marked lowering of call abandonment rates and the decrease in call-to-answer times.

  12. Advanced propulsion for LEO-Moon transport. 3: Transportation model. M.S. Thesis - California Univ.

    NASA Technical Reports Server (NTRS)

    Henley, Mark W.

    1992-01-01

    A simplified computational model of low Earth orbit-Moon transportation system has been developed to provide insight into the benefits of new transportation technologies. A reference transportation infrastructure, based upon near-term technology developments, is used as a departure point for assessing other, more advanced alternatives. Comparison of the benefits of technology application, measured in terms of a mass payback ratio, suggests that several of the advanced technology alternatives could substantially improve the efficiency of low Earth orbit-Moon transportation.

  13. Understanding factors associated with the translation of cardiovascular research: a multinational case study approach

    PubMed Central

    2014-01-01

    Background Funders of health research increasingly seek to understand how best to allocate resources in order to achieve maximum value from their funding. We built an international consortium and developed a multinational case study approach to assess benefits arising from health research. We used that to facilitate analysis of factors in the production of research that might be associated with translating research findings into wider impacts, and the complexities involved. Methods We built on the Payback Framework and expanded its application through conducting co-ordinated case studies on the payback from cardiovascular and stroke research in Australia, Canada and the United Kingdom. We selected a stratified random sample of projects from leading medical research funders. We devised a series of innovative steps to: minimize the effect of researcher bias; rate the level of impacts identified in the case studies; and interrogate case study narratives to identify factors that correlated with achieving high or low levels of impact. Results Twenty-nine detailed case studies produced many and diverse impacts. Over the 15 to 20 years examined, basic biomedical research has a greater impact than clinical research in terms of academic impacts such as knowledge production and research capacity building. Clinical research has greater levels of wider impact on health policies, practice, and generating health gains. There was no correlation between knowledge production and wider impacts. We identified various factors associated with high impact. Interaction between researchers and practitioners and the public is associated with achieving high academic impact and translation into wider impacts, as is basic research conducted with a clinical focus. Strategic thinking by clinical researchers, in terms of thinking through pathways by which research could potentially be translated into practice, is associated with high wider impact. Finally, we identified the complexity of factors behind research translation that can arise in a single case. Conclusions We can systematically assess research impacts and use the findings to promote translation. Research funders can justify funding research of diverse types, but they should not assume academic impacts are proxies for wider impacts. They should encourage researchers to consider pathways towards impact and engage potential research users in research processes. PMID:24755187

  14. Economic and environmental analysis of standard, high efficiency, rainwater flushed, and composting toilets.

    PubMed

    Anand, C; Apul, D S

    2011-03-01

    The current sanitation technology in developed countries is based on diluting human excreta with large volumes of centrally provided potable water. This approach is a poor use of water resources and is also inefficient, expensive, and energy intensive. The goal of this study was to compare the standard sanitation technology (Scenario 1) with alternative technologies that require less or no potable water use in toilets. The alternative technologies considered were high efficiency toilets flushed with potable water (Scenario 2), standard toilets flushed with rainwater (Scenario 3), high efficiency toilets flushed with rainwater (Scenario 4), and composting toilets (Scenario 5). Cost, energy, and carbon implications of these five design scenarios were studied using two existing University of Toledo buildings. The results showed that alternative systems modeled in Scenarios 2, 4, and 5 were viable options both from an investment and an environmental performance perspective. High efficiency fixtures that use potable water (Scenario 2) is often the most preferred method in high efficiency buildings due to reduced water use and associated reductions in annual water and wastewater costs. However, the cost, energy, and CO(2)EE analyses all showed that Scenarios 4 and 5 were preferable over Scenario 2. Cost payback periods of scenarios 2, 4 and 5 were less than 10 years; in the future, increase in water and wastewater services would further decrease the payback periods. The centralized water and wastewater services have high carbon footprints; therefore if carbon footprint reduction is a primary goal of a building complex, alternative technologies that require less potable water and generate less wastewater can largely reduce the carbon footprint. High efficiency fixtures flushed with rainwater (Scenario 4) and composting toilets (Scenario 5) required considerably less energy than direct energy demands of buildings. However, the annual carbon footprint of these technologies was comparable to the annual carbon footprint from space heating. Similarly, the carbon savings that could be achieved from Scenario 4 or 5 were comparable to a recycling program that can be implemented in buildings. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Understanding factors associated with the translation of cardiovascular research: a multinational case study approach.

    PubMed

    Wooding, Steven; Hanney, Stephen R; Pollitt, Alexandra; Grant, Jonathan; Buxton, Martin J

    2014-04-21

    Funders of health research increasingly seek to understand how best to allocate resources in order to achieve maximum value from their funding. We built an international consortium and developed a multinational case study approach to assess benefits arising from health research. We used that to facilitate analysis of factors in the production of research that might be associated with translating research findings into wider impacts, and the complexities involved. We built on the Payback Framework and expanded its application through conducting co-ordinated case studies on the payback from cardiovascular and stroke research in Australia, Canada and the United Kingdom. We selected a stratified random sample of projects from leading medical research funders. We devised a series of innovative steps to: minimize the effect of researcher bias; rate the level of impacts identified in the case studies; and interrogate case study narratives to identify factors that correlated with achieving high or low levels of impact. Twenty-nine detailed case studies produced many and diverse impacts. Over the 15 to 20 years examined, basic biomedical research has a greater impact than clinical research in terms of academic impacts such as knowledge production and research capacity building. Clinical research has greater levels of wider impact on health policies, practice, and generating health gains. There was no correlation between knowledge production and wider impacts. We identified various factors associated with high impact. Interaction between researchers and practitioners and the public is associated with achieving high academic impact and translation into wider impacts, as is basic research conducted with a clinical focus. Strategic thinking by clinical researchers, in terms of thinking through pathways by which research could potentially be translated into practice, is associated with high wider impact. Finally, we identified the complexity of factors behind research translation that can arise in a single case. We can systematically assess research impacts and use the findings to promote translation. Research funders can justify funding research of diverse types, but they should not assume academic impacts are proxies for wider impacts. They should encourage researchers to consider pathways towards impact and engage potential research users in research processes.

  16. Toward Molecular Engineering of Polymer Glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freed, Karl F.; Xu, Wen-Sheng; Dudowicz, Jacek B.

    Glass formation has been central to fabrication technologies since the dawn of civilization. Glasses not only encompass window panes, the insulation in our homes, the optical fibers supplying our cable TV, and vessels for eating and drinking, but they also include a vast array of ‘‘plastic’’ polymeric materials. Glasses find applications in high technology (e.g., producing microelectronic materials, etc., amorphous semiconductors), and recent advances have created ‘‘plastic metallic glasses’’ that are promising for fabricating everyday structural materials. Many commercially relevant systems, such as microemulsions and colloidal suspensions, have complex molecular structures and thus solidify by glass formation. Despite the importancemore » of understanding the fundamental nature of glass formation for the synthesis of new materials, a predictive molecular theory has been lacking. Much of our understanding of glass formation derives from the analysis of experimental data, a process that has uncovered a number of interesting universal behaviors, namely, relations between properties that are independent of molecular details. However, these empirically derived relations and their limitations remain to be understood on the basis of theories, and, more importantly, there is strong need for theories of the explicit variation with molecular system to enable the rational design and tailoring of new materials. We have recently developed the generalized entropy theory, the only analytic, theory that enables describing the dependence of the properties of glass-formation on monomer molecular structures. These properties include the two central quantities of glass formation, the glass transition temperature and the glass fragility parameter, material dependent properties that govern how a material may be processed (e.g., by extrusion, ink jet, molding, etc.) Our recent works, which are further described below, extend the studies of glass formation in polymer systems to test the theory by directly comparing between the predictions of our generalized entropy theory with experiment and with simulations and to expand the vistas of the theory to describe a wider range of important systems (e.g. glass formation in binary blends and systems with specific interactions) and phenomena that are describable by the generalized entropy theory. In addition, we have addressed longstanding fundamental problems associated with the validity of the Adam-Gibbs theory, one of the underpinnings of the general entropy theory. Theoretical advances to enable describing the properties of glass-formation over a wider class of important polymeric systems, included semi-flexible systems, the more general situation of specific interactions, and more. Our recent work removes the simplest approximation uses the simplest model in which the interaction is approximated by a single, monomer average. Thus, the theory has been extended to allow some variations of the energy parameters between the atoms within the monomers. The theory has also been extended to include all the contributions from chain semi-flexibility. Both projects are extremely difficult, but the payback is that the process of solving the problems developed strong theoretical skills in Dr. Xu, who has recently begun a postdoc position at ORNL. The theory has also been extended to describe glass formation in partially miscible blends, with good general agreement with experiment. Again, the development of the theory presented an extremely difficult problem, but the payback is the development of a theory for a very important class of systems. Another project provides an extremely simple approximation for certain properties of glass formation in polymer melts and should make the theory more accessible to everyone.« less

  17. Biohydrogen production from waste bread in a continuous stirred tank reactor: A techno-economic analysis.

    PubMed

    Han, Wei; Hu, Yun Yi; Li, Shi Yi; Li, Fei Fei; Tang, Jun Hong

    2016-12-01

    Biohydrogen production from waste bread in a continuous stirred tank reactor (CSTR) was techno-economically assessed. The treating capacity of the H 2 -producing plant was assumed to be 2 ton waste bread per day with lifetime of 10years. Aspen Plus was used to simulate the mass and energy balance of the plant. The total capital investment (TCI), total annual production cost (TAPC) and annual revenue of the plant were USD931020, USD299746/year and USD639920/year, respectively. The unit hydrogen production cost was USD1.34/m 3 H 2 (or USD14.89/kg H 2 ). The payback period and net present value (NPV) of the plant were 4.8years and USD1266654, respectively. Hydrogen price and operators cost were the most important variables on the NPV. It was concluded that biohydrogen production from waste bread in the CSTR was feasible for practical application. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Economic analysis and environmental impact assessment of three different fermentation processes for fructooligosaccharides production.

    PubMed

    Mussatto, Solange I; Aguiar, Luís M; Marinha, Mariana I; Jorge, Rita C; Ferreira, Eugénio C

    2015-12-01

    Three different fermentation processes for the production of fructooligosaccharides (FOS) were evaluated and compared in terms of economic aspects and environmental impact. The processes included: submerged fermentation of sucrose solution by Aspergillus japonicus using free cells or using the cells immobilized in corn cobs, and solid-state fermentation (SSF) using coffee silverskin as support material and nutrient source. The scale-up was designed using data obtained at laboratory scale and considering an annual productivity goal of 200 t. SSF was the most attractive process in both economic and environmental aspects since it is able to generate FOS with higher annual productivity (232.6 t) and purity (98.6%) than the other processes; reaches the highest annual profit (6.55 M€); presents the lowest payback time (2.27 years); and is more favourable environmentally causing a lower carbon footprint (0.728 kg/kg, expressed in mass of CO2 equivalent per mass of FOS) and the lowest wastewater generation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Heating facilities: Klamath Lutheran Church, Klamath Falls, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-08-01

    The Klamath Lutheran Church is a masonry structure with cathedral ceiling containing approximately 5800 sq ft of floor area. This building is currently heated by two duct furnaces and a unit heater all of which are gas fired. An Educational Wing of approximately 6300 sq ft was added in 1958. This building, containing 2 assembly rooms and a number of classrooms is of uninsulated frame construction, with extensive glass area. A gas-fired boiler supplying finned tube radiators currently heats this wing. Four specific options for displacing all or part of the heating duty with geothermal were examined. These options are:more » case 1 - drilling a production and injection well on the property and using the resultant hot water (180/sup 0/F) to heat the entire facility; case 3 - using effluent from the Klamath Union High School to heat the entire facility; no well drilling required; case 2 - using effluent from the Klamath Union High School to heat only the church building; the present gas boiler would heat the Educational Wing; and case 4 - drilling a production and injection well on the property and using the resulting water (70/sup 0/F) to supply a water-to-water heat pump. Of the four cases examined, case 3 (heating of both the church building and educational wing with effluent from the Klamath Union High School) seems to offer the greatest potential and earliest simple payback period. (MHR)« less

  20. High Performance Slab-on-Grade Foundation Insulation Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldberg, Louise F.; Mosiman, Garrett E.

    ?A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 % for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.« less

  1. Building America Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits, Madison, Wisconsin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulationmore » at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated). The optimum insulation strategy was applied to single and multi-family residential buildings in climate zone 4 - 7. The highest site energy savings of 5% was realized for a single family home in Duluth, MN, and the lowest savings of 1.4 percent for a 4-unit townhouse in Richmond, VA. SOG foundation insulation retrofit simple paybacks ranged from 18 to 47 years. There are other benefits of SOG foundation insulation resulting from the increase in the slab surface temperatures. These include increased occupant thermal comfort, and a decrease in slab surface condensation particularly around the slab perimeter.« less

  2. Annual Energy Savings and Thermal Comfort of Autonomously Heated and Cooled Office Chairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, Scott; Booten, Chuck; Robertson, Joseph

    Energy use in offices buildings is largely driven by air conditioning demands. But the optimal temperature is not the same for all building occupants, leading to the infamous thermostat war. And many occupants have independently overcome building comfort weaknesses with their own space heaters or fans. NREL tested is a customized office chair that automatically heats and cools the occupant along the seat and chair back according to the occupants' personal preferences. This product is shown to deliver markedly better comfort at room temperatures well above typical office cooling setpoints. Experimental subjects reported satisfaction in these elevated air temperatures, partlymore » because the chair's cooling effect was tuned to their own individual needs. Simulation of the chair in office buildings around the U.S. shows that energy can be saved everywhere, with impacts varying due to the climate. Total building HVAC energy savings exceeded 10% in hot-dry climate zones. Due to high product cost, simple payback for the chair we studied is beyond the expected chair life. We then understood the need to establish cost-performance targets for comfort delivery packages. NREL derived several hypothetical energy/cost/comfort targets for personal comfort product systems. In some climate regions around the U.S., these show the potential for office building HVAC energy savings in excess of 20%. This report documents this research, providing an overview of the research team's methods and results while also identifying areas for future research building upon the findings.« less

  3. Thermal treatment of medical waste in a rotary kiln.

    PubMed

    Bujak, J

    2015-10-01

    This paper presents the results of a study of an experimental system with thermal treatment (incineration) of medical waste conducted at a large complex of hospital facilities. The studies were conducted for a period of one month. The processing system was analysed in terms of the energy, environmental and economic aspects. A rotary combustion chamber was designed and built with the strictly assumed length to inner diameter ratio of 4:1. In terms of energy, the temperature distribution was tested in the rotary kiln, secondary combustion (afterburner) chamber and heat recovery system. Calorific value of medical waste was 25.0 MJ/kg and the thermal efficiency of the entire system equalled 66.8%. Next, measurements of the pollutant emissions into the atmosphere were performed. Due to the nature of the disposed waste, particular attention was paid to the one-minute average values of carbon oxide and volatile organic compounds as well as hydrochloride, hydrogen fluoride, sulphur dioxide and total dust. Maximum content of non-oxidized organic compounds in slag and bottom ash were also verified during the analyses. The best rotary speed for the combustion chamber was selected to obtain proper afterburning of the bottom slag. Total organic carbon content was 2.9%. The test results were used to determine the basic economic indicators of the test system for evaluating the profitability of its construction. Simple payback time (SPB) for capital expenditures on the implementation of the project was 4 years. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Hoeschele, E. Weitzel

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYSmore » model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  5. Feasibility Study Analysis of Establishing Archery Sports Special Place

    NASA Astrophysics Data System (ADS)

    Tarigan, U. P. P.; Mardhatillah, A.; Budiman, I.; Sembiring, A. C.; Ramadhan, M. S.

    2018-04-01

    This study essentially discusses the basic concepts related to the decision and process of selecting a sports archery business project in order to provide economic and social benefits over time. Archery sports is a sport that requires special skills, both accuracy, coordination mental training and improves the physical condition of the prime. In Medan, it's still a bit of practice archery, but many people love this sport. From the data collected, there are three locations where archery in the city of the field of the Sunggal Knights is located at Jl Tunggul Hitam no.1A, Kec. Medan Sunggal, Avros Educational Park Aval address at Avros Street No.60 Medan, and the Knights of Johor Archery Club which is located at Jl. The work of Darma Gg. Ujung Family, Medan Johor. Therefore a feasibility study was undertaken in establishing an archery sports place in the field. The aspects to be considered in making feasibility studies are market and marketing aspects, technical and equipment aspects, management aspects, legal aspects, economic and social aspects, and financial aspects. Financial analysis using own capital got Payback Period 3 years 5,8 months, Net Present Value Rp 11.684.026 and obtained Internal Rate of Return of 17%.

  6. The financial viability of an SOFC cogeneration system in single-family dwellings

    NASA Astrophysics Data System (ADS)

    Alanne, Kari; Saari, Arto; Ugursal, V. Ismet; Good, Joel

    In the near future, fuel cell-based residential micro-CHP systems will compete with traditional methods of energy supply. A micro-CHP system may be considered viable if its incremental capital cost compared to its competitors equals to cumulated savings during a given period of time. A simplified model is developed in this study to estimate the operation of a residential solid oxide fuel cell (SOFC) system. A comparative assessment of the SOFC system vis-à-vis heating systems based on gas, oil and electricity is conducted using the simplified model for a single-family house located in Ottawa and Vancouver. The energy consumption of the house is estimated using the HOT2000 building simulation program. A financial analysis is carried out to evaluate the sensitivity of the maximum allowable capital cost with respect to system sizing, acceptable payback period, energy price and the electricity buyback strategy of an energy utility. Based on the financial analysis, small (1-2 kW e) SOFC systems seem to be feasible in the considered case. The present study shows also that an SOFC system is especially an alternative to heating systems based on oil and electrical furnaces.

  7. Techno-economic and profitability analysis of food waste biorefineries at European level.

    PubMed

    Cristóbal, Jorge; Caldeira, Carla; Corrado, Sara; Sala, Serenella

    2018-07-01

    Food waste represents a potential source to produce value-added materials replacing the use of virgin ones. However, the use of food waste as feedstock in biorefineries is still at an early stage of development and studies assessing its economic viability at large scale are lacking in the literature. This paper presents a techno-economic and profitability analysis of four food waste biorefineries that use wastes from tomato, potato, orange, and olive processing as feedstock. The study includes the assessment of potentially available quantities of those waste flows in Europe. Due to the low technology readiness level of this kind of biorefineries, a screening methodology to estimate the investment and manufacturing costs as well as two profitability ratios (the return on investment and the payback time) was adopted. Results show that not all the waste feedstocks have the same potential. The most profitable options are those related to implementing fewer plants, namely concentrating the production and capitalising on economies of scale while being at risk of increasing externalities, e.g. due to logistics of the feedstocks. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Analysis of wallboard containing a phase change material

    NASA Astrophysics Data System (ADS)

    Tomlinson, J. J.; Heberle, D. P.

    Phase change materials (PCMs) used on the interior of buildings hold the promise for improved thermal performance by reducing the energy requirements for space conditioning and by improving thermal comfort by reducing temperature swings inside the building. Efforts are underway to develop a gypsum wallboard containing a hydrocarbon PCM. With a phase change temperature in the room temperature range, the PCM wallboard adds substantially to the thermal mass of the building while serving the same architectural function as conventional wallboard. To determine the thermal and economic performance of this PCM wallboard, the Transient Systems Simulation Program (TRNSYS) was modified to accommodate walls that are covered with PCM plasterboard, and to apportion the direct beam solar radiation to interior surfaces of a building. The modified code was used to simulate the performance of conventional and direct-gain passive solar residential-sized buildings with and without PCM wallboard. Space heating energy savings were determined as a function of PCM wallboard characteristics. Thermal comfort improvements in buildings containing the PCM were qualified in terms of energy savings. The report concludes with a present worth economic analysis of these energy savings and arrives at system costs and economic payback based on current costs of PCMs under study for the wallboard application.

  9. Social Security reform: evaluating current proposals. Latest results of the EBRI-SSASIM2 policy simulation model.

    PubMed

    Copeland, C; VanDerhei, J; Salisbury, D L

    1999-06-01

    The present Social Security program has been shown to be financially unsustainable in the future without modification to the current program. The purpose of this Issue Brief, EBRI's fourth in a series on Social Security reform, is threefold: to illustrate new features of the EBRI-SSASIM2 policy simulation model not available in earlier EBRI publications, to expand quantitative analysis to specific proposals, and to evaluate the uncertainty involved in proposals that rely on equity investment. This analysis compares the Gregg/Breaux-Kolbe/Stenholm (GB-KS) and Moynihan/Kerrey proposals with three generic or "traditional" reforms: increasing taxes, reducing benefits, and/or increasing the retirement age. Both proposals would create individual accounts by "carving out" funds from current Social Security payroll taxes. This analysis also examines other proposed changes that would "add on" to existing Social Security funds through the use of general revenue transfers and/or investment in the equities market. President Clinton has proposed a general revenue transfer and the collective investment of some of the OASDI trust fund assets in equities. Reps. Archer and Shaw have proposed a general revenue tax credit to establish individual accounts that would be invested partially in the equities markets. When comparing Social Security reform proposals that would specifically alter benefit levels, the Moynihan/Kerrey bill compares quite favorably with the other proposals in both benefit levels and payback ratios, when individuals elect to use the individual account option. In contrast, the GB-KS bills do not compare quite as favorably for their benefit levels, but do compare favorably in terms of payback ratios. An important comparison in these bills is the administrative costs of managing the individual accounts, since benefits can be lowered by up to 23 percent when going from the assumed low to high administrative costs. Moreover, allowing individuals to decide whether to save the 2 percent of their OASDI taxable income or to receive higher takehome pay, as would be allowed in Moynihan/Kerrey, could lead to substantial differences in ultimate retirement income. Allowing for individual investment choices and using actual 401(k) participant allocation data, as opposed to an assumed average allocation for everyone, results in substantial differences in account balances. The Archer/Shaw approach mandates a 60 percent/40 percent equity/bond split specifically to avoid the variations in returns that arise from individual investment allocation decisions. Although there are greater chances for higher returns for equity investment in the president's proposal, there are also greater chances for worse outcomes. This is also true for other reforms that would invest Social Security assets in equities.

  10. Financial modeling in medicine: cash flow, basic metrics, the time value of money, discount rates, and internal rate of return.

    PubMed

    Lexa, Frank James; Berlin, Jonathan W

    2005-03-01

    In this article, the authors cover tools for financial modeling. Commonly used time lines and cash flow diagrams are discussed. Commonly used but limited terms such as payback and breakeven are introduced. The important topics of the time value of money and discount rates are introduced to lay the foundation for their use in modeling and in more advanced metrics such as the internal rate of return. Finally, the authors broach the more sophisticated topic of net present value.

  11. JT8D engine performance retention

    NASA Technical Reports Server (NTRS)

    James, A. D.; Weisel, D. R.

    1981-01-01

    The attractive performance retention characteristics of the JT8D engine are described. Because of its moderate bypass ratio and turbine temperature, and stiff structural design, the performance retention versus flight cycles of the JT8D engine sets a standard that is difficult for other engines to equal. In addition, the significant benefits of refurbishment of the JT8D engine are presented. Cold section refurbishment offers thrust specific fuel consumption improvements of up to 2 percent and payback in less than a year, making a very attractive investment option for the airlines.

  12. Economical Development of Complex Computer Systems

    DTIC Science & Technology

    1992-08-15

    margins typically encountered in the ........ beginning of a product’s life cycle, and shorten the payback period.4 leS D ~~~~LC~~~ Jr4.tt L~s.c...recurring, and other related costsincurred, or estimated to be incurr in the design, research and development (R& D ), investment, operation, maintenance...on the basis of cost. D E C R ’Item I E Incorporatento A-ml S .... .. EF D Y ..... S F R Technology& : Recnser 0 N P T Item N A -- Y E -- B N ’’A D

  13. Progress of solar technology and potential farm uses

    NASA Astrophysics Data System (ADS)

    Heid, W. G., Jr.; Trotter, W. K.

    1982-09-01

    The efficient use of solar energy on farms for space heating and cooling of livestock buildings, drying crops, and heating farm homes is discussed. Low cost, homemade solar collectors, having multiple uses and a payback of less than 5 years, are the most popular systems. In contrast, most commercially produced systems are still too expensive for agricultural uses, partly because they fail to qualify for tax credits as large as those allowed for residential uses. The solar industry has shown little interest in marketing the low cost technologies specifically developed for agriculture.

  14. Cost of capital to the hospital sector.

    PubMed

    Sloan, F A; Valvona, J; Hassan, M; Morrisey, M A

    1988-03-01

    This paper provides estimates of the cost of equity and debt capital to for-profit and non-profit hospitals in the U.S. for the years 1972-83. The cost of equity is estimated using, alternatively, the Capital Asset Pricing Model and Arbitrage Pricing Theory. We find that the cost of equity capital, using either model, substantially exceeded anticipated inflation. The cost of debt capital was much lower. Accounting for the corporate tax shield on debt and capital paybacks by cost-based insurers lowered the net cost of capital to hospitals.

  15. Business Case for a Micro-Combined Heat and Power Fuel Cell System in Commercial Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brooks, Kriston P.; Makhmalbaf, Atefe; Anderson, David M.

    2013-10-30

    Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and hot water with greater efficiency and lower emissions than alternative sources. These systems can be used either as baseload, grid-connected, or as off-the-grid power sources. This report presents a business case for CHP-FCSs in the range of 5 to 50 kWe. Systems in this power range are considered micro-CHP-FCS. For this particular business case, commercial applications rather than residential or industrial are targeted. To understand the benefits of implementing a micro-CHP-FCS, the characteristics that determine their competitive advantage must first be identified. Locations with high electricity pricesmore » and low natural gas prices are ideal locations for micro-CHP-FCSs. Fortunately, these high spark spread locations are generally in the northeastern area of the United States and California where government incentives are already in place to offset the current high cost of the micro-CHP-FCSs. As a result of the inherently high efficiency of a fuel cell and their ability to use the waste heat that is generated as a CHP, they have higher efficiency. This results in lower fuel costs than comparable alternative small-scale power systems (e.g., microturbines and reciprocating engines). A variety of markets should consider micro-CHP-FCSs including those that require both heat and baseload electricity throughout the year. In addition, the reliable power of micro-CHP-FCSs could be beneficial to markets where electrical outages are especially frequent or costly. Greenhouse gas emission levels from micro-CHP-FCSs are 69 percent lower, and the human health costs are 99.9 percent lower, than those attributed to conventional coal-fired power plants. As a result, FCSs can allow a company to advertise as environmentally conscious and provide a bottom-line sales advantage. As a new technology in the early stages of adoption, micro-CHP-FCSs are currently more expensive than alternative technologies. As the technology gains a foothold in its target markets and demand increases, the costs will decline in response to improved manufacturing efficiencies, similar to trends seen with other technologies. Transparency Market Research forecasts suggest that the CHP-FCS market will grow at a compound annual growth rate of greater than 27 percent over the next 5 years. These production level increases, coupled with the expected low price of natural gas, indicate the economic payback period will move to less than 5 years over the course of the next 5 years. To better understand the benefits of micro-CHP-FCSs, The U.S. Department of Energy worked with ClearEdge Power to install fifteen 5-kWe fuel cells in the commercial markets of California and Oregon. Pacific Northwest National Laboratory is evaluating these systems in terms of economics, operations, and their environmental impact in real-world applications. As expected, the economic analysis has indicated that the high capital cost of the micro-CHP-FCSs results in a longer payback period than typically is acceptable for all but early-adopter market segments. However, a payback period of less than 3 years may be expected as increased production brings system cost down, and CHP incentives are maintained or improved.« less

  16. Optimized MBR for greywater reuse systems in hotel facilities.

    PubMed

    Atanasova, Natasa; Dalmau, Montserrat; Comas, Joaquim; Poch, Manel; Rodriguez-Roda, Ignasi; Buttiglieri, Gianluigi

    2017-05-15

    Greywater is an important alternative water source, particularly in semi-arid, touristic areas, where the biggest water demand is usually in the dry period. By using this source wisely, tourist facilities can substantially reduce the pressure to scarce water resources. In densely urbanized touristic areas, where space has high value, compact solutions such as MBR based greywater reuse systems appear very appropriate. This research focuses on technical and economical evaluation of such solution by implementing a pilot MBR to a hotel with separated grey water. The pilot was operated for 6 months, with thorough characterisation of the GW performed, its operation was monitored and its energy consumption was optimized by applying a control system for the air scour. Based on the pilot operation a design and economic model was set to estimate the feasibility (CAPEX, OPEX, payback period of investment) of appropriate scales of MBR based GW systems, including separation of GW, MBR technology, clean water storage and disinfection. The model takes into account water and energy prices in Spain and a planning period of 20 years. The results demonstrated an excellent performance in terms of effluent quality, while the energy demand for air-scour was reduced by up to 35.2%, compared to the manufacturer recommendations. Economical evaluation of the entire MBR based GW reuse system shows its feasibility for sizes already at 5 m 3 /day (60 PE). The payback period of the investment for hotels like the demonstration hotel, treating 30 m 3 /day is 3 years. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. The Relationship Between Structural Game Characteristics and Gambling Behavior: A Population-Level Study.

