Sample records for simple procedure based

  1. Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.

    ERIC Educational Resources Information Center

    Pike, R. M.; And Others

    1986-01-01

    Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)

  2. The generation of simple compliance boundaries for mobile communication base station antennas using formulae for SAR estimation.

    PubMed

    Thors, B; Hansson, B; Törnevik, C

    2009-07-07

    In this paper, a procedure is proposed for generating simple and practical compliance boundaries for mobile communication base station antennas. The procedure is based on a set of formulae for estimating the specific absorption rate (SAR) in certain directions around a class of common base station antennas. The formulae, given for both whole-body and localized SAR, require as input the frequency, the transmitted power and knowledge of antenna-related parameters such as dimensions, directivity and half-power beamwidths. With knowledge of the SAR in three key directions it is demonstrated how simple and practical compliance boundaries can be generated outside of which the exposure levels do not exceed certain limit values. The conservativeness of the proposed procedure is discussed based on results from numerical radio frequency (RF) exposure simulations with human body phantoms from the recently developed Virtual Family.

  3. Operator priming and generalization of practice in adults' simple arithmetic.

    PubMed

    Chen, Yalin; Campbell, Jamie I D

    2016-04-01

    There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication, suggesting that a general addition procedure was primed by the + sign. In Experiment 1 (n = 36), we applied this operator-priming paradigm to rule-based problems (0 + N = N, 1 × N = N, 0 × N = 0) and 1 + N problems with N ranging from 0 to 9. For the rule-based problems, we found both operator-preview facilitation and generalization of practice (e.g., practicing 0 + 3 sped up unpracticed 0 + 8), the latter being a signature of procedure use; however, we also found operator-preview facilitation for 1 + N in the absence of generalization, which implies the 1 + N problems were solved by fact retrieval but nonetheless were facilitated by an operator preview. Thus, the operator preview effect does not discriminate procedure use from fact retrieval. Experiment 2 (n = 36) investigated whether a population with advanced mathematical training-engineering and computer science students-would show generalization of practice for nonrule-based simple addition problems (e.g., 1 + 4, 4 + 7). The 0 + N problems again presented generalization, whereas no nonzero problem type did; but all nonzero problems sped up when the identical problems were retested, as predicted by item-specific fact retrieval. The results pose a strong challenge to the generality of the proposal that skilled adults' simple addition is based on fast procedural algorithms, and instead support a fact-retrieval model of fast addition performance. (c) 2016 APA, all rights reserved).

  4. Promoting North-South partnership in space data use and applications: Case study - East African countries space programs/projects new- concepts in document management

    NASA Astrophysics Data System (ADS)

    Mlimandago, S.

    This research paper have gone out with very simple and easy (several) new concepts in document management for space projects and programs which can be applied anywhere both in the developing and developed countries. These several new concepts are and have been applied in Tanzania, Kenya and Uganda and found out to bear very good results using simple procedures. The intergral project based its documentation management approach from the outset on electronic document sharing and archiving. The main objective of having new concepts was to provide a faster and wider availability of the most current space information to all parties rather than creating a paperless office. Implementation of the new concepts approach required the capturing of documents in an appropriate and simple electronic format at source establishing new procedures for project wide information sharing and the deployment of a new generation of simple procedure - WEB - based tools. Key success factors were the early adoption of Internet technologies and simple procedures for improved information flow new concepts which can be applied anywhere both in the developed and the developing countries.

  5. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    NASA Astrophysics Data System (ADS)

    Li, Er Qiang; Zhang, Jia Ming; Thoroddsen, Sigurdur T.

    2014-01-01

    Droplet-based microfluidic devices have become a preferred versatile platform for various fields in physics, chemistry and biology. Polydimethylsiloxane soft lithography, the mainstay for fabricating microfluidic devices, usually requires the usage of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions. The advantages of our method lie in a simple manufacturing procedure, inexpensive processing equipment and flexibility in the surface modification of the designed microfluidic devices. Different types of devices have been designed and tested and the experimental results demonstrated their robustness for preparing monodisperse single, double, triple and multi-component emulsions.

  6. Operator Priming and Generalization of Practice in Adults' Simple Arithmetic

    ERIC Educational Resources Information Center

    Chen, Yalin; Campbell, Jamie I. D.

    2016-01-01

    There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication,…

  7. Additivity of nonlinear biomass equations

    Treesearch

    Bernard R. Parresol

    2001-01-01

    Two procedures that guarantee the property of additivity among the components of tree biomass and total tree biomass utilizing nonlinear functions are developed. Procedure 1 is a simple combination approach, and procedure 2 is based on nonlinear joint-generalized regression (nonlinear seemingly unrelated regressions) with parameter restrictions. Statistical theory is...

  8. An analysis of ratings: A guide to RMRATE

    Treesearch

    Thomas C. Brown; Terry C. Daniel; Herbert W. Schroeder; Glen E. Brink

    1990-01-01

    This report describes RMRATE, a computer program for analyzing rating judgments. RMRATE scales ratings using several scaling procedures, and compares the resulting scale values. The scaling procedures include the median and simple mean, standardized values, scale values based on Thurstone's Law of Categorical Judgment, and regression-based values. RMRATE also...

  9. Optimal spatial sampling techniques for ground truth data in microwave remote sensing of soil moisture

    NASA Technical Reports Server (NTRS)

    Rao, R. G. S.; Ulaby, F. T.

    1977-01-01

    The paper examines optimal sampling techniques for obtaining accurate spatial averages of soil moisture, at various depths and for cell sizes in the range 2.5-40 acres, with a minimum number of samples. Both simple random sampling and stratified sampling procedures are used to reach a set of recommended sample sizes for each depth and for each cell size. Major conclusions from statistical sampling test results are that (1) the number of samples required decreases with increasing depth; (2) when the total number of samples cannot be prespecified or the moisture in only one single layer is of interest, then a simple random sample procedure should be used which is based on the observed mean and SD for data from a single field; (3) when the total number of samples can be prespecified and the objective is to measure the soil moisture profile with depth, then stratified random sampling based on optimal allocation should be used; and (4) decreasing the sensor resolution cell size leads to fairly large decreases in samples sizes with stratified sampling procedures, whereas only a moderate decrease is obtained in simple random sampling procedures.

  10. A simple spectrophotometric method for determination of zirconium or hafnium in selected molybdenum-base alloys

    NASA Technical Reports Server (NTRS)

    Dupraw, W. A.

    1972-01-01

    A simple analytical procedure is described for accurately and precisely determining the zirconium or hafnium content of molybdenum-base alloys. The procedure is based on the reaction of the reagent Arsenazo III with zirconium or hafnium in strong hydrochloric acid solution. The colored complexes of zirconium or hafnium are formed in the presence of molybdenum. Titanium or rhenium in the alloy have no adverse effect on the zirconium or hafnium complex at the following levels in the selected aliquot: Mo, 10 mg; Re, 10 mg; Ti, 1 mg. The spectrophotometric measurement of the zirconium or hafnium complex is accomplished without prior separation with a relative standard deviation of 1.3 to 2.7 percent.

  11. Clinical and Benefit-Cost Outcomes of Teaching a Mindfulness-Based Procedure to Adult Offenders with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Singh, Nirbhay N.; Lancioni, Giulio E.; Winton, Alan S. W.; Singh, Ashvind N.; Adkins, Angela D.; Singh, Judy

    2008-01-01

    The effects of a mindfulness-based procedure, called "Meditation on the Soles of the Feet", were evaluated as a cognitive-behavioral intervention for physical aggression in 6 offenders with mild intellectual disabilities. They were taught a simple meditation technique that required them to shift their attention and awareness from the precursors of…

  12. Segmentation by fusion of histogram-based k-means clusters in different color spaces.

    PubMed

    Mignotte, Max

    2008-05-01

    This paper presents a new, simple, and efficient segmentation approach, based on a fusion procedure which aims at combining several segmentation maps associated to simpler partition models in order to finally get a more reliable and accurate segmentation result. The different label fields to be fused in our application are given by the same and simple (K-means based) clustering technique on an input image expressed in different color spaces. Our fusion strategy aims at combining these segmentation maps with a final clustering procedure using as input features, the local histogram of the class labels, previously estimated and associated to each site and for all these initial partitions. This fusion framework remains simple to implement, fast, general enough to be applied to various computer vision applications (e.g., motion detection and segmentation), and has been successfully applied on the Berkeley image database. The experiments herein reported in this paper illustrate the potential of this approach compared to the state-of-the-art segmentation methods recently proposed in the literature.

  13. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    PubMed

    Sparding, Nadja; Slotved, Hans-Christian; Nicolaisen, Gert M; Giese, Steen B; Elmlund, Jón; Steenhard, Nina R

    2014-01-01

    After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin) with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments) for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  14. Manga Vectorization and Manipulation with Procedural Simple Screentone.

    PubMed

    Yao, Chih-Yuan; Hung, Shih-Hsuan; Li, Guo-Wei; Chen, I-Yu; Adhitya, Reza; Lai, Yu-Chi

    2017-02-01

    Manga are a popular artistic form around the world, and artists use simple line drawing and screentone to create all kinds of interesting productions. Vectorization is helpful to digitally reproduce these elements for proper content and intention delivery on electronic devices. Therefore, this study aims at transforming scanned Manga to a vector representation for interactive manipulation and real-time rendering with arbitrary resolution. Our system first decomposes the patch into rough Manga elements including possible borders and shading regions using adaptive binarization and screentone detector. We classify detected screentone into simple and complex patterns: our system extracts simple screentone properties for refining screentone borders, estimating lighting, compensating missing strokes inside screentone regions, and later resolution independently rendering with our procedural shaders. Our system treats the others as complex screentone areas and vectorizes them with our proposed line tracer which aims at locating boundaries of all shading regions and polishing all shading borders with the curve-based Gaussian refiner. A user can lay down simple scribbles to cluster Manga elements intuitively for the formation of semantic components, and our system vectorizes these components into shading meshes along with embedded Bézier curves as a unified foundation for consistent manipulation including pattern manipulation, deformation, and lighting addition. Our system can real-time and resolution independently render the shading regions with our procedural shaders and drawing borders with the curve-based shader. For Manga manipulation, the proposed vector representation can be not only magnified without artifacts but also deformed easily to generate interesting results.

  15. Benchmarking gate-based quantum computers

    NASA Astrophysics Data System (ADS)

    Michielsen, Kristel; Nocon, Madita; Willsch, Dennis; Jin, Fengping; Lippert, Thomas; De Raedt, Hans

    2017-11-01

    With the advent of public access to small gate-based quantum processors, it becomes necessary to develop a benchmarking methodology such that independent researchers can validate the operation of these processors. We explore the usefulness of a number of simple quantum circuits as benchmarks for gate-based quantum computing devices and show that circuits performing identity operations are very simple, scalable and sensitive to gate errors and are therefore very well suited for this task. We illustrate the procedure by presenting benchmark results for the IBM Quantum Experience, a cloud-based platform for gate-based quantum computing.

  16. Non-Procedural Languages for Information Resource Management.

    ERIC Educational Resources Information Center

    Bearley, William L.

    The future of information resources management requires new approaches to implementing systems which will include a type of data base management that frees users to solve data processing problems logically by telling the system what they want, together with powerful non-procedural languages that will permit communication in simple, concise…

  17. Using Statistical Process Control to Make Data-Based Clinical Decisions.

    ERIC Educational Resources Information Center

    Pfadt, Al; Wheeler, Donald J.

    1995-01-01

    Statistical process control (SPC), which employs simple statistical tools and problem-solving techniques such as histograms, control charts, flow charts, and Pareto charts to implement continual product improvement procedures, can be incorporated into human service organizations. Examples illustrate use of SPC procedures to analyze behavioral data…

  18. A Simple Acronym for Doing Calculus: CAL

    ERIC Educational Resources Information Center

    Hathaway, Richard J.

    2008-01-01

    An acronym is presented that provides students a potentially useful, unifying view of the major topics covered in an elementary calculus sequence. The acronym (CAL) is based on viewing the calculus procedure for solving a calculus problem P* in three steps: (1) recognizing that the problem cannot be solved using simple (non-calculus) techniques;…

  19. The Feasibility of Real-Time Intraoperative Performance Assessment With SIMPL (System for Improving and Measuring Procedural Learning): Early Experience From a Multi-institutional Trial.

    PubMed

    Bohnen, Jordan D; George, Brian C; Williams, Reed G; Schuller, Mary C; DaRosa, Debra A; Torbeck, Laura; Mullen, John T; Meyerson, Shari L; Auyang, Edward D; Chipman, Jeffrey G; Choi, Jennifer N; Choti, Michael A; Endean, Eric D; Foley, Eugene F; Mandell, Samuel P; Meier, Andreas H; Smink, Douglas S; Terhune, Kyla P; Wise, Paul E; Soper, Nathaniel J; Zwischenberger, Joseph B; Lillemoe, Keith D; Dunnington, Gary L; Fryer, Jonathan P

    Intraoperative performance assessment of residents is of growing interest to trainees, faculty, and accreditors. Current approaches to collect such assessments are limited by low participation rates and long delays between procedure and evaluation. We deployed an innovative, smartphone-based tool, SIMPL (System for Improving and Measuring Procedural Learning), to make real-time intraoperative performance assessment feasible for every case in which surgical trainees participate, and hypothesized that SIMPL could be feasibly integrated into surgical training programs. Between September 1, 2015 and February 29, 2016, 15 U.S. general surgery residency programs were enrolled in an institutional review board-approved trial. SIMPL was made available after 70% of faculty and residents completed a 1-hour training session. Descriptive and univariate statistics analyzed multiple dimensions of feasibility, including training rates, volume of assessments, response rates/times, and dictation rates. The 20 most active residents and attendings were evaluated in greater detail. A total of 90% of eligible users (1267/1412) completed training. Further, 13/15 programs began using SIMPL. Totally, 6024 assessments were completed by 254 categorical general surgery residents (n = 3555 assessments) and 259 attendings (n = 2469 assessments), and 3762 unique operations were assessed. There was significant heterogeneity in participation within and between programs. Mean percentage (range) of users who completed ≥1, 5, and 20 assessments were 62% (21%-96%), 34% (5%-75%), and 10% (0%-32%) across all programs, and 96%, 75%, and 32% in the most active program. Overall, response rate was 70%, dictation rate was 24%, and mean response time was 12 hours. Assessments increased from 357 (September 2015) to 1146 (February 2016). The 20 most active residents each received mean 46 assessments by 10 attendings for 20 different procedures. SIMPL can be feasibly integrated into surgical training programs to enhance the frequency and timeliness of intraoperative performance assessment. We believe SIMPL could help facilitate a national competency-based surgical training system, although local and systemic challenges still need to be addressed. Copyright © 2016. Published by Elsevier Inc.

  20. A simple test of association for contingency tables with multiple column responses.

    PubMed

    Decady, Y J; Thomas, D R

    2000-09-01

    Loughin and Scherer (1998, Biometrics 54, 630-637) investigated tests of association in two-way tables when one of the categorical variables allows for multiple-category responses from individual respondents. Standard chi-squared tests are invalid in this case, and they developed a bootstrap test procedure that provides good control of test levels under the null hypothesis. This procedure and some others that have been proposed are computationally involved and are based on techniques that are relatively unfamiliar to many practitioners. In this paper, the methods introduced by Rao and Scott (1981, Journal of the American Statistical Association 76, 221-230) for analyzing complex survey data are used to develop a simple test based on a corrected chi-squared statistic.

  1. New procedure to design low radar cross section near perfect isotropic and homogeneous triangular carpet cloaks.

    PubMed

    Sharifi, Zohreh; Atlasbaf, Zahra

    2016-10-01

    A new design procedure for near perfect triangular carpet cloaks, fabricated based on only isotropic homogeneous materials, is proposed. This procedure enables us to fabricate a cloak with simple metamaterials or even without employing metamaterials. The proposed procedure together with an invasive weed optimization algorithm is used to design carpet cloaks based on quasi-isotropic metamaterial structures, Teflon and AN-73. According to the simulation results, the proposed cloaks have good invisibility properties against radar, especially monostatic radar. The procedure is a new method to derive isotropic and homogeneous parameters from transformation optics formulas so we do not need to use complicated structures to fabricate the carpet cloaks.

  2. Smartphone-aided measurements of the speed of sound in different gaseous mixtures

    NASA Astrophysics Data System (ADS)

    Parolin, Sara Orsola; Pezzi, Giovanni

    2013-11-01

    Here we describe classroom-based procedures aiming at the estimation of the speed of sound in different gas mixtures with the help of a plastic drain pipe and two iPhones or iPod touches. The procedures were conceived to be performed with simple and readily available tools.

  3. Smartphone-Aided Measurements of the Speed of Sound in Different Gaseous Mixtures

    ERIC Educational Resources Information Center

    Parolin, Sara Orsola; Pezzi, Giovanni

    2013-01-01

    Here we describe classroom-based procedures aiming at the estimation of the speed of sound in different gas mixtures with the help of a plastic drain pipe and two iPhones or iPod touches. The procedures were conceived to be performed with simple and readily available tools.

  4. Boundary condition computational procedures for inviscid, supersonic steady flow field calculations

    NASA Technical Reports Server (NTRS)

    Abbett, M. J.

    1971-01-01

    Results are given of a comparative study of numerical procedures for computing solid wall boundary points in supersonic inviscid flow calculatons. Twenty five different calculation procedures were tested on two sample problems: a simple expansion wave and a simple compression (two-dimensional steady flow). A simple calculation procedure was developed. The merits and shortcomings of the various procedures are discussed, along with complications for three-dimensional and time-dependent flows.

  5. Going Beyond, Going Further: The Preparation of Acid-Base Titration Curves.

    ERIC Educational Resources Information Center

    McClendon, Michael

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for a simple technique for generating mechanically plotted acid-base titration curves. The method is suitable for second-year high school chemistry students. (JN)

  6. Jig-Shape Optimization of a Low-Boom Supersonic Aircraft

    NASA Technical Reports Server (NTRS)

    Pak, Chan-gi

    2018-01-01

    A simple approach for optimizing the jig-shape is proposed in this study. This simple approach is based on an unconstrained optimization problem and applied to a low-boom supersonic aircraft. In this study, the jig-shape optimization is performed using the two-step approach. First, starting design variables are computed using the least squares surface fitting technique. Next, the jig-shape is further tuned using a numerical optimization procedure based on in-house object-oriented optimization tool.

  7. Implementation of alanine/EPR as transfer dosimetry system in a radiotherapy audit programme in Belgium.

    PubMed

    Schaeken, B; Cuypers, R; Lelie, S; Schroeyers, W; Schreurs, S; Janssens, H; Verellen, D

    2011-04-01

    A measurement procedure based on alanine/electron paramagnetic resonance (EPR) dosimetry was implemented successfully providing simple, stable, and accurate dose-to-water (D(w)) measurements. The correspondence between alanine and ionization chamber measurements in reference conditions was excellent. Alanine/EMR dosimetry might be a valuable alternative to thermoluminescent (TLD) and ionization chamber based measuring procedures in radiotherapy audits. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. KommonBase - A precise direct bonding system for labial fixed appliances.

    PubMed

    Miyashita, Wataru; Komori, Akira; Takemoto, Kyoto

    2017-09-01

    "KommonBase" is a system designed to customize the bracket base by means of an extended resin base covering the tooth. This system enables precise bracket placement and accurate fit on teeth. Moreover, KommonBase can be easily fabricated in a laboratory and bonded on each tooth using simple clinical procedures. Straight-wire treatment without wire bending was achieved in the clinical cases presented in this article using the KommonBase system for a labial fixed appliance. The application of KommonBase to the vestibular side enables efficient orthodontic treatment using simple mechanics. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  9. Selecting Statistical Procedures for Quality Control Planning Based on Risk Management.

    PubMed

    Yago, Martín; Alcover, Silvia

    2016-07-01

    According to the traditional approach to statistical QC planning, the performance of QC procedures is assessed in terms of its probability of rejecting an analytical run that contains critical size errors (PEDC). Recently, the maximum expected increase in the number of unacceptable patient results reported during the presence of an undetected out-of-control error condition [Max E(NUF)], has been proposed as an alternative QC performance measure because it is more related to the current introduction of risk management concepts for QC planning in the clinical laboratory. We used a statistical model to investigate the relationship between PEDC and Max E(NUF) for simple QC procedures widely used in clinical laboratories and to construct charts relating Max E(NUF) with the capability of the analytical process that allow for QC planning based on the risk of harm to a patient due to the report of erroneous results. A QC procedure shows nearly the same Max E(NUF) value when used for controlling analytical processes with the same capability, and there is a close relationship between PEDC and Max E(NUF) for simple QC procedures; therefore, the value of PEDC can be estimated from the value of Max E(NUF) and vice versa. QC procedures selected by their high PEDC value are also characterized by a low value for Max E(NUF). The PEDC value can be used for estimating the probability of patient harm, allowing for the selection of appropriate QC procedures in QC planning based on risk management. © 2016 American Association for Clinical Chemistry.

  10. A Bioanalytical Chemistry Experiment for Undergraduate Students: Biosensors Based on Metal Nanoparticles

    ERIC Educational Resources Information Center

    Niagi, John; Warner, John; Andreesco, Silvana

    2007-01-01

    The study describes the development of new biosensors based on metal nanoparticles because of its high surface area and large binding ability. The adopted procedure is extremely simple and versatile and can be used in various applications of electrochemistry.

  11. Applied behavior analysis: behavior management of children with autism spectrum disorders in dental environments.

    PubMed

    Hernandez, Purnima; Ikkanda, Zachary

    2011-03-01

    There are a limited number of studies addressing behavior management techniques and procedural modifications that dentists can use to treat people with an autism spectrum disorder (ASD). The authors conducted a search of the dental and behavioral analytic literature to identify management techniques that address problem behaviors exhibited by children with ASDs in dental and other health-related environments. Applied behavior analysis (ABA) is a science in which procedures are based on the principles of behavior through systematic experimentation. Clinicians have used ABA procedures successfully to modify socially significant behaviors of people with ASD. Basic behavior management techniques currently used in dentistry may not encourage people with cognitive and behavioral disabilities, such as ASD, to tolerate simple in-office dental procedures consistently. Instead, dental care providers often are required to use advanced behavior management techniques to complete simple in-office procedures such as prophylaxis, sealant placement and obtaining radiographs. ABA procedures can be integrated in the dental environment to manage problem behaviors often exhibited by children with an ASD. The authors found no evidence-based procedural modifications that address the behavioral characteristics and problematic behaviors of children with an ASD in a dental environment. Further research in this area should be conducted. Knowledge and in-depth understanding of behavioral principles is essential when a dentist is concerned with modifying behaviors. Using ABA procedures can help dentists manage problem behaviors effectively and systematically when performing routine dental treatment. Being knowledgeable about each patient's behavioral characteristics and the parents' level of involvement is important in the successful integration of the procedures and reduction of in-office time.

  12. Complexity, Training Paradigm Design, and the Contribution of Memory Subsystems to Grammar Learning

    PubMed Central

    Ettlinger, Marc; Wong, Patrick C. M.

    2016-01-01

    Although there is variability in nonnative grammar learning outcomes, the contributions of training paradigm design and memory subsystems are not well understood. To examine this, we presented learners with an artificial grammar that formed words via simple and complex morphophonological rules. Across three experiments, we manipulated training paradigm design and measured subjects' declarative, procedural, and working memory subsystems. Experiment 1 demonstrated that passive, exposure-based training boosted learning of both simple and complex grammatical rules, relative to no training. Additionally, procedural memory correlated with simple rule learning, whereas declarative memory correlated with complex rule learning. Experiment 2 showed that presenting corrective feedback during the test phase did not improve learning. Experiment 3 revealed that structuring the order of training so that subjects are first exposed to the simple rule and then the complex improved learning. The cumulative findings shed light on the contributions of grammatical complexity, training paradigm design, and domain-general memory subsystems in determining grammar learning success. PMID:27391085

  13. Radon Adsorbed in Activated Charcoal--A Simple and Safe Radiation Source for Teaching Practical Radioactivity in Schools and Colleges

    ERIC Educational Resources Information Center

    Al-Azmi, Darwish; Mustapha, Amidu O.; Karunakara, N.

    2012-01-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, a ubiquitous inert gas, and the adsorptive property of activated charcoal.…

  14. Simple, Fast, and Sensitive Method for Quantification of Tellurite in Culture Media▿

    PubMed Central

    Molina, Roberto C.; Burra, Radhika; Pérez-Donoso, José M.; Elías, Alex O.; Muñoz, Claudia; Montes, Rebecca A.; Chasteen, Thomas G.; Vásquez, Claudio C.

    2010-01-01

    A fast, simple, and reliable chemical method for tellurite quantification is described. The procedure is based on the NaBH4-mediated reduction of TeO32− followed by the spectrophotometric determination of elemental tellurium in solution. The method is highly reproducible, is stable at different pH values, and exhibits linearity over a broad range of tellurite concentrations. PMID:20525868

  15. Geometric correction of satellite data using curvilinear features and virtual control points

    NASA Technical Reports Server (NTRS)

    Algazi, V. R.; Ford, G. E.; Meyer, D. I.

    1979-01-01

    A simple, yet effective procedure for the geometric correction of partial Landsat scenes is described. The procedure is based on the acquisition of actual and virtual control points from the line printer output of enhanced curvilinear features. The accuracy of this method compares favorably with that of the conventional approach in which an interactive image display system is employed.

  16. A Simple Classroom Simulation of Heat Energy Diffusing through a Metal Bar

    ERIC Educational Resources Information Center

    Kinsler, Mark; Kinzel, Evelyn

    2007-01-01

    We present an iterative procedure that does not rely on calculus to model heat flow through a uniform bar of metal and thus avoids the use of the partial differential equation typically needed to describe heat diffusion. The procedure is based on first principles and can be done with students at the blackboard. It results in a plot that…

  17. Arthroscopic Medial Meniscus Posterior Root Fixation Using a Modified Mason-Allen Stitch.

    PubMed

    Chung, Kyu Sung; Ha, Jeong Ku; Ra, Ho Jong; Kim, Jin Goo

    2016-02-01

    A complete radial tear of the meniscus posterior root, which can effectively cause a state of total meniscectomy via loss of hoop tension, requires that the torn root be repaired. Several methods have been used to repair medial meniscus posterior root tears, most of which are based on a simple stitch technique that is known to have stitch-holding strength. We applied a modified version of the Mason-Allen stitch technique, which is recognized as a method for rotator cuff repair surgery because its locking effect overcomes the potential weakness of simple stitches. This article introduces the medial meniscus posterior root tears repair procedure based on a modified Mason-Allen stitch technique in which 2 strands (i.e., 1 simple horizontal and 1 simple vertical stitch) are used.

  18. Improvement of a sample preparation procedure for multi-elemental determination in Brazil nuts by ICP-OES.

    PubMed

    Welna, Maja; Szymczycha-Madeja, Anna

    2014-04-01

    Various sample preparation procedures, such as common wet digestions and alternatives based on solubilisation in aqua regia or tetramethyl ammonium hydroxide, were compared for the determination of the total Ba, Ca, Cr, Cd, Cu, Fe, Mg, Mn, Ni, P, Pb, Se, Sr and Zn contents in Brazil nuts using inductively coupled plasma optical emission spectrometry (ICP-OES). For measurement of Se, a hydride generation technique was used. The performance of these procedures was measured in terms of precision, accuracy and limits of detection of the elements. It was found that solubilisation in aqua regia gave the best results, i.e. limits of detection from 0.60 to 41.9 ng ml(-1), precision of 1.0-3.9% and accuracy better than 5%. External calibration with simple standard solutions could be applied for the analysis. The proposed procedure is simple, reduces sample handling, and minimises the time and reagent consumption. Thus, this can be a vital alternative to traditional sample treatment approaches based on the total digestion with concentrated reagents. A phenomenon resulting from levels of Ba, Se and Sr in Brazil nuts was also discussed.

  19. Approximate solution of the multiple watchman routes problem with restricted visibility range.

    PubMed

    Faigl, Jan

    2010-10-01

    In this paper, a new self-organizing map (SOM) based adaptation procedure is proposed to address the multiple watchman route problem with the restricted visibility range in the polygonal domain W. A watchman route is represented by a ring of connected neuron weights that evolves in W, while obstacles are considered by approximation of the shortest path. The adaptation procedure considers a coverage of W by the ring in order to attract nodes toward uncovered parts of W. The proposed procedure is experimentally verified in a set of environments and several visibility ranges. Performance of the procedure is compared with the decoupled approach based on solutions of the art gallery problem and the consecutive traveling salesman problem. The experimental results show the suitability of the proposed procedure based on relatively simple supporting geometrical structures, enabling application of the SOM principles to watchman route problems in W.

  20. Performance tests and quality control of cathode ray tube displays.

    PubMed

    Roehrig, H; Blume, H; Ji, T L; Browne, M

    1990-08-01

    Spatial resolution, noise, characteristic curve, and absolute luminance are the essential parameters that describe physical image quality of a display. This paper presents simple procedures for assessing the performance of a cathode ray tube (CRT) in terms of these parameters as well as easy set up techniques. The procedures can be used in the environment where the CRT is used. The procedures are based on a digital representation of the Society of Motion Pictures and Television Engineers pattern plus a few simple other digital patterns. Additionally, measurement techniques are discussed for estimating brightness uniformity, veiling glare, and distortion. Apart from the absolute luminance, all performance features can be assessed with an uncalibrated photodetector and the eyes of a human observer. The measurement techniques especially enable the user to perform comparisons of different display systems.

  1. A design procedure for the phase-controlled parallel-loaded resonant inverter

    NASA Technical Reports Server (NTRS)

    King, Roger J.

    1989-01-01

    High-frequency-link power conversion and distribution based on a resonant inverter (RI) has been recently proposed. The design of several topologies is reviewed, and a simple approximate design procedure is developed for the phase-controlled parallel-loaded RI. This design procedure seeks to ensure the benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. The load is considered to be a linear impedance (or an ac current sink). The design procedure is verified using a 2.5-kVA 20-kHz RI. Also obtained are predictable worst-case ratings for each component of the resonant tank circuit and the inverter switches. For a given load VA requirement, below-resonance operation is found to result in a significantly lower tank VA requirement. Under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible.

  2. The selection of adhesive systems for resin-based luting agents.

    PubMed

    Carville, Rebecca; Quinn, Frank

    2008-01-01

    The use of resin-based luting agents is ever expanding with the development of adhesive dentistry. A multitude of different adhesive systems are used with resin-based luting agents, and new products are introduced to the market frequently. Traditional adhesives generally required a multiple step bonding procedure prior to cementing with active resin-based luting materials; however, combined agents offer a simple application procedure. Self-etching 'all-in-one' systems claim that there is no need for the use of a separate adhesive process. The following review addresses the advantages and disadvantages of the available adhesive systems used with resin-based luting agents.

  3. A simple and highly repeatable viral plaque assay for enterovirus 71.

    PubMed

    Yin, Yingxian; Xu, Yi; Ou, Zhiying; Su, Ling; Xia, Huimin

    2015-04-01

    The classic plaque assay is a method for counting infectious viral particles, however its complexity limits its use in a variety of virological experiments. To simplify the operation and to improve the repeatability, we employed an improved plaque assay procedure based on Avicel to make the whole experiment easier and optimize the results on a model of Vero cells infection with Enterovirus 71(EV71). Clear plaques visible to the naked eyes can be formed on a 24-well plate or a 96-well plate without immunostaining. Following further improvement, this plaque assay procedure could be applied to other viruses, being both simple and repeatable. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Facilitating Proportional Reasoning through Worked Examples: Two Classroom-Based Experiments

    ERIC Educational Resources Information Center

    Bentley, Brendan; Yates, Gregory C. R.

    2017-01-01

    Within mathematics teaching, ways to help students resolve proportional reasoning problems remains a topical issue. This study sought to investigate how a simple innovative procedure could be introduced to enhance skill acquisition. In two classroom-based experiments, 12-year-old students were asked to solve proportional reasoning mathematics…

  5. A Competency Based Curriculum Guide: Ethanol Spark Ignition Engine Conversion.

    ERIC Educational Resources Information Center

    Blair, Brittain A.

    This guide is a competency-based vocational curriculum designed to provide educators with viable ethanol (100 percent alcohol) engine conversion procedures stated in simple terms and set in a flexible educational environment. The curriculum is designed so that educators can form various combinations of instructional activities and resource…

  6. Continuously Variable Rating: a new, simple and logical procedure to evaluate original scientific publications

    PubMed Central

    Silva, Mauricio Rocha e

    2011-01-01

    OBJECTIVE: Impact Factors (IF) are widely used surrogates to evaluate single articles, in spite of known shortcomings imposed by cite distribution skewness. We quantify this asymmetry and propose a simple computer-based procedure for evaluating individual articles. METHOD: (a) Analysis of symmetry. Journals clustered around nine Impact Factor points were selected from the medical “Subject Categories” in Journal Citation Reports 2010. Citable items published in 2008 were retrieved and ranked by granted citations over the Jan/2008 - Jun/2011 period. Frequency distribution of cites, normalized cumulative cites and absolute cites/decile were determined for each journal cluster. (b) Positive Predictive Value. Three arbitrarily established evaluation classes were generated: LOW (1.3≤IF<2.6); MID: (2.6≤IF<3.9); HIGH: (IF≥3.9). Positive Predictive Value for journal clusters within each class range was estimated. (c) Continuously Variable Rating. An alternative evaluation procedure is proposed to allow the rating of individually published articles in comparison to all articles published in the same journal within the same year of publication. The general guiding lines for the construction of a totally dedicated software program are delineated. RESULTS AND CONCLUSIONS: Skewness followed the Pareto Distribution for (1

  7. A Permutation Approach for Selecting the Penalty Parameter in Penalized Model Selection

    PubMed Central

    Sabourin, Jeremy A; Valdar, William; Nobel, Andrew B

    2015-01-01

    Summary We describe a simple, computationally effcient, permutation-based procedure for selecting the penalty parameter in LASSO penalized regression. The procedure, permutation selection, is intended for applications where variable selection is the primary focus, and can be applied in a variety of structural settings, including that of generalized linear models. We briefly discuss connections between permutation selection and existing theory for the LASSO. In addition, we present a simulation study and an analysis of real biomedical data sets in which permutation selection is compared with selection based on the following: cross-validation (CV), the Bayesian information criterion (BIC), Scaled Sparse Linear Regression, and a selection method based on recently developed testing procedures for the LASSO. PMID:26243050

  8. Triangle based TVD schemes for hyperbolic conservation laws

    NASA Technical Reports Server (NTRS)

    Durlofsky, Louis J.; Osher, Stanley; Engquist, Bjorn

    1990-01-01

    A triangle based total variation diminishing (TVD) scheme for the numerical approximation of hyperbolic conservation laws in two space dimensions is constructed. The novelty of the scheme lies in the nature of the preprocessing of the cell averaged data, which is accomplished via a nearest neighbor linear interpolation followed by a slope limiting procedures. Two such limiting procedures are suggested. The resulting method is considerably more simple than other triangle based non-oscillatory approximations which, like this scheme, approximate the flux up to second order accuracy. Numerical results for linear advection and Burgers' equation are presented.

  9. A study of stiffness, residual strength and fatigue life relationships for composite laminates

    NASA Technical Reports Server (NTRS)

    Ryder, J. T.; Crossman, F. W.

    1983-01-01

    Qualitative and quantitative exploration of the relationship between stiffness, strength, fatigue life, residual strength, and damage of unnotched, graphite/epoxy laminates subjected to tension loading. Clarification of the mechanics of the tension loading is intended to explain previous contradictory observations and hypotheses; to develop a simple procedure to anticipate strength, fatigue life, and stiffness changes; and to provide reasons for the study of more complex cases of compression, notches, and spectrum fatigue loading. Mathematical models are developed based upon analysis of the damage states. Mathematical models were based on laminate analysis, free body type modeling or a strain energy release rate. Enough understanding of the tension loaded case is developed to allow development of a proposed, simple procedure for calculating strain to failure, stiffness, strength, data scatter, and shape of the stress-life curve for unnotched laminates subjected to tension load.

  10. Simulations of multi-contrast x-ray imaging using near-field speckles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zdora, Marie-Christine; Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom and Department of Physics & Astronomy, University College London, London, WC1E 6BT; Thibault, Pierre

    2016-01-28

    X-ray dark-field and phase-contrast imaging using near-field speckles is a novel technique that overcomes limitations inherent in conventional absorption x-ray imaging, i.e. poor contrast for features with similar density. Speckle-based imaging yields a wealth of information with a simple setup tolerant to polychromatic and divergent beams, and simple data acquisition and analysis procedures. Here, we present a simulation software used to model the image formation with the speckle-based technique, and we compare simulated results on a phantom sample with experimental synchrotron data. Thorough simulation of a speckle-based imaging experiment will help for better understanding and optimising the technique itself.

  11. General Procedure for the Easy Calculation of pH in an Introductory Course of General or Analytical Chemistry

    ERIC Educational Resources Information Center

    Cepriá, Gemma; Salvatella, Luis

    2014-01-01

    All pH calculations for simple acid-base systems used in introductory courses on general or analytical chemistry can be carried out by using a general procedure requiring the use of predominance diagrams. In particular, the pH is calculated as the sum of an independent term equaling the average pK[subscript a] values of the acids involved in the…

  12. A tutorial solution to scattering of radiation in a thin atmosphere bounded below by a diffusely reflecting, absorbing surface

    NASA Technical Reports Server (NTRS)

    Buglia, J. J.

    1982-01-01

    A simple tutorial method, based on a photon tracking procedure, is described to determine the spherical albedo for a thin atmosphere overlying a reflecting surface. This procedure is used to provide a physical structure with which to interpret the more detailed but highly mathematical analyses presented. The final equations are shown to be in good numerical agreement with more exact solutions for thin atmospheres.

  13. Surgical motion characterization in simulated needle insertion procedures

    NASA Astrophysics Data System (ADS)

    Holden, Matthew S.; Ungi, Tamas; Sargent, Derek; McGraw, Robert C.; Fichtinger, Gabor

    2012-02-01

    PURPOSE: Evaluation of surgical performance in image-guided needle insertions is of emerging interest, to both promote patient safety and improve the efficiency and effectiveness of training. The purpose of this study was to determine if a Markov model-based algorithm can more accurately segment a needle-based surgical procedure into its five constituent tasks than a simple threshold-based algorithm. METHODS: Simulated needle trajectories were generated with known ground truth segmentation by a synthetic procedural data generator, with random noise added to each degree of freedom of motion. The respective learning algorithms were trained, and then tested on different procedures to determine task segmentation accuracy. In the threshold-based algorithm, a change in tasks was detected when the needle crossed a position/velocity threshold. In the Markov model-based algorithm, task segmentation was performed by identifying the sequence of Markov models most likely to have produced the series of observations. RESULTS: For amplitudes of translational noise greater than 0.01mm, the Markov model-based algorithm was significantly more accurate in task segmentation than the threshold-based algorithm (82.3% vs. 49.9%, p<0.001 for amplitude 10.0mm). For amplitudes less than 0.01mm, the two algorithms produced insignificantly different results. CONCLUSION: Task segmentation of simulated needle insertion procedures was improved by using a Markov model-based algorithm as opposed to a threshold-based algorithm for procedures involving translational noise.

  14. Reconstructive procedures for disturbed functions within the upper airway: pharyngeal breathing/snoring

    PubMed Central

    Verse, Thomas

    2005-01-01

    Breathing disorders which have their origin within the pharynx mainly occur during sleep. These so-called obstructive sleep-related breathing disorders include three different disturbances which have to be distinguished properly: simple snoring, upper airway resistance syndrome (UARS) and obstructive sleep apnea (OSA). Each disturbance requires a different treatment. Simple snoring does not affect the physical health of the snorer himself, but often leads to social problems due to the annoying character of the breathing sounds. Appropriate treatment modalities are oral devices and transcutaneous or ttransmucosal electrical stimulation of the muscles of the floor of the mouth via surface electrodes. As reconstructive surgical procedures adenotomies, tonsillectomies, tonsillotomies, or adenotonsillectomies are successfully used in children. Moreover, in adults radiofrequency treatments of the tonsils, the soft palate and of the base of tongue, as well as uvulopalatopharyngoplasty (UPPP), laser-assisted uvulopalatoplasty (LAUP) and palatal implants are adequate treatments for simple snoring. Adequate therapies for UARS and mild OSA (less than 20 breathing events per hour of sleep) are oral appliances. Nasal continuos positive airway pressure (NCPAP) ventilation is a very successful treatment modality, but shows low compliance in these patients, as daytime symptoms like excessive sleepiness or or impaired cognitive functions are often unincisive in patients with mild OSA. Reconstructive procedures like UPPP, radiofrequency surgery of the tonsils or the base of tongue, hyoid suspension, mandibular osteotomy with genioglossus advancement (MO) are successful treatment options either as isolated procedures or in combination within so-called multi-level surgery concepts. Goldstandard for the treatment of moderate to severe OSA is the nCPAP ventilation. All patients should at least try this treatment modality. Only in the rare cases of nCPAP failure (2%) and in the relatively frequent cases of nCPAP incompliance (30%) reconstructive surgical procedures become necessary as second choice treatments. These are adenectomies, tonsillectomies, tonsillotomies in children and hyoid suspension, MO, multi-level surgery concepts, or maxillomandibular advancement osteotomies in adults. PMID:22073056

  15. SERS-based pesticide detection by using nanofinger sensors

    NASA Astrophysics Data System (ADS)

    Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong

    2015-01-01

    Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.

  16. Straightforward Generation of Pillared, Microporous Graphene Frameworks for Use in Supercapacitors.

    PubMed

    Yuan, Kai; Xu, Yazhou; Uihlein, Johannes; Brunklaus, Gunther; Shi, Lei; Heiderhoff, Ralf; Que, Mingming; Forster, Michael; Chassé, Thomas; Pichler, Thomas; Riedl, Thomas; Chen, Yiwang; Scherf, Ullrich

    2015-11-01

    Microporous, pillared graphene-based frameworks are generated in a simple functionalization/coupling procedure starting from reduced graphene oxide. They are used for the fabrication of high-performance supercapacitor devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Derivation of flood frequency curves in poorly gauged Mediterranean catchments using a simple stochastic hydrological rainfall-runoff model

    NASA Astrophysics Data System (ADS)

    Aronica, G. T.; Candela, A.

    2007-12-01

    SummaryIn this paper a Monte Carlo procedure for deriving frequency distributions of peak flows using a semi-distributed stochastic rainfall-runoff model is presented. The rainfall-runoff model here used is very simple one, with a limited number of parameters and practically does not require any calibration, resulting in a robust tool for those catchments which are partially or poorly gauged. The procedure is based on three modules: a stochastic rainfall generator module, a hydrologic loss module and a flood routing module. In the rainfall generator module the rainfall storm, i.e. the maximum rainfall depth for a fixed duration, is assumed to follow the two components extreme value (TCEV) distribution whose parameters have been estimated at regional scale for Sicily. The catchment response has been modelled by using the Soil Conservation Service-Curve Number (SCS-CN) method, in a semi-distributed form, for the transformation of total rainfall to effective rainfall and simple form of IUH for the flood routing. Here, SCS-CN method is implemented in probabilistic form with respect to prior-to-storm conditions, allowing to relax the classical iso-frequency assumption between rainfall and peak flow. The procedure is tested on six practical case studies where synthetic FFC (flood frequency curve) were obtained starting from model variables distributions by simulating 5000 flood events combining 5000 values of total rainfall depth for the storm duration and AMC (antecedent moisture conditions) conditions. The application of this procedure showed how Monte Carlo simulation technique can reproduce the observed flood frequency curves with reasonable accuracy over a wide range of return periods using a simple and parsimonious approach, limited data input and without any calibration of the rainfall-runoff model.

  18. A method of predicting the energy-absorption capability of composite subfloor beams

    NASA Technical Reports Server (NTRS)

    Farley, Gary L.

    1987-01-01

    A simple method of predicting the energy-absorption capability of composite subfloor beam structure was developed. The method is based upon the weighted sum of the energy-absorption capability of constituent elements of a subfloor beam. An empirical data base of energy absorption results from circular and square cross section tube specimens were used in the prediction capability. The procedure is applicable to a wide range of subfloor beam structure. The procedure was demonstrated on three subfloor beam concepts. Agreement between test and prediction was within seven percent for all three cases.

  19. Let the Rewriter Beware.

    ERIC Educational Resources Information Center

    Charrow, Veda R.

    Translating legal and bureaucratic language into plain, comprehensible English is not amenable to simple rules and procedures. Rewriting comprehensibly requires specialized knowledge about language and an awareness of a number of misconceptions and pitfalls. This paper discusses what not to do in rewriting, based upon rewritten documents presently…

  20. Application of Lagrangian blending functions for grid generation around airplane geometries

    NASA Technical Reports Server (NTRS)

    Abolhassani, Jamshid S.; Sadrehaghighi, Ideen; Tiwari, Surendra N.

    1990-01-01

    A simple procedure was developed and applied for the grid generation around an airplane geometry. This approach is based on a transfinite interpolation with Lagrangian interpolation for the blending functions. A monotonic rational quadratic spline interpolation was employed for the grid distributions.

  1. Boiling Temperature vs. Composition. An Almost-Exact Explicit Equation for a Binary Mixture Following Raoult's Law.

    ERIC Educational Resources Information Center

    Cardinali, Mario Emilio; Giomini, Claudio

    1989-01-01

    Proposes a simple procedure based on an expansion of the exponential terms of Raoult's law by applying it to the case of the benzene-toluene mixture. The results with experimental values are presented as a table. (YP)

  2. Jig-Shape Optimization of a Low-Boom Supersonic Aircraft

    NASA Technical Reports Server (NTRS)

    Pak, Chan-Gi

    2018-01-01

    A simple approach for optimizing the jig-shape is proposed in this study. This simple approach is based on an unconstrained optimization problem and applied to a low-boom supersonic aircraft. In this study, the jig-shape optimization is performed using the two-step approach. First, starting design variables are computed using the least-squares surface fitting technique. Next, the jig-shape is further tuned using a numerical optimization procedure based on an in-house object-oriented optimization tool. During the numerical optimization procedure, a design jig-shape is determined by the baseline jig-shape and basis functions. A total of 12 symmetric mode shapes of the cruise-weight configuration, rigid pitch shape, rigid left and right stabilator rotation shapes, and a residual shape are selected as sixteen basis functions. After three optimization runs, the trim shape error distribution is improved, and the maximum trim shape error of 0.9844 inches of the starting configuration becomes 0.00367 inch by the end of the third optimization run.

  3. A pH Sensor Based on a Stainless Steel Electrode Electrodeposited with Iridium Oxide

    ERIC Educational Resources Information Center

    Martinez, C. C. M.; Madrid, R. E.; Felice, C. J.

    2009-01-01

    A simple procedure to make an iridium oxide (IrO[subscript 2]) electrodeposited pH sensor, that can be used in a chemical, biomedical, or materials laboratory, is presented here. Some exercises, based on this sensor, that can be used to teach important concepts in the field of biomedical, biochemical, tissue, or materials engineering, are also…

  4. Semi-automatic classification of glaciovolcanic landforms: An object-based mapping approach based on geomorphometry

    NASA Astrophysics Data System (ADS)

    Pedersen, G. B. M.

    2016-02-01

    A new object-oriented approach is developed to classify glaciovolcanic landforms (Procedure A) and their landform elements boundaries (Procedure B). It utilizes the principle that glaciovolcanic edifices are geomorphometrically distinct from lava shields and plains (Pedersen and Grosse, 2014), and the approach is tested on data from Reykjanes Peninsula, Iceland. The outlined procedures utilize slope and profile curvature attribute maps (20 m/pixel) and the classified results are evaluated quantitatively through error matrix maps (Procedure A) and visual inspection (Procedure B). In procedure A, the highest obtained accuracy is 94.1%, but even simple mapping procedures provide good results (> 90% accuracy). Successful classification of glaciovolcanic landform element boundaries (Procedure B) is also achieved and this technique has the potential to delineate the transition from intraglacial to subaerial volcanic activity in orthographic view. This object-oriented approach based on geomorphometry overcomes issues with vegetation cover, which has been typically problematic for classification schemes utilizing spectral data. Furthermore, it handles complex edifice outlines well and is easily incorporated into a GIS environment, where results can be edited or fused with other mapping results. The approach outlined here is designed to map glaciovolcanic edifices within the Icelandic neovolcanic zone but may also be applied to similar subaerial or submarine volcanic settings, where steep volcanic edifices are surrounded by flat plains.

  5. Solvent-Ion Interactions in Salt Water: A Simple Experiment.

    ERIC Educational Resources Information Center

    Willey, Joan D.

    1984-01-01

    Describes a procedurally quick, simple, and inexpensive experiment which illustrates the magnitude and some effects of solvent-ion interactions in aqueous solutions. Theoretical information, procedures, and examples of temperature, volume and hydration number calculations are provided. (JN)

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Townsend, D.W.; Linnhoff, B.

    In Part I, criteria for heat engine and heat pump placement in chemical process networks were derived, based on the ''temperature interval'' (T.I) analysis of the heat exchanger network problem. Using these criteria, this paper gives a method for identifying the best outline design for any combined system of chemical process, heat engines, and heat pumps. The method eliminates inferior alternatives early, and positively leads on to the most appropriate solution. A graphical procedure based on the T.I. analysis forms the heart of the approach, and the calculations involved are simple enough to be carried out on, say, a programmablemore » calculator. Application to a case study is demonstrated. Optimization methods based on this procedure are currently under research.« less

  7. Diffusion of Super-Gaussian Profiles

    ERIC Educational Resources Information Center

    Rosenberg, C.-J.; Anderson, D.; Desaix, M.; Johannisson, P.; Lisak, M.

    2007-01-01

    The present analysis describes an analytically simple and systematic approximation procedure for modelling the free diffusive spreading of initially super-Gaussian profiles. The approach is based on a self-similar ansatz for the evolution of the diffusion profile, and the parameter functions involved in the modelling are determined by suitable…

  8. Applications of Lagrangian blending functions for grid generation around airplane geometries

    NASA Technical Reports Server (NTRS)

    Abolhassani, Jamshid S.; Sadrehaghighi, Ideen; Tiwari, Surendra N.; Smith, Robert E.

    1990-01-01

    A simple procedure has been developed and applied for the grid generation around an airplane geometry. This approach is based on a transfinite interpolation with Lagrangian interpolation for the blending functions. A monotonic rational quadratic spline interpolation has been employed for the grid distributions.

  9. Multiplexed capillary microfluidic immunoassay with smartphone data acquisition for parallel mycotoxin detection.

    PubMed

    Machado, Jessica M D; Soares, Ruben R G; Chu, Virginia; Conde, João P

    2018-01-15

    The field of microfluidics holds great promise for the development of simple and portable lab-on-a-chip systems. The use of capillarity as a means of fluidic manipulation in lab-on-a-chip systems can potentially reduce the complexity of the instrumentation and allow the development of user-friendly devices for point-of-need analyses. In this work, a PDMS microchannel-based, colorimetric, autonomous capillary chip provides a multiplexed and semi-quantitative immunodetection assay. Results are acquired using a standard smartphone camera and analyzed with a simple gray scale quantification procedure. The performance of this device was tested for the simultaneous detection of the mycotoxins ochratoxin A (OTA), aflatoxin B1 (AFB1) and deoxynivalenol (DON) which are strictly regulated food contaminants with severe detrimental effects on human and animal health. The multiplexed assay was performed approximately within 10min and the achieved sensitivities of<40, 0.1-0.2 and<10ng/mL for OTA, AFB1 and DON, respectively, fall within the majority of currently enforced regulatory and/or recommended limits. Furthermore, to assess the potential of the device to analyze real samples, the immunoassay was successfully validated for these 3 mycotoxins in a corn-based feed sample after a simple sample preparation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A Recommended Procedure for Estimating the Cosmic-Ray Spectral Parameter of a Simple Power Law With Applications to Detector Design

    NASA Technical Reports Server (NTRS)

    Howell, L. W.

    2001-01-01

    A simple power law model consisting of a single spectral index alpha-1 is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10(exp 13) eV. Two procedures for estimating alpha-1 the method of moments and maximum likelihood (ML), are developed and their statistical performance compared. It is concluded that the ML procedure attains the most desirable statistical properties and is hence the recommended statistical estimation procedure for estimating alpha-1. The ML procedure is then generalized for application to a set of real cosmic-ray data and thereby makes this approach applicable to existing cosmic-ray data sets. Several other important results, such as the relationship between collecting power and detector energy resolution, as well as inclusion of a non-Gaussian detector response function, are presented. These results have many practical benefits in the design phase of a cosmic-ray detector as they permit instrument developers to make important trade studies in design parameters as a function of one of the science objectives. This is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

  11. Laparoscopic insertion of the Moss feeding tube.

    PubMed

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  12. Queueing Network Models for Parallel Processing of Task Systems: an Operational Approach

    NASA Technical Reports Server (NTRS)

    Mak, Victor W. K.

