USDA-ARS?s Scientific Manuscript database
Although Campylobacter is an important food-borne human pathogen, there remains a lack of molecular diagnostic assays that are simple to use, cost-effective, and provide rapid results in research, clinical, or regulatory laboratories. Of the numerous Campylobacter assays that do exist, to our knowl...
[Microbiology--laboratory examinations for bacterias].
Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi
2002-11-01
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
Hemorrhagic Fever with Renal Syndrome (Korean Hemorrhagic Fever)
1990-06-29
particles were used for a rapid serologic diagnostic test for HFRS. ’te-re were 430 cases of HFRS in Korea in 1989 and large outbreaks of scrub typhus...almost same as in 1988. A simple and rapid serologic diagnostic test for hantavirus infection was developed by high density particle agglutination...infection and HFRS b) serologic relation cif hantaviruses isolated from the different parts of the world c) development of a simple serologic diagnostic
A rapid and ultrasensitive SERRS assay for histidine and tyrosine based on azo coupling.
Sui, Huimin; Wang, Yue; Yu, Zhi; Cong, Qian; Han, Xiao Xia; Zhao, Bing
2016-10-01
A simple and highly sensitive surface-enhanced resonance Raman scattering (SERRS)-based approach coupled with azo coupling reaction has been put forward for quantitative analysis of histidine and tyrosine. The SERRS-based assay is simple and rapid by mixing the azo reaction products with silver nanoparticles (AgNPs) for measurements within 2min. The limits of detection (LODs) of the method are as low as 4.33×10(-11) and 8.80×10(-11)M for histidine and tyrosine, respectively. Moreover, the SERRS fingerprint information specific to corresponding amino acids guarantees the selective detection for the target histidine and tyrosine. The results from serum indicated the potential application of the proposed approach into biological samples. Compared with the methods ever reported, the main advantages of this methodology are simpleness, rapidity without time-consuming separation or pretreatment steps, high sensitivity, selectivity and the potential for determination of other molecules containing imidazole or phenol groups. Copyright © 2016 Elsevier B.V. All rights reserved.
Stephen, Zachary R; Dayringer, Christopher J; Lim, Josh J; Revia, Richard A; Halbert, Mackenzie V; Jeon, Mike; Bakthavatsalam, Arvind; Ellenbogen, Richard G; Zhang, Miqin
2016-03-01
Surface functionalization of theranostic nanoparticles (NPs) typically relies on lengthy, aqueous postsynthesis labeling chemistries that have limited ability to fine-tune surface properties and can lead to NP heterogeneity. The need for a rapid, simple synthesis approach that can provide great control over the display of functional moieties on NP surfaces has led to increased use of highly selective bioorthoganol chemistries including metal-affinity coordination. Here we report a simple approach for rapid production of a superparamagnetic iron oxide NPs (SPIONs) with tunable functionality and high reproducibility under aqueous conditions. We utilize the high affinity complex formed between catechol and Fe((III)) as a means to dock well-defined catechol modified polymer modules on the surface of SPIONs during sonochemical coprecipitation synthesis. Polymer modules consisted of chitosan and poly(ethylene glycol) (PEG) copolymer (CP) modified with catechol (CCP), and CCP functionalized with cationic polyethylenimine (CCP-PEI) to facilitate binding and delivery of DNA for gene therapy. This rapid synthesis/functionalization approach provided excellent control over the extent of PEI labeling, improved SPION magnetic resonance imaging (MRI) contrast enhancement and produced an efficient transfection agent.
Jin, Hui; Lao, Yong Min; Zhou, Jin; Zhang, Huai Jin; Cai, Zhong Hua
2017-03-10
A simple ultra-high-pressure liquid chromatography (UHPLC) method for rapidly and simultaneously identifying thirteen carotenoids in Haematococcus pluvialis was developed in this study. The method is capable of effectively separating two astaxanthin isomers, two ζ-carotene isomers, and three phytoene isomers on two simple C18 columns within 9 and 12min only by using methanol and acetonitrile, respectively. To our best knowledge, this is the rapidest method for these carotenoid isomers, currently. Using this method, carotenoid profiling in the astaxanthin-accumulating H. pluvialis under environmental stresses was successfully carried out. Results indicated that carotenoid biosynthesis was differentially perturbed by environmental stresses, indicating that this simple and rapid method is suitable to not only bacterial but also algal samples, with potential applications for a wide range of samples from plant to animal. Finally, possible reasons for the elution order of carotenoids were studied. Copyright © 2017 Elsevier B.V. All rights reserved.
SERS-based pesticide detection by using nanofinger sensors
NASA Astrophysics Data System (ADS)
Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong
2015-01-01
Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.
López-Ferrer, Daniel; Hixson, Kim K.; Smallwood, Heather; Squier, Thomas C.; Petritis, Konstantinos; Smith, Richard D.
2009-01-01
A new method that uses immobilized trypsin concomitant with ultrasonic irradiation results in ultra-rapid digestion and thorough 18O labeling for quantitative protein comparisons. The reproducible and highly efficient method provided effective digestions in <1 min with a minimized amount of enzyme required compared to traditional methods. This method was demonstrated for digestion of both simple and complex protein mixtures, including bovine serum albumin, a global proteome extract from the bacteria Shewanella oneidensis, and mouse plasma, as well as 18O labeling of such complex protein mixtures, which validated the application of this method for differential proteomic measurements. This approach is simple, reproducible, cost effective, rapid, and thus well-suited for automation. PMID:19555078
NASA Astrophysics Data System (ADS)
Viboonratanasri, Duangkamon; Pabchanda, Suwat; Prompinit, Panida
2018-05-01
In this study, a simple, rapid and relatively less toxic method for rhodamine 6G dye adsorption on hydrogen-form Y-type zeolite for highly selective nitrite detection was demonstrated. The adsorption behavior was described by Langmuir isotherm and the adsorption process reached the equilibrium promptly within a minute. The developed test papers characterized by fluorescence technique display high sensing performance with wide working range (0.04-20.0 mg L-1) and high selectivity. The test papers show good reproducibility with relative standard deviation (RSD) of 7% for five replicated determinations of 3 mg L-1 of nitrite. The nitrite concentration determined by using the test paper was in the same range as using ion chromatography within a 95% confidence level. The test papers offer advantages in terms of low cost and practical usage enabling them to be a promising candidate for nitrite sensor in environmental samples, food, and fertilizers.
Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei
2016-07-01
In many parts of the world, the possession and cultivation of Cannabis sativa L. are restricted by law. As chemical or morphological analyses cannot identify the plant in some cases, a simple yet accurate DNA-based method for identifying C. sativa is desired. We have developed a loop-mediated isothermal amplification (LAMP) assay for the rapid identification of C. sativa. By optimizing the conditions for the LAMP reaction that targets a highly conserved region of tetrahydrocannabinolic acid (THCA) synthase gene, C. sativa was identified within 50 min at 60-66°C. The detection limit was the same as or higher than that of conventional PCR. The LAMP assay detected all 21 specimens of C. sativa, showing high specificity. Using a simple protocol, the identification of C. sativa could be accomplished within 90 min from sample treatment to detection without use of special equipment. A rapid, sensitive, highly specific, and convenient method for detecting and identifying C. sativa has been developed and is applicable to forensic investigations and industrial quality control.
A simple model of hohlraum power balance and mitigation of SRS
Albright, Brian J.; Montgomery, David S.; Yin, Lin; ...
2016-04-01
A simple energy balance model has been obtained for laser-plasma heating in indirect drive hohlraum plasma that allows rapid temperature scaling and evolution with parameters such as plasma density and composition. Furthermore, this model enables assessment of the effects on plasma temperature of, e.g., adding high-Z dopant to the gas fill or magnetic fields.
Saito, Ryoichi; Koyano, Saho; Dorin, Misato; Higurashi, Yoshimi; Misawa, Yoshiki; Nagano, Noriyuki; Kaneko, Takamasa; Moriya, Kyoji
2015-01-01
We investigated the performance of a phenotypic test, the Carbapenemase Detection Set (MAST-CDS), for the identification of carbapenemase-producing Enterobacteriaceae. Our results indicated that MAST-CDS is rapid, easily performed, simple to interpret, and highly sensitive for the identification of carbapenemase producers, particularly imipenemase producers. Copyright © 2014 Elsevier B.V. All rights reserved.
Durán, Gema M; Contento, Ana M; Ríos, Ángel
2013-11-01
Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L(-1). The lineal range was between 10-5×10(3) ng L(-1). RSD values in the range of 71-102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence. Copyright © 2013 Elsevier B.V. All rights reserved.
Shaikh, Abdul S; Guo, Ruichen
2017-01-01
Phenytoin has very challenging pharmacokinetic properties. To prevent its toxicity and ensure efficacy, continuous therapeutic monitoring is required. It is hard to get a simple, accurate, rapid, easily available, economical and highly sensitive assay in one method for therapeutic monitoring of phenytoin. The present study is directed towards establishing and validating a simpler, rapid, an accurate, highly sensitive, novel and environment friendly liquid chromatography/mass spectrometry (LC/MS) method for offering rapid and reliable TDM results of phenytoin in epileptic patients to physicians and clinicians for making immediate and rational decision. 27 epileptics patients with uncontrolled seizures or suspected of non-compliance or toxicity of phenytoin were selected and advised for TDM of phenytoin by neurologists of Qilu Hospital Jinan, China. The LC/MS assay was used for performing of therapeutic monitoring of phenytoin. The Agilent 1100 LC/MS system was used for TDM. The mixture of Ammonium acetate 5mM: Methanol at (35: 65 v/v) was used for the composition of mobile phase. The Diamonsil C18 (150mm×4.6mm, 5μm) column was used for the extraction of analytes in plasma. The samples were prepared with one step simple protein precipitation method. The technique was validated with the guidelines of International Conference on Harmonisation (ICH). The calibration curve demonstrated decent linearity within (0.2-20 µg/mL) concentration range with linearity equation, y= 0.0667855 x +0.00241785 and correlation coefficient (R2) of 0.99928. The specificity, recovery, linearity, accuracy, precision and stability results were within the accepted limits. The concentration of 0.2 µg/mL was observed as lower limit of quantitation (LLOQ), which is 12.5 times lower than the currently available enzyme-multiplied immunoassay technique (EMIT) for measurement of phenytoin in epilepsy patients. A rapid, simple, economical, precise, highly sensitive and novel LC/MS assay has been established, validated and applied successfully in TDM of 27 epileptics patients. It was alarmingly found that TDM results of all these patients were out of safe range except two patients. However, it needs further evaluation. Besides TDM, the stated method can also be applied in bioequivalence, pharmacokinetics, toxicokinetics and pharmacovigilance studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Nzelu, Chukwunonso O; Cáceres, Abraham G; Guerrero-Quincho, Silvia; Tineo-Villafuerte, Edwin; Rodriquez-Delfin, Luis; Mimori, Tatsuyuki; Uezato, Hiroshi; Katakura, Ken; Gomez, Eduardo A; Guevara, Angel G; Hashiguchi, Yoshihisa; Kato, Hirotomo
2016-01-01
Leishmaniasis remains one of the world's most neglected diseases, and early detection of the infectious agent, especially in developing countries, will require a simple and rapid test. In this study, we established a quick, one-step, single-tube, highly sensitive loop-mediated isothermal amplification (LAMP) assay for rapid detection of Leishmania DNA from tissue materials spotted on an FTA card. An FTA-LAMP with pre-added malachite green was performed at 64°C for 60min using a heating block and/or water bath and DNA amplification was detected immediately after incubation. The LAMP assay had high detection sensitivity down to a level of 0.01 parasites per μl. The field- and clinic-applicability of the colorimetric FTA-LAMP assay was demonstrated with 122 clinical samples collected from patients suspected of having cutaneous leishmaniasis in Peru, from which 71 positives were detected. The LAMP assay in combination with an FTA card described here is rapid and sensitive, as well as simple to perform, and has great potential usefulness for diagnosis and surveillance of leishmaniasis in endemic areas. Copyright © 2015 Elsevier B.V. All rights reserved.
Le, Tao; Zhang, Zhihao; Wu, Juan; Shi, Haixing; Cao, Xudong
2018-01-01
A rapid, simple, and sensitive fluorescent immunochromatographic strip test (ICST) based on quantum dots (QDs) has been developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. To achieve this, QD-labeled antibody conjugates, which consist of CdSe/ZnS QDs and monoclonal antibodies, were prepared by an activated ester method. Under optimal conditions, with the nitrophenyl derivative of AHD as the target, the ICST had a linear range from 0.1 to 100 ng/mL, with a correlation coefficient of 0.9656 and a 50% inhibitory concentration of 4.51 ng/mL. The limit of detection was 0.14 ng/g, which was below the minimum required performance limit of 1 μg/kg for AHD established by the European Commission. The recoveries for AHD ranged from 81.5% to 108.2%, with coefficients of variation below 13%, based on intraday and interday analysis. Furthermore, for AHD in real samples, the ICST showed high reliability and high correlation with liquid chromatography-tandem mass spectrometry (correlation coefficient of 0.9916). To the best of our knowledge, this is the first report of a novel and sensitive method based on a fluorescent ICST to detect AHD below the minimum required performance limit. The ICST demonstrated high reliability, and could be ideally suited for rapid, simple, and on-site screening of AHD contamination in animal tissues. Graphical abstract A rapid, simple, and sensitive fluorescent immunochromatographic strip test that is based on quantum dots was developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. 2-NBA 2-nitrobenzaldehyde, NP nitrophenyl.
Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.
Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot
2007-01-04
The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.
[Principle of LAMP method--a simple and rapid gene amplification method].
Ushikubo, Hiroshi
2004-06-01
So far nucleic acid test (NAT) has been employed in various fields, including infectious disease diagnoses. However, due to its complicated procedures and relatively high cost, it has not been widely utilized in many actual diagnostic applications. We have therefore developed a simple and rapid gene amplification technology, Loop-mediated Isothermal Amplification (LAMP) method, which has shown prominent results of surpassing the performance of the conventional gene amplification methods. LAMP method acquires three main features: (1) all reaction can be carried out under isothermal conditions; (2) the amplification efficiency is extremely high and tremendous amount of amplification products can be obtained; and (3) the reaction is highly specific. Furthermore, developed from the standard LAMP method, a rapid LAMP method, by adding in the loop primers, can reduce the amplification time from the previous 1 hour to less than 30 minutes. Enormous amount of white precipitate of magnesium pyrophosphate is produced as a by-product of the amplification, therefore, direct visual detection is possible without using any reaction indicators and detection equipments. We believe LAMP technology, with the integration of these features, can rightly apply to clinical genetic testing, food and environmental analysis, as well as NAT in different fields.
A Simple Method for High Throughput Chemical Screening in Caenorhabditis Elegans
Lucanic, Mark; Garrett, Theo; Gill, Matthew S.; Lithgow, Gordon J.
2018-01-01
Caenorhabditis elegans is a useful organism for testing chemical effects on physiology. Whole organism small molecule screens offer significant advantages for identifying biologically active chemical structures that can modify complex phenotypes such as lifespan. Described here is a simple protocol for producing hundreds of 96-well culture plates with fairly consistent numbers of C. elegans in each well. Next, we specified how to use these cultures to screen thousands of chemicals for effects on the lifespan of the nematode C. elegans. This protocol makes use of temperature sensitive sterile strains, agar plate conditions, and simple animal handling to facilitate the rapid and high throughput production of synchronized animal cultures for screening. PMID:29630057
One-pot synthesis of monodisperse CoFe2O4@Ag core-shell nanoparticles and their characterization.
Hara, Shuta; Aisu, Jumpei; Kato, Masahiro; Aono, Takashige; Sugawa, Kosuke; Takase, Kouichi; Otsuki, Joe; Shimizu, Shigeru; Ikake, Hiroki
2018-06-08
In recent years, monodispersed magnetic nanoparticles with a core/shell structure are expected for their wide applications including magnetic fluid, recoverable catalysts, and biological analysis. However, their synthesis method needs numerous processes such as solvent substitution, exchange of protective agents, and centrifugation. A simple and rapid method for the synthesis of monodispersed core-shell nanoparticles makes it possible to accelerate their further applications. This paper describes a simple and rapid one-pot synthesis of core (CoFe 2 O 4 )-shell (Ag) nanoparticles with high monodispersity. The synthesized nanoparticles showed plasmonic light absorption owing to the Ag shell. Moreover, the magnetic property of the nanoparticles had a soft magnetic behavior at room temperature and a hard magnetic behavior at 5 K. In addition, the nanoparticles showed high monodispersity with a low polydispersity index (PDI) value of 0.083 in hexane.
One-pot synthesis of monodisperse CoFe2O4@Ag core-shell nanoparticles and their characterization
NASA Astrophysics Data System (ADS)
Hara, Shuta; Aisu, Jumpei; Kato, Masahiro; Aono, Takashige; Sugawa, Kosuke; Takase, Kouichi; Otsuki, Joe; Shimizu, Shigeru; Ikake, Hiroki
2018-06-01
In recent years, monodispersed magnetic nanoparticles with a core/shell structure are expected for their wide applications including magnetic fluid, recoverable catalysts, and biological analysis. However, their synthesis method needs numerous processes such as solvent substitution, exchange of protective agents, and centrifugation. A simple and rapid method for the synthesis of monodispersed core-shell nanoparticles makes it possible to accelerate their further applications. This paper describes a simple and rapid one-pot synthesis of core (CoFe2O4)-shell (Ag) nanoparticles with high monodispersity. The synthesized nanoparticles showed plasmonic light absorption owing to the Ag shell. Moreover, the magnetic property of the nanoparticles had a soft magnetic behavior at room temperature and a hard magnetic behavior at 5 K. In addition, the nanoparticles showed high monodispersity with a low polydispersity index (PDI) value of 0.083 in hexane.
NASA Astrophysics Data System (ADS)
So, Hongyun; Senesky, Debbie G.
2016-11-01
Rapid, cost-effective, and simple fabrication/packaging of microscale gallium nitride (GaN) ultraviolet (UV) sensors are demonstrated using zinc oxide nanorod arrays (ZnO NRAs) as an antireflective layer and direct bonding of aluminum wires to the GaN surface. The presence of the ZnO NRAs on the GaN surface significantly reduced the reflectance to less than 1% in the UV and 4% in the visible light region. As a result, the devices fabricated with ZnO NRAs and mechanically stable aluminum bonding wires (pull strength of 3-5 gf) showed higher sensitivity (136.3% at room temperature and 148.2% increase at 250 °C) when compared with devices with bare (uncoated) GaN surfaces. In addition, the devices demonstrated reliable operation at high temperatures up to 300 °C, supporting the feasibility of simple and cost-effective UV sensors operating with higher sensitivity in high-temperature conditions, such as in combustion, downhole, and space exploration applications.
Just, Jeremy; Deans, Bianca J; Olivier, Wesley J; Paull, Brett; Bissember, Alex C; Smith, Jason A
2015-05-15
A new, practical, rapid, and high-yielding process for the pressurized hot water extraction (PHWE) of multigram quantities of shikimic acid from star anise (Illicium verum) using an unmodified household espresso machine has been developed. This operationally simple and inexpensive method enables the efficient and straightforward isolation of shikimic acid and the facile preparation of a range of its synthetic derivatives.
[Rapid detection of caffeine in blood by freeze-out extraction].
Bekhterev, V N; Gavrilova, S N; Kozina, E P; Maslakov, I V
2010-01-01
A new method for the detection of caffeine in blood has been proposed based on the combination of extraction and freezing-out to eliminate the influence of sample matrix. Metrological characteristics of the method are presented. Selectivity of detection is achieved by optimal conditions of analysis by high performance liquid chromatography. The method is technically simple and cost-efficient, it ensures rapid performance of the studies.
Wang, Limin; Lu, Donglai; Wang, Jun; Du, Dan; Zou, Zhexiang; Wang, Hua; Smith, Jordan N; Timchalk, Charles; Liu, Fengquan; Lin, Yuehe
2011-02-15
We present a novel portable immunochromatographic electrochemical biosensor (IEB) for simple, rapid, and sensitive biomonitoring of trichloropyridinol (TCP), a metabolite biomarker of exposure to organophosphorus insecticides. Our new approach takes the advantage of immunochromatographic test strip for a rapid competitive immunoreaction and a disposable screen-printed carbon electrode for a rapid and sensitive electrochemical analysis of captured HRP labeling. Several key experimental parameters (e.g. immunoreaction time, the amount of HRP labeled TCP, concentration of the substrate for electrochemical measurements, and the blocking agents for the nitrocellulose membrane) were optimized to achieve a high sensitivity, selectivity and stability. Under optimal conditions, the IEB has demonstrated a wide linear range (0.1-100 ng/ml) with a detection limit as low as 0.1 ng/ml TCP. Furthermore, the IEB has been successfully applied for biomonitoring of TCP in the rat plasma samples with in vivo exposure to organophosphorus insecticides like Chlorpyrifos-oxon (CPF-oxon). The IEB thus opens up new pathways for designing a simple, rapid, clinically accurate, and quantitative tool for TCP detection, as well as holds a great promise for in-field screening of metabolite biomarkers, e.g., TCP, for humans exposed to organophosphorus insecticides. Copyright © 2010 Elsevier B.V. All rights reserved.
Simple measurement of lenticular lens quality for autostereoscopic displays
NASA Astrophysics Data System (ADS)
Gray, Stuart; Boudreau, Robert A.
2013-03-01
Lenticular lens based autostereoscopic 3D displays are finding many applications in digital signage and consumer electronics devices. A high quality 3D viewing experience requires the lenticular lens be properly aligned with the pixels on the display device so that each eye views the correct image. This work presents a simple and novel method for rapidly assessing the quality of a lenticular lens to be used in autostereoscopic displays. Errors in lenticular alignment across the entire display are easily observed with a simple test pattern where adjacent views are programmed to display different colors.
Vásquez, Gersson; Rey, Alba; Rivera, Camilo; Iregui, Carlos; Orozco, Jahir
2017-01-15
Pathogenic bacteria are responsible for several diseases in humans and in a variety of hosts. Detection of pathogenic bacteria is imperative to avoid and/or fight their potential harmful effects. This work reports on the first amperometric biosensor for the rapid detection of Streptococcus agalactiae (S. agalactiae). The biosensor relies on a single biotinylated antibody that immobilizes the bacteria on a screen-printed carbon electrode while is further linked to a streptavidin-conjugated HRP reporter. The biotinylated antibody provides selectivity to the biosensor whereas serves as an anchoring point to the reporter for further amplification of the electrochemical signal. The resultant immunosensor is simple, responds rapidly, and allows for the selective and highly sensitive quantification of S. agalactiae cells in a concentration range of 10 1 -10 7 CFUml -1 , with a detection limit of 10CFUml -1 . The approach not only enables a rapid detection and quantification of S. agalactiae in environmental samples but also opens up new opportunities for the simple fabrication of electrochemical immunosensors for different target pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.
Leng, Pei-Qiang; Zhao, Feng-Lan; Yin, Bin-Cheng; Ye, Bang-Ce
2015-05-21
We developed a novel colorimetric method for rapid detection of biogenic amines based on arylalkylamine N-acetyltransferase (aaNAT). The proposed method offers distinct advantages including simple handling, high speed, low cost, good sensitivity and selectivity.
Oakley, Brian B; Line, J Eric; Berrang, Mark E; Johnson, Jessica M; Buhr, R Jeff; Cox, Nelson A; Hiett, Kelli L; Seal, Bruce S
2012-02-01
Although Campylobacter is an important food-borne human pathogen, there remains a lack of molecular diagnostic assays that are simple to use, cost-effective, and provide rapid results in research, clinical, or regulatory laboratories. Of the numerous Campylobacter assays that do exist, to our knowledge none has been empirically tested for specificity using high-throughput sequencing. Here we demonstrate the power of next-generation sequencing to determine the specificity of a widely cited Campylobacter-specific polymerase chain reaction (PCR) assay and describe a rapid method for direct cell suspension PCR to quickly and easily screen samples for Campylobacter. We present a specific protocol which eliminates the need for time-consuming and expensive genomic DNA extractions and, using a high-processivity polymerase, demonstrate conclusive screening of samples in <1 h. Pyrosequencing results show the assay to be extremely (>99%) sensitive, and spike-back experiments demonstrated a detection threshold of <10(2) CFU mL(-1). Additionally, we present 2 newly designed broad-range bacterial primer sets targeting the 23S rRNA gene that have wide applicability as internal amplification controls. Empirical testing of putative taxon-specific assays using high-throughput sequencing is an important validation step that is now financially feasible for research, regulatory, or clinical applications. Published by Elsevier Inc.
Chen, Ming-Jen; Liu, Ya-Ting; Lin, Chiao-Wen; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon
2013-03-12
This paper describes the development of a novel, simple and efficient in-tube based ultrasound-assisted salt-induced liquid-liquid microextraction (IT-USA-SI-LLME) technique for the rapid determination of triclosan (TCS) in personal care products by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. IT-USA-SI-LLME method is based on the rapid phase separation of water-miscible organic solvent from the aqueous phase in the presence of high concentration of salt (salting-out phenomena) under ultrasonication. In the present work, an indigenously fabricated home-made glass extraction device (8-mL glass tube inbuilt with a self-scaled capillary tip) was utilized as the phase separation device for USA-SI-LLME. After the extraction, the upper extractant layer was narrowed into the self-scaled capillary tip by pushing the plunger plug; thus, the collection and measurement of the upper organic solvent layer was simple and convenient. The effects of various parameters on the extraction efficiency were thoroughly evaluated and optimized. Under optimal conditions, detection was linear in the concentration range of 0.4-100ngmL(-1) with correlation coefficient of 0.9968. The limit of detection was 0.09ngmL(-1) and the relative standard deviations ranged between 0.8 and 5.3% (n=5). The applicability of the developed method was demonstrated for the analysis of TCS in different commercial personal care products and the relative recoveries ranged from 90.4 to 98.5%. The present method was proven to be a simple, sensitive, less organic solvent consuming, inexpensive and rapid procedure for analysis of TCS in a variety of commercially available personal care products or cosmetic preparations. Copyright © 2013 Elsevier B.V. All rights reserved.
Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro
2013-06-01
With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.
Zhao, Lingxiao; Pan, Ting; Guo, Dongwei; Wei, Cunxu
2018-01-01
Storage starch in starchy seed influences the seed weight and texture, and determines its applications in food and nonfood industries. Starch granules from different plant sources have significantly different shapes and sizes, and even more the difference exists in the different regions of the same tissue. Therefore, it is very important to in situ investigate the morphology and distribution of starch in the whole seed. However, a simple and rapid method is deficient to prepare the whole section of starchy seed for investigating the morphology and distribution of starch in the whole seeds for a large number of samples. A simple and rapid method was established to prepare the whole section of starchy seed, especially for floury seed, in this study. The whole seeds of translucent and chalky rice, vitreous and floury maize, and normal barley and wheat were sectioned successfully using the newly established method. The iodine-stained section clearly exhibited the shapes and size of starch granules in different regions of seed. The starch granules with different morphologies and iodine-staining colors existed regionally in the seeds of high-amylose rice and maize. The sections of lotus and kidney bean seeds also showed the feasibility of this method for starchy non-cereal seeds. The simple and rapid method was proven effective for preparing the whole sections of starchy seeds. The whole section of seed could be used to investigate the morphology and distribution of starch granules in different regions of the whole seed. The method was especially suitable for large sample numbers to investigate the starch morphology in short time.
Wijemanne, Nimanthi; Soysa, Preethi; Wijesundara, Sulochana; Perera, Hemamali
2018-01-01
Uric acid and hypoxanthine are produced in the catabolism of purine. Abnormal urinary levels of these products are associated with many diseases and therefore it is necessary to have a simple and rapid method to detect them. Hence, we report a simple reverse phase high performance liquid chromatography (HPLC/UV) technique, developed and validated for simultaneous analysis of uric acid, hypoxanthine, and creatinine in human urine. Urine was diluted appropriately and eluted with C-18 column 100 mm × 4.6 mm with a C-18 precolumn 25 mm × 4.6 mm in series. Potassium phosphate buffer (20 mM, pH 7.25) at a flow rate of 0.40 mL/min was employed as the solvent and peaks were detected at 235 nm. Tyrosine was used as the internal standard. The experimental conditions offered a good separation of analytes without interference of endogenous substances. The calibration curves were linear for all test compounds with a regression coefficient, r 2 > 0.99. Uric acid, creatinine, tyrosine, and hypoxanthine were eluted at 5.2, 6.1, 7.2, and 8.3 min, respectively. Intraday and interday variability were less than 4.6% for all the analytes investigated and the recovery ranged from 98 to 102%. The proposed HPLC procedure is a simple, rapid, and low cost method with high accuracy with minimum use of organic solvents. This method was successfully applied for the determination of creatinine, hypoxanthine, and uric acid in human urine.
Gibbs, B F; Alli, I; Mulligan, C N
1996-02-23
A method for the determination of aspartame (N-L-alpha-aspartyl-L-phenylalanine methyl ester) and its metabolites, applicable on a routine quality assurance basis, is described. Liquid samples (diet Coke, 7-Up, Pepsi, etc.) were injected directly onto a mini-cartridge reversed-phase column on a high-performance liquid chromatographic system, whereas solid samples (Equal, hot chocolate powder, pudding, etc.) were extracted with water. Optimising chromatographic conditions resulted in resolved components of interest within 12 min. The by-products were confirmed by mass spectrometry. Although the method was developed on a two-pump HPLC system fitted with a diode-array detector, it is straightforward and can be transformed to the simplest HPLC configuration. Using a single-piston pump (with damper), a fixed-wavelength detector and a recorder/integrator, the degradation of products can be monitored as they decompose. The results obtained were in harmony with previously reported tedious methods. The method is simple, rapid, quantitative and does not involve complex, hazardous or toxic chemistry.
Screening of Compounds Toxicity against Human Monocytic cell line-THP-1 by Flow Cytometry
Pick, Neora; Cameron, Scott; Arad, Dorit
2004-01-01
The worldwide rapid increase in bacterial resistance to numerous antibiotics requires on-going development of new drugs to enter the market. As the development of new antibiotics is lengthy and costly, early monitoring of compound's toxicity is essential in the development of novel agents. Our interest is in a rapid, simple, high throughput screening method to assess cytotoxicity induced by potential agents. Some intracellular pathogens, such as Mycobacterium tuberculosis primary site of infection is human alveolar macrophages. Thus, evaluation of candidate drugs for macrophage toxicity is crucial. Protocols for high throughput drug toxicity screening of macrophages using flow cytometry are lacking in the literature. For this application we modified a preexisting technique, propidium iodide (PI) exclusion staining and utilized it for rapid toxicity tests. Samples were prepared in 96 well plates and analyzed by flow cytometry, which allowed for rapid, inexpensive and precise assessment of compound's toxicity associated with cell death. PMID:15472722
NASA Astrophysics Data System (ADS)
Wu, Shichao; Zhou, Xi; Yang, Xiangrui; Hou, Zhenqing; Shi, Yanfeng; Zhong, Lubin; Jiang, Qian; Zhang, Qiqing
2014-09-01
We report a simple and rapid biological approach to synthesize water-soluble and highly roughened "meatball"-like Au nanoparticles using green tea extract under microwave irradiation. The synthesized Au meatball-like nanoparticles possess excellent monodispersity and uniform size (250 nm in diameter). Raman measurements show that these tea-generated meatball-like gold nanostructures with high active surface areas exhibit a high enhancement of surface-enhanced Raman scattering. In addition, the Au meatball-like nanoparticles demonstrate good biocompatibility and remarkable in vitro stability at the biological temperature. Meanwhile, the factors that influence the Au meatball-like nanoparticles morphology are investigated, and the mechanisms behind the nonspherical shape evolution are discussed.
CAO, Lili; CHENG, Ronghua; YAO, Lin; YUAN, Shuxian; YAO, Xinhua
2013-01-01
ABSTRACT The Loop-mediated isothermal amplification (LAMP) method amplifies DNA with high simply, specificity, sensitivity and rapidity. In this study, A LAMP assay with 6 primers targeting a highly conserved region of the GRA1 gene was developed to diagnose Toxoplasma gondii. The reaction time of the LAMP assay was shortened to 30 min after optimizing the reaction system. The LAMP assay was found to be highly specific and stable. The detection limit of the LAMP assay was 10 copies, the same as that of the conventional PCR. We used the LAMP assay to develop a real-time fluorogenic protocol to quantitate T. gondii DNA and generated a log-linear regression plot by plotting the time-to-threshold values against genomic equivalent copies. Furthermore, the LAMP assay was applied to detect T. gondii DNA in 423 blood samples and 380 lymph node samples from 10 pig farms, and positive results were obtained for 7.8% and 8.2% of samples, respectively. The results showed that the LAMP method is slightly more sensitive than conventional PCR (6.1% and 7.6%). Positive samples obtained from 6 pig farms. The LAMP assay established in this study resulted in simple, specific, sensitive and rapid detection of T. gondii DNA and is expected to play an important role in clinical detection of T. gondii. PMID:23965849
Simple new test for rapid differentiation of Prototheca wickerhamii from Prototheca zopfii.
Casal, M J; Gutierrez, J
1983-01-01
A simple new test to differentiate Prototheca wickerhamii from Prototheca zopfii by determining susceptibility to clotrimazole is described. A 50-micrograms clotrimazole disk provides a rapid and reliable means of distinguishing P. wickerhamii from P. zopfii. PMID:6630477
Mitani, Kurie; Narimatsu, Shizuo; Izushi, Fumio; Kataoka, Hiroyuki
2003-07-14
A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/ml in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops in plastic containers. On the other hand, BPA and alkylphenols were not detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening and determination of endocrine disruptor contamination in liquid medicines and intravenous injection solutions.
Liu, Yan; Yang, Shanli; Niu, Weifen
2013-08-01
Simple, rapid, green and one-step electrodeposition strategy was first proposed to synthesis of graphene/carbon nanotubes/chitosan (GR/CNTs/CS) hybrid. The one-step electrodeposition approach for the construction of GR-based hybrid is green environmentally, which would not involve the chemical reduction of graphene oxide (GO) and therefore result in no further contamination. The whole procedure is simple and needs only several minutes. Combining the advantages of GR (large surface area, high conductivity and good adsorption ability), CNTs (high surface area, high enrichment capability and good adsorption ability) and CS (good adsorption and excellent film-forming ability), the obtained GR/CNTs/CS composite could be highly efficient to capture organophosphate pesticides (OPs) and used as solid phase extraction (SPE). The GR/CNTs/CS sensor is used for enzymeless detection of OPs, using methyl parathion (MP) as a model analyte. Significant redox response of MP on GR/CNTs/CS sensor is proved. The linear range is wide from 2.0ngmL(-1) to 500ngmL(-1), with a detection limit of 0.5ngmL(-1). Detection limit of the proposed sensor is much lower than those enzyme-based sensors and many other enzymeless sensors. Moreover, the proposed sensor exhibits high reproducibility, long-time storage stability and satisfactory anti-interference ability. This work provides a green and one-step route for the preparation of GR-based hybrid, and also offers a new promising protocol for OPs analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Detection of fragments from internal insects in wheat samples using a laboratory entoleter
USDA-ARS?s Scientific Manuscript database
A simple, rapid method was developed for estimating the number of insect fragments in flour caused by hidden, internal-feeding insects in whole grains during storage. The method uses a small mechanical rotary device (entoleter), which accelerates whole wheat kernels to high speeds and projects them...
Engineering Novel Lab Devices Using 3D Printing and Microcontrollers.
Courtemanche, Jean; King, Samson; Bouck, David
2018-03-01
The application of 3D printing and microcontrollers allows users to rapidly engineer novel hardware solutions useful in a laboratory environment. 3D printing is transformative as it enables the rapid fabrication of adapters, housings, jigs, and small structural elements. Microcontrollers allow for the creation of simple, inexpensive machines that receive input from one or more sensors to trigger a mechanical or electrical output. Bringing these technologies together, we have developed custom solutions that improve capabilities and reduce costs, errors, and human intervention. In this article, we describe three devices: JetLid, TipWaster, and Remote Monitoring Device (REMIND). JetLid employs a microcontroller and presence sensor to trigger a high-speed fan that reliably de-lids microtiter plates on a high-throughput screening system. TipWaster uses a presence sensor to activate an active tip waste chute when tips are ejected from a pipetting head. REMIND is a wireless, networked lab monitoring device. In its current implementation, it monitors the liquid level of waste collection vessels or bulk liquid reagent containers. The modularity of this device makes adaptation to other sensors (temperature, humidity, light/darkness, movement, etc.) relatively simple. These three devices illustrate how 3D printing and microcontrollers have enabled the process of rapidly turning ideas into useful devices.
Sun, Hua; Wang, Hong-Tao; Kwon, Woo-Saeng; Kim, Yeon-Ju; In, Jun-Gyo; Yang, Deok-Chun
2011-11-01
Yunpoong is an important Korean ginseng (Panax ginseng C. A. Meyer) cultivar, but no molecular marker has been available to identify Yunpoong from other cultivars. In this study, we developed a single nucleotide polymorphism (SNP) marker for Yunpoong based on analysis of expressed sequence tags (ESTs) in an exon region of the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) gene. This SNP marker had high specificity to authenticate Yunpoong in twelve different main ginseng cultivars. For application of the molecular marker, a rapid identification method was established based on the NaOH-Tris method and real-time polymerase chain reaction (PCR) in order to ensure more efficiency in the cultivar selection. The biggest feature of the NaOH-Tris method was that it made the extraction of DNA very simple and rapid in young leaf tissues. We only spent 1 min to extract DNA and directly used it to do PCR. In this report, the conventional DNA extraction method was used to develop molecular marker process, and the NaOH-Tris method was applied in screening large numbers of cultivars. Moreover, the greatest advantage of the real-time PCR compared with traditional PCR, is time saving and high efficiency. Thus, this strategy provides a rapid and reliable method for the specific identification of Yunpoong in a large number of samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Kawatsu, Kentaro; Kanki, Masashi; Harada, Tetsuya; Kumeda, Yuko
2014-11-01
Using a streptavidin-coated well plate, a biotin-labelled anti-gonyautoxin 2/3 monoclonal antibody GT-13A, and a decarbamoyl saxitoxin-peroxidase conjugate, a direct competitive enzyme-linked immunosorbent assay (PSP-ELISA) was developed for monitoring paralytic shellfish poisoning (PSP) toxins in shellfish. This assay is simple to perform and can be completed in approximately 20 min. The PSP-ELISA was compared to the mouse bioassay (MBA) for the detection of PSP toxins in shellfish samples (n=83) collected from the coast of Osaka Prefecture, Japan. When positive and negative results were indicated based on the regulatory limit for PSP toxins (4 mouse unit(MU)/g of shellfish meat), the PSP-ELISA results showed a sensitivity of 100% (25 of 25) and a specificity of 89.7% (52 of 58 samples) compared to the MBA results. These results suggest that the PSP-ELISA could be used as a rapid and simple screening method prior to the MBA. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rapid 2,2'-bicinchoninic-based xylanase assay compatible with high throughput screening
William R. Kenealy; Thomas W. Jeffries
2003-01-01
High-throughput screening requires simple assays that give reliable quantitative results. A microplate assay was developed for reducing sugar analysis that uses a 2,2'-bicinchoninic-based protein reagent. Endo-1,4-â-D-xylanase activity against oat spelt xylan was detected at activities of 0.002 to 0.011 IU ml−1. The assay is linear for sugar...
Validation of the AVM Blast Computational Modeling and Simulation Tool Set
2015-08-04
by-construction" methodology is powerful and would not be possible without high -level design languages to support validation and verification. [1,4...to enable the making of informed design decisions. Enable rapid exploration of the design trade-space for high -fidelity requirements tradeoffs...live-fire tests, the jump height of the target structure is recorded by using either high speed cameras or a string pot. A simple projectile motion
Setaria viridis floral-dip: A simple and rapid Agrobacterium-medicated transformation method
USDA-ARS?s Scientific Manuscript database
Setaria viridis was recently described as a new monocotyledonous model species for C4 photosynthesis research and genetic transformation. It has biological attributes (rapid life cycle, small genome, diploid, short stature and simple growth requirements) that make it suitable for use as a model plan...
A RAPID AND SIMPLE PHOSPHOLIPASE A ASSAY,
A simple and rapid method for the assay of phospholipase A was developed. As a substrate fresh egg yolk is used which is hydrolyzed by snake venom...phospholipase A at a 10-20 x faster rate than pure lecithin . The released fatty acids, after extraction with appropriate solvents are titrated
Zhang, Chenchu; Hu, Yanlei; Du, Wenqiang; Wu, Peichao; Rao, Shenglong; Cai, Ze; Lao, Zhaoxin; Xu, Bing; Ni, Jincheng; Li, Jiawen; Zhao, Gang; Wu, Dong; Chu, Jiaru; Sugioka, Koji
2016-09-13
Rapid integration of high-quality functional devices in microchannels is in highly demand for miniature lab-on-a-chip applications. This paper demonstrates the embellishment of existing microfluidic devices with integrated micropatterns via femtosecond laser MRAF-based holographic patterning (MHP) microfabrication, which proves two-photon polymerization (TPP) based on spatial light modulator (SLM) to be a rapid and powerful technology for chip functionalization. Optimized mixed region amplitude freedom (MRAF) algorithm has been used to generate high-quality shaped focus field. Base on the optimized parameters, a single-exposure approach is developed to fabricate 200 × 200 μm microstructure arrays in less than 240 ms. Moreover, microtraps, QR code and letters are integrated into a microdevice by the advanced method for particles capture and device identification. These results indicate that such a holographic laser embellishment of microfluidic devices is simple, flexible and easy to access, which has great potential in lab-on-a-chip applications of biological culture, chemical analyses and optofluidic devices.
NASA Astrophysics Data System (ADS)
Zhang, Chenchu; Hu, Yanlei; Du, Wenqiang; Wu, Peichao; Rao, Shenglong; Cai, Ze; Lao, Zhaoxin; Xu, Bing; Ni, Jincheng; Li, Jiawen; Zhao, Gang; Wu, Dong; Chu, Jiaru; Sugioka, Koji
2016-09-01
Rapid integration of high-quality functional devices in microchannels is in highly demand for miniature lab-on-a-chip applications. This paper demonstrates the embellishment of existing microfluidic devices with integrated micropatterns via femtosecond laser MRAF-based holographic patterning (MHP) microfabrication, which proves two-photon polymerization (TPP) based on spatial light modulator (SLM) to be a rapid and powerful technology for chip functionalization. Optimized mixed region amplitude freedom (MRAF) algorithm has been used to generate high-quality shaped focus field. Base on the optimized parameters, a single-exposure approach is developed to fabricate 200 × 200 μm microstructure arrays in less than 240 ms. Moreover, microtraps, QR code and letters are integrated into a microdevice by the advanced method for particles capture and device identification. These results indicate that such a holographic laser embellishment of microfluidic devices is simple, flexible and easy to access, which has great potential in lab-on-a-chip applications of biological culture, chemical analyses and optofluidic devices.
Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini
2016-11-15
For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bojić, Mirza; Simon Haas, Vicente; Maleš, Željan
2013-01-01
Raw material, different formulations of foods, and dietary supplements of mate demands control of the content of bioactive substances for which high performance thin layer chromatography (TLC), described here, presents simple and rapid approach for detections as well as quantification. Using TLC densitometry, the following bioactive compounds were identified and quantified: chlorogenic acid (2.1 mg/g), caffeic acid (1.5 mg/g), rutin (5.2 mg/g), quercetin (2.2 mg/g), and kaempferol (4.5 mg/g). The results obtained with TLC densitometry for caffeine (5.4 mg/g) and theobromine (2.7 mg/g) show no statistical difference to the content of total xanthines (7.6 mg/g) obtained by UV-Vis spectrophotometry. Thus, TLC remains a technique of choice for simple and rapid analysis of great number of samples as well as a primary screening technique in plant analysis. PMID:23841023
ERIC Educational Resources Information Center
Maurye, Praveen; Basu, Arpita; Biswas, Jayanta Kumar; Bandyopadhyay, Tapas Kumar; Naskar, Malay
2018-01-01
Polyacrylamide gel electrophoresis (PAGE) is the most classical technique favored worldwide for resolution of macromolecules in many biochemistry laboratories due to its incessant advanced developments and wide modifications. These ever-growing advancements in the basic laboratory equipments lead to emergence of many expensive, complex, and tricky…
USDA-ARS?s Scientific Manuscript database
The aim of this study was to develop a simple and rapid technique for detecting human norovirus (NoV). The loop-mediated isothermal amplification (LAMP) technique was evaluated and found to be sensitive, highly specific, and useful for routine oyster testing. Reverse transcription-LAMP (RT-LAMP) pri...
High-efficiency water collection on biomimetic material with superwettable patterns.
Zhu, Hai; Yang, Fuchao; Li, Jing; Guo, Zhiguang
2016-10-13
A superhydrophilic surface with two superhydrophobic circular patterns was fabricated via a simple and rapid route, showing outstanding fog harvesting properties with a water collection rate (WCR) of 1316.9 mg h -1 cm -2 . Water collection can be repeated on the sample 10 times without obvious change in the WCR.
Wu, Wenjie; Zhang, Yuan; Wu, Hanqiu; Zhou, Weie; Cheng, Yan; Li, Hongna; Zhang, Chuanbin; Li, Lulu; Huang, Ying; Zhang, Feng
2017-07-01
Isoflavones are natural substances that exhibit hormone-like pharmacological activities. The separation of isoflavones remains an analytical challenge because of their similar structures. We show that ultra-high performance supercritical fluid chromatography can be an appropriate tool to achieve the fast separation of 12 common dietary isoflavones. Among the five tested columns the Torus DEA column was found to be the most effective column for the separation of these isoflavones. The impact of individual parameters on the retention time and separation factor was evaluated. These parameters were optimized to develop a simple, rapid, and green method for the separation of the 12 target analytes. It only took 12.91 min using gradient elution with methanol as an organic modifier and formic acid as an additive. These isoflavones were determined with limit of quantitation ranging from 0.10 to 0.50 μg/mL, which was sufficient for reliable determination of various matrixes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Peng, Lian-Xin; Wang, Jing-Bo; Hu, Li-Xue; Zhao, Jiang-Lin; Xiang, Da-Bing; Zou, Liang; Zhao, Gang
2013-01-30
A simple and rapid method for determining emodin, an active factor presented in tartary buckwheat (Fagopyrum tataricum), by high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) has been developed. Emodin was separated from an extract of buckwheat on a Kromasil-ODS C(18) (250 mm × 4.6 mm × 5 μm) column. The separation is achieved within 15 min on the ODS column. Emodin can be quantified using an external standard method detecting at 436 nm. Good linearity is obtained with a correlation coefficient exceeding 0.9992. The limit of detection and the limit of quantification are 5.7 and 19 μg/L, respectively. This method shows good reproducibility for the quantification of the emodin with a relative standard deviation value of 4.3%. Under optimized extraction conditions, the recovery of emodin was calculated as >90%. The validated method is successfully applied to quantify the emodin in tartary buckwheat and its products.
Tang, G Y; Wu, H J; Wu, L; Li, Z J; Yao, Y G
2001-05-01
The catechins, particularly in green tea, have been found to possess anti-mutagenic and anti-tumorigenic properties. As each catechin possesses distinct properties, a simple and rapid method that could be used for analysis of individual catechins in a complex mixture would be necessary. A relatively simple and rapid method for simultaneous separation of five catechins and caffeine in tea polyphenol by isocratic elution high performance liquid chromatography has been developed. The analysis could be finished within 30 min. They were measured using Resolve C18 column (at 43 degrees C) and UV detector (at 280 nm), water-85% phosphoric acid aqueous solution-acetonitrile-dimethyl formamide(DMF) (859:1:120:20, V/V) as mobile phase. There was a good linear relationship between the content of component and its peak area for catechins and caffeine, with the correlation coefficients of 0.9992-0.9999. The average recoveries (n = 5) were 83.33%-104.42%, and the relative standard deviations (n = 6) were 0.74%-1.43%. The effect of concentration of DMF in mobile phase was studied.
Rapid Characterization of Magnetic Moment of Cells for Magnetic Separation
Ooi, Chinchun; Earhart, Christopher M.; Wilson, Robert J.; Wang, Shan X.
2014-01-01
NCI-H1650 lung cancer cell lines labeled with magnetic nanoparticles via the Epithelial Cell Adhesion Molecule (EpCAM) antigen were previously shown to be captured at high efficiencies by a microfabricated magnetic sifter. If fine control and optimization of the magnetic separation process is to be achieved, it is vital to be able to characterize the labeled cells’ magnetic moment rapidly. We have thus adapted a rapid prototyping method to obtain the saturation magnetic moment of these cells. This method utilizes a cross-correlation algorithm to analyze the cells’ motion in a simple fluidic channel to obtain their magnetophoretic velocity, and is effective even when the magnetic moments of cells are small. This rapid characterization is proven useful in optimizing our microfabricated magnetic sifter procedures for magnetic cell capture. PMID:24771946
Morinha, Francisco; Travassos, Paulo; Seixas, Fernanda; Santos, Nuno; Sargo, Roberto; Sousa, Luís; Magalhães, Paula; Cabral, João A; Bastos, Estela
2013-05-01
High-resolution melting (HRM) analysis is a very attractive and flexible advanced post-PCR method with high sensitivity/specificity for simple, fast and cost-effective genotyping based on the detection of specific melting profiles of PCR products. Next generation real-time PCR systems, along with improved saturating DNA-binding dyes, enable the direct acquisition of HRM data after quantitative PCR. Melting behaviour is particularly influenced by the length, nucleotide sequence and GC content of the amplicons. This method is expanding rapidly in several research areas such as human genetics, reproductive biology, microbiology and ecology/conservation of wild populations. Here we have developed a successful HRM protocol for avian sex identification based on the amplification of sex-specific CHD1 fragments. The melting curve patterns allowed efficient sexual differentiation of 111 samples analysed (plucked feathers, muscle tissues, blood and oral cavity epithelial cells) of 14 bird species. In addition, we sequenced the amplified regions of the CHD1 gene and demonstrated the usefulness of this strategy for the genotype discrimination of various amplicons (CHD1Z and CHD1W), which have small size differences, ranging from 2 bp to 44 bp. The established methodology clearly revealed the advantages (e.g. closed-tube system, high sensitivity and rapidity) of a simple HRM assay for accurate sex differentiation of the species under study. The requirements, strengths and limitations of the method are addressed to provide a simple guide for its application in the field of molecular sexing of birds. The high sensitivity and resolution relative to previous real-time PCR methods makes HRM analysis an excellent approach for improving advanced molecular methods for bird sexing. © 2013 Blackwell Publishing Ltd.
Simple, Inexpensive, and Rapid Way to Produce Bacillus subtilis Spores for the Guthrie Bioassay
Franklin, Martha L.; Clark, William A.
1981-01-01
Esculin agar has been found to be a simple, inexpensive, rapid, and reliable means to promote production of spores of inhibitor-sensitive clones of Bacillus subtilis strains ATCC 6051 and 6633 for use in the Guthrie bioassay screening tests for genetic metabolic disorders. Images PMID:6790564
Khurana, Surender; Sasono, Pretty; Fox, Annette; Nguyen, Van Kinh; Le, Quynh Mai; Pham, Quang Thai; Nguyen, Tran Hien; Nguyen, Thanh Liem; Horby, Peter; Golding, Hana
2011-12-01
Continuing evolution of highly pathogenic (HP) H5N1 influenza viruses in wild birds with transmission to domestic poultry and humans poses a pandemic threat. There is an urgent need for a simple and rapid serological diagnostic assay which can differentiate between antibodies to seasonal and H5N1 strains and that could provide surveillance tools not dependent on virus isolation and nucleic acid technologies. Here we describe the establishment of H5N1 SeroDetect enzyme-linked immunosorbent assay (ELISA) and rapid test assays based on three peptides in HA2 (488-516), PB1-F2 (2-75), and M2e (2-24) that are highly conserved within H5N1 strains. These peptides were identified by antibody repertoire analyses of H5N1 influenza survivors in Vietnam using whole-genome-fragment phage display libraries (GFPDLs). To date, both platforms have demonstrated high levels of sensitivity and specificity in detecting H5N1 infections (clade 1 and clade 2.3.4) in Vietnamese patients as early as 7 days and up to several years postinfection. H5N1 virus-uninfected individuals in Vietnam and the United States, including subjects vaccinated with seasonal influenza vaccines or with confirmed seasonal virus infections, did not react in the H5N1-SeroDetect assays. Moreover, sera from individuals vaccinated with H5N1 subunit vaccine with moderate anti-H5N1 neutralizing antibody titers did not react positively in the H5N1-SeroDetect ELISA or rapid test assays. The simple H5N1-SeroDetect ELISA and rapid tests could provide an important tool for large-scale surveillance for potential exposure to HP H5N1 strains in both humans and birds.
Jung, Seung-Yong; Notton, Timothy; Fong, Erika; ...
2015-01-07
Particle sorting using acoustofluidics has enormous potential but widespread adoption has been limited by complex device designs and low throughput. Here, we report high-throughput separation of particles and T lymphocytes (600 μL min -1) by altering the net sonic velocity to reposition acoustic pressure nodes in a simple two-channel device. Finally, the approach is generalizable to other microfluidic platforms for rapid, high-throughput analysis.
Hussain, Sahid; Won, Nayoun; Nam, Jutaek; Bang, Jiwon; Chung, Hyokyun; Kim, Sungjee
2009-07-13
True colors: High-quality InP and InP/ZnS quantum dots (QDs) are obtained by means of a simple one-pot method in the presence of polyethylene glycol (PEG). Rapid and size-controlled reactions lead to highly crystalline and nearly monodisperse QDs at relatively low temperatures. The particles emit from cyan blue to far-red, and are successfully used in cellular imaging (see figure).
Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz
2011-04-01
In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.
Keskinbora, Kahraman; Grévent, Corinne; Eigenthaler, Ulrike; Weigand, Markus; Schütz, Gisela
2013-11-26
A significant challenge to the wide utilization of X-ray microscopy lies in the difficulty in fabricating adequate high-resolution optics. To date, electron beam lithography has been the dominant technique for the fabrication of diffractive focusing optics called Fresnel zone plates (FZP), even though this preparation method is usually very complicated and is composed of many fabrication steps. In this work, we demonstrate an alternative method that allows the direct, simple, and fast fabrication of FZPs using focused Ga(+) beam lithography practically, in a single step. This method enabled us to prepare a high-resolution FZP in less than 13 min. The performance of the FZP was evaluated in a scanning transmission soft X-ray microscope where nanostructures as small as sub-29 nm in width were clearly resolved, with an ultimate cutoff resolution of 24.25 nm, demonstrating the highest first-order resolution for any FZP fabricated by the ion beam lithography technique. This rapid and simple fabrication scheme illustrates the capabilities and the potential of direct ion beam lithography (IBL) and is expected to increase the accessibility of high-resolution optics to a wider community of researchers working on soft X-ray and extreme ultraviolet microscopy using synchrotron radiation and advanced laboratory sources.
New Exact Solutions of Relativistic Hydrodynamics for Longitudinally Expanding Fireballs
NASA Astrophysics Data System (ADS)
Csörgő, Tamás; Kasza, Gábor; Csanád, Máté; Jiang, Zefang
2018-06-01
We present new, exact, finite solutions of relativistic hydrodynamics for longitudinally expanding fireballs for arbitrary constant value of the speed of sound. These new solutions generalize earlier, longitudinally finite, exact solutions, from an unrealistic to a reasonable equation of state, characterized by a temperature independent (average) value of the speed of sound. Observables like the rapidity density and the pseudorapidity density are evaluated analytically, resulting in simple and easy to fit formulae that can be matched to the high energy proton-proton and heavy ion collision data at RHIC and LHC. In the longitudinally boost-invariant limit, these new solutions approach the Hwa-Bjorken solution and the corresponding rapidity distributions approach a rapidity plateaux.
A simplified CARS measurement system for rapid determination of temperature and oxygen concentration
NASA Technical Reports Server (NTRS)
Fujii, Shoichi
1987-01-01
A new spectroscopic concept for the rapid determination of temperature and oxygen concentration by CARS (Coherent Anti-Stokes Raman Spectroscopy) was described. The ratio of two spectral regions in the broadband Q-branch spectrum was detected by photomultipliers in a monochromator, which ratio depends on temperature and species concentration. The comparison of the measured data with theory was made using a flat flame burner and an electric furnace, with reasonable results. Various optical techniques for alignment were introduced including a highly efficient, stable dye oscillator. The combination of the spectroscopic concept and the optical techniques will make the CARS measurement system rapid in data processing and simple in optical parts.
Rapid measurement of 89,90Sr radioactivity in rinse water.
Masashi, Takada; Hiroko, Enomoto; Toshikazu, Suzuki
2013-03-01
Rapid measurement of radioactivity from Sr in aqueous solutions is performed using a technique combining a strontium rad disk and a picobeta spectrometer. Identification of Sr radionuclides is accomplished in as little as 90 min in a radiation-tainted solution that contains more highly radioactive cesium. It is possible to perform triage by assessing skin exposure doses in this short time. This simple technique could be used in mobile laboratories. Sr having 1 Bq radioactivities are measured in 10 kBq Cs in aqueous solution. The radioactivity contained in rinse water used to decontaminate the feet of workers who stepped into highly contaminated water in the basement of the turbine building of Unit 3 at the Fukushima Daiichi nuclear power station was measured. The amount of Sr radioactivity in rinse water using the authors' rapid measurement technique (0.29 Bq mL) and a traditional method agree well, with 3.6% difference. Based on this agreement, this technique is confirmed to be useful for rapid measurement of Sr radioactivities.
Advances in developing rapid, reliable and portable detection systems for alcohol.
Thungon, Phurpa Dema; Kakoti, Ankana; Ngashangva, Lightson; Goswami, Pranab
2017-11-15
Development of portable, reliable, sensitive, simple, and inexpensive detection system for alcohol has been an instinctive demand not only in traditional brewing, pharmaceutical, food and clinical industries but also in rapidly growing alcohol based fuel industries. Highly sensitive, selective, and reliable alcohol detections are currently amenable typically through the sophisticated instrument based analyses confined mostly to the state-of-art analytical laboratory facilities. With the growing demand of rapid and reliable alcohol detection systems, an all-round attempt has been made over the past decade encompassing various disciplines from basic and engineering sciences. Of late, the research for developing small-scale portable alcohol detection system has been accelerated with the advent of emerging miniaturization techniques, advanced materials and sensing platforms such as lab-on-chip, lab-on-CD, lab-on-paper etc. With these new inter-disciplinary approaches along with the support from the parallel knowledge growth on rapid detection systems being pursued for various targets, the progress on translating the proof-of-concepts to commercially viable and environment friendly portable alcohol detection systems is gaining pace. Here, we summarize the progress made over the years on the alcohol detection systems, with a focus on recent advancement towards developing portable, simple and efficient alcohol sensors. Copyright © 2017 Elsevier B.V. All rights reserved.
Frauen, M; Steinhart, H; Rapp, C; Hintze, U
2001-07-01
A simple, rapid and reproducible method for identification and quantification of iodopropynyl butylcarbamate (IPBC) in different cosmetic formulations is presented. The determination was carried out using a high-performance liquid chromatography (HPLC) procedure on a reversed phase column coupled to a single quadrupole mass spectrometer (MS) via an electrospray ionization (ESI) interface. Detection was performed in the positive selected ion-monitoring mode. In methanol/water extracts from different cosmetic formulations a detection limit between 50 and 100 ng/g could be achieved. A routine analytical procedure could be set up with good quantification reliability (relative standard deviation between 0.9 and 2.9%).
Comparative analysis of multiple-casualty incident triage algorithms.