    PubMed

    Leino, Tony; Torsheim, Torbjørn; Blaszczynski, Alex; Griffiths, Mark; Mentzoni, Rune; Pallesen, Ståle; Molde, Helge

    2015-12-01

    The aim of this study was to examine the relationship between the structural characteristics and gambling behavior among video lottery terminal (VLT) gamblers. The study was ecological valid, because the data consisted of actual gambling behavior registered in the participants natural gambling environment without intrusion by researchers. Online behavioral tracking data from Multix, an eight game video lottery terminal, were supplied by Norsk-Tipping (the state owned gambling company in Norway). The sample comprised the entire population of Multix gamblers (N = 31,109) who had gambled in January 2010. The individual number of bets made across games was defined as the dependent variable, reward characteristics of a game (i.e., payback percentage, hit frequency, size of winnings and size of jackpot) and bet characteristics of a game (i.e., range of betting options and availability of advanced betting options) served as the independent variables. Control variables were age and gender. Two separate cross-classified multilevel random intercepts models were used to analyze the relationship between bets made, reward characteristics and bet characteristics, where the number of bets was nested within both individuals and within games. The results show that the number of bets is positively associated with payback percentage, hit frequency, being female and age, and negatively associated with size of wins and range of available betting options. In summary, the results show that the reward characteristics and betting options explained 27% and 15% of the variance in the number of bets made, respectively. It is concluded that structural game characteristics affect gambling behavior. Implications of responsible gambling are discussed.

  18. Technical support document: Energy conservation standards for consumer products: Dishwashers, clothes washers, and clothes dryers including: Environmental impacts; regulatory impact analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-12-01

    The Energy Policy and Conservation Act as amended (P.L. 94-163), establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. This Technical Support Document presents the methodology, data and results from the analysis of the energy and economic impacts of standards on dishwashers, clothes washers, and clothes dryers. The economic impact analysis is performed in five major areas: An Engineering Analysis, which establishes technical feasibility and product attributesmore » including costs of design options to improve appliance efficiency. A Consumer Analysis at two levels: national aggregate impacts, and impacts on individuals. The national aggregate impacts include forecasts of appliance sales, efficiencies, energy use, and consumer expenditures. The individual impacts are analyzed by Life-Cycle Cost (LCC), Payback Periods, and Cost of Conserved Energy (CCE), which evaluate the savings in operating expenses relative to increases in purchase price; A Manufacturer Analysis, which provides an estimate of manufacturers' response to the proposed standards. Their response is quantified by changes in several measures of financial performance for a firm. An Industry Impact Analysis shows financial and competitive impacts on the appliance industry. A Utility Analysis that measures the impacts of the altered energy-consumption patterns on electric utilities. A Environmental Effects analysis, which estimates changes in emissions of carbon dioxide, sulfur oxides, and nitrogen oxides, due to reduced energy consumption in the home and at the power plant. A Regulatory Impact Analysis collects the results of all the analyses into the net benefits and costs from a national perspective. 47 figs., 171 tabs. (JF)« less

  19. Multifamily Heat Pump Water Heater Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Weitzel, E.

    2017-03-03

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. Themore » TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  20. Multifamily Heat Pump Water Heater Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Weitzel, E.

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. Themore » TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  1. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYSmore » model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  2. Experimental and feasibility assessment of biogas production by anaerobic digestion of fruit and vegetable waste from Joburg Market.

    PubMed

    Masebinu, S O; Akinlabi, E T; Muzenda, E; Aboyade, A O; Mbohwa, C

    2018-05-01

    Substrate-induced instability of anaerobic digestion from fruit and vegetable waste (FVW) results in low biogas yield. In this study, substrate management through fruit to vegetable mix ratio in a two-stage semi-continuous digester was investigated as a pathway for optimality of yield. The experiment conducted over 105 days with 62.52 kg of FVWs sourced from Joburg Market, South Africa showed that a stable process was achieved at a fruit to vegetable waste mix ratio of 2.2:2.8. At this ratio, optimal organic loading rate ranged between 2.68 and 2.97 kg VS/m 3 -d which resulted in a specific biogas yield of 0.87 Nm 3 /kg VS with 57.58% methane on average. The results of the experimental study were used as a feasibility assessment for a full-scale 45 tonnes/d plant for Joburg Market considering three energy pathways. The plant will produce 1,605,455 Nm 3 /y of biogas with the potential for offsetting 15.2% of the Joburg Market energy demand. Conversion of all biogas to biomethane was the most economically attractive energy pathway with a net present value of $2,428,021, an internal rate of return of 16.90% and a simple payback period of 6.17 years. This route avoided the greenhouse gas emission of 12,393 tonnes CO 2 , eq. The study shows that the anaerobic digestion of FVWs as sole substrate is possible with financial and environmental attractiveness. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Baker-Barry Tunnel Lighting: Evaluation of a Potential GATEWAY Demonstrations Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuenge, Jason R.

    2011-06-28

    The U.S. Department of Energy is evaluating the Baker-Barry Tunnel as a potential GATEWAY Demonstrations project for deployment of solid-state lighting (SSL) technology. The National Park Service views this project as a possible proving ground and template for implementation of light-emitting diode (LED) luminaires in other tunnels, thereby expanding the estimated 40% energy savings from 132 MWh/yr to a much larger figure nationally. Most of the energy savings in this application is attributable to the instant-restrike capability of LED products and to their high tolerance for frequent on/off switching, used here to separately control either end of the tunnel duringmore » daytime hours. Some LED luminaires rival or outperform their high-intensity discharge (HID) counterparts in terms of efficacy, but options are limited, and smaller lumen packages preclude true one-for-one equivalence. However, LED products continue to improve in efficacy and affordability at a rate unmatched by other light source technologies; the estimated simple payback period of eight years (excluding installation costs and maintenance savings) can be expected to improve with time. The proposed revisions to the existing high-pressure sodium (HPS) lighting system would require slightly increased controls complexity and significantly increased luminaire types and quantities. In exchange, substantial annual savings (from reduced maintenance and energy use) would be complemented by improved quantity and quality of illumination. Although advanced lighting controls could offer additional savings, it is unclear whether such a system would prove cost-effective; this topic may be explored in future work.« less

  4. Design and Analysis of Photovoltaic (PV) Power Plant at Different Locations in Malaysia

    NASA Astrophysics Data System (ADS)

    Islam, M. A.; Hasanuzzaman, M.; Rahim, N. A.

    2018-05-01

    Power generation from sun oriented vitality through a photovoltaic (PV) system is ended up prevalent over the world due to clean innovation. Geographical location of Malaysia is very favorable for PV power generation system. The Malaysian government has also taken different steps to increase the use of solar energy especially by emphasizing on building integrated PV (BIPV) system. Comparative study on the feasibility of BIPV installation at the different location of Malaysia is rarely found. On the other hand, solar cell temperature has a negative impact on the electricity generation. So in this study cost effectiveness and initial investment cost of building integrated grid connected solar PV power plant in different regions of Malaysia have been carried. The effect of PV solar cell temperature on the payback period (PBP) is also investigated. Highest PBP is 12.38 years at Selangor and lowest PBP is 9.70 years at Sabah (Kota Kinabalu). Solar cell temperature significantly increases the PBP of PV plant and highest 14.64% and lowest 13.20% raise of PBP are encountered at Penang and Sarawak respectively.

  5. Energy balance, greenhouse gas emissions, and profitability of thermobarical pretreatment of cattle waste in anaerobic digestion.

    PubMed

    Budde, Jörn; Prochnow, Annette; Plöchl, Matthias; Suárez Quiñones, Teresa; Heiermann, Monika

    2016-03-01

    In this study modeled full scale application of thermobarical hydrolysis of less degradable feedstock for biomethanation was assessed in terms of energy balance, greenhouse gas emissions, and economy. Data were provided whether the substitution of maize silage as feedstock for biogas production by pretreated cattle wastes is beneficial in full-scale application or not. A model device for thermobarical treatment has been suggested for and theoretically integrated in a biogas plant. The assessment considered the replacement of maize silage as feedstock with liquid and/or solid cattle waste (feces, litter, and feed residues from animal husbandry of high-performance dairy cattle, dry cows, and heifers). The integration of thermobarical pretreatment is beneficial for raw material with high contents of organic dry matter and ligno-cellulose: Solid cattle waste revealed very short payback times, e.g. 9 months for energy, 3 months for greenhouse gases, and 3 years 3 months for economic amortization, whereas, in contrast, liquid cattle waste did not perform positive replacement effects in this analysis. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. A quality-of-life-oriented endpoint for comparing therapies.

    PubMed

    Gelber, R D; Gelman, R S; Goldhirsch, A

    1989-09-01

    An endpoint, time without symptoms of disease and toxicity of treatment (TWiST), is defined to provide a single measure of length and quality of survival. Time with subjective side effects of treatment and time with unpleasant symptoms of disease are subtracted from overall survival time to calculate TWiST for each patient. The purpose of this paper is to describe the construction of this endpoint, and to elaborate on its interpretation for patient care decision-making. Estimating the distribution of TWiST using actuarial methods is shown by simulation studies to be biased as a result of induced dependency between TWiST and its censoring distribution. Considering the distribution of TWiST accumulated within a specified time from start of therapy, L, allows one to reduce this bias by substituting estimated TWiST for censored values and provides a method to evaluate the "payback" period for early toxic effects. Quantile distance plots provide graphical representations for treatment comparisons. The analysis of Ludwig Trial III evaluating toxic adjuvant therapies versus a no-treatment control group for postmenopausal women with node-positive breast cancer illustrates the methodology.

  7. Prospects for development of hydrocarbon raw materials resources reproduction

    NASA Astrophysics Data System (ADS)

    Vertakova, Y. V.; Babich, T. N.; Polozhentseva, Y. S.; Zvyagintsev, G. L.

    2017-10-01

    The article presents data on the influence of factors in the field of innovative technology of thermocatalytic depolymerization of solid household wastes (SHW) on the efficiency and prospects for the development of technogenic hydrocarbon raw materials resource reproduction. Process thermodynamics, reactions kinetics, the mechanism of thermolysis of secondary polymers in organic solvents have been studied by means of laboratory experiments. It is shown that different morphological groups of wastes dissolve practically at the same rate at temperatures of 250-310°C. A homogeneous product is formed in the liquid phase; the spread of values for the elements lies in the interval of 1.5-4.5 %; technological requirements of the stages of formation of boiler fuels are satisfied. Using the principles of patent analysis, new techniques of processing household waste components are proposed. The basics of energy-efficient and energy-saving processes of technogenic hydrocarbon raw materials resource reproduction have been laid. The possibility of increasing the production payback and intensification is shown. Ecological and demographic safety for population and technical and economic benefits from SHW processing are achieved.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D.; Munk, Jeffrey D.; Gehl, Anthony C.

    The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming frommore » reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.« less

  9. Solar energy for electricity and fuels.

    PubMed

    Inganäs, Olle; Sundström, Villy

    2016-01-01

    Solar energy conversion into electricity by photovoltaic modules is now a mature technology. We discuss the need for materials and device developments using conventional silicon and other materials, pointing to the need to use scalable materials and to reduce the energy payback time. Storage of solar energy can be achieved using the energy of light to produce a fuel. We discuss how this can be achieved in a direct process mimicking the photosynthetic processes, using synthetic organic, inorganic, or hybrid materials for light collection and catalysis. We also briefly discuss challenges and needs for large-scale implementation of direct solar fuel technologies.

  10. Impact of composites on future transport aircraft

    NASA Technical Reports Server (NTRS)

    Kinder, Robert H.

    1993-01-01

    In the current environment, new technology must be cost-effective in addition to improving operability. Various approaches have been used to determine the 'hurdle' or 'breakthrough' return that must be achieved to gain customer commitment for a new product or aircraft, or in this case, a new application of the technology. These approaches include return-on-investment, payback period, and addition to net worth. An easily understood figure-of-merit and one used by our airline customers is improvement in direct operating cost per seat-mile. Any new technology must buy its way onto the aircraft through reduction in direct operating cost (DOC).

  11. Naftokrak-Naftdbudowa & MPEC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szewczyk, T.; Mazur, J.

    1995-12-31

    Polish graded coal is being burned on existing stoker boilers at MPEC`s Balicka plant, using Control Techtronics microprocess-based system. Pictures were shown of the equipment controlling three hot water WR-10 boilers, and (two) steam 22.5 boilers. The results of this installation include; 85% reduction in stack particulate emission, 25% increase in boiler energy efficiency, 65% reduction in fan electrical energy, achieving {open_quotes}ultra low fire{close_quotes} which provides 3 or 4 to 1 turndown, versus 2 to 1, for substantially reduced fuel use at low heating requirements, and 2 to 3 years payback on invested capital.

  12. Managing loss adjustment expenses: strategies for health care risk managers.

    PubMed

    Quinley, K M

    1991-01-01

    Like most businesses, adjusting companies are not charitable organizations. They are entitled to a reasonable profit, which the risk manager should not begrudge. As a buyer of adjusting services, a risk manager with an inordinate obsession with slashing adjusting bills can destroy the goal of high-quality service. It is best for risk managers to pick and choose the areas for cutting adjusting expenses. To an extent, health care risk managers should view payment of high-quality adjusting services as an investment, with the payback being money saved by fighting fraudulent, exaggerated, and questionable claims.

  13. Processes and energy costs for mining lunar Helium-3

    NASA Technical Reports Server (NTRS)

    Sviatoslavsky, I. N.

    1988-01-01

    Preliminary investigations show that obtaining He-3 from the moon is technically feasible and economically viable. With the exception of beneficiation, the proposed procedures are state of the art. Mass of equipment needed from earth is of some concern, but resupply will eventually be ameliorated by the use of titanium from indigenous ilmenite. A complete energy payback from a D/He-3 fusion reactor utilizing lunar He-3 is approx. 80, providing ample incentive for commercial investment is forthcoming. Byproducts will be of great value to the resupply of a permanent lunar base and enhancement of space exploration.

  14. Analysis of wallboard containing a phase change material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomlinson, J.J.; Heberle, D.P.

    1990-01-01

    Phase change materials (PCMs) used on the interior of buildings hold the promise for improved thermal performance by reducing the energy requirements for space conditioning and by improving thermal comfort by reducing temperature swings inside the building. Efforts are underway to develop a gypsum wallboard containing a hydrocarbon PCM. With a phase change temperature in the room temperature range, the PCM wallboard adds substantially to the thermal mass of the building while serving the same architectural function as conventional wallboard. To determine the thermal and economic performance of this PCM wallboard, the Transient Systems Simulation Program (TRNSYS) was modified tomore » accommodate walls that are covered with PCM plasterboard, nd to apportion the direct beam solar radiation to interior surfaces of a building. The modified code was used to simulate the performance of conventional and direct-gain passive solar residential-sized buildings with and without PCM wallboard. Space heating energy savings were determined as a function of PCM wallboard characteristics. Thermal comfort improvements in buildings containing the PCM were qualified in terms of energy savings. The report concludes with a present worth economic analysis of these energy savings and arrives at system costs and economic payback based on current costs of PCMs under study for the wallboard application. 5 refs., 4 figs., 4 tabs.« less

  15. 4E analysis and multi objective optimization of a micro gas turbine and solid oxide fuel cell hybrid combined heat and power system

    NASA Astrophysics Data System (ADS)

    Sanaye, Sepehr; Katebi, Arash

    2014-02-01

    Energy, exergy, economic and environmental (4E) analysis and optimization of a hybrid solid oxide fuel cell and micro gas turbine (SOFC-MGT) system for use as combined generation of heat and power (CHP) is investigated in this paper. The hybrid system is modeled and performance related results are validated using available data in literature. Then a multi-objective optimization approach based on genetic algorithm is incorporated. Eight system design parameters are selected for the optimization procedure. System exergy efficiency and total cost rate (including capital or investment cost, operational cost and penalty cost of environmental emissions) are the two objectives. The effects of fuel unit cost, capital investment and system power output on optimum design parameters are also investigated. It is observed that the most sensitive and important design parameter in the hybrid system is fuel cell current density which has a significant effect on the balance between system cost and efficiency. The selected design point from the Pareto distribution of optimization results indicates a total system exergy efficiency of 60.7%, with estimated electrical energy cost 0.057 kW-1 h-1, and payback period of about 6.3 years for the investment.

  16. LCA as a Tool to Evaluate Green Infrastructure's Environmental Performance

    NASA Astrophysics Data System (ADS)

    Catalano De Sousa, M.; Erispaha, A.; Spatari, S.; Montalto, F.

    2011-12-01

    Decentralized approaches to managing urban stormwater through use of green infrastructure (GI) often lead to system-wide efficiency gains within the urban watershed's energy supply system. These efficiencies lead to direct greenhouse gas (GHG) emissions savings, and also restore some ecosystem functions within the urban landscape. We developed a consequential life cycle assessment (LCA) model to estimate the life cycle energy, global warming potential (GWP), and payback times for each if GI were applied within a select neighborhood in New York City. We applied the SIMAPRO LCA software and the economic input-output LCA (EIO-LCA) tool developed by Carnegie Mellon University. The results showed that for a new intersection installation highlighted in this study a conventional infrastructure construction would emit and use approximately 3 times more for both CO2 and energy than a design using GI. Two GI benefits were analyzed with regards to retrofitting the existing intersection. The first was related to the savings in energy and CO2 at the Waste Water Treatment Plant via runoff reduction accrued from GI use. The second benefit was related to the avoided environmental costs associated with an additional new grey infrastructure installation needed to prevent CSO in case of no GI implementation. The first benefit indicated a high payback time for a GI installation in terms of CO2 and energy demand (80 and 90 years respectively) and suggest a slow energy and carbon recovery time. However, concerning to the second benefit, GI proved to be a sustainable alternative considering the high CO2 releases (429 MTE) and energy demand (5.5 TJ) associated with a grey infrastructure construction.

  17. A systematic review of occupational safety and health business cases.

    PubMed

    Verbeek, Jos; Pulliainen, Marjo; Kankaanpää, Eila

    2009-12-01

    Business cases are commonly developed as means to rationalize investment. We systematically reviewed 26 reported cases on occupational safety and health (OSH) interventions to assess if health and productivity arguments make a good business case. To be included in the review, studies had to analyze the costs and benefits, including productivity, of an OSH intervention at the enterprise level. We searched Medline and Embase for studies and used Google search in addition. Two reviewers independently selected studies and extracted data. The intervention profitability was calculated in euros (euro in 2008) as the first year's benefits minus the total intervention costs per worker. The payback period was calculated as the intervention costs divided by the first year's benefits. We found three ex-ante and 23 ex-post cases. In 20 cases, the study design was a before-after comparison without a control group. Generally a 100% reduction of injuries or sickness absence was assumed. In two cases, productivity and quality increases were very large. The main benefit was avoided sick leave. Depreciation or discounting was applied only in a minority of cases. The intervention profitability was negative in seven studies, up to euro 500 per employee in 12 studies and more than euro 500 per employee in seven studies. The payback period was less than half a year for 19 studies. Only a few studies included sensitivity analyses. Few ex-ante business cases for management decisions on OSH are reported. Guidelines for reporting and evaluation are needed. Business cases need more sound assumptions on the effectiveness of interventions and should incorporate greater uncertainty into their design. Ex-post evaluation should be based preferably on study designs that control for trends at a time different from that of the intervention.

  18. The Impacts of Changes to Nevada's Net Metering Policy on the Financial Performance and Adoption of Distributed Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gagnon, Pieter; Sigrin, Ben; Gleason, Mike

    As the adoption of distributed photovoltaics (DPV) has continued to rapidly increase, a national conversation has begun about the efficacy of full-retail net metering as a means of achieving the diverse objectives of electricity pricing. This conversation has prompted studies that have primarily focused on the total costs and benefits of DPV. To compliment those studies, we here characterize the potential impacts of tariff design on the customer-economics and adoption of DPV, where recent changes in Nevada are taken as a case study. We show that an increase in fixed charges more strongly impacts the payback period of small systems,more » and a decrease in credit for exported electricity more strongly impacts the payback period of large systems. We project that these combined changes will reduce DPV adoption in Nevada; total capacity in 2030 was projected to reach up to 363 MW, with 226 MW having already been installed at the end of the second quarter of 2016. In contrast, if full retail net metering had continued, DPV capacity was projected to reach up to 1,280 MW at the end of 2030, which would account for an estimated 6.5% of the total sales of electricity by NV Energy at that time. We project that the DPV systems will decrease the gross revenue from bill collection by $48 million per year under the new tariffs, whereas the decrease in gross revenue could have reached $255 million per year if full retail net metering had been continued. Although these results are given in the context of Nevada, the trends shown are intended to help information similar upcoming decisions in other states.« less

  19. A Practical Application of Value of Information and Prospective Payback of Research to Prioritize Evaluative Research.

    PubMed

    Andronis, Lazaros; Billingham, Lucinda J; Bryan, Stirling; James, Nicholas D; Barton, Pelham M

    2016-04-01

    Efforts to ensure that funded research represents "value for money" have led to increasing calls for the use of analytic methods in research prioritization. A number of analytic approaches have been proposed to assist research funding decisions, the most prominent of which are value of information (VOI) and prospective payback of research (PPoR). Despite the increasing interest in the topic, there are insufficient VOI and PPoR applications on the same case study to contrast their methods and compare their outcomes. We undertook VOI and PPoR analyses to determine the value of conducting 2 proposed research programs. The application served as a vehicle for identifying differences and similarities between the methods, provided insight into the assumptions and practical requirements of undertaking prospective analyses for research prioritization, and highlighted areas for future research. VOI and PPoR were applied to case studies representing proposals for clinical trials in advanced non-small-cell lung cancer and prostate cancer. Decision models were built to synthesize the evidence available prior to the funding decision. VOI (expected value of perfect and sample information) and PPoR (PATHS model) analyses were undertaken using the developed models. VOI and PPoR results agreed in direction, suggesting that the proposed trials would be cost-effective investments. However, results differed in magnitude, largely due to the way each method conceptualizes the possible outcomes of further research and the implementation of research results in practice. Compared with VOI, PPoR is less complex but requires more assumptions. Although the approaches are not free from limitations, they can provide useful input for research funding decisions. © The Author(s) 2015.

  20. Lesson Learned from Technical and Economic Performance Assessment and Benefit Evaluation of CHP-FCS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makhmalbaf, Atefe; Brooks, Kriston P.; Srivastava, Viraj

    2014-08-22

    Recent efforts and interest in combined heat and power (CHP) have increased with the momentum provided by the federal government support for penetration of CHP systems. Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and utilize the heat normally wasted in power generation for useful heating or cooling with lower emissions compared to alternative sources. A recent study investigated the utilization of CHP-FCSs in the range of 5 to 50KWe in various commercial building types and geographic locations. Electricity, heating, and water heating demands were obtained from simulation of the U.S. Department of Energy (DOE) commercialmore » reference building models for various building types. Utility rates, cost of equipment, and system efficiency were used to examine economic payback in different scenarios. As a new technology in the early stages of adoption, CHP-FCSs are more expensive than alternative technologies, and the high capital cost of the CHP-FCSs results in a longer payback period than is typically acceptable for all but early-adopter market segments. However, the installation of these units as on-site power generators also provide several other benefits that make them attractive to building owners and operators. The business case for CHP-FCSs can be made more financially attractive through the provision of government incentives and when installed to support strategic infrastructure, such as military installations or data centers. The results presented in this paper intend to provide policy makers with information to define more customized incentives and tax credits based on a sample of building types and geographic locations in order to attract more business investment in this new technology.« less

  1. Optimal Renewable Energy Integration into Refinery with CO2 Emissions Consideration: An Economic Feasibility Study

    NASA Astrophysics Data System (ADS)

    Alnifro, M.; Taqvi, S. T.; Ahmad, M. S.; Bensaida, K.; Elkamel, A.

