Sample records for simple screening test

  1. Health Information in Bengali (Bangla / বাংলা)

    MedlinePlus

    ... Society Guidelines for the Early Detection of Cancer - English PDF American Cancer Society Guidelines for the Early ... Screening It's a Simple Test - Cervical Cancer Screening - English PDF It's a Simple Test - Cervical Cancer Screening - ...

  2. Simple Screening Test for Exercise-Induced Bronchospasm in the Middle School Athlete

    ERIC Educational Resources Information Center

    Weiss, Tyler J.; Baker, Rachel H.; Weiss, Jason B.; Weiss, Michelle M.

    2013-01-01

    This article recommends and provides results from a simple screening test that could be incorporated into a standardized school evaluation for all children participating in sports and physical education classes. The test can be employed by physical educators utilizing their own gym to identify children who demonstrate signs of exercise-induced…

  3.  The product of triglycerides and glucose as biomarker for screening simple steatosis and NASH in asymptomatic women.

    PubMed

    Simental-Mendía, Luis E; Simental-Mendía, Esteban; Rodríguez-Hernández, Heriberto; Rodríguez-Morán, Martha; Guerrero-Romero, Fernando

    2016-01-01

     Introduction and aim. Given that early identification of non-alcoholic fatty liver disease (NAFLD) is an important issue for primary prevention of hepatic disease, the objectives of this study were to evaluate the efficacy of the product of triglyceride and glucose levels (TyG) for screening simple steatosis and non-alcoholic steatohepatitis (NASH) in asymptomatic women, and to compare its efficacy vs. other biomarkers for recognizing NAFLD. Asymptomatic women aged 20 to 65 years were enrolled into a cross-sectional study. The optimal values of TyG, for screening simple steatosis and NASH were established on a Receiver Operating Characteristic scatter plot; the sensitivity, specificity, and likelihood ratios of TyG index were estimated versus liver biopsy. According sensitivity and specificity, the efficacy of TyG was compared versus the well-known clinical biomarkers for recognizing NAFLD. A total of 50 asymptomatic women were enrolled. The best cutoff point of TyG for screening simple steatosis was 4.58 (sensitivity 0.94, specificity 0.69); in addition, the best cutoff point of TyG index for screening NASH was 4.59 (sensitivity 0.87, specificity 0.69). The positive and negative likelihood ratios were 3.03 and 0.08 for simple steatosis, and 2.80 and 0.18 for NASH. As compared versus SteatoTest, NashTest, Fatty liver index, and Algorithm, the TyG showed to be the best test for screening. TyG has high sensitivity and low negative likelihood ratio; as compared with other clinical biomarkers, the TyG showed to be the best test for screening simple steatosis and NASH.

  4. NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid

    NASA Technical Reports Server (NTRS)

    Wollen, Mark; Bakke, Victor; Baker, James

    2012-01-01

    While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.

  5. Additional mailing phase for FIT after a medical offer phase: The best way to improve compliance with colorectal cancer screening in France.

    PubMed

    Piette, Christine; Durand, Gérard; Bretagne, Jean-François; Faivre, Jean

    2017-03-01

    Compliance with colorectal cancer screening is critical to its effectiveness. The organisation of the mass screening programme in France has recently been modified with no evaluation of the consequences. To evaluate the impact of the way the screening test is delivered on compliance. During the first six months of the screening campaign (Ille-Vilaine, Brittany), general practitioners were asked to propose a faecal immunochemical test (FIT), OC-Sensor, to individuals at average risk for colorectal cancer (n=152,097). A subset of non-participants in the medical phase (n=13,071) was randomly chosen to receive a reminder that included the screening test or a simple postal reminder without the screening test. Compliance was 31% if the screening test was proposed during a medical consultation. In non-participants during the medical phase, it was 45% in those receiving both a reminder and the screening test and 28% amongst those receiving a simple reminder. An estimated overall participation rate of 54% can be expected if non-participants in the medical phase are sent a reminder together with the screening test. In France, a compliance rate above the minimum uptake rate of 45% recommended by European Union experts can be achieved if the FIT is mailed to non-participants after the medical free-offer phase. Copyright © 2016. Published by Elsevier Ltd.

  6. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  7. Being screened for prostate cancer: a simple blood test or a commitment to treatment?

    PubMed

    Oliffe, John

    2006-01-01

    The virtues of screening men for prostate cancer continue to be debated in political and public health, as well as clinical forums. Science has been unable to accurately predict screening benefits, yet many men are required to make informed decisions about prostate cancer screening. Clinicians' screening practices have been reported, but little research attention has been given to patients' experiences. The purpose of this study was to describe patients' perspectives of being screened and subsequently diagnosed with prostate cancer. Thirty-five Anglo-Australian men were interviewed, and the data were analyzed using ethnographic content analysis. The findings indicated that most participants experienced screening as a continuum of 3 tests, rather than the simple prostate-specific antigen blood test they had often anticipated. Commitment to a definitive diagnosis when abnormality was detected through screening and uptake of active treatment(s) when prostate cancer was confirmed were strongly represented in this study. The findings offer insight to the complex and often rapid sequence of events that can accompany prostate cancer screening. This has implications for the information that needs to be discussed with men before, rather than after prostate cancer screening has commenced.

  8. A Simple Method for High Throughput Chemical Screening in Caenorhabditis Elegans

    PubMed Central

    Lucanic, Mark; Garrett, Theo; Gill, Matthew S.; Lithgow, Gordon J.

    2018-01-01

    Caenorhabditis elegans is a useful organism for testing chemical effects on physiology. Whole organism small molecule screens offer significant advantages for identifying biologically active chemical structures that can modify complex phenotypes such as lifespan. Described here is a simple protocol for producing hundreds of 96-well culture plates with fairly consistent numbers of C. elegans in each well. Next, we specified how to use these cultures to screen thousands of chemicals for effects on the lifespan of the nematode C. elegans. This protocol makes use of temperature sensitive sterile strains, agar plate conditions, and simple animal handling to facilitate the rapid and high throughput production of synchronized animal cultures for screening. PMID:29630057

  9. A simple and rapid radiochemical choline acetyltransferase (ChAT) assay screening test.

    PubMed

    Shiba, Kazuhiro; Ogawa, Kazuma; Kinuya, Seigo; Yajima, Kazuyoshi; Mori, Hirofumi

    2006-10-15

    A simple radiochemical choline acetyltransferase (ChAT) assay screening test was developed by measuring for [(3)H]acetylcholine ([(3)H]ACh) formed from 0.2 mM [(3)H]acetyl-coenzyme A ([(3)H]acetyl-CoA) and 1 mM choline by 0.2 mg of rat brain homogenates containing ChAT into 96-well microplates. A simple and rapid procedure for isolating [(3)H]ACh from the incubation mixture into 96-well microplates was achieved by using a sodium tetraphenylboron (Kalibor) solution (in ethyl acetate, 0.75%, w/v) and a hydrophobic liquid scintillator mixture (1:5, v/v, 0.2 mL) as an extraction solvent. The benefits of this radiochemical method using 96-well microplates are as follows: (1) this method is reliable and reproducible; (2) many samples can be examined at the same time by this method; (3) this method is economical and effective in reducing radioactive waste. The development of a new simple radiochemical ChAT assay screening test is the first stage of development of radiolabeled ChAT mapping agent.

  10. Development and verification of a model for estimating the screening utility in the detection of PCBs in transformer oil.

    PubMed

    Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya

    2014-01-01

    A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.

  11. Touch Interaction with 3D Geographical Visualization on Web: Selected Technological and User Issues

    NASA Astrophysics Data System (ADS)

    Herman, L.; Stachoň, Z.; Stuchlík, R.; Hladík, J.; Kubíček, P.

    2016-10-01

    The use of both 3D visualization and devices with touch displays is increasing. In this paper, we focused on the Web technologies for 3D visualization of spatial data and its interaction via touch screen gestures. At the first stage, we compared the support of touch interaction in selected JavaScript libraries on different hardware (desktop PCs with touch screens, tablets, and smartphones) and software platforms. Afterward, we realized simple empiric test (within-subject design, 6 participants, 2 simple tasks, LCD touch monitor Acer and digital terrain models as stimuli) focusing on the ability of users to solve simple spatial tasks via touch screens. An in-house testing web tool was developed and used based on JavaScript, PHP, and X3DOM languages and Hammer.js libraries. The correctness of answers, speed of users' performances, used gestures, and a simple gesture metric was recorded and analysed. Preliminary results revealed that the pan gesture is most frequently used by test participants and it is also supported by the majority of 3D libraries. Possible gesture metrics and future developments including the interpersonal differences are discussed in the conclusion.

  12. A Low-Cost and Simple Genetic Screening for Cystic Fibrosis Provided by the Brazilian Public Health System.

    PubMed

    Rispoli, Thaiane; Martins de Castro, Simone; Grandi, Tarciana; Prado, Mayara; Filippon, Letícia; Dornelles da Silva, Cláudia Maria; Vargas, José Eduardo; Rossetti, Lucia Maria Rosa

    2018-05-03

    Cystic fibrosis newborn screening was implemented in Brazil by the Public Health System in 2012. Because of cost, only 1 mutation was tested - p.Phe508del. We developed a robust low-cost genetic test for screening 11 CFTR gene mutations with potential use in developing countries. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. SCIENTIFIC AND TECHNOLOGICAL SUPPORT ON IN VITRO ASSAYS FOR THE AGENCY'S ENDOCRINE DISRUPTOR SCREENING PROGRAM

    EPA Science Inventory

    In response to the 1996 legislative mandate for an endocrine screening and testing program, we are helping develop, standardize and validate relatively sensitive, robust and relatively simple methods for in vitro screening of chemicals that affect estrogen, and androgen function ...

  14. Vision Screening

    MedlinePlus

    ... testing when performed at a doctor's office. Corneal light reflex testing This simple test can be performed ... focuses on a penlight, the position of the light reflection from the front surface (cornea) of the ...

  15. Experience using the «Shetty test» for initial foot and ankle fracture screening in the Emergency Department.

    PubMed

    Ojeda-Jiménez, J; Méndez-Ojeda, M M; Martín-Vélez, P; Tejero-García, S; Pais-Brito, J L; Herrera-Pérez, M

    2018-03-20

    The indiscriminate practice of radiographs for foot and ankle injuries is not justified and numerous studies have corroborated the usefulness of clinical screening tests such as the Ottawa Ankle Rules. The aim of our study is to clinically validate the so-called Shetty Test in our area. A cross-sectional observational study by applying the Shetty test to patients seen in the Emergency Department. We enrolled 100 patients with an average age of 39.25 (16-86). The Shetty test was positive on 14 occasions. Subsequent radiography revealed a fracture in 10 cases: 4 were false positives. The test was negative in the remaining 86 patients and radiography confirmed the absence of fracture (with sensitivity of 100% and specificity of 95.56%, positive predictive value of 71.40%, and negative predictive value of 100%). The Shetty test is a valid clinical screening tool to decide whether simple radiography is indicated for foot and ankle injuries. It is a simple, quick and reproducible test. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. A Screening Test for Wilson's Disease and its Application to Psychiatric Patients

    PubMed Central

    Cox, Diane Wilson

    1967-01-01

    Varied modes of onset make the early diagnosis of Wilson's disease difficult. A deficiency of serum ceruloplasmin, usually characteristic of the disease, was used as the basis for a screening test. Simple test materials and provision for handling about 50 plasma samples simultaneously made this test feasible for large-scale screening. The screening test was applied to 336 persons hospitalized for psychiatric disorders, to detect patients with Wilson's disease before the classical symptoms appeared. Two patients with ceruloplasmin levels below the normal limits were detected but did not have Wilson's disease. Further application of the screening test to relatives of patients known to have Wilson's disease and to individuals with any symptoms of the disease (hepatic disease, extrapyramidal dysfunction, psychiatric disorders, behaviour problems in children) would aid in early diagnosis and more effective treatment. ImagesFig. 1 PMID:6017170

  17. Simple and fast screening of G-quadruplex ligands with electrochemical detection system.

    PubMed

    Fan, Qiongxuan; Li, Chao; Tao, Yaqin; Mao, Xiaoxia; Li, Genxi

    2016-11-01

    Small molecules that may facilitate and stabilize the formation of G-quadruplexes can be used for cancer treatments, because the G-quadruplex structure can inhibit the activity of telomerase, an enzyme over-expressed in many cancer cells. Therefore, there is considerable interest in developing a simple and high-performance method for screening small molecules binding to G-quadruplex. Here, we have designed a simple electrochemical approach to screen such ligands based on the fact that the formation and stabilization of G-quadruplex by ligand may inhibit electron transfer of redox species to electrode surface. As a proof-of-concept study, two types of classical G-quadruplex ligands, TMPyP4 and BRACO-19, are studied in this work, which demonstrates that this method is fast and robust and it may be applied to screen G-quadruplex ligands for anticancer drugs testing and design in the future. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Coins and Costs: A Simple and Rapid Assessment of Basic Financial Knowledge

    ERIC Educational Resources Information Center

    Willner, Paul; Bailey, Rebecca; Dymond, Simon; Parry, Rhonwen

    2011-01-01

    Introduction: We describe a simple and rapid screening test for basic financial knowledge that is suitable for administration to people with mild intellectual disabilities. Method: The Coins and Costs test asks respondents to name coins, and to estimate prices of objects ranging between 1 British Pound (an ice cream) and 100K British Pounds (a…

  19. Results of anti-mortem screening methodology to predict prescribed drug withholding periods for flunixin and ceftiofur in heifers

    USDA-ARS?s Scientific Manuscript database

    Introduction: A simple, cow-side test for the presence of drug residues in live animals would be useful for drug residue avoidance programs. Simple inhibition tests used at slaughter do not detect some drug tolerance concentrations such as those for flunixin and ceftiofur-metabolites. This experim...

  20. [Simple method for precognition of drug interaction between oral iron and phenolic hydroxyl group-containing drugs].

    PubMed

    Sunagane, Nobuyoshi; Yoshinobu, Etsuko; Murayama, Nobuko; Terawaki, Yasufumi; Kamimura, Naoki; Uruno, Tsutomu

    2005-02-01

    In the present study, we devised a simple method for detecting the drug interaction between oral iron preparations and phenolic hydroxyl group-containing drugs, using the coloring reaction as indicator, due to the formation of complexes or chelates. In the method, oral iron preparations and test drugs in amounts as much as single dose for adults were added to 10 ml of purified water to make sample suspensions for testing. Thirty minutes after mixing an oral iron suspension and a test drug suspension, the change of color in the mixture was observed macroscopically and graded as 0 to 3, with a marked color change judged as grade 3 and no color change as grade 0. Screening of 14 test drugs commonly used orally was carried out. When using sodium ferrous citrate preparations as oral iron, 5 were classified as grade 3, 2 as grade 2, 4 as grade 1, and 3 as grade 0, respectively. To verify usefulness of the method, the interactions suggested by screening were pharmacokinetically assessed by measuring serum concentrations of the drug in mice. When a levodopa or droxidopa preparation, judged as grade 3 in screening, was concomitantly administered with an iron preparation, a significant reduction in bioavailability of the test drug was observed, indicating possible drug interaction between the test drug and oral iron. Combined administration of an acetaminophen preparation, judged as grade 1, and oral iron preparation showed no influence on the bioavailability of the test drug, implying no detectable interactions between them. In conclusion, the simple method devised in the present study is useful for precognition of drug interactions between oral iron preparations and phenolic hydroxyl group-containing drugs, and the drugs with a higher grade in screening may induce drug interactions with oral iron.

  1. Promoting protein crystallization using a plate with simple geometry.

    PubMed

    Chen, Rui-Qing; Yin, Da-Chuan; Liu, Yong-Ming; Lu, Qin-Qin; He, Jin; Liu, Yue

    2014-03-01

    Increasing the probability of obtaining protein crystals in crystallization screening is always an important goal for protein crystallography. In this paper, a new method called the cross-diffusion microbatch (CDM) method is presented, which aims to efficiently promote protein crystallization and increase the chance of obtaining protein crystals. In this method, a very simple crystallization plate was designed in which all crystallization droplets are in one sealed space, so that a variety of volatile components from one droplet can diffuse into any other droplet via vapour diffusion. Crystallization screening and reproducibility tests indicate that this method could be a potentially powerful technique in practical protein crystallization screening. It can help to obtain crystals with higher probability and at a lower cost, while using a simple and easy procedure.

  2. Cholesterol and Your Child

    MedlinePlus

    ... can order a simple blood test , usually done fasting (nothing to eat or drink, except water, for ... screening healthy kids without risk factors, a non-fasting blood test can be used. According to the ...

  3. Screening Technique for Lead and Cadmium in Toys and Other Materials Using Atomic Absorption Spectroscopy

    ERIC Educational Resources Information Center

    Brouwer, Henry

    2005-01-01

    A simple procedure to quickly screen different consumer products for the presence of lead, cadmium, and other metals is described. This screening technique avoids expending a lot of preparation time on samples known to contain low levels of hazardous metals where only samples testing positive for the desired elements need to be analyzed…

  4. Colorectal cancer screening: An updated review of the available options.

    PubMed

    Issa, Iyad A; Noureddine, Malak

    2017-07-28

    Colorectal cancer (CRC) is a significant cause of morbidity and mortality worldwide. However, colon cancer incidence and mortality is declining over the past decade owing to adoption of effective screening programs. Nevertheless, in some parts of the world, CRC incidence and mortality remain on the rise, likely due to factors including "westernized" diet, lifestyle, and lack of health-care infrastructure and resources. Participation and adherence to different national screening programs remain obstacles limiting the achievement of screening goals. Different modalities are available ranging from stool based tests to radiology and endoscopy with varying sensitivity and specificity. However, the availability of these tests is limited to areas with high economic resources. Recently, FDA approved a blood-based test (Epi procolon ® ) for CRC screening. This blood based test may serve to increase the participation and adherence rates. Hence, leading to increase in colon cancer detection and prevention. This article will discuss various CRC screening tests with a particular focus on the data regarding the new approved blood test. Finally, we will propose an algorithm for a simple cost-effective CRC screening program.

  5. Colorectal cancer screening: An updated review of the available options

    PubMed Central

    Issa, Iyad A; Noureddine, Malak

    2017-01-01

    Colorectal cancer (CRC) is a significant cause of morbidity and mortality worldwide. However, colon cancer incidence and mortality is declining over the past decade owing to adoption of effective screening programs. Nevertheless, in some parts of the world, CRC incidence and mortality remain on the rise, likely due to factors including “westernized” diet, lifestyle, and lack of health-care infrastructure and resources. Participation and adherence to different national screening programs remain obstacles limiting the achievement of screening goals. Different modalities are available ranging from stool based tests to radiology and endoscopy with varying sensitivity and specificity. However, the availability of these tests is limited to areas with high economic resources. Recently, FDA approved a blood-based test (Epi procolon®) for CRC screening. This blood based test may serve to increase the participation and adherence rates. Hence, leading to increase in colon cancer detection and prevention. This article will discuss various CRC screening tests with a particular focus on the data regarding the new approved blood test. Finally, we will propose an algorithm for a simple cost-effective CRC screening program. PMID:28811705

  6. Annual Research Progress Report, Fiscal Year 1980,

    DTIC Science & Technology

    1980-10-01

    Uric Acid Levels at 36 Weeks Gestation as 45 Screening Test for Preeclampsia as an Aid to Further Manage- ment. (0) DEPARTMENT OF PSYCHIATRY...Investigators: CPT Ellis M. Knight, MC Key Words: Serum Uric Acid Preeclampsia Accumulative MEDCASE Est Accumulative Periodic Ap-roved for continuation...Cost: 0 OMA Cost: 0 Review Results Study Objective: To demonstrate that: A. Serum uric acid level is a simple specific screening test for preeclampsia

  7. Qualified Fitness and Exercise as Professionals and Exercise Prescription: Evolution of the PAR-Q and Canadian Aerobic Fitness Test.

    PubMed

    Shephard, Roy J

    2015-04-01

    Traditional approaches to exercise prescription have included a preliminary medical screening followed by exercise tests of varying sophistication. To maximize population involvement, qualified fitness and exercise professionals (QFEPs) have used a self-administered screening questionnaire (the Physical Activity Readiness Questionnaire, PAR-Q) and a simple measure of aerobic performance (the Canadian Aerobic Fitness Test, CAFT). However, problems have arisen in applying the original protocol to those with chronic disease. Recent developments have addressed these issues. Evolution of the PAR-Q and CAFT protocol is reviewed from their origins in 1974 to the current electronic decision tree model of exercise screening and prescription. About a fifth of apparently healthy adults responded positively to the original PAR-Q instrument, thus requiring an often unwarranted referral to a physician. Minor changes of wording did not overcome this problem. However, a consensus process has now developed an electronic decision tree for stratification of exercise risk not only for healthy individuals, but also for those with various types of chronic disease. The new approach to clearance greatly reduces physician referrals and extends the role of QFEPs. The availability of effective screening and simple fitness testing should contribute to the goal of maximizing physical activity in the entire population.

  8. Physiological Capacities: Estimating an Athlete's Potential.

    ERIC Educational Resources Information Center

    Lemon, Peter W. R.

    1982-01-01

    Several simple performance tests are described for assessing an athlete's major energy-producing capabilities. The tests are suitable for mass screening because they are easy to administer, require no sophisticated equipment, and can be done quickly. Information for evaluating test results is included. (PP)

  9. Newborn hearing screening update for midwifery practice.

    PubMed

    Narrigan, D

    2000-01-01

    Neonatal identification of congenital hearing impairment allows interventions during the first 3 years, the critical period for language and speech development. Two recently developed biophysical testing methods offer simple, accurate, and relatively inexpensive means to identify the one to three in 1,000 healthy newborns with hearing loss. Universal screening for auditory system integrity is advocated, because almost half of all newborns with hearing impairment have no risk factors associated with this impairment. Critics of universal screening cite the high rate of false positive tests (up to 7%), which increases program costs from follow-up and re-testing large numbers of infants to ensure identifying the few affected infants. As of early 2000, 24 states had introduced some type of auditory screening program, and the U.S. Congress had passed legislation with appropriations mandating state-based auditory screening for all newborns. Midwives practicing in states already mandating biophysical screening need to comply with their local requirements; those in other states may voluntarily incorporate new auditory test methods into practice.

  10. Low levels of neurocognitive impairment detected in screening HIV-infected men who have sex with men: The MSM Neurocog Study.

    PubMed

    Barber, T J; Bansi, L; Pozniak, A; Asboe, D; Nelson, M; Moyle, G; Davies, N; Margetts, A; Ratcliffe, D; Catalan, J; Boffito, M; Gazzard, B

    2017-06-01

    This study aimed to determine the prevalence of HIV neurocognitive impairment in HIV-infected men who have sex with men aged 18-50 years, using a simple battery of screening tests in routine clinical appointments. Those with suspected abnormalities were referred on for further assessment. The cohort was also followed up over time to look at evolving changes. HIV-infected participants were recruited at three clinical sites in London during from routine clinical visits. They could be clinician or self-referred and did not need to be symptomatic. They completed questionnaires on anxiety, depression, and memory. They were then screened using the Brief Neurocognitive Screen (BNCS) and International HIV Dementia Scale (IHDS). Two hundred and five HIV-infected subjects were recruited. Of these, 59 patients were excluded as having a mood disorder and two patients were excluded due to insufficient data, leaving 144 patients for analysis. One hundred and twenty-four (86.1%) had a normal composite z score (within 1 SD of mean) calculated for their scores on the three component tests of the BNCS. Twenty (13.9%) had an abnormal z score, of which seven (35%) were symptomatic and 13 (65%) asymptomatic. Current employment and previous educational level were significantly associated with BNCS scores. Of those referred onwards for diagnostic testing, only one participant was found to have impairment likely related to HIV infection. We were able to easily screen for mood disorders and cognitive impairment in routine clinical practice. We identified a high level of depression and anxiety in our cohort. Using simple screening tests in clinic and an onward referral process for further testing, we were not able to identify neurocognitive impairment in this cohort at levels consistent with published data.

  11. Rodent models of depression: forced swim and tail suspension behavioral despair tests in rats and mice.

    PubMed

    Castagné, Vincent; Moser, Paul; Roux, Sylvain; Porsolt, Roger D

    2011-04-01

    The development of antidepressants requires simple rodent behavioral tests for initial screening before undertaking more complex preclinical tests and clinical evaluation. Presented in the unit are two widely used screening tests used for antidepressants, the forced swim (also termed behavioral despair) test in the rat and mouse, and the tail suspension test in the mouse. These tests have good predictive validity and allow rapid and economical detection of substances with potential antidepressant-like activity. The behavioral despair and the tail suspension tests are based on the same principle: measurement of the duration of immobility when rodents are exposed to an inescapable situation. The majority of clinically used antidepressants decrease the duration of immobility. Antidepressants also increase the latency to immobility, and this additional measure can increase the sensitivity of the behavioral despair test in the mouse for certain classes of antidepressant. Testing of new substances in the behavioral despair and tail suspension tests allows a simple assessment of their potential antidepressant activity by the measurement of their effect on immobility. © 2011 by John Wiley & Sons, Inc.

  12. Simple, Inexpensive, and Rapid Way to Produce Bacillus subtilis Spores for the Guthrie Bioassay

    PubMed Central

    Franklin, Martha L.; Clark, William A.

    1981-01-01

    Esculin agar has been found to be a simple, inexpensive, rapid, and reliable means to promote production of spores of inhibitor-sensitive clones of Bacillus subtilis strains ATCC 6051 and 6633 for use in the Guthrie bioassay screening tests for genetic metabolic disorders. Images PMID:6790564

  13. Simplified three microphone acoustic test method

    USDA-ARS?s Scientific Manuscript database

    Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that could provide a quick comparison for rapid identifi...

  14. A comparison of an immunological faecal occult blood test Fecatwin sensitive/FECA EIA with Haemoccult in population screening for colorectal cancer.

    PubMed Central

    Armitage, N.; Hardcastle, J. D.; Amar, S. S.; Balfour, T. W.; Haynes, J.; James, P. D.

    1985-01-01

    Two faecal occult blood tests, a simple chemical test Haemoccult and an immunological test, Fecatwin Sensitive/Feca EIA, were offered to 3,225 asymptomatic individuals as screening for colorectal cancer. One thousand three hundred and four (44%) completed and returned the tests and of these 126 (9.7%) were found to be positive - Haemoccult 40 (3%) and Feca EIA 106 (8.1%). Five cancers (4 Dukes' Stage A, 1 Dukes' Stage C) and 23 adenomas greater than 1 cm were detected - rates of 3.8 per 1000 persons screened and 17.7 per 1000 persons screened respectively. Of the five cancers identified 5 were Feca EIA positive and 3 were Haemoccult positive. Of the 23 adenomas greater than 1 cm diameter identified, J1 were Feca EIA positive and 20 were Haemoccult positive. Seventy-eight Feca EIA positive subjects were investigated and no neoplastic disease was identified. Whilst this sensitive immunological test increases the yield of carcinomas, the high false positive rate makes it unsuitable for population screening for colorectal cancer in its present form. PMID:4005139

  15. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    PubMed

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  16. Proposal for a screening test to evaluate the fate of organic micropollutants in activated sludge.

    PubMed

    Salvetti, Roberta; Vismara, Renato; Dal Ben, Ilaria; Gorla, Elena; Romele, Laura

    2011-04-01

    The concentrations of organic micropollutants are usually low in wastewaters (order of magnitude of mg L(-1)). However, their emission standards, especially in the case of carcinogenic and bioaccumulating substances, are often much lower (order of magnitude of microg L(-1)). Since these substances, in some cases, can be adsorbable or volatile, their removal via volatilization, biodegradation or sludge adsorption in a wastewater treatment plant (WWTP) becomes a significant feature to include in the usual design process, in order to verify the emission standards in gas and sludge too. In this study a simple screening batch test for the evaluation of the fate of organic micropollutants in water, air and sludge is presented. The test is set up by means of simple laboratory instruments and simulates an activated sludge tank process. In this study the results obtained for four substances with different chemical properties (i.e. toluene, benz(a)anthracene, phenol and benzene) are presented. The screening test proposed can be a useful tool to assess in about one month the fate of organic micropollutants in an activated sludge tank of a WWTP. Moreover, the test can constitute a useful support in the use of mathematical models, since it allows the verification of model results and the calibration of the reactions involved in the removal process.

  17. Development and validation of Trivandrum Development Screening Chart for children aged 0-6 years [TDSC (0-6)].

    PubMed

    Nair, M K C; Nair, G S Harikumaran; George, Babu; Suma, N; Neethu, C; Leena, M L; Russell, Paul Swamidhas Sudhakar

    2013-11-01

    To develop and validate a simple screening tool for identifying developmental delay among children of 0-6 y of age in the community. The 51-items of Trivandrum Development Screening Chart for children of 0-6 y [TDSC (0-6 y)], were carefully prepared from the norms in various existing developmental charts/scales, by experts keeping in mind the face validity and content validity. The criterion validity was assessed in a community sample of 1,183 children of 0-6 y with a mean age of 35.38 mo (SD of 19.25) including 597 (50.46%) boys and 586 (49.54%) girls. TDSC (0-6 y) was validated against Denver Developmental Screening Test (DDST) as the 'Reference Standard'. When one item delay in TDSC (0-6 y) was considered as 'TDSC delay' (test positive), the sensitivity and specificity of TDSC (0-6 y) was found to be 84.62% (95% CI: 71.92-93.12) and 90.8% (95% CI: 88.97-92.43) respectively with a Negative Predictive Value of 99.23% (95% CI: 98.48-99.67) and LR (negative) of 0.17(95% CI: 0.09-0.32). The test-retest and inter-rater reliability [an interclass correlation (ICC) of 0.77 for test-retest and ICC of 0.97 for inter-rater] were good and acceptable. TDSC (0-6 y) is a simple, reliable and valid screening tool for use in the community to identify children between 0 and 6 y with developmental delay, enabling early intervention practices.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gratia, Pierre; Hu, Wayne; Enrico Fermi Institute and Kavli Institute for Cosmological Physics, University of Chicago,South Ellis Avenue, Chicago, IL 60637

    Attempts to modify gravity in the infrared typically require a screening mechanism to ensure consistency with local tests of gravity. These screening mechanisms fit into three broad classes; we investigate theories which are capable of exhibiting more than one type of screening. Specifically, we focus on a simple model which exhibits both Vainshtein and kinetic screening. We point out that due to the two characteristic length scales in the problem, the type of screening that dominates depends on the mass of the sourcing object, allowing for different phenomenology at different scales. We consider embedding this double screening phenomenology in amore » broader cosmological scenario and show that the simplest examples that exhibit double screening are radiatively stable.« less

  19. Experience of Routine Live-birth Screening for Galactosaemia in a British Hospital, with Emphasis on Heterozygote Detection

    PubMed Central

    Ellis, Graham; Wilcock, A. Ross; Goldberg, David M.

    1972-01-01

    Results are reported of a screening programme for galactosaemia covering a period of 2½ years and 6415 births. The gene frequency for galactosaemia estimated from the data of the screening programme was 0·002. This conflicted with the known live-birth incidence of at least 1: 50,000 during this same period. 2 of the 4 galactosaemic infants concerned died under circumstances that were preventable had they been screened at birth. The need to screen all sick infants for galactosaemia is emphasized, as is the requirement for reliable information on its incidence in Great Britain. The screening test employed (Beutler and Baluda, 1966a) seemed appropriate for this purpose. It was simple to perform and apparently accurate in galactosaemic infants. Its accuracy in detecting heterozygotes is uncertain. This test should be available in all hospitals receiving sick neonates. PMID:4401641

  20. A simple screening method using ion chromatography for the diagnosis of cerebral creatine deficiency syndromes.

    PubMed

    Wada, Takahito; Shimbo, Hiroko; Osaka, Hitoshi

    2012-08-01

    Cerebral creatine deficiency syndromes (CCDS) are caused by genetic defects in L-arginine:glycine amidinotransferase, guanidinoacetate methyltransferase or creatine transporter 1. CCDS are characterized by abnormal concentrations of urinary creatine (CR), guanidinoacetic acid (GA), or creatinine (CN). In this study, we describe a simple HPLC method to determine the concentrations of CR, GA, and CN using a weak-acid ion chromatography column with a UV detector without any derivatization. CR, GA, and CN were separated clearly with the retention times (mean ± SD, n = 3) of 5.54 ± 0.0035 min for CR, 6.41 ± 0.0079 min for GA, and 13.53 ± 0.046 min for CN. This new method should provide a simple screening test for the diagnosis of CCDS.

  1. Piezoelectric and Electrostrictive Materials for Transducer Applications.

    DTIC Science & Technology

    1984-05-01

    the stress is applied to sample using a simple lever arm to provide high load at the center point of a piston of hardened steel. To avoid poisson ratio...relatively simple ’screening test’ for PZT powders, powder samples were prepared from six different PZT transducer formulations supplied by the Navy...to 6000C showed the largest broadening. Heat treatment of this sample to 1.1000C reduced the broadening markedly indicating that simple chemical co

  2. Self testing for diabetes mellitus.

    PubMed Central

    Davies, M; Alban-Davies, H; Cook, C; Day, J

    1991-01-01

    OBJECTIVE--To develop a simple, economically viable, and effective means of population screening for diabetes mellitus. DESIGN--A postal request system for self testing for glycosuria with foil wrapped dipsticks. Preprandial and postprandial tests were compared with a single postprandial test. The subjects were instructed how to test, and a result card was supplied on which to record and return the result. All those recording a positive test result and 50 people recording a negative result were invited for an oral glucose tolerance test. SETTING--General practice in east Suffolk, list size 11534. PATIENTS--All subjects aged 45-70 years registered with the practice were identified by Suffolk Family Health Services Authority (n = 3057). The 73 subjects known to have diabetes from the practice's register were excluded, leaving 2984 subjects, 2363 (79.2%) of whom responded. 1167 subjects completed the single test and 1196 the two tests. MAIN OUTCOME MEASURES--Response rate and number of patients with glycosuria. Sensitivity, specificity, and positive predictive value of a single postprandial test and preprandial and postprandial tests. Number of new cases of diabetes identified and cost of screening. RESULTS--Of the patients completing the single postprandial test, 29 had a positive result, an oral glucose tolerance test showed that eight (28%) had diabetes, six (21%) impaired glucose tolerance, and 14 (48%) normal glucose tolerance. 44 of the group who tested before and after eating had a positive result; nine (20%) had diabetes, five (11%) impaired tolerance, and 26 (11%) normal tolerance. Screening cost 59p per subject and 81 pounds per case detected. Of the 17 people with previously undiagnosed diabetes, eight were asymptomatic and 11 had not visited their general practitioner in the past three months. CONCLUSIONS--A postal request system for self testing for postprandial glycosuria in people aged 45-70 is a simple and effective method of population screening for diabetes mellitus. PMID:1912918

  3. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Simplified through-transmission test method for determination of a material's acoustic properties

    USDA-ARS?s Scientific Manuscript database

    Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that can provide a quick comparison for rapid identifica...

  5. Rapid screening test for gestational diabetes: public health need, market requirement, initial product design, and experimental results

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth

    2013-03-01

    Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.

  6. Accurate screening for insulin resistance in PCOS women using fasting insulin concentrations.

    PubMed

    Lunger, Fabian; Wildt, Ludwig; Seeber, Beata

    2013-06-01

    The aims of this cross-sectional study were to evaluate the relative agreement of both static and dynamic methods of diagnosing IR in women with polycystic ovary syndrome (PCOS) and to suggest a simple screening method for IR. All participants underwent serial blood draws for hormonal profiling and lipid assessment, a 3 h, 75 g load oral glucose tolerance test (OGTT) with every 15 min measurements of glucose and insulin, and an ACTH stimulation test. The prevalence of IR ranged from 12.2% to 60.5%, depending on the IR index used. Based on largest area under the curve on receiver operating curve (ROC) analyses, the dynamic indices outperformed the static indices with glucose to insulin ratio and fasting insulin (fInsulin) demonstrating the best diagnostic properties. Applying two cut-offs representing fInsulin extremes (<7 and >13 mIU/l, respectively) gave the diagnosis in 70% of the patients with high accuracy. Currently utilized indices for assessing IR give highly variable results in women with PCOS. The most accurate indices based on dynamic testing can be time-consuming and labor-intensive. We suggest the use of fInsulin as a simple screening test, which can reduce the number of OGTTs needed to routinely assess insulin resistance in women with PCOS.

  7. Identifying Autism with a Brief and Low-Cost Screening Instrument--OERA: Construct Validity, Invariance Testing, and Agreement between Judges

    ERIC Educational Resources Information Center

    Paula, Cristiane S.; Cunha, Graccielle Rodrigues; Bordini, Daniela; Brunoni, Decio; Moya, Ana Claudia; Bosa, Cleonice Alves; Mari, Jair J.; Cogo-Moreira, Hugo

    2018-01-01

    Simple and low-cost observational-tools to detect symptoms of Autism Spectrum Disorder (ASD) are still necessary. The OERA is a new assessment tool to screen children eliciting observable behaviors with no substantial knowledge on ASD required. The sample was 99 children aged 3-10: 76 with ASD and 23 without ASD (11/23 had intellectual…

  8. Suppression of background noise in a transonic wind-tunnel test section

    NASA Technical Reports Server (NTRS)

    Schutzenhofer, L. A.; Howard, P. W.

    1975-01-01

    Some exploratory tests were recently performed in the transonic test section of the NASA Marshall Space Flight Center 14-in. wind tunnel to suppress the background noise. In these tests, the perforated walls of the test section were covered with fine wire screens. The screens eliminated the edge tones generated by the holes in the perforated walls and significantly reduced the tunnel background noise. The tunnel noise levels were reduced to such a degree by this simple modification at Mach numbers 0.75, 0.9, 1.1, 1.2, and 1.46 that the fluctuating pressure levels of a turbulent boundary layer could be measured on a 5-deg half-angle cone.

  9. Development and validation of the Salzburg COPD-screening questionnaire (SCSQ): a questionnaire development and validation study.

    PubMed

    Weiss, Gertraud; Steinacher, Ina; Lamprecht, Bernd; Kaiser, Bernhard; Mikes, Romana; Sator, Lea; Hartl, Sylvia; Wagner, Helga; Studnicka, M

    2017-01-26

    Chronic obstructive pulmonary disease prevalence rates are still high. However, the majority of subjects are not diagnosed. Strategies have to be implemented to overcome the problem of under-diagnosis. Questionnaires could be used to pre-select subjects for spirometry and thereby help reducing under-diagnosis. We report a brief, simple, self-administrable and validated chronic obstructive pulmonary disease questionnaire to increase the pre-test probability for chronic obstructive pulmonary disease diagnosis in subjects undergoing confirmatory spirometry. In 2005, we completed the Austrian Burden of Obstructive Lung Disease-study in 1258 subjects aged >40 years. Post-bronchodilator spirometry was performed, and non-reversible airflow limitation defined by FEV 1 /FVC ratio below the lower limit of normal. Questions from the Salzburg chronic obstructive pulmonary disease screening-questionnaire were selected using a logistic regression model, and risk scores were based on regression-coefficients. A training sub-sample (n = 800) was used to create the score, and a test sub-sample (n = 458) was used to test it. In 2008, an external validation study was done, using the same protocol in 775 patients from primary care. The Salzburg chronic obstructive pulmonary disease screening questionnaire was composed of items related to "breathing problems", "wheeze", "cough", "limitation of physical activity", and "smoking". At the >=2 points cut-off of the Salzburg chronic obstructive pulmonary disease screening questionnaire, sensitivity was 69.1% [95%CI: 56.6%; 79.5%], specificity 60.0% [95%CI: 54.9%; 64.9%], the positive predictive value 23.2% [95%CI: 17.7%; 29.7%] and the negative predictive value 91.8% [95%CI: 87.5%; 95.7%] to detect post bronchodilator airflow limitation. The external validation study in primary care confirmed these findings. The Salzburg chronic obstructive pulmonary disease screening questionnaire was derived from the highly standardized Burden of Obstructive Lung Disease study. This validated and easy to use questionnaire can help to increase the efficiency of chronic obstructive pulmonary disease case-finding. QUESTIONNAIRE FOR PRE-SCREENING POTENTIAL SUFFERERS: Scientists in Austria have developed a brief, simple questionnaire to identify patients likely to have early-stage chronic lung disease. Chronic obstructive pulmonary disease (COPD) is notoriously difficult to diagnose, and the condition often causes irreversible lung damage before it is identified. Finding a simple, cost-effective method of pre-screening patients with suspected early-stage COPD could potentially improve treatment responses and limit the burden of extensive lung function ('spirometry') tests on health services. Gertraud Weiss at Paracelsus Medical University, Austria, and co-workers have developed and validated an easy-to-use, self-administered questionnaire that could prove effective for pre-screening patients. The team trialed the five-point Salzburg COPD-screening questionnaire on 1258 patients. Patients scoring 2 points or above on the questionnaire underwent spirometry tests. The questionnaire seems to provide a sensitive and cost-effective way of pre-selecting patients for spirometry referral.

  10. Further statistics in dentistry, Part 5: Diagnostic tests for oral conditions.

    PubMed

    Petrie, A; Bulman, J S; Osborn, J F

    2002-12-07

    A diagnostic test is a simple test, sometimes based on a clinical measurement, which is used when the gold-standard test providing a definitive diagnosis of a given condition is too expensive, invasive or time-consuming to perform. The diagnostic test can be used to diagnose a dental condition in an individual patient or as a screening device in a population of apparently healthy individuals.

  11. Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing.

    PubMed

    Ge, Lei; Yan, Jixian; Song, Xianrang; Yan, Mei; Ge, Shenguang; Yu, Jinghua

    2012-02-01

    In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (μPADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on μPAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (Ⅱ) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable μPAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Correlates of Harmful Alcohol Consumption in Six Countries: Development of an International Screening and Assessment Procedure.

    ERIC Educational Resources Information Center

    Aasland, Olaf Gjerlow; and Others

    The aim of this study was to develop tools for screening and assessment of socio-medical effects of alcohol use which are simple and inexpensive enough to be used in any primary health care setting. A test protocol was prepared by a group of investigators from Australia, Bulgaria, Kenya, Mexico, Norway, and the United States. Based on a number of…

  13. Diagnosis of ocular and glandular toxoplasmosis using the Indian ink immunoreaction.

    PubMed

    Safar, E H; Azab, M E; Osman, Z M

    1984-01-01

    The Indian ink immunoreaction (IIR) as a method for diagnosis of Toxoplasma infection has been evaluated. 68 sera from patients with suspected ocular and glandular toxoplasmosis and 30 control sera from normal individuals were tested using both indirect fluorescent antibody test (IFAT) and IIR. The test proved to be specific, simple and rapid especially for screening purposes.

  14. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. [Screening for psychiatric risk factors in a facial trauma patients. Validating a questionnaire].

    PubMed

    Foletti, J M; Bruneau, S; Farisse, J; Thiery, G; Chossegros, C; Guyot, L

    2014-12-01

    We recorded similarities between patients managed in the psychiatry department and in the maxillo-facial surgical unit. Our hypothesis was that some psychiatric conditions act as risk factors for facial trauma. We had for aim to test our hypothesis and to validate a simple and efficient questionnaire to identify these psychiatric disorders. Fifty-eight consenting patients with facial trauma, recruited prospectively in the 3 maxillo-facial surgery departments of the Marseille area during 3 months (December 2012-March 2013) completed a self-questionnaire based on the French version of 3 validated screening tests (Self Reported Psychopathy test, Rapid Alcohol Problem Screening test quantity-frequency, and Personal Health Questionnaire). This preliminary study confirmed that psychiatric conditions detected by our questionnaire, namely alcohol abuse and dependence, substance abuse, and depression, were risk factors for facial trauma. Maxillo-facial surgeons are often unaware of psychiatric disorders that may be the cause of facial trauma. The self-screening test we propose allows documenting the psychiatric history of patients and implementing earlier psychiatric care. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  16. Field tests of diffusion samplers for inorganic constituents in wells and at a ground-water discharge zone

    USGS Publications Warehouse

    Vroblesky, Don A.; Petkewich, Matthew D.; Campbell, Ted R.

    2002-01-01

    Field tests were performed on two types of diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. Nylon-screen samplers and dialysis samplers were tested for the collection of arsenic, calcium, chloride, iron, manganese, sulfate, and dissolved oxygen. The investigations were conducted at the Naval Industrial Reserve Ordnance Plant (NIROP), Fridley, Minnesota, and at the Naval Air Station Fort Worth Joint Reserve Base (NAS Fort Worth JRB), Texas. Data indicate that, in general, nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water that correspond to concentrations obtained by low-flow sampling. Diffusion samplers offer a potentially time-saving approach to well sampling. Particular care must be taken, however, when sampling for iron and other metals, because of the potential for iron precipitation by oxygenation and when dealing with chemically stratified sampling intervals. Simple nylon-screen jar samplers buried beneath creekbed sediment appear to be effective tools for locating discharge zones of arsenic contaminated ground water. Although the LDPE samplers have proven to be inexpensive and simple to use in wells, they are limited by their inability to provide a representative sample of ionic solutes. The success of nylon-screen samplers in sediment studies suggests that these simple samplers may be useful for collecting water samples for inorganic constituents in wells. Results using dialysis bags deployed in wells suggest that these types of samplers have the potential to provide a representative sample of both VOCs and ionic solutes from ground water (Kaplan and others, 1991; Theodore A. Ehlke, U.S. Geological Survey, written commun., 2001). The purpose of this report is to provide results of field tests investigating the potential to use diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. The investigations were performed at NIROP, Fridley, Minn. (fig. 1) and at NAS Fort Worth JRB, Texas (fig. 2). Two types of samplers were tested. One type was a nylon-screen sampler, which consisted of a 30-mL jar filled with deionized water, with its opening covered by a nylon screen. The second type was a dialysis sampler that consisted of a tube of dialysis membrane filled with deionized water. The nylon-screen samplers were deployed in wells at NIROP Fridley and NAS Fort Worth JRB and beneath the ground-water/surface water interface of a stream at NAS Fort Worth JRB. The dialysis samplers were deployed only in wells at NAS Fort Worth JRB.

  17. Neuroleptics as therapeutic compounds stabilizing neuromuscular transmission in amyotrophic lateral sclerosis

    PubMed Central

    Patten, Shunmoogum A.; Aggad, Dina; Martinez, Jose; Tremblay, Elsa; Petrillo, Janet; Armstrong, Gary A.B.; Maios, Claudia; Liao, Meijiang; Ciura, Sorana; Wen, Xiao-Yan; Rafuse, Victor; Ichida, Justin; Zinman, Lorne; Julien, Jean-Pierre; Kabashi, Edor; Robitaille, Richard; Korngut, Lawrence; Parker, J. Alexander

    2017-01-01

    Amyotrophic lateral sclerosis (ALS) is a rapidly progressing, fatal disorder with no effective treatment. We used simple genetic models of ALS to screen phenotypically for potential therapeutic compounds. We screened libraries of compounds in C. elegans, validated hits in zebrafish, and tested the most potent molecule in mice and in a small clinical trial. We identified a class of neuroleptics that restored motility in C. elegans and in zebrafish, and the most potent was pimozide, which blocked T-type Ca2+ channels in these simple models and stabilized neuromuscular transmission in zebrafish and enhanced it in mice. Finally, a short randomized controlled trial of sporadic ALS subjects demonstrated stabilization of motility and evidence of target engagement at the neuromuscular junction. Simple genetic models are, thus, useful in identifying promising compounds for the treatment of ALS, such as neuroleptics, which may stabilize neuromuscular transmission and prolong survival in this disease. PMID:29202456

  18. Neuroleptics as therapeutic compounds stabilizing neuromuscular transmission in amyotrophic lateral sclerosis.

    PubMed

    Patten, Shunmoogum A; Aggad, Dina; Martinez, Jose; Tremblay, Elsa; Petrillo, Janet; Armstrong, Gary Ab; La Fontaine, Alexandre; Maios, Claudia; Liao, Meijiang; Ciura, Sorana; Wen, Xiao-Yan; Rafuse, Victor; Ichida, Justin; Zinman, Lorne; Julien, Jean-Pierre; Kabashi, Edor; Robitaille, Richard; Korngut, Lawrence; Parker, J Alexander; Drapeau, Pierre

    2017-11-16

    Amyotrophic lateral sclerosis (ALS) is a rapidly progressing, fatal disorder with no effective treatment. We used simple genetic models of ALS to screen phenotypically for potential therapeutic compounds. We screened libraries of compounds in C. elegans, validated hits in zebrafish, and tested the most potent molecule in mice and in a small clinical trial. We identified a class of neuroleptics that restored motility in C. elegans and in zebrafish, and the most potent was pimozide, which blocked T-type Ca2+ channels in these simple models and stabilized neuromuscular transmission in zebrafish and enhanced it in mice. Finally, a short randomized controlled trial of sporadic ALS subjects demonstrated stabilization of motility and evidence of target engagement at the neuromuscular junction. Simple genetic models are, thus, useful in identifying promising compounds for the treatment of ALS, such as neuroleptics, which may stabilize neuromuscular transmission and prolong survival in this disease.

  19. Selective solvent-free chromium detection using cadmium-free quantum dots

    NASA Astrophysics Data System (ADS)

    Meylemans, Heather A.; Baca, Alfred J.; Cambrea, Lee R.; Ostrom, Gregory S.

    2017-07-01

    Currently, the method of choice to test for the presence of chromium in water is to submit samples to a lab for testing. We present a simple field-ready test that is selective for the presence of chromium at concentrations of 100 ppb or greater. The Environmental Protection Agency maximum contaminant level (MCL) for total chromium is 100 ppb. This test uses a simple on/off fluorescent screening employing the use of silver indium sulfide (AgInS2) quantum dots (QDs). These QDs were impregnated into cotton pads to simplify field testing without the need for solvents or other liquid chemicals to be present. The change in fluorescence is instant and can be readily observed by eye with the use of a UV flashlight.

  20. Urinary cotinine testing as pre-operative assessment of patients undergoing free flap surgery.

    PubMed

    Reinbold, C; Rausky, J; Binder, J-P; Revol, M

    2015-02-01

    The identified risks of smoking with regard to operated tissues are so elevated that it is clearly dangerous to operate a smoker when the proposed intervention is neither vital nor urgent. The aim of this prospective study was to evaluate a simple method of screening patients who smoke, with the evaluation carried out before agreeing to carry out free tissue transfer. The purpose of the testing was to hold the patient responsible for his actions and minimize smoking-related complications by cancelling or postponing the planned operation if the patient continued to smoke. Screening included use of a standardized questionnaire at the first consultation and detection of cotinine using a urine test strip 7 days before the scheduled surgery. Patients were informed that in the event of positive results, the operation would not take place. A six-week preoperative smoking cessation period was mandatory. Seventy-six patients were included in this study. Among them, 25 (32.9%) reported being former smokers and 11 (14.5%) admitted in the initial questionnaire to being active smokers. Six patients (7.9%), including one self-reported non-smoker, tested positive for cotinine, and their operations were cancelled. Screening using a questionnaire and cotinine detection appeared to constitute a simple, inexpensive, rapid and reliable test. It allowed us to refuse to operate 6 non-compliant patients and was thereby likely to diminish morbidity in the free tissue transfers carried out in our ward. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    PubMed Central

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  2. Minimally invasive screening for colitis using attenuated total internal reflectance Fourier transform infrared spectroscopy

    PubMed Central

    Titus, Jitto; Viennois, Emilie; Merlin, Didier; Perera, A. G. Unil

    2016-01-01

    This article describes a rapid, simple and cost-effective technique that could lead to a screening method for colitis without the need for biopsies or in vivo measurements. This screening technique includes the testing of serum using Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) spectroscopy for the colitis-induced increased presence of mannose. Chronic (Interleukin 10 knockout) and acute (Dextran Sodium Sulphate-induced) models for colitis are tested using the ATR-FTIR technique. Arthritis (Collagen Antibody Induced Arthritis) and metabolic syndrome (Toll like receptor 5 knockout) models are also tested as controls. The marker identified as mannose uniquely screens and distinguishes the colitic from the non-colitic samples and the controls. The reference or the baseline spectrum could be the pooled and averaged spectra of non-colitic samples or the subject's previous sample spectrum. This shows the potential of having individualized route maps of disease status, leading to personalized diagnosis and drug management. PMID:27094092

  3. [Screening for diabetes in France: data from the 2000-2001 cohort of the national medical insurance system].

    PubMed

    Hirtzlin, I; Fagot-Campagna, A; Girard-Le Gallo, I; Vallier, N; Poutignat, N; Weill, A; Le Laidier, S

    2004-04-01

    Type 2 diabetes mellitus may go undiagnosed for several Years while complications are silently developing. In France, from 2 to 3.7% of adults aged 35-65 are unaware they have diabetes. Nevertheless fasting serum glucose is a simple diagnostic test. We described people who underwent opportunist diabetes screening (serum glucose) within 2 Years (2000-2001). We used the administrative EPAS cohort from the employee National Health Insurance System which covers 70% of the total population in France. The data are based on reimbursements of glucose testing and hospitalization among people who did not received reimbursements of treatment for diabetes but used medical services during the 2 Years. The opportunistic screening rate within 2 Years was 48.6% overall and increased with age. Among those 45 Years old or older, it was 71.2%. The screening rate was higher among women than men. Opportunistic screening for diabetes is commonly practised in France, despite the lack of official guidelines. Several hypotheses may explain the discrepancy between common opportunist screening and high prevalence of undiagnosed diabetes: 1). undiagnosed diabetes is mostly present in people who do not use medical services; 2). opportunistic screening is not performed among the most at-risk population; 3). testing is not performed on fasting samples or results are neglected; 4). results of testing are overlooked by doctors/patients; 5). epidemiological studies based on self-report of diagnosis and only one testing overestimate undiagnosed diabetes.

  4. CT colonography: accuracy, acceptance, safety and position in organised population screening.

    PubMed

    de Haan, Margriet C; Pickhardt, Perry J; Stoker, Jaap

    2015-02-01

    Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. The introduction of CRC screening programmes using stool tests and flexible sigmoidoscopy, have been shown to reduce CRC-related mortality substantially. In several European countries, population-based CRC screening programmes are ongoing or being rolled out. Stool tests like faecal occult blood testing are non-invasive and simple to perform, but are primarily designed to detect early invasive cancer. More invasive tests like colonoscopy and CT colonography (CTC) aim at accurately detecting both CRC and cancer precursors, thus providing for cancer prevention. This review focuses on the accuracy, acceptance and safety of CTC as a CRC screening technique and on the current position of CTC in organised population screening. Based on the detection characteristics and acceptability of CTC screening, it might be a viable screening test. The potential disadvantage of radiation exposure is probably overemphasised, especially with newer technology. At this time-point, it is not entirely clear whether the detection of extracolonic findings at CTC is of net benefit and is cost effective, but with responsible handling, this may be the case. Future efforts will seek to further improve the technique, refine appropriate diagnostic algorithms and study cost-effectiveness. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Towards Risk-Based Test Protocols: Estimating the Contribution of Intensive Testing to the UK Bovine Tuberculosis Problem

    PubMed Central

    van Dijk, Jan

    2013-01-01

    Eradicating disease from livestock populations involves the balancing act of removing sufficient numbers of diseased animals without removing too many healthy individuals in the process. As ever more tests for bovine tuberculosis (BTB) are carried out on the UK cattle herd, and each positive herd test triggers more testing, the question arises whether ‘false positive’ results contribute significantly to the measured BTB prevalence. Here, this question is explored using simple probabilistic models of test behaviour. When the screening test is applied to the average UK herd, the estimated proportion of test-associated false positive new outbreaks is highly sensitive to small fluctuations in screening test specificity. Estimations of this parameter should be updated as a priority. Once outbreaks have been confirmed in screening-test positive herds, the following rounds of intensive testing with more sensitive, albeit less specific, tests are highly likely to remove large numbers of false positive animals from herds. Despite this, it is unlikely that significantly more truly infected animals are removed. BTB test protocols should become based on quantified risk in order to prevent the needless slaughter of large numbers of healthy animals. PMID:23717517

  6. Sex workers can be screened too often: a cost-effectiveness analysis in Victoria, Australia.

    PubMed

    Wilson, David P; Heymer, Kelly-Jean; Anderson, Jonathan; O'Connor, Jody; Harcourt, Christine; Donovan, Basil

    2010-04-01

    Commercial sex is licensed in Victoria, Australia such that sex workers are required to have regular tests for sexually transmitted infections (STIs). However, the incidence and prevalence of STIs in sex workers are very low, especially since there is almost universal condom use at work. We aimed to conduct a cost-effectiveness analysis of the financial cost of the testing policy versus the health benefits of averting the transmission of HIV, syphilis, chlamydia and gonorrhoea to clients. We developed a simple mathematical transmission model, informed by conservative parameter estimates from all available data, linked to a cost-effectiveness analysis. We estimated that under current testing rates, it costs over $A90,000 in screening costs for every chlamydia infection averted (and $A600,000 in screening costs for each quality-adjusted life year (QALY) saved) and over $A4,000,000 for every HIV infection averted ($A10,000,000 in screening costs for each QALY saved). At an assumed willingness to pay of $A50,000 per QALY gained, HIV testing should not be conducted less than approximately every 40 weeks and chlamydia testing approximately once per year; in comparison, current requirements are testing every 12 weeks for HIV and every 4 weeks for chlamydia. Mandatory screening of female sex workers at current testing frequencies is not cost-effective for the prevention of disease in their male clients. The current testing rate required of sex workers in Victoria is excessive. Screening intervals for sex workers should be based on local STI epidemiology and not locked by legislation.

  7. [A new system of testing visual performance based on the cylindrical lens screen].

    PubMed

    Doege, E; Krause, O

    1983-09-01

    Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.

  8. ecode - Electron Transport Algorithm Testing v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Franke, Brian C.; Olson, Aaron J.; Bruss, Donald Eugene

    2016-10-05

    ecode is a Monte Carlo code used for testing algorithms related to electron transport. The code can read basic physics parameters, such as energy-dependent stopping powers and screening parameters. The code permits simple planar geometries of slabs or cubes. Parallelization consists of domain replication, with work distributed at the start of the calculation and statistical results gathered at the end of the calculation. Some basic routines (such as input parsing, random number generation, and statistics processing) are shared with the Integrated Tiger Series codes. A variety of algorithms for uncertainty propagation are incorporated based on the stochastic collocation and stochasticmore » Galerkin methods. These permit uncertainty only in the total and angular scattering cross sections. The code contains algorithms for simulating stochastic mixtures of two materials. The physics is approximate, ranging from mono-energetic and isotropic scattering to screened Rutherford angular scattering and Rutherford energy-loss scattering (simple electron transport models). No production of secondary particles is implemented, and no photon physics is implemented.« less

  9. Using Relative Statistics and Approximate Disease Prevalence to Compare Screening Tests.

    PubMed

    Samuelson, Frank; Abbey, Craig

    2016-11-01

    Schatzkin et al. and other authors demonstrated that the ratios of some conditional statistics such as the true positive fraction are equal to the ratios of unconditional statistics, such as disease detection rates, and therefore we can calculate these ratios between two screening tests on the same population even if negative test patients are not followed with a reference procedure and the true and false negative rates are unknown. We demonstrate that this same property applies to an expected utility metric. We also demonstrate that while simple estimates of relative specificities and relative areas under ROC curves (AUC) do depend on the unknown negative rates, we can write these ratios in terms of disease prevalence, and the dependence of these ratios on a posited prevalence is often weak particularly if that prevalence is small or the performance of the two screening tests is similar. Therefore we can estimate relative specificity or AUC with little loss of accuracy, if we use an approximate value of disease prevalence.

  10. Timing of testing and treatment for asymptomatic diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kırkızlar, Eser; Faissol, Daniel M.; Griffin, Paul M.

    2010-07-01

    Many papers in the medical literature analyze the cost-effectiveness of screening for diseases by comparing a limited number of a priori testing policies under estimated problem parameters. However, this may be insufficient to determine the best timing of the tests or incorporate changes over time. In this paper, we develop and solve a Markov Decision Process (MDP) model for a simple class of asymptomatic diseases in order to provide the building blocks for analysis of a more general class of diseases. We provide a computationally efficient method for determining a cost-effective dynamic intervention strategy that takes into account (i) themore » results of the previous test for each individual and (ii) the change in the individual’s behavior based on awareness of the disease. We demonstrate the usefulness of the approach by applying the results to screening decisions for Hepatitis C (HCV) using medical data, and compare our findings to current HCV screening recommendations.« less

  11. Towards Automated Screening of Two-dimensional Crystals

    PubMed Central

    Cheng, Anchi; Leung, Albert; Fellmann, Denis; Quispe, Joel; Suloway, Christian; Pulokas, James; Carragher, Bridget; Potter, Clinton S.

    2007-01-01

    Screening trials to determine the presence of two-dimensional (2D) protein crystals suitable for three-dimensional structure determination using electron crystallography is a very labor-intensive process. Methods compatible with fully automated screening have been developed for the process of crystal production by dialysis and for producing negatively stained grids of the resulting trials. Further automation via robotic handling of the EM grids, and semi-automated transmission electron microscopic imaging and evaluation of the trial grids is also possible. We, and others, have developed working prototypes for several of these tools and tested and evaluated them in a simple screen of 24 crystallization conditions. While further development of these tools is certainly required for a turn-key system, the goal of fully automated screening appears to be within reach. PMID:17977016

  12. Use of claims data to estimate annual cervical cancer screening percentages in Portland metropolitan area, Oregon.

    PubMed

    Abdullah, Nasreen; Laing, Robert S; Hariri, Susan; Young, Collette M; Schafer, Sean

    2016-04-01

    Human papillomavirus (HPV) vaccine should reduce cervical dysplasia before cervical cancer. However, dysplasia diagnosis is screening-dependent. Accurate screening estimates are needed. To estimate the percentage of women in a geographic population that has had cervical cancer screening. We analyzed claims data for (Papanicolau) Pap tests from 2008-2012 to estimate the percentage of insured women aged 18-39 years screened. We estimated screening in uninsured women by dividing the percentage of insured Behavioral Risk Factor Surveillance Survey respondents reporting previous-year testing by the percentage of uninsured respondents reporting previous-year testing, and multiplying this ratio by claims-based estimates of insured women with previous-year screening. We calculated a simple weighted average of the two estimates to estimate overall screening percentage. We estimated credible intervals using Monte-Carlo simulations. During 2008-2012, an annual average of 29.6% of women aged 18-39 years were screened. Screening increased from 2008 to 2009 in all age groups. During 2009-2012, the screening percentages decreased for all groups, but declined most in women aged 18-20 years, from 21.5% to 5.4%. Within age groups, compared to 2009, credible intervals did not overlap during 2011 (except age group 21-29 years) and 2012, and credible intervals in the 18-20 year group did not overlap with older groups in any year. This introduces a novel method to estimate population-level cervical cancer screening. Overall, percentage of women screened in Portland, Oregon fell following changes in screening recommendations released in 2009 and later modified in 2012. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Comparison of 1 mg and 2 mg overnight dexamethasone suppression tests for the screening of Cushing's syndrome in obese patients.

    PubMed

    Sahin, Mustafa; Kebapcilar, Levent; Taslipinar, Abdullah; Azal, Omer; Ozgurtas, Taner; Corakci, Ahmet; Akgul, Emin Ozgur; Taslipinar, Mine Yavuz; Yazici, Mahmut; Kutlu, Mustafa

    2009-01-01

    Obesity is currently a major public health problem and one of the potential underlying causes of obesity in a minority of patients is Cushing's syndrome (CS). Traditionally, the gold standard screening test for CS is 1 mg dexamethasone overnight suppression test. However, it is known that obese subjects have high false positive results with this test. We have therefore compared the 1 mg and 2 mg overnight dexamethasone suppression tests in obese subjects. Patients whose serum cortisol after ODST was >50 nM underwent and a low-dose dexamethasone suppression test (LDDST); 24-hour urine cortisol was collected for basal urinary free cortisol (UFC). For positive results after overnight 1-mg dexamethasone suppression test we also performed the overnight 2-mg dexamethasone suppression test. We prospectively evaluated 100 patients (22 men and 78 women, ranging in age from 17 to 73 years with a body mass index (BMI) >30 kg/m2 who had been referred to our hospital-affiliated endocrine clinic because of simple obesity. Suppression of serum cortisol to <50 nM (1.8 microg/dL) after dexamethasone administration was chosen as the cut-off point for normal suppression. Thyroid function tests, lipid profiles, homocysteine, antithyroglobulin, anti-thyroid peroxidase antibody levels, vitamin B12, folate levels, insulin resistance [by homeostasis model assessment (HOMA)] and 1.0 mg postdexamethasone (postdex) suppression cortisol levels were measured. We found an 8% false-positive rate in 1 mg overnight test and 2% in 2 mg overnight test (p=0.001). There was no correlation between the cortisol levels after ODST and other parameters. Our results indicate that the 2 mg overnight dexamethasone suppression test (ODST) is more convenient and accurate than 1-mg ODST as a screening test for excluding CS in subjects with simple obesity.

  14. A Targeted Swallow Screen for the Detection of Postoperative Dysphagia.

    PubMed

    Gee, Erica; Lancaster, Elizabeth; Meltzer, Jospeh; Mendelsohn, Abie H; Benharash, Peyman

    2015-10-01

    Postoperative dysphagia leads to aspiration pneumonia, prolonged hospital stay, and is associated with increased mortality. A simple and sensitive screening test to identify patients requiring objective dysphagia evaluation is presently lacking. In this study, we evaluated the efficacy of a novel targeted swallow screen evaluation. This was a prospective trial involving all adult patients who underwent elective cardiac surgery with cardiopulmonary bypass at our institution over an 8-week period. Within 24 hours of extubation and before the initiation of oral intake, all postsurgical patients were evaluated using the targeted swallow screen. A fiberoptic endoscopic evaluation of swallowing was requested for failed screenings. During the study, 50 postcardiac surgery patients were screened. Fifteen (30%) failed the targeted swallow screen, and ten of the fifteen (66%) failed the subsequent fiberoptic endoscopic evaluation of swallowing exam and were confirmed to have dysphagia. The screening test had 100 per cent sensitivity for detecting dysphagia in our patient population, and a specificity of 87.5 per cent. The overall incidence of dysphagia was 20 per cent. We have shown that a targeted swallow evaluation can efficiently screen patients during the postcardiac surgery period. Furthermore, we have shown that the true incidence of dysphagia after cardiac surgery is significantly higher than previously recognized in literature.

  15. Perceptions of exercise screening among older adults.

    PubMed

    Stathokostas, Liza; Petrella, Andrea F M; Blunt, Wendy; Petrella, Robert J

    2018-06-01

    Prephysical activity screening is important for older adults' participating in physical activity. Unfortunately, many older adults face barriers to exercise participation and thus, may not complete proper physical activity screening. The purpose of this project was to conduct a thematic analysis of perceptions and experiences of community-dwelling older adults regarding prephysical activity screening (i.e., Get Active Questionnaire (GAQ) and a standardized exercise stress test). A convenience sample of adults (male n = 58, female n = 54) aged 75 ± 7 years living in the City of London, Ontario, Canada, was used. Participants completed a treadmill stress test and the GAQ at a research laboratory for community-based referrals. One week later, participants completed the GAQ again and were asked questions by a research assistant about their perceptions of the screening process. Thematic analysis of the responses was conducted. The results indicated that older adults view physical activity screening as acceptable, but not always necessary. Also, the experiences expressed by this sample of older adults indicated that physical activity screening can contribute to continued confidence (through reassurance) and can contribute to increased motivation (through yearly fitness results) in exercise participation. In conclusion, older adults may perceive screening as supportive in exercise adoption, if screening is simple, convenient, and supports older adults' motivation and confidence to exercise.