Garner, A; Lee, A; Harrison, K; Schultz, C H
2001-11-01
We sought to retrospectively measure the accuracy of multiple-casualty incident (MCI) triage algorithms and their component physiologic variables in predicting adult patients with critical injury. We performed a retrospective review of 1,144 consecutive adult patients transported by ambulance and admitted to 2 trauma centers. Association between first-recorded out-of-hospital physiologic variables and a resource-based definition of severe injury appropriate to the MCI context was determined. The association between severe injury and Triage Sieve, Simple Triage and Rapid Treatment, modified Simple Triage and Rapid Treatment, and CareFlight Triage was determined in the patient population. Of the physiologic variables, the Motor Component of the Glasgow Coma Scale had the strongest association with severe injury, followed by systolic blood pressure. The differences between CareFlight Triage, Simple Triage and Rapid Treatment, and modified Simple Triage and Rapid Treatment were not dramatic, with sensitivities of 82% (95% confidence interval [CI] 75% to 88%), 85% (95% CI 78% to 90%), and 84% (95% CI 76% to 89%), respectively, and specificities of 96% (95% CI 94% to 97%), 86% (95% CI 84% to 88%), and 91% (95% CI 89% to 93%), respectively. Both forms of Triage Sieve were significantly poorer predictors of severe injury. Of the physiologic variables used in the triage algorithms, the Motor Component of the Glasgow Coma Scale and systolic blood pressure had the strongest association with severe injury. CareFlight Triage, Simple Triage and Rapid Treatment, and modified Simple Triage and Rapid Treatment had similar sensitivities in predicting critical injury in designated trauma patients, but CareFlight Triage had better specificity. Because patients in a true mass casualty situation may not be completely comparable with designated trauma patients transported to emergency departments in routine circumstances, the best triage instrument in this study may not be the best in an actual MCI. These findings must be validated prospectively before their accuracy can be confirmed.
Coins and Costs: A Simple and Rapid Assessment of Basic Financial Knowledge
ERIC Educational Resources Information Center
Willner, Paul; Bailey, Rebecca; Dymond, Simon; Parry, Rhonwen
2011-01-01
Introduction: We describe a simple and rapid screening test for basic financial knowledge that is suitable for administration to people with mild intellectual disabilities. Method: The Coins and Costs test asks respondents to name coins, and to estimate prices of objects ranging between 1 British Pound (an ice cream) and 100K British Pounds (a…
In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...
Youn, S Y; Jeong, O M; Choi, B K; Jung, S C; Kang, M S
2017-02-01
Raw chicken products are major causes of human foodborne salmonellosis worldwide. In particular, there is a significant risk of human exposure to Salmonella originating from the chicken slaughtering process. Controlling the contamination of chicken carcasses by Salmonella has been a considerable challenge in chicken-slaughtering facilities and involves routine microbiological monitoring using reliable detection methods. Simple and rapid detection methods, particularly those capable of determining cell viability, will significantly facilitate routine monitoring of Salmonella Here, we report an invA-based loop-mediated isothermal amplification method coupled with a simple propidium monoazide treatment (PMA-LAMP) for simple and rapid detection and quantification of viable Salmonella in rinse water of chicken carcasses. In this study, PMA-LAMP consistently gave negative results for isopropanol-killed Salmonella with concentrations up to 8.0 × 10 6 CFU/reaction. The detection limit of PMA-LAMP was 8.0 × 10 1 CFU/reaction with viable Salmonella in both pure culture and rinse water of chicken carcasses, and 10-fold lower than a conventional polymerase chain reaction coupled with PMA (PMA-PCR) targeting invA There was a high correlation (R 2 = 0.99 to 0.976) between LAMP time threshold (T T ) values and viable Salmonella with a quantification range of 1.0 × 10 3 to 1.0 × 10 8 CFU/mL in pure culture and rinse water of chicken carcasses. The PMA-LAMP assay took less than 2 h to detect Salmonella contaminated in test samples. Therefore, this simple and rapid method will be a very useful tool to detect live Salmonella contamination of chicken carcasses without pre-enrichment at the slaughterhouse where sanitizing treatments are commonly used. © 2016 Poultry Science Association Inc.
Zhang, Jing; Xu, Xiao-Jie; Xu, Wen; Huang, Juan; Zhu, Da-yuan; Qiu, Xiao-Hui
2015-07-01
A simple and effective method was established for separation and characterization of flavonoid constituents in Radix Astragali (RA) by combination of ultra-high-pressure liquid chromatography with LTQ-Orbitrap tandem mass spectrometry (u-HPLC-LTQ-Orbitrap-MS(n)). For three major structural types of flavonoids, the proposed fragmentation pathways and major diagnostic fragment ions of isoflavones, pterocarpans and isoflavans were investigated to trace isoflavonoid derivatives in crude plant extracts. Based on the systematic identification strategy, 48 constituents were rapidly detected and characterized or tentatively identified, many of which were first reported in RA. The u-PHLC-LTQ-Orbitrap MS(n) platform was proved as an effective tool for rapid qualitative analysis of secondary metabolite productions from natural resources. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
An improved synthesis of pentacene: rapid access to a benchmark organic semiconductor.
Pramanik, Chandrani; Miller, Glen P
2012-04-20
Pentacene is an organic semiconductor used in a variety of thin-film organic electronic devices. Although at least six separate syntheses of pentacene are known (two from dihydropentacenes, two from 6,13-pentacenedione and two from 6,13-dihydro-6,13-dihydroxypentacene), none is ideal and several utilize elevated temperatures that may facilitate the oxidation of pentacene as it is produced. Here, we present a fast (-2 min of reaction time), simple, high-yielding (≥ 90%), low temperature synthesis of pentacene from readily available 6,13-dihydro-6,13-dihydroxypentacene. Further, we discuss the mechanism of this highly efficient reaction. With this improved synthesis, researchers gain rapid, affordable access to high purity pentacene in excellent yield and without the need for a time consuming sublimation.
Xiong, Ai-Sheng; Yao, Quan-Hong; Peng, Ri-He; Li, Xian; Fan, Hui-Qin; Cheng, Zong-Ming; Li, Yi
2004-07-07
Chemical synthesis of DNA sequences provides a powerful tool for modifying genes and for studying gene function, structure and expression. Here, we report a simple, high-fidelity and cost-effective PCR-based two-step DNA synthesis (PTDS) method for synthesis of long segments of DNA. The method involves two steps. (i) Synthesis of individual fragments of the DNA of interest: ten to twelve 60mer oligonucleotides with 20 bp overlap are mixed and a PCR reaction is carried out with high-fidelity DNA polymerase Pfu to produce DNA fragments that are approximately 500 bp in length. (ii) Synthesis of the entire sequence of the DNA of interest: five to ten PCR products from the first step are combined and used as the template for a second PCR reaction using high-fidelity DNA polymerase pyrobest, with the two outermost oligonucleotides as primers. Compared with the previously published methods, the PTDS method is rapid (5-7 days) and suitable for synthesizing long segments of DNA (5-6 kb) with high G + C contents, repetitive sequences or complex secondary structures. Thus, the PTDS method provides an alternative tool for synthesizing and assembling long genes with complex structures. Using the newly developed PTDS method, we have successfully obtained several genes of interest with sizes ranging from 1.0 to 5.4 kb.
Wang, Libing; Chen, Wei; Xu, Dinghua; Shim, Bong Sup; Zhu, Yingyue; Sun, Fengxia; Liu, Liqiang; Peng, Chifang; Jin, Zhengyu; Xu, Chuanlai; Kotov, Nicholas A.
2009-01-01
Safety of water was for a long time and still is one of the most pressing needs for many countries and different communities. Despite the fact that there are potentially many methods to evaluate water safety, finding a simple, rapid, versatile, and inexpensive method for detection of toxins in everyday items is still a great challenge. In this study, we extend the concept of composites obtained impregnation of porous fibrous materials, such as fabrics and papers, by single walled carbon-nanotubes (SWNTs) toward very simple but high-performance biosensors. They utilize the strong dependence of electrical conductivity through nanotubes percolation network on the width of nanotubes-nanotube tunneling gap and can potentially satisfy all the requirements outlined above for the routine toxin monitoring. An antibody to the microcystin-LR (MC-LR), one of the common culprits in mass poisonings, was dispersed together with SWNTs. This dispersion was used to dip-coat the paper rendering it conductive. The change in conductivity of the paper was used to sense the MC-LR in the water rapidly and accurately. The method has the linear detection range up to 10 nmol/L and non-linear detection up to 40 nmol/L. The limit of detection was found to be 0.6 nmol/L (0.6 ng/mL), which satisfies the strictest World Health Organization standard for MC-LR content in drinking water (1 ng/mL), and is comparable to the detection limit of traditional ELISA method of MC-LR detection, while drastically reducing the time of analysis by more than an order of magnitude, which is one of the major hurdles in practical applications. Similar technology of sensor preparation can also be used for a variety of other rapid environmental sensors. PMID:19928776
A facile and efficient method to modify gold nanorods with thiolated DNA at a low pH value.
Shi, Dangwei; Song, Chen; Jiang, Qiao; Wang, Zhen-Gang; Ding, Baoquan
2013-03-28
We report a simple, rapid and efficient strategy for modification of gold nanorods (AuNRs) with thiolated DNA at low solution pH and high salt concentration. DNA functionalized AuNRs were then used to assemble with DNA modified gold nanoparticles to form discrete satellite nanostructures.
USDA-ARS?s Scientific Manuscript database
Loop-mediated isothermal amplification (LAMP) is a novel simple detection technology that amplifies DNA with high speed, efficiency, and specificity under isothermal conditions. The objective of this study was to evaluate the effectiveness of 3M Molecular Detection System (MDS) and ANSR Pathogen Det...
Liu, I-Chen; Chen, Pin-Chuan; Chau, Lai-Kwan; Chang, Guo-En
2018-01-08
We propose and develop an intensity-detection-based refractive-index (RI) sensor for low-cost, rapid RI sensing. The sensor is composed of a polymer bent ridge waveguide (BRWG) structure on a low-cost glass substrate and is integrated with a microfluidic channel. Different-RI solutions flowing through the BRWG sensing region induce output optical power variations caused by optical bend losses, enabling simple and real-time RI detection. Additionally, the sensors are fabricated using rapid and cost-effective vacuum-less processes, attaining the low cost and high throughput required for mass production. A good RI solution of 5.31 10 -4 × RIU -1 is achieved from the RI experiments. This study demonstrates mass-producible and compact RI sensors for rapid and sensitive chemical analysis and biomedical sensing.
Chaumpluk, Piyasak; Plubcharoensook, Pattra; Prasongsuk, Sehanat
2016-06-01
Postharvest herbal product contamination with mycotoxins and mycotoxin-producing fungi represents a potentially carcinogenic hazard. Aspergillus flavus is a major cause of this issue. Available mold detection methods are PCR-based and rely heavily on laboratories; thus, they are unsuitable for on-site monitoring. In this study, a bendable, paper-based lab-on-a-chip platform was developed to rapidly detect toxigenic Aspergillus spp. DNA. The 3.0-4.0 cm(2) chip is fabricated using Whatman™ filter paper, fishing line and a simple plastic lamination process and has nucleic acid amplification and signal detection components. The Aspergillus assay specifically amplifies the aflatoxin biosynthesis gene, aflR, using loop-mediated isothermal amplification (LAMP); hybridization between target DNA and probes on blue silvernanoplates (AgNPls) yields colorimetric results. Positive results are indicated by the detection pad appearing blue due to dispersed blue AgNPls; negative results are indicated by the detection pad appearing colorless or pale yellow due to probe/target DNA hybridization and AgNPls aggregation. Assay completion requires less than 40 min, has a limit of detection (LOD) of 100 aflR copies, and has high specificity (94.47%)and sensitivity (100%). Contamination was identified in 14 of 32 herbal samples tested (43.75%). This work demonstrates the fabrication of a simple, low-cost, paper-based lab-on-a-chip platform suitable for rapid-detection applications. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Qiao, Tian-Min; Zhang, Jing; Li, Shu-Jiang; Han, Shan; Zhu, Tian-Hui
2016-10-01
Eucalyptus dieback disease, caused by Cylindrocladium scoparium , has occurred in last few years in large Eucalyptus planting areas in China and other countries. Rapid, simple, and reliable diagnostic techniques are desired for the early detection of Eucalyptus dieback of C. scoparium prior to formulation of efficient control plan. For this purpose, three PCR-based methods of nested PCR, multiplex PCR, loop-mediated isothermal amplification (LAMP) were developed for detection of C. scoparium based on factor 1-alpha (tef1) and beta-tubulin gene in this study. All of the three methods showed highly specific to C. scoparium . The sensitivities of the nested PCR and LAMP were much higher than the multiplex PCR. The sensitivity of multiplex PCR was also higher than regular PCR. C. scoparium could be detected within 60 min from infected Eucalyptus plants by LAMP, while at least 2 h was needed by the rest two methods. Using different Eucalyptus tissues as samples for C. scoparium detection, all of the three PCR-based methods showed much better detection results than regular PCR. Base on the results from this study, we concluded that any of the three PCR-based methods could be used as diagnostic technology for the development of efficient strategies of Eucalyptus dieback disease control. Particularly, LAMP was the most practical method in field application because of its one-step and rapid reaction, simple operation, single-tube utilization, and simple visualization of amplification products.
Qiao, Tian-Min; Zhang, Jing; Li, Shu-Jiang; Han, Shan; Zhu, Tian-Hui
2016-01-01
Eucalyptus dieback disease, caused by Cylindrocladium scoparium, has occurred in last few years in large Eucalyptus planting areas in China and other countries. Rapid, simple, and reliable diagnostic techniques are desired for the early detection of Eucalyptus dieback of C. scoparium prior to formulation of efficient control plan. For this purpose, three PCR-based methods of nested PCR, multiplex PCR, loop-mediated isothermal amplification (LAMP) were developed for detection of C. scoparium based on factor 1-alpha (tef1) and beta-tubulin gene in this study. All of the three methods showed highly specific to C. scoparium. The sensitivities of the nested PCR and LAMP were much higher than the multiplex PCR. The sensitivity of multiplex PCR was also higher than regular PCR. C. scoparium could be detected within 60 min from infected Eucalyptus plants by LAMP, while at least 2 h was needed by the rest two methods. Using different Eucalyptus tissues as samples for C. scoparium detection, all of the three PCR-based methods showed much better detection results than regular PCR. Base on the results from this study, we concluded that any of the three PCR-based methods could be used as diagnostic technology for the development of efficient strategies of Eucalyptus dieback disease control. Particularly, LAMP was the most practical method in field application because of its one-step and rapid reaction, simple operation, single-tube utilization, and simple visualization of amplification products. PMID:27721691
Kovács, G. S.; Tárnoky, K. E.
1960-01-01
A simple and rapid procedure has been developed for the complexometric titration of serum calcium and magnesium using “plasmocorinth B” as indicator. Both determinations can be carried out from the same 0.5 ml. sample. The method is in good agreement with the established calcium and magnesium methods. PMID:14411396
Zhang, Chenchu; Hu, Yanlei; Du, Wenqiang; Wu, Peichao; Rao, Shenglong; Cai, Ze; Lao, Zhaoxin; Xu, Bing; Ni, Jincheng; Li, Jiawen; Zhao, Gang; Wu, Dong; Chu, Jiaru; Sugioka, Koji
2016-01-01
Rapid integration of high-quality functional devices in microchannels is in highly demand for miniature lab-on-a-chip applications. This paper demonstrates the embellishment of existing microfluidic devices with integrated micropatterns via femtosecond laser MRAF-based holographic patterning (MHP) microfabrication, which proves two-photon polymerization (TPP) based on spatial light modulator (SLM) to be a rapid and powerful technology for chip functionalization. Optimized mixed region amplitude freedom (MRAF) algorithm has been used to generate high-quality shaped focus field. Base on the optimized parameters, a single-exposure approach is developed to fabricate 200 × 200 μm microstructure arrays in less than 240 ms. Moreover, microtraps, QR code and letters are integrated into a microdevice by the advanced method for particles capture and device identification. These results indicate that such a holographic laser embellishment of microfluidic devices is simple, flexible and easy to access, which has great potential in lab-on-a-chip applications of biological culture, chemical analyses and optofluidic devices. PMID:27619690
Ruthenium-Catalyzed Cascade Annulation of Indole with Propargyl Alcohols.
Kaufmann, Julia; Jäckel, Elisabeth; Haak, Edgar
2018-05-14
Cascade transformations forming multiple bonds and one-pot procedures provide rapid access to natural-product-like scaffolds from simple precursors. These atom-economic processes are valuable tools in organic synthesis and drug discovery. Herein, we report on ruthenium-catalyzed cascade annulations of indole with readily available propargyl alcohols. These provide rapid access to diverse carbazoles, cyclohepta[b]indoles, and further fused polycycles with high selectivity. A bifunctional ruthenium complex featuring a redox-coupled cyclopentadienone ligand acts as a common catalyst for the different cascade processes. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Richard, Vaea; Aubry, Maite
2018-05-01
Experimental studies on Zika virus (ZIKV) may require improvement of infectious titers in viral stocks obtained by cell culture amplification. The use of centrifugal filter devices to increase infectious titers of ZIKV from cell-culture supernatants is highlighted here. A mean gain of 2.33 ± 0.12 log 10 DICT 50 /mL was easily and rapidly obtained with this process. This efficient method of ultrafiltration may be applied to other viruses and be useful in various experimental studies requiring high viral titers. Copyright © 2018 Elsevier B.V. All rights reserved.
Feasibility of FT–Raman spectroscopy for rapid screening for DON toxin in ground wheat and barley.
Liu, Y; Delwiche, S R; Dong, Y
2009-10-01
Rapid detection of deoxynivalenol (DON) in cereal-based food and feed has long been the goal of regulators and manufacturers. As non-destructive approaches, infrared (IR) and near-infrared (NIR) spectroscopic techniques have been used for the prediction and classification of contaminated single-kernel and ground grain without any DON extraction steps. These methods, however, are hindered by the intense and broad spectral bands attributed to naturally occurring moisture. Raman spectroscopy could be an alternative to IR and NIR due to its insensitivity to water and fewer overlapped bands. This study explored the feasibility of the Raman technique for rapid and non-destructive screening of DON-contaminated wheat and barley meal. The advantages of this technique include the use of a 1064-nm NIR excitation laser that reduces interference from fluorescence of biological compounds in wheat and barley, the use of a simple intensity-intensity algorithm at two unique frequencies, plus the technique's ease of sample preparation. The results indicate that the simple algorithm, as well as principal component analysis applied to the Raman spectra, can be used to classify low from high DON grain.
Fructose, exercise, and health.
Johnson, Richard J; Murray, Robert
2010-01-01
The large daily energy intake common among athletes can be associated with a large daily intake of fructose, a simple sugar that has been linked to metabolic disorders. Fructose commonly is found in foods and beverages as a natural component (e.g., in fruits) or as an added ingredient (as sucrose or high fructose corn syrup [HFCS]). A growing body of research suggests that excessive intake of fructose (e.g., >50 g.d(-1)) may be linked to development of the metabolic syndrome (obesity, dyslipidemia, hypertension, insulin resistance, proinflammatory state, prothrombosis). The rapid metabolism of fructose in the liver and resultant drop in hepatic adenosine triphosphate (ATP) levels have been linked with mitochondrial and endothelial dysfunction, alterations that could predispose to obesity, diabetes, and hypertension. However, for athletes, a positive aspect of fructose metabolism is that, in combination with other simple sugars, fructose stimulates rapid fluid and solute absorption in the small intestine and helps increase exogenous carbohydrate oxidation during exercise, an important response for improving exercise performance. Although additional research is required to clarify the possible health-related implications of long-term intake of large amounts of dietary fructose among athletes, regular exercise training and consequent high daily energy expenditure may protect athletes from the negative metabolic responses associated with chronically high dietary fructose intake.
Electrolyte-free Amperometric Immunosensor using a Dendritic Nanotip†
Kim, Jong-Hoon; Hiraiwa, Morgan; Lee, Hyun-Boo; Lee, Kyong-Hoon; Cangelosi, Gerard A.; Chung, Jae-Hyun
2013-01-01
Electric detection using a nanocomponent may lead to platforms for rapid and simple biosensing. Sensors composed of nanotips or nanodots have been described for highly sensitive amperometry enabled by confined geometry. However, both fabrication and use of nanostructured sensors remain challenging. This paper describes a dendritic nanotip used as an amperometric biosensor for highly sensitive detection of target bacteria. A dendritic nanotip is structured by Si nanowires coated with single-walled carbon nanotubes (SWCNTs) for generation of a high electric field. For reliable measurement using the dendritic structure, Si nanowires were uniformly fabricated by ultraviolet (UV) lithography and etching. The dendritic structure effectively increased the electric current density near the terminal end of the nanotip according to numerical computation. The electrical characteristics of a dendritic nanotip with additional protein layers was studied by cyclic voltammetry and I–V measurement in deionized (DI) water. When the target bacteria dielectrophoretically captured onto a nanotip were bound with fluorescence antibodies, the electric current through DI water decreased. Measurement results were consistent with fluorescence- and electron microscopy. The sensitivity of the amperometry was 10 cfu/sample volume (103 cfu/mL), which was equivalent to the more laborious fluorescence measurement method. The simple configuration of a dendritic nanotip can potentially offer an electrolyte-free detection platform for sensitive and rapid biosensors. PMID:23585927
Electrolyte-free Amperometric Immunosensor using a Dendritic Nanotip.
Kim, Jong-Hoon; Hiraiwa, Morgan; Lee, Hyun-Boo; Lee, Kyong-Hoon; Cangelosi, Gerard A; Chung, Jae-Hyun
2013-01-01
Electric detection using a nanocomponent may lead to platforms for rapid and simple biosensing. Sensors composed of nanotips or nanodots have been described for highly sensitive amperometry enabled by confined geometry. However, both fabrication and use of nanostructured sensors remain challenging. This paper describes a dendritic nanotip used as an amperometric biosensor for highly sensitive detection of target bacteria. A dendritic nanotip is structured by Si nanowires coated with single-walled carbon nanotubes (SWCNTs) for generation of a high electric field. For reliable measurement using the dendritic structure, Si nanowires were uniformly fabricated by ultraviolet (UV) lithography and etching. The dendritic structure effectively increased the electric current density near the terminal end of the nanotip according to numerical computation. The electrical characteristics of a dendritic nanotip with additional protein layers was studied by cyclic voltammetry and I-V measurement in deionized (DI) water. When the target bacteria dielectrophoretically captured onto a nanotip were bound with fluorescence antibodies, the electric current through DI water decreased. Measurement results were consistent with fluorescence- and electron microscopy. The sensitivity of the amperometry was 10 cfu/sample volume (10 3 cfu/mL), which was equivalent to the more laborious fluorescence measurement method. The simple configuration of a dendritic nanotip can potentially offer an electrolyte-free detection platform for sensitive and rapid biosensors.
Choi, Sae Byeol; You, Jiyoung; Choi, Sang Yong
2012-01-10
Traumatic pancreaticoduodenal injury still remains challenging with high morbidity and mortality. Optimal management by performing simple and fast damage control surgery ensures better outcomes. A 36-year-old man was admitted with a combined pancreaticoduodenal injury after being assaulted. More than 80% of duodenal circumference (first portion) was disrupted and the neck of the pancreas was transected. Primary repair of the duodenum and pancreaticogastrostomy were performed. The stump of the proximal pancreatic duct was also sutured. The patient developed an intra-abdominal abscess with pancreatic fistula that eventually recovered by conservative treatment. Pancreaticogastrostomy can be a treatment option for pancreatic transection. Rapid and simple damage control surgery with functional preservation of the organ will be beneficial for trauma patients.
Highly selective rhodium catalyzed domino C-H activation/cyclizations.
Trans, Duc N; Cramer, Nicolai
2011-01-01
The direct functionalization of carbon-hydrogen bonds is an emerging tool to establish more sustainable and efficient synthetic methods. We present its implementation in a cascade reaction that provides a rapid assembly of functionalized indanylamines from simple and readily available starting materials. Careful choice of the ancillary ligand---an electron-rich bidentate phosphine ligand--enables highly diastereoselective rhodium(i)-catalyzed intramolecular allylations of unsubstituted ketimines induced by a directed C-H bond activation and allene carbo-metalation sequence.
Scheel, Christina M.; Samayoa, Blanca; Herrera, Alejandro; Lindsley, Mark D.; Benjamin, Lynette; Reed, Yvonne; Hart, John; Lima, Sandra; Rivera, Blanca E.; Raxcaco, Gabriella; Chiller, Tom; Arathoon, Eduardo; Gómez, Beatriz L.
2009-01-01
Histoplasma capsulatum infection causes significant morbidity and mortality in human immunodeficiency virus-infected individuals, particularly those in countries with limited access to rapid diagnostics or antiretroviral therapies. The fungus easily disseminates in persons with AIDS, resulting in progressive disseminated histoplasmosis (PDH), which can progress rapidly to death if undiagnosed. The availability of a simple, rapid method to detect H. capsulatum infection in less developed countries where the infection is endemic would dramatically decrease the time to diagnosis and treatment of PDH. We have developed an antigen-capture enzyme-linked immunosorbent assay (ELISA) to detect PDH antigenuria in infected patients. The assay uses polyclonal antibodies against H. capsulatum as both capture and detection reagents, and a standard reference curve is included to quantify antigenuria and ensure reproducibility. We evaluated this assay using specimens collected from patients with AIDS and culture-proven histoplasmosis in a Guatemalan clinic (n = 48), from healthy persons (n = 83), and from patients with other, nonhistoplasmosis diseases (n = 114). The ELISA demonstrated a sensitivity of 81% and a specificity of 95% in detecting H. capsulatum antigen in urine. This assay relies on simple technology that can be performed in institutions with limited resources. Use of this test will facilitate rapid diagnosis of PDH in countries where mortality is high, expediting treatment and likely reducing PDH-related mortality. PMID:19357311
Wang, H; Sun, M; Xu, D; Podok, P; Xie, J; Jiang, Ys; Lu, Lq
2018-05-28
Herpesviral haematopoietic necrosis (HVHN), caused by cyprinid herpesvirus 2 (CyHV-2), causes significant losses in crucian carp (Carassius carassius) aquaculture. Rapid and convenient DNA assay detection of CyHV-2 is useful for field diagnosis. Recombinase polymerase amplification (RPA) is a novel isothermal DNA amplification and detection technology that can amplify DNA within 30 min at ~37°C by simulating in vivo DNA recombination. Herein, a rapid and convenient detection assay based on RPA with a lateral flow dipstick (LFD) was developed for detecting CyHV-2. The highly conserved ORF72 of CyHV-2 was targeted by specific and sensitive primers and probes. The optimized assay takes only 15 min at 38°C using a water bath, with analysis of products by 2% agarose gel electrophoresis within 30 min. A simple lateral flow strip based on the unique probe in reaction buffer was developed for visualization. The entire RPA-LFD assay takes 50 min less than the routine PCR method, is 100 times more sensitive and displays no cross-reaction with other aquatic viruses. The combined isothermal RPA and lateral flow assay (RPA-LFD) provides a simple, rapid, reliable method that could improve field diagnosis of CyHV-2 when resources are limited. © 2018 John Wiley & Sons Ltd.
Nicklas Samils; Malin Elfstrand; Daniel L. Lindner Czederpiltz; Jan Fahleson; Ake Olson; Christina Dixelius; Jan Stenlid
2006-01-01
Heterobasidion annosum causes root and butt-rot in trees and is the most serious forest pathogen in the northern hemisphere. We developed a rapid and simple Agrobacterium-mediated method of gene delivery into H. annosum to be used in functional studies of candidate genes and for visualization of mycelial interactions. Heterobasidion annosum TC 32-1 was cocultivated at...
ERIC Educational Resources Information Center
Homem, Vera; Alves, Arminda; Santos, Lu´cia
2014-01-01
A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass…
ERIC Educational Resources Information Center
Pizauro, Joao M., Jr.; Ferro, Jesus A.; de Lima, Andrea C. F.; Routman, Karina S.; Portella, Maria Celia
2004-01-01
The present research describes an efficient procedure to obtain high levels of trypsinogen and chymotrypsinogen by using a simple, rapid, and easily reproducible method. The extraction process and the time-course of activation of zymogens can be carried out in a single laboratory period, without sophisticated equipment. The main objective was to…
Lei, Ruirui; Wu, Yong; Dong, Suzhen; Jia, Kaili; Liu, Shunying; Hu, Wenhao
2017-03-17
A highly diasetereoselective Mannich-type multicomponent reaction was developed to rapidly construct alkynylamide-substituted α,β-diamino acid derivatives from simple starting materials under mild conditions in moderate to good yields for hit hunting. Most of the resulting products 4 exhibited good anticancer activity in HCT116, BEL7402, and SMMC7721 cells.
Identification of novel IP receptor agonists using historical ligand biased chemical arrays.
McKeown, Stephen C; Charlton, Steven J; Cox, Brian; Fitch, Helen; Howson, Christopher D; Leblanc, Catherine; Meyer, Arndt; Rosethorne, Elizabeth M; Stanley, Emily
2014-05-15
By considering published structural information we have designed high throughput biaryl lipophilic acid arrays leveraging facile chemistry to expedite their synthesis. We rapidly identified multiple hits which were of suitable IP agonist potency. These relatively simple and strategically undecorated molecules present an ideal opportunity for optimization towards our target candidate profile. Copyright © 2014 Elsevier Ltd. All rights reserved.
A simple and rapid DNA extraction method for Chlamydia trachomatis detection from urogenital swabs.
Butzler, Matthew A; Reed, Jennifer L; McFall, Sally M
2017-11-01
A highly sensitive and specific Chlamydia trachomatis (CT) diagnostic test was developed by combining filtration isolation of nucleic acid (FINA) extraction with quantitative polymerase chain reaction including an internal control to identify test inhibition. A pilot study of 40 clinical specimens yielded 100% sensitivity and specificity. Copyright © 2017 Elsevier Inc. All rights reserved.
Behbahani, Mohammad; Najafi, Fatemeh; Bagheri, Saman; Bojdi, Majid Kalate; Hassanlou, Parmoon Ghareh; Bagheri, Akbar
2014-04-01
A simple, rapid, and efficient sample pretreatment technique, based on solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and trace detection of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in water and urine samples. Some parameters such as acidity of solution, the amount of salt, type, and volume of extraction solvents, type of disperser/de-emulsifier solvent, and its volume were investigated and optimized. Under optimum extraction conditions, the limits of detections (LODs) of this method for MCPA and 2,4-D were 0.2 and 0.6 μg L(-1) (based on 3S(b)/m) in water and 0.4 and 1.6 μg L(-1) in urine, respectively. Furthermore, dynamic linear range of this method for MCPA and 2,4-D was 1-300 and 2-400 μg L(-1), repectively. Finally, the applicability of the proposed method was evaluated by extraction and determination of the herbicides in urine and different water samples.
Design of nuclease-based target recycling signal amplification in aptasensors.
Yan, Mengmeng; Bai, Wenhui; Zhu, Chao; Huang, Yafei; Yan, Jiao; Chen, Ailiang
2016-03-15
Compared with conventional antibody-based immunoassay methods, aptasensors based on nucleic acid aptamer have made at least two significant breakthroughs. One is that aptamers are more easily used for developing various simple and rapid homogeneous detection methods by "sample in signal out" without multi-step washing. The other is that aptamers are more easily employed for developing highly sensitive detection methods by using various nucleic acid-based signal amplification approaches. As many substances playing regulatory roles in physiology or pathology exist at an extremely low concentration and many chemical contaminants occur in trace amounts in food or environment, aptasensors for signal amplification contribute greatly to detection of such targets. Among the signal amplification approaches in highly sensitive aptasensors, the nuclease-based target recycling signal amplification has recently become a research focus because it shows easy design, simple operation, and rapid reaction and can be easily developed for homogenous assay. In this review, we summarized recent advances in the development of various nuclease-based target recycling signal amplification with the aim to provide a general guide for the design of aptamer-based ultrasensitive biosensing assays. Copyright © 2015 Elsevier B.V. All rights reserved.
Jin, Yulong; Huang, Yanyan; Liu, Guoquan; Zhao, Rui
2013-09-21
A novel quartz crystal microbalance (QCM) sensor for rapid, highly selective and sensitive detection of copper ions was developed. As a signal amplifier, gold nanoparticles (Au NPs) were self-assembled onto the surface of the sensor. A simple dip-and-dry method enabled the whole detection procedure to be accomplished within 20 min. High selectivity of the sensor towards copper ions is demonstrated by both individual and coexisting assays with interference ions. This gold nanoparticle mediated amplification allowed a detection limit down to 3.1 μM. Together with good repeatability and regeneration, the QCM sensor was also applied to the analysis of copper contamination in drinking water. This work provides a flexible method for fabricating QCM sensors for the analysis of important small molecules in environmental and biological samples.
Micropropagation of African violet (Saintpaulia ionantha Wendl.).
Shukla, Mukund; Sullivan, J Alan; Jain, Shri Mohan; Murch, Susan J; Saxena, Praveen K
2013-01-01
Micropropagation is an important tool for rapid multiplication and the creation of genetic variability in African violets (Saintpaulia ionantha Wendl.). Successful in vitro propagation depends on the specific requirements and precise manipulation of various factors such as the type of explants used, physiological state of the mother plant, plant growth regulators in the culture medium, and growth conditions. Development of cost-effective protocols with a high rate of multiplication is a crucial requirement for commercial application of micropropagation. The current chapter describes an optimized protocol for micropropagation of African violets using leaf explants obtained from in vitro grown plants. In this process, plant regeneration occurs via both somatic embryogenesis and shoot organogenesis simultaneously in the explants induced with the growth regulator thidiazuron (TDZ; N-phenyl-N'-1,2,3-thidiazol-5-ylurea). The protocol is simple, rapid, and efficient for large-scale propagation of African violet and the dual routes of regeneration allow for multiple applications of the technology from simple clonal propagation to induction or selection of variants to the production of synthetic seeds.
Scaling behavior of ground-state energy cluster expansion for linear polyenes
NASA Astrophysics Data System (ADS)
Griffin, L. L.; Wu, Jian; Klein, D. J.; Schmalz, T. G.; Bytautas, L.
Ground-state energies for linear-chain polyenes are additively expanded in a sequence of terms for chemically relevant conjugated substructures of increasing size. The asymptotic behavior of the large-substructure limit (i.e., high-polymer limit) is investigated as a means of characterizing the rapidity of convergence and consequent utility of this energy cluster expansion. Consideration is directed to computations via: simple Hückel theory, a refined Hückel scheme with geometry optimization, restricted Hartree-Fock self-consistent field (RHF-SCF) solutions of fixed bond-length Parisier-Parr-Pople (PPP)/Hubbard models, and ab initio SCF approaches with and without geometry optimization. The cluster expansion in what might be described as the more "refined" approaches appears to lead to qualitatively more rapid convergence: exponentially fast as opposed to an inverse power at the simple Hückel or SCF-Hubbard levels. The substructural energy cluster expansion then seems to merit special attention. Its possible utility in making accurate extrapolations from finite systems to extended polymers is noted.
Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu
2014-12-01
In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations <10%. The overall recoveries are in the range of 98-103% in chili powder and in the range of 87-100% in chili oil depending on the concentration of rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.
Rapid determination of minoxidil in human plasma using ion-pair HPLC.
Zarghi, A; Shafaati, A; Foroutan, S M; Khoddam, A
2004-10-29
A rapid, simple and sensitive ion-pair high-performance liquid chromatography (HPLC) method has been developed for quantification of minoxidil in plasma. The assay enables the measurement of minoxidil for therapeutic drug monitoring with a minimum detectable limit of 0.5 ng ml(-1). The method involves simple, one-step extraction procedure and analytical recovery was complete. The separation was performed on an analytical 150 x 4.6 mm i.d. microbondapak C18 column. The wavelength was set at 281 nm. The mobile phase was a mixture of 0.01 M sodium dihydrogen phosphate buffer and acetonitrile (60:40, v/v) containing 2.5 mM sodium dodecyl sulphate adjusted to pH 3.5 at a flow rate of 1 ml/min. The column temperature was set at 50 degrees C. The calibration curve was linear over the concentration range 2-100 ng ml(-1). The coefficients of variation for inter-day and intra-day assay were found to be less than 8%.
Analysis on the DNA Fingerprinting of Aspergillus Oryzae Mutant Induced by High Hydrostatic Pressure
NASA Astrophysics Data System (ADS)
Wang, Hua; Zhang, Jian; Yang, Fan; Wang, Kai; Shen, Si-Le; Liu, Bing-Bing; Zou, Bo; Zou, Guang-Tian
2011-01-01
The mutant strains of aspergillus oryzae (HP300a) are screened under 300 MPa for 20 min. Compared with the control strains, the screened mutant strains have unique properties such as genetic stability, rapid growth, lots of spores, and high protease activity. Random amplified polymorphic DNA (RAPD) and inter simple sequence repeats (ISSR) are used to analyze the DNA fingerprinting of HP300a and the control strains. There are 67.9% and 51.3% polymorphic bands obtained by these two markers, respectively, indicating significant genetic variations between HP300a and the control strains. In addition, comparison of HP300a and the control strains, the genetic distances of random sequence and simple sequence repeat of DNA are 0.51 and 0.34, respectively.
Rahimi, Frashta; Goire, Namraj; Guy, Rebecca; Kaldor, John M; Ward, James; Nissen, Michael D; Sloots, Theo P; Whiley, David M
2013-08-01
Background Rapid point-of-care tests (POCTs) for chlamydia (Chlamydia trachomatis) and gonorrhoea (Neisseria gonorrhoeae) have the potential to confer health benefits in certain populations even at moderate sensitivities; however, suitable POCTs for these organisms are currently lacking. In this study, we investigated the use of direct urine polymerase chain reaction (PCR), with the view of implementing a simplified PCR strategy for high-throughput chlamydia and gonorrhoea screening in remote settings. Briefly, a simple dilution of the urine was performed before adding it directly to a real-time PCR reaction. The method was evaluated using 134 stored urine specimens that had been submitted for chlamydia and gonorrhoea testing and had been tested using a commercial C. trachomatis and N. gonorrhoeae PCR method. These included samples that were PCR-positive for chlamydia (n=87), gonorrhoea (n=16) or both (n=2). Direct urine testing was conducted using previously described in-house real-time PCR methods for C. trachomatis and N. gonorrhoeae as well as for recognised N.gonorrhoeae antimicrobial resistance mechanisms. The overall sensitivities and specificities of the direct urine PCR were 78% and 100% for chlamydia, and 83% and 100% for gonorrhoea. N.gonorrhoeae penicillin and quinolone resistance mechanisms were characterised in 14 of the 18 N. gonorrhoeae-positive samples. The results of this study show that the simplified PCR strategy may be a feasible approach for rapid screening and improving chlamydia and gonorrhoea treatment in remote settings.
Kojima, Hiroyuki; Takeuchi, Shinji; Iida, Mitsuru; Nakayama, Shoji F; Shiozaki, Takuya
2018-03-01
In developing countries in Asia, such as China, Vietnam, and Thailand, there is a strong need for the development of relatively rapid and low-cost bioassays for the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food samples. These compounds are known to induce a variety of toxic and biological effects through their ligand-specific binding of the aryl hydrocarbon receptor (AhR). Indeed, several AhR-mediated reporter gene assays are widely used as prescreening tools for high-resolution gas chromatography/high-resolution mass spectrometry (HRGC-HRMS) analysis, which individually measures 17 PCDD/Fs and 12 DL-PCBs. In 2008, we have developed a new sensitive and rapid reporter gene assay using a genetically engineered stable cell line, designated DR-EcoScreen cells. The DR-EcoScreen assay using these cells has a number of great advantages of its sensitivity to 2,3,7,8-tetrachlorodibenzo-p-dioxin and its simple procedure, which shows little variance in the data (within CV 10 %) compared to other reporter gene assays. In this review, we summarize the application of the DR-EcoScreen assay to the determination of PCDD/Fs and DL-PCBs in ambient air samples, in fish and shellfish samples, and in flue gas samples from incinerators and provide potential usefulness of this bioassay for the determination of PCDD/Fs and DL-PCBs in various matrices.
Kim, Sung Hyun; Tramontina, Vinicius Augusto; Papalexiou, Vula; Luczyszyn, Sônia Mara; Grassi, Maria Bibiana; de Fatima Scarpim, Maria; Tanaka, Orlando Motohiro
2011-03-01
A multidisciplinary treatment of a case of subgingival fracture in a maxillary anterior tooth is presented. This case report describes a simple method involving an interocclusal appliance and an elastic band for rapid orthodontic extrusion to reestablish biologic width. In addition, a simple technique for surgical recontouring following the coronal displacement of the gingival margin prior to restoration of fractured tooth is explained.
A simple, rapid and inexpensive screening method for the identification of Pythium insidiosum.
Tondolo, Juliana Simoni Moraes; Loreto, Erico Silva; Denardi, Laura Bedin; Mario, Débora Alves Nunes; Alves, Sydney Hartz; Santurio, Janio Morais
2013-04-01
Growth of Pythium insidiosum mycelia around minocycline disks (30μg) did not occur within 7days of incubation at 35°C when the isolates were grown on Sabouraud, corn meal, Muller-Hinton or RPMI agar. This technique offers a simple and rapid method for the differentiation of P. insidiosum from true filamentous fungi. Copyright © 2013 Elsevier B.V. All rights reserved.
Ng, Tsz-Tsun; So, Pui-Kin; Zheng, Bo; Yao, Zhong-Ping
2015-07-16
Authentication of edible oils is a long-term issue in food safety, and becomes particularly important with the emergence and wide spread of gutter oils in recent years. Due to the very high analytical demand and diversity of gutter oils, a high throughput analytical method and a versatile strategy for authentication of mixed edible oils and gutter oils are highly desirable. In this study, an improved matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for direct analysis of edible oils. This method involved on-target sample loading, automatic data acquisition and simple data processing. MALDI-MS spectra with high quality and high reproducibility have been obtained using this method, and a preliminary spectral database of edible oils has been set up. The authenticity of an edible oil sample can be determined by comparing its MALDI-MS spectrum and principal component analysis (PCA) results with those of its labeled oil in the database. This method is simple and the whole process only takes several minutes for analysis of one oil sample. We demonstrated that the method was sensitive to change in oil compositions and can be used for measuring compositions of mixed oils. The capability of the method for determining mislabeling enables it for rapid screening of gutter oils since fraudulent mislabeling is a common feature of gutter oils. Copyright © 2015 Elsevier B.V. All rights reserved.
Su, Zi Dan; Shi, Cheng Yin; Huang, Jie; Shen, Gui Ming; Li, Jin; Wang, Sheng Qiang; Fan, Chao
2015-09-26
Red-spotted grouper nervous necrosis virus (RGNNV) is an important pathogen that causes diseases in many species of fish in marine aquaculture. The larvae and juveniles are more easily infected by RGNNV and the cumulative mortality is as high as 100 % after being infected with RGNNV. This virus imposes a serious threat to aquaculture of grouper fry. This study aimed to establish a simple, accurate and highly sensitive method for rapid detection of RGNNV on the spot. In this study, the primers specifically targeting RGNNV were designed and cross-priming isothermal amplification (CPA) system was established. The product amplified by CPA was detected through visualization with lateral flow dipstick (LFD). Three important parameters, including the amplification temperature, the concentration of dNTPs and the concentration of Mg(2+) for the CPA system, were optimized. The sensitivity and specificity of this method for RGNNV were tested and compared with those of the conventional RT-PCR and real-time quantitative RT-PCR (qRT-PCR). The optimized conditions for the CPA amplification system were determined as follows: the optimal amplification temperature, the optimized concentration of dNTPs and the concentration for Mg(2+) were 69 °C, 1.2 mmol/L and 5 mmol/L, respectively. The lowest limit of detection (LLOD) of this method for RGNNV was 10(1) copies/μL of RNA sample, which was 10 times lower than that of conventional RT-PCR and comparable to that of RT-qPCR. This method was specific for RGNNV in combination with SJNNV and had no cross-reactions with 8 types of virus and bacterial strains tested. This method was successfully applied to detect RGNNV in fish samples. This study established a CPA-LFD method for detection of RGNNV. This method is simple and rapid with high sensitivity and good specificity and can be widely applied for rapid detection of this virus on the spot.
Graphene-based porous silica sheets impregnated with polyethyleneimine for superior CO2 capture.
Yang, Shubin; Zhan, Liang; Xu, Xiaoyue; Wang, Yanli; Ling, Licheng; Feng, Xinliang
2013-04-18
It is demonstrated that graphene-based porous silica sheets can serve as an efficient carrier support for PEI via a simple nanocasting technology. The resulting materials possess thin nature, high PEI loading content and high thermal-conductivity. Such features are favorable for the efficient diffusion and adsorption of CO2 as well as the rapid thermal transfer during the CO2 capture process. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tie, Zhang; Chunguang, Wang; Xiaoyuan, Wei; Xinghua, Zhao; Xiuhui, Zhong
2012-01-01
To develop a rapid detection method of Staphylococcus aureus using loop-mediated isothermal amplification (LAMP), four specific primers were designed according to six distinct sequences of the nuc gene. In addition, the specificity and sensitivity of LAMP were verified and compared with those of PCR. Results showed that the LAMP reaction was completed within 45 min at 62.5°C, and ladder bands were appeared in LAMP products analyzed by gel electrophoresis. After adding 1x SYBR Green l, the positive reaction tube showed green color and the negative reaction tube remained orange, indicating that the LAMP has high specificity. The minimal detectable concentration of LAMP was 1 × 10² CFU/mL and that of PCR was 1 × 10⁴ CFU/mL, indicating that the LAMP was 100 times more sensitive than the PCR. The LAMP method for detection of Staphylococcus aureus has many advantages, such as simple operation, high sensitivity, high specificity, and rapid analysis. Therefore, this method is more suitable for the rapid on-site detection of Staphylococcus aureus.
Weissenberg, M; Schaeffler, I; Menagem, E; Barzilai, M; Levy, A
1997-01-03
A simple, rapid high-performance liquid chromatography method has been devised in order to separate and quantify the xanthophylls capsorubin and capasanthin present in red pepper (Capsicum annuum L.) fruits and preparations made from them (paprika and oleoresin). A reversed-phase isocratic non-aqueous system allows the separation of xanthophylls within a few minutes, with detection at 450 nm, using methyl red as internal standard to locate the various carotenoids and xanthophylls found in plant extracts. The selection of extraction solvents, mild saponification conditions, and chromatographic features is evaluated and discussed. The method is proposed for rapid screening of large plant populations, plant selection, as well as for paprika products and oleoresin, and also for nutrition and quality control studies.
Simple scale interpolator facilitates reading of graphs
NASA Technical Reports Server (NTRS)
Fetterman, D. E., Jr.
1965-01-01
Simple transparent overlay with interpolation scale facilitates accurate, rapid reading of graph coordinate points. This device can be used for enlarging drawings and locating points on perspective drawings.
Rao, Longshi; Tang, Yong; Li, Zongtao; Ding, Xinrui; Liang, Guanwei; Lu, Hanguang; Yan, Caiman; Tang, Kairui; Yu, Binhai
2017-12-01
Rapidly obtaining strong photoluminescence (PL) of carbon dots with high stability is crucial in all practical applications of carbon dots, such as cell imaging and biological detection. In this study, we proposed a rapid, continuous carbon dots synthesis technique by using a microreactor method. By taking advantage of the microreactor, we were able to rapidly synthesized CDs at a large scale in less than 5min, and a high quantum yield of 60.1% was achieved. This method is faster and more efficient than most of the previously reported methods. To explore the relationship between the microreactor structure and CDs PL properties, Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS) were carried out. The results show the surface functional groups and element contents influence the PL emission. Subsequent ion detection experiments indicated that CDs are very suitable for use as nanoprobes for Fe 3+ ion detection, and the lowest detection limit for Fe 3+ is 0.239μM, which is superior to many other research studies. This rapid and simple synthesis method will not only aid the development of the quantum dots industrialization but also provide a powerful and portable tool for the rapid and continuous online synthesis of quantum dots supporting their application in cell imaging and safety detection. Copyright © 2017 Elsevier B.V. All rights reserved.
Rapid microscale in-gel processing and digestion of proteins using surface acoustic waves.
Kulkarni, Ketav P; Ramarathinam, Sri H; Friend, James; Yeo, Leslie; Purcell, Anthony W; Perlmutter, Patrick
2010-06-21
A new method for in-gel sample processing and tryptic digestion of proteins is described. Sample preparation, rehydration, in situ digestion and peptide extraction from gel slices are dramatically accelerated by treating the gel slice with surface acoustic waves (SAWs). Only 30 minutes total workflow time is required for this new method to produce base peak chromatograms (BPCs) of similar coverage and intensity to those observed for traditional processing and overnight digestion. Simple set up, good reproducibility, excellent peptide recoveries, rapid turnover of samples and high confidence protein identifications put this technology at the fore-front of the next generation of proteomics sample processing tools.
Rapid adhesive bonding of advanced composites and titanium
NASA Technical Reports Server (NTRS)
Stein, B. A.; Tyeryart, J. R.; Hodgest, W. T.
1985-01-01
Rapid adhesive bonding (RAB) concepts utilize a toroid induction technique to heat the adhesive bond line directly. This technique was used to bond titanium overlap shear specimens with 3 advanced thermoplastic adhesives and APC-2 (graphite/PEEK) composites with PEEK film. Bond strengths equivalent to standard heated-platen press bonds were produced with large reductions in process time. RAB produced very strong bonds in APC-2 adherend specimens; the APC-2 adherends were highly resistant to delamination. Thermal cycling did not significantly affect the shear strengths of RAB titanium bonds with polyimide adhesives. A simple ultrasonic non-destructive evaluation process was found promising for evaluating bond quality.
Peng, Huan; Long, Haibo; Huang, Wenkun; Liu, Jing; Cui, Jiangkuan; Kong, Lingan; Hu, Xianqi; Gu, Jianfeng; Peng, Deliang
2017-01-01
The northern root-knot nematode (Meloidogyne hapla) is a damaging nematode that has caused serious economic losses worldwide. In the present study, a sensitive, simple and rapid method was developed for detection of M. hapla in infested plant roots by combining a Flinders Technology Associates (FTA) card with loop-mediated isothermal amplification (LAMP). The specific primers of LAMP were designed based on the distinction of internal transcribed spacer (ITS) sequences between M. hapla and other Meloidogyne spp. The LAMP assay can detect nematode genomic DNA at concentrations low to 1/200 000, which is 100 times more sensitive than conventional PCR. The LAMP was able to highly specifically distinguish M. hapla from other closely related nematode species. Furthermore, the advantages of the FTA-LAMP assay to detect M. hapla were demonstrated by assaying infected root galls that were artificially inoculated. In addition, M. hapla was successfully detected from six of forty-two field samples using FTA-LAMP technology. This study was the first to provide a simple diagnostic assay for M. hapla using the LAMP assay combined with FTA technology. In conclusion, the new FTA-LAMP assay has the potential for diagnosing infestation in the field and managing the pathogen M. hapla. PMID:28368036
Peng, Huan; Long, Haibo; Huang, Wenkun; Liu, Jing; Cui, Jiangkuan; Kong, Lingan; Hu, Xianqi; Gu, Jianfeng; Peng, Deliang
2017-04-03
The northern root-knot nematode (Meloidogyne hapla) is a damaging nematode that has caused serious economic losses worldwide. In the present study, a sensitive, simple and rapid method was developed for detection of M. hapla in infested plant roots by combining a Flinders Technology Associates (FTA) card with loop-mediated isothermal amplification (LAMP). The specific primers of LAMP were designed based on the distinction of internal transcribed spacer (ITS) sequences between M. hapla and other Meloidogyne spp. The LAMP assay can detect nematode genomic DNA at concentrations low to 1/200 000, which is 100 times more sensitive than conventional PCR. The LAMP was able to highly specifically distinguish M. hapla from other closely related nematode species. Furthermore, the advantages of the FTA-LAMP assay to detect M. hapla were demonstrated by assaying infected root galls that were artificially inoculated. In addition, M. hapla was successfully detected from six of forty-two field samples using FTA-LAMP technology. This study was the first to provide a simple diagnostic assay for M. hapla using the LAMP assay combined with FTA technology. In conclusion, the new FTA-LAMP assay has the potential for diagnosing infestation in the field and managing the pathogen M. hapla.
Zarei, Omid; Dastmalchi, Siavoush; Hamzeh-Mivehroud, Maryam
2016-01-01
Yeasts, especially Saccharomyces cerevisiae, are one of the oldest organisms with broad spectrum of applications, owing to their unique genetics and physiology. Yeast extract, i.e. the product of yeast cells, is extensively used as nutritional resource in bacterial culture media. The aim of this study was to develop a simple, rapid and cost benefit process to produce the yeast extract. In this procedure mechanical methods such as high temperature and pressure were utilized to produce the yeast extract. The growth of the bacteria feed with the produced yeast extract was monitored in order to assess the quality of the product. The results showed that the quality of the produced yeast extract was very promising concluded from the growth pattern of bacterial cells in media prepared from this product and was comparable with that of the three commercial yeast extracts in terms of bacterial growth properties. One of the main advantages of the current method was that no chemicals and enzymes were used, leading to the reduced production cost. The method is very simple and cost effective, and can be performed in a reasonable time making it suitable for being adopted by research laboratories. Furthermore, it can be scaled up to produce large quantities for industrial applications. PMID:28243289
NASA Technical Reports Server (NTRS)
Englander, Jacob
2016-01-01
This set of tutorial slides is an introduction to the Evolutionary Mission Trajectory Generator (EMTG), NASA Goddard Space Flight Center's autonomous tool for preliminary design of interplanetary missions. This slide set covers the basics of creating and post-processing simple interplanetary missions in EMTG using both high-thrust chemical and low-thrust electric propulsion along with a variety of operational constraints.
Synergetic approach for simple and rapid conjugation of gold nanoparticles with oligonucleotides.
Li, Jiuxing; Zhu, Binqing; Yao, Xiujie; Zhang, Yicong; Zhu, Zhi; Tu, Song; Jia, Shasha; Liu, Rudi; Kang, Huaizhi; Yang, Chaoyong James
2014-10-08
Attaching thiolated DNA on gold nanoparticles (AuNPs) has been extremely important in nanobiotechnology because DNA-AuNPs combine the programmability and molecular recognition properties of the biopolymers with the optical, thermal, and catalytic properties of the inorganic nanomaterials. However, current standard protocols to attach thiolated DNA on AuNPs involve time-consuming, tedious steps and do not perform well for large AuNPs, thereby greatly restricting applications of DNA-AuNPs. Here we demonstrate a rapid and facile strategy to attach thiolated DNA on AuNPs based on the excellent stabilization effect of mPEG-SH on AuNPs. AuNPs are first protected by mPEG-SH in the presence of Tween 20, which results in excellent stability of AuNPs in high ionic strength environments and extreme pHs. A high concentration of NaCl can be applied to the mixture of DNA and AuNP directly, allowing highly efficient DNA attachment to the AuNP surface by minimizing electrostatic repulsion. The entire DNA loading process can be completed in 1.5 h with only a few simple steps. DNA-loaded AuNPs are stable for more than 2 weeks at room temperature, and they can precisely hybridize with the complementary sequence, which was applied to prepare core-satellite nanostructures. Moreover, cytotoxicity assay confirmed that the DNA-AuNPs synthesized by this method exhibit lower cytotoxicity than those prepared by current standard methods. The proposed method provides a new way to stabilize AuNPs for rapid and facile loading thiolated DNA on AuNPs and will find wide applications in many areas requiring DNA-AuNPs, including diagnosis, therapy, and imaging.
Engineered nanoconstructs for the multiplexed and sensitive detection of high-risk pathogens
NASA Astrophysics Data System (ADS)
Seo, Youngmin; Kim, Ji-Eun; Jeong, Yoon; Lee, Kwan Hong; Hwang, Jangsun; Hong, Jongwook; Park, Hansoo; Choi, Jonghoon
2016-01-01
Many countries categorize the causative agents of severe infectious diseases as high-risk pathogens. Given their extreme infectivity and potential to be used as biological weapons, a rapid and sensitive method for detection of high-risk pathogens (e.g., Bacillus anthracis, Francisella tularensis, Yersinia pestis, and Vaccinia virus) is highly desirable. Here, we report the construction of a novel detection platform comprising two units: (1) magnetic beads separately conjugated with multiple capturing antibodies against four different high-risk pathogens for simple and rapid isolation, and (2) genetically engineered apoferritin nanoparticles conjugated with multiple quantum dots and detection antibodies against four different high-risk pathogens for signal amplification. For each high-risk pathogen, we demonstrated at least 10-fold increase in sensitivity compared to traditional lateral flow devices that utilize enzyme-based detection methods. Multiplexed detection of high-risk pathogens in a sample was also successful by using the nanoconstructs harboring the dye molecules with fluorescence at different wavelengths. We ultimately envision the use of this novel nanoprobe detection platform in future applications that require highly sensitive on-site detection of high-risk pathogens.
Ooka, Tadasuke; Terajima, Jun; Kusumoto, Masahiro; Iguchi, Atsushi; Kurokawa, Ken; Ogura, Yoshitoshi; Asadulghani, Md; Nakayama, Keisuke; Murase, Kazunori; Ohnishi, Makoto; Iyoda, Sunao; Watanabe, Haruo; Hayashi, Tetsuya
2009-09-01
Enterohemorrhagic Escherichia coli O157 (EHEC O157) is a food-borne pathogen that has raised worldwide public health concern. The development of simple and rapid strain-typing methods is crucial for the rapid detection and surveillance of EHEC O157 outbreaks. In the present study, we developed a multiplex PCR-based strain-typing method for EHEC O157, which is based on the variability in genomic location of IS629 among EHEC O157 strains. This method is very simple, in that the procedures are completed within 2 h, the analysis can be performed without the need for special equipment or techniques (requiring only conventional PCR and agarose gel electrophoresis systems), the results can easily be transformed into digital data, and the genes for the major virulence markers of EHEC O157 (the stx(1), stx(2), and eae genes) can be detected simultaneously. Using this method, 201 EHEC O157 strains showing different XbaI digestion patterns in pulsed-field gel electrophoresis (PFGE) analysis were classified into 127 types, and outbreak-related strains showed identical or highly similar banding patterns. Although this method is less discriminatory than PFGE, it may be useful as a primary screening tool for EHEC O157 outbreaks.
Rennie, Waverly; Phetsouvanh, Rattanaxay; Lupisan, Socorro; Vanisaveth, Viengsay; Hongvanthong, Bouasy; Phompida, Samlane; Alday, Portia; Fulache, Mila; Lumagui, Richard; Jorgensen, Pernille; Bell, David; Harvey, Steven
2007-01-01
The usefulness of rapid diagnostic tests (RDT) in malaria case management depends on the accuracy of the diagnoses they provide. Despite their apparent simplicity, previous studies indicate that RDT accuracy is highly user-dependent. As malaria RDTs will frequently be used in remote areas with little supervision or support, minimising mistakes is crucial. This paper describes the development of new instructions (job aids) to improve health worker performance, based on observations of common errors made by remote health workers and villagers in preparing and interpreting RDTs, in the Philippines and Laos. Initial preparation using the instructions provided by the manufacturer was poor, but improved significantly with the job aids (e.g. correct use both of the dipstick and cassette increased in the Philippines by 17%). However, mistakes in preparation remained commonplace, especially for dipstick RDTs, as did mistakes in interpretation of results. A short orientation on correct use and interpretation further improved accuracy, from 70% to 80%. The results indicate that apparently simple diagnostic tests can be poorly performed and interpreted, but provision of clear, simple instructions can reduce these errors. Preparation of appropriate instructions and training as well as monitoring of user behaviour are an essential part of rapid test implementation.
Rapid and sensitive detection of mink circovirus by recombinase polymerase amplification.