    1986-01-01

    Computer performance modeling of possibly complex computations running on highly concurrent systems is considered. Earlier works in this area either dealt with a very simple program structure or resulted in methods with exponential complexity. An efficient procedure is developed to compute the performance measures for series-parallel-reducible task systems using queueing network models. The procedure is based on the concept of hierarchical decomposition and a new operational approach. Numerical results for three test cases are presented and compared to those of simulations.

  13. Evaluation of Bayesian Sequential Proportion Estimation Using Analyst Labels

    NASA Technical Reports Server (NTRS)

    Lennington, R. K.; Abotteen, K. M. (Principal Investigator)

    1980-01-01

    The author has identified the following significant results. A total of ten Large Area Crop Inventory Experiment Phase 3 blind sites and analyst-interpreter labels were used in a study to compare proportional estimates obtained by the Bayes sequential procedure with estimates obtained from simple random sampling and from Procedure 1. The analyst error rate using the Bayes technique was shown to be no greater than that for the simple random sampling. Also, the segment proportion estimates produced using this technique had smaller bias and mean squared errors than the estimates produced using either simple random sampling or Procedure 1.

  14. Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures.

    PubMed

    Gao, Le; Li, Jian; Wu, Yandan; Yu, Miaohao; Chen, Tian; Shi, Zhixiong; Zhou, Xianqing; Sun, Zhiwei

    2016-11-01

    Two simple and efficient pretreatment procedures have been developed for the simultaneous extraction and cleanup of six novel brominated flame retardants (NBFRs) and eight common polybrominated diphenyl ethers (PBDEs) in human serum. The first sample pretreatment procedure was a quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based approach. An acetone/hexane mixture was employed to isolate the lipid and analytes from the serum with a combination of MgSO 4 and NaCl, followed by a dispersive solid-phase extraction (d-SPE) step using C18 particles as a sorbent. The second sample pretreatment procedure was based on solid-phase extraction. The sample extraction and cleanup were conducted directly on an Oasis HLB SPE column using 5 % aqueous isopropanol, concentrated sulfuric acid, and 10 % aqueous methanol, followed by elution with dichloromethane. The NBFRs and PBDEs were then detected using gas chromatography-negative chemical ionization mass spectrometry (GC-NCI MS). The methods were assessed for repeatability, accuracy, selectivity, limits of detection (LODs), and linearity. The results of spike recovery experiments in fetal bovine serum showed that average recoveries ranged from 77.9 % to 128.8 % with relative standard deviations (RSDs) from 0.73 % to 12.37 % for most of the analytes. The LODs for the analytes in fetal bovine serum ranged from 0.3 to 50.8 pg/mL except for decabromodiphenyl ethane. The proposed method was successfully applied to the determination of the 14 brominated flame retardants in human serum. The two pretreatment procedures described here are simple, accurate, and precise, and are suitable for the routine analysis of human serum. Graphical Abstract Workflow of a QuEChERS-based approach (top) and an SPE-based approach (bottom) for the detection of PBDEs and NBFRs in serum.

  15. A Unified Approach for Solving Nonlinear Regular Perturbation Problems

    ERIC Educational Resources Information Center

    Khuri, S. A.

    2008-01-01

    This article describes a simple alternative unified method of solving nonlinear regular perturbation problems. The procedure is based upon the manipulation of Taylor's approximation for the expansion of the nonlinear term in the perturbed equation. An essential feature of this technique is the relative simplicity used and the associated unified…

  16. Where Are We?

    ERIC Educational Resources Information Center

    Waiveris, Charles; Craine, Timothy V.

    1996-01-01

    Discusses a simple procedure for determining our exact location on Earth based on the motion of celestial bodies and latitude and longitude. This hands-on activity requires students to design and construct an apparatus that will produce accurate measurements. The materials required are a knitting needle, a tape measure, and a sunny day. (AIM)

  17. Manual Solid-Phase Peptide Synthesis of Metallocene-Peptide Bioconjugates

    ERIC Educational Resources Information Center

    Kirin, Srecko I.; Noor, Fozia; Metzler-Nolte, Nils; Mier, Walter

    2007-01-01

    A simple and relatively inexpensive procedure for preparing a biologically active peptide using solid phase peptide synthesis (SPPS) is described. Fourth-year undergraduate students have gained firsthand experience from the solid-phase synthesis techniques and they have become familiar with modern analytical techniques based on the particular…

  18. A soil moisture accounting-procedure with a Richards' equation-based soil texture-dependent parameterization

    USDA-ARS?s Scientific Manuscript database

    Given a time series of potential evapotranspiration and rainfall data, there are at least two approaches for estimating vertical percolation rates. One approach involves solving Richards' equation (RE) with a plant uptake model. An alternative approach involves applying a simple soil moisture accoun...

  19. Simple and rapid screening procedure for 143 new psychoactive substances by liquid chromatography-tandem mass spectrometry.

    PubMed

    Adamowicz, Piotr; Tokarczyk, Bogdan

    2016-07-01

    In recent years, many new psychoactive substances (NPS) from several drug classes have appeared on the drug market. These substances, also known as 'legal highs', belong to different chemical classes. Despite the increasing number of NPS, there are few comprehensive screening methods for their detection in biological specimens. In this context, the purpose of this study was to develop a fast and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening procedure for NPS in blood. The elaborated method allows the simultaneous screening of 143 compounds from different groups (number of compounds): cathinones (36), phenethylamines (26), tryptamines (18), piperazines (9), piperidines (2), synthetic cannabinoids (34), arylalkylamines (7), arylcyclohexylamines (3), aminoindanes (2), and other drugs (6). Blood samples (0.2 mL) were precipitated with acetonitrile (0.6 mL). The separation was achieved with gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 14 min. Detection of all compounds was based on multiple reaction monitoring (MRM) transitions. The total number of transitions monitored in dynamic mode was 432. The whole procedure was rapid and simple. The limits of detection (LODs) estimated for 104 compounds were in the range 0.01-3.09 ng/mL. The extraction recoveries determined for 32 compounds were from 1.8 to 133%. The procedure was successfully applied to the analysis of forensic blood samples in routine casework. The developed method should have wide applicability for rapid screening of new drugs of abuse in forensic or clinical samples. The procedure can be easily expanded for more substances. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Identification of cracks in thick beams with a cracked beam element model

    NASA Astrophysics Data System (ADS)

    Hou, Chuanchuan; Lu, Yong

    2016-12-01

    The effect of a crack on the vibration of a beam is a classical problem, and various models have been proposed, ranging from the basic stiffness reduction method to the more sophisticated model involving formulation based on the additional flexibility due to a crack. However, in the damage identification or finite element model updating applications, it is still common practice to employ a simple stiffness reduction factor to represent a crack in the identification process, whereas the use of a more realistic crack model is rather limited. In this paper, the issues with the simple stiffness reduction method, particularly concerning thick beams, are highlighted along with a review of several other crack models. A robust finite element model updating procedure is then presented for the detection of cracks in beams. The description of the crack parameters is based on the cracked beam flexibility formulated by means of the fracture mechanics, and it takes into consideration of shear deformation and coupling between translational and longitudinal vibrations, and thus is particularly suitable for thick beams. The identification procedure employs a global searching technique using Genetic Algorithms, and there is no restriction on the location, severity and the number of cracks to be identified. The procedure is verified to yield satisfactory identification for practically any configurations of cracks in a beam.

  1. Robust decentralized power system controller design: Integrated approach

    NASA Astrophysics Data System (ADS)

    Veselý, Vojtech

    2017-09-01

    A unique approach to the design of gain scheduled controller (GSC) is presented. The proposed design procedure is based on the Bellman-Lyapunov equation, guaranteed cost and robust stability conditions using the parameter dependent quadratic stability approach. The obtained feasible design procedures for robust GSC design are in the form of BMI with guaranteed convex stability conditions. The obtained design results and their properties are illustrated in the simultaneously design of controllers for simple model (6-order) turbogenerator. The results of the obtained design procedure are a PI automatic voltage regulator (AVR) for synchronous generator, a PI governor controller and a power system stabilizer for excitation system.

  2. A Simple Method for Automated Equilibration Detection in Molecular Simulations.

    PubMed

    Chodera, John D

    2016-04-12

    Molecular simulations intended to compute equilibrium properties are often initiated from configurations that are highly atypical of equilibrium samples, a practice which can generate a distinct initial transient in mechanical observables computed from the simulation trajectory. Traditional practice in simulation data analysis recommends this initial portion be discarded to equilibration, but no simple, general, and automated procedure for this process exists. Here, we suggest a conceptually simple automated procedure that does not make strict assumptions about the distribution of the observable of interest in which the equilibration time is chosen to maximize the number of effectively uncorrelated samples in the production timespan used to compute equilibrium averages. We present a simple Python reference implementation of this procedure and demonstrate its utility on typical molecular simulation data.

  3. A simple method for automated equilibration detection in molecular simulations

    PubMed Central

    Chodera, John D.

    2016-01-01

    Molecular simulations intended to compute equilibrium properties are often initiated from configurations that are highly atypical of equilibrium samples, a practice which can generate a distinct initial transient in mechanical observables computed from the simulation trajectory. Traditional practice in simulation data analysis recommends this initial portion be discarded to equilibration, but no simple, general, and automated procedure for this process exists. Here, we suggest a conceptually simple automated procedure that does not make strict assumptions about the distribution of the observable of interest, in which the equilibration time is chosen to maximize the number of effectively uncorrelated samples in the production timespan used to compute equilibrium averages. We present a simple Python reference implementation of this procedure, and demonstrate its utility on typical molecular simulation data. PMID:26771390

  4. Extending cluster Lot Quality Assurance Sampling designs for surveillance programs

    PubMed Central

    Hund, Lauren; Pagano, Marcello

    2014-01-01

    Lot quality assurance sampling (LQAS) has a long history of applications in industrial quality control. LQAS is frequently used for rapid surveillance in global health settings, with areas classified as poor or acceptable performance based on the binary classification of an indicator. Historically, LQAS surveys have relied on simple random samples from the population; however, implementing two-stage cluster designs for surveillance sampling is often more cost-effective than simple random sampling. By applying survey sampling results to the binary classification procedure, we develop a simple and flexible non-parametric procedure to incorporate clustering effects into the LQAS sample design to appropriately inflate the sample size, accommodating finite numbers of clusters in the population when relevant. We use this framework to then discuss principled selection of survey design parameters in longitudinal surveillance programs. We apply this framework to design surveys to detect rises in malnutrition prevalence in nutrition surveillance programs in Kenya and South Sudan, accounting for clustering within villages. By combining historical information with data from previous surveys, we design surveys to detect spikes in the childhood malnutrition rate. PMID:24633656

  5. Endoscopic-assisted osteotomies for the treatment of craniosynostosis.

    PubMed

    Hinojosa, J; Esparza, J; Muñoz, M J

    2007-12-01

    The development of multidisciplinar units for Craniofacial Surgery has led to better postoperative results and a considerable decrease in morbidity in the treatment of complex craniofacial patients. Standard correction of craniosynostosis involves calvarial remodeling, often considerable blood losses that need to be replaced and lengthy hospital stay. The use of minimally invasive techniques for the correction of some of these malformations are widespread and allows the surgeon to minimize the incidence of complications by means of a decreased surgical time, blood salvage, and shortening of postoperative hospitalization in comparison to conventional craniofacial techniques. Simple and milder craniosynostosis are best approached by endoscopy-assisted osteotomies and render the best results. Extended procedures other than simple suturectomies have been described for more severe patients. Different osteotomies resembling standard fronto-orbital have been developed for the correction, and the use of postoperative cranial orthesis may improve the final cosmetic appearance. Thus, endoscopic-assisted procedures differ from the simple strategy of single suture resection that rendered insufficient results in the past, and different approaches can be tailored to solve these cases in patients in the setting of a case-to-case bases.

  6. How-to-Do-It: A Simple DNA Isolation Technique Using Halophilic Bacteria.

    ERIC Educational Resources Information Center

    Guilfoile, Patrick

    1989-01-01

    Described is a simple technique for isolating DNA from halophilic bacteria. Materials, procedure, and additional experiments are outlined. It is stated that the DNA obtained will be somewhat contaminated with cellular proteins and RNA. Offers a procedure for greater purification. (RT)

  7. Optimal ancilla-free Pauli+V circuits for axial rotations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blass, Andreas; Bocharov, Alex; Gurevich, Yuri

    We address the problem of optimal representation of single-qubit rotations in a certain unitary basis consisting of the so-called V gates and Pauli matrices. The V matrices were proposed by Lubotsky, Philips, and Sarnak [Commun. Pure Appl. Math. 40, 401–420 (1987)] as a purely geometric construct in 1987 and recently found applications in quantum computation. They allow for exceptionally simple quantum circuit synthesis algorithms based on quaternionic factorization. We adapt the deterministic-search technique initially proposed by Ross and Selinger to synthesize approximating Pauli+V circuits of optimal depth for single-qubit axial rotations. Our synthesis procedure based on simple SL{sub 2}(ℤ) geometrymore » is almost elementary.« less

  8. Predicting a future lifetime through Box-Cox transformation.

    PubMed

    Yang, Z

    1999-09-01

    In predicting a future lifetime based on a sample of past lifetimes, the Box-Cox transformation method provides a simple and unified procedure that is shown in this article to meet or often outperform the corresponding frequentist solution in terms of coverage probability and average length of prediction intervals. Kullback-Leibler information and second-order asymptotic expansion are used to justify the Box-Cox procedure. Extensive Monte Carlo simulations are also performed to evaluate the small sample behavior of the procedure. Certain popular lifetime distributions, such as Weibull, inverse Gaussian and Birnbaum-Saunders are served as illustrative examples. One important advantage of the Box-Cox procedure lies in its easy extension to linear model predictions where the exact frequentist solutions are often not available.

  9. Omega "Ω" Pulley Plasty for Surgical Management of DeQuervain's Disease.

    PubMed

    Bakhach, Joseph; Chaya, Bachar; Papazian, Nazareth

    2018-06-01

    DeQuervain tenosynovitis, refractory to medical conservative treatment, has been traditionally treated by a simple division of the pulley, a procedure associated with several complications. Many authors attempted to prevent these complications by describing techniques of pulley reconstruction after its release necessitating suturing the different flaps and subsequently promoting extensor tendons adhesions. The authors present an alternative procedure for the first extensor compartment pulley decompression: "Omegaplasty". 25 Patients with 29 DeQuervain tenosynovitis cases were enrolled in a prospective, nonrandomized clinical trial from 2012 to 2016. At enrollment they were offered the option of Omegaplasty as a surgical treatment modality for their cases. The procedure is based on liberating the anterior attachment of the pulley from the anterior lip of the styloïd process while respecting its continuity with the periosteal flap as well as promoting expansion of the tunnel volume. All operated patients were evaluated using the "Opposition Kapandji Score". The authors present the results of 29 different "Omegaplasty" procedures. Based on the Kapandji opposition score, twenty cases scored 10/10 while the remaining nine cases yielded an 8/10 score each. The described technique is simple, reliable and respects the extensor tendons gliding physiology and biodynamics. By preserving the anatomical continuity of the first extensor compartment pulley at the wrist, the risk of adhesion formation is reduced. The preliminary results are encouraging and provide the "Ω" plasty the potential to be considered as a surgical option for treatment of De Quervain Tenosynovitis.

  10. A simple signaling rule for variable life-adjusted display derived from an equivalent risk-adjusted CUSUM chart.

    PubMed

    Wittenberg, Philipp; Gan, Fah Fatt; Knoth, Sven

    2018-04-17

    The variable life-adjusted display (VLAD) is the first risk-adjusted graphical procedure proposed in the literature for monitoring the performance of a surgeon. It displays the cumulative sum of expected minus observed deaths. It has since become highly popular because the statistic plotted is easy to understand. But it is also easy to misinterpret a surgeon's performance by utilizing the VLAD, potentially leading to grave consequences. The problem of misinterpretation is essentially caused by the variance of the VLAD's statistic that increases with sample size. In order for the VLAD to be truly useful, a simple signaling rule is desperately needed. Various forms of signaling rules have been developed, but they are usually quite complicated. Without signaling rules, making inferences using the VLAD alone is difficult if not misleading. In this paper, we establish an equivalence between a VLAD with V-mask and a risk-adjusted cumulative sum (RA-CUSUM) chart based on the difference between the estimated probability of death and surgical outcome. Average run length analysis based on simulation shows that this particular RA-CUSUM chart has similar performance as compared to the established RA-CUSUM chart based on the log-likelihood ratio statistic obtained by testing the odds ratio of death. We provide a simple design procedure for determining the V-mask parameters based on a resampling approach. Resampling from a real data set ensures that these parameters can be estimated appropriately. Finally, we illustrate the monitoring of a real surgeon's performance using VLAD with V-mask. Copyright © 2018 John Wiley & Sons, Ltd.

  11. The Productivity Dilemma in Workplace Health Promotion.

    PubMed

    Cherniack, Martin

    2015-01-01

    Worksite-based programs to improve workforce health and well-being (Workplace Health Promotion (WHP)) have been advanced as conduits for improved worker productivity and decreased health care costs. There has been a countervailing health economics contention that return on investment (ROI) does not merit preventive health investment. METHODS/PROCEDURES: Pertinent studies were reviewed and results reconsidered. A simple economic model is presented based on conventional and alternate assumptions used in cost benefit analysis (CBA), such as discounting and negative value. The issues are presented in the format of 3 conceptual dilemmas. In some occupations such as nursing, the utility of patient survival and staff health is undervalued. WHP may miss important components of work related health risk. Altering assumptions on discounting and eliminating the drag of negative value radically change the CBA value. Simple monetization of a work life and calculation of return on workforce health investment as a simple alternate opportunity involve highly selective interpretations of productivity and utility.

  12. Guidance concepts for time-based flight operations

    NASA Technical Reports Server (NTRS)

    Vicroy, Dan D.

    1990-01-01

    Airport congestion and the associated delays are severe in today's airspace system and are expected to increase. NASA and the FAA is investigating various methods of alleviating this problem through new technology and operational procedures. One concept for improving airspace productivity is time-based control of aircraft. Research to date has focused primarily on the development of time-based flight management systems and Air Traffic Control operational procedures. Flight operations may, however, require special onboard guidance in order to satisfy the Air Traffic Control imposed time constraints. The results are presented of a simulation study aimed at evaluating several time-based guidance concepts in terms of tracking performance, pilot workload, and subjective preference. The guidance concepts tested varied in complexity from simple digital time-error feedback to an advanced time-referenced-energy guidance scheme.

  13. Conjugated Gammadion Chiral Metamaterial with Uniaxial Optical Activity and Negative Refractive Index

    DTIC Science & Technology

    2011-01-10

    in Fig. 4, we discuss a procedure of transmutation from the simple -particle chiral element to the conjugated gammadion chiral metamaterial. The...the transmutation from the simple -particle chiral element to the conjugated gammadion chiral metamaterial. The procedure shows how the magnetic or

  14. A simple procedure for the estimation of neutron skyshine from proton accelerators.

    PubMed

    Stevenson, G R; Thomas, R H

    1984-01-01

    Recent calculations of neutron diffusion at an air/ground interface have enabled the establishment of a very simple procedure for estimating neutron dose equivalent at large distances from proton accelerators in the energy range 10 MeV to several tens of GeV.

  15. A novel tree-based procedure for deciphering the genomic spectrum of clinical disease entities.

    PubMed

    Mbogning, Cyprien; Perdry, Hervé; Toussile, Wilson; Broët, Philippe

    2014-01-01

    Dissecting the genomic spectrum of clinical disease entities is a challenging task. Recursive partitioning (or classification trees) methods provide powerful tools for exploring complex interplay among genomic factors, with respect to a main factor, that can reveal hidden genomic patterns. To take confounding variables into account, the partially linear tree-based regression (PLTR) model has been recently published. It combines regression models and tree-based methodology. It is however computationally burdensome and not well suited for situations for which a large number of exploratory variables is expected. We developed a novel procedure that represents an alternative to the original PLTR procedure, and considered different selection criteria. A simulation study with different scenarios has been performed to compare the performances of the proposed procedure to the original PLTR strategy. The proposed procedure with a Bayesian Information Criterion (BIC) achieved good performances to detect the hidden structure as compared to the original procedure. The novel procedure was used for analyzing patterns of copy-number alterations in lung adenocarcinomas, with respect to Kirsten Rat Sarcoma Viral Oncogene Homolog gene (KRAS) mutation status, while controlling for a cohort effect. Results highlight two subgroups of pure or nearly pure wild-type KRAS tumors with particular copy-number alteration patterns. The proposed procedure with a BIC criterion represents a powerful and practical alternative to the original procedure. Our procedure performs well in a general framework and is simple to implement.

  16. Complications of Minimally Invasive Cosmetic Procedures: Prevention and Management

    PubMed Central

    Levy, Lauren L; Emer, Jason J

    2012-01-01

    Over the past decade, facial rejuvenation procedures to circumvent traditional surgery have become increasingly popular. Office-based, minimally invasive procedures can promote a youthful appearance with minimal downtime and low risk of complications. Injectable botulinum toxin (BoNT), soft-tissue fillers, and chemical peels are among the most popular non-invasive rejuvenation procedures, and each has unique applications for improving facial aesthetics. Despite the simplicity and reliability of office-based procedures, complications can occur even with an astute and experienced injector. The goal of any procedure is to perform it properly and safely; thus, early recognition of complications when they do occur is paramount in dictating prevention of long-term sequelae. The most common complications from BoNT and soft-tissue filler injection are bruising, erythema and pain. With chemical peels, it is not uncommon to have erythema, irritation and burning. Fortunately, these side effects are normally transient and have simple remedies. More serious complications include muscle paralysis from BoNT, granuloma formation from soft-tissue filler placement and scarring from chemical peels. Thankfully, these complications are rare and can be avoided with excellent procedure technique, knowledge of facial anatomy, proper patient selection, and appropriate pre- and post-skin care. This article reviews complications of office-based, minimally invasive procedures, with emphasis on prevention and management. Practitioners providing these treatments should be well versed in this subject matter in order to deliver the highest quality care. PMID:23060707

  17. Simultaneous determination of selected biogenic amines in alcoholic beverage samples by isotachophoretic and chromatographic methods.

    PubMed

    Jastrzębska, Aneta; Piasta, Anna; Szłyk, Edward

    2014-01-01

    A simple and useful method for the determination of biogenic amines in beverage samples based on isotachophoretic separation is described. The proposed procedure permitted simultaneous analysis of histamine, tyramine, cadaverine, putrescine, tryptamine, 2-phenylethylamine, spermine and spermidine. The data presented demonstrate the utility, simplicity, flexibility, sensitivity and environmentally friendly character of the proposed method. The precision of the method expressed as coefficient of variations varied from 0.1% to 5.9% for beverage samples, whereas recoveries varied from 91% to 101%. The results for the determination of biogenic amines were compared with an HPLC procedure based on a pre-column derivatisation reaction of biogenic amines with dansyl chloride. Furthermore, the derivatisation procedure was optimised by verification of concentration and pH of the buffer, the addition of organic solvents, reaction time and temperature.

  18. Using Response Interruption and Redirection to Reduce Vocal Stereotypy

    ERIC Educational Resources Information Center

    Sheehey, Patricia H.; Wells, Jenny C.

    2018-01-01

    Response interruption and redirection, commonly referred to as RIR, is an evidence-based intervention that has been demonstrated to quickly reduce moderate to high levels of vocal stereotypy in children with autism spectrum disorder. The RIR intervention is a simple, three-step procedure that can be embedded in classroom instruction with minimal…

  19. A Materials Index--Its Storage, Retrieval, and Display

    ERIC Educational Resources Information Center

    Rosen, Carol Z.

    1973-01-01

    An experimental procedure for indexing physical materials based on simple syntactical rules was tested by encoding the materials in the journal, Applied Physics Letters,'' to produce a materials index. The syntax and numerous examples together with an indication of the method by which retrieval can be effected are presented. (5 references)…

  20. Sorption of Triangular Silver Nanoplates on Polyurethane Foam

    NASA Astrophysics Data System (ADS)

    Furletov, A. A.; Apyari, V. V.; Garshev, A. V.; Volkov, P. A.; Tolmacheva, V. V.; Dmitrienko, S. G.

    2018-02-01

    The sorption of triangular silver nanoplates on polyurethane foam is investigated as a procedure for creating a nanocomposite sensing material for subsequent use in optical means of chemical analysis. Triangular silver nanoplates are synthesized and characterized, and a simple sorption technique for the formation of a composite material based on these nanoplates is proposed.

  1. Model compilation: An approach to automated model derivation

    NASA Technical Reports Server (NTRS)

    Keller, Richard M.; Baudin, Catherine; Iwasaki, Yumi; Nayak, Pandurang; Tanaka, Kazuo

    1990-01-01

    An approach is introduced to automated model derivation for knowledge based systems. The approach, model compilation, involves procedurally generating the set of domain models used by a knowledge based system. With an implemented example, how this approach can be used to derive models of different precision and abstraction is illustrated, and models are tailored to different tasks, from a given set of base domain models. In particular, two implemented model compilers are described, each of which takes as input a base model that describes the structure and behavior of a simple electromechanical device, the Reaction Wheel Assembly of NASA's Hubble Space Telescope. The compilers transform this relatively general base model into simple task specific models for troubleshooting and redesign, respectively, by applying a sequence of model transformations. Each transformation in this sequence produces an increasingly more specialized model. The compilation approach lessens the burden of updating and maintaining consistency among models by enabling their automatic regeneration.

  2. Simple projects guidebook : federal-aid procedure for simple projects

    DOT National Transportation Integrated Search

    2002-06-01

    Experience has shown that a simple project generally 1) does not have any right-of-way involvement and 2) has a Programmatic Categorical Exclusion or Categorical Exclusion environmental determination. Page 7 outlines the definition of simple projects...

  3. Maximized gust loads for a nonlinear airplane using matched filter theory and constrained optimization

    NASA Technical Reports Server (NTRS)

    Scott, Robert C.; Pototzky, Anthony S.; Perry, Boyd, III

    1991-01-01

    Two matched filter theory based schemes are described and illustrated for obtaining maximized and time correlated gust loads for a nonlinear aircraft. The first scheme is computationally fast because it uses a simple 1-D search procedure to obtain its answers. The second scheme is computationally slow because it uses a more complex multi-dimensional search procedure to obtain its answers, but it consistently provides slightly higher maximum loads than the first scheme. Both schemes are illustrated with numerical examples involving a nonlinear control system.

  4. Maximized gust loads for a nonlinear airplane using matched filter theory and constrained optimization

    NASA Technical Reports Server (NTRS)

    Scott, Robert C.; Perry, Boyd, III; Pototzky, Anthony S.

    1991-01-01

    This paper describes and illustrates two matched-filter-theory based schemes for obtaining maximized and time-correlated gust-loads for a nonlinear airplane. The first scheme is computationally fast because it uses a simple one-dimensional search procedure to obtain its answers. The second scheme is computationally slow because it uses a more complex multidimensional search procedure to obtain its answers, but it consistently provides slightly higher maximum loads than the first scheme. Both schemes are illustrated with numerical examples involving a nonlinear control system.

  5. ViSimpl: Multi-View Visual Analysis of Brain Simulation Data

    PubMed Central

    Galindo, Sergio E.; Toharia, Pablo; Robles, Oscar D.; Pastor, Luis

    2016-01-01

    After decades of independent morphological and functional brain research, a key point in neuroscience nowadays is to understand the combined relationships between the structure of the brain and its components and their dynamics on multiple scales, ranging from circuits of neurons at micro or mesoscale to brain regions at macroscale. With such a goal in mind, there is a vast amount of research focusing on modeling and simulating activity within neuronal structures, and these simulations generate large and complex datasets which have to be analyzed in order to gain the desired insight. In such context, this paper presents ViSimpl, which integrates a set of visualization and interaction tools that provide a semantic view of brain data with the aim of improving its analysis procedures. ViSimpl provides 3D particle-based rendering that allows visualizing simulation data with their associated spatial and temporal information, enhancing the knowledge extraction process. It also provides abstract representations of the time-varying magnitudes supporting different data aggregation and disaggregation operations and giving also focus and context clues. In addition, ViSimpl tools provide synchronized playback control of the simulation being analyzed. Finally, ViSimpl allows performing selection and filtering operations relying on an application called NeuroScheme. All these views are loosely coupled and can be used independently, but they can also work together as linked views, both in centralized and distributed computing environments, enhancing the data exploration and analysis procedures. PMID:27774062

  6. ViSimpl: Multi-View Visual Analysis of Brain Simulation Data.

    PubMed

    Galindo, Sergio E; Toharia, Pablo; Robles, Oscar D; Pastor, Luis

    2016-01-01

    After decades of independent morphological and functional brain research, a key point in neuroscience nowadays is to understand the combined relationships between the structure of the brain and its components and their dynamics on multiple scales, ranging from circuits of neurons at micro or mesoscale to brain regions at macroscale. With such a goal in mind, there is a vast amount of research focusing on modeling and simulating activity within neuronal structures, and these simulations generate large and complex datasets which have to be analyzed in order to gain the desired insight. In such context, this paper presents ViSimpl, which integrates a set of visualization and interaction tools that provide a semantic view of brain data with the aim of improving its analysis procedures. ViSimpl provides 3D particle-based rendering that allows visualizing simulation data with their associated spatial and temporal information, enhancing the knowledge extraction process. It also provides abstract representations of the time-varying magnitudes supporting different data aggregation and disaggregation operations and giving also focus and context clues. In addition, ViSimpl tools provide synchronized playback control of the simulation being analyzed. Finally, ViSimpl allows performing selection and filtering operations relying on an application called NeuroScheme. All these views are loosely coupled and can be used independently, but they can also work together as linked views, both in centralized and distributed computing environments, enhancing the data exploration and analysis procedures.

  7. Detection and Characterization of Viral Species/Subspecies Using Isothermal Recombinase Polymerase Amplification (RPA) Assays.

    PubMed

    Glais, Laurent; Jacquot, Emmanuel

    2015-01-01

    Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.

  8. Identification of site frequencies from building records

    USGS Publications Warehouse

    Celebi, M.

    2003-01-01

    A simple procedure to identify site frequencies using earthquake response records from roofs and basements of buildings is presented. For this purpose, data from five different buildings are analyzed using only spectral analyses techniques. Additional data such as free-field records in close proximity to the buildings and site characterization data are also used to estimate site frequencies and thereby to provide convincing evidence and confirmation of the site frequencies inferred from the building records. Furthermore, simple code-formula is used to calculate site frequencies and compare them with the identified site frequencies from records. Results show that the simple procedure is effective in identification of site frequencies and provides relatively reliable estimates of site frequencies when compared with other methods. Therefore the simple procedure for estimating site frequencies using earthquake records can be useful in adding to the database of site frequencies. Such databases can be used to better estimate site frequencies of those sites with similar geological structures.

  9. Finite-sample and asymptotic sign-based tests for parameters of non-linear quantile regression with Markov noise

    NASA Astrophysics Data System (ADS)

    Sirenko, M. A.; Tarasenko, P. F.; Pushkarev, M. I.

    2017-01-01

    One of the most noticeable features of sign-based statistical procedures is an opportunity to build an exact test for simple hypothesis testing of parameters in a regression model. In this article, we expanded a sing-based approach to the nonlinear case with dependent noise. The examined model is a multi-quantile regression, which makes it possible to test hypothesis not only of regression parameters, but of noise parameters as well.

  10. A Focusing Method in the Calibration Process of Image Sensors Based on IOFBs

    PubMed Central

    Fernández, Pedro R.; Lázaro, José L.; Gardel, Alfredo; Cano, Ángel E.; Bravo, Ignacio

    2010-01-01

    A focusing procedure in the calibration process of image sensors based on Incoherent Optical Fiber Bundles (IOFBs) is described using the information extracted from fibers. These procedures differ from any other currently known focusing method due to the non spatial in-out correspondence between fibers, which produces a natural codification of the image to transmit. Focus measuring is essential prior to carrying out calibration in order to guarantee accurate processing and decoding. Four algorithms have been developed to estimate the focus measure; two methods based on mean grey level, and the other two based on variance. In this paper, a few simple focus measures are defined and compared. Some experimental results referred to the focus measure and the accuracy of the developed methods are discussed in order to demonstrate its effectiveness. PMID:22315526

  11. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    NASA Astrophysics Data System (ADS)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  12. Selecting Statistical Quality Control Procedures for Limiting the Impact of Increases in Analytical Random Error on Patient Safety.

    PubMed

    Yago, Martín

    2017-05-01

    QC planning based on risk management concepts can reduce the probability of harming patients due to an undetected out-of-control error condition. It does this by selecting appropriate QC procedures to decrease the number of erroneous results reported. The selection can be easily made by using published nomograms for simple QC rules when the out-of-control condition results in increased systematic error. However, increases in random error also occur frequently and are difficult to detect, which can result in erroneously reported patient results. A statistical model was used to construct charts for the 1 ks and X /χ 2 rules. The charts relate the increase in the number of unacceptable patient results reported due to an increase in random error with the capability of the measurement procedure. They thus allow for QC planning based on the risk of patient harm due to the reporting of erroneous results. 1 ks Rules are simple, all-around rules. Their ability to deal with increases in within-run imprecision is minimally affected by the possible presence of significant, stable, between-run imprecision. X /χ 2 rules perform better when the number of controls analyzed during each QC event is increased to improve QC performance. Using nomograms simplifies the selection of statistical QC procedures to limit the number of erroneous patient results reported due to an increase in analytical random error. The selection largely depends on the presence or absence of stable between-run imprecision. © 2017 American Association for Clinical Chemistry.

  13. Manpower Information Manual. A Manual for Local Planning.

    ERIC Educational Resources Information Center

    Allred, Marcus D.; Myers, Christine F.

    The step-by-step procedures contained in this manual are intended to develop a simple information system that can be used to collect and process the best possible factual data on the manpower needs of the community served by an educational institution, so that long-range planning of vocational curriculum and guidance can be based on what the jobs…

  14. JJ Stent Removal under Ultrasound Guidance in Women: It is Simple and Safe.

    PubMed

    Amer, Bernard; Gupta, Sandeep; Kanwar, Vijayendra S; Lodh, Bijit; Khumukcham, Somarendra; Akoijam, Kaku Singh

    2014-12-01

    With the increase in number of patients treated for urological problems with endoscopic procedures, the number of patients with JJ stent is also increasing. The amount of workload thus incurred multiplies, even to the point that, sometimes we waste more time in the operating room removing JJ stents than the actual endourological procedures. Here in our institute, we have devised a very simple and effective way of removing JJ stents in women and also determined the efficacy, safety and cost of JJ stent removal under ultrasound guidance in women in comparison to cystoscopic removal. Two hundred women attending the Department of Urology from July 2012 to July 2013 at RIMS hospital were randomly divided into two arms. One hundred women had their JJ stent removed with cystoscope and another 100 women had their JJ stent removed under ultrasound guidance using simple surgical tools available at the hospital. The primary comparative points were waiting time for operating room appointment date, cost of the procedure, time taken for the procedure, discomfort or pain felt by the patient and urethral injuries. In all the parameters, stent removal under ultrasound guidance was significantly better except for urethral injuries where both the procedures had similar outcomes. We concluded that JJ stent removal under ultrasound guidance in women was simple, effective and safe.

  15. Gene Polymorphism Studies in a Teaching Laboratory

    NASA Astrophysics Data System (ADS)

    Shultz, Jeffry

    2009-02-01

    I present a laboratory procedure for illustrating transcription, post-transcriptional modification, gene conservation, and comparative genetics for use in undergraduate biology education. Students are individually assigned genes in a targeted biochemical pathway, for which they design and test polymerase chain reaction (PCR) primers. In this example, students used genes annotated for the steroid biosynthesis pathway in soybean. The authoritative Kyoto encyclopedia of genes and genomes (KEGG) interactive database and other online resources were used to design primers based first on soybean expressed sequence tags (ESTs), then on ESTs from an alternate organism if soybean sequence was unavailable. Students designed a total of 50 gene-based primer pairs (37 soybean, 13 alternative) and tested these for polymorphism state and similarity between two soybean and two pea lines. Student assessment was based on acquisition of laboratory skills and successful project completion. This simple procedure illustrates conservation of genes and is not limited to soybean or pea. Cost per student estimates are included, along with a detailed protocol and flow diagram of the procedure.

  16. Tensor fascia lata flap versus tensor fascia lata perforator-based island flap for the coverage of extensive trochanteric pressure sores.

    PubMed

    Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon

    2013-06-01

    Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.

  17. Isolating the Effects of Training Using Simple Regression Analysis: An Example of the Procedure.

    ERIC Educational Resources Information Center

    Waugh, C. Keith

    This paper provides a case example of simple regression analysis, a forecasting procedure used to isolate the effects of training from an identified extraneous variable. This case example focuses on results of a three-day sales training program to improve bank loan officers' knowledge, skill-level, and attitude regarding solicitation and sale of…

  18. 76 FR 56263 - Titles II and XVI: Documenting and Evaluating Disability in Young Adults

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-12

    ... carrying out simple instructions and work procedures during a school-sponsored work experience; Difficulty... instructions; Make simple work-related judgments typically required for unskilled work; Respond appropriately... ability to hear and understand simple oral messages, including instructions, and to communicate simple...

  19. A simple formula for predicting claw volume of cattle.

    PubMed

    Scott, T D; Naylor, J M; Greenough, P R

    1999-11-01

    The object of this study was to develop a simple method for accurately calculating the volume of bovine claws under field conditions. The digits of 30 slaughterhouse beef cattle were examined and the following four linear measurements taken from each pair of claws: (1) the length of the dorsal surface of the claw (Toe); (2) the length of the coronary band (CorBand); (3) the length of the bearing surface (Base); and (4) the height of the claw at the abaxial groove (AbaxGr). Measurements of claw volume using a simple hydrometer were highly repeatable (r(2)= 0.999) and could be calculated from linear measurements using the formula:Claw Volume (cm(3)) = (17.192 x Base) + (7.467 x AbaxGr) + 45.270 x (CorBand) - 798.5This formula was found to be accurate (r(2)= 0.88) when compared to volume data derived from a hydrometer displacement procedure. The front claws occupied 54% of the total volume compared to 46% for the hind claws. Copyright 1999 Harcourt Publishers Ltd.

  20. The Productivity Dilemma in Workplace Health Promotion

    PubMed Central

    Cherniack, Martin

    2015-01-01

    Background. Worksite-based programs to improve workforce health and well-being (Workplace Health Promotion (WHP)) have been advanced as conduits for improved worker productivity and decreased health care costs. There has been a countervailing health economics contention that return on investment (ROI) does not merit preventive health investment. Methods/Procedures. Pertinent studies were reviewed and results reconsidered. A simple economic model is presented based on conventional and alternate assumptions used in cost benefit analysis (CBA), such as discounting and negative value. The issues are presented in the format of 3 conceptual dilemmas. Principal Findings. In some occupations such as nursing, the utility of patient survival and staff health is undervalued. WHP may miss important components of work related health risk. Altering assumptions on discounting and eliminating the drag of negative value radically change the CBA value. Significance. Simple monetization of a work life and calculation of return on workforce health investment as a simple alternate opportunity involve highly selective interpretations of productivity and utility. PMID:26380374

  1. Constitutive error based parameter estimation technique for plate structures using free vibration signatures

    NASA Astrophysics Data System (ADS)

    Guchhait, Shyamal; Banerjee, Biswanath

    2018-04-01

    In this paper, a variant of constitutive equation error based material parameter estimation procedure for linear elastic plates is developed from partially measured free vibration sig-natures. It has been reported in many research articles that the mode shape curvatures are much more sensitive compared to mode shape themselves to localize inhomogeneity. Complying with this idea, an identification procedure is framed as an optimization problem where the proposed cost function measures the error in constitutive relation due to incompatible curvature/strain and moment/stress fields. Unlike standard constitutive equation error based procedure wherein a solution of a couple system is unavoidable in each iteration, we generate these incompatible fields via two linear solves. A simple, yet effective, penalty based approach is followed to incorporate measured data. The penalization parameter not only helps in incorporating corrupted measurement data weakly but also acts as a regularizer against the ill-posedness of the inverse problem. Explicit linear update formulas are then developed for anisotropic linear elastic material. Numerical examples are provided to show the applicability of the proposed technique. Finally, an experimental validation is also provided.

  2. Poly(ethylene oxide) functionalization

    DOEpatents

    Pratt, Russell Clayton

    2014-04-08

    A simple procedure is provided by which the hydroxyl termini of poly(ethylene oxide) can be appended with functional groups to a useful extent by reaction and precipitation. The polymer is dissolved in warmed toluene, treated with an excess of organic base and somewhat less of an excess of a reactive acylating reagent, reacted for several hours, then precipitated in isopropanol so that the product can be isolated as a solid, and salt byproducts are washed away. This procedure enables functionalization of the polymer while not requiring laborious purification steps such as solvent-solvent extraction or dialysis to remove undesirable side products.

  3. Optimisation of solid-phase microextraction coupled to HPLC-UV for the determination of organochlorine pesticides and their metabolites in environmental liquid samples.

    PubMed

    Torres Padrón, M E; Sosa Ferrera, Z; Santana Rodríguez, J J

    2006-09-01

    A solid-phase microextraction (SPME) procedure using two commercial fibers coupled with high-performance liquid chromatography (HPLC) is presented for the extraction and determination of organochlorine pesticides in water samples. We have evaluated the extraction efficiency of this kind of compound using two different fibers: 60-mum polydimethylsiloxane-divinylbenzene (PDMS-DVB) and Carbowax/TPR-100 (CW/TPR). Parameters involved in the extraction and desorption procedures (e.g. extraction time, ionic strength, extraction temperature, desorption and soaking time) were studied and optimized to achieve the maximum efficiency. Results indicate that both PDMS-DVB and CW/TPR fibers are suitable for the extraction of this type of compound, and a simple calibration curve method based on simple aqueous standards can be used. All the correlation coefficients were better than 0.9950, and the RSDs ranged from 7% to 13% for 60-mum PDMS-DVB fiber and from 3% to 10% for CW/TPR fiber. Optimized procedures were applied to the determination of a mixture of six organochlorine pesticides in environmental liquid samples (sea, sewage and ground waters), employing HPLC with UV-diode array detector.

  4. Developmental dissociation in the neural responses to simple multiplication and subtraction problems

    PubMed Central

    Prado, Jérôme; Mutreja, Rachna; Booth, James R.

    2014-01-01

    Mastering single-digit arithmetic during school years is commonly thought to depend upon an increasing reliance on verbally memorized facts. An alternative model, however, posits that fluency in single-digit arithmetic might also be achieved via the increasing use of efficient calculation procedures. To test between these hypotheses, we used a cross-sectional design to measure the neural activity associated with single-digit subtraction and multiplication in 34 children from 2nd to 7th grade. The neural correlates of language and numerical processing were also identified in each child via localizer scans. Although multiplication and subtraction were undistinguishable in terms of behavior, we found a striking developmental dissociation in their neural correlates. First, we observed grade-related increases of activity for multiplication, but not for subtraction, in a language-related region of the left temporal cortex. Second, we found grade-related increases of activity for subtraction, but not for multiplication, in a region of the right parietal cortex involved in the procedural manipulation of numerical quantities. The present results suggest that fluency in simple arithmetic in children may be achieved by both increasing reliance on verbal retrieval and by greater use of efficient quantity-based procedures, depending on the operation. PMID:25089323

  5. Automatic control design procedures for restructurable aircraft control

    NASA Technical Reports Server (NTRS)

    Looze, D. P.; Krolewski, S.; Weiss, J.; Barrett, N.; Eterno, J.

    1985-01-01

    A simple, reliable automatic redesign procedure for restructurable control is discussed. This procedure is based on Linear Quadratic (LQ) design methodologies. It employs a robust control system design for the unfailed aircraft to minimize the effects of failed surfaces and to extend the time available for restructuring the Flight Control System. The procedure uses the LQ design parameters for the unfailed system as a basis for choosing the design parameters of the failed system. This philosophy alloys the engineering trade-offs that were present in the nominal design to the inherited by the restructurable design. In particular, it alloys bandwidth limitations and performance trade-offs to be incorporated in the redesigned system. The procedure also has several other desirable features. It effectively redistributes authority among the available control effectors to maximize the system performance subject to actuator limitations and constraints. It provides a graceful performance degradation as the amount of control authority lessens. When given the parameters of the unfailed aircraft, the automatic redesign procedure reproduces the nominal control system design.

  6. Development and Validation of a Fast Procedure to Analyze Amoxicillin in River Waters by Direct-Injection LC-MS/MS

    ERIC Educational Resources Information Center

    Homem, Vera; Alves, Arminda; Santos, Lu´cia

    2014-01-01

    A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…

  7. A Simple Workstation for the Conservation of Library Materials.

    ERIC Educational Resources Information Center

    Conservation Correspondence, 1984

    1984-01-01

    The first step in designing a work station that is appropriate for both the maintenance and repair of library materials is to determine procedures likely to be necessary based on the nature of the collection and the type of use it receives. Necessary equipment includes a work station with a bench and storage space (an illustration and a list of…

  8. Using Modern Solid-State Analytical Tools for Investigations of an Advanced Carbon Capture Material: Experiments for the Inorganic Chemistry Laboratory

    ERIC Educational Resources Information Center

    Wriedt, Mario; Sculley, Julian P.; Aulakh, Darpandeep; Zhou, Hong-Cai

    2016-01-01

    A simple and straightforward synthesis of an ultrastable porous metal-organic framework (MOF) based on copper(II) and a mixed N donor ligand system is described as a laboratory experiment for chemistry undergraduate students. These experiments and the resulting analysis are designed to teach students basic research tools and procedures while…

  9. Bayesian model checking: A comparison of tests

    NASA Astrophysics Data System (ADS)

    Lucy, L. B.

    2018-06-01

    Two procedures for checking Bayesian models are compared using a simple test problem based on the local Hubble expansion. Over four orders of magnitude, p-values derived from a global goodness-of-fit criterion for posterior probability density functions agree closely with posterior predictive p-values. The former can therefore serve as an effective proxy for the difficult-to-calculate posterior predictive p-values.

  10. A simple and selective colorimetric mercury (II) sensing system based on chitosan stabilized gold nanoparticles and 2,6-pyridinedicarboxylic acid.

    PubMed

    Tian, Kun; Siegel, Gene; Tiwari, Ashutosh

    2017-02-01

    The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A comparison of methods for teaching receptive labeling to children with autism spectrum disorders.

    PubMed

    Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N

    2011-01-01

    Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed.

  12. Managing corneal foreign bodies in office-based general practice.

    PubMed

    Fraenkel, Alison; Lee, Lawrence R; Lee, Graham A

    2017-03-01

    Patients with a corneal foreign body may first present to their general practitioner (GP). Safe and efficacious management of these presentations avoids sight-threatening and eye-threatening complications. Removal of a simple, superficial foreign body without a slit lamp is within The Royal Australian College of General Practitioners' (RACGP's) curriculum and scope of practice. Knowing the rele-vant procedural skills and indications for referral is equally important. The objective of this article is to provide an evidence-based and expert-based guide to the management of corneal foreign bodies in the GP's office. History is key to identifying patient characteristics and mechanisms of ocular injury that are red flags for referral. Examination tech-niques and methods of superficial foreign body removal without a slit lamp are outlined, as well as the procedural threshold for referral to an ophthalmologist.

  13. Physics Based Modeling and Rendering of Vegetation in the Thermal Infrared

    NASA Technical Reports Server (NTRS)

    Smith, J. A.; Ballard, J. R., Jr.

    1999-01-01

    We outline a procedure for rendering physically-based thermal infrared images of simple vegetation scenes. Our approach incorporates the biophysical processes that affect the temperature distribution of the elements within a scene. Computer graphics plays a key role in two respects. First, in computing the distribution of scene shaded and sunlit facets and, second, in the final image rendering once the temperatures of all the elements in the scene have been computed. We illustrate our approach for a simple corn scene where the three-dimensional geometry is constructed based on measured morphological attributes of the row crop. Statistical methods are used to construct a representation of the scene in agreement with the measured characteristics. Our results are quite good. The rendered images exhibit realistic behavior in directional properties as a function of view and sun angle. The root-mean-square error in measured versus predicted brightness temperatures for the scene was 2.1 deg C.

  14. An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation

    PubMed Central

    Radhakrishnan, Nitin; Park, Jongwon; Kim, Chang-Soo

    2012-01-01

    Utilizing a simple fluidic structure, we demonstrate the improved performance of oxidase-based enzymatic biosensors. Electrolysis of water is utilized to generate bubbles to manipulate the oxygen microenvironment close to the biosensor in a fluidic channel. For the proper enzyme reactions to occur, a simple mechanical procedure of manipulating bubbles was developed to maximize the oxygen level while minimizing the pH change after electrolysis. The sensors show improved sensitivities based on the oxygen dependency of enzyme reaction. In addition, this oxygen-rich operation minimizes the ratio of electrochemical interference signal by ascorbic acid during sensor operation (i.e., amperometric detection of hydrogen peroxide). Although creatinine sensors have been used as the model system in this study, this method is applicable to many other biosensors that can use oxidase enzymes (e.g., glucose, alcohol, phenol, etc.) to implement a viable component for in-line fluidic sensor systems. PMID:23012527

  15. A remote sensing based vegetation classification logic for global land cover analysis

    USGS Publications Warehouse

    Running, Steven W.; Loveland, Thomas R.; Pierce, Lars L.; Nemani, R.R.; Hunt, E. Raymond

    1995-01-01

    This article proposes a simple new logic for classifying global vegetation. The critical features of this classification are that 1) it is based on simple, observable, unambiguous characteristics of vegetation structure that are important to ecosystem biogeochemistry and can be measured in the field for validation, 2) the structural characteristics are remotely sensible so that repeatable and efficient global reclassifications of existing vegetation will be possible, and 3) the defined vegetation classes directly translate into the biophysical parameters of interest by global climate and biogeochemical models. A first test of this logic for the continental United States is presented based on an existing 1 km AVHRR normalized difference vegetation index database. Procedures for solving critical remote sensing problems needed to implement the classification are discussed. Also, some inferences from this classification to advanced vegetation biophysical variables such as specific leaf area and photosynthetic capacity useful to global biogeochemical modeling are suggested.

  16. Use of Cdse/ZnS quantum dots for sensitive detection and quantification of paraquat in water samples.

    PubMed

    Durán, Gema M; Contento, Ana M; Ríos, Ángel

    2013-11-01

    Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L(-1). The lineal range was between 10-5×10(3) ng L(-1). RSD values in the range of 71-102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. "Supermarket Column Chromatography of Leaf Pigments" Revisited: Simple and Ecofriendly Separation of Plant Carotenoids, Chlorophylls, and Flavonoids from Green and Red Leaves

    ERIC Educational Resources Information Center

    Dias, Alice M.; Ferreira, Maria La Salete

    2015-01-01

    A simple and ecofriendly procedure was developed in order to prepare extracts from red and green leaves. This procedure enables the separation of yellow, green, and red band pigments and optimizes the previously reported baking soda "supermarket column". The same extract also led to a novel and colorful potato starch column, which can…

  18. Polynomial probability distribution estimation using the method of moments

    PubMed Central

    Mattsson, Lars; Rydén, Jesper

    2017-01-01

    We suggest a procedure for estimating Nth degree polynomial approximations to unknown (or known) probability density functions (PDFs) based on N statistical moments from each distribution. The procedure is based on the method of moments and is setup algorithmically to aid applicability and to ensure rigor in use. In order to show applicability, polynomial PDF approximations are obtained for the distribution families Normal, Log-Normal, Weibull as well as for a bimodal Weibull distribution and a data set of anonymized household electricity use. The results are compared with results for traditional PDF series expansion methods of Gram–Charlier type. It is concluded that this procedure is a comparatively simple procedure that could be used when traditional distribution families are not applicable or when polynomial expansions of probability distributions might be considered useful approximations. In particular this approach is practical for calculating convolutions of distributions, since such operations become integrals of polynomial expressions. Finally, in order to show an advanced applicability of the method, it is shown to be useful for approximating solutions to the Smoluchowski equation. PMID:28394949

  19. Polynomial probability distribution estimation using the method of moments.

    PubMed

    Munkhammar, Joakim; Mattsson, Lars; Rydén, Jesper

    2017-01-01

    We suggest a procedure for estimating Nth degree polynomial approximations to unknown (or known) probability density functions (PDFs) based on N statistical moments from each distribution. The procedure is based on the method of moments and is setup algorithmically to aid applicability and to ensure rigor in use. In order to show applicability, polynomial PDF approximations are obtained for the distribution families Normal, Log-Normal, Weibull as well as for a bimodal Weibull distribution and a data set of anonymized household electricity use. The results are compared with results for traditional PDF series expansion methods of Gram-Charlier type. It is concluded that this procedure is a comparatively simple procedure that could be used when traditional distribution families are not applicable or when polynomial expansions of probability distributions might be considered useful approximations. In particular this approach is practical for calculating convolutions of distributions, since such operations become integrals of polynomial expressions. Finally, in order to show an advanced applicability of the method, it is shown to be useful for approximating solutions to the Smoluchowski equation.

  20. A practical approach to estimate emission rates of indoor air pollutants due to the use of personal combustible products based on small-chamber studies.