    2017-08-01

    With increasing global energy demand and declining energy return on energy invested (EROEI) of crude oil, global energy consumption by the O&G industry has increased drastically over the past few years. In addition, this energy increase has led to an increase GHG emissions, resulting in adverse environmental effects. On the other hand, electricity generation through renewable resources have become relatively cost competitive to fossil based energy sources in a much ‘cleaner’ way. In this study, renewable energy is integrated optimally into a refinery considering costs and CO2 emissions. Using Aspen HYSYS, a refinery in the Middle East was simulated to estimate the energy demand by different processing units. An LP problem was formulated based on existing solar energy systems and wind potential in the region. The multi-objective function, minimizing cost as well as CO2 emissions, was solved using GAMS to determine optimal energy distribution from each energy source to units within the refinery. Additionally, an economic feasibility study was carried out to determine the viability of renewable energy technology project implementation to overcome energy requirement of the refinery. Electricity generation through all renewable energy sources considered (i.e. solar PV, solar CSP and wind) were found feasible based on their low levelized cost of electricity (LCOE). The payback period for a Solar CSP project, with an annual capacity of about 411 GWh and a lifetime of 30 years, was found to be 10 years. In contrast, the payback period for Solar PV and Wind were calculated to be 7 and 6 years, respectively. This opens up possibilities for integrating renewables into the refining sector as well as optimizing multiple energy carrier systems within the crude oil industry

  2. Sustainability Efficiency Factor: Measuring Sustainability in Advanced Energy Systems through Exergy, Exergoeconomic, Life Cycle, and Economic Analyses

    NASA Astrophysics Data System (ADS)

    Boldon, Lauren

    The Encyclopedia of Life Support Systems defines sustainability or industrial ecology as "the wise use of resources through critical attention to policy, social, economic, technological, and ecological management of natural and human engineered capital so as to promote innovations that assure a higher degree of human needs fulfilment, or life support, across all regions of the world, while at the same time ensuring intergenerational equity" (Encyclopedia of Life Support Systems 1998). Developing and integrating sustainable energy systems to meet growing energy demands is a daunting task. Although the technology to utilize renewable energies is well understood, there are limited locations which are ideally suited for renewable energy development. Even in areas with significant wind or solar availability, backup or redundant energy supplies are still required during periods of low renewable generation. This is precisely why it would be difficult to make the switch directly from fossil fuel to renewable energy generation. A transition period in which a base-load generation supports renewables is required, and nuclear energy suits this need well with its limited life cycle emissions and fuel price stability. Sustainability is achieved by balancing environmental, economic, and social considerations, such that energy is produced without detriment to future generations through loss of resources, harm to the environment, etcetera. In essence, the goal is to provide future generations with the same opportunities to produce energy that the current generation has. This research explores sustainability metrics as they apply to a small modular reactor (SMR)-hydrogen production plant coupled with wind energy and storage technologies to develop a new quantitative sustainability metric, the Sustainability Efficiency Factor (SEF), for comparison of energy systems. The SEF incorporates the three fundamental aspects of sustainability and provides SMR or nuclear hybrid energy system (NHES) reference case studies to (1) introduce sustainability metrics, such as life cycle assessment, (2) demonstrate the methods behind exergy and exergoeconomic analyses, (3) provide an economic analysis of the potential for SMR development from first-of-a-kind (FOAK) to nth-of-a-kind (NOAK), thereby illustrating possible cost reductions and deployment flexibility for SMRs over large conventional nuclear reactors, (4) assess the competitive potential for incorporation of storage and hydrogen production in NHES and in regulated and deregulated electricity markets, (5) compare an SMR-hydrogen production plant to a natural gas steam methane reforming plant using the SEF, and (6) identify and review the social considerations which would support future nuclear development domestically and abroad, such as public and political/regulatory needs and challenges. The Global Warming Potential (GWP) for the SMR (300 MWth)-wind (60 MWe)-high temperature steam electrolysis (200 tons Hydrogen per day) system was calculated as approximately 874 g CO2-equivalent as part of the life cycle assessment. This is 92.6% less than the GWP estimated for steam methane reforming production of hydrogen by Spath and Mann. The unit exergetic and exergoeconomic costs were determined for each flow within the NHES system as part of the exergy/exergoeconomic cost analyses. The unit exergetic cost is lower for components yielding more meaningful work like the one exiting the SMR with a unit exergetic cost of 1.075 MW/MW. In comparison, the flow exiting the turbine has a very high unit exergetic cost of 15.31, as most of the useful work was already removed through the turning of the generator/compressor shaft. In a similar manner, the high unit exergoeconomic cost of 12.45/MW*sec is observed for the return flow to the reactors, because there is very little exergy present. The first and second law efficiencies and the exergoeconomic factors were also determined over several cases. For the first or base SMR case, first and second law efficiencies of 81.5% and 93.3% were observed respectively. With an increase in reactor outlet temperature of only 20°C, both the SMR efficiencies increased, while the exergoeconomic factor decreased by 0.2%. As part of the SMR economic analysis, specific capital and total capital investment costs (TCIC) were determined in addition to conditional effects on the net present value (NPV), levelized cost of electricity (LCOE), and payback periods. For a 1260 MWe FOAK multi-module SMR site with 7 modules, the specific capital costs were 27-38% higher than that of a 1260 MWe single large reactor site. A NOAK site, on the other hand, may be 19% lower to 18% higher than the large reactor site, demonstrating that it may break even or be even more economical in average or favorable market conditions. The NOAK TCIC for single and multi-module SMR sites were determined to be 914-1,230 million and 660-967 million per module, respectively, reflecting the substantial savings incurred with sites designed for and deployed with multiple modules. For the same NOAK 7-unit multi-module site, the LCOE was calculated as 67-84/MWh, which is slightly less than that of the conventional large reactor LCOE of 89/MWh with a weighted average cost of capital of 10%, a 50%-50% share of debt and equity, and a corporate tax rate of 35%. The payback period for the SMR site, however, is 4 years longer. Construction delays were also analyzed to compare the SMR and large reactor sites, demonstrating the SMR NPV and LCOE are less sensitive to delays. For a 3 year delay, the SMR NPV decreased by 22%, while the large reactor NPV decreased by 34.1%. Similarly the SMR and large reactor LCOEs increased by 7.8% and 8.1%, respectively. An NHES case with hydrogen production and storage was performed, illustrating how the profit share of revenue is improved with the addition of hydrogen production. Although the costs are increased with the addition, 78% of the hydrogen revenue is profit, while only 50% of the electricity generation revenue is profit. A second NHES case study was analyzed to assess the NPV, LCOE, and payback differences in deregulated and regulated electricity markets. For a 60 year lifetime, Case C (with nuclear, wind, and hydrogen production) is economical in the deregulated market with an NPV of 66.3 million and a payback period of 10 years, but not in the regulated one with an NPV of approximately -115.3 million and a payback period of 11 years. With either market type, the plants levelized costs remain $82.82/MWh, which is still reasonable with respect to prior LCOE values determined for SMR and large reactor sites. Utilizing all the methodology and results obtained and presented in this thesis, the SEF may be calculated. The NHES SEF was determined to be 18.3% higher than that of natural gas steam methane reforming, illustrating a higher level of sustainability. The SEF quantitatively uses the exergoeconomic cost and irreversibilities obtained from the exergy analysis, the GWP obtained from the life cycle assessment and costs/fees associated with emissions and pollutants, and relevant economic data obtained from an economic analysis. This reflects the environmental, socio-political, and economic pillars of sustainability.

  3. Chapter 16: Retrocommissioning Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Tiessen, Alex

    Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.

  4. Alcoa World Alumina: Plant-Wide Assessment at Arkansas Operations Reveals More than$900,000 in Potential Annual Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2003-07-01

    The plant-wide energy-efficiency assessment performed in 2001 at the Alcoa World Alumina Arkansas Operations in Bauxite, Arkansas, identified seven opportunities to save energy and reduce costs. By implementing five of these improvements, the facility can save 15,100 million British thermal units per year in natural gas and 8.76 million kilowatt-hours per year in electricity. This translates into approximate annual savings of$925,300 in direct energy costs and non-fuel operating and maintenance costs. The required capital investment is estimated at$271,200. The average payback period for all five projects would be approximately 8 months.

  5. Alcoa World Alumina: Plant Wide Assessment at Arkansas Operation Reveals More than $900,000 in Potential Annual Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2003-07-01

    The plant-wide energy-efficiency assessment performed in 2001 at the Alcoa World Alumina Arkansas Operations in Bauxite, Arkansas, identified seven opportunities to save energy and reduce costs. By implementing five of these improvements, the facility can save 15,100 million British thermal units per year in natural gas and 8.76 million kilowatt-hours per year in electricity. This translates into approximate annual savings of $925,300 in direct energy costs and non-fuel operating and maintenance costs. The required capital investment is estimated at $271,200. The average payback period for all five projects would be approximately 8 months.

  6. Purchasing in a supply chain environment.

    PubMed

    Schorr, J E

    2000-08-01

    Why the interest in purchasing? In the typical company, material costs are 40% to 75% of the cost of goods sold, labor is 5% to 15%, and the balance is burden. The typical company has $4-$5 in purchased cost to $1 in labor. Most companies are implementing material requirements planning (MRP II) and enterprise resource planning systems to control the $1 in labor and have little expectation in the area of purchasing savings. Yet a dollar saved in purchasing goes directly to the bottom line. I ran a survey of 100 Class A users of MRP II; in all 100 of the companies, the biggest payback was in the area of purchasing.

  7. Natural Gas Use On Minibuses, Engaged In The Carriage Of Passengers And Baggage On The Regular Routes, As A Measure For Decrease In Harmful Environment Effects

    NASA Astrophysics Data System (ADS)

    Chikishev, E.; Chikisheva, A.; Anisimov, I.; Chainikov, D.

    2017-01-01

    The paper deals with an option of increase the compressed natural gas use as a motor fuel for diesel minibuses to reduce emissions of harmful substances with exhaust gases. In terms of the Russian company LTD "WTC Automobilist", carrying passengers and baggage on regular routes by minibuses, the calculation of the park's natural gas needs is promoted. A mini CNG RS with optimal performance is suggested. The approximate payback period of the natural gas equipment installation on all buses of company and introduction into service period of mini CNG RS are calculated.

  8. Particle tower technology applied to metallurgic plants and peak-time boosting of steam power plants

    NASA Astrophysics Data System (ADS)

    Amsbeck, Lars; Buck, Reiner; Prosin, Tobias

    2016-05-01

    Using solar tower technology with ceramic particles as heat transfer and storage medium to preheat scrap for induction furnaces in foundries provides solar generated heat to save electricity. With such a system an unsubsidized payback time of only 4 years is achieved for a 70000t/a foundry in Brazil. The same system can be also used for heat treatment of metals. If electricity is used to heat inert atmospheres a favorable economic performance is also achievable for the particle system. The storage in a particle system enables solar boosting to be restricted to only peak times, enabling an interesting business case opportunity.

  9. Personalized Vehicle Energy Efficiency & Range Predictor/MyGreenCar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SAXENA, SAMVEG

    MyGreenCar provides users with the ability to predict the range capabilities, fuel economy, and operating costs for any vehicle for their individual driving patterns. Users launce the MyGreeCar mobile app on their smartphones to collect their driving patterns over any duration (e.g. serval days, weeks, months, etc) using a phones's locational capabilities. Using vehicle powertrain models for any user-specified vehicle type, MyGreenCar, calculates the component-level energy and power interactions for the chosen vehicle to predict several important quantities, including: 1. For Evs: Alleviating range anxiety 2. Comparing fuel economy, operating costs, and payback time across models and types.

  10. Field Demonstration of Active Desiccant-Based Outdoor Air Preconditioning Systems, Final Report: Phase 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, J.

    2001-07-09

    This report summarizes an investigation of the performance of two active desiccant cooling systems that were installed as pilot systems in two locations--a college dormitory and a research laboratory--during the fall of 1999. The laboratory system was assembled in the field from commercially available Trane air-handling modules combined with a standard total energy recovery module and a customized active desiccant wheel, both produced by SEMCO. The dormitory system was a factory-built, integrated system produced by SEMCO that included both active desiccant and sensible-only recovery wheels, a direct-fired gas regeneration section, and a pre-piped Trane heat pump condensing section. Both systemsmore » were equipped with direct digital control systems, complete with full instrumentation and remote monitoring capabilities. This report includes detailed descriptions of these two systems, installation details, samples of actual performance, and estimations of the energy savings realized. These pilot sites represent a continuation of previous active desiccant product development research (Fischer, Hallstrom, and Sand 2000; Fischer 2000). Both systems performed as anticipated, were reliable, and required minimal maintenance. The dehumidification/total-energy-recovery hybrid approach was particularly effective in all respects. System performance showed remarkable improvement in latent load handling capability and operating efficiency compared with the original conventional cooling system and with the conventional system that remained in another, identical wing of the facility. The dehumidification capacity of the pilot systems was very high, the cost of operation was very low, and the system was cost-effective, offering a simple payback for these retrofit installations of approximately 5 to 6 years. Most important, the dormitory system resolved numerous indoor air quality problems in the dormitory by providing effective humidity control and increased, continuous ventilation air.« less

  11. Early action to reduce greenhouse gas emissions before the commitment period of the Kyoto protocol: advantages and disadvantages.

    PubMed

    Michaelowa, A; Rolfe, C

    2001-09-01

    Current "business as usual" projections suggest greenhouse gas emissions from industrialized nations will grow substantially over the next decade. However, if it comes into force, the Kyoto Protocol will require industrialized nations to reduce emissions to an average of 5% below 1990 levels in the 2008-2012 period. Taking early action to close this gap has a number of advantages. It reduces the risks of passing thresholds that trigger climate change "surprises." Early action also increases future generations' ability to choose greater levels of climate protection, and it leads to faster reductions of other pollutants. From an economic sense, early action is important because it allows shifts to less carbon-intensive technologies during the course of normal capital stock turnover. Moreover, many options for emission reduction have negative costs, and thus are economically worthwhile, because of paybacks in energy costs, healthcare costs, and other benefits. Finally, early emission reductions enhance the probability of successful ratification and lower the risk of noncompliance with the protocol. We discuss policy approaches for the period prior to 2008. Disadvantages of the current proposals for Credit for Early Action are the possibility of adverse selection due to problematic baseline calculation methods as well as the distributionary impacts of allocating a part of the emissions budget already before 2008. One simple policy without drawbacks is the so-called baseline protection, which removes the disincentive to early action due to the expectation that businesses may, in the future, receive emission rights in proportion to past emissions. It is particularly important to adopt policies that shift investment in long-lived capital stock towards less carbon-intensive technologies and to encourage innovation and technology development that will reduce future compliance costs.

  12. Refrigerated Warehouse Demand Response Strategy Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Doug; Castillo, Rafael; Larson, Kyle

    This guide summarizes demand response measures that can be implemented in refrigerated warehouses. In an appendix, it also addresses related energy efficiency opportunities. Reducing overall grid demand during peak periods and energy consumption has benefits for facility operators, grid operators, utility companies, and society. State wide demand response potential for the refrigerated warehouse sector in California is estimated to be over 22.1 Megawatts. Two categories of demand response strategies are described in this guide: load shifting and load shedding. Load shifting can be accomplished via pre-cooling, capacity limiting, and battery charger load management. Load shedding can be achieved by lightingmore » reduction, demand defrost and defrost termination, infiltration reduction, and shutting down miscellaneous equipment. Estimation of the costs and benefits of demand response participation yields simple payback periods of 2-4 years. To improve demand response performance, it’s suggested to install air curtains and another form of infiltration barrier, such as a rollup door, for the passageways. Further modifications to increase efficiency of the refrigeration unit are also analyzed. A larger condenser can maintain the minimum saturated condensing temperature (SCT) for more hours of the day. Lowering the SCT reduces the compressor lift, which results in an overall increase in refrigeration system capacity and energy efficiency. Another way of saving energy in refrigerated warehouses is eliminating the use of under-floor resistance heaters. A more energy efficient alternative to resistance heaters is to utilize the heat that is being rejected from the condenser through a heat exchanger. These energy efficiency measures improve efficiency either by reducing the required electric energy input for the refrigeration system, by helping to curtail the refrigeration load on the system, or by reducing both the load and required energy input.« less

  13. Performance of a large building rainwater harvesting system.

    PubMed

    Ward, S; Memon, F A; Butler, D

    2012-10-15

    Rainwater harvesting is increasingly becoming an integral part of the sustainable water management toolkit. Despite a plethora of studies modelling the feasibility of the utilisation of rainwater harvesting (RWH) systems in particular contexts, there remains a significant gap in knowledge in relation to detailed empirical assessments of performance. Domestic systems have been investigated to a limited degree in the literature, including in the UK, but there are few recent longitudinal studies of larger non-domestic systems. Additionally, there are few studies comparing estimated and actual performance. This paper presents the results of a longitudinal empirical performance assessment of a non-domestic RWH system located in an office building in the UK. Furthermore, it compares actual performance with the estimated performance based on two methods recommended by the British Standards Institute - the Intermediate (simple calculations) and Detailed (simulation-based) Approaches. Results highlight that the average measured water saving efficiency (amount of mains water saved) of the office-based RWH system was 87% across an 8-month period, due to the system being over-sized for the actual occupancy level. Consequently, a similar level of performance could have been achieved using a smaller-sized tank. Estimated cost savings resulted in capital payback periods of 11 and 6 years for the actual over-sized tank and the smaller optimised tank, respectively. However, more detailed cost data on maintenance and operation is required to perform whole life cost analyses. These findings indicate that office-scale RWH systems potentially offer significant water and cost savings. They also emphasise the importance of monitoring data and that a transition to the use of Detailed Approaches (particularly in the UK) is required to (a) minimise over-sizing of storage tanks and (b) build confidence in RWH system performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. The economic value of an investment in physiotherapy education: a net present value analysis.

    PubMed

    Rivers, George; Foo, Jonathan; Ilic, Dragan; Nicklen, Peter; Reeves, Scott; Walsh, Kieran; Maloney, Stephen

    2015-07-01

    What is the economic value for an individual to invest in physiotherapy undergraduate education in Australia? How is this affected by increased education costs or decreased wages? A cost-benefit analysis using a net present value (NPV) approach was conducted and reported in Australian dollars. In relation to physiotherapy education, the NPV represents future earnings as a physiotherapist minus the direct and indirect costs in obtaining the degree. Sensitivity analyses were conducted to consider varying levels of experience, public versus private sector, and domestic versus international student fees. Comparable calculations were made for educational investments in medicine and nursing/midwifery. Assuming an expected discount rate of 9.675%, investment in education by domestic students with approximately 34 years of average work experience yields a NPV estimated at $784,000 for public sector physiotherapists and $815,000 for private sector therapists. In relation to international students, the NPV results for an investment and career as a physiotherapist is estimated at $705,000 in the public sector and $736,000 in the private sector. With an approximate payback period of 4 years, coupled with strong and positive NPV values, physiotherapy education in Australia is a financially attractive prospect and a viable value proposition for those considering a career in this field. Copyright © 2015 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  15. Thermal Properties of Green Fuel Briquettes from Residue Corncobs Materials Mixed Macadamia Shell Charcoal Powder

    NASA Astrophysics Data System (ADS)

    Teeta, Suminya; Nachaisin, Mali; Wanish, Suchana

    2017-09-01

    The objective of this research was to produce green fuel briquettes from corncobs by adding macadamia shell charcoal powder. The study was sectioned into 3 parts: 1) Quality improvement of green fuel briquettes by adding macadamia; 2) Fuel property analysis based on ASTM standards and thermal fuel efficiency; and 3) Economics appropriateness in producing green fuel briquettes. This research produced green fuel briquettes using the ratio of corncobs weight and macadamia shell charcoal powder in 100:0 90:10 80:20 70:30 60:40 and 50:50 and pressing in the cold briquette machine. Fuel property analysis showed that green fuel briquettes at the ratio 50:50 produced maximum heating values at 21.06 Megajoule per kilogram and briquette density of 725.18 kilograms per cubic meter, but the percent of moisture content, volatile matter, ash, and fixed carbon were 10.09, 83.02, 2.17 and 4.72 respectively. The thermal efficiency of green fuel briquettes averaged 20.22%. Economics appropriateness was most effective where the ratio of corncobs weight to macadamia shell charcoal powder was at 50:50 which accounted for the cost per kilogram at 5.75 Baht. The net present value was at 1,791.25 Baht. Internal rate of return was at 8.62 and durations for a payback period of investment was at 1.9 years which was suitable for investment.

  16. Dynamic hybrid life cycle assessment of energy and carbon of multicrystalline silicon photovoltaic systems.

    PubMed

    Zhai, Pei; Williams, Eric D

    2010-10-15

    This paper advances the life cycle assessment (LCA) of photovoltaic systems by expanding the boundary of the included processes using hybrid LCA and accounting for the technology-driven dynamics of embodied energy and carbon emissions. Hybrid LCA is an extended method that combines bottom-up process-sum and top-down economic input-output (EIO) methods. In 2007, the embodied energy was 4354 MJ/m(2) and the energy payback time (EPBT) was 2.2 years for a multicrystalline silicon PV system under 1700 kWh/m(2)/yr of solar radiation. These results are higher than those of process-sum LCA by approximately 60%, indicating that processes excluded in process-sum LCA, such as transportation, are significant. Even though PV is a low-carbon technology, the difference between hybrid and process-sum results for 10% penetration of PV in the U.S. electrical grid is 0.13% of total current grid emissions. Extending LCA from the process-sum to hybrid analysis makes a significant difference. Dynamics are characterized through a retrospective analysis and future outlook for PV manufacturing from 2001 to 2011. During this decade, the embodied carbon fell substantially, from 60 g CO(2)/kWh in 2001 to 21 g/kWh in 2011, indicating that technological progress is realizing reductions in embodied environmental impacts as well as lower module price.

  17. Economical and financial analysis of lamb finishing fed with diets formulated according to the NRC (1985) and the NRC (2007).

    PubMed

    Rogério, Marcos Cláudio Pinheiro; de Castro, Eliane Minervina; Martins, Espedito Cezário; Monteiro, Jomar Patrício; Silva, Kleibe de Moraes; Cândido, Magno José Duarte; Gomes, Tereza Cristina Lacerda; Bloc, Antoine Francis Roux; de Vasconcelos, Angela Maria; Leite, Eneas Reis; Costa, Hélio Henrique Araújo

    2013-01-01

    This study compares both versions of the nutritional requirement system determined by the National Research Council (NRC) version 1985 (NRC85) and NRC version 2007 (NRC07), for finishing lambs in feedlots. Nineteen crossbred lambs were divided in four groups representing four experimental treatments: one diet according to NRC85 and three diets according to NRC07. The diets recommended by NRC07 considers crude protein intake relative to ruminal undegradable protein at 20, 40, and 60 % levels (NRC07/20, NRC07/40, and NRC07/60). Diets were composed of Brazilian semi-arid native grass silage, soybean meal, corn, annatto byproduct, and limestone. Purchases and sales of lambs were done according to average market prices in Brazil. The economic indicators considered pointed that all treatments were viable but NRC07/20 and NRC07/60 were more profitable with similar net present values (NPVs) and internal return rates (IRRs). NRC07/20 was the best option showing an IRR of 17.20 % and a payback period (PP) of 5.07 considering a fixed annual interest rate of 6 %. Sensitivity analysis considering a 10 % raise in variable costs showed negative NPVs, IRRs inferior to the opportunity cost rates adopted and PPs that exceeded the planning horizon of 7 years for both NRC85 and NRC07/40.

  18. Techno-economic assessment of Levulinic Acid Plant from Sorghum Bicolor in Indonesia

    NASA Astrophysics Data System (ADS)

    Gozan, M.; Ryan, B.; Krisnandi, Y.

    2018-04-01

    The increasing need of energy is one of the main energy security issues in Indonesia. Hence, alternative energy is needed. Levulinic acid (LA) is among chemical platform used in the synthesis for avariety of high-value materials, such as fuels and commodity chemicals. It is predicted that global LA market demand to reach 3.1 tons in 2016. This study examines industrial processdesign and economic analysis for LA production in Indonesia.Sorghum bicolor was used as feed because of its high cellulose, low lignin contents and availability in Indonesia. The conventional economic problem from biomass based production was diminished sincethe valuable waste from pretreatment processwas sold to otherindustry.This plant was recommended to be built in an industrial estate area in Jawa Timur (East Java) province. Results from simulation using SuperPro Designer 9.0 was used for the techno-economic assessment.The plant assessment showed that the minimum production capacity was 7.7 ton per day to achieve an internal rate of return (IRR) and payback period (PBP) values of 19.61% and 3.93 years, respectively. Sensitivity analysis showed that product selling price was the most predominant factor for IRR, NPV, PBP and ROI. Raw material and water had low effects on those economic parameters. These values indicated that LA plant was feasible to be built in Indonesia.

  19. Technical and Socioeconomic Potential of Biogas from Cassava Waste in Ghana.

    PubMed

    Kemausuor, Francis; Addo, Ahmad; Darkwah, Lawrence

    2015-01-01

    This study analyses technical potential and ex ante socioeconomic impacts of biogas production using cassava waste from agroprocessing plants. An analysis was performed for two biodigesters in two cassava processing communities in Ghana. The results showed that the two communities generate an excess of 4,500 tonnes of cassava peels per year. Using approximately 5% of the peels generated and livestock manure as inoculum can generate approximately 75,000 m(3) of gas with an estimated 60% methane content from two separate plants of capacities 500 m(3) and 300 m(3) in the two communities. If used internally as process fuel, the potential gas available could replace over 300 tonnes of firewood per year for cassava processing. The displacement of firewood with gas could have environmental, economic, and social benefits in creating sustainable development. With a 10 percent discount rate, an assumed 20-year biodigester will have a Net Present Value of approximately US$ 148,000, 7-year Payback Period, and an Internal Rate of Return of 18.7%. The project will create 10 full-time unskilled labour positions during the investment year and 4 positions during operation years.

  20. A meta-analytic review of life cycle assessment and flow analyses studies of palm oil biodiesel.

    PubMed

    Manik, Yosef; Halog, Anthony

    2013-01-01

    This work reviews and performs a meta-analysis of the recent life cycle assessment and flow analyses studies palm oil biodiesel. The best available data and information are extracted, summarized, and discussed. Most studies found palm oil biodiesel would produce positive energy balance with an energy ratio between 2.27 and 4.81, and with a net energy production of 112 GJ ha(-1) y(-1). With the exception of a few studies, most conclude that palm oil biodiesel is a net emitter of greenhouse gases (GHG). The origin of oil palm plantation (planted area) is the foremost determinant of GHG emissions and C payback time (CPBT). Converting peatland forest results in GHG emissions up to 60 tons CO(2) equivalent (eq) ha(-1) y(-1) leading to 420 years of CPBT. In contrast, converting degraded land or grassland for plantation can positively offset the system to become a net sequester of 5 tons CO(2) eq ha(-1) y(-1). Few studies have discussed cradle-to-grave environmental impacts such as acidification, eutrophication, toxicity, and biodiversity, which open opportunity for further studies. Copyright © 2012 SETAC.

  1. Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, R.; Leach, M.; Bonnema, E.

    The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations aremore » applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.« less

  2. Energy performance of areas for urban development (Arkhangelsk is given as example)

    NASA Astrophysics Data System (ADS)

    Popova, Olga; Glebova, Yulia

    2017-01-01

    The present research provides an overview and analysis of the legal framework and the technology to increase energy save and energy efficiency. The challenges of the mentioned activities implementation in urban areas are revealed in the paper. A comparison was made of the principal methods of increasing energy efficiency that is based on payback period. The basic shortcomings of the methods used are found. The way of capital reproducing assets acquisition is proposed with consideration of the rate of wear and tear and upgrading of urban residential development. The present research aims at characterizing energy sustainability of urban areas for forming the information basis that identifies capital construction projects together within the urban area. A new concept - area energy sustainability is introduced in the study to use system-structural approach to energy saving and energy efficiency. Energy sustainability of the area as an integral indicator of the static characteristics of the territory is considered as a complex involving the following terms: energy security, energy intensity and energy efficiency dynamic indicators of all the components of the power system of the area. Dimensions and parameters of energy sustainability of the area are determined. Arkhangelsk is given as example.

  3. Placement and efficiency effects on radiative forcing of solar installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burg, Brian R.; Ruch, Patrick; Paredes, Stephan

    2015-09-28

    The promise for harnessing solar energy being hampered by cost, triggered efforts to reduce them. As a consequence low-efficiency, low-cost photovoltaics (PV) panels prevail. Conversely, in the traditional energy sector efficiency is extremely important due to the direct costs associated to fuels. This also affects solar energy due to the radiative forcing caused by the dark solar panels. In this paper we extend the concept of energy payback time by including the effect of albedo change, which gives a better assessment of the system sustainability. We present an analysis on the short and medium term climate forcing effects of differentmore » solar collectors in Riyadh, Saudi Arabia and demonstrate that efficiency is important to reduce the collector area and cost. This also influences the embodied energy and the global warming potential. We show that a placement of a high concentration photovoltaic thermal solar power station outside of the city using a district cooling system has a double beneficial effect since it improves the solar conversion efficiency and reduces the energy demand for cooling in the city. We also explain the mechanisms of the current economic development of solar technologies and anticipate changes.« less

  4. The effects of regeneration temperature of the desiccant wheel on the performance of desiccant cooling cycles for greenhouse thermally insulated

    NASA Astrophysics Data System (ADS)

    Rjibi, Amel; Kooli, Sami; Guizani, Amenaallah

    2018-05-01

    The use of solar energy for cooling greenhouses in the hot period in Mediterranean climate is an important issue. Desiccant evaporative cooling (DEC) system is advantageous because it uses a low grade thermal energy and preserves the merits to be friendly environmentally technology. In this paper, a numerical investigation was carried out on a desiccant cooling system powered by air solar collectors coupled to an insulated greenhouse. The influence of the regeneration temperature on the air stream properties at every system component state point was studied. The performance of the desiccant cooling system was evaluated in terms of thermal and electric coefficient of performance. Results show that the best performance of the system (COPel = 14 and COPth = 0.94) was obtained for a 60 °C regeneration temperature and a supply flow rate ratio of 0.2. An economic analysis shows that the use of the DEC system for greenhouse cooling is attractive and profitable since the payback period is 1 years. The use of the proposed system allows saving 9396 kWh/year of electric energy compared to conventional system.