Ge, Junwei; Shi, Yunjia; Cui, Xingyang; Gu, Shanshan; Zhao, Lili; Chen, Hongyan
2018-06-01
To date, the pathogenic role of mink circovirus (MiCV) remains unclear, and its prevalence and economic importance are unknown. Therefore, a rapid and sensitive molecular diagnosis is necessary for disease management and epidemiological surveillance. However, only PCR methods can identify MiCV infection at present. In this study, we developed a nested PCR and established a novel recombinase polymerase amplification (RPA) assay for MiCV detection. Sensitivity analysis showed that the detection limit of nested PCR and RPA assay was 10 1 copies/reaction, and these methods were more sensitive than conventional PCR, which has a detection limit of 10 5 copies/reaction. The RPA assay had no cross-reactivity with other related viral pathogens, and amplification was completed in less than 20 min with a simple device. Further assessment of clinical samples showed that the two assays were accurate in identifying positive and negative conventional PCR samples. The detection rate of MiCV by the RPA assay in clinical samples was 38.09%, which was 97% consistent with that by the nested PCR. The developed nested PCR is a highly sensitive tool for practical use, and the RPA assay is a simple, sensitive, and potential alternative method for rapid and accurate MiCV diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Cai, Xian-Quan; Yu, Hai-Qiong; Li, Rong; Yue, Qiao-Yun; Liu, Guo-Hua; Bai, Jian-Shan; Deng, Yan; Qiu, De-Yi; Zhu, Xing-Quan
2014-01-01
Clonorchis sinensis and Opisthorchis viverrini are both important fish-borne pathogens, causing serious public health problem in Asia. The present study developed an assay integrating real-time PCR and high resolution melting (HRM) analysis for the specific detection and rapid identification of C. sinensis and O. viverrini. Primers targeting COX1 gene were highly specific for these liver flukes, as evidenced by the negative amplification of closely related trematodes. Assays using genomic DNA extracted from the two flukes yielded specific amplification and their identity was confirmed by sequencing, having the accuracy of 100% in reference to conventional methods. The assay was proved to be highly sensitive with a detection limit below 1 pg of purified genomic DNA, 5 EPG, or 1 metacercaria of C. sinensis. Moreover, C. sinensis and O. viverrini were able to be differentiated by their HRM profiles. The method can reduce labor of microscopic examination and the contamination of agarose electrophoresis. Moreover, it can differentiate these two flukes which are difficult to be distinguished using other methods. The established method provides an alternative tool for rapid, simple, and duplex detection of C. sinensis and O. viverrini.
Vibrio vulnificus typing based on simple sequence repeats: insights into the biotype 3 group.
Broza, Yoav Y; Danin-Poleg, Yael; Lerner, Larisa; Broza, Meir; Kashi, Yechezkel
2007-09-01
Vibrio vulnificus is an opportunistic, highly invasive human pathogen with worldwide distribution. V. vulnificus strains are commonly divided into three biochemical groups (biotypes), most members of which are pathogenic. Simple sequence repeats (SSR) provide a source of high-level genomic polymorphism used in bacterial typing. Here, we describe the use of variations in mutable SSR loci for accurate and rapid genotyping of V. vulnificus. An in silico screen of the genomes of two V. vulnificus strains revealed thousands of SSR tracts. Twelve SSR with core motifs longer than 5 bp in a panel of 32 characterized and 56 other V. vulnificus isolates, including both clinical and environmental isolates from all three biotypes, were tested for polymorphism. All tested SSR were polymorphic, and diversity indices ranged from 0.17 to 0.90, allowing a high degree of discrimination among isolates (27 of 32 characterized isolates). Genetic analysis of the SSR data resulted in the clear distinction of isolates that belong to the highly virulent biotype 3 group. Despite the clonal nature of this new group, SSR analysis demonstrated high-level discriminatory power within the biotype 3 group, as opposed to other molecular methods that failed to differentiate these isolates. Thus, SSR are suitable for rapid typing and classification of V. vulnificus strains by high-throughput capillary electrophoresis methods. SSR (>/=5 bp) by their nature enable the identification of variations occurring on a small scale and, therefore, may provide new insights into the newly emerged biotype 3 group of V. vulnificus and may be used as an efficient tool in epidemiological studies.
Peng, Xiong; Karakalos, Stavros G; Mustain, William E
2018-01-17
Selective electrochemical reduction of CO 2 is one of the most important processes to study because of its promise to convert this greenhouse gas to value-added chemicals at low cost. In this work, a simple anodization treatment was devised that first oxidizes Ag to Ag 2 CO 3 , then uses rapid electrochemical reduction to create preferentially oriented nanoparticles (PONs) of metallic Ag (PON-Ag) with high surface area as well as high activity and very high selectivity for the reduction of CO 2 to CO. The PON-Ag catalyst was dominated by (110) and (100) orientation, which allowed PON-Ag to achieve a CO Faradaic efficiency of 96.7% at an operating potential of -0.69 V vs RHE. This performance is not only significantly higher than that of polycrystalline Ag (60% at -0.87 V vs RHE) but also represents one of the best combinations of activity and selectivity achieved to date - all with a very simple, scalable approach to electrode fabrication.
NASA Astrophysics Data System (ADS)
Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan
2018-04-01
A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.
Wang, Xiao-Fang; Fan, Ji-Cai; Ren, Ren; Jin, Quan; Wang, Jing
2016-06-01
In this study, a simple, rapid, and sensitive method for the determination of nitrite (NO2 (-) ) in food samples by high-performance liquid chromatography with fluorescence detection in acidic conditions had been developed. The derivatization of the nitrite with 2,3-diaminonaphthalene was performed in acidic conditions to yield the highly fluorescent 2,3-naphthotriazole, which was directly analyzed by high-performance liquid chromatography with fluorescence detection without adjusting the solution to alkaline. The analysis column was reversed-phase C8 column. A constant flow rate of 1.0 mL/min was employed using water/acetonitrile as the mobile phase in isocratic mode (70:30, v/v). Fluorescence was monitored with excitation at 375 nm and emission at 415 nm. The standard calibration curves were linear for nitrite in different matrixes in the concentration range of 0-100 μg/L, and the correlation coefficients ranged from 0.9978 to 0.9998. The limits of detection and quantification were in the ranges of 0.012-0.060 and 0.040-0.20 mg/kg, respectively. The recoveries of nitrite from samples spiked at three different concentrations were 74.0-113.2%, and the relative standard deviations of the recovery results (n = 6) were 1.67-10.8%. The proposed method has good repeatability and is very sensitive and simple. It has been successfully used to determine nitrite in foods. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A simple miniature device for wireless stimulation of neural circuits in small behaving animals.
Zhang, Yisi; Langford, Bruce; Kozhevnikov, Alexay
2011-10-30
The use of wireless neural stimulation devices offers significant advantages for neural stimulation experiments in behaving animals. We demonstrate a simple, low-cost and extremely lightweight wireless neural stimulation device which is made from off-the-shelf components. The device has low power consumption and does not require a high-power RF preamplifier. Neural stimulation can be carried out in either a voltage source mode or a current source mode. Using the device, we carry out wireless stimulation in the premotor brain area HVC of a songbird and demonstrate that such stimulation causes rapid perturbations of the acoustic structure of the song. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Liu, Chia-Ying; Han, Yin-Yi; Shih, Po-Han; Lian, Wei-Nan; Wang, Huai-Hsien; Lin, Chi-Hung; Hsueh, Po-Ren; Wang, Juen-Kai; Wang, Yuh-Lin
2016-03-01
Rapid bacterial antibiotic susceptibility test (AST) and minimum inhibitory concentration (MIC) measurement are important to help reduce the widespread misuse of antibiotics and alleviate the growing drug-resistance problem. We discovered that, when a susceptible strain of Staphylococcus aureus or Escherichia coli is exposed to an antibiotic, the intensity of specific biomarkers in its surface-enhanced Raman scattering (SERS) spectra drops evidently in two hours. The discovery has been exploited for rapid AST and MIC determination of methicillin-susceptible S. aureus and wild-type E. coli as well as clinical isolates. The results obtained by this SERS-AST method were consistent with that by the standard incubation-based method, indicating its high potential to supplement or replace existing time-consuming methods and help mitigate the challenge of drug resistance in clinical microbiology.
Caws, Maxine; Tho, Dau Quang; Duy, Phan Minh; Lan, Nguyen Thi Ngoc; Hoa, Dai Viet; Torok, Mili Estee; Chau, Tran Thi Hong; Van Vinh Chau, Nguyen; Chinh, Nguyen Tran; Farrar, Jeremy
2007-01-01
PCR-restriction fragment length poymorphism (PCR-RFLP) is a simple, robust technique for the rapid identification of isoniazid-resistant Mycobacterium tuberculosis. One hundred consecutive isolates from a Vietnamese tuberculosis hospital were tested by MspA1I PCR-RFLP for the detection of isoniazid-resistant katG_315 mutants. The test had a sensitivity of 80% and a specificity of 100% against conventional phenotypic drug susceptibility testing. The positive and negative predictive values were 1 and 0.86, respectively. None of the discrepant isolates had mutant katG_315 codons by sequencing. The test is cheap (less than $1.50 per test), specific, and suitable for the rapid identification of isoniazid resistance in regions with a high prevalence of katG_315 mutants among isoniazid-resistant M. tuberculosis isolates. PMID:17428939
Yagi, Shigeaki; Nishizawa, Manabu; Ando, Itiro; Oguma, Shiro; Sato, Emiko; Imai, Yutaka; Fujiwara, Masako
2016-08-01
A simple, rapid, and selective method for determination of plasma biotin was developed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After single-step protein precipitation with methanol, biotin and stable isotope-labeled biotin as an internal standard (IS) were chromatographed on a pentafluorophenyl stationary-phase column (2.1 × 100 mm, 2.7 μm) under isocratic conditions using 10 mm ammonium formate-acetonitrile (93:7, v/v) at a flow rate of 0.6 mL/min. The total chromatographic runtime was 5 min for each injection. Detection was performed in a positive electrospray ionization mode by monitoring selected ion transitions at m/z 245.1/227.0 and 249.1/231.0 for biotin and the IS, respectively. The calibration curve was linear in the range of 0.05-2 ng/mL using 300 μL of plasma. The intra- and inter-day precisions were all <7.1%. The accuracy varied from -0.7 to 8.2%. The developed UHPLC-MS/MS method was successfully applied to determine plasma biotin concentrations in hemodialysis patients. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Rapid Microfluidic Mixers Utilizing Dispersion Effect and Interactively Time-Pulsed Injection
NASA Astrophysics Data System (ADS)
Leong, Jik-Chang; Tsai, Chien-Hsiung; Chang, Chin-Lung; Lin, Chiu-Feng; Fu, Lung-Ming
2007-08-01
In this paper, we present a novel active microfluidic mixer utilizing a dispersion effect in an expansion chamber and applying interactively time-pulsed driving voltages to the respective inlet fluid flows to induce electroosmotic flow velocity variations for developing a rapid mixing effect in a microchannel. Without using any additional equipment to induce flow perturbations, only a single high-voltage power source is required for simultaneously driving and mixing sample fluids, which results in a simple and low-cost system for mixing. The effects of the applied main electrical field, interactive frequency, and expansion ratio on the mixing performance are thoroughly examined experimentally and numerically. The mixing ratio can be as high as 95% within a mixing length of 3000 μm downstream from the secondary T-form when a driving electric field strength of 250 V/cm, a periodic switching frequency of 5 Hz, and the expansion ratio M=1:10 are applied. In addition, the optimization of the driving electric field, switching frequency, expansion ratio, expansion entry length, and expansion chamber length for achieving a maximum mixing ratio is also discussed in this study. The novel method proposed in this study can be used for solving the mixing problem in the field of micro-total-analysis systems in a simple manner.
NASA Astrophysics Data System (ADS)
Tan, Hui-Gee; Duh, Jenq-Gong
2016-12-01
A vast quantity of waste sludge is generated during the silicon wafers slicing process in semiconductor and photovoltaic industries. Turning the waste powder into high-value products is of strategic importance for industrial processes. The purified Si microparticles (Si-MP) are recycled by a simple and fast procedure, Rapid Thermal Process (RTP). A prominent anodic material of Si-MP/Carbon composite with porous structure is obtained via in-spaced carbonization of water-soluble binder sodium carboxymethyl cellulose during RTP. This strategy provides buffer space, which is constructed by carbon porous continuous conductive framework throughout the entire electrode, to resist local stress and intense volume variation. In addition, a sufficiently electrochemically stable solid-electrolyte interphase layer is accomplished with the coating of SiOx film and amorphous carbon on the surface of Si-MP. Under these circumstances, the enhanced electrodes achieve a first cycle efficiency of approximately 80% and a reversible charge capacity of 800 mAhg-1 over 100 cycles at 0.5 Ag-1 with good retention. Through a green and simple procedure, a remarkable Si-MP embedded carbon-matrix with porous structure is established to achieve commercially high performance Si-MP/C composite anodes and also to resolve the issues of waste disposal.
Verkoelen, C F; Romijn, J C; Schroeder, F H; van Schalkwijk, W P; Splinter, T A
1988-04-08
A rapid and simple method, originally described by Redmond and Tseng [J. Chromatogr., 170 (1979) 479] was applied to the analysis of di- and polyamines in cultured human tumour cells and human tumour xenografts. Optimization of the procedures and evaluation of the characteristic features of the assay are described. The (modified) procedure employs precolumn derivatization with benzoyl chloride, extraction of the derivatives by chloroform, separation by reversed-phase high-performance liquid chromatography under isocratic conditions and detection by ultraviolet absorbance measurement at 229 nm. The complete analysis was accomplished within 10 min per sample. The detection limit was ca. 1 pmol. The intra- and inter-assay coefficients of variation were 2.5-4.4% and 3.4-13.1%, respectively. The presence of well known inhibitors of polyamine biosynthesis, such as DL-alpha-difluoromethylornithine and methylglyoxal bis(guanylhydrazone), did not interfere with the assay, and disturbance by cyclohexylamine could be avoided by changing the polarity of the mobile phase. The method proved to be very suitable because it is rapid, simple, requires a minimum of sample pretreatment, and still provides sufficient sensitivity to quantitate polyamines in relatively small amounts of cells (10(5) cells) or tumour tissues (less than 1 mg), even after treatment with inhibitors of polyamine biosynthesis.
Mashooq, Mohmad; Kumar, Deepak; Niranjan, Ankush Kiran; Agarwal, Rajesh Kumar; Rathore, Rajesh
2016-07-01
A one step, single tube, accelerated probe based real time loop mediated isothermal amplification (RT LAMP) assay was developed for detecting the invasion gene (InvA) of Salmonella. The probe based RT LAMP is a novel method of gene amplification that amplifies nucleic acid with high specificity and rapidity under isothermal conditions with a set of six primers. The whole procedure is very simple and rapid, and amplification can be obtained in 20min. Detection of gene amplification was accomplished by amplification curve, turbidity and addition of DNA binding dye at the end of the reaction results in colour difference and can be visualized under normal day light and in UV. The sensitivity of developed assay was found 10 fold higher than taqman based qPCR. The specificity of the RT LAMP assay was validated by the absence of any cross reaction with other members of enterobacteriaceae family and other gram negative bacteria. These results indicate that the probe based RT LAMP assay is extremely rapid, cost effective, highly specific and sensitivity and has potential usefulness for rapid Salmonella surveillance. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.
Ohshima, Chihiro; Takahashi, Hajime; Phraephaisarn, Chirapiphat; Vesaratchavest, Mongkol; Keeratipibul, Suwimon; Kuda, Takashi; Kimura, Bon
2014-01-01
Listeria monocytogenes is the causative bacteria of listeriosis, which has a higher mortality rate than that of other causes of food poisoning. Listeria spp., of which L. monocytogenes is a member, have been isolated from food and manufacturing environments. Several methods have been published for identifying Listeria spp.; however, many of the methods cannot identify newly categorized Listeria spp. Additionally, they are often not suitable for the food industry, owing to their complexity, cost, or time consumption. Recently, high-resolution melting analysis (HRMA), which exploits DNA-sequence differences, has received attention as a simple and quick genomic typing method. In the present study, a new method for the simple, rapid, and low-cost identification of Listeria spp. has been presented using the genes rarA and ldh as targets for HRMA. DNA sequences of 9 Listeria species were first compared, and polymorphisms were identified for each species for primer design. Species specificity of each HRM curve pattern was estimated using type strains of all the species. Among the 9 species, 7 were identified by HRMA using rarA gene, including 3 new species. The remaining 2 species were identified by HRMA of ldh gene. The newly developed HRMA method was then used to assess Listeria isolates from the food industry, and the method efficiency was compared to that of identification by 16S rDNA sequence analysis. The 2 methods were in coherence for 92.6% of the samples, demonstrating the high accuracy of HRMA. The time required for identifying Listeria spp. was substantially low, and the process was considerably simplified, providing a useful and precise method for processing multiple samples per day. Our newly developed method for identifying Listeria spp. is highly valuable; its use is not limited to the food industry, and it can be used for the isolates from the natural environment.
Ohshima, Chihiro; Takahashi, Hajime; Phraephaisarn, Chirapiphat; Vesaratchavest, Mongkol; Keeratipibul, Suwimon; Kuda, Takashi; Kimura, Bon
2014-01-01
Listeria monocytogenes is the causative bacteria of listeriosis, which has a higher mortality rate than that of other causes of food poisoning. Listeria spp., of which L. monocytogenes is a member, have been isolated from food and manufacturing environments. Several methods have been published for identifying Listeria spp.; however, many of the methods cannot identify newly categorized Listeria spp. Additionally, they are often not suitable for the food industry, owing to their complexity, cost, or time consumption. Recently, high-resolution melting analysis (HRMA), which exploits DNA-sequence differences, has received attention as a simple and quick genomic typing method. In the present study, a new method for the simple, rapid, and low-cost identification of Listeria spp. has been presented using the genes rarA and ldh as targets for HRMA. DNA sequences of 9 Listeria species were first compared, and polymorphisms were identified for each species for primer design. Species specificity of each HRM curve pattern was estimated using type strains of all the species. Among the 9 species, 7 were identified by HRMA using rarA gene, including 3 new species. The remaining 2 species were identified by HRMA of ldh gene. The newly developed HRMA method was then used to assess Listeria isolates from the food industry, and the method efficiency was compared to that of identification by 16S rDNA sequence analysis. The 2 methods were in coherence for 92.6% of the samples, demonstrating the high accuracy of HRMA. The time required for identifying Listeria spp. was substantially low, and the process was considerably simplified, providing a useful and precise method for processing multiple samples per day. Our newly developed method for identifying Listeria spp. is highly valuable; its use is not limited to the food industry, and it can be used for the isolates from the natural environment. PMID:24918440
Song, Chihong; Lee, Ju Huck; Jun, Sangmi; Chung, Jeong Min; Hyun, Jaekyung; Jung, Hyun Suk
2016-05-01
The preparation of biological specimens using cryofixation techniques ensures excellent visibility of intracellular structures and preserves the antigenic sites of subcellular molecules. Hence, cryofixation is an effective method of preparing samples for analyses using antibodies conjugated to gold nanoparticles that are designed to detect the localization of specific target molecules within cells. However, cryofixation cannot be utilized easily because it requires expensive equipment and skilled technologists, resulting in a high level of expense for researchers. Here, we describe a simple technical approach to cryofixation that uses metal contact quick freezing followed by a modified freeze substitution technique and immuno-gold labeling electron microscopy. Micrograph images of cells prepared using this modified cryofixation method demonstrated its superiority over chemical fixation for high contrast visualization of the morphologies of cellular components and preservation of antigenicity for immuno-gold labeling. This report provides valuable technical information related to the advancement of metal contact quick freezing techniques, which can be used to visualize biomedical events of interest in an easy, simple, and rapid manner.
Simple detection of residual enrofloxacin in meat products using microparticles and biochips.
Ha, Mi-Sun; Chung, Myung-Sub; Bae, Dong-Ho
2016-05-01
A simple and sensitive method for detecting enrofloxacin, a major veterinary fluoroquinolone, was developed. Monoclonal antibody specific for enrofloxacin was immobilised on a chip and fluorescent dye-labelled microparticles were covalently bound to the enrofloxacin molecules. Enrofloxacin in solution competes with the microparticle-immobilised enrofloxacin (enroMPs) to bind to the antibody on the chip. The presence of enrofloxacin was verified by detecting the fluorescence of enrofloxacin-bound microparticles. Under optimum conditions, a high dynamic range was achieved at enrofloxacin concentrations ranging from 1 to 1000 μg kg(-1). The limits of detection and quantification for standard solutions were 5 and 20 μg kg(-1) respectively, which are markedly lower than the maximum residue limit. Using simple extraction methods, recoveries from fortified beef, pork and chicken samples were 43.4-62.3%. This novel method also enabled approximate quantification of enrofloxacin concentration: the enroMP signal intensity decreased with increasing enrofloxacin concentration. Because of its sensitivity, specificity, simplicity and rapidity, the method described herein will facilitate the detection and approximate quantification of enrofloxacin residues in foods in a high-throughput manner.
Rapid detection of cancer related DNA nanoparticulate biomarkers and nanoparticles in whole blood
NASA Astrophysics Data System (ADS)
Heller, Michael J.; Krishnan, Raj; Sonnenberg, Avery
2010-08-01
The ability to rapidly detect cell free circulating (cfc) DNA, cfc-RNA, exosomes and other nanoparticulate disease biomarkers as well as drug delivery nanoparticles directly in blood is a major challenge for nanomedicine. We now show that microarray and new high voltage dielectrophoretic (DEP) devices can be used to rapidly isolate and detect cfc-DNA nanoparticulates and nanoparticles directly from whole blood and other high conductance samples (plasma, serum, urine, etc.). At DEP frequencies of 5kHz-10kHz both fluorescent-stained high molecular weight (hmw) DNA, cfc-DNA and fluorescent nanoparticles separate from the blood and become highly concentrated at specific DEP highfield regions over the microelectrodes, while blood cells move to the DEP low field-regions. The blood cells can then be removed by a simple fluidic wash while the DNA and nanoparticles remain highly concentrated. The hmw-DNA could be detected at a level of <260ng/ml and the nanoparticles at <9.5 x 109 particles/ml, detection levels that are well within the range for viable clinical diagnostics and drug nanoparticle monitoring. Disease specific cfc-DNA materials could also be detected directly in blood from patients with Chronic Lymphocytic Leukemia (CLL) and confirmed by PCR genotyping analysis.
Mueller, D; Kulkarni, Harshad; Baum, Richard P; Odparlik, Andreas
2017-04-01
99m Tc-labeled MAA is commonly used for single photon emission computed tomography SPECT. In contrast, positron emission tomography/CT (PET/CT) delivers images with significantly higher resolution. The generator produced radionuclide 68 Ga is widely used for PET/CT imaging agents and 68 Ga-labeled MAA represents an attractive alternative to 99m Tc-labeled MAA. We report a simple and rapid NaCl based labeling procedure for the labeling of MAA with 68 Ga using a commercially available MAA labeling kit for 99m Tc. The procedure delivers 68 Ga-labeled MAA with a high specific activity and a high labeling efficiency (>99%). The synthesis does not require a final step of separation or the use of organic solvents. Copyright © 2017 Elsevier Ltd. All rights reserved.
Highly selective colorimetric bacteria sensing based on protein-capped nanoparticles.
Qiu, Suyan; Lin, Zhenyu; Zhou, Yaomin; Wang, Donggen; Yuan, Lijuan; Wei, Yihua; Dai, Tingcan; Luo, Linguang; Chen, Guonan
2015-02-21
A rapid and cost-effective colorimetric sensor has been developed for the detection of bacteria (Bacillus subtilis was selected as an example). The sensor was designed to rely on lysozyme-capped AuNPs with the advantages of effective amplification and high specificity. In the sensing system, lysozyme was able to bind strongly to Bacillus subtilis, which effectively induced a color change of the solution from light purple to purplish red. The lowest concentration of Bacillus subtilis detectable by the naked eye was 4.5 × 10(3) colony-forming units (CFU) mL(-1). Similar results were discernable from UV-Vis absorption measurements. A good specificity was observed through a statistical analysis method using the SPSS software (version 17.0). This simple colorimetric sensor may therefore be a rapid and specific method for a bacterial detection assay in complex samples.
OpenCluster: A Flexible Distributed Computing Framework for Astronomical Data Processing
NASA Astrophysics Data System (ADS)
Wei, Shoulin; Wang, Feng; Deng, Hui; Liu, Cuiyin; Dai, Wei; Liang, Bo; Mei, Ying; Shi, Congming; Liu, Yingbo; Wu, Jingping
2017-02-01
The volume of data generated by modern astronomical telescopes is extremely large and rapidly growing. However, current high-performance data processing architectures/frameworks are not well suited for astronomers because of their limitations and programming difficulties. In this paper, we therefore present OpenCluster, an open-source distributed computing framework to support rapidly developing high-performance processing pipelines of astronomical big data. We first detail the OpenCluster design principles and implementations and present the APIs facilitated by the framework. We then demonstrate a case in which OpenCluster is used to resolve complex data processing problems for developing a pipeline for the Mingantu Ultrawide Spectral Radioheliograph. Finally, we present our OpenCluster performance evaluation. Overall, OpenCluster provides not only high fault tolerance and simple programming interfaces, but also a flexible means of scaling up the number of interacting entities. OpenCluster thereby provides an easily integrated distributed computing framework for quickly developing a high-performance data processing system of astronomical telescopes and for significantly reducing software development expenses.
A simple and rapid latex fixation test for measuring immunoglobulins produced in cell cultures.
Kasahara, T; Harada, H; Enomoto, H; Itoh, Y; Kawai, T; Shioiri-Nakano, K
1981-01-01
A rapid and simple latex fixation test (LFT), which quantifies immunoglobulin (Ig) released into culture supernatants is described. Latex particles are coated with rabbit anti-human IgG, IgA or IgM antibodies. With this LFT technique the concentration of Ig is determined within a few minutes. The LFT is as sensitive and quantitative as double-antibody radioimmunoassay and is capable of detecting 35, 68 and 225 ng/ml of IgG, IgA and IgM, respectively.
Cai, Shuang-Hu; Wang, Bei; Lu, Yi-Shan; Jian, Ji-Chang; Wu, Zao-He
2012-04-01
Streptococcus iniae is a major pathogen that causes sever economic losses in tilapia aquaculture. A set of four specific primers was designed by targeting lctO gene. With Bst DNA polymerase, the target DNA can be clearly amplified for 60 min at 64 °C in a simple water bath. The sensitivity of the LAMP assay for the detection of S. iniae is about 12.4 cells per reaction in both of pure cultures and added fish tissues cultures. LAMP products could be judged with agar gel or naked eye after addition of SYBR Green I. There were no cross-reactions with other bacterial strains indicating high specificity of the LAMP. The LAMP method was also applied to detect S. iniae-infected tilapia tissues effectively. The LAMP assay reported here indicates the potential usefulness of the technique as a valuable simple, rapid alternative procedure for the detection of S. iniae during streptococcicosis monitoring of cultured fish. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Badawy, Abdulla A-B; Morgan, Christopher J
2010-01-01
A simple, rapid isocratic liquid chromatographic procedure with ultraviolet and fluorimetric detection is described for the separation and quantification of L-tryptophan (Trp) and six of its kynurenine metabolites (kynurenine, 3-hydroxykynurenine, and 3-hydroxyanthranilic, kynurenic, xanthurenic and anthranilic acids). Using the Perkin Elmer LC 200 system, a reverse phase Synergi 4 μ fusion-RP80 A column (250 × 4.6 mm) (Phenomenex), and a mobile phase of 10 mM sodium dihydrogen phosphate: methanol (73:27, by vol) at pH 2.8 and a flow rate of 1.0–1.2 ml/min at 37 °C, a run took ∼13 min. The run took <7 min at 40 °C and a 1.4 ml/min flow rate. Limits of detection of all 7 analytes were 5–72 nM and their recoveries from human plasma and rat serum and liver varied between 62% and 111%. This simple method is suitable for high throughput work and can be further developed to include quinolinic acid and other Trp metabolites. PMID:22084598
Development of a rapid, simple assay of plasma total carotenoids
2012-01-01
Background Plasma total carotenoids can be used as an indicator of risk of chronic disease. Laboratory analysis of individual carotenoids by high performance liquid chromatography (HPLC) is time consuming, expensive, and not amenable to use beyond a research laboratory. The aim of this research is to establish a rapid, simple, and inexpensive spectrophotometric assay of plasma total carotenoids that has a very strong correlation with HPLC carotenoid profile analysis. Results Plasma total carotenoids from 29 volunteers ranged in concentration from 1.2 to 7.4 μM, as analyzed by HPLC. A linear correlation was found between the absorbance at 448 nm of an alcohol / heptane extract of the plasma and plasma total carotenoids analyzed by HPLC, with a Pearson correlation coefficient of 0.989. The average coefficient of variation for the spectrophotometric assay was 6.5% for the plasma samples. The limit of detection was about 0.3 μM and was linear up to about 34 μM without dilution. Correlations between the integrals of the absorption spectra in the range of carotenoid absorption and total plasma carotenoid concentration gave similar results to the absorbance correlation. Spectrophotometric assay results also agreed with the calculated expected absorbance based on published extinction coefficients for the individual carotenoids, with a Pearson correlation coefficient of 0.988. Conclusion The spectrophotometric assay of total carotenoids strongly correlated with HPLC analysis of carotenoids of the same plasma samples and expected absorbance values based on extinction coefficients. This rapid, simple, inexpensive assay, when coupled with the carotenoid health index, may be useful for nutrition intervention studies, population cohort studies, and public health interventions. PMID:23006902
Adamowicz, Piotr; Tokarczyk, Bogdan
2016-07-01
In recent years, many new psychoactive substances (NPS) from several drug classes have appeared on the drug market. These substances, also known as 'legal highs', belong to different chemical classes. Despite the increasing number of NPS, there are few comprehensive screening methods for their detection in biological specimens. In this context, the purpose of this study was to develop a fast and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening procedure for NPS in blood. The elaborated method allows the simultaneous screening of 143 compounds from different groups (number of compounds): cathinones (36), phenethylamines (26), tryptamines (18), piperazines (9), piperidines (2), synthetic cannabinoids (34), arylalkylamines (7), arylcyclohexylamines (3), aminoindanes (2), and other drugs (6). Blood samples (0.2 mL) were precipitated with acetonitrile (0.6 mL). The separation was achieved with gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 14 min. Detection of all compounds was based on multiple reaction monitoring (MRM) transitions. The total number of transitions monitored in dynamic mode was 432. The whole procedure was rapid and simple. The limits of detection (LODs) estimated for 104 compounds were in the range 0.01-3.09 ng/mL. The extraction recoveries determined for 32 compounds were from 1.8 to 133%. The procedure was successfully applied to the analysis of forensic blood samples in routine casework. The developed method should have wide applicability for rapid screening of new drugs of abuse in forensic or clinical samples. The procedure can be easily expanded for more substances. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
The Invention Convention: Mind Meets Simple Machines.
ERIC Educational Resources Information Center
Hadi-Tabassum, Samina
1997-01-01
Describes an Earth Day celebration where students had to design an invention made of simple machines that could crush an empty aluminum can through 10 rapid mechanical movements using materials foraged from the students' homes. (JRH)
The Rapid Gamma-ray Burst Response Campaign with ROTSE
NASA Astrophysics Data System (ADS)
Balsano, R.; Bloch, J.; Casperson, D.; Fletcher, S.; Gisler, G.; Hills, J.; Priedhorsky, W.; Szymanski, J.; Wren, J.; Akerlof, C.; Kehoe, R.; McKay, T.; Pawl, A.; Marshall, S.; Lee, B.; Barthelmy, S.; Butterworth, P.; Cline, T.
2000-04-01
The main goal of the Robotic Optical Transient Search Experiment (ROTSE) is to detect optical emission from Gamma-ray Bursts (GRBs) during and immediately following GRBs. The instruments comprising ROTSE consist of wide-field optics on rapidly slewing mounts optimized for quick response to GRBs localized to several degree regions. Thus far, only one prompt optical counterpart to a GRB has been discovered although simple scaling arguments suggest more should be easily detected. This talk will cover ROTSE responses to GRBs detected by the Burst and Transient Source Experiment and the soon-to-be-launched High Energy Transient Experiment. The expansion of ROTSE to a global network of identical telescopes will also be briefly discussed.
Trangoni, Marcos D; Gioffré, Andrea K; Cravero, Silvio L
2017-01-01
LAMP (loop-mediated isothermal amplification) is an isothermal nucleic acid amplification technique that is characterized by its efficiency, rapidity, high yield of final product, robustness, sensitivity, and specificity, with the blueprint that it can be implemented in laboratories of low technological complexity. Despite the conceptual complexity underlying the mechanistic basis for the nucleic acid amplification, the technique is simple to use and the amplification and detection can be carried out in just one step. In this chapter, we present a protocol based on LAMP for the rapid identification of isolates of Brucella spp. and Mycobacterium avium subsp. paratuberculosis, two major bacterial pathogens in veterinary medicine.
Wang, Shinn-Fwu
2009-01-01
A small-displacement sensor based on total-internal reflection theory and surface plasmon resonance technology is proposed for use in heterodyne interferometry. A small displacement can be obtained simply by measuring the variation in phase difference between s- and p-polarization states with the small-displacement sensor. The theoretical displacement resolution of the small-displacement sensor can reach 0.45 nm. The sensor has some additional advantages, e.g., a simple optical setup, high resolution, high sensitivity and rapid measurement. Its feasibility is also demonstrated.
Commercialization of the Stone and Webster/Conoco SCB technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, R.C.; Johnson, W.B.; Ratliff, B.D.
1982-06-01
Stone and Webster have developed a second generation recirculating fluidized bed boiler system, named Solids Circulation Boiler (SCB). The heart of the system is the recirculating fluidized bed, which is schematized, and explained. In November 1981 Conoco announced plans to construct an SCB at Lake Charles LA. Preliminary plot plan and elevation drawings are provided. The advantages of SCB are its rapid and controlled turn on and turn down capability, high carbon efficiency, simple coal and limestone feed system, high sulphur capture, compact design, and low NOx emission.
270V Battery Using COTS NiCd Cells For Manned Spacecraft
NASA Technical Reports Server (NTRS)
Darcy, Eric; Davies,Frank; Hummer, Leigh; Strangways, Brad
2002-01-01
A high power (>35 kW at 215V), low capacity (5.2 Ah), and compact (45L) NiCd battery was developed for the X-38 Crew Return Vehicle (CRV), which is an experimental version of the lifeboat for the International Space Station (ISS). A simple design and innovative approach using a commercial-off-the-shelf (COTS) NiCd cell design enabled the design, qualification, and production of 4 flight units of this highly reliable and safe spacecraft battery to be achieved rapidly (2 years) and cheaply ($13M).
Lee, Ji-Hyeok; Kim, Hyung-Ho; Ko, Ju-Young; Jang, Jun-Ho; Kim, Gwang-Hoon; Lee, Jung-Suck; Nah, Jae-Woon; Jeon, You-Jin
2016-11-20
This study describes a simple preparation of functional polysaccharides from Pyropia yezoensis using a microwave-assistant rapid enzyme digest system (MAREDS) with various carbohydrases, and evaluates their antioxidative effects. Polysaccharide hydrolysates were prepared using MAREDS under different hydrolytic conditions of the carbohydrases and microwave powers. Polysaccharides less than 10kDa (Low molecular weight polysaccharides, LMWP, ≤10kDa) were efficiently obtained using an ultrafiltration (molecular weight cut-off of 10kDa). MAREDS increases AMG activation via an increased degree of hydrolysis; the best AMG hydrolysate was prepared using a 10:1 ratio of substrate to enzyme for 2h in MAREDS with 400W. LMWP consisted of galactose (27.3%), glucose (64.5%), and mannose (8.3%) from the AMG hydrolysate had stronger antioxidant effects than the high molecular weight polysaccharides (>10kDa). We rapidly prepared functional LMWPs by using MAREDS with carbohydrases, and suggest that LMWP might be potentially a valuable algal polysaccharide antioxidant. Copyright © 2016 Elsevier Ltd. All rights reserved.
Saha, Arindam; Jana, Nikhil R
2015-01-14
Although microfluidic approach is widely used in various point of care diagnostics, its implementation in surface enhanced Raman spectroscopy (SERS)-based detection is challenging. This is because SERS signal depends on plasmonic nanoparticle aggregation induced generation of stable electromagnetic hot spots and in currently available microfluidic platform this condition is difficult to adapt. Here we show that SERS can be adapted using simple paper based microfluidic system where both the plasmonic nanomaterials and analyte are used in mobile phase. This approach allows analyte induced controlled particle aggregation and electromagnetic hot spot generation inside the microfluidic channel with the resultant SERS signal, which is highly reproducible and sensitive. This approach has been used for reproducible detection of protein in the pico to femtomolar concentration. Presented approach is simple, rapid, and cost-effective, and requires low sample volume. Method can be extended for SERS-based detection of other biomolecules.
Steinhauser, Georg; Steinhauser, Veronika
2016-11-01
Many species of mushrooms are known accumulators of radioactive cesium ( 137 Cs and 134 Cs). Even years and decades after major nuclear accidents, especially those at Chernobyl and Fukushima, mushrooms exhibit high concentrations of these radionuclides. We investigated a simple method for reducing the activity of radiocesium in wild mushrooms (chanterelles, Cantharellus cibarius ; and boleti, Boletus edulis ) during cooking. The juice generated while cooking mushrooms contains a relatively high fraction of the total cesium. The amount of juice can be increased by washing the mushrooms with water prior to cooking. By removing the juice, up to 29% of the radiocesium can be easily removed from chanterelles. Because boleti have a lower affinity for cesium, activity levels were lower in boleti than in chanterelles. The fraction of radiocesium in the juice was lower in boleti than in chanterelles.
[Management of Acute Type A Dissection Complicated with Acute Mesenteric Ischemia].
Abe, Tomonobu; Usui, Akihiko
2017-07-01
Acute mesenteric ischemia as malperfusion syndrome associated with acute aortic dissection is a difficult situation. The incidence is approximately 3~4% in acute type A dissection. Traditionally, most of these patients underwent immediate simple central aortic repair expecting that mesenteric artery obstruction and intestinal ischemia would be resolved by simple central aortic repair. However, short term mortality has been reported very high in this strategy. With the aid of rapidly progressing imaging techniques and newer endovascular repair techniques, results seem to be improving in recent years. Newer management strategy include aggressive and patient specific revascularization to the mesenteric arteries, delayed central aortic repair, and meticulous intensive care. Diagnosis and management of this condition require high level of expertise. Cardiac surgeons, vascular surgeons, interventional radiologists, gastroenterologists, general surgeons, anesthesiologists, intensivists must corporate to save these patients' lives. Since this is a relatively rare condition, scientific evidence is insufficient to make robust recommendations. Further studies are warranted.
Enantioselective cyclizations and cyclization cascades of samarium ketyl radicals
NASA Astrophysics Data System (ADS)
Kern, Nicolas; Plesniak, Mateusz P.; McDouall, Joseph J. W.; Procter, David J.
2017-12-01
The rapid generation of molecular complexity from simple starting materials is a key challenge in synthesis. Enantioselective radical cyclization cascades have the potential to deliver complex, densely packed, polycyclic architectures, with control of three-dimensional shape, in one step. Unfortunately, carrying out reactions with radicals in an enantiocontrolled fashion remains challenging due to their high reactivity. This is particularly the case for reactions of radicals generated using the classical reagent, SmI2. Here, we demonstrate that enantioselective SmI2-mediated radical cyclizations and cascades that exploit a simple, recyclable chiral ligand can convert symmetrical ketoesters to complex carbocyclic products bearing multiple stereocentres with high enantio- and diastereocontrol. A computational study has been used to probe the origin of the enantioselectivity. Our studies suggest that many processes that rely on SmI2 can be rendered enantioselective by the design of suitable ligands.
Alnasser, Yossef; Ferradas, Cusi; Clark, Taryn; Calderon, Maritza; Gurbillon, Alejandro; Gamboa, Dionicia; McKakpo, Uri S.; Quakyi, Isabella A.; Bosompem, Kwabena M.; Sullivan, David J.; Vinetz, Joseph M.; Gilman, Robert H.
2016-01-01
Plasmodium vivax is the most prevalent cause of human malaria in the world and can lead to severe disease with high potential for relapse. Its genetic and geographic diversities make it challenging to control. P. vivax is understudied and to achieve control of malaria in endemic areas, a rapid, accurate, and simple diagnostic tool is necessary. In this pilot study, we found that a colorimetric system using AuNPs and MSP10 DNA detection in urine can provide fast, easy, and inexpensive identification of P. vivax. The test exhibited promising sensitivity (84%), high specificity (97%), and only mild cross-reactivity with P. falciparum (21%). It is simple to use, with a visible color change that negates the need for a spectrometer, making it suitable for use in austere conditions. Using urine eliminates the need for finger-prick, increasing both the safety profile and patient acceptance of this model. PMID:27706158
Development of a simple algorithm to guide the effective management of traumatic cardiac arrest.
Lockey, David J; Lyon, Richard M; Davies, Gareth E
2013-06-01
Major trauma is the leading worldwide cause of death in young adults. The mortality from traumatic cardiac arrest remains high but survival with good neurological outcome from cardiopulmonary arrest following major trauma has been regularly reported. Rapid, effective intervention is required to address potential reversible causes of traumatic cardiac arrest if the victim is to survive. Current ILCOR guidelines do not contain a standard algorithm for management of traumatic cardiac arrest. We present a simple algorithm to manage the major trauma patient in actual or imminent cardiac arrest. We reviewed the published English language literature on traumatic cardiac arrest and major trauma management. A treatment algorithm was developed based on this and the experience of treatment of more than a thousand traumatic cardiac arrests by a physician - paramedic pre-hospital trauma service. The algorithm addresses the need treat potential reversible causes of traumatic cardiac arrest. This includes immediate resuscitative thoracotomy in cases of penetrating chest trauma, airway management, optimising oxygenation, correction of hypovolaemia and chest decompression to exclude tension pneumothorax. The requirement to rapidly address a number of potentially reversible pathologies in a short time period lends the management of traumatic cardiac arrest to a simple treatment algorithm. A standardised approach may prevent delay in diagnosis and treatment and improve current poor survival rates. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Wang, Ting; Zhang, Kun-He; Hu, Piao-Ping; Huang, Zeng-Yong; Zhang, Pan; Wan, Qin-Si; Huang, De-Qiang; Lv, Nong-Hua
2016-09-27
The diagnosis of early, small and alpha-fetoprotein (AFP)-negative primary hepatic carcinomas (PHCs) remains a significant challenge. We developed a simple and robust approach to noninvasively detect these PHCs. A rapid, high-throughput and single-tube method was firstly developed to measure serum autofluorescence and cell-free DNA (cfDNA)-related fluorescence using a real-time PCR system, and both types of serum fluorescence were measured and routine laboratory data were collected in 1229 subjects, including 353 PHC patients, 331 liver cirrhosis (LC) patients, 213 chronic hepatitis (CH) patients and 332 normal controls (NC). The results showed that fluorescence indicators of PHC differed from those of NC, CH and LC to various extents, and all of them were not associated with age, gender, or AFP level. The logistic regression models established with the fluorescence indicators alone and combined with AFP, hepatic function tests and blood cell analyses were valuable for distinguishing early, small, AFP-negative and all PHC from LC, CH, NC and all non-PHC, with areas under the receiver operating characteristic curves 0.857-0.993 and diagnostic accuracies 80.2-97.7%. Conclusively, serum autofluorescence and cfDNA-related fluorescence are able to be rapidly and simultaneously measured by our simple method and valuable for diagnosing early, small and AFP-negative PHCs, especially integrating with AFP and conventional blood tests.
Ghanim, Murad; Brumin, Marina; Popovski, Smadar
2009-08-01
A simple, rapid, inexpensive method for the localization of virus transcripts in plant and insect vector tissues is reported here. The method based on fluorescent in situ hybridization using short DNA oligonucleotides complementary to an RNA segment representing a virus transcript in the infected plant or insect vector. The DNA probe harbors a fluorescent molecule at its 5' or 3' ends. The protocol: simple fixation, hybridization, minimal washing and confocal microscopy, provides a highly specific signal. The reliability of the protocol was tested by localizing two phloem-limited plant virus transcripts in infected plants and insect tissues: Tomato yellow leaf curl virus (TYLCV) (Begomovirus: Geminiviridae), exclusively transmitted by the whitefly Bemisia tabaci (Gennadius) in a circulative non-propagative manner, and Potato leafroll virus (Polerovirus: Luteoviridae), similarly transmitted by the aphid Myzus persicae (Sulzer). Transcripts for both viruses were localized specifically to the phloem sieve elements of infected plants, while negative controls showed no signal. TYLCV transcripts were also localized to the digestive tract of B. tabaci, confirming TYLCV route of transmission. Compared to previous methods for localizing virus transcripts in plant and insect tissues that include complex steps for in-vitro probe preparation or antibody raising, tissue fixation, block preparation, sectioning and hybridization, the method described below provides very reliable, convincing, background-free results with much less time, effort and cost.
NASA Astrophysics Data System (ADS)
Guo, Pengfei; Shen, Xia; Zhang, Baolong; Sun, Haibin; Zou, Zhijun; Yang, Wenchao; Gong, Ke; Luo, Yongsong
2018-05-01
A simple two-step CVD method is developed to realize the growth of high-quality tin-catalyzed CdSSe alloy nanowires. Microstructural characterizations demonstrate that these wires are high-quality crystalline nanostructures. Local photoluminescence investigation of these nanostructures shows a typical band edge emission at 656 nm with a full-width at half-maximum of 22.3 nm. Optical waveguide measurement along an individual nanowire indicates that the output signal of the guided light has a rapid linear decrease accompanied with maximum red-shift about 109 meV after the transmission of 102 μm. This obvious red-shift is caused by the intensive band-tail absorption during the optical transmission process. Moreover, optically pumped nanolasers are successfully realized at room temperature based on these unique wires, further demonstrating the achievement of stimulated emission from spontaneous emission, promoted by the pump power intensity. This work may find a simple route to the manufacture of superior nanowires for applications in waveguide and integrated photonic devices.
Vázquez-Iglesias, Lorena; Estefanell-Ucha, Borja; Barcia-Castro, Leticia; Páez de la Cadena, María; Álvarez-Chaver, Paula; Ayude-Vázquez, Daniel; Rodríguez-Berrocal, Francisco Javier
2017-01-01
Clostridium septicum produces a number of diseases in human and farm animals which, in most of the cases, are fatal without clinical intervention. Alpha toxin is an important agent and the unique lethal virulent factor produced by Clostridium septicum. This toxin is haemolytic, highly lethal and necrotizing activities but is being used as an antigen to develop animal vaccines. The aim of this study was to isolate the alpha toxin of Clostridium septicum and produce highly specific antibodies against it. In this work, we have developed a simple and efficient method for alpha toxin purification, based on electroelution that can be used as a time-saving method for purifying proteins. This technique avoids contamination by other proteins that could appear during other protein purification techniques such chromatography. The highly purified toxin was used to produce polyclonal antibodies. The specificity of the antibodies was tested by western blot and these antibodies can be applied to the quantitative determination of alpha toxin by slot blot.
Estefanell-Ucha, Borja; Barcia-Castro, Leticia; Páez de la Cadena, María; Álvarez-Chaver, Paula; Ayude-Vázquez, Daniel; Rodríguez-Berrocal, Francisco Javier
2017-01-01
Clostridium septicum produces a number of diseases in human and farm animals which, in most of the cases, are fatal without clinical intervention. Alpha toxin is an important agent and the unique lethal virulent factor produced by Clostridium septicum. This toxin is haemolytic, highly lethal and necrotizing activities but is being used as an antigen to develop animal vaccines. The aim of this study was to isolate the alpha toxin of Clostridium septicum and produce highly specific antibodies against it. In this work, we have developed a simple and efficient method for alpha toxin purification, based on electroelution that can be used as a time-saving method for purifying proteins. This technique avoids contamination by other proteins that could appear during other protein purification techniques such chromatography. The highly purified toxin was used to produce polyclonal antibodies. The specificity of the antibodies was tested by western blot and these antibodies can be applied to the quantitative determination of alpha toxin by slot blot. PMID:28652930
Guo, Pengfei; Shen, Xia; Zhang, Baolong; Sun, Haibin; Zou, Zhijun; Yang, Wenchao; Gong, Ke; Luo, Yongsong
2018-05-04
A simple two-step CVD method is developed to realize the growth of high-quality tin-catalyzed CdSSe alloy nanowires. Microstructural characterizations demonstrate that these wires are high-quality crystalline nanostructures. Local photoluminescence investigation of these nanostructures shows a typical band edge emission at 656 nm with a full-width at half-maximum of 22.3 nm. Optical waveguide measurement along an individual nanowire indicates that the output signal of the guided light has a rapid linear decrease accompanied with maximum red-shift about 109 meV after the transmission of 102 μm. This obvious red-shift is caused by the intensive band-tail absorption during the optical transmission process. Moreover, optically pumped nanolasers are successfully realized at room temperature based on these unique wires, further demonstrating the achievement of stimulated emission from spontaneous emission, promoted by the pump power intensity. This work may find a simple route to the manufacture of superior nanowires for applications in waveguide and integrated photonic devices.
Choi, Kyung Min; Lee, Seok Jae; Choi, Jung Hoon; Park, Tae Jung; Park, Jong Wan; Shin, Weon Ho; Kang, Jeung Ku
2010-12-07
A facile route to fabricate a protein-immobilized network pattern circuit for rapid and highly sensitive diagnosis was developed via the evaporation directed impromptu patterning method and selective avian influenza virus (AIV) immobilization. The response to the 10 fg mL(-1) anti-AI antibody demonstrates that this easy and simple circuit has about 1000 times higher sensitivity compared to those of conventional approaches.
Dunbar, W E; Schilt, A A
1972-09-01
Seven new hydroxy-substituted 1,10-phenanthroline derivatives have been evaluated as chromogenic reagents for the determination of copper in strongly alkaline solution. The most sensitive of these, 2,9-dimethyl-4,7-dihydroxy-1,10-phenanthroline, has proven to be highly effective in a simple, rapid procedure for determining trace amounts of copper in sodium hydroxide, potassium carbonate, sodium phosphate or ammonium hydroxide.
Lowekamp, Bradley C; Chen, David T; Ibáñez, Luis; Blezek, Daniel
2013-01-01
SimpleITK is a new interface to the Insight Segmentation and Registration Toolkit (ITK) designed to facilitate rapid prototyping, education and scientific activities via high level programming languages. ITK is a templated C++ library of image processing algorithms and frameworks for biomedical and other applications, and it was designed to be generic, flexible and extensible. Initially, ITK provided a direct wrapping interface to languages such as Python and Tcl through the WrapITK system. Unlike WrapITK, which exposed ITK's complex templated interface, SimpleITK was designed to provide an easy to use and simplified interface to ITK's algorithms. It includes procedural methods, hides ITK's demand driven pipeline, and provides a template-less layer. Also SimpleITK provides practical conveniences such as binary distribution packages and overloaded operators. Our user-friendly design goals dictated a departure from the direct interface wrapping approach of WrapITK, toward a new facade class structure that only exposes the required functionality, hiding ITK's extensive template use. Internally SimpleITK utilizes a manual description of each filter with code-generation and advanced C++ meta-programming to provide the higher-level interface, bringing the capabilities of ITK to a wider audience. SimpleITK is licensed as open source software library under the Apache License Version 2.0 and more information about downloading it can be found at http://www.simpleitk.org.
Autonomously Self-Adhesive Hydrogels as Building Blocks for Additive Manufacturing.
Deng, Xudong; Attalla, Rana; Sadowski, Lukas P; Chen, Mengsu; Majcher, Michael J; Urosev, Ivan; Yin, Da-Chuan; Selvaganapathy, P Ravi; Filipe, Carlos D M; Hoare, Todd
2018-01-08
We report a simple method of preparing autonomous and rapid self-adhesive hydrogels and their use as building blocks for additive manufacturing of functional tissue scaffolds. Dynamic cross-linking between 2-aminophenylboronic acid-functionalized hyaluronic acid and poly(vinyl alcohol) yields hydrogels that recover their mechanical integrity within 1 min after cutting or shear under both neutral and acidic pH conditions. Incorporation of this hydrogel in an interpenetrating calcium-alginate network results in an interfacially stiffer but still rapidly self-adhesive hydrogel that can be assembled into hollow perfusion channels by simple contact additive manufacturing within minutes. Such channels withstand fluid perfusion while retaining their dimensions and support endothelial cell growth and proliferation, providing a simple and modular route to produce customized cell scaffolds.
Synchrony, Waves, and Spatial Hierarchies in the Spread of Influenza
NASA Astrophysics Data System (ADS)
Viboud, Cécile; Bjørnstad, Ottar N.; Smith, David L.; Simonsen, Lone; Miller, Mark A.; Grenfell, Bryan T.
2006-04-01
Quantifying long-range dissemination of infectious diseases is a key issue in their dynamics and control. Here, we use influenza-related mortality data to analyze the between-state progression of interpandemic influenza in the United States over the past 30 years. Outbreaks show hierarchical spatial spread evidenced by higher pairwise synchrony between more populous states. Seasons with higher influenza mortality are associated with higher disease transmission and more rapid spread than are mild ones. The regional spread of infection correlates more closely with rates of movement of people to and from their workplaces (workflows) than with geographical distance. Workflows are described in turn by a gravity model, with a rapid decay of commuting up to around 100 km and a long tail of rare longer range flow. A simple epidemiological model, based on the gravity formulation, captures the observed increase of influenza spatial synchrony with transmissibility; high transmission allows influenza to spread rapidly beyond local spatial constraints.
The transition to value-based care.
Ray, Jordan C; Kusumoto, Fred
2016-10-01
Delivery of medical care is evolving rapidly worldwide. Over the past several years in the USA, there has been a rapid shift in reimbursement from a simple fee-for-service model to more complex models that attempt to link payment to quality and value. Change in any large system can be difficult, but with medicine, the transition to a value-based system has been particularly hard to implement because both quality and cost are difficult to quantify. Professional societies and other medical groups are developing different programs in an attempt to define high value care. However, applying a national standard of value for any treatment is challenging, since value varies from person to person, and the individual benefit must remain the central tenet for delivering best patient-centered medical care. Regardless of the specific operational features of the rapidly changing healthcare environment, physicians must first and foremost always remain patient advocates.
Accelerated exploration of multi-principal element alloys with solid solution phases
Senkov, O.N.; Miller, J.D.; Miracle, D.B.; Woodward, C.
2015-01-01
Recent multi-principal element, high entropy alloy (HEA) development strategies vastly expand the number of candidate alloy systems, but also pose a new challenge—how to rapidly screen thousands of candidate alloy systems for targeted properties. Here we develop a new approach to rapidly assess structural metals by combining calculated phase diagrams with simple rules based on the phases present, their transformation temperatures and useful microstructures. We evaluate over 130,000 alloy systems, identifying promising compositions for more time-intensive experimental studies. We find the surprising result that solid solution alloys become less likely as the number of alloy elements increases. This contradicts the major premise of HEAs—that increased configurational entropy increases the stability of disordered solid solution phases. As the number of elements increases, the configurational entropy rises slowly while the probability of at least one pair of elements favouring formation of intermetallic compounds increases more rapidly, explaining this apparent contradiction. PMID:25739749
Balog, Julia; Perenyi, Dora; Guallar-Hoyas, Cristina; Egri, Attila; Pringle, Steven D; Stead, Sara; Chevallier, Olivier P; Elliott, Chris T; Takats, Zoltan
2016-06-15
Increasingly abundant food fraud cases have brought food authenticity and safety into major focus. This study presents a fast and effective way to identify meat products using rapid evaporative ionization mass spectrometry (REIMS). The experimental setup was demonstrated to be able to record a mass spectrometric profile of meat specimens in a time frame of <5 s. A multivariate statistical algorithm was developed and successfully tested for the identification of animal tissue with different anatomical origin, breed, and species with 100% accuracy at species and 97% accuracy at breed level. Detection of the presence of meat originating from a different species (horse, cattle, and venison) has also been demonstrated with high accuracy using mixed patties with a 5% detection limit. REIMS technology was found to be a promising tool in food safety applications providing a reliable and simple method for the rapid characterization of food products.
Rapid Prototyping of Continuous Fiber Reinforced Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Vaidyanathan, R.; Green, C.; Phillips, T.; Cipriani, R.; Yarlagadda, S.; Gillespie, J.; Effinger, M.; Cooper, K. C.; Gordon, Gail (Technical Monitor)
2002-01-01
For ceramics to be used as structural components in high temperature applications, their fracture toughness is improved by embedding continuous ceramic fibers. Ceramic matrix composite (CMC) materials allow increasing the overall operating temperature, raising the temperature safety margins, avoiding the need for cooling, and improving the damping capacity, while reducing the weight at the same time. They also need to be reliable and available in large quantities as well. In this paper, an innovative rapid prototyping technique to fabricate continuous fiber reinforced ceramic matrix composites is described. The process is simple, robust and will be widely applicable to a number of high temperature material systems. This technique was originally developed at the University of Delaware Center for Composite Materials (UD-CCM) for rapid fabrication of polymer matrix composites by a technique called automated tow placement or ATP. The results of mechanical properties and microstructural characterization are presented, together with examples of complex shapes and parts. It is believed that the process will be able to create complex shaped parts at an order of magnitude lower cost than current CVI and PIP processes.
Ultrasonic Monitoring of Setting and Strength Development of Ultra-High-Performance Concrete.
Yoo, Doo-Yeol; Shin, Hyun-Oh; Yoon, Young-Soo
2016-04-19
In this study, the setting and tensile strength development of ultra-high-performance concrete (UHPC) at a very early age was investigated by performing the penetration resistance test (ASTM C403), as well as the direct tensile test using the newly developed test apparatus, and taking ultrasonic pulse velocity (UPV) measurements. In order to determine the optimum surface treatment method for preventing rapid surface drying of UHPC, four different methods were examined: plastic sheet, curing cover, membrane-forming compound, and paraffin oil. Based on the test results, the use of paraffin oil was found to be the best choice for measuring the penetration resistance and the UPV, and attaching the plastic sheet to the exposed surface was considered to be a simple method for preventing the rapid surface drying of UHPC elements. An S-shaped tensile strength development at a very early age (before 24 h) was experimentally obtained, and it was predicted by a power function of UPV. Lastly, the addition of shrinkage-reducing and expansive admixtures resulted in more rapid development of penetration resistance and UPV of UHPC.
Lin, Jung-Fu; Ge, Mao-Cheng; Liu, Tsui-Ping; Chang, Shih-Cheng; Lu, Jang-Jih
2017-06-30
Rapid identification of microbes in the bloodstream is crucial in managing septicemia because of its high disease severity, and direct identification from positive blood culture bottles through matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) can shorten the turnaround time. Therefore, we developed a simple method for rapid microbiological identification from positive blood cultures by using MALDI-TOF MS. We modified previously developed methods to propose a faster, simpler and more economical method, which includes centrifugation and hemolysis. Specifically, our method comprises two-stage centrifugation with gravitational acceleration (g) at 600g and 3000g, followed by the addition of a lysis buffer and another 3000g centrifugation. In total, 324 monomicrobial bacterial cultures were identified. The success rate of species identification was 81.8%, which is comparable with other complex methods. The identification success rate was the highest for Gram-negative aerobes (85%), followed by Gram-positive aerobes (78.2%) and anaerobes (67%). The proposed method requires less than 10 min, costs less than US$0.2 per usage, and facilitates batch processing. We conclude that this method is feasible for clinical use in microbiology laboratories, and can serve as a reference for treatments or further complementary diagnostic testing. Copyright © 2017. Published by Elsevier B.V.
Chiappini, Ciro; Martinez, Jonathan O.; De Rosa, Enrica; Almeida, Carina S.