    PubMed

    Szulejko, Jan E; Kim, Ki-Hyun

    2016-02-01

    As emission rates of airborne pollutants are commonly measured from combusting substances placed inside small chambers, those values need to be re-evaluated for the possible significance under practical conditions. Here, a simple numerical procedure is investigated to extrapolate the chamber-based emission rates of formaldehyde that can be released from various combustible sources including e-cigarettes, conventional cigarettes, or scented candles to their concentration levels in a small room with relatively poor ventilation. This simple procedure relies on a mass balance approach by considering the masses of pollutants emitted from source and lost through ventilation under the assumption that mixing occurs instantaneously in the room without chemical reactions or surface sorption. The results of our study provide valuable insights into re-evaluation procedure of chamber data to allow comparison between extrapolated and recommended values to judge the safe use of various combustible products in confined spaces. If two scented candles with a formaldehyde emission rate of 310 µg h(-1) each were lit for 4 h in a small 20 m(3) room with an air change rate of 0.5 h(-1), then the 4-h (candle lit) and 8-h (up to 8 h after candle lighting) TWA [FA] were determined to be 28.5 and 23.5 ppb, respectively. This is clearly above the 8-h NIOSH recommended exposure limit (REL) time weighted average of 16 ppb. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. A common base method for analysis of qPCR data and the application of simple blocking in qPCR experiments.

    PubMed

    Ganger, Michael T; Dietz, Geoffrey D; Ewing, Sarah J

    2017-12-01

    qPCR has established itself as the technique of choice for the quantification of gene expression. Procedures for conducting qPCR have received significant attention; however, more rigorous approaches to the statistical analysis of qPCR data are needed. Here we develop a mathematical model, termed the Common Base Method, for analysis of qPCR data based on threshold cycle values (C q ) and efficiencies of reactions (E). The Common Base Method keeps all calculations in the logscale as long as possible by working with log 10 (E) ∙ C q , which we call the efficiency-weighted C q value; subsequent statistical analyses are then applied in the logscale. We show how efficiency-weighted C q values may be analyzed using a simple paired or unpaired experimental design and develop blocking methods to help reduce unexplained variation. The Common Base Method has several advantages. It allows for the incorporation of well-specific efficiencies and multiple reference genes. The method does not necessitate the pairing of samples that must be performed using traditional analysis methods in order to calculate relative expression ratios. Our method is also simple enough to be implemented in any spreadsheet or statistical software without additional scripts or proprietary components.

  2. Improved pressure-velocity coupling algorithm based on minimization of global residual norm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatwani, A.U.; Turan, A.

    1991-01-01

    In this paper an improved pressure velocity coupling algorithm is proposed based on the minimization of the global residual norm. The procedure is applied to SIMPLE and SIMPLEC algorithms to automatically select the pressure underrelaxation factor to minimize the global residual norm at each iteration level. Test computations for three-dimensional turbulent, isothermal flow is a toroidal vortex combustor indicate that velocity underrelaxation factors as high as 0.7 can be used to obtain a converged solution in 300 iterations.

  3. 5 CFR 9701.521 - Grievance procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... paragraphs (d), (f), and (g) of this section, the procedures must be the exclusive administrative procedures... simple, provide for expeditious processing, and include procedures that— (i) Assure an exclusive representative the right, in its own behalf or on behalf of any employee in the unit represented by the exclusive...

  4. Practicing Surgeons Lead in Quality Care, Safety, and Cost Control

    PubMed Central

    Shively, Eugene H.; Heine, Michael J.; Schell, Robert H.; Sharpe, J Neal; Garrison, R Neal; Vallance, Steven R.; DeSimone, Kenneth J.S.; Polk, Hiram C.

    2004-01-01

    Objective: To report the experiences of 66 surgical specialists from 15 different hospitals who performed 43 CPT-based procedures more than 16,000 times. Summary Background Data: Surgeons are under increasing pressure to demonstrate patient safety data as quantitated by objective and subjective outcomes that meet or exceed the standards of benchmark institutions or databases. Methods: Data from 66 surgical specialists on 43 CPT-based procedures were accessioned over a 4-year period. The hospitals vary from a small 30-bed hospital to large teaching hospitals. All reported deaths and complications were verified from hospital and office records and compared with benchmarks. Results: Over a 4-year inclusive period (1999–2002), 16,028 elective operations were accessioned. There was a total 1.4% complication rate and 0.05% death rate. A system has been developed for tracking outcomes. A wide range of improvements have been identified. These include the following: 1) improved classification of indications for systemic prophylactic antibiotic use and reduction in the variety of drugs used, 2) shortened length of stay for standard procedures in different surgical specialties, 3) adherence to strict indicators for selected operative procedures, 4) less use of costly diagnostic procedures, 5) decreased use of expensive home health services, 6) decreased use of very expensive drugs, 7) identification of the unnecessary expense of disposable laparoscopic devices, 8) development of a method to compare a one-surgeon hospital with his peers, and 9) development of unique protocols for interaction of anesthesia and surgery. The system also provides a very good basis for confirmation of patient safety and improvement therein. Conclusions: Since 1998, Quality Surgical Solutions, PLLC, has developed simple physician-authored protocols for delivering high-quality and cost-effective surgery that measure up to benchmark institutions. We have discovered wide areas for improvements in surgery by adherence to simple protocols, minimizing death and complications and clarifying cost issues. PMID:15166954

  5. Taboo Search: An Approach to the Multiple Minima Problem

    NASA Astrophysics Data System (ADS)

    Cvijovic, Djurdje; Klinowski, Jacek

    1995-02-01

    Described here is a method, based on Glover's taboo search for discrete functions, of solving the multiple minima problem for continuous functions. As demonstrated by model calculations, the algorithm avoids entrapment in local minima and continues the search to give a near-optimal final solution. Unlike other methods of global optimization, this procedure is generally applicable, easy to implement, derivative-free, and conceptually simple.

  6. Tuning of PID controllers for boiler-turbine units.

    PubMed

    Tan, Wen; Liu, Jizhen; Fang, Fang; Chen, Yanqiao

    2004-10-01

    A simple two-by-two model for a boiler-turbine unit is demonstrated in this paper. The model can capture the essential dynamics of a unit. The design of a coordinated controller is discussed based on this model. A PID control structure is derived, and a tuning procedure is proposed. The examples show that the method is easy to apply and can achieve acceptable performance.

  7. Early Detection of Breast Cancer Using Molecular Beacons

    DTIC Science & Technology

    2008-01-01

    a molecular beacon (MB)-based approach for direct examination of gene expression in viable and fixed cells (2, 3). This objective of proposed study ...can be distinguished from normal cells (dark) (Figure 1) (2, 3, 8). Recently, a class of new fluorescent emitting nanoparticles, semiconductor ...morphological classification. This method may offer a simple and fast procedure to detect biomarker gene expression in clinical samples. Our study results

  8. A new algorithm to handle finite nuclear mass effects in electronic calculations: the ISOTOPE program.

    PubMed

    Gonçalves, Cristina P; Mohallem, José R

    2004-11-15

    We report the development of a simple algorithm to modify quantum chemistry codes based on the LCAO procedure, to account for the isotope problem in electronic structure calculations. No extra computations are required compared to standard Born-Oppenheimer calculations. An upgrade of the Gamess package called ISOTOPE is presented, and its applicability is demonstrated in some examples.

  9. Determination of stress intensity factors for interface cracks under mixed-mode loading

    NASA Technical Reports Server (NTRS)

    Naik, Rajiv A.; Crews, John H., Jr.

    1992-01-01

    A simple technique was developed using conventional finite element analysis to determine stress intensity factors, K1 and K2, for interface cracks under mixed-mode loading. This technique involves the calculation of crack tip stresses using non-singular finite elements. These stresses are then combined and used in a linear regression procedure to calculate K1 and K2. The technique was demonstrated by calculating three different bimaterial combinations. For the normal loading case, the K's were within 2.6 percent of an exact solution. The normalized K's under shear loading were shown to be related to the normalized K's under normal loading. Based on these relations, a simple equation was derived for calculating K1 and K2 for mixed-mode loading from knowledge of the K's under normal loading. The equation was verified by computing the K's for a mixed-mode case with equal and normal shear loading. The correlation between exact and finite element solutions is within 3.7 percent. This study provides a simple procedure to compute K2/K1 ratio which has been used to characterize the stress state at the crack tip for various combinations of materials and loadings. Tests conducted over a range of K2/K1 ratios could be used to fully characterize interface fracture toughness.

  10. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  11. A seismic optimization procedure for reinforced concrete framed buildings based on eigenfrequency optimization

    NASA Astrophysics Data System (ADS)

    Arroyo, Orlando; Gutiérrez, Sergio

    2017-07-01

    Several seismic optimization methods have been proposed to improve the performance of reinforced concrete framed (RCF) buildings; however, they have not been widely adopted among practising engineers because they require complex nonlinear models and are computationally expensive. This article presents a procedure to improve the seismic performance of RCF buildings based on eigenfrequency optimization, which is effective, simple to implement and efficient. The method is used to optimize a 10-storey regular building, and its effectiveness is demonstrated by nonlinear time history analyses, which show important reductions in storey drifts and lateral displacements compared to a non-optimized building. A second example for an irregular six-storey building demonstrates that the method provides benefits to a wide range of RCF structures and supports the applicability of the proposed method.

  12. An assessment of the adaptive unstructured tetrahedral grid, Euler Flow Solver Code FELISA

    NASA Technical Reports Server (NTRS)

    Djomehri, M. Jahed; Erickson, Larry L.

    1994-01-01

    A three-dimensional solution-adaptive Euler flow solver for unstructured tetrahedral meshes is assessed, and the accuracy and efficiency of the method for predicting sonic boom pressure signatures about simple generic models are demonstrated. Comparison of computational and wind tunnel data and enhancement of numerical solutions by means of grid adaptivity are discussed. The mesh generation is based on the advancing front technique. The FELISA code consists of two solvers, the Taylor-Galerkin and the Runge-Kutta-Galerkin schemes, both of which are spacially discretized by the usual Galerkin weighted residual finite-element methods but with different explicit time-marching schemes to steady state. The solution-adaptive grid procedure is based on either remeshing or mesh refinement techniques. An alternative geometry adaptive procedure is also incorporated.

  13. A Derived Transfer of Simple Discrimination and Self-Reported Arousal Functions in Spider Fearful and Non-Spider-Fearful Participants

    ERIC Educational Resources Information Center

    Smyth, Sinead; Barnes-Holmes, Dermot; Forsyth, John P.

    2006-01-01

    Two experiments investigated the derived transfer of functions through equivalence relations established using a stimulus pairing observation procedure. In Experiment 1, participants were trained on a simple discrimination (A1+/A2-) and then a stimulus pairing observation procedure was used to establish 4 stimulus pairings (A1-B1, A2-B2, B1-C1,…

  14. Analysis of Slug Tests in Formations of High Hydraulic Conductivity

    USGS Publications Warehouse

    Butler, J.J.; Garnett, E.J.; Healey, J.M.

    2003-01-01

    A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

  15. Analysis of slug tests in formations of high hydraulic conductivity.

    PubMed

    Butler, James J; Garnett, Elizabeth J; Healey, John M

    2003-01-01

    A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

  16. A simple method to determine evaporation and compensate for liquid losses in small-scale cell culture systems.

    PubMed

    Wiegmann, Vincent; Martinez, Cristina Bernal; Baganz, Frank

    2018-04-24

    Establish a method to indirectly measure evaporation in microwell-based cell culture systems and show that the proposed method allows compensating for liquid losses in fed-batch processes. A correlation between evaporation and the concentration of Na + was found (R 2  = 0.95) when using the 24-well-based miniature bioreactor system (micro-Matrix) for a batch culture with GS-CHO. Based on these results, a method was developed to counteract evaporation with periodic water additions based on measurements of the Na + concentration. Implementation of this method resulted in a reduction of the relative liquid loss after 15 days of a fed-batch cultivation from 36.7 ± 6.7% without volume corrections to 6.9 ± 6.5% with volume corrections. A procedure was established to indirectly measure evaporation through a correlation with the level of Na + ions in solution and deriving a simple formula to account for liquid losses.

  17. Characterization and Amplification of Gene-Based Simple Sequence Repeat (SSR) Markers in Date Palm.

    PubMed

    Zhao, Yongli; Keremane, Manjunath; Prakash, Channapatna S; He, Guohao

    2017-01-01

    The paucity of molecular markers limits the application of genetic and genomic research in date palm (Phoenix dactylifera L.). Availability of expressed sequence tag (EST) sequences in date palm may provide a good resource for developing gene-based markers. This study characterizes a substantial fraction of transcriptome sequences containing simple sequence repeats (SSRs) from the EST sequences in date palm. The EST sequences studied are mainly homologous to those of Elaeis guineensis and Musa acuminata. A total of 911 gene-based SSR markers, characterized with functional annotations, have provided a useful basis not only for discovering candidate genes and understanding genetic basis of traits of interest but also for developing genetic and genomic tools for molecular research in date palm, such as diversity study, quantitative trait locus (QTL) mapping, and molecular breeding. The procedures of DNA extraction, polymerase chain reaction (PCR) amplification of these gene-based SSR markers, and gel electrophoresis of PCR products are described in this chapter.

  18. Western blotting.

    PubMed

    Kurien, Biji T; Scofield, R Hal

    2006-04-01

    Western blotting (protein blotting or immunoblotting) is a powerful and important procedure for the immunodetection of proteins post-electrophoresis, particularly proteins that are of low abundance. Since the inception of the protocol for protein transfer from an electrophoresed gel to a membrane in 1979, protein blotting has evolved greatly. The scientific community is now confronted with a variety of ways and means to carry out this transfer. This review describes the various procedures that have been used to transfer proteins from a gel to a membrane based on the principles of simple diffusion, vacuum-assisted solvent flow and electrophoretic elution. Finally, a brief description of methods generally used to detect antigens on blots is also described.

  19. A new statistical method for transfer coefficient calculations in the framework of the general multiple-compartment model of transport for radionuclides in biological systems.

    PubMed

    Garcia, F; Arruda-Neto, J D; Manso, M V; Helene, O M; Vanin, V R; Rodriguez, O; Mesa, J; Likhachev, V P; Filho, J W; Deppman, A; Perez, G; Guzman, F; de Camargo, S P

    1999-10-01

    A new and simple statistical procedure (STATFLUX) for the calculation of transfer coefficients of radionuclide transport to animals and plants is proposed. The method is based on the general multiple-compartment model, which uses a system of linear equations involving geometrical volume considerations. By using experimentally available curves of radionuclide concentrations versus time, for each animal compartment (organs), flow parameters were estimated by employing a least-squares procedure, whose consistency is tested. Some numerical results are presented in order to compare the STATFLUX transfer coefficients with those from other works and experimental data.

  20. Reconstruction of palatal defect using mucoperiosteal hinge flap and pushback palatoplasty.

    PubMed

    Lee, S I; Lee, H S; Hwang, K

    2001-11-01

    This article describes a simple, new surgical technique to provide a complete two-layer closure of palatal defect resulting from a surgical complication of trans palatal resection of skull base chordoma. The nasal layer was reconstructed with triangular shape oral mucoperiosteal turn over hinge flap based on anterior margin of palatal defect and rectangular shaped lateral nasal mucosal hinge flaps. The oral layer was reconstructed with conventional pushback V-Y advancement 2-flaps palatoplasty. Each layer of the flaps were secured with two key mattress suture for flap coaptation. This technique has some advantages: simple, short operation time, one-stage procedure, no need of osteotomy. It can close small- to medium-sized palatal defect of palate or wide cleft palate and can prevent common complication of oronasal fistula, which could be caused by tension.

  1. Smith predictor based-sliding mode controller for integrating processes with elevated deadtime.

    PubMed

    Camacho, Oscar; De la Cruz, Francisco

    2004-04-01

    An approach to control integrating processes with elevated deadtime using a Smith predictor sliding mode controller is presented. A PID sliding surface and an integrating first-order plus deadtime model have been used to synthesize the controller. Since the performance of existing controllers with a Smith predictor decrease in the presence of modeling errors, this paper presents a simple approach to combining the Smith predictor with the sliding mode concept, which is a proven, simple, and robust procedure. The proposed scheme has a set of tuning equations as a function of the characteristic parameters of the model. For implementation of our proposed approach, computer based industrial controllers that execute PID algorithms can be used. The performance and robustness of the proposed controller are compared with the Matausek-Micić scheme for linear systems using simulations.

  2. Teaching a Generalizable Language Strategy.

    ERIC Educational Resources Information Center

    Foxx, R. M.; And Others

    This paper describes the development and use of language training procedures, referred to as cues-pause-point procedures, that rely on behavioral principles and simple and natural teaching procedures and that are exhibited in many normal parent-child or teacher-student verbal interactions. The procedures have been effective in teaching severely…

  3. CCD image sensor induced error in PIV applications

    NASA Astrophysics Data System (ADS)

    Legrand, M.; Nogueira, J.; Vargas, A. A.; Ventas, R.; Rodríguez-Hidalgo, M. C.

    2014-06-01

    The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (˜0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.

  4. Alkaline Comet Assay for Assessing DNA Damage in Individual Cells.

    PubMed

    Pu, Xinzhu; Wang, Zemin; Klaunig, James E

    2015-08-06

    Single-cell gel electrophoresis, commonly called a comet assay, is a simple and sensitive method for assessing DNA damage at the single-cell level. It is an important technique in genetic toxicological studies. The comet assay performed under alkaline conditions (pH >13) is considered the optimal version for identifying agents with genotoxic activity. The alkaline comet assay is capable of detecting DNA double-strand breaks, single-strand breaks, alkali-labile sites, DNA-DNA/DNA-protein cross-linking, and incomplete excision repair sites. The inclusion of digestion of lesion-specific DNA repair enzymes in the procedure allows the detection of various DNA base alterations, such as oxidative base damage. This unit describes alkaline comet assay procedures for assessing DNA strand breaks and oxidative base alterations. These methods can be applied in a variety of cells from in vitro and in vivo experiments, as well as human studies. Copyright © 2015 John Wiley & Sons, Inc.

  5. Spectral analysis based on fast Fourier transformation (FFT) of surveillance data: the case of scarlet fever in China.

    PubMed

    Zhang, T; Yang, M; Xiao, X; Feng, Z; Li, C; Zhou, Z; Ren, Q; Li, X

    2014-03-01

    Many infectious diseases exhibit repetitive or regular behaviour over time. Time-domain approaches, such as the seasonal autoregressive integrated moving average model, are often utilized to examine the cyclical behaviour of such diseases. The limitations for time-domain approaches include over-differencing and over-fitting; furthermore, the use of these approaches is inappropriate when the assumption of linearity may not hold. In this study, we implemented a simple and efficient procedure based on the fast Fourier transformation (FFT) approach to evaluate the epidemic dynamic of scarlet fever incidence (2004-2010) in China. This method demonstrated good internal and external validities and overcame some shortcomings of time-domain approaches. The procedure also elucidated the cycling behaviour in terms of environmental factors. We concluded that, under appropriate circumstances of data structure, spectral analysis based on the FFT approach may be applicable for the study of oscillating diseases.

  6. Improvements in soft gelatin capsule sample preparation for USP-based simethicone FTIR analysis.

    PubMed

    Hargis, Amy D; Whittall, Linda B

    2013-02-23

    Due to the absence of a significant chromophore, Simethicone raw material and finished product analysis is achieved using a FTIR-based method that quantifies the polydimethylsiloxane (PDMS) component of the active ingredient. The method can be found in the USP monographs for several dosage forms of Simethicone-containing pharmaceutical products. For soft gelatin capsules, the PDMS assay values determined using the procedure described in the USP method were variable (%RSDs from 2 to 9%) and often lower than expected based on raw material values. After investigation, it was determined that the extraction procedure used for sample preparation was causing loss of material to the container walls due to the hydrophobic nature of PDMS. Evaluation revealed that a simple dissolution of the gelatin capsule fill in toluene provided improved assay results (%RSDs≤0.5%) as well as a simplified and rapid sample preparation. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. A GIS-based automated procedure for landslide susceptibility mapping by the Conditional Analysis method: the Baganza valley case study (Italian Northern Apennines)

    NASA Astrophysics Data System (ADS)

    Clerici, Aldo; Perego, Susanna; Tellini, Claudio; Vescovi, Paolo

    2006-08-01

    Among the many GIS based multivariate statistical methods for landslide susceptibility zonation, the so called “Conditional Analysis method” holds a special place for its conceptual simplicity. In fact, in this method landslide susceptibility is simply expressed as landslide density in correspondence with different combinations of instability-factor classes. To overcome the operational complexity connected to the long, tedious and error prone sequence of commands required by the procedure, a shell script mainly based on the GRASS GIS was created. The script, starting from a landslide inventory map and a number of factor maps, automatically carries out the whole procedure resulting in the construction of a map with five landslide susceptibility classes. A validation procedure allows to assess the reliability of the resulting model, while the simple mean deviation of the density values in the factor class combinations, helps to evaluate the goodness of landslide density distribution. The procedure was applied to a relatively small basin (167 km2) in the Italian Northern Apennines considering three landslide types, namely rotational slides, flows and complex landslides, for a total of 1,137 landslides, and five factors, namely lithology, slope angle and aspect, elevation and slope/bedding relations. The analysis of the resulting 31 different models obtained combining the five factors, confirms the role of lithology, slope angle and slope/bedding relations in influencing slope stability.

  8. A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.

    EPA Science Inventory

    John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192).

    We have developed a simple, mild extraction procedure using methanol which, when...

  9. A COMPARISON OF METHODS FOR TEACHING RECEPTIVE LABELING TO CHILDREN WITH AUTISM SPECTRUM DISORDERS

    PubMed Central

    Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N

    2011-01-01

    Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed. PMID:21941380

  10. Analysis of aircraft longitudinal handling qualities

    NASA Technical Reports Server (NTRS)

    Hess, R. A.

    1981-01-01

    The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion for determining the susceptibility of an aircraft to pilot induced oscillations (PIO) is formulated. Finally, a model-based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.

  11. Prediction of aircraft handling qualities using analytical models of the human pilot

    NASA Technical Reports Server (NTRS)

    Hess, R. A.

    1982-01-01

    The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion for determining the susceptibility of an aircraft to pilot-induced oscillations (PIO) is formulated. Finally, a model-based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.

  12. Prediction of aircraft handling qualities using analytical models of the human pilot

    NASA Technical Reports Server (NTRS)

    Hess, R. A.

    1982-01-01

    The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion for determining the susceptibility of an aircraft to pilot induced oscillations is formulated. Finally, a model based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.

  13. Comments on the variational modified-hypernetted-chain theory for simple fluids

    NASA Astrophysics Data System (ADS)

    Rosenfeld, Yaakov

    1986-02-01

    The variational modified-hypernetted-chain (VMHNC) theory, based on the approximation of universality of the bridge functions, is reformulated. The new formulation includes recent calculations by Lado and by Lado, Foiles, and Ashcroft, as two stages in a systematic approach which is analyzed. A variational iterative procedure for solving the exact (diagrammatic) equations for the fluid structure which is formally identical to the VMHNC is described, featuring the theory of simple classical fluids as a one-iteration theory. An accurate method for calculating the pair structure for a given potential and for inverting structure factor data in order to obtain the potential and the thermodynamic functions, follows from our analysis.

  14. An analytical approach for predicting pilot induced oscillations

    NASA Technical Reports Server (NTRS)

    Hess, R. A.

    1981-01-01

    The optimal control model (OCM) of the human pilot is applied to the study of aircraft handling qualities. Attention is focused primarily on longitudinal tasks. The modeling technique differs from previous applications of the OCM in that considerable effort is expended in simplifying the pilot/vehicle analysis. After briefly reviewing the OCM, a technique for modeling the pilot controlling higher order systems is introduced. Following this, a simple criterion or determining the susceptability of an aircraft to pilot induced oscillations (PIO) is formulated. Finally, a model-based metric for pilot rating prediction is discussed. The resulting modeling procedure provides a relatively simple, yet unified approach to the study of a variety of handling qualities problems.

  15. Validation of the replica trick for simple models

    NASA Astrophysics Data System (ADS)

    Shinzato, Takashi

    2018-04-01

    We discuss the replica analytic continuation using several simple models in order to prove mathematically the validity of the replica analysis, which is used in a wide range of fields related to large-scale complex systems. While replica analysis consists of two analytical techniques—the replica trick (or replica analytic continuation) and the thermodynamical limit (and/or order parameter expansion)—we focus our study on replica analytic continuation, which is the mathematical basis of the replica trick. We apply replica analysis to solve a variety of analytical models, and examine the properties of replica analytic continuation. Based on the positive results for these models we propose that replica analytic continuation is a robust procedure in replica analysis.

  16. A simple control for sediment-toxicity exposures using the amphipod, Hyalella azteca

    USGS Publications Warehouse

    Lasier, Peter J.; Urich, Matthew L.

    2014-01-01

    Sediment-toxicity exposures comparing survival and growth of the freshwater amphipod, Hyalella azteca, are often components of aquatic-habitat assessments. Standardized exposure methods have been established and require evaluations for quality assurance. Test acceptability using performance-based criteria can be determined from exposures to control sediments, which are collected from the environment or formulated from commercially available components. Amending sand with leached alfalfa solids provided a simple formulated sediment that elicited consistently acceptable survival and growth in 28-day exposures with and without a daily feeding regime. A procedure is described for preparing the sediment along with results from comparisons among sand, amended sand, and field-collected sediments that incorporated three feeding regimes.

  17. Test Equality between Three Treatments under an Incomplete Block Crossover Design.

    PubMed

    Lui, Kung-Jong

    2015-01-01

    Under a random effects linear additive risk model, we compare two experimental treatments with a placebo in continuous data under an incomplete block crossover trial. We develop three test procedures for simultaneously testing equality between two experimental treatments and a placebo, as well as interval estimators for the mean difference between treatments. We apply Monte Carlo simulations to evaluate the performance of these test procedures and interval estimators in a variety of situations. We note that the bivariate test procedure accounting for the dependence structure based on the F-test is preferable to the other two procedures when there is only one of the two experimental treatments has a non-zero effect vs. the placebo. We note further that when the effects of the two experimental treatments vs. a placebo are in the same relative directions and are approximately of equal magnitude, the summary test procedure based on a simple average of two weighted-least-squares (WLS) estimators can outperform the other two procedures with respect to power. When one of the two experimental treatments has a relatively large effect vs. the placebo, the univariate test procedure with using Bonferroni's equality can be still of use. Finally, we use the data about the forced expiratory volume in 1 s (FEV1) readings taken from a double-blind crossover trial comparing two different doses of formoterol with a placebo to illustrate the use of test procedures and interval estimators proposed here.

  18. A simple method for measuring porcine circovirus 2 whole virion particles and standardizing vaccine formulation.

    PubMed

    Zanotti, Cinzia; Amadori, Massimo

    2015-03-01

    Porcine Circovirus 2 (PCV2) is involved in porcine circovirus-associated disease, that causes great economic losses to the livestock industry worldwide. Vaccination against PCV2 proved to be very effective in reducing disease occurrence and it is currently performed on a large scale. Starting from a previous model concerning Foot-and Mouth Disease Virus antigens, we developed a rapid and simple method to quantify PCV2 whole virion particles in inactivated vaccines. This procedure, based on sucrose gradient analysis and fluorometric evaluation of viral genomic content, allows for a better standardization of the antigen payload in vaccine batches. It also provides a valid indication of virion integrity. Most important, such a method can be applied to whole virion vaccines regardless of the production procedures, thus enabling meaningful comparisons on a common basis. In a future batch consistency approach to PCV2 vaccine manufacture, our procedure represents a valuable tool to improve in-process controls and to guarantee conformity of the final product with passmarks for approval. This might have important repercussions in terms of reduced usage of animals for vaccine batch release, in the framework of the current 3Rs policy. Copyright © 2015 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  19. A simple Lagrangian forecast system with aviation forecast potential

    NASA Technical Reports Server (NTRS)

    Petersen, R. A.; Homan, J. H.

    1983-01-01

    A trajectory forecast procedure is developed which uses geopotential tendency fields obtained from a simple, multiple layer, potential vorticity conservative isentropic model. This model can objectively account for short-term advective changes in the mass field when combined with fine-scale initial analyses. This procedure for producing short-term, upper-tropospheric trajectory forecasts employs a combination of a detailed objective analysis technique, an efficient mass advection model, and a diagnostically proven trajectory algorithm, none of which require extensive computer resources. Results of initial tests are presented, which indicate an exceptionally good agreement for trajectory paths entering the jet stream and passing through an intensifying trough. It is concluded that this technique not only has potential for aiding in route determination, fuel use estimation, and clear air turbulence detection, but also provides an example of the types of short range forecasting procedures which can be applied at local forecast centers using simple algorithms and a minimum of computer resources.

  20. NGA-West 2 GMPE average site coefficients for use in earthquake-resistant design

    USGS Publications Warehouse

    Borcherdt, Roger D.

    2015-01-01

    Site coefficients corresponding to those in tables 11.4–1 and 11.4–2 of Minimum Design Loads for Buildings and Other Structures published by the American Society of Civil Engineers (Standard ASCE/SEI 7-10) are derived from four of the Next Generation Attenuation West2 (NGA-W2) Ground-Motion Prediction Equations (GMPEs). The resulting coefficients are compared with those derived by other researchers and those derived from the NGA-West1 database. The derivation of the NGA-W2 average site coefficients provides a simple procedure to update site coefficients with each update in the Maximum Considered Earthquake Response MCER maps. The simple procedure yields average site coefficients consistent with those derived for site-specific design purposes. The NGA-W2 GMPEs provide simple scale factors to reduce conservatism in current simplified design procedures.

  1. Optimized in vitro procedure for assessing the cytocompatibility of magnesium-based biomaterials.

    PubMed

    Jung, Ole; Smeets, Ralf; Porchetta, Dario; Kopp, Alexander; Ptock, Christoph; Müller, Ute; Heiland, Max; Schwade, Max; Behr, Björn; Kröger, Nadja; Kluwe, Lan; Hanken, Henning; Hartjen, Philip

    2015-09-01

    Magnesium (Mg) is a promising biomaterial for degradable implant applications that has been extensively studied in vitro and in vivo in recent years. In this study, we developed a procedure that allows an optimized and uniform in vitro assessment of the cytocompatibility of Mg-based materials while respecting the standard protocol DIN EN ISO 10993-5:2009. The mouse fibroblast line L-929 was chosen as the preferred assay cell line and MEM supplemented with 10% FCS, penicillin/streptomycin and 4mM l-glutamine as the favored assay medium. The procedure consists of (1) an indirect assessment of effects of soluble Mg corrosion products in material extracts and (2) a direct assessment of the surface compatibility in terms of cell attachment and cytotoxicity originating from active corrosion processes. The indirect assessment allows the quantification of cell-proliferation (BrdU-assay), viability (XTT-assay) as well as cytotoxicity (LDH-assay) of the mouse fibroblasts incubated with material extracts. Direct assessment visualizes cells attached to the test materials by means of live-dead staining. The colorimetric assays and the visual evaluation complement each other and the combination of both provides an optimized and simple procedure for assessing the cytocompatibility of Mg-based biomaterials in vitro. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. Correlates of Harmful Alcohol Consumption in Six Countries: Development of an International Screening and Assessment Procedure.

    ERIC Educational Resources Information Center

    Aasland, Olaf Gjerlow; and Others

    The aim of this study was to develop tools for screening and assessment of socio-medical effects of alcohol use which are simple and inexpensive enough to be used in any primary health care setting. A test protocol was prepared by a group of investigators from Australia, Bulgaria, Kenya, Mexico, Norway, and the United States. Based on a number of…

  3. Topics in Statistical Calibration

    DTIC Science & Technology

    2014-03-27

    on a parametric bootstrap where, instead of sampling directly from the residuals , samples are drawn from a normal distribution. This procedure will...addition to centering them (Davison and Hinkley, 1997). When there are outliers in the residuals , the bootstrap distribution of x̂0 can become skewed or...based and inversion methods using the linear mixed-effects model. Then, a simple parametric bootstrap algorithm is proposed that can be used to either

  4. Determination of Pesticides Residues in Cucumbers Grown in Greenhouse and the Effect of Some Procedures on Their Residues.

    PubMed

    Leili, Mostafa; Pirmoghani, Amin; Samadi, Mohammad Taghi; Shokoohi, Reza; Roshanaei, Ghodratollah; Poormohammadi, Ali

    2016-11-01

    The objective of this study was to determine the residual concentrations of ethion and imidacloprid in cucumbers grown in greenhouse. The effect of some simple processing procedures on both ethion and imidacloprid residues were also studied. Ten active greenhouses that produce cucumber were randomly selected. Ethion and imidacloprid as the most widely used pesticides were measured in cucumber samples of studied greenhouses. Moreover, the effect of storing, washing, and peeling as simple processing procedures on both ethion and imidacloprid residues were investigated. One hour after pesticide application; the maximum residue levels (MRLs) of ethion and imidacloprid were higher than that of Codex standard level. One day after pesticide application, the levels of pesticides were decreased about 35 and 31% for ethion and imidacloprid, respectively, which still were higher than the MRL. Washing procedure led to about 51 and 42.5% loss in ethion and imidacloprid residues, respectively. Peeling procedure also led to highest loss of 93.4 and 63.7% in ethion and imidacloprid residues, respectively. The recovery for both target analytes was in the range between 88 and 102%. The residue values in collected samples one hour after pesticides application were higher than standard value. The storing, washing, and peeling procedures lead to the decrease of pesticide residues in greenhouse cucumbers. Among them, the peeling procedure has the greatest impact on residual reduction. Therefore, these procedures can be used as simple and effective processing techniques for reducing and removing pesticides from greenhouse products before their consumption.

  5. A simple structure wavelet transform circuit employing function link neural networks and SI filters

    NASA Astrophysics Data System (ADS)

    Mu, Li; Yigang, He

    2016-12-01

    Signal processing by means of analog circuits offers advantages from a power consumption viewpoint. Implementing wavelet transform (WT) using analog circuits is of great interest when low-power consumption becomes an important issue. In this article, a novel simple structure WT circuit in analog domain is presented by employing functional link neural network (FLNN) and switched-current (SI) filters. First, the wavelet base is approximated using FLNN algorithms for giving a filter transfer function that is suitable for simple structure WT circuit implementation. Next, the WT circuit is constructed with the wavelet filter bank, whose impulse response is the approximated wavelet and its dilations. The filter design that follows is based on a follow-the-leader feedback (FLF) structure with multiple output bilinear SI integrators and current mirrors as the main building blocks. SI filter is well suited for this application since the dilation constant across different scales of the transform can be precisely implemented and controlled by the clock frequency of the circuit with the same system architecture. Finally, to illustrate the design procedure, a seventh-order FLNN-approximated Gaussian wavelet is implemented as an example. Simulations have successfully verified that the designed simple structure WT circuit has low sensitivity, low-power consumption and litter effect to the imperfections.

  6. Photo-Modeling and Cloud Computing. Applications in the Survey of Late Gothic Architectural Elements

    NASA Astrophysics Data System (ADS)

    Casu, P.; Pisu, C.

    2013-02-01

    This work proposes the application of the latest methods of photo-modeling to the study of Gothic architecture in Sardinia. The aim is to consider the versatility and ease of use of such documentation tools in order to study architecture and its ornamental details. The paper illustrates a procedure of integrated survey and restitution, with the purpose to obtain an accurate 3D model of some gothic portals. We combined the contact survey and the photographic survey oriented to the photo-modelling. The software used is 123D Catch by Autodesk an Image Based Modelling (IBM) system available free. It is a web-based application that requires a few simple steps to produce a mesh from a set of not oriented photos. We tested the application on four portals, working at different scale of detail: at first the whole portal and then the different architectural elements that composed it. We were able to model all the elements and to quickly extrapolate simple sections, in order to make a comparison between the moldings, highlighting similarities and differences. Working in different sites at different scale of detail, have allowed us to test the procedure under different conditions of exposure, sunshine, accessibility, degradation of surface, type of material, and with different equipment and operators, showing if the final result could be affected by these factors. We tested a procedure, articulated in a few repeatable steps, that can be applied, with the right corrections and adaptations, to similar cases and/or larger or smaller elements.

  7. Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera.

    PubMed

    Reyes, Bersain A; Reljin, Natasa; Kong, Youngsun; Nam, Yunyoung; Ha, Sangho; Chon, Ki H

    2016-03-18

    A smartphone-based tidal volume (V(T)) estimator was recently introduced by our research group, where an Android application provides a chest movement signal whose peak-to-peak amplitude is highly correlated with reference V(T) measured by a spirometer. We found a Normalized Root Mean Squared Error (NRMSE) of 14.998% ± 5.171% (mean ± SD) when the smartphone measures were calibrated using spirometer data. However, the availability of a spirometer device for calibration is not realistic outside clinical or research environments. In order to be used by the general population on a daily basis, a simple calibration procedure not relying on specialized devices is required. In this study, we propose taking advantage of the linear correlation between smartphone measurements and V(T) to obtain a calibration model using information computed while the subject breathes through a commercially-available incentive spirometer (IS). Experiments were performed on twelve (N = 12) healthy subjects. In addition to corroborating findings from our previous study using a spirometer for calibration, we found that the calibration procedure using an IS resulted in a fixed bias of -0.051 L and a RMSE of 0.189 ± 0.074 L corresponding to 18.559% ± 6.579% when normalized. Although it has a small underestimation and slightly increased error, the proposed calibration procedure using an IS has the advantages of being simple, fast, and affordable. This study supports the feasibility of developing a portable smartphone-based breathing status monitor that provides information about breathing depth, in addition to the more commonly estimated respiratory rate, on a daily basis.

  8. Employing an Incentive Spirometer to Calibrate Tidal Volumes Estimated from a Smartphone Camera

    PubMed Central

    Reyes, Bersain A.; Reljin, Natasa; Kong, Youngsun; Nam, Yunyoung; Ha, Sangho; Chon, Ki H.

    2016-01-01

    A smartphone-based tidal volume (VT) estimator was recently introduced by our research group, where an Android application provides a chest movement signal whose peak-to-peak amplitude is highly correlated with reference VT measured by a spirometer. We found a Normalized Root Mean Squared Error (NRMSE) of 14.998% ± 5.171% (mean ± SD) when the smartphone measures were calibrated using spirometer data. However, the availability of a spirometer device for calibration is not realistic outside clinical or research environments. In order to be used by the general population on a daily basis, a simple calibration procedure not relying on specialized devices is required. In this study, we propose taking advantage of the linear correlation between smartphone measurements and VT to obtain a calibration model using information computed while the subject breathes through a commercially-available incentive spirometer (IS). Experiments were performed on twelve (N = 12) healthy subjects. In addition to corroborating findings from our previous study using a spirometer for calibration, we found that the calibration procedure using an IS resulted in a fixed bias of −0.051 L and a RMSE of 0.189 ± 0.074 L corresponding to 18.559% ± 6.579% when normalized. Although it has a small underestimation and slightly increased error, the proposed calibration procedure using an IS has the advantages of being simple, fast, and affordable. This study supports the feasibility of developing a portable smartphone-based breathing status monitor that provides information about breathing depth, in addition to the more commonly estimated respiratory rate, on a daily basis. PMID:26999152

  9. Multi-tiered S-SOA, Parameter-Driven New Islamic Syariah Products of Holistic Islamic Banking System (HiCORE): Virtual Banking Environment

    NASA Astrophysics Data System (ADS)

    Halimah, B. Z.; Azlina, A.; Sembok, T. M.; Sufian, I.; Sharul Azman, M. N.; Azuraliza, A. B.; Zulaiha, A. O.; Nazlia, O.; Salwani, A.; Sanep, A.; Hailani, M. T.; Zaher, M. Z.; Azizah, J.; Nor Faezah, M. Y.; Choo, W. O.; Abdullah, Chew; Sopian, B.

    The Holistic Islamic Banking System (HiCORE), a banking system suitable for virtual banking environment, created based on universityindustry collaboration initiative between Universiti Kebangsaan Malaysia (UKM) and Fuziq Software Sdn Bhd. HiCORE was modeled on a multitiered Simple - Services Oriented Architecture (S-SOA), using the parameterbased semantic approach. HiCORE's existence is timely as the financial world is looking for a new approach to creating banking and financial products that are interest free or based on the Islamic Syariah principles and jurisprudence. An interest free banking system has currently caught the interest of bankers and financiers all over the world. HiCORE's Parameter-based module houses the Customer-information file (CIF), Deposit and Financing components. The Parameter based module represents the third tier of the multi-tiered Simple SOA approach. This paper highlights the multi-tiered parameter- driven approach to the creation of new Islamiic products based on the 'dalil' (Quran), 'syarat' (rules) and 'rukun' (procedures) as required by the syariah principles and jurisprudence reflected by the semantic ontology embedded in the parameter module of the system.

  10. Laser Speckle Photography: Some Simple Experiments for the Undergraduate Laboratory.

    ERIC Educational Resources Information Center

    Bates, B.; And Others

    1986-01-01

    Describes simple speckle photography experiments which are easy to set up and require only low cost standard laboratory equipment. Included are procedures for taking single, double, and multiple exposures. (JN)

  11. Aviation and programmatic analyses; Volume 1, Task 1: Aviation data base development and application. [for NASA OAST programs

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A method was developed for using the NASA aviation data base and computer programs in conjunction with the GE management analysis and projection service to perform simple and complex economic analysis for planning, forecasting, and evaluating OAST programs. Capabilities of the system are discussed along with procedures for making basic data tabulations, updates and entries. The system is applied in an agricultural aviation study in order to assess its value for actual utility in the OAST working environment.

  12. A method for generating reliable atomistic models of amorphous polymers based on a random search of energy minima

    NASA Astrophysics Data System (ADS)

    Curcó, David; Casanovas, Jordi; Roca, Marc; Alemán, Carlos

    2005-07-01

    A method for generating atomistic models of dense amorphous polymers is presented. The method is organized in a two-steps procedure. First, structures are generated using an algorithm that minimizes the torsional strain. After this, a relaxation algorithm is applied to minimize the non-bonding interactions. Two alternative relaxation methods, which are based simple minimization and Concerted Rotation techniques, have been implemented. The performance of the method has been checked by simulating polyethylene, polypropylene, nylon 6, poly(L,D-lactic acid) and polyglycolic acid.

  13. General Analytical Procedure for Determination of Acidity Parameters of Weak Acids and Bases

    PubMed Central

    Pilarski, Bogusław; Kaliszan, Roman; Wyrzykowski, Dariusz; Młodzianowski, Janusz; Balińska, Agata

    2015-01-01

    The paper presents a new convenient, inexpensive, and reagent-saving general methodology for the determination of pK a values for components of the mixture of diverse chemical classes weak organic acids and bases in water solution, without the need to separate individual analytes. The data obtained from simple pH-metric microtitrations are numerically processed into reliable pK a values for each component of the mixture. Excellent agreement has been obtained between the determined pK a values and the reference literature data for compounds studied. PMID:25692072

  14. General analytical procedure for determination of acidity parameters of weak acids and bases.

    PubMed

    Pilarski, Bogusław; Kaliszan, Roman; Wyrzykowski, Dariusz; Młodzianowski, Janusz; Balińska, Agata

    2015-01-01

    The paper presents a new convenient, inexpensive, and reagent-saving general methodology for the determination of pK a values for components of the mixture of diverse chemical classes weak organic acids and bases in water solution, without the need to separate individual analytes. The data obtained from simple pH-metric microtitrations are numerically processed into reliable pK a values for each component of the mixture. Excellent agreement has been obtained between the determined pK a values and the reference literature data for compounds studied.

  15. A simplified gis-based model for large wood recruitment and connectivity in mountain basins

    NASA Astrophysics Data System (ADS)

    Franceschi, Silvia; Antonello, Andrea; Vela, Ana Lucia; Cavalli, Marco; Crema, Stefano; Comiti, Francesco; Tonon, Giustino

    2015-04-01

    During the last 50 years in the Alps the decline of the rural and forest economy and at the depopulation of the mountain areas caused the progressive abandon of the land in general and in particular of the riparian zones and the consequent increment of the vegetation extension. On one hand the wood increases the availability of organic matter and has positive effects on mountain river systems. However, during flooding events large woods that reach the stream cause the clogging of bridges with an increase of flood hazard. The approach to the evaluation of the availability of large wood during flooding events is still a challenge. There are models that simulate the propagation of the logs downstream, but the evaluation of the trees that can reach the stream is still done using simplified GIS procedures. These procedures are the base for our research which will include LiDAR derived information on vegetation to evaluate large wood recruitment extreme events. Within the last Google Summer of Code (2014) we developed a set of tools to evaluate large wood recruitment and propagation along the channel network based on a simplified methodology for monitoring and modeling large wood recruitment and transport in mountain basins implemented by Lucía et 2014. These tools are integrated in the JGrassTools project as a dedicated section in the Hydro-Geomorphology library. The section LWRecruitment contains 10 simple modules that allow the user to start from very simple information related to geomorphology, flooding areas and vegetation cover and obtain a map of the most probable critical sections on the streams. The tools cover the two main aspects related to the iteration of large wood with the rivers: the recruitment mechanisms and the propagation downstream. While the propagation tool is very simple and does not consider the hydrodynamic of the problem, the recruitment algorithms are more specific and consider the influence of hillslopes stability and the flooding extension. The modules are available for download at www.jgrasstools.org. A simple and easy to use graphical interface to run the models is available at https://github.com/moovida/STAGE/releases.

  16. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  17. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  18. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  19. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  20. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  1. Transfascial vaginal tape (TFT): a simple, safe and cost-effective procedure for stress urinary incontinence. A preliminary study.

    PubMed

    Foglia, Giovanni; Mistrangelo, Emanuela; Lijoi, Davide; Alessandri, Franco; Ragni, Nicola

    2007-07-01

    To analyse prospectively the effectiveness of a new simple, minimally invasive, and cost-effective technique for the treatment of female urinary stress incontinence: the transfascial vaginal tape (TFT). In a prospective study, we enrolled 45 women undergoing TFT with or without hysterectomy and/or another pelvic reconstructive procedure between 1st December 2003 and 31st December. TFT consists of a tension-free urethrosuspension using a sling located at the mid-urethral level and placed laterally in the endopelvic fascia previously perforated. Follow-up evaluations were established at 3 and 6 months and at 1 year after the operation. During each follow-up, women underwent cough stress test and they answered to the "Incontinence quality of life questionnaire" (I-QOL), to the Patient Global Impression of Severity (PGI-S) and of Improvement (PGI-I) questions. Thirty-nine patients (88.9%) had a follow-up examination 1 year after surgery. Of these, 30 (76.9%) were defined cured, 6 (15.4%) improved and 3 (7.7%) failed. TFT procedure can be considered a simple, safe and cost-effective procedure for the treatment of stress urinary incontinence and can be an alternative to tension-free vaginal tape or transobturator route for sub-urethral tape procedures.

  2. Vibration based algorithm for crack detection in cantilever beam containing two different types of cracks

    NASA Astrophysics Data System (ADS)

    Behzad, Mehdi; Ghadami, Amin; Maghsoodi, Ameneh; Michael Hale, Jack

    2013-11-01

    In this paper, a simple method for detection of multiple edge cracks in Euler-Bernoulli beams having two different types of cracks is presented based on energy equations. Each crack is modeled as a massless rotational spring using Linear Elastic Fracture Mechanics (LEFM) theory, and a relationship among natural frequencies, crack locations and stiffness of equivalent springs is demonstrated. In the procedure, for detection of m cracks in a beam, 3m equations and natural frequencies of healthy and cracked beam in two different directions are needed as input to the algorithm. The main accomplishment of the presented algorithm is the capability to detect the location, severity and type of each crack in a multi-cracked beam. Concise and simple calculations along with accuracy are other advantages of this method. A number of numerical examples for cantilever beams including one and two cracks are presented to validate the method.

  3. Numerical tilting compensation in microscopy based on wavefront sensing using transport of intensity equation method

    NASA Astrophysics Data System (ADS)

    Hu, Junbao; Meng, Xin; Wei, Qi; Kong, Yan; Jiang, Zhilong; Xue, Liang; Liu, Fei; Liu, Cheng; Wang, Shouyu

    2018-03-01

    Wide-field microscopy is commonly used for sample observations in biological research and medical diagnosis. However, the tilting error induced by the oblique location of the image recorder or the sample, as well as the inclination of the optical path often deteriorates the imaging quality. In order to eliminate the tilting in microscopy, a numerical tilting compensation technique based on wavefront sensing using transport of intensity equation method is proposed in this paper. Both the provided numerical simulations and practical experiments prove that the proposed technique not only accurately determines the tilting angle with simple setup and procedures, but also compensates the tilting error for imaging quality improvement even in the large tilting cases. Considering its simple systems and operations, as well as image quality improvement capability, it is believed the proposed method can be applied for tilting compensation in the optical microscopy.

  4. Application of Certain π-Acceptors for the Spectrophotometric Determination of Alendronate Sodium in Pharmaceutical Bulk and Dosage Forms.

    PubMed

    Raza, Asad; Zia-Ul-Haq, Muhammad

    2011-01-01

    Two simple, fast, and accurate spectrophotometric methods for the determination of alendronate sodium are described. The methods are based on charge-transfer complex formation of the drug with two π-electron acceptors 7,7,7,8-tetracyanoquinodimethane (TCNQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in acetonitrile and methanol medium. The methods are followed spectrophotometrically by measuring the maximum absorbance at 840 nm and 465 nm, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 2-10 μg mL(-1) and 2-12 μg mL(-1), respectively. The optimal reactions conditions values such as the reagent concentration, heating time, and stability of reaction product were determined. No significant difference was obtained between the results of newly proposed methods and the B.P. Titrimetric procedures. The charge transfer approach using TCNQ and DDQ procedures described in this paper is simple, fast, accurate, precise, and extraction-free.

  5. Procedure for measuring simultaneously the solar and visible properties of glazing with complex internal or external structures.

    PubMed

    Gentle, A R; Smith, G B

    2014-10-20

    Accurate solar and visual transmittances of materials in which surfaces or internal structures are complex are often not easily amenable to standard procedures with laboratory-based spectrophotometers and integrating spheres. Localized "hot spots" of intensity are common in such materials, so data on small samples is unreliable. A novel device and simple protocols have been developed and undergone validation testing. Simultaneous solar and visible transmittance and reflectance data have been acquired for skylight components and multilayer polycarbonate roof panels. The pyranometer and lux sensor setups also directly yield "light coolness" in lumens/watt. Sample areas must be large, and, although mainly in sheet form, some testing has been done on curved panels. The instrument, its operation, and the simple calculations used are described. Results on a subset of diffuse and partially diffuse materials with no hot spots have been cross checked using 150 mm integrating spheres with a spectrophotometer and the Air Mass 1.5 spectrum. Indications are that results are as good or better than with such spheres for transmittance, but reflectance techniques need refinement for some sample types.

  6. Application of Certain π-Acceptors for the Spectrophotometric Determination of Alendronate Sodium in Pharmaceutical Bulk and Dosage Forms

    PubMed Central

    Raza, Asad; Zia-ul-Haq, Muhammad

    2011-01-01

    Two simple, fast, and accurate spectrophotometric methods for the determination of alendronate sodium are described. The methods are based on charge-transfer complex formation of the drug with two π-electron acceptors 7,7,7,8-tetracyanoquinodimethane (TCNQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in acetonitrile and methanol medium. The methods are followed spectrophotometrically by measuring the maximum absorbance at 840 nm and 465 nm, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 2–10 μg mL−1 and 2–12 μg mL−1, respectively. The optimal reactions conditions values such as the reagent concentration, heating time, and stability of reaction product were determined. No significant difference was obtained between the results of newly proposed methods and the B.P. Titrimetric procedures. The charge transfer approach using TCNQ and DDQ procedures described in this paper is simple, fast, accurate, precise, and extraction-free. PMID:21760789

  7. Accurate Behavioral Simulator of All-Digital Time-Domain Smart Temperature Sensors by Using SIMULINK

    PubMed Central

    Chen, Chun-Chi; Chen, Chao-Lieh; Lin, You-Ting

    2016-01-01

    This study proposes a new behavioral simulator that uses SIMULINK for all-digital CMOS time-domain smart temperature sensors (TDSTSs) for performing rapid and accurate simulations. Inverter-based TDSTSs offer the benefits of low cost and simple structure for temperature-to-digital conversion and have been developed. Typically, electronic design automation tools, such as HSPICE, are used to simulate TDSTSs for performance evaluations. However, such tools require extremely long simulation time and complex procedures to analyze the results and generate figures. In this paper, we organize simple but accurate equations into a temperature-dependent model (TDM) by which the TDSTSs evaluate temperature behavior. Furthermore, temperature-sensing models of a single CMOS NOT gate were devised using HSPICE simulations. Using the TDM and these temperature-sensing models, a novel simulator in SIMULINK environment was developed to substantially accelerate the simulation and simplify the evaluation procedures. Experiments demonstrated that the simulation results of the proposed simulator have favorable agreement with those obtained from HSPICE simulations, showing that the proposed simulator functions successfully. This is the first behavioral simulator addressing the rapid simulation of TDSTSs. PMID:27509507

  8. A statistical method for measuring activation of gene regulatory networks.

    PubMed

    Esteves, Gustavo H; Reis, Luiz F L

    2018-06-13

    Gene expression data analysis is of great importance for modern molecular biology, given our ability to measure the expression profiles of thousands of genes and enabling studies rooted in systems biology. In this work, we propose a simple statistical model for the activation measuring of gene regulatory networks, instead of the traditional gene co-expression networks. We present the mathematical construction of a statistical procedure for testing hypothesis regarding gene regulatory network activation. The real probability distribution for the test statistic is evaluated by a permutation based study. To illustrate the functionality of the proposed methodology, we also present a simple example based on a small hypothetical network and the activation measuring of two KEGG networks, both based on gene expression data collected from gastric and esophageal samples. The two KEGG networks were also analyzed for a public database, available through NCBI-GEO, presented as Supplementary Material. This method was implemented in an R package that is available at the BioConductor project website under the name maigesPack.