  16. Design and construction of a tensile tester for the testing of simple composites

    NASA Technical Reports Server (NTRS)

    Borst, Mark A.; Spiegel, F. Xavier

    1994-01-01

    The following is a design for a tensile tester which will be used to test the tensile strength and anisotropic properties of simple composites. These simple composites are suspected to be anisotropic primarily in a single plane. When the composites undergo a tensile force, they will undergo deformation, causing movement either to the left or right. The composites are suspect due to their method of construction. Each sample has a single layer of unidirectional continuous fibers embedded in a rubbery resin. It has been well established that a serious limitation of unidirectional fiber composites is the very large in-plane anisotropy. The design presented here incorporates a single degree of freedom such that distortion (to the left or right) due to anisotropic tendencies may be measured. The device will spend the vast majority of its time in an undergraduate materials lab. As a result, ease of use and durability are valued more highly than research grade accuracy. Additional concerns focus on the fact that this machine will be built as a student project. Issues which are dealt with during this design include: specimen configuration or shape; a method of applying consistent, linear tension force; a method of gripping specimen without affecting its overall properties; a method of collecting data; repeatability of data; ease of use; ease of construction; and cost. After the device has been constructed, it will be used to test the simple composites which were fabricated in house. A comparison will be made between composites manufactured using aluminum screening as the strengthening fibers and those manufactured using fiberglass screening.

  17. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    PubMed

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  18. Do doctors understand the test characteristics of lung cancer screening?

    PubMed

    Schmidt, Richard; Breyer, Marie; Breyer-Kohansal, Robab; Urban, Matthias; Funk, Georg-Christian

    2018-04-01

    Screening for lung cancer with a low-dose computed tomography (CT) scan is estimated to prevent 3 deaths per 1000 individuals at high risk; however, false positive results and radiation exposure are relevant harms and deserve careful consideration. Screening candidates can only make an autonomous decision if doctors correctly inform them of the pros and cons of the method; therefore, this study aimed to evaluate whether doctors understand the test characteristics of lung cancer screening. In a randomized trial 556 doctors (members of the Austrian Respiratory Society) were invited to answer questions regarding lung cancer screening based on online case vignettes. Half of the participants were randomized to the group 'solutions provided' and received the correct solutions in advance. The group 'solutions withheld' had to rely on prior knowledge or estimates. The primary endpoint was the between-group difference in the estimated number of deaths preventable by screening. Secondary endpoints were the between-group differences in the prevalence of lung cancer, prevalence of a positive screening results, sensitivity, specificity, positive predictive value, and false negative rate. Estimations were also compared with current data from the literature. The response rate was 29% in both groups. The reduction in the number of deaths due to screening was overestimated six-fold (95% confidence interval CI: 4-8) compared with the actual data, and there was no effect of group allocation. Providing the correct solutions to doctors had no systematic effect on their answers. Doctors poorly understand the test characteristics of lung cancer screening. Providing the correct solutions in advance did not improve the answers. Continuing education regarding lung cancer screening and the interpretation of test characteristics may be a simple remedy. Clinical trial registered with www.clinicaltrials.gov (NCT02542332).

  19. Novel simple and practical nutritional screening tool for cancer inpatients: a pilot study.

    PubMed

    Zekri, Jamal; Morganti, Julie; Rizvi, Azhar; Sadiq, Bakr Bin; Kerr, Ian; Aslam, Mohamed

    2014-05-01

    There is lack of consensus on how nutritional screening and intervention should be provided to cancer patients. Nutritional screening and support of cancer patients are not well established in the Middle East. We report our systematic and practical experience led by a qualified specialist dietician in a cancer inpatient setting, using a novel nutritional screening tool. Ninety-seven consecutive inpatients underwent nutritional screening and categorised into three nutritional risk groups based on oral intake, gastrointestinal symptoms, body mass index (BMI) and weight loss. Nutritional support was introduced accordingly. Statistical tests used included ANOVA, Bonferroni post hoc, chi-square and log rank tests. Median age was 48 (19-87)years. Patients were categorised into three nutritional risk groups: 55 % low, 37 % intermediate and 8 % high. Nutritional intervention was introduced for 36 % of these patients. Individually, weight, BMI, oral intake, serum albumin on admission and weight loss significantly affected nutritional risk and nutritional intervention (all significant P values). Eighty-seven, 60 and 55 % of patients admitted for chemotherapy, febrile neutropenia and other reasons, respectively, did not require specific nutritional intervention. There was a statistically significant relationship between nutritional risk and nutritional intervention (P=0.005). Significantly more patients were alive at 3 months in low (91 %) than intermediate (75 %) than high (37 %)-risk groups. About a third of cancer inpatients require nutritional intervention. The adopted nutritional risk assessment tool is simple and practical. The validity of this tool is supported by its significant relation with known individual nutritional risk factors. This should be confirmed in larger prospective study and comparing this new tool with other established ones.

  20. SeHCAT absorption: a simple test of ileal dysfunction.

    PubMed

    Fagan, E A; Chadwick, V S; Baird, I M

    1983-01-01

    A new selenium-labelled synthetic bile salt SeHCAT (taurine conjugate of 23-[75Se]-25-homocholic acid) was assessed as a test of ileal dysfunction in 20 patients with inflammatory bowel disease (IBD). Whole body retention of SeHCAT was compared with tests of vitamin B12 absorption (Schilling test and whole body retention) and the cholylglycine-1-14C breath test and faecal isotope excretion. Clear differentiation, with no overlap was obtained between 10 normal subjects and patients with ileal disease/resection in the SeHCAT 7-day retention results. The Schilling test was more sensitive; enabling discrimination between patients with limited and extensive ileal disease/resection. An unexpected rise in SeHCAT retention was observed in patients with colonic IBD. The 7-day SeHCAT retention is a safe, simple screening test for ileal dysfunction and has practical advantages compared with the Schilling test.

  1. Prospective phase II study evaluating the efficacy of swallow ability screening tests and pneumonia prevention using a team approach for elderly patients with gastric cancer.

    PubMed

    Miki, Yuichiro; Makuuchi, Rie; Honda, Shinsaku; Tokunaga, Masanori; Tanizawa, Yutaka; Bando, Etsuro; Kawamura, Taiichi; Yurikusa, Takashi; Tanuma, Akira; Terashima, Masanori

    2018-03-01

    Aging partly impairs swallowing function, which is considered a risk factor for postoperative pneumonia (PP). We evaluated the efficacy of a new team-based strategy to reduce the incidence of PP in elderly patients with gastric cancer. This single-center, prospective phase II study included elderly patients (≥75 years old) with gastric cancer undergoing gastric surgery. The primary endpoint was the incidence of Clavien-Dindo grade II or higher PP. Patients were initially screened using three swallowing function screening tests: a symptom questionnaire, the modified water swallow test (MSWT), and the repetitive saliva swallowing test (RSST). All patients were provided standard preoperative oral checks and care and simple neck muscle training. For patients who screened positive, a videofluorographic swallowing study was performed; if an abnormality was found, the patient was given intensive swallowing rehabilitation both pre- and postoperatively. Of 86 eligible patients enrolled, PP developed in 3 (3.5%). The 60% confidence interval of 1.8-6.3% had an upper limit below the prespecified threshold of 7.8%. Positive screening results were found for 19 patients (22.1%) on the symptom questionnaire, 3 (3.5%) on the MSWT, and 1 (1.2%) on the RSST. PP was not observed in any patients who screened positive. In conclusion, although the screening tests we adopted here were not sufficient to identify patients at high risk of aspiration pneumonia, perioperative interventions using a team approach might be effective in reducing the incidence of PP in elderly patients with gastric cancer.

  2. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    PubMed

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. EVALUATION OF MIXING ENERGY IN FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING

    EPA Science Inventory

    A U.S. Environmental Protection Agency (EPA) laboratory screening protocol for dispersant effectiveness consists of placing water, oil, and a dispersant in a flask and mixing the contents on an orbital shaker. Two flasks are being investigated, a simple Erlenmeyer (used in EPA's...

  4. [Study of the predictive value of detection tests for silent aspirations].

    PubMed

    Woisard, V; Réhault, E; Brouard, C; Fichaux-Bourin, P; Puech, M; Grand, S

    2009-01-01

    Screening for aspiration in patients with swallowing disorders is important in preventing complications. The tests used in this regard are insufficient due to silent aspiration relating to abnormal protective reflexes in many patients with swallowing problems. The aim of this study is to determine the predictive values of simple tests in screening for silent aspiration. The reference test used was videofluoroscopic examination on swallowing. In the presence of aspiration (FR+) the presence (ME+) or not (ME-) of a cough of throat clearing was noted. The tests being studied were a nasal test with isotonic saline and swallowing according to a set time. For screening for aspiration the presence of a "wet voice" was considered to be a sign of reduced protective reflexes. 1) During the nasal test, the results are 100% for the positive predictive value (VPp) and 83.3% for the negative predictive value (VPn); 2) These results are respectively 84.6% and 35.9% during the swallowing test. Regarding screening for silent aspiration, 1) during the nasal test, the results are 62.5% for the positive predictive value (VPp) and 36.3% for the negative predictive value (VPn); 2) These results are respectively 54.5% and 26.6% during the swallowing test. This preliminary study points out the lack of predictive value of the nasal test and the swallow test for the silent aspirations. However the results could be useful for other researchers developing other tests in this area.

  5. Simple exercise test score versus cardiac stress test for the prediction of coronary artery disease in patients with type 2 diabetes.

    PubMed

    Pikto-Pietkiewicz, Witold; Przewłocka, Monika; Chybowska, Barbara; Cyciwa, Alona; Pasierski, Tomasz

    2014-01-01

    Type 2 diabetes markedly increases the risk of coronary heart disease (CHD), and screening for CHD is suggested by the guidelines. The aim of the study was to compare the diagnostic usefulness of the simple exercise test score, incorporating the clinical data and cardiac stress test results, with the standard stress test in patients with type 2 diabetes. A total of 62 consecutive patients (aged 65.4 ±8.5 years; 32 men) with type 2 diabetes and clinical symptoms suggesting CHD underwent a stress test followed by coronary angiography. The simple score was calculated for all patients. Significant coronary stenosis was observed in 41 patients (66.1%). Stress test results were positive in 36 patients (58.1%). The mean simple score was high (65.5 ±14.3 points). A positive linear relationship was observed between the score and the prevalence of CHD (R2 = 0.19; P <0.001) as well as its severity (R² = 0.23; P <0.001). The area under the receiver-operating characteristic curve for the simple score was 0.74 (95% confidence interval [CI], 0.62-0.86). At the original cut-off value of 60 points, the score had a similar prognostic value to that of the standard stress test. However, in a multivariate analysis, only the simple score (odds ratio [OR], 1.46; 95% CI, 1.11-1.94; P <0.01 for an increase in the score by 1 point) and male sex (OR, 1.57; 95% CI, 1.24-1.98; P <0.001) remained independent predictors of CHD. In patients with type 2 diabetes, the simple score correlated with the prevalence and severity of CHD. However, the cut-off value of 60 points was inadequate in the population of diabetic patients with high risk of CHD. The simple score used instead of or together with the stress test was a better predictor of CHD than the stress test alone.

  6. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  7. Efficacy of human papillomavirus-based screen-and-treat for cervical cancer prevention among HIV-infected women.

    PubMed

    Kuhn, Louise; Wang, Chunhui; Tsai, Wei-Yann; Wright, Thomas C; Denny, Lynette

    2010-10-23

    Cervical cancer prevention should be provided as part of primary healthcare services for HIV-infected women but conventional screening programs are difficult to implement in low-resource settings. Here, we evaluate the efficacy among HIV-infected women of a simpler, screen-and-treat strategy in which all women with a positive screening test are treated with cryotherapy. We conducted a randomized clinical trial of two screen-and-treat strategies among 6555 women in Cape Town, South Africa, among whom 956 were HIV-positive. Women were randomized to screen-and-treat utilizing either human papillomavirus DNA testing or visual inspection with acetic acid as the screening method or to a control group. Women were followed for up to 36 months after randomization with colposcopy and biopsy to determine the study endpoint of cervical intraepithelial neoplasia grade 2 or higher. In the control group, HIV-positive women had higher rates of cervical intraepithelial neoplasia grade 2 or higher detected by 36 months (14.9%) than HIV-negative women (4.6%) (P = 0.0006). Screen-and-treat utilizing human papillomavirus DNA testing significantly reduced cervical intraepithelial neoplasia grade 2 or higher through 36 months in both HIV-positive (relative risk = 0.20, 95% confidence interval 0.06-0.69) and HIV-negative women (relative risk = 0.31, 95% confidence interval 0.20-0.50). Reductions in the visual inspection with acetic acid-and-treat group were less marked. Complications of cryotherapy were mostly minor and did not differ in frequency between HIV-positive and HIV-negative women. Screen-and-treat using human papillomavirus testing is a simple and effective method to reduce high-grade cervical cancer precursors in HIV-infected women.

  8. A Probabilistic Model for Cushing's Syndrome Screening in At-Risk Populations: A Prospective Multicenter Study.

    PubMed

    León-Justel, Antonio; Madrazo-Atutxa, Ainara; Alvarez-Rios, Ana I; Infantes-Fontán, Rocio; Garcia-Arnés, Juan A; Lillo-Muñoz, Juan A; Aulinas, Anna; Urgell-Rull, Eulàlia; Boronat, Mauro; Sánchez-de-Abajo, Ana; Fajardo-Montañana, Carmen; Ortuño-Alonso, Mario; Salinas-Vert, Isabel; Granada, Maria L; Cano, David A; Leal-Cerro, Alfonso

    2016-10-01

    Cushing's syndrome (CS) is challenging to diagnose. Increased prevalence of CS in specific patient populations has been reported, but routine screening for CS remains questionable. To decrease the diagnostic delay and improve disease outcomes, simple new screening methods for CS in at-risk populations are needed. To develop and validate a simple scoring system to predict CS based on clinical signs and an easy-to-use biochemical test. Observational, prospective, multicenter. Referral hospital. A cohort of 353 patients attending endocrinology units for outpatient visits. All patients were evaluated with late-night salivary cortisol (LNSC) and a low-dose dexamethasone suppression test for CS. Diagnosis or exclusion of CS. Twenty-six cases of CS were diagnosed in the cohort. A risk scoring system was developed by logistic regression analysis, and cutoff values were derived from a receiver operating characteristic curve. This risk score included clinical signs and symptoms (muscular atrophy, osteoporosis, and dorsocervical fat pad) and LNSC levels. The estimated area under the receiver operating characteristic curve was 0.93, with a sensitivity of 96.2% and specificity of 82.9%. We developed a risk score to predict CS in an at-risk population. This score may help to identify at-risk patients in non-endocrinological settings such as primary care, but external validation is warranted.

  9. Measurement of Visual Reaction Times Using Hand-held Mobile Devices

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.; Arsintescu, Lucia; Flynn-Evans, Erin

    2015-01-01

    Modern mobile devices provide a convenient platform for collecting research data in the field. But,because the working of these devices is often cloaked behind multiple layers of proprietary system software, it can bedifficult to assess the accuracy of the data they produce, particularly in the case of timing. We have been collecting datain a simple visual reaction time experiment, as part of a fatigue testing protocol known as the Psychomotor Vigilance Test (PVT). In this protocol, subjects run a 5-minute block consisting of a sequence of trials in which a visual stimulus appears after an unpredictable variable delay. The subject is required to tap the screen as soon as possible after the appearance of the stimulus. In order to validate the reaction times reported by our program, we had subjects perform the task while a high-speed video camera recorded both the display screen, and a side view of the finger (observed in a mirror). Simple image-processing methods were applied to determine the frames in which the stimulus appeared and disappeared, and in which the finger made and broke contact with the screen. The results demonstrate a systematic delay between the initial contact by the finger and the detection of the touch by the software, having a value of 80 +- 20 milliseconds.

  10. Development of the Grammar and Phonology Screening (GAPS) test to assess key markers of specific language and literacy difficulties in young children.

    PubMed

    Gardner, Hilary; Froud, Karen; McClelland, Alastair; van der Lely, Heather K J

    2006-01-01

    Despite a large body of evidence regarding reliable indicators of language deficits in young children, there has not been a standardized, quick screen for language impairment. The Grammar and Phonology Screening (GAPS) test was therefore designed as a short, reliable assessment of young children's language abilities. GAPS was designed to provide a quick screening test to assess whether pre- and early school entry children have the necessary grammar and pre-reading phonological skills needed for education and social development. This paper reports the theoretical background to the test, the pilot study and reliability, and the standardization. This 10-min test comprises 11 test sentences and eight test nonsense words for direct imitation and is designed to highlight significant markers of language impairment and reading difficulties. To standardize the GAPS, 668 children aged 3.4-6.6 were tested across the UK, taking into account population distribution and socio-economic status. The test was carried out by a range of health and education professionals as well as by students and carers using only simple, written instructions. GAPS is effective in detecting a range of children in need of further in-depth assessment or monitoring for language difficulties. The results concur with those from much larger epidemiological studies using lengthy testing procedures. The GAPS test (1) provides a successful screening tool; (2) is designed to be administered by professionals and non-professionals alike; and (3) facilitates identification of language impairment or at-risk factors of reading impairment in the early educational years. Thus, the test affords a first step in a process of assessment and targeted intervention to enable children to reach their potential.

  11. SW-846 Test Method 4025: Screening for Polychlorinated Dibenzodioxins and Polychlorinated Dibenzofurans (PCDD/PCDFs) by Immunoassay

    EPA Pesticide Factsheets

    a procedure for the analysis of (PCDDs/PCDFs) in soil at 500 ppt (pg/g) using a simple onestep liquid phase oxidative cleanup or, at mid to low ppt levels, using a two step coupled column cleanup (oxidation and activated carbon binding)

  12. Training Medical Students about Hazardous Drinking Using Simple Assessment Techniques

    ERIC Educational Resources Information Center

    Hidalgo, Jesús López-Torres; Pretel, Fernando Andrés; Bravo, Beatriz Navarro; Rabadan, Francisco Escobar; Serrano Selva, Juan Pedro; Latorre Postigo, Jose Miguel; Martínez, Ignacio Párraga

    2014-01-01

    Objective: To examine the ability of medical students to identify hazardous drinkers using screening tools recommended in clinical practice. Design: Observational cross-sectional study. Setting: Faculty of Medicine of Castilla-La Mancha, Spain. Method: The medical students learnt to use Alcohol Use Disorders Identification Test (AUDIT) and…

  13. Identification of Physically Underdeveloped Pupils: Activities to Improve Their Performance.

    ERIC Educational Resources Information Center

    President's Council on Physical Fitness and Sports, Washington, DC.

    Screening tests consisting of observation procedures and simple physical exercises requiring only a chinning bar, stopwatch, and record forms are suggested for identifying pupils aged ten to seventeen who are underdeveloped in strength, flexibility, agility, or cardiorespiratory endurance. Classes should be divided into pairs with one pupil acting…

  14. Single-step colony assay for screening antibody libraries.

    PubMed

    Kato, Mieko; Hanyu, Yoshiro

    2017-08-10

    We describe a method, single-step colony assay, for simple and rapid screening of single-chain Fv fragment (scFv) libraries. Colonies of Escherichia coli expressing the scFv library are formed on a hydrophilic filter that is positioned in contact with a membrane coated with an antigen. scFv expression is triggered upon treatment of colonies with an induction reagent, following which scFvs are secreted from the cells and diffused to the antigen-coated membrane. scFvs that exhibit binding affinity for the antigen are captured by the membrane-immobilized antigen. Lastly, detection of scFv binding of the antigen on the membrane allows identification of the clones on the filter that express antigen-specific scFvs. We tested this methodology by using an anti-rabbit IgG scFv, scFv(A10B), and a rat immune scFv library. Experiments conducted using scFv(A10B) revealed that this method improves scFv expression during the colony assay. By using our method to screen an immune library of 3×10 3 scFv clones, we established several clones exhibiting affinity for the antigen. Moreover, we tested 7 other antigens, including peptides, and successfully identified positive clones. We believe that this simple procedure and controlled scFv expression of the single-step colony assay could make the antibody screening both rapid and reliable and lead to successful isolation of positive clones from antibody libraries. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Down’s syndrome screening is unethical: views of today’s research ethics committees

    PubMed Central

    Reynolds, T M

    2003-01-01

    Background: Screening for Down’s syndrome forms part of routine obstetric practice. Ethical considerations relating to genetic screening form a major part of the workload of research ethics committees. This study investigated the attitudes of research ethics committee members to several conditions varying in clinical severity and prognosis, including Down’s syndrome. Methods: The members of 40 randomly chosen research ethics committees were surveyed. A simple questionnaire comprising 19 clinical scenarios based around four “clinical” conditions was designed to review conditions that were potentially embarrassing, affecting life span but not mental ability, premature death, and intellectual impairment with a risk of neonatal cardiac defects (Down’s syndrome). Screening tests with different degrees of effectiveness were described and the diagnostic test descriptions ranged from having no risk to an unaffected fetus to causing spontaneous abortion of two normal fetuses for each affected fetus identified. Replies were graded on a scale of 1 to 5. Results: Seventy seven replies were received from 28 different research ethics committees. Screening was supported for treatment of a life threatening condition (95% in favour) but screening for conditions of a slight increase in premature death (14% in favour) or cosmetic features (10% in favour) were considered unethical. Views were ambiguous (49% in favour) about conditions involving significant shortening of lifespan. Down’s syndrome screening was considered more ethical when described as a serious condition (56% in favour) than when the clinical features were described (44% in favour). Once increased rates of spontaneous abortion on confirmatory testing were added, 79% (21% in favour) and 86% (14% in favour) stated that screening was unethical (for “serious” and “clinical features” descriptions, respectively). Conclusions: Down’s syndrome screening raises ethical concerns about genetic testing in general that need to be dealt with before the introduction of any prenatal screening test. PMID:12663637

  16. Screening for cervical cancer using automated analysis of PAP-smears.

    PubMed

    Bengtsson, Ewert; Malm, Patrik

    2014-01-01

    Cervical cancer is one of the most deadly and common forms of cancer among women if no action is taken to prevent it, yet it is preventable through a simple screening test, the so-called PAP-smear. This is the most effective cancer prevention measure developed so far. But the visual examination of the smears is time consuming and expensive and there have been numerous attempts at automating the analysis ever since the test was introduced more than 60 years ago. The first commercial systems for automated analysis of the cell samples appeared around the turn of the millennium but they have had limited impact on the screening costs. In this paper we examine the key issues that need to be addressed when an automated analysis system is developed and discuss how these challenges have been met over the years. The lessons learned may be useful in the efforts to create a cost-effective screening system that could make affordable screening for cervical cancer available for all women globally, thus preventing most of the quarter million annual unnecessary deaths still caused by this disease.

  17. The population impact of screening for Down syndrome: audit of 19 326 invasive diagnostic tests in England and Wales in 2008.

    PubMed

    Morris, Joan K; Waters, Jonathan J; de Souza, E

    2012-06-01

    Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a risk of miscarriage. This study determined how many women had such tests per syndrome diagnosis. The number of tests per Down, Edwards or Patau syndrome diagnosis adjusted for maternal and gestational age at diagnosis was calculated using routine data from 18 (95%) cytogenetic laboratories in England and Wales in 2008. There were 19,326 tests that identified 1118 diagnoses of Down syndrome and 615 of Edwards and Patau syndromes. There were eight chorionic villus samplings (CVS) per syndrome diagnosis compared with 16 amniocenteses (gestational age adjusted). The lowest number of tests per diagnosis (three for CVSs and for amniocentesis) resulted from an abnormal ultrasound scan. Among pregnant women, 2.9% had an invasive diagnostic test. If a CVS and an amniocentesis increase the risk of a miscarriage by 1% and 0.5%, respectively, approximately one miscarriage for every 14 Down, Edwards or Patau syndrome diagnosis would have occurred. A simple measurement of the population impact of screening for Down syndrome can be calculated using data already collected. Annual estimates should be produced to monitor the national fetal anomaly screening programme. © 2012 John Wiley & Sons, Ltd. © 2012 John Wiley & Sons, Ltd.

  18. Smartphone-Based Hearing Screening in Noisy Environments

    PubMed Central

    Na, Youngmin; Joo, Hyo Sung; Yang, Hyejin; Kang, Soojin; Hong, Sung Hwa; Woo, Jihwan

    2014-01-01

    It is important and recommended to detect hearing loss as soon as possible. If it is found early, proper treatment may help improve hearing and reduce the negative consequences of hearing loss. In this study, we developed smartphone-based hearing screening methods that can ubiquitously test hearing. However, environmental noise generally results in the loss of ear sensitivity, which causes a hearing threshold shift (HTS). To overcome this limitation in the hearing screening location, we developed a correction algorithm to reduce the HTS effect. A built-in microphone and headphone were calibrated to provide the standard units of measure. The HTSs in the presence of either white or babble noise were systematically investigated to determine the mean HTS as a function of noise level. When the hearing screening application runs, the smartphone automatically measures the environmental noise and provides the HTS value to correct the hearing threshold. A comparison to pure tone audiometry shows that this hearing screening method in the presence of noise could closely estimate the hearing threshold. We expect that the proposed ubiquitous hearing test method could be used as a simple hearing screening tool and could alert the user if they suffer from hearing loss. PMID:24926692

  19. The cost-effectiveness of screening for hereditary hemochromatosis in Germany: a remodeling study.

    PubMed

    Rogowski, Wolf H

    2009-01-01

    Genetic tests for hereditary hemochromatosis (HH) are currently included in the German ambulatory care reimbursement scheme but only for symptomatic individuals and the offspring of HH patients. This study synthesizes the most current evidence to examine whether screening in the broader population is cost-effective and to identify the best choice of initial and follow-up screening tests. A probabilistic decision-analytic model was constructed to calculate cost per life year gained (LYG) for HH screening among male Caucasians aged 30. Three strategies were considered in both the general population and male offspring of HH patients: phenotypic (transferrin saturation, TS), genotypic (C282Y mutation), and sequential (genotype if TS is elevated) screening. The incremental cost-effectiveness of sequential screening among male offspring, sequential population-wide screening, and genotypic screening is 41000, 124000, and 161000 Eero/LYG, respectively. All other strategies were subject to simple or extended dominance. The results are subject to high uncertainty. The most influential parameters in the deterministic one-way sensitivity analysis are discounting of life years gained and the adherence of patients to preventive phlebotomy. The current German policy of only screening at-risk individuals is consistent with health economic decision making based on typically accepted thresholds. However, conducting the DNA test after the first elevated TS result is more cost-effective than waiting for a second TS result as recommended by the German guidelines. Further empirical work regarding adherence to long-term prevention recommendations and explicit and well-justified guidance for the choice of discount rates in German economic evaluation are needed.

  20. Simple assessment of olfaction in patients with chronic rhinosinusitis.

    PubMed

    Kim, Byung Guk; Oh, Jeong-Hoon; Choi, Ha Na; Park, So Young

    2015-03-01

    The brief-smell identification test (B-SIT) can substitute for the butanol threshold test (BTT) in screening of anosmia and postoperative assessment of olfactory outcomes in patients with chronic rhinosinusitis (CRS). A time-effective test battery composed of B-SIT and the visual analog scale (VAS) can be implemented for simple olfactory assessment in any otolaryngology clinic. Anosmia is a distinct clinical entity requiring special attention. Unpredictable olfactory outcomes after surgery make preoperative assessment more important. We compared the results of the BTT, B-SIT, and VAS to investigate whether B-SIT or VAS can substitute for BTT in screening of anosmia and postoperative follow-up. We collected data on 68 CRS patients who had bilateral CRS and underwent endoscopic sinus surgery. Olfactory performance was graded using the BTT: normosmia, hyposmia, or anosmia. VAS and B-SIT were also performed. All tests were repeated 6 months after surgery. Postoperative improvement was defined by an increase of the BTT score ≥ 2. The B-SIT and VAS scores of the anomics were significantly lower than those of the normosmics. B-SIT discriminated anosmia with high specificity. Within the improvement group, postoperative increase of B-SIT/VAS score showed significance. However, neither the B-SIT nor the VAS differentiated between no change and deterioration of olfaction.

  1. Effects of three pesticides on the avoidance behavior of earthworms in laboratory tests performed under temperate and tropical conditions.

    PubMed

    Garcia, Marcos; Römbke, Jörg; de Brito, Marcus Torres; Scheffczyk, Adam

    2008-05-01

    Little research has been performed on the impact of pesticides on earthworms under tropical conditions. Taking into consideration the often-limited resources in tropical countries, simple screening tests are needed. Therefore, it was investigated whether three pesticides relevant for the Brazilian Amazon (benomyl, carbendazim, lambda-cyhalothrin) affect the avoidance behavior of the earthworm Eisenia fetida. The tests were performed for two days according to ISO guideline 17512 but were adapted to tropical conditions (i.e. test substrate, test organism and temperature). The results indicate that this test gives reproducible and reliable results. Toxicity values (NOEC, EC50) are lower than those determined in 14 day-acute mortality tests and are approximately in the same range such as those found in 56 day-chronic reproduction tests with the same earthworm species, which were performed in parallel. Therefore, the use of the earthworm avoidance tests is recommended as a screening tool for the risk assessment of pesticides.

  2. The Evonik-Mainz Eye Care-Study (EMECS): Development of an Expert System for Glaucoma Risk Detection in a Working Population

    PubMed Central

    Wahl, Jochen; Barleon, Lorenz; Morfeld, Peter; Lichtmeß, Andrea; Haas-Brähler, Sibylle; Pfeiffer, Norbert

    2016-01-01

    Purpose To develop an expert system for glaucoma screening in a working population based on a human expert procedure using images of optic nerve head (ONH), visual field (frequency doubling technology, FDT) and intraocular pressure (IOP). Methods 4167 of 13037 (32%) employees between 40 and 65 years of Evonik Industries were screened. An experienced glaucoma expert (JW) assessed papilla parameters and evaluated all individual screening results. His classification into “no glaucoma”, “possible glaucoma” and “probable glaucoma” was defined as “gold standard”. A screening model was developed which was tested versus the gold-standard. This model took into account the assessment of the ONH. Values and relationships of CDR and IOP and the FDT were considered additionally and a glaucoma score was generated. The structure of the screening model was specified a priori whereas values of the parameters were chosen post-hoc to optimize sensitivity and specificity of the algorithm. Simple screening models based on IOP and / or FDT were investigated for comparison. Results 111 persons (2.66%) were classified as glaucoma suspects, thereof 13 (0.31%) as probable and 98 (2.35%) as possible glaucoma suspects by the expert. Re-evaluation by the screening model revealed a sensitivity of 83.8% and a specificity of 99.6% for all glaucoma suspects. The positive predictive value of the model was 80.2%, the negative predictive value 99.6%. Simple screening models showed insufficient diagnostic accuracy. Conclusion Adjustment of ONH and symmetry parameters with respect to excavation and IOP in an expert system produced sufficiently satisfying diagnostic accuracy. This screening model seems to be applicable in such a working population with relatively low age and low glaucoma prevalence. Different experts should validate the model in different populations. PMID:27479301

  3. The Evonik-Mainz Eye Care-Study (EMECS): Development of an Expert System for Glaucoma Risk Detection in a Working Population.

    PubMed

    Wahl, Jochen; Barleon, Lorenz; Morfeld, Peter; Lichtmeß, Andrea; Haas-Brähler, Sibylle; Pfeiffer, Norbert

    2016-01-01

    To develop an expert system for glaucoma screening in a working population based on a human expert procedure using images of optic nerve head (ONH), visual field (frequency doubling technology, FDT) and intraocular pressure (IOP). 4167 of 13037 (32%) employees between 40 and 65 years of Evonik Industries were screened. An experienced glaucoma expert (JW) assessed papilla parameters and evaluated all individual screening results. His classification into "no glaucoma", "possible glaucoma" and "probable glaucoma" was defined as "gold standard". A screening model was developed which was tested versus the gold-standard. This model took into account the assessment of the ONH. Values and relationships of CDR and IOP and the FDT were considered additionally and a glaucoma score was generated. The structure of the screening model was specified a priori whereas values of the parameters were chosen post-hoc to optimize sensitivity and specificity of the algorithm. Simple screening models based on IOP and / or FDT were investigated for comparison. 111 persons (2.66%) were classified as glaucoma suspects, thereof 13 (0.31%) as probable and 98 (2.35%) as possible glaucoma suspects by the expert. Re-evaluation by the screening model revealed a sensitivity of 83.8% and a specificity of 99.6% for all glaucoma suspects. The positive predictive value of the model was 80.2%, the negative predictive value 99.6%. Simple screening models showed insufficient diagnostic accuracy. Adjustment of ONH and symmetry parameters with respect to excavation and IOP in an expert system produced sufficiently satisfying diagnostic accuracy. This screening model seems to be applicable in such a working population with relatively low age and low glaucoma prevalence. Different experts should validate the model in different populations.

  4. Comparing perceived and test-based knowledge of cancer risk and prevention among Hispanic and African Americans: an example of community participatory research.

    PubMed

    Jones, Loretta; Bazargan, Mohsen; Lucas-Wright, Anna; Vadgama, Jaydutt V; Vargas, Roberto; Smith, James; Otoukesh, Salman; Maxwell, Annette E

    2013-01-01

    Most theoretical formulations acknowledge that knowledge and awareness of cancer screening and prevention recommendations significantly influence health behaviors. This study compares perceived knowledge of cancer prevention and screening with test-based knowledge in a community sample. We also examine demographic variables and self-reported cancer screening and prevention behaviors as correlates of both knowledge scores, and consider whether cancer related knowledge can be accurately assessed using just a few, simple questions in a short and easy-to-complete survey. We used a community-partnered participatory research approach to develop our study aims and a survey. The study sample was composed of 180 predominantly African American and Hispanic community individuals who participated in a full-day cancer prevention and screening promotion conference in South Los Angeles, California, on July 2011. Participants completed a self-administered survey in English or Spanish at the beginning of the conference. Our data indicate that perceived and test-based knowledge scores are only moderately correlated. Perceived knowledge score shows a stronger association with demographic characteristics and other cancer related variables than the test-based score. Thirteen out of twenty variables that are examined in our study showed a statistically significant correlation with the perceived knowledge score, however, only four variables demonstrated a statistically significant correlation with the test-based knowledge score. Perceived knowledge of cancer prevention and screening was assessed with fewer items than test-based knowledge. Thus, using this assessment could potentially reduce respondent burden. However, our data demonstrate that perceived and test-based knowledge are separate constructs.

  5. Comparison of immunohistochemistry and polymerase chain reaction for detection of West Nile virus in naturally infected dead birds.

    PubMed

    Sandhu, Tejbir; Sidhu, Dalbinder; Dhillon, Major; Fang, Ying

    2010-10-04

    Credible vector-borne disease surveillance programs, especially in developing countries with limited resources, must include diagnostic tests that are efficient, inexpensive and simple and safe to administer while maintaining high levels of sensitivity and specificity. Since immunohistochemistry (IHC) includes most of these features, its sensitivity, specificity, predictive positive value (PPV) and predictive negative value (PNV) for West Nile virus (WNv) screening were compared to those of the gold standard, RT-PCR testing of kidney tissue in dead birds. IHC and RT-PCR were performed for WNv antigen on 41 dead birds (belonging to five orders) collected from the northwest region of the Riverside County of California. Fixed tissue sections were screened by IHC using polyclonal antibodies, and frozen kidney tissues were tested with RT-PCR. Kidney screening with IHC showed sensitivity, specificity, PPV and NPV of 95.45%, 73.68%, 80.77% and 93.33%, respectively. Based on WNv screening of kidney tissue, IHC and RT-PCR were in agreement with 95.45% (21/22) for positive dead birds and were in 100% (22/22) agreement when multi-organ screening by IHC was performed. The present study showed that IHC is as equally effective as RT-PCR in screening for WNv in dead birds. Therefore, IHC can effectively serve as a competent screening technique for those disease surveillance agencies that lack expensive RT-PCR technology while promoting safer biohazardous conditions, except at the initial stage of tissue collection.

  6. A simple biota removal algorithm for 35 GHz cloud radar measurements

    NASA Astrophysics Data System (ADS)

    Kalapureddy, Madhu Chandra R.; Sukanya, Patra; Das, Subrata K.; Deshpande, Sachin M.; Pandithurai, Govindan; Pazamany, Andrew L.; Ambuj K., Jha; Chakravarty, Kaustav; Kalekar, Prasad; Krishna Devisetty, Hari; Annam, Sreenivas

    2018-03-01

    Cloud radar reflectivity profiles can be an important measurement for the investigation of cloud vertical structure (CVS). However, extracting intended meteorological cloud content from the measurement often demands an effective technique or algorithm that can reduce error and observational uncertainties in the recorded data. In this work, a technique is proposed to identify and separate cloud and non-hydrometeor echoes using the radar Doppler spectral moments profile measurements. The point and volume target-based theoretical radar sensitivity curves are used for removing the receiver noise floor and identified radar echoes are scrutinized according to the signal decorrelation period. Here, it is hypothesized that cloud echoes are observed to be temporally more coherent and homogenous and have a longer correlation period than biota. That can be checked statistically using ˜ 4 s sliding mean and standard deviation value of reflectivity profiles. The above step helps in screen out clouds critically by filtering out the biota. The final important step strives for the retrieval of cloud height. The proposed algorithm potentially identifies cloud height solely through the systematic characterization of Z variability using the local atmospheric vertical structure knowledge besides to the theoretical, statistical and echo tracing tools. Thus, characterization of high-resolution cloud radar reflectivity profile measurements has been done with the theoretical echo sensitivity curves and observed echo statistics for the true cloud height tracking (TEST). TEST showed superior performance in screening out clouds and filtering out isolated insects. TEST constrained with polarimetric measurements was found to be more promising under high-density biota whereas TEST combined with linear depolarization ratio and spectral width perform potentially to filter out biota within the highly turbulent shallow cumulus clouds in the convective boundary layer (CBL). This TEST technique is promisingly simple in realization but powerful in performance due to the flexibility in constraining, identifying and filtering out the biota and screening out the true cloud content, especially the CBL clouds. Therefore, the TEST algorithm is superior for screening out the low-level clouds that are strongly linked to the rainmaking mechanism associated with the Indian Summer Monsoon region's CVS.

  7. Screening for subclinical Cushing's syndrome in type 2 diabetes mellitus: low false-positive rates with nocturnal salivary cortisol.

    PubMed

    Gagliardi, L; Chapman, I M; O'Loughlin, P; Torpy, D J

    2010-04-01

    The diagnosis of subclinical Cushing's syndrome (SCS) is important, but its relative rarity amongst patients with common metabolic disorders requires a simple test with a low false-positive rate. Using nocturnal salivary cortisol (NSC), which we first validated in patients with suspected and proven Cushing's syndrome, we screened 106 overweight patients with type 2 diabetes mellitus, a group at high risk of SCS and nontumoral hypothalamic-pituitary-adrenal axis perturbations. Our hypothesis was that a lower false-positive rate with NSC was likely, compared with that reported with the dexamethasone suppression test (DST) (10-20%), currently the foundation of diagnosis of SCS. No participant had clinically apparent Cushing's syndrome. Three participants had an elevated NSC but further testing excluded SCS. In this study, NSC had a lower false-positive rate (3%) than previously reported for the DST. Given the reported excellent performance of NSC in detection of hypercortisolism, the low false-positive rate in SCS suggests NSC may be superior to the DST for SCS screening. The NSC and DST should be compared directly in metabolic disorder patients; although our data suggest the patient group will need to be substantially larger to definitively determine the optimal screening test. Georg Thieme Verlag KG Stuttgart New York.

  8. [Evaluation of fetal lung maturity using a modified lecithin-sphingomyelin determination and Clements' foam test].

    PubMed

    Neumann, G; Gartzke, J; Faber, G

    1978-01-01

    The modified thin layer chromatographic method for the determination of the phospholipids lecithin and sphingomyelin from amniotic fluid is useful in estimating fetal pulmonary maturity. The foam test of Clements is a simple rapid method for screening of suspicious cases of pregnancies at risk and of great value as bed side test even performing by the doctor. In comparing Clements-Test with thin layer chromatographic for L/S-Ratio determination we found a good correlation of 81,8% of all cases.

  9. 'Nano-immuno test' for the detection of live Mycobacterium avium subspecies paratuberculosis bacilli in the milk samples using magnetic nano-particles and chromogen.

    PubMed

    Singh, Manju; Singh, Shoor Vir; Gupta, Saurabh; Chaubey, Kundan Kumar; Stephan, Bjorn John; Sohal, Jagdip Singh; Dutta, Manali

    2018-04-26

    Early rapid detection of Mycobacterium avium subspecies paratuberculosis (MAP) bacilli in milk samples is the major challenge since traditional culture method is time consuming and laboratory dependent. We report a simple, sensitive and specific nano-technology based 'Nano-immuno test' capable of detecting viable MAP bacilli in the milk samples within 10 h. Viable MAP bacilli were captured by MAP specific antibody-conjugated magnetic nano-particles using resazurin dye as chromogen. Test was optimized using true culture positive (10-bovine and 12-goats) and true culture negative (16-bovine and 25-goats) raw milk samples. Domestic livestock species in India are endemically infected with MAP. After successful optimization, sensitivity and specificity of the 'nano-immuno test' in goats with respect to milk culture was 91.7% and 96.0%, respectively. Whereas, it was 90.0% (sensitivity) and 92.6% (specificity) with respect to IS900 PCR. In bovine milk samples, sensitivity and specificity of 'nano-immuno test' with respect to milk culture was 90.0% and 93.7%, respectively. However, with respect to IS900 PCR, the sensitivity and specificity was 88.9% and 94.1%, respectively. Test was validated with field raw milk samples (goats-258 and bovine-138) collected from domestic livestock species to detect live/viable MAP bacilli. Of 138 bovine raw milk samples screened by six diagnostic tests, 81 (58.7%) milk samples were positive for MAP infection in one or more than one diagnostic tests. Of 81 (58.7%) positive bovine raw milk samples, only 24 (17.4%) samples were detected positive for the presence of viable MAP bacilli. Of 258 goats raw milk samples screened by six diagnostic tests, 141 (54.6%) were positive for MAP infection in one or more than one test. Of 141 (54.6%) positive raw milk samples from goats, only 48 (34.0%) were detected positive for live MAP bacilli. Simplicity and efficiency of this novel 'nano-immuno test' makes it suitable for wide-scale screening of milk samples in the field. Standardization, validation and re-usability of functionalized nano-particles and the test was successfully achieved in field samples. Test was highly specific, simple to perform and easy to read by naked eyes and does not require laboratory support in the performance of test. Test has potential to be used as screening test to estimate bio-load of MAP in milk samples at National level.

  10. Comparison of Refractory Performance in Black Liquor Gasifiers and a Smelt Test System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peascoe, RA

    2001-09-25

    Prior laboratory corrosion studies along with experience at the black liquor gasifier in New Bern, North Carolina, clearly demonstrate that serious material problems exist with the gasifier's refractory lining. Mullite-based and alumina-based refractories used at the New Bern facility suffered significant degradation even though they reportedly performed adequately in smaller scale systems. Oak Ridge National Laboratory's involvement in the failure analysis, and the initial exploration of suitable replacement materials, led to the realization that a simple and reliable, complementary method for refractory screening was needed. The development of a laboratory test system and its suitability for simulating the environment ofmore » black liquor gasifiers was undertaken. Identification and characterization of corrosion products were used to evaluate the test system as a rapid screening tool for refractory performance and as a predictor of refractory lifetime. Results from the test systems and pl ants were qualitatively similar.« less

  11. Clinical history for diagnosis of dementia in men: Caerphilly Prospective Study

    PubMed Central

    Creavin, Sam; Fish, Mark; Gallacher, John; Bayer, Antony; Ben-Shlomo, Yoav

    2015-01-01

    Background Diagnosis of dementia often requires specialist referral and detailed, time-consuming assessments. Aim To investigate the utility of simple clinical items that non-specialist clinicians could use, in addition to routine practice, to diagnose all-cause dementia syndrome. Design and setting Cross-sectional diagnostic test accuracy study. Participants were identified from the electoral roll and general practice lists in Caerphilly and adjoining villages in South Wales, UK. Method Participants (1225 men aged 45–59 years) were screened for cognitive impairment using the Cambridge Cognitive Examination, CAMCOG, at phase 5 of the Caerphilly Prospective Study (CaPS). Index tests were a standardised clinical evaluation, neurological examination, and individual items on the Informant Questionnaire for Cognitive Disorders in the Elderly (IQCODE). Results Two-hundred and five men who screened positive (68%) and 45 (4.8%) who screened negative were seen, with 59 diagnosed with dementia. The model comprising problems with personal finance and planning had an area under the curve (AUC) of 0.92 (95% confidence interval [CI] = 0.86 to 0.97), positive likelihood ratio (LR+) of 23.7 (95% CI = 5.88 to 95.6), negative likelihood ratio (LR−) of 0.41 (95% CI = 0.27 to 0.62). The best single item for ruling out was no problems learning to use new gadgets (LR− of 0.22, 95% CI = 0.11 to 0.43). Conclusion This study found that three simple questions have high utility for diagnosing dementia in men who are cognitively screened. If confirmed, this could lead to less burdensome assessment where clinical assessment suggests possible dementia. PMID:26212844

  12. Young Children and Turtle Graphics Programming: Generating and Debugging Simple Turtle Programs.

    ERIC Educational Resources Information Center

    Cuneo, Diane O.

    Turtle graphics is a popular vehicle for introducing children to computer programming. Children combine simple graphic commands to get a display screen cursor (called a turtle) to draw designs on the screen. The purpose of this study was to examine young children's abilities to function in a simple computer programming environment. Four- and…

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewani, Aliya A., E-mail: a.ashraf@griffith.edu.au; O’Keefe, Steven G.; Thiel, David V.

    A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substratemore » thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.« less

  14. Optically transparent frequency selective surfaces on flexible thin plastic substrates

    NASA Astrophysics Data System (ADS)

    Dewani, Aliya A.; O'Keefe, Steven G.; Thiel, David V.; Galehdar, Amir

    2015-02-01

    A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substrate thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.

  15. Correction of Refractive Errors in Rhesus Macaques (Macaca mulatta) Involved in Visual Research

    PubMed Central

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-01-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals. PMID:25427343

  16. Correction of refractive errors in rhesus macaques (Macaca mulatta) involved in visual research.

    PubMed

    Mitchell, Jude F; Boisvert, Chantal J; Reuter, Jon D; Reynolds, John H; Leblanc, Mathias

    2014-08-01

    Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals.

  17. Virtual daily living test to screen for mild cognitive impairment using kinematic movement analysis

    PubMed Central

    Seo, Kyoungwon; Kim, Jae-kwan; Oh, Dong Hoon

    2017-01-01

    Questionnaires or computer-based tests for assessing activities of daily living are well-known approaches to screen for mild cognitive impairment (MCI). However, questionnaires are subjective and computerized tests only collect simple performance data with conventional input devices such as a mouse and keyboard. This study explored the validity and discriminative power of a virtual daily living test as a new diagnostic approach to assess MCI. Twenty-two healthy controls and 20 patients with MCI were recruited. The virtual daily living test presents two complex daily living tasks in an immersive virtual reality environment. The tasks were conducted based on subject body movements and detailed behavioral data (i.e., kinematic measures) were collected. Performance in both the proposed virtual daily living test and conventional neuropsychological tests for patients with MCI was compared to healthy controls. Kinematic measures considered in this study, such as body movement trajectory, time to completion, and speed, classified patients with MCI from healthy controls, F(8, 33) = 5.648, p < 0.001, η2 = 0.578. When both hand and head speed were employed in conjunction with the immediate free-recall test, a conventional neuropsychological test, the discrimination power for screening MCI was significantly improved to 90% sensitivity and 95.5% specificity (cf. the immediate free-recall test alone has 80% sensitivity and 77.3% specificity). Inclusion of the kinematic measures in screening for MCI significantly improved the classification of patients with MCI compared to the healthy control group, Wilks’ Lambda = 0.451, p < 0.001. PMID:28738088

  18. [Express diagnostics of bovine leucosis by immune sensor based on surface plasmon resonance].

    PubMed

    Pyrohova, L V; Starodub, M F; Artiukh, V P; Nahaieva, L I; Dobrosol, H I

    2002-01-01

    An immune sensor based on the surface plasmon resonance (SPR) was developed for express diagnostics of bovine leucosis. The sensor was used for detection of the level of antibodies against bovine leukaemia virus (BLV) in the blood serum. The industrially manufactured BLV antigen for screening test in the agar gel immunodiffusion (AGID) required the additional purification in order to be used in immune sensor analysis. It was shown that immune sensor analysis was more sensitive, rapid and simple in comparison with the traditional AGID test. It was stated that the developed immune sensor was capable to be used for performance of bovine leucosis screening at the farms and the minimal dilution of the serum should be 1:500.

  19. FAITH – Fast Assembly Inhibitor Test for HIV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadravová, Romana; Rumlová, Michaela, E-mail: michaela.rumlova@vscht.cz; Department of Biotechnology, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague

    Due to the high number of drug-resistant HIV-1 mutants generated by highly active antiretroviral therapy (HAART), there is continuing demand for new types of inhibitors. Both the assembly of the Gag polyprotein into immature and mature HIV-1 particles are attractive candidates for the blocking of the retroviral life cycle. Currently, no therapeutically-used assembly inhibitor is available. One possible explanation is the lack of a reliable and simple assembly inhibitor screening method. To identify compounds potentially inhibiting the formation of both types of HIV-1 particles, we developed a new fluorescent high-throughput screening assay. This assay is based on the quantification ofmore » the assembly efficiency in vitro in a 96-well plate format. The key components of the assay are HIV-1 Gag-derived proteins and a dual-labelled oligonucleotide, which emits fluorescence only when the assembly of retroviral particles is inhibited. The method was validated using three (CAI, BM2, PF74) reported assembly inhibitors. - Highlights: • Allows screening of assembly inhibitors of both mature and immature HIV-1 particles. • Based on Gag-derived proteins with CA in mature or immature conformation. • Simple and sensitive method suitable for high-throughput screening of inhibitors. • Unlike in other HIV assembly methods, works under physiological conditions. • No washing steps are necessary.« less

  20. Quantifying the advantages and disadvantages of pre-placement genetic screening

    PubMed Central

    Palmer, K; Poole, J; Rawbone, R; Coggon, D

    2004-01-01

    Background: Tests of genotype may enable workers at unusual risk of future ill-health to be identified. Using them to select for employment, however, entails gains and losses to employers and employees. Ensuring a fair balance between the rights and obligations of each group requires a value judgement, but the advantages and disadvantages to interested parties must first be quantified in a meaningful way. Method and Results: The purposes of pre-employment screening are reviewed, and several simple measures relevant to the separate interests of employers and job applicants proposed—number screened to prevent a single adverse outcome; number excluded to prevent a case; expected incidence of the adverse outcome in those excluded; and preventable fraction. The derivation of these measures is illustrated, and the factors that influence them (the prevalence of the prognostic trait, the relative risk that it carries for an adverse outcome, and the overall incidence of disease) are related algebraically and graphically, to aid judgement on the utility of screening under different circumstances. Conclusions: In sensitive areas such as genetic testing the onus should be on the employer to justify plans for pre-placement screening. Several quantitative measures can be used to inform the ethical and economic debate about screening and to evaluate alternative strategies for prevention. PMID:15090667

  1. Quantifying the advantages and disadvantages of pre-placement genetic screening.

    PubMed

    Palmer, K T; Poole, J; Rawbone, R G; Coggon, D

    2004-05-01

    Tests of genotype may enable workers at unusual risk of future ill-health to be identified. Using them to select for employment, however, entails gains and losses to employers and employees. Ensuring a fair balance between the rights and obligations of each group requires a value judgement, but the advantages and disadvantages to interested parties must first be quantified in a meaningful way. The purposes of pre-employment screening are reviewed, and several simple measures relevant to the separate interests of employers and job applicants proposed-number screened to prevent a single adverse outcome; number excluded to prevent a case; expected incidence of the adverse outcome in those excluded; and preventable fraction. The derivation of these measures is illustrated, and the factors that influence them (the prevalence of the prognostic trait, the relative risk that it carries for an adverse outcome, and the overall incidence of disease) are related algebraically and graphically, to aid judgement on the utility of screening under different circumstances. In sensitive areas such as genetic testing the onus should be on the employer to justify plans for pre-placement screening. Several quantitative measures can be used to inform the ethical and economic debate about screening and to evaluate alternative strategies for prevention.

  2. Detection of Salmonella enterica serovar Enteritidis (SE) Antibodies in Serum Using A Polystyrene Bead/SE Flagella Agglutination Assay

    USDA-ARS?s Scientific Manuscript database

    Serologic screening of flocks can be an important method to detect Salmonella enteritidis (SE) infections but can be labor intensive or lack specificity. Our goal was to develop a rapid agglutination assay using SE flagella adsorbed to polystyrene beads as a simple, relatively specific test to dete...

  3. Cognitive Representations of Obligation and Prohibition Signs when They Provide the Same Amount of Semantic Information

    ERIC Educational Resources Information Center

    Castro, C.; Moreno-Rios, S.; Tornay, F. J.

    2012-01-01

    The aim of this research was to test whether there is an inherent difficulty in understanding prohibition signs rather than obligation signs. In the experiment conducted, participants decided whether simple car movements presented on a computer screen were allowed or not according to either obligation or prohibition traffic signs. The information…

  4. Current and future molecular diagnostics in colorectal cancer and colorectal adenoma.

    PubMed

    Tsang, Andy Hin-Fung; Cheng, Ka-Ho; Wong, Apple Siu-Ping; Ng, Simon Siu-Man; Ma, Brigette Buig-Yue; Chan, Charles Ming-Lok; Tsui, Nancy Bo-Yin; Chan, Lawrence Wing-Chi; Yung, Benjamin Yat-Ming; Wong, Sze-Chuen Cesar

    2014-04-14

    Colorectal cancer (CRC) is one of the most prevalent cancers in developed countries. On the other hand, CRC is also one of the most curable cancers if it is detected in early stages through regular colonoscopy or sigmoidoscopy. Since CRC develops slowly from precancerous lesions, early detection can reduce both the incidence and mortality of the disease. Fecal occult blood test is a widely used non-invasive screening tool for CRC. Although fecal occult blood test is simple and cost-effective in screening CRC, there is room for improvement in terms of the accuracy of the test. Genetic dysregulations have been found to play an important role in CRC development. With better understanding of the molecular basis of CRC, there is a growing expectation on the development of diagnostic tests based on more sensitive and specific molecular markers and those tests may provide a breakthrough to the limitations of current screening tests for CRC. In this review, the molecular basis of CRC development, the characteristics and applications of different non-invasive molecular biomarkers, as well as the technologies available for the detection were discussed. This review intended to provide a summary on the current and future molecular diagnostics in CRC and its pre-malignant state, colorectal adenoma.

  5. Current and future molecular diagnostics in colorectal cancer and colorectal adenoma

    PubMed Central

    Tsang, Andy Hin-Fung; Cheng, Ka-Ho; Wong, Apple Siu-Ping; Ng, Simon Siu-Man; Ma, Brigette Buig-Yue; Chan, Charles Ming-Lok; Tsui, Nancy Bo-Yin; Chan, Lawrence Wing-Chi; Yung, Benjamin Yat-Ming; Wong, Sze-Chuen Cesar

    2014-01-01

    Colorectal cancer (CRC) is one of the most prevalent cancers in developed countries. On the other hand, CRC is also one of the most curable cancers if it is detected in early stages through regular colonoscopy or sigmoidoscopy. Since CRC develops slowly from precancerous lesions, early detection can reduce both the incidence and mortality of the disease. Fecal occult blood test is a widely used non-invasive screening tool for CRC. Although fecal occult blood test is simple and cost-effective in screening CRC, there is room for improvement in terms of the accuracy of the test. Genetic dysregulations have been found to play an important role in CRC development. With better understanding of the molecular basis of CRC, there is a growing expectation on the development of diagnostic tests based on more sensitive and specific molecular markers and those tests may provide a breakthrough to the limitations of current screening tests for CRC. In this review, the molecular basis of CRC development, the characteristics and applications of different non-invasive molecular biomarkers, as well as the technologies available for the detection were discussed. This review intended to provide a summary on the current and future molecular diagnostics in CRC and its pre-malignant state, colorectal adenoma. PMID:24744577

  6. A preoperative cotininury test for abdominoplasty reduces peri-operative complications.

    PubMed

    Delaunay, F; Coquerel-Beghin, D; Magalon, G; Cohen, S R; Casanova, D; Niddam, J; Milliez, P-Y; Peillon, C; Delpierre, V; Auquit-Auckbur, I

    2018-05-16

    Smoking induces complications in plastic surgery, in particular wound healing delays. Despite a 4-weeks' abstinence asking before and after surgery, some patients denied or hid their consumption. The aim of this study was to evaluate the effectiveness of a cotininury detection test in terms of improvement in outcomes after an abdominoplasty. This retrospective cohort study included patients who underwent an abdominoplasty with umbilical transposition and lipoaspiration. Current smokers were asked to stop smoking 4 weeks before and after surgery. After 2013, we performed a preoperative cotininury test for patients having abdominoplasty, with a cancellation of surgery in case of positive result. We analyzed the test's effectiveness on delayed healing and on other complications. Two hundred and thirty-five patients were included; 80 were tested and 21,3% had a positive test. There was significantly less delayed healing in the "screening" group than in the "no screening": 20,3% versus 41,5% (P=0,002). Alike, complications were significantly less frequent in the "screening" group than in the "no screening": 18,1% versus 42,3% (P<0,001). The routine use of the cotininury test in preoperative abdominoplasties significantly reduces risk of delayed healing and other serious complications. It is an objective test, which is simple, quick and non-invasive. Smoking cessation must be at least 4 weeks before and after the surgery. Following medical advice to cease smoking by the surgeon and anesthetist, referral to an appropriate tobacco-addiction specialist clinic may be helpful for the patient who has difficulty stopping smoking. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  7. A novel metric that quantifies risk stratification for evaluating diagnostic tests: The example of evaluating cervical-cancer screening tests across populations.

    PubMed

    Katki, Hormuzd A; Schiffman, Mark

    2018-05-01

    Our work involves assessing whether new biomarkers might be useful for cervical-cancer screening across populations with different disease prevalences and biomarker distributions. When comparing across populations, we show that standard diagnostic accuracy statistics (predictive values, risk-differences, Youden's index and Area Under the Curve (AUC)) can easily be misinterpreted. We introduce an intuitively simple statistic for a 2 × 2 table, Mean Risk Stratification (MRS): the average change in risk (pre-test vs. post-test) revealed for tested individuals. High MRS implies better risk separation achieved by testing. MRS has 3 key advantages for comparing test performance across populations with different disease prevalences and biomarker distributions. First, MRS demonstrates that conventional predictive values and the risk-difference do not measure risk-stratification because they do not account for test-positivity rates. Second, Youden's index and AUC measure only multiplicative relative gains in risk-stratification: AUC = 0.6 achieves only 20% of maximum risk-stratification (AUC = 0.9 achieves 80%). Third, large relative gains in risk-stratification might not imply large absolute gains if disease is rare, demonstrating a "high-bar" to justify population-based screening for rare diseases such as cancer. We illustrate MRS by our experience comparing the performance of cervical-cancer screening tests in China vs. the USA. The test with the worst AUC = 0.72 in China (visual inspection with acetic acid) provides twice the risk-stratification (i.e. MRS) of the test with best AUC = 0.83 in the USA (human papillomavirus and Pap cotesting) because China has three times more cervical precancer/cancer. MRS could be routinely calculated to better understand the clinical/public-health implications of standard diagnostic accuracy statistics. Published by Elsevier Inc.

  8. The CERAD Neuropsychological Battery in Patients with Frontotemporal Lobar Degeneration

    PubMed Central

    Haanpää, Ramona M.; Suhonen, Noora-Maria; Hartikainen, Päivi; Koivisto, Anne M.; Moilanen, Virpi; Herukka, Sanna-Kaisa; Hänninen, Tuomo; Remes, Anne M.

    2015-01-01

    Background/Aims The diagnosis of frontotemporal lobar degeneration (FTLD) is based on neuropsychological examination in addition to clinical symptoms and brain imaging. There is no simple, validated, cognitive tool available in screening for FTLD. The Consortium to Establish a Registry for Alzheimer's Disease neuropsychological battery (CERAD-NB) was originally devised to identify the early cognitive changes related to Alzheimer's disease (AD). Our aim was to investigate the utility of the CERAD-NB in FTLD. Methods Patients with FTLD (n = 95) and AD (n = 90) were assessed with the CERAD-NB, Trail Making Test parts A and B and single-letter Phonemic Fluency. Results FTLD patients were more severely impaired in the Verbal Fluency subtest in the CERAD-NB and Trail Making Test part A compared to AD patients. In addition, AD patients were more impaired in memory subtests compared to FTLD patients. Conclusion The CERAD-NB may be a useful tool in screening for FTLD. Impaired performance in Verbal Fluency with moderately well-preserved Delayed Recall and Memory Tests may help in identifying patients with probable FTLD and discriminating FTLD from AD. Adding the Trail Making Test to the battery might enhance its value as a screening instrument for FTLD. PMID:25999981

  9. Cardiovascular and metabolic risks in psoriasis and psoriatic arthritis: pragmatic clinical management based on available evidence.

    PubMed

    Johnsson, Hanna; McInnes, Iain B; Sattar, Naveed

    2012-04-01

    Several studies suggest that patients with psoriasis and, in particular, psoriatic arthritis (PsA) are at increased risk of cardiovascular disease. These patients are also more likely to be obese and to have diabetes and fatty liver disease. This article discusses the association between psoriasis and PsA and cardiometabolic disorders, emphasising the need for better consideration of simple lifestyle interventions. It also highlights areas for future research and proposes a simple and pragmatic test portfolio to screen for cardiovascular risk and metabolic disorders in patients at higher risk.

  10. Direct urine polymerase chain reaction for chlamydia and gonorrhoea: a simple means of bringing high-throughput rapid testing to remote settings?

    PubMed

    Rahimi, Frashta; Goire, Namraj; Guy, Rebecca; Kaldor, John M; Ward, James; Nissen, Michael D; Sloots, Theo P; Whiley, David M

    2013-08-01

    Background Rapid point-of-care tests (POCTs) for chlamydia (Chlamydia trachomatis) and gonorrhoea (Neisseria gonorrhoeae) have the potential to confer health benefits in certain populations even at moderate sensitivities; however, suitable POCTs for these organisms are currently lacking. In this study, we investigated the use of direct urine polymerase chain reaction (PCR), with the view of implementing a simplified PCR strategy for high-throughput chlamydia and gonorrhoea screening in remote settings. Briefly, a simple dilution of the urine was performed before adding it directly to a real-time PCR reaction. The method was evaluated using 134 stored urine specimens that had been submitted for chlamydia and gonorrhoea testing and had been tested using a commercial C. trachomatis and N. gonorrhoeae PCR method. These included samples that were PCR-positive for chlamydia (n=87), gonorrhoea (n=16) or both (n=2). Direct urine testing was conducted using previously described in-house real-time PCR methods for C. trachomatis and N. gonorrhoeae as well as for recognised N.gonorrhoeae antimicrobial resistance mechanisms. The overall sensitivities and specificities of the direct urine PCR were 78% and 100% for chlamydia, and 83% and 100% for gonorrhoea. N.gonorrhoeae penicillin and quinolone resistance mechanisms were characterised in 14 of the 18 N. gonorrhoeae-positive samples. The results of this study show that the simplified PCR strategy may be a feasible approach for rapid screening and improving chlamydia and gonorrhoea treatment in remote settings.

  11. Performance of alternative strategies for primary cervical cancer screening in sub-Saharan Africa: systematic review and meta-analysis of diagnostic test accuracy studies

    PubMed Central

    Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick

    2015-01-01

    Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020

  12. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    PubMed

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  13. Affinity chromatography for purification of the modular protein growth factor receptor-bound protein 2 and development of a screening test for growth factor receptor-bound protein 2 Src homology 3 domain inhibitor using peroxidase-linked ligand.

    PubMed

    Gril, B; Liu, W Q; Lenoir, C; Garbay, C; Vidal, M

    2006-04-01

    Growth factor receptor-bound protein 2 (Grb2) is an adapter protein involved in the Ras-dependent signaling pathway that plays an important role in human cancers initiated by oncogenic receptors. Grb2 is constituted by one Src homology 2 domain surrounded by two SH3 domains, and the inhibition of the interactions produced by these domains could provide an antitumor approach. In evaluating chemical libraries, to search for potential Grb2 inhibitors, it was necessary to elaborate a rapid test for their screening. We have developed, first, a batch method based on the use of an affinity column bearing a Grb2-SH3 peptide ligand to isolate highly purified Grb2. We subsequently describe a very rapid 96-well screening of inhibitors based on a simple competition between purified Grb2 and a peroxidase-coupled proline-rich peptide.

  14. Quantification of Sesquiterpene Lactones in Asteraceae Plant Extracts: Evaluation of their Allergenic Potential

    PubMed Central

    Salapovic, Helena; Geier, Johannes; Reznicek, Gottfried

    2013-01-01

    Sesquiterpene lactones (SLs), mainly those with an activated exocyclic methylene group, are important allergens in Asteraceae (Compositae) plants. As a screening tool, the Compositae mix, consisting of five Asteraceae plant extracts with allergenic potential (feverfew, tansy, arnica, yarrow, and German chamomile) is part of several national patch test baseline series. However, the SL content of the Compositae mix may vary due to the source material. Therefore, a simple spectrophotometric method for the quantitative measurement of SLs with the α-methylene-γ-butyrolactone moiety was developed, giving the percentage of allergenic compounds in plant extracts. The method has been validated and five Asteraceae extracts, namely feverfew (Tanacetum parthenium L.), tansy (Tanacetum vulgare L.), arnica (Arnica montana L.), yarrow (Achillea millefolium L.), and German chamomile (Chamomilla recutita L. Rauschert) that have been used in routine patch test screening were evaluated. A good correlation could be found between the results obtained using the proposed spectrophotometric method and the corresponding clinical results. Thus, the introduced method is a valuable tool for evaluating the allergenic potential and for the simple and efficient quality control of plant extracts with allergenic potential. PMID:24106675

  15. Urinary Glucose Screening for Early Detection of Asymptomatic Type 2 Diabetes in Jeonbuk Province Korean Schoolchildren.

    PubMed

    Kim, Min Sun; Lee, Dae Yeol

    2017-06-01

    This study aimed to investigate the prevalence of glucosuria and the characteristics of diabetes in schoolchildren as detected by a school urine glucose screening program implemented from 2010 to 2013 in the Jeonbuk province area of Korea. A total of 110 children without known diabetes were analyzed. They were checked with an oral glucose tolerance test (OGTT) with other laboratory tests and their clinical data were collected. A total of 707,238 schoolchildren from a school population of 1,064,999 were screened for glucosuria. In total, over a 4-year period, 545 schoolchildren (0.077%) were positive for glucosuria on the second urine test. The prevalence of glucosuria was more common among middle and high schoolchildren than among elementary schoolchildren. Among 110 students who completed the OGTT to confirm diabetes, 40 were diagnosed with diabetes mellitus (DM); 39 children, type 2 diabetes mellitus (T2DM) and 1 child, slowly progressive insulin dependent diabetes mellitus (SPIDDM). The mean annual incidence of diabetes was 5.6 per 100,000 schoolchildren and adolescents. The subjects with diabetes diagnosed through the urine screening test showed minimal or no symptoms of diabetes. The students with diabetes were more likely to be woman and obese, and they have a higher body mass index, higher cholesterol, triglyceride, insulin, C-peptide, and fasting glucosuria values than the students with normal glucose tolerance. We identified 40 new cases of diabetes in the Korean schoolchildren with asymptomatic glucosuria on urine glucose screening. This finding shows that school urine glucose screening is a feasible and simple method for early detection of asymptomatic T2DM. © 2017 The Korean Academy of Medical Sciences.