2016-01-01
Nanoneedles display potential in mediating the delivery of drugs and biologicals, as well as intracellular sensing and single cell stimulation through direct access to the cell cytoplasm. Nanoneedles enable cytosolic delivery, negotiating the cell membrane and the endolysosomal system, thus overcoming these major obstacles to the efficacy of nanotherapeutics. The low toxicity and minimal invasiveness of nanoneedles has a potential for the sustained non-immunogenic delivery of payloads in vivo, provided that the development of biocompatible nanoneedles with a simple deployment strategy is achieved. Here we present a mesoporous silicon nanoneedle array that achieves a tight interface with the cell, rapidly negotiating local biological barriers to grant temporary access to the cytosol with minimal impact on cell viability. The tightness of this interfacing enables both delivery of cell-impermeant quantum dots in vivo and live intracellular sensing of pH. Dissecting the biointerface over time elucidated the dynamics of cell association and nanoneedle biodegradation, showing rapid interfacing leading to cytosolic payload delivery within less than 30 minutes in vitro. The rapid and simple application of nanoneedles in vivo to the surface of tissues with different architectures invariably resulted in the localized delivery of quantum dots to the superficial cells and their prolonged retention. This investigation provides an understanding of the dynamics of nanoneedles’ biointerface and delivery outlining a strategy for highly local intracellular delivery of nanoparticles and cell-impermeant payloads within live tissues. PMID:25858596
The application of sensitivity analysis to models of large scale physiological systems
NASA Technical Reports Server (NTRS)
Leonard, J. I.
1974-01-01
A survey of the literature of sensitivity analysis as it applies to biological systems is reported as well as a brief development of sensitivity theory. A simple population model and a more complex thermoregulatory model illustrate the investigatory techniques and interpretation of parameter sensitivity analysis. The role of sensitivity analysis in validating and verifying models, and in identifying relative parameter influence in estimating errors in model behavior due to uncertainty in input data is presented. This analysis is valuable to the simulationist and the experimentalist in allocating resources for data collection. A method for reducing highly complex, nonlinear models to simple linear algebraic models that could be useful for making rapid, first order calculations of system behavior is presented.
2011-01-01
A simple method for the synthesis of ZnO nanofilms composed of vertical array of quasi-1D ZnO nanostructures (quasi-NRs) on the surface was demonstrated via a 1D crystal growth of the attached nanoseeds under a rapid hydrolysis process of zinc salts in the presence of ammonia at room temperature. In a typical procedure, by simply controlling the concentration of zinc acetate and ammonia in the reaction, a high density of vertically oriented nanorod-like morphology could be successfully obtained in a relatively short growth period (approximately 4 to 5 min) and at a room-temperature process. The average diameter and the length of the nanostructures are approximately 30 and 110 nm, respectively. The as-prepared quasi-NRs products were pure ZnO phase in nature without the presence of any zinc complexes as confirmed by the XRD characterisation. Room-temperature optical absorption spectroscopy exhibits the presence of two separate excitonic characters inferring that the as-prepared ZnO quasi-NRs are high-crystallinity properties in nature. The mechanism of growth for the ZnO quasi-NRs will be proposed. Due to their simplicity, the method should become a potential alternative for a rapid and cost-effective preparation of high-quality ZnO quasi-NRs nanofilms for use in photovoltaic or photocatalytics applications. PACS: 81.07.Bc; 81.16.-c; 81.07.Gf. PMID:22027275
Tada, Atsuko; Ishizuki, Kyoko; Yamazaki, Takeshi; Sugimoto, Naoki; Akiyama, Hiroshi
2014-07-01
Natural ester-type gum bases, which are used worldwide as food additives, mainly consist of wax esters composed of long-chain fatty acids and long-chain fatty alcohols. There are many varieties of ester-type gum bases, and thus a useful method for their discrimination is needed in order to establish official specifications and manage their quality control. Herein is reported a rapid and simple method for the analysis of different ester-type gum bases used as food additives by high-temperature gas chromatography/mass spectrometry (GC/MS). With this method, the constituent wax esters in ester-type gum bases can be detected without hydrolysis and derivatization. The method was applied to the determination of 10 types of gum bases, including beeswax, carnauba wax, lanolin, and jojoba wax, and it was demonstrated that the gum bases derived from identical origins have specific and characteristic total ion chromatogram (TIC) patterns and ester compositions. Food additive gum bases were thus distinguished from one another based on their TIC patterns and then more clearly discriminated using simultaneous monitoring of the fragment ions corresponding to the fatty acid moieties of the individual molecular species of the wax esters. This direct high-temperature GC/MS method was shown to be very useful for the rapid and simple discrimination of varieties of ester-type gum bases used as food additives.
Qi, Yingying; Xiu, Fu-Rong; Yu, Gending; Huang, Lili; Li, Baoxin
2017-01-15
Detection of ultralow concentration of heavy metal ion Hg 2+ is important for human health protection and environment monitoring because of the gradual accumulation in environmental and biological fields. Herein, we report a convenient chemiluminescence (CL) biosensing platform for ultrasensitive Hg 2+ detection by signal amplification mechanism from positively charged gold nanoparticles ((+)AuNPs). It is based on (+)AuNPs charge effect and aptamer conformation change induced by target to stimulate the generation of CL in the presence of H 2 O 2 and luminol without high salt medium. Notably particularly, the typical problem of the high salt medium from (-) AuNPs system, like influencing aptamers' bind with target and hindering CL reaction can be effectively addressed through the direct introduction of (+)AuNPs. Therefore, the proposed biosensing exhibits a high sensitivity toward target Hg 2+ with a detection limit of 16 pM, which is far below the limit (10nM) defined by the U.S. Environmental Protection Agency in drinkable water, and is about 10-fold lower than the previously reported aptamer-based assays for Hg 2+ . This sensing platform provides a simple, rapid, and cost-effective approach for label-free sensitive detection of Hg 2+ . Moreover, it is universal for the detection of other targets. Undoubtedly, such a direct utilizing of (+)AuNPs' charge effect will provide a new signal amplification way for label-free aptamer-based CL analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Tada, Atsuko; Ishizuki, Kyoko; Yamazaki, Takeshi; Sugimoto, Naoki; Akiyama, Hiroshi
2014-01-01
Natural ester-type gum bases, which are used worldwide as food additives, mainly consist of wax esters composed of long-chain fatty acids and long-chain fatty alcohols. There are many varieties of ester-type gum bases, and thus a useful method for their discrimination is needed in order to establish official specifications and manage their quality control. Herein is reported a rapid and simple method for the analysis of different ester-type gum bases used as food additives by high-temperature gas chromatography/mass spectrometry (GC/MS). With this method, the constituent wax esters in ester-type gum bases can be detected without hydrolysis and derivatization. The method was applied to the determination of 10 types of gum bases, including beeswax, carnauba wax, lanolin, and jojoba wax, and it was demonstrated that the gum bases derived from identical origins have specific and characteristic total ion chromatogram (TIC) patterns and ester compositions. Food additive gum bases were thus distinguished from one another based on their TIC patterns and then more clearly discriminated using simultaneous monitoring of the fragment ions corresponding to the fatty acid moieties of the individual molecular species of the wax esters. This direct high-temperature GC/MS method was shown to be very useful for the rapid and simple discrimination of varieties of ester-type gum bases used as food additives. PMID:25473499
Rapid Analysis of Corni fructus Using Paper Spray-Mass Spectrometry.
Guo, Yuan; Gu, Zhixin; Liu, Xuemei; Liu, Jingjing; Ma, Ming; Chen, Bo; Wang, Liping
2017-07-01
Paper spray-mass spectrometry (PS-MS) is a kind of ambient MS technique for the rapid analysis of samples. Corni fructus has been widely used in traditional Chinese compound preparations and healthy food. However, a number of counterfeits of Corni fructus, such as Crataegi fructus, Lycii fructus, and grape skin are illegally sold in crude herb markets. Therefore, the development of a rapid and high-throughput quality evaluation method is important for ensuring the effectiveness and safety of the crude materials of Corni fructus. To develop PS-MS chemical profiles and a semi-quantitative method of Corni fructus for quality assessment and control, and species distinction of Corni fructus. Both positive and negative ion PS-MS chemical profiles were constructed for species distinction. The statistical analysis of the chemical profiles was accomplished by principal component analysis (PCA). Rapid semi-quantitative analysis of loganin and morroniside in the extracts of Corni fructus were accomplished by PS-MS. The profiles of the Corni fructus and Crataegi fructus samples were clearly clustered into two categories. The limit of quantification (LOQ) in the semi-quantitative analysis was 6 μg/mL and 5.6 μg/mL for loganin and morroniside, respectively. PS-MS is a simple, rapid, and high-throughput method for the quality control and species distinction of Corni fructus. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Srivastava, Abhishek; Waterhouse, David; Ardrey, Alison; Ward, Stephen A
2012-11-01
A highly sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed to measure the levels of the antitubercular drug rifampicin (RIF) in human plasma and cerebrospinal fluid (CSF). The analyte and internal standard (IS) were isolated from plasma and CSF by a simple organic solvent based precipitation of proteins followed by centrifugation. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 25-6400 ng/mL with intra- and inter-day precision of <7% and <8%, respectively. The validated method was applied to the study of RIF pharmacokinetics in human CSF and plasma over 25 h period after a 10 mg/kg oral dose. Copyright © 2012 Elsevier B.V. All rights reserved.
Fonseca, M E; Marcellino, L H; Gander, E
1996-04-05
A rapid and sensitive dot-blot hybridization assay using in vitro-transcribed digoxigenin-labelled RNA probes (riboprobes) was developed aiming at detection of citrus exocortis viroid (CEVd) in crude sap of infected Citrus medica plants. The protocol includes a very quick and simple preparation of RNA extracts from samples using a denaturation step with formaldehyde. From our results, the employment of this step is highly recommended because the hybridization signals in formaldehyde-denatured samples were significantly stronger when compared with that of extracts without formaldehyde treatment. The assay was found to be sensitive enough to detect 0.1 ng of purified CEVd RNA and was able to detect viroid in 0.2 mg of symptomatic Citrus medica leaves. The use of riboprobes also allowed hybridization under high temperature conditions, avoiding non-specific background.
Startup analysis for a high temperature gas loaded heat pipe
NASA Technical Reports Server (NTRS)
Sockol, P. M.
1973-01-01
A model for the rapid startup of a high-temperature gas-loaded heat pipe is presented. A two-dimensional diffusion analysis is used to determine the rate of energy transport by the vapor between the hot and cold zones of the pipe. The vapor transport rate is then incorporated in a simple thermal model of the startup of a radiation-cooled heat pipe. Numerical results for an argon-lithium system show that radial diffusion to the cold wall can produce large vapor flow rates during a rapid startup. The results also show that startup is not initiated until the vapor pressure p sub v in the hot zone reaches a precise value proportional to the initial gas pressure p sub i. Through proper choice of p sub i, startup can be delayed until p sub v is large enough to support a heat-transfer rate sufficient to overcome a thermal load on the heat pipe.
Wu, Cuiqin; Yuan, Dongxing; Liu, Baomin
2006-12-01
An analytical method involving anion exchange high performance liquid chromatographic determination of vitellogenin (Vtg) in fish plasma after postcolumn fluorescence derivatization with o-phthalaldehyde (OPA) was developed. The retention time of Vtg was about 11 min. The reagent variables for derivatization were optimized. The fluorophore was excited at 335 nm and detected at 435 nm. A calibration curve was established ranging from 0.13 to 11.28 microg. The determination limit of Vtg was found to be as low as 0.13 microg. The spiked recovery was 93.6% and interassay variability was less than 4%. The method developed was used to determine Vtg in fish plasma obtained from red sea bream (Pagrosomus major), black porgy (Sparus macrocephalus) and skew band grunt (Hapalogenys nitens), without complicated sample pretreatment. The results confirmed that the method showed advantages of being simple, rapid, reproducible and sensitive.
Sim, Hwansu; Kim, Chanho; Bok, Shingyu; Kim, Min Ki; Oh, Hwisu; Lim, Guh-Hwan; Cho, Sung Min; Lim, Byungkwon
2018-06-18
Silver (Ag) nanowires (NWs) are promising building blocks for flexible transparent electrodes, which are key components in fabricating soft electronic devices such as flexible organic light emitting diodes (OLEDs). Typically, Ag NWs have been synthesized using a polyol method, but it still remains a challenge to produce high-aspect-ratio Ag NWs via a simple and rapid process. In this work, we developed a modified polyol method and newly found that the addition of propylene glycol to ethylene glycol-based polyol synthesis facilitated the growth of Ag NWs, allowing the rapid production of long Ag NWs with high aspect ratios of about 2000 in a high yield (∼90%) within 5 min. Transparent electrodes fabricated with our Ag NWs exhibited performance comparable to that of an indium tin oxide-based electrode. With these Ag NWs, we successfully demonstrated the fabrication of a large-area flexible OLED with dimensions of 30 cm × 15 cm using a roll-to-roll process.
Cevenini, Luca; Calabretta, Maria Maddalena; Lopreside, Antonia; Tarantino, Giuseppe; Tassoni, Annalisa; Ferri, Maura; Roda, Aldo; Michelini, Elisa
2016-12-01
The availability of smartphones with high-performance digital image sensors and processing power has completely reshaped the landscape of point-of-need analysis. Thanks to the high maturity level of reporter gene technology and the availability of several bioluminescent proteins with improved features, we were able to develop a bioluminescence smartphone-based biosensing platform exploiting the highly sensitive NanoLuc luciferase as reporter. A 3D-printed smartphone-integrated cell biosensor based on genetically engineered Hek293T cells was developed. Quantitative assessment of (anti)-inflammatory activity and toxicity of liquid samples was performed with a simple and rapid add-and-measure procedure. White grape pomace extracts, known to contain several bioactive compounds, were analyzed, confirming the suitability of the smartphone biosensing platform for analysis of untreated complex biological matrices. Such approach could meet the needs of small medium enterprises lacking fully equipped laboratories for first-level safety tests and rapid screening of new bioactive products. Graphical abstract Smartphone-based bioluminescence cell biosensor.
Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda
2018-02-01
A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new method, now accredited to ISO17025 standard, is simple, quick, applicable to multiple matrices and is highly suitable for use as a routine, high-throughout, fast turnaround regulatory monitoring tool. Copyright © 2017 Elsevier B.V. All rights reserved.
Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.
ERIC Educational Resources Information Center
Pike, R. M.; And Others
1986-01-01
Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)
NASA Astrophysics Data System (ADS)
Li, Shi-Kuo; Hou, Xiao-Cheng; Huang, Fang-Zhi; Li, Chuan-Hao; Kang, Wen-Juan; Xie, An-Jian; Shen, Yu-Hua
2013-11-01
In this paper, we reported a simple and efficient protocol for preparation of Cu2+-modified magnetic Fe3O4@SiO2 core/shell microspheres for immobilization of cellulase. The uniform magnetic Fe3O4@SiO2 core/shell microspheres with a thin shell of 20 nm were synthesized through a solvothermal method followed by a sol-gel process. An amino-terminated silane coupling agent of (3-aminopropyl)triethoxysilane (APTS) was then grafted on them for capturing Cu2+ ions. The reaction process is very simple, efficient, and economical. Noticeably, the content of Cu2+ ions on the magnetic core/shell microspheres can reach 4.6 Wt%, endowing them possess as high immobilization capacity as 225.5 mg/g for cellulase. And the immobilized cellulase can be retained over 90 % on the magnetic microspheres after six cycles. Meanwhile, the magnetic microspheres decorated with Cu2+ ions show a superparamagnetic character with a high magnetic saturation of 58.5 emu/g at room temperature, suggesting conveniently and rapidly recycle the enzyme from solution. This facile, recyclable, high immobilization capacity and activity strategy may find potential applications in enzyme catalytic reactions with low cost.
Armour, John A. L.; Palla, Raquel; Zeeuwen, Patrick L. J. M.; den Heijer, Martin; Schalkwijk, Joost; Hollox, Edward J.
2007-01-01
Recent work has demonstrated an unexpected prevalence of copy number variation in the human genome, and has highlighted the part this variation may play in predisposition to common phenotypes. Some important genes vary in number over a high range (e.g. DEFB4, which commonly varies between two and seven copies), and have posed formidable technical challenges for accurate copy number typing, so that there are no simple, cheap, high-throughput approaches suitable for large-scale screening. We have developed a simple comparative PCR method based on dispersed repeat sequences, using a single pair of precisely designed primers to amplify products simultaneously from both test and reference loci, which are subsequently distinguished and quantified via internal sequence differences. We have validated the method for the measurement of copy number at DEFB4 by comparison of results from >800 DNA samples with copy number measurements by MAPH/REDVR, MLPA and array-CGH. The new Paralogue Ratio Test (PRT) method can require as little as 10 ng genomic DNA, appears to be comparable in accuracy to the other methods, and for the first time provides a rapid, simple and inexpensive method for copy number analysis, suitable for application to typing thousands of samples in large case-control association studies. PMID:17175532
Divide and Conquer (DC) BLAST: fast and easy BLAST execution within HPC environments
Yim, Won Cheol; Cushman, John C.
2017-07-22
Bioinformatics is currently faced with very large-scale data sets that lead to computational jobs, especially sequence similarity searches, that can take absurdly long times to run. For example, the National Center for Biotechnology Information (NCBI) Basic Local Alignment Search Tool (BLAST and BLAST+) suite, which is by far the most widely used tool for rapid similarity searching among nucleic acid or amino acid sequences, is highly central processing unit (CPU) intensive. While the BLAST suite of programs perform searches very rapidly, they have the potential to be accelerated. In recent years, distributed computing environments have become more widely accessible andmore » used due to the increasing availability of high-performance computing (HPC) systems. Therefore, simple solutions for data parallelization are needed to expedite BLAST and other sequence analysis tools. However, existing software for parallel sequence similarity searches often requires extensive computational experience and skill on the part of the user. In order to accelerate BLAST and other sequence analysis tools, Divide and Conquer BLAST (DCBLAST) was developed to perform NCBI BLAST searches within a cluster, grid, or HPC environment by using a query sequence distribution approach. Scaling from one (1) to 256 CPU cores resulted in significant improvements in processing speed. Thus, DCBLAST dramatically accelerates the execution of BLAST searches using a simple, accessible, robust, and parallel approach. DCBLAST works across multiple nodes automatically and it overcomes the speed limitation of single-node BLAST programs. DCBLAST can be used on any HPC system, can take advantage of hundreds of nodes, and has no output limitations. Thus, this freely available tool simplifies distributed computation pipelines to facilitate the rapid discovery of sequence similarities between very large data sets.« less
Divide and Conquer (DC) BLAST: fast and easy BLAST execution within HPC environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yim, Won Cheol; Cushman, John C.
Bioinformatics is currently faced with very large-scale data sets that lead to computational jobs, especially sequence similarity searches, that can take absurdly long times to run. For example, the National Center for Biotechnology Information (NCBI) Basic Local Alignment Search Tool (BLAST and BLAST+) suite, which is by far the most widely used tool for rapid similarity searching among nucleic acid or amino acid sequences, is highly central processing unit (CPU) intensive. While the BLAST suite of programs perform searches very rapidly, they have the potential to be accelerated. In recent years, distributed computing environments have become more widely accessible andmore » used due to the increasing availability of high-performance computing (HPC) systems. Therefore, simple solutions for data parallelization are needed to expedite BLAST and other sequence analysis tools. However, existing software for parallel sequence similarity searches often requires extensive computational experience and skill on the part of the user. In order to accelerate BLAST and other sequence analysis tools, Divide and Conquer BLAST (DCBLAST) was developed to perform NCBI BLAST searches within a cluster, grid, or HPC environment by using a query sequence distribution approach. Scaling from one (1) to 256 CPU cores resulted in significant improvements in processing speed. Thus, DCBLAST dramatically accelerates the execution of BLAST searches using a simple, accessible, robust, and parallel approach. DCBLAST works across multiple nodes automatically and it overcomes the speed limitation of single-node BLAST programs. DCBLAST can be used on any HPC system, can take advantage of hundreds of nodes, and has no output limitations. Thus, this freely available tool simplifies distributed computation pipelines to facilitate the rapid discovery of sequence similarities between very large data sets.« less
Rapidly Synthesized, Few-Layered Pseudocapacitive SnS2 Anode for High-Power Sodium Ion Batteries.
Thangavel, Ranjith; Samuthira Pandian, Amaresh; Ramasamy, Hari Vignesh; Lee, Yun-Sung
2017-11-22
The abundance of sodium resources has recently motivated the investigation of sodium ion batteries (SIBs) as an alternative to commercial lithium ion batteries. However, the low power and low capacity of conventional sodium anodes hinder their practical realization. Although most research has concentrated on the development of high-capacity sodium anodes, anodes with a combination of high power and high capacity have not been widely realized. Herein, we present a simple microwave irradiation technique for obtaining few-layered, ultrathin two-dimensional SnS 2 over graphene sheets in a few minutes. SnS 2 possesses a large number of active surface sites and exhibits high-capacity, rapid sodium ion storage kinetics induced by quick, nondestructive pseudocapacitance. Enhanced sodium ion storage at a high current density (12 A g -1 ), accompanied by high reversibility and high stability, was demonstrated. Additionally, a rationally designed sodium ion full cell coupled with SnS 2 //Na 3 V 2 (PO 4 ) 3 exhibited exceptional performance with high initial Coulombic efficiency (99%), high capacity, high stability, and a retention of ∼53% of the initial capacity even after the current density was increased by a factor of 140. In addition, a high specific energy of ∼140 Wh kg -1 and an ultrahigh specific power of ∼8.3 kW kg -1 (based on the mass of both the anode and cathode) were observed. Because of its outstanding performance and rapid synthesis, few-layered SnS 2 could be a promising candidate for practical realization of high-power SIBs.
Rapid detection of bacteria in foods and biological fluids
NASA Technical Reports Server (NTRS)
Fealey, R. D.; Renner, W.
1973-01-01
Simple and inexpensive apparatus, called "redox monitoring cell," rapidly detects presence of bacteria. Bacteria is detected by measuring drop in oxygen content in test solution. Apparatus consists of vial with two specially designed electrodes connected to sensitive voltmeter.
Rapid characterisation of surface modifications and treatments using a benchtop SIMS instrument
NASA Astrophysics Data System (ADS)
McPhail, D. S.; Sokhan, M.; Rees, E. E.; Cliff, B.; Eccles, A. J.; Chater, R. J.
2004-06-01
The development of a novel benchtop SIMS instrument (Millbrook MiniSIMS) [Appl. Surf. Sci. 144 (1999) 106] has brought routine SIMS analysis to many new users, for example museum conservators. This is a result of the simple operation and the relatively low capital cost of the instrument. We report here on the continued development of the system in terms of increasing performance and functionality and its use in museum conservation based applications where a mobile instrument for high throughput, rapid SIMS analysis has proven to be of great benefit to the user. The example we describe here is the application of the MiniSIMS to the analysis of silver thread woven into a silk dress before and after laser cleaning.
Nordeman, Patrik; Friis, Stig D; Andersen, Thomas L; Audrain, Hélène; Larhed, Mats; Skrydstrup, Troels; Antoni, Gunnar
2015-12-01
Herein, we present a new rapid, efficient, and low-cost radiosynthetic protocol for the conversion of (11) CO2 to (11) CO and its subsequent application in Pd-mediated reactions of importance for PET applications. This room-temperature methodology, using readily available chemical reagents, is carried out in simple glass vials, thus eliminating the need for expensive and specialized high-temperature equipment to access (11) CO. With this fast and near-quantitative conversion of (11) CO2 into (11) CO, aryl and heteroaryl iodides were easily converted into a broad selection of biologically active amides in radiochemical yields ranging from 29-84 %. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Applications of near-infrared spectroscopy to analysis of traditional Chinese herbal medicine].
Li, Yan-Zhou; Min, Shun-Geng; Liu, Xia
2008-07-01
Analysis of traditional Chinese herbal medicine is of great importance to its quality control Conventional analysis methods can not meet the requirement of rapid and on-line analysis because of complex process more experiences or needed. In recent years, near-infrared spectroscopy technique has been used for rapid determination of active components, on-line quality control, identification of counterfeit and discrimination of geographical origins of herbal medicines and so on, due to its advantages of simple pretreatment, high efficiency, convenience to use solid diffuse reflection spectroscopy and fiber. In the present paper, the principles and methods of near-infrared spectroscopy technique are introduced concisely. Especially, the applications of this technique in quantitative analysis and qualitative analysis of traditional Chinese herbal medicine are reviewed.
Li, Guimin; Li, Wangfeng; Liu, Lixia
2012-01-01
Real-time PCR has engendered wide acceptance for quantitation of hepatitis B virus (HBV) DNA in the blood due to its improved rapidity, sensitivity, reproducibility, and reduced contamination. Here we describe a cost-effective and highly sensitive HBV real-time quantitative assay based on the light upon extension real-time PCR platform and a simple and reliable HBV DNA preparation method using silica-coated magnetic beads.
Thermolysis of Geminal Diazides: Reagent-Free Synthesis of 3-Hydroxypyridines.
Erhardt, Hellmuth; Kunz, Kevin A; Kirsch, Stefan F
2017-01-06
An operationally simple protocol for the rapid and efficient construction of highly substituted 3-hydroxypyridines is presented. The thermally induced cyclization of easily constructed geminal diazides derived from β-ketoesters having an additional olefin moiety affords the title compounds in yields up to 97% under reagent-free conditions. The new method allows for the synthesis of preparative quantities of material. Additionally, the synthetic utility of the pyridine products for the synthesis of valuable heterocycles is described.
Electrochemical hydrogen sulfide biosensors.
Xu, Tailin; Scafa, Nikki; Xu, Li-Ping; Zhou, Shufeng; Abdullah Al-Ghanem, Khalid; Mahboob, Shahid; Fugetsu, Bunshi; Zhang, Xueji
2016-02-21
The measurement of sulfide, especially hydrogen sulfide, has held the attention of the analytical community due to its unique physiological and pathophysiological roles in biological systems. Electrochemical detection offers a rapid, highly sensitive, affordable, simple, and real-time technique to measure hydrogen sulfide concentration, which has been a well-documented and reliable method. This review details up-to-date research on the electrochemical detection of hydrogen sulfide (ion selective electrodes, polarographic hydrogen sulfide sensors, etc.) in biological samples for potential therapeutic use.
Discrete elements for 3D microfluidics.
Bhargava, Krisna C; Thompson, Bryant; Malmstadt, Noah
2014-10-21
Microfluidic systems are rapidly becoming commonplace tools for high-precision materials synthesis, biochemical sample preparation, and biophysical analysis. Typically, microfluidic systems are constructed in monolithic form by means of microfabrication and, increasingly, by additive techniques. These methods restrict the design and assembly of truly complex systems by placing unnecessary emphasis on complete functional integration of operational elements in a planar environment. Here, we present a solution based on discrete elements that liberates designers to build large-scale microfluidic systems in three dimensions that are modular, diverse, and predictable by simple network analysis techniques. We develop a sample library of standardized components and connectors manufactured using stereolithography. We predict and validate the flow characteristics of these individual components to design and construct a tunable concentration gradient generator with a scalable number of parallel outputs. We show that these systems are rapidly reconfigurable by constructing three variations of a device for generating monodisperse microdroplets in two distinct size regimes and in a high-throughput mode by simple replacement of emulsifier subcircuits. Finally, we demonstrate the capability for active process monitoring by constructing an optical sensing element for detecting water droplets in a fluorocarbon stream and quantifying their size and frequency. By moving away from large-scale integration toward standardized discrete elements, we demonstrate the potential to reduce the practice of designing and assembling complex 3D microfluidic circuits to a methodology comparable to that found in the electronics industry.
Rapid Inversion: Running Animals and Robots Swing like a Pendulum under Ledges
Mongeau, Jean-Michel; McRae, Brian; Jusufi, Ardian; Birkmeyer, Paul; Hoover, Aaron M.; Fearing, Ronald; Full, Robert J.
2012-01-01
Escaping from predators often demands that animals rapidly negotiate complex environments. The smallest animals attain relatively fast speeds with high frequency leg cycling, wing flapping or body undulations, but absolute speeds are slow compared to larger animals. Instead, small animals benefit from the advantages of enhanced maneuverability in part due to scaling. Here, we report a novel behavior in small, legged runners that may facilitate their escape by disappearance from predators. We video recorded cockroaches and geckos rapidly running up an incline toward a ledge, digitized their motion and created a simple model to generalize the behavior. Both species ran rapidly at 12–15 body lengths-per-second toward the ledge without braking, dove off the ledge, attached their feet by claws like a grappling hook, and used a pendulum-like motion that can exceed one meter-per-second to swing around to an inverted position under the ledge, out of sight. We discovered geckos in Southeast Asia can execute this escape behavior in the field. Quantification of these acrobatic behaviors provides biological inspiration toward the design of small, highly mobile search-and-rescue robots that can assist us during natural and human-made disasters. We report the first steps toward this new capability in a small, hexapedal robot. PMID:22701594
Chen, Yiqin; Bi, Kaixi; Wang, Qianjin; Zheng, Mengjie; Liu, Qing; Han, Yunxin; Yang, Junbo; Chang, Shengli; Zhang, Guanhua; Duan, Huigao
2016-12-27
Focused ion beam (FIB) milling is a versatile maskless and resistless patterning technique and has been widely used for the fabrication of inverse plasmonic structures such as nanoholes and nanoslits for various applications. However, due to its subtractive milling nature, it is an impractical method to fabricate isolated plasmonic nanoparticles and assemblies which are more commonly adopted in applications. In this work, we propose and demonstrate an approach to reliably and rapidly define plasmonic nanoparticles and their assemblies using FIB milling via a simple "sketch and peel" strategy. Systematic experimental investigations and mechanism studies reveal that the high reliability of this fabrication approach is enabled by a conformally formed sidewall coating due to the ion-milling-induced redeposition. Particularly, we demonstrated that this strategy is also applicable to the state-of-the-art helium ion beam milling technology, with which high-fidelity plasmonic dimers with tiny gaps could be directly and rapidly prototyped. Because the proposed approach enables rapid and reliable patterning of arbitrary plasmonic nanostructures that are not feasible to fabricate via conventional FIB milling process, our work provides the FIB milling technology an additional nanopatterning capability and thus could greatly increase its popularity for utilization in fundamental research and device prototyping.
A simple animal support for convenient weighing
Pan, H.P.; Caslick, J.W.; Harke, D.T.; Decker, D.G.
1965-01-01
A simple animal support constructed of web belts to hold skittish pigs for weighing was developed. The support is easily made, noninjurious to the pigs, and compact, facilitating rapid, accurate weighing. With minor modifications, the support can probably be used in weighing other animals.
NASA Astrophysics Data System (ADS)
Baran, Talat; Yılmaz Baran, Nuray; Menteş, Ayfer
2018-05-01
In this study, we reported production, characterization, and catalytic behavior of two novel heterogeneous palladium(II) and platinum(II) catalysts derived from cellulose biopolymer. In order to eliminate the use of toxic organic or inorganic solvents and to reduce the use of excess energy in the coupling reactions, we have developed a very simple, rapid, and eco-friendly microwave irradiation protocol. The developed microwave-assisted method of Suzuki cross coupling reactions produced excellent reaction yields in the presence of cellulose supported palladium and platinum (II) catalysts. Moreover, the catalysts easily regenerated after simple filtration, and they gave good reusability. This study revealed that the designed catalysts and method provide clean, simple, rapid, and impressive catalytic performance for Suzuki coupling reactions.
Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.
Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei
2012-06-01
The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.
Sun, Changhong; Fan, Yu; Li, Juan; Wang, Gancheng; Zhang, Hanshuo; Xi, Jianzhong Jeff
2015-02-01
Transcription activator-like effectors (TALEs) are becoming powerful DNA-targeting tools in a variety of mammalian cells and model organisms. However, generating a stable cell line with specific gene mutations in a simple and rapid manner remains a challenging task. Here, we report a new method to efficiently produce monoclonal cells using integrated TALE nuclease technology and a series of high-throughput cell cloning approaches. Following this method, we obtained three mTOR mutant 293T cell lines within 2 months, which included one homozygous mutant line. © 2014 Society for Laboratory Automation and Screening.
Rao, R Nageswara; Alvi, S Naseeruddin; Rao, B Nageswara
2005-05-27
A simple and rapid preparative high-performance liquid chromatography (HPLC) method has been developed to isolate and characterize some minor impurities of astaxanthin using a normal-phase Lichrosorb silica column with n-hexane-acetone-tetrahydrofuran (90:2:8, v/v/v) as mobile-phase and detection at 475 nm. The isolated impurities were characterized as astacene, dehydro astacene and apoastaxanthinal by UV-vis, ESI-MS, 1H and 13C NMR spectroscopy and the molecular structures were assigned. The impurities collected using the developed conditions were over 98% pure.
An advanced communications synthesizer
NASA Astrophysics Data System (ADS)
Scherer, Ernst F.
1994-02-01
With the proliferation of smaller and lower cost EHF terminals, the fast-hopping microwave synthesizer subsystem is rapidly becoming the limiting factor for further size and cost reduction. A new approach, based on a high-speed direct digital synthesizer (DDS) and a very fast voltage controlled oscillator (VCO) tracking loop, has yielded a highly integrable design with true low-cost potential. A frequency range of 1 to 20 GHz can be covered by a simple substitution of the VCO module. This advanced synthesizer realization promises a generic solution to a large class of synthesizer requirements, greatly facilitating standardization and promoting modular system concepts.
Norrgard, E B; Sitaraman, N; Barry, J F; McCarron, D J; Steinecker, M H; DeMille, D
2016-05-01
We demonstrate a simple and easy method for producing low-reflectivity surfaces that are ultra-high vacuum compatible, may be baked to high temperatures, and are easily applied even on complex surface geometries. Black cupric oxide (CuO) surfaces are chemically grown in minutes on any copper surface, allowing for low-cost, rapid prototyping, and production. The reflective properties are measured to be comparable to commercially available products for creating optically black surfaces. We describe a vacuum apparatus which uses multiple blackened copper surfaces for sensitive, low-background detection of molecules using laser-induced fluorescence.
Rapid and sensitive detection of ketamine in blood using novel fluorescence genosensor.
Ding, Yanjun; Li, Xingmei; Guo, Yadong; Yan, Jie; Ling, Jiang; Li, Weichen; Lan, Lingmei; Chang, Yunfeng; Cai, Jifeng; Zha, Lagabaiyla
2017-12-01
In recent years, drug abuse has been considered as a most challenging social problem that aroused public attention. Ketamine has increased in unregulated use as a 'recreational drug' in teenagers. However, there is no suitable and maneuverable detection method for ketamine in situ at the moment. Fluorescence sensor technique, with predominant recognition and simple operation, is a good potential application in drug detection. Here, we first reported a highly sensitive and selective fluorescence genosensor for rapid detection of ketamine based on DNA-templated silver nanoclusters (DNA-AgNCs) probes, in which the DNA sequence could specially recognize ketamine with high affinity. Parameters affecting detection efficiency were investigated and optimized. Under optimum conditions, the as-prepared genosensor can allow for the determination of ketamine in the concentration range of 0.0001-20 μg/mL with two linear equations: one is y = 2.84x-7.139 (R 2 = 0.987) for 0.0001-0.1 μg/mL, and the other is y = 1.87x-0.091 (R 2 = 0.962) for 0.1-20 μg/mL, and the estimated detection limit of ketamine is 0.06 ng/mL. Moreover, the feasibility of this proposed method was also demonstrated by analyzing forensic blood samples. Compared with official gas chromatography/mass spectrometry (GC/MS), this fluorescence genosensor is simple, rapid, and accurate for quantitative determination of ketamine in blood for pharmaceutical and forensic analysis. Overall, it is the first report on a fluorescence genosensor for detecting ketamine directly in blood. This research may provide a new insight for the analyst to band fluorescence genosensor technology together with drug monitoring in the battle against drug abuse and forensic examination. Graphical abstract High selectively detection of ketamine using a novel fluorescence genosensor based on DNA-AgNCs probe.
Sensitive SERS detection of lead ions via DNAzyme based quadratic signal amplification.
Tian, Aihua; Liu, Yu; Gao, Jian
2017-08-15
Highly sensitive detection of Pb 2+ is very necessary for water quality control, clinical toxicology, and industrial monitoring. In this work, a simple and novel DNAzyme-based SERS quadratic amplification method is developed for the detection of Pb 2+ . This strategy possesses some remarkable features compared to the conventional DNAzyme-based SERS methods, which are as follows: (i) Coupled DNAzyme-activated hybridization chain reaction (HCR) with bio barcodes; a quadratic amplification method is designed using the unique catalytic selectivity of DNAzyme. The SERS signal is significantly amplified. This method is rapid with a detection time of 2h. (ii) The problem of high background induced by excess bio barcodes is circumvented by using magnetic beads (MBs) as the carrier of signal-output products, and this sensing system is simple in design and can easily be carried out by simple mixing and incubation. Given the unique and attractive characteristics, a simple and universal strategy is designed to accomplish sensitive detection of Pb 2+ . The detection limit of Pb 2+ via SERS detection is 70 fM, with the linear range from 1.0×10 -13 M to 1.0×10 -7 M. The method can be further extended to the quantitative detection of a variety of targets by replacing the lead-responsive DNAzyme with other functional DNA. Copyright © 2017 Elsevier B.V. All rights reserved.
Hide, Geoff; Hughes, Jacqueline M; McNuff, Robert
2003-01-01
Background The rapid expansion in the availability of genome and DNA sequence information has opened up new possibilities for the development of methods for detecting free-living protozoa in environmental samples. The protozoan Blepharisma japonicum was used to investigate a rapid and simple detection system based on polymerase chain reaction amplification (PCR) from organisms immobilised on FTA paper. Results Using primers designed from the α-tubulin genes of Blepharisma, specific and sensitive detection to the equivalent of a single Blepharisma cell could be achieved. Similar detection levels were found using water samples, containing Blepharisma, which were dried onto Whatman FTA paper. Conclusion This system has potential as a sensitive convenient detection system for Blepharisma and could be applied to other protozoan organisms. PMID:14516472
Rapid and Programmable Protein Mutagenesis Using Plasmid Recombineering.
Higgins, Sean A; Ouonkap, Sorel V Y; Savage, David F
2017-10-20
Comprehensive and programmable protein mutagenesis is critical for understanding structure-function relationships and improving protein function. There is thus a need for robust and unbiased molecular biological approaches for the construction of the requisite comprehensive protein libraries. Here we demonstrate that plasmid recombineering is a simple and robust in vivo method for the generation of protein mutants for both comprehensive library generation as well as programmable targeting of sequence space. Using the fluorescent protein iLOV as a model target, we build a complete mutagenesis library and find it to be specific and comprehensive, detecting 99.8% of our intended mutations. We then develop a thermostability screen and utilize our comprehensive mutation data to rapidly construct a targeted and multiplexed library that identifies significantly improved variants, thus demonstrating rapid protein engineering in a simple protocol.
Filtration Isolation of Nucleic Acids: A Simple and Rapid DNA Extraction Method.
McFall, Sally M; Neto, Mário F; Reed, Jennifer L; Wagner, Robin L
2016-08-06
FINA, filtration isolation of nucleic acids, is a novel extraction method which utilizes vertical filtration via a separation membrane and absorbent pad to extract cellular DNA from whole blood in less than 2 min. The blood specimen is treated with detergent, mixed briefly and applied by pipet to the separation membrane. The lysate wicks into the blotting pad due to capillary action, capturing the genomic DNA on the surface of the separation membrane. The extracted DNA is retained on the membrane during a simple wash step wherein PCR inhibitors are wicked into the absorbent blotting pad. The membrane containing the entrapped DNA is then added to the PCR reaction without further purification. This simple method does not require laboratory equipment and can be easily implemented with inexpensive laboratory supplies. Here we describe a protocol for highly sensitive detection and quantitation of HIV-1 proviral DNA from 100 µl whole blood as a model for early infant diagnosis of HIV that could readily be adapted to other genetic targets.
Joy, Abraham; Anim-Danso, Emmanuel; Kohn, Joachim
2009-01-01
Methods for the detection and estimation of diphosgene and triphosgene are described. These compounds are widely used phosgene precursors which produce an intensely colored purple pentamethine oxonol dye when reacted with 1,3-dimethylbarbituric acid (DBA) and pyridine (or a pyridine derivative). Two quantitative methods are described, based on either UV absorbance or fluorescence of the oxonol dye. Detection limits are ~ 4 µmol/L by UV and <0.4 µmol/L by fluorescence. The third method is a test strip for the simple and rapid detection and semi-quantitative estimation of diphosgene and triphosgene, using a filter paper embedded with dimethylbarbituric acid and poly(4-vinylpyridine). Addition of a test solution to the paper causes a color change from white to light blue at low concentrations and to pink at higher concentrations of triphosgene. The test strip is useful for quick on-site detection of triphosgene and diphosgene in reaction mixtures. The test strip is easy to perform and provides clear signal readouts indicative of the presence of phosgene precursors. The utility of this method was demonstrated by the qualitative determination of residual triphosgene during the production of poly(Bisphenol A carbonate). PMID:19782219
Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro
2016-01-01
Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.
Rapid and simple method for purification of nucleic acids.
Boom, R; Sol, C J; Salimans, M M; Jansen, C L; Wertheim-van Dillen, P M; van der Noordaa, J
1990-03-01
We have developed a simple, rapid, and reliable protocol for the small-scale purification of DNA and RNA from, e.g., human serum and urine. The method is based on the lysing and nuclease-inactivating properties of the chaotropic agent guanidinium thiocyanate together with the nucleic acid-binding properties of silica particles or diatoms in the presence of this agent. By using size-fractionated silica particles, nucleic acids (covalently closed circular, relaxed circular, and linear double-stranded DNA; single-stranded DNA; and rRNA) could be purified from 12 different specimens in less than 1 h and were recovered in the initial reaction vessel. Purified DNA (although significantly sheared) was a good substrate for restriction endonucleases and DNA ligase and was recovered with high yields (usually over 50%) from the picogram to the microgram level. Copurified rRNA was recovered almost undegraded. Substituting size-fractionated silica particles for diatoms (the fossilized cell walls of unicellular algae) allowed for the purification of microgram amounts of genomic DNA, plasmid DNA, and rRNA from cell-rich sources, as exemplified for pathogenic gram-negative bacteria. In this paper, we show representative experiments illustrating some characteristics of the procedure which may have wide application in clinical microbiology.
Lobo-Júnior, Eulício O; Gabriel, Ellen F M; Dos Santos, Rodrigo A; de Souza, Fabrício R; Lopes, Wanderson D; Lima, Renato S; Gobbi, Angelo L; Coltro, Wendell K T
2017-01-01
This study describes a simple, rapid, and cost-effective fabrication of PDMS electrophoresis microchips using poly(vinyl acetate) (PVAc) emulsion as photoresist master. High-relief microfluidic structures were defined on poly(vinyl acetate) previously deposited on printed circuit boards surfaces without cleanroom facilities and sophisticated instrumentation. After a UV exposure, channels with heights ranging from 30 to 140 μm were obtained by controlling the emulsion mass deposited on the master surface. The developing stage was performed using water rather than the organic solvents that are applied for conventional masks. The surface morphology was characterized by optical imaging, profilometry, and SEM. Based on the achieved results, the proposed method offers suitable reproducibility for the prototyping of electrophoresis microchips in PDMS. The feasibility of the resulting PDMS electrophoresis chips was successfully demonstrated with the separation of major inorganic cations within 100 s using a contactless conductivity detection system. The separation efficiencies ranged from ca. 67 900 to 125 600 plates/m. Due to the satisfactory performance and simplified instrumentation, we believe this fabrication protocol presents potential to be implemented in any chemical, biochemical, or biological laboratory. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis
Kaduri, Maya; Shainsky-Roitman, Janna; Goldfeder, Mor; Ivanir, Eran; Benhar, Itai; Shoham, Yuval; Schroeder, Avi
2016-01-01
Cell-free protein synthesis (CFPS) systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3) and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa). This system was able to produce 40–150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins. PMID:27768741
Simple immunoassay for detection of PCBs in transformer oil.
Glass, Thomas R; Ohmura, Naoya; Taemi, Yukihiro; Joh, Takashi
2005-07-01
A rapid and inexpensive procedure to detect polychlorinated biphenyls (PCBs) in transformer oil is needed to facilitate identification and removal of PCB contaminated transformers. Here we describe a simple two-step liquid-liquid extraction using acidic dimethyl sulfoxide in conjunction with an immunoassay for detecting PCBs in transformer oil. The process described is faster and simpler than any previous immunoassay while maintaining comparable detection limit and false negative rate. Cross reactivity data, characterizing the immunoassay response to the four Kanechlor technical mixtures of PCBs in oil, are presented. Forty-five used transformer oil samples were analyzed by gas chromatography-high-resolution mass spectrometry and were also evaluated using the immunoassay protocol developed. Results presented show zero false negatives at a 1.4 ppm nominal cutoff for the transformer oils analyzed.
Bonney, Laura C; Watson, Robert J; Afrough, Babak; Mullojonova, Manija; Dzhuraeva, Viktoriya; Tishkova, Farida; Hewson, Roger
2017-10-01
Crimean-Congo Haemorrhagic fever Virus (CCHFV) is a rapidly emerging vector-borne pathogen and the cause of a virulent haemorrhagic fever affecting large parts of Europe, Africa, the Middle East and Asia. An isothermal recombinase polymerase amplification (RPA) assay was successfully developed for molecular detection of CCHFV. The assay showed rapid (under 10 minutes) detection of viral extracts/synthetic virus RNA of all 7 S-segment clades of CCHFV, with high target specificity. The assay was shown to tolerate the presence of inhibitors in crude preparations of mock field samples, indicating that this assay may be suitable for use in the field with minimal sample preparation. The CCHFV RPA was successfully used to screen and detect CCHFV positives from a panel of clinical samples from Tajikistan. The assay is a rapid, isothermal, simple-to-perform molecular diagnostic, which can be performed on a light, portable real-time detection device. It is ideally placed therefore for use as a field-diagnostic or in-low resource laboratories, for monitoring of CCHF outbreaks at the point-of-need, such as in remote rural regions in affected countries.
Lowekamp, Bradley C.; Chen, David T.; Ibáñez, Luis; Blezek, Daniel
2013-01-01
SimpleITK is a new interface to the Insight Segmentation and Registration Toolkit (ITK) designed to facilitate rapid prototyping, education and scientific activities via high level programming languages. ITK is a templated C++ library of image processing algorithms and frameworks for biomedical and other applications, and it was designed to be generic, flexible and extensible. Initially, ITK provided a direct wrapping interface to languages such as Python and Tcl through the WrapITK system. Unlike WrapITK, which exposed ITK's complex templated interface, SimpleITK was designed to provide an easy to use and simplified interface to ITK's algorithms. It includes procedural methods, hides ITK's demand driven pipeline, and provides a template-less layer. Also SimpleITK provides practical conveniences such as binary distribution packages and overloaded operators. Our user-friendly design goals dictated a departure from the direct interface wrapping approach of WrapITK, toward a new facade class structure that only exposes the required functionality, hiding ITK's extensive template use. Internally SimpleITK utilizes a manual description of each filter with code-generation and advanced C++ meta-programming to provide the higher-level interface, bringing the capabilities of ITK to a wider audience. SimpleITK is licensed as open source software library under the Apache License Version 2.0 and more information about downloading it can be found at http://www.simpleitk.org. PMID:24416015
An efficient and rapid transgenic pollen screening and detection method using flow cytometry.
Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal
2011-01-01
Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.
A simple and rapid method for high-resolution visualization of single-ion tracks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Omichi, Masaaki; Center for Collaborative Research, Anan National College of Technology, Anan, Tokushima 774-0017; Choi, Wookjin
2014-11-15
Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA)-N, N’-methylene bisacrylamide (MBAAm) blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic forcemore » microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.« less
NASA Technical Reports Server (NTRS)
Boubel, Richard W.
1971-01-01
The stack sampler described in this paper has been developed to overcome the difficulties of particulate sampling with presently available equipment. Its use on emissions from hog fuel fired boilers, back-fired incinerators, wigwam burners, asphalt plants, and seed cleaning cyclones is reported. The results indicate that the sampler is rapid and reliable in its use. It is relatively simple and inexpensive to operate. For most sources it should be considered over the more complicated and expensive sampling trains being used and specified.
HPLC, MS, and pharmacokinetics of melphalan, bisantrene and 13-cis retinoic acid.
Davis, T P; Peng, Y M; Goodman, G E; Alberts, D S
1982-11-01
High performance liquid chromatographic procedures are described for melphalan, bisantrene, and 13-cis retinoic acid, three important anticancer drugs in various stages of clinical development. The procedures require a rapid and simple sample clean-up followed by a 10-to 20-min chromatographic separation on a reversed-phase C18 column. Precisions are all less than 8% with recoveries greater than 80%. Mass spectrometry confirmation of each drug from patient sample separations is presented to provide unambiguous identification for valid pharmacokinetic parameter determination.
Decarboxylative Fluorination of Aliphatic Carboxylic Acids via Photoredox Catalysis.
Ventre, Sandrine; Petronijevic, Filip R; MacMillan, David W C
2015-05-06
The direct conversion of aliphatic carboxylic acids to the corresponding alkyl fluorides has been achieved via visible light-promoted photoredox catalysis. This operationally simple, redox-neutral fluorination method is amenable to a wide variety of carboxylic acids. Photon-induced oxidation of carboxylates leads to the formation of carboxyl radicals, which upon rapid CO2-extrusion and F(•) transfer from a fluorinating reagent yield the desired fluoroalkanes with high efficiency. Experimental evidence indicates that an oxidative quenching pathway is operable in this broadly applicable fluorination protocol.
One-Pot Isomerization–Cross Metathesis–Reduction (ICMR) Synthesis of Lipophilic Tetrapeptides
2015-01-01
An efficient, versatile and rapid method toward homologue series of lipophilic tetrapeptide derivatives (herein, the opioid peptides H-TIPP-OH and H-DIPP-OH) is reported. High atom economy and a minimal number of synthetic steps resulted from a one-pot tandem isomerization-cross metathesis-reduction sequence (ICMR), applicable both in solution and solid phase methodology. The broadly applicable synthesis proceeds with short reaction times and simple work-up, as illustrated in this work for alkylated opioid tetrapeptides. PMID:24906051
Morris, G J
2009-01-01
A simple assay to monitor the potential for contamination during different steps of cryopreservation is described. The assay is based on the contamination of liquid nitrogen using crystals of sucrose hemi-heptahydrate, these are stable in liquid nitrogen, nitrogen vapour and ambient air and can be monitored by a simple assay which allows contamination risks to be evaluated in a direct, rapid manner.
ERIC Educational Resources Information Center
Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe
2018-01-01
In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…
Nardell, E; Dharmadhikari, A
2010-10-01
Ongoing transmission and re-infection, primarily in congregate settings, is a key factor fueling the global multidrug-resistant/extensively drug-resistant tuberculosis (MDR/XDR-TB) epidemic, especially in association with the human immunodeficiency virus. Even as efforts to broadly implement conventional TB transmission control measures begin, current strategies may be incompletely effective under the overcrowded conditions extant in high-burden, resource-limited settings. Longstanding evidence suggesting that TB patients on effective therapy rapidly become non-infectious and that unsuspected, untreated TB cases account for the most transmission makes a strong case for the implementation of rapid point-of-care diagnostics coupled with fully supervised effective treatment. Among the most important decisions affecting transmission, the choice of an MDR-TB treatment model that includes community-based treatment may offer important advantages over hospital or clinic-based care, not only in cost and effectiveness, but also in transmission control. In the community, too, rapid identification of infectious cases, especially drug-resistant cases, followed by effective, fully supervised treatment, is critical to stopping transmission. Among the conventional interventions available, we present a simple triage and separation strategy, point out that separation is intimately linked to the design and engineering of clinical space and call attention to the pros and cons of natural ventilation, simple mechanical ventilation systems, germicidal ultraviolet air disinfection, fit-tested respirators on health care workers and short-term use of masks on patients before treatment is initiated.
NASA Astrophysics Data System (ADS)
Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth
2013-03-01
Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.
Interpreting single jet measurements in Pb$+$Pb collisions at the LHC
Spousta, Martin; Cole, Brian
2016-01-27
Results are presented from a phenomenological analysis of recent measurements of jet suppression and modifications of jet fragmentation functions in Pb+Pb collisions at the LHC. Particular emphasis is placed on the impact of the differences between quark and gluon jet quenching on the transverse momentum (p jet T) dependence of the jet R AA and on the fragmentation functions, D(z). Primordial quark and gluon parton distributions were obtained from PYTHIA8 and were parameterized using simple power-law functions and extensions to the power-law function which were found to better describe the PYTHIA8 parton spectra. A simple model for the quark energymore » loss based on the shift formalism is used to model R AA and D(z) using both analytic results and using direct Monte-Carlo sampling of the PYTHIA parton spectra. The model is capable of describing the full p jet T, rapidity, and centrality dependence of the measured jet R AA using three effective parameters. A key result from the analysis is that the D(z) modifications observed in the data, excluding the enhancement at low-z, may result primarily from the different quenching of the quarks and gluons. Furthermore, the model is also capable of reproducing the charged hadron R AA at high transverse momentum. Predictions are made for the jet R AA at large rapidities where it has not yet been measured and for the rapidity dependence of D(z).« less
Nardell, E.; Dharmadhikari, A.
2013-01-01
SUMMARY Ongoing transmission and re-infection, primarily in congregate settings, is a key factor fueling the global multidrug-resistant/extensively drug-resistant tuberculosis (MDR/XDR-TB) epidemic, especially in association with the human immunodeficiency virus. Even as efforts to broadly implement conventional TB transmission control measures begin, current strategies may be incompletely effective under the overcrowded conditions extant in high-burden, resource-limited settings. Longstanding evidence suggesting that TB patients on effective therapy rapidly become non-infectious and that unsuspected, untreated TB cases account for the most transmission makes a strong case for the implementation of rapid point-of-care diagnostics coupled with fully supervised effective treatment. Among the most important decisions affecting transmission, the choice of an MDR-TB treatment model that includes community-based treatment may offer important advantages over hospital or clinic-based care, not only in cost and effectiveness, but also in transmission control. In the community, too, rapid identification of infectious cases, especially drug-resistant cases, followed by effective, fully supervised treatment, is critical to stopping transmission. Among the conventional interventions available, we present a simple triage and separation strategy, point out that separation is intimately linked to the design and engineering of clinical space and call attention to the pros and cons of natural ventilation, simple mechanical ventilation systems, germicidal ultraviolet air disinfection, fit-tested respirators on health care workers and short-term use of masks on patients before treatment is initiated. PMID:20843413
Bairi, Venu Gopal; Lim, Jin-Hee; Quevedo, Ivan R; Mudalige, Thilak K; Linder, Sean W
2016-02-01
This investigation reports a rapid and simple screening technique for the quantification of titanium and zinc in commercial sunscreens using portable X-ray fluorescence spectroscopy (pXRF). A highly evolved technique, inductively coupled plasma-mass spectroscopy (ICP-MS) was chosen as a comparative technique to pXRF, and a good correlation (r 2 > 0.995) with acceptable variations (≤25%) in results between both techniques was observed. Analytical figures of merit such as detection limit, quantitation limit, and linear range of the method are reported for the pXRF technique. This method has a good linearity (r 2 > 0.995) for the analysis of titanium (Ti) in the range of 0.4-14.23 wt%, and zinc (Zn) in the range of 1.0-23.90 wt%. However, most commercial sunscreens contain organic ingredients, and these ingredients are known to cause matrix effects. The development of appropriate matrix matched working standards to obtain the calibration curve was found to be a major challenge for the pXRF measurements. In this study, we have overcome the matrix effect by using metal-free commercial sunscreens as a dispersing media for the preparation of working standards. An easy extension of this unique methodology for preparing working standards in different matrices was also reported. This method is simple, rapid, and cost-effective and, in comparison to conventional techniques (e.g., ICP-MS), did not generate toxic wastes during sample analysis.
NASA Astrophysics Data System (ADS)
Bairi, Venu Gopal; Lim, Jin-Hee; Quevedo, Ivan R.; Mudalige, Thilak K.; Linder, Sean W.
2016-02-01
This investigation reports a rapid and simple screening technique for the quantification of titanium and zinc in commercial sunscreens using portable X-ray fluorescence spectroscopy (pXRF). A highly evolved technique, inductively coupled plasma-mass spectroscopy (ICP-MS) was chosen as a comparative technique to pXRF, and a good correlation (r2 > 0.995) with acceptable variations (≤ 25%) in results between both techniques was observed. Analytical figures of merit such as detection limit, quantitation limit, and linear range of the method are reported for the pXRF technique. This method has a good linearity (r2 > 0.995) for the analysis of titanium (Ti) in the range of 0.4-14.23 wt%, and zinc (Zn) in the range of 1.0-23.90 wt%. However, most commercial sunscreens contain organic ingredients, and these ingredients are known to cause matrix effects. The development of appropriate matrix matched working standards to obtain the calibration curve was found to be a major challenge for the pXRF measurements. In this study, we have overcome the matrix effect by using metal-free commercial sunscreens as a dispersing media for the preparation of working standards. An easy extension of this unique methodology for preparing working standards in different matrices was also reported. This method is simple, rapid, and cost-effective and, in comparison to conventional techniques (e.g., ICP-MS), did not generate toxic wastes during sample analysis.
Biniarz, Piotr; Łukaszewicz, Marcin
2017-06-01
The rapid and accurate quantification of biosurfactants in biological samples is challenging. In contrast to the orcinol method for rhamnolipids, no simple biochemical method is available for the rapid quantification of lipopeptides. Various liquid chromatography (LC) methods are promising tools for relatively fast and exact quantification of lipopeptides. Here, we report strategies for the quantification of the lipopeptides pseudofactin and surfactin in bacterial cultures using different high- (HPLC) and ultra-performance liquid chromatography (UPLC) systems. We tested three strategies for sample pretreatment prior to LC analysis. In direct analysis (DA), bacterial cultures were injected directly and analyzed via LC. As a modification, we diluted the samples with methanol and detected an increase in lipopeptide recovery in the presence of methanol. Therefore, we suggest this simple modification as a tool for increasing the accuracy of LC methods. We also tested freeze-drying followed by solvent extraction (FDSE) as an alternative for the analysis of "heavy" samples. In FDSE, the bacterial cultures were freeze-dried, and the resulting powder was extracted with different solvents. Then, the organic extracts were analyzed via LC. Here, we determined the influence of the extracting solvent on lipopeptide recovery. HPLC methods allowed us to quantify pseudofactin and surfactin with run times of 15 and 20 min per sample, respectively, whereas UPLC quantification was as fast as 4 and 5.5 min per sample, respectively. Our methods provide highly accurate measurements and high recovery levels for lipopeptides. At the same time, UPLC-MS provides the possibility to identify lipopeptides and their structural isoforms.
Uney, Kamil; Altan, Feray; Elmas, Muammer
2011-02-01
Cefquinome has a broad spectrum of antibacterial activity and was developed especially for use in animals. A simple and sensitive high-performance liquid chromatography (HPLC) method with UV-visible detection for quantification of cefquinome concentrations in sheep plasma was developed and validated. Separation of cefquinome from plasma components was achieved on a Phenomenex Gemini C(18) column (250 mm by 4.6 mm; internal diameter [i.d.], 5 μm). The mobile phase consisted of acetonitrile and 0.1% trifluoroacetic acid in water and was delivered at a rate of 0.9 ml/min. A simple and rapid sample preparation involved the addition of methanol to 200 μl of plasma to precipitate plasma proteins followed by direct injection of 50 μl of supernatant into the high-performance liquid chromatography system. The linearity range of the proposed method was 0.02 to 12 μg/ml. The intraday and interday coefficients of variation obtained from cefquinome were less than 5%, and biases ranged from -3.76% to 1.24%. Mean recovery based on low-, medium-, and high-quality control standards ranged between 92.0 and 93.9%. Plasma samples were found to be stable in various storage conditions (freeze-thaw, postpreparative, short-term, and long-term stability). The method described was found to be readily available, practicable, cheap, rapid, sensitive, precise, and accurate. It was successfully applied to the study of the pharmacokinetics of cefquinome in sheep. This method can be very useful and an alternate to performing pharmacokinetic studies in the determination of cefquinome for clinical use.