  9. Algorithmic commonalities in the parallel environment

    NASA Technical Reports Server (NTRS)

    Mcanulty, Michael A.; Wainer, Michael S.

    1987-01-01

    The ultimate aim of this project was to analyze procedures from substantially different application areas to discover what is either common or peculiar in the process of conversion to the Massively Parallel Processor (MPP). Three areas were identified: molecular dynamic simulation, production systems (rule systems), and various graphics and vision algorithms. To date, only selected graphics procedures have been investigated. They are the most readily available, and produce the most visible results. These include simple polygon patch rendering, raycasting against a constructive solid geometric model, and stochastic or fractal based textured surface algorithms. Only the simplest of conversion strategies, mapping a major loop to the array, has been investigated so far. It is not entirely satisfactory.

  10. A filter paper dry blood spot procedure for acute intermittent porphyria population screening by use of whole blood uroporphyrinogen-I-synthase assay.

    PubMed

    Johansson, L; Thunell, S; Wetterberg, L

    1984-03-13

    A filter paper dry blood spot procedure for the determination of whole blood uroporphyrinogen-I-synthase (UIS) activity is presented. The method is based on the concept of enzyme specific activity, the enzyme activity being related to the haemoglobin concentration of the assay sample. The diagnostic capacity with regard to the acute intermittent porphyria (AIP) gene carrier state is shown to be equivalent to that of a washed red cell reference method. On grounds of easy capillary blood sampling, uncomplicated and safe mail specimen transport and simple laboratory reception routines, the method is stated to be well adapted for use in AIP preadolescent population screening.

  11. A Simple Experiment Demonstrating the Allosteric Regulation of Yeast Pyruvate Kinase.

    ERIC Educational Resources Information Center

    Taber, Richard L.; Campbell, Angela; Spencer, Scott

    1998-01-01

    Explains the procedures used to determine the regulatory properties of yeast pyruvate kinase. Involves a partial purification using PEG precipitation that can be done in one laboratory period with simple equipment. (DDR)

  12. A simple procedure for retrieval of a cement-retained implant-supported crown: a case report.

    PubMed

    Buzayan, Muaiyed Mahmoud; Mahmood, Wan Adida; Yunus, Norsiah Binti

    2014-02-01

    Retrieval of cement-retained implant prostheses can be more demanding than retrieval of screw-retained prostheses. This case report describes a simple and predictable procedure to locate the abutment screw access openings of cementretained implant-supported crowns in cases of fractured ceramic veneer. A conventional periapical radiography image was captured using a digital camera, transferred to a computer, and manipulated using Microsoft Word document software to estimate the location of the abutment screw access.

  13. The International Ultraviolet Explorer: Case study in spacecraft design

    NASA Technical Reports Server (NTRS)

    Freeman, H. R.; Longanecker, G. W.

    1979-01-01

    The International Ultraviolet Explorer (IUE) is a geosynchronous scientific satellite that was conceived as an international space observatory capable of measuring UV spectra of faint celestial bodies. Simple operational procedures allow the astronomers to joystick the spaceborne telescope about the sky, using familiar ground-based observatory techniques. The present paper deals with the IUE project objectives, the technical problems, constraints, trade-offs, and the problem solving techniques used in the IUE program.

  14. A verification library for multibody simulation software

    NASA Technical Reports Server (NTRS)

    Kim, Sung-Soo; Haug, Edward J.; Frisch, Harold P.

    1989-01-01

    A multibody dynamics verification library, that maintains and manages test and validation data is proposed, based on RRC Robot arm and CASE backhoe validation and a comparitive study of DADS, DISCOS, and CONTOPS that are existing public domain and commercial multibody dynamic simulation programs. Using simple representative problems, simulation results from each program are cross checked, and the validation results are presented. Functionalities of the verification library are defined, in order to automate validation procedure.

  15. Radiofrequency Ablation of Lung Tumors

    MedlinePlus

    ... the procedure. top of page What does the equipment look like? In this procedure, computed tomography (CT) ... electrical generator and grounding pads are used. Radiofrequency equipment There are two types of needle electrodes: simple ...

  16. Radiofrequency Ablation of Liver Tumors

    MedlinePlus

    ... the procedure. top of page What does the equipment look like? The equipment used in this procedure ... and grounding pads may also be used. Radiofrequency equipment There are two types of needle electrodes: simple ...

  17. Flowfield computation of entry vehicles

    NASA Technical Reports Server (NTRS)

    Prabhu, Dinesh K.

    1990-01-01

    The equations governing the multidimensional flow of a reacting mixture of thermally perfect gasses were derived. The modeling procedures for the various terms of the conservation laws are discussed. A numerical algorithm, based on the finite-volume approach, to solve these conservation equations was developed. The advantages and disadvantages of the present numerical scheme are discussed from the point of view of accuracy, computer time, and memory requirements. A simple one-dimensional model problem was solved to prove the feasibility and accuracy of the algorithm. A computer code implementing the above algorithm was developed and is presently being applied to simple geometries and conditions. Once the code is completely debugged and validated, it will be used to compute the complete unsteady flow field around the Aeroassist Flight Experiment (AFE) body.

  18. Design of a global soil moisture initialization procedure for the simple biosphere model

    NASA Technical Reports Server (NTRS)

    Liston, G. E.; Sud, Y. C.; Walker, G. K.

    1993-01-01

    Global soil moisture and land-surface evapotranspiration fields are computed using an analysis scheme based on the Simple Biosphere (SiB) soil-vegetation-atmosphere interaction model. The scheme is driven with observed precipitation, and potential evapotranspiration, where the potential evapotranspiration is computed following the surface air temperature-potential evapotranspiration regression of Thomthwaite (1948). The observed surface air temperature is corrected to reflect potential (zero soil moisture stress) conditions by letting the ratio of actual transpiration to potential transpiration be a function of normalized difference vegetation index (NDVI). Soil moisture, evapotranspiration, and runoff data are generated on a daily basis for a 10-year period, January 1979 through December 1988, using observed precipitation gridded at a 4 deg by 5 deg resolution.

  19. Simple real-time computerized tasks for detection of malingering among murderers with schizophrenia.

    PubMed

    Kertzman, Semion; Grinspan, Haim; Birger, Moshe; Shliapnikov, Nina; Alish, Yakov; Ben Nahum, Zeev; Mester, Roberto; Kotler, Moshe

    2006-01-01

    It is our contention that computer-based two-alternative forced choice techniques can be useful tools for the detection of patients with schizophrenia who feign acute psychotic symptoms and cognitive impairment as opposed to patients with schizophrenia with a true active psychosis. In our experiment, Visual Simple and Choice Reaction Time tasks were used. Reaction time in milliseconds was recorded and accuracy rate was obtained for all subjects' responses. Both types of task were administered to 27 patients with schizophrenia suspected of having committed murder. Patients with schizophrenia who were clinically assessed as malingerers achieved significantly fewer correct results, were significantly slower and less consistent in their reaction time. Congruence of performance between the Simple and Choice tasks was an additional parameter for the accurate diagnosis of malingering. The four parameters of both tests (accuracy of response, reaction time, standard deviation of reaction time and task congruency) are simple and constitute a user-friendly means for the detection of malingering in forensic practice. Another advantage of this procedure is that the software automatically measures and evaluates all the parameters.

  20. Homogenization of Large-Scale Movement Models in Ecology

    USGS Publications Warehouse

    Garlick, M.J.; Powell, J.A.; Hooten, M.B.; McFarlane, L.R.

    2011-01-01

    A difficulty in using diffusion models to predict large scale animal population dispersal is that individuals move differently based on local information (as opposed to gradients) in differing habitat types. This can be accommodated by using ecological diffusion. However, real environments are often spatially complex, limiting application of a direct approach. Homogenization for partial differential equations has long been applied to Fickian diffusion (in which average individual movement is organized along gradients of habitat and population density). We derive a homogenization procedure for ecological diffusion and apply it to a simple model for chronic wasting disease in mule deer. Homogenization allows us to determine the impact of small scale (10-100 m) habitat variability on large scale (10-100 km) movement. The procedure generates asymptotic equations for solutions on the large scale with parameters defined by small-scale variation. The simplicity of this homogenization procedure is striking when compared to the multi-dimensional homogenization procedure for Fickian diffusion,and the method will be equally straightforward for more complex models. ?? 2010 Society for Mathematical Biology.

  1. Human health risk assessment: models for predicting the effective exposure duration of on-site receptors exposed to contaminated groundwater.

    PubMed

    Baciocchi, Renato; Berardi, Simona; Verginelli, Iason

    2010-09-15

    Clean-up of contaminated sites is usually based on a risk-based approach for the definition of the remediation goals, which relies on the well known ASTM-RBCA standard procedure. In this procedure, migration of contaminants is described through simple analytical models and the source contaminants' concentration is supposed to be constant throughout the entire exposure period, i.e. 25-30 years. The latter assumption may often result over-protective of human health, leading to unrealistically low remediation goals. The aim of this work is to propose an alternative model taking in account the source depletion, while keeping the original simplicity and analytical form of the ASTM-RBCA approach. The results obtained by the application of this model are compared with those provided by the traditional ASTM-RBCA approach, by a model based on the source depletion algorithm of the RBCA ToolKit software and by a numerical model, allowing to assess its feasibility for inclusion in risk analysis procedures. The results discussed in this work are limited to on-site exposure to contaminated water by ingestion, but the approach proposed can be extended to other exposure pathways. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Biosensor technology for the detection of illegal drugs II: antibody development and detection techniques

    NASA Astrophysics Data System (ADS)

    Hilpert, Reinhold; Bauer, Christian; Binder, Florian; Grol, Michael; Hallermayer, Klaus; Josel, Hans-Peter; Klein, Christian; Maier, Josef; Makower, Alexander; Oberpriller, Helmut; Ritter, Josef

    1994-10-01

    In a joint project of Deutsche Aerospace, Boehringer Mannheim and the University of Potsdam portable devices for the detection of illegal drugs, based on biosensor technology, are being developed. The concept enrichment of the drug from the gas phase and detection by immunological means. This publication covers the development of specific antibodies and various detection procedures. Antibodies with a high affinity for cocaine have been developed with the aid of specially synthesized immunogens. A competitive detection procedure with biosensors based on optical grating couplers and applying particulate labels has been established, showing a lower detection limit of 10-10 mol/l for cocaine. Additionally, a combination of a displacement-immunoreactor and an enzymatically amplified electrode was investigated, which at present still suffers from insufficient sensitivity of the immunoreactor. An alternative, fleece-matrix based test procedure, where enrichment and detection steps are integrated in a single unit, is promising in terms of simplicity and sensitivity. A simple swab-test for the detection of cocaine at surfaces has been developed, which has a lower detection limit of about 10 ng and which can be performed within one minute.

  3. 49 CFR 1141.1 - Procedures to calculate interest rates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the portion of the year covered by the interest rate. A simple multiplication of the nominal rate by... 49 Transportation 8 2010-10-01 2010-10-01 false Procedures to calculate interest rates. 1141.1... TRANSPORTATION BOARD, DEPARTMENT OF TRANSPORTATION RULES OF PRACTICE PROCEDURES TO CALCULATE INTEREST RATES...

  4. Theoretical performance analysis of doped optical fibers based on pseudo parameters

    NASA Astrophysics Data System (ADS)

    Karimi, Maryam; Seraji, Faramarz E.

    2010-09-01

    Characterization of doped optical fibers (DOFs) is an essential primary stage for design of DOF-based devices. This paper presents design of novel measurement techniques to determine DOFs parameters using mono-beam propagation in a low-loss medium by generating pseudo parameters for the DOFs. The designed techniques are able to characterize simultaneously the absorption, emission cross-sections (ACS and ECS), and dopant concentration of DOFs. In both the proposed techniques, we assume pseudo parameters for the DOFs instead of their actual values and show that the choice of these pseudo parameters values for design of DOF-based devices, such as erbium-doped fiber amplifier (EDFA), are appropriate and the resulting error is quite negligible when compared with the actual parameters values.Utilization of pseudo ACS and ECS values in design procedure of EDFAs does not require the measurement of background loss coefficient (BLC) and makes the rate equation of the DOFs simple. It is shown that by using the pseudo parameters values obtained by the proposed techniques, the error in the gain of a designed EDFA with a BLC of about 1 dB/km, are about 0.08 dB. It is further indicated that the same scenario holds good for BLC lower than 5 dB/m and higher than 12 dB/m. The proposed characterization techniques have simple procedures and are low cost that can have an advantageous use in manufacturing of the DOFs.

  5. A Simple Illustration for the Need of Multiple Comparison Procedures

    ERIC Educational Resources Information Center

    Carter, Rickey E.

    2010-01-01

    Statistical adjustments to accommodate multiple comparisons are routinely covered in introductory statistical courses. The fundamental rationale for such adjustments, however, may not be readily understood. This article presents a simple illustration to help remedy this.

  6. A rule-based software test data generator

    NASA Technical Reports Server (NTRS)

    Deason, William H.; Brown, David B.; Chang, Kai-Hsiung; Cross, James H., II

    1991-01-01

    Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

  7. Using Three-Dimensional Printing to Fabricate a Tubing Connector for Dilation and Evacuation.

    PubMed

    Stitely, Michael L; Paterson, Helen

    2016-02-01

    This is a proof-of-concept study to show that simple instrumentation problems encountered in surgery can be solved by fabricating devices using a three-dimensional printer. The device used in the study is a simple tubing connector fashioned to connect two segments of suction tubing used in a surgical procedure where no commercially available product for this use is available through our usual suppliers in New Zealand. A cylindrical tubing connector was designed using three-dimensional printing design software. The tubing connector was fabricated using the Makerbot Replicator 2X three-dimensional printer. The connector was used in 15 second-trimester dilation and evacuation procedures. Data forms were completed by the primary operating surgeon. Descriptive statistics were used with the expectation that the device would function as intended in all cases. The three-dimensional printed tubing connector functioned as intended in all 15 instances. Commercially available three-dimensional printing technology can be used to overcome simple instrumentation problems encountered during gynecologic surgical procedures.

  8. Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum.

    PubMed

    Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing

    2014-05-01

    Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of P. falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8-24 h followed by routine culture. When cultures with 27-60% of ring stage were synchronized using this procedure, 70-93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum

    PubMed Central

    Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M.; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing

    2014-01-01

    Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of Plasmodium falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8–24 h followed by routine culture. When cultures with 27–60% of ring stage were synchronized using this procedure, 70–93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. PMID:24632190

  10. Poster — Thur Eve — 52: A Web-based Platform for Collaborative Document Management in Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kildea, J.; Joseph, A.

    We describe DepDocs, a web-based platform that we have developed to manage the committee meetings, policies, procedures and other documents within our otherwise paperless radiotherapy clinic. DepDocs is essentially a document management system based on the popular Drupal content management software. For security and confidentiality, it is hosted on a linux server internal to our hospital network such that documents are never sent to the cloud or outside of the hospital firewall. We used Drupal's in-built role-based user rights management system to assign a role, and associated document editing rights, to each user. Documents are accessed for viewing using eithermore » a simple Google-like search or by generating a list of related documents from a taxonomy of categorization terms. Our system provides document revision tracking and an document review and approval mechanism for all official policies and procedures. Committee meeting schedules, agendas and minutes are maintained by committee chairs and are restricted to committee members. DepDocs has been operational within our department for over six months and has already 45 unique users and an archive of over 1000 documents, mostly policies and procedures. Documents are easily retrievable from the system using any web browser within our hospital's network.« less

  11. Conditional Monte Carlo randomization tests for regression models.

    PubMed

    Parhat, Parwen; Rosenberger, William F; Diao, Guoqing

    2014-08-15

    We discuss the computation of randomization tests for clinical trials of two treatments when the primary outcome is based on a regression model. We begin by revisiting the seminal paper of Gail, Tan, and Piantadosi (1988), and then describe a method based on Monte Carlo generation of randomization sequences. The tests based on this Monte Carlo procedure are design based, in that they incorporate the particular randomization procedure used. We discuss permuted block designs, complete randomization, and biased coin designs. We also use a new technique by Plamadeala and Rosenberger (2012) for simple computation of conditional randomization tests. Like Gail, Tan, and Piantadosi, we focus on residuals from generalized linear models and martingale residuals from survival models. Such techniques do not apply to longitudinal data analysis, and we introduce a method for computation of randomization tests based on the predicted rate of change from a generalized linear mixed model when outcomes are longitudinal. We show, by simulation, that these randomization tests preserve the size and power well under model misspecification. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Fostering Formal Commutativity Knowledge with Approximate Arithmetic

    PubMed Central

    Hansen, Sonja Maria; Haider, Hilde; Eichler, Alexandra; Godau, Claudia; Frensch, Peter A.; Gaschler, Robert

    2015-01-01

    How can we enhance the understanding of abstract mathematical principles in elementary school? Different studies found out that nonsymbolic estimation could foster subsequent exact number processing and simple arithmetic. Taking the commutativity principle as a test case, we investigated if the approximate calculation of symbolic commutative quantities can also alter the access to procedural and conceptual knowledge of a more abstract arithmetic principle. Experiment 1 tested first graders who had not been instructed about commutativity in school yet. Approximate calculation with symbolic quantities positively influenced the use of commutativity-based shortcuts in formal arithmetic. We replicated this finding with older first graders (Experiment 2) and third graders (Experiment 3). Despite the positive effect of approximation on the spontaneous application of commutativity-based shortcuts in arithmetic problems, we found no comparable impact on the application of conceptual knowledge of the commutativity principle. Overall, our results show that the usage of a specific arithmetic principle can benefit from approximation. However, the findings also suggest that the correct use of certain procedures does not always imply conceptual understanding. Rather, the conceptual understanding of commutativity seems to lag behind procedural proficiency during elementary school. PMID:26560311

  13. First Experiences with the New Senhance® Telerobotic System in Visceral Surgery.

    PubMed

    Stephan, Dietmar; Sälzer, Heike; Willeke, Frank

    2018-02-01

    Until recently, robotic-assisted surgery has exclusively been connected to the name DaVinci®. In 2016, a second robotic system, the Senhance®, became available. To introduce the new robotic system into clinical routine, detailed team training and an integration program were useful. Within the first 6 months, 116 cases were performed with this system. The integration program intended to start with simple and well-standardized clinical cases. We chose inguinal hernia repair using the TAPP (transabdominal preperitoneal) technique as the starting procedure. Subsequently, we added upper gastrointestinal surgery and cholecystectomies, and colorectal procedures have since also been included. Initial experience with the Senhance system as the first installation in Germany shows that it is suitable for surgery in general and for visceral surgery in particular. The application is safe due to the unproblematically quick changeover to normal laparoscopy and easy to integrate due to the very short system integration times (docking times). Since it is a laparoscopic-based system, following an integration program will enable experienced laparoscopic surgeons to very quickly manage more complex procedures. Due to lower costs, introducing robotic surgery starting with simple and standardized procedures is more feasible. After the establishment of this second robotic system, future studies will have to specifically look at differences in surgical results and basic conditions of different robotic-assisted systems. This paper documents the decision-making process of a hospital towards the integration of a robotic system and the selection criteria used while also demonstrating the planning and execution process during the introduction of the system into clinical routine.

  14. Self-constrained inversion of potential fields

    NASA Astrophysics Data System (ADS)

    Paoletti, V.; Ialongo, S.; Florio, G.; Fedi, M.; Cella, F.

    2013-11-01

    We present a potential-field-constrained inversion procedure based on a priori information derived exclusively from the analysis of the gravity and magnetic data (self-constrained inversion). The procedure is designed to be applied to underdetermined problems and involves scenarios where the source distribution can be assumed to be of simple character. To set up effective constraints, we first estimate through the analysis of the gravity or magnetic field some or all of the following source parameters: the source depth-to-the-top, the structural index, the horizontal position of the source body edges and their dip. The second step is incorporating the information related to these constraints in the objective function as depth and spatial weighting functions. We show, through 2-D and 3-D synthetic and real data examples, that potential field-based constraints, for example, structural index, source boundaries and others, are usually enough to obtain substantial improvement in the density and magnetization models.

  15. Procedure Enabling Simulation and In-Depth Analysis of Optical Effects in Camera-Based Time-Of Sensors

    NASA Astrophysics Data System (ADS)

    Baumgart, M.; Druml, N.; Consani, M.

    2018-05-01

    This paper presents a simulation approach for Time-of-Flight cameras to estimate sensor performance and accuracy, as well as to help understanding experimentally discovered effects. The main scope is the detailed simulation of the optical signals. We use a raytracing-based approach and use the optical path length as the master parameter for depth calculations. The procedure is described in detail with references to our implementation in Zemax OpticStudio and Python. Our simulation approach supports multiple and extended light sources and allows accounting for all effects within the geometrical optics model. Especially multi-object reflection/scattering ray-paths, translucent objects, and aberration effects (e.g. distortion caused by the ToF lens) are supported. The optical path length approach also enables the implementation of different ToF senor types and transient imaging evaluations. The main features are demonstrated on a simple 3D test scene.

  16. Adaptive segmentation of nuclei in H&S stained tendon microscopy

    NASA Astrophysics Data System (ADS)

    Chuang, Bo-I.; Wu, Po-Ting; Hsu, Jian-Han; Jou, I.-Ming; Su, Fong-Chin; Sun, Yung-Nien

    2015-12-01

    Tendiopathy is a popular clinical issue in recent years. In most cases like trigger finger or tennis elbow, the pathology change can be observed under H and E stained tendon microscopy. However, the qualitative analysis is too subjective and thus the results heavily depend on the observers. We develop an automatic segmentation procedure which segments and counts the nuclei in H and E stained tendon microscopy fast and precisely. This procedure first determines the complexity of images and then segments the nuclei from the image. For the complex images, the proposed method adopts sampling-based thresholding to segment the nuclei. While for the simple images, the Laplacian-based thresholding is employed to re-segment the nuclei more accurately. In the experiments, the proposed method is compared with the experts outlined results. The nuclei number of proposed method is closed to the experts counted, and the processing time of proposed method is much faster than the experts'.

  17. Infrared Sensor-Based Temperature Control for Domestic Induction Cooktops

    PubMed Central

    Lasobras, Javier; Alonso, Rafael; Carretero, Claudio; Carretero, Enrique; Imaz, Eduardo

    2014-01-01

    In this paper, a precise real-time temperature control system based on infrared (IR) thermometry for domestic induction cooking is presented. The temperature in the vessel constitutes the control variable of the closed-loop power control system implemented in a commercial induction cooker. A proportional-integral controller is applied to establish the output power level in order to reach the target temperature. An optical system and a signal conditioning circuit have been implemented. For the signal processing a microprocessor with 12-bit ADC and a sampling rate of 1 Ksps has been used. The analysis of the contributions to the infrared radiation permits the definition of a procedure to estimate the temperature of the vessel with a maximum temperature error of 5 °C in the range between 60 and 250 °C for a known cookware emissivity. A simple and necessary calibration procedure with a black-body sample is presented. PMID:24638125

  18. Infrared sensor-based temperature control for domestic induction cooktops.

    PubMed

    Lasobras, Javier; Alonso, Rafael; Carretero, Claudio; Carretero, Enrique; Imaz, Eduardo

    2014-03-14

    In this paper, a precise real-time temperature control system based on infrared (IR) thermometry for domestic induction cooking is presented. The temperature in the vessel constitutes the control variable of the closed-loop power control system implemented in a commercial induction cooker. A proportional-integral controller is applied to establish the output power level in order to reach the target temperature. An optical system and a signal conditioning circuit have been implemented. For the signal processing a microprocessor with 12-bit ADC and a sampling rate of 1 Ksps has been used. The analysis of the contributions to the infrared radiation permits the definition of a procedure to estimate the temperature of the vessel with a maximum temperature error of 5 °C in the range between 60 and 250 °C for a known cookware emissivity. A simple and necessary calibration procedure with a black-body sample is presented.

  19. On fitting the Pareto Levy distribution to stock market index data: Selecting a suitable cutoff value

    NASA Astrophysics Data System (ADS)

    Coronel-Brizio, H. F.; Hernández-Montoya, A. R.

    2005-08-01

    The so-called Pareto-Levy or power-law distribution has been successfully used as a model to describe probabilities associated to extreme variations of stock markets indexes worldwide. The selection of the threshold parameter from empirical data and consequently, the determination of the exponent of the distribution, is often done using a simple graphical method based on a log-log scale, where a power-law probability plot shows a straight line with slope equal to the exponent of the power-law distribution. This procedure can be considered subjective, particularly with regard to the choice of the threshold or cutoff parameter. In this work, a more objective procedure based on a statistical measure of discrepancy between the empirical and the Pareto-Levy distribution is presented. The technique is illustrated for data sets from the New York Stock Exchange (DJIA) and the Mexican Stock Market (IPC).

  20. Compositions in II-Flat. A Prelude to Pythagoras

    ERIC Educational Resources Information Center

    Callagy, J. J.

    1971-01-01

    This article shows how simple instruments may be used to construct angles of certain measures and applies this procedure to more detailed problems. A proof of the Pythagorean Theorem is given using these procedures. (CT)

  1. Assessing the utility of phase-space-localized basis functions: Exploiting direct product structure and a new basis function selection procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, James, E-mail: 9jhb3@queensu.ca; Carrington, Tucker, E-mail: Tucker.Carrington@queensu.ca

    In this paper we show that it is possible to use an iterative eigensolver in conjunction with Halverson and Poirier’s symmetrized Gaussian (SG) basis [T. Halverson and B. Poirier, J. Chem. Phys. 137, 224101 (2012)] to compute accurate vibrational energy levels of molecules with as many as five atoms. This is done, without storing and manipulating large matrices, by solving a regular eigenvalue problem that makes it possible to exploit direct-product structure. These ideas are combined with a new procedure for selecting which basis functions to use. The SG basis we work with is orders of magnitude smaller than themore » basis made by using a classical energy criterion. We find significant convergence errors in previous calculations with SG bases. For sum-of-product Hamiltonians, SG bases large enough to compute accurate levels are orders of magnitude larger than even simple pruned bases composed of products of harmonic oscillator functions.« less

  2. Female genital mutilation reversal: a general approach.

    PubMed

    Anand, Mallika; Stanhope, Todd J; Occhino, John A

    2014-07-01

    Female genital mutilation (FGM) is a violation of human rights; yet, more than 100 million females are estimated to have undergone the procedure worldwide. There is an increased need for physician education in treating FGM. Female pelvic surgeons have a unique opportunity to treat this population of patients. Here, we depict the classification of FGM and a general approach to FGM reversal. We specifically address the procedure of type III FGM reversal, or defibulation. In this video, we first highlight the importance of the problem of FGM. Next, we present the classification of FGM using an original, simple, schematic diagram highlighting they key anatomic structures involved in the four types of FGM. We then present a simple case of reversal of type III FGM, a procedure also known as defibulation. After depicting the surgical procedure, we discuss clinical results and summarize key principles of the defibulation procedure. Our patient was a 25-year-old woman who had undergone type III FGM as a child in Somalia. She desired restoration of vaginal function. We performed a reversal, and her postoperative course was uncomplicated. By 6 weeks postoperatively, she was able to engage in sexual intercourse without dyspareunia. FGM is a problem at the doorsteps of female pelvic medicine and reconstructive surgery. Our video demonstrates a basic surgical approach that can be applied to simple cases of type III FGM presenting to the female pelvic surgeon.

  3. Logic-Based Models for the Analysis of Cell Signaling Networks†

    PubMed Central

    2010-01-01

    Computational models are increasingly used to analyze the operation of complex biochemical networks, including those involved in cell signaling networks. Here we review recent advances in applying logic-based modeling to mammalian cell biology. Logic-based models represent biomolecular networks in a simple and intuitive manner without describing the detailed biochemistry of each interaction. A brief description of several logic-based modeling methods is followed by six case studies that demonstrate biological questions recently addressed using logic-based models and point to potential advances in model formalisms and training procedures that promise to enhance the utility of logic-based methods for studying the relationship between environmental inputs and phenotypic or signaling state outputs of complex signaling networks. PMID:20225868

  4. A measurement-based performability model for a multiprocessor system

    NASA Technical Reports Server (NTRS)

    Ilsueh, M. C.; Iyer, Ravi K.; Trivedi, K. S.

    1987-01-01

    A measurement-based performability model based on real error-data collected on a multiprocessor system is described. Model development from the raw errror-data to the estimation of cumulative reward is described. Both normal and failure behavior of the system are characterized. The measured data show that the holding times in key operational and failure states are not simple exponential and that semi-Markov process is necessary to model the system behavior. A reward function, based on the service rate and the error rate in each state, is then defined in order to estimate the performability of the system and to depict the cost of different failure types and recovery procedures.

  5. The Behavioral Economics of Choice and Interval Timing

    PubMed Central

    Jozefowiez, J.; Staddon, J. E. R.; Cerutti, D. T.

    2009-01-01

    We propose a simple behavioral economic model (BEM) describing how reinforcement and interval timing interact. The model assumes a Weber-law-compliant logarithmic representation of time. Associated with each represented time value are the payoffs that have been obtained for each possible response. At a given real time, the response with the highest payoff is emitted. The model accounts for a wide range of data from procedures such as simple bisection, metacognition in animals, economic effects in free-operant psychophysical procedures and paradoxical choice in double-bisection procedures. Although it assumes logarithmic time representation, it can also account for data from the time-left procedure usually cited in support of linear time representation. It encounters some difficulties in complex free-operant choice procedures, such as concurrent mixed fixed-interval schedules as well as some of the data on double bisection, that may involve additional processes. Overall, BEM provides a theoretical framework for understanding how reinforcement and interval timing work together to determine choice between temporally differentiated reinforcers. PMID:19618985

  6. Procedure for estimating orbital debris risks

    NASA Technical Reports Server (NTRS)

    Crafts, J. L.; Lindberg, J. P.

    1985-01-01

    A procedure for estimating the potential orbital debris risk to the world's populace from payloads or spent stages left in orbit on future missions is presented. This approach provides a consistent, but simple, procedure to assess the risk due to random reentry with an adequate accuracy level for making programmatic decisions on planned low Earth orbit missions.

  7. Simple Reshaping of the Breast in Massive Weight Loss Patients: Promising Preliminary Results.

    PubMed

    Ikander, Peder; Gad, Dorte; Gunnarsson, Gudjon Leifur; Boljanovic, Slaven; Salzberg, Andrew; Sørensen, Jens Ahm; Thomsen, Jørn Bo

    2017-02-01

    The challenging breast reshaping after massive weight loss (MWL) has been increasingly performed as the number of bariatric surgery procedures increase worldwide. The breasts often appear wide, lateralized, and deflated, with significant ptosis. The aim of this article is to share our initial experience using the lower pole subglandular advancement mastoplasty (LOPOSAM) technique to reshape the breasts in MWL patients and to elaborate the technical details and simplicity of the method in the attached video. We performed 30 LOPOSAM procedures in 15 MWL women aged 24 to 63 years from February to September 2015. We used a wise pattern mark-up and a superior based pedicle for the relocation of the nipple areola complex. The key step for the autoaugmentation was an inferior and central mound based parabola-shaped flap, which was placed in a subglandular pocket to reshape the breast and lift the inframammary crease. The median operation time for the LOPOSAM procedure was 81 minutes (range, 35-160 minutes) by 2 surgeons. The median weight loss was 64 kg (range, 45-103) and 22 body mass index units (range, 16-33) per patient. The median follow-up was 240 days (range, 105 Powered by Editorial Manager and ProduXion Manager from Aries Systems Corporation to 345). The surgical goal was achieved in all cases. Four complications occurred in 3 patients, 1 major, a hematoma-requiring surgery and 3 minor wound dehiscence. The self-reported patient satisfaction was high, 13 were very satisfied with the result, 1 satisfied, and 1 less satisfied. The LOPOSAM technique is quick and simple to perform, and the preliminary results are promising. However, a longer follow-up is needed to confirm this.

  8. Optical efficiency of solar concentrators by a reverse optical path method.

    PubMed

    Parretta, A; Antonini, A; Milan, E; Stefancich, M; Martinelli, G; Armani, M

    2008-09-15

    A method for the optical characterization of a solar concentrator, based on the reverse illumination by a Lambertian source and measurement of intensity of light projected on a far screen, has been developed. It is shown that the projected light intensity is simply correlated to the angle-resolved efficiency of a concentrator, conventionally obtained by a direct illumination procedure. The method has been applied by simulating simple reflective nonimaging and Fresnel lens concentrators.

  9. Finite-element grid improvement by minimization of stiffness matrix trace

    NASA Technical Reports Server (NTRS)

    Kittur, Madan G.; Huston, Ronald L.; Oswald, Fred B.

    1989-01-01

    A new and simple method of finite-element grid improvement is presented. The objective is to improve the accuracy of the analysis. The procedure is based on a minimization of the trace of the stiffness matrix. For a broad class of problems this minimization is seen to be equivalent to minimizing the potential energy. The method is illustrated with the classical tapered bar problem examined earlier by Prager and Masur. Identical results are obtained.

  10. Finite-element grid improvement by minimization of stiffness matrix trace

    NASA Technical Reports Server (NTRS)

    Kittur, Madan G.; Huston, Ronald L.; Oswald, Fred B.

    1987-01-01

    A new and simple method of finite-element grid improvement is presented. The objective is to improve the accuracy of the analysis. The procedure is based on a minimization of the trace of the stiffness matrix. For a broad class of problems this minimization is seen to be equivalent to minimizing the potential energy. The method is illustrated with the classical tapered bar problem examined earlier by Prager and Masur. Identical results are obtained.

  11. Proposal of simple and novel method of capacity fading analysis using pseudo-reference electrode in lithium ion cells: Application to solvent-free lithium ion polymer batteries

    NASA Astrophysics Data System (ADS)

    Shono, Kumi; Kobayashi, Takeshi; Tabuchi, Masato; Ohno, Yasutaka; Miyashiro, Hajime; Kobayashi, Yo

    2014-02-01

    We propose a simple procedure for introducing a pseudo-reference electrode (PRE) to lithium ion batteries using isometric lithium metal placed between the cathode and anode, and we successfully obtained the cathode and anode voltage profiles, individual interfacial impedances, and the misalignment of the operation range between the cathode and anode after cycle operation. The proposed procedure is applicable to lithium ion battery systems using a solid electrolyte to prepare two cells with a lithium counter electrode. We determined the capacity decrease of a solvent-free lithium ion polymer battery consisting of a LiNi1/3Mn1/3Co1/3O2 (NMC), a polyether-based solid polymer electrolyte (SPE), and a graphite (Gr) with the proposed PRE over 1000 cycles. The capacity retention of the [Gr|SPE|NMC] cell reached 50% at the 1000th cycle upon the optimization of cell preparation, and we found that the main factor of the capacity decrease was the continuous irreversible loss of active lithium at the graphite anode, not the oxidation of the SPE. Our findings suggest that we should reconsider combining a polyether-based SPE with a conventionally used 4 V class cathode and a graphite anode to develop an innovative, safe, and low-cost battery for the expected large lithium ion battery systems for stationary use.

  12. Simple Apparatus for Measuring the Critical Properties of Gases

    ERIC Educational Resources Information Center

    Donaldson, G. B.

    1973-01-01

    Describes the construction and operational procedures of a simple setup which enables undergraduate students to conduct experiments on critical phenomena in gases. Indicates that the experimental features are proved comparable to those of the Reamer and Sage apparatus. (CC)

  13. Asymptotic formulae for likelihood-based tests of new physics

    NASA Astrophysics Data System (ADS)

    Cowan, Glen; Cranmer, Kyle; Gross, Eilam; Vitells, Ofer

    2011-02-01

    We describe likelihood-based statistical tests for use in high energy physics for the discovery of new phenomena and for construction of confidence intervals on model parameters. We focus on the properties of the test procedures that allow one to account for systematic uncertainties. Explicit formulae for the asymptotic distributions of test statistics are derived using results of Wilks and Wald. We motivate and justify the use of a representative data set, called the "Asimov data set", which provides a simple method to obtain the median experimental sensitivity of a search or measurement as well as fluctuations about this expectation.

  14. A simple procedure for construction of the orthonormal basis vectors of irreducible representations of O(5) in the OT (3) ⊗ON (2) basis

    NASA Astrophysics Data System (ADS)

    Pan, Feng; Ding, Xiaoxue; Launey, Kristina D.; Draayer, J. P.

    2018-06-01

    A simple and effective algebraic isospin projection procedure for constructing orthonormal basis vectors of irreducible representations of O (5) ⊃OT (3) ⊗ON (2) from those in the canonical O (5) ⊃ SUΛ (2) ⊗ SUI (2) basis is outlined. The expansion coefficients are components of null space vectors of the projection matrix with four nonzero elements in each row in general. Explicit formulae for evaluating OT (3)-reduced matrix elements of O (5) generators are derived.

  15. An automated approach to the design of decision tree classifiers

    NASA Technical Reports Server (NTRS)

    Argentiero, P.; Chin, R.; Beaudet, P.

    1982-01-01

    An automated technique is presented for designing effective decision tree classifiers predicated only on a priori class statistics. The procedure relies on linear feature extractions and Bayes table look-up decision rules. Associated error matrices are computed and utilized to provide an optimal design of the decision tree at each so-called 'node'. A by-product of this procedure is a simple algorithm for computing the global probability of correct classification assuming the statistical independence of the decision rules. Attention is given to a more precise definition of decision tree classification, the mathematical details on the technique for automated decision tree design, and an example of a simple application of the procedure using class statistics acquired from an actual Landsat scene.

  16. Estimation of descriptive statistics for multiply censored water quality data

    USGS Publications Warehouse

    Helsel, Dennis R.; Cohn, Timothy A.

    1988-01-01

    This paper extends the work of Gilliom and Helsel (1986) on procedures for estimating descriptive statistics of water quality data that contain “less than” observations. Previously, procedures were evaluated when only one detection limit was present. Here we investigate the performance of estimators for data that have multiple detection limits. Probability plotting and maximum likelihood methods perform substantially better than simple substitution procedures now commonly in use. Therefore simple substitution procedures (e.g., substitution of the detection limit) should be avoided. Probability plotting methods are more robust than maximum likelihood methods to misspecification of the parent distribution and their use should be encouraged in the typical situation where the parent distribution is unknown. When utilized correctly, less than values frequently contain nearly as much information for estimating population moments and quantiles as would the same observations had the detection limit been below them.

  17. The MAM rodent model of schizophrenia

    PubMed Central

    Lodge, Daniel J.

    2013-01-01

    Rodent models of human disease are essential to obtain a better understanding of disease pathology, the mechanism of action underlying conventional treatments, as well as for the generation of novel therapeutic approaches. There are a number of rodent models of schizophrenia based on either genetic manipulations, acute or sub-chronic drug administration, or developmental disturbances. The prenatal methylazoxymethanol acetate (MAM) rodent model is a developmental disruption model gaining increased attention because it displays a number of histological, neurophysiological and behavioral deficits analogous to those observed in schizophrenia patients. This unit describes the procedures required to safely induce the MAM phenotype in rats. In addition, we describe a simple behavioral procedure, amphetamine-induced hyper-locomotion, which can be utilized to verify the MAM phenotype. PMID:23559309

  18. A novel method for fabrication of continuous-relief optical elements

    NASA Astrophysics Data System (ADS)

    Guo, Xiaowei; Du, Jinglei; Chen, Mingyong; Ma, Yanqin; Zhu, Jianhua; Peng, Qinjun; Guo, Yongkang; Du, Chunlei

    2005-08-01

    A novel method for the fabrication of continuous micro-optical components is presented in this paper. It employs a computer controlled spatial-light-modulator (SLM) as a switchable projection mask and silver-halide sensitized gelatin (SHSG) as recording material. By etching SHSG with enzyme solution, the micro-optical components with relief modulation can be generated through special processing procedures. The principles of digital SLM-based lithography and enzyme etching SHSG are discussed in detail, and microlens arrays, micro axicon-lens arrays and gratings with good profile were achieved. This method is simple, cheap and the aberration in processing procedures can be in-situ corrected in the step of designing mask, so it is a practical method to fabricate continuous profile for low-volume production.

  19. A fast bottom-up algorithm for computing the cut sets of noncoherent fault trees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corynen, G.C.

    1987-11-01

    An efficient procedure for finding the cut sets of large fault trees has been developed. Designed to address coherent or noncoherent systems, dependent events, shared or common-cause events, the method - called SHORTCUT - is based on a fast algorithm for transforming a noncoherent tree into a quasi-coherent tree (COHERE), and on a new algorithm for reducing cut sets (SUBSET). To assure sufficient clarity and precision, the procedure is discussed in the language of simple sets, which is also developed in this report. Although the new method has not yet been fully implemented on the computer, we report theoretical worst-casemore » estimates of its computational complexity. 12 refs., 10 figs.« less

  20. On the possibility (or lack thereof) of agreement between experiment and computation of flows over wings at moderate Reynolds number.

    PubMed

    Tank, J; Smith, L; Spedding, G R

    2017-02-06

    The flight of many birds and bats, and their robotic counterparts, occurs over a range of chord-based Reynolds numbers from 1 × 10 4 to 1.5 × 10 5 . It is precisely over this range where the aerodynamics of simple, rigid, fixed wings becomes extraordinarily sensitive to small changes in geometry and the environment, with two sets of consequences. The first is that practical lifting devices at this scale will likely not be simple, rigid, fixed wings. The second is that it becomes non-trivial to make baseline comparisons for experiment and computation, when either one can be wrong. Here we examine one ostensibly simple case of the NACA 0012 aerofoil and make careful comparison between the technical literature, and new experiments and computations. The agreement (or lack thereof) will establish one or more baseline results and some sensitivities around them. The idea is that the diagnostic procedures will help to guide comparisons and predictions in subsequent more complex cases.

  1. A fast and simple spectrofluorometric method for the determination of alendronate sodium in pharmaceuticals

    PubMed Central

    Ezzati Nazhad Dolatabadi, Jafar; Hamishehkar, Hamed; de la Guardia, Miguel; Valizadeh, Hadi

    2014-01-01

    Introduction: Alendronate sodium enhances bone formation and increases osteoblast proliferation and maturation and leads to the inhibition of osteoblast apoptosis. Therefore, a rapid and simple spectrofluorometric method has been developed and validated for the quantitative determination of it. Methods: The procedure is based on the reaction of primary amino group of alendronate with o-phthalaldehyde (OPA) in sodium hydroxide solution. Results: The calibration graph was linear over the concentration range of 0.0-2.4 μM and limit of detection and limit of quantification of the method was 8.89 and 29 nanomolar, respectively. The enthalpy and entropy of the reaction between alendronate sodium and OPA showed that the reaction is endothermic and entropy favored (ΔH = 154.08 kJ/mol; ΔS = 567.36 J/mol K) which indicates that OPA interaction with alendronate is increased at elevated temperature. Conclusion: This simple method can be used as a practical technique for the analysis of alendronate in various samples. PMID:24790897

  2. On the possibility (or lack thereof) of agreement between experiment and computation of flows over wings at moderate Reynolds number

    PubMed Central

    Tank, J.; Smith, L.

    2017-01-01

    The flight of many birds and bats, and their robotic counterparts, occurs over a range of chord-based Reynolds numbers from 1 × 104 to 1.5 × 105. It is precisely over this range where the aerodynamics of simple, rigid, fixed wings becomes extraordinarily sensitive to small changes in geometry and the environment, with two sets of consequences. The first is that practical lifting devices at this scale will likely not be simple, rigid, fixed wings. The second is that it becomes non-trivial to make baseline comparisons for experiment and computation, when either one can be wrong. Here we examine one ostensibly simple case of the NACA 0012 aerofoil and make careful comparison between the technical literature, and new experiments and computations. The agreement (or lack thereof) will establish one or more baseline results and some sensitivities around them. The idea is that the diagnostic procedures will help to guide comparisons and predictions in subsequent more complex cases. PMID:28163869

  3. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    PubMed

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (p<0.001), but the distance of that was so small (mean, 0.47 mm) that it did not cause any problem clinically. Although further improvement might be needed, such as screw specification, the closed reduction and internal fixation method has many advantages: short operative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  4. Development of virtual environments for training skills and reducing errors in laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Tendick, Frank; Downes, Michael S.; Cavusoglu, Murat C.; Gantert, Walter A.; Way, Lawrence W.

    1998-06-01

    In every surgical procedure there are key steps and skills that, if performed incorrectly, can lead to complications. In conjunction with efforts, based on task and error analysis, in the Videoscopic Training Center at UCSF to identify these key elements in laparoscopic surgical procedures, the authors are developing virtual environments and modeling methods to train the elements. Laparoscopic surgery is particularly demanding of the surgeon's spatial skills, requiring the ability to create 3D mental models and plans while viewing a 2D image. For example, operating a laparoscope with the objective lens angled from the scope axis is a skill that some surgeons have difficulty mastering, even after using the instrument in many procedures. Virtual environments are a promising medium for teaching spatial skills. A kinematically accurate model of an angled laparoscope in an environment of simple targets is being tested in courses for novice and experienced surgeons. Errors in surgery are often due to a misinterpretation of local anatomy compounded with inadequate procedural knowledge. Methods to avoid bile duct injuries in cholecystectomy are being integrated into a deformable environment consisting of the liver, gallbladder, and biliary tree. Novel deformable tissue modeling algorithms based on finite element methods will be used to improve the response of the anatomical models.

  5. Electronic test and calibration circuits, a compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A wide variety of simple test calibration circuits are compiled for the engineer and laboratory technician. The majority of circuits were found inexpensive to assemble. Testing electronic devices and components, instrument and system test, calibration and reference circuits, and simple test procedures are presented.

  6. Stereo matching and view interpolation based on image domain triangulation.

    PubMed

    Fickel, Guilherme Pinto; Jung, Claudio R; Malzbender, Tom; Samadani, Ramin; Culbertson, Bruce

    2013-09-01

    This paper presents a new approach for stereo matching and view interpolation problems based on triangular tessellations suitable for a linear array of rectified cameras. The domain of the reference image is initially partitioned into triangular regions using edge and scale information, aiming to place vertices along image edges and increase the number of triangles in textured regions. A region-based matching algorithm is then used to find an initial disparity for each triangle, and a refinement stage is applied to change the disparity at the vertices of the triangles, generating a piecewise linear disparity map. A simple post-processing procedure is applied to connect triangles with similar disparities generating a full 3D mesh related to each camera (view), which are used to generate new synthesized views along the linear camera array. With the proposed framework, view interpolation reduces to the trivial task of rendering polygonal meshes, which can be done very fast, particularly when GPUs are employed. Furthermore, the generated views are hole-free, unlike most point-based view interpolation schemes that require some kind of post-processing procedures to fill holes.

  7. An Edge-Based Method for the Incompressible Navier-Stokes Equations on Polygonal Meshes

    NASA Astrophysics Data System (ADS)

    Wright, Jeffrey A.; Smith, Richard W.

    2001-05-01

    A pressure-based method is presented for discretizing the unsteady incompressible Navier-Stokes equations using hybrid unstructured meshes. The edge-based data structure and assembly procedure adopted lead naturally to a strictly conservative discretization, which is valid for meshes composed of n-sided polygons. Particular attention is given to the construction of a pressure-velocity coupling procedure which is supported by edge data, resulting in a relatively simple numerical method that is consistent with the boundary and initial conditions required by the incompressible Navier-Stokes equations. Edge formulas are presented for assembling the momentum equations, which are based on an upwind-biased linear reconstruction of the velocity field. Similar formulas are presented for assembling the pressure equation. The method is demonstrated to be second-order accurate in space and time for two Navier-Stokes problems admitting an exact solution. Results for several other well-known problems are also presented, including lid-driven cavity flow, impulsively started cylinder flow, and unsteady vortex shedding from a circular cylinder. Although the method is by construction minimalist, it is shown to be accurate and robust for the problems considered.

  8. A simple agar plate preparation for effective transfer of Ureaplasma colonies onto nitrocellulose membranes for colony immunoblotting.

    PubMed

    Zimmerman, Carl-Ulrich R; Stiedl, Thomas; Spergser, Joachim; Rosengarten, Renate

    2014-09-01

    A simple method for preparing agar plates is presented, which allows an efficient transfer of Ureaplasma colonies to nitrocellulose membranes for subsequent immunological detection. This simple and reproducible procedure was used to demonstrate antigenic variation in the phase-variable mba-locus of Ureaplasma parvum serovar 3. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Co-occurence of florid cemento-osseous dysplasia and simple bone cyst: a case report.

    PubMed

    Rao, Kumuda Arvind; Shetty, Shishir Ram; Babu, Subhas G; Castelino, Renita Lorina

    2011-01-01

    The purpose of this report is to present a rare case of co-occurrence of florid cemento-osseous dysplasia with simple bone cyst in a middle aged Asian woman. Most of the reported cases are isolated cases of simple bone cyst or florid cemento-osseous dysplasia, but co-occurrence of these two entities is extremely rare. The authors report a 41 year old female patient with co-occurrence of mandibular florid cemento-osseous dysplasia with simple bone cyst. A thorough clinical and radiological examination was carried out. It was diagnosed mandibular cyst with possible co-occurrence of florid cemento-osseous dysplasia. Surgical exploration of the multilocular lesion was applied. Since, the patient was symptomatic at the time of presentation utmost caution was taken during the surgical procedure as florid cemento-osseous dysplasia is associated with hypo-vascularity of the affected bone. Based on histopathological, as well as supporting clinico-radiological findings a confirmative diagnosis of florid cemento-osseous dysplasia co-occurring with simple bone cyst was made. Patient was followed-up for a period of six months and was reported to be asymptomatic. Timely diagnosis and well planned treatment is important to obtain a good prognosis when a rare co-occurrence of two or more bone lesions affects the jaws.

  10. Evaluation of Oral and Maxillofacial Surgery Residents' Operative Skills: Feasibility and Engagement Study Using SIMPL Software for a Mobile Phone.

    PubMed

    Kaban, Leonard B; Cappetta, Alyssa; George, Brian C; Lahey, Edward T; Bohnen, Jordan D; Troulis, Maria J

    2017-10-01

    There are no universally accepted tools to evaluate operative skills of surgical residents in a timely fashion. The purpose of this study was to determine the feasibility of using a smartphone application, SIMPL (System for Improving and Measuring Procedural Learning), developed by a multi-institutional research collaborative, to achieve a high rate of timely operative evaluations and resident communication and to collect performance data. The authors hypothesized that these goals would be achieved because the process is convenient and efficient. This was a prospective feasibility and engagement study using SIMPL to evaluate residents' operative skills. SIMPL requires the attending surgeon to answer 3 multiple-choice questions: 1) What level of help (Zwisch Scale) was required by the trainee? 2) What was the level of performance? 3) How complex was the case? The evaluator also can dictate a narrative. The sample was composed of 3 faculty members and 3 volunteer senior residents. Predictor variables were the surgeons, trainees, and procedures performed. Outcome variables included number and percentage of procedures performed by faculty-and-resident pairs assessed, time required to complete assessments, time lapsed to submission, percentage of assessments with narratives, and residents' response rates. From March through June 2016, 151 procedures were performed in the operating room by the faculty-and-resident teams. There were 107 assessments submitted (71%). Resident response (self-assessment) to faculty evaluations was 81%. Recorded time to complete assessments (n = 75 of 107) was shorter than 2 minutes. The time lapsed to submission was shorter than 72 hours (100%). Dictations were submitted for 35 evaluations (33%). Data for the type of help, performance, and complexity of cases were collected for each resident. SIMPL facilitates timely intraoperative evaluations of surgical skills, engagement by faculty and residents, and collection of detailed procedural data. Additional prospective trials to assess this tool further are planned. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. QUEST - A Bayesian adaptive psychometric method

    NASA Technical Reports Server (NTRS)

    Watson, A. B.; Pelli, D. G.

    1983-01-01

    An adaptive psychometric procedure that places each trial at the current most probable Bayesian estimate of threshold is described. The procedure takes advantage of the common finding that the human psychometric function is invariant in form when expressed as a function of log intensity. The procedure is simple, fast, and efficient, and may be easily implemented on any computer.

  12. [Cryopreservation of mouse embryos in ethylene glycol-based solutions: a search for the optimal and simple protocols].