  16. Urinary Glucose Screening for Early Detection of Asymptomatic Type 2 Diabetes in Jeonbuk Province Korean Schoolchildren

    PubMed Central

    2017-01-01

    This study aimed to investigate the prevalence of glucosuria and the characteristics of diabetes in schoolchildren as detected by a school urine glucose screening program implemented from 2010 to 2013 in the Jeonbuk province area of Korea. A total of 110 children without known diabetes were analyzed. They were checked with an oral glucose tolerance test (OGTT) with other laboratory tests and their clinical data were collected. A total of 707,238 schoolchildren from a school population of 1,064,999 were screened for glucosuria. In total, over a 4-year period, 545 schoolchildren (0.077%) were positive for glucosuria on the second urine test. The prevalence of glucosuria was more common among middle and high schoolchildren than among elementary schoolchildren. Among 110 students who completed the OGTT to confirm diabetes, 40 were diagnosed with diabetes mellitus (DM); 39 children, type 2 diabetes mellitus (T2DM) and 1 child, slowly progressive insulin dependent diabetes mellitus (SPIDDM). The mean annual incidence of diabetes was 5.6 per 100,000 schoolchildren and adolescents. The subjects with diabetes diagnosed through the urine screening test showed minimal or no symptoms of diabetes. The students with diabetes were more likely to be woman and obese, and they have a higher body mass index, higher cholesterol, triglyceride, insulin, C-peptide, and fasting glucosuria values than the students with normal glucose tolerance. We identified 40 new cases of diabetes in the Korean schoolchildren with asymptomatic glucosuria on urine glucose screening. This finding shows that school urine glucose screening is a feasible and simple method for early detection of asymptomatic T2DM. PMID:28480657

  17. Fabricating Simple Wax Screen-Printing Paper-Based Analytical Devices to Demonstrate the Concept of Limiting Reagent in Acid- Base Reactions

    ERIC Educational Resources Information Center

    Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe

    2018-01-01

    In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…

  18. The shape dependence of chameleon screening

    NASA Astrophysics Data System (ADS)

    Burrage, Clare; Copeland, Edmund J.; Moss, Adam; Stevenson, James A.

    2018-01-01

    Chameleon scalar fields can screen their associated fifth forces from detection by changing their mass with the local density. These models are an archetypal example of a screening mechanism, and have become an important target for both cosmological surveys and terrestrial experiments. In particular there has been much recent interest in searching for chameleon fifth forces in the laboratory. It is known that the chameleon force is less screened around non-spherical sources, but only the field profiles around a few simple shapes are known analytically. In this work we introduce a numerical code that solves for the chameleon field around arbitrary shapes with azimuthal symmetry placed in a spherical vacuum chamber. We find that deviations from spherical symmetry can increase the chameleon acceleration experienced by a test particle, and that the least screened objects are those which minimize some internal dimension. For the shapes considered in this work, keeping the mass, density and background environment fixed, the accelerations due to the source varied by a factor of ~ 3.

  19. Determinants of participation in prostate cancer screening: A simple analytical framework to account for healthy-user bias

    PubMed Central

    Tabuchi, Takahiro; Nakayama, Tomio; Fukushima, Wakaba; Matsunaga, Ichiro; Ohfuji, Satoko; Kondo, Kyoko; Kawano, Eiji; Fukuhara, Hiroyuki; Ito, Yuri; Oshima, Akira

    2015-01-01

    In Japan at present, fecal occult blood testing (FOBT) is recommended for cancer screening while routine population-based prostate-specific antigen (PSA) screening is not. In future it may be necessary to increase participation in the former and decrease it in the latter. Our objectives were to explore determinants of PSA-screening participation while simultaneously taking into account factors associated with FOBT. Data were gathered from a cross-sectional study conducted with random sampling of 6191 adults in Osaka city in 2011. Of 3244 subjects (return rate 52.4%), 936 men aged 40–64 years were analyzed using log-binomial regression to explore factors related to PSA-screening participation within 1 year. Only responders for cancer screening, defined as men who participated in either FOBT or PSA-testing, were used as main study subjects. Men who were older (prevalence ratio [PR] [95% confidence interval (CI)] = 2.17 [1.43, 3.28] for 60–64 years compared with 40–49 years), had technical or junior college education (PR [95% CI] = 1.76 [1.19, 2.59] compared with men with high school or less) and followed doctors' recommendations (PR [95% CI] = 1.50 [1.00, 2.26]) were significantly more likely to have PSA-screening after multiple variable adjustment among cancer-screening responders. Attenuation in PR of hypothesized common factors was observed among cancer-screening responders compared with the usual approach (among total subjects). Using the analytical framework to account for healthy-user bias, we found three factors related to participation in PSA-screening with attenuated association of common factors. This approach may provide a more sophisticated interpretation of participation in various screenings with different levels of recommendation. PMID:25456306

  20. Reducing the rate of preterm birth through a simple antenatal screen-and-treat programme: a retrospective cohort study.

    PubMed

    Kiss, Herbert; Petricevic, Ljubomir; Martina, Simhofer; Husslein, Peter

    2010-11-01

    To assess whether a simple screen-and-treat strategy in pregnancy, previously tested in a randomised controlled study, also effectively lowers the rate of preterm delivery under real-life conditions. In a retrospective cohort study, data were enrolled of 2986 women with singleton pregnancies presenting for routine antenatal care between 11 and 24 weeks and registering for delivery. Data of 1273 women in the intervention group were collected between 1 September 2004 and 31 August 2005. The data of 1713 women in the control group had been collected 2 years previously. All women were screened for asymptomatic vaginal infection using Gram stain, differentiating between bacterial vaginosis, vaginal candidiasis, trichomoniasis, or combinations of any of the three. Women with infection received standard treatment and follow-up. Prenatal care was the same for women in the intervention and control groups, the only difference being the absence of screening and treating for vaginal infection in the control group. The primary outcome variable was the rate of preterm delivery at less than 37 weeks. Secondary outcome variables were preterm delivery at less than 37 weeks combined with birth weights ≤ 2500 g, ≤ 2000 g, ≤ 1500 g, or ≤ 1000 g. In the intervention group, the rate of preterm birth was significantly lower than in the control group (8.2% vs. 12.1%, p < 0.0001), as was the number of preterm infants with birth weights of 2500 g or below. Also, a significant difference between groups was found for very preterm deliveries, i.e., those occurring before 33 weeks (1.9% vs. 5.4%, p < 0.0001). Integration of a simple screen-and-treatment programme for common vaginal infections into routine antenatal care led to a significant reduction in preterm births in a general population of pregnant women. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. Anthropometric Variables Accurately Predict Dual Energy X-Ray Absorptiometric-Derived Body Composition and Can Be Used to Screen for Diabetes

    PubMed Central

    Yavari, Reza; McEntee, Erin; McEntee, Michael; Brines, Michael

    2011-01-01

    The current world-wide epidemic of obesity has stimulated interest in developing simple screening methods to identify individuals with undiagnosed diabetes mellitus type 2 (DM2) or metabolic syndrome (MS). Prior work utilizing body composition obtained by sophisticated technology has shown that the ratio of abdominal fat to total fat is a good predictor for DM2 or MS. The goals of this study were to determine how well simple anthropometric variables predict the fat mass distribution as determined by dual energy x-ray absorptometry (DXA), and whether these are useful to screen for DM2 or MS within a population. To accomplish this, the body composition of 341 females spanning a wide range of body mass indices and with a 23% prevalence of DM2 and MS was determined using DXA. Stepwise linear regression models incorporating age, weight, height, waistline, and hipline predicted DXA body composition (i.e., fat mass, trunk fat, fat free mass, and total mass) with good accuracy. Using body composition as independent variables, nominal logistic regression was then performed to estimate the probability of DM2. The results show good discrimination with the receiver operating characteristic (ROC) having an area under the curve (AUC) of 0.78. The anthropometrically-derived body composition equations derived from the full DXA study group were then applied to a group of 1153 female patients selected from a general endocrinology practice. Similar to the smaller study group, the ROC from logistical regression using body composition had an AUC of 0.81 for the detection of DM2. These results are superior to screening based on questionnaires and compare favorably with published data derived from invasive testing, e.g., hemoglobin A1c. This anthropometric approach offers promise for the development of simple, inexpensive, non-invasive screening to identify individuals with metabolic dysfunction within large populations. PMID:21915276

  2. Insights into Inpatients with Poor Vision: A High Value Proposition

    PubMed Central

    Press, Valerie G.; Matthiesen, Madeleine I.; Ranadive, Alisha; Hariprasad, Seenu M.; Meltzer, David O.; Arora, Vineet M.

    2015-01-01

    Background Vision impairment is an under-recognized risk factor for adverse events among hospitalized patients, yet vision is neither routinely tested nor documented for inpatients. Low-cost ($8 and up) non-prescription ‘readers’ may be a simple, high-value intervention to improve inpatients’ vision. We aimed to study initial feasibility and efficacy of screening and correcting inpatients’ vision. Methods From June 2012 through January 2014 we began testing whether participants’ vision corrected with non-prescription lenses for eligible participants failing a vision screen (Snellen chart) performed by research assistants (RAs). Descriptive statistics and tests of comparison, including t-tests and chi-squared tests, were used when appropriate. All analyses were performed using Stata version 12 (StataCorps, College Station, TX). Results Over 800 participants’ vision was screened (n=853). Older (≥65 years; 56%) participants were more likely to have insufficient vision than younger (<65 years; 28%; p<0.001). Non-prescription readers corrected the majority of eligible participants’ vision (82%, 95/116). Discussion Among an easily identified sub-group of inpatients with poor vision, low-cost ‘readers’ successfully corrected most participants’ vision. Hospitalists and other clinicians working in the inpatient setting can play an important role in identifying opportunities to provide high-value care related to patients’ vision. PMID:25755206

  3. Prevalence of Sickle Cell Trait in the Southern Suburb of Beirut, Lebanon.

    PubMed

    El Ariss, Abdel Badih; Younes, Mohamad; Matar, Jad; Berjaoui, Zeina

    2016-01-01

    The objective of this study was to assess the prevalence, gender differences, and time trends of Sickle Cell Trait in the Southern Suburb of Beirut, Lebanon, as well as to highlight the importance of screening for Sickle Cell Trait carriers in this population. Another objective was to describe a new screening technique for Sickle Cell Trait carriers. This was a retrospective cohort study carried out at a private laboratory in the Southern Suburb of Beirut, Lebanon between 2002 and 2014. The sickling test was carried out for each patient using two methods: the classical "sodium metabisulfite sickling test", and the new "sickling test method" used in the private lab. As a confirmatory test, hemoglobin electrophoresis was run on a random sample of 223 cases which were found to be positive using the two sickling tests. A total of 899 cases were found to be positive for the sickle cell trait out of 184,105 subjects screened during the 12-year period, prevalence = 0.49% (95% CI: 0.46 - 0.52). Among the total sample, females were found to have higher prevalence, where no time trend over the studied period was noted. The haemoglobin electrophoresis method confirmed the results of this new sickling test technique among the random sample of the 223 cases. We found that the prevalence of sickle cell trait is lower as compared to other Arab countries, higher in females, with no significant time trend. The sickle cell test was found to be an accurate, simple and cheap test that could be easily added as a requirement for the pre-marital testing to screen for Sickle Cell Trait carriers.

  4. Chroma key without color restrictions based on asynchronous amplitude modulation of background illumination on retroreflective screens

    NASA Astrophysics Data System (ADS)

    Vidal, Borja; Lafuente, Juan A.

    2016-03-01

    A simple technique to avoid color limitations in image capture systems based on chroma key video composition using retroreflective screens and light-emitting diodes (LED) rings is proposed and demonstrated. The combination of an asynchronous temporal modulation onto the background illumination and simple image processing removes the usual restrictions on foreground colors in the scene. The technique removes technical constraints in stage composition, allowing its design to be purely based on artistic grounds. Since it only requires adding a very simple electronic circuit to widely used chroma keying hardware based on retroreflective screens, the technique is easily applicable to TV and filming studios.

  5. "It's a small price to pay for life": faecal occult blood test (FOBT) screening for colorectal cancer, perceived barriers and facilitators.

    PubMed

    Reeder, Anthony I

    2011-03-25

    To clarify perceptions influencing FOBT screening participation among the NZ European target population. Participants (30 female, 20 male; 50-71 years) recruited through urban (Auckland, Wellington, Christchurch) GP surgeries for in-depth, face-to-face interviews (digitally recorded and professionally transcribed verbatim). A pragmatic approach focused on aggregating transcript content. Participants believed early CRC lacked distinguishing signs and symptoms, but was treatable and suitable for screening, although slow development may undermine any sense of urgency. FOBT inaccuracies caused concern, particularly false negatives, but ongoing testing could reduce anxiety. Specimen collection was awkward, challenged social norms and individual squeamishness, but provided peace of mind, was painless, simple and private without high cost technological or professional involvement. Lacking preventive attitudes and experience of health responsibilities and screening, men were less likely to participate than women. CRC lacked public profile, highlighting government responsibility, before programme implementation, to resource high-profile education, largely through TV. General practitioner support and promotion was seen as critical. Inadequate health system capacity and resourcing was problematic. Despite challenging barriers, participants identified opportunities to increase FOBT screening participation, especially promotion to raise CRC profile, overcome perceived normative barriers and build self-efficacy. Adequate resourcing is essential to support appropriate promotion and timely programme delivery.

  6. Accessibility of standardized information of a national colorectal cancer screening program for low health literate screening invitees: A mixed method study.

    PubMed

    Fransen, Mirjam P; Dekker, Evelien; Timmermans, Daniëlle R M; Uiters, Ellen; Essink-Bot, Marie-Louise

    2017-02-01

    To explore the accessibility of standardized printed information materials of the national Dutch colorectal cancer screening program among low health literate screening invitees and to assess the effect of the information on their knowledge about colorectal cancer and the screening program. Linguistic tools were used to analyze the text and design characteristics. The accessibility, comprehensibility and relevance of the information materials were explored in interviews and in observations (n=25). The effect of the information on knowledge was assessed in an online survey (n=127). The materials employed a simple text and design. However, respondents expressed problems with the amount of information, and the difference between screening and diagnostic follow-up. Knowledge significantly increased in 10 out of 16 items after reading the information but remained low for colorectal cancer risk, sensitivity of testing, and the voluntariness of colorectal cancer screening. Despite intelligible linguistic and design characteristics, screening invitees with low health literacy had problems in accessing, comprehending and applying standard information materials on colorectal cancer screening, and lacked essential knowledge for informed decision-making about participation. To enable equal access to informed decision-making, information strategies need to be adjusted to the skills of low health literate screening invitees. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Comparison of initial stream urine samples and cervical samples for detection of human papillomavirus.

    PubMed

    Hagihara, Mao; Yamagishi, Yuka; Izumi, Koji; Miyazaki, Narimi; Suzuki, Takayoshi; Kato, Hideo; Nishiyama, Naoya; Koizumi, Yusuke; Suematsu, Hiroyuki; Mikamo, Hiroshige

    2016-08-01

    Uterine cervical cancer is a treatable and preventable cancer. Medical efforts to reduce rates of cervical cancer focus on the promotion of human papillomavirus (HPV) vaccination and the promotion of routine cervical cancer screening done by cervical cytology and cervical HPV testing. Urine-based HPV testing would be simple and noninvasive approach to screen for cervical cancer. Two biospecimens (clinician-taken sample from cervix and initial stream urine sample) were provided from a total of 240 healthy women attending for cancer screening provided for HPV testing. We have assessed the HPV detection rates among cervical samples and pellet fraction of urine samples using HPV test (Anyplex™ II HPV28 Detection kit, Seegene, Korea). Among 240 samples screened, HPV prevalence was 42.9% in pellet fractions of urine samples. The agreement between the two kinds of samples was 98.4%, k = 0.792. Discordant results were observed in 27 cases; 5 were positive only by urine samples and 22 were positive only by smear samples. Sensitivity and specificity for all HPV DNA in pellet fractions of urine using cervical samples as reference was 68.4% and 99.9%. Comparing methodologies of collection of samples for HPV detection, they showed the higher agreements for almost genotypes between cervical samples and pellet fractions of urine samples. These results suggest that urine could be a good noninvasive tool to monitor HPV infection in women. Additional research in a larger and general screening population would be needed. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  8. Improving population health or the population itself? Health technology assessment and our genetic future.

    PubMed

    Bassett, Ken; Lee, Patricia M; Green, Carolyn J; Mitchell, Lisa; Kazanjian, Arminée

    2004-01-01

    The province of British Columbia (BC), Canada is developing its first population-wide prenatal genetic screening program, known as triple-marker screening (TMS). TMS, initiated with a simple blood test, is most commonly used to screen for fetuses with the chromosomal abnormality known as Down syndrome or neural tube disorders. Women testing TMS-positive are offered diagnostic amniocentesis and, if the diagnosis is confirmed, selective second-trimester abortion. The project described in this study was initiated to address the broad range of issues arising from this testing technology and provides an example of the new type of health technology assessment (HTA) contribution emerging (and likely to become increasing necessary) in health policy development. With the advent of prenatal genetic screening programs, would-be parents gain the promise of identifying target conditions and, hence, the option of selective abortion of affected fetuses. There is considerable awareness that these developments pose challenges in every dimension (ethical, political, economic, and clinical) of the health-care environment. In the effort to construct an appropriate prenatal screening policy, therefore, administrators have understandably sought guidance from within the field of HTA. The report authors concluded that, within the restricted path open to it, the role of government is relatively clear. It has the responsibility to maintain equal access to prenatal testing, as to any other health service. It should also require maintenance of medical standards and evaluation of program performance. At the same time, policy-makers need actively to support those individuals born with disabilities and their families.

  9. Development and validation of a dementia screening tool for primary care in Taiwan: Brain Health Test

    PubMed Central

    Tsai, Ping-Huang; Liu, Jian-Liang; Lin, Ker-Neng; Chang, Chiung-Chih; Pai, Ming-Chyi; Wang, Wen-Fu; Huang, Jen-Ping; Hwang, Tzung-Jeng; Wang, Pei-Ning

    2018-01-01

    Objectives To develop a simple dementia screening tool to assist primary care physicians in identifying patients with cognitive impairment among subjects with memory complaints or at a high risk for dementia. Design The Brain Health Test (BHT) was developed by several experienced neurologists, psychiatrists, and clinical psychologists in the Taiwan Dementia Society. Validation of the BHT was conducted in the memory clinics of various levels of hospitals in Taiwan. Participants All dementia patients at the memory clinics who met the inclusion criteria of age greater or equal to 50 years were enrolled. Besides the BHT, the Mini-Mental State Examination and Clinical Dementia Rating were used to evaluate the cognition state of the patients and the severity of dementia. Results The BHT includes two parts: a risk evaluation and a cognitive test (BHT-cog). Self or informants reports of memory decline or needing help from others to manage money or medications were significantly associated with cognitive impairment. Among the risk factors evaluated in the BHT, a total risk score greater or equal to 8 was defined as a high risk for dementia. The total score for the finalized BHT-cog was 16. When the cutoff value for the BHT-cog was set to 10 for differentiating dementia and a normal mental state, the sensitivity was 91.5%, the specificity was 87.3%, the positive predictive value was 94.8%, and the negative predictive value was 80.1% The area under the receiver operating characteristic curve between dementia and healthy subjects was 0.958 (95% CI = 0.941–0.975). Conclusions The BHT is a simple tool that may be useful in primary care settings to identify high-risk patients to target for cognitive screening. PMID:29694392

  10. Experience and psychological impact of anal cancer screening in gay, bisexual and other men who have sex with men: a qualitative study.

    PubMed

    Russo, S; Mccaffery, K; Ellard, J; Poynten, M; Prestage, G; Templeton, D J; Hillman, R; Law, C; Grulich, A E

    2018-01-01

    Human papillomavirus-related anal cancer rates are increasing and are particularly high in gay, bisexual and other men who have sex with men (GBM/MSM), especially HIV-positive individuals. Although screening programs for high-risk populations have been advocated, concerns about possible adverse psychological consequences exist. This study aimed to investigate GBM/MSM's experience, understanding and emotional response to screening techniques for anal cancer to determine how best to minimise psychological distress in future programs. In-depth qualitative face-to-face interviews were conducted with 21 GBM/MSM participating in the "Study of the Prevention of Anal Cancer" in Sydney, Australia, between June 2013 and June 2014. Nonrandom, purposive sampling was used to ensure heterogeneity with respect to HIV status and screening test results. Framework analysis method was used to organise the data and identify emerging themes. Knowledge about anal cancer, human papillomavirus and the link between them was limited. Abnormal screening results affected participants' sense of well-being and were associated with anxiety and concern about developing anal cancer. HIV-negative men receiving abnormal results showed higher levels of distress compared to their HIV-positive counterparts. Consultations with general practitioners about abnormal results had an important role in increasing participants' understanding and in moderating their anxiety. Anal cancer screening should be accompanied by health education around anal cancer, its aetiology and the meaning of associated test results. Simple and effective communication strategies should be encouraged. Collaboration with general practitioners could assist the process of education and reporting test results. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Chronic pesticide poisoning from persistent low-dose exposures in Ecuadorean floriculture workers: toward validating a low-cost test battery.

    PubMed

    Breilh, Jaime; Pagliccia, Nino; Yassi, Annalee

    2012-01-01

    Chronic pesticide poisoning is difficult to detect. We sought to develop a low-cost test battery for settings such as Ecuador's floriculture industry. First we had to develop a case definition; as with all occupational diseases a case had to have both sufficient effective dose and associated health effects. For the former, using canonical discriminant analysis, we found that adding measures of protection and overall environmental stressors to occupational category and duration of exposure was useful. For the latter, factor analysis suggested three distinct manifestations of pesticide poisoning. We then determined sensitivity and specificity of various combinations of symptoms and simple neurotoxicity tests from the Pentox questionnaire, and found that doing so increased sensitivity and specificity compared to use of acethylcholinesterase alone--the current screening standard. While sensitivity and specificity varied with different case definitions, our results support the development of a low-cost test battery for screening in such settings.

  12. Prevalence of Sickle Cell Trait in the Southern Suburb of Beirut, Lebanon

    PubMed Central

    El Ariss, Abdel Badih; Younes, Mohamad; Matar, Jad; Berjaoui, Zeina

    2016-01-01

    Objective The objective of this study was to assess the prevalence, gender differences, and time trends of Sickle Cell Trait in the Southern Suburb of Beirut, Lebanon, as well as to highlight the importance of screening for Sickle Cell Trait carriers in this population. Another objective was to describe a new screening technique for Sickle Cell Trait carriers. Methods This was a retrospective cohort study carried out at a private laboratory in the Southern Suburb of Beirut, Lebanon between 2002 and 2014. The sickling test was carried out for each patient using two methods: the classical “sodium metabisulfite sickling test”, and the new “sickling test method” used in the private lab. As a confirmatory test, hemoglobin electrophoresis was run on a random sample of 223 cases which were found to be positive using the two sickling tests. Results A total of 899 cases were found to be positive for the sickle cell trait out of 184,105 subjects screened during the 12-year period, prevalence = 0.49% (95% CI: 0.46 – 0.52). Among the total sample, females were found to have higher prevalence, where no time trend over the studied period was noted. The haemoglobin electrophoresis method confirmed the results of this new sickling test technique among the random sample of the 223 cases. Conclusion We found that the prevalence of sickle cell trait is lower as compared to other Arab countries, higher in females, with no significant time trend. The sickle cell test was found to be an accurate, simple and cheap test that could be easily added as a requirement for the pre-marital testing to screen for Sickle Cell Trait carriers. PMID:26977274

  13. The microassay on a card: A rugged, portable immunoassay

    NASA Technical Reports Server (NTRS)

    Kidwell, David

    1991-01-01

    The Microassay on a Card (MAC) is a portable, hand-held, non-instrumental immunoassay that can test for the presence of a wide variety of substances in the environment. The MAC is a simple device to use. A drop of test solution is placed on one side of the card and within five minutes a color is developed on the other side in proportion to the amount of substance in the test solution, with sensitivity approaching 10 ng/ml. The MAC is self-contained and self-timed; no reagents or timing is necessary. The MAC may be configured with multiple wells to provide simultaneous testing for multiple species. As envisioned, the MAC will be employed first as an on-site screen for drugs of abuse in urine or saliva. If the MAC can be used as a screen of saliva for drugs of abuse, it could be applied to driving while intoxicated, use of drugs on the job, or testing of the identity of seized materials. With appropriate modifications, the MAC also could be used to test for environmental toxins or pollutants.

  14. Simple fluorescence-based high throughput cell viability assay for filamentous fungi.

    PubMed

    Chadha, S; Kale, S P

    2015-09-01

    Filamentous fungi are important model organisms to understand the eukaryotic process and have been frequently exploited in research and industry. These fungi are also causative agents of serious diseases in plants and humans. Disease management strategies include in vitro susceptibility testing of the fungal pathogens to environmental conditions and antifungal agents. Conventional methods used for antifungal susceptibilities are cumbersome, time-consuming and are not suitable for a large-scale analysis. Here, we report a rapid, high throughput microplate-based fluorescence method for investigating the toxicity of antifungal and stress (osmotic, salt and oxidative) agents on Magnaporthe oryzae and compared it with agar dilution method. This bioassay is optimized for the resazurin reduction to fluorescent resorufin by the fungal hyphae. Resazurin bioassay showed inhibitory rates and IC50 values comparable to the agar dilution method and to previously reported IC50 or MICs for M. oryzae and other fungi. The present method can screen range of test agents from different chemical classes with different modes of action for antifungal activities in a simple, sensitive, time and cost effective manner. A simple fluorescence-based high throughput method is developed to test the effects of stress and antifungal agents on viability of filamentous fungus Magnaporthe oryzae. This resazurin fluorescence assay can detect inhibitory effects comparable to those obtained using the growth inhibition assay with added advantages of simplicity, time and cost effectiveness. This high throughput viability assay has a great potential in large-scale screening of the chemical libraries of antifungal agents, for evaluating the effects of environmental conditions and hyphal kinetic studies in mutant and natural populations of filamentous fungi. © 2015 The Society for Applied Microbiology.

  15. A Field Trial of Alternative Targeted Screening Strategies for Chagas Disease in Arequipa, Peru

    PubMed Central

    Hunter, Gabrielle C.; Borrini-Mayorí, Katty; Ancca Juárez, Jenny; Castillo Neyra, Ricardo; Verastegui, Manuela R.; Malaga Chavez, Fernando S.; Cornejo del Carpio, Juan Geny; Córdova Benzaquen, Eleazar; Náquira, César; Gilman, Robert H.; Bern, Caryn; Levy, Michael Z.

    2012-01-01

    Background Chagas disease is endemic in the rural areas of southern Peru and a growing urban problem in the regional capital of Arequipa, population ∼860,000. It is unclear how to implement cost-effective screening programs across a large urban and periurban environment. Methods We compared four alternative screening strategies in 18 periurban communities, testing individuals in houses with 1) infected vectors; 2) high vector densities; 3) low vector densities; and 4) no vectors. Vector data were obtained from routine Ministry of Health insecticide application campaigns. We performed ring case detection (radius of 15 m) around seropositive individuals, and collected data on costs of implementation for each strategy. Results Infection was detected in 21 of 923 (2.28%) participants. Cases had lived more time on average in rural places than non-cases (7.20 years versus 3.31 years, respectively). Significant risk factors on univariate logistic regression for infection were age (OR 1.02; p = 0.041), time lived in a rural location (OR 1.04; p = 0.022), and time lived in an infested area (OR 1.04; p = 0.008). No multivariate model with these variables fit the data better than a simple model including only the time lived in an area with triatomine bugs. There was no significant difference in prevalence across the screening strategies; however a self-assessment of disease risk may have biased participation, inflating prevalence among residents of houses where no infestation was detected. Testing houses with infected-vectors was least expensive. Ring case detection yielded four secondary cases in only one community, possibly due to vector-borne transmission in this community, apparently absent in the others. Conclusions Targeted screening for urban Chagas disease is promising in areas with ongoing vector-borne transmission; however, these pockets of epidemic transmission remain difficult to detect a priori. The flexibility to adapt to the epidemiology that emerges during screening is key to an efficient case detection intervention. In heterogeneous urban environments, self-assessments of risk and simple residence history questionnaires may be useful to identify those at highest risk for Chagas disease to guide diagnostic efforts. PMID:22253939

  16. A field trial of alternative targeted screening strategies for Chagas disease in Arequipa, Peru.

    PubMed

    Hunter, Gabrielle C; Borrini-Mayorí, Katty; Ancca Juárez, Jenny; Castillo Neyra, Ricardo; Verastegui, Manuela R; Malaga Chavez, Fernando S; Cornejo del Carpio, Juan Geny; Córdova Benzaquen, Eleazar; Náquira, César; Gilman, Robert H; Bern, Caryn; Levy, Michael Z

    2012-01-01

    Chagas disease is endemic in the rural areas of southern Peru and a growing urban problem in the regional capital of Arequipa, population ∼860,000. It is unclear how to implement cost-effective screening programs across a large urban and periurban environment. We compared four alternative screening strategies in 18 periurban communities, testing individuals in houses with 1) infected vectors; 2) high vector densities; 3) low vector densities; and 4) no vectors. Vector data were obtained from routine Ministry of Health insecticide application campaigns. We performed ring case detection (radius of 15 m) around seropositive individuals, and collected data on costs of implementation for each strategy. Infection was detected in 21 of 923 (2.28%) participants. Cases had lived more time on average in rural places than non-cases (7.20 years versus 3.31 years, respectively). Significant risk factors on univariate logistic regression for infection were age (OR 1.02; p = 0.041), time lived in a rural location (OR 1.04; p = 0.022), and time lived in an infested area (OR 1.04; p = 0.008). No multivariate model with these variables fit the data better than a simple model including only the time lived in an area with triatomine bugs. There was no significant difference in prevalence across the screening strategies; however a self-assessment of disease risk may have biased participation, inflating prevalence among residents of houses where no infestation was detected. Testing houses with infected-vectors was least expensive. Ring case detection yielded four secondary cases in only one community, possibly due to vector-borne transmission in this community, apparently absent in the others. Targeted screening for urban Chagas disease is promising in areas with ongoing vector-borne transmission; however, these pockets of epidemic transmission remain difficult to detect a priori. The flexibility to adapt to the epidemiology that emerges during screening is key to an efficient case detection intervention. In heterogeneous urban environments, self-assessments of risk and simple residence history questionnaires may be useful to identify those at highest risk for Chagas disease to guide diagnostic efforts.

  17. Fetal acoustic stimulation test for early intrapartum fetal monitoring.

    PubMed

    Goonewardene, M; Hanwellage, K

    2011-03-01

    The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p < 0.001), specificity (100% vs 87%, p = 0.017), positive predictive value (100% vs 98%, p = 0.024), negative predictive value (79% vs 17%, p < 0.001) and accuracy (99%vs 64%, p < 0.001) in predicting 5 minute APGAR < 7 in the baby. FAST is a reliable screening test for assessing fetal well being in early labour. It complements the NST and is better than the NST alone.

  18. The relationship between psychological distress and baseline sports-related concussion testing.

    PubMed

    Bailey, Christopher M; Samples, Hillary L; Broshek, Donna K; Freeman, Jason R; Barth, Jeffrey T

    2010-07-01

    This study examined the effect of psychological distress on neurocognitive performance measured during baseline concussion testing. Archival data were utilized to examine correlations between personality testing and computerized baseline concussion testing. Significantly correlated personality measures were entered into linear regression analyses, predicting baseline concussion testing performance. Suicidal ideation was examined categorically. Athletes underwent testing and screening at a university athletic training facility. Participants included 47 collegiate football players 17 to 19 years old, the majority of whom were in their first year of college. Participants were administered the Concussion Resolution Index (CRI), an internet-based neurocognitive test designed to monitor and manage both at-risk and concussed athletes. Participants took the Personality Assessment Inventory (PAI), a self-administered inventory designed to measure clinical syndromes, treatment considerations, and interpersonal style. Scales and subscales from the PAI were utilized to determine the influence psychological distress had on the CRI indices: simple reaction time, complex reaction time, and processing speed. Analyses revealed several significant correlations among aspects of somatic concern, depression, anxiety, substance abuse, and suicidal ideation and CRI performance, each with at least a moderate effect. When entered into a linear regression, the block of combined psychological symptoms accounted for a significant amount of baseline CRI performance, with moderate to large effects (r = 0.23-0.30). When examined categorically, participants with suicidal ideation showed significantly slower simple reaction time and complex reaction time, with a similar trend on processing speed. Given the possibility of obscured concussion deficits after injury, implications for premature return to play, and the need to target psychological distress outright, these findings heighten the clinical importance of screening for psychological distress during baseline and post-injury concussion evaluations.

  19. A simple phenotypic method for screening of MCR-1-mediated colistin resistance.

    PubMed

    Coppi, M; Cannatelli, A; Antonelli, A; Baccani, I; Di Pilato, V; Sennati, S; Giani, T; Rossolini, G M

    2018-02-01

    To evaluate a novel method, the colistin-MAC test, for phenotypic screening of acquired colistin resistance mediated by transferable mcr-1 resistance determinants, based on colistin MIC reduction in the presence of dipicolinic acid (DPA). The colistin-MAC test consists in a broth microdilution method, in which colistin MIC is tested in the absence or presence of DPA (900 μg/mL). Overall, 74 colistin-resistant strains of Enterobacteriaceae (65 Escherichia coli and nine other species), including 61 strains carrying mcr-1-like genes and 13 strains negative for mcr genes, were evaluated with the colistin-MAC test. The presence of mcr-1-like and mcr-2-like genes was assessed by real-time PCR and end-point PCR. For 20 strains, whole-genome sequencing data were also available. A ≥8-fold reduction of colistin MIC in the presence of DPA was observed with 59 mcr-1-positive strains, including 53 E. coli of clinical origin, three E. coli transconjugants carrying MCR-1-encoding plasmids, one Enterobacter cloacae complex and two Citrobacter spp. Colistin MICs were unchanged, increased or at most reduced by twofold with the 13 mcr-negative colistin-resistant strains (nine E. coli and four Klebsiella pneumoniae), but also with two mcr-1-like-positive K. pneumoniae strains. The colistin-MAC test could be a simple phenotypic test for presumptive identification of mcr-1-positive strains among isolates of colistin-resistant E. coli, based on a ≥8-fold reduction of colistin MIC in the presence of DPA. Evaluation of the test with a larger number of strains, species and mcr-type resistance determinants would be of interest. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  20. Improved Resident Adherence to AAA Screening Guidelines via an Electronic Reminder.

    PubMed

    Sypert, David; Van Dyke, Kenneth; Dhillon, Namrata; Elliott, John O; Jordan, Kim

    The 2014 United States Preventive Services Task Force systematic review found abdominal aortic aneurysm (AAA) screening decreased related mortality by close to half. Despite the simplicity of screening, research suggests poor adherence to the recommended AAA screening guidelines. Using the quality improvement plan-study-do-act cycle, we retrospectively established poor adherence to AAA screening and poor documentation of smoking history in our resident clinic. An electronic reminder was prospectively implemented into our electronic medical record (EMR) with the goal of improving screening rates. After 1 year, a retrospective chart review was conducted. Comparisons of the pre- and post-electronic reminder intervention data were made using chi-square tests and odds ratios (OR). The purposeful AAA screening rate improved 27.8% during the intervention, 40.3% (95% confidence interval [CI]: 28.6-52.0%) versus 12.5% (95% CI: 3.1-21.9%), p = .002, suggesting patients were more likely to be screened as a result of the electronic reminder, OR = 4.73 (95% CI: 1.77-12.65). This improvement translates to a large effect size, Cohen's d = 0.86 (95% CI: 0.31-1.40). Electronic reminders are a simple EMR addition that can provide evidence-based education while improving adherence rates with preventive health screening measures.

  1. Factors influencing timely initiation and completion of gestational diabetes mellitus screening and diagnosis - a qualitative study from Tamil Nadu, India.

    PubMed

    Nielsen, Karoline Kragelund; Rheinländer, Thilde; Kapur, Anil; Damm, Peter; Seshiah, Veerasamy; Bygbjerg, Ib C

    2017-08-01

    In 2007, universal screening for gestational diabetes mellitus (GDM) was introduced in Tamil Nadu, India. To identify factors hindering or facilitating timely initiation and completion of the GDM screening and diagnosis process, our study investigated how pregnant women in rural and urban Tamil Nadu access and navigate different GDM related health services. The study was carried out in two settings: an urban private diabetes centre and a rural government primary health centre. Observations of the process of screening and diagnosis at the health centres as well as semi-structured interviews with 30 pregnant women and nine health care providers were conducted. Data was analysed using qualitative content analysis. There were significant differences in the process of GDM screening and diagnosis in the urban and rural settings. Several factors hindering or facilitating timely initiation and completion of the process were identified. Timely attendance required awareness, motivation and opportunity to attend. Women had to attend the health centre at the right time and sometimes at the right gestational age to initiate the test, wait to complete the test and obtain the test report in time to initiate further action. All these steps and requirements were influenced by factors within and outside the health system such as getting right information from health care providers, clinic timings, characteristics of the test, availability of transport, social network and support, and social norms and cultural practices. Minimising and aligning complex stepwise processes of prenatal care and GDM screening delivery and attention to the factors influencing it are important for further improving and expanding GDM screening and related services, not only in Tamil Nadu but in other similar low and middle income settings. This study stresses the importance of guidelines and diagnostic criteria which are simple and feasible on the ground.

  2. Clock Drawing Test and the diagnosis of amnestic mild cognitive impairment: can more detailed scoring systems do the work?

    PubMed

    Rubínová, Eva; Nikolai, Tomáš; Marková, Hana; Siffelová, Kamila; Laczó, Jan; Hort, Jakub; Vyhnálek, Martin

    2014-01-01

    The Clock Drawing Test is a frequently used cognitive screening test with several scoring systems in elderly populations. We compare simple and complex scoring systems and evaluate the usefulness of the combination of the Clock Drawing Test with the Mini-Mental State Examination to detect patients with mild cognitive impairment. Patients with amnestic mild cognitive impairment (n = 48) and age- and education-matched controls (n = 48) underwent neuropsychological examinations, including the Clock Drawing Test and the Mini-Mental State Examination. Clock drawings were scored by three blinded raters using one simple (6-point scale) and two complex (17- and 18-point scales) systems. The sensitivity and specificity of these scoring systems used alone and in combination with the Mini-Mental State Examination were determined. Complex scoring systems, but not the simple scoring system, were significant predictors of the amnestic mild cognitive impairment diagnosis in logistic regression analysis. At equal levels of sensitivity (87.5%), the Mini-Mental State Examination showed higher specificity (31.3%, compared with 12.5% for the 17-point Clock Drawing Test scoring scale). The combination of Clock Drawing Test and Mini-Mental State Examination scores increased the area under the curve (0.72; p < .001) and increased specificity (43.8%), but did not increase sensitivity, which remained high (85.4%). A simple 6-point scoring system for the Clock Drawing Test did not differentiate between healthy elderly and patients with amnestic mild cognitive impairment in our sample. Complex scoring systems were slightly more efficient, yet still were characterized by high rates of false-positive results. We found psychometric improvement using combined scores from the Mini-Mental State Examination and the Clock Drawing Test when complex scoring systems were used. The results of this study support the benefit of using combined scores from simple methods.

  3. Performances on the CogState and Standard Neuropsychological Batteries Among HIV Patients Without Dementia

    PubMed Central

    Overton, Edgar Turner; Kauwe, John S.K.; Paul, Rob; Tashima, Karen; Tate, David F.; Patel, Pragna; Carpenter, Chuck; Patty, David; Brooks, John T.; Clifford, David B

    2013-01-01

    HIV-associated neurocognitive disorders (HAND) remain prevalent but challenging to diagnose particularly among non-demented individuals. To determine whether a brief computerized battery correlates with formal neurocognitive testing, we identified 46 HIV-infected persons who had undergone both formal neurocognitive testing and a brief computerized battery. Simple detection tests correlated best with formal neuropsychological testing. By multivariable regression model, 53% of the variance in the composite Global Deficit Score was accounted for by elements from the brief computerized tool (p<0.01). These data confirm previous correlation data with the computerized battery, yet illustrate remaining challenges for neurocognitive screening. PMID:21877204

  4. The sensitivity and specificity of subjective memory complaints and the subjective memory rating scale, deterioration cognitive observee, mini-mental state examination, six-item screener and clock drawing test in dementia screening.

    PubMed

    Ramlall, S; Chipps, J; Bhigjee, A I; Pillay, B J

    2013-01-01

    The effectiveness of dementia screening depends on the availability of suitable screening tools with good sensitivity and specificity to confidently distinguish normal age-related cognitive decline from dementia. The aim of this study was to evaluate the discriminant validity of 7 screening measures for dementia. A sample of 140 participants aged ≥60 years living in a residential facility for the aged were assessed clinically and assigned caseness for dementia using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revised diagnostic criteria. Sensitivity and specificity of a selection of the following screening measures were tested using receiver operating characteristic (ROC) analysis for individual and combined tests: the Mini-Mental State Examination (MMSE), Six-Item Screener (SIS), Subjective Memory Complaint, Subjective Memory Complaint Clinical (SMCC), Subjective Memory Rating Scale (SMRS), Deterioration Cognitive Observee (DECO) and the Clock Drawing Test (CDT). Using ROC analyses, the SMCC, MMSE and CDT were found to be 'moderately accurate' in screening for dementia with an area under the curve (AUC) >0.70. The AUCs for the SIS (0.526), SMRS (0.661) and DECO (0.687) classified these measures as being 'less accurate'. At recommended cutoff scores, the SMCC had a sensitivity of 90.9% and specificity of 45.7%; the MMSE had a sensitivity of 63.6% and a specificity of 76.0%, and the CDT had a sensitivity of 44.4% and a specificity of 88.9%. Combining the SMCC and MMSE did not improve their predictive power except for a modest increase when using the sequential rule. The SMCC is composed of valid screening questions that have high sensitivity, are simple to administer and ideal for administration at the community or primary health care level as a first level of 'rule-out' screening. The MMSE can be included at a second stage of screening at the general hospital level and the CDT in specialist clinical settings. Sequential use of the SMCC and MMSE will improve the specificity of the former and the sensitivity of the latter. Copyright © 2013 S. Karger AG, Basel.

  5. Prevalence of HIV in pregnant women identified with a risk factor at a tertiary care hospital.

    PubMed

    Mahmud, Ghazala; Abbas, Shazra

    2009-01-01

    HIV is an epidemic quite unlike any other, combining the problems of a lifelong medical disease with immense social, psychological, economic and public health consequences. Since we are living in a global village where human interactions has become fast and frequent, diseases like HIV are no more alien to us. HIV/AIDS in Pakistan is slowly gaining recognition as a public health issue of great importance. Objectives of this study were to determine the prevalence of HIV in pregnant women identified with a high risk factor/behaviour at a tertiary care hospital. It is a Descriptive study. All pregnant women attending antenatal booking clinic were assessed via a pre-designed 'Risk assessment questionnaire'. Women identified with a risk factor were offered HIV Rapid screening test (Capillus HIV1/2). Positive (reactive) results on screening test were confirmed with ELISA. During the study period (March 2007-May 2008), out of 5263 antenatal bookings 785 (14%) women were identified with a risk factor. HIV screening test was done in 779 (99%), and 6 women refused testing. Three women (0.3%) were found positive (reactive) on screening. Two out of 3 women were confirmed positive (0.2%) on ELISA. Husbands of both women were tested and one found positive (migrant from Dubai). Second women had history of blood transfusion. Her husband was HIV negative. During the study period, in addition to 2 pregnant women diagnosed as HIV positive through ANC risk screening, 6 confirmed HIV positive women, found pregnant were referred from 'HIV Treatment Centre', Pakistan Institute of Medical Sciences (PIMS) to Prevention of Parent to Child Transmission (PPTCT) centre for obstetric care. Spouses of 5 out of 6 had history of working abroad and extramarital sexual relationships. All positive (8) women were referred to PPTCT centre for further management. A simple 'Risk Assessment Questionnaire' can help us in identifying women who need HIV screening. Sexual transmission still remains the commonest cause of HIV transmission.

  6. Investigating an Aerial Image First

    ERIC Educational Resources Information Center

    Wyrembeck, Edward P.; Elmer, Jeffrey S.

    2006-01-01

    Most introductory optics lab activities begin with students locating the real image formed by a converging lens. The method is simple and straightforward--students move a screen back and forth until the real image is in sharp focus on the screen. Students then draw a simple ray diagram to explain the observation using only two or three special…

  7. The fluorescence theatre: a cost-effective device using theatre gels for fluorescent protein and dye screening.

    PubMed

    Heil, John R; Nordeste, Ricardo F; Charles, Trevor C

    2011-04-01

    Here we report a simple cost-effective device for screening colonies on plates for expression of the monomeric red fluorescent protein mRFP1 and the fluorescent dye Nile red. This device can be built from any simple light source, in our case a Quebec Colony Counter, and cost-effective theatre gels. The device can be assembled in as little as 20 min, and it produces excellent results when screening a large number of colonies.

  8. A gel-based visual immunoassay for non-instrumental detection of chloramphenicol in food samples.

    PubMed

    Yuan, Meng; Sheng, Wei; Zhang, Yan; Wang, Junping; Yang, Yijin; Zhang, Shuguang; Goryacheva, Irina Yu; Wang, Shuo

    2012-11-02

    A gel-based non-instrumental immuno-affinity assay was developed for the rapid screening of chloramphenicol (CAP) in food samples with the limit of detection (LOD) of 1 μg L(-1). The immuno-affinity test column (IATC) consisted of a test layer containing anti-CAP antibody coupled gel, and a control layer with anti-HRP antibody coupled gel. Based on the direct competitive immuno-reaction and the horseradish peroxidase enzymatic reaction, the test results could be evaluated visually. Basically, blue color development represented the negative results, while the absence of color development represented the positive results. In this study, CAP spiked samples of raw milk, pasteurized milk, UHT milk, skimmed milk powder, acacia honey, date honey, fish and shrimp were tested. Little or none sample pretreatment was required for this assay. The whole procedure was completed within 10min. In conclusion, the gel-based immuno-affinity test is a simple, rapid, and promising on-site screening method for CAP residues in food samples, with no instrumental requirement. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Cervical cancer screening and treatment training course in El Salvador: experience and lessons learned.

    PubMed

    Masch, Rachel; Ditzian, Lauren R; April, Ayana K; Maza, Mauricio; Peralta, Ethel; Cremer, Miriam L

    2011-09-01

    Visual inspection with acetic acid (VIA) is a simple, low-cost alternative to traditional Pap smears that could greatly benefit the amount of screening and treatment available in low-resource areas, such as rural El Salvador. The objective of this study was to train Salvadoran health providers in VIA and cryotherapy using a week-long competency course. Health providers participated in the VIA training course, which consisted of 1 half-day of didactics, followed by 4 and 1 half days of clinical training. Pretests and posttests were administered. A 1-day didactic refresher course was administered to assess the quality of services being provided. Sixty-eight nurses and physicians completed the training course. Each trainee screened approximately 120 women and performed, on average, seven cryotherapy treatments. The average trainee improved his or her score by 15% on the theoretical test and 16.7% on the image test. At the completion of the 1-day refresher, average test scores were the highest among all the courses. The final assessment was based on 41 providers. The course proved a successful tool for training healthcare providers in methods of cervical cancer screening and treatment. The course is replicable in other low-resource settings in different countries. It also provided trainees with the opportunity to adapt their clinical skills in their realistic work setting.

  10. Evaluation of different phenotypic tests for detection of metallo-β-lactamases in imipenem-resistant Pseudomonas aeruginosa.

    PubMed

    Sachdeva, Rohit; Sharma, Babita; Sharma, Rajni

    2017-01-01

    Pseudomonas aeruginosa causes a wide spectrum of infections including bacteremia, pneumonia, urinary tract infection, etc., Metallo-beta-lactamase (MBL) producing P. aeruginosa is an emerging threat and cause of concern as they have emerged as one of the most feared resistance mechanisms. This study was designed to know the prevalence of MBL production in P. aeruginosa and to evaluate the four phenotypic tests for detection of MBL production in imipenem-resistant clinical isolates of P. aeruginosa . Totally, 800 isolates of P. aeruginosa isolated from various clinical samples were evaluated for carbapenem resistance and MBL production. All imipenem-resistant strains were tested for carabapenemase production by modified Hodge test. Screening for MBL production was done by double-disc synergy test and combined disc test (CDT). Confirmation of MBL production was done by the E-test (Ab BioDisk, Solna, Sweden). Out of the 800 isolates of P. aeruginosa , 250 isolates were found resistant to imipenem. Based on the results of E-test, 147 (18.37%) isolates of P. aeruginosa were positive for MBL production. The CDT has the highest sensitivity and specificity for the detection of MBL production as compared to other tests. The results of this study are indicative that MBL production is an important mechanism of carbapenem resistance among P. aeruginosa . Use of simple screening test like CDT will be crucial step toward large-scale monitoring of these emerging resistant determinants. Phenotypic test for MBL production has to be standardized, and all the isolates should be routinely screened for MBL production.

  11. Evaluation of different phenotypic tests for detection of metallo-β-lactamases in imipenem-resistant Pseudomonas aeruginosa

    PubMed Central

    Sachdeva, Rohit; Sharma, Babita; Sharma, Rajni

    2017-01-01

    PURPOSE: Pseudomonas aeruginosa causes a wide spectrum of infections including bacteremia, pneumonia, urinary tract infection, etc., Metallo-beta-lactamase (MBL) producing P. aeruginosa is an emerging threat and cause of concern as they have emerged as one of the most feared resistance mechanisms. This study was designed to know the prevalence of MBL production in P. aeruginosa and to evaluate the four phenotypic tests for detection of MBL production in imipenem-resistant clinical isolates of P. aeruginosa. METHODS: Totally, 800 isolates of P. aeruginosa isolated from various clinical samples were evaluated for carbapenem resistance and MBL production. All imipenem-resistant strains were tested for carabapenemase production by modified Hodge test. Screening for MBL production was done by double-disc synergy test and combined disc test (CDT). Confirmation of MBL production was done by the E-test (Ab BioDisk, Solna, Sweden). RESULTS: Out of the 800 isolates of P. aeruginosa, 250 isolates were found resistant to imipenem. Based on the results of E-test, 147 (18.37%) isolates of P. aeruginosa were positive for MBL production. The CDT has the highest sensitivity and specificity for the detection of MBL production as compared to other tests. CONCLUSION: The results of this study are indicative that MBL production is an important mechanism of carbapenem resistance among P. aeruginosa. Use of simple screening test like CDT will be crucial step toward large-scale monitoring of these emerging resistant determinants. Phenotypic test for MBL production has to be standardized, and all the isolates should be routinely screened for MBL production. PMID:28966485

  12. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    PubMed

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  13. Lateral-flow colloidal gold-based immunoassay for the rapid detection of deoxynivalenol with two indicator ranges.

    PubMed

    Kolosova, Anna Yu; Sibanda, Liberty; Dumoulin, Frédéric; Lewis, Janet; Duveiller, Etienne; Van Peteghem, Carlos; De Saeger, Sarah

    2008-06-02

    A lateral-flow immunoassay using a colloidal gold-labelled monoclonal antibody was developed for the rapid detection of deoxynivalenol (DON). Different parameters, such as the amount of immunoreagents, type of the materials, composition of the blocking solution and of the detector reagent mixture, were investigated to provide the optimum assay performance. The experimental results demonstrated that such a visual test had an indicator range rather than a cut-off value. Thus, tests for DON determination with two different indicator ranges of 250-500 and 1000-2000 microg kg(-1) were designed. The method allowed detection of DON at low and high concentration levels, which could be useful for research and practical purposes. The assay applied to spiked wheat and pig feed samples demonstrated accurate and reproducible results. The applicability of the developed lateral-flow test was also confirmed under real field conditions. The test strips prepared in Belgium were sent to Mexico, where they were used for the screening of DON contamination in different bread wheat entries from Fusarium Head Blight inoculated plots. The results were compared with those obtained by ELISA and LC-MS/MS. A poor correlation between ELISA and LC-MS/MS was observed. Visual results of the dipstick tests were in a good agreement with the results of the LC-MS/MS method. Coupled with a simple and fast sample preparation, this qualitative one-step test based on the visual evaluation of results did not require any equipment. Results could be obtained within 10 min. The described assay format can be used as a simple, rapid, cost-effective and robust on-site screening tool for mycotoxin contamination in different agricultural commodities.

  14. Working alone or in the presence of others: exploring social facilitation in baggage X-ray security screening tasks.

    PubMed

    Yu, Rui-feng; Wu, Xin

    2015-01-01

    This study investigated whether the mere presence of a human audience would evoke a social facilitation effect in baggage X-ray security screening tasks. A 2 (target presence: present vs. absent) ×  2 (task complexity: simple vs. complex) ×  2 (social presence: alone vs. human audience) within-subject experiment simulating a real baggage screening task was conducted. This experiment included 20 male participants. The participants' search performance in this task was recorded. The results showed that the presence of a human audience speeded up responses in simple tasks and slowed down responses in complex tasks. However, the social facilitation effect produced by the presence of a human audience had no effect on response accuracy. These findings suggested that the complexity of screening tasks should be considered when designing work organisation modes for security screening tasks. Practitioner summary: This study investigated whether the presence of a human audience could evoke a social facilitation effect in baggage X-ray security screening tasks. An experimental simulation was conducted. The results showed that the presence of a human audience facilitated the search performance of simple tasks and inhibited the performance of complex tasks.

  15. Screening of (-SEA) α-thalassaemia using an immunochromatographic strip assay for the ζ-globin chain in a population with a high prevalence and heterogeneity of haemoglobinopathies.

    PubMed

    Jomoui, Wittaya; Fucharoen, Goonnapa; Sanchaisuriya, Kanokwan; Fucharoen, Supan

    2017-01-01

    The presence of the ζ-globin chain is a good marker of (-- SEA ) α 0 -thalassaemia. We evaluated an immunochromatographic (IC) strip assay for ζ-globin in screening for (-- SEA ) α 0 -thalassaemia in a population with a high prevalence and heterogeneity of haemoglobinopathies. The study was carried out on 300 screen positive blood samples of Thai individuals. The IC strip assay for the ζ-globin chain was performed on all samples. The results were interpreted with thalassaemia genotyping using standard haemoglobin and DNA analyses. Several thalassaemia genotypes were noted. Among the 300 subjects investigated, 79 had a positive IC strip assay for ζ-globin and (-- SEA ) α 0 -thalassaemia was identified in 40 of them. No (-- SEA ) α 0 -thalassaemia was detected in the remaining 39 samples with a positive IC strip test result or in the 221 samples with a negative IC strip test result. Further DNA analysis identified α + -thalassaemia in 25 of the 39 (-- SEA ) α 0 -thalassaemia negative samples. Using this IC strip assay in combination with a conventional screening protocol for (-- SEA ) α 0 -thalassaemia could provide sensitivity and specificity of 100% and 90.4%, respectively. IC strip assay for ζ-globin is simple, rapid and does not require sophisticated equipment. Use of this test in addition to the existing screening protocol could detect potential (-- SEA ) α 0 -thalassaemia leading to a significant reduction in the workload of DNA analysis. This could be used in areas where haemoglobinopathies are prevalent and heterogeneous but molecular testing is not available. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Compounds with species and cell type specific toxicity identified in a 2000 compound drug screen of neural stem cells and rat mixed cortical neurons.

    PubMed

    Malik, Nasir; Efthymiou, Anastasia G; Mather, Karly; Chester, Nathaniel; Wang, Xiantao; Nath, Avindra; Rao, Mahendra S; Steiner, Joseph P

    2014-12-01

    Human primary neural tissue is a vital component for the quick and simple determination of chemical compound neurotoxicity in vitro. In particular, such tissue would be ideal for high-throughput screens that can be used to identify novel neurotoxic or neurotherapeutic compounds. We have previously established a high-throughput screening platform using human induced pluripotent stem cell (iPSC)-derived neural stem cells (NSCs) and neurons. In this study, we conducted a 2000 compound screen with human NSCs and rat cortical cells to identify compounds that are selectively toxic to each group. Approximately 100 of the tested compounds showed specific toxicity to human NSCs. A secondary screen of a small subset of compounds from the primary screen on human iPSCs, NSC-derived neurons, and fetal astrocytes validated the results from >80% of these compounds with some showing cell specific toxicity. Amongst those compounds were several cardiac glycosides, all of which were selectively toxic to the human cells. As the screen was able to reliably identify neurotoxicants, many with species and cell-type specificity, this study demonstrates the feasibility of this NSC-driven platform for higher-throughput neurotoxicity screens. Published by Elsevier B.V.

  17. The multidimensional perturbation value: a single metric to measure similarity and activity of treatments in high-throughput multidimensional screens.

    PubMed

    Hutz, Janna E; Nelson, Thomas; Wu, Hua; McAllister, Gregory; Moutsatsos, Ioannis; Jaeger, Savina A; Bandyopadhyay, Somnath; Nigsch, Florian; Cornett, Ben; Jenkins, Jeremy L; Selinger, Douglas W

    2013-04-01

    Screens using high-throughput, information-rich technologies such as microarrays, high-content screening (HCS), and next-generation sequencing (NGS) have become increasingly widespread. Compared with single-readout assays, these methods produce a more comprehensive picture of the effects of screened treatments. However, interpreting such multidimensional readouts is challenging. Univariate statistics such as t-tests and Z-factors cannot easily be applied to multidimensional profiles, leaving no obvious way to answer common screening questions such as "Is treatment X active in this assay?" and "Is treatment X different from (or equivalent to) treatment Y?" We have developed a simple, straightforward metric, the multidimensional perturbation value (mp-value), which can be used to answer these questions. Here, we demonstrate application of the mp-value to three data sets: a multiplexed gene expression screen of compounds and genomic reagents, a microarray-based gene expression screen of compounds, and an HCS compound screen. In all data sets, active treatments were successfully identified using the mp-value, and simulations and follow-up analyses supported the mp-value's statistical and biological validity. We believe the mp-value represents a promising way to simplify the analysis of multidimensional data while taking full advantage of its richness.

  18. Urinary free cortisol in the diagnosis of Cushing's syndrome: how useful?

    PubMed

    Odeniyi, I A; Ifedayo, A O; Fasanmade, O A; Olufemi, A F

    2013-01-01

    Cushing's syndrome results from chronic exposure to excessive circulating levels of glucocorticoids. To confirm the clinical suspicion, biochemical tests are needed. These biochemical tests include the measurement of excess total endogenous cortisol secretion assessed by 24-hour urinary free cortisol (UFC), loss of the normal feedback of the hypothalamo-pituitary-adrenal axis assessed by suppressibility after dexamethasone testing, and disturbance of the normal circadian rhythm of cortisol secretion assessed by midnight serum or salivary cortisol. We searched the Medline, Pubmed, journal articles, WHO publications and reputable textbooks relating to Cushing's syndrome using publications from 1995 to 2011. UFC has been the classic screening test used to confirm hypercortisolemia as the first step in diagnostic work-up of Cushing's syndrome. Its long-term use in clinical practice has led to emergence of significant evidence regarding the utility of UFC in the diagnosis of Cushing's syndrome. UFC would have been a simple diagnostic tool to use but for the drawbacks in the sample collection, different laboratory methods of assay, not easily determined normal range. UFC use as a screening test is not strongly favoured because cortisol is not uniformly secreted during the day, and the increased prevalence of mild, preclinical or cyclic Cushing's syndrome. A very high level of UFC negates the need for other test procedures in patients with obvious symptoms and signs of Cushing's syndrome. We therefore suggest that UFC should be used with other screening tests for Cushing's syndrome to increase diagnostic yield.

  19. New Screening Test Developed for the Blanching Resistance of Copper Alloys

    NASA Technical Reports Server (NTRS)

    Thomas-Ogbuji, Linus U.

    2004-01-01

    NASA's extensive efforts towards more efficient, safer, and more affordable space transportation include the development of new thrust-cell liner materials with improved capabilities and longer lives. For rocket engines fueled with liquid hydrogen, an important metric of liner performance is resistance to blanching, a phenomenon of localized wastage by cycles of oxidation-reduction due to local imbalance in the oxygen-fuel ratio. The current liner of the Space Shuttle Main Engine combustion chamber, a Cu-3Ag-0.5Zr alloy (NARloy-Z) is degraded in service by blanching. Heretofore, evaluating a liner material for blanching resistance involved elaborate and expensive hot-fire tests performed on rocket test stands. To simplify that evaluation, researchers at the NASA Glenn Research Center developed a screening test that uses simple, in situ oxidation-reduction cycling in a thermogravimetric analyzer (TGA). The principle behind this test is that resistance to oxidation or to the reduction of oxide, or both, implies resistance to blanching. Using this test as a preliminary tool to screen alloys for blanching resistance can improve reliability and save time and money. In this test a small polished coupon is hung in a TGA furnace at the desired (service) temperature. Oxidizing and reducing gases are introduced cyclically, in programmed amounts. Cycle durations are chosen by calibration, such that all copper oxides formed by oxidation are fully reduced in the next reduction interval. The sample weight is continuously acquired by the TGA as usual.

  20. A Simple Assay to Screen Antimicrobial Compounds Potentiating the Activity of Current Antibiotics

    PubMed Central

    Iqbal, Junaid; Kazmi, Shahana Urooj; Khan, Naveed Ahmed

    2013-01-01

    Antibiotic resistance continues to pose a significant problem in the management of bacterial infections, despite advances in antimicrobial chemotherapy and supportive care. Here, we suggest a simple, inexpensive, and easy-to-perform assay to screen antimicrobial compounds from natural products or synthetic chemical libraries for their potential to work in tandem with the available antibiotics against multiple drug-resistant bacteria. The aqueous extract of Juglans regia tree bark was tested against representative multiple drug-resistant bacteria in the aforementioned assay to determine whether it potentiates the activity of selected antibiotics. The aqueous extract of J. regia bark was added to Mueller-Hinton agar, followed by a lawn of multiple drug-resistant bacteria, Salmonella typhi or enteropathogenic E. coli. Next, filter paper discs impregnated with different classes of antibiotics were placed on the agar surface. Bacteria incubated with extract or antibiotics alone were used as controls. The results showed a significant increase (>30%) in the zone of inhibition around the aztreonam, cefuroxime, and ampicillin discs compared with bacteria incubated with the antibiotics/extract alone. In conclusion, our assay is able to detect either synergistic or additive action of J. regia extract against multiple drug-resistant bacteria when tested with a range of antibiotics. PMID:23865073

  1. A SIMPLE AND RAPID MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHT MASS SPECTROMETRY METHOD TO SCREEN FISH PLASMA SAMPLES FOR ESTROGEN-RESPONSIVE BIOMARKERS

    EPA Science Inventory

    In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...

  2. Vibration perception threshold in relation to postural control and fall risk assessment in elderly.

    PubMed

    de Mettelinge, Tine Roman; Calders, Patrick; Palmans, Tanneke; Vanden Bossche, Luc; Van Den Noortgate, Nele; Cambier, Dirk

    2013-09-01

    This study investigates (i) the potential discriminative role of a clinical measure of peripheral neuropathy (PN) in assessing postural performance and fall risk and (ii) whether the integration of a simple screening vibration perception threshold (VPT) for PN in any physical (fall risk) assessment among elderly should be recommended, even if they do not suffer from DM. One hundred and ninety-five elderly were entered in a four-group model: DM with PN (D+; n = 75), DM without PN (D-; n = 28), non-diabetic elderly with idiopathic PN (C+; n = 31) and non-diabetic elderly without PN (C-; n = 61). Posturographic sway parameters were captured during different static balance conditions (AMTI AccuGait, Watertown, MA). VPT, fall data, Mini-Mental State Examination and Clock Drawing Test were registered. Two-factor repeated-measures ANOVA was used to compare between groups and across balance conditions. The groups with PN demonstrated a strikingly comparable, though bigger sway, and a higher prospective fall incidence than their peers without PN. The indication of PN, irrespective of its cause, interferes with postural control and fall incidence. The integration of a simple screening for PN (like bio-thesiometry) in any fall risk assessment among elderly is highly recommended. Implications for Rehabilitation The indication of peripheral neuropathy (PN), irrespective of its cause, interferes with postural control and fall incidence. Therefore, the integration of a simple screening for PN (like bio-thesiometry) in any fall risk assessment among elderly is highly recommended. It might be useful to integrate somatosensory stimulation in rehabilitation programs designed for fall prevention.