  5. Energy sustainability of Microbial Fuel Cell (MFC): A case study

    NASA Astrophysics Data System (ADS)

    Tommasi, Tonia; Lombardelli, Giorgia

    2017-07-01

    Energy sustainability analysis and durability of Microbial Fuel Cells (MFCs) as energy source are necessary in order to move from the laboratory scale to full-scale application. This paper focus on these two aspects by considering the energy performances of an original experimental test with MFC conducted for six months under an external load of 1000 Ω. Energy sustainability is quantified using Energy Payback Time, the time necessary to produce the energy already spent to construct the MFC device. The results of experiment reveal that the energy sustainability of this specific MFC is never reached due to energy expenditure (i.e. for pumping) and to the low amount of energy produced. Hence, different MFC materials and architectures were analysed to find guidelines for future MFC development. Among these, only sedimentary fuel cells (Benthic MFCs) seem sustainable from an energetic point of view, with a minimum duration of 2.7 years. An energy balance approach highlights the importance of energy calculation. However, this is very often not taken into account in literature. This study outlines promising methodology for the design of an alternative layout of energy sustainable MFC and wastewater management systems.

  6. Technical and Socioeconomic Potential of Biogas from Cassava Waste in Ghana

    PubMed Central

    Kemausuor, Francis; Addo, Ahmad; Darkwah, Lawrence

    2015-01-01

    This study analyses technical potential and ex ante socioeconomic impacts of biogas production using cassava waste from agroprocessing plants. An analysis was performed for two biodigesters in two cassava processing communities in Ghana. The results showed that the two communities generate an excess of 4,500 tonnes of cassava peels per year. Using approximately 5% of the peels generated and livestock manure as inoculum can generate approximately 75,000 m3 of gas with an estimated 60% methane content from two separate plants of capacities 500 m3 and 300 m3 in the two communities. If used internally as process fuel, the potential gas available could replace over 300 tonnes of firewood per year for cassava processing. The displacement of firewood with gas could have environmental, economic, and social benefits in creating sustainable development. With a 10 percent discount rate, an assumed 20-year biodigester will have a Net Present Value of approximately US$ 148,000, 7-year Payback Period, and an Internal Rate of Return of 18.7%. The project will create 10 full-time unskilled labour positions during the investment year and 4 positions during operation years. PMID:26664752

  7. Wood-fired fuel cells in selected buildings

    NASA Astrophysics Data System (ADS)

    McIlveen-Wright, D. R.; McMullan, J. T.; Guiney, D. J.

    The positive attributes of fuel cells for high efficiency power generation at any scale and of biomass as a renewable energy source which is not intermittent, location-dependent or very difficult to store, suggest that a combined heat and power (CHP) system consisting of a fuel cell integrated with a wood gasifier (FCIWG) may offer a combination for delivering heat and electricity cleanly and efficiently. Phosphoric acid fuel cell (PAFC) systems, fuelled by natural gas, have already been used in a range of CHP applications in urban settings. Some of these applications are examined here using integrated biomass gasification/fuel cell systems in CHP configurations. Five building systems, which have different energy demand profiles, are assessed. These are a hospital, a hotel, a leisure centre, a multi-residential community and a university hall of residence. Heat and electricity use profiles for typical examples of these buildings were obtained and the FCIWG system was scaled to the power demand. The FCIWG system was modelled for two different types of fuel cell, the molten carbonate and the phosphoric acid. In each case an oxygen-fired gasification system is proposed, in order to eliminate the need for a methane reformer. Technical, environmental and economic analyses of each version were made, using the ECLIPSE process simulation package. Since fuel cell lifetimes are not yet precisely known, economics for a range of fuel cell lifetimes have been produced. The wood-fired PAFC system was found to have low electrical efficiency (13-16%), but much of the heat could be recovered, so that the overall efficiency was 64-67%, suitable where high heat/electricity values are required. The wood-fired molten carbonate fuel cell (MCFC) system was found to be quite efficient for electricity generation (24-27%), with an overall energy efficiency of 60-63%. The expected capital costs of both systems would currently make them uncompetitive for general use, but the specific features of selected buildings in rural areas, with regard to the high cost of importing other fuel, and/or lack of grid electricity, could still make these systems attractive options. Any economic analysis of these systems is beset with severe difficulties. Capital costs of the major system components are not known with any great precision. However, a guideline assessment of the payback period for such CHP systems was made. When the best available capital costs for system components were used, most of these systems were found to have unacceptably long payback periods, particularly where the fuel cell lifetimes are short, but the larger systems show the potential for a reasonable economic return.

  8. Capture of liquid hydrogen boiloff with metal hydride absorbers

    NASA Technical Reports Server (NTRS)

    Rosso, M. J.; Golben, P. M.

    1984-01-01

    A procedure which uses metal hydrides to capture some of this low pressure (,1 psig) hydrogen for subsequent reliquefaction is described. Of the five normally occurring sources of boil-off vapor the stream associated with the off-loading of liquid tankers during dewar refill was identified as the most cost effective and readily recoverable. The design, fabrication and testing of a proof-of-concept capture device, operating at a rate that is commensurate with the evolution of vapor by the target stream, is described. Liberation of the captured hydrogen gas at pressure .15 psig at normal temperatures (typical liquefier compressor suction pressure) are also demonstrated. A payback time of less than three years is projected.

  9. Improving Motor and Drive System Performance – A Sourcebook for Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This sourcebook outlines opportunities to improve motor and drive systems performance. The sourcebook is divided into four main sections: (1) Motor and Drive System Basics: Summarizes important terms, relationships, and system design considerations relating to motor and drive systems. (2) Performance Opportunity Road Map: Details the key components of well-functioning motor and drive systems and opportunities for energy performance opportunities. (3) Motor System Economics: Offers recommendations on how to propose improvement projects based on corporate priorities, efficiency gains, and financial payback periods. (4) Where to Find Help: Provides a directory of organizations associated with motors and drives, as well asmore » resources for additional information, tools, software, videos, and training opportunities.« less

  10. Study of the application of solar chemical dehumidification system to wind tunnel facilities of NASA Lewis Research Center at Cleveland, Ohio

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Energy utilization and cost payback analyses were prepared for proposed modifications. A 50,000 CFM standard compact packaged solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing solar energy and is stored in a storage tank. A steam boiler is provided as a back-up for the solar system. A 50,000 CFM standard compact package solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing a steam boiler and a heat exchanger and is stored in a storage tank.

  11. Defining quality health care with outcomes assessment while achieving economic value.

    PubMed

    Shaw, L J; Miller, D D

    2000-02-01

    The effectiveness of a procedure is increasingly guided by the evaluation of patient outcomes. Outcomes data is used to develop clinical pathways of care and to define appropriate resource-use levels without sacrificing quality of care. Integration of the economic implications of medical services into an outcome-based guideline allows for the development of disease-management strategies. In cardiovascular medicine, risk reduction is associated with high cost due to the "pay-back" of new technologies and therapies. A major challenge is to define a balance between "high tech" care and cost. This paper devises an outpatient evidence-based guideline using clinical and economic outcomes data for the diagnosis of coronary disease.

  12. Design of solar systems in high-rise buildings

    NASA Astrophysics Data System (ADS)

    Kolosov, Alexander; Chudinov, Dmitry; Yaremenko, Sergey

    2018-03-01

    Nowadays, the renovation program is being implemented in the megapolises of Russia. Innovative high-rise buildings are built instead of morally and physically obsolete houses, where non-traditional renewable energy sources are used to the fullest extent, under the effect of which they are located. The possibility to use solar systems with variation of their design parameters is considered. It is established that solar systems have high technical potential. The share of heat load, that is provided by using solar energy, varies from 4 to 84% depending on the time of the year. Economic indicators restrain the use of such panels. The payback period is about 8 years at the current cost for thermal energy.

  13. Energy savings potential in air conditioners and chiller systems

    DOE PAGES

    Kaya, Durmus; Alidrisi, Hisham

    2014-01-22

    In the current paper we quantified and evaluated the energy saving potential in air conditioners and chiller systems. Here, we also showed how to reduce the cost of air conditioners and chiller systems in existing facilities on the basis of payback periods. Among the measures investigated were: (1) installing higher efficiency air conditioners, (2) installing higher efficiency chillers, (3) duty cycling air conditioning units, and (4) utilizing existing economizers on air conditioning units. For each method, examples were provided from Arizona, USA. In these examples, the amount of saved energy, the financial evaluation of this energy, and the investment costmore » and pay back periods were calculated.« less

  14. Integrated alternative energy systems for use in small communities

    NASA Astrophysics Data System (ADS)

    Thornton, J.

    1982-01-01

    This paper summarizes the principles and conceptual design of an integrated alternative energy system for use in typical farming communities in developing countries. A system is described that, utilizing the Sun and methane produced from crop waste, would supply sufficient electric and thermal energy to meet the basic needs of villagers for water pumping, lighting, and cooking. The system is sized to supply enough pumping capacity to irrigate 101 ha (249 acres) sufficiently to optimize annual crop yields for the community. Three economic scenarios were developed, showing net benefits to the community of $3,578 to $15,547 anually, payback periods of 9.5 to 20 years, and benefit-to-cost ratios of 1.1 to 1.9.

  15. Simple yet Hidden Counterexamples in Undergraduate Real Analysis

    ERIC Educational Resources Information Center

    Shipman, Barbara A.; Shipman, Patrick D.

    2013-01-01

    We study situations in introductory analysis in which students affirmed false statements as true, despite simple counterexamples that they easily recognized afterwards. The study draws attention to how simple counterexamples can become hidden in plain sight, even in an active learning atmosphere where students proposed simple (as well as more…

  16. Simple Numerical Analysis of Longboard Speedometer Data

    ERIC Educational Resources Information Center

    Hare, Jonathan

    2013-01-01

    Simple numerical data analysis is described, using a standard spreadsheet program, to determine distance, velocity (speed) and acceleration from voltage data generated by a skateboard/longboard speedometer (Hare 2012 "Phys. Educ." 47 409-17). This simple analysis is an introduction to data processing including scaling data as well as…

  17. Waste heat recovery options in a large gas-turbine combined power plant

    NASA Astrophysics Data System (ADS)

    Upathumchard, Ularee

    This study focuses on power plant heat loss and how to utilize the waste heat in energy recovery systems in order to increase the overall power plant efficiency. The case study of this research is a 700-MW natural gas combined cycle power plant, located in a suburban area of Thailand. An analysis of the heat loss of the combustion process, power generation process, lubrication system, and cooling system has been conducted to evaluate waste heat recovery options. The design of the waste heat recovery options depends to the amount of heat loss from each system and its temperature. Feasible waste heat sources are combustion turbine (CT) room ventilation air and lubrication oil return from the power plant. The following options are being considered in this research: absorption chillers for cooling with working fluids Ammonia-Water and Water-Lithium Bromide (in comparison) and Organic Rankine Cycle (ORC) with working fluids R134a and R245fa. The absorption cycles are modeled in three different stages; single-effect, double-effect and half-effect. ORC models used are simple ORC as a baseline, ORC with internal regenerator, ORC two-phase flash expansion ORC and ORC with multiple heat sources. Thermodynamic models are generated and each system is simulated using Engineering Equation Solver (EES) to define the most suitable waste heat recovery options for the power plant. The result will be synthesized and evaluated with respect to exergy utilization efficiency referred as the Second Law effectiveness and net output capacity. Results of the models give recommendation to install a baseline ORC of R134a and a double-effect water-lithium bromide absorption chiller, driven by ventilation air from combustion turbine compartment. The two technologies yield reasonable economic payback periods of 4.6 years and 0.7 years, respectively. The fact that this selected power plant is in its early stage of operation allows both models to economically and effectively perform waste heat recovery during the power plant's life span. Furthermore, the recommendation from this research will be submitted to the Electricity Generating Authority of Thailand (EGAT) for implementation. This study will also be used as an example for other power plants in Thailand to consider waste energy utilization to improve plant efficiency and sustain fuel resources in the future.

  18. Cost-benefit analysis of electronic medical record system at a tertiary care hospital.

    PubMed

    Choi, Jong Soo; Lee, Woo Baik; Rhee, Poong-Lyul

    2013-09-01

    Although Electronic Medical Record (EMR) systems provide various benefits, there are both advantages and disadvantages regarding its cost-effectiveness. This study analyzed the economic effects of EMR systems using a cost-benefit analysis based on the differential costs of managerial accounting. Samsung Medical Center (SMC) is a general hospital in Korea that developed an EMR system for outpatients from 2006 to 2008. This study measured the total costs and benefits during an 8-year period after EMR adoption. The costs include the system costs of building the EMR and the costs incurred in smoothing its adoption. The benefits included cost reductions after its adoption and additional revenues from both remodeling of paper-chart storage areas and medical transcriptionists' contribution. The measured amounts were discounted by SMC's expected interest rate to calculate the net present value (NPV), benefit-cost ratio (BCR), and discounted payback period (DPP). During the analysis period, the cumulative NPV and the BCR were US$3,617 thousand and 1.23, respectively. The DPP was about 6.18 years. Although the adoption of an EMR resulted in overall growth in administrative costs, it is cost-effective since the cumulative NPV was positive. The positive NPV was attributed to both cost reductions and additional revenues. EMR adoption is not so attractive to management in that the DPP is longer than 5 years at 6.18 and the BCR is near 1 at 1.23. However, an EMR is a worthwhile investment, seeing that this study did not include any qualitative benefits and that the paper-chart system was cost-centric.

  19. Estimating energy intensity and CO{sub 2} emission reduction potentials in the manufacturing sectors in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wangskarn, P.; Khummongkol, P.; Schrattenholzer, L.

    The final energy consumption in Thailand increased at about ten percent annually within the last 10 years. To slow the energy demand growth rate while maintaining the country`s economic advance and environmental sustainability, the Energy Conservation Promotion Act (ECPA) was adopted in 1992. With this Act, a comprehensive Energy Conservation Program (ENCON) was initiated. ENCON commits the government to promoting energy conservation, to developing appropriate regulations, and to providing financial and organizational resources for program implementation. Due to this existing ENCON program a great benefit is expected not only to reducing energy consumption, but also to decreasing GHGs emissions substantially.more » This study is a part of the ENCON research program which was supported by the German Federal Government under the program called Prompt-Start Measures to Implement the U.N. Framework Convention on Climate Change (FCCC). The basic activities carried out during the project included (1) An assessment of Thailand`s total and specific energy consumption in the industrial sectors and commercial buildings; (2) Identification of existing and candidate technologies for GHG emission reduction and energy efficiency improvements in specific factories and commercial buildings; and (3) Identification of individual factories and commercial buildings as candidates for detailed further study. Although the energy assessment had been carried out for the commercial buildings also, this paper will cover only the work on the manufacturing sector. On the basis of these steps, 14 factories were visited by the project team and preliminary energy audits were performed. As a result, concrete measures and investments were proposed and classified into two groups according to their economic characteristics. Those investments with a payback time of less than four years were considered together in a Moderate scenario, and those with longer payback times in an Intensive scenario.« less

  20. An assessment of health research impact in Iran.

    PubMed

    Yazdizadeh, Bahareh; Majdzadeh, Reza; Janani, Leila; Mohtasham, Farideh; Nikooee, Sima; Mousavi, Abdmohammad; Najafi, Farid; Atabakzadeh, Maryam; Bazrafshan, Azam; Zare, Morteza; Karami, Manoochehr

    2016-07-26

    In recent years, Iran has made significant developments in the field of health sciences. However, the question is whether this considerable increase has affected public health. The research budget has always been negligible and unsustainable in developing countries. Hence, using the Payback Framework, we conducted this study to evaluate the impact of health research in Iran. By using a cross-sectional method and two-stage stratified cluster sampling, the projects were randomly selected from six medical universities. A questionnaire was designed according to the Payback Framework and completed by the principle investigators of the randomly selected projects. The response rate was 70.4%. Ten point twenty-four percent (10.24%) of the studies had been ordered by a knowledge user organization. The average number of articles published in journals per project was 0.96, and half of the studies had no articles published in Scopus. The results of 12% of the studies had been used in systematic review articles and the same proportion had been utilized in clinical or public health guidelines. The results of 5.3% of the studies had been implemented in the Health Ministry's policymaking. 62% of the studies were expected to affect health directly, 38% of them had been implemented, and among the latter 60% had achieved the expected results. Concerning the economic impacts, the most common expected impact was the reduction of 'days of work missed because of illness or disability' and impact on personal and health system costs. About 36% of these studies had been implemented, and 61% had achieved the expected impact. In most aspects, the status of research impact needs improvement. A comparison of Iran's ranking of knowledge creation and knowledge impact in the Global Innovation Index confirms these findings. The most important problems identified were, not conducting research based on national needs, and the lack of implementation of research results.

  1. Electricity as Transportation ``Fuel''

    NASA Astrophysics Data System (ADS)

    Tamor, Michael

    2013-04-01

    The personal automobile is a surprisingly efficient device, but its place in a sustainable transportation future hinges on its ability use a sustainable fuel. While electricity is widely expected to be such a ``fuel,'' the viability of electric vehicles rests on the validity of three assumptions. First, that the emissions from generation will be significantly lower than those from competing chemical fuels whether `renewable' or fossil. Second, that advances in battery technology will deliver adequate range and durability at an affordable cost. Third, that most customers will accept any functional limitations intrinsic to electrochemical energy storage. While the first two are subjects of active research and vigorous policy debate, the third is treated virtually as a given. Popular statements to the effect that ``because 70% of all daily travel is accomplished in less than 100 miles, mass deployment of 100 mile EVs will electrify 70% of all travel'' are based on collections of one-day travel reports such as the National Household Travel Survey, and so effectively ignore the complexities of individual needs. We have analyzed the day-to-day variations of individual vehicle usage in multiple regions and draw very different conclusions. Most significant is that limited EV range results in a level of inconvenience that is likely to be unacceptable to the vast majority of vehicle owners, and for those who would accept that inconvenience, battery costs must be absurdly low to achieve any economic payback. In contrast, the plug-in hybrid (PHEV) does not suffer range limitations and delivers economic payback for most users at realistic battery costs. More importantly, these findings appear to be universal in developed nations, with labor market population density being a powerful predictor of personal vehicle usage. This ``scalable city'' hypothesis may prove to a powerful predictor of the evolution of transportation in the large cities of the developing world.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubin, F S; Halfon, A; Herzog, P

    The ice-generating HP-ICES uses the heat of fusion of water as a heat source for the heat pump, thus converting the water into ice. The ice will be stored in a bin and used the following summer for cooling which, therefore, could be considered a by-product of heating. The annual overall Coefficient of Performance is expected to reach a value of 4.85 and related to source energy a value of 4.85 x 0.31 = 1.5. In a detailed case study on the Market Square project in Washington, D.C., it was found that for the HP-ICES the annual source energy inputmore » is about 60% and the life cycle annual average cost is 40% of the corresponding quantities for a conventional central system with equal heating and cooling capacity. The annual average operating and administration cost for the HP-ICES is less than 70% of the corresponding costs for the conventional system, while the first cost of the HP-ICES is about 70% larger than the first cost of the conventional system. With the values assumed for the discount rate, interest rate, etc., the return on investment was found to be about 15%, which gives a discounted payback period of about 6.7 years. For the Park Plaza in Boston, the annual source energy input for the HP-ICES is 35% and the energy cost is about 30% of the corresponding quantities for the conventional system. The annual average operating and administration cost for the HP-ICES is 4.5 times as great as the first cost for the conventional system. The return on investment is 13% and the payback is 8 years. These results show that the HP-ICES can be better both in energy usage and in life cycle cost than a conventional system of the same heating and cooling capacity, and holds great promise as an energy saving system.« less

  3. A project of reuse of reclaimed wastewater in the Po Valley, Italy: Polishing sequence and cost benefit analysis

    NASA Astrophysics Data System (ADS)

    Verlicchi, P.; Al Aukidy, M.; Galletti, A.; Zambello, E.; Zanni, G.; Masotti, L.

    2012-04-01

    SummaryThe paper presents a study carried out in the environmentally sensitive area of the Po Valley in northern Italy, with the aim of evaluating, from technical and economic perspectives, a project to reuse part of the final effluent from the Ferrara wastewater treatment plant for irrigation and to develop the site for recreational purposes. Although this area features plentiful supplies of surface water, the Ministry of the Environment has declared it to be at risk of environmental crises due to eutrophication and the drought recurring over the last decade. Thus the availability of fresh water, particularly for agricultural purposes, is threatened, and prompt water saving and protection measures are required. Hence, the possibility of reusing reclaimed wastewater from this plant was investigated, with the aim of exploiting the space around the WWTP, situated within a large urban park, to install natural polishing treatment systems and create green spaces for recreational use. Based on experimental investigation on a pilot plant (featuring both natural and conventional treatments), the study outlines the rationale behind the treatment train selected for the project, details the initial and ongoing costs involved, evaluates the benefits deriving from the project, and assesses public acceptance of the project by the contingent valuation method. A cost-benefit analysis completes the study, and various economic indicators (net present value, benefit-cost ratio, pay-back period, and internal rate of return) revealed that the proposed project was financially feasible.

  4. Incorporating Non-energy Benefits into Energy Savings Performance Contracts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Peter; Goldman, Charles; Gilligan, Donald

    2012-06-01

    This paper evaluates the issue of non-energy benefits within the context of the U.S. energy services company (ESCO) industry?a growing industry comprised of companies that provide energy savings and other benefits to customers through the use of performance-based contracting. Recent analysis has found that ESCO projects in the public/institutional sector, especially at K-12 schools, are using performance-based contracting, at the behest of the customers, to partially -- but not fully -- offset substantial accumulated deferred maintenance needs (e.g., asbestos removal, wiring) and measures that have very long paybacks (roof replacement). This trend is affecting the traditional economic measures policymakers usemore » to evaluate success on a benefit to cost basis. Moreover, the value of non-energy benefits which can offset some or all of the cost of the non-energy measures -- including operations and maintenance (O&M) savings, avoided capital costs, and tradable pollution emissions allowances-- are not always incorporated into a formal cost-effectiveness analysis of ESCO projects. Nonenergy benefits are clearly important to customers, but state and federal laws that govern the acceptance of these types of benefits for ESCO projects vary widely (i.e., 0-100percent of allowable savings can come from one or more non-energy categories). Clear and consistent guidance on what types of savings are recognized in Energy Savings agreements under performance contracts is necessary, particularly where customers are searching for deep energy efficiency gains in the building sector.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tracy, Jennifer; Mills, Evan

    The Lumina Project and Lighting Africa conducted a full-scale field test involving a switch from kerosene to solar-LED lighting for commercial broiler chicken production at an off-grid farm in Kenya. The test achieved lower operating costs, produced substantially more light, improved the working environment, and had no adverse effect on yields. A strategy using conventional solar-fluorescent lighting also achieved comparable yields, but entailed a six-fold higher capital cost and significantly higher recurring battery replacement costs. Thanks to higher energy and optical efficiencies, the LED system provided approximately twice the illumination to the chicken-production area and yet drew less than halfmore » the power.At the study farm, 3000 chickens were grown in each of three identical houses under kerosene, fluorescent, and LED lighting configurations. Under baseline conditions, a yearly expenditure of 1,200 USD is required to illuminate the three houses with kerosene. The LED system eliminates this fuel use and expense with a corresponding simple payback time of 1.5 years, while the solar-fluorescent system has a payback time of 9.3 years. The corresponding reduction in fuel expenditure in both cases represents a 15percent increase in after-tax net income (revenues minus expenses) across the entire business operation. The differential cost-effectiveness between the LED and fluorescent systems would be substantially greater if the fluorescent system were upsized to provide the same light as the LED system. Providing light with the fluorescent or LED systems is also far more economical than connecting to the grid in this case. The estimated grid-connection cost at this facility is 1.7 million Kenya Schillings (approximately 21,250 USD), which is nearly six-times the cost of the fluorescent system and 35-times the cost of the LED system.The LED system also confers various non-energy benefits. The relative uniformity of LED lighting, compared to the fluorescent or kerosene lighting, reduced crowding which in turn created a less stressful environment for the chickens. The far higher levels of illumination also created a better environment for the workers, while eliminating the time required for obtaining fuel and maintaining kerosene lanterns. An additional advantage of the LED system relative to the solar fluorescent system was that the former does not require a skilled technician to carry out the installation. The portable LED system lighting layout is also more easily adjusted than that of the hardwired fluorescent systems. Furthermore, switching to the LED system avoids over one metric ton of carbon dioxide emissions per house on an annual basis compared to kerosene. There is high potential for replication of this particular LED lighting strategy in the developing world. In order to estimate the scale of kerosene use and the potential for savings, more information is needed on the numbers of chickens produced off-grid, as well as lighting uses for other categories of poultry production (egg layers, indigenous broilers ). Our discovery that weight gain did not slow in the solar-fluorescent house after it experienced extended lighting outages beginning on day 14 of the 35-day study suggests that conventional farming practices in Kenyan broiler operations may call for more hours of lighting than is needed to achieve least-cost production.« less

  6. Walking beam furnace well-way slot covers at Rouge Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, F. Jr.; Meinzinger, A.D.; Faust, C.H.

    1993-07-01

    Rouge Steel's 68-in. hot strip mill is served by three walking beam slab reheat furnaces. The first two were commissioned in 1974 and the third was installed in 1980. During the period 1979 to 1981, an intensive plant-wide energy management program to reduce energy consumption was undertaken. A major part of that program involved a comprehensive upgrading of refractory and insulation systems utilized in the walking beam reheat furnaces. A durable system for reducing heat losses through the well-way floor openings associated with walking beam slab reheat furnaces has, in addition to 4 to 5% savings in fuel consumption, reducedmore » maintenance costs. Payback is achieved in four to five months.« less

  7. The Economics of Private Sector R and D Decisionmaking in Aeronautics

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Information which can be used in planning to insure commercial research and technology programs which are complementary to internally financed private sector activities are presented. The main concern is to identify the characteristics of productive projects in which firms are unlikely to invest. It is shown that: (1) if it is difficult to assess the commercial relevance of an R&D project or it it is characterized by high technical risk, or a relatively long payback period, private funding will be unlikely; and (2) if a project is large relative to the size of the firm, it is unlikely to be funded in the early stages of the R&D process. Firms tend to underinvest in projects with these characteristics.

  8. Data on electrical energy conservation using high efficiency motors for the confidence bounds using statistical techniques.