NASA Astrophysics Data System (ADS)
Xu, Wentao; Lee, Yeongjun; Min, Sung-Yong; Park, Cheolmin; Lee, Tae-Woo
2016-09-01
Resistive random-access memory (RRAM) is a candidate next generation nonvolatile memory due to its high access speed, high density and ease of fabrication. Especially, cross-point-access allows cross-bar arrays that lead to high-density cells in a two-dimensional planar structure. Use of such designs could be compatible with the aggressive scaling down of memory devices, but existing methods such as optical or e-beam lithographic approaches are too complicated. One-dimensional inorganic nanowires (i-NWs) are regarded as ideal components of nanoelectronics to circumvent the limitations of conventional lithographic approaches. However, post-growth alignment of these i-NWs precisely on a large area with individual control is still a difficult challenge. Here, we report a simple, inexpensive, and rapid method to fabricate two-dimensional arrays of perpendicularly-aligned, individually-conductive Cu-NWs with a nanometer-scale CuxO layer sandwiched at each cross point, by using an inorganic-nanowire-digital-alignment technique (INDAT) and a one-step reduction process. In this approach, the oxide layer is self-formed and patterned, so conventional deposition and lithography are not necessary. INDAT eliminates the difficulties of alignment and scalable fabrication that are encountered when using currently-available techniques that use inorganic nanowires. This simple process facilitates fabrication of cross-point nonvolatile memristor arrays. Fabricated arrays had reproducible resistive switching behavior, high on/off current ratio (Ion/Ioff) 10 6 and extensive cycling endurance. This is the first report of memristors with the resistive switching oxide layer self-formed, self-patterned and self-positioned; we envision that the new features of the technique will provide great opportunities for future nano-electronic circuits.
Takahashi, Hitoshi; Nagata, Shiho; Odagiri, Takato; Kageyama, Tsutomu
2018-04-15
The H5 subtype of highly pathogenic avian influenza (H5 HPAI) viruses is a threat to both animal and human public health and has the potential to cause a serious future pandemic in humans. Thus, specific and rapid detection of H5 HPAI viruses is required for infection control in humans. To develop a simple and rapid diagnostic system to detect H5 HPAI viruses with high specificity and sensitivity, we attempted to prepare monoclonal antibodies (mAbs) that specifically recognize linear epitopes in hemagglutinin (HA) of H5 subtype viruses. Nine mAb clones were obtained from mice immunized with a synthetic partial peptide of H5 HA molecules conserved among various H5 HPAI viruses. The antigen-capture enzyme-linked immunosorbent assay using the most suitable combination of these mAbs, which bound specifically to lysed H5 HA under an optimized detergent condition, was specific for H5 viruses and could broadly detect H5 viruses in multiple different clades. Taken together, these peptide mAbs, which recognize linear epitopes in a highly conserved region of H5 HA, may be useful for specific and highly sensitive detection of H5 HPAI viruses and can help in the rapid diagnosis of human, avian, and animal H5 virus infections. Copyright © 2018 Elsevier Inc. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Recently several isothermal amplification techniques have been developed that are extremely tolerant towards inhibitors present in many plant extracts. Recombinase polymerase amplification (RPA) assays for the genus Phytophthora have been developed which provide a simple and rapid method to macerate...
Slide-and-exchange mechanism for rapid and selective transport through the nuclear pore complex.
Raveh, Barak; Karp, Jerome M; Sparks, Samuel; Dutta, Kaushik; Rout, Michael P; Sali, Andrej; Cowburn, David
2016-05-03
Nucleocytoplasmic transport is mediated by the interaction of transport factors (TFs) with disordered phenylalanine-glycine (FG) repeats that fill the central channel of the nuclear pore complex (NPC). However, the mechanism by which TFs rapidly diffuse through multiple FG repeats without compromising NPC selectivity is not yet fully understood. In this study, we build on our recent NMR investigations showing that FG repeats are highly dynamic, flexible, and rapidly exchanging among TF interaction sites. We use unbiased long timescale all-atom simulations on the Anton supercomputer, combined with extensive enhanced sampling simulations and NMR experiments, to characterize the thermodynamic and kinetic properties of FG repeats and their interaction with a model transport factor. Both the simulations and experimental data indicate that FG repeats are highly dynamic random coils, lack intrachain interactions, and exhibit significant entropically driven resistance to spatial confinement. We show that the FG motifs reversibly slide in and out of multiple TF interaction sites, transitioning rapidly between a strongly interacting state and a weakly interacting state, rather than undergoing a much slower transition between strongly interacting and completely noninteracting (unbound) states. In the weakly interacting state, FG motifs can be more easily displaced by other competing FG motifs, providing a simple mechanism for rapid exchange of TF/FG motif contacts during transport. This slide-and-exchange mechanism highlights the direct role of the disorder within FG repeats in nucleocytoplasmic transport, and resolves the apparent conflict between the selectivity and speed of transport.
A Novel Technique for Detecting Antibiotic-Resistant Typhoid from Rapid Diagnostic Tests
Nic Fhogartaigh, Caoimhe; Dance, David A. B.; Davong, Viengmon; Tann, Pisey; Phetsouvanh, Rattanaphone; Turner, Paul; Newton, Paul N.
2015-01-01
Fluoroquinolone-resistant typhoid is increasing. An antigen-detecting rapid diagnotic test (RDT) can rapidly diagnose typhoid from blood cultures. A simple, inexpensive molecular technique performed with DNA from positive RDTs accurately identified gyrA mutations consistent with phenotypic susceptibility testing results. Field diagnosis combined with centralized molecular resistance testing could improve typhoid management and surveillance in low-resource settings. PMID:25762768
A simple approach for human recombinant apolipoprotein E4 expression and purification.
Argyri, Letta; Skamnaki, Vassiliki; Stratikos, Efstratios; Chroni, Angeliki
2011-10-01
We report a simple expression and purification procedure for the production of recombinant apolipoprotein E4 (apoE4), an important protein for the lipid homeostasis in humans that plays critical roles in the pathogenesis of cardiovascular and neurodegenerative diseases. Our approach is based on the expression of a thioredoxin-apoE4 fusion construct in bacterial cells and subsequent removal of the fused thioredoxin using the highly specific 3C protease, avoiding costly and laborious lipidation-delipidation steps used before. Our approach results in rapid, high-yield production of structurally and functionally competent apoE4 as evidenced by secondary structure measurements, thermal and chemical melting profiles and the kinetic profile of solubilization of dimyristoyl-phosphatidylcholine (DMPC) vesicles. This protocol is appropriate for laboratories with little experience in apolipoprotein biochemistry and will facilitate future studies on the role of apoE4 in the pathogenesis of cardiovascular disease and neurodegenerative diseases, including Alzheimer's disease. Copyright © 2011 Elsevier Inc. All rights reserved.
Fernandes, Telmo J R; Costa, Joana; Oliveira, M Beatriz P P; Mafra, Isabel
2017-09-01
This work aimed to exploit the use of DNA mini-barcodes combined with high resolution melting (HRM) for the authentication of gadoid species: Atlantic cod (Gadus morhua), Pacific cod (Gadus macrocephalus), Alaska pollock (Theragra chalcogramma) and saithe (Pollachius virens). Two DNA barcode regions, namely cytochrome c oxidase subunit I (COI) and cytochrome b (cytb), were analysed in silico to identify genetic variability among the four species and used, subsequently, to develop a real-time PCR method coupled with HRM analysis. The cytb mini-barcode enabled best discrimination of the target species with a high level of confidence (99.3%). The approach was applied successfully to identify gadoid species in 30 fish-containing foods, 30% of which were not as declared on the label. Herein, a novel approach for rapid, simple and cost-effective discrimination/clustering, as a tool to authenticate Gadidae fish species, according to their genetic relationship, is proposed. Copyright © 2017 Elsevier Ltd. All rights reserved.
In situ eNOS/NO up-regulation—a simple and effective therapeutic strategy for diabetic skin ulcer
Yang, Ye; Yin, Dengke; Wang, Fei; Hou, Ziyan; Fang, Zhaohui
2016-01-01
Decreased nitric oxide (NO) synthesis and increased NO consumption in diabetes induces the inadequate blood flow to tissues that is primarily responsible for the pathogenesis and refractoriness of diabetic skin ulcers. The present study proposed a simple and effective therapeutic strategy for diabetic skin ulcers—in situ up-regulation of endothelial nitric oxide synthase (eNOS) expression and NO synthesis by statin-loaded tissue engineering scaffold (TES). In vitro experiments on human umbilical vein endothelial cells indicated that the statin-loaded TES relieved the high-glucose induced decrease in cell viability and promoted NO synthesis under high-glucose conditions. In a rat model of diabetes, the statin-loaded TES promoted eNOS expression and NO synthesis in/around the regenerated tissues. Subsequently, accelerated vascularization and elevated blood supply were observed, followed by rapid wound healing. These findings suggest that the in situ up-regulation of eNOS/NO by a statin-loaded TES may be a useful therapeutic method for intractable diabetic skin wounds. PMID:27453476
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egestad, B.; Curstedt, T.; Sjoevall, J.
1982-01-01
Procedures for enrichment of non-volatile chlorinated aromatic pollutants from fat, water and milk are described. /sup 14/C-DDT was used as a model compound in recovery experiments. A several thousand-fold enrichment of DDT added to butter was achieved by two consecutive straight-phase chromatographies on Lipidex 5000. Trace amounts of DDT in liter volumes of water could be quantitatively extracted by rapid filtration through 2 ml beds of Lipidex 1000. A batch extraction procedure permitted enrichment of DDT from milk after addition of n-pentylamine, methanol and water. DDT could then be eluted from the gel with retention of more than 90% ofmore » the lipids. A reversed-phase system with Lipidex 5000 could be used for separation of TCDD from DDT and PCBs. The liquid-gel chromatographic procedures are simple and suitable for clean-up of samples prior to application of high-resolution methods. 5 tables.« less
Rauf, Sana; Zhang, Ling; Ali, Asghar; Liu, Yang; Li, Jinghong
2017-02-24
Detection of very low amounts of illicit drugs such as cocaine in clinical fluids like serum continues to be important for many areas in the fight against drug trafficking. Herein, we constructed a label-free nanopore biosensor for rapid and highly sensitive detection of cocaine in human serum and saliva samples based on target-induced strand release strategy. In this bioassay, an aptamer for cocaine was prehybridized with a short complementary DNA. Owing to cocaine specific binding with aptamer, the short DNA strand was displaced from aptamer and translocation of this output DNA through α-hemolysin nanopore generated distinct spike-like current blockages. When plotted in double-logarithmic scale, a linear relationship between target cocaine concentration and output DNA event frequency was obtained in a wide concentration range from 50 nM to 100 μM of cocaine, with the limit of detection down to 50 nM. In addition, this aptamer-based sensor method was successfully applied for cocaine detection in complex biological fluids like human saliva and serum samples with great selectivity. Simple preparation, low cost, rapid, label-free, and real sample detection are the motivating factors for practical application of the proposed biosensor.
Spontaneous rapid reduction of a large acute subdural hematoma.
Lee, Chul-Hee; Kang, Dong Ho; Hwang, Soo Hyun; Park, In Sung; Jung, Jin-Myung; Han, Jong Woo
2009-12-01
The majority of acute post-traumatic subdural hematomas (ASDH) require urgent surgical evacuation. Spontaneous resolution of ASDH has been reported in some cases. We report here on a case of a patient with a large amount of ASDH that was rapidly reduced. A 61-yr-old man was found unconscious following a high speed motor vehicle accident. On initial examination, his Glasgow Coma Score scale was 4/15. His pupils were fully dilated and non-reactive to bright light. Brain computed tomography (CT) showed a massive right-sided ASDH. The decision was made to treat him conservatively because of his poor clinical condition. Another brain CT approximately 14 hr after the initial scan demonstrated a remarkable reduction of the previous ASDH and there was the new appearance of high density in the subdural space adjacent to the falx and the tentorium. Thirty days after his admission, brain CT revealed chronic SDH and the patient underwent surgery. The patient is currently able to obey simple commands. In conclusion, spontaneous rapid resolution/reduction of ASDH may occur in some patients. The mechanisms are most likely the result of dilution by cerebrospinal fluid and the redistribution of hematoma especially in patients with brain atrophy.
Spontaneous Rapid Reduction of a Large Acute Subdural Hematoma
Kang, Dong Ho; Hwang, Soo Hyun; Park, In Sung; Jung, Jin-Myung; Han, Jong Woo
2009-01-01
The majority of acute post-traumatic subdural hematomas (ASDH) require urgent surgical evacuation. Spontaneous resolution of ASDH has been reported in some cases. We report here on a case of a patient with a large amount of ASDH that was rapidly reduced. A 61-yr-old man was found unconscious following a high speed motor vehicle accident. On initial examination, his Glasgow Coma Score scale was 4/15. His pupils were fully dilated and non-reactive to bright light. Brain computed tomography (CT) showed a massive right-sided ASDH. The decision was made to treat him conservatively because of his poor clinical condition. Another brain CT approximately 14 hr after the initial scan demonstrated a remarkable reduction of the previous ASDH and there was the new appearance of high density in the subdural space adjacent to the falx and the tentorium. Thirty days after his admission, brain CT revealed chronic SDH and the patient underwent surgery. The patient is currently able to obey simple commands. In conclusion, spontaneous rapid resolution/reduction of ASDH may occur in some patients. The mechanisms are most likely the result of dilution by cerebrospinal fluid and the redistribution of hematoma especially in patients with brain atrophy. PMID:19949689
Simple & Rapid Generation of Complex DNA Profiles for the Undergraduate Laboratory
ERIC Educational Resources Information Center
Kass, David H.
2007-01-01
Deoxyribonucleic acid (DNA) profiles can be generated by a variety of techniques incorporating different types of DNA markers. Simple methods are commonly utilized in the undergraduate laboratory, but with certain drawbacks. In this article, the author presents an advancement of the "Alu" dimorphism technique involving two tetraplex polymerase…
Simple sequence repeat markers that identify Claviceps species and strains
USDA-ARS?s Scientific Manuscript database
Claviceps purpurea is a pathogen that infects most members of the Pooideae subfamily and causes ergot, a floral disease in which the ovary is replaced with a sclerotium. This study was initiated to develop Simple Sequence Repeat (SSRs) markers for rapid identification of C. purpurea. SSRs were desi...
SIMPLE MINI-METHOD TO EXTRACT BULK DNA DIRECTLY FROM SOIL FOR USE WITH PCR
A rapid, simple method is described, which yields amplifiable bacterial and fungal DNAs from soil. NA is extracted directly from soil and separated from the soil contaminants by electrophoresis in Nusieve GTG agarose. p to fifty 20 mg samples can be processed in one day.
Electrochemical Nanoparticle-Enzyme Sensors for Screening Bacterial Contamination in Drinking Water
Chen, Juhong; Jiang, Ziwen; Ackerman, Jonathan D.; Yazdani, Mahdieh; Hou, Singyuk
2015-01-01
Traditional plating and culturing methods used to quantify bacteria commonly require hours to days from sampling to results. We present here a simple, sensitive and rapid electrochemical method for bacteria detection in drinking water based on gold nanoparticle-enzyme complexes. The gold nanoparticles were functionalized with positively charged quaternary amine headgroups that could bind to enzymes through electrostatic interactions, resulting in inhibition of enzymatic activity. In the presence of bacteria, the nanoparticles released from the enzymes and preferentially bound to the bacteria, resulting in an increase in enzyme activity, releasing a redox-active phenol from the substrate. We employed this strategy for the electrochemical sensing of Escherichia coli and Staphylococcus aureus, resulting in a rapid detection (<1h) with high sensitivity (102 CFU·mL−1). PMID:26042607
Process for production of solution-derived (Pb,La)(Nb,Sn,Zr,Ti)O{sub 3} thin films and powders
Boyle, T.J.
1999-01-12
A simple and rapid process for synthesizing (Pb,La)(Nb,Sn,Zr,Ti)O{sub 3} precursor solutions and subsequent ferroelectric thin films and powders of the perovskite phase of these materials has been developed. This process offers advantages over standard methods, including: rapid solution synthesis (<10 minutes), use of commercially available materials, film production under ambient conditions, ease of lanthanum dissolution at high concentrations, and no heating requirements during solution synthesis. For lanthanum-doped ferroelectric materials, the lanthanum source can be added with total synthesis time less than 10 minutes. Films and powders are crystallized at approximately 650 C and exhibit ferroelectric properties comparable to films and powders produced by other techniques which require higher crystallization temperatures. 2 figs.
Process for production of solution-derived (Pb,La)(Nb,Sn,Zr,Ti)O.sub.3 thin films and powders
Boyle, Timothy J.
1999-01-01
A simple and rapid process for synthesizing (Pb,La)(Nb,Sn,Zr,Ti)O.sub.3 precursor solutions and subsequent ferroelectric thin films and powders of the perovskite phase of these materials has been developed. This process offers advantages over standard methods, including: rapid solution synthesis (<10 minutes), use of commercially available materials, film production under ambient conditions, ease of lanthanum dissolution at high concentrations, and no heating requirements during solution synthesis. For lanthanum-doped ferroelectric materials, the lanthanum source can be added with total synthesis time less than 10 minutes. Films and powders are crystallized at approximately 650.degree. C. and exhibit ferroelectric properties comparable to films and powders produced by other techniques which require higher crystallization temperatures.
Déglon, Julien; Versace, François; Lauer, Estelle; Widmer, Christèle; Mangin, Patrice; Thomas, Aurélien; Staub, Christian
2012-06-01
Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xiaoguang; Department of Medical Microbiology, Harbin Medical University, Harbin 150086; Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811
Highlights: Black-Right-Pointing-Pointer We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. Black-Right-Pointing-Pointer The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. Black-Right-Pointing-Pointer In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviralmore » activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1{sub IIIB} and HIV-1{sub BaL} as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1{sub IIIB} activity, whereas fusion inhibitors showed both anti-HIV-1{sub IIIB} and anti-HIV-1{sub BaL} activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, 'phenotypic drug evaluation', may be applicable for the evaluation of various antiviral drugs in vivo.« less
Drivers of precipitation change: An energetic understanding
NASA Astrophysics Data System (ADS)
Richardson, T.; Forster, P.; Andrews, T.
2016-12-01
Future precipitation changes are highly uncertain. Different drivers of anthropogenic climate change can cause very different hydrological responses, which could have significant societal implications. Changes in precipitation are tightly linked to the atmospheric energy budget due to the latent heat released through condensation. Through analysis of the atmospheric energy budget we make significant steps forward in understanding and predicting the precipitation response to different forcings. Here we analyse the response to five targeted forcing scenarios (perturbed CO2, CH4, black carbon, sulphate and solar insolation) across eight climate models participating in the Precipitation Driver and Response Model Intercomparison Project (PDRMIP). The resulting changes are split into a rapid adjustment component, due to the near-instantaneous changes in the atmospheric energy budget, and a feedback component which scales with surface temperature change. Globally, CO2 and black carbon produce large negative adjustments in precipitation due to the increase in atmospheric absorption. However, over land it is sulphate and solar forcing which produce the largest precipitation adjustments due to changes in horizontal energy transport associated with rapid circulation changes. Globally, the precipitation feedback response is very consistent between forcing scenarios, driven mainly by increased longwave cooling. The feedback response differs significantly over land and sea, with a larger feedback over the oceans. We use the PDRMIP results to construct a simple model for precipitation change over land and sea based on surface temperature change and top of the atmosphere forcing. The simple model matches well with CMIP5 ensemble mean precipitation change for RCP8.5. Simulated changes in land mean precipitation can be estimated well using the rapid adjustment and feedback framework, and understood through simple energy budget arguments. Up until present day the effects of temperature change on land mean precipitation have been entirely masked by sulphate forcing. However, as projected sulphate forcing decreases, and warming continues, the temperature driven increase in land mean precipitation soon dominates.
Highly crumpled solar reduced graphene oxide electrode for supercapacitor application
NASA Astrophysics Data System (ADS)
Mohanapriya, K.; Ahirrao, Dinesh J.; Jha, Neetu
2018-04-01
Highly crumpled solar reduced graphene oxide (CSRGO) was synthesized by simple and rapid method through freezing the solar reduced graphene oxide aqueous suspension using liquid nitrogen and used as electrode material for supercapacitor application. This electrode material was characterized by transmission electron microscope (TEM), X-Ray diffractometer (XRD) and Raman Spectroscopy techniques to understand the morphology and structure. The electrochemical performance was studied by cyclic voltammetry (CV), galvanostatic charge/discharge (CD) and electrochemical impedance spectroscopy (EIS) using 6M KOH electrolyte. The CSRGO exhibit high specifc capacitance of 210.1 F g-1 at the current density of 0.5 A g-1 and shows excellent rate capability. These features make the CSRGO material as promising electrode for high-performance supercapacitors.
Rodriguez-Saona, L E; Koca, N; Harper, W J; Alvarez, V B
2006-05-01
There is a need for rapid and simple techniques that can be used to predict the quality of cheese. The aim of this research was to develop a simple and rapid screening tool for monitoring Swiss cheese composition by using Fourier transform infrared spectroscopy. Twenty Swiss cheese samples from different manufacturers and degree of maturity were evaluated. Direct measurements of Swiss cheese slices (approximately 0.5 g) were made using a MIRacle 3-reflection diamond attenuated total reflectance (ATR) accessory. Reference methods for moisture (vacuum oven), protein content (Kjeldahl), and fat (Babcock) were used. Calibration models were developed based on a cross-validated (leave-one-out approach) partial least squares regression. The information-rich infrared spectral range for Swiss cheese samples was from 3,000 to 2,800 cm(-1) and 1,800 to 900 cm(-1). The performance statistics for cross-validated models gave estimates for standard error of cross-validation of 0.45, 0.25, and 0.21% for moisture, protein, and fat respectively, and correlation coefficients r > 0.96. Furthermore, the ATR infrared protocol allowed for the classification of cheeses according to manufacturer and aging based on unique spectral information, especially of carbonyl groups, probably due to their distinctive lipid composition. Attenuated total reflectance infrared spectroscopy allowed for the rapid (approximately 3-min analysis time) and accurate analysis of the composition of Swiss cheese. This technique could contribute to the development of simple and rapid protocols for monitoring complex biochemical changes, and predicting the final quality of the cheese.
Chen, Shuo; Chang, Quanying; Yin, Kai; He, Qunying; Deng, Yongxiu; Chen, Bo; Liu, Chengbin; Wang, Ying; Wang, Liping
2017-06-14
In this study, a paper spray ionization mass spectrometric (PS-MS) method was developed for the rapid in situ screening and simultaneous quantitative analysis of bisphenol A and its analogues, i.e., bisphenol S, bisphenol F, and bisphenol AF, in food packaging products. At the optimal PS-MS conditions, the calibration curves of bisphenols in the range of 1-100 μg/mL were linear. The correlation coefficients were higher than 0.998, and the LODs of the target compounds were 0.1-0.3 μg/mL. After a simple treatment by dichloromethane on the surface, the samples were analyzed by PS-MS in situ for rapid screening without a traditional sample pretreatment procedure, such as powdering, extraction, and enrichment steps. The analytical time of the PS-MS method was less than 1 min. In comparison with conventional HPLC-MS/MS, it was demonstrated that PS-MS was a more effective high-throughput screening and quantitative analysis method.
Borson, Soo; Scanlan, James M.; Sadak, Tatiana; Lessig, Mary; Vitaliano, Peter
2014-01-01
Objective The National Alzheimer’s Plan calls for targeted health system change to improve outcomes for persons with dementia and their family caregivers. We explored whether dementia-specific service needs and gaps could be predicted from simple information that can be readily acquired in routine medical care settings. Method Primary family caregivers for cognitively impaired older adults (n=215) were asked about current stress, challenging patient behaviors, and prior-year needs and gaps in 16 medical and psychosocial services. Demographic data, caregiver stress, and patient clinical features were evaluated in regression analyses to identify unique predictors of service needs and gaps. Results Caregiver stress and patient behavior problems together accounted for an average of 24% of the whole-sample variance in total needs and gaps. Across all analyses, including total, medical, and psychosocial services needs and gaps, all other variables combined (comorbid chronic disease, dementia severity, age, caregiver relationship, and residence) accounted for an accounted for a mean of 3%, with no variable yielding more than 4% in any equation. We combined stress and behavior problem indicators into a simple screen. In early/mild dementia dyads (n=111) typical in primary care settings, the screen identified gaps in total and psychosocial care in 84% and 77%, respectively, of those with high stress/high behavior problems vs. 25% and 23%, respectively, of those with low stress/low behavior problems. Medical care gaps were dramatically higher in high stress/high behavior problem dyads (66%) than all others (12%). Conclusion A simple tool (likely completed in 1–2 minutes) which combines caregiver stress and patient behavior problems, the Dementia Services Mini-Screen, could help clinicians rapidly identify high need, high gap dyads. Health care systems could use it to estimate population needs for targeted dementia services and facilitate their development. PMID:24315560
Rapid screening for inflammatory neuropathies by standardized clinical criteria
Tramontozzi, Louis A.
2016-01-01
Abstract Background: Delay in recognition and treatment of inflammatory neuropathies increases morbidity and mortality. We have developed and standardized 3 clinical screening criteria that rapidly detect inflammatory neuropathies. Methods: We reviewed all patients with definite large fiber neuropathy in 2 different patient populations: 1 from a private neurology clinic and the other from a tertiary care center. Patients were divided into 2 groups: those with an inflammatory neuropathy and those with a noninflammatory neuropathy. We specifically noted the 3 key neuropathy characteristics: onset, distribution, and associated systemic features (ODS). We studied the sensitivity and specificity of ODS in differentiating between inflammatory and noninflammatory neuropathies. Results: A total of 206 patients were included: 51 from the private clinic and 155 from the tertiary care center. The sensitivity of using ODS in detecting an inflammatory neuropathy was 96% and the specificity was 85%. The positive predictive value of ODS was 0.8 and negative predictive value was 0.97. Conclusions: Rapid screening for inflammatory neuropathies by ODS clinical criteria is highly sensitive and has a high negative predictive value for noninflammatory neuropathies. ODS uses simple clinical criteria to rapidly screen for patients with a potentially treatable form of neuropathy and accelerate their diagnostic evaluation. Classification of evidence: This study provides Class IV evidence that 3 neuropathy characteristics—onset, distribution, and associated systemic features—accurately identify patients with inflammatory neuropathies. PMID:29443273
Amanolahi, Farjad; Mohammadi, Ali; Kazemi Oskuee, Reza; Nassirli, Hooriyeh; Malaekeh-Nikouei, Bizhan
2017-01-01
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55, v/v, pH 3.5), C18 column (150 mm×4.6 mm×5 µm particle size) and a flow rate of 1 ml/min in ambient condition and total retention time of 17 min. The volume of injection was set at 20 µl and detection was recorded at 425 nm. The robustness of the method was examined by changing the mobile phase composition, mobile phase pH, and flow rate. Results: The method was validated with respect to precision, accuracy and linearity in a concentration range of 2-100 µg/ml. The limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.5 µg/ml, respectively. The percentage of recovery was 98.9 to 100.5 with relative standard deviation (RSD) < 0.638%. Conclusion: The method was found to be simple, sensitive and rapid for determination of curcumin in pharmaceutical samples and had enough sensitivity to detect degradation product of curcumin produced under photolysis and hydrolysis stress condition. PMID:29062806
Moroz, N A; Olvera, A; Willis, G M; Poudeu, P F P
2015-06-07
The use of template nanostructures for the creation of photovoltaic and thermoelectric semiconductors is becoming a quickly expanding synthesis strategy. In this work we report a simple two-step process enabling the formation of ternary CuAgSe nanoplatelets with a great degree of control over the composition and shape. Starting with hexagonal nanoplatelets of cubic Cu2-xSe, ternary CuAgSe nanoplatelets were generated through a rapid ion exchange reaction at 300 K using AgNO3 solution. The Cu2-xSe nanoplatelet template and the final CuAgSe nanoplatelets were analyzed by electron microscopy and X-ray diffraction (XRD). It was found that both the low temperature pseudotetragonal and the high temperature cubic forms of CuAgSe phase were created while maintaining the morphology of the Cu2-xSe nanoplatelet template. Thermal and electronic transport measurements of hot-pressed pellets of the synthesized CuAgSe nanoplatelets showed a drastic reduction in the thermal conductivity and a sharp transition from n-type (S = -45 μV K(-1)) to p-type (S = +200 μV K(-1)) semiconducting behavior upon heating above the structural transition from the low temperature orthorhombic to the high temperature super-ionic cubic phase. This simple reaction process utilizing a template nanostructure matrix represents an energy efficient, cost-efficient, and versatile strategy to create interesting materials with lower defect density and superior thermoelectric performance.
Yang, Qian; Manicke, Nicholas E.; Wang, He; Petucci, Christopher; Cooks, R. Graham
2013-01-01
A simple protocol for rapid quantitation of acylcarnitines in serum and whole blood has been developed using paper spray mass spectrometry. Dried serum and whole blood containing a mixture of ten acylcarnitines at various concentrations were analyzed as spots from paper directly without any sample pretreatment, separation, or derivatization. The composition of the spray solvent was found to be a critical factor: for serum samples, spray solvent of methanol/water/formic acid (80:20:0.1) gave the best signal intensity while for blood samples which contain more matrix components, acetonitrile/water (90:10) was a much more suitable spray solvent. For the paper type and size used, 0.5 μL of sample provided an optimal signal for both serum and whole blood samples. For quantitative profiling, the limits of quantitation obtained from both serum and blood were much lower than the clinically validated cutoff values for diagnosis of fatty acid oxidation disorders in newborn screening. Linearity (R2>0.95) and reproducibility (RSD ~10 %) were achieved in the concentration ranges from 100 nM to 5 μM for the C2 acylcarnitine, and for other acylcarnitines, these values were from 10 to 500 nM. Acylcarnitine profiles offer an effective demonstration of the fact that paper spray mass spectrometry is an appropriate, simple, rapid method with high sensitivity and high reproducibility applicable to newborn screening tests. PMID:22760507
Development of a simple, rapid, and robust intrathecal catheterization method in the rat.
Mazur, Curt; Fitzsimmons, Bethany; Kamme, Fredrik; Nichols, Brandon; Powers, Berit; Wancewicz, Ed
2017-03-15
The blood brain barrier (BBB) is an impediment to the development of large and highly charged molecules as therapeutics for diseases and injuries of the central nervous system (CNS). Antisense oligonucleotides (ASOs) are large (6000-8000MW) and highly charged and therefore do not cross the BBB. A method of circumventing the blood brain barrier to test ASOs, and other non-BBB penetrant molecules, as CNS therapeutics is the direct administration of these molecules to the CNS tissue or cerebral spinal fluid. We developed a rapid, simple and robust method for the intrathecal catheterization of rats to test putatively therapeutic antisense oligonucleotides. This method utilizes 23-gauge needles, simply constructed ½in. long 19-gauge guide cannulas and 8cm long plastic PE-10 sized catheters. Unlike the cisterna magna approach, this method uses a lumbar approach for intrathecal catheterization with the catheter residing entirely in the cauda equina space minimizing spinal cord compression. Readily available materials and only a few specialized pieces of equipment, which are easily manufactured, are used for this intrathecal catheterization method. This method is easy to learn and has been taught to multiple in house surgeons, collaborators and contract laboratories. Greater than 90% catheterization success is routinely achieved with this method and as many as 100 catheters can be placed and test substance administered in one 6-h period. This method has allowed the pre-clinical testing of hundreds of ASOs as therapeutics for CNS indications. Copyright © 2017 Elsevier B.V. All rights reserved.
Shrink-induced sorting using integrated nanoscale magnetic traps.
Nawarathna, Dharmakeerthi; Norouzi, Nazila; McLane, Jolie; Sharma, Himanshu; Sharac, Nicholas; Grant, Ted; Chen, Aaron; Strayer, Scott; Ragan, Regina; Khine, Michelle
2013-02-11
We present a plastic microfluidic device with integrated nanoscale magnetic traps (NSMTs) that separates magnetic from non-magnetic beads with high purity and throughput, and unprecedented enrichments. Numerical simulations indicate significantly higher localized magnetic field gradients than previously reported. We demonstrated >20 000-fold enrichment for 0.001% magnetic bead mixtures. Since we achieve high purity at all flow-rates tested, this is a robust, rapid, portable, and simple solution to sort target species from small volumes amenable for point-of-care applications. We used the NSMT in a 96 well format to extract DNA from small sample volumes for quantitative polymerase chain reaction (qPCR).
Karr, Dale B.; Waters, James K.; Emerich, David W.
1983-01-01
Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis. PMID:16346443
Han, Daehoon; Hong, Jinkee; Kim, Hyun Cheol; Sung, Jong Hwan; Lee, Jong Bum
2013-11-01
Many highly sensitive protein detection techniques have been developed and have played an important role in the analysis of proteins. Herein, we report a novel technique that can detect proteins sensitively and effectively using aptamer-based DNA nanostructures. Thrombin was used as a target protein and aptamer was used to capture fluorescent dye-labeled DNA nanobarcodes or thrombin on a microsphere. The captured DNA nanobarcodes were replaced by a thrombin and aptamer interaction. The detection ability of this approach was confirmed by flow cytometry with different concentrations of thrombin. Our detection method has great potential for rapid and simple protein detection with a variety of aptamers.
Laser-induced Forward Transfer of Ag Nanopaste.
Breckenfeld, Eric; Kim, Heungsoo; Auyeung, Raymond C Y; Piqué, Alberto
2016-03-31
Over the past decade, there has been much development of non-lithographic methods(1-3) for printing metallic inks or other functional materials. Many of these processes such as inkjet(3) and laser-induced forward transfer (LIFT)(4) have become increasingly popular as interest in printable electronics and maskless patterning has grown. These additive manufacturing processes are inexpensive, environmentally friendly, and well suited for rapid prototyping, when compared to more traditional semiconductor processing techniques. While most direct-write processes are confined to two-dimensional structures and cannot handle materials with high viscosity (particularly inkjet), LIFT can transcend both constraints if performed properly. Congruent transfer of three dimensional pixels (called voxels), also referred to as laser decal transfer (LDT)(5-9), has recently been demonstrated with the LIFT technique using highly viscous Ag nanopastes to fabricate freestanding interconnects, complex voxel shapes, and high-aspect-ratio structures. In this paper, we demonstrate a simple yet versatile process for fabricating a variety of micro- and macroscale Ag structures. Structures include simple shapes for patterning electrical contacts, bridging and cantilever structures, high-aspect-ratio structures, and single-shot, large area transfers using a commercial digital micromirror device (DMD) chip.
Laser-induced Forward Transfer of Ag Nanopaste
Breckenfeld, Eric; Kim, Heungsoo; Auyeung, Raymond C. Y.; Piqué, Alberto
2016-01-01
Over the past decade, there has been much development of non-lithographic methods1-3 for printing metallic inks or other functional materials. Many of these processes such as inkjet3 and laser-induced forward transfer (LIFT)4 have become increasingly popular as interest in printable electronics and maskless patterning has grown. These additive manufacturing processes are inexpensive, environmentally friendly, and well suited for rapid prototyping, when compared to more traditional semiconductor processing techniques. While most direct-write processes are confined to two-dimensional structures and cannot handle materials with high viscosity (particularly inkjet), LIFT can transcend both constraints if performed properly. Congruent transfer of three dimensional pixels (called voxels), also referred to as laser decal transfer (LDT)5-9, has recently been demonstrated with the LIFT technique using highly viscous Ag nanopastes to fabricate freestanding interconnects, complex voxel shapes, and high-aspect-ratio structures. In this paper, we demonstrate a simple yet versatile process for fabricating a variety of micro- and macroscale Ag structures. Structures include simple shapes for patterning electrical contacts, bridging and cantilever structures, high-aspect-ratio structures, and single-shot, large area transfers using a commercial digital micromirror device (DMD) chip. PMID:27077645
Lucantoni, Leonardo; Silvestrini, Francesco; Signore, Michele; Siciliano, Giulia; Eldering, Maarten; Dechering, Koen J.; Avery, Vicky M.; Alano, Pietro
2015-01-01
Plasmodium falciparum gametocytes, specifically the mature stages, are the only malaria parasite stage in humans transmissible to the mosquito vector. Anti-malarial drugs capable of killing these forms are considered essential for the eradication of malaria and tools allowing the screening of large compound libraries with high predictive power are needed to identify new candidates. As gametocytes are not a replicative stage it is difficult to apply the same drug screening methods used for asexual stages. Here we propose an assay, based on high content imaging, combining “classic” gametocyte viability readout based on gametocyte counts with a functional viability readout, based on gametocyte activation and the discrimination of the typical gamete spherical morphology. This simple and rapid assay has been miniaturized to a 384-well format using acridine orange staining of wild type P. falciparum 3D7A sexual forms, and was validated by screening reference antimalarial drugs and the MMV Malaria Box. The assay demonstrated excellent robustness and ability to identify quality hits with high likelihood of confirmation of transmission reducing activity in subsequent mosquito membrane feeding assays. PMID:26553647
Yi, Gihwan; Choi, Jun-Ho; Lee, Jong-Hee; Jeong, Unggi; Nam, Min-Hee; Yun, Doh-Won; Eun, Moo-Young
2005-01-01
We describe a rapid and simple procedure for homogenizing leaf samples suitable for mini/midi-scale DNA preparation in rice. The methods used tungsten carbide beads and general vortexer for homogenizing leaf samples. In general, two samples can be ground completely within 11.3+/-1.5 sec at one time. Up to 20 samples can be ground at a time using a vortexer attachment. The yields of the DNA ranged from 2.2 to 7.6 microg from 25-150 mg of young fresh leaf tissue. The quality and quantity of DNA was compatible for most of PCR work and RFLP analysis.
NASA Astrophysics Data System (ADS)
Yue, Xiao-li; Wang, Zhao-qing; Li, Chao-rui; Yang, Zheng-yin
2018-03-01
In this paper, a simple naphthalene-based derivative (HL) has been designed and synthesized as a Al3 +-selective fluorescent chemosensor based on the PET mechanism. HL exhibited high selectivity and sensitivity towards Al3 + over other commonly coexisting metal ions in ethanol with a detection limit of 2.72 nM. The 1:1 binding stoichiometry of the complex (HL-Al3 +) was determined from the Job's plot based on fluorescence titrations and the ESI-MS spectrum data. Moreover, the binding site of HL with Al3 + was assured by the 1H NMR titration experiment. The binding constant (Ka) of the complex (HL-Al3 +) was calculated to be 5.06 × 104 M- 1 according to the Benesi-Hildebrand equation. In addition, the recognizing process of HL towards Al3 + was chemically reversible by adding Na2EDTA. Importantly, HL could directly and rapidly detect aluminum ion through the filter paper without resorting to additional instrumental analysis.
Baym, Michael; Shaket, Lev; Anzai, Isao A; Adesina, Oluwakemi; Barstow, Buz
2016-11-10
Whole-genome knockout collections are invaluable for connecting gene sequence to function, yet traditionally, their construction has required an extraordinary technical effort. Here we report a method for the construction and purification of a curated whole-genome collection of single-gene transposon disruption mutants termed Knockout Sudoku. Using simple combinatorial pooling, a highly oversampled collection of mutants is condensed into a next-generation sequencing library in a single day, a 30- to 100-fold improvement over prior methods. The identities of the mutants in the collection are then solved by a probabilistic algorithm that uses internal self-consistency within the sequencing data set, followed by rapid algorithmically guided condensation to a minimal representative set of mutants, validation, and curation. Starting from a progenitor collection of 39,918 mutants, we compile a quality-controlled knockout collection of the electroactive microbe Shewanella oneidensis MR-1 containing representatives for 3,667 genes that is functionally validated by high-throughput kinetic measurements of quinone reduction.
Rapid and efficient method to extract metagenomic DNA from estuarine sediments.
Shamim, Kashif; Sharma, Jaya; Dubey, Santosh Kumar
2017-07-01
Metagenomic DNA from sediments of selective estuaries of Goa, India was extracted using a simple, fast, efficient and environment friendly method. The recovery of pure metagenomic DNA from our method was significantly high as compared to other well-known methods since the concentration of recovered metagenomic DNA ranged from 1185.1 to 4579.7 µg/g of sediment. The purity of metagenomic DNA was also considerably high as the ratio of absorbance at 260 and 280 nm ranged from 1.88 to 1.94. Therefore, the recovered metagenomic DNA was directly used to perform various molecular biology experiments viz. restriction digestion, PCR amplification, cloning and metagenomic library construction. This clearly proved that our protocol for metagenomic DNA extraction using silica gel efficiently removed the contaminants and prevented shearing of the metagenomic DNA. Thus, this modified method can be used to recover pure metagenomic DNA from various estuarine sediments in a rapid, efficient and eco-friendly manner.
Murphy, Ryan P; Kelley, Elizabeth G; Rogers, Simon A; Sullivan, Millicent O; Epps, Thomas H
2014-11-18
Chain exchange between block polymer micelles in highly selective solvents, such as water, is well-known to be arrested under quiescent conditions, yet this work demonstrates that simple agitation methods can induce rapid chain exchange in these solvents. Aqueous solutions containing either pure poly(butadiene- b -ethylene oxide) or pure poly(butadiene- b -ethylene oxide- d 4 ) micelles were combined and then subjected to agitation by vortex mixing, concentric cylinder Couette flow, or nitrogen gas sparging. Subsequently, the extent of chain exchange between micelles was quantified using small angle neutron scattering. Rapid vortex mixing induced chain exchange within minutes, as evidenced by a monotonic decrease in scattered intensity, whereas Couette flow and sparging did not lead to measurable chain exchange over the examined time scale of hours. The linear kinetics with respect to agitation time suggested a surface-limited exchange process at the air-water interface. These findings demonstrate the strong influence of processing conditions on block polymer solution assemblies.
Simple colorimetric detection of doxycycline and oxytetracycline using unmodified gold nanoparticles
NASA Astrophysics Data System (ADS)
Li, Jie; Fan, Shumin; Li, Zhigang; Xie, Yuanzhe; Wang, Rui; Ge, Baoyu; Wu, Jing; Wang, Ruiyong
2014-08-01
The interaction between tetracycline antibiotics and gold nanoparticles was studied. With citrate-coated gold nanoparticles as colorimetric probe, a simple and rapid detection method for doxycycline and oxytetracycline has been developed. This method relies on the distance-dependent optical properties of gold nanoparticles. In weakly acidic buffer medium, doxycycline and oxytetracycline could rapidly induce the aggregation of gold nanoparticles, resulting in red-to-blue (or purple) colour change. The experimental parameters were optimized with regard to pH, the concentration of the gold nanoparticles and the reaction time. Under optimal experimental conditions, the linear range of the colorimetric sensor for doxycycline/oxytetracycline was 0.06-0.66 and 0.59-8.85 μg mL-1, respectively. The corresponding limit of detection for doxycycline and oxytetracycline was 0.0086 and 0.0838 μg mL-1, respectively. This assay was sensitive, selective, simple and readily used to detect tetracycline antibiotics in food products.
Probing the Boundaries of Orthology: The Unanticipated Rapid Evolution of Drosophila centrosomin
Eisman, Robert C.; Kaufman, Thomas C.
2013-01-01
The rapid evolution of essential developmental genes and their protein products is both intriguing and problematic. The rapid evolution of gene products with simple protein folds and a lack of well-characterized functional domains typically result in a low discovery rate of orthologous genes. Additionally, in the absence of orthologs it is difficult to study the processes and mechanisms underlying rapid evolution. In this study, we have investigated the rapid evolution of centrosomin (cnn), an essential gene encoding centrosomal protein isoforms required during syncytial development in Drosophila melanogaster. Until recently the rapid divergence of cnn made identification of orthologs difficult and questionable because Cnn violates many of the assumptions underlying models for protein evolution. To overcome these limitations, we have identified a group of insect orthologs and present conserved features likely to be required for the functions attributed to cnn in D. melanogaster. We also show that the rapid divergence of Cnn isoforms is apparently due to frequent coding sequence indels and an accelerated rate of intronic additions and eliminations. These changes appear to be buffered by multi-exon and multi-reading frame maximum potential ORFs, simple protein folds, and the splicing machinery. These buffering features also occur in other genes in Drosophila and may help prevent potentially deleterious mutations due to indels in genes with large coding exons and exon-dense regions separated by small introns. This work promises to be useful for future investigations of cnn and potentially other rapidly evolving genes and proteins. PMID:23749319
The Internal Ballistics of an Air Gun
NASA Astrophysics Data System (ADS)
Denny, Mark
2011-02-01
The internal ballistics of a firearm or artillery piece considers the pellet, bullet, or shell motion while it is still inside the barrel. In general, deriving the muzzle speed of a gunpowder firearm from first principles is difficult because powder combustion is fast and it very rapidly raises the temperature of gas (generated by gunpowder deflagration, or burning), which greatly complicates the analysis. A simple case is provided by air guns, for which we can make reasonable approximations that permit a derivation of muzzle speed. It is perhaps surprising that muzzle speed depends upon barrel length (artillerymen debated this dependence for centuries, until it was established experimentally and, later, theoretically ). Here we see that a simple physical analysis, accessible to high school or freshmen undergraduate physics students, not only derives realistic muzzle speed but also shows how it depends upon barrel length.
The Doppler Pendulum Experiment
ERIC Educational Resources Information Center
Lee, C. K.; Wong, H. K.
2011-01-01
An experiment to verify the Doppler effect of sound waves is described. An ultrasonic source is mounted at the end of a simple pendulum. As the pendulum swings, the rapid change of frequency can be recorded by a stationary receiver using a simple frequency-to-voltage converter. The experimental results are in close agreement with the Doppler…
Quantitation & Case-Study-Driven Inquiry to Enhance Yeast Fermentation Studies
ERIC Educational Resources Information Center
Grammer, Robert T.
2012-01-01
We propose a procedure for the assay of fermentation in yeast in microcentrifuge tubes that is simple and rapid, permitting assay replicates, descriptive statistics, and the preparation of line graphs that indicate reproducibility. Using regression and simple derivatives to determine initial velocities, we suggest methods to compare the effects of…
A simple and rapid radiochemical choline acetyltransferase (ChAT) assay screening test.
Shiba, Kazuhiro; Ogawa, Kazuma; Kinuya, Seigo; Yajima, Kazuyoshi; Mori, Hirofumi
2006-10-15
A simple radiochemical choline acetyltransferase (ChAT) assay screening test was developed by measuring for [(3)H]acetylcholine ([(3)H]ACh) formed from 0.2 mM [(3)H]acetyl-coenzyme A ([(3)H]acetyl-CoA) and 1 mM choline by 0.2 mg of rat brain homogenates containing ChAT into 96-well microplates. A simple and rapid procedure for isolating [(3)H]ACh from the incubation mixture into 96-well microplates was achieved by using a sodium tetraphenylboron (Kalibor) solution (in ethyl acetate, 0.75%, w/v) and a hydrophobic liquid scintillator mixture (1:5, v/v, 0.2 mL) as an extraction solvent. The benefits of this radiochemical method using 96-well microplates are as follows: (1) this method is reliable and reproducible; (2) many samples can be examined at the same time by this method; (3) this method is economical and effective in reducing radioactive waste. The development of a new simple radiochemical ChAT assay screening test is the first stage of development of radiolabeled ChAT mapping agent.
Design Principles for Rapid Prototyping Forces Sensors using 3D Printing.
Kesner, Samuel B; Howe, Robert D
2011-07-21
Force sensors provide critical information for robot manipulators, manufacturing processes, and haptic interfaces. Commercial force sensors, however, are generally not adapted to specific system requirements, resulting in sensors with excess size, cost, and fragility. To overcome these issues, 3D printers can be used to create components for the quick and inexpensive development of force sensors. Limitations of this rapid prototyping technology, however, require specialized design principles. In this paper, we discuss techniques for rapidly developing simple force sensors, including selecting and attaching metal flexures, using inexpensive and simple displacement transducers, and 3D printing features to aid in assembly. These design methods are illustrated through the design and fabrication of a miniature force sensor for the tip of a robotic catheter system. The resulting force sensor prototype can measure forces with an accuracy of as low as 2% of the 10 N measurement range.
Simple, Rapid, and Selective Isolation of 2S Albumins from Allergenic Seeds and Nuts.
Hummel, Marlene; Wigger, Tina; Höper, Tessa; Westkamp, Imke; Brockmeyer, Jens
2015-07-08
The 2S albumins belong to the group of seed storage proteins present in different seeds and nuts. Due to their pronounced allergenic potential, which is often associated with severe allergic reactions, this protein family is of special interest in the field of allergen research. Here we present a simple, rapid, and selective method for the purification of 2S albumins directly from allergenic seeds and nuts. We systematically optimized the parameters "buffer system", "extraction temperature", "buffer molarity", and "pH " and were able to achieve 2S albumin purities of about 99% without further purification and demonstrate transferability of this method to nine different allergenic food matrices. Compared to conventional isolation routines, significant reduction of hands-on time and required laboratory equipment is achieved, but nonetheless higher protein yields are obtained. The presented method allows for the rapid purification of different 2S albumins including the corresponding isoforms from natural material.
The picture exchange communication system.
Bondy, A S; Frost, L A
1998-01-01
The Picture Exchange Communication System (PECS) was developed as a means to teach children with autism and related developmental disabilities a rapidly acquired, self-initiating, functional communication system. Its theoretical roots combine principles from applied behavior analysis and guidelines established within the field of alternative and augmentative communication. This approach has several potential advantages relative to imitation-based strategies (both vocal and gestural) and symbol selection strategies. The system begins with the exchange of simple icons but rapidly builds "sentence" structure. The system also emphasizes developing the request function prior to developing responding to simple questions and commenting. The development of requesting with a sentence structure also permits the rapid development of attributes more traditionally taught within a receptive mode. The relationship between the introduction of PECS and various other behavioral issues (i.e., social approach and behavior management) as well as its relationship to the codevelopment of speech are reviewed.
Pallapothu, Leela Mohan Kumar; Batta, Neelima; Pigili, Ravi Kumar; Yejella, Rajendra Prasad
2015-02-01
A simple, rapid and sensitive analytical method using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) detection with positive ion electrospray ionization was developed for the determination of dienogest in human K2 EDTA plasma using levonorgestrel d6 as an internal standard (IS). Dienogest and IS were extracted from human plasma using simple liquid-liquid extraction. Chromatographic separation was achieved on a Zorbax XDB-Phenyl column (4.6 × 75 mm, 3.5 µm) under isocratic conditions using acetonitrile-5 mm ammonium acetate (70:30, v/v) at a flow rate of 0.60 mL/min. The protonated precursor to product ion transitions monitored for dienogest and IS were at m/z 312.30 → 135.30 and 319.00 → 251.30, respectively. The method was validated with a linearity range of 1.003-200.896 ng/mL having a total analysis time for each chromatograph of 3.0 min. The method has shown tremendous reproducibility with intra- and inter-day precision (coefficient of variation) <3.97 and 6.10%, respectively, and accuracy within ±4.0% of nominal values. The validated method was applied to a pharmacokinetic study in human plasma samples generated after administration of a single oral dose of 2.0 mg dienogest tablets to healthy female volunteers and was proved to be highly reliable for the analysis of clinical samples. Copyright © 2014 John Wiley & Sons, Ltd.
Temporal Precision of Neuronal Information in a Rapid Perceptual Judgment
Ghose, Geoffrey M.; Harrison, Ian T.
2009-01-01
In many situations, such as pedestrians crossing a busy street or prey evading predators, rapid decisions based on limited perceptual information are critical for survival. The brevity of these perceptual judgments constrains how neuronal signals are integrated or pooled over time because the underlying sequence of processes, from sensation to perceptual evaluation to motor planning and execution, all occur within several hundred milliseconds. Because most previous physiological studies of these processes have relied on tasks requiring considerably longer temporal integration, the neuronal basis of such rapid decisions remains largely unexplored. In this study, we examine the temporal precision of neuronal activity associated with a rapid perceptual judgment. We find that the activity of individual neurons over tens of milliseconds can reliably convey information about sensory events and was well correlated with the animals' judgments. There was a strong correlation between sensory reliability and the correlation with behavioral choice, suggesting that rapid decisions were preferentially based on the most reliable sensory signals. We also find that a simple model in which the responses of a small number of individual neurons (<5) are summed can completely explain behavioral performance. These results suggest that neuronal circuits are sufficiently precise to allow for cognitive decisions to be based on small numbers of action potentials from highly reliable neurons. PMID:19109454
Temporal precision of neuronal information in a rapid perceptual judgment.
Ghose, Geoffrey M; Harrison, Ian T
2009-03-01
In many situations, such as pedestrians crossing a busy street or prey evading predators, rapid decisions based on limited perceptual information are critical for survival. The brevity of these perceptual judgments constrains how neuronal signals are integrated or pooled over time because the underlying sequence of processes, from sensation to perceptual evaluation to motor planning and execution, all occur within several hundred milliseconds. Because most previous physiological studies of these processes have relied on tasks requiring considerably longer temporal integration, the neuronal basis of such rapid decisions remains largely unexplored. In this study, we examine the temporal precision of neuronal activity associated with a rapid perceptual judgment. We find that the activity of individual neurons over tens of milliseconds can reliably convey information about sensory events and was well correlated with the animals' judgments. There was a strong correlation between sensory reliability and the correlation with behavioral choice, suggesting that rapid decisions were preferentially based on the most reliable sensory signals. We also find that a simple model in which the responses of a small number of individual neurons (<5) are summed can completely explain behavioral performance. These results suggest that neuronal circuits are sufficiently precise to allow for cognitive decisions to be based on small numbers of action potentials from highly reliable neurons.
A rapid mechanism to remobilize and homogenize highly crystalline magma bodies.
Burgisser, Alain; Bergantz, George W
2011-03-10
The largest products of magmatic activity on Earth, the great bodies of granite and their corresponding large eruptions, have a dual nature: homogeneity at the large scale and spatial and temporal heterogeneity at the small scale. This duality calls for a mechanism that selectively removes the large-scale heterogeneities associated with the incremental assembly of these magmatic systems and yet occurs rapidly despite crystal-rich, viscous conditions seemingly resistant to mixing. Here we show that a simple dynamic template can unify a wide range of apparently contradictory observations from both large plutonic bodies and volcanic systems by a mechanism of rapid remobilization (unzipping) of highly viscous crystal-rich mushes. We demonstrate that this remobilization can lead to rapid overturn and produce the observed juxtaposition of magmatic materials with very disparate ages and complex chemical zoning. What distinguishes our model is the recognition that the process has two stages. Initially, a stiff mushy magma is reheated from below, producing a reduction in crystallinity that leads to the growth of a subjacent buoyant mobile layer. When the thickening mobile layer becomes sufficiently buoyant, it penetrates the overlying viscous mushy magma. This second stage rapidly exports homogenized material from the lower mobile layer to the top of the system, and leads to partial overturn within the viscous mush itself as an additional mechanism of mixing. Model outputs illustrate that unzipping can rapidly produce large amounts of mobile magma available for eruption. The agreement between calculated and observed unzipping rates for historical eruptions at Pinatubo and at Montserrat demonstrates the general applicability of the model. This mechanism furthers our understanding of both the formation of periodically homogenized plutons (crust building) and of ignimbrites by large eruptions.
Holey graphene frameworks for highly selective post-combustion carbon capture
Chowdhury, Shamik; Balasubramanian, Rajasekhar
2016-01-01
Atmospheric CO2 concentrations continue to rise rapidly in response to increased combustion of fossil fuels, contributing to global climate change. In order to mitigate the effects of global warming, development of new materials for cost-effective and energy-efficient CO2 capture is critically important. Graphene-based porous materials are an emerging class of solid adsorbents for selectively removing CO2 from flue gases. Herein, we report a simple and scalable approach to produce three-dimensional holey graphene frameworks with tunable porosity and pore geometry, and demonstrate their application as high-performance CO2 adsorbents. These holey graphene macrostructures exhibit a significantly improved specific surface area and pore volume compared to their pristine counterparts, and can be effectively used in post-combustion CO2 adsorption systems because of their intrinsic hydrophobicity together with good gravimetric storage capacities, rapid removal capabilities, superior cycling stabilities, and moderate initial isosteric heats. In addition, an exceptionally high CO2 over N2 selectivity can be achieved under conditions relevant to capture from the dry exhaust gas stream of a coal burning power plant, suggesting the possibility of recovering highly pure CO2 for long-term sequestration and/or utilization for downstream applications. PMID:26879393
Guo, Yufei; Li, Jing; Yuan, Yupeng; Li, Lu; Zhang, Mingyi; Zhou, Chenyan; Lin, Zhiqun
2016-11-14
Highly crystalline graphitic carbon nitride (g-C 3 N 4 ) with decreased structural imperfections benefits from the suppression of electron-hole recombination, which enhances its hydrogen generation activity. However, producing such g-C 3 N 4 materials by conventional heating in an electric furnace has proven challenging. Herein, we report on the synthesis of high-quality g-C 3 N 4 with reduced structural defects by judiciously combining the implementation of melamine-cyanuric acid (MCA) supramolecular aggregates and microwave-assisted thermolysis. The g-C 3 N 4 material produced after optimizing the microwave reaction time can effectively generate H 2 under visible-light irradiation. The highest H 2 evolution rate achieved was 40.5 μmol h -1 , which is two times higher than that of a g-C 3 N 4 sample prepared by thermal polycondensation of the same supramolecular aggregates in an electric furnace. The microwave-assisted thermolysis strategy is simple, rapid, and robust, thereby providing a promising route for the synthesis of high-efficiency g-C 3 N 4 photocatalysts. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Holey graphene frameworks for highly selective post-combustion carbon capture.
Chowdhury, Shamik; Balasubramanian, Rajasekhar
2016-02-16
Atmospheric CO2 concentrations continue to rise rapidly in response to increased combustion of fossil fuels, contributing to global climate change. In order to mitigate the effects of global warming, development of new materials for cost-effective and energy-efficient CO2 capture is critically important. Graphene-based porous materials are an emerging class of solid adsorbents for selectively removing CO2 from flue gases. Herein, we report a simple and scalable approach to produce three-dimensional holey graphene frameworks with tunable porosity and pore geometry, and demonstrate their application as high-performance CO2 adsorbents. These holey graphene macrostructures exhibit a significantly improved specific surface area and pore volume compared to their pristine counterparts, and can be effectively used in post-combustion CO2 adsorption systems because of their intrinsic hydrophobicity together with good gravimetric storage capacities, rapid removal capabilities, superior cycling stabilities, and moderate initial isosteric heats. In addition, an exceptionally high CO2 over N2 selectivity can be achieved under conditions relevant to capture from the dry exhaust gas stream of a coal burning power plant, suggesting the possibility of recovering highly pure CO2 for long-term sequestration and/or utilization for downstream applications.
Dark-ages reionization and galaxy formation simulation - IX. Economics of reionizing galaxies
NASA Astrophysics Data System (ADS)
Duffy, Alan R.; Mutch, Simon J.; Poole, Gregory B.; Geil, Paul M.; Kim, Han-Seek; Mesinger, Andrei; Wyithe, J. Stuart B.
2017-09-01
Using a series of high-resolution hydrodynamical simulations we show that during the rapid growth of high-redshift (z > 5) galaxies, reserves of molecular gas are consumed over a time-scale of 300 Myr, almost independent of feedback scheme. We find that there exists no such simple relation for the total gas fractions of these galaxies, with little correlation between gas fractions and specific star formation rates. The bottleneck or limiting factor in the growth of early galaxies is in converting infalling gas to cold star-forming gas. Thus, we find that the majority of high-redshift dwarf galaxies are effectively in recession, with demand (of star formation) never rising to meet supply (of gas), irrespective of the baryonic feedback physics modelled. We conclude that the basic assumption of self-regulation in galaxies - that they can adjust total gas consumption within a Hubble time - does not apply for the dwarf galaxies thought to be responsible for providing most UV photons to reionize the high-redshift Universe. We demonstrate how this rapid molecular time-scale improves agreement between semi-analytic model predictions of the early Universe and observed stellar mass functions.