  3. Comparative trial of the WHO ASSIST-linked brief intervention and simple advice for substance abuse in primary care.

    PubMed

    Assanangkornchai, Sawitri; Nima, Patimoh; McNeil, Edward B; Edwards, J Guy

    2015-12-01

    To help decrease the burden of substance-related problems, the World Health Organization developed the Alcohol, Smoking, Substance Involvement Screening Test (ASSIST) - a sensitive screening questionnaire to help identify misuse of alcohol and other substances - linked to Brief Intervention (BI). This paper compares the effectiveness of the ASSIST followed either by its linked BI or by simple advice (SA). The trial was conducted in southern Thailand. The ASSIST was used to screen patients attending primary care units and categorise them into 'low-risk', 'moderate-risk' and 'high-risk' groups. Patients at 'moderate-risk' were randomised to receive ASSIST-linked BI (n=120) or SA (n=116). The outcome measures were changes in the ASSIST-Specific Substance Involvement Scores (ASSIST-SSIS), ASSIST-Total Substance Involvement Scores (ASSIST-TSIS) and proportions of patients whose scores at three and six months had decreased from the 'moderate-risk' to 'low-risk' category. 147 patients (72 BI; 75 SA) completed the six-month trial. There were significant reductions in both ASSIST-SSIS and ASSIST-TSIS, with no significant difference between groups. The percentages of patients converted to the 'low-risk' category were 36.7% and 38.8% at month 3, and 53.3% and 53.4% at month 6, for the BI and SA groups, respectively. In conclusion, in primary care administering the ASSIST and telling patients their score, followed either by formal brief intervention or simple advice, are equally effective in decreasing substance use for up to six months. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    PubMed

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  5. Fecal Molecular Markers for Colorectal Cancer Screening

    PubMed Central

    Kanthan, Rani; Senger, Jenna-Lynn; Kanthan, Selliah Chandra

    2012-01-01

    Despite multiple screening techniques, including colonoscopy, flexible sigmoidoscopy, radiological imaging, and fecal occult blood testing, colorectal cancer remains a leading cause of death. As these techniques improve, their sensitivity to detect malignant lesions is increasing; however, detection of precursor lesions remains problematic and has generated a lack of general acceptance for their widespread usage. Early detection by an accurate, noninvasive, cost-effective, simple-to-use screening technique is central to decreasing the incidence and mortality of this disease. Recent advances in the development of molecular markers in faecal specimens are encouraging for its use as a screening tool. Genetic mutations and epigenetic alterations that result from the carcinogenetic process can be detected by coprocytobiology in the colonocytes exfoliated from the lesion into the fecal matter. These markers have shown promising sensitivity and specificity in the detection of both malignant and premalignant lesions and are gaining popularity as a noninvasive technique that is representative of the entire colon. In this paper, we summarize the genetic and epigenetic fecal molecular markers that have been identified as potential targets in the screening of colorectal cancer. PMID:22969796

  6. Environmental screening tools for assessment of infrastructure plans based on biodiversity preservation and global warming (PEIT, Spain)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia-Montero, Luis G., E-mail: luisgonzaga.garcia@upm.e; Lopez, Elena, E-mail: elopez@caminos.upm.e; Monzon, Andres, E-mail: amonzon@caminos.upm.e

    Most Strategic Environmental Assessment (SEA) research has been concerned with SEA as a procedure, and there have been relatively few developments and tests of analytical methodologies. The first stage of the SEA is the 'screening', which is the process whereby a decision is taken on whether or not SEA is required for a particular programme or plan. The effectiveness of screening and SEA procedures will depend on how well the assessment fits into the planning from the early stages of the decision-making process. However, it is difficult to prepare the environmental screening for an infrastructure plan involving a whole country.more » To be useful, such methodologies must be fast and simple. We have developed two screening tools which would make it possible to estimate promptly the overall impact an infrastructure plan might have on biodiversity and global warming for a whole country, in order to generate planning alternatives, and to determine whether or not SEA is required for a particular infrastructure plan.« less

  7. HTS-Net: An integrated regulome-interactome approach for establishing network regulation models in high-throughput screenings

    PubMed Central

    Rioualen, Claire; Da Costa, Quentin; Chetrit, Bernard; Charafe-Jauffret, Emmanuelle; Ginestier, Christophe

    2017-01-01

    High-throughput RNAi screenings (HTS) allow quantifying the impact of the deletion of each gene in any particular function, from virus-host interactions to cell differentiation. However, there has been less development for functional analysis tools dedicated to RNAi analyses. HTS-Net, a network-based analysis program, was developed to identify gene regulatory modules impacted in high-throughput screenings, by integrating transcription factors-target genes interaction data (regulome) and protein-protein interaction networks (interactome) on top of screening z-scores. HTS-Net produces exhaustive HTML reports for results navigation and exploration. HTS-Net is a new pipeline for RNA interference screening analyses that proves better performance than simple gene rankings by z-scores, by re-prioritizing genes and replacing them in their biological context, as shown by the three studies that we reanalyzed. Formatted input data for the three studied datasets, source code and web site for testing the system are available from the companion web site at http://htsnet.marseille.inserm.fr/. We also compared our program with existing algorithms (CARD and hotnet2). PMID:28949986

  8. Underscreening in concentrated electrolytes.

    PubMed

    Lee, Alpha A; Perez-Martinez, Carla S; Smith, Alexander M; Perkin, Susan

    2017-07-01

    Screening of a surface charge by an electrolyte and the resulting interaction energy between charged objects is of fundamental importance in scenarios from bio-molecular interactions to energy storage. The conventional wisdom is that the interaction energy decays exponentially with object separation and the decay length is a decreasing function of ion concentration; the interaction is thus negligible in a concentrated electrolyte. Contrary to this conventional wisdom, we have shown by surface force measurements that the decay length is an increasing function of ion concentration and Bjerrum length for concentrated electrolytes. In this paper we report surface force measurements to test directly the scaling of the screening length with Bjerrum length. Furthermore, we identify a relationship between the concentration dependence of this screening length and empirical measurements of activity coefficient and differential capacitance. The dependence of the screening length on the ion concentration and the Bjerrum length can be explained by a simple scaling conjecture based on the physical intuition that solvent molecules, rather than ions, are charge carriers in a concentrated electrolyte.

  9. Using the emergency department as a screening site for high blood pressure. A method for improving hypertension detection and appropriate referral.

    PubMed

    Mamon, J; Green, L; Levine, D M; Gibson, G; Gurley, H T

    1987-08-01

    This study describes the development and testing of a high blood pressure protocol for use in emergency departments (ED) to enhance detection of those patients appropriate for subsequent referral. The protocol involves two serial blood pressure measurements and a patient interview to determine: 1) previous history of high blood pressure (HBP), 2) treatment in past year for HBP, and 3) usual source of medical care. The accuracy of patient reporting was validated by comparison with the patients' hospital record (reflecting outpatient and inpatient visits). Results indicate that these self-reports have high levels of sensitivity (range 90-100%) and specificity (range 79-96%). Use of the additional patient information increased the sensitivity of the screening protocol in identifying when and where a patient should be referred. Use of this methodology indicates that the protocol is a simple and effective method for HBP screening. The findings also suggest that the ED is an ideal site for screening the "hard-to-reach" hypertensive population.

  10. Validation of Version 3.0 of the Breast Cancer Genetics Referral Screening Tool (B-RST™).

    PubMed

    Bellcross, Cecelia; Hermstad, April; Tallo, Christine; Stanislaw, Christine

    2018-05-08

    Despite increased awareness of hereditary breast and ovarian cancer among clinicians and the public, many BRCA1/2 mutation carriers remain unaware of their risk status. The Breast Cancer Genetics Referral Screening Tool (B-RST™) was created and validated to easily identify individuals at increased risk for hereditary breast and ovarian cancer for referral to cancer genetics services. The purpose of this study was to revise B-RST™ to maximize sensitivity against BRCA1/2 mutation status. We analyzed pedigrees of 277 individuals who had undergone BRCA1/2 testing to determine modifications to the B-RST™ 2.0 algorithm that would maximize sensitivity for mutations, while maintaining simplicity. We used McNemar's chi-square test to compare validation measures between the revised version (3.0) and the 2.0 version. Algorithmic changes made to B-RST™ 2.0 increased the sensitivity against BRCA1/2 mutation analysis from 71.1 to 94.0% (P < 0.0001). While specificity decreased, all screen-positive individuals were appropriate for cancer genetics referral, the primary purpose of the tool. Despite calls for BRCA1/2 population screening, there remains a critical need to identify those most at risk who should receive cancer genetics services. B-RST™ version 3.0 demonstrates high sensitivity for BRCA1/2 mutations, yet remains a simple and quick screening tool for at-risk individuals.

  11. Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs

    NASA Astrophysics Data System (ADS)

    Lee, Eugene K.; Kurokawa, Yosuke K.; Tu, Robin; George, Steven C.; Khine, Michelle

    2015-07-01

    Current preclinical screening methods do not adequately detect cardiotoxicity. Using human induced pluripotent stem cell-derived cardiomyocytes (iPS-CMs), more physiologically relevant preclinical or patient-specific screening to detect potential cardiotoxic effects of drug candidates may be possible. However, one of the persistent challenges for developing a high-throughput drug screening platform using iPS-CMs is the need to develop a simple and reliable method to measure key electrophysiological and contractile parameters. To address this need, we have developed a platform that combines machine learning paired with brightfield optical flow as a simple and robust tool that can automate the detection of cardiomyocyte drug effects. Using three cardioactive drugs of different mechanisms, including those with primarily electrophysiological effects, we demonstrate the general applicability of this screening method to detect subtle changes in cardiomyocyte contraction. Requiring only brightfield images of cardiomyocyte contractions, we detect changes in cardiomyocyte contraction comparable to - and even superior to - fluorescence readouts. This automated method serves as a widely applicable screening tool to characterize the effects of drugs on cardiomyocyte function.

  12. Materials selection for long life in low earth orbit - A critical evaluation of atomic oxygen testing with thermal atom systems

    NASA Technical Reports Server (NTRS)

    Koontz, S. L.; Albyn, K.; Leger, L.

    1990-01-01

    The use of thermal atom test methods as a materials selection and screening technique for low-earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined in thermal atom environments are compared with those observed in LEO and in high-quality LEO simulations. Reaction efficiencies (cu cm/atom) measured in a new type of thermal atom apparatus are one-thousandth to one ten-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of eight in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain speciic thermal atom test environments can be used as reliable materials screening tools.

  13. Rapid methodology to screen flame retardants in upholstered furniture for compliance with new California labeling law (SB 1019).

    PubMed

    Petreas, Myrto; Gill, Ranjit; Takaku-Pugh, Sayaka; Lytle, Eric; Parry, Emily; Wang, Miaomiao; Quinn, John; Park, June-Soo

    2016-06-01

    In response to concerns regarding the widespread use of flame retardants, the California Legislature passed a law (SB1019) requiring labels on furniture products to indicate whether they do or do not contain flame retardants. To support the enforcement of the new law, our laboratory developed a step-wise, screening approach to test for brominated (BFR) and phosphorus-based flame retardants (OPFRs) in several types of furniture components (foam, fabric, batting, plumage, etc.). We used X-Ray Fluorescence (XRF) to screen for the presence of Br (and other elements) and Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES) to identify and measure the concentration of P (and other elements). The same samples were also extracted by dichloromethane using sonication and analyzed by a single injection into a Gas Chromatograph - Tandem Mass Spectrometer to obtain concentrations of specific BFRs and OPFRs. Our approach showed excellent screening potential for Br and Sb by XRF and for P by ICP-OES, with both tests having predictive values of a negative equal to 1. To explore and screen for flame retardants in products not included in our current list of target chemicals, we used Liquid Chromatography/Time-of-Flight Mass Spectrometry operated with electrospray ionization, to identify additional flame retardants to be incorporated in quantitative methods. We are making all our methodologies public to facilitate simple and low cost methods that can help manufacturers and suppliers have their products tested and correctly labeled, ultimately benefitting the consumer. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Interatomic potential at small internuclear distances. A simple formula for the screening constant

    NASA Astrophysics Data System (ADS)

    Zinoviev, A. N.

    2017-09-01

    A simple formula for estimating the screening constant has been proposed. This formula fits well experimental data on the interaction potentials. Quantitative description of the experiment for the effect of electronic screening on the nuclear synthesis reaction cross-section for the D+-D system has been obtained. A conclusion has been made that the differences between the measured cross-sections and their theoretically predicted values, which take place in more complicated cases nuclear synthesis reactions, are not caused by uncertainties in the knowledge of potentials.

  15. Impact of the Hepatitis Testing and Linkage to Care (HepTLC) Initiative on Linkage to Care for Minnesota Refugees with Hepatitis B, 2012-2014.

    PubMed

    Linde, Ann C; Sweet, Kristin A; Nelson, Kailey; Mamo, Blain; Chute, Sara M

    2016-01-01

    The Hepatitis Testing and Linkage to Care (HepTLC) initiative promoted viral hepatitis B and hepatitis C screening, posttest counseling, and linkage to care at 34 U.S. sites from 2012 to 2014. Through the HepTLC initiative, the Minnesota Department of Health (MDH) and clinic partners began conducting linkage-to-care activities with hepatitis B-positive refugees in October 2012. This intervention provided culturally appropriate support to link refugees to follow-up care for hepatitis B. MDH refugee health and viral hepatitis surveillance programs, along with clinics that screened newly arrived refugees in Hennepin and Ramsey counties in Minnesota, collaborated on the project, which took place from October 1, 2012, through September 30, 2014. Bilingual care navigators contacted refugees to provide education, make appointments, and arrange transportation. We compared the linkage-to-care rate for participants with the rates for refugees screened the year before project launch using a two-sample test of proportions. In the year preceding the project (October 2011 through September 2012), 87 newly arrived refugees had a positive hepatitis B surface antigen (HBsAg) test. Fifty-six (64%) refugees received follow-up care, 12 (14%) refugees did not receive follow-up care, and 19 (22%) refugees could not be located and had no record of follow-up care. During the project, 174 HBsAg-positive, newly arrived refugees were screened. Of those 174 refugees, 162 (93%) received follow-up care, seven (4%) did not receive follow-up care, and five (3%) could not be located and had no record of follow-up care. The one-year linkage-to-care rate for project participants (93%) was significantly higher than the rate for refugees screened the previous year (64%) (p<0.001). In the context of a strong screening and surveillance infrastructure, a simple intervention improved the linkage-to-care rate for HBsAg-positive refugees.

  16. Impact of the Hepatitis Testing and Linkage to Care (HepTLC) Initiative on Linkage to Care for Minnesota Refugees with Hepatitis B, 2012–2014

    PubMed Central

    Sweet, Kristin A.; Nelson, Kailey; Mamo, Blain; Chute, Sara M.

    2016-01-01

    Objective The Hepatitis Testing and Linkage to Care (HepTLC) initiative promoted viral hepatitis B and hepatitis C screening, posttest counseling, and linkage to care at 34 U.S. sites from 2012 to 2014. Through the HepTLC initiative, the Minnesota Department of Health (MDH) and clinic partners began conducting linkage-to-care activities with hepatitis B-positive refugees in October 2012. This intervention provided culturally appropriate support to link refugees to follow-up care for hepatitis B. Methods MDH refugee health and viral hepatitis surveillance programs, along with clinics that screened newly arrived refugees in Hennepin and Ramsey counties in Minnesota, collaborated on the project, which took place from October 1, 2012, through September 30, 2014. Bilingual care navigators contacted refugees to provide education, make appointments, and arrange transportation. We compared the linkage-to-care rate for participants with the rates for refugees screened the year before project launch using a two-sample test of proportions. Results In the year preceding the project (October 2011 through September 2012), 87 newly arrived refugees had a positive hepatitis B surface antigen (HBsAg) test. Fifty-six (64%) refugees received follow-up care, 12 (14%) refugees did not receive follow-up care, and 19 (22%) refugees could not be located and had no record of follow-up care. During the project, 174 HBsAg-positive, newly arrived refugees were screened. Of those 174 refugees, 162 (93%) received follow-up care, seven (4%) did not receive follow-up care, and five (3%) could not be located and had no record of follow-up care. The one-year linkage-to-care rate for project participants (93%) was significantly higher than the rate for refugees screened the previous year (64%) (p<0.001). Conclusion In the context of a strong screening and surveillance infrastructure, a simple intervention improved the linkage-to-care rate for HBsAg-positive refugees. PMID:27168670

  17. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots

    PubMed Central

    2010-01-01

    Background Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. Methods A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Results Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. Conclusions The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration. PMID:20684792

  18. Population screening for glucose-6-phosphate dehydrogenase deficiencies in Isabel Province, Solomon Islands, using a modified enzyme assay on filter paper dried bloodspots.

    PubMed

    Kuwahata, Melissa; Wijesinghe, Rushika; Ho, Mei-Fong; Pelecanos, Anita; Bobogare, Albino; Landry, Losi; Bugora, Hugo; Vallely, Andrew; McCarthy, James

    2010-08-05

    Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration.

  19. A simple and sensitive high-throughput GFP screening in woody and herbaceous plants.

    PubMed

    Hily, Jean-Michel; Liu, Zongrang

    2009-03-01

    Green fluorescent protein (GFP) has been used widely as a powerful bioluminescent reporter, but its visualization by existing methods in tissues or whole plants and its utilization for high-throughput screening remains challenging in many species. Here, we report a fluorescence image analyzer-based method for GFP detection and its utility for high-throughput screening of transformed plants. Of three detection methods tested, the Typhoon fluorescence scanner was able to detect GFP fluorescence in all Arabidopsis thaliana tissues and apple leaves, while regular fluorescence microscopy detected it only in Arabidopsis flowers and siliques but barely in the leaves of either Arabidopsis or apple. The hand-held UV illumination method failed in all tissues of both species. Additionally, the Typhoon imager was able to detect GFP fluorescence in both green and non-green tissues of Arabidopsis seedlings as well as in imbibed seeds, qualifying it as a high-throughput screening tool, which was further demonstrated by screening the seedlings of primary transformed T(0) seeds. Of the 30,000 germinating Arabidopsis seedlings screened, at least 69 GFP-positive lines were identified, accounting for an approximately 0.23% transformation efficiency. About 14,000 seedlings grown in 16 Petri plates could be screened within an hour, making the screening process significantly more efficient and robust than any other existing high-throughput screening method for transgenic plants.

  20. Visual detection technique for efficient screening and isolation of Salmonella based on a novel enrichment assay using chromatography membrane.

    PubMed

    Tang, F; Xiong, Y; Zhang, H; Wu, K; Xiang, Y; Shao, J-B; Ai, H-W; Xiang, Y-P; Zheng, X-L; Lv, J-R; Sun, H; Bao, L-S; Zhang, Z; Hu, H-B; Zhang, J-Y; Chen, L; Lu, J; Liu, W-Y; Mei, H; Ma, Y; Xu, C-F; Fang, A-Y; Gu, M; Xu, C-Y; Chen, Y; Chen, Z; Sun, Z-Y

    2016-03-01

    To detect Salmonella more efficiently and isolate strains more easily, a novel and simple detection method that uses an enrichment assay and two chromogenic reactions on a chromatography membrane was developed. Grade 3 chromatography paper is used as functionalized solid phase support (SPS), which contains specially optimized medium. One reaction for screening is based on the sulfate-reducing capacity of Salmonella. Hydrogen sulfide (H2S) generated by Salmonella reacts with ammonium ferric citrate to produce black colored ferrous sulfide. Another reaction is based on Salmonella C8 esterase that is unique for Enterobacteriaceae except Serratia and interacts with 4-methylumbelliferyl caprylate (MUCAP) to produce fluorescent umbelliferone, which is visible under ultraviolet light. A very low detection limit (10(1) CFU ml(-1)) for Salmonella was achieved on the background of 10(5) CFU ml(-1) Escherichia coli. More importantly, testing with more than 1,000 anal samples indicated that our method has a high positive detection rate and is relatively low cost, compared with the traditional culture-based method. It took only 1 day for the preliminary screening and 2 days to efficiently isolate the Salmonella cells, indicating that the new assay is specific, rapid, and simple for Salmonella detection. In contrast to the traditional culture-based method, this method can be easily used to screen and isolate targeted strains with the naked eye. The results of quantitative and comparative experiments showed that the visual detection technique is an efficient alternative method for the screening of Salmonella spp. in many applications of large-sized samples related to public health surveillance.

  1. Hearing loss screening tool (COBRA score) for newborns in primary care setting

    PubMed Central

    Poonual, Watcharapol; Navacharoen, Niramon; Kangsanarak, Jaran; Namwongprom, Sirianong

    2017-01-01

    Purpose To develop and evaluate a simple screening tool to assess hearing loss in newborns. A derived score was compared with the standard clinical practice tool. Methods This cohort study was designed to screen the hearing of newborns using transiently evoked otoacoustic emission and auditory brain stem response, and to determine the risk factors associated with hearing loss of newborns in 3 tertiary hospitals in Northern Thailand. Data were prospectively collected from November 1, 2010 to May 31, 2012. To develop the risk score, clinical-risk indicators were measured by Poisson risk regression. The regression coefficients were transformed into item scores dividing each regression-coefficient with the smallest coefficient in the model, rounding the number to its nearest integer, and adding up to a total score. Results Five clinical risk factors (Craniofacial anomaly, Ototoxicity, Birth weight, family history [Relative] of congenital sensorineural hearing loss, and Apgar score) were included in our COBRA score. The screening tool detected, by area under the receiver operating characteristic curve, more than 80% of existing hearing loss. The positive-likelihood ratio of hearing loss in patients with scores of 4, 6, and 8 were 25.21 (95% confidence interval [CI], 14.69–43.26), 58.52 (95% CI, 36.26–94.44), and 51.56 (95% CI, 33.74–78.82), respectively. This result was similar to the standard tool (The Joint Committee on Infant Hearing) of 26.72 (95% CI, 20.59–34.66). Conclusion A simple screening tool of five predictors provides good prediction indices for newborn hearing loss, which may motivate parents to bring children for further appropriate testing and investigations. PMID:29234358

  2. A Korean rheumatic diseases screening questionnaire.

    PubMed Central

    Lee, Hye-Soon; Oh, Kwang-Taek; Kim, Tae-Hwan; Jung, Sungsoo; Yoo, Dae-Hyun; Bae, Sang-Cheol

    2003-01-01

    The aim of our study was to develop a Korean rheumatic diseases-screening questionnaire. The questionnaire was constructed based on American College of Rheumatology criteria for rheumatic diseases and a connective tissue diseases screening questionnaire. Two groups of patients were selected and completed the questionnaire: (i) those with osteoarthritis (n=46), rheumatoid arthritis (n=52), systemic lupus erythematosus (n=50), scleroderma (n=8), polymyositis or dermatomyositis (n=7), Sjogren's disease (n=4), and mixed connective-tissue disease (n=9) as case subjects; and (ii) those with fibromyalgia (n=8) and general disease without evidence of any rheumatic disease (n=72) as controls. Laboratory results were analyzed for correlation with actual data using kappa (kappa) statistics. Test-retest reliability was performed in 12 patients, and showed strong agreement between the first and second interviews (kappa=0.91). The sensitivity of the questionnaire ranged from 77.8 to 100%, and specificity ranged from 68.8 to 95.0%. Negative predictive values were very high in the general population, from 98.4 to 99.99%. The kappa statistic for agreement between laboratory items was 0.22-0.56, except for rheumatoid factor, antinuclear antibody test, and muscle enzyme level. We have developed a simple and sensitive Korean rheumatic diseases-screening questionnaire for the epidemiologic study of rheumatic diseases in Korea. PMID:12692412

  3. Evaluation of a Microbial Sensor as a Tool for Antimicrobial Activity Test of Cosmetic Preservatives.

    PubMed

    Gomyo, Hideyuki; Ookawa, Masaki; Oshibuchi, Kota; Sugamura, Yuriko; Hosokawa, Masahito; Shionoiri, Nozomi; Maeda, Yoshiaki; Matsunaga, Tadashi; Tanaka, Tsuyoshi

    2015-01-01

    For high-throughput screening of novel cosmetic preservatives, a rapid and simple assay to evaluate the antimicrobial activities should be developed because the conventional agar dilution method is time-consuming and labor-intensive. To address this issue, we evaluated a microbial sensor as a tool for rapid antimicrobial activity testing. The sensor consists of an oxygen electrode and a filter membrane that holds the test microorganisms, Staphylococcus aureus and Candida albicans. The antimicrobial activity of the tested cosmetic preservative was evaluated by measuring the current increases corresponding to the decreases in oxygen consumption in the microbial respiration. The current increases detected by the sensor showed positive correlation to the concentrations of two commercially used preservatives, chlorphenesin and 2-phenoxyethanol. The same tendency was also observed when a model cosmetic product was used as a preservative solvent, indicating the feasibility in practical use. Furthermore, the microbial sensor and microfluidic flow-cell was assembled to achieve sequential measurements. The sensor system presented in this study could be useful in large-scale screening experiments.

  4. An ongoing six-year innovative osteoporosis disease management program: challenges and success in an IPA physician group environment.

    PubMed

    Woo, Ann; Hittell, Jodi; Beardsley, Carrie; Noh, Charles; Stoukides, Cheryl A; Kaul, Alan F

    2004-01-01

    The goal of this ongoing comprehensive osteoporosis disease management initiative is to provide the adult primary care physicians' (PCPs) offices with a program enabling them to systematically identify and manage their population for osteoporosis. For over six years, Hill Physicians Medical Group (Hill Physicians) has implemented multiple strategies to develop a best practice for identifying and treating members who were candidates for osteoporosis therapy. Numerous tools were used to support this disease management effort, including: evidence-based clinical practice guidelines, patient education sessions, the Simple Calculated Osteoporosis Risk Estimation (SCORE) questionnaire tool, member specific reports for PCPs, targeted member mailings, office-based Peripheral Instantaneous X-ray Imaging (PIXI) test and counseling, dual x-ray absorptiometry (DEXA) scan guidelines, and web-based Electronic Simple Calculated Osteoporosis Risk Estimation (eSCORE) questionnaire tools. Hill Physicians tabulated results for patients who completed 2649 SCORE tests, screened 978 patients with PIXI tests, and identified 338 osteopenic and 124 osteoporotic patients. The preliminary results of this unique six-year ongoing educational initiative are slow but promising. New physician offices express interest in participating and those offices that have participated in the program continue to screen for osteoporosis. Hill Physicians' message is consistent and is communicated to the physicians repeatedly in different ways in accordance with the principles of educational outreach. Physicians who have conducted the program have positive feedback from their patients and office staff and have begun to communicate their experience to their peers.

  5. Salivary diagnostics and its impact in dentistry, research, education, and the professional community.

    PubMed

    Slavkin, H C; Fox, C H; Meyer, D M

    2011-10-01

    Oral fluid-based (salivary) tests have the potential to create practical, point-of-care clinical instruments that are convenient, practical, and comfortable to use in dentistry and medicine. Currently, there are no simple, accurate, and inexpensive sampling, screening, or detection methods to support definitive diagnostic platforms across dental and medical disciplines. Though the benefits from advancing screening and detection technologies seem eminent, analytical, chemical, molecular, genetic, and protein markers are still under development. Clinical applications in patient care must be validated independently to ensure that they are clinically accurate, reliable, precise, and uniformly consistent for screening and detecting specific diseases or conditions. As technology designed to improve patient care through risk assessment, prevention, and disease management is transferred into clinical practice, dentistry may need to reassess its role in general health care. © International & American Associations for Dental Research

  6. Screening of Compounds Toxicity against Human Monocytic cell line-THP-1 by Flow Cytometry

    PubMed Central

    Pick, Neora; Cameron, Scott; Arad, Dorit

    2004-01-01

    The worldwide rapid increase in bacterial resistance to numerous antibiotics requires on-going development of new drugs to enter the market. As the development of new antibiotics is lengthy and costly, early monitoring of compound's toxicity is essential in the development of novel agents. Our interest is in a rapid, simple, high throughput screening method to assess cytotoxicity induced by potential agents. Some intracellular pathogens, such as Mycobacterium tuberculosis primary site of infection is human alveolar macrophages. Thus, evaluation of candidate drugs for macrophage toxicity is crucial. Protocols for high throughput drug toxicity screening of macrophages using flow cytometry are lacking in the literature. For this application we modified a preexisting technique, propidium iodide (PI) exclusion staining and utilized it for rapid toxicity tests. Samples were prepared in 96 well plates and analyzed by flow cytometry, which allowed for rapid, inexpensive and precise assessment of compound's toxicity associated with cell death. PMID:15472722

  7. An extension of the Coconut Cream Agar method to screen Penicillium citrinum isolates for citrinin production.

    PubMed

    Mohamed, S; Flint, S; Palmer, J; Fletcher, G C; Pitt, J I

    2013-09-01

    A simple and rapid screening method was developed for the detection of citrinin in fungal cultures using Coconut Cream Agar (CCA) described previously for detecting aflatoxin and ochratoxin A. Fifteen isolates of Penicillium citrinum were inoculated onto CCA and incubated at 25 and 30°C for 10 days. All isolates produced a distinct yellow green fluorescence on CCA when the reverse side of the agar plates were viewed under long wavelength UV light. Detection was optimal at 25°C after four to 5 days of incubation. Isolates positive by the CCA method also tested positive for citrinin production by the TLC agar plug method after growth on CCA, Czapek yeast extract agar and yeast extract sucrose agar. Control cultures were negative by both methods, indicating that the CCA Petri dish method was suitable for screening cultures for citrinin production. © 2013 The Society for Applied Microbiology.

  8. Does routine psychosocial screening improve referral to psychosocial care providers and patient-radiotherapist communication? A cluster randomized controlled trial.

    PubMed

    Braeken, Anna P B M; Lechner, Lilian; Eekers, Daniëlle B P; Houben, Ruud M A; van Gils, Francis C J M; Ambergen, Ton; Kempen, Gertrudis I J M

    2013-11-01

    This study tests whether using a screening instrument improves referral to psychosocial care providers (e.g. psychologist) and facilitates patient-radiotherapist communication. A cluster randomized controlled trial was used. Fourteen radiotherapists were randomly allocated to the experimental or control group and 568 of their patients received care in accordance with the group to which their radiotherapist was allocated. Patients in the experimental group were asked to complete a screening instrument before and at the end of the radiation treatment period. All patients were requested to complete questionnaires concerning patient-physician communication after the first consultation and concerning psychosocial care 3 and 12 months post-intervention. Patients who completed the screening instrument were referred to social workers at an earlier stage than patients who did not (P<0.01). No effects were observed for numbers of referred patients, or for improved patient-radiotherapist communication. Our results suggest that a simple screening procedure can be valuable for the timely treatment of psychosocial problems in patients. Future efforts should be directed at appropriate timing of screening and enhancing physicians' awareness regarding the importance of identifying, discussing and treating psychosocial problems in cancer patients. Psychosocial screening can be enhanced by effective radiotherapist-patient communication. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method).

    PubMed

    Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini

    2016-11-15

    For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Population screening for coeliac disease in primary care by district nurses using a rapid antibody test: diagnostic accuracy and feasibility study

    PubMed Central

    2007-01-01

    Objective To evaluate the feasibility and diagnostic accuracy of screening for coeliac disease by rapid detection of IgA antibodies to tissue transglutaminase performed in primary care. Design District nurses screened 6 year old children using rapid antibody testing of finger prick blood. They also collected capillary blood samples for laboratory determination of IgA and IgG antibodies to endomysium and IgA antibodies to tissue transglutaminase. Children with positive rapid test results were directly sent for biopsy of the small intestine. Setting Primary care in Jász-Nagykun-Szolnok county, Hungary. Participants 2690 children (77% of 6 year olds living in the county) and 120 nurses. Main outcome measures Positivity for antibodies to endomysium or transglutaminase in the laboratory and coeliac disease confirmed at biopsy. Results 37 children (1.4%, 95% confidence interval 0.9% to 1.8%) had biopsy confirmed coeliac disease. Only five of these children had been diagnosed clinically before screening. Rapid testing had a 78.1% sensitivity (70.0% to 89.3%) and 100% specificity (88.4% to 100%) for a final diagnosis of coeliac disease by biopsy. Sensitivity was 65.1% (50.2% to 77.6%) and specificity was 100% (99.8% to 100%) compared with combined results of IgA and IgG laboratory tests. Trained laboratory workers detected 30 of the 31 newly diagnosed IgA competent patients with the rapid test kit used blindly. Median time to biopsy after a positive rapid test result was significantly shorter (20 days, range 4-148) than after a positive laboratory result (142 days, 70-256; P<0.001). Children with coeliac disease detected at screening were smaller and had worse health status than their peers but they improved on a gluten-free diet. Conclusions A simple rapid antibody test enabled primary care nurses to detect patients with coeliac disease in the community who were not picked up in clinical care. Extra training is needed to improve sensitivity. PMID:18063612

  11. GMOseek: a user friendly tool for optimized GMO testing.

    PubMed

    Morisset, Dany; Novak, Petra Kralj; Zupanič, Darko; Gruden, Kristina; Lavrač, Nada; Žel, Jana

    2014-08-01

    With the increasing pace of new Genetically Modified Organisms (GMOs) authorized or in pipeline for commercialization worldwide, the task of the laboratories in charge to test the compliance of food, feed or seed samples with their relevant regulations became difficult and costly. Many of them have already adopted the so called "matrix approach" to rationalize the resources and efforts used to increase their efficiency within a limited budget. Most of the time, the "matrix approach" is implemented using limited information and some proprietary (if any) computational tool to efficiently use the available data. The developed GMOseek software is designed to support decision making in all the phases of routine GMO laboratory testing, including the interpretation of wet-lab results. The tool makes use of a tabulated matrix of GM events and their genetic elements, of the laboratory analysis history and the available information about the sample at hand. The tool uses an optimization approach to suggest the most suited screening assays for the given sample. The practical GMOseek user interface allows the user to customize the search for a cost-efficient combination of screening assays to be employed on a given sample. It further guides the user to select appropriate analyses to determine the presence of individual GM events in the analyzed sample, and it helps taking a final decision regarding the GMO composition in the sample. GMOseek can also be used to evaluate new, previously unused GMO screening targets and to estimate the profitability of developing new GMO screening methods. The presented freely available software tool offers the GMO testing laboratories the possibility to select combinations of assays (e.g. quantitative real-time PCR tests) needed for their task, by allowing the expert to express his/her preferences in terms of multiplexing and cost. The utility of GMOseek is exemplified by analyzing selected food, feed and seed samples from a national reference laboratory for GMO testing and by comparing its performance to existing tools which use the matrix approach. GMOseek proves superior when tested on real samples in terms of GMO coverage and cost efficiency of its screening strategies, including its capacity of simple interpretation of the testing results.

  12. A pilot study of a simple screening technique for estimation of salivary flow.

    PubMed

    Kanehira, Takashi; Yamaguchi, Tomotaka; Takehara, Junji; Kashiwazaki, Haruhiko; Abe, Takae; Morita, Manabu; Asano, Kouzo; Fujii, Yoshinori; Sakamoto, Wataru

    2009-09-01

    The purpose of this study was to develop a simple screening technique for estimation of salivary flow and to test the usefulness of the method for determining decreased salivary flow. A novel assay system comprising 3 spots containing 30 microg starch and 49.6 microg potassium iodide per spot on filter paper and a coloring reagent, based on the color reaction of iodine-starch and theory of paper chromatography, was designed. We investigated the relationship between resting whole salivary rates and the number of colored spots on the filter produced by 41 hospitalized subjects. A significant negative correlation was observed between the number of colored spots and the resting salivary flow rate (n = 41; r = -0.803; P < .01). For all complaints of decreased salivary flow (n = 9) having cutoff values <100 microL/min for the salivary flow rate, 3 colored spots appeared on the paper, whereas for healthy subjects there was < or =1 colored spot. This novel assay system might be effective for estimation of salivary flow not only in healthy but also in bedridden and disabled elderly people.

  13. [Cervical cancer screening: past--present--future].

    PubMed

    Breitenecker, G

    2009-12-01

    Despite the undisputed and impressive success which has been achieved since the 1960s by cervical cytology in the fight against cervical cancer and its precursor stages, during which the mortality rate in industrialized countries over the last 40 years has been reduced by two-thirds to three-quarters, a perfect and error-free screening procedure is still a long way off and will probably never be reached. There are two main reasons for this, the lack of adequate coverage and suboptimal quality and assessment of smears. Two screening procedures are in use Europe, an opportunistic and an organized system. Both systems have many advantages but also disadvantages. In organized programs the coverage is higher (up to 80%), although similar numbers are also achieved by non-organized programs over a 3-year cycle, even if they cannot be so exactly documented. The decision on which system is used depends on the health system of the country, public or non-public, and many other national circumstances. However, in both systems prerequisites for a satisfactory result is a high quality in the sampling technique, the processing and the assessment. Therefore, several guidelines have been introduced by state and medical societies for internal and external quality assurance. New technologies, such as thin-layer cytology or automation for replacement or support of conventional cytology liquid-based cytology proved not to be superior enough to justify the high costs of these systems. The recognition of the strong causal relationship between persistent infection with high-risk human papillomavirus (HPV) types and cervical cancer and its precursors has resulted in the development of comparably simple tests. Primary screening using HPV typing alone is not recommended in opportunistic screening due to the low specificity but high sensitivity because it leads to many clinically irrelevant results which place women under stress. In organized screening HPV testing is always and only possible in combination with cytology. Various models and approaches are in the testing phase and appear promising. HPV testing is on the other hand well accepted and recommended as a triage test to select women with equivocal smear results (Pap group III, ASCUS) if a biopsy is required or can be followed up and also for follow-up of patients after cone biopsy. However, vaccination of young girls against oncogenic HPV types which has now become widespread still leaves many questions open for the future because the observation period is too short. There is justified hope that this will become a valuable tool in cervical cancer control and may lead to a substantial reduction in the burden of cervical cancer in the future. However, as the current vaccines on the market do not cover all oncogenic virus types and the effects of vaccination will only be observed after many years, the necessity of a cytological screening will remain unrestricted. Therefore, cervical cytology will remain as the trusted, simple to use, economic and proven, like no other method for early cancer detection, efficient procedure even in the foreseeable future. If carried out with the highest quality demands it will play a central role in the early detection of cervical cancer.

  14. Power of automated algorithms for combining time-line follow-back and urine drug screening test results in stimulant-abuse clinical trials.

    PubMed

    Oden, Neal L; VanVeldhuisen, Paul C; Wakim, Paul G; Trivedi, Madhukar H; Somoza, Eugene; Lewis, Daniel

    2011-09-01

    In clinical trials of treatment for stimulant abuse, researchers commonly record both Time-Line Follow-Back (TLFB) self-reports and urine drug screen (UDS) results. To compare the power of self-report, qualitative (use vs. no use) UDS assessment, and various algorithms to generate self-report-UDS composite measures to detect treatment differences via t-test in simulated clinical trial data. We performed Monte Carlo simulations patterned in part on real data to model self-report reliability, UDS errors, dropout, informatively missing UDS reports, incomplete adherence to a urine donation schedule, temporal correlation of drug use, number of days in the study period, number of patients per arm, and distribution of drug-use probabilities. Investigated algorithms include maximum likelihood and Bayesian estimates, self-report alone, UDS alone, and several simple modifications of self-report (referred to here as ELCON algorithms) which eliminate perceived contradictions between it and UDS. Among the algorithms investigated, simple ELCON algorithms gave rise to the most powerful t-tests to detect mean group differences in stimulant drug use. Further investigation is needed to determine if simple, naïve procedures such as the ELCON algorithms are optimal for comparing clinical study treatment arms. But researchers who currently require an automated algorithm in scenarios similar to those simulated for combining TLFB and UDS to test group differences in stimulant use should consider one of the ELCON algorithms. This analysis continues a line of inquiry which could determine how best to measure outpatient stimulant use in clinical trials (NIDA. NIDA Monograph-57: Self-Report Methods of Estimating Drug Abuse: Meeting Current Challenges to Validity. NTIS PB 88248083. Bethesda, MD: National Institutes of Health, 1985; NIDA. NIDA Research Monograph 73: Urine Testing for Drugs of Abuse. NTIS PB 89151971. Bethesda, MD: National Institutes of Health, 1987; NIDA. NIDA Research Monograph 167: The Validity of Self-Reported Drug Use: Improving the Accuracy of Survey Estimates. NTIS PB 97175889. GPO 017-024-01607-1. Bethesda, MD: National Institutes of Health, 1997).

  15. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    PubMed

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  16. Simple animal models for amyotrophic lateral sclerosis drug discovery.

    PubMed

    Patten, Shunmoogum A; Parker, J Alex; Wen, Xiao-Yan; Drapeau, Pierre

    2016-08-01

    Simple animal models have enabled great progress in uncovering the disease mechanisms of amyotrophic lateral sclerosis (ALS) and are helping in the selection of therapeutic compounds through chemical genetic approaches. Within this article, the authors provide a concise overview of simple model organisms, C. elegans, Drosophila and zebrafish, which have been employed to study ALS and discuss their value to ALS drug discovery. In particular, the authors focus on innovative chemical screens that have established simple organisms as important models for ALS drug discovery. There are several advantages of using simple animal model organisms to accelerate drug discovery for ALS. It is the authors' particular belief that the amenability of simple animal models to various genetic manipulations, the availability of a wide range of transgenic strains for labelling motoneurons and other cell types, combined with live imaging and chemical screens should allow for new detailed studies elucidating early pathological processes in ALS and subsequent drug and target discovery.

  17. Normal Variability of Weekly Musculoskeletal Screening Scores and the Influence of Training Load across an Australian Football League Season.

    PubMed

    Esmaeili, Alireza; Stewart, Andrew M; Hopkins, William G; Elias, George P; Lazarus, Brendan H; Rowell, Amber E; Aughey, Robert J

    2018-01-01

    Aim: The sit and reach test (S&R), dorsiflexion lunge test (DLT), and adductor squeeze test (AST) are commonly used in weekly musculoskeletal screening for athlete monitoring and injury prevention purposes. The aim of this study was to determine the normal week to week variability of the test scores, individual differences in variability, and the effects of training load on the scores. Methods: Forty-four elite Australian rules footballers from one club completed the weekly screening tests on day 2 or 3 post-main training (pre-season) or post-match (in-season) over a 10 month season. Ratings of perceived exertion and session duration for all training sessions were used to derive various measures of training load via both simple summations and exponentially weighted moving averages. Data were analyzed via linear and quadratic mixed modeling and interpreted using magnitude-based inference. Results: Substantial small to moderate variability was found for the tests at both season phases; for example over the in-season, the normal variability ±90% confidence limits were as follows: S&R ±1.01 cm, ±0.12; DLT ±0.48 cm, ±0.06; AST ±7.4%, ±0.6%. Small individual differences in variability existed for the S&R and AST (factor standard deviations between 1.31 and 1.66). All measures of training load had trivial effects on the screening scores. Conclusion: A change in a test score larger than the normal variability is required to be considered a true change. Athlete monitoring and flagging systems need to account for the individual differences in variability. The tests are not sensitive to internal training load when conducted 2 or 3 days post-training or post-match, and the scores should be interpreted cautiously when used as measures of recovery.

  18. Routine screening for α-thalassaemia using an immunochromatographic strip assay for haemoglobin Bart's.

    PubMed

    Prayalaw, Patcharawadee; Fucharoen, Goonnapa; Fucharoen, Supan

    2014-09-01

    To evaluate an immunochromatographic (IC) strip assay for Hb Bart's as a routine screening test for α-thalassaemia in area with a high prevalence of thalassaemia and haemoglobinopathies. A total of 300 adult screen positive blood specimens were collected at an ongoing thalassaemia screening programme in northeast Thailand. Routine screening was done using red blood cell indices, osmotic fragility, and dichlorophenolindophenol tests. The IC strip assay for haemoglobin Bart's was performed on all samples. The result was evaluated against thalassaemia genotypes determined using standard haemoglobin and DNA analyses. Of 300 subjects investigated, Hb and DNA analyses identified 32 with normal genotype. The remaining subjects carried thalassaemia with as many as 16 different genotypes. Hb Bart's was detected in all cases, with several α(0)-thalassaemia (SEA type) related disorders. Of cases with α(+)-thalassaemia, 86.1% showed a positive result; 100 out of 103 Hb E carriers, all homozygous Hb E and β-thalassaemia trait were negative. Nine out of 17 cases with β-thalassaemia/Hb E disease, and one case of double heterozygote for Hb Q-Thailand and Hb E returned positive results. The overall sensitivity and specificity of the IC strip assay for detecting α(0)-thalassaemia were 100% and 73.1%, respectively. The results showed a high sensitivity for screening for α(0)-thalassaemia using IC strip assay for Hb Bart's. This simple method, used in combination with conventional screening protocols, should lead to a significant reduction in the number of referral cases for DNA analysis. Cost effectiveness in each population should be taken into consideration. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Comparative evaluation of monocular augmented-reality display for surgical microscopes.

    PubMed

    Rodriguez Palma, Santiago; Becker, Brian C; Lobes, Louis A; Riviere, Cameron N

    2012-01-01

    Medical augmented reality has undergone much development recently. However, there is a lack of studies quantitatively comparing the different display options available. This paper compares the effects of different graphical overlay systems in a simple micromanipulation task with "soft" visual servoing. We compared positioning accuracy in a real-time visually-guided task using Micron, an active handheld tremor-canceling microsurgical instrument, using three different displays: 2D screen, 3D screen, and microscope with monocular image injection. Tested with novices and an experienced vitreoretinal surgeon, display of virtual cues in the microscope via an augmented reality injection system significantly decreased 3D error (p < 0.05) compared to the 2D and 3D monitors when confounding factors such as magnification level were normalized.

  20. Novel method for quantitative ANA measurement using near-infrared imaging.

    PubMed

    Peterson, Lisa K; Wells, Daniel; Shaw, Laura; Velez, Maria-Gabriela; Harbeck, Ronald; Dragone, Leonard L

    2009-09-30

    Antinuclear antibodies (ANA) have been detected in patients with systemic rheumatic diseases and are used in the screening and/or diagnosis of autoimmunity in patients as well as mouse models of systemic autoimmunity. Indirect immunofluorescence (IIF) on HEp-2 cells is the gold standard for ANA screening. However, its usefulness is limited in diagnosis, prognosis and monitoring of disease activity due to the lack of standardization in performing the technique, subjectivity in interpreting the results and the fact that it is only semi-quantitative. Various immunological techniques have been developed in an attempt to improve upon the method to quantify ANA, including enzyme-linked immunosorbent assays (ELISAs), line immunoassays (LIAs), multiplexed bead immunoassays and IIF on substrates other than HEp-2 cells. Yet IIF on HEp-2 cells remains the most common screening method for ANA. In this study, we describe a simple quantitative method to detect ANA which combines IIF on HEp-2 coated slides with analysis using a near-infrared imaging (NII) system. Using NII to determine ANA titer, 86.5% (32 of 37) of the titers for human patient samples were within 2 dilutions of those determined by IIF, which is the acceptable range for proficiency testing. Combining an initial screening for nuclear staining using microscopy with titration by NII resulted in 97.3% (36 of 37) of the titers detected to be within two dilutions of those determined by IIF. The NII method for quantitative ANA measurements using serum from both patients and mice with autoimmunity provides a fast, relatively simple, objective, sensitive and reproducible assay, which could easily be standardized for comparison between laboratories.

  1. Video instrumentation for radionuclide angiocardiography.

    NASA Technical Reports Server (NTRS)

    Kriss, J. P.

    1973-01-01

    Two types of videoscintiscopes for performing radioisotopic angiocardiography with a scintillation camera are described, and use of these instruments in performing clinical studies is illustrated. Radionuclide angiocardiography is a simple, quick and accurate procedure recommended as a screening test for patients with a variety of congenital and acquired cardiovascular lesions. When performed in conjunction with coronary arterial catheterization, dynamic radionuclide angiography may provide useful information about regional myocardial perfusion. Quantitative capabilities greatly enhance the potential of this diagnostic tool.

  2. Waist-to-Height Ratio: a simple, effective and practical screening tool for childhood obesity and metabolic syndrome.

    PubMed

    Zhou, Dan; Yang, Min; Yuan, Zhe-Ping; Zhang, Dan-Dan; Liang, Li; Wang, Chun-Lin; Zhang, Shuai; Zhu, Hong-Hong; Lai, Mao-De; Zhu, Yi-Min

    2014-10-01

    This study aimed to evaluate the diagnostic value of Waist-to-Height Ratio in early detection of obesity and metabolic syndrome in Chinese children and adolescents. A cross-sectional study was conducted in six cities in China in 2010 with 16,914 children and adolescents aged 7-17 years. Participants were randomly divided into the training and testing sets. Diagnostic values were estimated using sensitivity, specificity and areas under receiver operating characteristic curves. The coefficients of variation of Waist-to-Height Ratio among age groups were lower than that of body mass index and waist circumstance. The area under receiver operating characteristic curve of Waist-to-Height Ratio was 0.968 in boys and 0.949 in girls for general obesity evaluation, and 0.983 in boys and 0.984 in girls for central obesity. The optimal cut-offs of Waist-to-Height Ratio were 0.47 in boys and 0.45 in girls in the training set and validated in the testing set. For metabolic syndrome evaluation, the sensitivity and specificity were 0.858 and 0.825 in boys, 0.864 and 0.812 in girls under the suggested cut-offs. Waist-to-Height Ratio was a simple, effective and practical tool for mass screening childhood obesity and metabolic syndrome in China. It will have potential values in public health practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Pyrosequencing-based validation of a simple cell-suspension polymerase chain reaction assay for Campylobacter with application of high-processivity polymerase and novel internal amplification controls for rapid and specific detection.

    PubMed

    Oakley, Brian B; Line, J Eric; Berrang, Mark E; Johnson, Jessica M; Buhr, R Jeff; Cox, Nelson A; Hiett, Kelli L; Seal, Bruce S

    2012-02-01

    Although Campylobacter is an important food-borne human pathogen, there remains a lack of molecular diagnostic assays that are simple to use, cost-effective, and provide rapid results in research, clinical, or regulatory laboratories. Of the numerous Campylobacter assays that do exist, to our knowledge none has been empirically tested for specificity using high-throughput sequencing. Here we demonstrate the power of next-generation sequencing to determine the specificity of a widely cited Campylobacter-specific polymerase chain reaction (PCR) assay and describe a rapid method for direct cell suspension PCR to quickly and easily screen samples for Campylobacter. We present a specific protocol which eliminates the need for time-consuming and expensive genomic DNA extractions and, using a high-processivity polymerase, demonstrate conclusive screening of samples in <1 h. Pyrosequencing results show the assay to be extremely (>99%) sensitive, and spike-back experiments demonstrated a detection threshold of <10(2) CFU mL(-1). Additionally, we present 2 newly designed broad-range bacterial primer sets targeting the 23S rRNA gene that have wide applicability as internal amplification controls. Empirical testing of putative taxon-specific assays using high-throughput sequencing is an important validation step that is now financially feasible for research, regulatory, or clinical applications. Published by Elsevier Inc.

  4. Design of and normative data for a new computer based test of ocular torsion.

    PubMed

    Vaswani, Reena S; Mudgil, Ananth V

    2004-01-01

    To evaluate a new clinically practical and dynamic test for quantifying torsional binocular eye alignment changes which may occur in the change from monocular to binocular viewing conditions. The test was developed using a computer with Lotus Freelance Software, binoculars with prisms and colored filters. The subject looks through binoculars at the computer screen two meters away. For monocular vision, six concentric blue circles, a blue horizontal line and a tilted red line were displayed on the screen. For binocular vision, white circles replaced blue circles. The subject was asked to orient the lines parallel to each other. The difference in tilt (degrees) between the subjective parallel and fixed horizontal position is the torsional alignment of the eye. The time to administer the test was approximately two minutes. In 70 Normal subjects, average age 16 years, the mean degree of cyclodeviation tilt in the right eye was 0.6 degrees for monocular viewing conditions and 0.7 degrees for binocular viewing conditions, with a standard deviation of approximately one degree. There was no "statistically significant" difference between monocular and binocular viewing. This computer based test is a simple, computerized, non-invasive test that has a potential for use in the diagnosis of cyclovertical strabismus. Currently, there is no commercially available test for this purpose.

  5. A founder large deletion mutation in Xeroderma pigmentosum-Variant form in Tunisia: implication for molecular diagnosis and therapy.

    PubMed

    Ben Rekaya, Mariem; Laroussi, Nadia; Messaoud, Olfa; Jones, Mariem; Jerbi, Manel; Naouali, Chokri; Bouyacoub, Yosra; Chargui, Mariem; Kefi, Rym; Fazaa, Becima; Boubaker, Mohamed Samir; Boussen, Hamouda; Mokni, Mourad; Abdelhak, Sonia; Zghal, Mohamed; Khaled, Aida; Yacoub-Youssef, Houda

    2014-01-01

    Xeroderma pigmentosum Variant (XP-V) form is characterized by a late onset of skin symptoms. Our aim is the clinical and genetic investigations of XP-V Tunisian patients in order to develop a simple tool for early diagnosis. We investigated 16 suspected XP patients belonging to ten consanguineous families. Analysis of the POLH gene was performed by linkage analysis, long range PCR, and sequencing. Genetic analysis showed linkage to the POLH gene with a founder haplotype in all affected patients. Long range PCR of exon 9 to exon 11 showed a 3926 bp deletion compared to control individuals. Sequence analysis demonstrates that this deletion has occurred between two Alu-Sq2 repetitive sequences in the same orientation, respectively, in introns 9 and 10. We suggest that this mutation POLH NG_009252.1: g.36847_40771del3925 is caused by an equal crossover event that occurred between two homologous chromosomes at meiosis. These results allowed us to develop a simple test based on a simple PCR in order to screen suspected XP-V patients. In Tunisia, the prevalence of XP-V group seems to be underestimated and clinical diagnosis is usually later. Cascade screening of this founder mutation by PCR in regions with high frequency of XP provides a rapid and cost-effective tool for early diagnosis of XP-V in Tunisia and North Africa.

  6. A Founder Large Deletion Mutation in Xeroderma Pigmentosum-Variant Form in Tunisia: Implication for Molecular Diagnosis and Therapy

    PubMed Central

    Ben Rekaya, Mariem; Laroussi, Nadia; Messaoud, Olfa; Jones, Mariem; Jerbi, Manel; Bouyacoub, Yosra; Chargui, Mariem; Kefi, Rym; Fazaa, Becima; Boubaker, Mohamed Samir; Boussen, Hamouda; Mokni, Mourad; Abdelhak, Sonia; Zghal, Mohamed; Khaled, Aida; Yacoub-Youssef, Houda

    2014-01-01

    Xeroderma pigmentosum Variant (XP-V) form is characterized by a late onset of skin symptoms. Our aim is the clinical and genetic investigations of XP-V Tunisian patients in order to develop a simple tool for early diagnosis. We investigated 16 suspected XP patients belonging to ten consanguineous families. Analysis of the POLH gene was performed by linkage analysis, long range PCR, and sequencing. Genetic analysis showed linkage to the POLH gene with a founder haplotype in all affected patients. Long range PCR of exon 9 to exon 11 showed a 3926 bp deletion compared to control individuals. Sequence analysis demonstrates that this deletion has occurred between two Alu-Sq2 repetitive sequences in the same orientation, respectively, in introns 9 and 10. We suggest that this mutation POLH NG_009252.1: g.36847_40771del3925 is caused by an equal crossover event that occurred between two homologous chromosomes at meiosis. These results allowed us to develop a simple test based on a simple PCR in order to screen suspected XP-V patients. In Tunisia, the prevalence of XP-V group seems to be underestimated and clinical diagnosis is usually later. Cascade screening of this founder mutation by PCR in regions with high frequency of XP provides a rapid and cost-effective tool for early diagnosis of XP-V in Tunisia and North Africa. PMID:24877075

  7. Could CT screening for lung cancer ever be cost effective in the United Kingdom?

    PubMed Central

    Whynes, David K

    2008-01-01

    Background The absence of trial evidence makes it impossible to determine whether or not mass screening for lung cancer would be cost effective and, indeed, whether a clinical trial to investigate the problem would be justified. Attempts have been made to resolve this issue by modelling, although the complex models developed to date have required more real-world data than are currently available. Being founded on unsubstantiated assumptions, they have produced estimates with wide confidence intervals and of uncertain relevance to the United Kingdom. Method I develop a simple, deterministic, model of a screening regimen potentially applicable to the UK. The model includes only a limited number of parameters, for the majority of which, values have already been established in non-trial settings. The component costs of screening are derived from government guidance and from published audits, whilst the values for test parameters are derived from clinical studies. The expected health gains as a result of screening are calculated by combining published survival data for screened and unscreened cohorts with data from Life Tables. When a degree of uncertainty over a parameter value exists, I use a conservative estimate, i.e. one likely to make screening appear less, rather than more, cost effective. Results The incremental cost effectiveness ratio of a single screen amongst a high-risk male population is calculated to be around £14,000 per quality-adjusted life year gained. The average cost of this screening regimen per person screened is around £200. It is possible that, when obtained experimentally in any future trial, parameter values will be found to differ from those previously obtained in non-trial settings. On the basis both of differing assumptions about evaluation conventions and of reasoned speculations as to how test parameters and costs might behave under screening, the model generates cost effectiveness ratios as high as around £20,000 and as low as around £7,000. Conclusion It is evident that eventually being able to identify a cost effective regimen of CT screening for lung cancer in the UK is by no means an unreasonable expectation. PMID:18302756

  8. Posture Alignment of Adolescent Idiopathic Scoliosis: Photogrammetry in Scoliosis School Screening.

    PubMed

    Penha, Patrícia Jundi; Penha, Nárima Lívia Jundi; De Carvalho, Bárbarah Kelly Gonçalves; Andrade, Rodrigo Mantelatto; Schmitt, Ana Carolina Basso; João, Sílvia Maria Amado

    The objective of this study was to describe the posture patterns of adolescents diagnosed with adolescent idiopathic scoliosis (AIS) in a scoliosis school screening (SSS). Two-dimensional photogrammetry was used to assess the posture of 37 adolescents diagnosed with scoliosis (scoliosis group, SG) (Cobb angle ≥10°) and 76 adolescents with a false positive diagnosis (false positive group, FPG) (Cobb angle <10°, angle of trunk rotation ≥7°). In total, 2562 10- to 14-year-old adolescents were enrolled in the SSS, which was performed in public schools in the cities of Amparo, Pedreira, and Mogi Mirim in the state of São Paulo, Brazil. Their posture was analyzed using Postural Analysis Software. Continuous variables were tested using Student t test, and categorical variables were tested using a χ2 test. The SG, FPG, simple curve group, and double curve group were all compared. Bivariate analysis was used to identify associations between postural deviations and scoliosis. The adopted significance level was α = .05. The SG (2.7 ± 1.9°) had greater shoulder obliquity than the FPG (1.9 ± 1.4°) (P = .010), and this deviation was associated with scoliosis (odds ratio [95% CI] P = 1.4 [1.1-1.8] 0.011). The SG had asymmetry between the right- and left-side lower limb frontal angle, shoulder sagittal alignment, and knee angle. The double curve group (3 ± 1.7°) presented a greater value of the vertical alignment of the torso than the simple curve group did (1.9 ± 1°; P = .032). Adolescents diagnosed with AIS in an SSS had greater shoulder obliquity and asymmetry between the right and left sides. Shoulder obliquity was the only postural deviation associated with AIS. Copyright © 2017. Published by Elsevier Inc.

  9. Materials selection for long life in LEO: A critical evaluation of atomic oxygen testing with thermal atom systems

    NASA Technical Reports Server (NTRS)

    Koontz, S. L.; Kuminecz, J.; Leger, L.; Nordine, P.

    1988-01-01

    The use of thermal atom test methods as a materials selection and screening technique for low-Earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined to be in thermal atom environments are compared to those observed in LEO and in high quality LEO simulations. Reaction efficiencies measured in a new type of thermal atom apparatus are one-hundredth to one-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of 8 in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain specific thermal test environments can be used as reliable materials screening tools. Using thermal atom methods to predict material lifetime in LEO requires direct calibration of the method against LEO data or high quality simulation data for each material.

  10. A Danish diabetes risk score for targeted screening: the Inter99 study.

    PubMed

    Glümer, Charlotte; Carstensen, Bendix; Sandbaek, Annelli; Lauritzen, Torsten; Jørgensen, Torben; Borch-Johnsen, Knut

    2004-03-01

    To develop a simple self-administered questionnaire identifying individuals with undiagnosed diabetes with a sensitivity of 75% and minimizing the high-risk group needing subsequent testing. A population-based sample (Inter99 study) of 6,784 individuals aged 30-60 years completed a questionnaire on diabetes-related symptoms and risk factors. The participants underwent an oral glucose tolerance test. The risk score was derived from the first half and validated on the second half of the study population. External validation was performed based on the Danish Anglo-Danish-Dutch Study of Intensive Treatment in People with Screen Detected Diabetes in Primary Care (ADDITION) pilot study. The risk score was developed by stepwise backward multiple logistic regression. The final risk score included age, sex, BMI, known hypertension, physical activity at leisure time, and family history of diabetes, items independently and significantly (P<0.05) associated with the presence of previously undiagnosed diabetes. The area under the receiver operating curve was 0.804 (95% CI 0.765-0.838) for the first half of the Inter99 population, 0.761 (0.720-0.803) for the second half of the Inter99 population, and 0.803 (0.721-0.876) for the ADDITION pilot study. The sensitivity, specificity, and percentage that needed subsequent testing were 76, 72, and 29%, respectively. The false-negative individuals in the risk score had a lower absolute risk of ischemic heart disease compared with the true-positive individuals (11.3 vs. 20.4%; P<0.0001). We developed a questionnaire to be used in a stepwise screening strategy for type 2 diabetes, decreasing the numbers of subsequent tests and thereby possibly minimizing the economical and personal costs of the screening strategy.

  11. Biological Concerns on the Selection of Animal Models for Teratogenic Testing.

    PubMed

    Alves-Pimenta, Sofia; Colaço, Bruno; Oliveira, Paula A; Venâncio, Carlos

    2018-01-01

    During pregnancy fetus can be exposed to a variety of chemicals which may induce abortion and malformations. Due to the amounts of new substances coming into the market every year, a high demand for a rapid, reliable, and cost-effective method to detect potential toxicity is necessary. Different species have been used as animal models for teratogen screening, most of them sharing similar development processes with humans. However, the application of embryology knowledge to teratology is hampered by the complexity of the reproduction processes.The present chapter outlines the essential development periods in different models, and highlights the similarities and differences between species, advantages and disadvantages of each group, and specific sensitivities for teratogenic tests. These models can be organized into the following categories: (1) invertebrate species such Caenorhabditis elegans and Drosophila melanogaster, which have become ideal for screening simple mechanisms in the early periods of reproductive cycle, allowing for rapid results and minor ethical concerns; (2) vertebrate nonmammalian species such Xenopus laevis and Danio rerio, important models to assess teratogenic potential in later development with fewer ethical requirements; and (3) the mammalian species Mus musculus, Rattus norvegicus, and Oryctolagus cuniculus, phylogenetically more close to humans, essential to assess complex specialized processes, that occur later in development.Rules for development toxicology tests require the use of mammalian species. However, ethical concerns and costs limit their use in large-scale screening. By contrast, invertebrate and vertebrate nonmammalian species are increasing as alternative animal models, as these organisms combine less ethical requirements, low costs and culture conditions compatible with large-scale screening. In contrast to the in vitro techniques, their main advantage is to allow for high-throughput screening in a whole-animal context, not dependent on the prior identification of a target. In this chapter, the biological development of the animals most used in teratogenic tests is adressed with the aims of maximizing human translation, reducing the number of animals used, and the time to market for new drugs.

  12. The influence of two different invitation letters on Chlamydia testing participation: randomized controlled trial.

    PubMed

    Ten Hoor, Gill; Hoebe, Christian Jpa; van Bergen, Jan Eam; Brouwers, Elfi Ehg; Ruiter, Robert Ac; Kok, Gerjo

    2014-01-30

    In The Netherlands, screening for chlamydia (the most prevalent sexually transmitted infection worldwide) is a relatively simple and free procedure. Via an invitation letter sent by the public health services (PHS), people are asked to visit a website to request a test kit. They can then do a chlamydia test at home, send it anonymously to a laboratory, and, within two weeks, they can review their test results online and be treated by their general practitioner or the PHS. Unfortunately, the participation rates are low and the process is believed to be not (cost-) effective. The objective of this study was to assess whether the low participation rate of screening for chlamydia at home, via an invitation letter asking to visit a website and request a test kit, could be improved by optimizing the invitation letter through systematically applied behavior change theories and evidence. The original letter and a revised letter were randomly sent out to 13,551 citizens, 16 to 29 years old, in a Dutch municipality. Using behavior change theories, the revised letter sought to increase motivation to conduct chlamydia screening tests. The revised letter was tailored to beliefs that were found in earlier studies: risk perception, advantages and disadvantages (attitude), moral norm, social influence, and response- and self-efficacy. Revisions to the new letter also sought to avoid possible unwanted resistance caused when people feel pressured, and included prompts to trigger the desired behavior. No significant differences in test package requests were found between the two letters. There were also no differences between the original and revised letters in the rates of returned tests (11.80%, 581/4922 vs. 11.07%, 549/4961) or positive test results (4.8%, 23/484 vs. 4.1%, 19/460). It is evident that the new letter did not improve participation compared to the original letter. It is clear that the approach of inviting the target population through a letter does not lead to higher participation rates for chlamydia screening. Other approaches have to be developed and pilot tested.

  13. Wink, wink, nudge, nudge... maybe we need more than incentives to get us moving.

    PubMed

    Ellen, Moriah; Shamian, Judith

    2012-01-01

    In the lead essay, Oliver differentiates between utilizing incentives to motivate single simple behaviour changes (e.g., getting immunizations, undergoing screening tests) and using them to motivate sustained behaviour changes (e.g., losing weight, quitting smoking). This commentary focuses on the latter. Here, the authors talk about four main points related to the lead article: (1) governmental intervention, (2) understanding why people do not change their behaviour, (3) contemplating motivational "nudges" other than money and (4) other policy considerations.

  14. Predischarge screening for chronic obstructive pulmonary disease in patients with acute coronary syndrome and smoking history.

    PubMed

    Campo, Gianluca; Pavasini, Rita; Barbetta, Carlo; Maietti, Elisa; Mascetti, Susanna; Biscaglia, Simone; Zaraket, Fatima; Spitaleri, Giosafat; Gallo, Francesco; Tonet, Elisabetta; Papi, Alberto; Ferrari, Roberto; Contoli, Marco

    2016-11-01

    Several studies suggested that chronic obstructive pulmonary disease (COPD) is largely underdiagnosed in patients with acute coronary syndrome (ACS) contributing to further affect clinical outcome. Our aim was to validate a screening procedure to identify, in ACS patients, those with negligible risk of undiagnosed COPD. From December 2014 to August 2015, 169 ACS patients with smoking history underwent screening procedure. Screening procedure combined peak expiratory flow rate (PEFR, defined as positive if <80% of predicted) and respiratory health status questionnaire (RHSQ, defined as positive if >19.5 points). The screening was considered negative if both tests provided negative results, positive if both were positive, uncertain in presence of discrepancy. Spirometry was planned after 2months to identify or not the presence of irreversible airflow obstruction (undiagnosed COPD). The primary endpoint was the negative predictive value of screening for undiagnosed COPD. Overall, 137 (81%) patients received spirometry (final study population). Screening was negative, uncertain and positive in 58 (42%), 46 (34%) and 33 (24%) patients, respectively. We found undiagnosed COPD in 39 (29%) patients. Only 3 patients with negative screening showed undiagnosed COPD. Negative screening showed the best ability to discriminate patients without COPD (negative predictive value 95%). Two-month health status in patients with undiagnosed COPD was significantly poor. Undiagnosed COPD is relatively frequent in ACS patients with smoking history and a simple screening procedure including PEFR and RHSQ can be administered before hospital discharge to discriminate those at negligible risk of undiagnosed COPD (ClinicalTrials.gov, NCT02324660). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Screening of female family members of von Willebrand disease patients: utility of a modified screening tool in a high-risk population.

    PubMed

    Faiz, A S; Kaveney, A; Guo, S; Murphy, S; Philipp, C S

    2017-09-01

    Family members of Von Willebrand disease (VWD) patients may have low levels of VWF without major bleeding episodes and often remain undiagnosed. The purpose of this study was to assess the utility of a modified Screening Tool in identifying previously untested reproductive age female family members of VWD patients for haemostatic evaluation. Ninety-four reproductive age women including 41 previously untested family members of VWD patients, 26 previously diagnosed VWD patients and 27 healthy controls were administered a modified Screening Tool and had blood drawn for CBC, ferritin, and VWF testing. Participants completed a pictorial blood assessment chart (PBAC) with menses. The modified Screening Tool was positive in 32% family members, 77% VWD patients, and 19% controls (P < 0.001). Combined with low ferritin, the modified Screening Tool was positive in 66% family members, 92% VWD patients, and 44% controls (P = 0.001). In family members, incorporating low ferritin with the modified Screening Tool resulted in a sensitivity of 86% (95% CI, 42-100) and negative predictive value of 93% (95% CI, 66-100). In the control group, NPV was between 92% and 95% for the modified Screening Tool and also for the modified Screening Tool combined with low ferritin or a positive PBAC. These data in a racially diverse population suggest the usefulness of a simple, easy to administer modified Screening Tool. In conjunction with ferritin it could be used in a primary care setting to stratify reproductive age women with a family history of VWD for haemostatic evaluation. © 2017 John Wiley & Sons Ltd.