    PubMed

    Shaikh, Muhammad Mujtaba; Memon, Abdul Jabbar; Hussain, Manzoor

    2016-09-01

    In this article, we describe details of the data used in the research paper "Confidence bounds for energy conservation in electric motors: An economical solution using statistical techniques" [1]. The data presented in this paper is intended to show benefits of high efficiency electric motors over the standard efficiency motors of similar rating in the industrial sector of Pakistan. We explain how the data was collected and then processed by means of formulas to show cost effectiveness of energy efficient motors in terms of three important parameters: annual energy saving, cost saving and payback periods. This data can be further used to construct confidence bounds for the parameters using statistical techniques as described in [1].

  9. An Economic Analysis of a Safe Resident Handling Program in Nursing Homes

    PubMed Central

    Lahiri, Supriya; Latif, Saira; Punnett, Laura

    2018-01-01

    Background Occupational injuries, especially back problems related to resident handling, are common in nursing home employees and their prevention may require substantial up-front investment. This study evaluated the economics of a safe resident handling program (SRHP), in a large chain of skilled nursing facilities, from the corporation's perspective. Methods The company provided data on program costs, compensation claims, and turnover rates (2003-2009). Workers' compensation and turnover costs before and after the intervention were compared against investment costs using the “net-cost model”. Results Among 110 centers, the overall benefit-to-cost ratio was 1.7–3.09 and the payback period was 1.98–1.06 year (using alternative turnover cost estimates). The average annualized net savings per bed for the 110 centers (using company based turnover cost estimates) was $143, with a 95% confidence interval of $22–$264. This was very similar to the average annualized net savings per full time equivalent (FTE) staff member, which was $165 (95% confidence interval $22–$308). However, at 49 centers costs exceeded benefits. Conclusions Decreased costs of worker injury compensation claims and turnover appear at least partially attributable to the SRHP. Future research should examine center-specific factors that enhance program success, and improve measures of turnover costs and healthcare productivity. PMID:23203729

  10. An economic analysis of a safe resident handling program in nursing homes.

    PubMed

    Lahiri, Supriya; Latif, Saira; Punnett, Laura

    2013-04-01

    Occupational injuries, especially back problems related to resident handling, are common in nursing home employees and their prevention may require substantial up-front investment. This study evaluated the economics of a safe resident handling program (SRHP), in a large chain of skilled nursing facilities, from the corporation's perspective. The company provided data on program costs, compensation claims, and turnover rates (2003-2009). Workers' compensation and turnover costs before and after the intervention were compared against investment costs using the "net-cost model." Among 110 centers, the overall benefit-to-cost ratio was 1.7-3.09 and the payback period was 1.98-1.06 year (using alternative turnover cost estimates). The average annualized net savings per bed for the 110 centers (using company based turnover cost estimates) was $143, with a 95% confidence interval of $22-$264. This was very similar to the average annualized net savings per full time equivalent (FTE) staff member, which was $165 (95% confidence interval $22-$308). However, at 49 centers costs exceeded benefits. Decreased costs of worker injury compensation claims and turnover appear at least partially attributable to the SRHP. Future research should examine center-specific factors that enhance program success, and improve measures of turnover costs and healthcare productivity. Copyright © 2012 Wiley Periodicals, Inc.

  11. Tracking blood products in blood centres using radio frequency identification: a comprehensive assessment.

    PubMed

    Davis, Rodeina; Geiger, Bradley; Gutierrez, Alfonso; Heaser, Julie; Veeramani, Dharmaraj

    2009-07-01

    Radio frequency identification (RFID) can be a key enabler for enhancing productivity and safety of the blood product supply chain. This article describes a systematic approach developed by the RFID Blood Consortium for a comprehensive feasibility and impact assessment of RFID application in blood centre operations. Our comprehensive assessment approach incorporates process-orientated and technological perspectives as well as impact analysis. Assessment of RFID-enabled process redesign is based on generic core processes derived from the three participating blood centres. The technological assessment includes RFID tag readability and performance evaluation, testing of temperature and biological effects of RF energy on blood products, and RFID system architecture design and standards. The scope of this article is limited to blood centre processes (from donation to manufacturing/distribution) for selected mainstream blood products (red blood cells and platelets). Radio frequency identification can help overcome a number of common challenges and process inefficiencies associated with identification and tracking of blood products. High frequency-based RFID technology performs adequately and safely for red blood cell and platelet products. Productivity and quality improvements in RFID-enabled blood centre processes can recoup investment cost in a 4-year payback period. Radio frequency identification application has significant process-orientated and technological implications. It is feasible and economically justifiable to incorporate RFID into blood centre processes.

  12. Technical and economic analysis use of flare gas into alternative energy as a breakthrough in achieving zero routine flaring

    NASA Astrophysics Data System (ADS)

    Petri, Y.; Juliza, H.; Humala, N.

    2018-03-01

    The activity of exploring natural oil and gas will produce gas flare 0.584 MMSCFD. A gas flare is the combustion of gas remaining to avoid poisonous gas like H2S and CO which is very dangerous for human and environmental health. The combustion can bring about environmental pollution and losses because it still contains valuable energy. It needs the policy to encourage the use of flare gas with Zero Routine Flaring and green productivity to reduce waste and pollution. The objective of the research was to determine the use of gas flare so that it will have economic value and can achieve Zero Routine Flaring. It was started by analysing based on volume or rate and composition gas flare was used to determine technical feasibility, and the estimation of the gas reserves as the determination of the economy of a gas well. The results showed that the use of flare gas as fuel for power generation feasible to be implemented technically and economically with Internal Rate of Return (IRR) 19.32% and the Payback Period (PP) 5 year. Thus, it can increase gas flare value economically and can achieve a breakthrough in Zero Routine Flaring.

  13. Thermo Dynamics and Economics Evaluations: Substitution of the Extraction Steam with the Wasted Heat of Flue Gas

    NASA Astrophysics Data System (ADS)

    Hao, Lifen; Qiu, Lixia; Li, Jinping; Li, Dongxiong

    2018-01-01

    A new heat supplying system is proposed that utilizes the exhausted gas of the boiler to substitute the extraction steam from the turbine as the driving force for the adsorption heat pump regarding the recovery of the condensation heat of power plant. However, our system is not subject to the low efficiency of wasted heat utilization due to the low temperature of flue gas, which hence possesses higher performance in COP factors in the utilization of heat than that of the conventional techniques of using flues gas, so the amount of extracted gas from turbine can be reduced and the power generate rate be enhanced. Subsequently, detailed evaluation of the performance of this system in the point of views of thermodynamics and economics are presented in this work. For the instance of a 330 MW heat supply unit, 5 sample cities are chosen to demonstrate and confirm our economic analysis. It is revealed that when the heating coefficient of the heat pump is 1.8, the investment payback periods for these 5 cities are within the range of 2.4 to 4.8 years, which are far below the service year of the heat pump, demonstrating remarkable economic benefits for our system.

  14. An Experimental Study of Briquetting Process of Torrefied Rubber Seed Kernel and Palm Oil Shell.

    PubMed

    Hamid, M Fadzli; Idroas, M Yusof; Ishak, M Zulfikar; Zainal Alauddin, Z Alimuddin; Miskam, M Azman; Abdullah, M Khalil

    2016-01-01

    Torrefaction process of biomass material is essential in converting them into biofuel with improved calorific value and physical strength. However, the production of torrefied biomass is loose, powdery, and nonuniform. One method of upgrading this material to improve their handling and combustion properties is by densification into briquettes of higher density than the original bulk density of the material. The effects of critical parameters of briquetting process that includes the type of biomass material used for torrefaction and briquetting, densification temperature, and composition of binder for torrefied biomass are studied and characterized. Starch is used as a binder in the study. The results showed that the briquette of torrefied rubber seed kernel (RSK) is better than torrefied palm oil shell (POS) in both calorific value and compressive strength. The best quality of briquettes is yielded from torrefied RSK at the ambient temperature of briquetting process with the composition of 60% water and 5% binder. The maximum compressive load for the briquettes of torrefied RSK is 141 N and the calorific value is 16 MJ/kg. Based on the economic evaluation analysis, the return of investment (ROI) for the mass production of both RSK and POS briquettes is estimated in 2-year period and the annual profit after payback was approximately 107,428.6 USD.

  15. Waste management in the meat processing industry: Conversion of paunch and DAF sludge into solid fuel.

    PubMed

    Hamawand, Ihsan; Pittaway, Pam; Lewis, Larry; Chakrabarty, Sayan; Caldwell, Justin; Eberhard, Jochen; Chakraborty, Arpita

    2017-02-01

    This article addresses the novel dewatering process of immersion-frying of paunch and dissolved air flotation (DAF) sludge to produce high energy pellets. Literature have been analysed to address the feasibility of replacing conventional boiler fuel at meat processing facilities with high energy paunch-DAF sludge pellets (capsules). The value proposition of pelleting and frying this mixture into energy pellets is based on a Cost-Benefit Analysis (CBA). The CBA is based on information derived from the literature and consultation with the Australian Meat Processing Industry. The calorific properties of a mixture of paunch cake solids and DAF sludge were predicted from literature and industry consultation to validate the product. This study shows that the concept of pelletizing and frying paunch is economically feasible. The complete frying and dewatering of the paunch and DAF sludge mixture produces pellets with energy content per kilogram equivalent to coal. The estimated cost of this new product is half the price of coal and the payback period is estimated to be between 1.8 and 3.2years. Further research is required for proof of concept, and to identify the technical challenges associated with integrating this technology into existing meat processing plants. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  16. The US Orphan Drug Act: rare disease research stimulator or commercial opportunity?

    PubMed

    Wellman-Labadie, Olivier; Zhou, Youwen

    2010-05-01

    This study investigates issues associated with the United States Orphan Drug Act. A comprehensive orphan drug database was compiled from FDA data and corporate annual reports of major pharmaceutical companies. Analysis allowed the generation of a descriptive orphan drug portrait as well as documentation of orphan drugs along their lifecycle. Currently, 2002 products have obtained orphan drug designation with 352 drugs obtaining FDA approval. Approximately 33% of orphan drugs are oncology products. On average, products obtain 1.7 orphan designations with approximately 70% obtaining a single designation. At least 9% of orphan drugs have reached blockbuster status with two-thirds having two or more designations. An additional 25 orphan drugs had sales exceeding US$ 100 million in 2008 alone. Since 1983, at least 14 previously discontinued products have been recycled as orphan drugs. The United States Orphan Drug Act has created issues which, in some cases, have led to commercial and ethical abuses. Orphan Drug Act reform is necessary but current incentives, including 7 year market exclusivity, should be maintained in order to favour patients as well as economic prosperity. Suggested reforms include price regulation, subsidy paybacks for profitable drugs and the establishment of an International Orphan Drug Office. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Environmental Impacts from Photovoltaic Solar Cells Made with Single Walled Carbon Nanotubes.

    PubMed

    Celik, Ilke; Mason, Brooke E; Phillips, Adam B; Heben, Michael J; Apul, Defne

    2017-04-18

    An ex-ante life cycle inventory was developed for single walled carbon nanotube (SWCNT) PV cells, including a laboratory-made 1% efficient device and an aspirational 28% efficient four-cell tandem device. The environmental impact of unit energy generation from the mono-Si PV technology was used as a reference point. Compared to monocrystalline Si (mono-Si), the environmental impacts from 1% SWCNT was ∼18 times higher due mainly to the short lifetime of three years. However, even with the same short lifetime, the 28% cell had lower environmental impacts than mono-Si. The effects of lifetime and efficiency on the environmental impacts were further examined. This analysis showed that if the SWCNT device efficiency had the same value as the best efficiency of the material under comparison, to match the total normalized impacts of the mono- and poly-Si, CIGS, CdTe, and a-Si devices, the SWCNT devices would need a lifetime of 2.8, 3.5, 5.3, 5.1, and 10.8 years, respectively. It was also found that if the SWCNT PV has an efficiency of 4.5% or higher, its energy payback time would be lower than other existing and emerging PV technologies. The major impacts of SWCNT PV came from the cell's materials synthesis.

  18. On the (In)Validity of Tests of Simple Mediation: Threats and Solutions

    PubMed Central

    Pek, Jolynn; Hoyle, Rick H.

    2015-01-01

    Mediation analysis is a popular framework for identifying underlying mechanisms in social psychology. In the context of simple mediation, we review and discuss the implications of three facets of mediation analysis: (a) conceptualization of the relations between the variables, (b) statistical approaches, and (c) relevant elements of design. We also highlight the issue of equivalent models that are inherent in simple mediation. The extent to which results are meaningful stem directly from choices regarding these three facets of mediation analysis. We conclude by discussing how mediation analysis can be better applied to examine causal processes, highlight the limits of simple mediation, and make recommendations for better practice. PMID:26985234

  19. Bedside ROP screening and telemedicine interpretation integrated to a neonatal transport system: Economic aspects and return on investment analysis.

    PubMed

    Kovács, Gábor; Somogyvári, Zsolt; Maka, Erika; Nagyjánosi, László

    Peter Cerny Ambulance Service - Premature Eye Rescue Program (PCA-PERP) uses digital retinal imaging (DRI) with remote interpretation in bedside ROP screening, which has advantages over binocular indirect ophthalmoscopy (BIO) in screening of premature newborns. We aimed to demonstrate that PCA-PERP provides good value for the money and to model the cost ramifications of a similar newly launched system. As DRI was demonstrated to have high diagnostic performance, only the costs of bedside DRI-based screening were compared to those of traditional transport and BIO-based screening (cost-minimization analysis). The total costs of investment and maintenance were analyzed with micro-costing method. A ten-year analysis time-horizon and service provider's perspective were applied. From the launch of PCA-PERP up to the end of 2014, 3722 bedside examinations were performed in the PCA covered central region of Hungary. From 2009 to 2014, PCA-PERP saved 92,248km and 3633 staff working hours, with an annual nominal cost-savings ranging from 17,435 to 35,140 Euro. The net present value was 127,847 Euro at the end of 2014, with a payback period of 4.1years and an internal rate of return of 20.8%. Our model presented the NPVs of different scenarios with different initial investments, annual number of transports and average transport distances. PCA-PERP as bedside screening with remote interpretation, when compared to a transport-based screening with BIO, produced better cost-savings from the perspective of the service provider and provided a return on initial investment within five years after the project initiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Comprehensive assessment of the L-lysine production process from fermentation of sugarcane molasses.

    PubMed

    Anaya-Reza, Omar; Lopez-Arenas, Teresa

    2017-07-01

    L-Lysine is an essential amino acid that can be produced by chemical processes from fossil raw materials, as well as by microbial fermentation, the latter being a more efficient and environmentally friendly procedure. In this work, the production process of L-lysine-HCl is studied using a systematic approach based on modeling and simulation, which supports decision making in the early stage of process design. The study considers two analysis stages: first, the dynamic analysis of the fermentation reactor, where the conversion of sugars from sugarcane molasses to L-lysine with a strain of Corynebacterium glutamicum is carried out. In this stage, the operation mode (either batch or fed batch) and operating conditions of the fermentation reactor are defined to reach the maximum technical criteria. Afterwards, the second analysis stage relates to the industrial production process of L-lysine-HCl, where the fermentation reactor, upstream processing, and downstream processing are included. In this stage, the influence of key parameters on the overall process performance is scrutinized through the evaluation of several technical, economic, and environmental criteria, to determine a profitable and sustainable design of the L-lysine production process. The main results show how the operating conditions, process design, and selection of evaluation criteria can influence in the conceptual design. The best plant design shows maximum product yield (0.31 g L-lysine/g glucose) and productivity (1.99 g/L/h), achieving 26.5% return on investment (ROI) with a payback period (PBP) of 3.8 years, decreasing water and energy consumption, and with a low potential environmental impact (PEI) index.

  1. Development of an innovative solar absorber

    NASA Astrophysics Data System (ADS)

    Goodchild, Gavin

    Solar thermal systems have great potential to replace or reduce the dependence of conventional fossil fuel based heating technologies required for space and water heating. Specifically solar domestic hot water systems can contribute 50-75% of the annual thermal load. To date residential users have been slow to purchase and install systems, primarily due to the large monetary investment required to purchase and install a system. Recent innovations in materials design and manufacturing techniques, offer opportunities for the development of absorber plate designs that have the potential to reduce cost, increase efficiency and reduce payback periods. Consequently, this design study was conducted in conjunction with industrial partners to develop an improved absorber based on roll bond manufacturing that can be produced at reduced cost with comparable or greater thermal efficiency.

  2. Industrial Assessment Centers - Small Manufacturers Reduce Energy & Increase Productivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Since 1976, the Industrial Assessment Centers (IACs), administered by the US Department of Energy, have supported small and medium-sized American manufacturers to reduce energy use and increase their productivity and competitiveness. The 24 IACs, located at premier engineering universities around the country (see below), send faculty and engineering students to local small and medium-sized manufacturers to provide no-cost assessments of energy use, process performance and waste and water flows. Under the direction of experienced professors, IAC engineering students analyze the manufacturer’s facilities, energy bills and energy, waste and water systems, including compressed air, motors/pumps, lighting, process heat and steam. Themore » IACs then follow up with written energy-saving and productivity improvement recommendations, with estimates of related costs and payback periods.« less

  3. The solar power satellite concepts: The past decade and the next decade

    NASA Technical Reports Server (NTRS)

    Kraft, C. C., Jr.

    1979-01-01

    Results of studies on the solar power satellite concept are summarized. The basic advantages are near continuous access to sunlight and freedom from atmospheric effects and cloud cover. The systems definition studies consider photovoltaic and thermal energy conversion systems and find both to be technically feasible, with the photovoltaic approach preferred. A microwave test program is under way which will provide quantitative data on critical parameters, including beam forming and steering accuracy. Ballistic and winged launch vehicles are defined for the transportation of construction materials, with the shuttle expected to provide low cost transportation to and from space. A reference system is outlined for evaluating the concept in terms of environmental and other considerations. Preliminary estimates of natural resource requirements and energy payback intervals are encouraging.

  4. On Adaptive Extended Different Life Cycle of Product Design Strategy

    NASA Astrophysics Data System (ADS)

    Wenwen, Jiang; Zhibin, Xie

    The article uses research ways of following the whole lifespan of product and enterprise's development course to research strategy of company's product design and development. It announces enterprises of different nature, enterprises at different developing stage will adopt different mode strategy. It also announces close causality between development course of company and central technology and product. The result indicated in different developing stages such as company development period, crisis predicament period, lasting steadies period, improving by payback period, issues steadies secondary period, declining go and live period, enterprise should pursue different mode product tactics of research and development such as shrinking strategy, consolidating strategy, innovation keeping forging ahead strategy. Enterprise should break regular management mode to introduce different research and development mode to promote enterprise's competitiveness effectively.

  5. The outlook for advanced transport aircraft

    NASA Technical Reports Server (NTRS)

    Leavens, J. M., Jr.; Schaufele, R. D.; Jones, R. T.; Steiner, J. E.; Beteille, R.; Titcomb, G. A.; Coplin, J. F.; Rowe, B. H.; Lloyd-Jones, D. J.; Overend, W. J.

    1982-01-01

    The technological advances most likely to contribute to advanced aircraft designs and the efficiency, performance, and financial considerations driving the development directions for new aircraft are reviewed. Fuel-efficiency is perceived as the most critical factor for any new aircraft or component design, with most gains expected to come in areas of propulsion, aerodynamics, configurations, structural designs and materials, active controls, digital avionics, laminar flow control, and air-traffic control improvements. Any component area offers an efficiency improvement of 3-12%, with a maximum of 50% possible with a 4000 m range aircraft. Advanced turboprops have potential applications in short and medium haul subsonic aircraft, while a fuel efficient SST may be possible by the year 2000. Further discussion is devoted to the pivoted oblique wing aircraft, lightweight structures, and the necessity for short payback times.

  6. Optimal design and operation of solid oxide fuel cell systems for small-scale stationary applications

    NASA Astrophysics Data System (ADS)

    Braun, Robert Joseph

    The advent of maturing fuel cell technologies presents an opportunity to achieve significant improvements in energy conversion efficiencies at many scales; thereby, simultaneously extending our finite resources and reducing "harmful" energy-related emissions to levels well below that of near-future regulatory standards. However, before realization of the advantages of fuel cells can take place, systems-level design issues regarding their application must be addressed. Using modeling and simulation, the present work offers optimal system design and operation strategies for stationary solid oxide fuel cell systems applied to single-family detached dwellings. A one-dimensional, steady-state finite-difference model of a solid oxide fuel cell (SOFC) is generated and verified against other mathematical SOFC models in the literature. Fuel cell system balance-of-plant components and costs are also modeled and used to provide an estimate of system capital and life cycle costs. The models are used to evaluate optimal cell-stack power output, the impact of cell operating and design parameters, fuel type, thermal energy recovery, system process design, and operating strategy on overall system energetic and economic performance. Optimal cell design voltage, fuel utilization, and operating temperature parameters are found using minimization of the life cycle costs. System design evaluations reveal that hydrogen-fueled SOFC systems demonstrate lower system efficiencies than methane-fueled systems. The use of recycled cell exhaust gases in process design in the stack periphery are found to produce the highest system electric and cogeneration efficiencies while achieving the lowest capital costs. Annual simulations reveal that efficiencies of 45% electric (LHV basis), 85% cogenerative, and simple economic paybacks of 5--8 years are feasible for 1--2 kW SOFC systems in residential-scale applications. Design guidelines that offer additional suggestions related to fuel cell-stack sizing and operating strategy (base-load or load-following and cogeneration or electric-only) are also presented.

  7. The Decompression Sickness and Venous Gas Emboli Consequences of Air Breaks During 100% Oxygen Prebreathe

    NASA Technical Reports Server (NTRS)

    Conkin, J.; Gernhardt, M. L.; Powell, M. R.

    2004-01-01

    Not enough is known about the increased risk of hypobaric decompression sickness (DCS) and production of venous (VGE) and arterial (AGE) gas emboli following an air break in an otherwise normal 100% resting oxygen (O2) prebreathe (PB), and certainly a break in PB when exercise is used to accelerate nitrogen (N2) elimination from the tissues. Current Aeromedical Flight Rules at the Johnson Space Center about additional PB payback times are untested, possibly too conservative, and therefore not optimized for operational use. A 10 min air break at 90 min into a 120 min PB that includes initial dual-cycle ergometry for 10 min will show a measurable increase in the risk of DCS and VGE after ascent to 4.3 psia compared to a 10 min break at 15 min into the PB, or when there is no break in PB. Data collection with humans begins in 2005, but here we first evaluate the hypothesis using three models of tissue N2 kinetics: Model I is a simple single half-time compartment exponential model, Model II is a three compartment half-time exponential model, and Model III is a variable half-time compartment model where the percentage of maximum O2 consumption for the subject during dual-cycle ergometry exercise defines the half-time compartment. Model I with large rate constants to simulate an exercise effect always showed a late break in PB had the greatest consequence. Model II showed an early break had the greatest consequence. Model III showed there was no difference between early or late break in exercise PB. Only one of these outcomes will be observed when humans are tested. Our results will favor one of these models, and so advance our understanding of tissue N2 kinetics, and of altitude DCS after an air break in PB.

  8. Cooler Tile-Roofed Buildings with Near-Infrared-ReflectiveNon-white Coatings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levinson, Ronnen; Akbari, Hashem; Reilly, Joeseph C.

    Owners of homes with pitched roofs visible from ground leveloften prefer non-white roofing products for aesthetic considerations.Non-white, near-infrared-reflective architectural coatings can be appliedin-situ to pitched concrete or clay tile roofs to reduce tiletemperature, building heat gain, and cooling power demand, whilesimultaneously improving the roof s appearance. Scale model measurementsof building temperatures and heat-flux were combined with solar andcooling energy use data to estimate the effects of such cool roofcoatings in various California data. Under typical conditions e.g., 1 kWm-2 summer afternoon insolation, R-11 attic insulation, no radiantbarrier, and a 0.3 reduction in solar absorptance absolute reductions inroof surface temperature, atticmore » air temperature, and ceiling heat fluxare about 12 K, 6.2 K, and 3.7 W m-2, respectively. For a typical 1,500ft2 (139 m2) house with R-11 attic insulation and no radiant barrier,reducing roof absorptance by 0.3 yields whole-house peak power savings of230, 210, and 210 W in Fresno, San Bernardino, and San Diego,respectively. The corresponding absolute and fractional cooling energysavings are 92 kWh yr-1 (5 percent), 67 kWh yr-1 (6 percent), and 8 kWhyr-1 (1 percent), respectively. These savings are about half thosepreviously reported for houses with non-tile roofs. With theseassumptions, the statewide peak cooling power and annual cooling energyreductions would be 240 MW and 63 GWh yr-1, respectively. These energysavings would reduce annual emissions from California power plants by 35kilotonnes CO2, 11 tonnes NOx,and 0.86 tonnes SOx. The economic value ofcooling energy savings is well below the cost of coating a tile roof, butthe simple payback times for using cool pigments in a rooftile coatingare modest (5-7 years) in the hot climates of Fresno and SanBernardino.« less

  9. Cost-Benefit Analysis of Telemedicine Systems/Units in Greek Remote Areas.

    PubMed

    Kouskoukis, Marios-Nikolaos; Botsaris, Charalambos

    2017-06-01

    Telemedicine units and information technology systems provide special healthcare services to remote populations using telecommunication technology, in order to reduce or even remove the usual and typical face-to-face contact between doctor and patient. This innovative approach to medical care delivery has been expanding for several years and currently covers various medical specialties. To facilitate installation of telemedicine systems/units in Greek remote areas, this article presents results of a cost-benefit analysis for two Greek islands, Patmos and Leros, using specific economic criteria. Net present value (NPV), internal rate of return (IRR), and payback period were calculated, in order to monetize the economic benefits and the costs savings, estimate the depreciation of each project, and highlight the social benefits. Costs were reduced (through saved air medical transportations) by €19,005 for Patmos and €78,225 for Leros each year. NPV and IRR were positive; NPV was €29,608 for Patmos and €293,245 for Leros, and IRR was 21.5% for Patmos and 140.5% for Leros. Each project depreciated faster than the 5-year life-cycle period, and specifically in 3.13 years for Patmos and in 0.70 years for Leros. The establishment of telemedicine systems/units in Patmos and Leros was evaluated and assessed positively, with large savings, economical and social, gained by reducing or even removing the face-to-face contact between doctor and patient. Telemedicine systems/units seem to be a promising solution, especially in Greece, where the problem of primary healthcare services in remote/inaccessible areas is of great concern.

  10. Airplane Stress Analysis

    NASA Technical Reports Server (NTRS)

    Zahm, A F; Crook, L H

    1918-01-01

    Report presents stress analysis of individual components of an airplane. Normal and abnormal loads, sudden loads, simple stresses, indirect simple stresses, resultant unit stress, repetitive and equivalent stress, maximum steady load and stress are considered.

  11. Laboratory automation: trajectory, technology, and tactics.

    PubMed

    Markin, R S; Whalen, S A

    2000-05-01

    Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a modular approach, from a hardware-driven system to process control, from a one-of-a-kind novelty toward a standardized product, and from an in vitro diagnostics novelty to a marketing tool. Multiple vendors are present in the marketplace, many of whom are in vitro diagnostics manufacturers providing an automation solution coupled with their instruments, whereas others are focused automation companies. Automation technology continues to advance, acceptance continues to climb, and payback and cost justification methods are developing.

  12. Potential of Micro Hydroelectric Generator Embedded at 30,000 PE Effluent Discharge of Sewerage Treatment Plant

    NASA Astrophysics Data System (ADS)

    Che Munaaim, M. A.; Razali, N.; Ayob, A.; Hamidin, N.; Othuman Mydin, M. A.