Holey graphene frameworks for highly selective post-combustion carbon capture
NASA Astrophysics Data System (ADS)
Chowdhury, Shamik; Balasubramanian, Rajasekhar
2016-02-01
Atmospheric CO2 concentrations continue to rise rapidly in response to increased combustion of fossil fuels, contributing to global climate change. In order to mitigate the effects of global warming, development of new materials for cost-effective and energy-efficient CO2 capture is critically important. Graphene-based porous materials are an emerging class of solid adsorbents for selectively removing CO2 from flue gases. Herein, we report a simple and scalable approach to produce three-dimensional holey graphene frameworks with tunable porosity and pore geometry, and demonstrate their application as high-performance CO2 adsorbents. These holey graphene macrostructures exhibit a significantly improved specific surface area and pore volume compared to their pristine counterparts, and can be effectively used in post-combustion CO2 adsorption systems because of their intrinsic hydrophobicity together with good gravimetric storage capacities, rapid removal capabilities, superior cycling stabilities, and moderate initial isosteric heats. In addition, an exceptionally high CO2 over N2 selectivity can be achieved under conditions relevant to capture from the dry exhaust gas stream of a coal burning power plant, suggesting the possibility of recovering highly pure CO2 for long-term sequestration and/or utilization for downstream applications.
NASA Astrophysics Data System (ADS)
Moroz, N. A.; Olvera, A.; Willis, G. M.; Poudeu, P. F. P.
2015-05-01
The use of template nanostructures for the creation of photovoltaic and thermoelectric semiconductors is becoming a quickly expanding synthesis strategy. In this work we report a simple two-step process enabling the formation of ternary CuAgSe nanoplatelets with a great degree of control over the composition and shape. Starting with hexagonal nanoplatelets of cubic Cu2-xSe, ternary CuAgSe nanoplatelets were generated through a rapid ion exchange reaction at 300 K using AgNO3 solution. The Cu2-xSe nanoplatelet template and the final CuAgSe nanoplatelets were analyzed by electron microscopy and X-ray diffraction (XRD). It was found that both the low temperature pseudotetragonal and the high temperature cubic forms of CuAgSe phase were created while maintaining the morphology of the Cu2-xSe nanoplatelet template. Thermal and electronic transport measurements of hot-pressed pellets of the synthesized CuAgSe nanoplatelets showed a drastic reduction in the thermal conductivity and a sharp transition from n-type (S = -45 μV K-1) to p-type (S = +200 μV K-1) semiconducting behavior upon heating above the structural transition from the low temperature orthorhombic to the high temperature super-ionic cubic phase. This simple reaction process utilizing a template nanostructure matrix represents an energy efficient, cost-efficient, and versatile strategy to create interesting materials with lower defect density and superior thermoelectric performance.The use of template nanostructures for the creation of photovoltaic and thermoelectric semiconductors is becoming a quickly expanding synthesis strategy. In this work we report a simple two-step process enabling the formation of ternary CuAgSe nanoplatelets with a great degree of control over the composition and shape. Starting with hexagonal nanoplatelets of cubic Cu2-xSe, ternary CuAgSe nanoplatelets were generated through a rapid ion exchange reaction at 300 K using AgNO3 solution. The Cu2-xSe nanoplatelet template and the final CuAgSe nanoplatelets were analyzed by electron microscopy and X-ray diffraction (XRD). It was found that both the low temperature pseudotetragonal and the high temperature cubic forms of CuAgSe phase were created while maintaining the morphology of the Cu2-xSe nanoplatelet template. Thermal and electronic transport measurements of hot-pressed pellets of the synthesized CuAgSe nanoplatelets showed a drastic reduction in the thermal conductivity and a sharp transition from n-type (S = -45 μV K-1) to p-type (S = +200 μV K-1) semiconducting behavior upon heating above the structural transition from the low temperature orthorhombic to the high temperature super-ionic cubic phase. This simple reaction process utilizing a template nanostructure matrix represents an energy efficient, cost-efficient, and versatile strategy to create interesting materials with lower defect density and superior thermoelectric performance. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr01451d
High-Content Optical Codes for Protecting Rapid Diagnostic Tests from Counterfeiting.
Gökçe, Onur; Mercandetti, Cristina; Delamarche, Emmanuel
2018-06-19
Warnings and reports on counterfeit diagnostic devices are released several times a year by regulators and public health agencies. Unfortunately, mishandling, altering, and counterfeiting point-of-care diagnostics (POCDs) and rapid diagnostic tests (RDTs) is lucrative, relatively simple and can lead to devastating consequences. Here, we demonstrate how to implement optical security codes in silicon- and nitrocellulose-based flow paths for device authentication using a smartphone. The codes are created by inkjet spotting inks directly on nitrocellulose or on micropillars. Codes containing up to 32 elements per mm 2 and 8 colors can encode as many as 10 45 combinations. Codes on silicon micropillars can be erased by setting a continuous flow path across the entire array of code elements or for nitrocellulose by simply wicking a liquid across the code. Static or labile code elements can further be formed on nitrocellulose to create a hidden code using poly(ethylene glycol) (PEG) or glycerol additives to the inks. More advanced codes having a specific deletion sequence can also be created in silicon microfluidic devices using an array of passive routing nodes, which activate in a particular, programmable sequence. Such codes are simple to fabricate, easy to view, and efficient in coding information; they can be ideally used in combination with information on a package to protect diagnostic devices from counterfeiting.
Martella, Andrea; Matjusaitis, Mantas; Auxillos, Jamie; Pollard, Steven M; Cai, Yizhi
2017-07-21
Mammalian plasmid expression vectors are critical reagents underpinning many facets of research across biology, biomedical research, and the biotechnology industry. Traditional cloning methods often require laborious manual design and assembly of plasmids using tailored sequential cloning steps. This process can be protracted, complicated, expensive, and error-prone. New tools and strategies that facilitate the efficient design and production of bespoke vectors would help relieve a current bottleneck for researchers. To address this, we have developed an extensible mammalian modular assembly kit (EMMA). This enables rapid and efficient modular assembly of mammalian expression vectors in a one-tube, one-step golden-gate cloning reaction, using a standardized library of compatible genetic parts. The high modularity, flexibility, and extensibility of EMMA provide a simple method for the production of functionally diverse mammalian expression vectors. We demonstrate the value of this toolkit by constructing and validating a range of representative vectors, such as transient and stable expression vectors (transposon based vectors), targeting vectors, inducible systems, polycistronic expression cassettes, fusion proteins, and fluorescent reporters. The method also supports simple assembly combinatorial libraries and hierarchical assembly for production of larger multigenetic cargos. In summary, EMMA is compatible with automated production, and novel genetic parts can be easily incorporated, providing new opportunities for mammalian synthetic biology.
Lee, Myung-Jae; Lee, Heon-Woo; Kang, Jong-Min; Seo, Ji-Hyung; Tak, Seong-Kun; Shim, Wangseob; Yim, Sung-Vin; Hong, Seung Jae; Lee, Kyung-Tae
2010-10-01
We describe a simple, rapid and sensitive high-performance liquid chromatography-electrospray ionization tandem mass spectrometric method that was developed for the simultaneous determination of carebastine and pseudoephedrine in human plasma using cisapride as an internal standard. Acquisition was performed in multiple-reaction monitoring mode by monitoring the transitions: m/z 500.43 > 167.09 for carebastine and m/z 166.04 > 147.88 for pseudoephedrine. The devised method involves a simple single-step liquid-liquid extraction with ethyl acetate. Chromatographic separation was performed on a C(18) reversed-phase chromatographic column at 0.2 mL/min by isocratic elution with 10 mM ammonium formate buffer-acetonitrile (30:70, v/v; adjusted to pH 3.3 with formic acid). The devised method was validated over 0.5-100 ng/mL of carebastine and 5-1000 ng/mL of pseudoephedrine with acceptable accuracy and precision, and was successfully applied to a bioequivalence study involving a single oral dose (10 mg of ebastine plus 120 mg of pseudoephedrine complex) to healthy Korean volunteers. Copyright © 2010 John Wiley & Sons, Ltd.
A Simple PCR Method for Rapid Genotype Analysis of Mycobacterium ulcerans
Stinear, Timothy; Davies, John K.; Jenkin, Grant A.; Portaels, Françoise; Ross, Bruce C.; OppEdIsano, Frances; Purcell, Maria; Hayman, John A.; Johnson, Paul D. R.
2000-01-01
Two high-copy-number insertion sequences, IS2404 and IS2606, were recently identified in Mycobacterium ulcerans and were shown by Southern hybridization to possess restriction fragment length polymorphism between strains from different geographic origins. We have designed a simple genotyping method that captures these differences by PCR amplification of the region between adjacent copies of IS2404 and IS2606. We have called this system 2426 PCR. The method is rapid, reproducible, sensitive, and specific for M. ulcerans, and it has confirmed previous studies suggesting a clonal population structure of M. ulcerans within a geographic region. M. ulcerans isolates from Australia, Papua New Guinea, Malaysia, Surinam, Mexico, Japan, China, and several countries in Africa were easily differentiated based on an array of 4 to 14 PCR products ranging in size from 200 to 900 bp. Numerical analysis of the banding patterns suggested a close evolutionary link between M. ulcerans isolates from Africa and southeast Asia. The application of 2426 PCR to total DNA, extracted directly from M. ulcerans-infected tissue specimens without culture, demonstrated the sensitivity and specificity of this method and confirmed for the first time that both animal and human isolates from areas of endemicity in southeast Australia have the same genotype. PMID:10747130
An improved ternary vector system for Agrobacterium-mediated rapid maize transformation.
Anand, Ajith; Bass, Steven H; Wu, Emily; Wang, Ning; McBride, Kevin E; Annaluru, Narayana; Miller, Michael; Hua, Mo; Jones, Todd J
2018-05-01
A simple and versatile ternary vector system that utilizes improved accessory plasmids for rapid maize transformation is described. This system facilitates high-throughput vector construction and plant transformation. The super binary plasmid pSB1 is a mainstay of maize transformation. However, the large size of the base vector makes it challenging to clone, the process of co-integration is cumbersome and inefficient, and some Agrobacterium strains are known to give rise to spontaneous mutants resistant to tetracycline. These limitations present substantial barriers to high throughput vector construction. Here we describe a smaller, simpler and versatile ternary vector system for maize transformation that utilizes improved accessory plasmids requiring no co-integration step. In addition, the newly described accessory plasmids have restored virulence genes found to be defective in pSB1, as well as added virulence genes. Testing of different configurations of the accessory plasmids in combination with T-DNA binary vector as ternary vectors nearly doubles both the raw transformation frequency and the number of transformation events of usable quality in difficult-to-transform maize inbreds. The newly described ternary vectors enabled the development of a rapid maize transformation method for elite inbreds. This vector system facilitated screening different origins of replication on the accessory plasmid and T-DNA vector, and four combinations were identified that have high (86-103%) raw transformation frequency in an elite maize inbred.
Eisenstein, Edward M.; Eisenstein, Doris L.; Sarma, Jonnalagedda Sarma M.; Knapp, Herschel; Smith, James C.
2012-01-01
This paper explores further the “behavioral homeostasis theory” (BHT) regarding the evolutionary significance for organism survival of the two simple non-associative rapidly learned behaviors of habituation and sensitization. The BHT postulates that the evolutionary function of habituation and sensitization throughout phylogeny is to rapidly maximize an organism’s overall readiness to cope with new stimuli and to minimize unnecessary energy expenditure. These behaviors have survived with remarkable similarity throughout phylogeny from aneural protozoa to humans. The concept of “behavioral homeostasis” emphasizes that the homeostatic process is more than just maintaining internal equilibrium in the face of changing internal and external conditions. It emphasizes the rapid internal and external effector system changes that occur to optimize organism readiness to cope with any new external stimulus situation. Truly life-threatening stimuli elicit instinctive behavior such as fight, flee, or hide. If the stimulus is not life-threatening, the organism rapidly learns to adjust to an appropriate level of overall responsiveness over stimulus repetitions. The rapid asymptotic level approached by those who decrease their overall responsiveness to the second stimulus (habituaters) and those who increase their overall responsiveness to an identical second stimulus (sensitizers) not only optimizes readiness to cope with any new stimulus situation but also reduces unnecessary energy expenditure. This paper is based on a retrospective analysis of data from 4 effector system responses to eight repetitive tone stimuli in adult human males. The effector systems include the galvanic skin response, finger pulse volume, muscle frontalis and heart rate. The new information provides the basis for further exploration of the BHT including new predictions and proposed relatively simple experiments to test them. PMID:22896782
A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt
Carol A. Clausen; Vina W. Yang
2011-01-01
Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...
A Laboratory Experiment for Rapid Determination of the Stability of Vitamin C
ERIC Educational Resources Information Center
Adem, Seid M.; Lueng, Sam H.; Elles, Lisa M. Sharpe; Shaver, Lee Alan
2016-01-01
Experiments in laboratory manuals intended for general, organic, and biological (GOB) chemistry laboratories include few opportunities for students to engage in instrumental methods of analysis. Many of these students seek careers in modern health-related fields where experience in spectroscopic techniques would be beneficial. A simple, rapid,…
2013-01-01
Background Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. Results We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. Conclusion CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets. PMID:23617892
Yang, Fang; Chia, Nicholas; White, Bryan A; Schook, Lawrence B
2013-04-23
Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets.
Cui, Jiayue; Chai, David I.; Miller, Christopher; Hao, Jason; Thomas, Christopher; Wang, JingQi; Scheidt, Karl A.; Kozmin, Sergey A.
2013-01-01
We describe a unified synthetic strategy for efficient assembly of four new heterocyclic libraries. The synthesis began by creating a range of structurally diverse pyrrolidinones or piperidinones. Such compounds were obtained in a simple one-flask operation starting with readily available amines, ketoesters, and unsaturated anhydrides. The use of tetrahydropyran-containing ketoesters, which were rapidly assembled by our Prins cyclization protocol, enabled efficient fusion of pyran and piperidinone cores. A newly developed Au(I)-catalyzed cycloisomerization of alkyne-containing enamides further expanded heterocyclic diversity by providing rapid entry into a wide range of bicyclic and tricyclic dienamides. The final stage of the process entailed diversification of each of the initially produced carboxylic acids using a fully automated platform for amide synthesis, which delivered 1872 compounds in high diastereomeric and chemical purity. PMID:22860634
Advantages and disadvantages of endoscopically assisted front-lift.
Dusková, M; Padĕra, J; Kristen, M
2002-01-01
Reduced surgical risk, a diminution of visible scars, rapid recovery, long-termed results and reduced costs are at present the most important demands on development in aesthetic plastic surgery. Endoscopically assisted front-lift meets perfectly the need of reduced invasiveness. It is technically simple and associated with a minimum of complications. It brings minimal scars beyond the hairline with a favourable effect after eliminating the drop of the brows, and wrinkles on the forehead. The duration of the effect in the aging face depends, however, similarly as other methods, on the characteristics of the skin, changes in other parts and the individual disposition. A marked disadvantage is the high initial, cost of special equipment. Their recovery ensues from the reduced time of surgery, reduced consumption of material, lower number of complications and more rapid return to normal life.
NASA Astrophysics Data System (ADS)
Susanto, B. H.; Prakasa, M. B.; Shahab, M. H.
2016-11-01
The synthesis of metal nanocrystal was conducted by modification preparation from simple heating method which heating and cooling process run rapidly. The result of NiMo/Z 575 °C characterizations are 33.73 m2/gram surface area and 31.80 nm crystal size. By used NiMo/C 700 °C catalyst for 30 minutes which had surface area of 263.21 m2/gram, had 31.77 nm crystal size, and good morphology, obtained catalyst with high activity, selectivity, and stability. After catalyst activated, synthesis of renewable diesel performed in hydrogenation reactor at 375 °C, 12 bar, and 800 rpm. The result of conversion was 81.99%, yield was 68.08%, and selectivity was 84.54%.
Rapid Evaporation in Fuel Injection
NASA Astrophysics Data System (ADS)
McCahan, S.; Kessler, C.
1997-11-01
Preheating fuel prior to injection through a nozzle can induce a superheated state during expansion. The resulting rapid evaporation improves atomization of the fluid and, therefore, may improve combustion efficiency. A sufficient degree of superheat im posed on a fuel with a high specific heat (retrograde fluid) can theoretically result in complete evaporation. In the work done by Sloss and McCahan (APS/DFD meeting 1996), dodecane, fuel oil, kerosene, and diesel oil were studied. In this continuation of the same study, decane and tetradecane are preheated to temperatures ranging from 20^oC to 330^oC at a p ressure of 10 bar and injected into a chamber at 1 bar. A simple converging nozzle is used. Photographs taken of the resulting sprays are used to determine cone angles and make qualitative observations of droplet size and spray structure.
Rapid decrease of radar cross section of meteor head echo observed by the MU radar
NASA Astrophysics Data System (ADS)
Nakamura, T.; Nishio, M.; Sato, T.; Tsutsumi, S.; Tsuda, T.; Fushimi, K.
The meteor head echo observation using the MU (Middle and Upper atmosphere) radar (46.5M Hz, 1MW), Shigaraki, Japan, was carried out simultaneously with a high sensitive ICCD (Image-intensified CCD) camera observation in November 2001. The time records were synchronized using GPS satellite signals, in order to compare instantaneous radar and optical meteor magnitudes. 26 faint meteors were successfully observed simultaneously by both equipments. Detailed comparison of the time variation of radar echo intensity and absolute optical magnitude showed that the radar scattering cross section is likely to decrease rapidly by 5 - 20 dB without no corresponding magnitude variation in the optical data. From a simple modeling, we concluded that such decrease of RCS (radar cross section ) is probably due to the transition from overdense head echo to underd ense head echo.
Poisoning by Herbs and Plants: Rapid Toxidromic Classification and Diagnosis.
Diaz, James H
2016-03-01
The American Association of Poison Control Centers has continued to report approximately 50,000 telephone calls or 8% of incoming calls annually related to plant exposures, mostly in children. Although the frequency of plant ingestions in children is related to the presence of popular species in households, adolescents may experiment with hallucinogenic plants; and trekkers and foragers may misidentify poisonous plants as edible. Since plant exposures have continued at a constant rate, the objectives of this review were (1) to review the epidemiology of plant poisonings; and (2) to propose a rapid toxidromic classification system for highly toxic plant ingestions for field use by first responders in comparison to current classification systems. Internet search engines were queried to identify and select peer-reviewed articles on plant poisonings using the key words in order to classify plant poisonings into four specific toxidromes: cardiotoxic, neurotoxic, cytotoxic, and gastrointestinal-hepatotoxic. A simple toxidromic classification system of plant poisonings may permit rapid diagnoses of highly toxic versus less toxic and nontoxic plant ingestions both in households and outdoors; direct earlier management of potentially serious poisonings; and reduce costly inpatient evaluations for inconsequential plant ingestions. The current textbook classification schemes for plant poisonings were complex in comparison to the rapid classification system; and were based on chemical nomenclatures and pharmacological effects, and not on clearly presenting toxidromes. Validation of the rapid toxidromic classification system as compared to existing chemical classification systems for plant poisonings will require future adoption and implementation of the toxidromic system by its intended users. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests.
Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline; Lindegren, Gunnel; Stoltz, Malin Lundahl; Salata, Cristiano; Kran, Anne-Marte Bakken; Dudman, Susanne Gjeruldsen; Mirazimi, Ali; Fomsgaard, Anders
2016-10-01
Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using the QIAamp viral RNA minikit. We present an easy and convenient method for bedside inactivation using available blood collection vacuum tubes and reagents. We propose to use this simple method for fast, safe, and easy bedside inactivation of Ebola virus for safe transport and routine nucleic acid detection. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Afrough, Babak; Mullojonova, Manija; Dzhuraeva, Viktoriya; Tishkova, Farida; Hewson, Roger
2017-01-01
Background Crimean-Congo Haemorrhagic fever Virus (CCHFV) is a rapidly emerging vector-borne pathogen and the cause of a virulent haemorrhagic fever affecting large parts of Europe, Africa, the Middle East and Asia. Methodology/principle findings An isothermal recombinase polymerase amplification (RPA) assay was successfully developed for molecular detection of CCHFV. The assay showed rapid (under 10 minutes) detection of viral extracts/synthetic virus RNA of all 7 S-segment clades of CCHFV, with high target specificity. The assay was shown to tolerate the presence of inhibitors in crude preparations of mock field samples, indicating that this assay may be suitable for use in the field with minimal sample preparation. The CCHFV RPA was successfully used to screen and detect CCHFV positives from a panel of clinical samples from Tajikistan. Conclusions/significance The assay is a rapid, isothermal, simple-to-perform molecular diagnostic, which can be performed on a light, portable real-time detection device. It is ideally placed therefore for use as a field-diagnostic or in-low resource laboratories, for monitoring of CCHF outbreaks at the point-of-need, such as in remote rural regions in affected countries. PMID:29028804
Iodine-131 radiolabeling of poly ethylene glycol-coated gold nanorods for in vivo imaging.
Eskandari, Najmeh; Yavari, Kamal; Outokesh, Mohammad; Sadjadi, Sodeh; Ahmadi, Seyed Javad
2013-01-01
Gold nanorods (GNRs) can be used in various biomedical applications; however, very little is known about their in vivo tissue distribution by radiolabeling. Here, we have developed a rapid and simple method with high yield and without disturbing their optical properties for radiolabeling of gold rods with iodine-131 in order to track in vivo tissue uptake of GNRs after systemic administration by biodistribution analysis and γ-imaging. Following intravenous injection into rat, PEGylated GNRs have much longer blood circulation times. Copyright © 2012 John Wiley & Sons, Ltd.
Periodate oxidation of nanoscaled magnetic dextran composites
NASA Astrophysics Data System (ADS)
Hong, Xia; Guo, Wei; Yuan, Hang; Li, Jun; Liu, Yanmei; Ma, Lan; Bai, Yubai; Li, Tiejin
2004-02-01
Highly hydrophilic, uniform and nontoxic magnetic fluids consisting of magnetite (Fe 3O 4) and dextran were prepared. A periodate oxidation method was used to further activate the magnetic dextran, forming magnetic polyaldehyde-dextran, which could be conjugated to biomolecules such as proteins or antibodies. Oxidated Magnetic dextran composites were characterized by TEM, XRD and SQUID magnetometry. Moreover, a flexible, rapid and simple method to detect aldehydes was introduced to the magnetic composite system by utilizing 2,4-dinitrophenylhydrazine reagent. The result of the quantitative analysis of aldehyde was given by thermogravimetric analysis and elemental analysis.
Decarboxylative Fluorination of Aliphatic Carboxylic Acids via Photoredox Catalysis
Ventre, Sandrine; Petronijevic, Filip R.; MacMillan, David W. C.
2016-01-01
The direct conversion of aliphatic carboxylic acids to the corresponding alkyl fluorides has been achieved via visible light-promoted photoredox catalysis. This operationally simple, redox-neutral fluorination method is amenable to a wide variety of carboxylic acids. Photon-induced oxidation of carboxylates leads to the formation of carboxyl radicals, which upon rapid CO2-extrusion and F• transfer from a fluorinating reagent yield the desired fluoroalkanes with high efficiency. Experimental evidence indicates that an oxidative quenching pathway is operable in this broadly applicable fluorination protocol. PMID:25881929
Lin, Zhichao; Wu, Zhongyu
2009-05-01
A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of (210)Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.
2010-01-01
Research in plant molecular biology involves DNA purification on a daily basis. Although different commercial kits enable convenient extraction of high-quality DNA from E. coli cells, PCR and agarose gel samples as well as plant tissues, each kit is designed for a particular type of DNA extraction work, and the cost of purchasing these kits over a long run can be considerable. Furthermore, a simple method for the isolation of binary plasmid from Agrobacterium tumefaciens cells with satisfactory yield is lacking. Here we describe an easy protocol using homemade silicon dioxide matrix and seven simple solutions for DNA extraction from E. coli and A. tumefaciens cells, PCR and restriction digests, agarose gel slices, and plant tissues. Compared with the commercial kits, this protocol allows rapid DNA purification from diverse sources with comparable yield and purity at negligible cost. Following this protocol, we have demonstrated: (1) DNA fragments as small as a MYC-epitope tag coding sequence can be successfully recovered from an agarose gel slice; (2) Miniprep DNA from E. coli can be eluted with as little as 5 μl water, leading to high DNA concentrations (>1 μg/μl) for efficient biolistic bombardment of Arabidopsis seedlings, polyethylene glycol (PEG)-mediated Arabidopsis protoplast transfection and maize protoplast electroporation; (3) Binary plasmid DNA prepared from A. tumefaciens is suitable for verification by restriction analysis without the need for large scale propagation; (4) High-quality genomic DNA is readily isolated from several plant species including Arabidopsis, tobacco and maize. Thus, the silicon dioxide matrix-based DNA purification protocol offers an easy, efficient and economical way to extract DNA for various purposes in plant research. PMID:20180960
Giménez, Estela; Gay, Marina; Vilaseca, Marta
2017-01-30
Here we demonstrate the potential of nano-UPLC-LTQ-FT-MS and the Byonic™ proteomic search engine for the separation, detection, and identification of N- and O-glycopeptide glycoforms in standard glycoproteins. The use of a BEH C18 nanoACQUITY column allowed the separation of the glycopeptides present in the glycoprotein digest and a baseline-resolution of the glycoforms of the same glycopeptide on the basis of the number of sialic acids. Moreover, we evaluated several acquisition strategies in order to improve the detection and characterization of glycopeptide glycoforms with the maximum number of identification percentages. The proposed strategy is simple to set up with the technology platforms commonly used in proteomic labs. The method allows the straightforward and rapid obtention of a general glycosylated map of a given protein, including glycosites and their corresponding glycosylated structures. The MS strategy selected in this work, based on a gas phase fractionation approach, led to 136 unique peptides from four standard proteins, which represented 78% of the total number of peptides identified. Moreover, the method does not require an extra glycopeptide enrichment step, thus preventing the bias that this step could cause towards certain glycopeptide species. Data are available via ProteomeXchange with identifier PXD003578. We propose a simple and high-throughput glycoproteomics-based methodology that allows the separation of glycopeptide glycoforms on the basis of the number of sialic acids, and their automatic and rapid identification without prior knowledge of protein glycosites or type and structure of the glycans. Copyright © 2016 Elsevier B.V. All rights reserved.
Zeinhom, Mohamed Maarouf Ali; Wang, Yijia; Song, Yang; Zhu, Mei-Jun; Lin, Yuehe; Du, Dan
2018-01-15
The detection of E. coli O157:H7 in foods has held the attention of many researchers because of the seriousness attributed to this pathogen. In this study, we present a simple, sensitive, rapid and portable smartphone based fluorescence device for E. coli O157:H7 detection. This field-portable fluorescent imager on the smartphone involves a compact laser-diode-based photosource, a long-pass (LP) thin-film interference filter and a high-quality insert lenses. The design of the device provided a low noise to background imaging system. Based on a sandwich ELISA and the specific recognition of antibody to E. coli O157:H7, the sensitive detection of E. coli O157:H7 were realized both in standard samples and real matrix in yoghurt and egg on our device. The detection limit are 1 CFU/mL and 10 CFU/mL correspondingly. Recovery percentages of spiked yogurt and egg samples with 10 3 , 10 4 and 10 5 CFU/mL E. coli O157:H7 were 106.98, 96.52 and 102.65 (in yogurt) and 107.37, 105.64 and 93.84 (in egg) samples using our device, respectively. Most importantly, the entire process could be quickly completed within two hours. This smartphone based device provides a simple, rapid, sensitive detection platform for fluorescent imaging which applied in pathogen detection for food safety monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Ayesh, Basim M
2017-01-01
Molecular markers are credible for the discrimination of genotypes and estimation of the extent of genetic diversity and relatedness in a set of genotypes. Inter-simple sequence repeat (ISSR) markers rapidly reveal high polymorphic fingerprints and have been used frequently to determine the genetic diversity among date palm cultivars. This chapter describes the application of ISSR markers for genotyping of date palm cultivars. The application involves extraction of genomic DNA from the target cultivars with reliable quality and quantity. Subsequently the extracted DNA serves as a template for amplification of genomic regions flanked by inverted simple sequence repeats using a single primer. The similarity of each pair of samples is measured by calculating the number of mono- and polymorphic bands revealed by gel electrophoresis. Matrices constructed for similarity and genetic distance are used to build a phylogenetic tree and cluster analysis, to determine the molecular relatedness of cultivars. The protocol describes 3 out of 9 tested primers consistently amplified 31 loci in 6 date palm cultivars, with 28 polymorphic loci.
Axial resonance of periodic patterns by using a Fresnel biprism.
Doblas, Ana; Saavedra, Genaro; Martinez-Corral, Manuel; Barreiro, Juan C; Sanchez-Ortiga, Emilio; Llavador, Anabel
2013-01-01
This paper proposes a method for the generation of high-contrast localized sinusoidal fringes with spatially noncoherent illumination and relatively high light throughput. The method, somehow similar to the classical Lau effect, is based on the use of a Fresnel biprism. It has some advantages over previous methods for the noncoherent production of interference fringes. One is the flexibility of the method, which allows the control of the fringe period by means of a simple axial shift of the biprism. Second is the rapid axial fall-off in visibility around the high-contrast fringe planes. And third is the possibility of creating fringes with increasing or with constant period as the light beam propagates. Experimental verifications of the theoretical statements are also provided.
Chen, LiQin; Wang, Hui; Xu, Zhen; Zhang, QiuYue; Liu, Jia; Shen, Jun; Zhang, WanQi
2018-08-03
In the present study, we developed a simple and high-throughput solid phase extraction (SPE) procedure for selective extraction of catecholamines (CAs) in urine samples. The SPE adsorbents were electrospun composite fibers functionalized with 4-carboxybenzo-18-crown-6 ether modified XAD resin and polystyrene, which were packed into 96-well columns and used for high-throughput selective extraction of CAs in healthy human urine samples. Moreover, the extraction efficiency of packed-fiber SPE (PFSPE) was examined by high performance liquid chromatography coupled with fluorescence detector. The parameters affecting the extraction efficiency and impurity removal efficiency were optimized, and good linearity ranging from 0.5 to 400 ng/mL was obtained with a low limit of detection (LOD, 0.2-0.5 ng/mL) and a good repeatability (2.7%-3.7%, n = 6). The extraction recoveries of three CAs ranged from 70.5% to 119.5%. Furthermore, stable and reliable results obtained by the fluorescence detector were superior to those obtained by the electrochemical detector. Collectively, PFSPE coupled with 96-well columns was a simple, rapid, selective, high-throughput and cost-efficient method, and the proposed method could be applied in clinical chemistry. Copyright © 2018 Elsevier B.V. All rights reserved.
Tong, Runna; Peng, Mijun; Tong, Chaoying; Guo, Keke; Shi, Shuyun
2018-03-01
Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction for Fructus aurantii immaturus (Zhishi), OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of eighteen flavonoids were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and compound 9, natsudaidain-3-O-glucoside, was discovered in Zhishi for the first time. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2018. Published by Elsevier B.V.
Ruiz, David; Reich, Maryse; Bureau, Sylvie; Renard, Catherine M G C; Audergon, Jean-Marc
2008-07-09
The importance of carotenoid content in apricot (Prunus armeniaca L.) is recognized not only because of the color that they impart but also because of their protective activity against human diseases. Current methods to assess carotenoid content are time-consuming, expensive, and destructive. In this work, the application of rapid and nondestructive methods such as colorimeter measurements and infrared spectroscopy has been evaluated for carotenoid determination in apricot. Forty apricot genotypes covering a wide range of peel and flesh colors have been analyzed. Color measurements on the skin and flesh ( L*, a*, b*, hue, chroma, and a*/ b* ratio) as well as Fourier transform near-infrared spectroscopy (FT-NIR) on intact fruits and Fourier transform mid-infrared spectroscopy (FT-MIR) on ground flesh were correlated with the carotenoid content measured by high-performance liquid chromatography. A high variability in color values and carotenoid content was observed. Partial least squares regression analyses between beta-carotene content and provitamin A activity and color measurements showed a high fit in peel, flesh, and edible apricot portion (R(2) ranged from 0.81 to 0.91) and low prediction error. Regression equations were developed for predicting carotenoid content by using color values, which appeared as a simple, rapid, reliable, and nondestructive method. However, FT-NIR and FT-MIR models showed very low R(2) values and very high prediction errors for carotenoid content.
ERIC Educational Resources Information Center
Torppa, Minna; Georgiou, George K.; Lerkkanen, Marja-Kristiina; Niemi, Pekka; Poikkeus, Anna-Maija
2016-01-01
This study examined the dynamic relationships among the components of the Simple View of Reading (SVR) in a transparent orthography (Finnish) and the predictive value of cognitive skills (phonological awareness, letter knowledge, rapid naming, and vocabulary) on the SVR components. Altogether, 1,815 Finnish children were followed from kindergarten…
Starting to Experiment with Wave Power
ERIC Educational Resources Information Center
Hare, Jonathan; McCallie, Ellen
2005-01-01
Outlined is a simple design for a working wave-powered electrical generator based on one made on the BBC "Rough Science" TV series. The design has been kept deliberately simple to facilitate rapid pupil/student involvement and most importantly so that there is much scope for their own ingenuity and ideas. The generator works on the principle of…
Goller, K V; Dill, V; Madi, M; Martin, P; Van der Stede, Y; Vandenberge, V; Haas, B; Van Borm, S; Koenen, F; Kasanga, C J; Ndusilo, N; Beer, M; Liu, L; Mioulet, V; Armson, B; King, D P; Fowler, V L
2018-04-01
Highly contagious transboundary animal diseases such as foot-and-mouth disease (FMD) are major threats to the productivity of farm animals. To limit the impact of outbreaks and to take efficient steps towards a timely control and eradication of the disease, rapid and reliable diagnostic systems are of utmost importance. Confirmatory diagnostic assays are typically performed by experienced operators in specialized laboratories, and access to this capability is often limited in the developing countries with the highest disease burden. Advances in molecular technologies allow implementation of modern and reliable techniques for quick and simple pathogen detection either in basic laboratories or even at the pen-side. Here, we report on a study to evaluate a fully automated cartridge-based real-time RT-PCR diagnostic system (Enigma MiniLab ® ) for the detection of FMD virus (FMDV). The modular system integrates both nucleic acid extraction and downstream real-time RT-PCR (rRT-PCR). The analytical sensitivity of this assay was determined using serially diluted culture grown FMDV, and the performance of the assay was evaluated using a selected range of FMDV positive and negative clinical samples of bovine, porcine and ovine origin. The robustness of the assay was evaluated in an international inter-laboratory proficiency test and by deployment into an African laboratory. It was demonstrated that the system is easy to use and can detect FMDV with high sensitivity and specificity, roughly on par with standard laboratory methods. This cartridge-based automated real-time RT-PCR system for the detection of FMDV represents a reliable and easy to use diagnostic tool for the early and rapid disease detection of acutely infected animals even in remote areas. This type of system could be easily deployed for routine surveillance within endemic regions such as Africa or could alternatively be used in the developed world. © 2017 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
A 48 SNP set for grapevine cultivar identification
2011-01-01
Background Rapid and consistent genotyping is an important requirement for cultivar identification in many crop species. Among them grapevine cultivars have been the subject of multiple studies given the large number of synonyms and homonyms generated during many centuries of vegetative multiplication and exchange. Simple sequence repeat (SSR) markers have been preferred until now because of their high level of polymorphism, their codominant nature and their high profile repeatability. However, the rapid application of partial or complete genome sequencing approaches is identifying thousands of single nucleotide polymorphisms (SNP) that can be very useful for such purposes. Although SNP markers are bi-allelic, and therefore not as polymorphic as microsatellites, the high number of loci that can be multiplexed and the possibilities of automation as well as their highly repeatable results under any analytical procedure make them the future markers of choice for any type of genetic identification. Results We analyzed over 300 SNP in the genome of grapevine using a re-sequencing strategy in a selection of 11 genotypes. Among the identified polymorphisms, we selected 48 SNP spread across all grapevine chromosomes with allele frequencies balanced enough as to provide sufficient information content for genetic identification in grapevine allowing for good genotyping success rate. Marker stability was tested in repeated analyses of a selected group of cultivars obtained worldwide to demonstrate their usefulness in genetic identification. Conclusions We have selected a set of 48 stable SNP markers with a high discrimination power and a uniform genome distribution (2-3 markers/chromosome), which is proposed as a standard set for grapevine (Vitis vinifera L.) genotyping. Any previous problems derived from microsatellite allele confusion between labs or the need to run reference cultivars to identify allele sizes disappear using this type of marker. Furthermore, because SNP markers are bi-allelic, allele identification and genotype naming are extremely simple and genotypes obtained with different equipments and by different laboratories are always fully comparable. PMID:22060012
Shih, Hou-Kuang; Shu, Ting-Yun; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon
2015-01-07
In this study, a novel fatty-acid-based in-tube dispersive liquid-liquid microextraction (FA-IT-DLLME) technique is proposed for the first time and is developed as a simple, rapid and eco-friendly sample extraction method for the determination of alkylphenols in aqueous samples using high-performance liquid chromatography-ultraviolet detection (HPLC-UV). In this extraction method, medium-chain saturated fatty acids were investigated as a pH-dependent phase because they acted as either anionic surfactants or neutral extraction solvents based on the acid-base reaction caused solely by the adjustment of the pH of the solution. A specially designed home-made glass extraction tube with a built-in scaled capillary tube was utilized as the phase-separation device for the FA-IT-DLLME to collect and measure the separated extractant phase for analysis. Nonylphenol (NP) and 4-tert-octylphenol (4-tOP) were chosen as model analytes. The parameters influencing the FA-IT-DLLME were thoroughly investigated and optimized. Under the optimal conditions, the detector responses of NP and 4-tOP were linear in the concentration ranges of 5-4000 μg L(-1), with correlation coefficients of 0.9990 and 0.9996 for NP and 4-tOP, respectively. The limits of detection based on a signal-to-noise ratio of 3 were 0.7 and 0.5 μg L(-1), and the enrichment factors were 195 and 143 for NP and 4-tOP, respectively. The applicability of the developed method was demonstrated for the analysis of alkylphenols in environmental wastewater samples, and the recoveries ranged from 92.9 to 107.1%. The extraction process required less than 4 min and utilized only acids, alkalis, and fatty acids to achieve the extraction. The results demonstrated that the presented FA-IT-DLLME approach is highly cost-effective, simple, rapid and environmentally friendly in its sample preparation. Copyright © 2014 Elsevier B.V. All rights reserved.
Ullal-Gupta, Sangeeta; Hannon, Erin E.; Snyder, Joel S.
2014-01-01
Musical meters vary considerably across cultures, yet relatively little is known about how culture-specific experience influences metrical processing. In Experiment 1, we compared American and Indian listeners' synchronous tapping to slow sequences. Inter-tone intervals contained silence or to-be-ignored rhythms that were designed to induce a simple meter (familiar to Americans and Indians) or a complex meter (familiar only to Indians). A subset of trials contained an abrupt switch from one rhythm to another to assess the disruptive effects of contradicting the initially implied meter. In the unfilled condition, both groups tapped earlier than the target and showed large tap-tone asynchronies (measured in relative phase). When inter-tone intervals were filled with simple-meter rhythms, American listeners tapped later than targets, but their asynchronies were smaller and declined more rapidly. Likewise, asynchronies rose sharply following a switch away from simple-meter but not from complex-meter rhythm. By contrast, Indian listeners performed similarly across all rhythm types, with asynchronies rapidly declining over the course of complex- and simple-meter trials. For these listeners, a switch from either simple or complex meter increased asynchronies. Experiment 2 tested American listeners but doubled the duration of the synchronization phase prior to (and after) the switch. Here, compared with simple meters, complex-meter rhythms elicited larger asynchronies that declined at a slower rate, however, asynchronies increased after the switch for all conditions. Our results provide evidence that ease of meter processing depends to a great extent on the amount of experience with specific meters. PMID:25075514
Fernandes, Richard; Carey, Conn; Hynes, James; Papkovsky, Dmitri
2013-01-01
The importance of food safety has resulted in a demand for a more rapid, high-throughput method for total viable count (TVC). The industry standard for TVC determination (ISO 4833:2003) is widely used but presents users with some drawbacks. The method is materials- and labor-intensive, requiring multiple agar plates per sample. More importantly, the method is slow, with 72 h typically required for a definitive result. Luxcel Biosciences has developed the GreenLight Model 960, a microtiter plate-based assay providing a rapid high-throughput method of aerobic bacterial load assessment through analysis of microbial oxygen consumption. Results are generated in 1-12 h, depending on microbial load. The mix and measure procedure allows rapid detection of microbial oxygen consumption and equates oxygen consumption to microbial load (CFU/g), providing a simple, sensitive means of assessing the microbial contamination levels in foods (1). As bacteria in the test sample grow and respire, they deplete O2, which is detected as an increase in the GreenLight probe signal above the baseline level (2). The time required to reach this increase in signal can be used to calculate the CFU/g of the original sample, based on a predetermined calibration. The higher the initial microbial load, the earlier this threshold is reached (1).
Lang, Jillian M.; Langlois, Paul; Nguyen, Marian Hanna R.; Triplett, Lindsay R.; Purdie, Laura; Holton, Timothy A.; Djikeng, Appolinaire; Vera Cruz, Casiana M.; Verdier, Valérie
2014-01-01
Molecular diagnostics for crop diseases can enhance food security by enabling the rapid identification of threatening pathogens and providing critical information for the deployment of disease management strategies. Loop-mediated isothermal amplification (LAMP) is a PCR-based tool that allows the rapid, highly specific amplification of target DNA sequences at a single temperature and is thus ideal for field-level diagnosis of plant diseases. We developed primers highly specific for two globally important rice pathogens, Xanthomonas oryzae pv. oryzae, the causal agent of bacterial blight (BB) disease, and X. oryzae pv. oryzicola, the causal agent of bacterial leaf streak disease (BLS), for use in reliable, sensitive LAMP assays. In addition to pathovar distinction, two assays that differentiate X. oryzae pv. oryzae by African or Asian lineage were developed. Using these LAMP primer sets, the presence of each pathogen was detected from DNA and bacterial cells, as well as leaf and seed samples. Thresholds of detection for all assays were consistently 104 to 105 CFU ml−1, while genomic DNA thresholds were between 1 pg and 10 fg. Use of the unique sequences combined with the LAMP assay provides a sensitive, accurate, rapid, simple, and inexpensive protocol to detect both BB and BLS pathogens. PMID:24837384
Ren, Xinxin; Liu, Jia; Zhang, Chengsen; Sun, Jiamu; Luo, Hai
2014-01-15
It is difficult to directly analyze carboxylic acids in complex mixtures by ambient high-voltage-assisted laser desorption ionization mass spectrometry (HALDI-MS) in negative ion mode due to the low ionization efficiency of carboxylic acids. A method for the rapid detection of carboxylic acids in negative HALDI-MS has been developed based on their inclusion with β-cyclodextrin (β-CD). The negative HALDI-MS signal-to-noise ratios (S/Ns) of aliphatic, aromatic and hetero atom-containing carboxylic acids can all be significantly improved by forming 1:1 complexes with β-CD. These complexes are mainly formed by specific inclusion interactions which are verified by their collision-induced dissociation behaviors in comparison with that of their corresponding maltoheptaose complexes. A HALDI-MS/MS method has been successfully developed for the detection of α-lipoic acid in complex cosmetics and ibuprofen in a viscous drug suspension. The negative HALDI-MS S/Ns of carboxylic acids can be improved up to 30 times via forming non-covalent complexes with β-CD. The developed method shows the advantages of being rapid and simple, and is promising for rapid detection of active ingredients in complex samples or fast screening of drugs and cosmetics. Copyright © 2013 John Wiley & Sons, Ltd.
Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; Shentu, Jianzhong
2014-01-01
A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5 μ m) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012-5.78 ng·mL(-1) for blonanserin and 0.023-11.57 ng·mL(-1) for blonanserin C (r (2) > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers.
Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; ShenTu, Jianzhong
2014-01-01
A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5 μm) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012–5.78 ng·mL−1 for blonanserin and 0.023–11.57 ng·mL−1 for blonanserin C (r 2 > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers. PMID:24678425
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
2015-01-01
Bacterial meningitis is a serious health concern worldwide. Given that meningitis can be fatal and many meningitis cases occurred in high-poverty areas, a simple, low-cost, highly sensitive method is in great need for immediate and early diagnosis of meningitis. Herein, we report a versatile and cost-effective polydimethylsiloxane (PDMS)/paper hybrid microfluidic device integrated with loop-mediated isothermal amplification (LAMP) for the rapid, sensitive, and instrument-free detection of the main meningitis-causing bacteria, Neisseria meningitidis (N. meningitidis). The introduction of paper into the microfluidic device for LAMP reactions enables stable test results over a much longer period of time than a paper-free microfluidic system. This hybrid system also offers versatile functions, by providing not only on-site qualitative diagnostic analysis (i.e., a yes or no answer), but also confirmatory testing and quantitative analysis in laboratory settings. The limit of detection of N. meningitidis is about 3 copies per LAMP zone within 45 min, close to single-bacterium detection sensitivity. In addition, we have achieved simple pathogenic microorganism detection without a laborious sample preparation process and without the use of centrifuges. This low-cost hybrid microfluidic system provides a simple and highly sensitive approach for fast instrument-free diagnosis of N. meningitidis in resource-limited settings. This versatile PDMS/paper microfluidic platform has great potential for the point of care (POC) diagnosis of a wide range of infectious diseases, especially for developing nations. PMID:25019330
Block Copolymer Nanocomposites with High Refractive Index Contrast for One-Step Photonics.
Song, Dong-Po; Li, Cheng; Li, Wenhao; Watkins, James J
2016-01-26
Photonic crystals (PhCs) prepared using the self-assembly of block copolymers (BCPs) offer the potential for simple and rapid device fabrication but typically suffer from low refractive index contrast (Δn ≤ 0.1) between the phase-segregated domains. Here, we report the simple fabrication of BCP-based photonic nanocomposites with large differences in refractive index (Δn > 0.27). Zirconium oxide (ZrO2) nanoparticles coated with gallic acid are used to tune the optical constants of the target domains of self-assembled (polynorbornene-graft-poly(tert-butyl acrylate))-block-(polynorbornene-graft-poly(ethylene oxide)) (PtBA-b-PEO) brush block copolymers (BBCPs). Strong hydrogen-bonding interactions between the ligands on ZrO2 and PEO brushes of the BBCPs enable selective incorporation and high loading of up to 70 wt % (42 vol %) of the ZrO2 nanoparticles within the PEO domain, resulting in a significant increase of refractive index from 1.45 to up to 1.70. Consequently, greatly enhanced reflection at approximately 398 nm (increases of ∼250%) was observed for the photonic nanocomposites (domain spacing = 137 nm) relative to that of the unmodified BBCPs, which is consistent with numeric modeling results using transfer matrix methods. This work provides a simple strategy for a wide range tuning of optical constants of BCP domains, thereby enabling the design and creation of high-performance photonic coatings for various applications. The large refractive index contrast enables high reflectivity while simultaneously reducing the coating thickness necessary, compared to pure BCP systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meeks, Kelsey; Pantoya, Michelle L.; Green, Micah
For dispersions containing a single type of particle, it has been observed that the onset of percolation coincides with a critical value of volume fraction. When the volume fraction is calculated based on excluded volume, this critical percolation threshold is nearly invariant to particle shape. The critical threshold has been calculated to high precision for simple geometries using Monte Carlo simulations, but this method is slow at best, and infeasible for complex geometries. This article explores an analytical approach to the prediction of percolation threshold in polydisperse mixtures. Specifically, this paper suggests an extension of the concept of excluded volume,more » and applies that extension to the 2D binary disk system. The simple analytical expression obtained is compared to Monte Carlo results from the literature. In conclusion, the result may be computed extremely rapidly and matches key parameters closely enough to be useful for composite material design.« less
Magneto-hydrodynamic modeling of gas discharge switches
NASA Astrophysics Data System (ADS)
Doiphode, P.; Sakthivel, N.; Sarkar, P.; Chaturvedi, S.
2002-12-01
We have performed one-dimensional, time-dependent magneto-hydrodynamic modeling of fast gas-discharge switches. The model has been applied to both high- and low-pressure switches, involving a cylindrical argon-filled cavity. It is assumed that the discharge is initiated in a small channel near the axis of the cylinder. Joule heating in this channel rapidly raises its temperature and pressure. This drives a radial shock wave that heats and ionizes the surrounding low-temperature region, resulting in progressive expansion of the current channel. Our model is able to reproduce this expansion. However, significant difference of detail is observed, as compared with a simple model reported in the literature. In this paper, we present details of our simulations, a comparison with results from the simple model, and a physical interpretation for these differences. This is a first step towards development of a detailed 2-D model for such switches.
Results from the GSFC fluxgate magnetometer on Pioneer 11
NASA Technical Reports Server (NTRS)
Acuna, M. H.; Ness, N. F.
1976-01-01
A high-field triaxial fluxgate magnetometer was mounted on Pioneer 11 to measure the main magnetic field of Jupiter. It is found that this planetary magnetic field is more complex than that indicated by the results of the Pioneer 10 vector helium magnetometer. At distances less than 3 Jupiter radii, the magnetic field is observed to increase more rapidly than an inverse-cubed distance law associated with any simple dipole model. Contributions from higher-order multipoles are significant, with the quadrupole and octupole being 24 and 21 percent of the dipole moment, respectively. Implications of the results for the study of trapped particles, planetary radio emission, and planetary interiors are discussed. Major conclusions are that the deviation of the main planetary magnetic field from a simple dipole leads to distortion of the L shells of the charged particles and to warping of the magnetic equator. Enhanced absorption effects associated with Amalthea and Io are predicted.
Cai, Longfei; Zhong, Minghua; Li, Huolin; Xu, Chunxiu; Yuan, Biyu
2015-07-01
We describe a simple and cost-effective strategy for rapid fabrication of microfluidic paper-based analytical devices and valves by inkjet printing. NaOH aqueous solution was printed onto a hydrophobic filter paper, which was previously obtained by soaking in a trimethoxyoctadecylsilane-heptane solution, allowing selective wet etching of hydrophobic cellulose to create hydrophilic-hydrophobic contrast with a relatively good resolution. Hexadecyltrimethylammonium bromide (CTMAB)-ethanol solution was printed onto hydrophobic paper to fabricate temperature-controlled valves. At low temperature, CTMAB deposited on the paper is insoluble in aqueous fluid, thus the paper remains hydrophobic. At high temperature, CTMAB becomes soluble so the CTMAB-deposited channel becomes hydrophilic, allowing the wicking of aqueous solution through the valve. We believe that this strategy will be very attractive for the development of simple micro analytical devices for point-of-care applications, including diagnostic testing, food safety control, and environmental monitoring.
Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study
Jalali, Amir; Hatamie, Amir; Saferpour, Tahere; Khajeamiri, Alireza; Safa, Tahere; Buazar, Foad
2016-01-01
In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method showed that unambiguous identification can be achieved for MDMA from 3, 4-methylenedioxyamphetamine (MDA), Amphetamine (AM), methamphetamine (MA) and ketamine (Keta) compounds, respectively. The experimental results indicated the acceptable time window without interfering peaks. It is found that GC-MS was provided a suitable and rapid identification approach for MDMA (Ecstacy) tablets, particularly in the Forensic labs. Consequently, the intense MDMA levels would support the police to develop a simple quantification of impurity in Ecstasy tablets. PMID:27610162
Time-dependent inhomogeneous jet models for BL Lac objects
NASA Technical Reports Server (NTRS)
Marlowe, A. T.; Urry, C. M.; George, I. M.
1992-01-01
Relativistic beaming can explain many of the observed properties of BL Lac objects (e.g., rapid variability, high polarization, etc.). In particular, the broadband radio through X-ray spectra are well modeled by synchrotron-self Compton emission from an inhomogeneous relativistic jet. We have done a uniform analysis on several BL Lac objects using a simple but plausible inhomogeneous jet model. For all objects, we found that the assumed power-law distribution of the magnetic field and the electron density can be adjusted to match the observed BL Lac spectrum. While such models are typically unconstrained, consideration of spectral variability strongly restricts the allowed parameters, although to date the sampling has generally been too sparse to constrain the current models effectively. We investigate the time evolution of the inhomogeneous jet model for a simple perturbation propagating along the jet. The implications of this time evolution model and its relevance to observed data are discussed.
Time-dependent inhomogeneous jet models for BL Lac objects
NASA Astrophysics Data System (ADS)
Marlowe, A. T.; Urry, C. M.; George, I. M.
1992-05-01
Relativistic beaming can explain many of the observed properties of BL Lac objects (e.g., rapid variability, high polarization, etc.). In particular, the broadband radio through X-ray spectra are well modeled by synchrotron-self Compton emission from an inhomogeneous relativistic jet. We have done a uniform analysis on several BL Lac objects using a simple but plausible inhomogeneous jet model. For all objects, we found that the assumed power-law distribution of the magnetic field and the electron density can be adjusted to match the observed BL Lac spectrum. While such models are typically unconstrained, consideration of spectral variability strongly restricts the allowed parameters, although to date the sampling has generally been too sparse to constrain the current models effectively. We investigate the time evolution of the inhomogeneous jet model for a simple perturbation propagating along the jet. The implications of this time evolution model and its relevance to observed data are discussed.
RNA structure in splicing: An evolutionary perspective.
Lin, Chien-Ling; Taggart, Allison J; Fairbrother, William G
2016-09-01
Pre-mRNA splicing is a key post-transcriptional regulation process in which introns are excised and exons are ligated together. A novel class of structured intron was recently discovered in fish. Simple expansions of complementary AC and GT dimers at opposite boundaries of an intron were found to form a bridging structure, thereby enforcing correct splice site pairing across the intron. In some fish introns, the RNA structures are strong enough to bypass the need of regulatory protein factors for splicing. Here, we discuss the prevalence and potential functions of highly structured introns. In humans, structured introns usually arise through the co-occurrence of C and G-rich repeats at intron boundaries. We explore the potentially instructive example of the HLA receptor genes. In HLA pre-mRNA, structured introns flank the exons that encode the highly polymorphic β sheet cleft, making the processing of the transcript robust to variants that disrupt splicing factor binding. While selective forces that have shaped HLA receptor are fairly atypical, numerous other highly polymorphic genes that encode receptors contain structured introns. Finally, we discuss how the elevated mutation rate associated with the simple repeats that often compose structured intron can make structured introns themselves rapidly evolving elements.
NASA Technical Reports Server (NTRS)
Tenney, Yvette J.; Rogers, William H.; Pew, Richard W.
1995-01-01
There has been much concern in recent years about the rapid increase in automation on commercial flight decks. The survey was composed of three major sections. The first section asked pilots to rate different automation components that exist on the latest commercial aircraft regarding their obtrusiveness and the attention and effort required in using them. The second section addressed general 'automation philosophy' issues. The third section focused on issues related to levels and amount of automation. The results indicate that pilots of advanced aircraft like their automation, use it, and would welcome more automation. However, they also believe that automation has many disadvantages, especially fully autonomous automation. They want their automation to be simple and reliable and to produce predictable results. The biggest needs for higher levels of automation were in pre-flight, communication, systems management, and task management functions, planning as well as response tasks, and high workload situations. There is an irony and a challenge in the implications of these findings. On the one hand pilots would like new automation to be simple and reliable, but they need it to support the most complex part of the job--managing and planning tasks in high workload situations.
2013-01-01
Background High temperature stress responses are vital for plant survival. The mechanisms that plants use to sense high temperatures are only partially understood and involve multiple sensing and signaling pathways. Here we describe the development of the RootScope, an automated microscopy system for quantitating heat shock responses in plant roots. Results The promoter of Hsp17.6 was used to build a Hsp17.6p:GFP transcriptional reporter that is induced by heat shock in Arabidopsis. An automated fluorescence microscopy system which enables multiple roots to be imaged in rapid succession was used to quantitate Hsp17.6p:GFP response dynamics. Hsp17.6p:GFP signal increased with temperature increases from 28°C to 37°C. At 40°C the kinetics and localization of the response are markedly different from those at 37°C. This suggests that different mechanisms mediate heat shock responses above and below 37°C. Finally, we demonstrate that Hsp17.6p:GFP expression exhibits wave like dynamics in growing roots. Conclusions The RootScope system is a simple and powerful platform for investigating the heat shock response in plants. PMID:24119322
A Rapid and Simple Real-Time PCR Assay for Detecting Foodborne Pathogenic Bacteria in Human Feces.
Hanabara, Yutaro; Ueda, Yutaka
2016-11-22
A rapid, simple method for detecting foodborne pathogenic bacteria in human feces is greatly needed. Here, we examined the efficacy of a method that employs a combination of a commercial PCR master mix, which is insensitive to PCR inhibitors, and a DNA extraction method which used sodium dodecyl benzene sulfonate (SDBS), and Tween 20 to counteract the inhibitory effects of SDBS on the PCR assay. This method could detect the target genes (stx1 and stx2 of enterohemorrhagic Escherichia coli, invA of Salmonella Enteritidis, tdh of Vibrio parahaemolyticus, gyrA of Campylobacter jejuni, ceuE of Campylobacter coli, SEA of Staphylococcus aureus, ces of Bacillus cereus, and cpe of Clostridium perfringens) in a fecal suspension containing 1.0 × 10 1 to 1.0 × 10 3 CFU/ml. Furthermore, the assay was neither inhibited nor influenced by individual differences among the fecal samples of 10 subjects or fecal concentration (40-160 mg/ml in the fecal suspension). When we attempted to detect the genes of pathogenic bacteria in 4 actual clinical cases, we found that this method was more sensitive than standard culture method. These results showed that this assay is a rapid, simple detection method for foodborne pathogenic bacteria in human feces.
Viguet-Carrin, S; Gineyts, E; Bertholon, C; Delmas, P D
2009-01-01
A rapid high performance liquid chromatographic method was developed including an internal standard for the measurement of mature and senescent crosslinks concentration in non-demineralized bone hydrolysates. To avoid the demineralization which is a tedious step, we developed a method based on the use of a solid-phase extraction procedure to clean-up the samples. It resulted in sensitive and accurate measurements: the detection limits as low as 0.2 pmol for the pyridimium crosslinks and 0.02 pmol for the pentosidine. The inter- and intra-assay coefficients of variation were as low as 5% and 2%, respectively, for all crosslinks.
Miao, Yu; Wang, Cheng-long; Yin, Hui-jun; Shi, Da-zhuo; Chen, Ke-ji
2005-04-18
To establish method for the quantitative determination of adenosine phosphates in rat myocardium by optimized high performance liquid chromatogram (HPLC). ODS HYPERSIL C(18) column and a mobile phase of 50 mmol/L tribasic potassium phosphate buffer solution (pH 6.5), with UV detector at 254 nm were used. The average recovery rates of myocardial adenosine triphosphate (ATP), adenosine diphosphate (ADP) and adenosine monophosphate (AMP) were 99%-107%, 96%-104% and 95%-119%, respectively; relative standard deviations (RSDs) of within-day and between-days were less than 1.5% and 5.1%, respectively. The method is simple, rapid and accurate, and can be used to analyse the adenosine phosphates in myocardium.
Lin, Li-Rong; Luo, He-Dong; Li, Xiu-Ying; Li, Na; Zhou, Na; Jia, Yu-Zhu; Liu, Yi-Hong; Li, Yao-Qun
2014-01-01
Based on the high solubility efficiency and strong fluorescence response of benzo(a)pyrene (BaP) in dimethyl sulfoxide in combination with the high-performance derivative constant-energy synchronous fluorescence spectroscopic (DCESFS) technique, a simple, sensitive and economic method was developed for the determination of BaP in liquid milk. This method comprises ultrasound-assisted solvent extraction, solvent replacement and DCESFS detection. No saponification or other tedious clean-up procedures were needed. The recoveries of BaP in different milk samples were greater than 82%. Detection limits in full- and low-fat milk were 0.03 and 0.04 μg kg(-1), respectively.