  16. Mobility Lab to Assess Balance and Gait with Synchronized Body-worn Sensors

    PubMed Central

    Mancini, Martina; King, Laurie; Salarian, Arash; Holmstrom, Lars; McNames, James; Horak, Fay B

    2014-01-01

    This paper is a commentary to introduce how rehabilitation professionals can use a new, body-worn sensor system to obtain objective measures of balance and gait. Current assessments of balance and gait in clinical rehabilitation are largely limited to subjective scales, simple stop-watch measures, or complex, expensive machines not practical or largely available. Although accelerometers and gyroscopes have been shown to accurately quantify many aspects of gait and balance kinematics, only recently a comprehensive, portable system has become available for clinicians. By measuring body motion during tests that clinicians are already performing, such as the Timed Up and Go test (TUG) and the Clinical Test of Sensory Integration for Balance (CITSIB), the additional time for assessment is minimal. By providing instant analysis of balance and gait and comparing a patient’s performance to age-matched control values, therapists receive an objective, sensitive screening profile of balance and gait strategies. This motion screening profile can be used to identify mild abnormalities not obvious with traditional clinical testing, measure small changes due to rehabilitation, and design customized rehabilitation programs for each individual’s specific balance and gait deficits. PMID:24955286

  17. The zebrafish world of colors and shapes: preference and discrimination.

    PubMed

    Oliveira, Jessica; Silveira, Mayara; Chacon, Diana; Luchiari, Ana

    2015-04-01

    Natural environment imposes many challenges to animals, which have to use cognitive abilities to cope with and exploit it to enhance their fitness. Since zebrafish is a well-established model for cognitive studies and high-throughput screening for drugs and diseases that affect cognition, we tested their ability for ambient color preference and 3D objects discrimination to establish a protocol for memory evaluation. For the color preference test, zebrafish were observed in a multiple-chamber tank with different environmental color options. Zebrafish showed preference for blue and green, and avoided yellow and red. For the 3D objects discrimination, zebrafish were allowed to explore two equal objects and then observed in a one-trial test in which a new color, size, or shape of the object was presented. Zebrafish showed discrimination for color, shape, and color+shape combined, but not size. These results imply that zebrafish seem to use some categorical system to discriminate items, and distracters affect their ability for discrimination. The type of variables available (color and shape) may favor zebrafish objects perception and facilitate discrimination processing. We suggest that this easy and simple memory test could serve as a useful screening tool for cognitive dysfunction and neurotoxicological studies.

  18. In the Field Feasibility of a Simple Method to Check for Radioactivity in Commodities and in the Environment

    PubMed Central

    Alessandri, Stefano

    2017-01-01

    Introduction: Some release of radionuclides into the environment can be expected from the growing number of nuclear plants, either in or out of service. The citizen and the big organization could be both interested in simple and innovative methods for checking the radiological safety of their environment and of commodities, starting from foods. Methods: In this work three methods to detect radioactivity are briefly compared  focusing on the most recent, which converts a smartphone into a radiation counter. Results: The results of a simple sensitivity test are presented showing the measure of the activity of reference sources put at different distances from each sensor. Discussion: The three methods are discussed in terms of availability, technology, sensitivity, resolution and usefulness. The reported results can be usefully transferred into a radiological emergency scenario and they also offer some interesting implication for our current everyday life, but show that the hardware of the tested smart-phone can detect only high levels of radioactivity. However the technology could be interesting to build a working detection and measurement chain which could start from a diffused and networked first screening before the final high resolution analysis. PMID:28744409

  19. High-throughput fabrication and screening improves gold nanoparticle chemiresistor sensor performance.

    PubMed

    Hubble, Lee J; Cooper, James S; Sosa-Pintos, Andrea; Kiiveri, Harri; Chow, Edith; Webster, Melissa S; Wieczorek, Lech; Raguse, Burkhard

    2015-02-09

    Chemiresistor sensor arrays are a promising technology to replace current laboratory-based analysis instrumentation, with the advantage of facile integration into portable, low-cost devices for in-field use. To increase the performance of chemiresistor sensor arrays a high-throughput fabrication and screening methodology was developed to assess different organothiol-functionalized gold nanoparticle chemiresistors. This high-throughput fabrication and testing methodology was implemented to screen a library consisting of 132 different organothiol compounds as capping agents for functionalized gold nanoparticle chemiresistor sensors. The methodology utilized an automated liquid handling workstation for the in situ functionalization of gold nanoparticle films and subsequent automated analyte testing of sensor arrays using a flow-injection analysis system. To test the methodology we focused on the discrimination and quantitation of benzene, toluene, ethylbenzene, p-xylene, and naphthalene (BTEXN) mixtures in water at low microgram per liter concentration levels. The high-throughput methodology identified a sensor array configuration consisting of a subset of organothiol-functionalized chemiresistors which in combination with random forests analysis was able to predict individual analyte concentrations with overall root-mean-square errors ranging between 8-17 μg/L for mixtures of BTEXN in water at the 100 μg/L concentration. The ability to use a simple sensor array system to quantitate BTEXN mixtures in water at the low μg/L concentration range has direct and significant implications to future environmental monitoring and reporting strategies. In addition, these results demonstrate the advantages of high-throughput screening to improve the performance of gold nanoparticle based chemiresistors for both new and existing applications.

  20. Silver Nanoscale Hexagonal Column Chips for Detecting Cell-free DNA and Circulating Nucleosomes in Cancer Patients.

    PubMed

    Ito, Hiroaki; Hasegawa, Katsuyuki; Hasegawa, Yuuki; Nishimaki, Tadashi; Hosomichi, Kazuyoshi; Kimura, Satoshi; Ohba, Motoi; Yao, Hiroshi; Onimaru, Manabu; Inoue, Ituro; Inoue, Haruhiro

    2015-05-21

    Blood tests, which are commonly used for cancer screening, generally have low sensitivity. Here, we developed a novel rapid and simple method to generate silver nanoscale hexagonal columns (NHCs) for use in surface-enhanced Raman scattering (SERS). We reported that the intensity of SERS spectra of clinical serum samples obtained from gastrointestinal cancer patients is was significantly higher than that of SERS spectra of clinical serum samples obtained from non-cancer patients. We estimated the combined constituents on silver NHCs by using a field emission-type scanning electron microscope, Raman microscopes, and a 3D laser scanning confocal microscope. We obtained the Raman scattering spectra of samples of physically fractured cells and clinical serum. No spectra were obtained for chemically lysed cultured cells and DNA, RNA, and protein extracted from cultured cells. We believe that our method, which uses SERS with silver NHCs to detect circulating nucleosomes bound by methylated cell-free DNA, may be successfully implemented in blood tests for cancer screening.

  1. Guidelines for Selection, Screening and Qualification of Low-Voltage Commercial Multilayer Ceramic Capacitors for Space Programs

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2012-01-01

    This document has been developed in the course of NASA Electronic Parts and Packaging (NEPP) program and is not an official endorsement of the insertion of commercial capacitors in space programs or an established set of requirements for their testing. The purpose of this document is to suggest possible ways for selection, screening, and qualification of commercial capacitors for NASA projects and open discussions in the parts engineering community related to the use of COTS ceramic capacitors. This guideline is applicable to commercial surface mount chip, simple parallel plate design, multi-layer ceramic capacitors (MLCCs) rated to voltages of 100V and less. Parts with different design, e.g. low inductance ceramic capacitors (LICA), land grid array (LGA) etc., might need additional testing and tailoring of the requirements described in this document. Although the focus of this document is on commercial MLCCs, many procedures discussed below would be beneficial for military-grade capacitors

  2. Metabolic emergencies and the emergency physician.

    PubMed

    Fletcher, Janice Mary

    2016-02-01

    Fifty percent of inborn errors of metabolism are present in later childhood and adulthood, with crises commonly precipitated by minor viral illnesses or increased protein ingestion. Many physicians only consider IEM after more common conditions (such as sepsis) have been considered. In view of the large number of inborn errors, it might appear that their diagnosis requires precise knowledge of a large number of biochemical pathways and their interrelationship. As a matter of fact, an adequate diagnostic approach can be based on the proper use of only a few screening tests. A detailed history of antecedent events, together with these simple screening tests, can be diagnostic, leading to life-saving, targeted treatments for many disorders. Unrecognised, IEM can lead to significant mortality and morbidity. Advice is available 24/7 through the metabolic service based at the major paediatric hospital in each state and Starship Children's Health in New Zealand. © 2016 The Author. Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  3. Scoring systems for the Clock Drawing Test: A historical review

    PubMed Central

    Spenciere, Bárbara; Alves, Heloisa; Charchat-Fichman, Helenice

    2017-01-01

    The Clock Drawing Test (CDT) is a simple neuropsychological screening instrument that is well accepted by patients and has solid psychometric properties. Several different CDT scoring methods have been developed, but no consensus has been reached regarding which scoring method is the most accurate. This article reviews the literature on these scoring systems and the changes they have undergone over the years. Historically, different types of scoring systems emerged. Initially, the focus was on screening for dementia, and the methods were both quantitative and semi-quantitative. Later, the need for an early diagnosis called for a scoring system that can detect subtle errors, especially those related to executive function. Therefore, qualitative analyses began to be used for both differential and early diagnoses of dementia. A widely used qualitative method was proposed by Rouleau et al. (1992). Tracing the historical path of these scoring methods is important for developing additional scoring systems and furthering dementia prevention research. PMID:29213488

  4. Most Probable Fire Scenarios in Spacecraft and Extraterrestrial Habitats: Why NASA's Current Test 1 Might Not Always be Conservative

    NASA Technical Reports Server (NTRS)

    Olson, S. L.

    2004-01-01

    NASA's current method of material screening determines fire resistance under conditions representing a worst-case for normal gravity flammability - the Upward Flame Propagation Test (Test 1). Its simple pass-fail criteria eliminates materials that burn for more than 12 inches from a standardized ignition source. In addition, if a material drips burning pieces that ignite a flammable fabric below, it fails. The applicability of Test 1 to fires in microgravity and extraterrestrial environments, however, is uncertain because the relationship between this buoyancy-dominated test and actual extraterrestrial fire hazards is not understood. There is compelling evidence that the Test 1 may not be the worst case for spacecraft fires, and we don t have enough information to assess if it is adequate at Lunar or Martian gravity levels.

  5. Most Probable Fire Scenarios in Spacecraft and Extraterrestrial Habitats: Why NASA's Current Test 1 Might Not Always Be Conservative

    NASA Technical Reports Server (NTRS)

    Olson, S. L.

    2004-01-01

    NASA s current method of material screening determines fire resistance under conditions representing a worst-case for normal gravity flammability - the Upward Flame Propagation Test (Test 1[1]). Its simple pass-fail criteria eliminates materials that burn for more than 12 inches from a standardized ignition source. In addition, if a material drips burning pieces that ignite a flammable fabric below, it fails. The applicability of Test 1 to fires in microgravity and extraterrestrial environments, however, is uncertain because the relationship between this buoyancy-dominated test and actual extraterrestrial fire hazards is not understood. There is compelling evidence that the Test 1 may not be the worst case for spacecraft fires, and we don t have enough information to assess if it is adequate at Lunar or Martian gravity levels.

  6. Efficient screening for COPD using three steps: a cross-sectional study in Mexico City.

    PubMed

    Franco-Marina, Francisco; Fernandez-Plata, Rosario; Torre-Bouscoulet, Luis; García-Sancho, Cecilia; Sanchez-Gallen, Elisa; Martinez, David; Perez-Padilla, Rogelio

    2014-05-20

    Underdiagnosis of chronic obstructive pulmonary disease (COPD) in primary care can be improved by a more efficient screening strategy. To evaluate a three-step method of screening for COPD consisting of an initial short questionnaire followed by measurement of forced expiratory volume in 1s/forced expiratory volume in 6s (FEV1/FEV6) using an inexpensive pocket spirometer in those with high risk, and diagnostic quality spirometry in those with a low FEV1/FEV6. We analysed two related Mexico City cross-sectional samples. The 2003 Mexico City PLATINO survey (n=542) was used to develop a short questionnaire to determine the risk of COPD and a 2010 survey (n=737) additionally used a pocket spirometer. The discriminatory power of the two instruments was assessed with receiver operator characteristic (ROC) curves using three COPD definitions. The developed COPD scale included two variables from a simple questionnaire and, in ROC analysis, an area under the curve (AUC) between 0.64 and 0.77 was found to detect COPD. The pocket spirometer had an AUC between 0.85 and 0.88 to detect COPD. Using the COPD scale as a first screening step excluded 35-48% of the total population from further testing at the cost of not detecting 8-18% of those with COPD. Using the pocket spirometer and sending those with a FEV1/FEV6<0.80 for diagnostic quality spirometry is very efficient, and substantially improved the positive predictive value at the cost of not detecting one-third of COPD cases. A three-step screening strategy for COPD substantially reduces the need for spirometry testing when only a COPD scale is used for screening.

  7. Effectiveness of three interventions to improve participation in colorectal cancer screening.

    PubMed

    López-Torres Hidalgo, Jesús; Rabanales Sotos, Joseba; Simarro Herráez, María José; López-Torres López, Jaime; Campos Rosa, Monchi; López Verdejo, María Ángeles

    2016-06-01

    Participation in colorectal cancer (CRC) screening varies widely among different countries and different socio-demographic groups. Our objective was to assess the effectiveness of three primary-care interventions to increase CRC screening participation among persons over the age of 50 years and to identify the health and socio-demographic-related factors that determine greater participation. We conducted a randomized experimental study with only one post-test control group. A total of 1,690 subjects were randomly distributed into four groups: written briefing; telephone briefing; an invitation to attend a group meeting; and no briefing. Subjects were evaluated 2 years post-intervention, with the outcome variable being participation in CRC screening. A total of 1,129 subjects were interviewed. Within the groups, homogeneity was tested in terms of socio-demographic characteristics and health-related variables. The proportion of subjects who participated in screening was: 15.4% in the written information group (95% confidence interval [CI]: 11.2-19.7); 28.8% in the telephone information group (95% CI: 23.6-33.9); 8.1% in the face-to-face information group (95% CI: 4.5-11.7); and 5.9% in the control group (95% CI: 2.9-9.0), with this difference proving statistically significant (p < 0.001). Logistic regression showed that only interventions based on written or telephone briefing were effective. Apart from type of intervention, number of reported health problems and place of residence remained in the regression model. Both written and telephone information can serve to improve participation in CRC screening. This preventive activity could be optimized by means of simple interventions coming within the scope of primary health-care professionals.

  8. Development of a screening tool to predict malnutrition among children under two years old in Zambia

    PubMed Central

    Hasegawa, Junko; Ito, Yoichi M; Yamauchi, Taro

    2017-01-01

    ABSTRACT Background: Maternal and child undernutrition is an important issue, particularly in low- and middle-income countries. Children at high risk of malnutrition should be prioritized to receive necessary interventions to minimize such risk. Several risk factors have been proposed; however, until now, there has been no appropriate evaluation method to identify these children. In sub-Saharan Africa, children commonly receive regular check-ups from community health workers. A simple and easy nutrition assessment method is therefore needed for use by semi-professional health workers. Objectives: The aim of this study was to develop and test a practical screening tool for community use in predicting growth stunting in children under two years in rural Zambia. Methods: Field research was conducted from July to August 2014 in Southern Province, Zambia. Two hundred and sixty-four mother-child pairs participated in the study. Anthropometric measurements were performed on all children and mothers, and all mothers were interviewed. Risk factors for the screening test were estimated by using least absolute shrinkage and selection operator analysis. After re-evaluating all participants using the new screening tool, a receiver operating characteristic curve was drawn to set the cut-off value. Sensitivity and specificity were also calculated. Results: The screening tool included age, weight-for-age Z-score status, birth weight, feeding status, history of sibling death, multiple birth, and maternal education level. The total score ranged from 0 to 22, and the cut-off value was eight. Sensitivity and specificity were 0.963 and 0.697 respectively. Conclusions: A screening tool was developed to predict children at high risk of malnutrition living in Zambia. Further longitudinal studies are needed to confirm the test’s validity in detecting future stunting and to investigate the effectiveness of malnutrition treatment. PMID:28730929

  9. Evaluation of recently validated non-invasive formula using basic lung functions as new screening tool for pulmonary hypertension in idiopathic pulmonary fibrosis patients

    PubMed Central

    Ghanem, Maha K.; Makhlouf, Hoda A.; Agmy, Gamal R.; Imam, Hisham M. K.; Fouad, Doaa A.

    2009-01-01

    BACKGROUND: A prediction formula for mean pulmonary artery pressure (MPAP) using standard lung function measurement has been recently validated to screen for pulmonary hypertension (PH) in idiopathic pulmonary fibrosis (IPF) patients. OBJECTIVE: To test the usefulness of this formula as a new non invasive screening tool for PH in IPF patients. Also, to study its correlation with patients' clinical data, pulmonary function tests, arterial blood gases (ABGs) and other commonly used screening methods for PH including electrocardiogram (ECG), chest X ray (CXR), trans-thoracic echocardiography (TTE) and computerized tomography pulmonary angiography (CTPA). MATERIALS AND METHODS: Cross-sectional study of 37 IPF patients from tertiary hospital. The accuracy of MPAP estimation was assessed by examining the correlation between the predicted MPAP using the formula and PH diagnosed by other screening tools and patients' clinical signs of PH. RESULTS: There was no statistically significant difference in the prediction of PH using cut off point of 21 or 25 mm Hg (P = 0.24). The formula-predicted MPAP greater than 25 mm Hg strongly correlated in the expected direction with O2 saturation (r = −0.95, P < 0.000), partial arterial O2 tension (r = −0.71, P < 0.000), right ventricular systolic pressure measured by TTE (r = 0.6, P < 0.000) and hilar width on CXR (r = 0.31, P = 0.03). Chest symptoms, ECG and CTPA signs of PH poorly correlated with the same formula (P > 0.05). CONCLUSIONS: The prediction formula for MPAP using standard lung function measurements is a simple non invasive tool that can be used as TTE to screen for PH in IPF patients and select those who need right heart catheterization. PMID:19881164

  10. Detection of Large Pathogenic Expansions in FRDA1, SCA10, and SCA12 Genes Using a Simple Fluorescent Repeat-Primed PCR Assay

    PubMed Central

    Cagnoli, Claudia; Michielotto, Chiara; Matsuura, Tohru; Ashizawa, Tetsuo; Margolis, Russell L.; Holmes, Susan E.; Gellera, Cinzia; Migone, Nicola; Brusco, Alfredo

    2004-01-01

    At least 18 human genetic diseases are caused by expansion of short tandem repeats. Here we describe a successful application of a fluorescent PCR method for the detection of expanded repeats in FRDA1, SCA10, and SCA12 genes. Although this test cannot give a precise estimate of the size of the expansion, it is robust, reliable, and inexpensive, and can be used to screen large series of patients. It proved useful for confirming the presence of large expansions in the Friedreich ataxia gene following an ambiguous result of long-range PCR, as well as rapid pre-screening for large repeat expansions associated with Friedreich ataxia and SCA10 and the shorter repeat expansions associated with SCA12. PMID:15096564

  11. Nutrition screening tools: an analysis of the evidence.

    PubMed

    Skipper, Annalynn; Ferguson, Maree; Thompson, Kyle; Castellanos, Victoria H; Porcari, Judy

    2012-05-01

    In response to questions about tools for nutrition screening, an evidence analysis project was developed to identify the most valid and reliable nutrition screening tools for use in acute care and hospital-based ambulatory care settings. An oversight group defined nutrition screening and literature search criteria. A trained analyst conducted structured searches of the literature for studies of nutrition screening tools according to predetermined criteria. Eleven nutrition screening tools designed to detect undernutrition in patients in acute care and hospital-based ambulatory care were identified. Trained analysts evaluated articles for quality using criteria specified by the American Dietetic Association's Evidence Analysis Library. Members of the oversight group assigned quality grades to the tools based on the quality of the supporting evidence, including reliability and validity data. One tool, the NRS-2002, received a grade I, and 4 tools-the Simple Two-Part Tool, the Mini-Nutritional Assessment-Short Form (MNA-SF), the Malnutrition Screening Tool (MST), and Malnutrition Universal Screening Tool (MUST)-received a grade II. The MST was the only tool shown to be both valid and reliable for identifying undernutrition in the settings studied. Thus, validated nutrition screening tools that are simple and easy to use are available for application in acute care and hospital-based ambulatory care settings.

  12. PTSD-8: A Short PTSD Inventory

    PubMed Central

    Hansen, Maj; Andersen, Tonny Elmose; Armour, Cherie; Elklit, Ask; Palic, Sabina; Mackrill, Thomas

    2010-01-01

    Traumatic events pose great challenges on mental health services in scarcity of specialist trauma clinicians and services. Simple short screening instruments for detecting adverse psychological responses are needed. Several brief screening instruments have been developed. However, some are limited, especially in relation to reflecting the posttraumatic stress disorder (PTSD) diagnosis. Recently, several studies have challenged pre-existing ideas about PTSD’s latent structure. Factor analytic research currently supports two four factor models. One particular model contains a dysphoria factor which has been associated with depression and anxiety. The symptoms in this factor have been hailed as less specific to PTSD. The scope of this article is therefore to present a short screening instrument, based on this research; Posttraumatic Stress Disorder (PTSD) – 8 items. The PTSD-8 is shown to have good psychometric properties in three independent samples of whiplash patients (n=1710), rape victims (n=305), and disaster victims (n=516). Good test-rest reliability is also shown in a pilot study of young adults from families with alcohol problems (n=56). PMID:21253461

  13. PTSD-8: A Short PTSD Inventory.

    PubMed

    Hansen, Maj; Andersen, Tonny Elmose; Armour, Cherie; Elklit, Ask; Palic, Sabina; Mackrill, Thomas

    2010-09-28

    Traumatic events pose great challenges on mental health services in scarcity of specialist trauma clinicians and services. Simple short screening instruments for detecting adverse psychological responses are needed. Several brief screening instruments have been developed. However, some are limited, especially in relation to reflecting the posttraumatic stress disorder (PTSD) diagnosis. Recently, several studies have challenged pre-existing ideas about PTSD's latent structure. Factor analytic research currently supports two four factor models. One particular model contains a dysphoria factor which has been associated with depression and anxiety. The symptoms in this factor have been hailed as less specific to PTSD. The scope of this article is therefore to present a short screening instrument, based on this research; Posttraumatic Stress Disorder (PTSD) - 8 items. The PTSD-8 is shown to have good psychometric properties in three independent samples of whiplash patients (n=1710), rape victims (n=305), and disaster victims (n=516). Good test-rest reliability is also shown in a pilot study of young adults from families with alcohol problems (n=56).

  14. Screening and syndromic approaches to identify gonorrhea and chlamydial infection among women.

    PubMed

    Sloan, N L; Winikoff, B; Haberland, N; Coggins, C; Elias, C

    2000-03-01

    The standard diagnostic tools to identify sexually transmitted infections are often expensive and have laboratory and infrastructure requirements that make them unavailable to family planning and primary health-care clinics in developing countries. Therefore, inexpensive, accessible tools that rely on symptoms, signs, and/or risk factors have been developed to identify and treat reproductive tract infections without the need for laboratory diagnostics. Studies were reviewed that used standard diagnostic tests to identify gonorrhea and cervical chlamydial infection among women and that provided adequate information about the usefulness of the tools for screening. Aggregation of the studies' results suggest that risk factors, algorithms, and risk scoring for syndromic management are poor indicators of gonorrhea and chlamydial infection in samples of both low and high prevalence and, consequently, are not effective mechanisms with which to identify or manage these conditions. The development and evaluation of other approaches to identify gonorrhea and chlamydial infections, including inexpensive and simple laboratory screening tools, periodic universal treatment, and other alternatives must be given priority.

  15. Screening actuator locations for static shape control

    NASA Technical Reports Server (NTRS)

    Haftka, Raphael T.

    1990-01-01

    Correction of shape distortion due to zero-mean normally distributed errors in structural sizes which are random variables is examined. A bound on the maximum improvement in the expected value of the root-mean-square shape error is obtained. The shape correction associated with the optimal actuators is also characterized. An actuator effectiveness index is developed and shown to be helpful in screening actuator locations in the structure. The results are specialized to a simple form for truss structures composed of nominally identical members. The bound and effectiveness index are tested on a 55-m radiometer antenna truss structure. It is found that previously obtained results for optimum actuators had a performance close to the bound obtained here. Furthermore, the actuators associated with the optimum design are shown to have high effectiveness indices. Since only a small fraction of truss elements tend to have high effectiveness indices, the proposed screening procedure can greatly reduce the number of truss members that need to be considered as actuator sites.

  16. A review of current sleep screening applications for smartphones.

    PubMed

    Behar, Joachim; Roebuck, Aoife; Domingos, João S; Gederi, Elnaz; Clifford, Gari D

    2013-07-01

    Sleep disorders are a common problem and contribute to a wide range of healthcare issues. The societal and financial costs of sleep disorders are enormous. Sleep-related disorders are often diagnosed with an overnight sleep test called a polysomnogram, or sleep study involving the measurement of brain activity through the electroencephalogram. Other parameters monitored include oxygen saturation, respiratory effort, cardiac activity (through the electrocardiogram), as well as video recording, sound and movement activity. Monitoring can be costly and removes the patients from their normal sleeping environment, preventing repeated unbiased studies. The recent increase in adoption of smartphones, with high quality on-board sensors has led to the proliferation of many sleep screening applications running on the phone. However, with the exception of simple questionnaires, no existing sleep-related application available for smartphones is based on scientific evidence. This paper reviews the existing smartphone applications landscape used in the field of sleep disorders and proposes possible advances to improve screening approaches.

  17. Early Recovery of Aphasia through Thrombolysis: The Significance of Spontaneous Speech.

    PubMed

    Furlanis, Giovanni; Ridolfi, Mariana; Polverino, Paola; Menichelli, Alina; Caruso, Paola; Naccarato, Marcello; Sartori, Arianna; Torelli, Lucio; Pesavento, Valentina; Manganotti, Paolo

    2018-07-01

    Aphasia is one of the most devastating stroke-related consequences for social interaction and daily activities. Aphasia recovery in acute stroke depends on the degree of reperfusion after thrombolysis or thrombectomy. As aphasia assessment tests are often time-consuming for patients with acute stroke, physicians have been developing rapid and simple tests. The aim of our study is to evaluate the improvement of language functions in the earliest stage in patients treated with thrombolysis and in nontreated patients using our rapid screening test. Our study is a single-center prospective observational study conducted at the Stroke Unit of the University Medical Hospital of Trieste (January-December 2016). Patients treated with thrombolysis and nontreated patients underwent 3 aphasia assessments through our rapid screening test (at baseline, 24 hours, and 72 hours). The screening test assesses spontaneous speech, oral comprehension of words, reading aloud and comprehension of written words, oral comprehension of sentences, naming, repetition of words and a sentence, and writing words. The study included 40 patients: 18 patients treated with thrombolysis and 22 nontreated patients. Both groups improved over time. Among all language parameters, spontaneous speech was statistically significant between 24 and 72 hours (P value = .012), and between baseline and 72 hours (P value = .017). Our study demonstrates that patients treated with thrombolysis experience greater improvement in language than the nontreated patients. The difference between the 2 groups is increasingly evident over time. Moreover, spontaneous speech is the parameter marked by the greatest improvement. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Simple, rapid, and cost-effective modified Carba NP test for carbapenemase detection among Gram-negative bacteria

    PubMed Central

    Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha

    2017-01-01

    PURPOSE: Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. MATERIALS AND METHODS: The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. RESULTS: A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. CONCLUSION: The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings. PMID:28966495

  19. Simple, rapid, and cost-effective modified Carba NP test for carbapenemase detection among Gram-negative bacteria.

    PubMed

    Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha

    2017-01-01

    Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings.

  20. A simple semi-rapid HIV-1&2 confirmatory immunoassay using magnetic particles.

    PubMed

    Sommerfelt, Maja A; Ohlsson, Irene; Flolid, Irene; Thorstensson, Rigmor; Sørensen, Birger

    2004-02-01

    The Bionor HIV-1&2 Confirmatory Test is a semi-rapid simple immunoassay based on magnetic particles for the confirmation of serological status to human immunodeficiency virus (HIV). The specificity and sensitivity of this assay was evaluated by comparison with the Diagnostic Biotechnology HIV-1 Western blot (WB) 2.2 and the HIV-2/SBL-6669 WB. Bionor's confirmatory test demonstrated 98% specificity when testing sero-negative blood donors and false positive sera in screening tests compared to 81.5 and 71.6%, respectively, using the HIV-1 WB. The sensitivity of this assay for HIV-1 antibody positive sera was 97.9% compared to the WB which was 99.5%. When testing confirmed HIV-2 antibody positive samples, 2/100 scored negative using this confirmatory test similar to other HIV-2 peptide-based line immunoassays available commercially, whilst 8/100 were indeterminate reacting to HIV-2 membrane antigens only. Bionor's confirmatory test detected HIV-1 seropositivity earlier than the WB in longitudinal seroconversion panels and could discriminate between HIV-1 and -2 infection. The number of indeterminate responses was generally reduced significantly using Bionor's confirmatory test compared to the HIV-1 WB. The greater specificity, speed and ease of interpretation of Bionor's confirmatory test renders it an attractive and cost effective alternative to the WB for confirming HIV serological status worldwide.

  1. Development and validation of a fast and simple multi-analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC-MS and one-point calibration.

    PubMed

    Meyer, Golo M J; Weber, Armin A; Maurer, Hans H

    2014-05-01

    Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1 h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples. Copyright © 2013 John Wiley & Sons, Ltd.

  2. AmpC β-lactamases in nosocomial isolates of Klebsiella pneumoniae from India

    PubMed Central

    Gupta, Varsha; Kumarasamy, Karthikeyan; Gulati, Neelam; Garg, Ritu; Krishnan, Padma; Chander, Jagdish

    2012-01-01

    Background & objectives: AmpC β-lactamases are clinically significant since these confer resistance to cephalosporins in the oxyimino group, 7-α methoxycephalosporins and are not affected by available β-lactamase inhibitors. In this study we looked for both extended spectrum β-lactamases (ESBL) and AmpC β-lactamases in Klebsiella pneumoniae clinical isolates. Methods: One hundred consecutive, non-duplicate clinical isolates of K. pneumoniae collected over a period of one year (June 2008 - June 2009) were included in the study. An antibiotic susceptibility method was used with 10 antibiotics for Gram-negative infections which helped in screening for ESBL and AmpC β-lactamases and also in confirmation of ESBL production. The detection of AmpC β-lactamases was done based on screening and confirmatory tests. For screening, disc diffusion zones of cefoxitin <18 mm was taken as cefoxitin resistant. All cefoxitin resistant isolates were tested further by AmpC disk test and modified three dimensional test. Multiplex-PCR was performed for screening the presence of plasmid-mediated AmpC genes. Results: Of the 100 isolates of K. pneumoniae studied, 48 were resistant to cefoxitin on screening. AmpC disk test was positive in 32 (32%) isolates. This was also confirmed with modified three dimensional test. Indentation indicating strong AmpC producer was observed in 25 isolates whereas little distortion (weak AmpC) was observed in 7 isolates. ESBL detection was confirmed by a modification of double disk synergy test in 56 isolates. Cefepime was the best cephalosporin in synergy with tazobactam for detecting ESBL production in isolates co-producing AmpC β-lactamases. The subsets of isolates phenotypically AmpC β-lactamase positive were subjected to amplification of six different families of AmpC gene using multiplex PCR. The sequence analysis revealed 12 CMY-2 and eight DHA-1 types. Interpretation & conclusions: Tazobactam was the best β-lactamase inhibitor for detecting ESBL in presence of AmpC β-lactamase as this is a very poor inducer of AmpC gene. Amongst cephalosporins, cefepime was the best cephalosporin in detecting ESBL in presence of AmpC β-lactamase as it is least hydrolyzed by AmpC enzymes. Cefepime-tazobactam combination disk test would be a simple and best method in detection of ESBLs in Enterobacteriaceae co-producing AmpC β-lactamase in the routine diagnostic microbiology laboratories. PMID:22960890

  3. Mammography screening. Benefits, harms, and informed choice.

    PubMed

    Jørgensen, Karsten Juhl

    2013-04-01

    The rationale for breast cancer screening with mammography is deceptively simple: catch it early and reduce mortality from the disease and the need for mastectomies. But breast cancer is a complex problem, and complex problems rarely have simple solutions. Breast screening brings forward the time of diagnosis only slightly compared to the lifetime of a tumour, and screen-detected tumours have a size where metastases are possible. A key question is if screening can prevent metastases, and if the screen-detected tumours are small enough to allow breast conserving surgery rather than mastectomy. A mortality reduction can never justify a medical intervention in its own right, but must be weighed against the harms. Overdiagnosis is the most important harm of breast screening, but has gained wider recognition only in recent years. Screening leads to the detection and treatment of breast cancers that would otherwise never have been detected because they grow very slowly or not at all and would not have been detected in the woman's lifetime in the absence of screening. Screening therefore turns women into cancer patients unnecessarily, with life-long physical and psychological harms. The debate about the justification of breast screening is therefore not a simple question of whether screening reduces breast cancer mortality. This dissertation quantifies the primary benefits and harms of screening mammography. Denmark has an unscreened "control group" because only two geographical regions offered screening over a long time-period, which is unique in an international context. This was used to study breast cancer mortality, overdiagnosis, and the use of mastectomies. Also, a systematic review of overdiagnosis in five other countries allowed us to show that about half of the screen-detected breast cancers are overdiagnosed. An effect on breast cancer mortality is doubtful in today's setting, and overdiagnosis causes an increase in the use of mastectomies. These findings are discussed in the context of tumour biology and stage at diagnosis. The information provided to women in invitations and on the Internet exaggerates benefits, participation is directly recommended, and the harms are downplayed or left out, despite agreement that the objective is informed choice. This raises an ethical discussion concerning autonomy versus paternalism, and the difficulty in weighing benefits against harms. Finally, financial, political, and professional conflicts of interest are discussed, as well as health economics.

  4. Shortcomings in bladder cancer etiology research and a model for its prevention.

    PubMed

    Radosavljevic, Vladan; Belojevic, Goran

    2014-01-01

    Bladder cancer (BC) is the most expensive cancer to treat. Its incidence and mortality have not decreased in the last three decades. Numerous uncertainties are still surrounding the etiology of BC. There is a need for a low-cost screening test for BC that would be applicable for early detection in asymptomatic persons, a test that would preferably be noninvasive and have satisfactory sensitivity and specificity. The first part of this paper addresses critical issues in the research into BC etiology, which we classified as entrances, toxicity and metabolism, amounts, and duration of exposure to carcinogens in the bladder. In the second part, based on the proven risk factors for BC, we present a simple scoring system as part of a new BC screening method. The heterogeneous results of studies on BC etiology are largely due to a lack of research into the compounds (and their mutual interactions) present in the urinary bladder, carcinogens absorbed through the skin and/or inhaled, and the daily dynamics of exposure to exogenous risk factors. We have calculated a score for BC screening which is an integral component of a new, four-level system of BC prevention. Interactions of carcinogens and their daily dynamics deserve more attention in further clarifying BC etiology. New attempts in BC screening should be focused on urine content analyses (carcinogens, antioxidants, vitamins, minerals) and not only on hematuria and currently used biomarkers. We propose a score for BC pre-evaluation and recruitment for screening and a new model of BC prevention.

  5. Improving Alcohol Screening for College Students: Screening for Alcohol Misuse amongst College Students with a Simple Modification to the CAGE Questionnaire

    ERIC Educational Resources Information Center

    Taylor, Purcell; El-Sabawi, Taleed; Cangin, Causenge

    2016-01-01

    Objective: To improve the CAGE (Cut down, Annoyed, Guilty, Eye opener) questionnaire's predictive accuracy in screening college students. Participants: The sample consisted of 219 midwestern university students who self-administered a confidential survey. Methods: Exploratory factor analysis, confirmatory factor analysis, receiver operating…

  6. Evaluation of a QuECHERS-like extraction approach for the determination of PBDEs in mussels by immuno-assay-based screening methods

    USDA-ARS?s Scientific Manuscript database

    A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. A simple sample preparation in conjunction with a rapid screening method possesses the desired c...

  7. A simple cell-based high throughput screening (HTS) assay for inhibitors of Salmonella enterica RNA polymerase containing the general stress response regulator RpoS (σS).

    PubMed

    Campos-Gomez, Javier; Benitez, Jorge A

    2018-07-01

    RNA polymerase containing the stress response regulator σ S subunit (RpoS) plays a key role in bacterial survival in hostile environments in nature and during infection. Here we devise and validate a simple cell-based high throughput luminescence assay for this holoenzyme suitable for screening large chemical libraries in a robotic platform. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Correlation of Michigan neuropathy screening instrument, United Kingdom screening test and electrodiagnosis for early detection of diabetic peripheral neuropathy.

    PubMed

    Fateh, Hamid R; Madani, Seyed Pezhman; Heshmat, Ramin; Larijani, Bagher

    2015-01-01

    Almost half of Diabetic Peripheral Neuropathies (DPNs) are symptom-free. Methods including questionnaires and electrodiagnosis (EDx) can be fruitful for easy reach to early diagnosis, correct treatments of diabetic neuropathy, and so decline of complications for instance diabetic foot ulcer and prevention of high costs. The goal of our study was to compare effectiveness of the Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST) and electrophysiological evaluation in confirming diabetic peripheral neuropathy. One hundred twenty five known diabetes mellitus male and female subjects older than 18 with or without symptoms of neuropathy comprised in this research. All of them were interviewed in terms of demographic data, lipid profile, HbA1C, duration of disease, and history of retinopathy, so examined by Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST), and nerve conduction studies (NCS). The collected data were analyzed by SPSS software 18. One hundred twenty five diabetic patients (70 female, 55 male) were recruited in this study with a mean age of 58.7 ± 10.2, and mean duration of diabetes was 10.17 ± 6.9 years. The mean neuropathy score of MNSI and UKST were 2.3 (1.7) and 4.16 (2.9), respectively. Each instrument detected the peripheral neuropathy in 78 (69 %) and 91 (73 %) of patients, respectively. There was a significant relationship between number of neuropathies and mean of diabetes duration and development of retinopathy in both questionnaire evaluations and NCS. By nerve conduction study, neuropathy was detected in 121 (97 %) diabetic patients were reported in order 15 (12 %) mononeuropathy (as 33 % sensory and 67 % motor neuropathy) and 106 (85 %) polyneuropathy (as 31 % motor and 69 % sensorimotor neuropathy). As regards NCS is an objective, simple, and non-invasive tool and also can determine level of damage and regeneration in peripheral nerves, this study suggests electrodiagnosis as a convenient option for screening, confirming, and follow up of diabetic peripheral neuropathy.

  9. Influence of In-Well Convection on Well Sampling

    USGS Publications Warehouse

    Vroblesky, Don A.; Casey, Clifton C.; Lowery, Mark A.

    2006-01-01

    Convective transport of dissolved oxygen (DO) from shallow to deeper parts of wells was observed as the shallow water in wells in South Carolina became cooler than the deeper water in the wells due to seasonal changes. Wells having a relatively small depth to water were more susceptible to thermally induced convection than wells where the depth to water was greater because the shallower water levels were more influenced by air temperature. The potential for convective transport of DO to maintain oxygenated conditions in a well was diminished as ground-water exchange through the well screen increased and as oxygen demand increased. Convective flow did not transport oxygen to the screened interval when the screened interval was deeper than the range of the convective cell. The convective movement of water in wells has potential implications for passive, or no-purge, and low-flow sampling approaches. Transport of DO to the screened interval can adversely affect the ability of passive samplers to produce accurate concentrations of oxygen-sensitive solutes, such as iron. Other potential consequences include mixing the screened-interval water with casing water and potentially allowing volatilization loss at the water surface. A field test of diffusion samplers in a convecting well during the winter, however, showed good agreement of chlorinated solvent concentrations with pumped samples, indicating that there was no negative impact of the convection on the utility of the samplers to collect volatile organic compound concentrations in that well. In the cases of low-flow sampling, convective circulation can cause the pumped sample to be a mixture of casing water and aquifer water. This can substantially increase the equilibration time of oxygen as an indicator parameter and can give false indications of the redox state. Data from this investigation show that simple in-well devices can effectively mitigate convective transport of oxygen. The devices can range from inflatable packers to simple baffle systems.

  10. Screening Utility of the King-Devick Test in Mild Cognitive Impairment and Alzheimer Disease Dementia.

    PubMed

    Galetta, Kristin M; Chapman, Kimberly R; Essis, Maritza D; Alosco, Michael L; Gillard, Danielle; Steinberg, Eric; Dixon, Diane; Martin, Brett; Chaisson, Christine E; Kowall, Neil W; Tripodis, Yorghos; Balcer, Laura J; Stern, Robert A

    2017-01-01

    The King-Devick (K-D) test is a 1 to 2 minute, rapid number naming test, often used to assist with detection of concussion, but also has clinical utility in other neurological conditions (eg, Parkinson disease). The K-D involves saccadic eye and other eye movements, and abnormalities thereof may be an early indicator of Alzheimer disease (AD)-associated cognitive impairment. No study has tested the utility of the K-D in AD and we sought to do so. The sample included 206 [135 controls, 39 mild cognitive impairment (MCI), and 32 AD dementia] consecutive subjects from the Boston University Alzheimer's Disease Center registry undergoing their initial annual evaluation between March 2013 and July 2015. The K-D was administered during this period. Areas under the receiver operating characteristic curves generated from logistic regression models revealed the K-D test distinguished controls from subjects with cognitive impairment (MCI and AD dementia) [area under the curve (AUC)=0.72], MCI (AUC=0.71) and AD dementia (AUC=0.74). K-D time scores between 48 and 52 seconds were associated with high sensitivity (>90.0%) and negative predictive values (>85.0%) for each diagnostic group. The K-D correlated strongly with validated attention, processing speed, and visual scanning tests. The K-D test may be a rapid and simple effective screening tool to detect cognitive impairment associated with AD.

  11. [Screening methods for mild cognitive impairment in primary care].

    PubMed

    Freire Pérez, Alberto

    2017-06-01

    Diagnosis of mild cognitive impairment (MCI) is always clinical and screening methods only indicate that the patient has a higher risk of this condition. In MCI, there is a slight decline in some cognitive abilities that does not affect activities of daily living and therefore does not produce social or occupational disability. The definitive diagnosis of MCI requires a considerable time investment that is very rarely possible to provide in primary care (PC) consultations. Hence the need for PC physicians to employ rapid and simple screening methods (brief cognitive assessment -BCA-) that allow objective identification of patients likely to have MCI in a few minutes. This article reviews the BCA tools that can truly be applied in less than 10 minutes. The phototest is a brief screening tool that is easy to use and interpret by physicians and is well accepted by patients. Consequently, it is one of the most useful tests in PC for screening of both MCI and dementia. In addition to BCA, instrumental activities of daily living scales should also be applied to differentiate MCI from dementia. Copyright © 2017 Sociedad Española de Geriatría y Gerontología. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Dynamics of subcellular compartmentalization of steroid receptors in living cells as a strategic screening method to determine the biological impact of suspected endocrine disruptors.

    PubMed

    Tyagi, Rakesh Kumar

    2003-04-01

    Although a number of screening methods being used for identifying potential endocrine disruptors have generated a wealth of information, a search for alternative combination of methods is still needed to overcome experimental artefacts. There are no generally accepted or validated screening methods for monitoring and studying impact of environmental endocrine disruptors. Also, no single assay can accurately predict all the deleterious effects of endocrine disruptors. For this reason various environmental protection agencies, mainly European and US, have urged that a battery of tests in current use need to be designed to assess their adequacy in detecting the effects of endocrine disruptors. Some details about endocrine disruptors and screening programs can be found at http://www.epa.gov/scipoly/oscpendo/whatis.htm. Several studies in recent years have used fusion proteins between steroid receptors (estrogen, androgen, progesterone, etc.) and green fluorescent protein (GFP) that can serve as an alternative potent screening method to study intracellular dynamics of receptors in living cells. An approach employing nucleocytoplasmic trafficking of steroid receptors as a parameter in response to potential xenobiotic chemicals in living cells may prove to be promising in terms of being direct, fast, reliable, simple and inexpensive. Copyright 2003 Elsevier Science Ltd.

  13. Non-Asbestos Insulation Testing Using a Plasma Torch

    NASA Technical Reports Server (NTRS)

    Morgan, R. E.; Prince, A. S.; Selvidge, S. A.; Phelps, J.; Martin, C. L.; Lawrence, T. W.

    2000-01-01

    Insulation obsolescence issues are a major concern for the Reusable Solid Rocket Motor (RSRM). As old sources of raw materials disappear, new sources must be found and qualified. No simple, inexpensive test presently exists for predicting the erosion performance of a candidate insulation in the full-scale motor, Large motor tests cost million of dollars and therefore can only be used on a few very select candidates. There is a need for a simple, low cost method of screening insulation performance that can simulate some of the different erosion environments found in the RSRM. This paper describes a series of erosion tests on two different non-asbestos insulation formulations, a KEVLAR(registered) fiber-filled and a carbon fiber-filled insulation containing Ethylene-Propylene-Diene Monomer (EPDM) rubber as the binder. The test instrument was a plasma torch device. The two main variables investigated were heat flux and alumina particle impingement concentration. Statistical analysis revealed that the two different formulations had very different responses to the main variable. The results of this work indicate that there may be fundamental differences in how these insulation formulations perform in the motor operating environment. The plasma torch appears to offer a low-cost means of obtaining a fundamental understanding of insulation response to critical factors in a series of statistically designed experiments.

  14. Simple Nutrition Screening Tool for Pediatric Inpatients.

    PubMed

    White, Melinda; Lawson, Karen; Ramsey, Rebecca; Dennis, Nicole; Hutchinson, Zoe; Soh, Xin Ying; Matsuyama, Misa; Doolan, Annabel; Todd, Alwyn; Elliott, Aoife; Bell, Kristie; Littlewood, Robyn

    2016-03-01

    Pediatric nutrition risk screening tools are not routinely implemented throughout many hospitals, despite prevalence studies demonstrating malnutrition is common in hospitalized children. Existing tools lack the simplicity of those used to assess nutrition risk in the adult population. This study reports the accuracy of a new, quick, and simple pediatric nutrition screening tool (PNST) designed to be used for pediatric inpatients. The pediatric Subjective Global Nutrition Assessment (SGNA) and anthropometric measures were used to develop and assess the validity of 4 simple nutrition screening questions comprising the PNST. Participants were pediatric inpatients in 2 tertiary pediatric hospitals and 1 regional hospital. Two affirmative answers to the PNST questions were found to maximize the specificity and sensitivity to the pediatric SGNA and body mass index (BMI) z scores for malnutrition in 295 patients. The PNST identified 37.6% of patients as being at nutrition risk, whereas the pediatric SGNA identified 34.2%. The sensitivity and specificity of the PNST compared with the pediatric SGNA were 77.8% and 82.1%, respectively. The sensitivity of the PNST at detecting patients with a BMI z score of less than -2 was 89.3%, and the specificity was 66.2%. Both the PNST and pediatric SGNA were relatively poor at detecting patients who were stunted or overweight, with the sensitivity and specificity being less than 69%. The PNST provides a sensitive, valid, and simpler alternative to existing pediatric nutrition screening tools such as Screening Tool for the Assessment of Malnutrition in Pediatrics (STAMP), Screening Tool Risk on Nutritional status and Growth (STRONGkids), and Paediatric Yorkhill Malnutrition Score (PYMS) to ensure the early detection of hospitalized children at nutrition risk. © 2014 American Society for Parenteral and Enteral Nutrition.

  15. Exhaled breath analysis for lung cancer

    PubMed Central

    Sutedja, Tom G.; Zimmerman, Paul V.

    2013-01-01

    Early diagnosis of lung cancer results in improved survival compared to diagnosis with more advanced disease. Early disease is not reliably indicated by symptoms. Because investigations such as bronchoscopy and needle biopsy have associated risks and substantial costs, they are not suitable for population screening. Hence new easily applicable tests, which can be used to screen individuals at risk, are required. Biomarker testing in exhaled breath samples is a simple, relatively inexpensive, non-invasive approach. Exhaled breath contains volatile and non-volatile organic compounds produced as end-products of metabolic processes and the composition of such compounds varies between healthy subjects and subjects with lung cancer. Many studies have analysed the patterns of these compounds in exhaled breath. In addition studies have also reported that the exhaled breath condensate (EBC) can reveal gene mutations or DNA abnormalities in patients with lung cancer. This review has summarised the scientific evidence demonstrating that lung cancer has distinct chemical profiles in exhaled breath and characteristic genetic changes in EBC. It is not yet possible to accurately identify individuals with lung cancer in at risk populations by any of these techniques. However, analysis of both volatile organic compounds in exhaled breath and of EBC have great potential to become clinically useful diagnostic and screening tools for early stage lung cancer detection. PMID:24163746

  16. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    PubMed

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  17. A superhydrophobic cone to facilitate the xenomonitoring of filarial parasites, malaria, and trypanosomes using mosquito excreta/feces.

    PubMed

    Cook, Darren A N; Pilotte, Nils; Minetti, Corrado; Williams, Steven A; Reimer, Lisa J

    2017-11-06

    Background: Molecular xenomonitoring (MX), the testing of insect vectors for the presence of human pathogens, has the potential to provide a non-invasive and cost-effective method for monitoring the prevalence of disease within a community. Current MX methods require the capture and processing of large numbers of mosquitoes, particularly in areas of low endemicity, increasing the time, cost and labour required. Screening the excreta/feces (E/F) released from mosquitoes, rather than whole carcasses, improves the throughput by removing the need to discriminate vector species since non-vectors release ingested pathogens in E/F. It also enables larger numbers of mosquitoes to be processed per pool. However, this new screening approach requires a method of efficiently collecting E/F. Methods: We developed a cone with a superhydrophobic surface to allow for the efficient collection of E/F. Using mosquitoes exposed to either Plasmodium falciparum , Brugia malayi or Trypanosoma brucei brucei, we tested the performance of the superhydrophobic cone alongside two other collection methods. Results: All collection methods enabled the detection of DNA from the three parasites. Using the superhydrophobic cone to deposit E/F into a small tube provided the highest number of positive samples (16 out of 18) and facilitated detection of parasite DNA in E/F from individual mosquitoes. Further tests showed that following a simple washing step, the cone can be reused multiple times, further improving its cost-effectiveness. Conclusions: Incorporating the superhydrophobic cone into mosquito traps or holding containers could provide a simple and efficient method for collecting E/F. Where this is not possible, swabbing the container or using the washing method facilitates the detection of the three parasites used in this study.

  18. Bayesian models based on test statistics for multiple hypothesis testing problems.

    PubMed

    Ji, Yuan; Lu, Yiling; Mills, Gordon B

    2008-04-01

    We propose a Bayesian method for the problem of multiple hypothesis testing that is routinely encountered in bioinformatics research, such as the differential gene expression analysis. Our algorithm is based on modeling the distributions of test statistics under both null and alternative hypotheses. We substantially reduce the complexity of the process of defining posterior model probabilities by modeling the test statistics directly instead of modeling the full data. Computationally, we apply a Bayesian FDR approach to control the number of rejections of null hypotheses. To check if our model assumptions for the test statistics are valid for various bioinformatics experiments, we also propose a simple graphical model-assessment tool. Using extensive simulations, we demonstrate the performance of our models and the utility of the model-assessment tool. In the end, we apply the proposed methodology to an siRNA screening and a gene expression experiment.

  19. A distribution-free multi-factorial profiler for harvesting information from high-density screenings.

    PubMed

    Besseris, George J

    2013-01-01

    Data screening is an indispensable phase in initiating the scientific discovery process. Fractional factorial designs offer quick and economical options for engineering highly-dense structured datasets. Maximum information content is harvested when a selected fractional factorial scheme is driven to saturation while data gathering is suppressed to no replication. A novel multi-factorial profiler is presented that allows screening of saturated-unreplicated designs by decomposing the examined response to its constituent contributions. Partial effects are sliced off systematically from the investigated response to form individual contrasts using simple robust measures. By isolating each time the disturbance attributed solely to a single controlling factor, the Wilcoxon-Mann-Whitney rank stochastics are employed to assign significance. We demonstrate that the proposed profiler possesses its own self-checking mechanism for detecting a potential influence due to fluctuations attributed to the remaining unexplainable error. Main benefits of the method are: 1) easy to grasp, 2) well-explained test-power properties, 3) distribution-free, 4) sparsity-free, 5) calibration-free, 6) simulation-free, 7) easy to implement, and 8) expanded usability to any type and size of multi-factorial screening designs. The method is elucidated with a benchmarked profiling effort for a water filtration process.

  20. A Distribution-Free Multi-Factorial Profiler for Harvesting Information from High-Density Screenings

    PubMed Central

    Besseris, George J.

    2013-01-01

    Data screening is an indispensable phase in initiating the scientific discovery process. Fractional factorial designs offer quick and economical options for engineering highly-dense structured datasets. Maximum information content is harvested when a selected fractional factorial scheme is driven to saturation while data gathering is suppressed to no replication. A novel multi-factorial profiler is presented that allows screening of saturated-unreplicated designs by decomposing the examined response to its constituent contributions. Partial effects are sliced off systematically from the investigated response to form individual contrasts using simple robust measures. By isolating each time the disturbance attributed solely to a single controlling factor, the Wilcoxon-Mann-Whitney rank stochastics are employed to assign significance. We demonstrate that the proposed profiler possesses its own self-checking mechanism for detecting a potential influence due to fluctuations attributed to the remaining unexplainable error. Main benefits of the method are: 1) easy to grasp, 2) well-explained test-power properties, 3) distribution-free, 4) sparsity-free, 5) calibration-free, 6) simulation-free, 7) easy to implement, and 8) expanded usability to any type and size of multi-factorial screening designs. The method is elucidated with a benchmarked profiling effort for a water filtration process. PMID:24009744

  1. Comprehensive Identification Of Specific Genes Controlling Complex Traits Through A Genome-Wide Screen for Cis-Acting Regulatory Elements - An Example Using Marek's Disease

    USDA-ARS?s Scientific Manuscript database

    The comprehensive identification of genes underlying phenotypic variation of complex traits remains a major challenge. Most genome-wide screens lack sufficient resolving power as they typically depend on linkage. An alternate method is to screen for allele-specific expression (ASE), a simple yet pow...

  2. The value of ultrasonography alone in screening surveys of cystic echinococcosis in children in Turkey.

    PubMed

    Kilimcioğlu, Ali A; Ozkol, Mine; Bayindir, Petek; Girginkardeşler, Nogay; Ostan, Ipek; Ok, Ulgen Z

    2006-12-01

    A total of 1,205 primary school children were examined for cystic echinococcosis in five villages of Manisa, Turkey, to evaluate the efficacy of diagnostic methods of this infection in community-based screening surveys. Six hundred and thirty children from three villages, examined by a portable ultrasound scanner, chest microfilm and serological methods (ELISA, indirect hemagglutination) in our previous study, were designated as Study Group 1; and 575 children, from two adjacent villages, examined by ultrasonography alone in the present study, were designated as Study Group 2. In Study Group 1, hepatic cystic echinococcosis was detected in two cases (0.3%) by ultrasonography, while 43 (8.9%) and 49 (10.1%) cases were found to be positive for cystic echinococcosis by ELISA and indirect hemagglutination, respectively. Three of 575 children (0.5%) were diagnosed with cystic echinococcosis (two hepatic and one renal involvement) by ultrasonography alone in Study Group 2; and lung lesions were later detected in both cases with liver involvement by chest radiography. Our results suggested that serological tests may be beneficial in suspected cases for confirmation and differential diagnosis, but have some drawbacks, such as discrepancy in results and high false seropositivity rates. Chest microfilm is not easy in field studies and exposure to X-ray is undesirable. As a reliable, simple, inexpensive and rapid technique, ultrasonography alone is recommended to be used in community-based screening surveys for cystic echinococcosis with confirmatory tests for suspected cases found during the screening program.

  3. Non-invasive carboxyhemoglobin monitoring: screening emergency medical services patients for carbon monoxide exposure.

    PubMed

    Nilson, Douglas; Partridge, Robert; Suner, Selim; Jay, Gregory

    2010-01-01

    Carbon monoxide (CO) toxicity is a significant health problem. The use of non-invasive pulse CO-oximetry screening in the emergency department has demonstrated that the rapid screening of numerous individuals for CO toxicity is simple and capable of identifying occult cases of CO toxicity. The objective of this study was to extend the use of this handheld device to the prehospital arena, assess carboxyhemoglobin (SpCO) levels in emergency medical services (EMS) patients, and correlate these levels with clinical and demographic data. This was a retrospective, observational, chart review of adult patients transported to hospital emergency departments by urban fire department EMS ambulances during a six-week period. Each ambulance used a non-invasive pulse CO-oximeter (Rad-57, Masimo Inc.) to record patients' COHb concentrations (SpCO) along with the standard EMS assessment data. Spearman's Rank Correlation tests and Student's t-tests were used to analyze the data and calculate relationships between SpCO and other variables (age, gender, respiratory rate, heart rate, mean arterial pressure, and oxygen saturation measured by pulse oximetry). A total of 36.4% of the patients transported during the study had SpCO documented. Of the 1,017 adults included in this group, 11 (1.1%) had an SpCO >15%. There was no correlation between SpCO and heart rate, ventilatory rate, mean arterial pressure, and oxygen saturation. Screening for CO toxicity in the EMS setting is possible, and may aid in the early detection and treatment of CO-poisoned patients.

  4. Understanding the contributions of visual stimuli to contextual fear conditioning: A proof-of-concept study using LCD screens.

    PubMed

    Murawski, Nathen J; Asok, Arun

    2017-01-10

    The precise contribution of visual information to contextual fear learning and discrimination has remained elusive. To better understand this contribution, we coupled the context pre-exposure facilitation effect (CPFE) fear conditioning paradigm with presentations of distinct visual scenes displayed on 4 LCD screens surrounding a conditioning chamber. Adult male Long-Evans rats received non-reinforced context pre-exposure on Day 1, an immediate 1.5mA foot shock on Day 2, and a non-reinforced context test on Day 3. Rats were pre-exposed to either digital Context (dCtx) A, dCtx B, a distinct Ctx C, or no context on Day 1. Digital context A and B were identical except for the visual image displayed on the LCD screens. Immediate shock and retention testing occurred in dCtx A. Rats pre-exposed dCtx A showed the CPFE with significantly higher levels of freezing compared to controls. Rats pre-exposed to Context B failed to show the CPFE, with freezing that did not highly differ from controls. These results suggest that visual information contributes to contextual fear learning and that visual components of the context can be manipulated via LCD screens. Our approach offers a simple modification to contextual fear conditioning paradigms whereby the visual features of a context can be manipulated to better understand the factors that contribute to contextual fear discrimination and generalization. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. The inclusion of N-terminal pro-brain natriuretic peptide in a sensitive screening strategy for systemic sclerosis-related pulmonary arterial hypertension: a cohort study

    PubMed Central

    2013-01-01

    Introduction Pulmonary arterial hypertension (PAH) is a major cause of mortality in systemic sclerosis (SSc). Screening guidelines for PAH recommend multiple investigations, including annual echocardiography, which together have low specificity and may not be cost-effective. We sought to evaluate the predictive accuracy of serum N-terminal pro-brain natriuretic peptide (NT-proBNP) in combination with pulmonary function tests (PFT) (‘proposed’ algorithm) in a screening algorithm for SSc-PAH. Methods We evaluated our proposed algorithm (PFT with NT-proBNP) on 49 consecutive SSc patients with suspected pulmonary hypertension undergoing right heart catherisation (RHC). The predictive accuracy of the proposed algorithm was compared with existing screening recommendations, and is presented as sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results Overall, 27 patients were found to have pulmonary hypertension (PH) at RHC, while 22 had no PH. The sensitivity, specificity, PPV and NPV of the proposed algorithm for PAH was 94.1%, 54.5%, 61.5% and 92.3%, respectively; current European Society of Cardiology (ESC)/European Respiratory Society (ERS) guidelines achieved a sensitivity, specificity, PPV and NPV of 94.1%, 31.8%, 51.6% and 87.5%, respectively. In an alternate case scenario analysis, estimating a PAH prevalence of 10%, the proposed algorithm achieved a sensitivity, specificity, PPV and NPV for PAH of 94.1%, 54.5%, 18.7% and 98.8%, respectively. Conclusions The combination of NT-proBNP with PFT is a sensitive, yet simple and non-invasive, screening strategy for SSc-PAH. Patients with a positive screening result can be referred for echocardiography, and further confirmatory testing for PAH. In this way, it may be possible to shift the burden of routine screening away from echocardiography. The findings of this study should be confirmed in larger studies. PMID:24246100

  6. 1-Adamantylamine a simple urine marker for screening for third generation adamantyl-type synthetic cannabinoids by ultra-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Ford, Loretta T; Berg, Jonathan D

    2016-11-01

    Background Synthetic cannabinoids (NOIDS) are novel psychotropic drugs (NPS) currently freely sold in the United Kingdom as 'research chemicals'. Detection of NOIDS use is not available in current routine methods. Here we describe a marker which helps determine which patients have used these substances. Methods In a test case, ultra-performance liquid chromatography mass spectrometry (UPLC-Tof) was used to screen the legal high Herbal Haze II, the contents of hand-rolled cigarettes and five patient samples for NOIDS and their metabolites. Results Analysis of legal high Herbal Haze II and cigarettes identified the third generation adamantyl-type NOIDS N-(1-adamantyl)-1-pentyl-1H-indazole-3-carboxamide (AKB-48), 5F-AKB-48 and N-adamantyl-1-fluoropentylindole-3-carboxamide (STS-135). Out of 18 potential metabolites, 1-adamantylamine (C 10 H 17 N) was detected in all five urine samples. This adamantyl-type NOID marker was incorporated into our routine LC-MS/MS urine screen. Out of 14,436 random urine samples screened over eight months, 296 (2.05%) tested positive for the adamantyl-type NOID marker. Conclusion We have discovered a urine marker for identifying patients smoking legal high products containing the third generation adamantyl-type NOIDS such as AKB-48 and its fluoropentyl analogue 5F-AKB-48, which are among the most popular NOIDS currently available in legal high products sold in UK. This marker can be incorporated into routine LC-MS/MS drug screening alongside classic drugs of abuse. Positive detection rates for this new legal high marker are greater than for established classic drugs that are routinely screened such as amphetamine. This work highlights the need for a flexible toxicology screening service capable of adapting to changes in drug use such as the growing popularity of legal highs/NPS.

  7. Noninvasive Tests Do Not Accurately Differentiate Nonalcoholic Steatohepatitis From Simple Steatosis: A Systematic Review and Meta-analysis.

    PubMed

    Verhaegh, Pauline; Bavalia, Roisin; Winkens, Bjorn; Masclee, Ad; Jonkers, Daisy; Koek, Ger

    2018-06-01

    Nonalcoholic fatty liver disease is a rapidly increasing health problem. Liver biopsy analysis is the most sensitive test to differentiate between nonalcoholic steatohepatitis (NASH) and simple steatosis (SS), but noninvasive methods are needed. We performed a systematic review and meta-analysis of noninvasive tests for differentiating NASH from SS, focusing on blood markers. We performed a systematic search of the PubMed, Medline and Embase (1990-2016) databases using defined keywords, limited to full-text papers in English and human adults, and identified 2608 articles. Two independent reviewers screened the articles and identified 122 eligible articles that used liver biopsy as reference standard. If at least 2 studies were available, pooled sensitivity (sens p ) and specificity (spec p ) values were determined using the Meta-Analysis Package for R (metafor). In the 122 studies analyzed, 219 different blood markers (107 single markers and 112 scoring systems) were identified to differentiate NASH from simple steatosis, and 22 other diagnostic tests were studied. Markers identified related to several pathophysiological mechanisms. The markers analyzed in the largest proportions of studies were alanine aminotransferase (sens p , 63.5% and spec p , 74.4%) within routine biochemical tests, adiponectin (sensp, 72.0% and spec p , 75.7%) within inflammatory markers, CK18-M30 (sens p , 68.4% and spec p , 74.2%) within markers of cell death or proliferation and homeostatic model assessment of insulin resistance (sens p , 69.0% and spec p , 72.7%) within the metabolic markers. Two scoring systems could also be pooled: the NASH test (differentiated NASH from borderline NASH plus simple steatosis with 22.9% sens p and 95.3% spec p ) and the GlycoNASH test (67.1% sens p and 63.8% spec p ). In the meta-analysis, we found no test to differentiate NASH from SS with a high level of pooled sensitivity and specificity (≥80%). However, some blood markers, when included in scoring systems in single studies, identified patients with NASH with ≥80% sensitivity and specificity. Replication studies and more standardized study designs are urgently needed. At present, no marker or scoring system can be recommended for use in clinical practice to differentiate NASH from simple steatosis. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  8. A novel assay for monoacylglycerol hydrolysis suitable for high-throughput screening.

    PubMed

    Brengdahl, Johan; Fowler, Christopher J

    2006-12-01

    A simple assay for monoacylglycerol hydrolysis suitable for high-throughput screening is described. The assay uses [(3)H]2-oleoylglycerol as substrate, with the tritium label in the glycerol part of the molecule and the use of phenyl sepharose gel to separate the hydrolyzed product ([(3)H]glycerol) from substrate. Using cytosolic fractions derived from rat cerebella as a source of hydrolytic activity, the assay gives the appropriate pH profile and sensitivity to inhibition with compounds known to inhibit hydrolysis of this substrate. The assay could also be adapted to a 96-well plate format, using C6 cells as the source of hydrolytic activity. Thus the assay is simple and appropriate for high-throughput screening of inhibitors of monoacylglycerol hydrolysis.

  9. Point-of-care screening for syphilis and HIV in the borderlands: challenges in implementation in the Brazilian Amazon.

    PubMed

    Ruffinen, Carole Zen; Sabidó, Meritxell; Díaz-Bermúdez, Ximena Pamela; Lacerda, Marcus; Mabey, David; Peeling, Rosanna W; Benzaken, Adele Schwartz

    2015-11-05

    Point-of-care (POC) screening for HIV and syphilis using rapid testing was implemented in indigenous communities in the triple-border area of the Brazilian Amazon. We describe the context of the early introduction of POC screening, explore hindering and enabling factors for POC implementation, and recommend strategies for feasible, viable, and sustainable syphilis and HIV screening interventions. This was a qualitative study based on grounded theory methodology. Data were collected using in-depth interviews, semi-structured questionnaires, and field observations and were analysed using the framework approach. Qualitative information was complemented by quantitative data for descriptive purposes. An overall high score for vulnerability to acquiring HIV and syphilis was observed among the indigenous communities. Health professionals reported satisfactory rapid testing acceptance, although concerns were raised about the pain of the fingerprick. Counselling-related challenges included ensuring the accuracy of translations, collaborating with translators and communicating positive test results. Over 3 months, 86.7% of the syphilis-positive individuals began treatment, and all of them notified their partners. Accessibility, measured as travel time via the local transportation network, was a barrier to health care access. A lack of gasoline for boats and other transportation was also a hindering factor at all levels of implementation. The recommendations address the preparation phase at the coordination level as well as at the training level. Tools such as strengths, weaknesses, opportunities, and threats (SWOT) analyses; checklists; context-adapted protocols; and fact sheets are very simple methods to facilitate implementation. The findings of this study are important because they may inform the implementation of new health technologies in low-resource national disease control programmes in remote communities.

  10. Screening for physical inactivity among adults: the value of distance walked in the six-minute walk test. A cross-sectional diagnostic study.