    PubMed

    Luo, Ming-Jiu; Liu, Na; Miao, De-Qiang; Lan, Guo-Cheng; Suo-Feng; Chang, Zhong-Le; Tan, Jing-He

    2005-09-01

    Although ethylene glycol (EG) has been widely used for embryo cryopreservation in domestic animals, few attempts were made to use this molecule to freeze mouse and human embryos. In the few studies that used EG for slow-freezing of mouse and human embryos, complicated protocols for human embryos were used, and the protocols need to be simplified. Besides, freezing mouse morula with EG as a cryoprotectant has not been reported. In this paper, we studied the effects of embryo stages, EG concentration, duration and procedure of equilibration, sucrose supplementation and EG removal after thawing on the development of thawed mouse embryos, using the simple freezing and thawing procedures for bovine embryos. The blastulation and hatching rates (81.92% +/- 2.24% and 68.56% +/- 2.43%, respectively) of the thawed late compact morulae were significantly (P < 0.05) higher than those of embryos frozen-thawed at other stages. When mouse late compact morulae were frozen with different concentrations of EG, the highest rates of blastocyst formation and hatching were obtained with 1.8mol/L EG. The blastulation rate was significantly higher when late morulae were equilibrated in 1.8 mol/L EG for 10 min prior to freezing than when they were equilibrated for 30 min, and the hatching rate of embryos exposed to EG for 10 min was significantly higher than that of embryos exposed for 20 and 30 min. Both rates of blastocyst formation and hatching obtained with two-step equilibration were higher (P < 0.05) than with one-step equilibration in 1.8 mol/L EG. Addition of sucrose to the EG-based solution had no beneficial effects. On the contrary, an increased sucrose level (0.4 mol/L) in the solution impaired the development of the frozen-thawed embryos. In contrast, addition of 0.1 mol/L sucrose to the propylene glycol (PG)-based solution significantly improved the development of the frozen-thawed embryos. Elimination of the cryoprotectant after thawing did not improve the development of the thawed embryos. The cell numbers were less (P < 0.05) in blastocysts developed from the thawed morulae than in the in vivo derived ones. In summary, embryo stage, EG concentration, duration and procedure of equilibration and sucrose supplementation had marked effects on development of the thawed mouse embryos, and a protocol for cryopreservation of mouse embryos is recommended in which the late morulae are frozen in 1.8 mol/L EG using the simple freezing and thawing procedures of bovine embryos after a two-step equilibration and the embryos can be cultured or transferred without EG removal after thawing.

  13. A simple and rapid microplate assay for glycoprotein-processing glycosidases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, M.S.; Zwolshen, J.H.; Harry, B.S.

    1989-08-15

    A simple and convenient microplate assay for glycosidases involved in the glycoprotein-processing reactions is described. The assay is based on specific binding of high-mannose-type oligosaccharide substrates to concanavalin A-Sepharose, while monosaccharides liberated by enzymatic hydrolysis do not bind to concanavalin A-Sepharose. By the use of radiolabeled substrates (( 3H)glucose for glucosidases and (3H)mannose for mannosidases), the radioactivity in the liberated monosaccharides can be determined as a measure of the enzymatic activity. This principle was employed earlier for developing assays for glycosidases previously reported. These authors have reported the separation of substrate from the product by concanavalin A-Sepharose column chromatography. Thismore » procedure is handicapped by the fact that it cannot be used for a large number of samples and is time consuming. We have simplified this procedure and adapted it to the use of a microplate (96-well plate). This would help in processing a large number of samples in a short time. In this report we show that the assay is comparable to the column assay previously reported. It is linear with time and enzyme concentration and shows expected kinetics with castanospermine, a known inhibitor of alpha-glucosidase I.« less

  14. Median of patient results as a tool for assessment of analytical stability.

    PubMed

    Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft; Sölétormos, György

    2015-06-15

    In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable analytical bias based on biological variation. Seventy five percent of the twenty analytes achieved on two COBASs INTEGRA 800 instruments performed in accordance with the optimum and with the desirable specifications for bias. Patient results applied in analytical quality performance control procedures are the most reliable sources of material as they represent the genuine substance of the measurements and therefore circumvent the problems associated with non-commutable materials in external assessment. Patient medians in the monthly monitoring of analytical stability in laboratory medicine are an inexpensive, simple and reliable tool to monitor the steadiness of the analytical practice. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Identification and Correction of Additive and Multiplicative Spatial Biases in Experimental High-Throughput Screening.

    PubMed

    Mazoure, Bogdan; Caraus, Iurie; Nadon, Robert; Makarenkov, Vladimir

    2018-06-01

    Data generated by high-throughput screening (HTS) technologies are prone to spatial bias. Traditionally, bias correction methods used in HTS assume either a simple additive or, more recently, a simple multiplicative spatial bias model. These models do not, however, always provide an accurate correction of measurements in wells located at the intersection of rows and columns affected by spatial bias. The measurements in these wells depend on the nature of interaction between the involved biases. Here, we propose two novel additive and two novel multiplicative spatial bias models accounting for different types of bias interactions. We describe a statistical procedure that allows for detecting and removing different types of additive and multiplicative spatial biases from multiwell plates. We show how this procedure can be applied by analyzing data generated by the four HTS technologies (homogeneous, microorganism, cell-based, and gene expression HTS), the three high-content screening (HCS) technologies (area, intensity, and cell-count HCS), and the only small-molecule microarray technology available in the ChemBank small-molecule screening database. The proposed methods are included in the AssayCorrector program, implemented in R, and available on CRAN.

  16. Polydopamine-Functionalized CA-(PCL-ran-PLA) Nanoparticles for Target Delivery of Docetaxel and Chemo-photothermal Therapy of Breast Cancer

    PubMed Central

    Kong, Na; Deng, Mei; Sun, Xiu-Na; Chen, Yi-Ding; Sui, Xin-Bing

    2018-01-01

    Current limitations of cancer therapy include the lack of effective strategy for target delivery of chemotherapeutic drugs, and the difficulty of achieving significant efficacy by single treatment. Herein, we reported a synergistic chemo-photothermal strategy based on aptamer (Apt)-polydopamine (pD) functionalized CA-(PCL-ran-PLA) nanoparticles (NPs) for effective delivery of docetaxel (DTX) and enhanced therapeutic effect. The developed DTX-loaded Apt-pD-CA-(PCL-ran-PLA) NPs achieved promising advantages, such as (i) improved drug loading content (LC) and encapsulation efficiency (EE) initiated by star-shaped copolymer CA-(PCL-ran-PLA); (ii) effective target delivery of drugs to tumor sites by incorporating AS1411 aptamers; (iii) significant therapeutic efficacy caused by synergistic chemo-photothermal treatment. In addition, the pD coating strategy with simple procedures could address the contradiction between targeting modification and maintaining formerly excellent bio-properties. Therefore, with excellent bio-properties and simple preparation procedures, the DTX-loaded Apt-pD-CA-(PCL-ran-PLA) NPs effectively increased the local drug concentration in tumor sites, minimized side effects, and significantly eliminated tumors, indicating the promising application of these NPs for cancer therapy. PMID:29527167

  17. Stochastic output error vibration-based damage detection and assessment in structures under earthquake excitation

    NASA Astrophysics Data System (ADS)

    Sakellariou, J. S.; Fassois, S. D.

    2006-11-01

    A stochastic output error (OE) vibration-based methodology for damage detection and assessment (localization and quantification) in structures under earthquake excitation is introduced. The methodology is intended for assessing the state of a structure following potential damage occurrence by exploiting vibration signal measurements produced by low-level earthquake excitations. It is based upon (a) stochastic OE model identification, (b) statistical hypothesis testing procedures for damage detection, and (c) a geometric method (GM) for damage assessment. The methodology's advantages include the effective use of the non-stationary and limited duration earthquake excitation, the handling of stochastic uncertainties, the tackling of the damage localization and quantification subproblems, the use of "small" size, simple and partial (in both the spatial and frequency bandwidth senses) identified OE-type models, and the use of a minimal number of measured vibration signals. Its feasibility and effectiveness are assessed via Monte Carlo experiments employing a simple simulation model of a 6 storey building. It is demonstrated that damage levels of 5% and 20% reduction in a storey's stiffness characteristics may be properly detected and assessed using noise-corrupted vibration signals.

  18. Mechanical Resonance of a Plastic Strip.

    ERIC Educational Resources Information Center

    Ayers, R. Dean

    1981-01-01

    Presents an experiment to illustrate mechanical resonance designed for use in lower division laboratories. The apparatus and procedure have been kept simple. The basic experiment yields measurements of amplitude versus driving frequency, but a fairly simple elaboration allows for measurements of phase lag as well. (Author/SK)

  19. Understanding Exponential Growth: As Simple as a Drop in a Bucket.

    ERIC Educational Resources Information Center

    Goldberg, Fred; Shuman, James

    1984-01-01

    Provides procedures for a simple laboratory activity on exponential growth and its characteristic doubling time. The equipment needed consists of a large plastic bucket, an eyedropper, a stopwatch, an assortment of containers and graduated cylinders, and a supply of water. (JN)

  20. Simple Experiments on Magnetism and Electricity...from Edison.

    ERIC Educational Resources Information Center

    Schultz, Robert F.

    Background information, lists of materials needed and procedures used are provided for 16 simple experiments on electricity and magnetism. These experiments are organized into sections dealing with: (1) Edison's carbon experiments (building a galvanometer, investigating the variable conductivity of carbon, and examining the carbon transmitter…

  1. Simple and complex mental subtraction: strategy choice and speed-of-processing differences in younger and older adults.

    PubMed

    Geary, D C; Frensch, P A; Wiley, J G

    1993-06-01

    Thirty-six younger adults (10 male, 26 female; ages 18 to 38 years) and 36 older adults (14 male, 22 female; ages 61 to 80 years) completed simple and complex paper-and-pencil subtraction tests and solved a series of simple and complex computer-presented subtraction problems. For the computer task, strategies and solution times were recorded on a trial-by-trial basis. Older Ss used a developmentally more mature mix of problem-solving strategies to solve both simple and complex subtraction problems. Analyses of component scores derived from the solution times suggest that the older Ss are slower at number encoding and number production but faster at executing the borrow procedure. In contrast, groups did not appear to differ in the speed of subtraction fact retrieval. Results from a computational simulation are consistent with the interpretation that older adults' advantage for strategy choices and for the speed of executing the borrow procedure might result from more practice solving subtraction problems.

  2. The Fibrin slide assay for detecting urokinase activity in human fetal kidney cells

    NASA Technical Reports Server (NTRS)

    Sedor, K.

    1985-01-01

    The Fibrin Slide Technique of Hau C. Kwaan and Tage Astrup is discussed. This relatively simple assay involves two steps: the formation of an artificial clot and then the addition of an enzyme (UKOKINASE) to dissolve the clot. The actual dissolving away of the clot is detected by the appearance of holes (lysis zones) in the stained clot. The procedure of Kwaan and Astrup is repeated, along with modifications and suggestions for improvements based on experience with the technique.

  3. Assessment of Growth Problems in Adolescents

    PubMed Central

    Baker, F.W.

    1986-01-01

    Investigation of an adolescent growth problem consists of taking an adequate history and doing a complete physical examination. This procedure, along with a calculation of bone age and height/weight age, will allow family physicians to decide on the cause of the growth variance in most patients. Relatively simple studies can be done in the family physician's office to delineate the major causes of growth problems; the majority will be unrelated to the endocrine system. Further studies may be needed in a hospital-based setting. PMID:21267222

  4. Nanostructured manganese oxide/carbon nanotubes, graphene and graphene oxide as water-oxidizing composites in artificial photosynthesis.

    PubMed

    Najafpour, Mohammad Mahdi; Rahimi, Fahime; Fathollahzadeh, Maryam; Haghighi, Behzad; Hołyńska, Małgorzata; Tomo, Tatsuya; Allakhverdiev, Suleyman I

    2014-07-28

    Herein, we report on nano-sized Mn oxide/carbon nanotubes, graphene and graphene oxide as water-oxidizing compounds in artificial photosynthesis. The composites are synthesized by different and simple procedures and characterized by a number of methods. The water-oxidizing activities of these composites are also considered in the presence of cerium(IV) ammonium nitrate. Some composites are efficient Mn-based catalysts with TOF (mmol O2 per mol Mn per second) ~ 2.6.

  5. BPERM version 3.0: A 2-D wakepotential/impedance code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barts, T.; Chou, W.

    1996-10-01

    BPERM 3.0 is an improved version of a previous release. The main purpose of this version is to make it more user friendly. Following a simple 1-2-3 procedure, one obtains both text and graphical output of the wakepotential and impedance for a given geometry. The calculation is based on a boundary perturbation method, which is significantly faster than numerical simulations. It is accurate when the discontinuities are small. In particular, it works well for tapered structures. 5 refs., 3 figs.

  6. Proportional plus integral MIMO controller for regulation and tracking with anti-wind-up features

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puleston, P.F.; Mantz, R.J.

    1993-11-01

    A proportional plus integral matrix control structure for MIMO systems is proposed. Based on a standard optimal control structure with integral action, it permits a greater degree of independence of the design and tuning of the regulating and tracking features, without considerably increasing the controller complexity. Fast recovery from load disturbances is achieved, while large overshoots associated with set-point changes and reset wind-up problems can be reduced. A simple effective procedure for practical tuning is introduced.

  7. Microwave-Assisted Condensation Reactions of Acetophenone Derivatives and Activated Methylene Compounds with Aldehydes Catalyzed by Boric Acid under Solvent-Free Conditions.

    PubMed

    Brun, Elodie; Safer, Abdelmounaim; Carreaux, François; Bourahla, Khadidja; L'helgoua'ch, Jean-Martial; Bazureau, Jean-Pierre; Villalgordo, Jose Manuel

    2015-06-23

    We here disclosed a new protocol for the condensation of acetophenone derivatives and active methylene compounds with aldehydes in the presence of boric acid under microwave conditions. Implementation of the reaction is simple, healthy and environmentally friendly owing to the use of a non-toxic catalyst coupled to a solvent-free procedure. A large variety of known or novel compounds have thus been prepared, including with substrates bearing acid or base-sensitive functional groups.

  8. Virtually Instantaneous, Room-temperature [11C]-Cyanation Using Biaryl Phosphine Pd(0) Complexes

    PubMed Central

    Lee, Hong Geun; Milner, Phillip J.; Placzek, Michael S.; Buchwald, Stephen L.; Hooker, Jacob M.

    2015-01-01

    A new radiosynthetic protocol for the preparation of [11C]aryl nitriles has been developed. This process is based on the direct reaction of in situ prepared L•Pd(Ar)X complexes (L=biaryl phosphine) with [11C]HCN. The strategy is operationally simple, exhibits a remarkably wide substrate scope with short reaction times, and demonstrates superior reactivity compared to previously reported systems. With this procedure, a variety of [11C]nitrile-containing pharmaceuticals were prepared with high radiochemical efficiency. PMID:25565277

  9. A multiple-objective optimal exploration strategy

    USGS Publications Warehouse

    Christakos, G.; Olea, R.A.

    1988-01-01

    Exploration for natural resources is accomplished through partial sampling of extensive domains. Such imperfect knowledge is subject to sampling error. Complex systems of equations resulting from modelling based on the theory of correlated random fields are reduced to simple analytical expressions providing global indices of estimation variance. The indices are utilized by multiple objective decision criteria to find the best sampling strategies. The approach is not limited by geometric nature of the sampling, covers a wide range in spatial continuity and leads to a step-by-step procedure. ?? 1988.

  10. Simple and Sensitive Molecularly Imprinted Polymer - Mn-Doped ZnS Quantum Dots Based Fluorescence Probe for Cocaine and Metabolites Determination in Urine.

    PubMed

    Chantada-Vázquez, María Pilar; Sánchez-González, Juan; Peña-Vázquez, Elena; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio

    2016-03-01

    A new molecularly imprinted polymer (MIP)-based fluorescent artificial receptor has been prepared by anchoring a selective MIP for cocaine (COC) on the surface of polyethylene glycol (PEG) modified Mn-doped ZnS quantum dots (QDs). The prepared material combines the high selectivity attributed to MIPs and the sensitive fluorescent property of the Mn-doped ZnS QDs. Simple and low cost methods have therefore been optimized for assessing cocaine abuse in urine by monitoring the fluorescence quenching when the template (COC) and also metabolites from COC [benzoylecgonine (BZE) and ecgonine methyl ester (EME)] are present. Fluorescence quenching was not observed when performing experiments with other drugs of abuse (and their metabolites) or when using nonimprinted polymer (NIP)-coated QDs. Under optimized operating conditions (1.5 mL of 200 mg L(-1) MIP-coated QDs solution, pH 5.5, and 15 min before fluorescence scanning) two analytical methods were developed/validated. One of the procedures (direct method) consisted of urine sample 1:20 dilution before fluorescence measurements. The method has been found to be fast, precise, and accurate, but the standard addition technique for performing the analysis was required because of the existence of matrix effect. The second procedure performed a solid phase extraction (SPE) first, avoiding matrix effect and allowing external calibration. The limits of detection of the methods were 0.076 mg L(-1) (direct method) and 0.0042 mg L(-1) (SPE based method), which are lower than the cutoff values for confirmative conclusions regarding cocaine abuse.

  11. New coherent laser communication detection scheme based on channel-switching method.

    PubMed

    Liu, Fuchuan; Sun, Jianfeng; Ma, Xiaoping; Hou, Peipei; Cai, Guangyu; Sun, Zhiwei; Lu, Zhiyong; Liu, Liren

    2015-04-01

    A new coherent laser communication detection scheme based on the channel-switching method is proposed. The detection front end of this scheme comprises a 90° optical hybrid and two balanced photodetectors which outputs the in-phase (I) channel and quadrature-phase (Q) channel signal current, respectively. With this method, the ultrahigh speed analog/digital transform of the signal of the I or Q channel is not required. The phase error between the signal and local lasers is obtained by simple analog circuit. Using the phase error signal, the signals of the I/Q channel are switched alternately. The principle of this detection scheme is presented. Moreover, the comparison of the sensitivity of this scheme with that of homodyne detection with an optical phase-locked loop is discussed. An experimental setup was constructed to verify the proposed detection scheme. The offline processing procedure and results are presented. This scheme could be realized through simple structure and has potential applications in cost-effective high-speed laser communication.

  12. Verifying the botanical authenticity of commercial tannins through sugars and simple phenols profiles.

    PubMed

    Malacarne, Mario; Nardin, Tiziana; Bertoldi, Daniela; Nicolini, Giorgio; Larcher, Roberto

    2016-09-01

    Commercial tannins from several botanical sources and with different chemical and technological characteristics are used in the food and winemaking industries. Different ways to check their botanical authenticity have been studied in the last few years, through investigation of different analytical parameters. This work proposes a new, effective approach based on the quantification of 6 carbohydrates, 7 polyalcohols, and 55 phenols. 87 tannins from 12 different botanical sources were analysed following a very simple sample preparation procedure. Using Forward Stepwise Discriminant Analysis, 3 statistical models were created based on sugars content, phenols concentration and combination of the two classes of compounds for the 8 most abundant categories (i.e. oak, grape seed, grape skin, gall, chestnut, quebracho, tea and acacia). The last approach provided good results in attributing tannins to the correct botanical origin. Validation, repeated 3 times on subsets of 10% of samples, confirmed the reliability of this model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Indirect glyphosate detection based on ninhydrin reaction and surface-enhanced Raman scattering spectroscopy

    NASA Astrophysics Data System (ADS)

    Xu, Meng-Lei; Gao, Yu; Li, Yali; Li, Xueliang; Zhang, Huanjie; Han, Xiao Xia; Zhao, Bing; Su, Liang

    2018-05-01

    Glyphosate is one of the most commonly-used and non-selective herbicides in agriculture, which may directly pollute the environment and threaten human health. A simple and effective approach to assessment of its damage to the natural environment is thus quite necessary. However, traditional chromatography-based detection methods usually suffer from complex pretreatment procedures. Herein, we propose a simple and sensitive method for the determination of glyphosate by combining ninhydrin reaction and surface-enhanced Raman scattering (SERS) spectroscopy. The product (purple color dye, PD) of the ninhydrin reaction is found to SERS-active and directly correlate with the glyphosate concentration. The limit of detection of the proposed method for glyphosate is as low as 1.43 × 10- 8 mol·L- 1 with a relatively wider linear concentration range (1.0 × 10- 7-1.0 × 10- 4 mol·L- 1), which demonstrates its great potential in rapid, highly sensitive concentration determination of glyphosate in practical applications for safety assessment of food and environment.

  14. Simulation model calibration and validation : phase II : development of implementation handbook and short course.

    DOT National Transportation Integrated Search

    2006-01-01

    A previous study developed a procedure for microscopic simulation model calibration and validation and evaluated the procedure via two relatively simple case studies using three microscopic simulation models. Results showed that default parameters we...

  15. A simple model for studying rotation errors of gimbal mount axes in laser tracking system based on spherical mirror as a reflection unit

    NASA Astrophysics Data System (ADS)

    Song, Huixu; Shi, Zhaoyao; Chen, Hongfang; Sun, Yanqiang

    2018-01-01

    This paper presents a novel experimental approach and a simple model for verifying that spherical mirror of laser tracking system could lessen the effect of rotation errors of gimbal mount axes based on relative motion thinking. Enough material and evidence are provided to support that this simple model could replace complex optical system in laser tracking system. This experimental approach and model interchange the kinematic relationship between spherical mirror and gimbal mount axes in laser tracking system. Being fixed stably, gimbal mount axes' rotation error motions are replaced by spatial micro-displacements of spherical mirror. These motions are simulated by driving spherical mirror along the optical axis and vertical direction with the use of precision positioning platform. The effect on the laser ranging measurement accuracy of displacement caused by the rotation errors of gimbal mount axes could be recorded according to the outcome of laser interferometer. The experimental results show that laser ranging measurement error caused by the rotation errors is less than 0.1 μm if radial error motion and axial error motion are under 10 μm. The method based on relative motion thinking not only simplifies the experimental procedure but also achieves that spherical mirror owns the ability to reduce the effect of rotation errors of gimbal mount axes in laser tracking system.

  16. Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.

    PubMed

    Smith, R F; Mather, H M; Ellard, G A

    1998-02-01

    The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.

  17. Robotic general surgery experience: a gradual progress from simple to more complex procedures.

    PubMed

    Al-Naami, M; Anjum, M N; Aldohayan, A; Al-Khayal, K; Alkharji, H

    2013-12-01

    Robotic surgery was introduced at our institution in 2003, and we used a progressive approach advancing from simple to more complex procedures. A retrospective chart review. Cases included totalled 129. Set-up and operative times have improved over time and with experience. Conversion rates to standard laparoscopic or open techniques were 4.7% and 1.6%, respectively. Intraoperative complications (6.2%), blood loss and hospital stay were directly proportional to complexity. There were no mortalities and the postoperative complication rate (13.2%) was within accepted norms. Our findings suggest that robot technology is presently most useful in cases tailored toward its advantages, i.e. those confined to a single space, those that require performance of complex tasks, and re-do procedures. Copyright © 2013 John Wiley & Sons, Ltd.

  18. The Mine Locomotive Wireless Network Strategy Based on Successive Interference Cancellation

    PubMed Central

    Wu, Liaoyuan; Han, Jianghong; Wei, Xing; Shi, Lei; Ding, Xu

    2015-01-01

    We consider a wireless network strategy based on successive interference cancellation (SIC) for mine locomotives. We firstly build the original mathematical model for the strategy which is a non-convex model. Then, we examine this model intensively, and figure out that there are certain regulations embedded in it. Based on these findings, we are able to reformulate the model into a new form and design a simple algorithm which can assign each locomotive with a proper transmitting scheme during the whole schedule procedure. Simulation results show that the outcomes obtained through this algorithm are improved by around 50% compared with those that do not apply the SIC technique. PMID:26569240

  19. An investigation of several factors involved in a finite difference procedure for analyzing the transonic flow about harmonically oscillating airfoils and wings

    NASA Technical Reports Server (NTRS)

    Ehlers, F. E.; Sebastian, J. D.; Weatherill, W. H.

    1979-01-01

    Analytical and empirical studies of a finite difference method for the solution of the transonic flow about harmonically oscillating wings and airfoils are presented. The procedure is based on separating the velocity potential into steady and unsteady parts and linearizing the resulting unsteady equations for small disturbances. Since sinusoidal motion is assumed, the unsteady equation is independent of time. Three finite difference investigations are discussed including a new operator for mesh points with supersonic flow, the effects on relaxation solution convergence of adding a viscosity term to the original differential equation, and an alternate and relatively simple downstream boundary condition. A method is developed which uses a finite difference procedure over a limited inner region and an approximate analytical procedure for the remaining outer region. Two investigations concerned with three-dimensional flow are presented. The first is the development of an oblique coordinate system for swept and tapered wings. The second derives the additional terms required to make row relaxation solutions converge when mixed flow is present. A finite span flutter analysis procedure is described using the two-dimensional unsteady transonic program with a full three-dimensional steady velocity potential.

  20. Efficient etching-free transfer of high quality, large-area CVD grown graphene onto polyvinyl alcohol films

    NASA Astrophysics Data System (ADS)

    Marta, Bogdan; Leordean, Cosmin; Istvan, Todor; Botiz, Ioan; Astilean, Simion

    2016-02-01

    Graphene transfer is a procedure of paramount importance for the production of graphene-based electronic devices. The transfer procedure can affect the electronic properties of the transferred graphene and can be detrimental for possible applications both due to procedure induced defects which can appear and due to scalability of the method. Hence, it is important to investigate new transfer methods for graphene that are less time consuming and show great promise. In the present study we propose an efficient, etching-free transfer method that consists in applying a thin polyvinyl alcohol layer on top of the CVD grown graphene on Cu and then peeling-off the graphene onto the polyvinyl alcohol film. We investigate the quality of the transferred graphene before and after the transfer, using Raman spectroscopy and imaging as well as optical and atomic force microscopy techniques. This simple transfer method is scalable and can lead to complete transfer of graphene onto flexible and transparent polymer support films without affecting the quality of the graphene during the transfer procedure.

  1. Registration of planar bioluminescence to magnetic resonance and x-ray computed tomography images as a platform for the development of bioluminescence tomography reconstruction algorithms.

    PubMed

    Beattie, Bradley J; Klose, Alexander D; Le, Carl H; Longo, Valerie A; Dobrenkov, Konstantine; Vider, Jelena; Koutcher, Jason A; Blasberg, Ronald G

    2009-01-01

    The procedures we propose make possible the mapping of two-dimensional (2-D) bioluminescence image (BLI) data onto a skin surface derived from a three-dimensional (3-D) anatomical modality [magnetic resonance (MR) or computed tomography (CT)] dataset. This mapping allows anatomical information to be incorporated into bioluminescence tomography (BLT) reconstruction procedures and, when applied using sources visible to both optical and anatomical modalities, can be used to evaluate the accuracy of those reconstructions. Our procedures, based on immobilization of the animal and a priori determined fixed projective transforms, should be more robust and accurate than previously described efforts, which rely on a poorly constrained retrospectively determined warping of the 3-D anatomical information. Experiments conducted to measure the accuracy of the proposed registration procedure found it to have a mean error of 0.36+/-0.23 mm. Additional experiments highlight some of the confounds that are often overlooked in the BLT reconstruction process, and for two of these confounds, simple corrections are proposed.

  2. Palladium nanoparticles formed on titanium silicate ETS-10.

    PubMed

    Lin, Christopher C H; Danaie, Mohsen; Mitlin, David; Kuznicki, Steven M

    2011-03-01

    We report that surface templated and supported palladium nanoparticles self assemble on ETS-10 type molecular sieve surfaces by simple exchange and activation procedures in the absence of a reductant. This procedure is similar to the one previously reported for silver nanoparticle self assembly on ETS-10. We observed a bimodal distribution with particle sizes ranging from 2-5 and 15-30 nm. This simple, economical method generates high concentrations (approximately 12 wt% of total composite) of uniform, metallic palladium nanoparticles that are multiply twinned and thermally stable making them potentially unique for advanced catalytic and electronic applications.

  3. A comparison of methods for teaching receptive language to toddlers with autism.

    PubMed

    Vedora, Joseph; Grandelski, Katrina

    2015-01-01

    The use of a simple-conditional discrimination training procedure, in which stimuli are initially taught in isolation with no other comparison stimuli, is common in early intensive behavioral intervention programs. Researchers have suggested that this procedure may encourage the development of faulty stimulus control during training. The current study replicated previous work that compared the simple-conditional and the conditional-only methods to teach receptive labeling of pictures to young children with autism spectrum disorder. Both methods were effective, but the conditional-only method required fewer sessions to mastery. © Society for the Experimental Analysis of Behavior.

  4. Comparison of two PCR-based methods and automated DNA sequencing for prop-1 genotyping in Ames dwarf mice.

    PubMed

    Gerstner, Arpad; DeFord, James H; Papaconstantinou, John

    2003-07-25

    Ames dwarfism is caused by a homozygous single nucleotide mutation in the pituitary specific prop-1 gene, resulting in combined pituitary hormone deficiency, reduced growth and extended lifespan. Thus, these mice serve as an important model system for endocrinological, aging and longevity studies. Because the phenotype of wild type and heterozygous mice is undistinguishable, it is imperative for successful breeding to accurately genotype these animals. Here we report a novel, yet simple, approach for prop-1 genotyping using PCR-based allele-specific amplification (PCR-ASA). We also compare this method to other potential genotyping techniques, i.e. PCR-based restriction fragment length polymorphism analysis (PCR-RFLP) and fluorescence automated DNA sequencing. We demonstrate that the single-step PCR-ASA has several advantages over the classical PCR-RFLP because the procedure is simple, less expensive and rapid. To further increase the specificity and sensitivity of the PCR-ASA, we introduced a single-base mismatch at the 3' penultimate position of the mutant primer. Our results also reveal that the fluorescence automated DNA sequencing has limitations for detecting a single nucleotide polymorphism in the prop-1 gene, particularly in heterozygotes.

  5. Efficient Levenberg-Marquardt minimization of the maximum likelihood estimator for Poisson deviates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurence, T; Chromy, B

    2009-11-10

    Histograms of counted events are Poisson distributed, but are typically fitted without justification using nonlinear least squares fitting. The more appropriate maximum likelihood estimator (MLE) for Poisson distributed data is seldom used. We extend the use of the Levenberg-Marquardt algorithm commonly used for nonlinear least squares minimization for use with the MLE for Poisson distributed data. In so doing, we remove any excuse for not using this more appropriate MLE. We demonstrate the use of the algorithm and the superior performance of the MLE using simulations and experiments in the context of fluorescence lifetime imaging. Scientists commonly form histograms ofmore » counted events from their data, and extract parameters by fitting to a specified model. Assuming that the probability of occurrence for each bin is small, event counts in the histogram bins will be distributed according to the Poisson distribution. We develop here an efficient algorithm for fitting event counting histograms using the maximum likelihood estimator (MLE) for Poisson distributed data, rather than the non-linear least squares measure. This algorithm is a simple extension of the common Levenberg-Marquardt (L-M) algorithm, is simple to implement, quick and robust. Fitting using a least squares measure is most common, but it is the maximum likelihood estimator only for Gaussian-distributed data. Non-linear least squares methods may be applied to event counting histograms in cases where the number of events is very large, so that the Poisson distribution is well approximated by a Gaussian. However, it is not easy to satisfy this criterion in practice - which requires a large number of events. It has been well-known for years that least squares procedures lead to biased results when applied to Poisson-distributed data; a recent paper providing extensive characterization of these biases in exponential fitting is given. The more appropriate measure based on the maximum likelihood estimator (MLE) for the Poisson distribution is also well known, but has not become generally used. This is primarily because, in contrast to non-linear least squares fitting, there has been no quick, robust, and general fitting method. In the field of fluorescence lifetime spectroscopy and imaging, there have been some efforts to use this estimator through minimization routines such as Nelder-Mead optimization, exhaustive line searches, and Gauss-Newton minimization. Minimization based on specific one- or multi-exponential models has been used to obtain quick results, but this procedure does not allow the incorporation of the instrument response, and is not generally applicable to models found in other fields. Methods for using the MLE for Poisson-distributed data have been published by the wider spectroscopic community, including iterative minimization schemes based on Gauss-Newton minimization. The slow acceptance of these procedures for fitting event counting histograms may also be explained by the use of the ubiquitous, fast Levenberg-Marquardt (L-M) fitting procedure for fitting non-linear models using least squares fitting (simple searches obtain {approx}10000 references - this doesn't include those who use it, but don't know they are using it). The benefits of L-M include a seamless transition between Gauss-Newton minimization and downward gradient minimization through the use of a regularization parameter. This transition is desirable because Gauss-Newton methods converge quickly, but only within a limited domain of convergence; on the other hand the downward gradient methods have a much wider domain of convergence, but converge extremely slowly nearer the minimum. L-M has the advantages of both procedures: relative insensitivity to initial parameters and rapid convergence. Scientists, when wanting an answer quickly, will fit data using L-M, get an answer, and move on. Only those that are aware of the bias issues will bother to fit using the more appropriate MLE for Poisson deviates. However, since there is a simple, analytical formula for the appropriate MLE measure for Poisson deviates, it is inexcusable that least squares estimators are used almost exclusively when fitting event counting histograms. There have been ways found to use successive non-linear least squares fitting to obtain similarly unbiased results, but this procedure is justified by simulation, must be re-tested when conditions change significantly, and requires two successive fits. There is a great need for a fitting routine for the MLE estimator for Poisson deviates that has convergence domains and rates comparable to the non-linear least squares L-M fitting. We show in this report that a simple way to achieve that goal is to use the L-M fitting procedure not to minimize the least squares measure, but the MLE for Poisson deviates.« less

  6. Expansion of Tabulated Scattering Matrices in Generalized Spherical Functions

    NASA Technical Reports Server (NTRS)

    Mishchenko, Michael I.; Geogdzhayev, Igor V.; Yang, Ping

    2016-01-01

    An efficient way to solve the vector radiative transfer equation for plane-parallel turbid media is to Fourier-decompose it in azimuth. This methodology is typically based on the analytical computation of the Fourier components of the phase matrix and is predicated on the knowledge of the coefficients appearing in the expansion of the normalized scattering matrix in generalized spherical functions. Quite often the expansion coefficients have to be determined from tabulated values of the scattering matrix obtained from measurements or calculated by solving the Maxwell equations. In such cases one needs an efficient and accurate computer procedure converting a tabulated scattering matrix into the corresponding set of expansion coefficients. This short communication summarizes the theoretical basis of this procedure and serves as the user guide to a simple public-domain FORTRAN program.

  7. Effectiveness of a five-step method for teaching clinical skills to students in a dental college in India.

    PubMed

    Virdi, Mandeep S; Sood, Meenakshi

    2011-11-01

    This study conducted at the PDM Dental College and Research Institute, Haryana, India, had the purpose of developing a teaching method based upon a five-step method for teaching clinical skills to students proposed by the American College of Surgeons. This five-step teaching method was used to place fissure sealants as an initial procedure by dental students in clinics. The sealant retention was used as an objective evaluation of the skill learnt by the students. The sealant retention was 92 percent at six- and twelve-month evaluations and 90 percent at the eighteen-month evaluation. These results indicate that simple methods can be devised for teaching clinical skills and achieve high success rates in clinical procedures requiring multiple steps.

  8. Aerodynamic design of the contoured wind-tunnel liner for the NASA supercritical, laminar-flow-control, swept-wing experiment

    NASA Technical Reports Server (NTRS)

    Newman, P. A.; Anderson, E. C.; Peterson, J. B., Jr.

    1984-01-01

    An overview is presented of the entire procedure developed for the aerodynamic design of the contoured wind tunnel liner for the NASA supercritical, laminar flow control (LFC), swept wing experiment. This numerical design procedure is based upon the simple idea of streamlining and incorporates several transonic and boundary layer analysis codes. The liner, presently installed in the Langley 8 Foot Transonic Pressure Tunnel, is about 54 ft long and extends from within the existing contraction cone, through the test section, and into the diffuser. LFC model testing has begun and preliminary results indicate that the liner is performing as intended. The liner design results presented in this paper, however, are examples of the calculated requirements and the hardware implementation of them.

  9. State of charge estimation in Ni-MH rechargeable batteries

    NASA Astrophysics Data System (ADS)

    Milocco, R. H.; Castro, B. E.

    In this work we estimate the state of charge (SOC) of Ni-MH rechargeable batteries using the Kalman filter based on a simplified electrochemical model. First, we derive the complete electrochemical model of the battery which includes diffusional processes and kinetic reactions in both Ni and MH electrodes. The full model is further reduced in a cascade of two parts, a linear time invariant dynamical sub-model followed by a static nonlinearity. Both parts are identified using the current and potential measured at the terminals of the battery with a simple 1-D minimization procedure. The inverse of the static nonlinearity together with a Kalman filter provide the SOC estimation as a linear estimation problem. Experimental results with commercial batteries are provided to illustrate the estimation procedure and to show the performance.

  10. A Geometry Based Infra-structure for Computational Analysis and Design

    NASA Technical Reports Server (NTRS)

    Haimes, Robert

    1997-01-01

    The computational steps traditionally taken for most engineering analysis (CFD, structural analysis, and etc.) are: Surface Generation - usually by employing a CAD system; Grid Generation - preparing the volume for the simulation; Flow Solver - producing the results at the specified operational point; and Post-processing Visualization - interactively attempting to understand the results For structural analysis, integrated systems can be obtained from a number of commercial vendors. For CFD, these steps have worked well in the past for simple steady-state simulations at the expense of much user interaction. The data was transmitted between phases via files. Specifically the problems with this procedure are: (1) File based. Information flows from one step to the next via data files with formats specified for that procedure. (2) 'Good' Geometry. A bottleneck in getting results from a solver is the construction of proper geometry to be fed to the grid generator. With 'good' geometry a grid can be constructed in tens of minutes (even with a complex configuration) using unstructured techniques. (3) One-Way communication. All information travels on from one phase to the next. Until this process can be automated, more complex problems such as multi-disciplinary analysis or using the above procedure for design becomes prohibitive.

  11. Recycling Perovskite Solar Cells To Avoid Lead Waste.

    PubMed

    Binek, Andreas; Petrus, Michiel L; Huber, Niklas; Bristow, Helen; Hu, Yinghong; Bein, Thomas; Docampo, Pablo

    2016-05-25

    Methylammonium lead iodide (MAPbI3) perovskite based solar cells have recently emerged as a serious competitor for large scale and low-cost photovoltaic technologies. However, since these solar cells contain toxic lead, a sustainable procedure for handling the cells after their operational lifetime is required to prevent exposure of the environment to lead and to comply with international electronic waste disposal regulations. Herein, we report a procedure to remove every layer of the solar cells separately, which gives the possibility to selectively isolate the different materials. Besides isolating the toxic lead iodide in high yield, we show that the PbI2 can be reused for the preparation of new solar cells with comparable performance and in this way avoid lead waste. Furthermore, we show that the most expensive part of the solar cell, the conductive glass (FTO), can be reused several times without any reduction in the performance of the devices. With our simple recycling procedure, we address both the risk of contamination and the waste disposal of perovskite based solar cells while further reducing the cost of the system. This brings perovskite solar cells one step closer to their introduction into commercial systems.

  12. An evaluation of risk estimation procedures for mixtures of carcinogens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hwang, J.S.; Chen, J.J.

    1999-12-01

    The estimation of health risks from exposure to a mixture of chemical carcinogens is generally based on the combination of information from several available single compound studies. The current practice of directly summing the upper bound risk estimates of individual carcinogenic components as an upper bound on the total risk of a mixture is known to be generally too conservative. Gaylor and Chen (1996, Risk Analysis) proposed a simple procedure to compute an upper bound on the total risk using only the upper confidence limits and central risk estimates of individual carcinogens. The Gaylor-Chen procedure was derived based on anmore » underlying assumption of the normality for the distributions of individual risk estimates. IN this paper the authors evaluated the Gaylor-Chen approach in terms the coverages of the upper confidence limits on the true risks of individual carcinogens. In general, if the coverage probabilities for the individual carcinogens are all approximately equal to the nominal level, then the Gaylor-Chen approach should perform well. However, the Gaylor-Chen approach can be conservative or anti-conservative if some of all individual upper confidence limit estimates are conservative or anti-conservative.« less

  13. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    ERIC Educational Resources Information Center

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  14. Solving Simple Kinetics without Integrals

    ERIC Educational Resources Information Center

    de la Pen~a, Lisandro Herna´ndez

    2016-01-01

    The solution of simple kinetic equations is analyzed without referencing any topic from differential equations or integral calculus. Guided by the physical meaning of the rate equation, a systematic procedure is used to generate an approximate solution that converges uniformly to the exact solution in the case of zero, first, and second order…

  15. Prediction of Transport Properties of Permeants through Polymer Films. A Simple Gravimetric Experiment.

    ERIC Educational Resources Information Center

    Britton, L. N.; And Others

    1988-01-01

    Considers the applicability of the simple emersion/weight-gain method for predicting diffusion coefficients, solubilities, and permeation rates of chemicals in polymers that do not undergo physical and chemical deterioration. Presents the theoretical background, procedures and typical results related to this activity. (CW)

  16. SIMPLE METHOD FOR THE EXTRACTION OF PHOTOPIGMENTS AND MYCOSPORINE-LIKE AMINO ACIDS (MAAS) FROM SYMBIODINIUM SPP.

    EPA Science Inventory

    Numerous extraction methods have been developed and used in the quantitation of both photopigments and mycosporine amino acids (MAAs) found in Symbiodinium sp. and zooanthellate metazoans. We have development of a simple, mild extraction procedure using methanol, which when coupl...

  17. A simple visual ethanol biosensor based on alcohol oxidase immobilized onto polyaniline film for halal verification of fermented beverage samples.

    PubMed

    Kuswandi, Bambang; Irmawati, Titi; Hidayat, Moch Amrun; Jayus; Ahmad, Musa

    2014-01-27

    A simple visual ethanol biosensor based on alcohol oxidase (AOX) immobilised onto polyaniline (PANI) film for halal verification of fermented beverage samples is described. This biosensor responds to ethanol via a colour change from green to blue, due to the enzymatic reaction of ethanol that produces acetaldehyde and hydrogen peroxide, when the latter oxidizes the PANI film. The procedure to obtain this biosensor consists of the immobilization of AOX onto PANI film by adsorption. For the immobilisation, an AOX solution is deposited on the PANI film and left at room temperature until dried (30 min). The biosensor was constructed as a dip stick for visual and simple use. The colour changes of the films have been scanned and analysed using image analysis software (i.e., ImageJ) to study the characteristics of the biosensor's response toward ethanol. The biosensor has a linear response in an ethanol concentration range of 0.01%-0.8%, with a correlation coefficient (r) of 0.996. The limit detection of the biosensor was 0.001%, with reproducibility (RSD) of 1.6% and a life time up to seven weeks when stored at 4 °C. The biosensor provides accurate results for ethanol determination in fermented drinks and was in good agreement with the standard method (gas chromatography) results. Thus, the biosensor could be used as a simple visual method for ethanol determination in fermented beverage samples that can be useful for Muslim community for halal verification.

  18. Mixed-order phase transition in a minimal, diffusion-based spin model.

    PubMed

    Fronczak, Agata; Fronczak, Piotr

    2016-07-01

    In this paper we exactly solve, within the grand canonical ensemble, a minimal spin model with the hybrid phase transition. We call the model diffusion based because its Hamiltonian can be recovered from a simple dynamic procedure, which can be seen as an equilibrium statistical mechanics representation of a biased random walk. We outline the derivation of the phase diagram of the model, in which the triple point has the hallmarks of the hybrid transition: discontinuity in the average magnetization and algebraically diverging susceptibilities. At this point, two second-order transition curves meet in equilibrium with the first-order curve, resulting in a prototypical mixed-order behavior.

  19. Finding text in color images

    NASA Astrophysics Data System (ADS)

    Zhou, Jiangying; Lopresti, Daniel P.; Tasdizen, Tolga

    1998-04-01

    In this paper, we consider the problem of locating and extracting text from WWW images. A previous algorithm based on color clustering and connected components analysis works well as long as the color of each character is relatively uniform and the typography is fairly simple. It breaks down quickly, however, when these assumptions are violated. In this paper, we describe more robust techniques for dealing with this challenging problem. We present an improved color clustering algorithm that measures similarity based on both RGB and spatial proximity. Layout analysis is also incorporated to handle more complex typography. THese changes significantly enhance the performance of our text detection procedure.

  20. Simultaneous determination of dextromethorphan HBr and bromhexine HCl in tablets by first-derivative spectrophotometry.

    PubMed

    Tantishaiyakul, V; Poeaknapo, C; Sribun, P; Sirisuppanon, K

    1998-06-01

    A rapid, simple and direct assay procedure based on first-derivative spectrophotometry, using a zero-crossing and peak-to-base measurement at 234 and 324 nm, respectively, has been developed for the specific determination of dextromethorphan HBr and bromhexine HCl in tablets. Calibration graphs were linear with the correlation coefficients of 0.9999 for both analytes. The limit of detections were 0.033 and 0.103 microgram ml-1 for dextromethorphan HBr and bromhexine HCl, respectively. A HPLC method has been developed as the reference method. The results obtained by the first-derivative spectrophotometry were in good agreement with those found by the HPLC method.

  1. The research of .NET framework based on delegate of the LCE

    NASA Astrophysics Data System (ADS)

    Chen, Yi-peng

    2011-10-01

    Programmers realize LCE Enterprise services provided by NET framework when they develop applied VC# programming design language with component technology facing objects Lots of basic codes used to be compiled in the traditional programming design. However, nowadays this can be done just by adding corresponding character at class, interface, method, assembly with simple declarative program. This paper mainly expatiates the mechanism to realize LCE event services with delegate mode in C#. It also introduces the procedure of applying event class, event publisher, subscriber and client in LCE technology. It analyses the technology points of LCE based on delegate mode with popular language and practicing cases.

  2. Promoting Spontaneous Second Harmonic Generation through Organogelation.

    PubMed

    Marco, A Belén; Aparicio, Fátima; Faour, Lara; Iliopoulos, Konstantinos; Morille, Yohann; Allain, Magali; Franco, Santiago; Andreu, Raquel; Sahraoui, Bouchta; Gindre, Denis; Canevet, David; Sallé, Marc

    2016-07-27

    An organogelator based on the Disperse Red nonlinear optical chromophore was synthesized according to a simple and efficient three-step procedure. The supramolecular gel organization leads to xerogels which display a spontaneous second harmonic generation (SHG) response without any need for preprocessing, and this SHG activity appears to be stable over several months. These findings, based on an intrinsic structural approach, are supported by favorable intermolecular supramolecular interactions, which promote a locally non-centrosymmetric NLO-active organization. This is in sharp contrast with most materials designed for SHG purposes, which generally require the use of expensive or heavy-to-handle external techniques for managing the dipoles' alignment.

  3. Modeling procedures for handling qualities evaluation of flexible aircraft

    NASA Technical Reports Server (NTRS)

    Govindaraj, K. S.; Eulrich, B. J.; Chalk, C. R.

    1981-01-01

    This paper presents simplified modeling procedures to evaluate the impact of flexible modes and the unsteady aerodynamic effects on the handling qualities of Supersonic Cruise Aircraft (SCR). The modeling procedures involve obtaining reduced order transfer function models of SCR vehicles, including the important flexible mode responses and unsteady aerodynamic effects, and conversion of the transfer function models to time domain equations for use in simulations. The use of the modeling procedures is illustrated by a simple example.

  4. A simple and cheap system to speed up and to control the tumescent technique procedure: the Tedde's system.

    PubMed

    Rubino, C; Marongiu, F; Manzo, M J; Tedde, G; Madonia, M; Campus, G V; Farace, F

    2014-06-01

    We have devised a low cost system to quickly infiltrate tumescent solution: we call it the "Tedde's system". This low-cost system offers an improvement in quality and quantity of the infiltration because all the procedure depends on the operators, reducing also the time of the infiltration and consequently of the whole surgical procedure. Moreover, this system can be applied to other surgical procedure that requires large infiltration volumes.

  5. Task as a Heuristic for Understanding Student Learning and Motivation.

    ERIC Educational Resources Information Center

    Blumenfeld, Phyllis C.; And Others

    1987-01-01

    Describes the cognitive characteristics and procedural "forms" associated with common school learning tasks. Illustrates how variations in these can affect student motivation and learning. Concludes that simple task content and unvaried procedures tend to result in limited thinkers and alienated workers. (JDH)

  6. DEVELOPMENT OF A PROTOCOL FOR TESTING EFFECTS OF TOXIC SUBSTANCES ON PLANTS

    EPA Science Inventory

    This study was designed to devise a rapid, simple, reproducible bioassay procedure to determine effects of so-called 'toxic substances in the environment' on vegetation and provide a standardized procedure for evaluation and comparison of effects of diverse compounds. Eight diffe...

  7. Simple procedures for enrichment of chlorinated aromatic pollutants from fat, water and milk for subsequent analysis by high-resolution methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egestad, B.; Curstedt, T.; Sjoevall, J.

    1982-01-01

    Procedures for enrichment of non-volatile chlorinated aromatic pollutants from fat, water and milk are described. /sup 14/C-DDT was used as a model compound in recovery experiments. A several thousand-fold enrichment of DDT added to butter was achieved by two consecutive straight-phase chromatographies on Lipidex 5000. Trace amounts of DDT in liter volumes of water could be quantitatively extracted by rapid filtration through 2 ml beds of Lipidex 1000. A batch extraction procedure permitted enrichment of DDT from milk after addition of n-pentylamine, methanol and water. DDT could then be eluted from the gel with retention of more than 90% ofmore » the lipids. A reversed-phase system with Lipidex 5000 could be used for separation of TCDD from DDT and PCBs. The liquid-gel chromatographic procedures are simple and suitable for clean-up of samples prior to application of high-resolution methods. 5 tables.« less

  8. Phase-unwrapping algorithm by a rounding-least-squares approach

    NASA Astrophysics Data System (ADS)

    Juarez-Salazar, Rigoberto; Robledo-Sanchez, Carlos; Guerrero-Sanchez, Fermin

    2014-02-01

    A simple and efficient phase-unwrapping algorithm based on a rounding procedure and a global least-squares minimization is proposed. Instead of processing the gradient of the wrapped phase, this algorithm operates over the gradient of the phase jumps by a robust and noniterative scheme. Thus, the residue-spreading and over-smoothing effects are reduced. The algorithm's performance is compared with four well-known phase-unwrapping methods: minimum cost network flow (MCNF), fast Fourier transform (FFT), quality-guided, and branch-cut. A computer simulation and experimental results show that the proposed algorithm reaches a high-accuracy level than the MCNF method by a low-computing time similar to the FFT phase-unwrapping method. Moreover, since the proposed algorithm is simple, fast, and user-free, it could be used in metrological interferometric and fringe-projection automatic real-time applications.

  9. Direct N-alkylation of unprotected amino acids with alcohols

    PubMed Central

    Yan, Tao; Feringa, Ben L.; Barta, Katalin

    2017-01-01

    N-alkyl amino acids find widespread application as highly valuable, renewable building blocks. However, traditional synthesis methodologies to obtain these suffer from serious limitations, providing a major challenge to develop sustainable alternatives. We report the first powerful catalytic strategy for the direct N-alkylation of unprotected α-amino acids with alcohols. This method is highly selective, produces water as the only side product leading to a simple purification procedure, and a variety of α-amino acids are mono- or di-N-alkylated, in most cases with excellent retention of optical purity. The hydrophobicity of the products is tunable, and even simple peptides are selectively alkylated. An iron-catalyzed route to mono-N-alkyl amino acids using renewable fatty alcohols is also described that represents an ideal green transformation for obtaining fully bio-based surfactants. PMID:29226249

  10. Characterization of biofilms with a fiber optic spectrometer

    NASA Astrophysics Data System (ADS)

    Krautwald, S.; Tonyali, A.; Fellerhoff, B.; Franke, Hilmar; Tamachkiarov, A.; Griebe, T.; Flemming, H. C.

    2000-12-01

    Optical sensing is one promising approach to monitor bioflims in an early stage. Generally, natural bioflims are quite inhomogeneous, therefore we start the investigation with suspensions of dead bacteria in water as a simple model for a bioflim. An experimental arrangement based on a white light fiber optic spectrometer is used for measuring the density of a thin film with a local resolution in the order of several tim. The method is applied with model biofilms. In a computer controlled procedure reflectance spectra may be recorded at different positions in the x-y plane. Scanning through thin suspension regions of bacteria between glass plates allows an estimation of the refractive index of bacteria. Taking advantage of the light collecting property of the glass substrate a simple measurement of the fluorescence with local resolution is demonstrated as well.

  11. A simple way to obtain backscattered electron images in a scanning transmission electron microscope.

    PubMed

    Tsuruta, Hiroki; Tanaka, Shigeyasu; Tanji, Takayoshi; Morita, Chiaki

    2014-08-01

    We have fabricated a simple detector for backscattered electrons (BSEs) and incorporated the detector into a scanning transmission electron microscope (STEM) sample holder. Our detector was made from a 4-mm(2) Si chip. The fabrication procedure was easy, and similar to a standard transmission electron microscopy (TEM) sample thinning process based on ion milling. A TEM grid containing particle objects was fixed to the detector with a silver paste. Observations were carried out using samples of Au and latex particles at 75 and 200 kV. Such a detector provides an easy way to obtain BSE images in an STEM. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Facile Synthesis of Porous Silicon Nanofibers by Magnesium Reduction for Application in Lithium Ion Batteries.