    2018-03-01

    A micro hydroelectric generator is an energy conversion approach to generate electricity from potential (motion) energy to an electrical energy. In this research, it is desired to be implemented by using a micro hydroelectric generator which is desired to be embedded at the continuous flow of effluent discharge point of domestic sewerage treatment plant (STP). This research evaluates the potential of electricity generation from micro hydroelectric generator attached to 30,000 PE sewerage treatment plant. The power output obtained from calculation of electrical power conversion is used to identify the possibility of this system and its ability to provide electrical energy, which can minimize the cost of electric bill especially for the pumping system. The overview of this system on the practical application with the consideration of payback period is summarized. The ultimate aim of the whole application is to have a self-ecosystem electrical power generated for the internal use of STP by using its own flowing water in supporting the sustainable engineering towards renewable energy and energy efficient approach. The results shows that the output power obtained is lower than expected output power (12 kW) and fall beyond of the range of a micro hydro power (5kW - 100kW) since it is only generating 1.58 kW energy by calculation. It is also observed that the estimated payback period is longer which i.e 7 years to recoup the return of investment. A range of head from 4.5 m and above for the case where the flow shall at least have maintained at 0.05 m3/s in the selected plant in order to achieved a feasible power output. In conclusion, wastewater treatment process involves the flowing water (potential energy) especially at the effluent discharge point of STP is possibly harvested for electricity generation by embedding the micro hydroelectric generator. However, the selection of STP needs to have minimum 4.5 meter head with 0.05 m3/s of continuously flowing water to make it feasible to harvest.

  13. Measuring research impact: a large cancer research funding programme in Australia.

    PubMed

    Bowden, Jacqueline A; Sargent, Nicole; Wesselingh, Steve; Size, Lincoln; Donovan, Claire; Miller, Caroline L

    2018-05-09

    Measuring research impact is of critical interest to philanthropic and government funding agencies interested in ensuring that the research they fund is both scientifically excellent and has meaningful impact into health and other outcomes. The Beat Cancer Project (BCP) is a AUD $34 m cancer research funding scheme that commenced in 2011. It was initiated by an Australian charity (Cancer Council SA), and supported by the South Australian Government and the state's major universities. This study applied Buxton and Hanney's Payback Framework to assess research impact generated from the BCP after 3 years of funding. Data sources were an audit of peer-reviewed publications from January 2011 to September 2014 from Web of Knowledge and a self-report survey of investigators awarded BCP research funding during its first 3 years of implementation (2011-2013). Of the 104 surveys, 92 (88%) were completed. The BCP performed well across all five categories of the Payback Framework. In terms of knowledge production, 1257 peer-reviewed publications were generated and the mean impact factor of publishing journals increased annually. There were many benefits to future research with 21 respondents (23%) reporting career advancement, and 110 higher degrees obtained or expected (including 84 PhDs). Overall, 52% of funded projects generated tools for future research. The funded research attracted substantial further income yielding a very high rate of leverage. For every AUD $1 that the cancer charity invested, the BCP gained an additional AUD $6.06. Five projects (5%) had informed policy and 5 (5%) informed product development, with an additional 31 (34%) and 35 (38%) projects, respectively, anticipating doing so. In terms of health and sector and broader economic benefits, 8 (9%) projects had influenced practice or behaviour of health staff and 32 (34%) would reportedly to do so in the future. Research impact was a priority of charity and government funders and led to a deliberate funding strategy. Emphasising research impact while maintaining rigorous, competitive processes can achieve the joint objectives of excellence in research, yielding good research impact and a high rate of leverage for philanthropic and public investment, as indicated by these early results.

  14. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    ERIC Educational Resources Information Center

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  15. A Simple Exact Error Rate Analysis for DS-CDMA with Arbitrary Pulse Shape in Flat Nakagami Fading

    NASA Astrophysics Data System (ADS)

    Rahman, Mohammad Azizur; Sasaki, Shigenobu; Kikuchi, Hisakazu; Harada, Hiroshi; Kato, Shuzo

    A simple exact error rate analysis is presented for random binary direct sequence code division multiple access (DS-CDMA) considering a general pulse shape and flat Nakagami fading channel. First of all, a simple model is developed for the multiple access interference (MAI). Based on this, a simple exact expression of the characteristic function (CF) of MAI is developed in a straight forward manner. Finally, an exact expression of error rate is obtained following the CF method of error rate analysis. The exact error rate so obtained can be much easily evaluated as compared to the only reliable approximate error rate expression currently available, which is based on the Improved Gaussian Approximation (IGA).

  16. M13-Tailed Simple Sequence Repeat (SSR) Markers in Studies of Genetic Diversity and Population Structure of Common Oat Germplasm.

    PubMed

    Onyśk, Agnieszka; Boczkowska, Maja

    2017-01-01

    Simple Sequence Repeat (SSR) markers are one of the most frequently used molecular markers in studies of crop diversity and population structure. This is due to their uniform distribution in the genome, the high polymorphism, reproducibility, and codominant character. Additional advantages are the possibility of automatic analysis and simple interpretation of the results. The M13 tagged PCR reaction significantly reduces the costs of analysis by the automatic genetic analyzers. Here, we also disclose a short protocol of SSR data analysis.

  17. Life Cycle Analysis for the Feasibility of Photovoltaic System Application in Indonesia

    NASA Astrophysics Data System (ADS)

    Yudha, H. M.; Dewi, T.; Risma, P.; Oktarina, Y.

    2018-03-01

    Electricity has become the basic need for everyone, from industry to domestic. Today electricity source still depends heavily on fossil fuels that soon will be diminished from the earth in around 50 years. This condition demands us to find the renewable energy to support our everyday life. One of the famous renewable energy sources is from solar, harnessed by energy conversion device named solar cells. Countries like Indonesia are gifted with an abundance of sunlight all the yearlong. The application of solar cells with its photovoltaic (PV) technology harnesses the sunlight and converts it into electricity. Although this technology is emerging very fast, it still has some limitation due to the current PV technology, economic feasibility, and its environmental impacts. Life cycle assessment is the method to analyze and evaluate the sustainability of PV system and its environmental impact. This paper presents literature study of PV system from the cradle to grave, it begins with the material choices (from the first generation and the possibility of the fourth generation), manufacturing process, implementation, and ends it with the after-life effect of PV modules. The result of this study will be the insights look of the PV system application in Indonesia, from the best option of material choice, the best method of application, the energy payback time, and finally the possible after life recycle of PV materials.

  18. [Persistence of social representation regarding breast cancer].

    PubMed

    Giraldo-Mora, Clara V

    2009-08-01

    Understanding the social representation of breast cancer and how it has influenced breast cancer prevention and self-care practice in a group of women from the city of Medellin. This was a qualitative study using 19 semi-structured interviews with adult females who had not had breast cancer, using maximum variation criterion as sampling technique. The analysis was orientated by grounded theory. Some women physiologically represented breast cancer while others represented it by its social and psychological effects. They identified its causes with personal and emotional problems and certain daily habits such as inadequate food ("a bodily payback for the abuses which we subject ourselves to"). The word "breast cancer" was associated with inevitable death, terror, suffering, incurability, devastation, powerlessness and pain. This cancer has strong social representation due to its severe implications for females, their attractiveness and self-image. The persistence of breast cancer's negative image is associated with "the life-style myth" (1) for which people tend to blame the patient. Our biological reductionism hides environmental, social and political factors. We are obsessed by the dangers and their control (2) and powerful images are added to these messages such as those in which "one out of nine women will develop breast cancer" to foster self-responsibility (2). However, the ghost of cancer in developing societies in which many people are still trapped is magnified and has also yet to be overcome.

  19. Process for the recycling of alkaline and zinc-carbon spent batteries

    NASA Astrophysics Data System (ADS)

    Ferella, Francesco; De Michelis, Ida; Vegliò, Francesco

    In this paper a recycling process for the recovery of zinc and manganese from spent alkaline and zinc-carbon batteries is proposed. Laboratory tests are performed to obtain a purified pregnant solution from which metallic zinc (purity 99.6%) can be recovered by electrolysis; manganese is recovered as a mixture of oxides by roasting of solid residue coming from the leaching stage. Nearly 99% of zinc and 20% of manganese are extracted after 3 h, at 80 °C with 10% w/v pulp density and 1.5 M sulphuric acid concentration. The leach liquor is purified by a selective precipitation of iron, whereas metallic impurities, such as copper, nickel and cadmium are removed by cementation with zinc powder. The solid residue of leaching is roasted for 30 min at 900 °C, removing graphite completely and obtaining a mixture of Mn 3O 4 and Mn 2O 3 with 70% grade of Mn. After that a technical-economic assessment is carried out for a recycling plant with a feed capacity of 5000 t y -1 of only alkaline and zinc-carbon batteries. This analysis shows the economic feasibility of that plant, supposing a battery price surcharge of 0.5 € kg -1, with a return on investment of 34.5%, gross margin of 35.8% and around 3 years payback time.

  20. Evaluation of empowerment program to increase production capacity of fishery processing business in Semarang City, Indonesia

    NASA Astrophysics Data System (ADS)

    Swastawati, F.; Roessali, W.; Wijayanti, I.; Anggo, A. D.

    2018-01-01

    This study aims to evaluate the empowerment program to increase the production capacity of fishery product processing. Empowerment program was the implementation and utilization of science and technology in the area (IPTEKDA) LIPI Indonesia for Higher Education. Activity carried out in 2016 on fish processing industry “Lumintu Group”. Implementation of activities includes the transfer of technology to increase production capacity, business capital assistance in the form of production equipment, production assistance, and business management. This study uses qualitative, descriptive analysis, data collection with observation, interviews, and questionnaires. The results showed that the total number of active members was 24 people, 50% of the members specially cultivated the smoked fish that is the type of Catfish (Arius thalassinus) and Stingray (Dasyatis sp), while 45.83% of members processed boneless milkfish, and 4,17% produce salted fish. Increased average production scale of 31.82% in smoked fish business, 12.4% in boneless milkfish and 38.89% in salted fish business. Willingness to return capital in the good category, meaning that all members were able to carry out the schedule of relative payback on time. Approximately 83.3% of the group members felt that the program that followed had greatly assisted in increasing the scale of business but hoped to improve skills in terms of processing and marketing.

  1. Grid-connected distributed solar power systems

    NASA Astrophysics Data System (ADS)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  2. Status of Goldstone solar energy system study of the first Goldstone energy project

    NASA Technical Reports Server (NTRS)

    Lansing, F. L.

    1977-01-01

    The results reached by the DSN engineering section and private consultants in the review of the initial plan of the Golstone Energy Project are summarized. The main objectives were in the areas of energy conservation and the application of solar-driven systems for power and hydrogen generation. This summary will provide background data for management planning decisions both to the DSN engineering section and other organizations planning a similar program. The review showed that an add-on solar driven absorption refrigeration unit with its associated changes to the existing system was not cost-effective, having a payback period of 29 years. Similar economically unattractive results were found for both a solar-hydrogen and a wind-hydrogen generation plant. However, cutting the hydrogen generation linkage from this plant improved its economic feasibility.

  3. Interpersonal team leadership skills.

    PubMed

    Nelson, M

    1995-05-01

    To say that a team leader's job is a tough one is certainly not saying enough. It is up to the team leader to manage a group of people to be individuals but yet work as a team. The team leader must keep the peace and yet create a revolution with this group all at the same time. The good leader will require a lot of education, training, and tons of practical application to be a success. The good news, however, is that the team leader's job is a rewarding one, one that they'll always feel good about if they do it right. How many of us get the opportunity to take a group of wonderful, thinking individual minds and pull from them ideas that a whole team can take to success? Yes, the job is indeed tough, but the paybacks are many.

  4. Automating the business office.

    PubMed

    Wright, M A

    1996-10-01

    To measure the success of automating the business office with electronic billing and document management systems, the hospital's original goals were reviewed: Had the number of FTEs been maintained or reduced: Yes--claims volume is up 58% over 6 years with a 22% reduction in FTEs (see Exhibit 3). Was the cost of maintaining the paper filing system reduced? Yes--and the cost saving from the hospital's document imaging system will allow a 4.4 year payback. Is better customer service being provided? Yes--online access to patient demographic and financial information has improved response time. Having met all its goals, North Kansas City Hospital considers the installation of both systems to have been complete success. The facility expects to continue expansion of the document management system into accounts payable, payroll, home health, and other document-intensive areas to achieve further cost savings in the future.

  5. Large solar arrays

    NASA Technical Reports Server (NTRS)

    Crabtree, W. L.

    1980-01-01

    A spectrophotovoltaic converter, a thermophotovoltaic converter, a cassegrainian concentrator, a large silicon cell blanket, and a high flux approach are among the concepts being investigated as part of the multihundred kW solar array program for reducing the cost of photovoltaic energy in space. These concepts involve a range of technology risks, the highest risk being represented by the thermophotovoltaics and spectrophotovoltaics approaches which involve manipulation to of the incoming spectrum to enhance system efficiency. The planar array (solar blanket) has no technology risk and a moderate payback. The primary characteristics, components, and technology concerns of each of these concepts are summarized. An orbital power platform mission in the late 1980's is being used to allow a coherent technology advancement program in order to achieve a ten year life with maintenance at a capital recurring cost of $30/watt based on 1978 dollars.

  6. Simple Levelized Cost of Energy (LCOE) Calculator Documentation | Energy

    Science.gov Websites

    Analysis | NREL Simple Levelized Cost of Energy (LCOE) Calculator Documentation Simple Levelized Cost of Energy (LCOE) Calculator Documentation Transparent Cost Database Button This is a simple : 1). Cost and Performance Adjust the sliders to suitable values for each of the cost and performance

  7. Analysis of pre-service physics teacher skills designing simple physics experiments based technology

    NASA Astrophysics Data System (ADS)

    Susilawati; Huda, C.; Kurniawan, W.; Masturi; Khoiri, N.

    2018-03-01

    Pre-service physics teacher skill in designing simple experiment set is very important in adding understanding of student concept and practicing scientific skill in laboratory. This study describes the skills of physics students in designing simple experiments based technologicall. The experimental design stages include simple tool design and sensor modification. The research method used is descriptive method with the number of research samples 25 students and 5 variations of simple physics experimental design. Based on the results of interviews and observations obtained the results of pre-service physics teacher skill analysis in designing simple experimental physics charged technology is good. Based on observation result, pre-service physics teacher skill in designing simple experiment is good while modification and sensor application are still not good. This suggests that pre-service physics teacher still need a lot of practice and do experiments in designing physics experiments using sensor modifications. Based on the interview result, it is found that students have high enough motivation to perform laboratory activities actively and students have high curiosity to be skilled at making simple practicum tool for physics experiment.

  8. Constellation Coverage Analysis

    NASA Technical Reports Server (NTRS)

    Lo, Martin W. (Compiler)

    1997-01-01

    The design of satellite constellations requires an understanding of the dynamic global coverage provided by the constellations. Even for a small constellation with a simple circular orbit propagator, the combinatorial nature of the analysis frequently renders the problem intractable. Particularly for the initial design phase where the orbital parameters are still fluid and undetermined, the coverage information is crucial to evaluate the performance of the constellation design. We have developed a fast and simple algorithm for determining the global constellation coverage dynamically using image processing techniques. This approach provides a fast, powerful and simple method for the analysis of global constellation coverage.

  9. Phasor Analysis of Binary Diffraction Gratings with Different Fill Factors

    ERIC Educational Resources Information Center

    Martinez, Antonio; Sanchez-Lopez, Ma del Mar; Moreno, Ignacio

    2007-01-01

    In this work, we present a simple analysis of binary diffraction gratings with different slit widths relative to the grating period. The analysis is based on a simple phasor technique directly derived from the Huygens principle. By introducing a slit phasor and a grating phasor, the intensity of the diffracted orders and the grating's resolving…

  10. Behavior related pauses in simple spike activity of mouse Purkinje cells are linked to spike rate modulation

    PubMed Central

    Cao, Ying; Maran, Selva K.; Dhamala, Mukesh; Jaeger, Dieter; Heck, Detlef H.

    2012-01-01

    Purkinje cells (PCs) in the mammalian cerebellum express high frequency spontaneous activity with average spike rates between 30 and 200 Hz. Cerebellar nuclear (CN) neurons receive converging input from many PCs resulting in a continuous barrage of inhibitory inputs. It has been hypothesized that pauses in PC activity trigger increases in CN spiking activity. A prediction derived from this hypothesis is that pauses in PC simple spike activity represent relevant behavioral or sensory events. Here we asked whether pauses in the simple spike activity of PCs related to either fluid licking or respiration, play a special role in representing information about behavior. Both behaviors are widely represented in cerebellar PC simple spike activity. We recorded PC activity in the vermis and lobus simplex of head fixed mice while monitoring licking and respiratory behavior. Using cross correlation and Granger causality analysis we examined whether short ISIs had a different temporal relation to behavior than long ISIs or pauses. Behavior related simple spike pauses occurred during low-rate simple spike activity in both licking and breathing related PCs. Granger causality analysis revealed causal relationships between simple spike pauses and behavior. However, the same results were obtained from an analysis of surrogate spike trains with gamma ISI distributions constructed to match rate modulations of behavior related Purkinje cells. Our results therefore suggest that the occurrence of pauses in simple spike activity does not represent additional information about behavioral or sensory events that goes beyond the simple spike rate modulations. PMID:22723707

  11. Simple Spreadsheet Models For Interpretation Of Fractured Media Tracer Tests

    EPA Science Inventory

    An analysis of a gas-phase partitioning tracer test conducted through fractured media is discussed within this paper. The analysis employed matching eight simple mathematical models to the experimental data to determine transport parameters. All of the models tested; two porous...

  12. Validation of the Simple Shoulder Test in a Portuguese-Brazilian population. Is the latent variable structure and validation of the Simple Shoulder Test Stable across cultures?

    PubMed

    Neto, Jose Osni Bruggemann; Gesser, Rafael Lehmkuhl; Steglich, Valdir; Bonilauri Ferreira, Ana Paula; Gandhi, Mihir; Vissoci, João Ricardo Nickenig; Pietrobon, Ricardo

    2013-01-01

    The validation of widely used scales facilitates the comparison across international patient samples. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. The Simple Shoulder Test was translated from English into Brazilian Portuguese, translated back into English, and evaluated for accuracy by an expert committee. It was then administered to 100 patients with shoulder conditions. Psychometric properties were analyzed including factor analysis, internal reliability, test-retest reliability at seven days, and construct validity in relation to the Short Form 36 health survey (SF-36). Factor analysis demonstrated a three factor solution. Cronbach's alpha was 0.82. Test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.84. Associations were observed in the hypothesized direction with all subscales of SF-36 questionnaire. The Simple Shoulder Test translation and cultural adaptation to Brazilian-Portuguese demonstrated adequate factor structure, internal reliability, and validity, ultimately allowing for its use in the comparison with international patient samples.

  13. Validation of the Simple Shoulder Test in a Portuguese-Brazilian Population. Is the Latent Variable Structure and Validation of the Simple Shoulder Test Stable across Cultures?

    PubMed Central

    Neto, Jose Osni Bruggemann; Gesser, Rafael Lehmkuhl; Steglich, Valdir; Bonilauri Ferreira, Ana Paula; Gandhi, Mihir; Vissoci, João Ricardo Nickenig; Pietrobon, Ricardo

    2013-01-01

    Background The validation of widely used scales facilitates the comparison across international patient samples. The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. Objective The objective of this study was to translate, culturally adapt and validate the Simple Shoulder Test into Brazilian Portuguese. Also we test the stability of factor analysis across different cultures. Methods The Simple Shoulder Test was translated from English into Brazilian Portuguese, translated back into English, and evaluated for accuracy by an expert committee. It was then administered to 100 patients with shoulder conditions. Psychometric properties were analyzed including factor analysis, internal reliability, test-retest reliability at seven days, and construct validity in relation to the Short Form 36 health survey (SF-36). Results Factor analysis demonstrated a three factor solution. Cronbach’s alpha was 0.82. Test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.84. Associations were observed in the hypothesized direction with all subscales of SF-36 questionnaire. Conclusion The Simple Shoulder Test translation and cultural adaptation to Brazilian-Portuguese demonstrated adequate factor structure, internal reliability, and validity, ultimately allowing for its use in the comparison with international patient samples. PMID:23675436

  14. [Analysis on the accuracy of simple selection method of Fengshi (GB 31)].

    PubMed

    Li, Zhixing; Zhang, Haihua; Li, Suhe

    2015-12-01

    To explore the accuracy of simple selection method of Fengshi (GB 31). Through the study of the ancient and modern data,the analysis and integration of the acupuncture books,the comparison of the locations of Fengshi (GB 31) by doctors from all dynasties and the integration of modern anatomia, the modern simple selection method of Fengshi (GB 31) is definite, which is the same as the traditional way. It is believed that the simple selec tion method is in accord with the human-oriented thought of TCM. Treatment by acupoints should be based on the emerging nature and the individual difference of patients. Also, it is proposed that Fengshi (GB 31) should be located through the integration between the simple method and body surface anatomical mark.

  15. A Simple Plant Growth Analysis.

    ERIC Educational Resources Information Center

    Oxlade, E.

    1985-01-01

    Describes the analysis of dandelion peduncle growth based on peduncle length, epidermal cell dimensions, and fresh/dry mass. Methods are simple and require no special apparatus or materials. Suggests that limited practical work in this area may contribute to students' lack of knowledge on plant growth. (Author/DH)

  16. Different leaf cost-benefit strategies of ferns distributed in contrasting light habitats of sub-tropical forests.

    PubMed

    Zhu, Shi-Dan; Li, Rong-Hua; Song, Juan; He, Peng-Cheng; Liu, Hui; Berninger, Frank; Ye, Qing

    2016-03-01

    Ferns are abundant in sub-tropical forests in southern China, with some species being restricted to shaded understorey of natural forests, while others are widespread in disturbed, open habitats. To explain this distribution pattern, we hypothesize that ferns that occur in disturbed forests (FDF) have a different leaf cost-benefit strategy compared with ferns that occur in natural forests (FNF), with a quicker return on carbon investment in disturbed habitats compared with old-growth forests. We chose 16 fern species from contrasting light habitats (eight FDF and eight FNF) and studied leaf functional traits, including leaf life span (LLS), specific leaf area (SLA), leaf nitrogen and phosphorus concentrations (N and P), maximum net photosynthetic rates (A), leaf construction cost (CC) and payback time (PBT), to conduct a leaf cost-benefit analysis for the two fern groups. The two groups, FDF and FNF, did not differ significantly in SLA, leaf N and P, and CC, but FDF had significantly higher A, greater photosynthetic nitrogen- and phosphorus-use efficiencies (PNUE and PPUE), and shorter PBT and LLS compared with FNF. Further, across the 16 fern species, LLS was significantly correlated with A, PNUE, PPUE and PBT, but not with SLA and CC. Our results demonstrate that leaf cost-benefit analysis contributes to understanding the distribution pattern of ferns in contrasting light habitats of sub-tropical forests: FDF employing a quick-return strategy can pre-empt resources and rapidly grow in the high-resource environment of open habitats; while a slow-return strategy in FNF allows their persistence in the shaded understorey of old-growth forests. © The Author 2015. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Demand response-enabled model predictive HVAC load control in buildings using real-time electricity pricing

    NASA Astrophysics Data System (ADS)

    Avci, Mesut

    A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy is built based on a proposed model that jointly minimizes the total energy consumption and hence, cost of electricity for the user, and the deviation of the inside temperature from the consumer's preference. An algorithm that assigns temperature set-points (reference temperatures) to price ranges based on the consumer's discomfort tolerance index is developed. A practical parameter prediction model is also designed for mapping between the HVAC load and the inside temperature. The prediction model and the produced temperature set-points are integrated as inputs into the MPC controller, which is then used to generate signal actions for the AC unit. To investigate and demonstrate the effectiveness of the proposed approach, a simulation based experimental analysis is presented using real-life pricing data. An actual prototype for the proposed HVAC load control strategy is then built and a series of prototype experiments are conducted similar to the simulation studies. The experiments reveal that the MPC strategy can lead to significant reductions in overall energy consumption and cost savings for the consumer. Results suggest that by providing an efficient response strategy for the consumers, the proposed MPC strategy can enable the utility providers to adopt efficient demand management policies using real-time pricing. Finally, a cost-benefit analysis is performed to display the economic feasibility of implementing such a controller as part of a building energy management system, and the payback period is identified considering cost of prototype build and cost savings to help the adoption of this controller in the building HVAC control industry.

  18. Development of Rice Reprocessing to Strengthen Small Scale Rice Mills in Indramayu West Java

    NASA Astrophysics Data System (ADS)

    Firdaus, Y. R.; Hasbullah, R.; Djohar, S.

    2018-05-01

    Small Rice Mill (SRM) has a very important role in rice production of strong institutional relationships to farmers and rice markets. Nevertheless, the rice produced in low quality and changing consumer preferences cause SRM to have difficulty in maintaining the role. Development of a reprocessing business - called Rice to Rice Processing Plant (R2RP) - as a separate business unit will support their role and existence. This study aimed at analyzing the feasibility of R2RP business that integrates SRM and market as an independent business unit and determines mutual partnership pattern. The study was conducted with special reference to West Java Province. The qualitative method used for non-financial aspects analysis includes raw material, market, technical-technological, management and regulation and partnership pattern. The financial aspect used the quantitative method of Net Present Value (NPV), Net Benefit Cost Ratio (Net B/C), Internal Rate of Return (IRR), Payback Period (PP) and Switching Value to check their sensitivity.The results showed R2R business is feasible for non-financially, technical-technological and financial aspects. Technology has evolved to produce various qualities (premium or medium) after the quality of raw materials (low quality or off-grade rice) using profit optimization. Value of the financial parameters was NPV of Rp 137 billion, Net B/C of 5.80, IRR of 84.27 percent and PP of 2.18 years at capacity of 19,800 tons/year with total investment of Rp 30 billion (Rp 13,500/USD). The switching value analysis showed that a decrease in product prices is sensitively influencing the financial feasibility. To strengthen cooperation that enhancing mutually beneficial relationship, R2R assists equipment investment in and buy raw material from SRM at a rational agreed price.

  19. Different leaf cost–benefit strategies of ferns distributed in contrasting light habitats of sub-tropical forests

    PubMed Central

    Zhu, Shi-Dan; Li, Rong-Hua; Song, Juan; He, Peng-Cheng; Liu, Hui; Berninger, Frank; Ye, Qing

    2016-01-01

    Background and Aims Ferns are abundant in sub-tropical forests in southern China, with some species being restricted to shaded understorey of natural forests, while others are widespread in disturbed, open habitats. To explain this distribution pattern, we hypothesize that ferns that occur in disturbed forests (FDF) have a different leaf cost–benefit strategy compared with ferns that occur in natural forests (FNF), with a quicker return on carbon investment in disturbed habitats compared with old-growth forests. Methods We chose 16 fern species from contrasting light habitats (eight FDF and eight FNF) and studied leaf functional traits, including leaf life span (LLS), specific leaf area (SLA), leaf nitrogen and phosphorus concentrations (N and P), maximum net photosynthetic rates (A), leaf construction cost (CC) and payback time (PBT), to conduct a leaf cost–benefit analysis for the two fern groups. Key Results The two groups, FDF and FNF, did not differ significantly in SLA, leaf N and P, and CC, but FDF had significantly higher A, greater photosynthetic nitrogen- and phosphorus-use efficiencies (PNUE and PPUE), and shorter PBT and LLS compared with FNF. Further, across the 16 fern species, LLS was significantly correlated with A, PNUE, PPUE and PBT, but not with SLA and CC. Conclusions Our results demonstrate that leaf cost–benefit analysis contributes to understanding the distribution pattern of ferns in contrasting light habitats of sub-tropical forests: FDF employing a quick-return strategy can pre-empt resources and rapidly grow in the high-resource environment of open habitats; while a slow-return strategy in FNF allows their persistence in the shaded understorey of old-growth forests. PMID:26684751

  20. Electrical performance analysis and economic evaluation of combined biomass cook stove thermoelectric (BITE) generator.