    PubMed

    Sperandio, Evandro Fornias; Arantes, Rodolfo Leite; da Silva, Rodrigo Pereira; Matheus, Agatha Caveda; Lauria, Vinícius Tonon; Bianchim, Mayara Silveira; Romiti, Marcello; Gagliardi, Antônio Ricardo de Toledo; Dourado, Victor Zuniga

    2016-01-01

    Accelerometry provides objective measurement of physical activity levels, but is unfeasible in clinical practice. Thus, we aimed to identify physical fitness tests capable of predicting physical inactivity among adults. Diagnostic test study developed at a university laboratory and a diagnostic clinic. 188 asymptomatic subjects underwent assessment of physical activity levels through accelerometry, ergospirometry on treadmill, body composition from bioelectrical impedance, isokinetic muscle function, postural balance on a force platform and six-minute walk test. We conducted descriptive analysis and multiple logistic regression including age, sex, oxygen uptake, body fat, center of pressure, quadriceps peak torque, distance covered in six-minute walk test and steps/day in the model, as predictors of physical inactivity. We also determined sensitivity (S), specificity (Sp) and area under the curve of the main predictors by means of receiver operating characteristic curves. The prevalence of physical inactivity was 14%. The mean number of steps/day (≤ 5357) was the best predictor of physical inactivity (S = 99%; Sp = 82%). The best physical fitness test was a distance in the six-minute walk test and ≤ 96% of predicted values (S = 70%; Sp = 80%). Body fat > 25% was also significant (S = 83%; Sp = 51%). After logistic regression, steps/day and distance in the six-minute walk test remained predictors of physical inactivity. The six-minute walk test should be included in epidemiological studies as a simple and cheap tool for screening for physical inactivity.

  11. The interdependence between screening methods and screening libraries.

    PubMed

    Shelat, Anang A; Guy, R Kiplin

    2007-06-01

    The most common methods for discovery of chemical compounds capable of manipulating biological function involves some form of screening. The success of such screens is highly dependent on the chemical materials - commonly referred to as libraries - that are assayed. Classic methods for the design of screening libraries have depended on knowledge of target structure and relevant pharmacophores for target focus, and on simple count-based measures to assess other properties. The recent proliferation of two novel screening paradigms, structure-based screening and high-content screening, prompts a profound rethink about the ideal composition of small-molecule screening libraries. We suggest that currently utilized libraries are not optimal for addressing new targets by high-throughput screening, or complex phenotypes by high-content screening.

  12. Effects of a health education and telephone counseling program on patients with a positive fecal occult blood test result for colorectal cancer screening: A randomized controlled trial.

    PubMed

    Chiu, Hui-Chuan; Hung, Hsin-Yuan; Lin, Hsiu-Chen; Chen, Shu-Ching

    2017-10-01

    Our purpose was to evaluate the effects of a health education and telephone counseling program on knowledge and attitudes about colorectal cancer and screening and the psychological impact of positive screening results. A randomized controlled trial was conducted with 2 groups using a pretest and posttest measures design. Patients with positive colorectal cancer screening results were selected and randomly assigned to an experimental (n = 51) or control (n = 51) group. Subjects in the experimental group received a health education and telephone counseling program, while the control group received routine care only. Patients were assessed pretest before intervention (first visit to the outpatient) and posttest at 4 weeks after intervention (4 weeks after first visit to the outpatient). Patients in the experimental group had a significantly better level of knowledge about colorectal cancer and the psychological impact of a positive screening result than did the control group. Analysis of covariance revealed that the health education and telephone counseling program had a significant main effect on colorectal cancer knowledge. A health education and telephone counseling program can improve knowledge about colorectal cancer and about the psychological impact in patients with positive colorectal cancer screening results. The health education and telephone counseling program is an easy, simple, and convenient method of improving knowledge, improving attitudes, and alleviating psychological distress in patients with positive colorectal cancer screening results, and this program can be expanded to other types of cancer screening. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Comparison of one-tier and two-tier newborn screening metrics for congenital adrenal hyperplasia.

    PubMed

    Sarafoglou, Kyriakie; Banks, Kathryn; Gaviglio, Amy; Hietala, Amy; McCann, Mark; Thomas, William

    2012-11-01

    Newborn screening (NBS) for the classic forms of congenital adrenal hyperplasia (CAH) is mandated in all states in the United States. Compared with other NBS disorders, the false-positive rate (FPR) of CAH screening remains high and has not been significantly improved by adjusting 17α-hydroxyprogesterone cutoff values for birth weight and/or gestational age. Minnesota was the first state to initiate, and only 1 of 4 states currently performing, second-tier steroid profiling for CAH. False-negative rates (FNRs) for CAH are not well known. This is a population-based study of all Minnesota infants (769,834) born 1999-2009, grouped by screening protocol (one-tier with repeat screen, January 1999 to May 2004; two-tier with second-tier steroid profiling, June 2004 to December 2009). FPR, FNR, and positive predictive value (PPV) were calculated per infant, rather than per sample, and compared between protocols. Overall, 15 false-negatives (4 salt-wasting, 11 simple-virilizing) and 45 true-positives were identified from 1999 to 2009. With two-tier screening, FNR was 32%, FPR increased to 0.065%, and PPV decreased to 8%, but these changes were not statistically significant. Second-tier steroid profiling obviated repeat screens of borderline results (355 per year average). In comparing the 2 screening protocols, the FPR of CAH NBS remains high, the PPV remains low, and false-negatives occur more frequently than has been reported. Physicians should be cautioned that a negative NBS does not necessarily rule out classic CAH; therefore, any patient for whom there is clinical concern for CAH should receive immediate diagnostic testing.

  14. Emotional disturbance assessed by the Self-Rating Depression Scale test is associated with mortality among Japanese Hemodialysis patients.

    PubMed

    Kazama, Sakumi; Kazama, Junichiro James; Wakasugi, Minako; Ito, Yumi; Narita, Ichiei; Tanaka, Motoko; Horiguchi, Fumi; Tanigawa, Koichi

    2018-04-17

    Emotional disturbance including depression is associated with increased mortality among dialysis patients. The Self-Rating Depression Scale (SDS) is a simple tool for assessing emotional disturbance. This study investigated the relationship between emotional conditions as assessed with the SDS test and mortality among 491 hemodialysis patients. At baseline, 183 (37.3%), 180 (36.7%), 108 (22.0%), and 20 (4.1%) were classified as normal, borderline depression, depression, and severe depression, respectively. During the two years of observation period, 57 of 491 (11.6%) died. The SDS scores in the non-survivors were significantly higher than those in the survivors (p<0.0001). Logistic analyses showed that the diagnoses made by the SDS test were associated with significantly greater risks for all-cause mortality (99%CI: 1.905-3.698 for that without adjustment, 1.999-4.382 for that with full adjustment). When the SDS score = 50 was selected as the cut off value, the test screened two-year all cause death with sensitivity = 57.9% and the specificity = 78.1%. In conclusion, hemodialysis patients had high prevalence of emotional disturbance assessed by the SDS test, and high SDS score was significantly associated with all-cause mortality. These findings underscore the importance of screening for emotional conditions using the SDS test among hemodialysis patients.

  15. The urgent need for universally applicable simple screening procedures and diagnostic criteria for gestational diabetes mellitus--lessons from projects funded by the World Diabetes Foundation.

    PubMed

    Nielsen, Karoline Kragelund; de Courten, Maximilian; Kapur, Anil

    2012-01-01

    To address the risks of adverse pregnancy outcomes and future type 2 diabetes associated with gestational diabetes mellitus (GDM), its early detection and timely treatment is essential. In the absence of an international consensus, multiple different guidelines on screening and diagnosis of GDM have existed for a long time. This may be changing with the publication of the recommendations by the International Association of Diabetes and Pregnancy Study Groups. However, none of these guidelines take into account evidence from or ground realities of resource-poor settings. This study aimed to investigate whether GDM projects supported by the World Diabetes Foundation in developing countries utilize any of the internationally recommended guidelines for screening and diagnosis of GDM, explore experiences on applicability and usefulness of the guidelines and barriers if any, in implementing the guidelines. These projects have reached out to thousands of pregnant women through capacity building and improvement of access to GDM screening and diagnosis in the developing world and therefore provide a rich field experience on the applicability of the guidelines in resource-poor settings. A mixed methods approach using questionnaires and interviews was utilised to review 11 GDM projects. Two projects were conducted by the same partner; interviews were conducted in person or via phone by the first author with nine project partners and one responded via email. The interviews were analysed using content analysis. The projects use seven different screening procedures and diagnostic criteria and many do not completely adhere to one guideline alone. Various challenges in adhering to the recommendations emerged in the interviews, including problems with screening women during the recommended time period, applicability of some of the listed risk factors used for (pre-)screening, difficulties with reaching women for testing in the fasting state, time consuming nature of the tests, intolerance to high glucose load due to nausea, need for repeat tests, issues with scarcity of test consumables and lack of equipment making some procedures impossible to follow. Though an international consensus on screening and diagnosis for GDM is welcome, it should ensure that the recommendations take into account feasibility and applicability in low resource settings to ensure wider usage. We need to move away from purely academic discussions focusing on sensitivity and specificity to also include what can actually be done at the basic care level.

  16. Simple Interval Timers for Microcomputers.

    ERIC Educational Resources Information Center

    McInerney, M.; Burgess, G.

    1985-01-01

    Discusses simple interval timers for microcomputers, including (1) the Jiffy clock; (2) CPU count timers; (3) screen count timers; (4) light pen timers; and (5) chip timers. Also examines some of the general characteristics of all types of timers. (JN)

  17. Reliable Screening of Dye Phototoxicity by Using a Caenorhabditis elegans Fast Bioassay

    PubMed Central

    Bianchi, Javier Ignacio; Stockert, Juan Carlos; Buzz, Lucila Ines; Blázquez-Castro, Alfonso; Simonetta, Sergio Hernán

    2015-01-01

    Phototoxicity consists in the capability of certain innocuous molecules to become toxic when subjected to suitable illumination. In order to discover new photoactive drugs or characterize phototoxic pollutants, it would be advantageous to use simple biological tests of phototoxicy. In this work, we present a pilot screening of 37 dyes to test for phototoxic effects in the roundworm Caenorhabditis elegans. Populations of this nematode were treated with different dyes, and subsequently exposed to 30 min of white light. Behavioral outcomes were quantified by recording the global motility using an infrared tracking device (WMicrotracker). Of the tested compounds, 17 dyes were classified as photoactive, being phloxine B, primuline, eosin Y, acridine orange and rose Bengal the most phototoxic. To assess photoactivity after uptake, compounds were retested after washing them out of the medium before light irradiation. Dye uptake into the worms was also analyzed by staining or fluorescence. All the positive drugs were incorporated by animals and produced phototoxic effects after washing. We also tested the stress response being triggered by the treatments through reporter strains. Endoplasmic reticulum stress response (hsp-4::GFP strain) was activated by 22% of phototoxic dyes, and mitochondrial stress response (hsp-6::GFP strain) was induced by 16% of phototoxic dyes. These results point to a phototoxic perturbation of the protein functionality and an oxidative stress similar to that reported in cell cultures. Our work shows for the first time the feasibility of C. elegans for running phototoxic screenings and underscores its application on photoactive drugs and environmental pollutants assessment. PMID:26039060

  18. Second-tier test for quantification of underivatized amino acids in dry blood spot for metabolic diseases in newborn screening.

    PubMed

    Wang, Chunyan; Zhu, Hongbin; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying

    2013-02-01

    The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC-MS/MS method in 17-19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC-MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.

  19. Validity of Forced Eyelid Closure Test: A Novel Clinical Screening Test for Ocular Myasthenia Gravis.

    PubMed

    Apinyawasisuk, Supanut; Zhou, Xinkai; Tian, Jack J; Garcia, Giancarlo A; Karanjia, Rustum; Sadun, Alfredo A

    2017-09-01

    Forced eyelid closure test (FECT) is a clinical screening test developed from the original Cogan lid twitch (CLT) sign to assist in the diagnosis of ocular myasthenia gravis (OMG), We evaluated the sensitivity and specificity of FECT compared with CLT and benchmarked to standard diagnostic tests. This study was a retrospective chart review of 48 patients using electronic medical records of those that presented with ptosis and/or diplopia at Doheny Eye Institute, University of California, Los Angeles between February 2015 and April 2016. Patients without FECT testing were excluded. FECT and CLT results, and final diagnosis were recorded. To perform FECT, the patient was asked to squeeze his or her eyelids shut for 5-10 seconds then open quickly and fixate in primary position. The excessive upward overshoot of eyelids movement indicated a positive FECT. The test was performed by a neuro-ophthalmologist before establishing the diagnosis. Patients who had equivocal test results and/or inconclusive final diagnosis were excluded. Of the 48 patients studied, 18 patients (37.5%) had positive FECT; 15 of whom had a final diagnosis of OMG (83.3%). Of the 30 patients with negative FECT, 1 had OMG (3.3%). Of the 48 patients, 35 patients also had a documented CLT result (72.9%). CLT was positive in 11 of these 35 patients (31.4%), and 9 of these 11 had OMG (81.8%). Of the 24 patients with negative CLT, 2 of them had OMG (8.3%). Sensitivity and specificity of FECT were 94% and 91% (joint 95% confidence region: sensitivity × specificity = [0.70, 1] × [0.75, 1]). The relative true-positive fraction (rTPF) between FECT and CLT was 1.15; the relative false-positive fraction was 1.31. FECT is a simple clinical screening test with good sensitivity and specificity for OMG.

  20. Development of allele-specific multiplex PCR to determine the length of poly-T in intron 8 of CFTR

    PubMed Central

    Prada, Anne E.

    2014-01-01

    Cystic fibrosis transmembrane conductance regulator (CFTR) gene mutation analysis has been implemented for Cystic Fibrosis (CF) carrier screening, and molecular diagnosis of CF and congenital bilateral absence of the vas deferens (CBAVD). Although poly-T allele analysis in intron 8 of CFTR is required when a patient is positive for R117H, it is not recommended for routine carrier screening. Therefore, commercial kits for CFTR mutation analysis were designed either to mask the poly-T allele results, unless a patient is R117H positive, or to have the poly-T analysis as a standalone reflex test using the same commercial platform. There are other standalone assays developed to detect poly-T alleles, such as heteroduplex analysis, High Resolution Melting (HRM) curve analysis, allele-specific PCR (AS-PCR) and Sanger sequencing. In this report, we developed a simple and easy-to-implement multiplex AS-PCR assay using unlabeled standard length primers, which can be used as a reflex or standalone test for CFTR poly-T track analysis. Out of 115 human gDNA samples tested, results from our new AS-PCR matched to the previous known poly-T results or results from Sanger sequencing. PMID:25071991

  1. Development and bench testing of a multi-spectral imaging technology built on a smartphone platform

    NASA Astrophysics Data System (ADS)

    Bolton, Frank J.; Weiser, Reuven; Kass, Alex J.; Rose, Donny; Safir, Amit; Levitz, David

    2016-03-01

    Cervical cancer screening presents a great challenge for clinicians across the developing world. In many countries, cervical cancer screening is done by visualization with the naked eye. Simple brightfield white light imaging with photo documentation has been shown to make a significant impact on cervical cancer care. Adoption of smartphone based cervical imaging devices is increasing across Africa. However, advanced imaging technologies such as multispectral imaging systems, are seldom deployed in low resource settings, where they are needed most. To address this challenge, the optical system of a smartphone-based mobile colposcopy imaging system was refined, integrating components required for low cost, portable multi-spectral imaging of the cervix. This paper describes the refinement of the mobile colposcope to enable it to acquire images of the cervix at multiple illumination wavelengths, including modeling and laboratory testing. Wavelengths were selected to enable quantifying the main absorbers in tissue (oxyand deoxy-hemoglobin, and water), as well as scattering parameters that describe the size distribution of scatterers. The necessary hardware and software modifications are reviewed. Initial testing suggests the multi-spectral mobile device holds promise for use in low-resource settings.

  2. A simple device to assess and train motor coordination.

    PubMed

    Petrofsky, J S; Petrofsky, D

    2004-01-01

    The purpose of this project was to develop a computer program which can be used on a laptop or other IBM-based computer to assess and train motor coordination in children with closed head trauma or cerebral palsy. Muscle coordination was assessed by the child's ability to track a series of lines of increasing complexity. A stylus was used by the child to trace lines on a computer screen. Two different line tests were used. In the first, lines of various complexities were drawn on the screen at various angles. The child was asked to trace the line and the accuracy with which the line was traced was determined, providing a score. In a second test, a line was drawn on the screen and the child was asked to trace the line as it was drawn. The error in tracking the line and the time to track the line both were used to evaluate and score the child's performance. Finally, a 'Winnie the Pooh' character was flashed on the screen with distracters such as trees and other animals, and the child was asked to touch the Pooh. By increasing the speed of movement and decreasing the duration that the characters appeared on the screen, the child could be challenged. Successful touching of a character resulted in a positive score. Six children with cerebral palsy were compared to five children who did not have cerebral palsy, to evaluate the device. While both groups of children showed an increase in motor skills using the program, the increase seen in the children with cerebral palsy was 5-fold greater than that of the control group. While only a few children were tested with the device, the device seems to prove quite useful for physical and occupational therapy for working on motor skills in children. More investigation is warranted.

  3. Validation of a short cognitive tool for the screening of dementia in elderly people with low educational level.

    PubMed

    De Yébenes, María Jesús García; Otero, Angel; Zunzunegui, María Victoria; Rodríguez-Laso, Angel; Sánchez-Sánchez, Fernando; Del Ser, Teodoro

    2003-10-01

    To validate the 'Prueba Cognitiva de Leganés' (PCL) as a screening tool for cognitive impairment in elderly people with little formal education. The PCL is a simple cognitive test with 32 items that includes two scores of orientation and memory and a global score of 0-32 points. It was applied to a population sample of 527 elderly people over 70 with low educational level, who were independently diagnosed by consensus between two neurologists as having normal cognitive function, age associated cognitive decline (AACD, IPA-OMS criteria) or dementia (DSM-IV criteria). Individuals with severe visual or hearing defects and those who rejected the exam were excluded from the study. The PCL was validated in a sample of 375 individuals: 300 normal, 42 with AACD and 33 with dementia. The sensitivity, specificity, accuracy and likelihood ratios, as well as the ROC curves for dementia and for AACD-dementia, were calculated. The confounding effect of sociodemographic variables was assessed by logistic regression analysis and convergent validity by partial correlations of the PCL with other cognitive tests. Inter-rater reliability was evaluated with the intraclass correlation coefficient. The PCL identified dementia (cut-off < or =22) and AACD-dementia (cut-off < or =26), with the following diagnostic parameters, respectively: sensitivity 93.9%-80%, specificity 94.7%-84.3%, positive likelihood ratio 17.8-5.1, negative likelihood ratio 0.06-0.24, and accuracy 94.6%-83.4%. The areas under the ROC curve were 0.985 (95% Confidence Intervals (CI) 0.967-0.995) and 0.904 (95% CI: 0.870-0.932) respectively. The intraclass correlation coefficient was 0.79 (0.74-0.83). The PCL is a simple instrument, which is both valid and reliable, for the screening of dementia in population samples of individuals with low educational level. This instrument could be useful in primary health care. Copyright 2003 John Wiley & Sons, Ltd.

  4. The investigation and differential diagnosis of Asperger syndrome in adults.

    PubMed

    Lehnhardt, Fritz-Georg; Gawronski, Astrid; Pfeiffer, Kathleen; Kockler, Hanna; Schilbach, Leonhard; Vogeley, Kai

    2013-11-08

    As a result of the increased public interest in autism spectrum disorders (ASD), certain core manifestations of ASD--impaired social interaction and communication, bizarre interests--are now commonly recognized as being typical of autism, not only in children, but in adults as well. More often than before, general practitioners, neurologists, and psychiatrists find themselves being asked whether a patient is suffering from previously unrecognized Asperger syndrome (AS). The prevalence of ASD is estimated at 1%, and the ratio of diagnosed to undiagnosed cases at about 3:2. Little is known about the diagnostic evaluation of AS in adulthood. We selectively searched the Medline database for pertinent literature, paying special attention to diagnostic manuals and to the guideline of the United Kingdom's National Institute for Health and Care Excellence (NICE). Centrally important aspects of the diagnosis of AS include an assessment of the patient's ability to assume the emotional perspectives of others, non-verbal modes of expression, repetitive behavior patterns, and childhood social behavioral history. The autism quotient (AQ) is now established as a simple but nonspecific screening test. Up to 70% of all affected adults have comorbid disturbances, most often depression and anxiety disorders. The differential diagnosis includes personality disorders, anxiety disorders, obsessive-compulsive disorder, and attention deficit-hyperactivity disorder. The diagnostic assessment should proceed in stepwise fashion, starting from simple screening in primary care and then moving on to evaluation of the suspected diagnosis by a mental health care specialist, followed by extensive further investigation in an outpatient clinic specifically devoted to patients with autism spectrum disorders. The diagnostic assessment of autism in adults requires knowledge of the core and accompanying manifestations of autism and of their differential diagnoses. More research is needed for the development of further screening tests and the precise determination of diagnosis rates, differential diagnoses, nd comorbidities.

  5. Performance of three rapid screening methods in the detection of Schistosoma haematobium infection in school-age children in Southeastern Nigeria

    PubMed Central

    Okeke, Ogochukwu Caroline; Ubachukwu, Patience Obiageli

    2014-01-01

    Background A cross-sectional study of primary school children was conducted to evaluate and compare the performance of some rapid screening methods in the detection of Schistosoma haematobium infection in Nigeria Cement Factory (NigerCem) and Nike Lake areas of Southeastern Nigeria. Methods Urine samples of school children were examined for macro-haematuria and tested for micro-haematuria and proteinuria using reagent strips followed by egg microscopy. Self-reported haematuria was assessed using simple questionnaire. The performances of these rapid diagnoses singly and in combination were calculated using egg microscopy as gold standard. Results The prevalence of the infection was 26.6% in NigerCem and 5.1% in Nike Lake area, classifying these areas as moderate- and low-prevalence areas (MPA and LPA); while in the subsample used for self-reported haematuria, the prevalence was 27.2 and 4.2% in MPA and LPA, respectively. The positive predictive value (PPV) of micro-haematuria was comparable in MPA (55.26%) and LPA (57.89%). Overall PPV of macro-haematuria was 87.50% in MPA and 66.70% in LPA while in the detection of heavy infection; PPV was higher in LPA (75%) than in MPA (66.67%). In LPA and MPA, combination of micro-haematuria and proteinuria, and concomitant presence of macro-haematuria, micro-haematuria, and proteinuria had PPV of 83.33 and 63.16%, and 100 versus 66.67%, respectively. Generally, the rapid screening tests had lower negative predictive values (NPVs) in MPA than in LPA. The use of simple questionnaire increased the PPV of heavy infection in MPA (77.78%). This was further increased to 80% when self-reported haematuria was combined with micro-haematuria. Conclusion The result suggests that in MPA with chronic infections, combination of self-reported haematuria and micro-haematuria may reduce the chance of missing those who should be treated. PMID:24593687

  6. Performance of three rapid screening methods in the detection of Schistosoma haematobium infection in school-age children in Southeastern Nigeria.

    PubMed

    Okeke, Ogochukwu Caroline; Ubachukwu, Patience Obiageli

    2014-03-01

    A cross-sectional study of primary school children was conducted to evaluate and compare the performance of some rapid screening methods in the detection of Schistosoma haematobium infection in Nigeria Cement Factory (NigerCem) and Nike Lake areas of Southeastern Nigeria. Urine samples of school children were examined for macro-haematuria and tested for micro-haematuria and proteinuria using reagent strips followed by egg microscopy. Self-reported haematuria was assessed using simple questionnaire. The performances of these rapid diagnoses singly and in combination were calculated using egg microscopy as gold standard. The prevalence of the infection was 26·6% in NigerCem and 5·1% in Nike Lake area, classifying these areas as moderate- and low-prevalence areas (MPA and LPA); while in the subsample used for self-reported haematuria, the prevalence was 27·2 and 4·2% in MPA and LPA, respectively. The positive predictive value (PPV) of micro-haematuria was comparable in MPA (55·26%) and LPA (57·89%). Overall PPV of macro-haematuria was 87·50% in MPA and 66·70% in LPA while in the detection of heavy infection; PPV was higher in LPA (75%) than in MPA (66·67%). In LPA and MPA, combination of micro-haematuria and proteinuria, and concomitant presence of macro-haematuria, micro-haematuria, and proteinuria had PPV of 83·33 and 63·16%, and 100 versus 66·67%, respectively. Generally, the rapid screening tests had lower negative predictive values (NPVs) in MPA than in LPA. The use of simple questionnaire increased the PPV of heavy infection in MPA (77·78%). This was further increased to 80% when self-reported haematuria was combined with micro-haematuria. The result suggests that in MPA with chronic infections, combination of self-reported haematuria and micro-haematuria may reduce the chance of missing those who should be treated.

  7. Overnight dexamethasone suppression test: a reliable screen for Cushing's syndrome in the obese.

    PubMed

    Ness-Abramof, Rosane; Nabriski, Dan; Apovian, Caroline M; Niven, Mark; Weiss, Eliahu; Shapiro, Menachem S; Shenkman, Louis

    2002-12-01

    Reevaluation of the validity of the 1-mg overnight dexamethasone suppression test (ODST) as a screening test for Cushing's syndrome in obese patients. Eighty-six obese patients (body mass index, 30 to 53 kg/m(2)) that were referred to a general endocrine outpatient clinic for evaluation of simple obesity, diabetes mellitus, hypertension, polycystic ovary disease, or pituitary tumor. One milligram dexamethasone was administered orally at 11:00 PM, and serum cortisol levels were measured the following morning between 8:00 AM and 9:00 AM. Suppression of serum cortisol to <80 nM (3 micro g/dL) was chosen as the cut-off point for normal suppression. Patients with serum cortisol levels > or =80 nM were evaluated for Cushing's syndrome. Suppression of morning cortisol levels to <80 nM occurred in 79 of the 86 obese patients. Seven patients had serum cortisol levels higher than 80 nM; five were eventually diagnosed with Cushing's syndrome and two were considered false positive results in view of normal 24-hour free urinary cortisol and normal suppression on a low dose dexamethasone suppression test (0.5 mg of dexamethasone every 6 hours for 2 days). We found a false positive rate of 2.3% for the ODST using a cut-off serum cortisol of 80 nM. The ODST is a valid screening test for Cushing's syndrome in the obese population. The false positive rate was 2.3%, even when using a strict cut-off serum cortisol of 80 nM. Abnormal cortisol suppression in obese patients should be investigated and not be considered false positive results.

  8. A novel accelerated oxidative stability screening method for pharmaceutical solids.

    PubMed

    Zhu, Donghua Alan; Zhang, Geoff G Z; George, Karen L S T; Zhou, Deliang

    2011-08-01

    Despite the fact that oxidation is the second most frequent degradation pathway for pharmaceuticals, means of evaluating the oxidative stability of pharmaceutical solids, especially effective stress testing, are still lacking. This paper describes a novel experimental method for peroxide-mediated oxidative stress testing on pharmaceutical solids. The method utilizes urea-hydrogen peroxide, a molecular complex that undergoes solid-state decomposition and releases hydrogen peroxide vapor at elevated temperatures (e.g., 30°C), as a source of peroxide. The experimental setting for this method is simple, convenient, and can be operated routinely in most laboratories. The fundamental parameter of the system, that is, hydrogen peroxide vapor pressure, was determined using a modified spectrophotometric method. The feasibility and utility of the proposed method in solid form selection have been demonstrated using various solid forms of ephedrine. No degradation was detected for ephedrine hydrochloride after exposure to the hydrogen peroxide vapor for 2 weeks, whereas both anhydrate and hemihydrate free base forms degraded rapidly under the test conditions. In addition, both the anhydrate and the hemihydrate free base degraded faster when exposed to hydrogen peroxide vapor at 30°C under dry condition than at 30°C/75% relative humidity (RH). A new degradation product was also observed under the drier condition. The proposed method provides more relevant screening conditions for solid dosage forms, and is useful in selecting optimal solid form(s), determining potential degradation products, and formulation screening during development. Copyright © 2011 Wiley-Liss, Inc.

  9. Using Biowin, Bayes, and batteries to predict ready biodegradability.

    PubMed

    Boethling, Robert S; Lynch, David G; Jaworska, Joanna S; Tunkel, Jay L; Thom, Gary C; Webb, Simon

    2004-04-01

    Whether or not a given chemical substance is readily biodegradable is an important piece of information in risk screening for both new and existing chemicals. Despite the relatively low cost of Organization for Economic Cooperation and Development tests, data are often unavailable and biodegradability must be estimated. In this paper, we focus on the predictive value of selected Biowin models and model batteries using Bayesian analysis. Posterior probabilities, calculated based on performance with the model training sets using Bayes' theorem, were closely matched by actual performance with an expanded set of 374 premanufacture notice (PMN) substances. Further analysis suggested that a simple battery consisting of Biowin3 (survey ultimate biodegradation model) and Biowin5 (Ministry of International Trade and Industry [MITI] linear model) would have enhanced predictive power in comparison to individual models. Application of the battery to PMN substances showed that performance matched expectation. This approach significantly reduced both false positives for ready biodegradability and the overall misclassification rate. Similar results were obtained for a set of 63 pharmaceuticals using a battery consisting of Biowin3 and Biowin6 (MITI nonlinear model). Biodegradation data for PMNs tested in multiple ready tests or both inherent and ready biodegradation tests yielded additional insights that may be useful in risk screening.

  10. Accurate, high-throughput typing of copy number variation using paralogue ratios from dispersed repeats

    PubMed Central

    Armour, John A. L.; Palla, Raquel; Zeeuwen, Patrick L. J. M.; den Heijer, Martin; Schalkwijk, Joost; Hollox, Edward J.

    2007-01-01

    Recent work has demonstrated an unexpected prevalence of copy number variation in the human genome, and has highlighted the part this variation may play in predisposition to common phenotypes. Some important genes vary in number over a high range (e.g. DEFB4, which commonly varies between two and seven copies), and have posed formidable technical challenges for accurate copy number typing, so that there are no simple, cheap, high-throughput approaches suitable for large-scale screening. We have developed a simple comparative PCR method based on dispersed repeat sequences, using a single pair of precisely designed primers to amplify products simultaneously from both test and reference loci, which are subsequently distinguished and quantified via internal sequence differences. We have validated the method for the measurement of copy number at DEFB4 by comparison of results from >800 DNA samples with copy number measurements by MAPH/REDVR, MLPA and array-CGH. The new Paralogue Ratio Test (PRT) method can require as little as 10 ng genomic DNA, appears to be comparable in accuracy to the other methods, and for the first time provides a rapid, simple and inexpensive method for copy number analysis, suitable for application to typing thousands of samples in large case-control association studies. PMID:17175532

  11. Simple modification of basic dyes with bulky &symmetric WCAs for improving their solubilities in organic solvents without color change.

    PubMed

    Kim, Jeong Yun; Hwang, Tae Gyu; Woo, Sung Wun; Lee, Jae Moon; Namgoong, Jin Woong; Yuk, Sim Bum; Chung, Sei-Won; Kim, Jae Pil

    2017-04-06

    A simple and easy solubility enhancement of basic dyes was performed with bulky and symmetric weakly coordinating anions (WCAs). The WCAs decreased the ionic character of the dyes by broadening the partial charge distribution and causing a screening effect on the ionic bonding. This new modification with WCAs has advantages in that it has no influence on the optical properties of the dyes. The solubilities of unmodified and modified dyes were tested in several organic solvents. X-ray powder diffraction patterns of the dyes were measured. Color films were prepared with the dyes and their color loci were analyzed to evaluate the optical properties. By the modification with WCAs, commercial basic dyes showed sufficient solubilities for be applied to various applications while preserving their superior optical properties.

  12. A new simple screening method for the detection of paralytic shellfish poisoning toxins

    NASA Astrophysics Data System (ADS)

    Cheng, Jinping; Pi, Shuaishuai; Ye, Shufeng; Gao, Haomin; Yao, Lei; Jiang, Zhenyi; Song, Yuling; Xi, Lei

    2012-09-01

    The current testing for paralytic shellfish poisoning (PSP) in shellfish is based on the mouse bioassay (MBA). To alleviate animal welfare concerns, we evaluated the utility of using sublethal indicators of toxicity as an alternative to measuring time to death. Live mice were injected with a PSP congener and the changes in neurotransmitter levels were measured 60, 90, and 120 min after injection. Acetylcholine (ACh) was the most sensitive marker for PSP toxicity. The changes in neurotransmitter levels were most pronounced in the blood. Thus, measurement of Ach levels in the blood may serve as a sensitive predictor for PSP that would not require sacrifice of the mice. This method was relatively simple, sensitive (less than 1 μg/kg weight, equivalent to 20 ng/mL), low maintenance, and rapid (less than 60 min).

  13. Association between vascular calcification assessed by simple radiography and non-fatal cardiovascular events in hemodialysis patients.

    PubMed

    Petrauskiene, Vaida; Vaiciuniene, Ruta; Bumblyte, Inga Arune; Kuzminskis, Vytautas; Ziginskiene, Edita; Grazulis, Saulius; Jonaitiene, Egle

    2016-12-01

    Vascular calcification (VC) is one of the factors associated with cardiovascular mortality in hemodialysis (HD) patients. Recommendations concerning screening for VC differ. Possible ability to prevent and reversibility of VC are major subjects on debate whether screening for VC could improve outcomes of renal patients. The objective of the study was to evaluate the significance of simple vascular calcification score (SVCS) based on plane radiographic films and to test its association with non-fatal cardiovascular events in patients on chronic HD. A study population consisted of 95 prevalent HD patients in the HD unit of Hospital of Lithuanian University of Health sciences Kaunas Clinics. Clinical data and laboratory tests information were collected from medical records. SVCS was evaluated as it is described by Adragao et al. After measurement of VC, HD patients were observed for novel non-fatal cardiovascular events. Patients were divided into two groups: SVCS≥3 (57 patients [60%]) and <3 (38 patients [40%]). The Kaplan-Meier survival curves show a significant difference in non-fatal cardiovascular events in the group with SVCS≥3 vs. <3 group (26.3% vs. 7.8%; log rank 5,49; P=0.018). Multivariate Cox regression analysis confirmed a negative impact of VC, hyperphosphatemia, and lower ejection fraction on cardiovascular events. No statistically significant differences were observed comparing parameters of Ca-P metabolism disorders between groups with different SVCS. On separate analysis, the presence of VC in hands was also associated with higher rate of novel cardiovascular events (score 0 goup-5 events [10.6%] vs. score≥1 group-13 events [27%], log rank P=0.035). VC assessed by simple and inexpensive radiological method was an independent predictor of novel non-fatal cardiovascular events in HD patients. Copyright © 2016 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.

  14. A computer program (MACPUMP) for interactive aquifer-test analysis

    USGS Publications Warehouse

    Day-Lewis, F. D.; Person, M.A.; Konikow, Leonard F.

    1995-01-01

    This report introduces MACPUMP (Version 1.0), an aquifer-test-analysis package for use with Macintosh4 computers. The report outlines the input- data format, describes the solutions encoded in the program, explains the menu-items, and offers a tutorial illustrating the use of the program. The package reads list-directed aquifer-test data from a file, plots the data to the screen, generates and plots type curves for several different test conditions, and allows mouse-controlled curve matching. MACPUMP features pull-down menus, a simple text viewer for displaying data-files, and optional on-line help windows. This version includes the analytical solutions for nonleaky and leaky confined aquifers, using both type curves and straight-line methods, and for the analysis of single-well slug tests using type curves. An executable version of the code and sample input data sets are included on an accompanying floppy disk.

  15. Clinical evaluation of high-risk HPV detection on self-samples using the indicating FTA-elute solid-carrier cartridge.

    PubMed

    Geraets, D T; van Baars, R; Alonso, I; Ordi, J; Torné, A; Melchers, W J G; Meijer, C J L M; Quint, W G V

    2013-06-01

    High-risk human papillomavirus (hrHPV) testing in cervical screening is usually performed on physician-taken cervical smears in liquid-based medium. However, solid-state specimen carriers allow easy, non-hazardous storage and transportation and might be suitable for self-collection by non-responders in screening and in low-resource settings. We evaluated the adequacy of self-collected cervicovaginal (c/v) samples using a Viba-brush stored on an Indicating FTA-elute cartridge (FTA-based self-sampling) for hrHPV testing in women referred to a gynecology clinic due to an abnormal smear. 182 women accepted to self-collect a c/v sample. After self-sampling, a physician obtained a conventional liquid-based cervical smear. Finally, women were examined by colposcopy and a biopsy was taken when clinically indicated. Self-samples required only simple DNA elution, and DNA was extracted from physician-obtained samples. Both samples were tested for 14 hrHPVs by GP5+/6+-EIA-LQ Test and SPF(10)-DEIA-LiPA(25). Both assays detected significantly more hrHPV in physician-collected specimens than in self-collected samples (75.3% and 67.6% by SPF(10); 63.3% and 53.3% by GP5+/6+, respectively). The combination of physician-collected specimen and GP5+/6+ testing demonstrated the optimal balance in sensitivity (98.0%) and specificity (48.1%) for CIN2+ detection in this referral population. A test system of FTA-based self-collection and SPF(10) hrHPV detection approached this sensitivity (95.9%) and specificity (42.9%). These results show that the clinical performance of hrHPV detection is determined by both the sample collection system and the test method. FTA-based self-collection with SPF(10) testing might be valuable when a liquid-based medium cannot be used, but requires further investigation in screening populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Dangerous compounds in the dredged material from the sea - Assessment of the current approach to the evaluation of contaminations based on the data from the Polish coastal zone (the Baltic Sea).

    PubMed

    Staniszewska, Marta; Boniecka, Helena

    2018-05-01

    It has been shown that the current approach to the assessment of contamination in the sediments obtained during the dredging works in the Baltic countries indicates the presence of "non-contaminated" dredged material. The concentration limits of heavy metals, Polycyclic Aromatic Hydrocarbons (PAHs), Polychlorinated Biphenyls (PCBs) have been exceeded only in 1% of the samples obtained during the dredging works (2005-2015) within the Polish coastal zone. After 2008, no contaminated sediments have been found. Also, in the remaining Baltic countries, sediments are very rarely contaminated. As a result of this assessment, the sediments can be stored in the sea or have a practical application. However, it has been questioned whether the large cost of determining the numerous chemical parameters is justified. It has been proposed to carry out simple screening tests. Following the preliminary screening, the decision on more detailed (and expensive) chemical tests of individual pollutants would be made. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Interval timing in genetically modified mice: a simple paradigm

    PubMed Central

    Balci, F.; Papachristos, E. B.; Gallistel, C. R.; Brunner, D.; Gibson, J.; Shumyatsky, G. P.

    2009-01-01

    We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using D-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently. PMID:17696995

  18. Interval timing in genetically modified mice: a simple paradigm.

    PubMed

    Balci, F; Papachristos, E B; Gallistel, C R; Brunner, D; Gibson, J; Shumyatsky, G P

    2008-04-01

    We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using d-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently.

  19. Psychometric Properties of Brief Screening Tests for Alcohol Use Disorders during Pregnancy in Argentina.

    PubMed

    López, Mariana Beatriz; Lichtenberger, Aldana; Conde, Karina; Cremonte, Mariana

    2017-07-01

    Background  Considering the physical, mental and behavioral problems related to fetal alcohol exposure, prenatal clinical guides suggest a brief evaluation of alcohol consumption during pregnancy to detect alcohol intake and to adjust interventions, if required. Even if any alcohol use should be considered risky during pregnancy, identifying women with alcohol use disorders is important because they could need a more specific intervention than simple advice to abstain. Most screening tests have been developed and validated in male populations and focused on the long-term consequences of heavy alcohol use, so they might be inappropriate to assess consumption in pregnant women. Objective  To analyze the internal reliability and validity of the alcohol screening instruments Alcohol Use Disorders Identification Test (AUDIT), Alcohol Use Disorders Identification Test - Consumption (AUDIT-C), Tolerance, Worried, Eye-Opener, Amnesia and Cut-Down (TWEAK), Rapid Alcohol Problems Screen - Quantity Frequency (RAPS-QF) and Tolerance, Annoyed, Cut-Down and Eye-Opener (T-ACE) to identify alcohol use disorders in pregnant women. Methods  A total of 641 puerperal women were personally interviewed during the 48 hours after delivery. The receiver operating characteristics (ROC) curves and the sensitivity and specificity of each instrument using different cut-off points were analyzed. Results  All instruments showed areas under the ROC curves above 0.80. Larger areas were found for the TWEAK and the AUDIT. The TWEAK, the T-ACE and the AUDIT-C showed higher sensitivity, while the AUDIT and the RAPS-QF showed higher specificity. Reliability (internal consistency) was low for all instruments, improving when optimal cut-off points were used, especially for the AUDIT, the AUDIT-C and the RAPS-QF. Conclusions  In other cultural contexts, studies have concluded that T-ACE and TWEAK are the best instruments to assess pregnant women. In contrast, our results evidenced the low reliability of those instruments and a better performance of the AUDIT in this population. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  20. Accessing Autonomic Function Can Early Screen Metabolic Syndrome

    PubMed Central

    Dai, Meng; Li, Mian; Yang, Zhi; Xu, Min; Xu, Yu; Lu, Jieli; Chen, Yuhong; Liu, Jianmin; Ning, Guang; Bi, Yufang

    2012-01-01

    Background Clinical diagnosis of the metabolic syndrome is time-consuming and invasive. Convenient instruments that do not require laboratory or physical investigation would be useful in early screening individuals at high risk of metabolic syndrome. Examination of the autonomic function can be taken as a directly reference and screening indicator for predicting metabolic syndrome. Methodology and Principal Findings The EZSCAN test, as an efficient and noninvasive technology, can access autonomic function through measuring electrochemical skin conductance. In this study, we used EZSCAN value to evaluate autonomic function and to detect metabolic syndrome in 5,887 participants aged 40 years or older. The EZSCAN test diagnostic accuracy was analyzed by receiver operating characteristic curves. Among the 5,815 participants in the final analysis, 2,541 were diagnosed as metabolic syndrome and the overall prevalence was 43.7%. Prevalence of the metabolic syndrome increased with the elevated EZSCAN risk level (p for trend <0.0001). Moreover, EZSCAN value was associated with an increase in the number of metabolic syndrome components (p for trend <0.0001). Compared with the no risk group (EZSCAN value 0–24), participants at the high risk group (EZSCAN value: 50–100) had a 2.35 fold increased risk of prevalent metabolic syndrome after the multiple adjustments. The area under the curve of the EZSCAN test was 0.62 (95% confidence interval [CI], 0.61–0.64) for predicting metabolic syndrome. The optimal operating point for the EZSCAN value to detect a high risk of prevalent metabolic syndrome was 30 in this study, while the sensitivity and specificity were 71.2% and 46.7%, respectively. Conclusions and Significance In conclusion, although less sensitive and accurate when compared with the clinical definition of metabolic syndrome, we found that the EZSCAN test is a good and simple screening technique for early predicting metabolic syndrome. PMID:22916265

  1. Aiding alternatives assessment with an uncertainty-tolerant hazard scoring method.

    PubMed

    Faludi, Jeremy; Hoang, Tina; Gorman, Patrick; Mulvihill, Martin

    2016-11-01

    This research developed a single-score system to simplify and clarify decision-making in chemical alternatives assessment, accounting for uncertainty. Today, assessing alternatives to hazardous constituent chemicals is a difficult task-rather than comparing alternatives by a single definitive score, many independent toxicological variables must be considered at once, and data gaps are rampant. Thus, most hazard assessments are only comprehensible to toxicologists, but business leaders and politicians need simple scores to make decisions. In addition, they must balance hazard against other considerations, such as product functionality, and they must be aware of the high degrees of uncertainty in chemical hazard data. This research proposes a transparent, reproducible method to translate eighteen hazard endpoints into a simple numeric score with quantified uncertainty, alongside a similar product functionality score, to aid decisions between alternative products. The scoring method uses Clean Production Action's GreenScreen as a guide, but with a different method of score aggregation. It provides finer differentiation between scores than GreenScreen's four-point scale, and it displays uncertainty quantitatively in the final score. Displaying uncertainty also illustrates which alternatives are early in product development versus well-defined commercial products. This paper tested the proposed assessment method through a case study in the building industry, assessing alternatives to spray polyurethane foam insulation containing methylene diphenyl diisocyanate (MDI). The new hazard scoring method successfully identified trade-offs between different alternatives, showing finer resolution than GreenScreen Benchmarking. Sensitivity analysis showed that different weighting schemes in hazard scores had almost no effect on alternatives ranking, compared to uncertainty from data gaps. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A novel immunochromatographic electrochemical biosensor for highly sensitive and selective detection of trichloropyridinol, a biomarker of exposure to chlorpyrifos.

    PubMed

    Wang, Limin; Lu, Donglai; Wang, Jun; Du, Dan; Zou, Zhexiang; Wang, Hua; Smith, Jordan N; Timchalk, Charles; Liu, Fengquan; Lin, Yuehe

    2011-02-15

    We present a novel portable immunochromatographic electrochemical biosensor (IEB) for simple, rapid, and sensitive biomonitoring of trichloropyridinol (TCP), a metabolite biomarker of exposure to organophosphorus insecticides. Our new approach takes the advantage of immunochromatographic test strip for a rapid competitive immunoreaction and a disposable screen-printed carbon electrode for a rapid and sensitive electrochemical analysis of captured HRP labeling. Several key experimental parameters (e.g. immunoreaction time, the amount of HRP labeled TCP, concentration of the substrate for electrochemical measurements, and the blocking agents for the nitrocellulose membrane) were optimized to achieve a high sensitivity, selectivity and stability. Under optimal conditions, the IEB has demonstrated a wide linear range (0.1-100 ng/ml) with a detection limit as low as 0.1 ng/ml TCP. Furthermore, the IEB has been successfully applied for biomonitoring of TCP in the rat plasma samples with in vivo exposure to organophosphorus insecticides like Chlorpyrifos-oxon (CPF-oxon). The IEB thus opens up new pathways for designing a simple, rapid, clinically accurate, and quantitative tool for TCP detection, as well as holds a great promise for in-field screening of metabolite biomarkers, e.g., TCP, for humans exposed to organophosphorus insecticides. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Development of a Pitch Discrimination Screening Test for Preschool Children.

    PubMed

    Abramson, Maria Kulick; Lloyd, Peter J

    2016-04-01

    There is a critical need for tests of auditory discrimination for young children as this skill plays a fundamental role in the development of speaking, prereading, reading, language, and more complex auditory processes. Frequency discrimination is important with regard to basic sensory processing affecting phonological processing, dyslexia, measurements of intelligence, auditory memory, Asperger syndrome, and specific language impairment. This study was performed to determine the clinical feasibility of the Pitch Discrimination Test (PDT) to screen the preschool child's ability to discriminate some of the acoustic demands of speech perception, primarily pitch discrimination, without linguistic content. The PDT used brief speech frequency tones to gather normative data from preschool children aged 3 to 5 yrs. A cross-sectional study was used to gather data regarding the pitch discrimination abilities of a sample of typically developing preschool children, between 3 and 5 yrs of age. The PDT consists of ten trials using two pure tones of 100-msec duration each, and was administered in an AA or AB forced-choice response format. Data from 90 typically developing preschool children between the ages of 3 and 5 yrs were used to provide normative data. Nonparametric Mann-Whitney U-testing was used to examine the effects of age as a continuous variable on pitch discrimination. The Kruskal-Wallis test was used to determine the significance of age on performance on the PDT. Spearman rank was used to determine the correlation of age and performance on the PDT. Pitch discrimination of brief tones improved significantly from age 3 yrs to age 4 yrs, as well as from age 3 yrs to the age 4- and 5-yrs group. Results indicated that between ages 3 and 4 yrs, children's auditory discrimination of pitch improved on the PDT. The data showed that children can be screened for auditory discrimination of pitch beginning with age 4 yrs. The PDT proved to be a time efficient, feasible tool for a simple form of frequency discrimination screening in the preschool population before the age where other diagnostic tests of auditory processing disorders can be used. American Academy of Audiology.

  4. An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.

    PubMed

    Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu

    2015-10-07

    This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.

  5. Genome-scale measurement of off-target activity using Cas9 toxicity in high-throughput screens.

    PubMed

    Morgens, David W; Wainberg, Michael; Boyle, Evan A; Ursu, Oana; Araya, Carlos L; Tsui, C Kimberly; Haney, Michael S; Hess, Gaelen T; Han, Kyuho; Jeng, Edwin E; Li, Amy; Snyder, Michael P; Greenleaf, William J; Kundaje, Anshul; Bassik, Michael C

    2017-05-05

    CRISPR-Cas9 screens are powerful tools for high-throughput interrogation of genome function, but can be confounded by nuclease-induced toxicity at both on- and off-target sites, likely due to DNA damage. Here, to test potential solutions to this issue, we design and analyse a CRISPR-Cas9 library with 10 variable-length guides per gene and thousands of negative controls targeting non-functional, non-genic regions (termed safe-targeting guides), in addition to non-targeting controls. We find this library has excellent performance in identifying genes affecting growth and sensitivity to the ricin toxin. The safe-targeting guides allow for proper control of toxicity from on-target DNA damage. Using this toxicity as a proxy to measure off-target cutting, we demonstrate with tens of thousands of guides both the nucleotide position-dependent sensitivity to single mismatches and the reduction of off-target cutting using truncated guides. Our results demonstrate a simple strategy for high-throughput evaluation of target specificity and nuclease toxicity in Cas9 screens.

  6. Genome-scale measurement of off-target activity using Cas9 toxicity in high-throughput screens

    PubMed Central

    Morgens, David W.; Wainberg, Michael; Boyle, Evan A.; Ursu, Oana; Araya, Carlos L.; Tsui, C. Kimberly; Haney, Michael S.; Hess, Gaelen T.; Han, Kyuho; Jeng, Edwin E.; Li, Amy; Snyder, Michael P.; Greenleaf, William J.; Kundaje, Anshul; Bassik, Michael C.

    2017-01-01

    CRISPR-Cas9 screens are powerful tools for high-throughput interrogation of genome function, but can be confounded by nuclease-induced toxicity at both on- and off-target sites, likely due to DNA damage. Here, to test potential solutions to this issue, we design and analyse a CRISPR-Cas9 library with 10 variable-length guides per gene and thousands of negative controls targeting non-functional, non-genic regions (termed safe-targeting guides), in addition to non-targeting controls. We find this library has excellent performance in identifying genes affecting growth and sensitivity to the ricin toxin. The safe-targeting guides allow for proper control of toxicity from on-target DNA damage. Using this toxicity as a proxy to measure off-target cutting, we demonstrate with tens of thousands of guides both the nucleotide position-dependent sensitivity to single mismatches and the reduction of off-target cutting using truncated guides. Our results demonstrate a simple strategy for high-throughput evaluation of target specificity and nuclease toxicity in Cas9 screens. PMID:28474669

  7. Multiple search methods for similarity-based virtual screening: analysis of search overlap and precision

    PubMed Central

    2011-01-01

    Background Data fusion methods are widely used in virtual screening, and make the implicit assumption that the more often a molecule is retrieved in multiple similarity searches, the more likely it is to be active. This paper tests the correctness of this assumption. Results Sets of 25 searches using either the same reference structure and 25 different similarity measures (similarity fusion) or 25 different reference structures and the same similarity measure (group fusion) show that large numbers of unique molecules are retrieved by just a single search, but that the numbers of unique molecules decrease very rapidly as more searches are considered. This rapid decrease is accompanied by a rapid increase in the fraction of those retrieved molecules that are active. There is an approximately log-log relationship between the numbers of different molecules retrieved and the number of searches carried out, and a rationale for this power-law behaviour is provided. Conclusions Using multiple searches provides a simple way of increasing the precision of a similarity search, and thus provides a justification for the use of data fusion methods in virtual screening. PMID:21824430

  8. Sensitivity and Specificity of an Operon Immunochromatographic Test in Serum and Whole-Blood Samples for the Diagnosis of Trypanosoma cruzi Infection in Spain, an Area of Nonendemicity

    PubMed Central

    Flores-Chavez, María; Cruz, Israel; Nieto, Javier; Gárate, Teresa; Navarro, Miriam; Pérez-Ayala, Ana; López-Vélez, Rogelio

    2012-01-01

    Trypanosoma cruzi infection is an imported parasitic disease in Spain, and the majority of infected individuals are in the chronic phase of the disease. This study evaluated the sensitivity and specificity of the Operon immunochromatographic test (ICT-Operon; Simple Stick Chagas and Simple Chagas WB [whole blood]; Operon S.A., Spain) for different biological samples. Well-characterized serum samples were obtained from chagasic patients (n = 63), nonchagasic individuals (n = 95), visceral leishmaniasis patients (n = 38), and malaria patients (n = 55). Noncharacterized specimens were obtained from Latin American immigrants and individuals at risk with a clinical and/or epidemiological background: these specimens were recovered serum or plasma samples (n = 450), whole peripheral blood (n = 94), and capillary blood (n = 282). The concordance of the results by enzyme-linked immunosorbent assay and indirect immunofluorescence test was considered to be the “gold standard” for diagnosis. Serum and plasma samples were analyzed by Stick Chagas, and whole blood was analyzed by Simple Chagas WB. The sensitivity and specificity of the ICT-Operon in well-characterized samples were 100% and 97.9%, respectively. No cross-reactivity was found with samples obtained from visceral leishmaniasis patients. In contrast, a false-positive result was obtained in 27.3% of samples from malaria patients. The sensitivities of the rapid test in noncharacterized serum or plasma, peripheral blood, and capillary blood samples were 100%, 92.1%, and 86.4%, respectively, while the specificities were 91.6%, 93.6%, and 95% in each case. ICT-Operon showed variable sensitivity, depending on the kind of sample, performing better when serum or plasma samples were used. It could therefore be used for serological screening combined with any other conventional test. PMID:22761296

  9. Screening and brief interventions for hazardous and harmful alcohol use in probation services: a cluster randomised controlled trial protocol

    PubMed Central

    2009-01-01

    Background A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However, although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlled trial with Offender Managers (OMs) as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Methods and design Ninety-six OMs from 9 probation areas across 3 English regions (the North East Region (n = 4) and London and the South East Regions (n = 5)) will be recruited. OMs will be randomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs); 5-minute simple structured advice (n = 32 OMs) and 20-minute brief lifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs). Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ) or the Fast Alcohol Screening Test (FAST). There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months post intervention. Analysis will include client measures (screening result, weekly alcohol consumption, alcohol-related problems, re-offending, public service use and quality of life) and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention). We will also examine the practitioner and organisational factors associated with successful implementation. Discussion The trial will evaluate the impact of screening and brief alcohol intervention in routine probation work and therefore its findings will be highly relevant to probation teams and thus the criminal justice system in the UK. Ethical approval was given by Northern & Yorkshire REC Trial Registration number ISRCTN 19160244 PMID:19922618

  10. Screening and brief interventions for hazardous and harmful alcohol use in probation services: a cluster randomised controlled trial protocol.

    PubMed

    Newbury-Birch, Dorothy; Bland, Martin; Cassidy, Paul; Coulton, Simon; Deluca, Paolo; Drummond, Colin; Gilvarry, Eilish; Godfrey, Christine; Heather, Nick; Kaner, Eileen; Myles, Judy; Oyefeso, Adenekan; Parrott, Steve; Perryman, Katherine; Phillips, Tom; Shenker, Don; Shepherd, Jonathan

    2009-11-18

    A large number of randomised controlled trials in health settings have consistently reported positive effects of brief intervention in terms of reductions in alcohol use. However, although alcohol misuse is common amongst offenders, there is limited evidence of alcohol brief interventions in the criminal justice field. This factorial pragmatic cluster randomised controlled trial with Offender Managers (OMs) as the unit of randomisation will evaluate the effectiveness and cost-effectiveness of different models of screening to identify hazardous and harmful drinkers in probation and different intensities of brief intervention to reduce excessive drinking in probation clients. Ninety-six OMs from 9 probation areas across 3 English regions (the North East Region (n = 4) and London and the South East Regions (n = 5)) will be recruited. OMs will be randomly allocated to one of three intervention conditions: a client information leaflet control condition (n = 32 OMs); 5-minute simple structured advice (n = 32 OMs) and 20-minute brief lifestyle counselling delivered by an Alcohol Health Worker (n = 32 OMs). Randomisation will be stratified by probation area. To test the relative effectiveness of different screening methods all OMs will be randomised to either the Modified Single Item Screening Questionnaire (M-SASQ) or the Fast Alcohol Screening Test (FAST). There will be a minimum of 480 clients recruited into the trial. There will be an intention to treat analysis of study outcomes at 6 and 12 months post intervention. Analysis will include client measures (screening result, weekly alcohol consumption, alcohol-related problems, re-offending, public service use and quality of life) and implementation measures from OMs (the extent of screening and brief intervention beyond the minimum recruitment threshold will provide data on acceptability and feasibility of different models of brief intervention). We will also examine the practitioner and organisational factors associated with successful implementation. The trial will evaluate the impact of screening and brief alcohol intervention in routine probation work and therefore its findings will be highly relevant to probation teams and thus the criminal justice system in the UK.Ethical approval was given by Northern & Yorkshire REC. ISRCTN 19160244.

  11. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  12. FMM-Yukawa: An adaptive fast multipole method for screened Coulomb interactions

    NASA Astrophysics Data System (ADS)

    Huang, Jingfang; Jia, Jun; Zhang, Bo

    2009-11-01

    A Fortran program package is introduced for the rapid evaluation of the screened Coulomb interactions of N particles in three dimensions. The method utilizes an adaptive oct-tree structure, and is based on the new version of fast multipole method in which the exponential expansions are used to diagonalize the multipole-to-local translations. The program and its full description, as well as several closely related packages are also available at http://www.fastmultipole.org/. This paper is a brief review of the program and its performance. Catalogue identifier: AEEQ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEQ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GPL 2.0 No. of lines in distributed program, including test data, etc.: 12 385 No. of bytes in distributed program, including test data, etc.: 79 222 Distribution format: tar.gz Programming language: Fortran77 and Fortran90 Computer: Any Operating system: Any RAM: Depends on the number of particles, their distribution, and the adaptive tree structure Classification: 4.8, 4.12 Nature of problem: To evaluate the screened Coulomb potential and force field of N charged particles, and to evaluate a convolution type integral where the Green's function is the fundamental solution of the modified Helmholtz equation. Solution method: An adaptive oct-tree is generated, and a new version of fast multipole method is applied in which the "multipole-to-local" translation operator is diagonalized. Restrictions: Only three and six significant digits accuracy options are provided in this version. Unusual features: Most of the codes are written in Fortran77. Functions for memory allocation from Fortran90 and above are used in one subroutine. Additional comments: For supplementary information see http://www.fastmultipole.org/ Running time: The running time varies depending on the number of particles (denoted by N) in the system and their distribution. The running time scales linearly as a function of N for nearly uniform particle distributions. For three digits accuracy, the solver breaks even with direct summation method at about N = 750. References: [1] L. Greengard, J. Huang, A new version of the fast multipole method for screened Coulomb interactions in three dimensions, J. Comput. Phys. 180 (2002) 642-658.

  13. Weighted Feature Significance: A Simple, Interpretable Model of Compound Toxicity Based on the Statistical Enrichment of Structural Features

    PubMed Central

    Huang, Ruili; Southall, Noel; Xia, Menghang; Cho, Ming-Hsuang; Jadhav, Ajit; Nguyen, Dac-Trung; Inglese, James; Tice, Raymond R.; Austin, Christopher P.

    2009-01-01

    In support of the U.S. Tox21 program, we have developed a simple and chemically intuitive model we call weighted feature significance (WFS) to predict the toxicological activity of compounds, based on the statistical enrichment of structural features in toxic compounds. We trained and tested the model on the following: (1) data from quantitative high–throughput screening cytotoxicity and caspase activation assays conducted at the National Institutes of Health Chemical Genomics Center, (2) data from Salmonella typhimurium reverse mutagenicity assays conducted by the U.S. National Toxicology Program, and (3) hepatotoxicity data published in the Registry of Toxic Effects of Chemical Substances. Enrichments of structural features in toxic compounds are evaluated for their statistical significance and compiled into a simple additive model of toxicity and then used to score new compounds for potential toxicity. The predictive power of the model for cytotoxicity was validated using an independent set of compounds from the U.S. Environmental Protection Agency tested also at the National Institutes of Health Chemical Genomics Center. We compared the performance of our WFS approach with classical classification methods such as Naive Bayesian clustering and support vector machines. In most test cases, WFS showed similar or slightly better predictive power, especially in the prediction of hepatotoxic compounds, where WFS appeared to have the best performance among the three methods. The new algorithm has the important advantages of simplicity, power, interpretability, and ease of implementation. PMID:19805409

  14. Pathological and Sub-Clinical Problem Gambling in a New Zealand Prison: A Comparison of the Eight and SOGS Gambling Screens

    ERIC Educational Resources Information Center

    Sullivan, Sean; Brown, Robert; Skinner, Bruce

    2008-01-01

    Prison populations have been identified as having elevated levels of problem gambling prevalence, and screening for problem gambling may provide an opportunity to identify and address a behavior that may otherwise lead to re-offending. A problem gambling screen for this purpose would need to be brief, simple to score, and be able to be…

  15. Thermodynamics of Thomas-Fermi screened Coulomb systems

    NASA Technical Reports Server (NTRS)

    Firey, B.; Ashcroft, N. W.

    1977-01-01

    We obtain in closed analytic form, estimates for the thermodynamic properties of classical fluids with pair potentials of Yukawa type, with special reference to dense fully ionized plasmas with Thomas-Fermi or Debye-Hueckel screening. We further generalize the hard-sphere perturbative approach used for similarly screened two-component mixtures, and demonstrate phase separation in this simple model of a liquid mixture of metallic helium and hydrogen.

  16. Screening of marine bacterial producers of polyunsaturated fatty acids and optimisation of production.

    PubMed

    Abd El Razak, Ahmed; Ward, Alan C; Glassey, Jarka

    2014-02-01

    Water samples from three different environments including Mid Atlantic Ridge, Red Sea and Mediterranean Sea were screened in order to isolate new polyunsaturated fatty acids (PUFAs) bacterial producers especially eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA). Two hundred and fifty-one isolates were screened for PUFA production and among them the highest number of producers was isolated from the Mid-Atlantic Ridge followed by the Red Sea while no producers were found in the Mediterranean Sea samples. The screening strategy included a simple colourimetric method followed by a confirmation via GC/MS. Among the tested producers, an isolate named 66 was found to be a potentially high PUFA producer producing relatively high levels of EPA in particular. A Plackett-Burman statistical design of experiments was applied to screen a wide number of media components identifying glycerol and whey as components of a production medium. The potential low-cost production medium was optimised by applying a response surface methodology to obtain the highest productivity converting industrial by-products into value-added products. The maximum achieved productivity of EPA was 20 mg/g, 45 mg/l, representing 11% of the total fatty acids, which is approximately five times more than the amount produced prior to optimisation. The production medium composition was 10.79 g/l whey and 6.87 g/l glycerol. To our knowledge, this is the first investigation of potential bacteria PUFA producers from Mediterranean and Red Seas providing an evaluation of a colourimetric screening method as means of rapid screening of a large number of isolates.

  17. Acceptability of unsupervised HPV self-sampling using written instructions.

    PubMed

    Waller, J; McCaffery, K; Forrest, S; Szarewski, A; Cadman, L; Austin, J; Wardle, J

    2006-01-01

    The study measured the acceptability of self-sampling for human papillomavirus (HPV) testing in the context of cervical cancer screening. Women carried out self-sampling unsupervised, using a written instruction sheet. Participants were women attending either a family planning clinic or a primary care trust for routine cervical screening. Women (n = 902) carried out self-sampling for HPV testing and then a clinician did a routine cervical smear and HPV test. Immediately after having the two tests, participants completed a measure of acceptability for both tests, and answered questions about ease of using the instruction sheet and willingness to use self-sampling in the future. The majority of women found self-sampling more acceptable than the clinician-administered test, but there was a lack of confidence that the test had been done correctly. Significant demographic differences in attitudes were found, with married women having more favourable attitudes towards self-sampling than single women, and Asian women having more negative attitudes than women in other ethnic groups. Intention to use self-sampling in the future was very high across all demographic groups. Self-sampling for HPV testing was highly acceptable in this large and demographically diverse sample, and women were able to carry out the test alone, using simple written instructions. Consistent with previous studies, women were concerned about doing the test properly and this issue will need to be addressed if self-sampling is introduced. More work is needed to see whether the demographic differences we found are robust and to identify reasons for lower acceptability among single women and those from Asian background.

  18. A simple screening test for the detection of metallo-β-lactamase-producing Pseudomonas aeruginosa and Acinetobacter in a tertiary care hospital.

    PubMed

    Wan Nor Amilah, W A W; Noor Izani, N J; Ng, W K; Ashraful Haq, J

    2012-12-01

    Clinical utilization of carbapenems remains under threat with the emergence of acquired carbapenemase-producing bacteria, particularly metallo-β-lactamases (MBL). Rapid detection of MBL-producing Gram-negative bacilli is essential to prevent their widespread dissemination. However, no standardized detection method is available for routine laboratory use. The purpose of the study was to evaluate a chelating-agent based double disk synergic test and disk potentiation test for MBL-producing strain detection and to determine the isolation rate of MBL-producing Pseudomonas aeruginosa and Acinetobacter from clinical samples in our tertiary teaching hospital. A total of 22 and 66 imipenem-resistant P. aeruginosa and Acinetobacter isolates respectively were tested with ceftazidime (CAZ) disk by modified double disk synergic test and disk potentiation test using ethylenediaminetetraacetic acid (EDTA) and 2-mercaptopropionic acid (as chelating agents) to detect MBL production. The tests were compared with EDTA-phenanthroline-imipenem (EPI) microdilution MIC test as gold standard. MBL positive strains were detected in 17 (77.3%) P. aeruginosa and 2 (3.5%) Acinetobacter isolates. The disk potentiation test with 2-mercaptopropionic acid (2-MPA) dilution of 1:12 provided the most acceptable sensitivities and specificities (88.2% sensitivity and 100% specificity in P. aeruginosa; 100% sensitivity and specificity in Acinetobacter) compared to other screening methods used in this study. This study provided useful information on the local prevalence of MBL-producing P. aeruginosa and Acinetobacter in our hospital. Disc potentiation test with CAZ/2-MPA disc appears to be reliable and convenient MBL detection method in the routine clinical laboratory.

  19. Proposed low-cost premarital screening program for prevention of sickle cell and thalassemia in Yemen

    PubMed Central

    Al-Nood, Hafiz; Al-Hadi, Abdulrahman

    2013-01-01

    In Yemen, the prevalence of sickle cell trait and β-thalassemia trait are high. The aim of this premarital program is to identify sickle cell and thalassemia carrier couples in Yemen before completing marriages proposal, in order to prevent affected birth. This can be achieved by applying a low-cost premarital screening program using simple blood tests compatible with the limited health resources of the country. If microcytosis or positive sickle cell is found in both or one partner has microcytosis and the other has positive sickle cell, so their children at high risk of having sickle cell or/and thalassemia diseases. Carrier couples will be referred to genetic counseling. The outcomes of this preventive program are predicted to decrease the incidence of affected birth and reduce the health burden of these disorders. The success of this program also requires governmental, educational and religious supports. PMID:25003062

  20. Telescope Array Control System Based on Wireless Touch Screen Platform

    NASA Astrophysics Data System (ADS)

    Fu, Xia-nan; Huang, Lei; Wei, Jian-yan

    2017-10-01

    Ground-based Wide Angle Cameras (GMAC) are the ground-based observational facility for the SVOM (Space Variable Object Monitor) astronomical satellite of Sino-French cooperation, and Mini-GWAC is the pathfinder and supplement of GWAC. In the context of the Mini-GWAC telescope array, this paper introduces the design and implementation of a kind of telescope array control system based on the wireless touch screen platform. We describe the development and implementation of the system in detail in terms of control system principle, system hardware structure, software design, experiment, and test etc. The system uses a touch-control PC which is based on the Windows CE system as the upper computer, while the wireless transceiver module and PLC (Programmable Logic Controller) are taken as the system kernel. It has the advantages of low cost, reliable data transmission, and simple operation. And the control system has been applied to the Mini-GWAC successfully.