    PubMed

    Cho, Daehwan; Kim, Moonkyoung; Hwang, Jeonghyun; Park, Jay Hoon; Joo, Yong Lak; Jeong, Youngjin

    2015-12-01

    We report a facile fabrication of porous silicon nanofibers by a simple three-stage procedure. Polymer/silicon precursor composite nanofibers are first fabricated by electrospinning, a water-based spinning dope, which undergoes subsequent heat treatment and then reduction using magnesium to be converted into porous silicon nanofibers. The porous silicon nanofibers are coated with a graphene by using a plasma-enhanced chemical vapor deposition for use as an anode material of lithium ion batteries. The porous silicon nanofibers can be mass-produced by a simple and solvent-free method, which uses an environmental-friendly polymer solution. The graphene-coated silicon nanofibers show an improved cycling performance of a capacity retention than the pure silicon nanofibers due to the suppression of the volume change and the increase of electric conductivity by the graphene.

  13. Recognition of Simple 3D Geometrical Objects under Partial Occlusion

    NASA Astrophysics Data System (ADS)

    Barchunova, Alexandra; Sommer, Gerald

    In this paper we present a novel procedure for contour-based recognition of partially occluded three-dimensional objects. In our approach we use images of real and rendered objects whose contours have been deformed by a restricted change of the viewpoint. The preparatory part consists of contour extraction, preprocessing, local structure analysis and feature extraction. The main part deals with an extended construction and functionality of the classifier ensemble Adaptive Occlusion Classifier (AOC). It relies on a hierarchical fragmenting algorithm to perform a local structure analysis which is essential when dealing with occlusions. In the experimental part of this paper we present classification results for five classes of simple geometrical figures: prism, cylinder, half cylinder, a cube, and a bridge. We compare classification results for three classical feature extractors: Fourier descriptors, pseudo Zernike and Zernike moments.

  14. Prevalidation in pharmaceutical analysis. Part I. Fundamentals and critical discussion.

    PubMed

    Grdinić, Vladimir; Vuković, Jadranka

    2004-05-28

    A complete prevalidation, as a basic prevalidation strategy for quality control and standardization of analytical procedure was inaugurated. Fast and simple, the prevalidation methodology based on mathematical/statistical evaluation of a reduced number of experiments (N < or = 24) was elaborated and guidelines as well as algorithms were given in detail. This strategy has been produced for the pharmaceutical applications and dedicated to the preliminary evaluation of analytical methods where linear calibration model, which is very often occurred in practice, could be the most appropriate to fit experimental data. The requirements presented in this paper should therefore help the analyst to design and perform the minimum number of prevalidation experiments needed to obtain all the required information to evaluate and demonstrate the reliability of its analytical procedure. In complete prevalidation process, characterization of analytical groups, checking of two limiting groups, testing of data homogeneity, establishment of analytical functions, recognition of outliers, evaluation of limiting values and extraction of prevalidation parameters were included. Moreover, system of diagnosis for particular prevalidation step was suggested. As an illustrative example for demonstration of feasibility of prevalidation methodology, among great number of analytical procedures, Vis-spectrophotometric procedure for determination of tannins with Folin-Ciocalteu's phenol reagent was selected. Favourable metrological characteristics of this analytical procedure, as prevalidation figures of merit, recognized the metrological procedure as a valuable concept in preliminary evaluation of quality of analytical procedures.

  15. "Compacted" procedures for adults' simple addition: A review and critique of the evidence.

    PubMed

    Chen, Yalin; Campbell, Jamie I D

    2018-04-01

    We review recent empirical findings and arguments proffered as evidence that educated adults solve elementary addition problems (3 + 2, 4 + 1) using so-called compacted procedures (e.g., unconscious, automatic counting); a conclusion that could have significant pedagogical implications. We begin with the large-sample experiment reported by Uittenhove, Thevenot and Barrouillet (2016, Cognition, 146, 289-303), which tested 90 adults on the 81 single-digit addition problems from 1 + 1 to 9 + 9. They identified the 12 very-small addition problems with different operands both ≤ 4 (e.g., 4 + 3) as a distinct subgroup of problems solved by unconscious, automatic counting: These items yielded a near-perfectly linear increase in answer response time (RT) yoked to the sum of the operands. Using the data reported in the article, however, we show that there are clear violations of the sum-counting model's predictions among the very-small addition problems, and that there is no real RT boundary associated with addends ≤4. Furthermore, we show that a well-known associative retrieval model of addition facts-the network interference theory (Campbell, 1995)-predicts the results observed for these problems with high precision. We also review the other types of evidence adduced for the compacted procedure theory of simple addition and conclude that these findings are unconvincing in their own right and only distantly consistent with automatic counting. We conclude that the cumulative evidence for fast compacted procedures for adults' simple addition does not justify revision of the long-standing assumption that direct memory retrieval is ultimately the most efficient process of simple addition for nonzero problems, let alone sufficient to recommend significant changes to basic addition pedagogy.

  16. Computationally efficient stochastic optimization using multiple realizations

    NASA Astrophysics Data System (ADS)

    Bayer, P.; Bürger, C. M.; Finkel, M.

    2008-02-01

    The presented study is concerned with computationally efficient methods for solving stochastic optimization problems involving multiple equally probable realizations of uncertain parameters. A new and straightforward technique is introduced that is based on dynamically ordering the stack of realizations during the search procedure. The rationale is that a small number of critical realizations govern the output of a reliability-based objective function. By utilizing a problem, which is typical to designing a water supply well field, several variants of this "stack ordering" approach are tested. The results are statistically assessed, in terms of optimality and nominal reliability. This study demonstrates that the simple ordering of a given number of 500 realizations while applying an evolutionary search algorithm can save about half of the model runs without compromising the optimization procedure. More advanced variants of stack ordering can, if properly configured, save up to more than 97% of the computational effort that would be required if the entire number of realizations were considered. The findings herein are promising for similar problems of water management and reliability-based design in general, and particularly for non-convex problems that require heuristic search techniques.

  17. Estimating human-equivalent no observed adverse-effect levels for VOCs (volatile organic compounds) based on minimal knowledge of physiological parameters. Technical paper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Overton, J.H.; Jarabek, A.M.

    1989-01-01

    The U.S. EPA advocates the assessment of health-effects data and calculation of inhaled reference doses as benchmark values for gauging systemic toxicity to inhaled gases. The assessment often requires an inter- or intra-species dose extrapolation from no observed adverse effect level (NOAEL) exposure concentrations in animals to human equivalent NOAEL exposure concentrations. To achieve this, a dosimetric extrapolation procedure was developed based on the form or type of equations that describe the uptake and disposition of inhaled volatile organic compounds (VOCs) in physiologically-based pharmacokinetic (PB-PK) models. The procedure assumes allometric scaling of most physiological parameters and that the value ofmore » the time-integrated human arterial-blood concentration must be limited to no more than to that of experimental animals. The scaling assumption replaces the need for most parameter values and allows the derivation of a simple formula for dose extrapolation of VOCs that gives equivalent or more-conservative exposure concentrations values than those that would be obtained using a PB-PK model in which scaling was assumed.« less

  18. A conceptual weather-type classification procedure for the Philadelphia, Pennsylvania, area

    USGS Publications Warehouse

    McCabe, Gregory J.

    1990-01-01

    A simple method of weather-type classification, based on a conceptual model of pressure systems that pass through the Philadelphia, Pennsylvania, area, has been developed. The only inputs required for the procedure are daily mean wind direction and cloud cover, which are used to index the relative position of pressure systems and fronts to Philadelphia.Daily mean wind-direction and cloud-cover data recorded at Philadelphia, Pennsylvania, from January 1954 through August 1988 were used to categorize daily weather conditions. The conceptual weather types reflect changes in daily air and dew-point temperatures, and changes in monthly mean temperature and monthly and annual precipitation. The weather-type classification produced by using the conceptual model was similar to a classification produced by using a multivariate statistical classification procedure. Even though the conceptual weather types are derived from a small amount of data, they appear to account for the variability of daily weather patterns sufficiently to describe distinct weather conditions for use in environmental analyses of weather-sensitive processes.

  19. Development of electrical test procedures for qualification of spacecraft against EID. Volume 1: The CAN test and other relevant data

    NASA Technical Reports Server (NTRS)

    Wilkenfeld, J. M.; Judge, R. J. R.; Harlacher, B. L.

    1982-01-01

    A combined experimental and analytical program to develop system electrical test procedures for the qualification of spacecraft against damage produced by space-electron-induced discharges (EID) occurring on spacecraft dielectric outer surfaces is described. The data on the response of a simple satellite model, called CAN, to electron-induced discharges is presented. The experimental results were compared to predicted behavior and to the response of the CAN to electrical injection techniques simulating blowoff and arc discharges. Also included is a review of significant results from other ground tests and the P78-2 program to form a data base from which is specified those test procedures which optimally simulate the response of spacecraft to EID. The electrical and electron spraying test data were evaluated to provide a first-cut determination of the best methods for performance of electrical excitation qualification tests from the point of view of simulation fidelity.

  20. Electroless Deposition of Palladium on Macroscopic 3D-Printed Polymers with Dense Microlattice Architectures for Development of Multifunctional Composite Materials

    DOE PAGES

    Jones, Christopher G.; Mills, Bernice E.; Nishimoto, Ryan K.; ...

    2017-10-25

    A simple procedure has been developed to create palladium (Pd) films on the surface of several common polymers used in commercial fused deposition modeling (FDM) and stereolithography (SLA) based three-dimensional (3D) printing by an electroless deposition process. The procedure can be performed at room temperature, with equipment less expensive than many 3D printers, and occurs rapidly enough to achieve full coverage of the film within a few minutes. 3D substrates composed of dense logpile or cubic lattices with part sizes in the mm to cm range, and feature sizes as small as 150 μm were designed and printed using commerciallymore » available 3D printers. The deposition procedure was successfully adapted to show full coverage in the lattice substrates. As a result, the ability to design, print, and metallize highly ordered three-dimensional microscale structures could accelerate development of a range of optimized chemical and mechanical engineering systems.« less

  1. [Evaluation of mass spectrometry: MALDI-TOF MS for fast and reliable yeast identification].

    PubMed

    Relloso, María S; Nievas, Jimena; Fares Taie, Santiago; Farquharson, Victoria; Mujica, María T; Romano, Vanesa; Zarate, Mariela S; Smayevsky, Jorgelina

    2015-01-01

    The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique known as MALDI-TOF MS is a tool used for the identification of clinical pathogens by generating a protein spectrum that is unique for a given species. In this study we assessed the identification of clinical yeast isolates by MALDI-TOF MS in a university hospital from Argentina and compared two procedures for protein extraction: a rapid method and a procedure based on the manufacturer's recommendations. A short protein extraction procedure was applied in 100 isolates and the rate of correct identification at genus and species level was 98.0%. In addition, we analyzed 201 isolates, previously identified by conventional methods, using the methodology recommended by the manufacturer and there was 95.38% coincidence in the identification at species level. MALDI TOF MS showed to be a fast, simple and reliable tool for yeast identification. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Electroless Deposition of Palladium on Macroscopic 3D-Printed Polymers with Dense Microlattice Architectures for Development of Multifunctional Composite Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Christopher G.; Mills, Bernice E.; Nishimoto, Ryan K.

    A simple procedure has been developed to create palladium (Pd) films on the surface of several common polymers used in commercial fused deposition modeling (FDM) and stereolithography (SLA) based three-dimensional (3D) printing by an electroless deposition process. The procedure can be performed at room temperature, with equipment less expensive than many 3D printers, and occurs rapidly enough to achieve full coverage of the film within a few minutes. 3D substrates composed of dense logpile or cubic lattices with part sizes in the mm to cm range, and feature sizes as small as 150 μm were designed and printed using commerciallymore » available 3D printers. The deposition procedure was successfully adapted to show full coverage in the lattice substrates. As a result, the ability to design, print, and metallize highly ordered three-dimensional microscale structures could accelerate development of a range of optimized chemical and mechanical engineering systems.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, Mario E.

    An area in earthquake risk reduction that needs an urgent examination is the selection of earthquake records for nonlinear dynamic analysis of structures. An often-mentioned shortcoming from results of nonlinear dynamic analyses of structures is that these results are limited to the type of records that these analyses use as input data. This paper proposes a procedure for selecting earthquake records for nonlinear dynamic analysis of structures. This procedure uses a seismic damage index evaluated using the hysteretic energy dissipated by a Single Degree of Freedom System (SDOF) representing a multi-degree-of freedom structure responding to an earthquake record, and themore » plastic work capacity of the system at collapse. The type of structural system is considered using simple parameters. The proposed method is based on the evaluation of the damage index for a suite of earthquake records and a selected type of structural system. A set of 10 strong ground motion records is analyzed to show an application of the proposed procedure for selecting earthquake records for structural design.« less

  4. A single-step simultaneous protein staining procedure for polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis.

    PubMed

    Pal, Jayanta K; Berwal, Sunil K; Soni, Rupali N

    2012-01-01

    A simple method for staining of proteins simultaneously on sodium dodecyl sulfate (SDS) polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis is described. A 5% solution of Alta, a commercially available cosmetic preparation, is added in the upper tank buffer during electrophoresis. On completion of electrophoresis, the gel is washed in distilled water and viewed on a white light plate and a transilluminator to photograph the protein profiles. The gel is processed for western blot transfer of proteins onto a nitrocellulose membrane, and upon completion, the protein profiles on the membrane are viewed and photographed as stated above. The membrane can then be processed for immunostaining as per the standard procedure. Thus, the staining procedure using Alta is simple, rapid (without any need of destaining), and cost-effective.

  5. Toward dynamic lumbar punctures guidance based on single element synthetic tracked aperture ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.

    2017-03-01

    Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.

  6. Chip-based nanoflow high performance liquid chromatography coupled to mass spectrometry for profiling of soybean flavonoids.

    PubMed

    Chang, Yuwei; Zhao, Chunxia; Wu, Zeming; Zhou, Jia; Zhao, Sumin; Lu, Xin; Xu, Guowang

    2012-08-01

    In this work a chip-based nano HPLC coupled MS (HPLC-chip/MS) method with a simple sample preparation procedure was developed for the flavonoid profiling of soybean. The analytical properties of the method including the linearity (R(2) , 0.992-0.995), reproducibility (RSD, 1.50-7.66%), intraday precision (RSD, 1.41-5.14%) and interday precision (RSD, 2.76-16.90%) were satisfactory. Compared with the conventional HPLC/MS method, a fast extraction and analysis procedure was applied and more flavonoids were detected in a single run. Additionally, 13 flavonoids in soybean seed were identified for the first time. The method was then applied to the profiling of six varieties of soybean sowed at the same place. A clear discrimination was observed among different cultivars, three isoflavones, accounting for nearly 80% of total flavonoid contents, were found increased in the spring soybeans compared with the summer cultivars. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Improving the Crossing-SIBTEST Statistic for Detecting Non-uniform DIF.

    PubMed

    Chalmers, R Philip

    2018-06-01

    This paper demonstrates that, after applying a simple modification to Li and Stout's (Psychometrika 61(4):647-677, 1996) CSIBTEST statistic, an improved variant of the statistic could be realized. It is shown that this modified version of CSIBTEST has a more direct association with the SIBTEST statistic presented by Shealy and Stout (Psychometrika 58(2):159-194, 1993). In particular, the asymptotic sampling distributions and general interpretation of the effect size estimates are the same for SIBTEST and the new CSIBTEST. Given the more natural connection to SIBTEST, it is shown that Li and Stout's hypothesis testing approach is insufficient for CSIBTEST; thus, an improved hypothesis testing procedure is required. Based on the presented arguments, a new chi-squared-based hypothesis testing approach is proposed for the modified CSIBTEST statistic. Positive results from a modest Monte Carlo simulation study strongly suggest the original CSIBTEST procedure and randomization hypothesis testing approach should be replaced by the modified statistic and hypothesis testing method.

  8. Cryogenic Tank Structure Sizing With Structural Optimization Method

    NASA Technical Reports Server (NTRS)

    Wang, J. T.; Johnson, T. F.; Sleight, D. W.; Saether, E.

    2001-01-01

    Structural optimization methods in MSC /NASTRAN are used to size substructures and to reduce the weight of a composite sandwich cryogenic tank for future launch vehicles. Because the feasible design space of this problem is non-convex, many local minima are found. This non-convex problem is investigated in detail by conducting a series of analyses along a design line connecting two feasible designs. Strain constraint violations occur for some design points along the design line. Since MSC/NASTRAN uses gradient-based optimization procedures. it does not guarantee that the lowest weight design can be found. In this study, a simple procedure is introduced to create a new starting point based on design variable values from previous optimization analyses. Optimization analysis using this new starting point can produce a lower weight design. Detailed inputs for setting up the MSC/NASTRAN optimization analysis and final tank design results are presented in this paper. Approaches for obtaining further weight reductions are also discussed.

  9. The Effectiveness of the Component Impact Test Method for the Side Impact Injury Assessment of the Door Trim

    NASA Astrophysics Data System (ADS)

    Youn, Younghan; Koo, Jeong-Seo

    The complete evaluation of the side vehicle structure and the occupant protection is only possible by means of the full scale side impact crash test. But, auto part manufacturers such as door trim makers can not conduct the test especially when the vehicle is under the developing process. The main objective of this study is to obtain the design guidelines by a simple component level impact test. The relationship between the target absorption energy and impactor speed were examined using the energy absorbed by the door trim. Since each different vehicle type required different energy levels on the door trim. A simple impact test method was developed to estimate abdominal injury by measuring reaction force of the impactor. The reaction force will be converted to a certain level of the energy by the proposed formula. The target of absorption energy for door trim only and the impact speed of simple impactor are derived theoretically based on the conservation of energy. With calculated speed of dummy and the effective mass of abdomen, the energy allocated in the abdomen area of door trim was calculated. The impactor speed can be calculated based on the equivalent energy of door trim absorbed during the full crash test. With the proposed design procedure for the door trim by a simple impact test method was demonstrated to evaluate the abdominal injury. This paper describes a study that was conducted to determine sensitivity of several design factors for reducing abdominal injury values using the matrix of orthogonal array method. In conclusion, with theoretical considerations and empirical test data, the main objective, standardization of door trim design using the simple impact test method was established.

  10. Enzyme Activity Experiments Using a Simple Spectrophotometer

    ERIC Educational Resources Information Center

    Hurlbut, Jeffrey A.; And Others

    1977-01-01

    Experimental procedures for studying enzyme activity using a Spectronic 20 spectrophotometer are described. The experiments demonstrate the effect of pH, temperature, and inhibitors on enzyme activity and allow the determination of Km, Vmax, and Kcat. These procedures are designed for teaching large lower-level biochemistry classes. (MR)

  11. Simple Psychological Interventions for Reducing Pain From Common Needle Procedures in Adults

    PubMed Central

    Boerner, Katelynn E.; Birnie, Kathryn A.; Taddio, Anna; McMurtry, C. Meghan; Noel, Melanie; Shah, Vibhuti; Pillai Riddell, Rebecca

    2015-01-01

    Background: This systematic review evaluated the effectiveness of simple psychological interventions for managing pain and fear in adults undergoing vaccination or related common needle procedures (ie, venipuncture/venous cannulation). Design/Methods: Databases were searched to identify relevant randomized and quasi-randomized controlled trials. Self-reported pain and fear were prioritized as critically important outcomes. Data were combined using standardized mean difference (SMD) or relative risk (RR) with 95% confidence intervals (CI). Results: No studies involving vaccination met inclusion criteria; evidence was drawn from 8 studies of other common needle procedures (eg, venous cannulation, venipuncture) in adults. Two trials evaluating the impact of neutral signaling of the impending procedure (eg, “ready?”) as compared with signaling of impending pain (eg, “sharp scratch”) demonstrated lower pain when signaled about the procedure (n=199): SMD=−0.97 (95% CI, −1.26, −0.68), after removal of 1 trial where self-reported pain was significantly lower than the other 2 included trials. Two trials evaluated music distraction (n=156) and demonstrated no difference in pain: SMD=0.10 (95% CI, −0.48, 0.27), or fear: SMD=−0.25 (95% CI, −0.61, 0.10). Two trials evaluated visual distraction and demonstrated no difference in pain (n=177): SMD=−0.57 (95% CI, −1.82, 0.68), or fear (n=81): SMD=−0.05 (95% CI, −0.50, 0.40). Two trials evaluating breathing interventions found less pain in intervention groups (n=138): SMD=−0.82 (95% CI, −1.21, −0.43). The quality of evidence across all trials was very low. Conclusions: There are no published studies of simple psychological interventions for vaccination pain in adults. There is some evidence of a benefit from other needle procedures for breathing strategies and neutral signaling of the start of the procedure. There is no evidence for use of music or visual distraction. PMID:26352921

  12. The Synthesis of Proteins-A Simple Experiment To Show the Procedures and Problems of Using Radioisotopes in Biochemical Studies

    NASA Astrophysics Data System (ADS)

    Hawcroft, David M.

    1996-11-01

    Courses of organic chemistry frequently include studies of biochemistry and hence of biochemical techniques. Radioisotopes have played a major role in the understanding of metabolic pathways, transport, enzyme activity and other processes. The experiment described in this paper uses simple techniques to illustrate the procedures involved in working with radioisotopes when following a simplified metabolic pathway. Safety considerations are discussed and a list of safety rules is provided, but the experiment itself uses very low levels of a weak beta-emitting isotope (tritium). Plant material is suggested to reduce legal, financial and emotive problems, but the techniques are applicable to all soft-tissued material. The problems involved in data interpretation in radioisotope experiments resulting from radiation quenching are resolved by simple correction calculations, and the merits of using radioisotopes shown by a calculation of the low mass of material being measured. Suggestions for further experiments are given.

  13. Helicopter vibration suppression using simple pendulum absorbers on the rotor blade

    NASA Technical Reports Server (NTRS)

    Hamouda, M.-N. H.; Pierce, G. A.

    1981-01-01

    A design procedure is presented for the installation of simple pendulums on the blades of a helicopter rotor to suppress the root reactions. The procedure consists of a frequency response analysis for a hingeless rotor blade excited by a harmonic variation of spanwise airload distributions during forward flight, as well as a concentrated load at the tip. The structural modeling of the blade provides for elastic degrees of freedom in flap and lead-lag bending plus torsion. Simple flap and lead-lag pendulums are considered individually. Using a rational order scheme, the general nonlinear equations of motion are linearized. A quasi-steady aerodynamic representation is used in the formation of the airloads. The solution of the system equations derives from their representation as a transfer matrix. The results include the effect of pendulum tuning on the minimization of the hub reactions.

  14. An Approximation to the Adaptive Exponential Integrate-and-Fire Neuron Model Allows Fast and Predictive Fitting to Physiological Data.

    PubMed

    Hertäg, Loreen; Hass, Joachim; Golovko, Tatiana; Durstewitz, Daniel

    2012-01-01

    For large-scale network simulations, it is often desirable to have computationally tractable, yet in a defined sense still physiologically valid neuron models. In particular, these models should be able to reproduce physiological measurements, ideally in a predictive sense, and under different input regimes in which neurons may operate in vivo. Here we present an approach to parameter estimation for a simple spiking neuron model mainly based on standard f-I curves obtained from in vitro recordings. Such recordings are routinely obtained in standard protocols and assess a neuron's response under a wide range of mean-input currents. Our fitting procedure makes use of closed-form expressions for the firing rate derived from an approximation to the adaptive exponential integrate-and-fire (AdEx) model. The resulting fitting process is simple and about two orders of magnitude faster compared to methods based on numerical integration of the differential equations. We probe this method on different cell types recorded from rodent prefrontal cortex. After fitting to the f-I current-clamp data, the model cells are tested on completely different sets of recordings obtained by fluctuating ("in vivo-like") input currents. For a wide range of different input regimes, cell types, and cortical layers, the model could predict spike times on these test traces quite accurately within the bounds of physiological reliability, although no information from these distinct test sets was used for model fitting. Further analyses delineated some of the empirical factors constraining model fitting and the model's generalization performance. An even simpler adaptive LIF neuron was also examined in this context. Hence, we have developed a "high-throughput" model fitting procedure which is simple and fast, with good prediction performance, and which relies only on firing rate information and standard physiological data widely and easily available.

  15. Lorentz-invariant formulation of Cherenkov radiation by tachyons

    NASA Technical Reports Server (NTRS)

    Jones, F. C.

    1972-01-01

    Previous treatments of Cherenkov radiation, electromagnetic and gravitational, by tachyons were in error because the prescription employed to cut off the divergent integral over frequency is not a Lorentz invariant procedure. The resulting equation of motion for the tachyon is therefore not covariant. The proper procedure requires an extended, deformable distribution of charge or mass and yields a particularly simple form for the tachyon's world line, one that could be deduced from simple invariance considerations. It is shown that Cherenkov radiation by tachyons implys their ultimate annihilation with an antitachyon and demonstrates a disturbing property of tachyons, namely the impossibility of specifying arbitrary Cauchy data even in a purely classical theory.

  16. Rapid and simple procedure for homogenizing leaf tissues suitable for mini-midi-scale DNA extraction in rice.

    PubMed

    Yi, Gihwan; Choi, Jun-Ho; Lee, Jong-Hee; Jeong, Unggi; Nam, Min-Hee; Yun, Doh-Won; Eun, Moo-Young

    2005-01-01

    We describe a rapid and simple procedure for homogenizing leaf samples suitable for mini/midi-scale DNA preparation in rice. The methods used tungsten carbide beads and general vortexer for homogenizing leaf samples. In general, two samples can be ground completely within 11.3+/-1.5 sec at one time. Up to 20 samples can be ground at a time using a vortexer attachment. The yields of the DNA ranged from 2.2 to 7.6 microg from 25-150 mg of young fresh leaf tissue. The quality and quantity of DNA was compatible for most of PCR work and RFLP analysis.

  17. Adaptive filtering with the self-organizing map: a performance comparison.

    PubMed

    Barreto, Guilherme A; Souza, Luís Gustavo M

    2006-01-01

    In this paper we provide an in-depth evaluation of the SOM as a feasible tool for nonlinear adaptive filtering. A comprehensive survey of existing SOM-based and related architectures for learning input-output mappings is carried out and the application of these architectures to nonlinear adaptive filtering is formulated. Then, we introduce two simple procedures for building RBF-based nonlinear filters using the Vector-Quantized Temporal Associative Memory (VQTAM), a recently proposed method for learning dynamical input-output mappings using the SOM. The aforementioned SOM-based adaptive filters are compared with standard FIR/LMS and FIR/LMS-Newton linear transversal filters, as well as with powerful MLP-based filters in nonlinear channel equalization and inverse modeling tasks. The obtained results in both tasks indicate that SOM-based filters can consistently outperform powerful MLP-based ones.

  18. Robust aptamer-polydopamine-functionalized M-PLGA-TPGS nanoparticles for targeted delivery of docetaxel and enhanced cervical cancer therapy.

    PubMed

    Xu, Guojun; Yu, Xinghua; Zhang, Jinxie; Sheng, Yingchao; Liu, Gan; Tao, Wei; Mei, Lin

    2016-01-01

    One limitation of current biodegradable polymeric nanoparticles (NPs) is the contradiction between functional modification and maintaining formerly excellent bioproperties with simple procedures. Here, we reported a robust aptamer-polydopamine-functionalized mannitol-functionalized poly(lactide-co-glycolide) (M-PLGA)-D-α-tocopheryl polyethylene glycol 1000 succinate (TPGS) nanoformulation (Apt-pD-NPs) for the delivery of docetaxel (DTX) with enhanced cervical cancer therapy effects. The novel DTX-loaded Apt-pD-NPs possess satisfactory advantages: 1) increased drug loading content and encapsulation efficiency induced by star-shaped copolymer M-PLGA-TPGS; 2) significant active targeting effect caused by conjugated AS1411 aptamers; and 3) excellent long-term compatibility by incorporation of TPGS. Therefore, with simple preparation procedures and excellent bioproperties, the new functionalized Apt-pD-NPs could maximally increase the local effective drug concentration on tumor sites, achieving enhanced treatment effectiveness and minimizing side effects. In a word, the robust DTX-loaded Apt-pD-NPs could be used as potential nanotherapeutics for cervical cancer treatment, and the aptamer-polydopamine modification strategy could be a promising method for active targeting of cancer therapy with simple procedures.

  19. More Powerful Tests of Simple Interaction Contrasts in the Two-Way Factorial Design

    ERIC Educational Resources Information Center

    Hancock, Gregory R.; McNeish, Daniel M.

    2017-01-01

    For the two-way factorial design in analysis of variance, the current article explicates and compares three methods for controlling the Type I error rate for all possible simple interaction contrasts following a statistically significant interaction, including a proposed modification to the Bonferroni procedure that increases the power of…

  20. A Simple Hypnotic Approach to Treat Test Anxiety in Medical Students and Residents.

    ERIC Educational Resources Information Center

    Hebert, Stephen W.

    1984-01-01

    A simple hypnotic procedure to treat test anxiety is described that was used successfully with medical students and residents at the Wake Forest University Medical Center. A light trace is obtained and then the student is told to take such a hypnotic "journey" the evening prior to the test. (MLW)

  1. Quantitation & Case-Study-Driven Inquiry to Enhance Yeast Fermentation Studies

    ERIC Educational Resources Information Center

    Grammer, Robert T.

    2012-01-01

    We propose a procedure for the assay of fermentation in yeast in microcentrifuge tubes that is simple and rapid, permitting assay replicates, descriptive statistics, and the preparation of line graphs that indicate reproducibility. Using regression and simple derivatives to determine initial velocities, we suggest methods to compare the effects of…

  2. Simple determination of aflatoxins in rice by ultra-high performance liquid chromatography coupled to chemical post-column derivatization and fluorescence detection.

    PubMed

    Huertas-Pérez, José Fernando; Arroyo-Manzanares, Natalia; Hitzler, Dominik; Castro-Guerrero, Francisco Germán; Gámiz-Gracia, Laura; García-Campaña, Ana M

    2018-04-15

    A fast and simple analytical method was developed and characterized for the determination of aflatoxins (B 1 , B 2 , G 1 and G 2 ) in rice. The procedure is based on a simple solid-liquid extraction without further clean-up, and analysis by ultra-high performance liquid chromatography coupled with fluorescence detection. Fluorescence emission of aflatoxins B 1 and G 1 was enhanced by post-column chemical derivatization using pyridinium bromide perbromide. The analytical method was satisfactorily characterized in white and brown rice. Under optimum conditions, external calibration in solvent could be used for quantification purposes and limits of quantification were below the maximum contents established by the European Union regulation for these contaminants/commodity group combination (0.07-0.14 µg/kg for white rice and 0.20-0.28 µg/kg for brown rice). Recovery studies carried out at three different concentration levels (0.5, 2 and 5 µg/kg) showed values in the range of 84.5-105.3%, and RSDs ≤ 5%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Simple and rapid quantification of brominated vegetable oil in commercial soft drinks by LC–MS

    PubMed Central

    Chitranshi, Priyanka; da Costa, Gonçalo Gamboa

    2016-01-01

    We report here a simple and rapid method for the quantification of brominated vegetable oil (BVO) in soft drinks based upon liquid chromatography–electrospray ionization mass spectrometry. Unlike previously reported methods, this novel method does not require hydrolysis, extraction or derivatization steps, but rather a simple “dilute and shoot” sample preparation. The quantification is conducted by mass spectrometry in selected ion recording mode and a single point standard addition procedure. The method was validated in the range of 5–25 μg/mL BVO, encompassing the legal limit of 15 μg/mL established by the US FDA for fruit-flavored beverages in the US market. The method was characterized by excellent intra- and inter-assay accuracy (97.3–103.4%) and very low imprecision [0.5–3.6% (RSD)]. The direct nature of the quantification, simplicity, and excellent statistical performance of this methodology constitute clear advantages in relation to previously published methods for the analysis of BVO in soft drinks. PMID:27451219

  4. Adjusting the Stems Regional Forest Growth Model to Improve Local Predictions

    Treesearch

    W. Brad Smith

    1983-01-01

    A simple procedure using double sampling is described for adjusting growth in the STEMS regional forest growth model to compensate for subregional variations. Predictive accuracy of the STEMS model (a distance-independent, individual tree growth model for Lake States forests) was improved by using this procedure

  5. EYEBLINK CONDITIONING IN THE INFANT RAT: AN ANIMAL MODEL OF LEARNING IN DEVELOPMENTAL NEUROTOXICOLOGY

    EPA Science Inventory

    Classical conditioning of the eyeblink reflex is a relatively simple procedure for studying associative learning that was first developed for use with human subjects more than half a century ago. The use of this procedure in laboratory animals by psychologists and neuro-scientist...

  6. How to Use Chromatography as a Science Teaching Aid.

    ERIC Educational Resources Information Center

    Ganis, Frank M.

    Presented are five procedures which permit the effective teaching of chromatography with equipment which is readily available, economical, and simple in design. The first procedure involves a study of solute partition in two immiscible solvents and of countercurrent distribution. The second illustrates the use of unidimensional ascending paper…

  7. Speed and Accuracy in the Processing of False Statements About Semantic Information.

    ERIC Educational Resources Information Center

    Ratcliff, Roger

    1982-01-01

    A standard reaction time procedure and a response signal procedure were used on data from eight experiments on semantic verifications. Results suggest that simple models of the semantic verification task that assume a single yes/no dimension on which discrimination is made are not correct. (Author/PN)

  8. Students' clinical experience on outreach placements.

    PubMed

    Smith, M; Lennon, M A; Robinson, P G

    2010-02-01

    Primary care outreach placements increasingly feature in UK undergraduate dental curricula. The profile of clinical work undertaken on placement may differ from traditional hospital-based programmes and between outreach settings. An appreciation of any differences could inform curriculum development. To compare the profiles of clinical work experienced on a traditional hospital-based programme and outreach placements in different settings. One dental hospital and eight existing primary care block placements in England. Subjects were four cohorts of senior dental students in one UK dental school. Departmental records provided data on students' clinical experience in different settings and their achievement of placement learning objectives. Descriptive statistics for groups were compared. (1) Counts of patients encountered and of clinical procedures completed in the following categories: simple plastic restorations, endodontics, cast restorations, dentures, extractions and children's dentistry. (2) Student perceptions of placement learning reported via Likert scales. Outreach students encountered twice as many patients and typically completed about three times as much clinical work as students in the hospital, e.g. 44 cf 16 simple plastic restorations, seven cf two endodontic procedures. There were variations in profiles by setting. For example, amalgam being more likely to be used on outreach especially in the General Dental Service; more children's dentistry in community services and more extractions in Dental Access Centres. Students reported learning outcomes generally being achieved (average 94%) although with some variation by setting. Dental outreach training greatly increases the quantity of students' clinical experience in everyday dentistry compared to a hospital-based programme. Placements also increase awareness of service delivery and develop clinical skills. There are appreciable variations between outreach settings possibly reflecting their purposes. Multiple contrasting outreach placements for each student might increase the uniformity of learning experiences.

  9. New Method for Evaluation of Virucidal Activity of Antiseptics and Disinfectants

    PubMed Central

    Papageorgiou, Georgios T.; Mocé-Llivina, Laura; Jofre, Juan

    2001-01-01

    Counting culturable viruses adsorbed to cellulose nitrate filters (the VIRADEN method) is proposed as a simple procedure for the evaluation of the virucidal activity of antiseptics and disinfectants. The virucidal activities of two different doses of iodine, chlorine, glutaraldehyde, and chlorhexidine digluconate on poliovirus 1 were tested with a standardized procedure and with the VIRADEN method. The two procedures assayed provided similar results. PMID:11722944

  10. Movement suppression time-out for undesirable behavior in psychotic and severely developmentally delayed children.

    PubMed

    Rolider, A; Van Houten, R

    1985-01-01

    The effects of a movement suppression time-out, which involved punishing any movement or verbalization while a client is in the time-out area, were evaluated in four experiments. The first experiment examined the effects of a DRO procedure and movement suppression plus DRO in suppressing self-injurious behavior in a psychotic child in three different situations. In Experiment 2, the results of the previous experiment were replicated with two dangerous behaviors in a second psychotic child. In a third experiment, movement suppression plus DRO was compared with contingent restraint in reducing inappropriate poking behavior in two settings. The movement suppression procedure eliminated poking whereas contingent restraint had little effect. In the final experiment, movement suppression time-out alone was compared with exclusionary time-out alone and simple corner time-out alone. Self-stimulation occurred at high levels during the exclusionary and simple corner time-out procedures. Self-stimulation was either suppressed or reduced during movement suppression time-out. The movement suppression time-out procedure produced a larger reduction in the target behavior in all three children. The effectiveness of the movement suppression procedure was explained in terms of the suppression of self-stimulation while the time-out procedure was being applied.

  11. dc analysis and design of zero-voltage-switched multi-resonant converters

    NASA Astrophysics Data System (ADS)

    Tabisz, Wojciech A.; Lee, Fred C.

    Recently introduced multiresonant converters (MRCs) provide zero-voltage switching (ZVS) of both active and passive switches and offer a substantial reduction of transistor voltage stress and an increase of load range, compared to their quasi-resonant converter counterparts. Using the resonant switch concept, a simple, generalized analysis of ZVS MRCs is presented. The conversion ratio and voltage stress characteristics are derived for basic ZVS MRCs, including buck, boost, and buck/boost converters. Based on the analysis, a design procedure that optimizes the selection of resonant elements for maximum conversion efficiency is proposed.

  12. Recursive sequences in first-year calculus

    NASA Astrophysics Data System (ADS)

    Krainer, Thomas

    2016-02-01

    This article provides ready-to-use supplementary material on recursive sequences for a second-semester calculus class. It equips first-year calculus students with a basic methodical procedure based on which they can conduct a rigorous convergence or divergence analysis of many simple recursive sequences on their own without the need to invoke inductive arguments as is typically required in calculus textbooks. The sequences that are accessible to this kind of analysis are predominantly (eventually) monotonic, but also certain recursive sequences that alternate around their limit point as they converge can be considered.

  13. Free vibration of arches flexible in shear.

    NASA Technical Reports Server (NTRS)

    Austin, W. J.; Veletsos, A. S.

    1973-01-01

    An analysis reported by Veletsos et al. (1972) concerning the free vibrational characteristics of circular arches vibrating in their own planes is considered. The analysis was based on a theory which neglects the effects of rotatory inertia and shearing deformation. A supplementary investigation is conducted to assess the effects of the previously neglected factors and to identify the conditions under which these effects are of practical significance or may be neglected. A simple approximate procedure is developed for estimating the natural frequencies of arches, giving due consideration to the effects of the previously neglected factors.

  14. Scan blindness in infinite phased arrays of printed dipoles

    NASA Technical Reports Server (NTRS)

    Pozar, D. M.; Schaubert, D. H.

    1984-01-01

    A comprehensive study of infinite phased arrays of printed dipole antennas is presented, with emphasis on the scan blindness phenomenon. A rigorous and efficient moment method procedure is used to calculate the array impedance versus scan angle. Data are presented for the input reflection coefficient for various element spacings and substrate parameters. A simple theory, based on coupling from Floquet modes to surface wave modes on the substrate, is shown to predict the occurrence of scan blindness. Measurements from a waveguide simulator of a blindness condition confirm the theory.

  15. CuO nanoparticles catalyzed C-N, C-O, and C-S cross-coupling reactions: scope and mechanism.

    PubMed

    Jammi, Suribabu; Sakthivel, Sekarpandi; Rout, Laxmidhar; Mukherjee, Tathagata; Mandal, Santu; Mitra, Raja; Saha, Prasenjit; Punniyamurthy, Tharmalingam

    2009-03-06

    CuO nanoparticles have been studied for C-N, C-O, and C-S bond formations via cross-coupling reactions of nitrogen, oxygen, and sulfur nucleophiles with aryl halides. Amides, amines, imidazoles, phenols, alcohols and thiols undergo reactions with aryl iodides in the presence of a base such as KOH, Cs(2)CO(3), and K(2)CO(3) at moderate temperature. The procedure is simple, general, ligand-free, and efficient to afford the cross-coupled products in high yield.

  16. Combined distribution functions: A powerful tool to identify cation coordination geometries in liquid systems

    NASA Astrophysics Data System (ADS)

    Sessa, Francesco; D'Angelo, Paola; Migliorati, Valentina

    2018-01-01

    In this work we have developed an analytical procedure to identify metal ion coordination geometries in liquid media based on the calculation of Combined Distribution Functions (CDFs) starting from Molecular Dynamics (MD) simulations. CDFs provide a fingerprint which can be easily and unambiguously assigned to a reference polyhedron. The CDF analysis has been tested on five systems and has proven to reliably identify the correct geometries of several ion coordination complexes. This tool is simple and general and can be efficiently applied to different MD simulations of liquid systems.

  17. The energy-momentum tensor(s) in classical gauge theories

    DOE PAGES

    Blaschke, Daniel N.; Gieres, François; Reboud, Méril; ...

    2016-07-12

    We give an introduction to, and review of, the energy-momentum tensors in classical gauge field theories in Minkowski space, and to some extent also in curved space-time. For the canonical energy-momentum tensor of non-Abelian gauge fields and of matter fields coupled to such fields, we present a new and simple improvement procedure based on gauge invariance for constructing a gauge invariant, symmetric energy-momentum tensor. In conclusion, the relationship with the Einstein-Hilbert tensor following from the coupling to a gravitational field is also discussed.

  18. Phosphate conversion coating reduces the degradation rate and suppresses side effects of metallic magnesium implants in an animal model.

    PubMed

    Rahim, Muhammad Imran; Tavares, Ana; Evertz, Florian; Kieke, Marc; Seitz, Jan-Marten; Eifler, Rainer; Weizbauer, Andreas; Willbold, Elmar; Jürgen Maier, Hans; Glasmacher, Birgit; Behrens, Peter; Hauser, Hansjörg; Mueller, Peter P

    2017-08-01

    Magnesium alloys have promising mechanical and biological properties for the development of degradable implants. However, rapid implant corrosion and gas accumulations in tissue impede clinical applications. With time, the implant degradation rate is reduced by a highly biocompatible, phosphate-containing corrosion layer. To circumvent initial side effects after implantation it was attempted to develop a simple in vitro procedure to generate a similarly protective phosphate corrosion layer. To this end magnesium samples were pre-incubated in phosphate solutions. The resulting coating was well adherent during routine handling procedures. It completely suppressed the initial burst of corrosion and it reduced the average in vitro magnesium degradation rate over 56 days almost two-fold. In a small animal model phosphate coatings on magnesium implants were highly biocompatible and abrogated the appearance of gas cavities in the tissue. After implantation, the phosphate coating was replaced by a layer with an elemental composition that was highly similar to the corrosion layer that had formed on plain magnesium implants. The data demonstrate that a simple pre-treatment could improve clinically relevant properties of magnesium-based implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1622-1635, 2017. © 2016 Wiley Periodicals, Inc.

  19. Role of cytopathology in cancer control in low-resource settings: sub-Saharan Africa's perspective.

    PubMed

    Thomas, Jaiyeola

    2011-03-01

    Cancer is an emerging public health problem in Africa especially with increasing exposure to risky life styles, environmental carcinogens and emergence of AIDS-associated cancers. Of the WHO estimated 7.9 million cancer-related deaths in 2007 more than 72% occurred in the low- and middle-income countries and 80% presented in the late stages. To implement the WHO resolution on cancer control programs in these settings, feasible evidence-based interventions for prevention, early diagnosis and detection need to be widely introduced. Fundamental to appropriate cancer treatment and statistics is accurate diagnosis. In low-resource settings, the diagnostic techniques and procedures should be reliable, cost-effective, simple and acceptable to patients. In addition, the required equipment should be affordable, requiring minimal maintenance and with readily available consumables. Cytology, as a simple standardized low-technology procedure, fulfills these criteria and is most effective in addressing the major components of cancer control programs in these areas. The major obstacles to its widespread establishment are lack of awareness and inadequate numbers of trained personnel compounded by sociopolitical factors, poor national planning and implementation. Rather than investing in new technology or alternative screening methods, efforts should focus on the education and training of local personnel, as feasible options, to improve the chances of implementing meaningful cancer control programs.

  20. THE EFFECTS OF A SIMPLE METHOD FOR CRYOPRESERVATION AND THAWING PROCEDURES ON CORD BLOOD DERIVED DC-BASED ESOPHAGEAL CARCINOMA VACCINE.

    PubMed

    Yu, J; Xie, L; Chen, S; Zhang, J; Guo, G; Chen, B

    Producing sufficient numbers of DCs at one time point and subsequently cryopreserving the generated DCs in ready-for-use aliquots for clinical application is useful in cancer treatment. To study the effects of a simplified cryopreservation method and thawing procedures acting on the biological characteristics and specific cytotoxic activity of cord blood derived DC-based esophageal carcinoma vaccine. CD34+ hematopoietic stem cells were isolated from cord blood using CD34+ Progenitor Cell Isolation Kit by magnetic cell sorting system (MACS). The CD34+ cells were expanded with cytokines as DCs, and fused with EC109 cells by PEG-3600. The fused cells were transferred to a freezing tube without rate-controlled freezing and stored at -80 degree C for three weeks. During cryopreservation, 2.5% DMSO, 2.5% glucose and 10% FCS at final concentration was used as stock solution. After thawing, cells were assayed for Typan blue viability, morphology, immunophenotypes and T-cell stimulatory capacity, and specific CTL activity. Cryopreservation does not cause significant changes in the phenotypes expression or morphology of the fused cells, and the viability were well preserved (Typan blue viability was 77.2±1.8%). After being stimulated by DC-based esophageal carcinoma vaccine either before or after cryopreservation, the numbers of CD3+T/CD4+T and CD3+T/CD8+T lymphocytes increased obviously, especially for CD3+T/CD4+T, and the ratio of CD4/CD8 changed from 0.85 to 1.29 and 1.25 respectively. Specific CTL activity were well preserved (compare to the fresh fused vaccine, P>0.05). A simple -80 degree C freezing and storage method is practical for cord blood derived DC-based esophageal carcinoma vaccine. It will greatly facilitate the clinical use of DC-based vaccine for immunotherapy.

  1. Bacterial Expression of a Single-Chain Variable Fragment (scFv) Antibody against Ganoderic Acid A: A Cost-Effective Approach for Quantitative Analysis Using the scFv-Based Enzyme-Linked Immunosorbent Assay.

    PubMed

    Yusakul, Gorawit; Nuntawong, Poomraphie; Sakamoto, Seiichi; Ratnatilaka Na Bhuket, Pahweenvaj; Kohno, Toshitaka; Kikkawa, Nao; Rojsitthisak, Pornchai; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi

    2017-01-01

    Due to the highly specific binding between an antibody and its target, superior analytical performances was obtained by immunoassays for phytochemical analysis over conventional chromatographic techniques. Here, we describe a simple method for producing a functional single-chain variable fragment (scFv) antibody against ganoderic acid A (GAA), a pharmacologically active metabolite from Ganoderma lingzhi. The Escherichia coli BL21(DE3) strain produced a large amount of anti-GAA scFv. However, in vitro refolding steps, which partially recovered the reactivity of the scFv, were required. Interestingly, the functional scFv was expressed as a soluble and active form in the cytoplasm of an engineered E. coli SHuffle ® strain. Purified anti-GAA scFv, which yielded 2.56 mg from 1 L of culture medium, was obtained from simple and inexpensive procedures for expression and purification. The anti-GAA scFv-based indirect competitive enzyme-linked immunosorbent assay (icELISA) exhibited high sensitivity (linearity: 0.078-1.25 µg/mL) with precision (CV: ≤6.20%) and reliability (recovery: 100.1-101.8%) for GAA determination. In summary, the approach described here is an inexpensive, simple, and efficient expression system that extends the application of anti-GAA scFv-based immunoassays. In addition, when in vitro refolding steps can be skipped, the cost and complexity of scFv antibody production can be minimized.

  2. Liquid-liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel.

    PubMed

    Pereira, Andréia C; Rocha, Fábio R P

    2014-06-04

    A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I3(-) reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I2/100 g with a detection limit of 5 g I2/100 g. A coefficient of variation of 1.7% (n=10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel. Copyright © 2014. Published by Elsevier B.V.

  3. Aggregative Learning Method and Its Application for Communication Quality Evaluation

    NASA Astrophysics Data System (ADS)

    Akhmetov, Dauren F.; Kotaki, Minoru

    2007-12-01

    In this paper, so-called Aggregative Learning Method (ALM) is proposed to improve and simplify the learning and classification abilities of different data processing systems. It provides a universal basis for design and analysis of mathematical models of wide class. A procedure was elaborated for time series model reconstruction and analysis for linear and nonlinear cases. Data approximation accuracy (during learning phase) and data classification quality (during recall phase) are estimated from introduced statistic parameters. The validity and efficiency of the proposed approach have been demonstrated through its application for monitoring of wireless communication quality, namely, for Fixed Wireless Access (FWA) system. Low memory and computation resources were shown to be needed for the procedure realization, especially for data classification (recall) stage. Characterized with high computational efficiency and simple decision making procedure, the derived approaches can be useful for simple and reliable real-time surveillance and control system design.

  4. Detection of Cherenkov Photons with Multi-Anode Photomultipliers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salazar, H.; Moreno, E.; Murrieta, T.

    2006-09-25

    The present paper describes the laboratory course given at the X Mexican Workshop on Particles and Fields. We describe the setup and procedure used to measure the Cherenkov circles produced by cosmic muons upon traversal of a simple glass radiator system. The main purpose of this exercise is to introduce the students to work with multi-anode photomultipliers such as the one used for this experiment (Hamamatsu R5900-M64), with which measurements requiring position sensitive detection of single photons can be successfully performed. We present a short introduction to multi-anode photomultipliers (MAPMT) and describe the setup and the procedure used to measuremore » the response of a MAPMT to a uniform source of light. Finally, we describe the setup and procedure used to measure the Cherenkov circles produced by cosmic muons upon traversal of a simple glass radiator system.« less

  5. Molecularly imprinted polymer-based solid phase clean-up for analysis of ochratoxin A in beer, red wine, and grape juice.

    PubMed

    Cao, Jiliang; Kong, Weijun; Zhou, Shujun; Yin, Lihui; Wan, Li; Yang, Meihua

    2013-04-01

    A simple, reliable, and low-cost method based on molecularly imprinted polymer as a selective sorbent of SPE was proposed for the determination of ochratoxin A (OTA) in beer, red wine, and grape juice by HPLC coupled with fluorescence detection (HPLC-FLD). Samples were diluted with water and cleaned up with an AFFINIMIP® SPE OTA column. After washing and eluting, the analyte was analyzed by HPLC-FLD. Under the optimized conditions, LOD and LOQ for OTA were 0.025 and 0.08 ng/mL, respectively. The recoveries of OTA from beer, red wine, and grape spiked at 0.1, 2, and 5 ng/mL ranged from 91.6 to 101.7%. Furthermore, after a simple regenerated procedure, the molecularly imprinted polymer based SPE column could be reused at least 14 times to achieve more than 80% recoveries of OTA in real samples. The developed method was applied to the detection of 30 beer, red wine, and grape juice samples and only four samples were contaminated by OTA with levels below the legal limits. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Turbomachinery Airfoil Design Optimization Using Differential Evolution

    NASA Technical Reports Server (NTRS)

    Madavan, Nateri K.; Biegel, Bryan A. (Technical Monitor)

    2002-01-01

    An aerodynamic design optimization procedure that is based on a evolutionary algorithm known at Differential Evolution is described. Differential Evolution is a simple, fast, and robust evolutionary strategy that has been proven effective in determining the global optimum for several difficult optimization problems, including highly nonlinear systems with discontinuities and multiple local optima. The method is combined with a Navier-Stokes solver that evaluates the various intermediate designs and provides inputs to the optimization procedure. An efficient constraint handling mechanism is also incorporated. Results are presented for the inverse design of a turbine airfoil from a modern jet engine. The capability of the method to search large design spaces and obtain the optimal airfoils in an automatic fashion is demonstrated. Substantial reductions in the overall computing time requirements are achieved by using the algorithm in conjunction with neural networks.

  7. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator

    PubMed Central

    Moses, Matthew S.; Murphy, Ryan J.; Kutzer, Michael D. M.; Armand, Mehran

    2016-01-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy. PMID:27818607

  8. Modeling Cable and Guide Channel Interaction in a High-Strength Cable-Driven Continuum Manipulator.

    PubMed

    Moses, Matthew S; Murphy, Ryan J; Kutzer, Michael D M; Armand, Mehran

    2015-12-01

    This paper presents several mechanical models of a high-strength cable-driven dexterous manipulator designed for surgical procedures. A stiffness model is presented that distinguishes between contributions from the cables and the backbone. A physics-based model incorporating cable friction is developed and its predictions are compared with experimental data. The data show that under high tension and high curvature, the shape of the manipulator deviates significantly from a circular arc. However, simple parametric models can fit the shape with good accuracy. The motivating application for this study is to develop a model so that shape can be predicted using easily measured quantities such as tension, so that real-time navigation may be performed, especially in minimally-invasive surgical procedures, while reducing the need for hazardous imaging methods such as fluoroscopy.