David, Fabrice P A; Delafontaine, Julien; Carat, Solenne; Ross, Frederick J; Lefebvre, Gregory; Jarosz, Yohan; Sinclair, Lucas; Noordermeer, Daan; Rougemont, Jacques; Leleu, Marion
2014-01-01
The HTSstation analysis portal is a suite of simple web forms coupled to modular analysis pipelines for various applications of High-Throughput Sequencing including ChIP-seq, RNA-seq, 4C-seq and re-sequencing. HTSstation offers biologists the possibility to rapidly investigate their HTS data using an intuitive web application with heuristically pre-defined parameters. A number of open-source software components have been implemented and can be used to build, configure and run HTS analysis pipelines reactively. Besides, our programming framework empowers developers with the possibility to design their own workflows and integrate additional third-party software. The HTSstation web application is accessible at http://htsstation.epfl.ch.
HTSstation: A Web Application and Open-Access Libraries for High-Throughput Sequencing Data Analysis
David, Fabrice P. A.; Delafontaine, Julien; Carat, Solenne; Ross, Frederick J.; Lefebvre, Gregory; Jarosz, Yohan; Sinclair, Lucas; Noordermeer, Daan; Rougemont, Jacques; Leleu, Marion
2014-01-01
The HTSstation analysis portal is a suite of simple web forms coupled to modular analysis pipelines for various applications of High-Throughput Sequencing including ChIP-seq, RNA-seq, 4C-seq and re-sequencing. HTSstation offers biologists the possibility to rapidly investigate their HTS data using an intuitive web application with heuristically pre-defined parameters. A number of open-source software components have been implemented and can be used to build, configure and run HTS analysis pipelines reactively. Besides, our programming framework empowers developers with the possibility to design their own workflows and integrate additional third-party software. The HTSstation web application is accessible at http://htsstation.epfl.ch. PMID:24475057
Nicoletti, I; Corradini, C; Cogliandro, E; Cavazza, A
1999-08-01
This paper reports the results of a study carried out to develop a simple, rapid and sensitive method for the separation, identification and quantitative measurement of alpha-hydroxy acids in commercial cosmetics using high-performance liquid chromatography (HPLC). This method is successfully applied to the simultaneous identification and quantitative determination of glycolic, lactic, malic, tartaric and citric acids employing a reversed phase narrow-bore column under isocratic condition and UV detection. The method is validated by determining the precision of replicate analyses and accuracy by analyzing samples with and without adding know amount of the alpha-hydroxy acids. The procedure is suitable for routine analyses of commercial cosmetics.
Li, Hui; Lu, Dingqiang; Liu, Weimin
2004-05-01
A method for determining glycyrrhizinic acid in the biotransformation system by reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The HPLC conditions were as follows: Hypersil C18 column (4.6 mm i.d. x 250 mm, 5 microm) with a mixture of methanol-water-acetic acid (70:30:1, v/v) as the mobile phase; flow rate at 1.0 mL/min; and UV detection at 254 nm. The linear range of glycyrrhizinic acid was 0.2-20 microg. The recoveries were 98%-103% with relative standard deviations between 0.16% and 1.58% (n = 3). The method is simple, rapid and accurate for determining glycyrrhizinic acid.
Augmenting ejector endwall effects. [V/STOL aircraft
NASA Technical Reports Server (NTRS)
Porter, J. L.; Squyers, R. A.
1979-01-01
Rectangular inlet ejectors which had multiple hypermixing nozzles for their primary jets were investigated for the effects of endwall blowing on thrust augmentation performance. The ejector configurations tested had both straight wall and active boundary layer control type diffusers. Endwall flows were energized and controlled by simple blowing jets suitably located in the ejector. Both the endwall and boundary layer control diffuser blowing rates were varied to determine optimum performance. High area ratio diffusers with insufficient endwall blowing showed endwall separation and rapid degradation of thrust performance. Optimized values of diffuser boundary layer control and endwall nozzle blowing rates in an ejector augmenter were shown to achieve high levels of augmentation performance for maximum compactness.
Adaptive Process Controls and Ultrasonics for High Temperature PEM MEA Manufacture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walczyk, Daniel F.
2015-08-26
The purpose of this 5-year DOE-sponsored project was to address major process bottlenecks associated with fuel cell manufacturing. New technologies were developed to significantly reduce pressing cycle time for high temperature PEM membrane electrode assembly (MEA) through the use of novel, robust ultrasonic (U/S) bonding processes along with low temperature (<100°C) PEM MEAs. In addition, greater manufacturing uniformity and performance was achieved through (a) an investigation into the causes of excessive variation in ultrasonically and thermally bonded MEAs using more diagnostics applied during the entire fabrication and cell build process, and (b) development of rapid, yet simple quality control measurementmore » techniques for use by industry.« less
Wide-Field Imaging of Single-Nanoparticle Extinction with Sub-nm2 Sensitivity
NASA Astrophysics Data System (ADS)
Payne, Lukas M.; Langbein, Wolfgang; Borri, Paola
2018-03-01
We report on a highly sensitive wide-field imaging technique for quantitative measurement of the optical extinction cross section σext of single nanoparticles. The technique is simple and high speed, and it enables the simultaneous acquisition of hundreds of nanoparticles for statistical analysis. Using rapid referencing, fast acquisition, and a deconvolution analysis, a shot-noise-limited sensitivity down to 0.4 nm2 is achieved. Measurements on a set of individual gold nanoparticles of 5 nm diameter using this method yield σext=(10.0 ±3.1 ) nm2, which is consistent with theoretical expectations and well above the background fluctuations of 0.9 nm2 .
One-dimensional α-MoO3 nanorods for high energy density pseudocapacitor
NASA Astrophysics Data System (ADS)
Dutta, Shibsankar; Pal, Shreyasi; De, Sukanta
2018-04-01
Ultralong α-MoO3 nanorods having length of 500 nm to 1 µm and uniform width of around ˜50 nm have been synthesized by a simple one step hydrothermal route using a molybdenum organic salt precursor. An evaluation of the electrochemical properties of the nanorods was done by cyclic voltammetry (CV), and galvanometric charging- discharging (GCD) test. Because of the high active sites and rapid ion diffusion and electron transport of the electrodes using as prepared nanorods reveals energy density of 65 Wh/kg at a power density of 940 W/ kg and a maximum specific capacitance of 474 F/g. It also shows excellent cycling stability.
Nanjareddy, Kalpana; Arthikala, Manoj-Kumar; Blanco, Lourdes; Arellano, Elizabeth S; Lara, Miguel
2016-06-24
Phaseolus vulgaris is one of the most extensively studied model legumes in the world. The P. vulgaris genome sequence is available; therefore, the need for an efficient and rapid transformation system is more imperative than ever. The functional characterization of P. vulgaris genes is impeded chiefly due to the non-amenable nature of Phaseolus sp. to stable genetic transformation. Transient transformation systems are convenient and versatile alternatives for rapid gene functional characterization studies. Hence, the present work focuses on standardizing methodologies for protoplast isolation from multiple tissues and transient transformation protocols for rapid gene expression analysis in the recalcitrant grain legume P. vulgaris. Herein, we provide methodologies for the high-throughput isolation of leaf mesophyll-, flower petal-, hypocotyl-, root- and nodule-derived protoplasts from P. vulgaris. The highly efficient polyethylene glycol-mannitol magnesium (PEG-MMG)-mediated transformation of leaf mesophyll protoplasts was optimized using a GUS reporter gene. We used the P. vulgaris SNF1-related protein kinase 1 (PvSnRK1) gene as proof of concept to demonstrate rapid gene functional analysis. An RT-qPCR analysis of protoplasts that had been transformed with PvSnRK1-RNAi and PvSnRK1-OE vectors showed the significant downregulation and ectopic constitutive expression (overexpression), respectively, of the PvSnRK1 transcript. We also demonstrated an improved transient transformation approach, sonication-assisted Agrobacterium-mediated transformation (SAAT), for the leaf disc infiltration of P. vulgaris. Interestingly, this method resulted in a 90 % transformation efficiency and transformed 60-85 % of the cells in a given area of the leaf surface. The constitutive expression of YFP further confirmed the amenability of the system to gene functional characterization studies. We present simple and efficient methodologies for protoplast isolation from multiple P. vulgaris tissues. We also provide a high-efficiency and amenable method for leaf mesophyll transformation for rapid gene functional characterization studies. Furthermore, a modified SAAT leaf disc infiltration approach aids in validating genes and their functions. Together, these methods help to rapidly unravel novel gene functions and are promising tools for P. vulgaris research.
Evolution in an Afternoon: Rapid Natural Selection and Adaptation of Bacterial Populations
ERIC Educational Resources Information Center
Delpech, Roger
2009-01-01
This paper describes a simple, rapid and low-cost technique for growing bacteria (or other microbes) in an environmental gradient, in order to determine the tolerance of the microbial population to varying concentrations of sodium chloride ions, and suggests how the evolutionary response of a microbial population to the selection pressure of the…
Microbial Inactivation for Safe and Rapid Diagnostics of Infectious Samples ▿ †
Sagripanti, Jose-Luis; Hülseweh, Birgit; Grote, Gudrun; Voß, Luzie; Böhling, Katrin; Marschall, Hans-Jürgen
2011-01-01
The high risk associated with biological threat agents dictates that any suspicious sample be handled under strict surety and safety controls and processed under high-level containment in specialized laboratories. This study attempted to find a rapid, reliable, and simple method for the complete inactivation of a wide range of pathogens, including spores, vegetative bacteria, and viruses, while preserving microbial nucleic acid fragments suitable for PCRs and proteinaceous epitopes for detection by immunoassays. Formaldehyde, hydrogen peroxide, and guanidium thiocyanate did not completely inactivate high titers of bacterial spores or viruses after 30 min at 21°C. Glutaraldehyde and sodium hypochlorite showed high microbicidal activity but obliterated the PCR or enzyme-linked immunosorbent assay (ELISA) detection of bacterial spores or viruses. High-level inactivation (more than 6 log10) of bacterial spores (Bacillus atrophaeus), vegetative bacteria (Pseudomonas aeruginosa), an RNA virus (the alphavirus Pixuna virus), or a DNA virus (the orthopoxvirus vaccinia virus) was attained within 30 min at 21°C by treatment with either peracetic acid or cupric ascorbate with minimal hindrance of subsequent PCR tests and immunoassays. The data described here should provide the basis for quickly rendering field samples noninfectious for further analysis under lower-level containment and considerably lower cost. PMID:21856830
Xu, Bin; Zhang, Dong-Yang; Liu, Ze-Yu; Zhang, Ying; Liu, Li; Li, Long; Liu, Charles C; Wu, Guo-Hua
2015-10-10
A new method based on a Direct Analysis in Real Time (DART) ionization source coupled with triple quadrupole tandem mass spectrometry has been developed for rapid qualitative and quantitative analyses of 1-deoxynojirimycin (DNJ) in mulberry leaves. Two ions produced from DNJ, [M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162), are observed using DART-MS in the positive ion mode. The peak areas of the two selected ions monitoring (SIM) signals of ([M+H](+) (m/z 164) and [M-2H+H](+) (m/z 162)) are integrated to determine the peak area for quantitative analyses. A reasonable linear regression equation is obtained in the range of 1.01 to 40.50 μg/mL, with a linear coefficient (R(2)) of 0.996. The limits of detection (LOD) and quantification (LOQ) of the method are 0.25 and 0.80 μg/mL, respectively. The range of recovery is shown to be 87.73-95.61%. The results derived from the developed DART-MS method are in good agreement with those from the conventional HPLC-FLD method. By contrast, DART-MS in SIM mode is a simple, rapid and high-throughput approach for the determination of the DNJ content in mulberry leaves. The present method is advantageous for the rapid screening of mulberry leaves containing high DNJ contents. Copyright © 2015 Elsevier B.V. All rights reserved.
Agatonovic-Kustrin, Snezana; Morton, David W; Yusof, Ahmad P
2016-04-15
The aim of this study was to: (a) develop a simple, high performance thin layer chromatographic (HPTLC) method combined with direct 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay to rapidly assess and compare free radical scavenging activity or anti-oxidant activity for major classes of polyphenolics present in wines; and (b) to investigate relationship between free radical scavenging activity to the total polyphenolic content (TPC) and total antioxidant capacity (TAC) in the wine samples. The most potent free radical scavengers that we tested for in the wine samples were found to be resveratrol (polyphenolic non-flavonoid) and rutin (flavonoid), while polyphenolic acids (caffeic acid and gallic acid) although present in all wine samples were found to be less potent free radical scavengers. Therefore, the total antioxidant capacity was mostly affected by the presence of resveratrol and rutin, while total polyphenolic content was mostly influenced by the presence of the less potent free radical scavengers gallic and caffeic acids. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chang, A; Havas, S; Borellini, F; Ostrove, J M; Bird, R E
1997-12-01
During the manufacture of biopharmaceuticals, numerous adventitious agents have been detected in Master Cell Banks, end-of-production cells as well as bulk harvest fluid. Recently, a number of large-scale production bioreactors have become infected with Minute Virus of Mice (MVM) during cGMP (current good manufacturing practices) operations, and this has resulted in both the loss of product and the need for major cleaning validation procedures to be put in place. We have developed a simple DNA extraction/PCR assay to detect the presence of MVM in cell culture supernatant (conditioned cell fluids). This highly specific assay can detect 10 or fewer genome equivalents (copies) of MVM following PCR and gel electrophoresis visualization. For routine high-throughput detection, 300-100 copies could be consistently detected. The extraction procedure was shown to reliably detect MVM at a concentration of 1 TCID50/ml. The combination of the extraction/PCR procedure establishes a powerful, sensitive, specific assay that can detect the presence of MVM sequences with a 1-day turnaround time.
NASA Astrophysics Data System (ADS)
Kim, Yong-Hyun; Kim, Ki-Hyun
2015-07-01
The analysis of polycyclic aromatic hydrocarbons (PAH) in ambient air requires the tedious experimental steps of both sampling and pretreatment (e.g., extraction or clean-up). To replace pre-existing conventional methods, a simple, rapid, and novel technique was developed to measure gas-particle fractionation of PAH in ambient air based on ‘sorbent tube-thermal desorption-gas chromatograph-mass spectrometer (ST-TD-GC-MS)’. The separate collection and analysis of ambient PAHs were achieved independently by two serially connected STs. The basic quality assurance confirmed good linearity, precision, and high sensitivity to eliminate the need for complicated pretreatment procedures with the detection limit (16 PAHs: 13.1 ± 7.04 pg). The analysis of real ambient PAH samples showed a clear fractionation between gas (two-three ringed PAHs) and particulate phases (five-six ringed PAHs). In contrast, for intermediate (four ringed) PAHs (fluoranthene, pyrene, benz[a]anthracene, and chrysene), a highly systematic/gradual fractionation was established. It thus suggests a promising role of ST-TD-GC-MS as measurement system in acquiring a reliable database of airborne PAH.
Mariño-Repizo, Leonardo; Goicoechea, Hector; Raba, Julio; Cerutti, Soledad
2018-06-07
A novel, simple, easy and cheap sample treatment strategy based on salting-out assisted liquid-liquid extraction (SALLE) for ochratoxin A (OTA) ultra-trace analysis in beer samples using ultra-high performance liquid chromatography-tandem mass spectrometry determination was developed. The factors involved in the efficiency of pretreatment were studied employing factorial design in the screening phase and the optimal conditions of the significant variables on the analytical response were evaluated using a central composite face-centred design (CCF). Consequently, the amount of salt ((NH 4 ) 2 SO 4 ), together with the volumes of sample, hydrophilic (acetone) and nonpolar (toluene) solvents, and times of vortexing and centrifugation were optimized. Under optimized conditions, the limits of detection (LOD) and quantification (LOQ) were 0.02 µg l -1 and 0.08 µg l -1 respectively. OTA extraction recovery by SALLE was approximately 90% (0.2 µg l -1 ). Furthermore, the methodology was in agreement with EU Directive requirements and was successfully applied for analysis of beer samples.
A rapid and highly selective method for the estimation of pyro-, tri- and orthophosphates.
Kamat, D R; Savant, V V; Sathyanarayana, D N
1995-03-01
A rapid, highly selective and simple method has been developed for the quantitative determination of pyro-, tri- and orthophosphates. The method is based on the formation of a solid complex of bis(ethylenediamine)cobalt(III) species with pyrophosphate at pH 4.2-4.3, with triphosphate at pH 2.0-2.1 and with orthophosphate at pH 8.2-8.6. The proposed method for pyro- and triphosphates differs from the available method, which is based on the formation of an adduct with tris(ethylenediamine)cobalt(III) species. The complexes have the composition [Co(en)(2)HP(2)O(7)]4H(2)O and [Co(en)(2)H(2)P(3)O(10)]2H(2)O, respectively. The precipitation is instantaneous and quantitative under the recommended optimum conditions giving 99.5% gravimetric yield in both cases. There is no interferences from orthophosphate, trimetaphosphate and pyrophosphate species in the triphosphate estimation up to 5% of each component. The efficacy of the method has been established by determining pyrophosphate and triphosphate contents in various matrices. In the case of orthophosphate, the proposed method differs from the available methods such as ammonium phosphomolybdate, vanadophosphomolybdate and quinoline phosphomolybdate, which are based on the formation of a precipitate, followed by either titrimetry or gravimetry. The precipitation is instantaneous and the method is simple. Under the recommended pH and other reaction conditions, gravimetric yields of 99.6-100% are obtainable. The method is applicable to orthophosphoric acid and a variety of phosphate salts.
A Simple Experiment for Visualizing Diffusion
ERIC Educational Resources Information Center
Helseth, L. E.
2011-01-01
We propose a simple and fascinating experiment for studying diffusion in gels using a pH-sensitive dye. By doping agar with methyl red, we obtain a gel which rapidly reacts to changes in pH by changing its absorption spectrum. The pH gradients can be followed using a digital camera, and we demonstrate here that the pH-sensitive colour changes can…
2012-01-01
Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence. PMID:22452821
Lederer, W J
1983-09-01
A device is described that is capable of rapidly moving microelectrodes and micropipettes over distances up to 15 mu. This piezoelectric transLator uses the diaphragm from virtually any available piezoelectric buzzer in combination with simple physical support and drive electronics. All of the necessary details for the construction of this small device are presented. Each finished unit is about 2 cm long with a diameter of 2 cm and can be readily adapted to existing manipulators. The translator has been found useful in aiding the independent penetration by one or more microelectrodes of single cells or of more complicated multicellular preparations (including those that lie behind a connective tissue layer). This new device offers fine control of microelectrode motion that cannot be obtained by the other methods used to aid microelectrode and micropipette penetration of cell membranes (e.g. capacitance overcompensation--"ringing in"' or "tickling"--or tapping the manipulator base). Finally, the device described in this paper is extremely simple and inexpensive to build.
Oh, Se Yeon
2018-05-01
Aroma is important in night-flowering species, as visually they can not be observed well. Thus, the analysis of the volatiles of evening-primrose is of great interest in biological fields and therapy. Furthermore, the analysis of volatiles demands rapid and simple procedure, because volatiles decompose. The aim of this study is to show the rapid monitoring of the volatiles of evening-primrose according to the flowering or closing by fast gas chromatography/surface acoustic wave GC/SAW. Moreover, calibration according to the sensor temperature of the GC/SAW was performed, achieving a high reproducibility and excellent sensitivity. GC/SAW is an effective analytical method that provides on-line measurements without pretreatment of sample. Headspace solid-phase micro-extraction coupled to gas chromatography mass spectrometry (HS-SPME-GC-MS) and dynamic headspace trapping and extraction with GC-MS were employed to confirm the identification of the volatiles of evening-primrose compared to GC/SAW. Linalool was found to be the dominant component, comprising 96.4-25.2% of the total amount, according to the opening or closing. Interestingly, the amount of indole also varied according to the opening or closing (3.0-0.0%) such as linalool. Also, while the sensitivity increased with the reduction in the sensor temperature of the GC/SAW, the reproducibility showed a tendency to decrease. The results showed that flower opening is related to the volatiles emission, which is pharmacological and plant defensive. GC/SAW can be a useful analytical method for the rapid monitoring of volatiles of evening-primrose according to the opening or closing as it provides second unit analysis, as well as simple, and aroma pattern recognition. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Rapid and label-free detection of protein a by aptamer-tethered porous silicon nanostructures.
Urmann, Katharina; Reich, Peggy; Walter, Johanna-Gabriela; Beckmann, Dieter; Segal, Ester; Scheper, Thomas
2017-09-10
Protein A, which is secreted by and displayed on the cell membrane of Staphylococcus aureus is an important biomarker for S. aureus. Thus, its rapid and specific detection may facilitate the pathogen identification and initiation of proper treatment. Herein, we present a simple, label-free and rapid optical biosensor enabling specific detection of protein A. Protein A-binding aptamer serves as the capture probe and is immobilized onto a nanostructured porous silicon thin film, which serves as the optical transducer element. We demonstrate high sensitivity of the biosensor with a linear detection range between 8 and 23μM. The apparent dissociation constant was determined as 13.98μM and the LoD is 3.17μM. Harnessing the affinity between protein A and antibodies, a sandwich assay format was developed to amplify the optical signal associated with protein A capture by the aptamer. Using this approach, we increase the sensitivity of the biosensor, resulting in a three times lower LoD. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ugai, Hideyo; Yamasaki, Takahito; Hirose, Megumi
2005-06-17
Adenoviruses are excellent vectors for gene transfer and are used extensively for high-level expression of the products of transgenes in living cells. The development of simple and rapid methods for the purification of stable infectious recombinant adenoviruses (rAds) remains a challenge. We report here a method for the purification of infectious adenovirus type 5 (Ad5) that involves ultracentrifugation on a cesium chloride gradient at 604,000g for 15 min at 4 deg C and tangential flow filtration. The entire procedure requires less than two hours and infectious Ad5 can be recovered at levels higher than 64% of the number of plaque-formingmore » units (pfu) in the initial crude preparation of viruses. We have obtained titers of infectious purified Ad5 of 1.35 x 10{sup 10} pfu/ml and a ratio of particle titer to infectious titer of seven. The method described here allows the rapid purification of rAds for studies of gene function in vivo and in vitro, as well as the rapid purification of Ad5.« less
Mouse Sperm Cryopreservation and Recovery of Genetically Modified Mice.
Low, Benjamin E; Taft, Rob A; Wiles, Michael V
2016-01-01
Highly definable genetically, the humble mouse is the "reagent" mammal of choice with which to probe and begin to understand the human condition in all its complexities. With the recent advance in direct genome editing via targeted nucleases, e.g., TALEN and CRISPR/Cas9, the possibilities in using these sophisticated tools have increased substantially leading to a massive increase in the variety of strain numbers of genetically modified lines. With this increase comes a greater need to economically and creatively manage their numbers. Further, once characterized, lines may be of limited use but still need to be archived in a format allowing their rapid resurrection. Further, maintaining colonies on "the shelf" is financially draining and carries potential risks including natural disaster loss, disease, and strain contamination. Here we outline a simple and economic protocol to cryopreserve mouse sperm from many different genetic backgrounds, and outline its recovery via in vitro fertilization (IVF). The combined use of sperm cryopreservation and IVF now allows a freedom and versatility in mouse management facilitating rapid line close down with the option to later recover and rapidly expand as needed.
Zhu, H B; Su, C J; Tang, H F; Ruan, Z; Liu, D H; Wang, H; Qian, Y L
2017-10-20
Objective: To establish a method for rapid determination of 47 volatile organic compounds in the air of workplace using portable gas chromatography - mass spectrometer(GC - MS). Methods: The mixed standard gas with different concentration levels was made by using the static gas distribution method with the high purity nitrogen as dilution gas. The samples were injected into the GC - MS by a hand - held probe. Retention time and characteristic ion were used for qualitative analysis,and the internal standard method was usd for quantitation. Results: The 47 poisonous substances were separated and determined well. The linear range of this method was 0.2 - 16.0 mg/m(3),and the relative standard deviation of 45 volatile ovganic compounds was 3.8% - 15.8%. The average recovery was 79.3% - 119.0%. Conclusion: The method is simple,accurate,sensitive,has good separation effect,short analysis period, can be used for qualitative and quantitative analysis of volatile organic compounds in the workplace, and also supports the rapid identification and detection of occupational hazards.
Rapid Screening of Ergot Alkaloids in Sclerotia by MALDI-TOF Mass Spectrometry.
Sivagnanam, Kumaran; Komatsu, Emy; Patrick, Susan; Rampitsch, Christoph; Perreault, Hélène; Gräfenhan, Tom
2016-07-01
Ergot is a common disease of wheat and other cereal grains that is predominantly caused by Claviceps purpurea in the field, often affecting crop yield in addition to the environment. Infected grain can be contaminated with dark sclerotia, which contain fungal metabolites such as ergot alkaloids. The occurrence of ergot alkaloids in cereal grain is a major health concern for humans and livestock. Effective and rapid screening of these mycotoxins is crucial for producers, processors, and consumers of cereal-based food and feed grain. Established methods of ergot alkaloid screening based on LC-MS or GC-MS require laborious processes. A novel method using matrix-assisted laser desorption ionization (MALDI)-time-of-flight (TOF) MS was developed to identify four ergot alkaloids. Using dihydroxybenzoic acid as the matrix, ergosine, ergocornine, ergocryptine, and ergocristine were readily detected in individual sclerotia of C. purpurea. The accuracy of the identified ergot alkaloids was further confirmed by tandem MS analysis. MALDI-TOF MS is suitable for high-throughput screening of ergot alkaloids because it permits rapid and accurate identification, simple sample preparation, and no derivatization or chromatographic separation.
Nanocolloidal gold-based immuno-dip strip assay for rapid detection of Sudan red I in food samples.
Wang, Jia; Wang, Zhanhui; Liu, Jing; Li, Hao; Li, Qing X; Li, Ji; Xu, Ting
2013-02-15
A semiquantitative dip strip assay was developed using nanocolloidal gold-labelled monoclonal antibody (Mab) 8A10 for the rapid detection of Sudan red I in food samples. A protein-Sudan red I conjugate was coated on a nitro cellulose membrane strip in a defined test line. In flow of the complex of nanocolloidal gold labelled-Mab and Sudan red I along the strip, intensive red colour that was formed in the test line reflected the Sudan red I concentration. The test required 10 min and had a visual limit of detection of 10 ng/g Sudan red I in tomato sauce and chilli powder samples. The results of the strip assay agreed well with those of a high performance liquid chromatography method for both spiked and real commercial samples. The strip was stable for at least 2 months at 4°C. The strip assay offers the potential as a useful rapid and simple method for screening of Sudan red I in food samples. Copyright © 2012 Elsevier Ltd. All rights reserved.
Raman spectroscopy on simple molecular systems at very high density
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiferl, D.; LeSar, R.S.; Moore, D.S.
1988-01-01
We present an overview of how Raman spectroscopy is done on simple molecular substances at high pressures. Raman spectroscopy is one of the most powerful tools for studying these substances. It is often the quickest means to explore changes in crystal and molecular structures, changes in bond strength, and the formation of new chemical species. Raman measurements have been made at pressures up to 200 GPa (2 Mbar). Even more astonishing is the range of temperatures (4-5200/degree/K) achieved in various static and dynamic (shock-wave) pressure experiments. One point we particularly wish to emphasize is the need for a good theoreticalmore » understanding to properly interpret and use experimental results. This is particularly true at ultra-high pressures, where strong crystal field effects can be misinterpreted as incipient insulator-metal transitions. We have tried to point out apparatus, techniques, and results that we feel are particularly noteworthy. We have also included some of the /open quotes/oral tradition/close quotes/ of high pressure Raman spectroscopy -- useful little things that rarely or never appear in print. Because this field is rapidly expanding, we discuss a number of exciting new techniques that have been informally communicated to us, especially those that seem to open new possibilities. 58 refs., 18 figs.« less
Matityahu, Shlomi; Emuna, Moran; Yahel, Eyal; Makov, Guy; Greenberg, Yaron
2015-04-01
We present a novel experimental design for high sensitivity measurements of the electrical resistance of samples at high pressures (0-6 GPa) and high temperatures (300-1000 K) in a "Paris-Edinburgh" type large volume press. Uniquely, the electrical measurements are carried out directly on a small sample, thus greatly increasing the sensitivity of the measurement. The sensitivity to even minor changes in electrical resistance can be used to clearly identify phase transitions in material samples. Electrical resistance measurements are relatively simple and rapid to execute and the efficacy of the present experimental design is demonstrated by measuring the electrical resistance of Pb, Sn, and Bi across a wide domain of temperature-pressure phase space and employing it to identify the loci of phase transitions. Based on these results, the phase diagrams of these elements are reconstructed to high accuracy and found to be in excellent agreement with previous studies. In particular, by mapping the locations of several well-studied reference points in the phase diagram of Sn and Bi, it is demonstrated that a standard calibration exists for the temperature and pressure, thus eliminating the need for direct or indirect temperature and pressure measurements. The present technique will allow simple and accurate mapping of phase diagrams under extreme conditions and may be of particular importance in advancing studies of liquid state anomalies.
Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei
2017-01-01
In Cannabis sativa L., tetrahydrocannabinol (THC) is the primary psychoactive compound and exists as the carboxylated form, tetrahydrocannabinolic acid (THCA). C. sativa is divided into two strains based on THCA content-THCA-rich (drug-type) strains and THCA-poor (fiber-type) strains. Both strains are prohibited by law in many countries including Japan, whereas the drug-type strains are regulated in Canada and some European countries. As the two strains cannot be discriminated by morphological analysis, a simple method for identifying the drug-type strains is required for quality control in legal cultivation and forensic investigation. We have developed a novel loop-mediated isothermal amplification (LAMP) assay for identifying the drug-type strains of C. sativa. We designed two selective LAMP primer sets for on-site or laboratory use, which target the drug-type THCA synthase gene. The LAMP assay was accomplished within approximately 40 min. The assay showed high specificity for the drug-type strains and its sensitivity was the same as or higher than that of conventional polymerase chain reaction. We also showed the effectiveness of melting curve analysis that was conducted after the LAMP assay. The melting temperature values of the drug-type strains corresponded to those of the cloned drug-type THCA synthase gene, and were clearly different from those of the cloned fiber-type THCA synthase gene. Moreover, the LAMP assay with simple sample preparation could be accomplished within 1 h from sample treatment to identification without the need for special devices or techniques. Our rapid, sensitive, specific, and simple assay is expected to be applicable to laboratory and on-site detection.
Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L
2017-06-01
Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.
NASA Astrophysics Data System (ADS)
Cavanaugh, C.; Gille, J.; Francis, G.; Nardi, B.; Hannigan, J.; McInerney, J.; Krinsky, C.; Barnett, J.; Dean, V.; Craig, C.
2005-12-01
The High Resolution Dynamics Limb Sounder (HIRDLS) instrument onboard the NASA Aura spacecraft experienced a rupture of the thermal blanketing material (Kapton) during the rapid depressurization of launch. The Kapton draped over the HIRDLS scan mirror, severely limiting the aperture through which HIRDLS views space and Earth's atmospheric limb. In order for HIRDLS to achieve its intended measurement goals, rapid characterization of the anomaly, and rapid recovery from it were required. The recovery centered around a new processing module inserted into the standard HIRDLS processing scheme, with a goal of minimizing the effect of the anomaly on the already existing processing modules. We describe the software infrastructure on which the new processing module was built, and how that infrastructure allows for rapid application development and processing response. The scope of the infrastructure spans three distinct anomaly recovery steps and the means for their intercommunication. Each of the three recovery steps (removing the Kapton-induced oscillation in the radiometric signal, removing the Kapton signal contamination upon the radiometric signal, and correcting for the partially-obscured atmospheric view) is completely modularized and insulated from the other steps, allowing focused and rapid application development towards a specific step, and neutralizing unintended inter-step influences, thus greatly shortening the design-development-test lifecycle. The intercommunication is also completely modularized and has a simple interface to which the three recovery steps adhere, allowing easy modification and replacement of specific recovery scenarios, thereby heightening the processing response.
Detection of influenza A virus subtypes using a solid-phase PCR microplate chip assay.
Sun, Xin-Cheng; Wang, YunLong; Yang, Liping; Zhang, HuiRu
2015-01-01
A rapid and sensitive microplate chip based on solid PCR was developed to identify influenza A subtypes. A simple ultraviolet cross-linking method was used to immobilize DNA probes on pretreated microplates. Solid-phase PCR was proven to be a convenient method for influenza A screening. The sensitivity of the microplate chip was 10(-3) μg/mL for the enzymatic colorimetric method and 10(-4) μg/mL for the fluorescence method. The 10 sets of primers and probes for the microplate chip were highly specific and did not interfere with each other. These results suggest that the microplate chip based on solid PCR can be used to rapidly detect universal influenza A and its subtypes. This platform can also be used to detect other pathogenic microorganisms. Copyright © 2014 Elsevier B.V. All rights reserved.
Food quality inspection by speckle decorrelation properties of bacteria colonies
NASA Astrophysics Data System (ADS)
Bianco, V.; Mandracchia, B.; Nazzaro, F.; Marchesano, V.; Gennari, O.; Paturzo, M.; Grilli, S.; Ferraro, P.
2017-06-01
The development of tools for rapid food quality inspection is a highly pursued goal. These could be valuable devices to be used by food producers in factories or the customers themselves in specific installations at the marketplace. Here we show how speckle patterns in coherent imaging systems can be can be employed as indicators of the presence of bacteria colonies contaminating food or water. Speckle decorrelation is induced by the self-propelling movement of these organisms when they interact with coherent light. Hence, their presence can be detected using a simple setup in a condition in which the single element cannot be imaged, but the properties of the ensemble can be exploited. Thanks to the small magnification factor we set, our system can inspect a large Field-of-View (FoV). We show the possibility to discriminate between fresh and contaminated food, thus paving the way to the rapid food quality testing by consumers at the marketplace.
DNA assembler, an in vivo genetic method for rapid construction of biochemical pathways
Shao, Zengyi; Zhao, Hua; Zhao, Huimin
2009-01-01
The assembly of large recombinant DNA encoding a whole biochemical pathway or genome represents a significant challenge. Here, we report a new method, DNA assembler, which allows the assembly of an entire biochemical pathway in a single step via in vivo homologous recombination in Saccharomyces cerevisiae. We show that DNA assembler can rapidly assemble a functional d-xylose utilization pathway (∼9 kb DNA consisting of three genes), a functional zeaxanthin biosynthesis pathway (∼11 kb DNA consisting of five genes) and a functional combined d-xylose utilization and zeaxanthin biosynthesis pathway (∼19 kb consisting of eight genes) with high efficiencies (70–100%) either on a plasmid or on a yeast chromosome. As this new method only requires simple DNA preparation and one-step yeast transformation, it represents a powerful tool in the construction of biochemical pathways for synthetic biology, metabolic engineering and functional genomics studies. PMID:19074487
NASA Astrophysics Data System (ADS)
Li, Shikuo; Shen, Yuhua; Xie, Anjian; Yu, Xuerong; Zhang, Xiuzhen; Yang, Liangbao; Li, Chuanhao
2007-10-01
We describe the formation of amorphous selenium (α-Se)/protein composites using Capsicum annuum L extract to reduce selenium ions (SeO32-) at room temperature. The reaction occurs rapidly and the process is simple and easy to handle. A protein with a molecular weight of 30 kDa extracted from Capsicum annuum L not only reduces the SeO32- ions to Se0, but also controls the nucleation and growth of Se0, and even participates in the formation of α-Se/protein composites. The size and shell thickness of the α-Se/protein composites increases with high Capsicum annuum L extract concentration, and decreases with low reaction solution pH. The results suggest that this eco-friendly, biogenic synthesis strategy could be widely used for preparing inorganic/organic biocomposites. In addition, we also discuss the possible mechanism of the reduction of SeO32- ions by Capsicum annuum L extract.
A rapid liquid chromatography determination of free formaldehyde in cod.
Storey, Joseph M; Andersen, Wendy C; Heise, Andrea; Turnipseed, Sherri B; Lohne, Jack; Thomas, Terri; Madson, Mark
2015-01-01
A rapid method for the determination of free formaldehyde in cod is described. It uses a simple water extraction of formaldehyde which is then derivatised with 2,4-dinitrophenylhydrazine (DNPH) to form a sensitive and specific chromophore for high-performance liquid chromatography (HPLC) detection. Although this formaldehyde derivative has been widely used in past tissue analysis, this paper describes an improved derivatisation procedure. The formation of the DNPH formaldehyde derivative has been shortened to 2 min and a stabilising buffer has been added to the derivative to increase its stability. The average recovery of free formaldehyde in spiked cod was 63% with an RSD of 15% over the range of 25-200 mg kg(-1) (n = 48). The HPLC procedure described here was also compared to a commercial qualitative procedure - a swab test for the determination of free formaldehyde in fish. Several positive samples were compared by both methods.
Digital detection of endonuclease mediated gene disruption in the HIV provirus
Sedlak, Ruth Hall; Liang, Shu; Niyonzima, Nixon; De Silva Feelixge, Harshana S.; Roychoudhury, Pavitra; Greninger, Alexander L.; Weber, Nicholas D.; Boissel, Sandrine; Scharenberg, Andrew M.; Cheng, Anqi; Magaret, Amalia; Bumgarner, Roger; Stone, Daniel; Jerome, Keith R.
2016-01-01
Genome editing by designer nucleases is a rapidly evolving technology utilized in a highly diverse set of research fields. Among all fields, the T7 endonuclease mismatch cleavage assay, or Surveyor assay, is the most commonly used tool to assess genomic editing by designer nucleases. This assay, while relatively easy to perform, provides only a semi-quantitative measure of mutation efficiency that lacks sensitivity and accuracy. We demonstrate a simple droplet digital PCR assay that quickly quantitates a range of indel mutations with detection as low as 0.02% mutant in a wild type background and precision (≤6%CV) and accuracy superior to either mismatch cleavage assay or clonal sequencing when compared to next-generation sequencing. The precision and simplicity of this assay will facilitate comparison of gene editing approaches and their optimization, accelerating progress in this rapidly-moving field. PMID:26829887
Rapid Detection of Ricin in Serum Based on Cu-Chelated Magnetic Beads Using Mass Spectrometry.
Zhao, Yong-Qiang; Song, Jian; Wang, Hong-Li; Xu, Bin; Liu, Feng; He, Kun; Wang, Na
2016-04-01
The protein toxin ricin obtained from castor bean plant (Ricinus communis) seeds is a potent biological warfare agent due to its ease of availability and acute toxicity. In this study, we demonstrated a rapid and simple method to detect ricin in serum in vitro. The ricin was mixed with serum and digested by trypsin, then all the peptides were efficiently extracted using Cu-chelated magnetic beads and were detected with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The specific ricin peptides were identified by Nanoscale Ultra Performance liquid chromatography coupled to tandem mass spectrometry according to their sequences. The assay required 2.5 hours, and a characteristic peptide could be detected down to 4 ng/μl and used as a biomarker to detect ricin in serum. The high sensitivity and simplicity of the procedure makes it valuable in clinical practice. Graphical Abstract ᅟ.
Rapid Detection of Ricin in Serum Based on Cu-Chelated Magnetic Beads Using Mass Spectrometry
NASA Astrophysics Data System (ADS)
Zhao, Yong-Qiang; Song, Jian; Wang, Hong-Li; Xu, Bin; Liu, Feng; He, Kun; Wang, Na
2016-04-01
The protein toxin ricin obtained from castor bean plant (Ricinus communis) seeds is a potent biological warfare agent due to its ease of availability and acute toxicity. In this study, we demonstrated a rapid and simple method to detect ricin in serum in vitro. The ricin was mixed with serum and digested by trypsin, then all the peptides were efficiently extracted using Cu-chelated magnetic beads and were detected with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The specific ricin peptides were identified by Nanoscale Ultra Performance liquid chromatography coupled to tandem mass spectrometry according to their sequences. The assay required 2.5 hours, and a characteristic peptide could be detected down to 4 ng/μl and used as a biomarker to detect ricin in serum. The high sensitivity and simplicity of the procedure makes it valuable in clinical practice.
Speech target modulates speaking induced suppression in auditory cortex
Ventura, Maria I; Nagarajan, Srikantan S; Houde, John F
2009-01-01
Background Previous magnetoencephalography (MEG) studies have demonstrated speaking-induced suppression (SIS) in the auditory cortex during vocalization tasks wherein the M100 response to a subject's own speaking is reduced compared to the response when they hear playback of their speech. Results The present MEG study investigated the effects of utterance rapidity and complexity on SIS: The greatest difference between speak and listen M100 amplitudes (i.e., most SIS) was found in the simple speech task. As the utterances became more rapid and complex, SIS was significantly reduced (p = 0.0003). Conclusion These findings are highly consistent with our model of how auditory feedback is processed during speaking, where incoming feedback is compared with an efference-copy derived prediction of expected feedback. Thus, the results provide further insights about how speech motor output is controlled, as well as the computational role of auditory cortex in transforming auditory feedback. PMID:19523234
Cell-Free Optogenetic Gene Expression System.
Jayaraman, Premkumar; Yeoh, Jing Wui; Jayaraman, Sudhaghar; Teh, Ai Ying; Zhang, Jingyun; Poh, Chueh Loo
2018-04-20
Optogenetic tools provide a new and efficient way to dynamically program gene expression with unmatched spatiotemporal precision. To date, their vast potential remains untapped in the field of cell-free synthetic biology, largely due to the lack of simple and efficient light-switchable systems. Here, to bridge the gap between cell-free systems and optogenetics, we studied our previously engineered one component-based blue light-inducible Escherichia coli promoter in a cell-free environment through experimental characterization and mathematical modeling. We achieved >10-fold dynamic expression and demonstrated rapid and reversible activation of the target gene to generate oscillatory response. The deterministic model developed was able to recapitulate the system behavior and helped to provide quantitative insights to optimize dynamic response. This in vitro optogenetic approach could be a powerful new high-throughput screening technology for rapid prototyping of complex biological networks in both space and time without the need for chemical induction.
Exciton-controlled fluorescence: application to hybridization-sensitive fluorescent DNA probe.
Okamoto, Akimitsu; Ikeda, Shuji; Kubota, Takeshi; Yuki, Mizue; Yanagisawa, Hiroyuki
2009-01-01
A hybridization-sensitive fluorescent probe has been designed for nucleic acid detection, using the concept of fluorescence quenching caused by the intramolecular excitonic interaction of fluorescence dyes. We synthesized a doubly thiazole orange-labeled nucleotide showing high fluorescence intensity for a hybrid with the target nucleic acid and effective quenching for the single-stranded state. This exciton-controlled fluorescent probe was applied to living HeLa cells using microinjection to visualize intracellular mRNA localization. Immediately after injection of the probe into the cell, fluorescence was observed from the probe hybridizing with the target RNA. This fluorescence rapidly decreased upon addition of a competitor DNA. Multicoloring of this probe resulted in the simple simultaneous detection of plural target nucleic acid sequences. This probe realized a large, rapid, reversible change in fluorescence intensity in sensitive response to the amount of target nucleic acid, and facilitated spatiotemporal monitoring of the behavior of intracellular RNA.
Rapid, Vehicle-Based Identification of Location and Magnitude of Urban Natural Gas Pipeline Leaks.
von Fischer, Joseph C; Cooley, Daniel; Chamberlain, Sam; Gaylord, Adam; Griebenow, Claire J; Hamburg, Steven P; Salo, Jessica; Schumacher, Russ; Theobald, David; Ham, Jay
2017-04-04
Information about the location and magnitudes of natural gas (NG) leaks from urban distribution pipelines is important for minimizing greenhouse gas emissions and optimizing investment in pipeline management. To enable rapid collection of such data, we developed a relatively simple method using high-precision methane analyzers in Google Street View cars. Our data indicate that this automated leak survey system can document patterns in leak location and magnitude within and among cities, even without wind data. We found that urban areas with prevalent corrosion-prone distribution lines (Boston, MA, Staten Island, NY, and Syracuse, NY), leaked approximately 25-fold more methane than cities with more modern pipeline materials (Burlington, VT, and Indianapolis, IN). Although this mobile monitoring method produces conservative estimates of leak rates and leak counts, it can still help prioritize both leak repairs and replacement of leak-prone sections of distribution lines, thus minimizing methane emissions over short and long terms.
Rapid Surface Functionalization of Hydrogen-Terminated Silicon by Alkyl Silanols.
Escorihuela, Jorge; Zuilhof, Han
2017-04-26
Surface functionalization of inorganic semiconductor substrates, particularly silicon, has focused attention toward many technologically important applications, involving photovoltaic energy, biosensing and catalysis. For such modification processes, oxide-free (H-terminated) silicon surfaces are highly required, and different chemical approaches have been described in the past decades. However, their reactivity is often poor, requiring long reaction times (2-18 h) or the use of UV light (10-30 min). Here, we report a simple and rapid surface functionalization for H-terminated Si(111) surfaces using alkyl silanols. This catalyst-free surface reaction is fast (15 min at room temperature) and can be accelerated with UV light irradiation, reducing the reaction time to 1-2 min. This grafting procedure leads to densely packed organic monolayers that are hydrolytically stable (even up to 30 days at pH 3 or 11) and can display excellent antifouling behavior against a range of organic polymers.
Rapid Surface Functionalization of Hydrogen-Terminated Silicon by Alkyl Silanols
2017-01-01
Surface functionalization of inorganic semiconductor substrates, particularly silicon, has focused attention toward many technologically important applications, involving photovoltaic energy, biosensing and catalysis. For such modification processes, oxide-free (H-terminated) silicon surfaces are highly required, and different chemical approaches have been described in the past decades. However, their reactivity is often poor, requiring long reaction times (2–18 h) or the use of UV light (10–30 min). Here, we report a simple and rapid surface functionalization for H-terminated Si(111) surfaces using alkyl silanols. This catalyst-free surface reaction is fast (15 min at room temperature) and can be accelerated with UV light irradiation, reducing the reaction time to 1–2 min. This grafting procedure leads to densely packed organic monolayers that are hydrolytically stable (even up to 30 days at pH 3 or 11) and can display excellent antifouling behavior against a range of organic polymers. PMID:28409624
Huo, Ya-Yun; Li, Gui-Fen; Qiu, Yan-Hong; Li, Wei-Min; Zhang, Yong-Jiang
2017-11-23
Prunus necrotic ringspot virus (PNRSV) is one of the most devastating viruses to Prunus spp. In this study, we developed a diagnostic system RT-CPA-NATSC, wherein reverse transcription-cross-priming amplification (RT-CPA) is coupled with nucleic acid test strip cassette (NATSC), a vertical flow (VF) visualization, for PNRSV detection. The RT-CPA-NATSC assay targets the encoding gene of the PNRSV coat protein with a limit of detection of 72 copies per reaction and no cross-reaction with the known Prunus pathogenic viruses and viroids, demonstrating high sensitivity and specificity. The reaction is performed on 60 °C and can be completed less than 90 min with the prepared template RNA. Field sample test confirmed the reliability of RT-CPA-NATSC, indicating the potential application of this simple and rapid detection method in routine test of PNRSV.
NASA Astrophysics Data System (ADS)
Jha, Rajveer; Higashinaka, Ryuji; Matsuda, Tatsuma D.; Ribeiro, Raquel A.; Aoki, Yuji
2018-05-01
We report on a systematic study of Hall effect using high quality single crystals of type-II Weyl semimetal WTe2 with the applied magnetic field B//c. The residual resistivity ratio of 1330 and the large magnetoresistance of 1.5 × 106 % in 9 T at 2 K, being in the highest class in the literature, attest to their high quality. Based on a simple two-carrier model, the densities (ne and nh) and mobilities (μe and μh) for electron and hole carriers have been uniquely determined combining both Hall- and electrical-resistivity data. The difference between ne and nh is 1% at 2 K, indicating that the system is in an compensated condition. The negative Hall resistivity growing rapidly below 20 K is due to a rapidly increasing μh/μe approaching one. Below 3 K in a low field region, we found the Hall resistivity becomes positive, reflecting that μh/μe finally exceeds one in this region. These anomalous behaviors of the carrier densities and mobilities might be associated with the existence of a Lifshitz transition and/or the spin texture on the Fermi surface.
Recent advances in salivary cancer diagnostics enabled by biosensors and bioelectronics.
Mishra, Saswat; Saadat, Darius; Kwon, Ohjin; Lee, Yongkuk; Choi, Woon-Seop; Kim, Jong-Hoon; Yeo, Woon-Hong
2016-07-15
There is a high demand for a non-invasive, rapid, and highly accurate tool for disease diagnostics. Recently, saliva based diagnostics for the detection of specific biomarkers has drawn significant attention since the sample extraction is simple, cost-effective, and precise. Compared to blood, saliva contains a similar variety of DNA, RNA, proteins, metabolites, and microbiota that can be compiled into a multiplex of cancer detection markers. The salivary diagnostic method holds great potential for early-stage cancer diagnostics without any complicated and expensive procedures. Here, we review various cancer biomarkers in saliva and compare the biomarkers efficacy with traditional diagnostics and state-of-the-art bioelectronics. We summarize biomarkers in four major groups: genomics, transcriptomics, proteomics, and metabolomics/microbiota. Representative bioelectronic systems for each group are summarized based on various stages of a cancer. Systematic study of oxidative stress establishes the relationship between macromolecules and cancer biomarkers in saliva. We also introduce the most recent examples of salivary diagnostic electronics based on nanotechnologies that can offer rapid, yet highly accurate detection of biomarkers. A concluding section highlights areas of opportunity in the further development and applications of these technologies. Copyright © 2016 Elsevier B.V. All rights reserved.
Design of PID temperature control system based on STM32
NASA Astrophysics Data System (ADS)
Zhang, Jianxin; Li, Hailin; Ma, Kai; Xue, Liang; Han, Bianhua; Dong, Yuemeng; Tan, Yue; Gu, Chengru
2018-03-01
A rapid and high-accuracy temperature control system was designed using proportional-integral-derivative (PID) control algorithm with STM32 as micro-controller unit (MCU). The temperature control system can be applied in the fields which have high requirements on the response speed and accuracy of temperature control. The temperature acquisition circuit in system adopted Pt1000 resistance thermometer as temperature sensor. Through this acquisition circuit, the monitoring actual temperature signal could be converted into voltage signal and transmitted into MCU. A TLP521-1 photoelectric coupler was matched with BD237 power transistor to drive the thermoelectric cooler (TEC) in FTA951 module. The effective electric power of TEC was controlled by the pulse width modulation (PWM) signals which generated by MCU. The PWM signal parameters could be adjusted timely by PID algorithm according to the difference between monitoring actual temperature and set temperature. The upper computer was used to input the set temperature and monitor the system running state via serial port. The application experiment results show that the temperature control system is featured by simple structure, rapid response speed, good stability and high temperature control accuracy with the error less than ±0.5°C.
High-throughput flow alignment of barcoded hydrogel microparticles†
Chapin, Stephen C.; Pregibon, Daniel C.
2010-01-01
Suspension (particle-based) arrays offer several advantages over conventional planar arrays in the detection and quantification of biomolecules, including the use of smaller sample volumes, more favorable probe-target binding kinetics, and rapid probe-set modification. We present a microfluidic system for the rapid alignment of multifunctional hydrogel microparticles designed to bear one or several biomolecule probe regions, as well as a graphical code to identify the embedded probes. Using high-speed imaging, we have developed and optimized a flow-through system that (1) allows for a high particle throughput, (2) ensures proper particle alignment for decoding and target quantification, and (3) can be reliably operated continuously without clogging. A tapered channel flanked by side focusing streams is used to orient the flexible, tablet-shaped particles into a well-ordered flow in the center of the channel. The effects of channel geometry, particle geometry, particle composition, particle loading density, and barcode design are explored to determine the best combination for eventual use in biological assays. Particles in the optimized system move at velocities of ~50 cm s−1 and with throughputs of ~40 particles s−1. Simple physical models and CFD simulations have been used to investigate flow behavior in the device. PMID:19823726
Kanlaya, Rattiyaporn; Thongboonkerd, Visith
2016-08-01
Conventional method to purify/concentrate dengue virus (DENV) is time-consuming with low virus recovery yield. Herein, we applied cellufine sulfate column chromatography to purify/concentrate DENV based on the mimicry between heparan sulfate and DENV envelope protein. Comparative analysis demonstrated that this new method offered higher purity (as determined by less contamination of bovine serum albumin) and recovery yield (as determined by greater infectivity). Moreover, overall duration used for cellufine sulfate column chromatography to purify/concentrate DENV was approximately 1/20 of that of conventional method. Therefore, cellufine sulfate column chromatography serves as a simple, rapid, and effective alternative method for DENV purification/concentration. Copyright © 2016 Elsevier B.V. All rights reserved.
Pírez, Macarena; Gonzalez-Sapienza, Gualberto; Sienra, Daniel; Ferrari, Graciela; Last, Michael; Last, Jerold A; Brena, Beatriz M
2013-01-15
In recent years, the international demand for commodities has prompted enormous growth in agriculture in most South American countries. Due to intensive use of fertilizers, cyanobacterial blooms have become a recurrent phenomenon throughout the continent, but their potential health risk remains largely unknown due to the lack of analytical capacity. In this paper we report the main results and conclusions of more than five years of systematic monitoring of cyanobacterial blooms in 20 beaches of Montevideo, Uruguay, on the Rio de la Plata, the fifth largest basin in the world. A locally developed microcystin ELISA was used to establish a sustainable monitoring program that revealed seasonal peaks of extremely high toxicity, more than one-thousand-fold greater than the WHO limit for recreational water. Comparison with cyanobacterial cell counts and chlorophyll-a determination, two commonly used parameters for indirect estimation of toxicity, showed that such indicators can be highly misleading. On the other hand, the accumulated experience led to the definition of a simple criterion for visual classification of blooms, that can be used by trained lifeguards and technicians to take rapid on-site decisions on beach management. The simple and low cost approach is broadly applicable to risk assessment and risk management in developing countries. Copyright © 2012 Elsevier Ltd. All rights reserved.
The endomembrane requirement for cell surface repair
NASA Technical Reports Server (NTRS)
McNeil, Paul L.; Miyake, Katsuya; Vogel, Steven S.
2003-01-01
The capacity to reseal a plasma membrane disruption rapidly is required for cell survival in many physiological environments. Intracellular membrane (endomembrane) is thought to play a central role in the rapid resealing response. We here directly compare the resealing response of a cell that lacks endomembrane, the red blood cell, with that of several nucleated cells possessing an abundant endomembrane compartment. RBC membrane disruptions inflicted by a mode-locked Ti:sapphire laser, even those initially smaller than hemoglobin, failed to reseal rapidly. By contrast, much larger laser-induced disruptions made in sea urchin eggs, fibroblasts, and neurons exhibited rapid, Ca(2+)-dependent resealing. We conclude that rapid resealing is not mediated by simple physiochemical mechanisms; endomembrane is required.
Sergueev, Kirill V; He, Yunxiu; Borschel, Richard H; Nikolich, Mikeljon P; Filippov, Andrey A
2010-06-28
Yersinia pestis, the agent of plague, has caused many millions of human deaths and still poses a serious threat to global public health. Timely and reliable detection of such a dangerous pathogen is of critical importance. Lysis by specific bacteriophages remains an essential method of Y. pestis detection and plague diagnostics. The objective of this work was to develop an alternative to conventional phage lysis tests--a rapid and highly sensitive method of indirect detection of live Y. pestis cells based on quantitative real-time PCR (qPCR) monitoring of amplification of reporter Y. pestis-specific bacteriophages. Plague diagnostic phages phiA1122 and L-413C were shown to be highly effective diagnostic tools for the detection and identification of Y. pestis by using qPCR with primers specific for phage DNA. The template DNA extraction step that usually precedes qPCR was omitted. phiA1122-specific qPCR enabled the detection of an initial bacterial concentration of 10(3) CFU/ml (equivalent to as few as one Y. pestis cell per 1-microl sample) in four hours. L-413C-mediated detection of Y. pestis was less sensitive (up to 100 bacteria per sample) but more specific, and thus we propose parallel qPCR for the two phages as a rapid and reliable method of Y. pestis identification. Importantly, phiA1122 propagated in simulated clinical blood specimens containing EDTA and its titer rise was detected by both a standard plating test and qPCR. Thus, we developed a novel assay for detection and identification of Y. pestis using amplification of specific phages monitored by qPCR. The method is simple, rapid, highly sensitive, and specific and allows the detection of only live bacteria.
Muniroh, M S; Sariah, M; Zainal Abidin, M A; Lima, N; Paterson, R R M
2014-05-01
Detection of basal stem rot (BSR) by Ganoderma of oil palms was based on foliar symptoms and production of basidiomata. Enzyme-Linked Immunosorbent Assays-Polyclonal Antibody (ELISA-PAB) and PCR have been proposed as early detection methods for the disease. These techniques are complex, time consuming and have accuracy limitations. An ergosterol method was developed which correlated well with the degree of infection in oil palms, including samples growing in plantations. However, the method was capable of being optimised. This current study was designed to develop a simpler, more rapid and efficient ergosterol method with utility in the field that involved the use of microwave extraction. The optimised procedure involved extracting a small amount of Ganoderma, or Ganoderma-infected oil palm suspended in low volumes of solvent followed by irradiation in a conventional microwave oven at 70°C and medium high power for 30s, resulting in simultaneous extraction and saponification. Ergosterol was detected by thin layer chromatography (TLC) and quantified using high performance liquid chromatography with diode array detection. The TLC method was novel and provided a simple, inexpensive method with utility in the field. The new method was particularly effective at extracting high yields of ergosterol from infected oil palm and enables rapid analysis of field samples on site, allowing infected oil palms to be treated or culled very rapidly. Some limitations of the method are discussed herein. The procedures lend themselves to controlling the disease more effectively and allowing more effective use of land currently employed to grow oil palms, thereby reducing pressure to develop new plantations. Copyright © 2014 Elsevier B.V. All rights reserved.
Perspectives on the rapid eye movement sleep switch in rapid eye movement sleep behavior disorder.
Ramaligam, Vetrivelan; Chen, Michael C; Saper, Clifford B; Lu, Jun
2013-08-01
Rapid eye movement (REM) sleep in mammals is associated with wakelike cortical and hippocampal activation and concurrent postural muscle atonia. Research during the past 5 decades has revealed the details of the neural circuitry regulating REM sleep and muscle atonia during this state. REM-active glutamatergic neurons in the sublaterodorsal nucleus (SLD) of the dorsal pons are critical for generation for REM sleep atonia. Descending projections from SLD glutamatergic neurons activate inhibitory premotor neurons in the ventromedial medulla (VMM) and in the spinal cord to antagonize the glutamatergic supraspinal inputs on the motor neurons during REM sleep. REM sleep behavior disorder (RBD) consists of simple behaviors (i.e., twitching, jerking) and complex behaviors (i.e., defensive behavior, talking). Animal research has lead to the hypothesis that complex behaviors in RBD are due to SLD pathology, while simple behaviors of RBD may be due to less severe SLD pathology or dysfunction of the VMM, ventral pons, or spinal cord. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tang, Lijun; He, Ping; Zhong, Keli; Hou, Shuhua; Bian, Yanjiang
2016-12-01
A new reactive probe, 1-(benzo[d]thiazol-2-yl)naphthalen-2-yl-picolinate (BTNP), was designed and synthesized. BTNP acts as a highly selective probe to Cu2 + in DMSO/H2O (7/3, v/v, Tris-HCl 10 mM, pH = 7.4) solution based on Cu2 + catalyzed hydrolysis of the picolinate ester moiety in BTNP, which leads to the formation of an ESIPT active product with dual wavelength emission enhancement. The probe also possesses the advantages of simple synthesis, rapid response and high sensitivity. The pseudo-first-order reaction rate constant was calculated to be 0.205 min- 1. Moreover, application of BTNP to Cu2 + detection in living cells and real water samples was also explored.