  1. Implementing a Commercial Rule Base as a Medication Order Safety Net

    PubMed Central

    Reichley, Richard M.; Seaton, Terry L.; Resetar, Ervina; Micek, Scott T.; Scott, Karen L.; Fraser, Victoria J.; Dunagan, W. Claiborne; Bailey, Thomas C.

    2005-01-01

    A commercial rule base (Cerner Multum) was used to identify medication orders exceeding recommended dosage limits at five hospitals within BJC HealthCare, an integrated health care system. During initial testing, clinical pharmacists determined that there was an excessive number of nuisance and clinically insignificant alerts, with an overall alert rate of 9.2%. A method for customizing the commercial rule base was implemented to increase rule specificity for problematic rules. The system was subsequently deployed at two facilities and achieved alert rates of less than 1%. Pharmacists screened these alerts and contacted ordering physicians in 21% of cases. Physicians made therapeutic changes in response to 38% of alerts presented to them. By applying simple techniques to customize rules, commercial rule bases can be used to rapidly deploy a safety net to screen drug orders for excessive dosages, while preserving the rule architecture for later implementations of more finely tuned clinical decision support. PMID:15802481

  2. Colon cancer screening

    MedlinePlus

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  3. A computerized stroop test for the evaluation of psychotropic drugs in healthy participants.

    PubMed

    Pilli, Raveendranadh; Naidu, Mur; Pingali, Usha Rani; Shobha, J C; Reddy, A Praveen

    2013-04-01

    The Stroop paradigm evaluates susceptibility to interference and is sensitive to dysfunction in frontal lobes and drug effects. The aim of the present study was to establish a simple and reliable computerized version of Stroop color-word test, which can be used for screening of various psychotropic drugs. The standardized method was followed in all cases, by recording the reaction time (RT) in msec in 24 healthy participants using computerized version of Stroop color-word test. Reproducibility of the test procedure was evaluated by recording the RTs by a single experimenter on two sessions (interday reproducibility). Validity of the model was further tested by evaluating the psychotropic effect of Zolpidem 5 mg, Caffeine 500 mg, or Placebo on 24 healthy subjects in a randomized, double blind three-way crossover design. The method was found to produce low variability with coefficient of variation less than 10%. Interday reproducibility was very good as shown by Bland-Altman plot with most of the values within ±2SD. There was a significant increase in RTs in Stroop performance with Zolpidem at 1 hr and 2 hrs; in contrast, caffeine significantly decreased RTs in Stroop performance at 1 hr only compared to placebo. The Stroop color-word recording and analysis system is simple, sensitive to centrally acting drug effects, and has potential for future experimental psychomotor assessment studies.

  4. Development of PCR for screening of enteroaggregative Escherichia coli.

    PubMed Central

    Schmidt, H; Knop, C; Franke, S; Aleksic, S; Heesemann, J; Karch, H

    1995-01-01

    In this study, we determined the sequence of the EcoRI-PstI fragment of the plasmid pCVD432, also termed the enteroaggregative Escherichia coli (EAggEC) probe. A primer pair complementary to this probe was designed for PCR amplification of a 630-bp region. Comparison of the analysis of the EAggEC probe sequence with those in database libraries revealed no significant similarity to any known bacterial gene. Pure cultures of E. coli cells, as well as mixed cultures from stool specimens, were investigated with the PCR assay, the EAggEC probe test, and the adherence test. Of 50 E. coli strains which demonstrated aggregative adherence to HEp-2 cells, 43 (86%) were positive with the EAggEC PCR. All 43 of these strains reacted with the EAggEC probe. Six EAggEC strains gave negative results by both molecular techniques. In contrast, only 4 of 418 (0.96%) strains representing other categories of diarrheagenic E. coli demonstrated a positive PCR result. The PCR was also successful in screening for the presence of EAggEC in enriched cultures grown from stool specimens. Compared with cell culture assays and colony hybridization, our findings revealed that the PCR assay was more rapid, simple, and highly sensitive and can therefore be recommended as a screening method for EAggEC in the clinical laboratory. PMID:7751380

  5. Characterizing hydraulic conductivity with the direct-push permeameter

    USGS Publications Warehouse

    Butler, J.J.; Dietrich, P.; Wittig, V.; Christy, T.

    2007-01-01

    The direct-push permeameter (DPP) is a promising approach for obtaining high-resolution information about vertical variations in hydraulic conductivity (K) in shallow unconsolidated settings. This small-diameter tool, which consists of a short screened section with a pair of transducers inset in the tool near the screen, is pushed into the subsurface to a depth at which a K estimate is desired. A short hydraulic test is then performed by injecting water through the screen at a constant rate (less than 4 L/min) while pressure changes are monitored at the transducer locations. Hydraulic conductivity is calculated using the injection rate and the pressure changes in simple expressions based on Darcy's Law. In units of moderate or higher hydraulic conductivity (more than 1 m/d), testing at a single level can be completed within 10 to 15 min. Two major advantages of the method are its speed and the insensitivity of the K estimates to the zone of compaction created by tool advancement. The potential of the approach has been assessed at two extensively studied sites in the United States and Germany over a K range commonly faced in practical field investigations (0.02 to 500 m/d). The results of this assessment demonstrate that the DPP can provide high-resolution K estimates that are in good agreement with estimates obtained through other means. ?? 2007 National Ground Water Association.

  6. New method of paired thyrotropin assay as a screening test for neonatal hypothyroidism. [/sup 125/I tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyai, K.; Oura, T.; Kawashima, M.

    1978-11-01

    A simple and reliable method of paired TSH assay was developed and used in screening for neonatal primary hypothyroidism. In this method, a paired assay is first done. Equal parts of the extracts of dried blood spots on filter paper (9 mm diameter) from two infants 4 to 7 days old are combined and assayed for TSH by double antibody RIA. If the value obtained is over the cut-off point, the extracts are assayed separately for TSH in a second assay to identify the abnormal sample. Two systems, A and B, with different cut-off points were tested. On the basismore » of reference blood samples (serum levels of TSH, 80 ..mu..U/ml in system A and 40 ..mu..U/ml in system B), the cut-off point was selected as follows: upper 5 (A) or 4 (B) percentile in the paired assay and values of reference blood samples in the second individual assay. Four cases (2 in A and 2 in B) of neonatal primary hypothyroidism were found among 25 infants (23 in A and 2 in B) who were recalled from a general population of 41,400 infants (24,200 in A and 17,200 in B) by 22,700 assays. This paired TSH assay system saves labor and expense for screening neonatal hypothyroidism.« less

  7. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    PubMed

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  8. Hybrid nanosensor for colorimetric and ultrasensitive detection of nuclease contaminations

    NASA Astrophysics Data System (ADS)

    Cecere, Paola; Valentini, Paola; Pompa, Pier Paolo

    2016-04-01

    Nucleases are ubiquitous enzymes that degrade DNA or RNA, thus they can prejudice the good outcome of molecular biology experiments involving nucleic acids. We propose a colorimetric test for the naked-eye detection of nuclease contaminations. The system uses an hybrid nanosensor, based on gold nanoparticles functionalized with DNA probes. Our assay is rapid, instrument-free, simple and low-cost. Moreover, it reaches sensitivity equal or better than those of commercial kits, and presents a lot of advantageous aspects. Therefore, it is very competitive, with a real market potential. This test will be relevant in routine process monitoring in scientific laboratories, and in quality control in clinical laboratories and industrial processes, allowing the simultaneous detection of nucleases with different substrate specificities and large-scale screening.

  9. Performance on the Functional Movement Screen Is Related to Hop Performance But Not to Hip and Knee Strength in Collegiate Football Players.

    PubMed

    Willigenburg, Nienke; Hewett, Timothy E

    2017-03-01

    To define the relationship between Functional Movement Screen (FMS) scores and hop performance, hip strength, and knee strength in collegiate football players. Cross-sectional cohort. Freshmen of a Division I collegiate American football team (n = 59). The athletes performed the FMS, and also a variety of hop tests, isokinetic knee strength, and isometric hip strength tasks. We recorded total FMS score, peak strength, and hop performance, and we calculated asymmetries between legs on the different tasks. Spearman correlation coefficients quantified the relationships between these measures, and χ analyses compared the number of athletes with asymmetries on the different tasks. We observed significant correlations (r = 0.38-0.56, P ≤ 0.02) between FMS scores and hop distance but not between FMS scores and hip or knee strength (all P ≥ 0.21). The amount of asymmetry on the FMS test was significantly correlated to the amount of asymmetry on the timed 6-m hop (r = 0.44, P < 0.01) but not to hip or knee strength asymmetries between limbs (all P ≥ 0.34). Functional Movement Screen score was positively correlated to hop distance, and limb asymmetry in FMS tasks was correlated to limb asymmetry in 6-m hop time in football players. No significant correlations were observed between FMS score and hip and knee strength or between FMS asymmetry and asymmetries in hip and knee strength between limbs. These results indicate that a simple hop for distance test may be a time-efficient and cost-efficient alternative to FMS testing in athletes and that functional asymmetries between limbs do not coincide with strength asymmetries.

  10. A method to screen and evaluate tissue adhesives for joint repair applications

    PubMed Central

    2012-01-01

    Background Tissue adhesives are useful means for various medical procedures. Since varying requirements cause that a single adhesive cannot meet all needs, bond strength testing remains one of the key applications used to screen for new products and study the influence of experimental variables. This study was conducted to develop an easy to use method to screen and evaluate tissue adhesives for tissue engineering applications. Method Tissue grips were designed to facilitate the reproducible production of substrate tissue and adhesive strength measurements in universal testing machines. Porcine femoral condyles were used to generate osteochondral test tissue cylinders (substrates) of different shapes. Viability of substrates was tested using PI/FDA staining. Self-bonding properties were determined to examine reusability of substrates (n = 3). Serial measurements (n = 5) in different operation modes (OM) were performed to analyze the bonding strength of tissue adhesives in bone (OM-1) and cartilage tissue either in isolation (OM-2) or under specific requirements in joint repair such as filling cartilage defects with clinical applied fibrin/PLGA-cell-transplants (OM-3) or tissues (OM-4). The efficiency of the method was determined on the basis of adhesive properties of fibrin glue for different assembly times (30 s, 60 s). Seven randomly generated collagen formulations were analyzed to examine the potential of method to identify new tissue adhesives. Results Viability analysis of test tissue cylinders revealed vital cells (>80%) in cartilage components even 48 h post preparation. Reuse (n = 10) of test substrate did not significantly change adhesive characteristics. Adhesive strength of fibrin varied in different test settings (OM-1: 7.1 kPa, OM-2: 2.6 kPa, OM-3: 32.7 kPa, OM-4: 30.1 kPa) and was increasing with assembly time on average (2.4-fold). The screening of the different collagen formulations revealed a substance with significant higher adhesive strength on cartilage (14.8 kPa) and bone tissue (11.8 kPa) compared to fibrin and also considerable adhesive properties when filling defects with cartilage tissue (23.2 kPa). Conclusion The method confirmed adhesive properties of fibrin and demonstrated the dependence of adhesive properties and applied settings. Furthermore the method was suitable to screen for potential adhesives and to identify a promising candidate for cartilage and bone applications. The method can offer simple, replicable and efficient evaluation of adhesive properties in ex vivo specimens and may be a useful supplement to existing methods in clinical relevant settings. PMID:22984926

  11. Screening tests for assessing the anaerobic biodegradation of pollutant chemicals in subsurface environments

    USGS Publications Warehouse

    Suflita, Joseph M.; Concannon, Frank

    1995-01-01

    Screening methods were developed to assess the susceptibility of ground water contaminants to anaerobic biodegradation. One method was an extrapolation of a procedure previously used to measure biodegradation activity in dilute sewage sludge. Aquifer solids and ground water with no additional nutritive media were incubated anaerobically in 160-ml serum bottles containing 250 mg·l−1 carbon of the substrate of interest. This method relied on the detection of gas pressure or methane production in substrateamended microcosms relative to background controls. Other screening procedures involved the consumption of stoichiometrically required amounts of sulfate or nitrate from the same type of incubations. Close agreement was obtained between the measured and calculated amounts of substrate bioconversion based on the measured biogas pressure in methanogenic microcosms. Storage of the microcosms for up to 6 months did not adversely influence the onset or rate of benzoic acid mineralization. The lower detection limits of the methanogenic assay were found to be a function of the size of the microcosm headspace, the mean oxidation state of the substrate carbon, and the method used to correct for background temperature fluctuations. Using these simple screening procedures, biodegradation information of regulatory interest could be generated, including, (i) the length of the adaptation period, (ii) the rate of substrate decay and (iii) the completeness of the bioconversion.

  12. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs).

    PubMed

    Feng, Jiawang; Tang, Shiming; Liu, Lideng; Kuang, Xiaoshan; Wang, Xiaoyu; Hu, Songnan; You, Shuzhu

    2015-03-01

    Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.

  13. Rapid screening of tannase producing microbes by using natural tannin

    PubMed Central

    Jana, Arijit; Maity, Chiranjit; Halder, Suman Kumar; Pati, Bikas Ranjan; Mondal, Keshab Chandra; Mohapatra, Pradeep Kumar Das

    2012-01-01

    Use of natural tannin in the screening of tannase producing microbes is really promising. The present work describes about the possibility and integrity of the newly formulated method over the previously reported methods. Tannin isolated from Terminalia belerica Roxb. (Bahera) was used to differentiate between tanninolytic and nontanninolytic microbes. The method is simple, sensitive and superior for the rapid screening and isolation of tannase-producing microbes. PMID:24031931

  14. Rapid screening of tannase producing microbes by using natural tannin.

    PubMed

    Jana, Arijit; Maity, Chiranjit; Halder, Suman Kumar; Pati, Bikas Ranjan; Mondal, Keshab Chandra; Mohapatra, Pradeep Kumar Das

    2012-07-01

    Use of natural tannin in the screening of tannase producing microbes is really promising. The present work describes about the possibility and integrity of the newly formulated method over the previously reported methods. Tannin isolated from Terminalia belerica Roxb. (Bahera) was used to differentiate between tanninolytic and nontanninolytic microbes. The method is simple, sensitive and superior for the rapid screening and isolation of tannase-producing microbes.

  15. Lyin’ Eyes: Ocular-motor Measures of Reading Reveal Deception

    PubMed Central

    Cook, Anne E.; Hacker, Douglas J.; Webb, Andrea K.; Osher, Dahvyn; Kristjansson, Sean; Woltz, Dan J.; Kircher, John C.

    2013-01-01

    Our goal was to evaluate an alternative to current methods for detecting deception in security screening contexts. We evaluated a new cognitive-based test of deception that measured participants’ ocular-motor responses (pupil responses and reading behaviors) while they read and responded to statements on a computerized questionnaire. In Experiment 1, participants from a university community were randomly assigned to either a “guilty” group that committed one of two mock crimes or an “innocent” group that only learned about the crime. Participants then reported for testing, where they completed the computer-administered questionnaire that addressed their possible involvement in the crimes. Experiment 2 also manipulated participants’ incentive to pass the test and difficulty of statements on the test. In both experiments, guilty participants had increased pupil responses to statements answered deceptively; however, they spent less time fixating on, reading, and re-reading those statements than statements answered truthfully. These ocular-motor measures were optimally weighted in a discrimination function that correctly classified 85% of participants as either guilty or innocent. Findings from Experiment 2 indicated that group discrimination was improved with greater incentives to pass the test and the use of statements with simple syntax. The present findings suggest that two cognitive processes are involved in deception -- vigilance and strategy -- and that these processes are reflected in different ocular-motor measures. The ocular-motor test reported here represents a new approach to detecting deception that may fill an important need in security screening contexts. PMID:22545928

  16. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    PubMed

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Development of a framework to improve the process of recruitment to randomised controlled trials (RCTs): the SEAR (Screened, Eligible, Approached, Randomised) framework.

    PubMed

    Wilson, Caroline; Rooshenas, Leila; Paramasivan, Sangeetha; Elliott, Daisy; Jepson, Marcus; Strong, Sean; Birtle, Alison; Beard, David J; Halliday, Alison; Hamdy, Freddie C; Lewis, Rebecca; Metcalfe, Chris; Rogers, Chris A; Stein, Robert C; Blazeby, Jane M; Donovan, Jenny L

    2018-01-19

    Research has shown that recruitment to trials is a process that stretches from identifying potentially eligible patients, through eligibility assessment, to obtaining informed consent. The length and complexity of this pathway means that many patients do not have the opportunity to consider participation. This article presents the development of a simple framework to document, understand and improve the process of trial recruitment. Eight RCTs integrated a QuinteT Recruitment Intervention (QRI) into the main trial, feasibility or pilot study. Part of the QRI required mapping the patient recruitment pathway using trial-specific screening and recruitment logs. A content analysis compared the logs to identify aspects of the recruitment pathway and process that were useful in monitoring and improving recruitment. Findings were synthesised to develop an optimised simple framework that can be used in a wide range of RCTs. The eight trials recorded basic information about patients screened for trial participation and randomisation outcome. Three trials systematically recorded reasons why an individual was not enrolled in the trial, and further details why they were not eligible or approached, or declined randomisation. A framework to facilitate clearer recording of the recruitment process and reasons for non-participation was developed: SEAR - Screening, to identify potentially eligible trial participants; Eligibility, assessed against the trial protocol inclusion/exclusion criteria; Approach, the provision of oral and written information and invitation to participate in the trial, and Randomised or not, with the outcome of randomisation or treatment received. The SEAR framework encourages the collection of information to identify recruitment obstacles and facilitate improvements to the recruitment process. SEAR can be adapted to monitor recruitment to most RCTs, but is likely to add most value in trials where recruitment problems are anticipated or evident. Further work to test it more widely is recommended.

  18. Simple Tests for Rapid Detection of Canine Parvovirus Antigen and Canine Parvovirus-Specific Antibodies▿ †

    PubMed Central

    Marulappa, Shashidhara Y.; Kapil, Sanjay

    2009-01-01

    Canine parvovirus (CPV) is the number one viral cause of enteritis, morbidity, and mortality in 8-week-old young puppies. We have developed twin assays (slide agglutination test [SAT] for CPV antigen and slide inhibition test [SIT] for CPV antibody) that are sensitive, specific, cost-effective, generic for all genotypes of CPV, and provide instant results for CPV antigen detection in feces and antibody quantification in serum. We found these assays to be useful for routine applications in kennels with large numbers of puppies at risk. The results of these assays are available in 1 min and do not require any special instrumentation. SAT-SIT technology will find applications in rapid screening of samples for other hemagglutinating emerging viruses of animals and humans (influenza virus and severe acute respiratory syndrome coronavirus). PMID:18987166

  19. [Detection of the level of antibodies against bovine leucosis virus in the cow milk by immune sensor].

    PubMed

    Pyrohova, L V; Starodub, M F; Nahaeva, L I

    2005-01-01

    An immune sensor based on the surface plasmon resonance (SPR) was developed for express diagnostics of bovine leucosis. Sensor used for detection of the level of antibodies against bovine leukaemia virus (BLV) in the milk serum. It was shown that immune sensor analysis is more sensitive, rapid and simple in comparison with the traditional AGID test. It was stated that the developed immune sensor may be used for performance of screening of bovine leucosis at the farms and the minimal dilution of the milk serum should be 1:20.

  20. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  1. Microfluidic device for novel breast cancer screening by blood test using miRNA beacon probe.

    PubMed

    Salim, Bindu; Athira, M V; Kandaswamy, A; Vijayakumar, Madhulika; Saravanan, T; Sairam, Thiagarajan

    2017-09-30

    Breast cancer is identified as the highest cause of death in women suffering from cancer. Early diagnosis is the key to increase the survival of breast cancer victims. Molecular diagnosis using biomarkers have advanced much in the recent years. The cost involved in such diagnosis is not affordable for most of the population. The concept being investigated here is to realize a simple diagnosis system for screening cancer by way of a blood test utilizing a miRNA based biomarker with a complementary molecular beacon probe. A microfluidic platform was designed and attached with a fluorescence reader, which is portable and cost effective. Experiments were performed with 51 blood samples of which 30 were healthy and 21 were positive for breast cancer, collected against institutional human ethical clearance, IHEC 16/180-7-9-2016. miRNA 21 was chosen as the biomarker because it is overexpressed 4-fold in the serum of breast cancer patients. This work involved design of an experiment to prove the concept of miRNA over expression followed by detection of miRNA 21 using the microfluidic platform attached with a fluorescence reader and validation of the results using quantitative Real Time Polymerase Chain Reaction (qRT-PCR). The results obtained from the microfluidic device concurred with qRT-PCR results. The device is suitable for point-of-care application in a mass-screening programme. The study also has revealed that the stage of the cancer could be indicated by this test, which will be further useful for deciding a therapeutic regime.

  2. Touch Screen Tablets and Emergent Literacy

    ERIC Educational Resources Information Center

    Neumann, Michelle M.; Neumann, David L.

    2014-01-01

    The use of touch screen tablets by young children is increasing in the home and in early childhood settings. The simple tactile interface and finger-based operating features of tablets may facilitate preschoolers' use of tablet application software and support their educational development in domains such as literacy. This article reviews…

  3. Electrochemical Study and Determination of Electroactive Species with Screen-Printed Electrodes

    ERIC Educational Resources Information Center

    Martín-Yerga, Daniel; Costa Rama, Estefanía; Costa García, Agustín

    2016-01-01

    A lab appropriate to introduce voltammetric techniques and basic electrochemical parameters is described in this work. It is suitable to study theoretical concepts of electrochemistry in an applied way for analytical undergraduate courses. Two electroactive species, hexaammineruthenium and dopamine, are used as simple redox systems. Screen-printed…

  4. Effect of solar loading on greenhouse containers used in transpiration efficiency screening

    USDA-ARS?s Scientific Manuscript database

    Earlier we described a simple high throughput method of screening sorghum for transpiration efficiency (TE). Subsequently it was observed that while results were consistent between lines exhibiting high and low TE, ranking between lines with similar TE was variable. We hypothesized that variable mic...

  5. Development and Interlaboratory Validation of a Simple Screening Method for Genetically Modified Maize Using a ΔΔC(q)-Based Multiplex Real-Time PCR Assay.

    PubMed

    Noguchi, Akio; Nakamura, Kosuke; Sakata, Kozue; Sato-Fukuda, Nozomi; Ishigaki, Takumi; Mano, Junichi; Takabatake, Reona; Kitta, Kazumi; Teshima, Reiko; Kondo, Kazunari; Nishimaki-Mogami, Tomoko

    2016-04-19

    A number of genetically modified (GM) maize events have been developed and approved worldwide for commercial cultivation. A screening method is needed to monitor GM maize approved for commercialization in countries that mandate the labeling of foods containing a specified threshold level of GM crops. In Japan, a screening method has been implemented to monitor approved GM maize since 2001. However, the screening method currently used in Japan is time-consuming and requires generation of a calibration curve and experimental conversion factor (C(f)) value. We developed a simple screening method that avoids the need for a calibration curve and C(f) value. In this method, ΔC(q) values between the target sequences and the endogenous gene are calculated using multiplex real-time PCR, and the ΔΔC(q) value between the analytical and control samples is used as the criterion for determining analytical samples in which the GM organism content is below the threshold level for labeling of GM crops. An interlaboratory study indicated that the method is applicable independently with at least two models of PCR instruments used in this study.

  6. The West Midlands breast cancer screening status algorithm - methodology and use as an audit tool.

    PubMed

    Lawrence, Gill; Kearins, Olive; O'Sullivan, Emma; Tappenden, Nancy; Wallis, Matthew; Walton, Jackie

    2005-01-01

    To illustrate the ability of the West Midlands breast screening status algorithm to assign a screening status to women with malignant breast cancer, and its uses as a quality assurance and audit tool. Breast cancers diagnosed between the introduction of the National Health Service [NHS] Breast Screening Programme and 31 March 2001 were obtained from the West Midlands Cancer Intelligence Unit (WMCIU). Screen-detected tumours were identified via breast screening units, and the remaining cancers were assigned to one of eight screening status categories. Multiple primaries and recurrences were excluded. A screening status was assigned to 14,680 women (96% of the cohort examined), 110 cancers were not registered at the WMCIU and the cohort included 120 screen-detected recurrences. The West Midlands breast screening status algorithm is a robust simple tool which can be used to derive data to evaluate the efficacy and impact of the NHS Breast Screening Programme.

  7. Bacteria-powered battery on paper.

    PubMed

    Fraiwan, Arwa; Choi, Seokheun

    2014-12-21

    Paper-based devices have recently emerged as simple and low-cost paradigms for fluid manipulation and analytical/clinical testing. However, there are significant challenges in developing paper-based devices at the system level, which contain integrated paper-based power sources. Here, we report a microfabricated paper-based bacteria-powered battery that is capable of generating power from microbial metabolism. The battery on paper showed a very short start-up time relative to conventional microbial fuel cells (MFCs); paper substrates eliminated the time traditional MFCs required to accumulate and acclimate bacteria on the anode. Only four batteries connected in series provided desired values of current and potential to power an LED for more than 30 minutes. The battery featured (i) a low-cost paper-based proton exchange membrane directly patterned on commercially available parchment paper and (ii) paper reservoirs for holding the anolyte and the catholyte for an extended period of time. Based on this concept, we also demonstrate the use of paper-based test platforms for the rapid characterization of electricity-generating bacteria. This paper-based microbial screening tool does not require external pumps/tubings and represents the most rapid test platform (<50 min) compared with the time needed by using traditional screening tools (up to 103 days) and even recently proposed MEMS arrays (< 2 days).

  8. Development and evaluation of a magnetic immunochromatographic test to detect Taenia solium, which causes taeniasis and neurocysticercosis in humans.

    PubMed

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N; Dong, X Fan; Laborde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E; Garcia, Hector H; Gilman, Robert H; Tsang, Victor C W; Wilkins, Patricia P

    2010-04-01

    Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis.

  9. A Simple, High-Throughput Assay for Fragile X Expanded Alleles Using Triple Repeat Primed PCR and Capillary Electrophoresis

    PubMed Central

    Lyon, Elaine; Laver, Thomas; Yu, Ping; Jama, Mohamed; Young, Keith; Zoccoli, Michael; Marlowe, Natalia

    2010-01-01

    Population screening has been proposed for Fragile X syndrome to identify premutation carrier females and affected newborns. We developed a PCR-based assay capable of quickly detecting the presence or absence of an expanded FMR1 allele with high sensitivity and specificity. This assay combines a triplet repeat primed PCR with high-throughput automated capillary electrophoresis. We evaluated assay performance using archived samples sent for Fragile X diagnostic testing representing a range of Fragile X CGG-repeat expansions. Two hundred five previously genotyped samples were tested with the new assay. Data were analyzed for the presence of a trinucleotide “ladder” extending beyond 55 repeats, which was set as a cut-off to identify expanded FMR1 alleles. We identified expanded FMR1 alleles in 132 samples (59 premutation, 71 full mutation, 2 mosaics) and normal FMR1 alleles in 73 samples. We found 100% concordance with previous results from PCR and Southern blot analyses. In addition, we show feasibility of using this assay with DNA extracted from dried-blood spots. Using a single PCR combined with high-throughput fragment analysis on the automated capillary electrophoresis instrument, we developed a rapid and reproducible PCR-based laboratory assay that meets many of the requirements for a first-tier test for population screening. PMID:20431035

  10. Relationships Between Simple Toe Elevation Angle in the Standing Position and Dynamic Balance and Fall Risk Among Community-Dwelling Older Adults.

    PubMed

    Takatori, Katsuhiko; Matsumoto, Daisuke

    2015-10-01

    To investigate the relationships between toe elevation ability in the standing position and dynamic balance and fall risk among community-dwelling older adults. Cross-sectional survey. General community. Community-dwelling older adults (N = 287). Toe elevation angles in the standing position. Intra-rater and inter-rater reliability of measurements of the toe elevation angle was high (internal coefficient of correlation [ICC] (1,2) = 0.94 for the former and ICC (2,1) = 0.90 for the latter). Significant correlations were found between the toe elevation angle and age (r = -0.20, P < .01), 5-m walking time (r = -0.31, P < .01), Functional Reach Test (r = 0.36, P < .01), Timed Up and Go Test (r = -0.36, P < .01), and Chair Stand Test (r = 0.26, P < .01). Subjects who experienced a fall in the previous 6 months had a significantly lower toe elevation angle compared with subjects who did not experience a fall (t = 2.19, P < .05). Multiple regression analysis revealed that results of the Functional Reach Test (β = .22, P < .001) and Timed Up and Go Test (β = -0.74, P < .001) were significantly associated with the toe elevation angle. Toe elevation angle was an index of dynamic balance ability and appears to be a simple screening test for fall risk in community-dwelling older adults. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. Measurement of urinary metanephrines to screen for pheochromocytoma in an unselected hospital referral population.

    PubMed

    Brain, Keith L; Kay, Jonathan; Shine, Brian

    2006-11-01

    Despite the rarity of pheochromocytoma, diagnosis is important because of the dangers of uncontrolled severe hypertension and the availability of very effective surgical treatment. Urinary or plasma catecholamines or catecholamine derivatives are commonly used to screen for pheochromocytomas before imaging, but data from 24-h urinary metanephrine results, patient age, and sex may better predict tumors in populations with a low pretest probability. We retrospectively studied outcomes of an unselected population (1819 patients) referred to a tertiary hospital laboratory for urinary metanephrine testing and investigated the usefulness of some simple derivative measures for detecting pheochromocytoma. We normalized values for urinary 24-h excretion of metanephrine, normetanephrine, and 3-methoxytyramine by dividing by an age- and sex-specific reference range. We then compared pheochromocytoma prediction by the use of products of these normalized measures with the gold standard of biopsy-confirmed tumor. The product of the excretion of normalized metanephrine (nMAD) and normalized normetanephrine (nNMT) (nMAD.nNMT) was a highly sensitive (100%) and specific (99.1%) measure, yielding a positive predictive value of 82%. ROC curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. The test for nMAD.nNMT gave higher sensitivity and specificity than the tests for either substance alone. The test for nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pretest probability.

  12. Cancer Screening Test Use - United States, 2015.

    PubMed

    White, Arica; Thompson, Trevor D; White, Mary C; Sabatino, Susan A; de Moor, Janet; Doria-Rose, Paul V; Geiger, Ann M; Richardson, Lisa C

    2017-03-03

    Healthy People 2020 (HP2020) includes objectives to increase screening for breast, cervical, and colorectal cancer (1) as recommended by the U.S. Preventive Services Task Force (USPSTF).* Progress toward meeting these objectives is monitored by measuring cancer screening test use against national targets using data from the National Health Interview Survey (NHIS) (1). Analysis of 2015 NHIS data indicated that screening test use remains substantially below HP2020 targets for selected cancer screening tests. Although colorectal cancer screening test use increased from 2000 to 2015, no improvements in test use were observed for breast and cervical cancer screening. Disparities exist in screening test use by race/ethnicity, socioeconomic status, and health care access indicators. Increased measures to implement evidence-based interventions and conduct targeted outreach are needed if the HP2020 targets for cancer screening are to be achieved and the disparities in screening test use are to be reduced.

  13. Safety in the Chemical Laboratory: Laboratory Air Quality: Part I. A Concentration Model.

    ERIC Educational Resources Information Center

    Butcher, Samuel S.; And Others

    1985-01-01

    Offers a simple model for estimating vapor concentrations in instructional laboratories. Three methods are described for measuring ventilation rates, and the results of measurements in six laboratories are presented. The model should provide a simple screening tool for evaluating worst-case personal exposures. (JN)

  14. The burden of HIV-associated neurocognitive disorder (HAND) in the Asia-Pacific region and recommendations for screening.

    PubMed

    Ian, Everall; Gwen, Chan Lai; Soo, Chow Ting; Melissa, Corr; Chun-Kai, Huang; Eosu, Kim; Hyo-Youl, Kim; Asad, Khan; Scott, Letendre; Chung-Ki, Li Patrick; Anekthananon, Thanomsak; Jordan, Treisman Glenn; Han-Ting, Wei; Wing-Wai, Wong

    2016-08-01

    HIV-associated neurocognitive disorder incurs a significant burden on HIV patients in Asia-Pacific countries; however, the incidence is difficult to estimate due to a lack of local epidemiological data. The impact of neurocognitive impairment in HIV patients is often underestimated due to a lack of education and awareness, and there are consequently gaps in the provision of screening and diagnosis to enable earlier intervention to limit neurocognitive impairment. This review seeks to redress the imbalance by promoting awareness and education among physicians concerning the neurovirulence of HIV and thereby increase screening efforts to improve diagnosis rates and clinical outcomes for underserved patients in this region. The Asia, Australia, and Middle East (AAME) HAND Advisory Board convened expert regional representatives to review current practice and recommend appropriate measures related to the implementation of standardised screening programmes and treatment recommendations to curb the developing HAND epidemic in the region. In particular, we recommend basic neuropsychological testing protocols that could be efficiently introduced into clinical practice for routine screening. We also propose simple guidelines for the management of HAND. We believe that HAND is a significant and under-reported diagnosis in HIV patients that warrants both greater recognition and further clinical investigation of the underlying pathophysiology and the impact of HIV disease progression, with HAND being associated with worse medication adherence and therefore possibly increased risk of ARV treatment failure. Widespread screening will lead to greater recognition of HAND and earlier intervention, which may lead to improved management strategies in the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A Risk Prediction Index for Advanced Colorectal Neoplasia at Screening Colonoscopy.

    PubMed

    Schroy, Paul C; Wong, John B; O'Brien, Michael J; Chen, Clara A; Griffith, John L

    2015-07-01

    Eliciting patient preferences within the context of shared decision making has been advocated for colorectal cancer screening. Risk stratification for advanced colorectal neoplasia (ACN) might facilitate more effective shared decision making when selecting an appropriate screening option. Our objective was to develop and validate a clinical index for estimating the probability of ACN at screening colonoscopy. We conducted a cross-sectional analysis of 3,543 asymptomatic, mostly average-risk patients 50-79 years of age undergoing screening colonoscopy at two urban safety net hospitals. Predictors of ACN were identified using multiple logistic regression. Model performance was internally validated using bootstrapping methods. The final index consisted of five independent predictors of risk (age, smoking, alcohol intake, height, and a combined sex/race/ethnicity variable). Smoking was the strongest predictor (net reclassification improvement (NRI), 8.4%) and height the weakest (NRI, 1.5%). Using a simplified weighted scoring system based on 0.5 increments of the adjusted odds ratio, the risk of ACN ranged from 3.2% (95% confidence interval (CI), 2.6-3.9) for the low-risk group (score ≤2) to 8.6% (95% CI, 7.4-9.7) for the intermediate/high-risk group (score 3-11). The model had moderate to good overall discrimination (C-statistic, 0.69; 95% CI, 0.66-0.72) and good calibration (P=0.73-0.93). A simple 5-item risk index based on readily available clinical data accurately stratifies average-risk patients into low- and intermediate/high-risk categories for ACN at screening colonoscopy. Uptake into clinical practice could facilitate more effective shared decision-making for CRC screening, particularly in situations where patient and provider test preferences differ.

  16. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.

    PubMed

    Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-02-01

    Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.

  17. A Simple Metallothionein-Based Biosensor for Enhanced Detection of Arsenic and Mercury

    PubMed Central

    Irvine, Gordon W.; Tan, Swee Ngin; Stillman, Martin J.

    2017-01-01

    Metallothioneins (MTs) are a family of cysteine-rich proteins whose biological roles include the regulation of essential metal ions and protection against the harmful effects of toxic metals. Due to its high affinity for many toxic, soft metals, recombinant human MT isoform 1a was incorporated into an electrochemical-based biosensor for the detection of As3+ and Hg2+. A simple design was chosen to maximize its potential in environmental monitoring and MT was physically adsorbed onto paper discs placed on screen-printed carbon electrodes (SPCEs). This system was tested with concentrations of arsenic and mercury typical of contaminated water sources ranging from 5 to 1000 ppb. The analytical performance of the MT-adsorbed paper discs on SPCEs demonstrated a greater than three-fold signal enhancement and a lower detection limit compared to blank SPCEs, 13 ppb for As3+ and 45 ppb for Hg2+. While not being as low as some of the recommended drinking water limits, the sensitivity of the simple MT-biosensor would be potentially useful in monitoring of areas of concern with a known contamination problem. This paper describes the ability of the metal binding protein metallothionein to enhance the effectiveness of a simple, low-cost electrochemical sensor. PMID:28335390

  18. Cushing's Syndrome: Screening and Diagnosis.

    PubMed

    Ceccato, Filippo; Boscaro, Marco

    2016-09-01

    Endogenous Cushing's syndrome (CS) is a rare disease, and usually characterized by hypertension, diabetes, obesity, osteoporosis, facial rounding, dorsocervical fat pad, thin skin, purple striae, hirsutism, and mood disorders. Efficient diagnostic and screening strategies lead to the diagnosis of a significantly higher number of cases of CS. As a screening test for CS, the Endocrine Society's Clinical Practice Guidelines recommend a single test with a high diagnostic accuracy, among the 1-mg dexamethasone suppression test (1-mg DST), late night salivary cortisol (LNSC), and 24 h urinary free cortisol (UFC). In normal subjects, administering a higher than physiological dose of glucocorticoids prompts the suppression of cortisol secretion. The 1-mg DST explores this normal feedback reaction from the hypothalamic-pituitary-adrenal axis (HPA). It is a simple dynamic test, usually performed in outpatients. A morning serum cortisol level <50 nmol/L suffices to exclude CS, unless there is a strong clinical suspicion to suggest otherwise. The HPA axis reaches a nadir just after a person has fallen asleep, but its circadian rhythm is impaired in CS patients, who feature higher cortisol values at night, which are easy to measure in saliva (the LNSC assay). Saliva collection is also suitable for outpatients since cortisol is stable at room temperature and the collection device can be mailed to the laboratory for analysis. UFC levels reflect the integrated tissue exposure to free cortisol over 24 h, and thus provide a particular picture of endogenous hypercortisolism. In most cases, high UFC levels coincide with severe hypercortisolism. UFC is used not only to diagnose CS, but also to monitor its response to medical treatment. All screening tests have procedural snares: some drugs can interfere with the DST; false-positive or false-negative LNSC results may be due to an inadequate soaking of the device or to cyclic CS; and in the case of UFC it is important to ensure that patients provide complete urine collections with appropriate total volumes. Measuring cortisol with antibody-based immunoassays can also generate false-positive results due to cross-reactivity between cortisol, cortisone and other metabolites. Structurally-based assays, such as liquid chromatography with tandem mass spectrometry, only measure cortisol and have only recently become available for use in routine clinical practice. This review summarizes the recent literature on the clinical and biochemical aspects of CS diagnostics with a view to helping physicians choose the best screening test for diagnosing endogenous hypercortisolism.

  19. Characterizing Information Processing With a Mobile Device: Measurement of Simple and Choice Reaction Time.

    PubMed

    Burke, Daniel; Linder, Susan; Hirsch, Joshua; Dey, Tanujit; Kana, Daniel; Ringenbach, Shannon; Schindler, David; Alberts, Jay

    2017-10-01

    Information processing is typically evaluated using simple reaction time (SRT) and choice reaction time (CRT) paradigms in which a specific response is initiated following a given stimulus. The measurement of reaction time (RT) has evolved from monitoring the timing of mechanical switches to computerized paradigms. The proliferation of mobile devices with touch screens makes them a natural next technological approach to assess information processing. The aims of this study were to determine the validity and reliability of using of a mobile device (Apple iPad or iTouch) to accurately measure RT. Sixty healthy young adults completed SRT and CRT tasks using a traditional test platform and mobile platforms on two occasions. The SRT was similar across test modality: 300, 287, and 280 milliseconds (ms) for the traditional, iPad, and iTouch, respectively. The CRT was similar within mobile devices, though slightly faster on the traditional: 359, 408, and 384 ms for traditional, iPad, and iTouch, respectively. Intraclass correlation coefficients ranged from 0.79 to 0.85 for SRT and from 0.75 to 0.83 for CRT. The similarity and reliability of SRT across platforms and consistency of SRT and CRT across test conditions indicate that mobile devices provide the next generation of assessment platforms for information processing.

  20. Brucella melitensis infection in sheep: present and future.

    PubMed

    Garin-Bastuji, B; Blasco, J M; Grayon, M; Verger, J M

    1998-01-01

    Sheep brucellosis, a zoonosis mainly due to B. melitensis (biovar 1, 2 or 3), remains widespread world-wide. Pathologically and epidemiologically, the disease is very similar to B. abortus infection in cattle. The live B. melitensis Rev 1 strain is currently considered as the best vaccine available for the control of sheep brucellosis, especially when used at the standard dose by the conjunctival route. Used exhaustively in whole-flock vaccination programmes, it induces a great decrease in the prevalence in both sheep and human populations. The expensive test-and-slaughter strategy should be restricted to the lowest infected areas. Whenever possible, Brucella spp. should be isolated by culture using adequate selective media from uterine discharges, aborted fetuses, udder secretions or selected tissues, such as lymph nodes, testes or epididymides. Species and biovar identification is routinely based on cultural criteria, on lysis by phages and on simple biochemical and serological tests. The recently developed polymerase chain reaction methods provide additional means of detection and identification. Despite the high degree of DNA homology within the genus Brucella, several methods, including PCR-RFLP and Southern blot, have been developed which allow, to a certain extent, the differentiation between Brucella species and some of their biovars. While several ELISA tests have been developed recently, the rose bengal plate agglutination and complement fixation tests, based on the detection of anti-S-LPS antibody, are still recommended for screening flocks and individuals. However, these tests sometimes lack specificity or sensitivity. For pooled samples, there are no useful tests such as the milk ring test in cattle. The brucellin allergic skin test can be used as a screening or complementary test in unvaccinated flocks, provided that a purified, lipopolysaccharide (LPS)-free and standardized antigen preparation is used.

  1. A Method for Identifying Small-Molecule Aggregators Using Photonic Crystal Biosensor Microplates

    PubMed Central

    Chan, Leo L.; Lidstone, Erich A.; Finch, Kristin E.; Heeres, James T.; Hergenrother, Paul J.; Cunningham, Brian T.

    2010-01-01

    Small molecules identified through high-throughput screens are an essential element in pharmaceutical discovery programs. It is now recognized that a substantial fraction of small molecules exhibit aggregating behavior leading to false positive results in many screening assays, typically due to nonspecific attachment to target proteins. Therefore, the ability to efficiently identify compounds within a screening library that aggregate can streamline the screening process by eliminating unsuitable molecules from further consideration. In this work, we show that photonic crystal (PC) optical biosensor microplate technology can be used to identify and quantify small-molecule aggregation. A group of aggregators and nonaggregators were tested using the PC technology, and measurements were compared with those gathered by three alternative methods: dynamic light scattering (DLS), an α-chymotrypsin colorimetric assay, and scanning electron microscopy (SEM). The PC biosensor measurements of aggregation were confirmed by visual observation using SEM, and were in general agreement with the α-chymotrypsin assay. DLS measurements, in contrast, demonstrated inconsistent readings for many compounds that are found to form aggregates in shapes, very different from the classical spherical particles assumed in DLS modeling. As a label-free detection method, the PC biosensor aggregation assay is simple to implement and provides a quantitative direct measurement of the mass density of material adsorbed to the transducer surface, whereas the microplate-based sensor format enables compatibility with high-throughput automated liquid-handling methods used in pharmaceutical screening. PMID:20930952

  2. Development of a New Decision Tree to Rapidly Screen Chemical Estrogenic Activities of Xenopus laevis.

    PubMed

    Wang, Ting; Li, Weiying; Zheng, Xiaofeng; Lin, Zhifen; Kong, Deyang

    2014-02-01

    During the last past decades, there is an increasing number of studies about estrogenic activities of the environmental pollutants on amphibians and many determination methods have been proposed. However, these determination methods are time-consuming and expensive, and a rapid and simple method to screen and test the chemicals for estrogenic activities to amphibians is therefore imperative. Herein is proposed a new decision tree formulated not only with physicochemical parameters but also a biological parameter that was successfully used to screen estrogenic activities of the chemicals on amphibians. The biological parameter, CDOCKER interaction energy (Ebinding ) between chemicals and the target proteins was calculated based on the method of molecular docking, and it was used to revise the decision tree formulated by Hong only with physicochemical parameters for screening estrogenic activity of chemicals in rat. According to the correlation between Ebinding of rat and Xenopus laevis, a new decision tree for estrogenic activities in Xenopus laevis is finally proposed. Then it was validated by using the randomly 8 chemicals which can be frequently exposed to Xenopus laevis, and the agreement between the results from the new decision tree and the ones from experiments is generally satisfactory. Consequently, the new decision tree can be used to screen the estrogenic activities of the chemicals, and combinational use of the Ebinding and classical physicochemical parameters can greatly improves Hong's decision tree. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Detection and Genotyping of Human Papillomavirus in Self-Obtained Cervicovaginal Samples by Using the FTA Cartridge: New Possibilities for Cervical Cancer Screening ▿

    PubMed Central

    Lenselink, Charlotte H.; de Bie, Roosmarie P.; van Hamont, Dennis; Bakkers, Judith M. J. E.; Quint, Wim G. V.; Massuger, Leon F. A. G.; Bekkers, Ruud L. M.; Melchers, Willem J. G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF10-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening. PMID:19553570

  4. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    PubMed

    Lenselink, Charlotte H; de Bie, Roosmarie P; van Hamont, Dennis; Bakkers, Judith M J E; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2009-08-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening.

  5. A simple risk score identifies individuals at high risk of developing Type 2 diabetes: a prospective cohort study.

    PubMed

    Rahman, Mushtaqur; Simmons, Rebecca K; Harding, Anne-Helen; Wareham, Nicholas J; Griffin, Simon J

    2008-06-01

    Randomized trials have demonstrated that Type 2 diabetes is preventable among high-risk individuals. To date, such individuals have been identified through population screening using the oral glucose tolerance test. To assess whether a risk score comprising only routinely collected non-biochemical parameters was effective in identifying those at risk of developing Type 2 diabetes. Population-based prospective cohort (European Prospective Investigation of Cancer-Norfolk). Participants aged 40-79 recruited from UK general practices attended a health check between 1993 and 1998 (n = 25 639) and were followed for a mean of 5 years for diabetes incidence. The Cambridge Diabetes Risk Score was computed for 24 495 individuals with baseline data on age, sex, prescription of steroids and anti-hypertensive medication, family history of diabetes, body mass index and smoking status. We examined the incidence of diabetes across quintiles of the risk score and plotted a receiver operating characteristic (ROC) curve to assess discrimination. There were 323 new cases of diabetes, a cumulative incidence of 2.76/1000 person-years. Those in the top quintile of risk were 22 times more likely to develop diabetes than those in the bottom quintile (odds ratio 22.3; 95% CI: 11.0-45.4). In all, 54% of all clinically incident cases occurred in individuals in the top quintile of risk (risk score > 0.37). The area under the ROC was 74.5%. The risk score is a simple, effective tool for the identification of those at risk of developing Type 2 diabetes. Such methods may be more feasible than mass population screening with biochemical tests in defining target populations for prevention programmes.

  6. Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach

    NASA Astrophysics Data System (ADS)

    Sumriddetchkajorn, Sarun; Chaitavon, Kosom

    2009-07-01

    This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1 ms processing time in highlighting all human face areas. With a thermal imaging camera having an FOV lens of 24° × 18° and 320 × 240 active pixels, the maximum facial skin temperatures from three people's faces located at 1.3 m from the camera can also be simultaneously monitored and displayed in a measured rate of 31 fps, limited by the looping process in determining coordinates of all faces. For our 3-day test under the ambient temperature of 24-30 °C, 57-72% relative humidity, and weak wind from the outside hospital building, hyperthermic patients can be identified with 100% sensitivity and 36.4% specificity when the temperature threshold level and the offset temperature value are appropriately chosen. Appropriately locating our system away from the building doors, air conditioners and electric fans in order to eliminate wind blow coming toward the camera lens can significantly help improve our system specificity.

  7. Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter.

    PubMed

    Balion, Cynthia; Grey, Vijaylaxmi; Ismaila, Afisi; Blatz, Susan; Seidlitz, Wendy

    2006-11-03

    Point of care (POC) glucose meters are routinely used as a screening tool for hypoglycemia in a neonatal setting. Glucose meters however, lack the same accuracy as laboratory instruments for glucose measurement. In this study we investigated potential reasons for this inaccuracy and established a cut off value for confirmatory testing. In this prospective study, all patients in the neonatal intensive care unit who had a plasma glucose test ordered were eligible to participate. Demographic information, sample collection information (nine variables) and a recent hematocrit value were recorded for each sample. Glucose measurements were taken at the bedside on the glucose meter (RN PCx) as well as in the laboratory on both the glucose meter (LAB PCx) and the laboratory analyzer (PG). Data were analyzed by simple and mixed-effects regression analysis and by analysis of a receiver operator characteristics (ROC) curve. There were 475 samples analyzed from 132 patients. RN PCx values were higher than PG values (mean = 4.9%), while LAB PCx results were lower (mean = -5.2%) than PG values. Only 31% of the difference between RN PCx--PG and 46% of the difference for LAB PCx--PG could be accounted for by the variables tested. The largest proportion of variance between PCx and PG measurements was explained by hematocrit (about 30%) with a greater effect seen at glucose concentrations < or =4.0 mmol/L (< or =72 mg/dL)(48% and 40% for RN PCx and LAB PCx, respectively). The ROC analysis showed that for detection of all cases of hypoglycemia (PG < 2.6 mmol/L)(PG < 47 mg/dL) the PCx screening cut off value would need to be set at 3.8 mmol/L (68 mg/dL) requiring 20% of all samples to have confirmatory analysis by the laboratory method. The large difference between glucose results obtained by PCx glucose meter compared to the laboratory analyzer can be explained in part by hematocrit and low glucose concentration. These results emphasize that the glucose meter is useful only as a screening device for neonatal hypoglycemia and that a screening cut off value must be established.

  8. Footprint (A Screening Model for Estimating the Area of a Plume Produced from Gasoline Containing Ethanol

    EPA Science Inventory

    FOOTPRINT is a simple and user-friendly screening model to estimate the length and surface area of BTEX plumes in ground water produced from a spill of gasoline that contains ethanol. Ethanol has a potential negative impact on the natural biodegradation of BTEX compounds in groun...

  9. A small-bolt method for screening tree protectants against bark beetles (coleoptera: curculionidae)

    Treesearch

    B.L. Strom; L.M. Roton

    2009-01-01

    A simple, small-bolt method was developed and refi ned for evaluating and screening treatments being considered as prophylactics against bark beetles (Coleoptera: Curculionidae: Scolytinae). Using this method, 4 insecticide products (3 active ingredients) were evaluated against the southern pine beetle, Dendroctonus frontalis Zimmermann, intermittently during a period...

  10. FOOTPRINT: A New Tool to Predict the Potential Impact of Biofuels on BTEX Plumes

    EPA Science Inventory

    Ahsanuzzaman et al. (2008) used the Deeb et al. (2002) conceptual model to construct a simple screening model to estimate the area of a plume of benzene produced from a release of gasoline containing ethanol. The screening model estimates the plume area, or footprint of the plum...

  11. Should We Be Afraid of Simple Messages? The Effects of Text Difficulty and Illustrations in People With Low or High Health Literacy.

    PubMed

    Meppelink, Corine S; Smit, Edith G; Buurman, Bianca M; van Weert, Julia C M

    2015-01-01

    It is often recommended that health information should be simplified for people with low health literacy. However, little is known about whether messages adapted to low health literacy audiences are also effective for people with high health literacy, or whether simple messages are counterproductive in this group. Using a two (illustrated vs. text-only) by two (nondifficult vs. difficult text) between-subjects design, we test whether older adults with low (n = 279) versus high health literacy (n = 280) respond differently to colorectal cancer screening messages. Results showed that both health literacy groups recalled information best when the text was nondifficult. Reduced text difficulty did not lead to negative attitudes or less intention to have screening among people with high health literacy. Benefits of illustrations, in terms of improved recall and attitudes, were only found in people with low health literacy who were exposed to difficult texts. This was not found for people with high health literacy. In terms of informed decisions, nondifficult and illustrated messages resulted in the best informed decisions in the low health literacy group, whereas the high health literacy group benefited from nondifficult text in general, regardless of illustrations. Our findings imply that materials adapted to lower health literacy groups can also be used for a more general audience, as they do not deter people with high health literacy.

  12. Toluidine blue: rapid and simple malaria parasite screening and species identification.

    PubMed

    Awale, Rupali; Maji, Ratnaprabha; Patil, Parag; Lingiah, Raghavendra; Mukhopadhyay, Ashok Kumar; Sharma, Subhadra

    2017-01-01

    Malaria, a febrile illness mostly confined to the tropical countries is transmitted by bite of infected female Anopheles mosquito. In 2015 alone, 88% of the malaria burden and 90% deaths due to malaria were confined to the African and Asian countries. Although number of tests are available for rapid diagnosis and screening for malaria, peripheral blood smear examination remains the gold standard. Leishman stain is recommended by WHO however herein we evaluate one of the alternative methods of staining which is simple and rapid. Fifty patients attending the various outpatient departments of the tertiary care hospital with fever and suspected to have malaria were selected. Two thin-air dried smears prepared from the peripheral venous blood from these subjects were stained by Leishman and Toluidine blue method. The findings of the slides by two independent qualified professionals were noted and the results were analyzed. A total of 14% (7/50) cases were diagnosed to have malaria. All the malaria cases which were positive in Leishman stain were also detected in Toluidine blue stain. Malarial parasites were clearly visible against the homogenously light green background in Toluidine blue. The detection of malarial parasite by Toluidine blue was quick, easy and confirmative. Toluidine blue stained peripheral blood smear allows for easy identification and speciation of malarial parasite at low magnification and in shorter period of time.

  13. Simplified Pan-species Real-time PCR-based Detection of Plasmodium Spp. in Blood Smear.

    PubMed

    Hassanpour, Gholamreza; Mirhendi, Hossein; Mohebali, Mehdi; Raeisi, Ahmad; Zeraati, Hojjat; Keshavarz, Hossein

    2016-01-01

    We aimed to quicken and simplify the detection of Plasmodium in blood samples by developing and testing a pan- Plasmodium real-time PCR for accurate screening of individuals suspected of malaria. A single primer/probe set for pan-species Plasmodium -specific real time PCR targeting a conserved region of the small subunit 18S ribosomal DNA was designed and evaluated for rapid diagnosis and screening of malaria infections using dried blood smears. FTA cards were used for rapid and simple DNA extraction. The primers and probes showed a positive response with the DNA extracted from bloods infected with P. falciparum and P. vivax but not with DNA extracted from various smears from uninfected blood samples. Seven positive cases positive by both microscopy and nested PCR were found among 280 blood samples taken from in South and Southeast Iran. Five samples were identified as positive for P. vivax and two as positive for P. falciparum . All positive samples were positive by real-time PCR. Furthermore, all 38-blood samples positive by microscopy were positive by real-time PCR. No microscopy-negative samples were positive by real-time PCR. By using a simple FTA card for DNA extraction and by application of the real-time PCR developed in this study, sensitivity similar to nested-PCR and microscopy was achieved. This format simplifies the detection of Plasmodium in large numbers of samples.

  14. MAP: an iterative experimental design methodology for the optimization of catalytic search space structure modeling.

    PubMed

    Baumes, Laurent A

    2006-01-01

    One of the main problems in high-throughput research for materials is still the design of experiments. At early stages of discovery programs, purely exploratory methodologies coupled with fast screening tools should be employed. This should lead to opportunities to find unexpected catalytic results and identify the "groups" of catalyst outputs, providing well-defined boundaries for future optimizations. However, very few new papers deal with strategies that guide exploratory studies. Mostly, traditional designs, homogeneous covering, or simple random samplings are exploited. Typical catalytic output distributions exhibit unbalanced datasets for which an efficient learning is hardly carried out, and interesting but rare classes are usually unrecognized. Here is suggested a new iterative algorithm for the characterization of the search space structure, working independently of learning processes. It enhances recognition rates by transferring catalysts to be screened from "performance-stable" space zones to "unsteady" ones which necessitate more experiments to be well-modeled. The evaluation of new algorithm attempts through benchmarks is compulsory due to the lack of past proofs about their efficiency. The method is detailed and thoroughly tested with mathematical functions exhibiting different levels of complexity. The strategy is not only empirically evaluated, the effect or efficiency of sampling on future Machine Learning performances is also quantified. The minimum sample size required by the algorithm for being statistically discriminated from simple random sampling is investigated.

  15. How to report and interpret screening test properties: guidelines for driving researchers.

    PubMed

    Weaver, Bruce; Walter, Stephen D; Bédard, Michel

    2014-01-01

    One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.

  16. A Simple Symptom Score for Acute HIV Infection in a San Diego Community Based Screening Program.

    PubMed

    Lin, Timothy C; Gianella, Sara; Tenenbaum, Tara; Little, Susan J; Hoenigl, Martin

    2017-12-25

    Treatment of acute HIV infection (AHI) decreases transmission and preserves immune function, but AHI diagnosis remains resource-intensive. Risk-based scores predictive for AHI have been described for high-risk groups, however symptom-based scores could be more generalizable across populations. Adults who tested either positive for AHI (antibody-negative, HIV nucleic acid test [NAT]-positive) or HIV NAT-negative with the community-based Early Test HIV screening program in San Diego were retrospectively randomized 2:1 into a derivation and validation set. In the former, symptoms significant for AHI in a multivariate logistic regression model were assigned a score value (the odds ratio rounded to the nearest integer). The score was assessed in the validation set using receiver operating characteristics and areas under the curve (AUC). An optimal cut-off score was found using Youden's index. Of 998 participants (including 737 men who have sex with men (MSM), 149 non-MSM men, 109 ciswomen and 3 trans women), 113 had AHI (including 109 MSM). Compared to HIV-negative cases, AHI cases reported more symptoms (median 4 vs 0, p<0.01). Fever, myalgia and weight loss were significantly associated with AHI in the multivariate model and corresponded to 11, 8 and 4 score points, respectively. The summed score yielded AUC of 0.85 (95%CI 0.77-0.93). A score of ≥11 was 72% sensitive, 96% specific with diagnostic odds ratio of 70.27 (95%CI 28.14-175.93). A 3-symptom score accurately predicted AHI in a community based screening program and may inform allocation of resources in settings that do not routinely screen for AHI. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  17. Mycobacterium avium restriction fragment length polymorphism-IS IS1245 and the simple double repetitive element polymerase chain reaction typing method to screen genetic diversity in Brazilian strains.

    PubMed

    Sequeira, Patrícia Carvalho de; Fonseca, Leila de Souza; Silva, Marlei Gomes da; Saad, Maria Helena Féres

    2005-11-01

    Simple double repetitive element polymerase chain reaction (MaDRE-PCR) and Pvu II-IS1245 restriction fragment length polymorphism (RFLP) typing methods were used to type 41 Mycobacterium avium isolates obtained from 14 AIDS inpatients and 10 environment and animals specimens identified among 53 mycobacteria isolated from 237 food, chicken, and pig. All environmental and animals strains showed orphan patterns by both methods. By MaDRE-PCR four patients, with multiple isolates, showed different patterns, suggesting polyclonal infection that was confirmed by RFLP in two of them. This first evaluation of MaDRE-PCR on Brazilian M. avium strains demonstrated that the method seems to be useful as simple and less expensive typing method for screening genetic diversity in M. avium strains on selected epidemiological studies, although with limitation on analysis identical patterns except for one band.

  18. A simple heterogeneous one-step assay for screening estrogenic compounds.

    PubMed

    Huovinen, Tuomas; Rytkönen, Kalle; Lamminmäki, Urpo; Pellinen, Teijo

    2013-01-01

    Estrogen receptor (ER) modulators are a serious health issue but estrogenic compounds, especially antagonists of ER function, are widely screened for in search of novel therapeutics against hormonal diseases such as the breast cancer. Here we report a novel and a simple bioassay for estrogenic and anti-estrogenic compounds based on ligand-dependent recruitment of ER co-activator steroid receptor co-activator 1 (SRC-1) to purified Renilla luciferase-tagged ERα. In this assay, in vivo-biotinylated (E. coli) SRC-1, purified Renilla luciferase-ERα, and the analyte sample are mixed and incubated for 2 h in a streptavidin-coated microtiter wells, and after one washing step, luminescence is measured with a simple instrument. The assay does not require chemical labeling of the components and shows good sensitivity (25 pM E(2)) and wide dynamic range of more than four orders of magnitude.

  19. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    PubMed

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  20. Pilot testing of dipsticks as point-of-care assays for rapid diagnosis of poor-quality artemisinin drugs in endemic settings.

    PubMed

    Guo, Suqin; He, Lishan; Tisch, Daniel J; Kazura, James; Mharakurwa, Sungano; Mahanta, Jagadish; Herrera, Sócrates; Wang, Baomin; Cui, Liwang

    2016-01-01

    Good-quality artemisinin drugs are essential for malaria treatment, but increasing prevalence of poor-quality artemisinin drugs in many endemic countries hinders effective management of malaria cases. To develop a point-of-care assay for rapid identification of counterfeit and substandard artemisinin drugs for resource-limited areas, we used specific monoclonal antibodies against artesunate and artemether, and developed prototypes of lateral flow dipstick assays. In this pilot test, we evaluated the feasibility of these dipsticks under different endemic settings and their performance in the hands of untrained personnel. The results showed that the dipstick tests can be successfully performed by different investigators with the included instruction sheet. None of the artemether and artesunate drugs collected from public pharmacies in different endemic countries failed the test. It is possible that the simple dipstick assays, with future optimization of test conditions and sensitivity, can be used as a qualitative and semi-quantitative assay for rapid screening of counterfeit artemisinin drugs in endemic settings.

  1. Web-Based Versus Conventional Training for Medical Students on Infant Gross Motor Screening.

    PubMed

    Pusponegoro, Hardiono D; Soebadi, Amanda; Surya, Raymond

    2015-12-01

    Early detection of developmental abnormalities is important for early intervention. A simple screening method is needed for use by general practitioners, as is an effective and efficient training method. This study aims to evaluate the effectiveness, acceptability, and usability of Web-based training for medical students on a simple gross motor screening method in infants. Fifth-year medical students at University of Indonesia in Jakarta were randomized into two groups. A Web-based training group received online video modules, discussions, and assessments (at www.schoology.com ). A conventional training group received a 1-day live training using the same module. Both groups completed identical pre- and posttests and the User Satisfaction Questionnaire (USQ). The Web-based group also completed the System Usability Scale (SUS). The module was based on a gross motor screening method used in the World Health Organization Multicentre Growth Reference Study. There were 39 and 32 subjects in the Web-based and conventional groups, respectively. Mean pretest versus posttest scores (correct answers out of 20) were 9.05 versus 16.95 (p=0.0001) in the Web-based group and 9.31 versus 16.88 (p=0.0001) in the conventional group. Mean difference between pre- and posttest scores did not differ significantly between the Web-based and conventional groups (mean [standard deviation], 7.56 [3.252] versus 7.90 [5.170]; p=0.741]. Both training methods were acceptable based on USQ scores. Based on SUS scores, the Web-based training had good usability. Web-based training is an effective, efficient, and acceptable training method for medical students on simple infant gross motor screening and is as effective as conventional training.

  2. Cost-effectiveness of preoperative nasal mupirocin treatment in preventing surgical site infection in patients undergoing total hip and knee arthroplasty: a cost-effectiveness analysis.

    PubMed

    Courville, Xan F; Tomek, Ivan M; Kirkland, Kathryn B; Birhle, Marian; Kantor, Stephen R; Finlayson, Samuel R G

    2012-02-01

    To perform a cost-effectiveness analysis to evaluate preoperative use of mupirocin in patients with total joint arthroplasty (TJA). Simple decision tree model. Outpatient TJA clinical setting. Hypothetical cohort of patients with TJA. A simple decision tree model compared 3 strategies in a hypothetical cohort of patients with TJA: (1) obtaining preoperative screening cultures for all patients, followed by administration of mupirocin to patients with cultures positive for Staphylococcus aureus; (2) providing empirical preoperative treatment with mupirocin for all patients without screening; and (3) providing no preoperative treatment or screening. We assessed the costs and benefits over a 1-year period. Data inputs were obtained from a literature review and from our institution's internal data. Utilities were measured in quality-adjusted life-years, and costs were measured in 2005 US dollars. Incremental cost-effectiveness ratio. The treat-all and screen-and-treat strategies both had lower costs and greater benefits, compared with the no-treatment strategy. Sensitivity analysis revealed that this result is stable even if the cost of mupirocin was over $100 and the cost of SSI ranged between $26,000 and $250,000. Treating all patients remains the best strategy when the prevalence of S. aureus carriers and surgical site infection is varied across plausible values as well as when the prevalence of mupirocin-resistant strains is high. Empirical treatment with mupirocin ointment or use of a screen-and-treat strategy before TJA is performed is a simple, safe, and cost-effective intervention that can reduce the risk of SSI. S. aureus decolonization with nasal mupirocin for patients undergoing TJA should be considered. Level II, economic and decision analysis.

  3. Simple and rapid screening procedure for 143 new psychoactive substances by liquid chromatography-tandem mass spectrometry.