  9. Rapid Synthesis of 68Ga-labeled macroaggregated human serum albumin (MAA) for routine application in perfusion imaging using PET/CT.

    PubMed

    Mueller, D; Kulkarni, Harshad; Baum, Richard P; Odparlik, Andreas

    2017-04-01

    99m Tc-labeled MAA is commonly used for single photon emission computed tomography SPECT. In contrast, positron emission tomography/CT (PET/CT) delivers images with significantly higher resolution. The generator produced radionuclide 68 Ga is widely used for PET/CT imaging agents and 68 Ga-labeled MAA represents an attractive alternative to 99m Tc-labeled MAA. We report a simple and rapid NaCl based labeling procedure for the labeling of MAA with 68 Ga using a commercially available MAA labeling kit for 99m Tc. The procedure delivers 68 Ga-labeled MAA with a high specific activity and a high labeling efficiency (>99%). The synthesis does not require a final step of separation or the use of organic solvents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Efficacy of a Procedure-Specific Education Module on Informed Consent in Plastic Surgery.

    PubMed

    Brandel, Michael G; Reid, Christopher M; Parmeshwar, Nisha; Dobke, Marek K; Gosman, Amanda A

    2017-05-01

    Truly informed consent is an elusive goal, seldom attained in medical or surgical practice. Patients often do not fully understand procedures and therapies they undergo or the associated sequelae. Historically, informed consent and patient education have been limited to physician discussions, sometimes with the addition of simple visual aids. More recently, there is a growing body of decision aids available, including interactive multimedia patient educational modules that review preoperative through postoperative care, risks, benefits, alternatives, different surgical options, as well as commonly asked questions. We hypothesized that the addition of a Web-based educational tool would positively impact attainment of informed consent and satisfaction in plastic surgery patients. We performed a prospective randomized controlled study comparing patients who presented in consultation for breast reconstruction, breast reduction, and abdominoplasty. Patients received standard patient education along with a procedure-specific (study) or general patient safety (control) Web-based educational module. Informed consent was measured using a surgical-focused, modified version of the Shared Decision-making 25 index tool. Patient demographic information as well as surrogate markers of familiarity with technology were recorded preoperatively and postoperatively. Comparisons were made between study and control groups, procedure subgroups, and preoperative and postoperative time points. Demographic factors and consent variables were compared among experimental and procedure groups. Data were collected from 65 patients preoperatively and 48 patients postoperatively. Thirty patients competed both surveys. Overall, no differences in patient characteristics or familiarity with technology were observed between experimental groups. Demographic characteristics were also similar between groups. No meaningful differences were identified in comparisons between experimental groups on either cross-sectional or longitudinal analyses. Nearly all patient responses were consistent with being well informed and satisfied with the educational process. Overall, patients undergoing plastic surgery procedures are adequately informed and have a high degree of satisfaction regarding their patient education. The addition of a Web-based informed consent tool did not make a demonstrable difference in informed consent.

  11. Prediction of fermentation index of cocoa beans (Theobroma cacao L.) based on color measurement and artificial neural networks.

    PubMed

    León-Roque, Noemí; Abderrahim, Mohamed; Nuñez-Alejos, Luis; Arribas, Silvia M; Condezo-Hoyos, Luis

    2016-12-01

    Several procedures are currently used to assess fermentation index (FI) of cocoa beans (Theobroma cacao L.) for quality control. However, all of them present several drawbacks. The aim of the present work was to develop and validate a simple image based quantitative procedure, using color measurement and artificial neural network (ANNs). ANN models based on color measurements were tested to predict fermentation index (FI) of fermented cocoa beans. The RGB values were measured from surface and center region of fermented beans in images obtained by camera and desktop scanner. The FI was defined as the ratio of total free amino acids in fermented versus non-fermented samples. The ANN model that included RGB color measurement of fermented cocoa surface and R/G ratio in cocoa bean of alkaline extracts was able to predict FI with no statistical difference compared with the experimental values. Performance of the ANN model was evaluated by the coefficient of determination, Bland-Altman plot and Passing-Bablok regression analyses. Moreover, in fermented beans, total sugar content and titratable acidity showed a similar pattern to the total free amino acid predicted through the color based ANN model. The results of the present work demonstrate that the proposed ANN model can be adopted as a low-cost and in situ procedure to predict FI in fermented cocoa beans through apps developed for mobile device. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A simple methodology for characterization of germanium coaxial detectors by using Monte Carlo simulation and evolutionary algorithms.

    PubMed

    Guerra, J G; Rubiano, J G; Winter, G; Guerra, A G; Alonso, H; Arnedo, M A; Tejera, A; Gil, J M; Rodríguez, R; Martel, P; Bolivar, J P

    2015-11-01

    The determination in a sample of the activity concentration of a specific radionuclide by gamma spectrometry needs to know the full energy peak efficiency (FEPE) for the energy of interest. The difficulties related to the experimental calibration make it advisable to have alternative methods for FEPE determination, such as the simulation of the transport of photons in the crystal by the Monte Carlo method, which requires an accurate knowledge of the characteristics and geometry of the detector. The characterization process is mainly carried out by Canberra Industries Inc. using proprietary techniques and methodologies developed by that company. It is a costly procedure (due to shipping and to the cost of the process itself) and for some research laboratories an alternative in situ procedure can be very useful. The main goal of this paper is to find an alternative to this costly characterization process, by establishing a method for optimizing the parameters of characterizing the detector, through a computational procedure which could be reproduced at a standard research lab. This method consists in the determination of the detector geometric parameters by using Monte Carlo simulation in parallel with an optimization process, based on evolutionary algorithms, starting from a set of reference FEPEs determined experimentally or computationally. The proposed method has proven to be effective and simple to implement. It provides a set of characterization parameters which it has been successfully validated for different source-detector geometries, and also for a wide range of environmental samples and certified materials. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Artificial Neural Network Based Fault Diagnostics of Rolling Element Bearings Using Time-Domain Features

    NASA Astrophysics Data System (ADS)

    Samanta, B.; Al-Balushi, K. R.

    2003-03-01

    A procedure is presented for fault diagnosis of rolling element bearings through artificial neural network (ANN). The characteristic features of time-domain vibration signals of the rotating machinery with normal and defective bearings have been used as inputs to the ANN consisting of input, hidden and output layers. The features are obtained from direct processing of the signal segments using very simple preprocessing. The input layer consists of five nodes, one each for root mean square, variance, skewness, kurtosis and normalised sixth central moment of the time-domain vibration signals. The inputs are normalised in the range of 0.0 and 1.0 except for the skewness which is normalised between -1.0 and 1.0. The output layer consists of two binary nodes indicating the status of the machine—normal or defective bearings. Two hidden layers with different number of neurons have been used. The ANN is trained using backpropagation algorithm with a subset of the experimental data for known machine conditions. The ANN is tested using the remaining set of data. The effects of some preprocessing techniques like high-pass, band-pass filtration, envelope detection (demodulation) and wavelet transform of the vibration signals, prior to feature extraction, are also studied. The results show the effectiveness of the ANN in diagnosis of the machine condition. The proposed procedure requires only a few features extracted from the measured vibration data either directly or with simple preprocessing. The reduced number of inputs leads to faster training requiring far less iterations making the procedure suitable for on-line condition monitoring and diagnostics of machines.

  14. Office-based Relaxing Incision Procedure for Correction of Astigmatism after Deep Anterior Lamellar Keratoplasty

    PubMed Central

    Javadi, Mohammad Ali; Feizi, Sepehr; Mirbabaee, Firooz; Fekri, Yousef

    2017-01-01

    Purpose: To report the outcomes of a simple and effective office-based procedure for the correction of astigmatism after deep anterior lamellar keratoplasty (DALK). Methods: This study enrolled 24 consecutive keratoconic eyes that developed an intolerable amount of graft astigmatism after DALK. The location and extension of steep semi-meridians were determined using corneal topography. Office-based relaxing incision procedures were performed at the slit-lamp biomicroscope using a 27-gauge needle. Relaxing incisions were made at the donor-recipient interface on one side of the steepest meridian with an arc length of 45° to 60° and an initial depth of approximately 70–80% of the corneal thickness. Topography was performed after 30–40 minutes and the initial incision was enhanced in depth and length. If an acceptable amount of astigmatism was not achieved, another incision was created at the opposite semi-meridian during the same session. Results: Mean follow-up period was 13.1 ± 7.4 months. Mean preoperative best spectacle corrected visual acuity was 0.26 ± 0.14 logMAR, increasing to 0.22 ± 0.09 logMAR after the procedure (P = 0.20). Mean spherical equivalent refractive error increased from − 4.64 ± 3.06 diopters (D) preoperatively to −6.06 ± 3.15 D postoperatively (P = 0.01). Mean keratometric astigmatism was reduced by 2.95 ± 3.43 D and 5.16 ± 2.97 D measured using subtraction and vector analysis methods, respectively (P < 0.001). Microperforation occurred in one eye, which spontaneously improved with no sequelae. Conclusion: Office-based relaxing incision is a safe and effective procedure for the treatment of corneal graft astigmatism after DALK. This approach effectively decreases the need for the more costly alternative in the operating room. PMID:28540006

  15. A competitive immunoassay for sensitive detection of small molecules chloramphenicol based on luminol functionalized silver nanoprobe.

    PubMed

    Yu, Xiuxia; He, Yi; Jiang, Jie; Cui, Hua

    2014-02-17

    Chloramphenicol (CHL) as a broad-spectrum antibiotic has a broad action spectrum against Gram-positive and Gram-negative bacteria, as well as anaerobes. The use of CHL is strictly restricted in poultry because of its toxic effect. However, CHL is still illegally used in animal farming because of its accessibility and low cost. Therefore, sensitive methods are highly desired for the determination of CHL in foodstuffs. The immunoassays based on labeling as an important tool have been reported for the detection of CHL residues in food-producing animals. However, most of the labeling procedures require multi-step reactions and purifications and thus they are complicated and time-consuming. Recently, in our previous work, luminol functionalized silver nanoparticles have been successfully synthesized, which exhibits higher CL efficiency than luminol functionalized gold nanoparticles. In this work, the new luminol functionalized silver nanoparticles have been used for the labeling of small molecules CHL for the first time and a competitive chemiluminescent immunoassay has been developed for the detection of CHL. Owing to the amplification of silver nanoparticles, high sensitivity for CHL could be achieved with a low detection limit of 7.6×10(-9) g mL(-1) and a wide linear dynamic range of 1.0×10(-8)-1.0×10(-6) g mL(-1). This method has also been successfully applied to determine CHL in milk and honey samples with a good recoveries (92% and 102%, 99% and 107% respectively), indicating that the method is feasible for the determination of CHL in real milk and honey samples. The labeling procedure is simple, convenient and fast, superior to previously reported labeling procedures. The immunoassay is also simple, fast, sensitive and selective. It is of application potential for the determination of CHL in foodstuffs. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Fusion primer and nested integrated PCR (FPNI-PCR): a new high-efficiency strategy for rapid chromosome walking or flanking sequence cloning

    PubMed Central

    2011-01-01

    Background The advent of genomics-based technologies has revolutionized many fields of biological enquiry. However, chromosome walking or flanking sequence cloning is still a necessary and important procedure to determining gene structure. Such methods are used to identify T-DNA insertion sites and so are especially relevant for organisms where large T-DNA insertion libraries have been created, such as rice and Arabidopsis. The currently available methods for flanking sequence cloning, including the popular TAIL-PCR technique, are relatively laborious and slow. Results Here, we report a simple and effective fusion primer and nested integrated PCR method (FPNI-PCR) for the identification and cloning of unknown genomic regions flanked known sequences. In brief, a set of universal primers was designed that consisted of various 15-16 base arbitrary degenerate oligonucleotides. These arbitrary degenerate primers were fused to the 3' end of an adaptor oligonucleotide which provided a known sequence without degenerate nucleotides, thereby forming the fusion primers (FPs). These fusion primers are employed in the first step of an integrated nested PCR strategy which defines the overall FPNI-PCR protocol. In order to demonstrate the efficacy of this novel strategy, we have successfully used it to isolate multiple genomic sequences namely, 21 orthologs of genes in various species of Rosaceace, 4 MYB genes of Rosa rugosa, 3 promoters of transcription factors of Petunia hybrida, and 4 flanking sequences of T-DNA insertion sites in transgenic tobacco lines and 6 specific genes from sequenced genome of rice and Arabidopsis. Conclusions The successful amplification of target products through FPNI-PCR verified that this novel strategy is an effective, low cost and simple procedure. Furthermore, FPNI-PCR represents a more sensitive, rapid and accurate technique than the established TAIL-PCR and hiTAIL-PCR procedures. PMID:22093809

  17. 3D spherical-cap fitting procedure for (truncated) sessile nano- and micro-droplets & -bubbles.

    PubMed

    Tan, Huanshu; Peng, Shuhua; Sun, Chao; Zhang, Xuehua; Lohse, Detlef

    2016-11-01

    In the study of nanobubbles, nanodroplets or nanolenses immobilised on a substrate, a cross-section of a spherical cap is widely applied to extract geometrical information from atomic force microscopy (AFM) topographic images. In this paper, we have developed a comprehensive 3D spherical-cap fitting procedure (3D-SCFP) to extract morphologic characteristics of complete or truncated spherical caps from AFM images. Our procedure integrates several advanced digital image analysis techniques to construct a 3D spherical-cap model, from which the geometrical parameters of the nanostructures are extracted automatically by a simple algorithm. The procedure takes into account all valid data points in the construction of the 3D spherical-cap model to achieve high fidelity in morphology analysis. We compare our 3D fitting procedure with the commonly used 2D cross-sectional profile fitting method to determine the contact angle of a complete spherical cap and a truncated spherical cap. The results from 3D-SCFP are consistent and accurate, while 2D fitting is unavoidably arbitrary in the selection of the cross-section and has a much lower number of data points on which the fitting can be based, which in addition is biased to the top of the spherical cap. We expect that the developed 3D spherical-cap fitting procedure will find many applications in imaging analysis.

  18. Nonlinear Modeling by Assembling Piecewise Linear Models

    NASA Technical Reports Server (NTRS)

    Yao, Weigang; Liou, Meng-Sing

    2013-01-01

    To preserve nonlinearity of a full order system over a parameters range of interest, we propose a simple modeling approach by assembling a set of piecewise local solutions, including the first-order Taylor series terms expanded about some sampling states. The work by Rewienski and White inspired our use of piecewise linear local solutions. The assembly of these local approximations is accomplished by assigning nonlinear weights, through radial basis functions in this study. The efficacy of the proposed procedure is validated for a two-dimensional airfoil moving at different Mach numbers and pitching motions, under which the flow exhibits prominent nonlinear behaviors. All results confirm that our nonlinear model is accurate and stable for predicting not only aerodynamic forces but also detailed flowfields. Moreover, the model is robustness-accurate for inputs considerably different from the base trajectory in form and magnitude. This modeling preserves nonlinearity of the problems considered in a rather simple and accurate manner.

  19. Polyethyleneimine-modified superparamagnetic Fe3O4 nanoparticles: An efficient, reusable and water tolerance nanocatalyst

    NASA Astrophysics Data System (ADS)

    Khoobi, Mehdi; Delshad, Tayebeh Modiri; Vosooghi, Mohsen; Alipour, Masoumeh; Hamadi, Hosein; Alipour, Eskandar; Hamedani, Majid Pirali; Sadat ebrahimi, Seyed Esmaeil; Safaei, Zahra; Foroumadi, Alireza; Shafiee, Abbas

    2015-02-01

    A novel magnetically separable catalyst was prepared based on surface modification of Fe3O4 magnetic nanoparticle (MNPs) with polyethyleneimine (PEI) via covalent bonding. [3-(2,3-Epoxypropoxy)propyl]trimethoxysilane (EPO) was used as cross linker to bond PEI on the surface of MNPs with permanent stability in contrast to PEI coating via electrostatic interactions. The synthesized catalyst was characterized by Fourier transform infrared (FT-IR), thermogravimetric analysis (TGA), X-ray powder diffraction (XRD), transmission electron microscopy (TEM) and vibrating sample magnetometry (VSM). The catalyst show high efficiency for one-pot synthesis of 2-amino-3-cyano-4H-pyran derivatives via multi-component reaction (MCR). This procedure offers the advantages of green reaction media, high yield, short reaction time, easy purification of the products and simple recovery and reuse of the catalyst by simple magnetic decantation without significant loss of catalytic activity.

  20. Enhanced Impurity-Free Intermixing Bandgap Engineering for InP-Based Photonic Integrated Circuits

    NASA Astrophysics Data System (ADS)

    Cui, Xiao; Zhang, Can; Liang, Song; Zhu, Hong-Liang; Hou, Lian-Ping

    2014-04-01

    Impurity-free intermixing of InGaAsP multiple quantum wells (MQW) using sputtering Cu/SiO2 layers followed by rapid thermal processing (RTP) is demonstrated. The bandgap energy could be modulated by varying the sputtering power and time of Cu, RTP temperature and time to satisfy the demands for lasers, modulators, photodetector, and passive waveguides for the photonic integrated circuits with a simple procedure. The blueshift of the bandgap wavelength of MQW is experimentally investigated on different sputtering and annealing conditions. It is obvious that the introduction of the Cu layer could increase the blueshift more greatly than the common impurity free vacancy disordering technique. A maximum bandgap blueshift of 172 nm is realized with an annealing condition of 750°C and 200s. The improved technique is promising for the fabrication of the active/passive optoelectronic components on a single wafer with simple process and low cost.

  1. Numerical techniques for the solution of the compressible Navier-Stokes equations and implementation of turbulence models. [separated turbulent boundary layer flow problems

    NASA Technical Reports Server (NTRS)

    Baldwin, B. S.; Maccormack, R. W.; Deiwert, G. S.

    1975-01-01

    The time-splitting explicit numerical method of MacCormack is applied to separated turbulent boundary layer flow problems. Modifications of this basic method are developed to counter difficulties associated with complicated geometry and severe numerical resolution requirements of turbulence model equations. The accuracy of solutions is investigated by comparison with exact solutions for several simple cases. Procedures are developed for modifying the basic method to improve the accuracy. Numerical solutions of high-Reynolds-number separated flows over an airfoil and shock-separated flows over a flat plate are obtained. A simple mixing length model of turbulence is used for the transonic flow past an airfoil. A nonorthogonal mesh of arbitrary configuration facilitates the description of the flow field. For the simpler geometry associated with the flat plate, a rectangular mesh is used, and solutions are obtained based on a two-equation differential model of turbulence.

  2. SCEW: a Microsoft Excel add-in for easy creation of survival curves.

    PubMed

    Khan, Haseeb Ahmad

    2006-07-01

    Survival curves are frequently used for reporting survival or mortality outcomes of experimental pharmacological/toxicological studies and of clinical trials. Microsoft Excel is a simple and widely used tool for creation of numerous types of graphic presentations however it is difficult to create step-wise survival curves in Excel. Considering the familiarity of clinicians and biomedical scientists with Excel, an algorithm survival curves in Excel worksheet (SCEW) has been developed for easy creation of survival curves directly in Excel worksheets. The algorithm has been integrated in the form of Excel add-in for easy installation and usage. The program is based on modification of frequency data for binary break-up using the spreadsheet formula functions whereas a macro subroutine automates the creation of survival curves. The advantages of this program are simple data input, minimal procedural steps and the creation of survival curves in the familiar confines of Excel.

  3. Amelioration of ischemic brain damage by peritoneal dialysis

    PubMed Central

    Godino, María del Carmen; Romera, Victor G.; Sánchez-Tomero, José Antonio; Pacheco, Jesus; Canals, Santiago; Lerma, Juan; Vivancos, José; Moro, María Angeles; Torres, Magdalena; Lizasoain, Ignacio; Sánchez-Prieto, José

    2013-01-01

    Ischemic stroke is a devastating condition, for which there is still no effective therapy. Acute ischemic stroke is associated with high concentrations of glutamate in the blood and interstitial brain fluid. The inability of the tissue to retain glutamate within the cells of the brain ultimately provokes neuronal death. Increased concentrations of interstitial glutamate exert further excitotoxic effects on healthy tissue surrounding the infarct zone. We developed a strategy based on peritoneal dialysis to reduce blood glutamate levels, thereby accelerating brain-to-blood glutamate clearance. In a rat model of stroke, this simple procedure reduced the transient increase in glutamate, consequently decreasing the size of the infarct area. Functional magnetic resonance imaging demonstrated that the rescued brain tissue remained functional. Moreover, in patients with kidney failure, peritoneal dialysis significantly decreased glutamate concentrations. Our results suggest that peritoneal dialysis may represent a simple and effective intervention for human stroke patients. PMID:23999426

  4. Computing multiple periodic solutions of nonlinear vibration problems using the harmonic balance method and Groebner bases

    NASA Astrophysics Data System (ADS)

    Grolet, Aurelien; Thouverez, Fabrice

    2015-02-01

    This paper is devoted to the study of vibration of mechanical systems with geometric nonlinearities. The harmonic balance method is used to derive systems of polynomial equations whose solutions give the frequency component of the possible steady states. Groebner basis methods are used for computing all solutions of polynomial systems. This approach allows to reduce the complete system to an unique polynomial equation in one variable driving all solutions of the problem. In addition, in order to decrease the number of variables, we propose to first work on the undamped system, and recover solution of the damped system using a continuation on the damping parameter. The search for multiple solutions is illustrated on a simple system, where the influence of the retained number of harmonic is studied. Finally, the procedure is applied on a simple cyclic system and we give a representation of the multiple states versus frequency.

  5. How critical cost analysis can save money in today’s NHS: a review of carpal tunnel surgery in a district general hospital

    PubMed Central

    Williamson, Mark; Sehjal, Ranjit; Jones, Mark; James, Chris; Smith, Andrew

    2018-01-01

    With today’s National Health Service (NHS) facing huge financial pressures the healthcare profession cannot afford to carry on spending at the current rate. Individual clinicians should be encouraged to critically appraise their own practices to bring about a more efficient and cost-effective service. The purpose of this project was to analyse the way that carpal tunnel surgery was being performed within our institution and bring about safe changes to practice that reduce expenditure. By critiquing our practices and applying simple changes based around sound evidence an annual saving of over £15 500 to the department was made. The changes instigated are simple, sustainable and safe to implement while providing improved patient satisfaction. They are also easily transferrable across institutions and to other minor hand surgical procedures to afford even greater ongoing savings to the NHS. PMID:29946571

  6. How critical cost analysis can save money in today's NHS: a review of carpal tunnel surgery in a district general hospital.

    PubMed

    Williamson, Mark; Sehjal, Ranjit; Jones, Mark; James, Chris; Smith, Andrew

    2018-01-01

    With today's National Health Service (NHS) facing huge financial pressures the healthcare profession cannot afford to carry on spending at the current rate. Individual clinicians should be encouraged to critically appraise their own practices to bring about a more efficient and cost-effective service. The purpose of this project was to analyse the way that carpal tunnel surgery was being performed within our institution and bring about safe changes to practice that reduce expenditure. By critiquing our practices and applying simple changes based around sound evidence an annual saving of over £15 500 to the department was made. The changes instigated are simple, sustainable and safe to implement while providing improved patient satisfaction. They are also easily transferrable across institutions and to other minor hand surgical procedures to afford even greater ongoing savings to the NHS.

  7. Teaching Simulation and Computer-Aided Separation Optimization in Liquid Chromatography by Means of Illustrative Microsoft Excel Spreadsheets

    ERIC Educational Resources Information Center

    Fasoula, S.; Nikitas, P.; Pappa-Louisi, A.

    2017-01-01

    A series of Microsoft Excel spreadsheets were developed to simulate the process of separation optimization under isocratic and simple gradient conditions. The optimization procedure is performed in a stepwise fashion using simple macros for an automatic application of this approach. The proposed optimization approach involves modeling of the peak…

  8. SIMPLE SAMPLE CLEAN UP PROCEDURE AND HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD FOR THE ANALYSIS OF CYANURIC ACID IN HUMAN URINE

    EPA Science Inventory

    Cyanuric acide (CA) is widely used as a chlorine stabilizer in outdoor pools. No simple method exists for CA measurement in the urine of exposed swimmers. The high hydrophilicity of CA makes usage of solid phase sorbents to extract it from urine nearly impossible because of samp...

  9. Quantifying characteristic growth dynamics in a semiarid grassland ecosystem by predicting short-term NDVI phenology from daily rainfall: a simple 4 parameter coupled-reservoir model

    USDA-ARS?s Scientific Manuscript database

    Predicting impacts of the magnitude and seasonal timing of rainfall pulses in water-limited grassland ecosystems concerns ecologists, climate scientists, hydrologists, and a variety of stakeholders. This report describes a simple, effective procedure to emulate the seasonal response of grassland bio...

  10. Improved Holistic Analysis of Rayleigh Waves for Single- and Multi-Offset Data: Joint Inversion of Rayleigh-Wave Particle Motion and Vertical- and Radial-Component Velocity Spectra

    NASA Astrophysics Data System (ADS)

    Dal Moro, Giancarlo; Moustafa, Sayed S. R.; Al-Arifi, Nassir S.

    2018-01-01

    Rayleigh waves often propagate according to complex mode excitation so that the proper identification and separation of specific modes can be quite difficult or, in some cases, just impossible. Furthermore, the analysis of a single component (i.e., an inversion procedure based on just one objective function) necessarily prevents solving the problems related to the non-uniqueness of the solution. To overcome these issues and define a holistic analysis of Rayleigh waves, we implemented a procedure to acquire data that are useful to define and efficiently invert the three objective functions defined from the three following "objects": the velocity spectra of the vertical- and radial-components and the Rayleigh-wave particle motion (RPM) frequency-offset data. Two possible implementations are presented. In the first case we consider classical multi-offset (and multi-component) data, while in a second possible approach we exploit the data recorded by a single three-component geophone at a fixed offset from the source. Given the simple field procedures, the method could be particularly useful for the unambiguous geotechnical exploration of large areas, where more complex acquisition procedures, based on the joint acquisition of Rayleigh and Love waves, would not be economically viable. After illustrating the different kinds of data acquisition and the data processing, the results of the proposed methodology are illustrated in a case study. Finally, a series of theoretical and practical aspects are discussed to clarify some issues involved in the overall procedure (data acquisition and processing).

  11. Determination of Aspartame and Caffeine in Carbonated Beverages Utilizing Electrospray Ionization-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bergen, H. Robert, III; Benson, Linda M.; Naylor, Stephen

    2000-10-01

    Mass spectrometry has undergone considerable changes in the past decade. The advent of "soft ionization" techniques such as electrospray ionization (ESI) affords the direct analysis of very polar molecules without need for the complex inefficient derivatization procedures often required in GC-MS. These ionization techniques make possible the direct mass spectral analysis of polar nonvolatile molecules such as DNA and proteins, which previously were difficult or impossible to analyze by MS. Compounds that readily take on a charge (acids and bases) lend themselves to ESI-MS analysis, whereas compounds that do not readily accept a charge (e.g. sugars) are often not seen or are seen only as inefficient adducts (e.g., M+Na+). To gain exposure to this state-of-the-art analytical procedure, high school students utilize ESI-MS in an analysis of aspartame and caffeine. They dilute a beverage sample and inject the diluted sample into the ESI-MS. The lab is procedurally simple and the results clearly demonstrate the potential and limitations of ESI-coupled mass spectrometry. Depending upon the instructional goals, the outlined procedures can be used to quantify the content of caffeine and aspartame in beverages or to understand the capabilities of electrospray ionization.

  12. Evaluation of interlayer interfacial stiffness and layer wave velocity of multilayered structures by ultrasonic spectroscopy.

    PubMed

    Ishii, Yosuke; Biwa, Shiro

    2014-07-01

    An ultrasonic evaluation procedure for the interlayer interfacial normal stiffness and the intralayer longitudinal wave velocity of multilayered plate-like structures is proposed. Based on the characteristics of the amplitude reflection spectrum of ultrasonic wave at normal incidence to a layered structure with spring-type interlayer interfaces, it is shown that the interfacial normal stiffness and the longitudinal wave velocity in the layers can be simultaneously evaluated from the frequencies of local maxima and minima of the spectrum provided that all interfaces and layers have the same properties. The effectiveness of the proposed procedure is investigated from the perspective of the sensitivity of local extremal frequencies of the reflection spectrum. The feasibility of the proposed procedure is also investigated when the stiffness of each interface is subjected to small random fluctuations about a certain average value. The proposed procedure is applied to a 16-layered cross-ply carbon-fiber-reinforced composite laminate. The normal stiffness of resin-rich interfaces and the longitudinal wave velocity of plies in the thickness direction evaluated from the experimental reflection spectrum are shown to be consistent with simple theoretical estimations.

  13. Experimental determination of frequency response function estimates for flexible joint industrial manipulators with serial kinematics

    NASA Astrophysics Data System (ADS)

    Saupe, Florian; Knoblach, Andreas

    2015-02-01

    Two different approaches for the determination of frequency response functions (FRFs) are used for the non-parametric closed loop identification of a flexible joint industrial manipulator with serial kinematics. The two applied experiment designs are based on low power multisine and high power chirp excitations. The main challenge is to eliminate disturbances of the FRF estimates caused by the numerous nonlinearities of the robot. For the experiment design based on chirp excitations, a simple iterative procedure is proposed which allows exploiting the good crest factor of chirp signals in a closed loop setup. An interesting synergy of the two approaches, beyond validation purposes, is pointed out.

  14. Object Classification Based on Analysis of Spectral Characteristics of Seismic Signal Envelopes

    NASA Astrophysics Data System (ADS)

    Morozov, Yu. V.; Spektor, A. A.

    2017-11-01

    A method for classifying moving objects having a seismic effect on the ground surface is proposed which is based on statistical analysis of the envelopes of received signals. The values of the components of the amplitude spectrum of the envelopes obtained applying Hilbert and Fourier transforms are used as classification criteria. Examples illustrating the statistical properties of spectra and the operation of the seismic classifier are given for an ensemble of objects of four classes (person, group of people, large animal, vehicle). It is shown that the computational procedures for processing seismic signals are quite simple and can therefore be used in real-time systems with modest requirements for computational resources.

  15. Orbit dynamics and geographical coverage capabilities of satellite-based solar occultation experiments for global monitoring of stratospheric constituents

    NASA Technical Reports Server (NTRS)

    Brooks, D. R.

    1980-01-01

    Orbit dynamics of the solar occultation technique for satellite measurements of the Earth's atmosphere are described. A one-year mission is simulated and the orbit and mission design implications are discussed in detail. Geographical coverage capabilities are examined parametrically for a range of orbit conditions. The hypothetical mission is used to produce a simulated one-year data base of solar occultation measurements; each occultation event is assumed to produce a single number, or 'measurement' and some statistical properties of the data set are examined. A simple model is fitted to the data to demonstrate a procedure for examining global distributions of atmospheric constitutents with the solar occultation technique.

  16. A Simple Visual Ethanol Biosensor Based on Alcohol Oxidase Immobilized onto Polyaniline Film for Halal Verification of Fermented Beverage Samples

    PubMed Central

    Kuswandi, Bambang; Irmawati, Titi; Hidayat, Moch Amrun; Jayus; Ahmad, Musa

    2014-01-01

    A simple visual ethanol biosensor based on alcohol oxidase (AOX) immobilised onto polyaniline (PANI) film for halal verification of fermented beverage samples is described. This biosensor responds to ethanol via a colour change from green to blue, due to the enzymatic reaction of ethanol that produces acetaldehyde and hydrogen peroxide, when the latter oxidizes the PANI film. The procedure to obtain this biosensor consists of the immobilization of AOX onto PANI film by adsorption. For the immobilisation, an AOX solution is deposited on the PANI film and left at room temperature until dried (30 min). The biosensor was constructed as a dip stick for visual and simple use. The colour changes of the films have been scanned and analysed using image analysis software (i.e., ImageJ) to study the characteristics of the biosensor's response toward ethanol. The biosensor has a linear response in an ethanol concentration range of 0.01%–0.8%, with a correlation coefficient (r) of 0.996. The limit detection of the biosensor was 0.001%, with reproducibility (RSD) of 1.6% and a life time up to seven weeks when stored at 4 °C. The biosensor provides accurate results for ethanol determination in fermented drinks and was in good agreement with the standard method (gas chromatography) results. Thus, the biosensor could be used as a simple visual method for ethanol determination in fermented beverage samples that can be useful for Muslim community for halal verification. PMID:24473284

  17. Simple office-based behavioral approach to patients with chronic belching.

    PubMed

    Katzka, D A

    2013-08-01

    Chronic belching can be a difficult and socially disabling symptom often attributed to reflux with poor response to therapy. In patients where aerophagia is identified as a clear cause, treatment with baclofen may not be tolerated, and biofeedback therapy is time-intensive and may still not be effective. In this pilot study, an office-based easy-to-perform method based on sustained glottal opening was used in five patients with chronic belching, in whom reflux and other causes had been excluded. Treatment consisted of having the patient breathe slowly and diaphragmatically with his or her mouth open during supine, then sitting periods to prevent belching. When this was successful, patients were then counseled on continuing this breathing with mouth slightly ajar as an outpatient using this persistently. Wide mouth opening was used for rescue therapy of belching attacks. All five patients responded to the office-based therapy with complete cessation of belching during the visit. At 1-month follow up, four patients remained asymptomatic. One patient was asymptomatic but for two breakthrough attacks easily managed with the protocol. A simple office-based procedure based on complete glottal opening can be curative for a subset of patients with chronic eructation secondary to repetitive air swallowing. © 2012 Copyright the Author. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  18. Use of a Modified Chaining Procedure with Textual Prompts to Establish Intraverbal Storytelling

    ERIC Educational Resources Information Center

    Valentino, Amber L.; Conine, Daniel E.; Delfs, Caitlin H.; Furlow, Christopher M.

    2015-01-01

    Echoic, tact, and textual transfer procedures have been proven successful in establishing simple intraverbals (Braam and Poling "Applied Research in Mental Retardation," 4, 279-302, 1983; Luciano "Applied Research in Mental Retardation," 102, 346-357, 1986; Watkins et al. "The Analysis of Verbal Behavior," 7, 69-81,…

  19. A pebble count procedure for assessing watershed cumulative effects

    Treesearch

    Gregory S. Bevenger; Rudy M. King

    1995-01-01

    Land mangement activities can result in the delivery of fine sediment to streams. Over time, such delivery can lead to cumulative impacts to the aquactic ecosystem. Because numerous laws require Federal land managers to analyze watershed cumulative effects, field personnel need simple monitoring procedures that can be used directly and consistently. One approach to...

  20. Psychological Distance to Reward: Effects of S+ Duration and the Delay Reduction It Signals

    ERIC Educational Resources Information Center

    Alessandri, Jerome; Stolarz-Fantino, Stephanie; Fantino, Edmund

    2011-01-01

    A concurrent-chains procedure was used to examine choice between segmented (two-component chained schedules) and unsegmented schedules (simple schedules) in terminal links with equal inter-reinforcement intervals. Previous studies using this kind of experimental procedure showed preference for unsegmented schedules for both pigeons and humans. In…

  1. Measuring Slit Width and Separation in a Diffraction Experiment

    ERIC Educational Resources Information Center

    Gan, K. K.; Law, A. T.

    2009-01-01

    We present a procedure for measuring slit width and separation in single- and double-slit diffraction experiments. Intensity spectra of diffracted laser light are measured with an optical sensor (PIN diode). Slit widths and separations are extracted by fitting to the measured spectra. We present a simple fitting procedure to account for the…

  2. Sensitivity calculations for iteratively solved problems

    NASA Technical Reports Server (NTRS)

    Haftka, R. T.

    1985-01-01

    The calculation of sensitivity derivatives of solutions of iteratively solved systems of algebraic equations is investigated. A modified finite difference procedure is presented which improves the accuracy of the calculated derivatives. The procedure is demonstrated for a simple algebraic example as well as an element-by-element preconditioned conjugate gradient iterative solution technique applied to truss examples.

  3. Soxhlet Extraction of Caffeine from Beverage Plants

    NASA Astrophysics Data System (ADS)

    Adam, D. J.; Mainwaring, J.; Quigley, Michael N.

    1996-12-01

    A simple procedure is described for the extraction of caffeine from coffee beans or granules, tea leaves, mat leaves, etc. Since dichloromethane and several other hazardous substances are used, the procedure is best performed in a fume hood. Following extraction, melting point determination of the crystalline precipitate establishes its positive identity. Includes 33 references.

  4. Acquisition of Motor and Cognitive Skills through Repetition in Typically Developing Children

    PubMed Central

    Magallón, Sara; Narbona, Juan; Crespo-Eguílaz, Nerea

    2016-01-01

    Background Procedural memory allows acquisition, consolidation and use of motor skills and cognitive routines. Automation of procedures is achieved through repeated practice. In children, improvement in procedural skills is a consequence of natural neurobiological development and experience. Methods The aim of the present research was to make a preliminary evaluation and description of repetition-based improvement of procedures in typically developing children (TDC). Ninety TDC children aged 6–12 years were asked to perform two procedural learning tasks. In an assembly learning task, which requires predominantly motor skills, we measured the number of assembled pieces in 60 seconds. In a mirror drawing learning task, which requires more cognitive functions, we measured time spent and efficiency. Participants were tested four times for each task: three trials were consecutive and the fourth trial was performed after a 10-minute nonverbal interference task. The influence of repeated practice on performance was evaluated by means of the analysis of variance with repeated measures and the paired-sample test. Correlation coefficients and simple linear regression test were used to examine the relationship between age and performance. Results TDC achieved higher scores in both tasks through repetition. Older children fitted more pieces than younger ones in assembling learning and they were faster and more efficient at the mirror drawing learning task. Conclusions These findings indicate that three consecutive trials at a procedural task increased speed and efficiency, and that age affected basal performance in motor-cognitive procedures. PMID:27384671

  5. Acquisition of Motor and Cognitive Skills through Repetition in Typically Developing Children.

    PubMed

    Magallón, Sara; Narbona, Juan; Crespo-Eguílaz, Nerea

    2016-01-01

    Procedural memory allows acquisition, consolidation and use of motor skills and cognitive routines. Automation of procedures is achieved through repeated practice. In children, improvement in procedural skills is a consequence of natural neurobiological development and experience. The aim of the present research was to make a preliminary evaluation and description of repetition-based improvement of procedures in typically developing children (TDC). Ninety TDC children aged 6-12 years were asked to perform two procedural learning tasks. In an assembly learning task, which requires predominantly motor skills, we measured the number of assembled pieces in 60 seconds. In a mirror drawing learning task, which requires more cognitive functions, we measured time spent and efficiency. Participants were tested four times for each task: three trials were consecutive and the fourth trial was performed after a 10-minute nonverbal interference task. The influence of repeated practice on performance was evaluated by means of the analysis of variance with repeated measures and the paired-sample test. Correlation coefficients and simple linear regression test were used to examine the relationship between age and performance. TDC achieved higher scores in both tasks through repetition. Older children fitted more pieces than younger ones in assembling learning and they were faster and more efficient at the mirror drawing learning task. These findings indicate that three consecutive trials at a procedural task increased speed and efficiency, and that age affected basal performance in motor-cognitive procedures.

  6. The effect of music on parental participation during pediatric laceration repair.

    PubMed

    Sobieraj, Gregory; Bhatt, Maala; LeMay, Sylvie; Rennick, Janet; Johnston, Celeste

    2009-12-01

    The purpose of this quasi-experimental study was to test an intervention on the use of music during simple laceration repair to promote parent-led distraction in children aged 1 to 5. Children's songs were broadcast via speakers during laceration repair and parents were encouraged to participate in distracting their child. The proportion of parental participation was determined. Laceration procedures were videotaped and objectively scored using the Procedure Behavior Check List. A total of 57 children participated in the study. There was no difference in parental involvement between the control and intervention groups. When age, sex, and condition were controlled for, distress scores were significantly higher if the father was present in the procedure room than if only the mother was present (43.68 vs. 23.39, t(54) 4.296, p = < 0.001). It was concluded that distress varies with the age of the child and the parent who is present during the procedure. Providing music during simple laceration repair did not increase the proportion of parents who were involved in distraction.

  7. A rapid and simple procedure to detect the presence of MVM in conditioned cell fluids or culture media.

    PubMed

    Chang, A; Havas, S; Borellini, F; Ostrove, J M; Bird, R E

    1997-12-01

    During the manufacture of biopharmaceuticals, numerous adventitious agents have been detected in Master Cell Banks, end-of-production cells as well as bulk harvest fluid. Recently, a number of large-scale production bioreactors have become infected with Minute Virus of Mice (MVM) during cGMP (current good manufacturing practices) operations, and this has resulted in both the loss of product and the need for major cleaning validation procedures to be put in place. We have developed a simple DNA extraction/PCR assay to detect the presence of MVM in cell culture supernatant (conditioned cell fluids). This highly specific assay can detect 10 or fewer genome equivalents (copies) of MVM following PCR and gel electrophoresis visualization. For routine high-throughput detection, 300-100 copies could be consistently detected. The extraction procedure was shown to reliably detect MVM at a concentration of 1 TCID50/ml. The combination of the extraction/PCR procedure establishes a powerful, sensitive, specific assay that can detect the presence of MVM sequences with a 1-day turnaround time.

  8. Prediction of composite thermal behavior made simple

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.

    1981-01-01

    A convenient procedure is described to determine the thermal behavior (thermal expansion coefficients and thermal stresses) of angleplied fiber composites using a pocket calculator. The procedure consists of equations and appropriate graphs for various ( + or - theta) ply combinations. These graphs present reduced stiffness and thermal expansion coefficients as functions of (+ or - theta) in order to simplify and expedite the use of the equations. The procedure is applicable to all types of balanced, symmetric fiber composites including interply and intraply hybrids. The versatility and generality of the procedure is illustrated using several step-by-step numerical examples.

  9. To t-Test or Not to t-Test? A p-Values-Based Point of View in the Receiver Operating Characteristic Curve Framework.

    PubMed

    Vexler, Albert; Yu, Jihnhee

    2018-04-13

    A common statistical doctrine supported by many introductory courses and textbooks is that t-test type procedures based on normally distributed data points are anticipated to provide a standard in decision-making. In order to motivate scholars to examine this convention, we introduce a simple approach based on graphical tools of receiver operating characteristic (ROC) curve analysis, a well-established biostatistical methodology. In this context, we propose employing a p-values-based method, taking into account the stochastic nature of p-values. We focus on the modern statistical literature to address the expected p-value (EPV) as a measure of the performance of decision-making rules. During the course of our study, we extend the EPV concept to be considered in terms of the ROC curve technique. This provides expressive evaluations and visualizations of a wide spectrum of testing mechanisms' properties. We show that the conventional power characterization of tests is a partial aspect of the presented EPV/ROC technique. We desire that this explanation of the EPV/ROC approach convinces researchers of the usefulness of the EPV/ROC approach for depicting different characteristics of decision-making procedures, in light of the growing interest regarding correct p-values-based applications.

  10. The change and development of statistical methods used in research articles in child development 1930-2010.

    PubMed

    Køppe, Simo; Dammeyer, Jesper

    2014-09-01

    The evolution of developmental psychology has been characterized by the use of different quantitative and qualitative methods and procedures. But how does the use of methods and procedures change over time? This study explores the change and development of statistical methods used in articles published in Child Development from 1930 to 2010. The methods used in every article in the first issue of every volume were categorized into four categories. Until 1980 relatively simple statistical methods were used. During the last 30 years there has been an explosive use of more advanced statistical methods employed. The absence of statistical methods or use of simple methods had been eliminated.

  11. Automated processing of dynamic properties of intraventricular pressure by computer program and electronic circuit.

    PubMed

    Adler, D; Mahler, Y

    1980-04-01

    A procedure for automatic detection and digital processing of the maximum first derivative of the intraventricular pressure (dp/dtmax), time to dp/dtmax(t - dp/dt) and beat-to-beat intervals have been developed. The procedure integrates simple electronic circuits with a short program using a simple algorithm for the detection of the points of interest. The tasks of differentiating the pressure signal and detecting the onset of contraction were done by electronics, while the tasks of finding the values of dp/dtmax, t - dp/dt, beat-to-beat intervals and all computations needed were done by software. Software/hardware 'trade off' considerations and the accuracy and reliability of the system are discussed.

  12. Context Switching with Multiple Register Windows: A RISC Performance Study

    NASA Technical Reports Server (NTRS)

    Konsek, Marion B.; Reed, Daniel A.; Watcharawittayakul, Wittaya

    1987-01-01

    Although previous studies have shown that a large file of overlapping register windows can greatly reduce procedure call/return overhead, the effects of register windows in a multiprogramming environment are poorly understood. This paper investigates the performance of multiprogrammed, reduced instruction set computers (RISCs) as a function of window management strategy. Using an analytic model that reflects context switch and procedure call overheads, we analyze the performance of simple, linearly self-recursive programs. For more complex programs, we present the results of a simulation study. These studies show that a simple strategy that saves all windows prior to a context switch, but restores only a single window following a context switch, performs near optimally.

  13. Nephrectomy for benign disease in the UK: results from the British Association of Urological Surgeons nephrectomy database.

    PubMed

    Zelhof, Bachar; McIntyre, Iain G; Fowler, Sarah M; Napier-Hemy, Richard D; Burke, Daniel M; Grey, Ben R

    2016-01-01

    To summarize the practice of UK urologists with regard to nephrectomy for benign disease, documenting the indications, procedural techniques and outcomes. All patients undergoing nephrectomy for a benign condition in 2012 were identified from the British Association of Urological Surgeons (BAUS) nephrectomy database. Recorded variables included the technique of surgery, the type of minimally invasive procedure, operating time, blood loss, transfusion rate, conversion rate, intra- and postoperative complications and mortality rate. Cases were also sub-analysed according to their pathologies to determine the differences in complication rate between stone disease, pyelonephritis, non-functioning kidney and other benign lesions. To contextualize procedural complexity, the simple nephrectomy data were compared with those obtained from the BAUS stage T1 radical nephrectomy audit. A total of 1 093 nephrectomies were performed (537 non-functioning kidneys, 142 stone disease, 129 nephrectomies secondary to pyelonephritis and 285 cases with other benign conditions). Of these, 76% were performed laparoscopically. Blood loss >500 mL was noted in 74 cases with a 4.8% blood transfusion rate. The intra- and postoperative complication rates were 5.2 and 11.9%, respectively. Of the 847 minimally invasive procedures, the conversion rate was 5.9%. Patients with stone disease have the highest intra- and postoperative complications (9.9 and 23.9%, respectively) compared with other benign pathologies. The total number of T1 radical nephrectomies performed was 1 095. In comparison with T1 radical nephrectomy, simple nephrectomy carries an increased risk of conversion to an open procedure (1.8 times), a higher rate of blood transfusion (4.8 vs 2.8%), and a higher risk of intra- and postoperative complications (5.2 vs 3.7% and 11.9 vs 10%, respectively). The present study reports the largest series of nephrectomies performed for benign disease and the resultant data now support the bespoke preoperative counselling of patients. Furthermore, it confirms the commonly held view that simple nephrectomy can be more difficult than its radical counterpart. The authors suggest that the term 'simple nephrectomy' is changed to 'benign nephrectomy'. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  14. Sensing magnetic flux density of artificial neurons with a MEMS device.

    PubMed

    Tapia, Jesus A; Herrera-May, Agustin L; García-Ramírez, Pedro J; Martinez-Castillo, Jaime; Figueras, Eduard; Flores, Amira; Manjarrez, Elías

    2011-04-01

    We describe a simple procedure to characterize a magnetic field sensor based on microelectromechanical systems (MEMS) technology, which exploits the Lorentz force principle. This sensor is designed to detect, in future applications, the spiking activity of neurons or muscle cells. This procedure is based on the well-known capability that a magnetic MEMS device can be used to sense a small magnetic flux density. In this work, an electronic neuron (FitzHugh-Nagumo) is used to generate controlled spike-like magnetic fields. We show that the magnetic flux density generated by the hardware of this neuron can be detected with a new MEMS magnetic field sensor. This microdevice has a compact resonant structure (700 × 600 × 5 μm) integrated by an array of silicon beams and p-type piezoresistive sensing elements, which need an easy fabrication process. The proposed microsensor has a resolution of 80 nT, a sensitivity of 1.2 V.T(-1), a resonant frequency of 13.87 kHz, low power consumption (2.05 mW), quality factor of 93 at atmospheric pressure, and requires a simple signal processing circuit. The importance of our study is twofold. First, because the artificial neuron can generate well-controlled magnetic flux density, we suggest it could be used to analyze the resolution and performance of different magnetic field sensors intended for neurobiological applications. Second, the introduced MEMS magnetic field sensor may be used as a prototype to develop new high-resolution biomedical microdevices to sense magnetic fields from cardiac tissue, nerves, spinal cord, or the brain.

  15. Aligned carbon nanotube, graphene and graphite oxide thin films via substrate-directed rapid interfacial deposition

    NASA Astrophysics Data System (ADS)

    D'Arcy, Julio M.; Tran, Henry D.; Stieg, Adam Z.; Gimzewski, James K.; Kaner, Richard B.

    2012-05-01

    A procedure for depositing thin films of carbon nanostructures is described that overcomes the limitations typically associated with solution based methods. Transparent and conductively continuous carbon coatings can be grown on virtually any type of substrate within seconds. Interfacial surface tension gradients result in directional fluid flow and film spreading at the water/oil interface. Transparent films of carbon nanostructures are produced including aligned ropes of single-walled carbon nanotubes and assemblies of single sheets of chemically converted graphene and graphite oxide. Process scale-up, layer-by-layer deposition, and a simple method for coating non-activated hydrophobic surfaces are demonstrated.A procedure for depositing thin films of carbon nanostructures is described that overcomes the limitations typically associated with solution based methods. Transparent and conductively continuous carbon coatings can be grown on virtually any type of substrate within seconds. Interfacial surface tension gradients result in directional fluid flow and film spreading at the water/oil interface. Transparent films of carbon nanostructures are produced including aligned ropes of single-walled carbon nanotubes and assemblies of single sheets of chemically converted graphene and graphite oxide. Process scale-up, layer-by-layer deposition, and a simple method for coating non-activated hydrophobic surfaces are demonstrated. Electronic supplementary information (ESI) available: Droplet coalescence, catenoid formation, mechanism of film growth, scanning electron micrographs showing carbon nanotube alignment, flexible transparent films of SWCNTs, AFM images of a chemically converted graphene film, and SEM images of SWCNT free-standing thin films. See DOI: 10.1039/c2nr00010e

  16. Redox-iodometry: a new potentiometric method.

    PubMed

    Gottardi, Waldemar; Pfleiderer, Jörg

    2005-07-01

    A new iodometric method for quantifying aqueous solutions of iodide-oxidizing and iodine-reducing substances, as well as plain iodine/iodide solutions, is presented. It is based on the redox potential of said solutions after reaction with iodide (or iodine) of known initial concentration. Calibration of the system and calculations of unknown concentrations was performed on the basis of developed algorithms and simple GWBASIC-programs. The method is distinguished by a short analysis time (2-3 min) and a simple instrumentation consisting of pH/mV meter, platinum and reference electrodes. In general the feasible concentration range encompasses 0.1 to 10(-6) mol/L, although it goes down to 10(-8) mol/L (0.001 mg Cl2/L) for oxidants like active chlorine compounds. The calculated imprecision and inaccuracy of the method were found to be 0.4-0.9% and 0.3-0.8%, respectively, resulting in a total error of 0.5-1.2%. Based on the experiments, average imprecisions of 1.0-1.5% at c(Ox)>10(-5) M, 1.5-3% at 10(-5) to 10(-7) M, and 4-7% at <10(-7) M were found. Redox-iodometry is a simple, precise, and time-saving substitute for the more laborious and expensive iodometric titration method, which, like other well-established colorimetric procedures, is clearly outbalanced at low concentrations; this underlines the practical importance of redox-iodometry.