    PubMed

    Lertsatitthanakorn, C

    2007-05-01

    The use of biomass cook stoves is widespread in the domestic sector of developing countries, but the stoves are not efficient. To advance the versatility of the cook stove, we investigated the feasibility of adding a commercial thermoelectric (TE) module made of bismuth-telluride based materials to the stove's side wall, thereby creating a thermoelectric generator system that utilizes a proportion of the stove's waste heat. The system, a biomass cook stove thermoelectric generator (BITE), consists of a commercial TE module (Taihuaxing model TEP1-1264-3.4), a metal sheet wall which acts as one side of the stove's structure and serves as the hot side of the TE module, and a rectangular fin heat sink at the cold side of the TE module. An experimental set-up was built to evaluate the conversion efficiency at various temperature ranges. The experimental set-up revealed that the electrical power output and the conversion efficiency depended on the temperature difference between the cold and hot sides of the TE module. At a temperature difference of approximately 150 degrees C, the unit achieved a power output of 2.4W. The conversion efficiency of 3.2% was enough to drive a low power incandescent light bulb or a small portable radio. A theoretical model approximated the power output at low temperature ranges. An economic analysis indicated that the payback period tends to be very short when compared with the cost of the same power supplied by batteries. Therefore, the generator design formulated here could be used in the domestic sector. The system is not intended to compete with primary power sources but serves adequately as an emergency or backup source of power.

  1. SimpleITK Image-Analysis Notebooks: a Collaborative Environment for Education and Reproducible Research.

    PubMed

    Yaniv, Ziv; Lowekamp, Bradley C; Johnson, Hans J; Beare, Richard

    2018-06-01

    Modern scientific endeavors increasingly require team collaborations to construct and interpret complex computational workflows. This work describes an image-analysis environment that supports the use of computational tools that facilitate reproducible research and support scientists with varying levels of software development skills. The Jupyter notebook web application is the basis of an environment that enables flexible, well-documented, and reproducible workflows via literate programming. Image-analysis software development is made accessible to scientists with varying levels of programming experience via the use of the SimpleITK toolkit, a simplified interface to the Insight Segmentation and Registration Toolkit. Additional features of the development environment include user friendly data sharing using online data repositories and a testing framework that facilitates code maintenance. SimpleITK provides a large number of examples illustrating educational and research-oriented image analysis workflows for free download from GitHub under an Apache 2.0 license: github.com/InsightSoftwareConsortium/SimpleITK-Notebooks .

  2. Interactions between Type of Instruction and Type of Language Feature: A Meta-Analysis

    ERIC Educational Resources Information Center

    Spada, Nina; Tomita, Yasuyo

    2010-01-01

    A meta-analysis was conducted to investigate the effects of explicit and implicit instruction on the acquisition of simple and complex grammatical features in English. The target features in the 41 studies contributing to the meta-analysis were categorized as simple or complex based on the number of criteria applied to arrive at the correct target…

  3. Summer Research Program - 1997 Summer Faculty Research Program Volume 6 Arnold Engineering Development Center United States Air Force Academy Air Logistics Centers

    DTIC Science & Technology

    1997-12-01

    Fracture Analysis of the F-5, 15%-Spar Bolt DR Devendra Kumar SAALC/LD 6- 16 CUNY-City College, New York, NY A Simple, Multiversion Concurrency Control...Program, University of Dayton, Dayton, OH. [3]AFGROW, Air Force Crack Propagation Analysis Program, Version 3.82 (1997) 15-8 A SIMPLE, MULTIVERSION ...Office of Scientific Research Boiling Air Force Base, DC and San Antonio Air Logistic Center August 1997 16-1 A SIMPLE, MULTIVERSION CONCURRENCY

  4. Fourier Spectroscopy: A Simple Analysis Technique

    ERIC Educational Resources Information Center

    Oelfke, William C.

    1975-01-01

    Presents a simple method of analysis in which the student can integrate, point by point, any interferogram to obtain its Fourier transform. The manual technique requires no special equipment and is based on relationships that most undergraduate physics students can derive from the Fourier integral equations. (Author/MLH)

  5. What's the bottom line payback for TQM?

    NASA Technical Reports Server (NTRS)

    Usilaner, Brian

    1992-01-01

    The purpose of this article is to explore in detail TQM's impact on improving organization performance and how effective TQM strategies are designed and implemented. Both of these issues are addressed primarily by a discussion of a recent study of TQM efforts conducted by the U.S. General Accounting Office (GAO). The GAO study examines the impact of formal TQM improvement strategies on the performance of selected U.S. companies. The study grew out of a concern by a number of U.S. Congressmen that little is known about the impact of various quality-related efforts many companies have adopted to remain viable and profitable in an increasingly competitive world marketplace. Specifically, the study addresses: what has been the performance impact of adopting TQM improvement strategies, how has improved quality been achieved, and what lessons may be applicable to U.S. companies in general. A number of other studies are also used to expand upon the GAO data.

  6. Enabling VOLTTRON: Energy Management of Commercial Buildings at the University of Maryland

    NASA Astrophysics Data System (ADS)

    Ebhojiaye, Itohan Omisi

    Buildings waste approximately 30% of energy they consume due to inefficient HVAC and lighting operation. Building Automation Systems (BAS) can aid in reducing such wasted energy, but 90% of U.S. commercial buildings lack a BAS due to their high capital costs. This thesis demonstrates how VOLTTRON, an open source operating system developed by Pacific Northwest National Laboratory, was used to disable the mechanical cooling of a rooftop unit (RTU) during unoccupied hours, on a building without a BAS. With cooling off, the RTU's electricity dropped from 18 kW to 7kW. These results indicate 450 to 550 can be saved on the monthly electric bill of the building during the summer, compared to when the RTU operated in cooling mode continuously. The installation cost of the equipment that enabled the RTU to be controlled via VOLTTRON was $6,400, thus the project has a payback period of 13 months.

  7. Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-09-01

    The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryersmore » used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  8. A graphics subsystem retrofit design for the bladed-disk data acquisition system. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Carney, R. R.

    1983-01-01

    A graphics subsystem retrofit design for the turbojet blade vibration data acquisition system is presented. The graphics subsystem will operate in two modes permitting the system operator to view blade vibrations on an oscilloscope type of display. The first mode is a real-time mode that displays only gross blade characteristics, such as maximum deflections and standing waves. This mode is used to aid the operator in determining when to collect detailed blade vibration data. The second mode of operation is a post-processing mode that will animate the actual blade vibrations using the detailed data collected on an earlier data collection run. The operator can vary the rate of payback to view differring characteristics of blade vibrations. The heart of the graphics subsystem is a modified version of AMD's ""super sixteen'' computer, called the graphics preprocessor computer (GPC). This computer is based on AMD's 2900 series of bit-slice components.

  9. Energy-environmental benefits and economic feasibility of anaerobic codigestion of Iberian pig slaughterhouse and tomato industry wastes in Extremadura (Spain).

    PubMed

    González-González, A; Cuadros, F; Ruiz-Celma, A; López-Rodríguez, F

    2013-05-01

    Anaerobic digestion of Iberian pig slaughterhouse and tomato industry wastes, as well as codigestion operations from such residues, are reported to achieve 54-80% reduction in Chemical Oxygen Demand and 6-19 N m(3)/m(3) substrate methane production. Furthermore, 0.79-0.88 m(3)water/m(3) substrate is seen to be recovered after the above mentioned operations, which might be used as irrigation water, and 0.12-0.21 m(3)agricultural amendment/m(3) substrate with 91-98% moisture content. The present paper also reports on the economic feasibility of both an anaerobic codigestion plant operating with 60% slaughterhouse wastes/40% tomato industry wastes (optimal ratio obtained in previous laboratory-scaled experiments), and an anaerobic digestion plant for Iberian pig slaughterhouse waste. Payback times are reported as 14.86 and 3.73 years, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. The business case for quality mental health services: why employers should care about the mental health and well-being of their employees.

    PubMed

    Goetzel, Ron Z; Ozminkowski, Ronald J; Sederer, Lloyd I; Mark, Tami L

    2002-04-01

    Employers are very concerned about rising mental health care costs. They want to know whether their health care spending is improving the health of workers, and whether there is a productivity payback from providing good mental health care. This article addresses the subject of employee depression and its impact on business. The literature suggests that depressed individuals exert a significant cost burden for employers. Evidence is mounting that worker depression may have its greatest impact on productivity losses, including increased absenteeism and short-term disability, higher turnover, and suboptimal performance at work. Although there is no conclusive evidence yet that physical health care costs decrease when depression is effectively treated, there is growing evidence that productivity improvements occur as a consequence of effective treatment, and those improvements may offset the cost of the treatment.

  11. Dye Sensitized Solar Cells for Economically Viable Photovoltaic Systems.

    PubMed

    Jung, Hyun Suk; Lee, Jung-Kun

    2013-05-16

    TiO2 nanoparticle-based dye sensitized solar cells (DSSCs) have attracted a significant level of scientific and technological interest for their potential as economically viable photovoltaic devices. While DSSCs have multiple benefits such as material abundance, a short energy payback period, constant power output, and compatibility with flexible applications, there are still several challenges that hold back large scale commercialization. Critical factors determining the future of DSSCs involve energy conversion efficiency, long-term stability, and production cost. Continuous advancement of their long-term stability suggests that state-of-the-art DSSCs will operate for over 20 years without a significant decrease in performance. Nevertheless, key questions remain in regards to energy conversion efficiency improvements and material cost reduction. In this Perspective, the present state of the field and the ongoing efforts to address the requirements of DSSCs are summarized with views on the future of DSSCs.

  12. Retribution as hierarchy regulation: Hierarchy preferences moderate the effect of offender socioeconomic status on support for retribution.

    PubMed

    Redford, Liz; Ratliff, Kate A

    2018-01-01

    People punish others for various reasons, including deterring future crime, incapacitating the offender, and retribution, or payback. The current research focuses on retribution, testing whether support for retribution is motivated by the desire to maintain social hierarchies. If so, then the retributive tendencies of hierarchy enhancers or hierarchy attenuators should depend on whether offenders are relatively lower or higher in status, respectively. Three studies showed that hierarchy attenuators were more retributive against high-status offenders than for low-status offenders, that hierarchy enhancers showed a stronger orientation towards retributive justice, and that relationship was stronger for low-status, rather than high-status, criminal offenders. These findings clarify the purpose and function of retributive punishment. They also reveal how hierarchy-regulating motives underlie retribution, motives which, if allowed to influence judgements, may contribute to biased or ineffective justice systems. © 2017 The British Psychological Society.

  13. Steam bottoming cycle for an adiabatic diesel engine

    NASA Technical Reports Server (NTRS)

    Poulin, E.; Demier, R.; Krepchin, I.; Walker, D.

    1984-01-01

    Steam bottoming cycles using adiabatic diesel engine exhaust heat which projected substantial performance and economic benefits for long haul trucks were studied. Steam cycle and system component variables, system cost, size and performance were analyzed. An 811 K/6.90 MPa state of the art reciprocating expander steam system with a monotube boiler and radiator core condenser was selected for preliminary design. The costs of the diesel with bottoming system (TC/B) and a NASA specified turbocompound adiabatic diesel with aftercooling with the same total output were compared, the annual fuel savings less the added maintenance cost was determined to cover the increase initial cost of the TC/B system in a payback period of 2.3 years. Steam bottoming system freeze protection strategies were developed, technological advances required for improved system reliability are considered and the cost and performance of advanced systes are evaluated.

  14. Solarnorth '81 by Tymura Solardesigns: diverse residential, commercial and industrial projects at and above the 48th parallel in Ontario, Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tymura, E.J.

    1981-01-01

    Solar Energy Heating Applications are On the Rise in and above the Northwestern City of Thunder Bay, on the northern shore of Lake Superior. Unique in their diversifications, the architectural commissions range from pure passive residential design thru hybrid systems; residential Greenhouse-Solarium active swimming pool and commercial hotel pool to inexpensive hybrid system for Canada's First Commercial Solar Lumber Drying Kiln; as well as combined earth sheltered with solar system design for a dormitory complex and shopping center. By May 1981, 7 buildings designed by Tymura Solardesigns in the Thunder Bay area will have been subjected to the Extreme Canadianmore » climate (10,500/sup 0/F degree days, yearly temperature maximums from -41/sup 0/F to 90/sup 0/F, and solar fractions vary from 50% to 75%, with economic payback periods ranging between 7 and 10 years.« less

  15. Applications of power beaming from space-based nuclear power stations. [Laser beaming to airplanes; microwave beaming to ground

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, J.R.; Botts, T.E.; Hertzberg, A.

    1981-01-01

    Power beaming from space-based reactor systems is examined using an advanced compact, lightweight Rotating Bed Reactor (RBR). Closed Brayton power conversion efficiencies in the range of 30 to 40% can be achieved with turbines, with reactor exit temperatures on the order of 2000/sup 0/K and a liquid drop radiator to reject heat at temperatures of approx. 500/sup 0/K. Higher RBR coolant temperatures (up to approx. 3000/sup 0/K) are possible, but gains in power conversion efficiency are minimal, due to lower expander efficiency (e.g., a MHD generator). Two power beaming applications are examined - laser beaming to airplanes and microwave beamingmore » to fixed ground receivers. Use of the RBR greatly reduces system weight and cost, as compared to solar power sources. Payback times are a few years at present prices for power and airplane fuel.« less

  16. Overview of ground coupled heat pump research and technology transfer activities

    NASA Astrophysics Data System (ADS)

    Baxter, V. D.; Mei, V. C.

    Highlights of DOE-sponsored ground coupled heat pump (GCHP) research at Oak Ridge National Laboratory (ORNL) are presented. ORNL, in cooperation with Niagara Mohawk Power Company, Climate Master, Inc., and Brookhaven National Laboratory developed and demonstrated an advanced GCHP design concept with shorter ground coils that can reduce installed costs for northern climates. In these areas it can also enhance the competitiveness of GCHP systems versus air-source heat pumps by lowering their payback from 6 to 7 years to 3 to 5 years. Ground coil heat exchanger models (based primarily on first principles) have been developed and used by others to generate less conservative ground coil sizing methods. An aggressive technology transfer initiative was undertaken to publicize results of this research and make it available to the industry. Included in this effort were an international workshop, trade press releases and articles, and participation in a live teleconference on GCHP technology.

  17. Techno-economic evaluation of a combined bioprocess for fermentative hydrogen production from food waste.

    PubMed

    Han, Wei; Fang, Jun; Liu, Zhixiang; Tang, Junhong

    2016-02-01

    In this study, the techno-economic evaluation of a combined bioprocess based on solid state fermentation for fermentative hydrogen production from food waste was carried out. The hydrogen production plant was assumed to be built in Hangzhou and designed for converting 3 ton food waste per day into hydrogen. The total capital cost (TCC) and the annual production cost (APC) were US$583092 and US$88298.1/year, respectively. The overall revenue after the tax was US$146473.6/year. The return on investment (ROI), payback period (PBP) and internal rate of return (IRR) of the plant were 26.75%, 5 years and 24.07%, respectively. The results exhibited that the combined bioprocess for hydrogen production from food waste was feasible. This is an important study for attracting investment and industrialization interest for hydrogen production from food waste in the industrial scale. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. The solar power satellite concept - The past decade and the next decade

    NASA Technical Reports Server (NTRS)

    Kraft, C. C., Jr.

    1979-01-01

    Results of studies on the solar power satellite concept, currently under evaluation by NASA and the Department of Energy, are summarized. The basic advantages provided by the concept are the near-continuous access to sunlight and the freedom from atmospheric effects and cloud cover. The systems definition studies have considered photovoltaic and thermal energy conversion systems and found both to be technically feasible, with the photovoltaic approach being currently preferred. A microwave test program is under way which will provide quantitative data on critical parameters, including beam forming and steering accuracy. Ballistic and winged launch vehicles have been defined for the transportation of construction materials, with the Shuttle expected to provide low-cost transportation to and from space. A reference system has been outlined for evaluating the concept in terms of environmental and other considerations. Preliminary estimates of natural resource requirements and energy payback intervals are encouraging.

  19. What's the bottom line payback for TQM?

    NASA Astrophysics Data System (ADS)

    Usilaner, Brian

    The purpose of this article is to explore in detail TQM's impact on improving organization performance and how effective TQM strategies are designed and implemented. Both of these issues are addressed primarily by a discussion of a recent study of TQM efforts conducted by the U.S. General Accounting Office (GAO). The GAO study examines the impact of formal TQM improvement strategies on the performance of selected U.S. companies. The study grew out of a concern by a number of U.S. Congressmen that little is known about the impact of various quality-related efforts many companies have adopted to remain viable and profitable in an increasingly competitive world marketplace. Specifically, the study addresses: what has been the performance impact of adopting TQM improvement strategies, how has improved quality been achieved, and what lessons may be applicable to U.S. companies in general. A number of other studies are also used to expand upon the GAO data.

  20. Design and evaluation of fluidized bed heat recovery for diesel engine systems

    NASA Technical Reports Server (NTRS)

    Hamm, J. R.; Newby, R. A.; Vidt, E. J.; Lippert, T. E.

    1985-01-01

    The potential of utilizing fluidized bed heat exchangers in place of conventional counter-flow heat exchangers for heat recovery from adiabatic diesel engine exhaust gas streams was studied. Fluidized bed heat recovery systems were evaluated in three different heavy duty transport applications: (1) heavy duty diesel truck; (2) diesel locomotives; and (3) diesel marine pushboat. The three applications are characterized by differences in overall power output and annual utilization. For each application, the exhaust gas source is a turbocharged-adiabatic diesel core. Representative subposed exhaust gas heat utilization power cycles were selected for conceptual design efforts including design layouts and performance estimates for the fluidized bed heat recovery heat exchangers. The selected power cycles were: organic rankine with RC-1 working fluid, turbocompound power turbine with steam injection, and stirling engine. Fuel economy improvement predictions are used in conjunction with capital cost estimates and fuel price data to determine payback times for the various cases.

  1. Economic feasibility of solar water and space heating.

    PubMed

    Bezdek, R H; Hirshberg, A S; Babcock, W H

    1979-03-23

    The economic feasibility in 1977 and 1978 of solar water and combined water and space heating is analyzed for single-family detached residences and multi-family apartment buildings in four representative U.S. cities: Boston, Massachusetts; Washington, D.C.; Grand Junction, Colorado; and Los Angeles, California. Three economic decision criteria are utilized: payback period, years to recovery of down payment, and years to net positive cash flow. The cost competitiveness of the solar systems compared to heating systems based on electricity, fuel oil, and natural gas is then discussed for each city, and the impact of the federal tax credit for solar energy systems is assessed. It is found that even without federal incentives some solar water and space heating systems are competitive. Enactment of the solar tax credit, however, greatly enhances their competitiveness. The implications of these findings for government tax and energy pricing policies are discussed.

  2. Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yixing; Hong, Tianzhen; Piette, Mary Ann

    Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details ofmore » using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city's mild climate and minimal cooling and heating loads. Furthermore, the CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or technologies for the generation and simulation of building energy models, which helps overcome major technical barriers for city managers and their consultants to adopt UBEM.« less

  3. Automatic generation and simulation of urban building energy models based on city datasets for city-scale building retrofit analysis

    DOE PAGES

    Chen, Yixing; Hong, Tianzhen; Piette, Mary Ann

    2017-08-07

    Buildings in cities consume 30–70% of total primary energy, and improving building energy efficiency is one of the key strategies towards sustainable urbanization. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures (ECMs) for investment and the design of incentive and rebate programs. This paper presents the retrofit analysis feature of City Building Energy Saver (CityBES) to automatically generate and simulate UBEM using EnergyPlus based on cities’ building datasets and user-selected ECMs. CityBES is a new open web-based tool to support city-scale building energy efficiency strategic plans and programs. The technical details ofmore » using CityBES for UBEM generation and simulation are introduced, including the workflow, key assumptions, and major databases. Also presented is a case study that analyzes the potential retrofit energy use and energy cost savings of five individual ECMs and two measure packages for 940 office and retail buildings in six city districts in northeast San Francisco, United States. The results show that: (1) all five measures together can save 23–38% of site energy per building; (2) replacing lighting with light-emitting diode lamps and adding air economizers to existing heating, ventilation and air-conditioning (HVAC) systems are most cost-effective with an average payback of 2.0 and 4.3 years, respectively; and (3) it is not economical to upgrade HVAC systems or replace windows in San Francisco due to the city's mild climate and minimal cooling and heating loads. Furthermore, the CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or technologies for the generation and simulation of building energy models, which helps overcome major technical barriers for city managers and their consultants to adopt UBEM.« less

  4. A simple bias correction in linear regression for quantitative trait association under two-tail extreme selection.

    PubMed

    Kwan, Johnny S H; Kung, Annie W C; Sham, Pak C

    2011-09-01

    Selective genotyping can increase power in quantitative trait association. One example of selective genotyping is two-tail extreme selection, but simple linear regression analysis gives a biased genetic effect estimate. Here, we present a simple correction for the bias.

  5. Sensitive sub-Doppler nonlinear spectroscopy for hyperfine-structure analysis using simple atomizers

    NASA Astrophysics Data System (ADS)

    Mickadeit, Fritz K.; Kemp, Helen; Schafer, Julia; Tong, William M.

    1998-05-01

    Laser wave-mixing spectroscopy is presented as a sub-Doppler method that offers not only high spectral resolution, but also excellent detection sensitivity. It offers spectral resolution suitable for hyperfine structure analysis and isotope ratio measurements. In a non-planar backward- scattering four-wave mixing optical configuration, two of the three input beams counter propagate and the Doppler broadening is minimized, and hence, spectral resolution is enhanced. Since the signal is a coherent beam, optical collection is efficient and signal detection is convenient. This simple multi-photon nonlinear laser method offers un usually sensitive detection limits that are suitable for trace-concentration isotope analysis using a few different types of simple analytical atomizers. Reliable measurement of hyperfine structures allows effective determination of isotope ratios for chemical analysis.

  6. Biogas - the calculable energy

    NASA Astrophysics Data System (ADS)

    Kith, Károly; Nagy, Orsolya; Balla, Zoltán; Tamás, András

    2015-04-01

    EU actions against climate change are rising energy prices, both have emphasized the use of renewable energy,increase investments and energy efficiency. A number of objectives formulated in the EC decree no. 29/2009 by 2020. This document is based on the share of renewable energies in energy consumption should be increased to 20% (EC, 2009). The EU average is 20% but the share of renewables vary from one member state to another. In Hungary in 2020, 14.65% renewable energy share is planned to be achieved. According to the latest Eurostat data, the share of renewable energy in energy consumption of the EU average was 14.1%, while in Hungary, this share was 9.6% in 2012. (EUROSTAT, 2014). The use of renewable energy plant level is influenced by several factors. The most important of these is the cost savings and efficiency gains. Hungarian investments in renewable energy production usually have high associated costs and the payback period is substantially more than five years, depending on the support rate. For example, the payback period is also influenced by the green electricity generated feed prices, which is one of the lowest in Hungary compared the Member States of the European Union. Consequently, it is important to increase the production of green energy. Nowadays, predictable biogas energy is an outstanding type of decentralized energy production. It follows directly that agricultural by-products can be used to produce energy and they also create jobs by the construction of a biogas plant. It is important to dispose of and destroy hazardous and noxious substances in energy production. It follows from this that the construction of biogas plants have a positive impact, in addition to green energy which is prepared to reduce the load on the environment. The production of biogas and green electricity is one of the most environment friendly forms of energy production. Biogas production also has other important ecological effects, such as the substitution of fertilizers, reducing its use in agriculture, which protects groundwater and surface water conditions and reduces the amount of greenhouse gases in the atmosphere. In the future more emphasis should be given to increase the effectiveness of existing technologies and other types of innovation could be expanded in energy production. It can be concluded that green energy investments can be rewarding if accurate planning is carried out before the investment.

  7. Methods for assessing the energy-saving efficiency of industrial symbiosis in industrial parks.

    PubMed

    Li, Wenfeng; Cui, Zhaojie; Han, Feng

    2015-01-01

    The available energy resources are being depleted worldwide. Industrial symbiosis (IS) provides a promising approach for increasing the efficiency of energy utilization, with numerous studies reporting the superiority of this technology. However, studies quantifying the energy-saving efficiency of IS remain insufficient. This paper proposes an index system for the quantitative evaluation of the energy-saving efficiency of IS. Both energy-saving and financial indexes were selected, the former include the IS energy-saving index, the contribution rate of energy saved through IS, fractional energy savings, and cut rate of energy consumption per total output value; and the latter include the IS investment payback period, IS input-output ratio, net present value (NPV), and internal rate of return (IRR) of IS. The proposed methods were applied to a case study on the XF Industrial Park (XF IP), in the city of Liaocheng in Shandong Province of China. Three energy-saving channels using IS were found in the XF IP: (a) utilizing the energy of high-temperature materials among industrial processes, (b) recovering waste heat and steam between different processes, and (c) saving energy by sharing infrastructures. The results showed that the energy efficiency index of IS was 0.326, accounting for 34.6% of the comprehensive energy-saving index in 2011, and the fractional energy-savings were 12.42%. The index of energy consumption per total industrial output value varied from 90.9 tce/MRMB to 51.6 tce/MRMB. Thus, the cut rate of energy consumption per total industrial output value was 43.42%. The average values of the IS input-output ratio was 406.2 RMB/tce, 57.2% lower than the price of standard coal. Static investment payback period in the XF IP was 8.5 months, indicating that the XF IP began to earn profit 8.5 months after the construction of all IS modes. The NVP and IRR of each IS mode in the XF IP were greater than zero, with average values equal to 1,789.96 MRMB and 140.96%, respectively. The computation result for each indicator revealed that IS could lead to the use of energy with high efficiency and lighten the financial burden of enterprises in the XF IP. And the proposed index system may help IPs and EIPs to make strategic decisions when designing IS modes.

  8. Two-way ANOVA Problems with Simple Numbers.

    ERIC Educational Resources Information Center

    Read, K. L. Q.; Shihab, L. H.

    1998-01-01

    Describes how to construct simple numerical examples in two-way ANOVAs, specifically randomized blocks, balanced two-way layouts, and Latin squares. Indicates that working through simple numerical problems is helpful to students meeting a technique for the first time and should be followed by computer-based analysis of larger, real datasets when…

  9. Social Network Analysis: A Simple but Powerful Tool for Identifying Teacher Leaders

    ERIC Educational Resources Information Center

    Smith, P. Sean; Trygstad, Peggy J.; Hayes, Meredith L.

    2018-01-01

    Instructional teacher leadership is central to a vision of distributed leadership. However, identifying instructional teacher leaders can be a daunting task, particularly for administrators who find themselves either newly appointed or faced with high staff turnover. This article describes the use of social network analysis (SNA), a simple but…

  10. Mantle convection and the state of the Earth's interior

    NASA Technical Reports Server (NTRS)

    Hager, Bradford H.

    1987-01-01

    During 1983 to 1986 emphasis in the study of mantle convection shifted away from fluid mechanical analysis of simple systems with uniform material properties and simple geometries, toward analysis of the effects of more complicated, presumably more realistic models. The important processes related to mantle convection are considered. The developments in seismology are discussed.