Hu, J-Y; Deng, Z-B; Qin, D-M
2009-12-01
JS-118 is a diacylhydrazines-type insect growth regulator used extensively in China now. An analytical method for residues determination of JS-118 in cabbage and soil samples by high performance liquid chromatography with DAD detection was established and optimized. Primary secondary amine solid phase extraction cartridge was used for sample preparation. Mean recoveries for the analyte ranged from 96.6% to 107.0% with CV value less than 4.7%. The limit of quantification is 0.01 mg/kg. Direct confirmation of JS-118 residues in samples was realized by high performance liquid chromatography-mass spectrometry. The proposed method is simple, rapid and reliable to perform and could be utilized for monitoring of pesticides residues.
Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?
Chouler, Jon; Di Lorenzo, Mirella
2015-01-01
The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries. PMID:26193327
A Novel High-Efficiency Rear-Contact Solar Cell with Bifacial Sensitivity
NASA Astrophysics Data System (ADS)
Hezel, R.
At present, wafer-based silicon solar cells have a share of more than 90% of the photovoltaic market. Despite rapid growth in the manufacturing volume, accompanied by a significant drop in the module selling price, the high costs currently associated with photovoltaic power generation are one of the most important obstacles to widespread global use of solar electricity. Up to a certain level, a higher production volume is a key driver in cost reduction. However, apart from a drastic reduction of the silicon wafer thickness in conjunction with improved light-trapping schemes, innovative processing sequences combining very high solar cell efficiencies with simple and cost-effective fabrication techniques are needed to become competitive with conventional energy sources and thus to move solar energy from niche to mainstream.
Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?
Chouler, Jon; Di Lorenzo, Mirella
2015-07-16
The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries.
Oplatowska, Michalina; Stevenson, Paul J; Schulz, Claudia; Hartig, Lutz; Elliott, Christopher T
2011-09-01
Sudan dyes have been found to be added to chilli and chilli products for illegal colour enhancement purposes. Due to the possible carcinogenic effect, they are not authorized to be used in food in the European Union or the USA. However, over the last few years, many products imported from Asian and African countries have been reported via the Rapid Alert System for Food and Feed in the European Union to be contaminated with these dyes. In order to provide fast screening method for the detection of Sudan I (SI), which is the most widely abused member of Sudan dyes family, a unique (20 min without sample preparation) direct disequilibrium enzyme-linked immunosorbent assay (ELISA) was developed. The assay was based on polyclonal antibodies highly specific to SI. A novel, simple gel permeation chromatography clean-up method was developed to purify extracts from matrices containing high amounts of fat and natural pigments, without the need for a large dilution of the sample. The assay was validated according to the Commission Decision 2002/657/EC criteria. The detection capability was determined to be 15 ng g(-1) in sauces and 50 ng g(-1) in spices. The recoveries found ranged from 81% to 116% and inter- and intra-assay coefficients of variation from 6% to 20%. The assay was used to screen a range of products (85 samples) collected from different retail sources within and outside the European Union. Three samples were found to contain high amounts (1,649, 722 and 1,461 ng g(-1)) of SI by ELISA. These results were confirmed by liquid chromatography-tandem mass spectrometry method. The innovative procedure allows for the fast, sensitive and high throughput screening of different foodstuffs for the presence of the illegal colorant SI.
Denmark, Scott E.; Marlin, John E.; Rajendra, G.
2012-01-01
The carbanion-accelerated Claisen rearrangement has been extended to include phosphorus carbanion-stabilizing groups. The appropriately substituted allyl vinyl ethers are synthesized by the nucleophilic addition of allyloxides to phosphorus-substituted allenes, which are obtained in one step from simple starting materials. The phosphorus-stabilized, carbanion-accelerated Claisen rearrangements proceed rapidly at room temperature in high yield, and the rearrangements are highly site and stereoselective. The first examples of asymmetric induction in the Claisen rearrangement with chiral, phosphorus, anion-stabilizing groups are described. The observed asymmetric induction is highly dependent on the structure of the auxiliary and the metal counterion involved. Both internal and relative diastereoselectivity are high. A model for the observed sense of internal diastereoselectivity is proposed that is founded in the current understanding of the structure of phosphorus-stabilized anions. PMID:23101563
Kim, C S; Lee, C H; Shin, J S; Chung, Y S; Hyung, N I
1997-03-01
Because DNA degradation is mediated by secondary plant products such as phenolic terpenoids, the isolation of high quality DNA from plants containing a high content of polyphenolics has been a difficult problem. We demonstrate an easy extraction process by modifying several existing ones. Using this process we have found it possible to isolate DNAs from four fruit trees, grape (Vitis spp.), apple (Malus spp.), pear (Pyrus spp.) and persimmon (Diospyros spp.) and four species of conifer, Pinus densiflora, Pinus koraiensis,Taxus cuspidata and Juniperus chinensis within a few hours. Compared with the existing method, we have isolated high quality intact DNAs (260/280 = 1.8-2.0) routinely yielding 250-500 ng/microl (total 7.5-15 microg DNA from four to five tissue discs).
Kim, C S; Lee, C H; Shin, J S; Chung, Y S; Hyung, N I
1997-01-01
Because DNA degradation is mediated by secondary plant products such as phenolic terpenoids, the isolation of high quality DNA from plants containing a high content of polyphenolics has been a difficult problem. We demonstrate an easy extraction process by modifying several existing ones. Using this process we have found it possible to isolate DNAs from four fruit trees, grape (Vitis spp.), apple (Malus spp.), pear (Pyrus spp.) and persimmon (Diospyros spp.) and four species of conifer, Pinus densiflora, Pinus koraiensis,Taxus cuspidata and Juniperus chinensis within a few hours. Compared with the existing method, we have isolated high quality intact DNAs (260/280 = 1.8-2.0) routinely yielding 250-500 ng/microl (total 7.5-15 microg DNA from four to five tissue discs). PMID:9023124
Intra, J; Sala, M R; Falbo, R; Cappellini, F; Brambilla, P
2016-12-01
Rapid and early identification of micro-organisms in blood has a key role in the diagnosis of a febrile patient, in particular, in guiding the clinician to define the correct antibiotic therapy. This study presents a simple and very fast method with high performances for identifying bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) after only 4 h of incubation. We used early bacterial growth on PolyViteX chocolate agar plates inoculated with five drops of blood-broth medium deposited in the same point and spread with a sterile loop, followed by a direct transfer procedure on MALDI-TOF MS target slides without additional modification. Ninety-nine percentage of aerobic bacteria were correctly identified from 600 monomicrobial-positive blood cultures. This procedure allowed obtaining the correct identification of fastidious pathogens, such as Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae that need complex nutritional and environmental requirements in order to grow. Compared to the traditional pathogen identification from blood cultures that takes over 24 h, the reliability of results, rapid performance and suitability of this protocol allowed a more rapid administration of optimal antimicrobial treatment in the patients. Bloodstream infections are serious conditions with a high mortality and morbidity rate. Rapid identification of pathogens and appropriate antimicrobial therapy have a key role for successful patient outcome. In this work, we developed a rapid, simplified, accurate, and efficient method, reaching 99 % identification of aerobic bacteria from monomicrobial-positive blood cultures by using early growth on enriched medium, direct transfer to target plate without additional procedures, matrix-assisted laser desorption ionization-time of flight mass spectrometry and SARAMIS database. The application of this protocol allows to anticipate appropriate antibiotic therapy. © 2016 The Society for Applied Microbiology.
A novel strategy for rapid detection of NT-proBNP
NASA Astrophysics Data System (ADS)
Cui, Qiyao; Sun, Honghao; Zhu, Hui
2017-09-01
In order to establish a simple, rapid, sensitive, and specific quantitative assay to detect the biomarkers of heart failure, in this study, biotin-streptavidin technology was employed with fluorescence immunochromatographic assay to detect the concentration of the biomarkers in serum, and this method was applied to detect NT-proBNP, which is valuable for diagnostic evaluation of heart failure.
USDA-ARS?s Scientific Manuscript database
A simple, rapid and sensitive immunogold chromatographic strip test based on a monoclonal antibody was developed for the detection of melamine (MEL) residues in raw milk, milk products and animal feed. The limit of detection was estimated to be 0.05 µg/mL in raw milk, since the detection test line ...
A centrifugal method for the evaluation of polymer membranes for reverse osmosis
NASA Technical Reports Server (NTRS)
Hollahan, J. R.; Wydeven, T.; Mccullough, R. P.
1973-01-01
A rapid and simple method employing the laboratory centrifuge shows promise for evaluation of membrane performance during reverse osmosis. Results are presented for cellulose acetate membranes for rejection of salt and urea dissolved solids. Implications of the study are to rapid screening of membrane performance, use in laboratories with limited facilities, and possible space waste water purification.
Nikoleli, Georgia-Paraskevi; Nikolelis, Dimitrios P; Methenitis, Constantinos
2010-08-18
This work describes the construction of a simple optical sensor for the rapid, selective and sensitive detection of urea in milk using air stable lipid films with incorporated urease. The lipid film is stabilized on a glass filter by polymerization using UV (ultra-violet) radiation prior its use. Methacrylic acid was the functional monomer, ethylene glycol dimethacrylate was the crosslinker and 2,2'-azobis-(2-methylpropionitrile) was the initiator. Urease is incorporated within this mixture prior to the polymerization. The presence of the enzyme in these films quenched this fluorescence and the colour became similar to that of the filters without the lipid films. A drop of aqueous solution of urea provided a "switching on" of the fluorescence which allows the rapid detection of this compound at the levels of 10(-8) M concentrations. The investigation of the effect of potent interferences included a wide range of compounds usually found in foods and also of proteins and lipids. These lipid membranes were used for the rapid detection of urea in milk. Copyright 2010 Elsevier B.V. All rights reserved.
Barbano, Duane; Diaz, Regina; Zhang, Lin; Sandrin, Todd; Gerken, Henri; Dempster, Thomas
2015-01-01
Current molecular methods to characterize microalgae are time-intensive and expensive. Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) may represent a rapid and economical alternative approach. The objectives of this study were to determine whether MALDI-TOF MS can be used to: 1) differentiate microalgae at the species and strain levels and 2) characterize simple microalgal mixtures. A common protein extraction sample preparation method was used to facilitate rapid mass spectrometry-based analysis of 31 microalgae. Each yielded spectra containing between 6 and 56 peaks in the m/z 2,000 to 20,000 range. The taxonomic resolution of this approach appeared higher than that of 18S rDNA sequence analysis. For example, two strains of Scenedesmus acutus differed only by two 18S rDNA nucleotides, but yielded distinct MALDI-TOF mass spectra. Mixtures of two and three microalgae yielded relatively complex spectra that contained peaks associated with members of each mixture. Interestingly, though, mixture-specific peaks were observed at m/z 11,048 and 11,230. Our results suggest that MALDI-TOF MS affords rapid characterization of individual microalgae and simple microalgal mixtures. PMID:26271045
Removal of iron and manganese using biological roughing up flow filtration technology.
Pacini, Virginia Alejandra; María Ingallinella, Ana; Sanguinetti, Graciela
2005-11-01
The removal of iron and manganese from groundwater using biological treatment methods is almost unknown in Latin America. Biological systems used in Europe are based on the process of double rapid biofiltration during which dissolved oxygen and pH need to be strictly controlled in order to limit abiotic iron oxidation. The performance of roughing filter technology in a biological treatment process for the removal of iron and manganese, without the use of chemical agents and under natural pH conditions was studied. Two pilot plants, using two different natural groundwaters, were operated with the following treatment line: aeration, up flow roughing filtration and final filtration (either slow or rapid). Iron and manganese removal efficiencies were found to be between 85% and 95%. The high solid retention capability of the roughing filter means that it is possible to remove iron and manganese simultaneously by biotic and abiotic mechanisms. This system combines simple, low-cost operation and maintenance with high iron and manganese removal efficiencies, thus constituting a technology which is particularly suited to small waterworks.
Yun, Huan; Liu, Xin; Cui, Jie; Yang, Jing; Liu, Ying
2017-08-08
A method for screening of acidity regulators in dairy based on ion chromatography-high resolution mass spectrometry technology (IC-HRMS) was set up. The dairy samples were extracted by KOH (pH 7-8) and Oasis MAX SPE column, and separated by a Dionex IonPac AS11-HC column (250 mm×4 mm). All the acidity regulators were detected by Orbitrap full scan mode. Taking six organic acids as an example, the calibration curves showed good linearities in the range of 0.05-5.00 mg/L, and the correlation coefficients ( r ) were higher than 0.99. By detecting the spiked samples, the recoveries were in the range of 74.3%-115.5% with the relative standard deviations (RSDs) between 0.64% and 4.81%. Malic acid, citric acid, lactic acid, succinic acid and adipic acid could be detected by IC-HRMS in the commercial dairy samples. The results indicate that the method is simple, rapid and suitable for the qualitative screening of acidity regulators in dairy products.
NASA Astrophysics Data System (ADS)
Wadzinski, Tyler J.; Steinauer, Angela; Hie, Liana; Pelletier, Guillaume; Schepartz, Alanna; Miller, Scott J.
2018-06-01
Glycosylated natural products and synthetic glycopeptides represent a significant and growing source of biochemical probes and therapeutic agents. However, methods that enable the aqueous glycosylation of endogenous amino acid functionality in peptides without the use of protecting groups are scarce. Here, we report a transformation that facilitates the efficient aqueous O-glycosylation of phenolic functionality in a wide range of small molecules, unprotected tyrosine, and tyrosine residues embedded within a range of complex, fully unprotected peptides. The transformation, which uses glycosyl fluoride donors and is promoted by Ca(OH)2, proceeds rapidly at room temperature in water, with good yields and selective formation of unique anomeric products depending on the stereochemistry of the glycosyl donor. High functional group tolerance is observed, and the phenol glycosylation occurs selectively in the presence of virtually all side chains of the proteinogenic amino acids with the singular exception of Cys. This method offers a highly selective, efficient, and operationally simple approach for the protecting-group-free synthesis of O-aryl glycosides and Tyr-O-glycosylated peptides in water.
Raran-Kurussi, Sreejith; Waugh, David S
2017-01-01
Rapid advances in bioengineering and biotechnology over the past three decades have greatly facilitated the production of recombinant proteins in Escherichia coli. Affinity-based methods that employ protein or peptide based tags for protein purification have been instrumental in this progress. Yet insolubility of recombinant proteins in E. coli remains a persistent problem. One way around this problem is to fuse an aggregation-prone protein to a highly soluble partner. E. coli maltose-binding protein (MBP) is widely acknowledged as a highly effective solubilizing agent. In this chapter, we describe how to construct either a His 6 - or a dual His 6 -MBP tagged fusion protein by Gateway ® recombinational cloning and how to evaluate their yield and solubility. We also describe a simple and rapid procedure to test the solubility of proteins after removing their N-terminal fusion tags by tobacco etch virus (TEV) protease digestion. The choice of whether to use a His 6 tag or a His 6 -MBP tag can be made on the basis of this solubility test.
Analysis of volatile compounds by open-air ionization mass spectrometry.
Meher, Anil Kumar; Chen, Yu-Chie
2017-05-08
This study demonstrates a simple method for rapid and in situ identification of volatile and endogenous compounds in culinary spice samples through mass spectrometry (MS). This method only requires a holder for solid spice sample (2-3 mm) that is placed close to a mass spectrometer inlet, which is applied with a high voltage. Volatile species responsible for the aroma of the spice samples can be readily detected by the mass spectrometer. Sample pretreatment is not required prior to MS analysis, and no solvent was used during MS analysis. The high voltage applied to the inlet of the mass spectrometer induces the ionization of volatile compounds released from the solid spice samples. Furthermore, moisture in the air also contributes to the ionization of volatile compounds. Dried spices including cinnamon and cloves are used as the model sample to demonstrate this straightforward MS analysis, which can be completed within few seconds. Furthermore, we also demonstrate the suitability of the current method for rapid screening of cinnamon quality through detection of the presence of a hepatotoxic agent, i.e. coumarin. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Guang; Li, Jun; Sun, Zhiwei; Zhang, Shijuan; Li, Guoliang; Song, Cuihua; Suo, Yourui; You, Jinmao
2014-01-15
Amino acids, as the main contributors to taste, are usually found in relatively high levels in bitter foods. In this work, we focused on seeking a rapid, sensitive and simple method to determine FAA for large batches of micro-samples and to explore the relationship between FAA and bitterness. Overall condition optimisation indicated that the new UDME technique offered higher derivatisation yields and extraction efficiencies than traditional methods. Only 35min was needed in the whole operation process. Very low LLOQ (Lower limit of quantification: 0.21-5.43nmol/L) for FAA in twelve bitter foods was obtained, with which BTT (bitter taste thresholds) and CABT (content of FAA at BTT level) were newly determined. The ratio of CABT to BTT increased with decreasing of BTT. This work provided powerful potential for the high-throughput trace analysis of micro-sample and also a methodology to study the relationship between the chemical constituents and the taste. Copyright © 2013 Elsevier Ltd. All rights reserved.
Using Depth Recovery in Humans
1988-07-07
presence of oriented luminance discontinuities or "edges" in the image data (Marr & Poggio, i976; Dey, 1975; Nelson, 1975 & 1977; Marr, Palm & Poggio, 1978...primitives, namely computational expense, is rapidly diminishing as we continue to benefit from dramatic advances in signal processing hardware...dimensional weighting function of simple cells are well fitted by Gabor functions. Pollen & Ronner (1981) demonstrated that simple cells which are tuned to
Van Berkel, Gary J.; Kertesz, Vilmos
2015-08-25
RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creatingmore » a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.« less
Streak Imaging Flow Cytometer for Rare Cell Analysis.
Balsam, Joshua; Bruck, Hugh Alan; Ossandon, Miguel; Prickril, Ben; Rasooly, Avraham
2017-01-01
There is a need for simple and affordable techniques for cytology for clinical applications, especially for point-of-care (POC) medical diagnostics in resource-poor settings. However, this often requires adapting expensive and complex laboratory-based techniques that often require significant power and are too massive to transport easily. One such technique is flow cytometry, which has great potential for modification due to the simplicity of the principle of optical tracking of cells. However, it is limited in that regard due to the flow focusing technique used to isolate cells for optical detection. This technique inherently reduces the flow rate and is therefore unsuitable for rapid detection of rare cells which require large volume for analysis.To address these limitations, we developed a low-cost, mobile flow cytometer based on streak imaging. In our new configuration we utilize a simple webcam for optical detection over a large area associated with a wide-field flow cell. The new flow cell is capable of larger volume and higher throughput fluorescence detection of rare cells than the flow cells with hydrodynamic focusing used in conventional flow cytometry. The webcam is an inexpensive, commercially available system, and for fluorescence analysis we use a 1 W 450 nm blue laser to excite Syto-9 stained cells with emission at 535 nm. We were able to detect low concentrations of stained cells at high flow rates of 10 mL/min, which is suitable for rapidly analyzing larger specimen volumes to detect rare cells at appropriate concentration levels. The new rapid detection capabilities, combined with the simplicity and low cost of this device, suggest a potential for clinical POC flow cytometry in resource-poor settings associated with global health.
Kolosova, Anna Yu; Sibanda, Liberty; Dumoulin, Frédéric; Lewis, Janet; Duveiller, Etienne; Van Peteghem, Carlos; De Saeger, Sarah
2008-06-02
A lateral-flow immunoassay using a colloidal gold-labelled monoclonal antibody was developed for the rapid detection of deoxynivalenol (DON). Different parameters, such as the amount of immunoreagents, type of the materials, composition of the blocking solution and of the detector reagent mixture, were investigated to provide the optimum assay performance. The experimental results demonstrated that such a visual test had an indicator range rather than a cut-off value. Thus, tests for DON determination with two different indicator ranges of 250-500 and 1000-2000 microg kg(-1) were designed. The method allowed detection of DON at low and high concentration levels, which could be useful for research and practical purposes. The assay applied to spiked wheat and pig feed samples demonstrated accurate and reproducible results. The applicability of the developed lateral-flow test was also confirmed under real field conditions. The test strips prepared in Belgium were sent to Mexico, where they were used for the screening of DON contamination in different bread wheat entries from Fusarium Head Blight inoculated plots. The results were compared with those obtained by ELISA and LC-MS/MS. A poor correlation between ELISA and LC-MS/MS was observed. Visual results of the dipstick tests were in a good agreement with the results of the LC-MS/MS method. Coupled with a simple and fast sample preparation, this qualitative one-step test based on the visual evaluation of results did not require any equipment. Results could be obtained within 10 min. The described assay format can be used as a simple, rapid, cost-effective and robust on-site screening tool for mycotoxin contamination in different agricultural commodities.
Tatebe, Chiye; Zhong, Xining; Ohtsuki, Takashi; Kubota, Hiroki; Sato, Kyoko; Akiyama, Hiroshi
2014-09-01
A simple and rapid high-performance liquid chromatography (HPLC) method to determine basic colorants such as pararosaniline (PA), auramine O (AO), and rhodamine B (RB) in various processed foods was developed. Linearity of the calibration curves ranged from 0.05 to 50 μg/mL for PA and 0.05-100 μg/mL for AO and RB. The detection and quantification limits (LOD and LOQ) of the basic colorants, which were evaluated as signal-to-noise ratios of 3 for LOD and 10 for LOQ, ranged from 0.0125 to 0.05 and 0.025 to 0.125 μg/g, respectively. The recoveries and relative standard deviations of three basic colorants in six processed foods, namely, chili sauce, curry paste, gochujang (hot pepper paste), tandoori chicken (roasted chicken prepared with yogurt and spices), powder soup, and shrimp powder ranged from 70.2% to 102.8% and 0.8% to 8.0%, respectively. The intraday precision of the recovery test ranged from 1.7% to 4.5%, whereas the interday precision ranged from 3.7% to 7.7%. The reported method has been successfully applied to basic colorant determination in various processed foods such as fat-based food matrices (curry paste and tandoori chicken), chili products (gochujang and chili sauce), and protein-based products (shrimp powder and powder soup). Thin layer chromatography and liquid chromatography/mass spectrometry methods for the determination of basic colorants in processed foods were also developed for rapid analysis and identification, respectively. These methods are very useful for monitoring unauthorized basic colorants in inspection centers or quarantine laboratories in many countries.
Xu, Chun-Xiu; Yin, Xue-Feng
2011-02-04
A chip-based microfluidic system for high-throughput single-cell analysis is described. The system was integrated with continuous introduction of individual cells, rapid dynamic lysis, capillary electrophoretic (CE) separation and laser induced fluorescence (LIF) detection. A cross microfluidic chip with one sheath-flow channel located on each side of the sampling channel was designed. The labeled cells were hydrodynamically focused by sheath-flow streams and sequentially introduced into the cross section of the microchip under hydrostatic pressure generated by adjusting liquid levels in the reservoirs. Combined with the electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 33ms at the entry of the separation channel by Triton X-100 added in the sheath-flow solution. The maximum rate for introducing individual cells into the separation channel was about 150cells/min. The introduction of sheath-flow streams also significantly reduced the concentration of phosphate-buffered saline (PBS) injected into the separation channel along with single cells, thus reducing Joule heating during electrophoretic separation. The performance of this microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single erythrocytes. A throughput of 38cells/min was obtained. The proposed method is simple and robust for high-throughput single-cell analysis, allowing for analysis of cell population with considerable size to generate results with statistical significance. Copyright © 2010 Elsevier B.V. All rights reserved.
A novel approach for high precision rapid potentiometric titrations: application to hydrazine assay.
Sahoo, P; Malathi, N; Ananthanarayanan, R; Praveen, K; Murali, N
2011-11-01
We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ~2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO(3) in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors. © 2011 American Institute of Physics
A novel approach for high precision rapid potentiometric titrations: Application to hydrazine assay
NASA Astrophysics Data System (ADS)
Sahoo, P.; Malathi, N.; Ananthanarayanan, R.; Praveen, K.; Murali, N.
2011-11-01
We propose a high precision rapid personal computer (PC) based potentiometric titration technique using a specially designed mini-cell to carry out redox titrations for assay of chemicals in quality control laboratories attached to industrial, R&D, and nuclear establishments. Using this technique a few microlitre of sample (50-100 μl) in a total volume of ˜2 ml solution can be titrated and the waste generated after titration is extremely low comparing to that obtained from the conventional titration technique. The entire titration including online data acquisition followed by immediate offline analysis of data to get information about concentration of unknown sample is completed within a couple of minutes (about 2 min). This facility has been created using a new class of sensors, viz., pulsating sensors developed in-house. The basic concept in designing such instrument and the salient features of the titration device are presented in this paper. The performance of the titration facility was examined by conducting some of the high resolution redox titrations using dilute solutions--hydrazine against KIO3 in HCl medium, Fe(II) against Ce(IV) and uranium using Davies-Gray method. The precision of titrations using this innovative approach lies between 0.048% and 1.0% relative standard deviation in different redox titrations. With the evolution of this rapid PC based titrator it was possible to develop a simple but high precision potentiometric titration technique for quick determination of hydrazine in nuclear fuel dissolver solution in the context of reprocessing of spent nuclear fuel in fast breeder reactors.
Analysis of high aspect ratio jet flap wings of arbitrary geometry.
NASA Technical Reports Server (NTRS)
Lissaman, P. B. S.
1973-01-01
Paper presents a design technique for rapidly computing lift, induced drag, and spanwise loading of unswept jet flap wings of arbitrary thickness, chord, twist, blowing, and jet angle, including discontinuities. Linear theory is used, extending Spence's method for elliptically loaded jet flap wings. Curves for uniformly blown rectangular wings are presented for direct performance estimation. Arbitrary planforms require a simple computer program. Method of reducing wing to equivalent stretched, twisted, unblown planform for hand calculation is also given. Results correlate with limited existing data, and show lifting line theory is reasonable down to aspect ratios of 5.
Discovery of an α-Amino C–H Arylation Reaction Using the Strategy of Accelerated Serendipity
McNally, Andrew; Prier, Christopher K.; MacMillan, David W. C.
2012-01-01
Serendipity has long been a welcome yet elusive phenomenon in the advancement of chemistry. We sought to exploit serendipity as a means of rapidly identifying unanticipated chemical transformations. By using a high-throughput, automated workflow and evaluating a large number of random reactions, we have discovered a photoredox-catalyzed C–H arylation reaction for the construction of benzylic amines, an important structural motif within pharmaceutical compounds that is not readily accessed via simple substrates. The mechanism directly couples tertiary amines with cyanoaromatics by using mild and operationally trivial conditions. PMID:22116882
Transdermal Diagnosis of Malaria Using Vapor Nanobubbles.
Lukianova-Hleb, Ekaterina; Bezek, Sarah; Szigeti, Reka; Khodarev, Alexander; Kelley, Thomas; Hurrell, Andrew; Berba, Michail; Kumar, Nirbhay; D'Alessandro, Umberto; Lapotko, Dmitri
2015-07-01
A fast, precise, noninvasive, high-throughput, and simple approach for detecting malaria in humans and mosquitoes is not possible with current techniques that depend on blood sampling, reagents, facilities, tedious procedures, and trained personnel. We designed a device for rapid (20-second) noninvasive diagnosis of Plasmodium falciparum infection in a malaria patient without drawing blood or using any reagent. This method uses transdermal optical excitation and acoustic detection of vapor nanobubbles around intraparasite hemozoin. The same device also identified individual malaria parasite-infected Anopheles mosquitoes in a few seconds and can be realized as a low-cost universal tool for clinical and field diagnoses.
Li, Yi; Xu, Ming-Hua
2014-05-16
The first Rh-catalyzed asymmetric tandem cyclization of nitrogen- or oxygen-bridged 5-alkynones with arylboronic acids was achieved. The simple catalytic system involving a rhodium(I) complex with readily available chiral BINAP ligand promotes the reaction to proceed in a highly stereocontrolled manner. This protocol provides a very reliable and practical access to a variety of chiral heterocyclic tertiary allylic alcohols possessing a tetrasubstituted carbon stereocenter and an all-carbon tetrasubstituted olefin functionality in good yields with great enantioselectivities up to 99% ee.
The Initial Flow of Classical Gluon Fields in Heavy Ion Collisions
NASA Astrophysics Data System (ADS)
Fries, Rainer J.; Chen, Guangyao
2015-03-01
Using analytic solutions of the Yang-Mills equations we calculate the initial flow of energy of the classical gluon field created in collisions of large nuclei at high energies. We find radial and elliptic flow which follows gradients in the initial energy density, similar to a simple hydrodynamic behavior. In addition we find a rapidity-odd transverse flow field which implies the presence of angular momentum and should lead to directed flow in final particle spectra. We trace those energy flow terms to transverse fields from the non-abelian generalization of Gauss' Law and Ampere's and Faraday's Laws.
[Flotation and extraction spectrophotometric determination of trace silicate in water].
Di, J; Liu, Q; Li, W
2000-12-01
In HCl solution, silicate reacted with molybdate ammonium to produce silicomolibdic, then a yellow compound which was produced from the oxidation of TMB was simultaneously isolated to benzene phase by flotation and then isolated to dimethylsulfoxideformic acid by extraction. The compound gives a high absorption at 458 nm. The apparent molar absorptivity is 1.26 x 10(5) L.mol-1.cm-1. In the range of 0.02-1 mg.L-1 Si obeys Beer's law. The proposed method which combines with enrichment and measurement is simple, rapid, selective and convenient to determine silicate in water with satisfied results.
Construction of high-density bacterial colony arrays and patterns by the ink-jet method.
Xu, Tao; Petridou, Sevastioni; Lee, Eric H; Roth, Elizabeth A; Vyavahare, Narendra R; Hickman, James J; Boland, Thomas
2004-01-05
We have developed a method for fabricating bacterial colony arrays and complex patterns using commercially available ink-jet printers. Bacterial colony arrays with a density of 100 colonies/cm(2) were obtained by directly ejecting Escherichia coli (E. coli) onto agar-coated substrates at a rapid arraying speed of 880 spots per second. Adjusting the concentration of bacterial suspensions allowed single colonies of viable bacteria to be obtained. In addition, complex patterns of viable bacteria as well as bacteria density gradients were constructed using desktop printers controlled by a simple software program. Copyright 2003 Wiley Periodicals, Inc.
Zhang, Yong; Zhou, An; Xie, Xiao-Mei
2013-03-01
A simple and sensitive method has been developed to simultaneously determine betunilic acid, oleanolic acid and ursolic acid in the fruits of Ziziphus jujuba from different regions by HPLC-MS. This HPLC assay was performed on PAH polymeric C18 bonded stationary phase column with mobile phase contained acetonitrile-water (90: 10) and with negative ESI detection mode. The developed approach was characterized by short time consumption for chromatographic separation, high sensitivity and good reliability so as to meet the requirements for rapid analysis of large-batch fruits of Z. jujuba from different habitats.
A symmetric metamaterial element-based RF biosensor for rapid and label-free detection
NASA Astrophysics Data System (ADS)
Lee, Hee-Jo; Lee, Jung-Hyun; Jung, Hyo-Il
2011-10-01
A symmetric metamaterial element-based RF biosensing scheme is experimentally demonstrated by detecting biomolecular binding between a prostate-specific antigen (PSA) and its antibody. The metamaterial element in a high-impedance microstrip line shows an intrinsic S21 resonance having a Q-factor of 55. The frequency shift with PSA concentration, i.e., 100 ng/ml, 10 ng/ml, and 1 ng/ml, is observed and the changes are Δf ≈ 20 MHz, 10 MHz, and 5 MHz, respectively. The proposed biosensor offers advantages of label-free detection, a simple and direct scheme, and cost-efficient fabrication.
Wang, Feng-Lei; Zhang, Li-Ying; Zhang, Ya-Fei
2008-11-22
SiC nanowires have been synthesized at 1,600 degrees C by using a simple and low-cost method in a high-frequency induction furnace. The commercial SiO powder and the arc-discharge plasma pretreated carbon black were mixed and used as the source materials. The heating-up and reaction time is less than half an hour. It was found that most of the nanowires have core-shell SiC/SiO(2) nanostructures. The nucleation, precipitation, and growth processes were discussed in terms of the oxide-assisted cluster-solid mechanism.
Wenger, Jérôme; Gérard, Davy; Lenne, Pierre-François; Rigneault, Hervé; Dintinger, José; Ebbesen, Thomas W; Boned, Annie; Conchonaud, Fabien; Marguet, Didier
2006-12-11
Single nanometric apertures in a metallic film are used to develop a simple and robust setup for dual-color fluorescence cross-correlation spectroscopy (FCCS) at high concentrations. If the nanoaperture concept has already proven to be useful for single-species analysis, its extension to the dual-color case brings new interesting specificities. The alignment and overlap of the two excitation beams are greatly simplified. No confocal pinhole is used, relaxing the requirement for accurate correction of chromatic aberrations. Compared to two-photon excitation, nanoapertures have the advantage to work with standard fluorophore constructions having high absorption cross-section and well-known absorption/emission spectra. Thanks to the ultra-low volume analysed within one single aperture, fluorescence correlation analysis can be performed with single molecule resolution at micromolar concentrations, resulting in 3 orders of magnitude gain compared to conventional setups. As applications of this technique, we follow the kinetics of an enzymatic cleavage reaction at 2 muM DNA oligonucleotide concentration.We also demonstrate that FCCS in nanoaper-tures can be applied to the fast screening of a sample for dual-labeled species within 1 s acquisition time. This offers new possibilities for rapid screening applications in biotechnology at high concentrations.
Heinig, Uwe; Scholz, Susanne; Dahm, Pia; Grabowy, Udo; Jennewein, Stefan
2010-08-01
Classical approaches to strain improvement and metabolic engineering rely on rapid qualitative and quantitative analyses of the metabolites of interest. As an analytical tool, mass spectrometry (MS) has proven to be efficient and nearly universally applicable for timely screening of metabolites. Furthermore, gas chromatography (GC)/MS- and liquid chromatography (LC)/MS-based metabolite screens can often be adapted to high-throughput formats. We recently engineered a Saccharomyces cerevisiae strain to produce taxa-4(5),11(12)-diene, the first pathway-committing biosynthetic intermediate for the anticancer drug Taxol, through the heterologous and homologous expression of several genes related to isoprenoid biosynthesis. To date, GC/MS- and LC/MS-based high-throughput methods have been inherently difficult to adapt to the screening of isoprenoid-producing microbial strains due to the need for extensive sample preparation of these often highly lipophilic compounds. In the current work, we examined different approaches to the high-throughput analysis of taxa-4(5),11(12)-diene biosynthesizing yeast strains in a 96-deep-well format. Carbon plasma coating of standard 96-deep-well polypropylene plates allowed us to circumvent the inherent solvent instability of commonly used deep-well plates. In addition, efficient adsorption of the target isoprenoid product by the coated plates allowed rapid and simple qualitative and quantitative analyses of the individual cultures. Copyright 2010 Elsevier Inc. All rights reserved.
Sanjay, Sharma T; Dou, Maowei; Sun, Jianjun; Li, XiuJun
2016-07-26
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.
Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, XiuJun
2016-01-01
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings. PMID:27456979
NASA Astrophysics Data System (ADS)
Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, Xiujun
2016-07-01
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.
NASA Astrophysics Data System (ADS)
Berkov, D. V.; Gorn, N. L.
2018-06-01
In this paper we present a simple and effective numerical method which allows a fast Fourier transformation-based evaluation of stress generated by dislocations with arbitrary directions and Burgers vectors if the (site-dependent) dislocation density is known. Our method allows the evaluation of the dislocation stress using a rectangular grid with shape-anisotropic discretization cells without employing higher multipole moments of the dislocation interaction coefficients. Using the proposed method, we first simulate the stress created by relatively simple non-homogeneous distributions of vertical edge and so-called ‘mixed’ dislocations in a disk-shaped sample, which is necessary to understand the dislocation behavior in more complicated systems. The main part of our research is devoted to the stress distribution in polycrystalline layers with the dislocation density rapidly varying with the distance to the layer bottom. Considering GaN as a typical example of such systems, we investigate dislocation-induced stress for edge and mixed dislocations, having random orientations of Burgers vectors among crystal grains. We show that the rapid decay of the dislocation density leads to many highly non-trivial features of the stress distributions in such layers and study in detail the dependence of these features on the average grain size. Finally we develop an analytical approach which allows us to predict the evolution of the stress variance with the grain size and compare analytical predictions with numerical results.
Zhang, Liu-Xia; Cao, Yi-Ren; Xiao, Hua; Liu, Xiao-Ping; Liu, Shao-Rong; Meng, Qing-Hua; Fan, Liu-Yin; Cao, Cheng-Xi
2016-03-15
In the present work we address a simple, rapid and quantitative analytical method for detection of different proteins present in biological samples. For this, we proposed the model of titration of double protein (TDP) and its relevant leverage theory relied on the retardation signal of chip moving reaction boundary electrophoresis (MRBE). The leverage principle showed that the product of the first protein content and its absolute retardation signal is equal to that of the second protein content and its absolute one. To manifest the model, we achieved theoretical self-evidence for the demonstration of the leverage principle at first. Then relevant experiments were conducted on the TDP-MRBE chip. The results revealed that (i) there was a leverage principle of retardation signal within the TDP of two pure proteins, and (ii) a lever also existed within these two complex protein samples, evidently demonstrating the validity of TDP model and leverage theory in MRBE chip. It was also showed that the proposed technique could provide a rapid and simple quantitative analysis of two protein samples in a mixture. Finally, we successfully applied the developed technique for the quantification of soymilk in adulterated infant formula. The TDP-MRBE opens up a new window for the detection of adulteration ratio of the poor food (milk) in blended high quality one. Copyright © 2015 Elsevier B.V. All rights reserved.
Development Of A Data Assimilation Capability For RAPID
NASA Astrophysics Data System (ADS)
Emery, C. M.; David, C. H.; Turmon, M.; Hobbs, J.; Allen, G. H.; Famiglietti, J. S.
2017-12-01
The global decline of in situ observations associated with the increasing ability to monitor surface water from space motivates the creation of data assimilation algorithms that merge computer models and space-based observations to produce consistent estimates of terrestrial hydrology that fill the spatiotemporal gaps in observations. RAPID is a routing model based on the Muskingum method that is capable of estimating river streamflow over large scales with a relatively short computing time. This model only requires limited inputs: a reach-based river network, and lateral surface and subsurface flow into the rivers. The relatively simple model physics imply that RAPID simulations could be significantly improved by including a data assimilation capability. Here we present the early developments of such data assimilation approach into RAPID. Given the linear and matrix-based structure of the model, we chose to apply a direct Kalman filter, hence allowing for the preservation of high computational speed. We correct the simulated streamflows by assimilating streamflow observations and our early results demonstrate the feasibility of the approach. Additionally, the use of in situ gauges at continental scales motivates the application of our new data assimilation scheme to altimetry measurements from existing (e.g. EnviSat, Jason 2) and upcoming satellite missions (e.g. SWOT), and ultimately apply the scheme globally.
Sun, Yi; Quyen, Than Linh; Hung, Tran Quang; Chin, Wai Hoe; Wolff, Anders; Bang, Dang Duong
2015-04-21
Foodborne disease is a major public health threat worldwide. Salmonellosis, an infectious disease caused by Salmonella spp., is one of the most common foodborne diseases. Isolation and identification of Salmonella by conventional bacterial culture or molecular-based methods are time consuming and usually take a few hours to days to complete. In response to the demand for rapid on line or on site detection of pathogens, in this study, we describe for the first time an eight-chamber lab-on-a-chip (LOC) system with integrated magnetic bead-based sample preparation and loop-mediated isothermal amplification (LAMP) for rapid and quantitative detection of Salmonella spp. in food samples. The whole diagnostic procedures including DNA isolation, isothermal amplification, and real-time detection were accomplished in a single chamber. Up to eight samples could be handled simultaneously and the system was capable to detect Salmonella at concentration of 50 cells per test within 40 min. The simple design, together with high level of integration, isothermal amplification, and quantitative analysis of multiple samples in short time, will greatly enhance the practical applicability of the LOC system for rapid on-site screening of Salmonella for applications in food safety control, environmental surveillance, and clinical diagnostics.
Tian, Kun; Siegel, Gene; Tiwari, Ashutosh
2017-02-01
The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Niu, Zengyuan; Luo, Xin; Ye, Xiwen; Xiu, Xiaoli; Zhang, Li; Wang, Xin; Chen, Jing
2015-10-01
A rapid screening method based on high performance liquid chromatography-linear ion trap/orbitrap high-resolution mass spectrometry (HPLC-LTQ/Orbitrap MS) for 22 disperse dyes in ecological textiles has been established. The target compounds were extracted by pyridine/water (1:1, v/v) by shaking extraction in 90 degrees C water bath. The extracts were then separated by a CAPCELL PAK C18 column (100 mm x 2.0 mm, 5 μm) using gradient elution with acetonitrile-5 mmol/L ammonium acetate containing 0.01% (v/v) formic acid as mobile phases, and finally analyzed by HPLC-LTQ/Orbitrap in positive and negative ESI modes. The retention time and accurate mass of parent ion were used for fast screening of 22 disperse dyes, while the confirmatory analysis was obtained by fragments generated by collision-induced dissociation (CID) MS/MS. Target analysis exhibited high mass accuracy (< 5 x 10(-6)). Each target showed a good linearity in its own concentration range and the correlation coefficient was higher than 0.99. The LOQs were 0.125-2.5 mg/kg. Except for Disperse Yellow 49, the average recoveries of most disperse dyes at three spiked levels were 65%-120%, and the relative standard deviations (n = 6) were less than 15%. The method was applied for screening 40 different kinds of textiles, and Disperse Orange 37/76 was detected in one of them. With high selectivity and strong anti-jamming ability, this method is simple, rapid, accurate, and it can be used for the inspection of disperse dyes in textiles.
Turning a $10 Computer into a Powerful DIY Data Logger
NASA Astrophysics Data System (ADS)
Schilperoort, B.
2017-12-01
Due the rapid advance of consumer electronics, much more powerful and cheaper options are available for DIY projects. The $10 `Raspberry Pi Zero W' computer, with abilities like WiFi, Bluetooth, HDMI video output, and a large cheap memory, can be used for data logging purposes. The computer has a range of input and output pins on the board, with which virtually every type of digital sensor communication is possible. With an extra component, analog measurements can also be made. An extra option is the addition of a camera, which can be connected straight to the board. However, due to the relatively high power consumption (0.5 - 0.7 Watt), the `Zero W' is not optimal for off-the-grid locations. For ease of use, the collected data can be downloaded over a local WiFi network using your smartphone or a laptop. No extra software or skills are needed, it is as simple as visiting a webpage and pressing download, making data collection a quick and easy task. With simple step by step instructions you can set up your own data logger, to collect data from sensors ranging from simple temperature and water level measurements, to sonic anemometers.
Simple fluorescence-based high throughput cell viability assay for filamentous fungi.
Chadha, S; Kale, S P
2015-09-01
Filamentous fungi are important model organisms to understand the eukaryotic process and have been frequently exploited in research and industry. These fungi are also causative agents of serious diseases in plants and humans. Disease management strategies include in vitro susceptibility testing of the fungal pathogens to environmental conditions and antifungal agents. Conventional methods used for antifungal susceptibilities are cumbersome, time-consuming and are not suitable for a large-scale analysis. Here, we report a rapid, high throughput microplate-based fluorescence method for investigating the toxicity of antifungal and stress (osmotic, salt and oxidative) agents on Magnaporthe oryzae and compared it with agar dilution method. This bioassay is optimized for the resazurin reduction to fluorescent resorufin by the fungal hyphae. Resazurin bioassay showed inhibitory rates and IC50 values comparable to the agar dilution method and to previously reported IC50 or MICs for M. oryzae and other fungi. The present method can screen range of test agents from different chemical classes with different modes of action for antifungal activities in a simple, sensitive, time and cost effective manner. A simple fluorescence-based high throughput method is developed to test the effects of stress and antifungal agents on viability of filamentous fungus Magnaporthe oryzae. This resazurin fluorescence assay can detect inhibitory effects comparable to those obtained using the growth inhibition assay with added advantages of simplicity, time and cost effectiveness. This high throughput viability assay has a great potential in large-scale screening of the chemical libraries of antifungal agents, for evaluating the effects of environmental conditions and hyphal kinetic studies in mutant and natural populations of filamentous fungi. © 2015 The Society for Applied Microbiology.
Long length coated conductor fabrication by inclined substrate deposition and evaporation
NASA Astrophysics Data System (ADS)
Prusseit, W.; Hoffmann, C.; Nemetschek, R.; Sigl, G.; Handke, J.; Lümkemann, A.; Kinder, H.
2006-06-01
The commercial development of coated conductors is rapidly progressing. As a result we present an economic route to produce second generation HTS tape from the initial substrate preparation to the final metal coating. The most important and technically challenging steps are the deposition of an oriented buffer layer and the superconductor film in a reel-to-reel configuration. New evaporation techniques have been developed to enable reliable, high rate tape coating. Highly oriented MgO - buffer layers are realized by inclined substrate deposition (ISD) and DyBCO is deposited by simple e-gun evaporation yielding critical currents beyond 200 A/cm. Coated conductors have been fabricated up to 40 m length and are currently tested in a variety of applications.
Determination of acetaminophen concentrations in serum by high-pressure liquid chromatography.
Horvitz, R A; Jatlow, P I
1977-09-01
We describe a method for determination of serum acetaminophen concentrations in serum by reversed phase high-pressure liquid chromatography. The homolog N-propionyl-p-aminophenol was used as an internal standard. The procedure, which requires only a single extraction with diethyl ether, can be optimized to be linear over the ranges of 10 to 100 or 1 to 20 mg/liter. Within-run CV was 1.2%; between-run CV was 4.4% and 4.9% at two different concentrations. Many commonly used drugs were tested and found not to interfere. The procedure is simple and rapid enough for use on an emergency basis in cases of overdosage, and can be optimized for measurement of either therapeutic or toxic concentrations.
Miao, Meng; Zhao, Gaosheng; Xu, Li; Dong, Junguo; Cheng, Ping
2018-03-01
A direct analytical method based on spray-inlet microwave plasma torch tandem mass spectrometry was applied to simultaneously determine 4 phthalate esters (PAEs), namely, benzyl butyl phthalate, diethyl phthalate, dipentyl phthalate, and dodecyl phthalate with extremely high sensitivity in spirits without sample treatment. Among the 4 brands of spirit products, 3 kinds of PAE compounds were directly determined at very low concentrations from 1.30 to 114 ng·g -1 . Compared with other online and off-line methods, the spray-inlet microwave plasma torch tandem mass spectrometry technique is extremely simple, rapid, sensitive, and high efficient, providing an ideal screening tool for PAEs in spirits. Copyright © 2017 John Wiley & Sons, Ltd.
Fast 3D Surface Extraction 2 pages (including abstract)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sewell, Christopher Meyer; Patchett, John M.; Ahrens, James P.
Ocean scientists searching for isosurfaces and/or thresholds of interest in high resolution 3D datasets required a tedious and time-consuming interactive exploration experience. PISTON research and development activities are enabling ocean scientists to rapidly and interactively explore isosurfaces and thresholds in their large data sets using a simple slider with real time calculation and visualization of these features. Ocean Scientists can now visualize more features in less time, helping them gain a better understanding of the high resolution data sets they work with on a daily basis. Isosurface timings (512{sup 3} grid): VTK 7.7 s, Parallel VTK (48-core) 1.3 s, PISTONmore » OpenMP (48-core) 0.2 s, PISTON CUDA (Quadro 6000) 0.1 s.« less
Hand ultrasound: a high-fidelity simulation of lung sliding.
Shokoohi, Hamid; Boniface, Keith
2012-09-01
Simulation training has been effectively used to integrate didactic knowledge and technical skills in emergency and critical care medicine. In this article, we introduce a novel model of simulating lung ultrasound and the features of lung sliding and pneumothorax by performing a hand ultrasound. The simulation model involves scanning the palmar aspect of the hand to create normal lung sliding in varying modes of scanning and to mimic ultrasound features of pneumothorax, including "stratosphere/barcode sign" and "lung point." The simple, reproducible, and readily available simulation model we describe demonstrates a high-fidelity simulation surrogate that can be used to rapidly illustrate the signs of normal and abnormal lung sliding at the bedside. © 2012 by the Society for Academic Emergency Medicine.
A Simple and Efficient Method for Assembling TALE Protein Based on Plasmid Library
Xu, Huarong; Xin, Ying; Zhang, Tingting; Ma, Lixia; Wang, Xin; Chen, Zhilong; Zhang, Zhiying
2013-01-01
DNA binding domain of the transcription activator-like effectors (TALEs) from Xanthomonas sp. consists of tandem repeats that can be rearranged according to a simple cipher to target new DNA sequences with high DNA-binding specificity. This technology has been successfully applied in varieties of species for genome engineering. However, assembling long TALE tandem repeats remains a big challenge precluding wide use of this technology. Although several new methodologies for efficiently assembling TALE repeats have been recently reported, all of them require either sophisticated facilities or skilled technicians to carry them out. Here, we described a simple and efficient method for generating customized TALE nucleases (TALENs) and TALE transcription factors (TALE-TFs) based on TALE repeat tetramer library. A tetramer library consisting of 256 tetramers covers all possible combinations of 4 base pairs. A set of unique primers was designed for amplification of these tetramers. PCR products were assembled by one step of digestion/ligation reaction. 12 TALE constructs including 4 TALEN pairs targeted to mouse Gt(ROSA)26Sor gene and mouse Mstn gene sequences as well as 4 TALE-TF constructs targeted to mouse Oct4, c-Myc, Klf4 and Sox2 gene promoter sequences were generated by using our method. The construction routines took 3 days and parallel constructions were available. The rate of positive clones during colony PCR verification was 64% on average. Sequencing results suggested that all TALE constructs were performed with high successful rate. This is a rapid and cost-efficient method using the most common enzymes and facilities with a high success rate. PMID:23840477
A simple and efficient method for assembling TALE protein based on plasmid library.
Zhang, Zhiqiang; Li, Duo; Xu, Huarong; Xin, Ying; Zhang, Tingting; Ma, Lixia; Wang, Xin; Chen, Zhilong; Zhang, Zhiying
2013-01-01
DNA binding domain of the transcription activator-like effectors (TALEs) from Xanthomonas sp. consists of tandem repeats that can be rearranged according to a simple cipher to target new DNA sequences with high DNA-binding specificity. This technology has been successfully applied in varieties of species for genome engineering. However, assembling long TALE tandem repeats remains a big challenge precluding wide use of this technology. Although several new methodologies for efficiently assembling TALE repeats have been recently reported, all of them require either sophisticated facilities or skilled technicians to carry them out. Here, we described a simple and efficient method for generating customized TALE nucleases (TALENs) and TALE transcription factors (TALE-TFs) based on TALE repeat tetramer library. A tetramer library consisting of 256 tetramers covers all possible combinations of 4 base pairs. A set of unique primers was designed for amplification of these tetramers. PCR products were assembled by one step of digestion/ligation reaction. 12 TALE constructs including 4 TALEN pairs targeted to mouse Gt(ROSA)26Sor gene and mouse Mstn gene sequences as well as 4 TALE-TF constructs targeted to mouse Oct4, c-Myc, Klf4 and Sox2 gene promoter sequences were generated by using our method. The construction routines took 3 days and parallel constructions were available. The rate of positive clones during colony PCR verification was 64% on average. Sequencing results suggested that all TALE constructs were performed with high successful rate. This is a rapid and cost-efficient method using the most common enzymes and facilities with a high success rate.
Yamamoto, Ikuo; Ota, Ren; Zhu, Rui; Lawn, Murray; Ishimatsu, Takakazu; Nagayasu, Takeshi; Yamasaki, Naoya; Takagi, Katsunori; Koji, Takehiko
2015-01-01
In the area of manufacturing surgical instruments, the ability to rapidly design, prototype and test surgical instruments is critical. This paper provides a simple case study of the rapid development of two bio-mechanism based surgical instruments which are ergonomic, aesthetic and were successfully designed, prototyped and conceptually tested in a very short period of time.
Rapid flow cytometric measurement of protein inclusions and nuclear trafficking
Whiten, D. R.; San Gil, R.; McAlary, L.; Yerbury, J. J.; Ecroyd, H.; Wilson, M. R.
2016-01-01
Proteinaceous cytoplasmic inclusions are an indicator of dysfunction in normal cellular proteostasis and a hallmark of many neurodegenerative diseases. We describe a simple and rapid new flow cytometry-based method to enumerate, characterise and, if desired, physically recover protein inclusions from cells. This technique can analyse and resolve a broad variety of inclusions differing in both size and protein composition, making it applicable to essentially any model of intracellular protein aggregation. The method also allows rapid quantification of the nuclear trafficking of fluorescently labelled molecules. PMID:27516358
Directions for computational mechanics in automotive crashworthiness
NASA Technical Reports Server (NTRS)
Bennett, James A.; Khalil, T. B.
1993-01-01
The automotive industry has used computational methods for crashworthiness since the early 1970's. These methods have ranged from simple lumped parameter models to full finite element models. The emergence of the full finite element models in the mid 1980's has significantly altered the research direction. However, there remains a need for both simple, rapid modeling methods and complex detailed methods. Some directions for continuing research are discussed.
Simple system for locating ground loops.
Bellan, P M
2007-06-01
A simple low-cost system for rapid identification of the cables causing ground loops in complex instrumentation configurations is described. The system consists of an exciter module that generates a 100 kHz ground loop current and a detector module that determines which cable conducts this test current. Both the exciter and detector are magnetically coupled to the ground circuit so there is no physical contact to the instrumentation system under test.
Directions for computational mechanics in automotive crashworthiness
NASA Astrophysics Data System (ADS)
Bennett, James A.; Khalil, T. B.
1993-08-01
The automotive industry has used computational methods for crashworthiness since the early 1970's. These methods have ranged from simple lumped parameter models to full finite element models. The emergence of the full finite element models in the mid 1980's has significantly altered the research direction. However, there remains a need for both simple, rapid modeling methods and complex detailed methods. Some directions for continuing research are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weeks, J.M.; Svendsen, C.
A simple subcellular histochemical staining technique employing the lysosomal probe neutral red has been developed for use with the epiendogeic earthworm Lumbricus rubellus Hoffmeister. Coelomocytes extracted from the coelomic cavity of earthworms into an isotonic earthworm Ringer solution were allowed to adhere to a microscope slide for 30 s before the application of a neutral red dye. This red dye was rapidly accumulated within the lysosomes. Observation of the loss of this dye from these lysosomes into the surrounding cytosol has enabled the quantification of the degree of lysosomal damage caused to earthworms with exposure to an increasing range ofmore » soil copper concentrations, in both laboratory and mesocosm studies. This simple in vitro biomarker has potential for the rapid assessment of the toxic effects to earthworms from soils contaminated with heavy metals and metalloids.« less
2012-01-01
A computer numerical control (CNC) apparatus was used to perform droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling on a single superhydrophobic surface and a multi-chambered PCB heater. Droplets were manipulated using “wire-guided” method (a pipette tip was used in this study). This methodology can be easily adapted to existing commercial robotic pipetting system, while demonstrated added capabilities such as vibrational mixing, high-speed centrifuging of droplets, simple DNA extraction utilizing the hydrophobicity difference between the tip and the superhydrophobic surface, and rapid thermocycling with a moving droplet, all with wire-guided droplet manipulations on a superhydrophobic surface and a multi-chambered PCB heater (i.e., not on a 96-well plate). Serial dilutions were demonstrated for diluting sample matrix. Centrifuging was demonstrated by rotating a 10 μL droplet at 2300 round per minute, concentrating E. coli by more than 3-fold within 3 min. DNA extraction was demonstrated from E. coli sample utilizing the disposable pipette tip to cleverly attract the extracted DNA from the droplet residing on a superhydrophobic surface, which took less than 10 min. Following extraction, the 1500 bp sequence of Peptidase D from E. coli was amplified using rapid droplet thermocycling, which took 10 min for 30 cycles. The total assay time was 23 min, including droplet centrifugation, droplet DNA extraction and rapid droplet thermocycling. Evaporation from of 10 μL droplets was not significant during these procedures, since the longest time exposure to air and the vibrations was less than 5 min (during DNA extraction). The results of these sequentially executed processes were analyzed using gel electrophoresis. Thus, this work demonstrates the adaptability of the system to replace many common laboratory tasks on a single platform (through re-programmability), in rapid succession (using droplets), and with a high level of accuracy and automation. PMID:22947281
Chan, Kamfai; Wong, Pui-Yan; Parikh, Chaitanya; Wong, Season
2018-03-15
Traditionally, the majority of nucleic acid amplification-based molecular diagnostic tests are done in centralized settings. In recent years, point-of-care tests have been developed for use in low-resource settings away from central laboratories. While most experts agree that point-of-care molecular tests are greatly needed, their availability as cost-effective and easy-to-operate tests remains an unmet goal. In this article, we discuss our efforts to develop a recombinase polymerase amplification reaction-based test that will meet these criteria. First, we describe our efforts in repurposing a low-cost 3D printer as a platform that can carry out medium-throughput, rapid, and high-performing nucleic acid extraction. Next, we address how these purified templates can be rapidly amplified and analyzed using the 3D printer's heated bed or the deconstructed, low-cost thermal cycler we have developed. In both approaches, real-time isothermal amplification and detection of template DNA or RNA can be accomplished using a low-cost portable detector or smartphone camera. Last, we demonstrate the capability of our technologies using foodborne pathogens and the Zika virus. Our low-cost approach does not employ complicated and high-cost components, making it suitable for resource-limited settings. When integrated and commercialized, it will offer simple sample-to-answer molecular diagnostics. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Yuanyuan; Peng, Yankun; Zhang, Leilei; Dhakal, Sagar; Wang, Caiping
2014-05-01
Pork is one of the highly consumed meat item in the world. With growing improvement of living standard, concerned stakeholders including consumers and regulatory body pay more attention to comprehensive quality of fresh pork. Different analytical-laboratory based technologies exist to determine quality attributes of pork. However, none of the technologies are able to meet industrial desire of rapid and non-destructive technological development. Current study used optical instrument as a rapid and non-destructive tool to classify 24 h-aged pork longissimus dorsi samples into three kinds of meat (PSE, Normal and DFD), on the basis of color L* and pH24. Total of 66 samples were used in the experiment. Optical system based on Vis/NIR spectral acquisition system (300-1100 nm) was self- developed in laboratory to acquire spectral signal of pork samples. Median smoothing filter (M-filter) and multiplication scatter correction (MSC) was used to remove spectral noise and signal drift. Support vector machine (SVM) prediction model was developed to classify the samples based on their comprehensive qualities. The results showed that the classification model is highly correlated with the actual quality parameters with classification accuracy more than 85%. The system developed in this study being simple and easy to use, results being promising, the system can be used in meat processing industry for real time, non-destructive and rapid detection of pork qualities in future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandari, Deepak; Van Berkel, Gary J
2012-01-01
The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45more » min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.« less
Yang, Yang; Qin, Xiaodong; Zhang, Xiangle; Zhao, Zhixun; Zhang, Wei; Zhu, Xueliang; Cong, Guozheng; Li, Yanmin; Zhang, Zhidong
2017-07-17
Goatpox virus (GTPV) and sheeppox virus (SPPV), which belong to the Capripoxvirus (CaPV), are economically important pathogens of small ruminants. Therefore, a sensitive, specific and rapid diagnostic assay for detection of GTPV and SPPV is necessary to accurately and promptly control these diseases. Recombinase polymerase amplification (RPA) assays combined with a real-time fluorescent detection (real-time RPA assay) and lateral flow dipstick (RPA LFD assay) were developed targeting the CaPV G-protein-coupled chemokine receptor (GPCR) gene, respectively. The sensitivity of both CaPV real-time RPA assay and CaPV RPA LFD assay were 3 × 10 2 copies per reaction within 20 min at 38 °C. Both assays were highly specific for CaPV, with no cross-reactions with peste des petits ruminants virus, foot-and-mouth disease virus and Orf virus. The evaluation of the performance of these two assays with clinical sample (n = 107) showed that the CaPV real-time RPA assay and CaPV RPA LFD assay were able to specially detect SPPV or GTPV present in samples of ovine in liver, lung, kidney, spleen, skin and blood. This study provided a highly time-efficient and simple alternative for rapid detection of GTPV and SPPV.
Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam
2017-01-01
Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748