  17. Effectiveness of the implementation of a simple radiation reduction protocol in the catheterization laboratory.

    PubMed

    Jurado-Román, Alfonso; Sánchez-Pérez, Ignacio; Lozano Ruíz-Poveda, Fernando; López-Lluva, María T; Pinilla-Echeverri, Natalia; Moreno Arciniegas, Andrea; Agudo-Quilez, Pilar; Gil Agudo, Antonio

    2016-01-01

    A reduction in radiation doses at the catheterization laboratory, maintaining the quality of procedures is essential. Our objective was to analyze the results of a simple radiation reduction protocol at a high-volume interventional cardiology unit. We analyzed 1160 consecutive procedures: 580 performed before the implementation of the protocol and 580 after it. The protocol consisted in: the reduction of the number of ventriculographies and aortographies, the optimization of the collimation and the geometry of the X ray tube-patient-receptor, the use of low dose-rate fluoroscopy and the reduction of the number of cine sequences using the software "last fluoroscopy hold". There were no significant differences in clinical baseline features or in the procedural characteristics with the exception of a higher percentage of radial approach (30.7% vs 69.6%; p<0.001) and of percutaneous coronary interventions of chronic total occlusions after the implementation of the protocol (2.1% vs 6.7%; p=0,001). Angiographic success was similar during both periods (98.3% vs 99.2%; p=0.2). There were no significant differences between both periods regarding the overall duration of the procedures (26.9 vs 29.6min; p=0.14), or the fluoroscopy time (13.3 vs 13.2min; p=0.8). We observed a reduction in the percentage of procedures with ventriculography (80.9% vs 7.1%; p<0.0001) or aortography (15.4% vs 4.4%; p<0.0001), the cine runs (21.8 vs 6.9; p<0.0001) and the dose-area product (165 vs 71 Gyxcm(2); p<0.0001). With the implementation of a simple radiation reduction protocol, a 57% reduction of dose-area product was observed without a reduction in the quality or the complexity of procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Anaesthesia for bronchoscopy

    PubMed Central

    Chadha, Meenu; Kulshrestha, Mayank; Biyani, Alok

    2015-01-01

    Bronchoscopy as an investigation or therapeutic procedure demands anaesthesiologist to act accordingly. The present review will take the reader from rigid to fibreoptic flexible bronchoscopy. These procedures are now done as day care procedures in the operation theatre or in critical care units. Advantages and limitations of both rigid and flexible bronchoscopy are analysed. Recently, conscious sedation has come up as the commonly used anaesthetic technique for simple bronchoscopic procedures. However, general anaesthesia still remains a standard technique for more complex procedures. New advances in the field of anaesthesiology such as use of short acting opioids, use of newer drugs such as dexmedetomidine, supraglottic airways and mechanical jet ventilators have facilitated and eased the conduct of the procedure. PMID:26556915

  19. Evaluation of IOTA Simple Ultrasound Rules to Distinguish Benign and Malignant Ovarian Tumours.

    PubMed

    Garg, Sugandha; Kaur, Amarjit; Mohi, Jaswinder Kaur; Sibia, Preet Kanwal; Kaur, Navkiran

    2017-08-01

    IOTA stands for International Ovarian Tumour Analysis group. Ovarian cancer is one of the common cancers in women and is diagnosed at later stage in majority. The limiting factor for early diagnosis is lack of standardized terms and procedures in gynaecological sonography. Introduction of IOTA rules has provided some consistency in defining morphological features of ovarian masses through a standardized examination technique. To evaluate the efficacy of IOTA simple ultrasound rules in distinguishing benign and malignant ovarian tumours and establishing their use as a tool in early diagnosis of ovarian malignancy. A hospital based case control prospective study was conducted. Patients with suspected ovarian pathology were evaluated using IOTA ultrasound rules and designated as benign or malignant. Findings were correlated with histopathological findings. Collected data was statistically analysed using chi-square test and kappa statistical method. Out of initial 55 patients, 50 patients were included in the final analysis who underwent surgery. IOTA simple rules were applicable in 45 out of these 50 patients (90%). The sensitivity for the detection of malignancy in cases where IOTA simple rules were applicable was 91.66% and the specificity was 84.84%. Accuracy was 86.66%. Classifying inconclusive cases as malignant, the sensitivity and specificity was 93% and 80% respectively. High level of agreement was found between USG and histopathological diagnosis with Kappa value as 0.323. IOTA simple ultrasound rules were highly sensitive and specific in predicting ovarian malignancy preoperatively yet being reproducible, easy to train and use.

  20. A Precise, Simple, and Low-Cost Experiment to Determine the Isobaric Expansion Coefficient for Physical Chemistry Students

    ERIC Educational Resources Information Center

    Pe´rez, Eduardo

    2015-01-01

    The procedure of a physical chemistry experiment for university students must be designed in a way that the accuracy and precision of the measurements is properly maintained. However, in many cases, that requires costly and sophisticated equipment not readily available in developing countries. A simple, low-cost experiment to determine isobaric…

  1. Standardization of Code on Dental Procedures

    DTIC Science & Technology

    1992-02-13

    oral hard and soft tissues using a periodontal probe, mirror, and explorer, and bitewing, panoramic, or other radiographs as...of living tissue or inert material into periodontal osseous defects to regenerate new periodontal attachment (bone, periodontal ligament, and cementum...Simple (up to 5 cm). Repair and/or suturing of simple to moderately complicated wounds of facial and/or oral soft tissues . 7211 1.8 Repair

  2. A SIMPLE AND RAPID METHOD FOR THE SIMULTANEOUS DETERMINATION OF CALCIUM AND MAGNESIUM FROM THE SAME SAMPLE OF BLOOD SERUM

    PubMed Central

    Kovács, G. S.; Tárnoky, K. E.

    1960-01-01

    A simple and rapid procedure has been developed for the complexometric titration of serum calcium and magnesium using “plasmocorinth B” as indicator. Both determinations can be carried out from the same 0.5 ml. sample. The method is in good agreement with the established calcium and magnesium methods. PMID:14411396

  3. Evaluation of a novel semi-automated HPLC procedure for whole blood cyclosporin A confirms equivalence to adjusted monoclonal values from Abbott TDx.

    PubMed

    Roberts, Norman B; Dutton, John; Higgins, Gerald; Allars, Lesley

    2005-01-01

    The problem in the measurement of cyclosporin (CyA) is that the widely used immuno-based assays suffer from interference by metabolites present in unpredictable excess. To resolve this, the consensus view has been to develop more specific and robust procedures for the measurement of CyA alone in order to give values similar to those obtained by HPLC. We developed an alternative strategy based on Abbott poly- and monoclonal assays to derive an adjusted monoclonal value as an equivalent measurement to HPLC. We have now evaluated a recently developed semi-automated HPLC procedure and used it to test the validity of the adjusted monoclonal value. The automated HPLC procedure with online clean-up was optimised for the separation of CyA and internal standard CyD. The assay was simple to use, precise and gave good recovery of cyclosporin from whole blood. Comparisons with the more specific immunoassays Abbott AxSym and EMIT showed close agreement, whereas Abbott monoclonal values indicated up to 20% positive bias. In contrast, the adjusted monoclonal values gave good agreement with HPLC. Data obtained from HPLC linked to tandem mass spectrometry (MS) indicated closer agreement with Abbott monoclonal values than expected, suggesting some positive bias with MS. The benefit of using an adjusted monoclonal value is that a result equivalent to HPLC is obtained, as well as an indication of the concentration of metabolites from the Abbott polyclonal measurement.

  4. Efficiency of endoscopy units can be improved with use of discrete event simulation modeling.

    PubMed

    Sauer, Bryan G; Singh, Kanwar P; Wagner, Barry L; Vanden Hoek, Matthew S; Twilley, Katherine; Cohn, Steven M; Shami, Vanessa M; Wang, Andrew Y

    2016-11-01

    Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience.

  5. Efficiency of endoscopy units can be improved with use of discrete event simulation modeling

    PubMed Central

    Sauer, Bryan G.; Singh, Kanwar P.; Wagner, Barry L.; Vanden Hoek, Matthew S.; Twilley, Katherine; Cohn, Steven M.; Shami, Vanessa M.; Wang, Andrew Y.

    2016-01-01

    Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience. PMID:27853739

  6. Experimental calibration procedures for rotating Lorentz-force flowmeters

    DOE PAGES

    Hvasta, M. G.; Slighton, N. T.; Kolemen, E.; ...

    2017-07-14

    Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.

  7. Experimental calibration procedures for rotating Lorentz-force flowmeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hvasta, M. G.; Slighton, N. T.; Kolemen, E.

    Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.

  8. Fecal Fistula Communicating with a Femur Shaft Fracture Secondary to a Malpositioned Suprapubic Catheter: A Case Report

    PubMed Central

    Guled, Uday; Goni, Vijay G.; Honnurappa, Arjun R.H.; John, Rakesh; Vardhana, Harsha; Sharma, Gaurav; Pattabhiraman, Kirubakaran S.

    2015-01-01

    Patient: Male, 18 Final Diagnosis: Fecal fistula communicating with fracture shaft femur secondary to malpositioned SPC Symptoms: — Medication: — Clinical Procedure: Advertisement and rail fixator application Specialty: Orthopedics and Trauamtology Objective: Diagnostic/therapeutic accidents Background: Suprapubic catheter (SPC) insertion is a common urological procedure. Though considered a simple and safe procedure, complications are bound to occur if proper precautions are not taken during the procedure. The reported complications include gross hematuria, post-obstruction diuresis, insertion site skin-related complications, and intra-abdominal visceral injuries. Iatrogenic bowel injuries have been reported to occur as a complication in around 2.5% of cases. Case Report: We report a very rare case of a bowel injury due to improper insertion of a SPC leading to fecal matter tracking along the muscle planes to reach the fracture site of the femur shaft and formation of an external fecal fistula along the lateral aspect of thigh, which according to us is the first reported case in the literature. Conclusions: This case report shows the devastating complication of a technically simple procedure done in an improper manner and successful management of a rare case of femur fracture with communicating fecal fistula. The purpose of this case report is to highlight the importance of taking proper precautions before the procedure. PMID:26439133

  9. Efficient generation of sum-of-products representations of high-dimensional potential energy surfaces based on multimode expansions

    NASA Astrophysics Data System (ADS)

    Ziegler, Benjamin; Rauhut, Guntram

    2016-03-01

    The transformation of multi-dimensional potential energy surfaces (PESs) from a grid-based multimode representation to an analytical one is a standard procedure in quantum chemical programs. Within the framework of linear least squares fitting, a simple and highly efficient algorithm is presented, which relies on a direct product representation of the PES and a repeated use of Kronecker products. It shows the same scalings in computational cost and memory requirements as the potfit approach. In comparison to customary linear least squares fitting algorithms, this corresponds to a speed-up and memory saving by several orders of magnitude. Different fitting bases are tested, namely, polynomials, B-splines, and distributed Gaussians. Benchmark calculations are provided for the PESs of a set of small molecules.

  10. Efficient generation of sum-of-products representations of high-dimensional potential energy surfaces based on multimode expansions.

    PubMed

    Ziegler, Benjamin; Rauhut, Guntram

    2016-03-21

    The transformation of multi-dimensional potential energy surfaces (PESs) from a grid-based multimode representation to an analytical one is a standard procedure in quantum chemical programs. Within the framework of linear least squares fitting, a simple and highly efficient algorithm is presented, which relies on a direct product representation of the PES and a repeated use of Kronecker products. It shows the same scalings in computational cost and memory requirements as the potfit approach. In comparison to customary linear least squares fitting algorithms, this corresponds to a speed-up and memory saving by several orders of magnitude. Different fitting bases are tested, namely, polynomials, B-splines, and distributed Gaussians. Benchmark calculations are provided for the PESs of a set of small molecules.

  11. An efficient algorithm for automatic phase correction of NMR spectra based on entropy minimization

    NASA Astrophysics Data System (ADS)

    Chen, Li; Weng, Zhiqiang; Goh, LaiYoong; Garland, Marc

    2002-09-01

    A new algorithm for automatic phase correction of NMR spectra based on entropy minimization is proposed. The optimal zero-order and first-order phase corrections for a NMR spectrum are determined by minimizing entropy. The objective function is constructed using a Shannon-type information entropy measure. Entropy is defined as the normalized derivative of the NMR spectral data. The algorithm has been successfully applied to experimental 1H NMR spectra. The results of automatic phase correction are found to be comparable to, or perhaps better than, manual phase correction. The advantages of this automatic phase correction algorithm include its simple mathematical basis and the straightforward, reproducible, and efficient optimization procedure. The algorithm is implemented in the Matlab program ACME—Automated phase Correction based on Minimization of Entropy.

  12. Robust control of the DC-DC boost converter based on the uncertainty and disturbance estimator

    NASA Astrophysics Data System (ADS)

    Oucheriah, Said

    2017-11-01

    In this paper, a robust non-linear controller based on the uncertainty and disturbance estimator (UDE) scheme is successfully developed and implemented for the output voltage regulation of the DC-DC boost converter. System uncertainties, external disturbances and unknown non-linear dynamics are lumped as a signal that is accurately estimated using a low-pass filter and their effects are cancelled by the controller. This methodology forms the basis of the UDE-based controller. A simple procedure is also developed that systematically determines the parameters of the controller to meet certain specifications. Using simulation, the effectiveness of the proposed controller is compared against the sliding-mode control (SMC). Experimental tests also show that the proposed controller is robust to system uncertainties, large input and load perturbations.

  13. Total laparoscopic gastropexy using 1 simple continuous barbed suture line in 63 dogs.

    PubMed

    Takacs, Joel D; Singh, Ameet; Case, J Brad; Mayhew, Philipp D; Giuffrida, Michelle A; Caceres, Ana V; Fox-Alvarez, W Alexander; Runge, Jeffrey J

    2017-02-01

    To describe the use and outcome of a single, simple continuous, barbed suture line for prophylactic, total laparoscopic gastropexy in dogs. Multi-center, retrospective case series. Sixty-three client-owned dogs. Medical records of dogs undergoing total laparoscopic gastropexy using a barbed suture at 4 academic veterinary hospitals from 2011-2015 were reviewed. Data collected included signalment, procedure time, procedure-associated complications, short-term complications, and long-term outcome. All procedures were performed under general anesthesia in dorsal to dorsal-left oblique recumbency. Laparoscopic ports were placed on ventral midline in 1 of 3 port configurations, and 5 mm laparoscopic needle drivers were used for intracorporeal sutured gastropexy with unidirectional barbed suture. The gastropexy was positioned just caudal to the 13th rib, 2-4 cm lateral to the rectus abdominis muscle. Sixty-three dogs underwent total laparoscopic gastropexy with a single, simple continuous, barbed suture line. Median gastropexy surgery time was 70 minutes (interquartile range [IQR] 60-90 minutes). One dog sustained splenic laceration from Veress needle penetration during initial abdominal insufflation. Short term (>24 hours to 6 months postoperative) complications included incisional seroma formation (n = 2) and suture reaction (n = 1). Long term (>6 months postoperative) complications included intermittent regurgitation and chronic diarrhea in 1 dog. Fifteen dogs had postoperative ultrasound and all had intact gastropexy sites. Total laparoscopic barbed gastropexy using a single, simple continuous, barbed suture line in dogs is safe and results in an intact gastropexy long term. © 2016 The American College of Veterinary Surgeons.

  14. Bayesian Estimation of the Spatially Varying Completeness Magnitude of Earthquake Catalogs

    NASA Astrophysics Data System (ADS)

    Mignan, A.; Werner, M.; Wiemer, S.; Chen, C.; Wu, Y.

    2010-12-01

    Assessing the completeness magnitude Mc of earthquake catalogs is an essential prerequisite for any seismicity analysis. We employ a simple model to compute Mc in space, based on the proximity to seismic stations in a network. We show that a relationship of the form Mcpred(d) = ad^b+c, with d the distance to the 5th nearest seismic station, fits the observations well. We then propose a new Mc mapping approach, the Bayesian Magnitude of Completeness (BMC) method, based on a 2-step procedure: (1) a spatial resolution optimization to minimize spatial heterogeneities and uncertainties in Mc estimates and (2) a Bayesian approach that merges prior information about Mc based on the proximity to seismic stations with locally observed values weighted by their respective uncertainties. This new methodology eliminates most weaknesses associated with current Mc mapping procedures: the radius that defines which earthquakes to include in the local magnitude distribution is chosen according to an objective criterion and there are no gaps in the spatial estimation of Mc. The method solely requires the coordinates of seismic stations. Here, we investigate the Taiwan Central Weather Bureau (CWB) earthquake catalog by computing a Mc map for the period 1994-2010.

  15. Simple proof of equivalence between adiabatic quantum computation and the circuit model.

    PubMed

    Mizel, Ari; Lidar, Daniel A; Mitchell, Morgan

    2007-08-17

    We prove the equivalence between adiabatic quantum computation and quantum computation in the circuit model. An explicit adiabatic computation procedure is given that generates a ground state from which the answer can be extracted. The amount of time needed is evaluated by computing the gap. We show that the procedure is computationally efficient.

  16. Using a Five-Step Procedure for Inferential Statistical Analyses

    ERIC Educational Resources Information Center

    Kamin, Lawrence F.

    2010-01-01

    Many statistics texts pose inferential statistical problems in a disjointed way. By using a simple five-step procedure as a template for statistical inference problems, the student can solve problems in an organized fashion. The problem and its solution will thus be a stand-by-itself organic whole and a single unit of thought and effort. The…

  17. The DESTIN: Preservice Teachers' Drawings of the Ideal Elementary Science Teacher

    ERIC Educational Resources Information Center

    Mensah, Felicia Moore

    2011-01-01

    The aim of this study is to report findings from the Drawing-Elementary-Science-Teacher-Ideal-Not, or the DESTIN procedure. The study utilizes a simple drawing procedure accompanied by a narrative and discussion for understanding preservice teachers' images of science, science teaching, and the science teacher. Ninety drawings from two sections of…

  18. A Procedure for Evaluating Environmental Impact.

    ERIC Educational Resources Information Center

    Leopold, Luna B.; And Others

    This report contains one of the first procedures available to environmental impact statements. The heart of the system is a matrix which is general enough to be used as a reference checklist or a reminder of the full range of actions and impacts on the environment that may relate to any proposed action. This comparatively simple system is intended…

  19. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification.

    PubMed

    Kouzaki, Yuji; Maeda, Takuya; Sasaki, Hiroaki; Tamura, Shinsuke; Hamamoto, Takaaki; Yuki, Atsushi; Sato, Akinori; Miyahira, Yasushi; Kawana, Akihiko

    2015-01-01

    Bacillus Calmette-Guérin (BCG) is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP) to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64 °C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE) kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE) was up to 1 × 10(3) cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 10(3) cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any clinical situation involving immunocompromised patients because of its convenience, rapidity, and cost effectiveness.

  20. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification

    PubMed Central

    Kouzaki, Yuji; Maeda, Takuya; Sasaki, Hiroaki; Tamura, Shinsuke; Hamamoto, Takaaki; Yuki, Atsushi; Sato, Akinori; Miyahira, Yasushi; Kawana, Akihiko

    2015-01-01

    Bacillus Calmette-Guérin (BCG) is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP) to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64°C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE) kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE) was up to 1 × 103 cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 103 cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any clinical situation involving immunocompromised patients because of its convenience, rapidity, and cost effectiveness. PMID:26208001

  1. Rapid Measurement of Soil Carbon in Rice Paddy Field of Lombok Island Indonesia Using Near Infrared Technology

    NASA Astrophysics Data System (ADS)

    Kusumo, B. H.; Sukartono, S.; Bustan, B.

    2018-02-01

    Measuring soil organic carbon (C) using conventional analysis is tedious procedure, time consuming and expensive. It is needed simple procedure which is cheap and saves time. Near infrared technology offers rapid procedure as it works based on the soil spectral reflectance and without any chemicals. The aim of this research is to test whether this technology able to rapidly measure soil organic C in rice paddy field. Soil samples were collected from rice paddy field of Lombok Island Indonesia, and the coordinates of the samples were recorded. Parts of the samples were analysed using conventional analysis (Walkley and Black) and some other parts were scanned using near infrared spectroscopy (NIRS) for soil spectral collection. Partial Least Square Regression (PLSR) Models were developed using data of soil C analysed using conventional analysis and data from soil spectral reflectance. The models were moderately successful to measure soil C in rice paddy field of Lombok Island. This shows that the NIR technology can be further used to monitor the C change in rice paddy soil.

  2. A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer.

    PubMed

    Pagoulatos, N; Haynor, D R; Kim, Y

    2001-09-01

    We have developed a fast calibration method for computing the position and orientation of 2-D ultrasound (US) images in 3-D space where a position sensor is mounted on the US probe. This calibration is required in the fields of 3-D ultrasound and registration of ultrasound with other imaging modalities. Most of the existing calibration methods require a complex and tedious experimental procedure. Our method is simple and it is based on a custom-built phantom. Thirty N-fiducials (markers in the shape of the letter "N") embedded in the phantom provide the basis for our calibration procedure. We calibrated a 3.5-MHz sector phased-array probe with a magnetic position sensor, and we studied the accuracy and precision of our method. A typical calibration procedure requires approximately 2 min. We conclude that we can achieve accurate and precise calibration using a single US image, provided that a large number (approximately ten) of N-fiducials are captured within the US image, enabling a representative sampling of the imaging plane.

  3. Refractive microlensarray made of silver-halide sensitized gelatin (SHSG) etched by enzyme with SLM-based lithography

    NASA Astrophysics Data System (ADS)

    Guo, Xiaowei; Chen, Mingyong; Zhu, Jianhua; Ma, Yanqin; Du, Jinglei; Guo, Yongkang; Du, Chunlei

    2006-01-01

    A novel method for the fabrication of continuous micro-optical components is presented in this paper. It employs a computer controlled digital-micromirror-device(DMD TM) as a switchable projection mask and silver-halide sensitized gelatin (SHSG) as recording material. By etching SHSG with enzyme solution, the micro-optical components with relief modulation can be generated through special processing procedures. The principles of etching SHSG with enzyme and theoretical analysis for deep etching are also discussed in detail, and the detailed quantitative experiments on the processing procedures are conducted to determine optimum technique parameters. A good linear relationship within a depth range of 4μm was experimentally obtained between exposure dose and relief depth. At last, the microlensarray with 256.8μm radius and 2.572μm depth was achieved. This method is simple, cheap and the aberration in processing procedures can be corrected in the step of designing mask, so it is a practical method to fabricate good continuous profile for low-volume production.

  4. Initial experience with hysteroscopic tubal occlusion (Essure®)

    PubMed Central

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Lippi, Umberto Gazi; Martins, João Alfredo; Lopes, Reginaldo Guedes Coelho

    2016-01-01

    ABSTRACT Objective To evaluate results of early tubal occlusions performed by hysteroscopy (Essure®). Methods This prospective study included 38 patients, 73.7% of them were white, mean age 34.5 years, they have had on average 3 pregnancies and 2.7 of deliveries. A total of 86.8% of patients previously prepared the endometrium. All procedures were carried out at outpatient unit without anesthesia. Results Insertion rate of the device was 100% at a mean time of 4 minutes and 50 seconds. Based on the analogical visual scale, average pain reported was three, and 55.3% of women did not report pain after the procedure. After 3 months, 89.5% of patients were very satisfied with the method. Simple radiographs of the pelvis showed 92.1% of topical devices, and one case of unilateral expulsion had occurred. A four years follow-up did not show failure in the method. Conclusions Tubal occlusion through hysteroscopy at outpatient unit and without anesthesia was a quickly and well-tolerated procedure. No serious complications were seen, the success rate was high, and patients were satisfied. PMID:27462885

  5. Simultaneous influence of Stark effect and excessive line broadening on the Hα line

    NASA Astrophysics Data System (ADS)

    Cvetanović, Nikola; Ivković, Saša S.; Obradović, Bratislav M.; Kuraica, Milorad M.

    2017-12-01

    The aim of this paper is to study the combined influence of the Stark effect and the excessive Doppler broadening on the Balmer alpha line in hydrogen discharges. Since this line is a good candidate for measuring electric field in various types of discharges with different gas compositions, a simple method for field measurement based on polarization spectroscopy is developed, that includes all the excitation mechanisms. To simultaneously test the flexibility of the fitting procedure and investigate the excessive broadening, we applied the fitting procedure on line profiles obtained at a range of conditions from two different discharges. The range of pressures and voltages was examined in an abnormal glow and in dielectric barrier discharge operating with hydrogen gas. The model fitting function was able to respond and follow the change in the line profile caused by the change of conditions. This procedure can therefore be recommended for electric field measurement. Contribution to the "Topical Issue: Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  6. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry

    NASA Astrophysics Data System (ADS)

    Amin, Alaa S.; El-Sharjawy, Abdel-Azeem M.; Kassem, Mohammed A.

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L-1 of Tl(III) with relative standard deviation (RSD) of 1.40% (n = 10). The detection and quantification limits are 150 and 495 ng L-1 using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31 × 107 L mol-1 cm-1 and 0.00156 ng cm-2, respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

  7. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    PubMed

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Tested Demonstrations.

    ERIC Educational Resources Information Center

    Gilbert, George L., Ed.

    1988-01-01

    Describes two demonstrations for college level chemistry courses including: "Electrochemical Cells Using Sodium Silicate" and "A Simple, Vivid Demonstration of Selective Precipitation." Lists materials, preparation, procedures, and precautions. (CW)

  9. Removal of copper(II) from some environmental samples by sorptive-flotation using powdered marble wastes as sorbents and oleic acid as surfactant.

    PubMed

    Ghazy, S E; Samra, S E; Mahdy, A F M; El-Morsy, S M

    2004-11-01

    A simple and economic experimental sorptive -flotation procedure is presented for the removal of copper(II) species from aqueous solutions. It is based on using powdered marble wastes (PMW), which are widespread and inexpensive and may represent an environmental problem, as the effective inorganic sorbent and oleic (HOL) as the surfactant. The main parameters (i.e. initial solution pH, sorbent, surfactant and copper concentrations, stirring times, ionic strength, temperature and the presence of foreign ions) influencing the flotation of PMW and /or Cu(II) were examined. Nearly, 100% of PMW and Cu(II) were removed from aqueous solutions at pH7 after stirring for 10 min and at room temperature, (approximately 25 degrees C). The procedure was successfully applied to recover Cu(II) spiked to some natural water samples. A mechanism for sorption and flotation is suggested.

  10. Hydrophilic chromatographic determination of carnosine, anserine, balenine, creatine, and creatinine.

    PubMed

    Mora, Leticia; Sentandreu, Miguel Angel; Toldrá, Fidel

    2007-06-13

    A new HPLC procedure based on hydrophilic interaction chromatography (HILIC) has been developed for the simultaneous determination of carnosine, anserine, balenine, creatine, and creatinine in meat. This is the first time that HILIC has been directly applied to the study of meat components, having the advantage of not requiring complex cleanup and/or sample derivatization procedures. The chromatographic separation has been developed using a silica column (4.6 x 150 mm, 3 microm), and the proposed methodology is simple, reliable, and fast (<13 min per sample). The method has been validated in terms of linearity, repeatability, reproducibility, and recovery and represents an interesting alternative to methods currently in use for determining the mentioned compounds and other polar substances. The detection limits are 5.64, 8.23, 3.66, 3.99, and 0.06 microg/mL for carnosine, anserine, balenine, creatine, and creatinine, respectively.

  11. Modeling scintillator and WLS fiber signals for fast Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Sánchez, F. A.; Medina-Tanco, G.

    2010-08-01

    In this work we present a fast, robust and flexible procedure to simulate electronic signals of scintillator units: plastic scintillator material embedded with a wavelength shifter optical fiber coupled to a photo-multiplier tube which, in turn, is plugged to a front-end electronic board. The simple rationale behind the simulation chain allows to adapt the procedure to a broad range of detectors based on that kind of units. We show that, in order to produce realistic results, the simulation parameters can be properly calibrated against laboratory measurements and used thereafter as input of the simulations. Simulated signals of atmospheric background cosmic ray muons are presented and their main features analyzed and validated using actual measured data. Conversely, for any given practical application, the present simulation scheme can be used to find an adequate combination of photo-multiplier tube and optical fiber at the prototyping stage.

  12. Optimization and automation of quantitative NMR data extraction.

    PubMed

    Bernstein, Michael A; Sýkora, Stan; Peng, Chen; Barba, Agustín; Cobas, Carlos

    2013-06-18

    NMR is routinely used to quantitate chemical species. The necessary experimental procedures to acquire quantitative data are well-known, but relatively little attention has been applied to data processing and analysis. We describe here a robust expert system that can be used to automatically choose the best signals in a sample for overall concentration determination and determine analyte concentration using all accepted methods. The algorithm is based on the complete deconvolution of the spectrum which makes it tolerant of cases where signals are very close to one another and includes robust methods for the automatic classification of NMR resonances and molecule-to-spectrum multiplets assignments. With the functionality in place and optimized, it is then a relatively simple matter to apply the same workflow to data in a fully automatic way. The procedure is desirable for both its inherent performance and applicability to NMR data acquired for very large sample sets.

  13. Determination of ametryn herbicide by bioassay and gas chromatography-mass spectrometry in analysis of residues in drinking water.

    PubMed

    Queiroz, R H; Lanchote, V L; Bonato, P S; Tozato, E; de Carvalho, D; Gomes, M A; Cerdeira, A L

    1999-06-01

    A simple, rapid and quantitative bioassay method was compared to a gas chromatography/mass spectrometry (GC/MS) procedure for the analysis of ametryn in surface and groundwater. This method was based on the activity of ametryn in inhibiting the growth of the primary root and shoot of germinating letuce, Lactuca sativa L. seed. The procedure was sensitive to 0.01 microgram/l and was applicable from this concentration up to 0.6 microgram/l. Initial surface sterilization of the seed, selection of pregerminated seed of certain root lengths and special equipment are not necessary. So, we concluded that the sensitivity of the bioassay method is compatible with the chromatographic method (GC-MS). However, the study of the correlation between methods suggests that the bioassay should be used only as a screening technique for the evaluation of ametryn residues in water.

  14. Quantum integrability and functional equations

    NASA Astrophysics Data System (ADS)

    Volin, Dmytro

    2010-03-01

    In this thesis a general procedure to represent the integral Bethe Ansatz equations in the form of the Reimann-Hilbert problem is given. This allows us to study in simple way integrable spin chains in the thermodynamic limit. Based on the functional equations we give the procedure that allows finding the subleading orders in the solution of various integral equations solved to the leading order by the Wiener-Hopf technics. The integral equations are studied in the context of the AdS/CFT correspondence, where their solution allows verification of the integrability conjecture up to two loops of the strong coupling expansion. In the context of the two-dimensional sigma models we analyze the large-order behavior of the asymptotic perturbative expansion. Obtained experience with the functional representation of the integral equations allowed us also to solve explicitly the crossing equations that appear in the AdS/CFT spectral problem.

  15. The design of supercritical wings by the use of three-dimensional transonic theory

    NASA Technical Reports Server (NTRS)

    Mann, M. J.

    1979-01-01

    A procedure was developed for the design of transonic wings by the iterative use of three dimensional, inviscid, transonic analysis methods. The procedure was based on simple principles of supersonic flow and provided the designer with a set of guidelines for the systematic alteration of wing profile shapes to achieve some desired pressure distribution. The method was generally applicable to wing design at conditions involving a large region of supercriterical flow. To illustrate the method, it was applied to the design of a wing for a supercritical maneuvering fighter that operates at high lift and transonic Mach number. The wing profiles were altered to produce a large region of supercritical flow which was terminated by a weak shock wave. The spanwise variation of drag of this wing and some principles for selecting the streamwise pressure distribution are also discussed.

  16. Hyperopic photorefractive keratectomy and central islands

    NASA Astrophysics Data System (ADS)

    Gobbi, Pier Giorgio; Carones, Francesco; Morico, Alessandro; Vigo, Luca; Brancato, Rosario

    1998-06-01

    We have evaluated the refractive evolution in patients treated with yhyperopic PRK to assess the extent of the initial overcorrection and the time constant of regression. To this end, the time history of the refractive error (i.e. the difference between achieved and intended refractive correction) has been fitted by means of an exponential statistical model, giving information characterizing the surgical procedure with a direct clinical meaning. Both hyperopic and myopic PRk procedures have been analyzed by this method. The analysis of the fitting model parameters shows that hyperopic PRK patients exhibit a definitely higher initial overcorrection than myopic ones, and a regression time constant which is much longer. A common mechanism is proposed to be responsible for the refractive outcomes in hyperopic treatments and in myopic patients exhibiting significant central islands. The interpretation is in terms of superhydration of the central cornea, and is based on a simple physical model evaluating the amount of centripetal compression in the apical cornea.

  17. Wide-range measurement of thermal effusivity using molybdenum thin film with low thermal conductivity for thermal microscopes

    NASA Astrophysics Data System (ADS)

    Miyake, Shugo; Matsui, Genzou; Ohta, Hiromichi; Hatori, Kimihito; Taguchi, Kohei; Yamamoto, Suguru

    2017-07-01

    Thermal microscopes are a useful technology to investigate the spatial distribution of the thermal transport properties of various materials. However, for high thermal effusivity materials, the estimated values of thermophysical parameters based on the conventional 1D heat flow model are known to be higher than the values of materials in the literature. Here, we present a new procedure to solve the problem which calculates the theoretical temperature response with the 3D heat flow and measures reference materials which involve known values of thermal effusivity and heat capacity. In general, a complicated numerical iterative method and many thermophysical parameters are required for the calculation in the 3D heat flow model. Here, we devised a simple procedure by using a molybdenum (Mo) thin film with low thermal conductivity on the sample surface, enabling us to measure over a wide thermal effusivity range for various materials.

  18. Hypopharyngeal reconstruction using a circular stapler.

    PubMed

    Schultz, P; Dupret-Bories, A; Ciftci, S; Fath, L

    2018-02-01

    Distal anastomosis by tubed free flap is one of the main technical difficulties encountered during hypopharyngeal reconstruction. Although high flap survival probability can be achieved by experienced surgical teams, two complications are commonly observed at the flap-oesophagus junction: fistula and stenosis. Use of a circular stapler reduced the frequency of these complications by ensuring a perfectly circular and resistant suture line. Salivary stent placement is therefore unnecessary, allowing earlier resumption of feeding. The stapling procedure is simple, but a few technical skills are required, as the stapler is not specifically designed for this purpose. We describe the indications, surgical procedure and global results based on our series. We consider the forearm flap to be the gold standard for this reconstruction, but thicker flaps, such as pectoralis major flap, can also be used, but with poorer results in terms of healing and swallowing performance. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  19. Evidence-based practice guidelines: a survey of subcutaneous dexamethasone administration.

    PubMed

    Walker, Jackie; Lane, Pauline; McKenzie, Clare

    2010-10-01

    Searching for good evidence to develop clinical practice guidelines can be challenging, as research may not be published or available. A simple question set the authors on a journey to find evidence related to the nursing administration of subcutaneous dexamethasone in the palliative setting. This article outlines the search for evidence and discusses the survey results to gather expert opinion about the nursing administration of dexamethasone. Survey results indicated that only 39% of community services gave dexamethasone via a bolus injection and 88% gave it via a continuous infusion, mainly for site preservation. The diluents used were water for injection or normal saline. Many procedural aspects were supported by current guidelines, with several services using the New Zealand Waitemata District Health Board's (2008) clinical guidelines. Developing and implementing procedural recommendations for nurses to administer this subcutaneous medication will form the next stage of the project.

  20. Comparison between prediction and experiment for all-movable wing and body combinations at supersonic speeds : lift, pitching moment, and hinge moment

    NASA Technical Reports Server (NTRS)

    Nielsen, Jack N; Kaattari, George E; Drake, William C

    1952-01-01

    A simple method is presented for estimating lift, pitching-moment, and hinge-moment characteristics of all-movable wings in the presence of a body as well as the characteristics of wing-body combinations employing such wings. In general, good agreement between the method and experiment was obtained for the lift and pitching moment of the entire wing-body combination and for the lift of the wing in the presence of the body. The method is valid for moderate angles of attack, wing deflection angles, and width of gap between wing and body. The method of estimating hinge moment was not considered sufficiently accurate for triangular all-movable wings. An alternate procedure is proposed based on the experimental moment characteristics of the wing alone. Further theoretical and experimental work is required to substantiate fully the proposed procedure.

  1. From Phonomecanocardiography to Phonocardiography computer aided

    NASA Astrophysics Data System (ADS)

    Granados, J.; Tavera, F.; López, G.; Velázquez, J. M.; Hernández, R. T.; López, G. A.

    2017-01-01

    Due to lack of training doctors to identify many of the disorders in the heart by conventional listening, it is necessary to add an objective and methodological analysis to support this technique. In order to obtain information of the performance of the heart to be able to diagnose heart disease through a simple, cost-effective procedure by means of a data acquisition system, we have obtained Phonocardiograms (PCG), which are images of the sounds emitted by the heart. A program of acoustic, visual and artificial vision recognition was elaborated to interpret them. Based on the results of previous research of cardiologists a code of interpretation of PCG and associated diseases was elaborated. Also a site, within the university campus, of experimental sampling of cardiac data was created. Phonocardiography computer-aided is a viable and low cost procedure which provides additional medical information to make a diagnosis of complex heart diseases. We show some previous results.

  2. Crystal structure optimisation using an auxiliary equation of state

    NASA Astrophysics Data System (ADS)

    Jackson, Adam J.; Skelton, Jonathan M.; Hendon, Christopher H.; Butler, Keith T.; Walsh, Aron

    2015-11-01

    Standard procedures for local crystal-structure optimisation involve numerous energy and force calculations. It is common to calculate an energy-volume curve, fitting an equation of state around the equilibrium cell volume. This is a computationally intensive process, in particular, for low-symmetry crystal structures where each isochoric optimisation involves energy minimisation over many degrees of freedom. Such procedures can be prohibitive for non-local exchange-correlation functionals or other "beyond" density functional theory electronic structure techniques, particularly where analytical gradients are not available. We present a simple approach for efficient optimisation of crystal structures based on a known equation of state. The equilibrium volume can be predicted from one single-point calculation and refined with successive calculations if required. The approach is validated for PbS, PbTe, ZnS, and ZnTe using nine density functionals and applied to the quaternary semiconductor Cu2ZnSnS4 and the magnetic metal-organic framework HKUST-1.

  3. Inside out: meet the operators inside the horizon. On bulk reconstruction behind causal horizons

    NASA Astrophysics Data System (ADS)

    Almheiri, Ahmed; Anous, Tarek; Lewkowycz, Aitor

    2018-01-01

    Based on the work of Heemskerk, Marolf, Polchinski and Sully (HMPS), we study the reconstruction of operators behind causal horizons in time dependent geometries obtained by acting with shockwaves on pure states or thermal states. These geometries admit a natural basis of gauge invariant operators, namely those geodesically dressed to the boundary along geodesics which emanate from the bifurcate horizon at constant Rindler time. We outline a procedure for obtaining operators behind the causal horizon but inside the entanglement wedge by exploiting the equality between bulk and boundary time evolution, as well as the freedom to consider the operators evolved by distinct Hamiltonians. This requires we carefully keep track of how the operators are gravitationally dressed and that we address issues regarding background dependence. We compare this procedure to reconstruction using modular flow, and illustrate some formal points in simple cases such as AdS2 and AdS3.

  4. Solution-mediated cladding doping of commercial polymer optical fibers

    NASA Astrophysics Data System (ADS)

    Stajanca, Pavol; Topolniak, Ievgeniia; Pötschke, Samuel; Krebber, Katerina

    2018-03-01

    Solution doping of commercial polymethyl methacrylate (PMMA) polymer optical fibers (POFs) is presented as a novel approach for preparation of custom cladding-doped POFs (CD-POFs). The presented method is based on a solution-mediated diffusion of dopant molecules into the fiber cladding upon soaking of POFs in a methanol-dopant solution. The method was tested on three different commercial POFs using Rhodamine B as a fluorescent dopant. The dynamics of the diffusion process was studied in order to optimize the doping procedure in terms of selection of the most suitable POF, doping time and conditions. Using the optimized procedure, longer segment of fluorescent CD-POF was prepared and its performance was characterized. Fiber's potential for sensing and illumination applications was demonstrated and discussed. The proposed method represents a simple and cheap way for fabrication of custom, short to medium length CD-POFs with various dopants.

  5. Matched asymptotic expansion of the Hamilton-Jacobi-Bellman equation for aeroassisted plane-change maneuvers

    NASA Technical Reports Server (NTRS)

    Calise, Anthony J.; Melamed, Nahum

    1993-01-01

    In this paper we develop a general procedure for constructing a matched asymptotic expansion of the Hamilton-Jacobi-Bellman equation based on the method of characteristics. The development is for a class of perturbation problems whose solution exhibits two-time-scale behavior. A regular expansion for problems of this type is inappropriate since it is not uniformly valid over a narrow range of the independent variable. Of particular interest here is the manner in which matching and boundary conditions are enforced when the expansion is carried out to first order. Two cases are distinguished - one where the left boundary condition coincides with or lies to the right of the singular region and one where the left boundary condition lies to the left of the singular region. A simple example is used to illustrate the procedure, and its potential application to aeroassisted plane change is described.

  6. An ICT-Based Platform to Monitor Protocols in the Healthcare Environment.

    PubMed

    Rorís, Víctor M Alonso; Gago, Juan M Santos; Sabucedo, Luis Álvarez; Merino, Mateo Ramos; Valero, Javier Sanz

    2016-10-01

    Procedures from the healthcare domain involve highly critical actions as they may pose a risk for patients' life. Therefore, a large effort is devoted to the standardization in clinical praxis and to the control of quality for these protocols in order to minimize hazards. In this line, this work is compelled to provide an ICT-based support to carry out these controls in a simple and effective manner. Using a methodology based on HACCP and taking advantage of Semantic tools, a holistic platform of services for traceability and control of processes has been designed and implemented. The applied paradigm is based on the use of Control Points as singular points to generate traces using observations and measures relevant for the processes considered. Based on those, it is possible to offer services for advanced querying and knowledge inference. The local deployment just requires regular mobile phones or tablets making this solution cost-effective and easily replicable.

  7. Statistical Properties of Maximum Likelihood Estimators of Power Law Spectra Information

    NASA Technical Reports Server (NTRS)

    Howell, L. W.

    2002-01-01

    A simple power law model consisting of a single spectral index, a is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at the knee energy, E(sub k), to a steeper spectral index alpha(sub 2) greater than alpha(sub 1) above E(sub k). The Maximum likelihood (ML) procedure was developed for estimating the single parameter alpha(sub 1) of a simple power law energy spectrum and generalized to estimate the three spectral parameters of the broken power law energy spectrum from simulated detector responses and real cosmic-ray data. The statistical properties of the ML estimator were investigated and shown to have the three desirable properties: (P1) consistency (asymptotically unbiased). (P2) efficiency asymptotically attains the Cramer-Rao minimum variance bound), and (P3) asymptotically normally distributed, under a wide range of potential detector response functions. Attainment of these properties necessarily implies that the ML estimation procedure provides the best unbiased estimator possible. While simulation studies can easily determine if a given estimation procedure provides an unbiased estimate of the spectra information, and whether or not the estimator is approximately normally distributed, attainment of the Cramer-Rao bound (CRB) can only he ascertained by calculating the CRB for an assumed energy spectrum-detector response function combination, which can be quite formidable in practice. However. the effort in calculating the CRB is very worthwhile because it provides the necessary means to compare the efficiency of competing estimation techniques and, furthermore, provides a stopping rule in the search for the best unbiased estimator. Consequently, the CRB for both the simple and broken power law energy spectra are derived herein and the conditions under which they are attained in practice are investigated. The ML technique is then extended to estimate spectra information from an arbitrary number of astrophysics data sets produced by vastly different science instruments. This theory and its successful implementation will facilitate the interpretation of spectral information from multiple astrophysics missions and thereby permit the derivation of superior spectral parameter estimates based on the combination of data sets.

  8. Vision-Based Control of a Handheld Surgical Micromanipulator with Virtual Fixtures

    PubMed Central

    Becker, Brian C.; MacLachlan, Robert A.; Lobes, Louis A.; Hager, Gregory D.; Riviere, Cameron N.

    2012-01-01

    Performing micromanipulation and delicate operations in submillimeter workspaces is difficult because of destabilizing tremor and imprecise targeting. Accurate micromanipulation is especially important for microsurgical procedures, such as vitreoretinal surgery, to maximize successful outcomes and minimize collateral damage. Robotic aid combined with filtering techniques that suppress tremor frequency bands increases performance; however, if knowledge of the operator’s goals is available, virtual fixtures have been shown to further improve performance. In this paper, we derive a virtual fixture framework for active handheld micromanipulators that is based on high-bandwidth position measurements rather than forces applied to a robot handle. For applicability in surgical environments, the fixtures are generated in real-time from microscope video during the procedure. Additionally, we develop motion scaling behavior around virtual fixtures as a simple and direct extension to the proposed framework. We demonstrate that virtual fixtures significantly outperform tremor cancellation algorithms on a set of synthetic tracing tasks (p < 0.05). In more medically relevant experiments of vein tracing and membrane peeling in eye phantoms, virtual fixtures can significantly reduce both positioning error and forces applied to tissue (p < 0.05). PMID:24639624

  9. Practical implementation of the double linear damage rule and damage curve approach for treating cumulative fatigue damage

    NASA Technical Reports Server (NTRS)

    Manson, S. S.; Halford, G. R.

    1981-01-01

    Simple procedures are given for treating cumulative fatigue damage under complex loading history using either the damage curve concept or the double linear damage rule. A single equation is given for use with the damage curve approach; each loading event providing a fraction of damage until failure is presumed to occur when the damage sum becomes unity. For the double linear damage rule, analytical expressions are given for determining the two phases of life. The procedure comprises two steps, each similar to the conventional application of the commonly used linear damage rule. Once the sum of cycle ratios based on Phase I lives reaches unity, Phase I is presumed complete, and further loadings are summed as cycle ratios based on Phase II lives. When the Phase II sum attains unity, failure is presumed to occur. It is noted that no physical properties or material constants other than those normally used in a conventional linear damage rule analysis are required for application of either of the two cumulative damage methods described. Illustrations and comparisons are discussed for both methods.

  10. Use of the earlobe in auricular reconstruction post tumour extirpation.

    PubMed

    Chadha, A; Grob, M; Soldin, M

    2009-04-01

    The exact location and topography of defects resulting from surgical excision of cutaneous malignancies of the auricle demand a customized approach based on an awareness of locally redundant tissue. With advancing age, the earlobe becomes ideal for this reconstructive role and we describe an earlobe flap created along the longitudinal axis of lobular tissue. This reliable, simple, one-step procedure provides adequate tissue cover for defects of the antitragus and adjoining concha. Flap vascularity is satisfactory and although the overall size of the ear is reduced, this is accepted for a rejuvenated shape and minimal morbidity.

  11. Simple Approach to Renormalize the Cabibbo-Kobayashi-Maskawa Matrix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kniehl, Bernd A.; Sirlin, Alberto

    2006-12-01

    We present an on-shell scheme to renormalize the Cabibbo-Kobayashi-Maskawa (CKM) matrix. It is based on a novel procedure to separate the external-leg mixing corrections into gauge-independent self-mass and gauge-dependent wave function renormalization contributions, and to implement the on-shell renormalization of the former with nondiagonal mass counterterm matrices. Diagonalization of the complete mass matrix leads to an explicit CKM counterterm matrix, which automatically satisfies all the following important properties: it is gauge independent, preserves unitarity, and leads to renormalized amplitudes that are nonsingular in the limit in which any two fermions become mass degenerate.

  12. Fifth Metatarsal Osteotomies.

    PubMed

    Weil, Lowell; Consul, Devon

    2015-07-01

    A tailor's bunion or bunionette deformity is a combination of osseous and soft tissue bursitis on the lateral aspect of the fifth metatarsal head. This article discusses 7 corrective measures: medial oblique sliding osteotomy with fixation, medial oblique slide osteotomy-minimal incision procedure without fixation, SERI (simple, effective, rapid, inexpensive) with fixation, chevron with or without fixation, closing, lateral wedge osteotomy at the metatarsal neck or proximal diaphysis, Weil osteotomy, and scarfette. These evidence-based techniques can be used by practitioners for medical management of their patients through evaluation, diagnosis, and prognosis. Complications are also addressed. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. A Simple Picaxe Microcontroller Pulse Source for Juxtacellular Neuronal Labelling.

    PubMed

    Verberne, Anthony J M

    2016-10-19

    Juxtacellular neuronal labelling is a method which allows neurophysiologists to fill physiologically-identified neurons with small positively-charged marker molecules. Labelled neurons are identified by histochemical processing of brain sections along with immunohistochemical identification of neuropeptides, neurotransmitters, neurotransmitter transporters or biosynthetic enzymes. A microcontroller-based pulser circuit and associated BASIC software script is described for incorporation into the design of a commercially-available intracellular electrometer for use in juxtacellular neuronal labelling. Printed circuit board construction has been used for reliability and reproducibility. The current design obviates the need for a separate digital pulse source and simplifies the juxtacellular neuronal labelling procedure.

  14. Transtracheal aspiration in the diagnosis of pulmonary blastomycosis (17 cases: 2000–2005)

    PubMed Central

    McMillan, Chantal J.; Taylor, Susan M.

    2008-01-01

    Blastomyces dermatitidis is a common etiologic agent of fungal pneumonia in dogs. Definitive diagnosis is based on cytologic demonstration of the organism in affected tissues. Fluid obtained through transtracheal aspiration has previously been reported to have a low diagnostic yield for B. dermatitidis organisms. This retrospective study identified B. dermatitidis organisms in 76% of samples when transtracheal aspiration was performed in 17 nonsedated dogs with pulmonary blastomycosis. Transtracheal aspiration is a noninvasive and simple procedure that should be considered as an early diagnostic test whenever blastomycosis is a differential diagnosis in dogs with pulmonary disease. PMID:18320978

  15. [Research progress of three-dimensional digital model for repair and reconstruction of knee joint].

    PubMed

    Tong, Lu; Li, Yanlin; Hu, Meng

    2013-01-01

    To review recent advance in the application and research of three-dimensional digital knee model. The recent original articles about three-dimensional digital knee model were extensively reviewed and analyzed. The digital three-dimensional knee model can simulate the knee complex anatomical structure very well. Based on this, there are some developments of new software and techniques, and good clinical results are achieved. With the development of computer techniques and software, the knee repair and reconstruction procedure has been improved, the operation will be more simple and its accuracy will be further improved.

  16. An analysis of life expectancy of airplane wings in normal cruising flight

    NASA Technical Reports Server (NTRS)

    Putnam, Abbott A

    1945-01-01

    In order to provide a basis for judging the relative importance of wing failure by fatigue and by single intense gusts, an analysis of wing life for normal cruising flight was made based on data on the frequency of atmospheric gusts. The independent variables considered in the analysis included stress-concentration factor, stress-load relation, wing loading, design and cruising speeds, design gust velocity, and airplane size. Several methods for estimating fatigue life from gust frequencies are discussed. The procedure selected for the analysis is believed to be simple and reasonably accurate, though slightly conservative.

  17. Basic principles of Hasse diagram technique in chemistry.

    PubMed

    Brüggemann, Rainer; Voigt, Kristina

    2008-11-01

    Principles of partial order applied to ranking are explained. The Hasse diagram technique (HDT) is the application of partial order theory based on a data matrix. In this paper, HDT is introduced in a stepwise procedure, and some elementary theorems are exemplified. The focus is to show how the multivariate character of a data matrix is realized by HDT and in which cases one should apply other mathematical or statistical methods. Many simple examples illustrate the basic theoretical ideas. Finally, it is shown that HDT is a useful alternative for the evaluation of antifouling agents, which was originally performed by amoeba diagrams.

  18. Escherichia coli promoter sequences predict in vitro RNA polymerase selectivity.

    PubMed

    Mulligan, M E; Hawley, D K; Entriken, R; McClure, W R

    1984-01-11

    We describe a simple algorithm for computing a homology score for Escherichia coli promoters based on DNA sequence alone. The homology score was related to 31 values, measured in vitro, of RNA polymerase selectivity, which we define as the product KBk2, the apparent second order rate constant for open complex formation. We found that promoter strength could be predicted to within a factor of +/-4.1 in KBk2 over a range of 10(4) in the same parameter. The quantitative evaluation was linked to an automated (Apple II) procedure for searching and evaluating possible promoters in DNA sequence files.

  19. A revisitation of TRIX for trophic status assessment in the light of the European Water Framework Directive: application to Italian coastal waters.

    PubMed

    Pettine, Maurizio; Casentini, Barbara; Fazi, Stefano; Giovanardi, Franco; Pagnotta, Romano

    2007-09-01

    The trophic status classification of coastal waters at the European scale requires the availability of harmonised indicators and procedures. The composite trophic status index (TRIX) provides useful metrics for the assessment of the trophic status of coastal waters. It was originally developed for Italian coastal waters and then applied in many European seas (Adriatic, Tyrrhenian, Baltic, Black and Northern seas). The TRIX index does not fulfil the classification procedure suggested by the WFD for two reasons: (a) it is based on an absolute trophic scale without any normalization to type-specific reference conditions; (b) it makes an ex ante aggregation of biological (Chl-a) and physico-chemical (oxygen, nutrients) quality elements, instead of an ex post integration of separate evaluations of biological and subsequent chemical quality elements. A revisitation of the TRIX index in the light of the European Water Framework Directive (WFD, 2000/60/EC) and new TRIX derived tools are presented in this paper. A number of Italian coastal sites were grouped into different types based on a thorough analysis of their hydro-morphological conditions, and type-specific reference sites were selected. Unscaled TRIX values (UNTRIX) for reference and impacted sites have been calculated and two alternative UNTRIX-based classification procedures are discussed. The proposed procedures, to be validated on a broader scale, provide users with simple tools that give an integrated view of nutrient enrichment and its effects on algal biomass (Chl-a) and on oxygen levels. This trophic evaluation along with phytoplankton indicator species and algal blooms contribute to the comprehensive assessment of phytoplankton, one of the biological quality elements in coastal waters.

  20. New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis.

    PubMed

    Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien

    2015-02-17

    Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.

Top