  11. Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birru, Dagnachew; Wen, Yao-Jung; Rubinstein, Francis M.

    2013-10-28

    This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach tomore » determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.« less

  12. Economic assessment and energy model scenarios of municipal solid waste incineration and gas turbine hybrid dual-fueled cycles in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Udomsri, Seksan, E-mail: seksan.udomsri@energy.kth.s; Martin, Andrew R.; Fransson, Torsten H.

    Finding environmentally benign methods related to sound municipal solid waste (MSW) management is of highest priority in Southeast Asia. It is very important to study new approaches which can reduce waste generation and simultaneously enhance energy recovery. One concrete example of particular significance is the concept of hybrid dual-fuel power plants featuring MSW and another high-quality fuel like natural gas. The hybrid dual-fuel cycles provide significantly higher electrical efficiencies than a composite of separate single-fuel power plant (standalone gas turbine combined cycle and MSW incineration). Although hybrid versions are of great importance for energy conversion from MSW, an economic assessmentmore » of these systems must be addressed for a realistic appraisal of these technologies. This paper aims to further examine an economic assessment and energy model analysis of different conversion technologies. Energy models are developed to further refine the expected potential of MSW incineration with regards to energy recovery and environmental issues. Results show that MSW incineration can play role for greenhouse gas reduction, energy recovery and waste management. In Bangkok, the electric power production via conventional incineration and hybrid power plants can cover 2.5% and 8% of total electricity consumption, respectively. The hybrid power plants have a relative short payback period (5 years) and can further reduce the CO{sub 2} levels by 3% in comparison with current thermal power plants.« less

  13. Learning-Based Research: The Re-Integration of Learning Styles into STEM Research Through the Context of Solar Energy and Climate Literacy

    NASA Astrophysics Data System (ADS)

    Bosman, L.

    2014-12-01

    This presentation will provide an overview of a NASA NICE-T funded research project at the College of Menominee Nation, a small federally recognized Tribal College located in northern Wisconsin. One main objective of the research project is to provide an experiential learning opportunity for 4-6 STEM students to construct a user friendly solar energy system evaluation tool, incorporating the real-world performance of different solar modules at Argonne National Laboratory, NASA weather and solar irradiation data, and detailed cost analysis and investment payback period. A natural connection exists between Native Americans and renewable energy. The generally clean character of renewable energies provides a great synergy and complimentary attribute for Native Americans' respect and pride for the environment and the overarching concern for future generations (Council, Pierce et al. 2000). Furthermore, Native American cultures have a strong creative and artistic focus, often motivated by their respect and appreciation for nature. The purpose of this learning-based research is to apply a cross-disciplinary approach to integrate the humanities with STEM research within the context of solar energy and climate literacy. Using 7 different learning styles (visual, aural, verbal, physical, logical, social, and solitary), students have the opportunity to showcase their research efforts through a variety of modes and artifacts including graphic novel development (Visual), spoken word poetry (Aural), conference presentation (Verbal), experiential display and demonstration (Physical), debate (Logical), social media and viral messaging (Social), and article submission (Solitary).

  14. Potential fresh water saving using greywater in toilet flushing in Syria.

    PubMed

    Mourad, Khaldoon A; Berndtsson, Justyna C; Berndtsson, Ronny

    2011-10-01

    Greywater reuse is becoming an increasingly important factor for potable water saving in many countries. Syria is one of the most water scarce countries in the Middle East. However, greywater reuse is still not common in the country. Regulations and standards for greywater reuse are not available. Recently, however, several stakeholders have started to plan for greywater reuse. The main objective of this paper is to evaluate the potential for potable water saving by using greywater for toilet flushing in a typical Syrian city. The Sweida city in the southern part of Syria was chosen for this purpose. Interviews were made in order to reflect the social acceptance, water consumption, and the percentage of different indoor water uses. An artificial wetland (AW) and a commercial bio filter (CBF) were proposed to treat the greywater, and an economic analysis was performed for the treatment system. Results show that using treated greywater for toilet flushing would save about 35% of the drinking water. The economic analyses of the two proposed systems showed that, in the current water tariff, the payback period for AW and CBF in block systems is 7 and 52 years, respectively. However, this period will reduce to 3 and 21 years, respectively, if full water costs are paid by beneficiaries. Hence, introducing artificial wetlands in order to make greywater use efficient appears to be a viable alternative to save potable water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Converting campus waste into renewable energy - a case study for the University of Cincinnati.

    PubMed

    Tu, Qingshi; Zhu, Chao; McAvoy, Drew C

    2015-05-01

    This paper evaluates the implementation of three waste-to-energy projects at the University of Cincinnati: waste cooking oil-to-biodiesel, waste paper-to-fuel pellets and food waste-to-biogas, respectively. The implementation of these waste-to-energy (WTE) projects would lead to the improvement of campus sustainability by minimizing waste management efforts and reducing GHG emissions via the displacement of fossil fuel usage. Technical and economic aspects of their implementation were assessed and the corresponding GHG reduction was estimated. Results showed that on-site implementation of these projects would: (1) divert 3682L (974 gallons) of waste cooking oil to 3712L (982 gallons) of biodiesel; (2) produce 138tonnes of fuel pellets from 133tonnes of waste paper (with the addition of 20.75tonnes of plastics) to replace121tonnes of coal; and (3) produce biogas that would be enough to replace 12,767m(3) natural gas every year from 146tonnes of food waste. The economic analysis determined that the payback periods for the three projects would be 16months for the biodiesel, 155months for the fuel pellet, and 74months for the biogas projects. The reduction of GHG emission from the implementation of the three WTE projects was determined to be 9.37 (biodiesel), 260.49 (fuel pellets), and 11.36 (biogas) tonnes of CO2-eq per year, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Economic assessment and energy model scenarios of municipal solid waste incineration and gas turbine hybrid dual-fueled cycles in Thailand.

    PubMed

    Udomsri, Seksan; Martin, Andrew R; Fransson, Torsten H

    2010-07-01

    Finding environmentally benign methods related to sound municipal solid waste (MSW) management is of highest priority in Southeast Asia. It is very important to study new approaches which can reduce waste generation and simultaneously enhance energy recovery. One concrete example of particular significance is the concept of hybrid dual-fuel power plants featuring MSW and another high-quality fuel like natural gas. The hybrid dual-fuel cycles provide significantly higher electrical efficiencies than a composite of separate single-fuel power plant (standalone gas turbine combined cycle and MSW incineration). Although hybrid versions are of great importance for energy conversion from MSW, an economic assessment of these systems must be addressed for a realistic appraisal of these technologies. This paper aims to further examine an economic assessment and energy model analysis of different conversion technologies. Energy models are developed to further refine the expected potential of MSW incineration with regards to energy recovery and environmental issues. Results show that MSW incineration can play role for greenhouse gas reduction, energy recovery and waste management. In Bangkok, the electric power production via conventional incineration and hybrid power plants can cover 2.5% and 8% of total electricity consumption, respectively. The hybrid power plants have a relative short payback period (5 years) and can further reduce the CO(2) levels by 3% in comparison with current thermal power plants. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  17. Simple Rules, Not So Simple: The Use of International Ovarian Tumor Analysis (IOTA) Terminology and Simple Rules in Inexperienced Hands in a Prospective Multicenter Cohort Study.

    PubMed

    Meys, Evelyne; Rutten, Iris; Kruitwagen, Roy; Slangen, Brigitte; Lambrechts, Sandrina; Mertens, Helen; Nolting, Ernst; Boskamp, Dieuwke; Van Gorp, Toon

    2017-12-01

     To analyze how well untrained examiners - without experience in the use of International Ovarian Tumor Analysis (IOTA) terminology or simple ultrasound-based rules (simple rules) - are able to apply IOTA terminology and simple rules and to assess the level of agreement between non-experts and an expert.  This prospective multicenter cohort study enrolled women with ovarian masses. Ultrasound was performed by non-expert examiners and an expert. Ultrasound features were recorded using IOTA nomenclature, and used for classifying the mass by simple rules. Interobserver agreement was evaluated with Fleiss' kappa and percentage agreement between observers.  50 consecutive women were included. We observed 46 discrepancies in the description of ovarian masses when non-experts utilized IOTA terminology. Tumor type was misclassified often (n = 22), resulting in poor interobserver agreement between the non-experts and the expert (kappa = 0.39, 95 %-CI 0.244 - 0.529, percentage of agreement = 52.0 %). Misinterpretation of simple rules by non-experts was observed 57 times, resulting in an erroneous diagnosis in 15 patients (30 %). The agreement for classifying the mass as benign, malignant or inconclusive by simple rules was only moderate between the non-experts and the expert (kappa = 0.50, 95 %-CI 0.300 - 0.704, percentage of agreement = 70.0 %). The level of agreement for all 10 simple rules features varied greatly (kappa index range: -0.08 - 0.74, percentage of agreement 66 - 94 %).  Although simple rules are useful to distinguish benign from malignant adnexal masses, they are not that simple for untrained examiners. Training with both IOTA terminology and simple rules is necessary before simple rules can be introduced into guidelines and daily clinical practice. © Georg Thieme Verlag KG Stuttgart · New York.

  18. THE MATHEMATICAL ANALYSIS OF A SIMPLE DUEL

    DTIC Science & Technology

    The principles and techniques of simple Markov processes are used to analyze a simple duel to determine the limiting state probabilities (i.e., the...probabilities of occurrence of the various possible outcomes of the duel ). The duel is one in which A fires at B at a rate of r sub A shots per minute

  19. Isolating the Effects of Training Using Simple Regression Analysis: An Example of the Procedure.

    ERIC Educational Resources Information Center

    Waugh, C. Keith

    This paper provides a case example of simple regression analysis, a forecasting procedure used to isolate the effects of training from an identified extraneous variable. This case example focuses on results of a three-day sales training program to improve bank loan officers' knowledge, skill-level, and attitude regarding solicitation and sale of…

  20. Global Study of the Simple Pendulum by the Homotopy Analysis Method

    ERIC Educational Resources Information Center

    Bel, A.; Reartes, W.; Torresi, A.

    2012-01-01

    Techniques are developed to find all periodic solutions in the simple pendulum by means of the homotopy analysis method (HAM). This involves the solution of the equations of motion in two different coordinate representations. Expressions are obtained for the cycles and periods of oscillations with a high degree of accuracy in the whole range of…

  1. Levelized Cost of Energy Calculator | Energy Analysis | NREL

    Science.gov Websites

    Levelized Cost of Energy Calculator Levelized Cost of Energy Calculator Transparent Cost Database Button The levelized cost of energy (LCOE) calculator provides a simple calculator for both utility-scale need to be included for a thorough analysis. To estimate simple cost of energy, use the slider controls

  2. Using High Speed Smartphone Cameras and Video Analysis Techniques to Teach Mechanical Wave Physics

    ERIC Educational Resources Information Center

    Bonato, Jacopo; Gratton, Luigi M.; Onorato, Pasquale; Oss, Stefano

    2017-01-01

    We propose the use of smartphone-based slow-motion video analysis techniques as a valuable tool for investigating physics concepts ruling mechanical wave propagation. The simple experimental activities presented here, suitable for both high school and undergraduate students, allows one to measure, in a simple yet rigorous way, the speed of pulses…

  3. A Simple Card Trick: Teaching Qualitative Data Analysis Using a Deck of Playing Cards

    ERIC Educational Resources Information Center

    Waite, Duncan

    2011-01-01

    Yet today, despite recent welcome additions, relatively little is written about teaching qualitative research. Why is that? This article reports out a relatively simple, yet appealing, pedagogical move, a lesson the author uses to teach qualitative data analysis. Data sorting and categorization, the use of tacit and explicit theory in data…

  4. Monosodium glutamate for simple photometric iron analysis

    NASA Astrophysics Data System (ADS)

    Prasetyo, E.

    2018-01-01

    Simple photometric method for iron analysis using monosodium glutamate (MSG) was proposed. The method could be used as an alternative method, which was technically simple, economic, quantitative, readily available, scientifically sound and environmental friendly. Rapid reaction of iron (III) with glutamate in sodium chloride-hydrochloric acid buffer (pH 2) to form red-brown complex was served as a basis in the photometric determination, which obeyed the range of iron (III) concentration 1.6 - 80 µg/ml. This method could be applied to determine iron concentration in soil with satisfactory results (accuracy and precision) compared to other photometric and atomic absorption spectrometry results.

  5. Modeling shared resources with generalized synchronization within a Petri net bottom-up approach.

    PubMed

    Ferrarini, L; Trioni, M

    1996-01-01

    This paper proposes a simple and effective way to represent shared resources in manufacturing systems within a Petri net model previously developed. Such a model relies on the bottom-up and modular approach to synthesis and analysis. The designer may define elementary tasks and then connect them with one another with three kinds of connections: self-loops, inhibitor arcs and simple synchronizations. A theoretical framework has been established for the analysis of liveness and reversibility of such models. The generalized synchronization, here formalized, represents an extension of the simple synchronization, allowing the merging of suitable subnets among elementary tasks. It is proved that under suitable, but not restrictive, hypotheses the generalized synchronization may be substituted for a simple one, thus being compatible with all the developed theoretical body.

  6. Development of methodology for horizontal axis wind turbine dynamic analysis

    NASA Technical Reports Server (NTRS)

    Dugundji, J.

    1982-01-01

    Horizontal axis wind turbine dynamics were studied. The following findings are summarized: (1) review of the MOSTAS computer programs for dynamic analysis of horizontal axis wind turbines; (2) review of various analysis methods for rotating systems with periodic coefficients; (3) review of structural dynamics analysis tools for large wind turbine; (4) experiments for yaw characteristics of a rotating rotor; (5) development of a finite element model for rotors; (6) development of simple models for aeroelastics; and (7) development of simple models for stability and response of wind turbines on flexible towers.

  7. A simple protocol for NMR analysis of the enantiomeric purity of chiral hydroxylamines.

    PubMed

    Tickell, David A; Mahon, Mary F; Bull, Steven D; James, Tony D

    2013-02-15

    A practically simple three-component chiral derivatization protocol for determining the enantiopurity of chiral hydroxylamines by (1)H NMR spectroscopic analysis is described, involving their treatment with 2-formylphenylboronic acid and enantiopure BINOL to afford a mixture of diastereomeric nitrono-boronate esters whose ratio is an accurate reflection of the enantiopurity of the parent hydroxylamine.

  8. Simulating and mapping spatial complexity using multi-scale techniques

    USGS Publications Warehouse

    De Cola, L.

    1994-01-01

    A central problem in spatial analysis is the mapping of data for complex spatial fields using relatively simple data structures, such as those of a conventional GIS. This complexity can be measured using such indices as multi-scale variance, which reflects spatial autocorrelation, and multi-fractal dimension, which characterizes the values of fields. These indices are computed for three spatial processes: Gaussian noise, a simple mathematical function, and data for a random walk. Fractal analysis is then used to produce a vegetation map of the central region of California based on a satellite image. This analysis suggests that real world data lie on a continuum between the simple and the random, and that a major GIS challenge is the scientific representation and understanding of rapidly changing multi-scale fields. -Author

  9. relaxGUI: a new software for fast and simple NMR relaxation data analysis and calculation of ps-ns and μs motion of proteins.

    PubMed

    Bieri, Michael; d'Auvergne, Edward J; Gooley, Paul R

    2011-06-01

    Investigation of protein dynamics on the ps-ns and μs-ms timeframes provides detailed insight into the mechanisms of enzymes and the binding properties of proteins. Nuclear magnetic resonance (NMR) is an excellent tool for studying protein dynamics at atomic resolution. Analysis of relaxation data using model-free analysis can be a tedious and time consuming process, which requires good knowledge of scripting procedures. The software relaxGUI was developed for fast and simple model-free analysis and is fully integrated into the software package relax. It is written in Python and uses wxPython to build the graphical user interface (GUI) for maximum performance and multi-platform use. This software allows the analysis of NMR relaxation data with ease and the generation of publication quality graphs as well as color coded images of molecular structures. The interface is designed for simple data analysis and management. The software was tested and validated against the command line version of relax.

  10. Simple arithmetic: not so simple for highly math anxious individuals.

    PubMed

    Chang, Hyesang; Sprute, Lisa; Maloney, Erin A; Beilock, Sian L; Berman, Marc G

    2017-12-01

    Fluency with simple arithmetic, typically achieved in early elementary school, is thought to be one of the building blocks of mathematical competence. Behavioral studies with adults indicate that math anxiety (feelings of tension or apprehension about math) is associated with poor performance on cognitively demanding math problems. However, it remains unclear whether there are fundamental differences in how high and low math anxious individuals approach overlearned simple arithmetic problems that are less reliant on cognitive control. The current study used functional magnetic resonance imaging to examine the neural correlates of simple arithmetic performance across high and low math anxious individuals. We implemented a partial least squares analysis, a data-driven, multivariate analysis method to measure distributed patterns of whole-brain activity associated with performance. Despite overall high simple arithmetic performance across high and low math anxious individuals, performance was differentially dependent on the fronto-parietal attentional network as a function of math anxiety. Specifically, low-compared to high-math anxious individuals perform better when they activate this network less-a potential indication of more automatic problem-solving. These findings suggest that low and high math anxious individuals approach even the most fundamental math problems differently. © The Author (2017). Published by Oxford University Press.

  11. Simple arithmetic: not so simple for highly math anxious individuals

    PubMed Central

    Sprute, Lisa; Maloney, Erin A; Beilock, Sian L; Berman, Marc G

    2017-01-01

    Abstract Fluency with simple arithmetic, typically achieved in early elementary school, is thought to be one of the building blocks of mathematical competence. Behavioral studies with adults indicate that math anxiety (feelings of tension or apprehension about math) is associated with poor performance on cognitively demanding math problems. However, it remains unclear whether there are fundamental differences in how high and low math anxious individuals approach overlearned simple arithmetic problems that are less reliant on cognitive control. The current study used functional magnetic resonance imaging to examine the neural correlates of simple arithmetic performance across high and low math anxious individuals. We implemented a partial least squares analysis, a data-driven, multivariate analysis method to measure distributed patterns of whole-brain activity associated with performance. Despite overall high simple arithmetic performance across high and low math anxious individuals, performance was differentially dependent on the fronto-parietal attentional network as a function of math anxiety. Specifically, low—compared to high—math anxious individuals perform better when they activate this network less—a potential indication of more automatic problem-solving. These findings suggest that low and high math anxious individuals approach even the most fundamental math problems differently. PMID:29140499

  12. Simple Benchmark Specifications for Space Radiation Protection

    NASA Technical Reports Server (NTRS)

    Singleterry, Robert C. Jr.; Aghara, Sukesh K.

    2013-01-01

    This report defines space radiation benchmark specifications. This specification starts with simple, monoenergetic, mono-directional particles on slabs and progresses to human models in spacecraft. This report specifies the models and sources needed to what the team performing the benchmark needs to produce in a report. Also included are brief descriptions of how OLTARIS, the NASA Langley website for space radiation analysis, performs its analysis.

  13. Uncertainty analysis on simple mass balance model to calculate critical loads for soil acidity

    Treesearch

    Harbin Li; Steven G. McNulty

    2007-01-01

    Simple mass balance equations (SMBE) of critical acid loads (CAL) in forest soil were developed to assess potential risks of air pollutants to ecosystems. However, to apply SMBE reliably at large scales, SMBE must be tested for adequacy and uncertainty. Our goal was to provide a detailed analysis of uncertainty in SMBE so that sound strategies for scaling up CAL...

  14. Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials.

    PubMed

    Potas, Jason Robert; de Castro, Newton Gonçalves; Maddess, Ted; de Souza, Marcio Nogueira

    2015-01-01

    Experimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and derive their latencies and magnitudes using a simple cross-correlation template comparison approach. For this, we developed an algorithm called Waveform Similarity Analysis. To test the algorithm, challenging signals were generated in vivo by stimulating sural and sciatic nerves, whilst recording evoked potentials at the sciatic nerve and tibialis anterior muscle, respectively, in animals recovering from sciatic nerve transection. Our template for the algorithm was generated based on responses evoked from the intact side. We also simulated noisy signals and examined the output of the Waveform Similarity Analysis algorithm with imperfect templates. Signals were detected and quantified using Waveform Similarity Analysis, which was compared to event detection, latency and magnitude measurements of the same signals performed by a trained observer, a process we called Trained Eye Analysis. The Waveform Similarity Analysis algorithm could successfully detect and quantify simple or complex responses from nerve and muscle compound action potentials of intact or regenerated nerves. Incorrectly specifying the template outperformed Trained Eye Analysis for predicting signal amplitude, but produced consistent latency errors for the simulated signals examined. Compared to the trained eye, Waveform Similarity Analysis is automatic, objective, does not rely on the observer to identify and/or measure peaks, and can detect small clustered events even when signal-to-noise ratio is poor. Waveform Similarity Analysis provides a simple, reliable and convenient approach to quantify latencies and magnitudes of complex waveforms and therefore serves as a useful tool for studying evoked compound action potentials in neural regeneration studies.

  15. Waveform Similarity Analysis: A Simple Template Comparing Approach for Detecting and Quantifying Noisy Evoked Compound Action Potentials

    PubMed Central

    Potas, Jason Robert; de Castro, Newton Gonçalves; Maddess, Ted; de Souza, Marcio Nogueira

    2015-01-01

    Experimental electrophysiological assessment of evoked responses from regenerating nerves is challenging due to the typical complex response of events dispersed over various latencies and poor signal-to-noise ratio. Our objective was to automate the detection of compound action potential events and derive their latencies and magnitudes using a simple cross-correlation template comparison approach. For this, we developed an algorithm called Waveform Similarity Analysis. To test the algorithm, challenging signals were generated in vivo by stimulating sural and sciatic nerves, whilst recording evoked potentials at the sciatic nerve and tibialis anterior muscle, respectively, in animals recovering from sciatic nerve transection. Our template for the algorithm was generated based on responses evoked from the intact side. We also simulated noisy signals and examined the output of the Waveform Similarity Analysis algorithm with imperfect templates. Signals were detected and quantified using Waveform Similarity Analysis, which was compared to event detection, latency and magnitude measurements of the same signals performed by a trained observer, a process we called Trained Eye Analysis. The Waveform Similarity Analysis algorithm could successfully detect and quantify simple or complex responses from nerve and muscle compound action potentials of intact or regenerated nerves. Incorrectly specifying the template outperformed Trained Eye Analysis for predicting signal amplitude, but produced consistent latency errors for the simulated signals examined. Compared to the trained eye, Waveform Similarity Analysis is automatic, objective, does not rely on the observer to identify and/or measure peaks, and can detect small clustered events even when signal-to-noise ratio is poor. Waveform Similarity Analysis provides a simple, reliable and convenient approach to quantify latencies and magnitudes of complex waveforms and therefore serves as a useful tool for studying evoked compound action potentials in neural regeneration studies. PMID:26325291

  16. Item Selection, Evaluation, and Simple Structure in Personality Data

    PubMed Central

    Pettersson, Erik; Turkheimer, Eric

    2010-01-01

    We report an investigation of the genesis and interpretation of simple structure in personality data using two very different self-reported data sets. The first consists of a set of relatively unselected lexical descriptors, whereas the second is based on responses to a carefully constructed instrument. In both data sets, we explore the degree of simple structure by comparing factor solutions to solutions from simulated data constructed to have either strong or weak simple structure. The analysis demonstrates that there is little evidence of simple structure in the unselected items, and a moderate degree among the selected items. In both instruments, however, much of the simple structure that could be observed originated in a strong dimension of positive vs. negative evaluation. PMID:20694168

  17. An Assessment of the Technical Readiness of the Vapor Phase Catalytic Ammonia Removal Process (VPCAR) Technology

    NASA Technical Reports Server (NTRS)

    Flynn, Michael

    2000-01-01

    This poster provides an assessment of the technical readiness of the Vapor Phase Catalytic Ammonia Removal Process (VPCAR). The VPCAR technology is a fully regenerative water recycling technology designed specifically for applications such as a near term Mars exploration mission. The VPCAR technology is a highly integrated distillation/catalytic oxidation based water processor. It is designed to accept a combined wastewater stream (urine, condensate, and hygiene) and produces potable water in a single process step which requires -no regularly scheduled re-supply or maintenance for a 3 year mission. The technology is designed to be modular and to fit into a volume comparable to a single International Space Station Rack (when sized for a crew of 6). This poster provides a description of the VPCAR technology and a summary of the current performance of the technology. Also provided are the results of two separate NASA sponsored system trade studies which investigated the potential payback of further development of the VPCAR technology.

  18. Wind power as an electrical energy source in Illinois

    NASA Astrophysics Data System (ADS)

    Wendland, W. M.

    1982-03-01

    A preliminary estimate of the total wind power available in Illinois was made using available historical data, and projections of cost savings due to the presence of wind-generated electricity were attempted. Wind data at 10 m height were considered from nine different sites in the state, with three years data nominally being included. Wind-speed frequency histograms were developed for day and night periods, using a power law function to extrapolate the 10 m readings to 20 m. Wind speeds over the whole state were found to average over 8 mph, the cut-in point for most wind turbines, for from 40-63% of the time. A maximum of 75% run-time was determined for daylight hours in April-May. A reference 1.8 kW windpowered generator was used in annual demand projections for a reference one family home, using the frequency histograms. The small generator was projected to fulfill from 25-53% of the annual load, and, based on various cost assumptions, exhibited paybacks taking from 14-27 yr.

  19. Ultrafast decoherence dynamics govern photocarrier generation efficiencies in polymer solar cells

    PubMed Central

    Vella, Eleonora; Li, Hao; Grégoire, Pascal; Tuladhar, Sachetan M.; Vezie, Michelle S.; Few, Sheridan; Bazán, Claudia M.; Nelson, Jenny; Silva-Acuña, Carlos; Bittner, Eric R.

    2016-01-01

    All-organic-based photovoltaic solar cells have attracted considerable attention because of their low-cost processing and short energy payback time. In such systems the primary dissociation of an optical excitation into a pair of photocarriers has been recently shown to be extremely rapid and efficient, but the physical reason for this remains unclear. Here, two-dimensional photocurrent excitation spectroscopy, a novel non-linear optical spectroscopy, is used to probe the ultrafast coherent decay of photoexcitations into charge-producing states in a polymer:fullerene based solar cell. The two-dimensional photocurrent spectra are interpreted by introducing a theoretical model for the description of the coupling of the electronic states of the system to an external environment and to the applied laser fields. The experimental data show no cross-peaks in the twodimensional photocurrent spectra, as predicted by the model for coherence times between the exciton and the photocurrent producing states of 20 fs or less. PMID:27412119

  20. Energy efficiency opportunities in the brewery industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worrell, Ernst; Galitsky, Christina; Martin, Nathan

    2002-06-28

    Breweries in the United States spend annually over $200 Million on energy. Energy consumption is equal to 3-8% of the production costs of beer, making energy efficiency improvement an important way to reduce costs, especially in times of high energy price volatility. After a summary of the beer making process and energy use, we examine energy efficiency opportunities available for breweries. We provide specific primary energy savings for each energy efficiency measure based on case studies that have implemented the measures, as well as references to technical literature. If available, we have also listed typical payback periods. Our findings suggestmore » that there may still be opportunities to reduce energy consumption cost-effectively for breweries. Major brewing companies have and will continue to spend capital on cost effective measures that do not impact the quality of the beer. Further research on the economics of the measures, as well as their applicability to different brewing practices, is needed to assess implementation of selected technologies at individual breweries.« less

Top