    PubMed

    Adamowicz, Piotr; Tokarczyk, Bogdan

    2016-07-01

    In recent years, many new psychoactive substances (NPS) from several drug classes have appeared on the drug market. These substances, also known as 'legal highs', belong to different chemical classes. Despite the increasing number of NPS, there are few comprehensive screening methods for their detection in biological specimens. In this context, the purpose of this study was to develop a fast and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening procedure for NPS in blood. The elaborated method allows the simultaneous screening of 143 compounds from different groups (number of compounds): cathinones (36), phenethylamines (26), tryptamines (18), piperazines (9), piperidines (2), synthetic cannabinoids (34), arylalkylamines (7), arylcyclohexylamines (3), aminoindanes (2), and other drugs (6). Blood samples (0.2 mL) were precipitated with acetonitrile (0.6 mL). The separation was achieved with gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 14 min. Detection of all compounds was based on multiple reaction monitoring (MRM) transitions. The total number of transitions monitored in dynamic mode was 432. The whole procedure was rapid and simple. The limits of detection (LODs) estimated for 104 compounds were in the range 0.01-3.09 ng/mL. The extraction recoveries determined for 32 compounds were from 1.8 to 133%. The procedure was successfully applied to the analysis of forensic blood samples in routine casework. The developed method should have wide applicability for rapid screening of new drugs of abuse in forensic or clinical samples. The procedure can be easily expanded for more substances. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Rapid Screening and Characterization of Acetylcholinesterase Inhibitors from Yinhuang Oral Liquid Using Ultrafiltration-liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry

    PubMed Central

    Zhang, Haomin; Guo, Yinan; Meng, Lingwen; Sun, Hui; Yang, Yinping; Gao, Ying; Sun, Jiaming

    2018-01-01

    Background: At present, approximately 17–25 million people in the world suffer from Alzheimer's disease (AD). The most efficacious and acceptable therapeutic drug clinically are the acetylcholinesterase inhibitors (AChEIs). Yinhuang oral liquid is a Chinese medicine preparation which contains AChEIs according to the literatures. However, no strategy has been presented for rapid screening and identification of AChEIs from Yinhuang oral liquid. Objective: To develop a method for rapid screening and identification of AChEIs from Yinhuang oral liquid using ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry (UF-LC-ESI-MS/MS). Materials and Methods: In this study, UF incubation conditions such as enzyme concentration, incubation time, and incubation temperature were optimized so as to get better screening results. The AChEIs from Yinhuang oral liquid were identified by high-performance liquid chromatography-ESI-MS and the improved Ellman method was used for the AChE inhibitory activity test in vitro. Results: The results showed that Yinhuang oral liquid can inhibit the activity of AChE. We screened and identified seven compounds with potential AChE inhibitory activity from Yinhuang oral liquid, which provided experimental basis for the treatment and prevention of AD. Conclusion: The current technique was used to directly screen the active ingredients with acetylcholinesterase inhibition from complex traditional Chinese medicine, which was simple, rapid, accurate, and suitable for high-throughput screening of AChEI from complex systems. SUMMARY A UF-LC-ESI-MS/MS method for rapid screening and identification of AChEIs from Yinhuang oral liquid was developedSeven compounds were screened and identified with potential AChE inhibitory activity from Yinhuang oral liquidIt provided experimental basis of Yinhuang oral liquid for the treating and preventing AD. Abbreviations used: (AD): Alzheimer's disease; (UF-LC-ESI-MS/MS): ultrafiltration–liquid chromatography–electrospray ionization tandem mass spectrometry; (AChEIs): acetylcholinesterase inhibitors. PMID:29720840

  5. Engineering cancer microenvironments for in vitro 3-D tumor models

    PubMed Central

    Asghar, Waseem; El Assal, Rami; Shafiee, Hadi; Pitteri, Sharon; Paulmurugan, Ramasamy; Demirci, Utkan

    2017-01-01

    The natural microenvironment of tumors is composed of extracellular matrix (ECM), blood vasculature, and supporting stromal cells. The physical characteristics of ECM as well as the cellular components play a vital role in controlling cancer cell proliferation, apoptosis, metabolism, and differentiation. To mimic the tumor microenvironment outside the human body for drug testing, two-dimensional (2-D) and murine tumor models are routinely used. Although these conventional approaches are employed in preclinical studies, they still present challenges. For example, murine tumor models are expensive and difficult to adopt for routine drug screening. On the other hand, 2-D in vitro models are simple to perform, but they do not recapitulate natural tumor microenvironment, because they do not capture important three-dimensional (3-D) cell–cell, cell–matrix signaling pathways, and multi-cellular heterogeneous components of the tumor microenvironment such as stromal and immune cells. The three-dimensional (3-D) in vitro tumor models aim to closely mimic cancer microenvironments and have emerged as an alternative to routinely used methods for drug screening. Herein, we review recent advances in 3-D tumor model generation and highlight directions for future applications in drug testing. PMID:28458612

  6. An electrochemical immunoassay for the screening of celiac disease in saliva samples.

    PubMed

    Adornetto, Gianluca; Fabiani, Laura; Volpe, Giulia; De Stefano, Alessia; Martini, Sonia; Nenna, Raffaella; Lucantoni, Federica; Bonamico, Margherita; Tiberti, Claudio; Moscone, Danila

    2015-09-01

    A highly sensitive electrochemical immunoassay for the initial diagnosis of celiac disease (CD) in saliva samples that overcomes the problems related to its high viscosity and to the low concentration of anti-transglutaminase antigen (tTG) IgA in this medium has been developed for the first time. The system uses magnetic beads (MBs) covered with tTG, which reacts with the anti-tTG IgA antibodies present in positive saliva samples. An anti-human IgA, conjugated with alkaline phosphate (AP) enzyme, was used as the label and a strip of eight magnetized screen-printed electrodes as the electrochemical transducer. In particular, two different immunoassay approaches were optimized and blindly compared to analyze a large number of saliva samples, whose anti-tTG IgA levels were independently determined by the radioimmunoassay (RIA) method. The obtained results, expressed as Ab index, were used to perform a diagnostic test evaluation through the construction of receiver operating characteristic (ROC) curves. The approach, involving a pre-incubation between the anti-human IgA-AP and saliva samples prior to the addition of MBs-tTG, showed a cutoff of 0.022 with 95% clinical sensitivity and 96% clinical specificity. The area under the ROC curve is equal to 1, a result that classifies our test as "perfect." This study demonstrates that it is possible to perform the screening of CD with a rapid, simple, inexpensive, and sensitive method able to detect anti-tTG antibodies in saliva samples, which are easily obtained by non-invasive techniques. This aspect is of fundamental importance to screen a large number of subjects, especially in the pediatric age.

  7. To Screen or Not to Screen? The Benefits and Harms of Screening Tests

    MedlinePlus

    ... issue To Screen or Not to Screen? The Benefits and Harms of Screening Tests En español Send ... test, talk with your doctor about the possible benefits and harms to help you decide what’s best ...

  8. Comparative study of different alcohol sensors based on Screen-Printed Carbon Electrodes.

    PubMed

    Costa Rama, Estefanía; Biscay, Julien; González García, María Begoña; Julio Reviejo, A; Pingarrón Carrazón, José Manuel; Costa García, Agustín

    2012-05-30

    Different very simple single-use alcohol enzyme sensors were developed using alcohol oxidase (AOX) from three different yeast, Hansenula sp., Pichia pastoris and Candida boidinii, and employing three different commercial mediator-based Screen-Printed Carbon Electrodes as transducers. The mediators tested, Prussian Blue, Ferrocyanide and Co-phthalocyanine were included into the ink of the working electrode. The procedure to obtain these sensors consists of the immobilization of the enzyme on the electrode surface by adsorption. For the immobilization, an AOX solution is deposited on the working electrode and left until dried (1h) at room temperature. The best results were obtained with the biosensor using Screen-Printed Co-phthalocyanine/Carbon Electrode and AOX from Hansenula sp. The reduced cobalt-phthalocyanine form is amperometrically detected at +0.4V (vs. Ag pseudo reference electrode). This sensor shows good sensitivity (1211 nA mM(-1)), high precision (2.1% RSD value for the slope value of the calibration plot) and wide linear response (0.05-1.00 mM) for ethanol determination. The sensor provides also accurate results for ethanol quantification in alcoholic drinks. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Validation of a Screening Questionnaire for Chronic Leg Ulcers.

    PubMed

    Zarchi, Kian; Theut Riis, Peter; Graversgaard, Christine; Miller, Iben M; Heidenheim, Michael; Jemec, Gregor B E

    2016-12-01

    The use of a validated screening questionnaire to identify individuals with chronic leg ulcers allows large-scale population-based studies to be conducted that measure and monitor the prevalence of the disease. The aim of this study was to design and validate such a screening questionnaire to identify patients with chronic leg ulcers. A simple 3-item questionnaire was developed at the Department of Dermatology, University Hospital of Zealand, Denmark. In total, 90 patients attending the department's outpatient clinic for dermatological diseases and chronic wounds were included in this study. All included participants completed the questionnaire and were subsequently examined by dermatologists. We found that the constructed 3-item questionnaire in this study had a sensitivity and specificity of 95% and 93% and a positive predictive value and negative predictive value of 78% and 95%, respectively. Moreover, we found that the use of the 3-item questionnaire, as compared with a single question, in which the participants were asked whether they currently have a leg ulcer, resulted in significantly higher positive predictive value (+11.6%, P = .035) and specificity (+5.6%, P = .046) of the diagnostic test. Future studies are merited to investigate the diagnostic accuracy of the questionnaire in other populations and settings.

  10. Testing a single regression coefficient in high dimensional linear models

    PubMed Central

    Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling

    2017-01-01

    In linear regression models with high dimensional data, the classical z-test (or t-test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z-test to assess the significance of each covariate. Based on the p-value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively. PMID:28663668

  11. Testing a single regression coefficient in high dimensional linear models.

    PubMed

    Lan, Wei; Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling

    2016-11-01

    In linear regression models with high dimensional data, the classical z -test (or t -test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z -test to assess the significance of each covariate. Based on the p -value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively.

  12. Internally coated air-cooled gas turbine blading

    NASA Technical Reports Server (NTRS)

    Hsu, L.; Stevens, W. G.; Stetson, A. R.

    1979-01-01

    Ten candidate modified nickel-aluminide coatings were developed using the slip pack process. These coatings contain additives such as silicon, chromium and columbium in a nickel-aluminum coating matrix with directionally solidified MAR-M200 + Hf as the substrate alloy. Following a series of screening tests which included strain tolerance, dynamic oxidation and hot corrosion testing, the Ni-19A1-1Cb (nominal composition) coating was selected for application to the internal passages of four first-stage turbine blades. Process development results indicate that a dry pack process is suitable for internal coating application resulting in 18 percent or less reduction in air flow. Coating uniformity, based on coated air-cooled blades, was within + or - 20 percent. Test results show that the presence of additives (silicon, chromium or columbium) appeared to improve significantly the ductility of the NiA1 matrix. However, the environmental resistance of these modified nickel-aluminides were generally inferior to the simple aluminides.

  13. Operational trial of ParaSight-F (dipstick) in the diagnosis of falciparum malaria at the primary health care level.

    PubMed

    Banchongaksorn, T; Prajakwong, S; Rooney, W; Vickers, P

    1997-06-01

    The rapid manual ParaSight-F test of Plasmodium falciparum malaria, an antigen capture test for detecting trophozoite-derived histidine rich protein-2 (PF HRP-2), is simple to perform and provides a definite diagnosis within 10 minutes. During an operational trial at health centers and mobile malaria units where microscopical diagnosis is not available and using defined symptom screening criteria, 3,361 subjects were tested yielding 618 positives (18.4%) for PF-HRP-2 by ParaSight-F. Microscopic examination of the same subjects by thick blood film examined 7 days later at a malaria clinic showed 578 falciparum, and 349 vivax and mixed infection (F+V) 41. The technology proved highly effective in detecting falciparum malaria at the peripheral levels where access to malaria laboratory services are difficult, thus allowing immediate administration of a complete course of treatment in the absence of a microscopic examination.

  14. Development of a screening system for cystic fibrosis.

    PubMed

    Coury, A J; Fogt, E J; Norenberg, M S; Untereker, D F

    1983-09-01

    We have developed a simple method for detecting high concentrations of chloride in sweat from ambulatory subjects, a measurement useful in the detection of cystic fibrosis. The method is based on the standard approach of stimulating sweat generation through iontophoresis of pilocarpine nitrate into the skin, followed by collection and analysis of the sweat for chloride concentration. The sweat-stimulating reagents are contained in polymeric gel pads, which are used in conjunction with a small battery-powered stimulator. The chloride analysis is subsequently done on the stimulated site by use of a thin test patch that picks up a fixed amount of sweat and changes color if the chloride concentration is higher than a predetermined value. The successful completion of a test is indicated by a fill tab, which changes color when the appropriate amount of sweat has been picked up by the chloride test patch.

  15. Multiplex PCR for Rapid Detection of Genes Encoding Class A Carbapenemases

    PubMed Central

    Hong, Sang Sook; Kim, Kyeongmi; Huh, Ji Young; Jung, Bochan; Kang, Myung Seo

    2012-01-01

    In recent years, there have been increasing reports of KPC-producing Klebsiella pneumoniae in Korea. The modified Hodge test can be used as a phenotypic screening test for class A carbapenamase (CAC)-producing clinical isolates; however, it does not distinguish between carbapenemase types. The confirmation of type of CAC is important to ensure optimal therapy and to prevent transmission. This study applied a novel multiplex PCR assay to detect and differentiate CAC genes in a single reaction. Four primer pairs were designed to amplify fragments encoding 4 CAC families (SME, IMI/NMC-A, KPC, and GES). The multiplex PCR detected all genes tested for 4 CAC families that could be differentiated by fragment size according to gene type. This multiplex PCR offers a simple and useful approach for detecting and distinguishing CAC genes in carbapenem-resistant strains that are metallo-β-lactamase nonproducers. PMID:22950072

  16. Multiplex PCR for rapid detection of genes encoding class A carbapenemases.

    PubMed

    Hong, Sang Sook; Kim, Kyeongmi; Huh, Ji Young; Jung, Bochan; Kang, Myung Seo; Hong, Seong Geun

    2012-09-01

    In recent years, there have been increasing reports of KPC-producing Klebsiella pneumoniae in Korea. The modified Hodge test can be used as a phenotypic screening test for class A carbapenamase (CAC)-producing clinical isolates; however, it does not distinguish between carbapenemase types. The confirmation of type of CAC is important to ensure optimal therapy and to prevent transmission. This study applied a novel multiplex PCR assay to detect and differentiate CAC genes in a single reaction. Four primer pairs were designed to amplify fragments encoding 4 CAC families (SME, IMI/NMC-A, KPC, and GES). The multiplex PCR detected all genes tested for 4 CAC families that could be differentiated by fragment size according to gene type. This multiplex PCR offers a simple and useful approach for detecting and distinguishing CAC genes in carbapenem-resistant strains that are metallo-β-lactamase nonproducers.

  17. Assessment of a New Lower-Cost Real-Time PCR Assay for Detection of High-Risk Human Papillomavirus: Useful for Cervical Screening in Limited-Resource Settings?

    PubMed Central

    Schiffman, Mark; Wentzensen, Nicolas H.; Gage, Julia C.; Castle, Philip E.; Raine-Bennett, Tina R.; Fetterman, Barbara; Lorey, Thomas; Poitras, Nancy E.; Befano, Brian; Xie, Yi; Miachon, Lais S.; Dean, Michael

    2017-01-01

    ABSTRACT Inexpensive and easy-to-perform human papillomavirus (HPV) tests are needed for primary cervical cancer screening in lower-resource regions. In a convenience sample of 516 residual exfoliative cervical specimens from the Kaiser Permanente Northern California and U.S. National Cancer Institute Persistence and Progression Study, we assessed the agreement and clinical performance of a simple, inexpensive real-time PCR assay for the detection of 13 carcinogenic HPV types (the H13 assay; Hybribio, Hong Kong) that is marketed in limited-resource settings compared to previous testing by the Hybrid Capture 2 assay (HC2; Qiagen, Germantown, MD) and the Onclarity assay (BD Diagnostics, Sparks, MD). The test set was chosen to include many HPV-positive specimens. The reference standard was a combination of HC2 and Onclarity results for HPV detection and histologic diagnosis of controls (less than cervical intraepithelial neoplasia grade 2 [

  18. Assessment of a New Lower-Cost Real-Time PCR Assay for Detection of High-Risk Human Papillomavirus: Useful for Cervical Screening in Limited-Resource Settings?

    PubMed

    Fokom Domgue, Joel; Schiffman, Mark; Wentzensen, Nicolas H; Gage, Julia C; Castle, Philip E; Raine-Bennett, Tina R; Fetterman, Barbara; Lorey, Thomas; Poitras, Nancy E; Befano, Brian; Xie, Yi; Miachon, Lais S; Dean, Michael

    2017-08-01

    Inexpensive and easy-to-perform human papillomavirus (HPV) tests are needed for primary cervical cancer screening in lower-resource regions. In a convenience sample of 516 residual exfoliative cervical specimens from the Kaiser Permanente Northern California and U.S. National Cancer Institute Persistence and Progression Study, we assessed the agreement and clinical performance of a simple, inexpensive real-time PCR assay for the detection of 13 carcinogenic HPV types (the H13 assay; Hybribio, Hong Kong) that is marketed in limited-resource settings compared to previous testing by the Hybrid Capture 2 assay (HC2; Qiagen, Germantown, MD) and the Onclarity assay (BD Diagnostics, Sparks, MD). The test set was chosen to include many HPV-positive specimens. The reference standard was a combination of HC2 and Onclarity results for HPV detection and histologic diagnosis of controls (less than cervical intraepithelial neoplasia grade 2 [

  19. Simulated Holograms: A Simple Introduction to Holography.

    ERIC Educational Resources Information Center

    Dittmann, H.; Schneider, W. B.

    1992-01-01

    Describes a project that uses a computer and a dot matrix printer to simulate the holographic recording process of simple object structures. The process' four steps are (1) superposition of waves; (2) representing the superposition of a plane reference wave on the monitor screen; (3) photographic reduction of the images; and (4) reconstruction of…

  20. "Finding the Right FIT": Rural Patient Preferences for Fecal Immunochemical Test (FIT) Characteristics.

    PubMed

    Pham, Robyn; Cross, Suzanne; Fernandez, Bianca; Corson, Kathryn; Dillon, Kristen; Yackley, Coco; Davis, Melinda M

    2017-01-01

    Colorectal cancer (CRC) is the third leading cause of cancer death in the United States, yet 1 in 3 Americans have never been screened for CRC. Annual screening using fecal immunochemical tests (FITs) is often a preferred modality in populations experiencing CRC screening disparities. Although multiple studies evaluate the clinical effectiveness of FITs, few studies assess patient preferences toward kit characteristics. We conducted this community-led study to assess patient preferences for FIT characteristics and to use study findings in concert with clinical effectiveness data to inform regional FIT selection. We collaborated with local health system leaders to identify FITs and recruit age eligible (50 to 75 years), English or Spanish speaking community members. Participants completed up to 6 FITs and associated questionnaires and were invited to participate in a follow-up focus group. We used a sequential explanatory mixed-methods design to assess participant preferences and rank FIT kits. First, we used quantitative data from user testing to measure acceptability, ease of completion, and specimen adequacy through a descriptive analysis of 1) fixed response questionnaire items on participant attitudes toward and experiences with FIT kits, and 2) a clinical assessment of adherence to directions regarding collection, packaging, and return of specimens. Second, we analyzed qualitative data from focus groups to refine FIT rankings and gain deeper insight into the pros and cons associated with each tested kit. Seventy-six FITs were completed by 18 participants (Range, 3 to 6 kits per participant). Over half (56%, n = 10) of the participants were Hispanic and 50% were female (n = 9). Thirteen participants attended 1 of 3 focus groups. Participants preferred FITs that were single sample, used a probe and vial for sample collection, and had simple, large-font instructions with colorful pictures. Participants reported challenges using paper to catch samples, had difficulty labeling tests, and emphasized the importance of having care team members provide verbal instructions on test completion and follow-up support for patients with abnormal results. FIT rankings from most to least preferred were OC-Light, Hemosure iFOB Test, InSure FIT, QuickVue, OneStep+, and Hemoccult ICT. FIT characteristics influenced patient's perceptions of test acceptability and feasibility. Health system leaders, payers, and clinicians should select FITs that are both clinically effective and incorporate patient preferred test characteristics. Consideration of patient preferences may facilitate FIT return, especially in populations at higher risk for experiencing CRC screening disparities. © Copyright 2017 by the American Board of Family Medicine.

  1. A Smartphone App to Screen for HIV-Related Neurocognitive Impairment

    PubMed Central

    Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan

    2014-01-01

    Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624

  2. Diagnostic accuracy of blood sucrose as a screening test for equine gastric ulcer syndrome (EGUS) in adult horses.

    PubMed

    Hewetson, Michael; Sykes, Ben William; Hallowell, Gayle Davina; Tulamo, Riitta-Mari

    2017-03-11

    Equine gastric ulcer syndrome (EGUS) is common in adult horses, particularly those involved in performance disciplines. Currently, detection of EGUS by gastroscopy is the only reliable ante mortem method for definitive diagnosis; however it is unsuitable as a screening test because it is expensive, time consuming, and is not readily available to most veterinarians. Sucrose permeability testing represents a simple, economical alternative to gastroscopy for screening purposes, and the feasibility of this approach in the horse has been previously reported. The aim of this study was to determine the diagnostic accuracy of blood sucrose as a screening test for EGUS in a large group of adult horses with and without naturally occurring gastric disease. One hundred and one adult horses with or without naturally occurring gastric ulceration were studied. The diagnostic accuracy of blood sucrose for diagnosis of gastric lesions (GL), glandular lesions (GDL), squamous lesions (SQL), and clinically significant lesions (CSL) at 45 and 90 min after administration of 1 g/kg of sucrose via nasogastric intubation was assessed using receiver operator characteristics (ROC) curves and calculating the area under the curve (AUC). For each lesion type, sucrose concentration in blood was compared to gastroscopy, as the gold standard, and sensitivities (Se) and specificities (Sp) were calculated across a range of sucrose concentrations. Ulcer grading was performed blindly by one observer; and the results were validated by comparing them with that of two other observers, and calculating the level of agreement. Cut-off values were selected manually to optimize Se. The prevalence of GL, GDL, SQL, and CSL was 83, 70, 53 and 58% respectively. At the selected cut-offs, Se ranged from 51 to 79% and Sp ranged from 43 to 72%, depending upon the lesion type and time of sampling. Blood sucrose is neither a sensitive or specific test for detecting EGUS in this population of adult horses with naturally occurring gastric ulceration. Further studies aimed at evaluating the performance characteristics of the test in different study populations are warranted. Given the limitations of endoscopy, due consideration should also be given to alternative methods for comparison of blood sucrose with a gold standard.

  3. A pictorial Sleepiness and Sleep Apnoea Scale to recognize individuals with high risk for obstructive sleep apnea syndrome.

    PubMed

    Edelmann, Cathrin; Ghiassi, Ramesh; Vogt, Deborah R; Partridge, Martyn R; Khatami, Ramin; Leuppi, Jörg D; Miedinger, David

    2017-01-01

    The aim of this study was to evaluate the validity of a new pictorial form of a screening test for obstructive sleep apnea syndrome (OSAS) - the pictorial Sleepiness and Sleep Apnoea Scale (pSSAS). Validation was performed in a sample of patients admitted to sleep clinics in the UK and Switzerland. All study participants were investigated with objective sleep tests such as full-night-attended polysomnography or polygraphy. The pSSAS was validated by taking into account the individual result of the sleep study, sleep-related questionnaires and objective parameters such as body mass index (BMI) or neck circumference. Different scoring schemes of the pSSAS were evaluated, and an internal validation was undertaken. The full data set consisted of 431 individuals (234 patients from the UK, 197 patients from Switzerland). The pSSAS showed good predictive performance for OSAS with an area under the curve between 0.77 and 0.81 depending on which scoring scheme was used. The subscores of the pSSAS had a moderate-to-strong correlation with widely used screening questionnaires for OSAS or excessive daytime sleepiness as well as with BMI and neck circumference. The pSSAS can be used to select patients with a high probability of having OSAS. Due to its simple pictorial design with short questions, it might be suitable for screening in populations with low health literacy and in non-native English or German speakers.

  4. Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  5. Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.

    PubMed

    Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G

    2017-08-01

    Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.

  6. The Development of a Novel, Validated, Rapid and Simple Method for the Detection of Sarcocystis fayeri in Horse Meat in the Sanitary Control Setting.

    PubMed

    Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro

    2016-01-01

    Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.

  7. Screening plant derived dietary phenolic compounds for bioactivity related to cardiovascular disease.

    PubMed

    Croft, Kevin D; Yamashita, Yoko; O'Donoghue, Helen; Shirasaya, Daishi; Ward, Natalie C; Ashida, Hitoshi

    2018-04-01

    The potential health benefits of phenolic acids found in food and beverages has been suggested from a number of large population studies. However, the mechanism of how these compounds may exert biological effects is less well established. It is also now recognised that many complex polyphenols in the diet are metabolised to simple phenolic acids which can be taken up in the circulation. In this paper a number of selected phenolic compounds have been tested for their bioactivity in two cell culture models. The expression and activity of endothelial nitric oxide synthase (eNOS) in human aortic endothelial cells and the uptake of glucose in muscle cells. Our data indicate that while none of the compounds tested had a significant effect on eNOS expression or activation in endothelial cells, several of the compounds increased glucose uptake in muscle cells. These compounds also enhanced the translocation of the glucose transporter GLUT4 to the plasma membrane, which may explain the observed increase in cellular glucose uptake. These results indicate that simple cell culture models may be useful to help understand the bioactivity of phenolic compounds in relation to cardiovascular protection. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A simple clot based assay for detection of procoagulant cell-derived microparticles.

    PubMed

    Patil, Rucha; Ghosh, Kanjaksha; Shetty, Shrimati

    2016-05-01

    Cell-derived microparticles (MPs) are important biomarkers in many facets of medicine. However, the MP detection methods used till date are costly and time consuming. The main aim of this study was to standardize an in-house clot based screening method for MP detection which would not only be specific and sensitive, but also inexpensive. Four different methods of MP assessment were performed and the results correlated. Using the flow cytometry technique as the gold standard, 25 samples with normal phosphatidylserine (PS) expressing MP levels and 25 samples with elevated levels were selected, which was cross checked by the commercial STA Procoag PPL clotting time (CT) assay. A simple recalcification time and an in-house clot assay were the remaining two tests. The in-house test measures the CT after the addition of calcium chloride to MP rich plasma, following incubation with Russell viper venom and phospholipid free plasma. The CT obtained by the in-house assay significantly correlated with the results obtained by flow cytometry (R2=0.87, p<0.01). Though preliminary, the in-house assay seems to be efficient, inexpensive and promising. It could definitely be utilized routinely for procoagulant MP assessment in various clinical settings.

  9. Screening and monitoring microbial xenobiotics' biodegradation by rapid, inexpensive and easy to perform microplate UV-absorbance measurements.

    PubMed

    Herzog, Bastian; Lemmer, Hilde; Horn, Harald; Müller, Elisabeth

    2014-02-22

    Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. In laboratory setups, xenobiotics concentrations above 1.0 mg L(-1) without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum.

  10. Screening and monitoring microbial xenobiotics’ biodegradation by rapid, inexpensive and easy to perform microplate UV-absorbance measurements

    PubMed Central

    2014-01-01

    Background Evaluation of xenobiotics biodegradation potential, shown here for benzotriazoles (corrosion inhibitors) and sulfamethoxazole (sulfonamide antibiotic) by microbial communities and/or pure cultures normally requires time intensive and money consuming LC/GC methods that are, in case of laboratory setups, not always needed. Results The usage of high concentrations to apply a high selective pressure on the microbial communities/pure cultures in laboratory setups, a simple UV-absorbance measurement (UV-AM) was developed and validated for screening a large number of setups, requiring almost no preparation and significantly less time and money compared to LC/GC methods. This rapid and easy to use method was evaluated by comparing its measured values to LC-UV and GC-MS/MS results. Furthermore, its application for monitoring and screening unknown activated sludge communities (ASC) and mixed pure cultures has been tested and approved to detect biodegradation of benzotriazole (BTri), 4- and 5-tolyltriazole (4-TTri, 5-TTri) as well as SMX. Conclusions In laboratory setups, xenobiotics concentrations above 1.0 mg L-1 without any enrichment or preparation could be detected after optimization of the method. As UV-AM does not require much preparatory work and can be conducted in 96 or even 384 well plate formats, the number of possible parallel setups and screening efficiency was significantly increased while analytic and laboratory costs were reduced to a minimum. PMID:24558966

  11. Andriod Device-Based Cervical Cancer Screening for Resource-Poor Settings.

    PubMed

    Kudva, Vidya; Prasad, Keerthana; Guruvare, Shyamala

    2018-05-18

    Visual inspection with acetic acid (VIA) is an effective, affordable and simple test for cervical cancer screening in resource-poor settings. But considerable expertise is needed to differentiate cancerous lesions from normal lesions, which is lacking in developing countries. Many studies have attempted automation of cervical cancer detection from cervix images acquired during the VIA process. These studies used images acquired through colposcopy or cervicography. However, colposcopy is expensive and hence is not feasible as a screening tool in resource-poor settings. Cervicography uses a digital camera to acquire cervix images which are subsequently sent to experts for evaluation. Hence, cervicography does not provide a real-time decision of whether the cervix is normal or not, during the VIA examination. In case the cervix is found to be abnormal, the patient may be referred to a hospital for further evaluation using Pap smear and/or biopsy. An android device with an inbuilt app to acquire images and provide instant results would be an obvious choice in resource-poor settings. In this paper, we propose an algorithm for analysis of cervix images acquired using an android device, which can be used for the development of decision support system to provide instant decision during cervical cancer screening. This algorithm offers an accuracy of 97.94%, a sensitivity of 99.05% and specificity of 97.16%.

  12. Role of gynecologists in reproductive education of adolescent girls in Hungary.

    PubMed

    Varga-Tóth, Andrea; Paulik, Edit

    2015-05-01

    The aim of this study was to assess whether the socioeconomic characteristics of adolescent girls, their knowledge about cervical cancer screening, and their sexual activity are associated with whether or not they have already visited a gynecologist. A self-administered questionnaire-based study was performed among secondary school girls (n = 589) who participated in professional education provided by a pediatric and adolescent gynecologist. The questionnaire comprised sociodemographic characteristics, sexual activity, knowledge on contraceptive methods, cervical screening and sources of their knowledge. Simple descriptive statistics, χ(2) and one-way-anova tests, multivariate logistic regression analysis and Pearson correlation were applied. All statistical analyses were carried out using spss 17.0 for Windows. A total of 50.3% of adolescent girls had already had a sexual contact. Half of the sexually active participants had already visited a gynecologist, and most of them did so due to some kind of complaint. The overall knowledge about cervical screening was quite low; higher knowledge was found among those having visited a gynecologist. Adolescent girls' knowledge on cervical screening was improved by previous visits to a gynecologist. The participation of an expert--a gynecologist--in a comprehensive sexual education program of teenage girls is of high importance in Hungary. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  13. Simultaneous Detection of Three Phosphodiesterase Type 5 Inhibitors and Eight of Their Analogs in Lifestyle Products and Screening for Adulterants by High-Performance Thin-Layer Chromatography.

    PubMed

    Do, Tiên T K; Theocharis, Grigorios; Reich, Eike

    2015-01-01

    An HPTLC method is proposed to permit effective screening for the presence of three phosphodiesterase type 5 inhibitors (PDE5-Is; sildenafil, vardenafil, and tadalafil) and eight of their analogs (hydroxyacetildenafil, homosildenafil, thiohomosildenafil, acetildenafil, acetaminotadalafil, propoxyphenyl hydroxyhomosildenafil, hydroxyhomosildenafil, and hydroxythiohomosildenafil) in finished products, including tablets, capsules, chocolate, instant coffee, syrup, and chewing gum. For all the finished products, the same simple sample preparation may be applied: ultrasound-assisted extraction in 10 mL methanol for 30 min followed by centrifugation. The Rf values of individual HPTLC bands afford preliminary identification of potential PDE5-Is. Scanning densitometry capabilities enable comparison of the unknown UV spectra with those of known standard compounds and allow further structural insight. Mass spectrometric analysis of the material derived from individual zones supplies an additional degree of confidence. Significantly, the proposed screening technique allows focus on the already known PDE5 Is and provides a platform for isolation and chemical categorization of the newly-synthesized analogs. Furthermore, the scope could be expanded to other therapeutic categories (e.g., analgesics, antidiabetics, and anorexiants) that are occasionally coadulterated along with the PDE5-Is. The method was successfully applied to screening of 45 commercial lifestyle products. Of those, 31 products tested positive for at least one illegal component (sildenafil, tadalafil, propoxyphenyl hydroxyhomosildenafil, or dimethylsildenafil).

  14. Cost-effectiveness of different screening strategies for osteoporosis in postmenopausal women.

    PubMed

    Nayak, Smita; Roberts, Mark S; Greenspan, Susan L

    2011-12-06

    The best strategies to screen postmenopausal women for osteoporosis are not clear. To identify the cost-effectiveness of various screening strategies. Individual-level state-transition cost-effectiveness model. Published literature. U.S. women aged 55 years or older. Lifetime. Payer. Screening strategies composed of alternative tests (central dual-energy x-ray absorptiometry [DXA], calcaneal quantitative ultrasonography [QUS], and the Simple Calculated Osteoporosis Risk Estimation [SCORE] tool) initiation ages, treatment thresholds, and rescreening intervals. Oral bisphosphonate treatment was assumed, with a base-case adherence rate of 50% and a 5-year on/off treatment pattern. Incremental cost-effectiveness ratios (2010 U.S. dollars per quality-adjusted life-year [QALY] gained). At all evaluated ages, screening was superior to not screening. In general, quality-adjusted life-days gained with screening tended to increase with age. At all initiation ages, the best strategy with an incremental cost-effectiveness ratio (ICER) of less than $50,000 per QALY was DXA screening with a T-score threshold of -2.5 or less for treatment and with follow-up screening every 5 years. Across screening initiation ages, the best strategy with an ICER less than $50,000 per QALY was initiation of screening at age 55 years by using DXA -2.5 with rescreening every 5 years. The best strategy with an ICER less than $100,000 per QALY was initiation of screening at age 55 years by using DXA with a T-score threshold of -2.0 or less for treatment and then rescreening every 10 years. No other strategy that involved treatment of women with osteopenia had an ICER less than $100,000 per QALY. Many other strategies, including strategies with SCORE or QUS prescreening, were also cost-effective, and in general the differences in effectiveness and costs between evaluated strategies was small. Probabilistic sensitivity analysis did not reveal a consistently superior strategy. Data were primarily from white women. Screening initiation at ages younger than 55 years were not examined. Only osteoporotic fractures of the hip, vertebrae, and wrist were modeled. Many strategies for postmenopausal osteoporosis screening are effective and cost-effective, including strategies involving screening initiation at age 55 years. No strategy substantially outperforms another. National Center for Research Resources.

  15. A Comparison of Parallel and Integrated Models for Implementation of Routine HIV Screening in a Large, Urban Emergency Department.

    PubMed

    Hankin, Abigail; Freiman, Heather; Copeland, Brittney; Travis, Natasha; Shah, Bijal

    2016-01-01

    This study compared two approaches for implementation of non-targeted HIV screening in the emergency department (ED): (1) designated HIV counselors screening in parallel with ED care and (2) nurse-based screening integrated into patient triage. A retrospective analysis was performed to compare parallel and integrated screening models using data from the first 12 months of each program. Data for the parallel screening model were extracted from information collected by HIV test counselors and the electronic medical record (EMR). Integrated screening model data were extracted from the EMR and supplemented by data collected by HIV social workers during patient interaction. For both programs, data included demographics, HIV test offer, test acceptance or declination, and test result. A Z-test between two proportions was performed to compare screening frequencies and results. During the first 12 months of parallel screening, approximately 120,000 visits were made to the ED, with 3,816 (3%) HIV tests administered and 65 (2%) new diagnoses of HIV infection. During the first 12 months of integrated screening, 111,738 patients were triaged in the ED, with 16,329 (15%) patients tested and 190 (1%) new diagnoses. Integrated screening resulted in an increased frequency of HIV screening compared with parallel screening (0.15 tests per ED patient visit vs. 0.03 tests per ED patient visit, p<0.001) and an increase in the absolute number of new diagnoses (190 vs. 65), representing a slight decrease in the proportion of new diagnoses (1% vs. 2%, p=0.007). Non-targeted, integrated HIV screening, with test offer and order by ED nurses during patient triage, is feasible and resulted in an increased frequency of HIV screening and a threefold increase in the absolute number of newly identified HIV-positive patients.

  16. Videotex: Words on the TV Screen. Viewdata, Teletext and the Rest.

    ERIC Educational Resources Information Center

    Howkins, John, Ed.

    1979-01-01

    This theme issue focuses on the development of telephone-based videotex systems that use television sets and the telephone with the addition of a simple keyboard to access banks of information available on computers and to receive information in print on the television screen. A series of articles are included on Prestel, a telephone-based…

  17. Eating Disorders in Graduate Students: Exploring the SCOFF Questionnaire as a Simple Screening Tool

    ERIC Educational Resources Information Center

    Parker, Sarah C.; Lyons, John; Bonner, Julia

    2005-01-01

    The results of several studies have established the validity of the SCOFF questionnaire (a 5-question screening tool for eating disorders), but researchers need to explore further replicability using the US version in the graduate school population. In this study, the authors asked 335 graduate students attending the Northwestern student health…

  18. Risks of Prostate Cancer Screening

    MedlinePlus

    ... decrease the risk of dying from cancer. Scientists study screening tests to find those with the fewest risks and ... or routine screening test for prostate cancer. Screening tests for prostate cancer are under study, and there are screening clinical trials taking place ...

  19. [Hyperthyroidism in family medecine].

    PubMed

    Bernier, M; Varlet, E

    2017-01-01

    Hyperthyroidism and sub-hyperthyroidism are common illnesses. Their diagnosis and their treatment are accessible to the general practitioner in the any great majority of the cases. A careful clinical examination already allows to direct the diagnosis. The development is simple and consists of a blood dosage, an ultrasound and sometimes a scintigraphy. Rare cases and severe forms are to be recognized and to refer to specialized centre. The treatment of first intention are betablockers. The comorbidities are cardiovascular (atrial fibrillation mostly) and skeletal (osteoporosis). Considering the increase of cardiovascular risks and the fracture risk in this pathology, the screening is especially indicated for women above 65 years. This screening is simple and little invasive, it consists of the annual dosage of the TSH.

  20. Nonlocal Models of Cosmic Acceleration

    NASA Astrophysics Data System (ADS)

    Woodard, R. P.

    2014-02-01

    I review a class of nonlocally modified gravity models which were proposed to explain the current phase of cosmic acceleration without dark energy. Among the topics considered are deriving causal and conserved field equations, adjusting the model to make it support a given expansion history, why these models do not require an elaborate screening mechanism to evade solar system tests, degrees of freedom and kinetic stability, and the negative verdict of structure formation. Although these simple models are not consistent with data on the growth of cosmic structures many of their features are likely to carry over to more complicated models which are in better agreement with the data.

  1. [The Battelle developmental inventory screening test for early detection of developmental disorders in cerebral palsy].

    PubMed

    Moraleda-Barreno, E; Romero-López, M; Cayetano-Menéndez, M J

    2011-12-01

    Cerebral palsy is usually associated with motor, cognitive, and language deficits, and with other disorders that cause disability in daily living skills, personal independence, social interaction and academic activities. Early detection of these deficits in the clinical setting is essential to anticipate and provide the child with the necessary support for adapting to the environment in all possible areas. The main objective of this study is to demonstrate that these deficits can be detected at an early age and comprehensively through the use of a brief development scale. We studied 100 children between 4 and 70 months old, half of them with cerebral palsy and the other half without any disorder. All subjects were evaluated using the Battelle Developmental Inventory screening test. We compared the developmental quotients in both groups and between the subjects with different motor impairments, using a simple prospective ex post facto design. The test detected statistically significant differences between the clinical group and the control group at all age levels. Statistically significant differences were also found between tetraplegia and other motor disorders. There were no differences by gender. The deficit in development associated with cerebral palsy can be quantified at early ages through the use of a brief development scale, thus we propose that the systematic implementation of protocols with this screening tool would be helpful for treatment and early intervention. This would also help in anticipating and establishing the means for the multidisciplinary actions required, and could provide guidance to other health professionals, to provide adequate school, social, and family support,. Copyright © 2011 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  2. Detection of impaired glucose tolerance and undiagnosed type 2 diabetes in UK South Asians: an effective screening strategy.

    PubMed

    Hanif, M W; Valsamakis, G; Dixon, A; Boutsiadis, A; Jones, A F; Barnett, A H; Kumar, S

    2008-09-01

    We tested a stepwise, community-based screening strategy for glucose intolerance in South Asians using a health questionnaire in conjunction with body mass index (BMI). Anthropometric measurements (waist and hip circumference, sagittal diameter and percentage body fat) were then conducted in a hospital setting followed by an oral glucose tolerance test (OGTT) to identify subjects at the highest risk and analyse the factors predicting that risk. A health questionnaire was administered to 435 subjects in a community setting and BMI was measured. Subjects were graded by a risk score based on the health questionnaire as high, medium and low. Subjects with high and medium risk scores and a representative sample of those with low scores had anthropometric measurements in hospital followed by an OGTT. In total, 205 (47%) of the subjects had an OGTT performed. In total, 48.7% of the subjects tested with an OGTT had evidence of glucose dysregulation: 20% had diabetes and 28.7% had impaired glucose tolerance (IGT). Logistic regression model explained 49.1% of the total variability. The significant predictors of diabetes and IGT were Blood Glucose Monitoring Strips (BMI), random blood glucose (BM), sibling with diabetes and presence of diagnosed hypertension or ischaemic disease. Most of these predictors along with other heredity diabetes factors create a composite score, with high predictability, as the receiver operating curve analysis shows. We describe a simple, stepwise strategy in a community setting, based on a health questionnaire and anthropometric measurements, to explain about 50% of cases with IGT and diabetes and diagnose about 50% of cases from the population screened. We have also identified factors that predict the risk.

  3. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    PubMed

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Introducing a simple model system for binding studies of known and novel inhibitors of AMPK: a therapeutic target for prostate cancer.

    PubMed

    Kumar, Rakesh; Maurya, Ranjana; Saran, Shweta

    2018-02-23

    Prostate cancer (PC) is one of the leading cancers in men, raising a serious health issue worldwide. Due to lack of suitable biomarker, their inhibitors and the platform for testing those inhibitors result in poor prognosis of PC. AMP-activated protein kinase (AMPK) is a highly conserved protein kinase found in eukaryotes that is involved in growth and development, and also acts as a therapeutic target for PC. The aim of the present study is to identify novel potent inhibitors of AMPK and propose a simple cellular model system for understanding its biology. Structural modelling and MD simulations were performed to construct and refine the 3D models of Dictyostelium and human AMPK. Binding mechanisms of different drug compounds were studied by performing molecular docking, molecular dynamics and MM-PBSA methods. Two novel drugs were isolated having higher binding affinity over the known drugs and hydrophobic forces that played a key role during protein-ligand interactions. The study also explored the simple cellular model system for drug screening and understanding the biology of a therapeutic target by performing in vitro experiments.

  5. Attracted by a magnet: Exploration behaviour of rodents in the presence of magnetic objects.

    PubMed

    Malewski, Sandra; Malkemper, E Pascal; Sedláček, František; Šumbera, Radim; Caspar, Kai R; Burda, Hynek; Begall, Sabine

    2018-06-01

    Magnetosensitivity is widespread among animals with rodents being the most intensively studied mammalian group. The available behavioural assays for magnetoreception are time-consuming, which impedes screens for treatment effects that could characterize the enigmatic magnetoreceptors. Here, we present a fast and simple approach to test if an animal responds to magnetic stimuli: the magnetic object assay (MOA). The MOA focuses on investigating an animal's spontaneous exploration behaviour in the presence of a bar magnet compared to a demagnetised control. We present consistently longer exploration of the magnet in three different rodent species: Ansell's mole-rat (Fukomys anselli), C57BL/6J laboratory mouse, and naked mole-rat (Heterocephalus glaber). For the naked mole-rat this is the first report that this species reacts on magnetic stimuli. We conclude that the MOA holds the potential to screen if an animal responds to magnetic stimuli, indicating the possession of a magnetic sense. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. [Long distance-PCR for detection of factor VIII gene inversion in patients with severe hemophilia A].

    PubMed

    Ding, Pei-Fang; Sun, Wei-Sheng; Wang, Qin-You; Liu, De-Chun; Zhang, Xue-Qin; Teng, Bin; Shen, Fa-Kui

    2003-08-01

    The aim of current study was to detect intron 22 inversion of factor VIII gene in severe hemophilia A (HA) patients and screen the carriers of the gene inversion. Fifty-five cases of severe HA were involved and factor VIII gene inversion was detected and identified by long distance-PCR (LD-PCR) and 0.6% agarose gel electrophoresis. The 11 kb and 12 kb bands indicate the factor VIII gene inversion and non-inversion, respectively. Occurring of both 11 kb and 12 kb bands indicates a carrier of the inversion. The results showed that factor VIII gene inversion existed in 22 out of 55 cases, which accounted for about 40% of total detected patients. Five carriers of factor VIII gene inversion were diagnosed from the members in 15 families. In conclusion, LD-PCR assay is a simple, rapid and accurate method for detection of factor VIII gene inversion, and this approach is helpful in screening, carrier testing, and prenatal diagnosis of severe hemophilia A.

  7. Diagnosis of schistosomiasis japonica with interfacial co-assembly-based multi-channel electrochemical immunosensor arrays

    NASA Astrophysics Data System (ADS)

    Deng, Wangping; Xu, Bin; Hu, Haiyan; Li, Jianyong; Hu, Wei; Song, Shiping; Feng, Zheng; Fan, Chunhai

    2013-05-01

    Schistosomiasis control remains to be an important and challenging task in the world. However, lack of quick, simple, sensitive and specific sero-diagnostic test is still a hurdle in the control practice. The commonly employed enzyme-linked immuno-sorbent assay (ELISA) relies on the native soluble egg antigen (SEA) that is limited in supply. Here we developed an electrochemical immunosensor array (ECISA) assay with an interfacial co-assembly strategy. A recombinant Schistosoma japonicum (Sj) calcium-binding protein (SjE16) was used as a principal antigen, while the SEA as a minor, co-assembling agent, with a ratio of 8:1 (SjE16: SEA, Sj16EA), which was co-immobilized on a disposable 16-channel screen-printed carbon electrode array. A portable electrochemical detector was employed to detect antibodies in serum samples. The sensitivity of ECISA reached 100% with minimal cross-reactions. Therefore, we have demonstrated that this rapid, sensitive and specific ECISA technique has the potential to perform large-scale on-site screening of Sj infection.

  8. Effect of an administrative intervention on rates of screening for domestic violence in an urban emergency department.

    PubMed

    Larkin, G L; Rolniak, S; Hyman, K B; MacLeod, B A; Savage, R

    2000-09-01

    This study measured the effects of an administrative intervention on health care provider compliance with universal domestic violence screening protocols. We used a simple, interrupted-time-series design in a stratified random sample of female emergency department patients 18 years or older (n = 1638 preintervention, n = 1617 postintervention). The intervention was a 4-tiered hospital-approved disciplinary action, and the primary outcome was screening compliance. Preintervention and postintervention screening rates were 29.5% and 72.8%, respectively. Before the intervention, screening was worse on the night shift (odds ratio [OR] = 0.46, 95% confidence interval [CI] = 0.31, 0.68) and with psychiatric patients (OR = 0.34, 95% CI = 0.14, 0.85); after the intervention, no previous screening barriers remained significant. An administrative intervention significantly enhanced compliance with universal domestic violence screening.

  9. Mapping the neglected space: gradients of detection revealed by virtual reality.

    PubMed

    Dvorkin, Assaf Y; Bogey, Ross A; Harvey, Richard L; Patton, James L

    2012-02-01

    Spatial neglect affects perception along different dimensions. However, there is limited availability of 3-dimensional (3D) methods that fully map out a patient's volume of deficit, although this could guide clinical management. To test whether patients with neglect exhibit simple contralesional versus complex perceptual deficits and whether deficits are best described using Cartesian (rectangular) or polar coordinates. Seventeen right-hemisphere persons with stroke (8 with a history of neglect) and 9 healthy controls were exposed to a 3D virtual environment. Targets placed in a dense array appeared one at a time in various locations. When tested using rectangular array of targets, subjects in the neglect group exhibited complex asymmetries across several dimensions in both reaction time and target detection rates. Paper-and-pencil tests only detected neglect in 4 of 8 of these patients. When tested using polar array of targets, 2 patients who initially appeared to perform poorly in both left and near space only showed a simple left-side asymmetry that depended almost entirely on the angle from the sagittal plane. A third patient exhibited left neglect irrespective of the arrangements of targets used. An idealized model with pure dependence on the polar angle demonstrated how such deficits could be misconstrued as near neglect if one uses a rectangular array. Such deficits may be poorly detected by paper-and-pencil tests and even by computerized tests that use regular screens. Assessments that incorporate 3D arrangements of targets enable precise mapping of deficient areas and detect subtle forms of neglect whose identification may be relevant to treatment strategies.

  10. A concise evidence-based physical examination for diagnosis of acromioclavicular joint pathology: a systematic review.

    PubMed

    Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank

    2018-02-01

    The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint corticosteroid injection may be an appropriate new standard for treatment and surgical decision-making. II - Systematic Review.

  11. Cancer Screening: How Do Screening Tests Become Standard Tests?

    MedlinePlus

    ... more groups. The people in one group (the control group ) may be given a standard screening test (if one exists) or no screening test. The ... for the human papillomavirus (HPV) and those who test negative for HPV. The ... Case-control studies Case-control studies are like cohort studies ...

  12. Performance on physical function tests and the risk of fractures and admissions: Findings from a national health screening of 557,648 community-dwelling older adults.

    PubMed

    Chun, So Hyun; Cho, Belong; Yang, Hyung-Kook; Ahn, Eunmi; Han, Min Kyu; Oh, Bumjo; Shin, Dong Wook; Son, Ki Young

    Falls and fractures in older adults are often preventable, yet remain major health concerns as comprehensive physical function assessment may not be readily available. This study investigated whether simple timed up and go test (TUG) and unipedal stance test (UST) are effective in identifying people with an increased risk of fractures, femoral fractures, or admissions due to femoral fractures. Community-dwelling Korean older adults aged 66 years participated in the Korean National Screening Program for the Transitional Ages (n=557,648) between 2007 and 2010. Overall fractures, femoral fractures, and admissions due to femoral fracture during this period were outcome measures. The outcome measures were overall fractures, femoral fractures, and admissions due to femoral fracture after the health screening. The associations between inferior physical function test results and outcome measures were evaluated. A total of 523,502 subjects were followed-up for a mean period of 1.42 years, which resulted in 12,965 subjects with any fractures. Fracture data were retrieved from medical claims record. Subjects who performed poorly on one or both of the two physical function tests experienced higher number of overall fractures (aHR 1.21, 95% CI: 1.16-1.26), femoral fractures (aHR 1.80, 95% CI: 1.59-2.17), and admissions due to femoral fractures (aHR 1.85, 95% CI: 1.55-2.22) as compared to subjects with normal results on both tests. Combining TUG and UST was not superior to performing UST alone in predicting the increased risk of overall fractures (p=0.347), femoral fractures (p=0.402) or admissions due to femoral fractures (p=0.774). Poor performance on physical performance tests is associated with a higher risk of overall fractures, femoral fractures and admissions due to femoral fractures. The TUG and UST can be used to identify community-dwelling older individuals who are more vulnerable to fractures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Improving compliance to colorectal cancer screening using blood and stool based tests in patients refusing screening colonoscopy in Germany.

    PubMed

    Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram

    2014-10-17

    Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.

  14. A Simple Double-Source Model for Interference of Capillaries

    ERIC Educational Resources Information Center

    Hou, Zhibo; Zhao, Xiaohong; Xiao, Jinghua

    2012-01-01

    A simple but physically intuitive double-source model is proposed to explain the interferogram of a laser-capillary system, where two effective virtual sources are used to describe the rays reflected by and transmitted through the capillary. The locations of the two virtual sources are functions of the observing positions on the target screen. An…

  15. The human false-negative rate of rescreening Pap tests. Measured in a two-arm prospective clinical trial.

    PubMed

    Renshaw, A A; Lezon, K M; Wilbur, D C

    2001-04-25

    Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation. The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology. The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low. Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.

  16. A new early cognitive screening measure to detect cognitive side-effects of electroconvulsive therapy?

    PubMed

    Martin, Donel M; Katalinic, Natalie; Ingram, Anna; Schweitzer, Isaac; Smith, Deidre J; Hadzi-Pavlovic, Dusan; Loo, Colleen K

    2013-12-01

    Cognitive side-effects from electroconvulsive therapy (ECT) can be distressing for patients and early detection may have an important role in guiding treatment decisions over the ECT course. This prospective study examined the utility of an early cognitive screening battery for predicting cognitive side-effects which develop later in the ECT course. The screening battery, together with the Mini Mental Status Examination (MMSE), was administered to 123 patients at baseline and after 3 ECT treatments. A more detailed cognitive battery was administered at baseline, after six treatments (post ECT 6) and after the last ECT treatment (post treatment) to assess cognitive side-effects across several domains: global cognition, anterograde memory, executive function, speed and concentration, and retrograde memory. Multivariate analyses examined the predictive utility of change on items from the screening battery for later cognitive changes at post ECT 6 and post treatment. Results showed that changes on a combination of items from the screening battery were predictive of later cognitive changes at post treatment, particularly for anterograde memory (p < 0.01), after controlling for patient and treatment factors. Change on the MMSE predicted cognitive changes at post ECT 6 but not at post treatment. A scoring method for the new screening battery was tested for discriminative ability in a sub-sample of patients. This study provides preliminary evidence that a simple and easy-to-administer measure may potentially be used to help guide clinical treatment decisions to optimise efficacy and cognitive outcomes. Further development of this measure and validation in a more representative ECT clinical population is required. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Measurement of urinary metanephrines to screen for pheochromocytoma in an unselected hospital referral population

    PubMed Central

    Brain, Keith L.; Kay, Jonathan; Shine, Brian

    2009-01-01

    Background Despite the rarity of pheochromocytoma, the dangers of uncontrolled severe hypertension and the very effective surgical treatment of this condition mean that diagnosis is important. Urinary or plasma catecholamines or catecholamine-derivatives are commonly used to screen for pheochromocytomas prior to imaging. This study investigates whether derived measures obtained from 24-hour urinary metanephrine results, patient age and sex can better predict tumors in populations with a low pre-test probability. Methods This study takes a pragmatic approach by retrospectively studying the outcomes of an unselected population referred for urinary metanephrine testing (1819 patients) to a tertiary hospital laboratory, and investigates the usefulness of some simple derivative measures for detecting pheochromocytoma. Urinary 24-hour excretion of metanephrine, normetanephrine and 3-methoxytyramine were normalized by dividing by an age- and sex- specific reference range. The ability of products of these normalized measures to predict pheochromocytomas was assessed, compared to a gold standard of biopsy-confirmed tumor. Results The normalized product of urinary metanephrine and normetanephrine excretion (nMAD.nNMT) proved to be a highly sensitive (100%) and specific (99.1%) measure yielding a positive predictive value 82%. Receiver-operator characteristic curves were not improved by including the normalized 3-methoxytyramine concentrations in the product. nMAD.nNMT gave higher sensitivity and specificity than either test alone. Conclusion We suggest that nMAD.nNMT is a useful measure for identifying pheochromocytoma in a population with a low pre-test probability. PMID:16990424

  18. Mixture toxicity of wood preservative products in the fish embryo toxicity test.

    PubMed

    Coors, Anja; Dobrick, Jan; Möder, Monika; Kehrer, Anja

    2012-06-01

    Wood preservative products are used globally to protect wood from fungal decay and insects. We investigated the aquatic toxicity of five commercial wood preservative products, the biocidal active substances and some formulation additives contained therein, as well as six generic binary mixtures of the active substances in the fish embryo toxicity test (FET). Median lethal concentrations (LC50) of the single substances, the mixtures, and the products were estimated from concentration-response curves and corrected for concentrations measured in the test medium. The comparison of the experimentally observed mixture toxicity with the toxicity predicted by the concept of concentration addition (CA) showed less than twofold deviation for all binary mixtures of the active substances and for three of the biocidal products. A more than 60-fold underestimation of the toxicity of the fourth product by the CA prediction was detected and could be explained fully by the toxicity of one formulation additive, which had been labeled as a hazardous substance. The reason for the 4.6-fold underestimation of toxicity of the fifth product could not be explained unambiguously. Overall, the FET was found to be a suitable screening tool to verify whether the toxicity of formulated wood preservatives can reliably be predicted by CA. Applied as a quick and simple nonanimal screening test, the FET may support approaches of applying component-based mixture toxicity predictions within the environmental risk assessment of biocidal products, which is required according to European regulations. Copyright © 2012 SETAC.

  19. One simple DNA extraction device and its combination with modified visual loop-mediated isothermal amplification for rapid on-field detection of genetically modified organisms.

    PubMed

    Zhang, Miao; Liu, Yinan; Chen, Lili; Quan, Sheng; Jiang, Shimeng; Zhang, Dabing; Yang, Litao

    2013-01-02

    Quickness, simplicity, and effectiveness are the three major criteria for establishing a good molecular diagnosis method in many fields. Herein we report a novel detection system for genetically modified organisms (GMOs), which can be utilized to perform both on-field quick screening and routine laboratory diagnosis. In this system, a newly designed inexpensive DNA extraction device was used in combination with a modified visual loop-mediated isothermal amplification (vLAMP) assay. The main parts of the DNA extraction device included a silica gel membrane filtration column and a modified syringe. The DNA extraction device could be easily operated without using other laboratory instruments, making it applicable to an on-field GMO test. High-quality genomic DNA (gDNA) suitable for polymerase chain reaction (PCR) and isothermal amplification could be quickly isolated from plant tissues using this device within 15 min. In the modified vLAMP assay, a microcrystalline wax encapsulated detection bead containing SYBR green fluorescent dye was introduced to avoid dye inhibition and cross-contaminations from post-LAMP operation. The system was successfully applied and validated in screening and identification of GM rice, soybean, and maize samples collected from both field testing and the Grain Inspection, Packers, and Stockyards Administration (GIPSA) proficiency test program, which demonstrated that it was well-adapted to both on-field testing and/or routine laboratory analysis of GMOs.

  20. Simple many-body based screening mixing ansatz for improvement of G W /Bethe-Salpeter equation excitation energies of molecular systems

    NASA Astrophysics Data System (ADS)

    Ziaei, Vafa; Bredow, Thomas

    2017-11-01

    We propose a simple many-body based screening mixing strategy to considerably enhance the performance of the Bethe-Salpeter equation (BSE) approach for prediction of excitation energies of molecular systems. This strategy enables us to closely reproduce results of highly correlated equation of motion coupled cluster singles and doubles (EOM-CCSD) through optimal use of cancellation effects. We start from the Hartree-Fock (HF) reference state and take advantage of local density approximation (LDA) based random phase approximation (RPA) screening, denoted as W0-RPA@LDA with W0 as the dynamically screened interaction built upon LDA wave functions and energies. We further use this W0-RPA@LDA screening as an initial screening guess for calculation of quasiparticle energies in the framework of G0W0 @HF. The W0-RPA@LDA screening is further injected into the BSE. By applying such an approach on a set of 22 molecules for which the traditional G W /BSE approaches fail, we observe good agreement with respect to EOM-CCSD references. The reason for the observed good accuracy of this mixing ansatz (scheme A) lies in an optimal damping of HF exchange effect through the W0-RPA@LDA strong screening, leading to substantial decrease of typically overestimated HF electronic gap, and hence to better excitation energies. Further, we present a second multiscreening ansatz (scheme B), which is similar to scheme A with the exception that now the W0-RPA@HF screening is used in the BSE in order to further improve the overestimated excitation energies of carbonyl sulfide (COS) and disilane (Si2H6 ). The reason for improvement of the excitation energies in scheme B lies in the fact that W0-RPA@HF screening is less effective (and weaker than W0-RPA@LDA), which gives rise to stronger electron-hole effects in the BSE.

  1. Adherence to multiple cancer screening tests among women living in Appalachia Ohio

    PubMed Central

    Katz, Mira L.; Reiter, Paul L.; Young, Gregory S.; Pennell, Michael L.; Tatum, Cathy M.; Paskett, Electra D.

    2015-01-01

    Background There is a lack of information about the correlates of completing all three cancer screening tests among women living in Appalachia. Methods Cross-sectional telephone interviews were conducted (April-September 2013) among women (n=637) ages 51-75 from 12 Appalachia Ohio counties. Outcomes of within screening guidelines were verified by medical record. Multivariable logistic regression models identified correlates of being within guidelines for all three cancer screening tests. Results Screening rates were: mammography (32.1%), Pap test (36.1%), and a colorectal cancer test (30.1%). Only 8.6% of women were within guidelines for all tests. Having had a check-up in the past two years and having received a screening recommendation were significantly related to being within guidelines for all three tests (p<0.01). Participants with higher annual household incomes ($60,000+; OR=3.53, 95% CI: 1.49, 8.33) and conditions requiring regular medical visits (OR=3.16, 95% CI: 1.29, 7.74) were more likely to be within guidelines for all three screening tests. Conclusion Less than 10% of women had completed screening within guidelines for all three screening tests. Regular contact with the healthcare system and higher incomes were significant predictors of being within guidelines. Impact Within guidelines rates for the three recommended cancer screening tests is low among women in Appalachia Ohio. This finding illustrates the need for innovative interventions to improve rates of multiple cancer screening tests. PMID:26282630

  2. Development and Evaluation of a Magnetic Immunochromatographic Test To Detect Taenia solium, Which Causes Taeniasis and Neurocysticercosis in Humans▿

    PubMed Central

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N.; Dong, X. Fan; LaBorde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E.; Garcia, Hector H.; Gilman, Robert H.; Tsang, Victor C. W.; Wilkins, Patricia P.

    2010-01-01

    Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis. PMID:20181766

  3. Field determination of PCB in transformer oil. Volume 2. Clor-N-Oil PCB screening test. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, D.J.; Rouse, T.O.; Lynn, T.

    1984-10-01

    The requirements for handling and disposing of transformer minerals oils containing more than 50 ppM PCB are, by federal regulation, different from those for oils containing lower concentrations. A rapid and simple test to distinguish between samples containing more than or less than this concentration would simplify proper control of transformer oils. This report describes the development of a small disposable test kit that can be used on-site to screen the chlorine content of transformer oils. The kit consists of two soft plastic tubes in which thin walled glass ampules containing premeasured amounts of reagents are broken. The reaction sequencemore » in the kits converts the chlorine in PCB to chloride ion. The color of the liquid in the kit after the last step is blue to purple if the chloride content due to the initial chlorine concentration of the oil is less than 20 ppM. If the chlorine content of the oil is below 20 ppM, the PCB content must be below 50 ppM. The liquid is colorless if the chlorine content is greater than 20 ppM. In this latter case, it is necessary to determine by gas chromatography whether the PCB content is actually greater than 50 ppM or if there is some other source of chlorine in the oil.« less

  4. Clinical signs of early osteoarthritis: reproducibility and relation to x ray changes in 541 women in the general population.

    PubMed Central

    Hart, D J; Spector, T D; Brown, P; Wilson, P; Doyle, D V; Silman, A J

    1991-01-01

    The definition and classification of early clinically apparent osteoarthritis both in clinical situations and in epidemiological surveys remains a problem. Few data exist on the between-observer reproducibility of simple clinical methods of detecting hand and knee osteoarthritis in the population and their sensitivity and specificity as compared with radiography. Two observers first studied the reproducibility of a number of clinical signs in 41 middle aged women. Good rates of agreement were found for most of the clinical signs tested (kappa = 0.54-1.0). The more reproducible signs were then tested on a population of 541 women, aged 45-65, drawn from general practice, screening centres, and patients previously attending hospital for non-rheumatic problems. The major clinical signs used had a high specificity (87-99%) and lower sensitivity (20-49%) when compared with radiographs graded on the Kellgren and Lawrence scale (2+ = positive). When analysis was restricted to symptomatic radiographic osteoarthritis, levels of sensitivity were increased and specificity was lowered. These data show that certain physical signs of osteoarthritis are reproducible and may be used to identify clinical disease. They are not a substitute for radiographs, however, if radiographic change is regarded as the 'gold standard' of diagnosis. As the clinical signs tested seemed specific for osteoarthritis they may be of value in screening populations for clinical disease. PMID:1877852

  5. Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome

    PubMed Central

    Wald, Nicholas J.; Bestwick, Jonathan P.

    2013-01-01

    Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014

  6. The Dementia Services Mini-Screen: A Simple Method to Identify Patients and Caregivers Needing Enhanced Dementia Care Services

    PubMed Central

    Borson, Soo; Scanlan, James M.; Sadak, Tatiana; Lessig, Mary; Vitaliano, Peter

    2014-01-01

    Objective The National Alzheimer’s Plan calls for targeted health system change to improve outcomes for persons with dementia and their family caregivers. We explored whether dementia-specific service needs and gaps could be predicted from simple information that can be readily acquired in routine medical care settings. Method Primary family caregivers for cognitively impaired older adults (n=215) were asked about current stress, challenging patient behaviors, and prior-year needs and gaps in 16 medical and psychosocial services. Demographic data, caregiver stress, and patient clinical features were evaluated in regression analyses to identify unique predictors of service needs and gaps. Results Caregiver stress and patient behavior problems together accounted for an average of 24% of the whole-sample variance in total needs and gaps. Across all analyses, including total, medical, and psychosocial services needs and gaps, all other variables combined (comorbid chronic disease, dementia severity, age, caregiver relationship, and residence) accounted for an accounted for a mean of 3%, with no variable yielding more than 4% in any equation. We combined stress and behavior problem indicators into a simple screen. In early/mild dementia dyads (n=111) typical in primary care settings, the screen identified gaps in total and psychosocial care in 84% and 77%, respectively, of those with high stress/high behavior problems vs. 25% and 23%, respectively, of those with low stress/low behavior problems. Medical care gaps were dramatically higher in high stress/high behavior problem dyads (66%) than all others (12%). Conclusion A simple tool (likely completed in 1–2 minutes) which combines caregiver stress and patient behavior problems, the Dementia Services Mini-Screen, could help clinicians rapidly identify high need, high gap dyads. Health care systems could use it to estimate population needs for targeted dementia services and facilitate their development. PMID:24315560

  7. Mental transformations of spatial stimuli in humans and in monkeys: rotation vs. translocation.

    PubMed

    Nekovarova, Tereza; Nedvidek, Jan; Klement, Daniel; Rokyta, Richard; Bures, Jan

    2013-03-01

    We studied the ability of monkeys and humans to orient in one spatial frame ("response frame") according to abstract spatial stimuli presented in another spatial frame ("stimulus frame"). The stimuli were designed as simple maps of the "response space". We studied how the transformations of these stimuli affected the performance. The subjects were trained to choose a particular position in the response frame - either on a touch screen (monkeys) or on a keyboard (humans) - according to schematic spatial stimuli presented on the stimulus screen. The monkeys responded by touching one of four circles shown in corners of a rectangle displayed on the touch screen. The correct position was signaled by the stimulus ("map") presented on the stimulus screen. The map was a complementary rectangle, but only with one circle shown ("pointer"). The position of this circle indicated the correct position in the response frame. In the first experiment we only manipulated stimuli presented on the computer screen. The "map" was originally shown in the same position and orientation as the "response pattern" but later the position and the rotation of the map on the screen were changing. Such transformations of the stimuli allow us to study the mental operations that the animals performed and how particular mental transformations mutually differed. In the second experiment we tested whether the monkeys relied more on stimuli presented on the screen or on the surrounding stable environment and objects. We compared the performance of animals in tasks with rotated virtual maps in a stable surrounding environment with the performance in tasks where we rotated the surrounding frame (computer monitor), whereas the stimuli on the screen remained stable. In the third experiment we tested human subjects in analogous tests to compare the ability and cognitive strategies of monkeys and humans in this task. We showed that the mental strategies that monkeys used for orientation in one spatial frame according to the map presented in the other spatial frame depended on the type of stimulus manipulation. We demonstrated that for monkeys there was a difference between solving "mental rotation" and "mental translocation" in this experimental design. We showed that humans were able both to mentally rotate and translocate the displayed stimuli. However, the mental rotation was more difficult than mental translocation also for them. These experiments help us to understand how the monkeys perceive the abstract spatial information, create the representation of space and how they transform the information about the position obtained from one spatial frame into another. The comparison between humans and monkeys allows us to study this cognitive ability in phylogeny. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Serological diagnosis of brucellosis.

    PubMed

    Nielsen, K; Yu, W L

    2010-01-01

    To present a review and to describe the most widely used laboratory tests for serology diagnosis of brucellosis along with their pros and cons. Review the recent literature on brucellosis serology diagnostic tests. The choice of the testing strategy depends on the prevailing brucellosis epidemiological situation and the goal of testing. The 'gold standard' for the diagnosis of brucellosis is isolation and identification of the causative bacterium, a member of Brucella sp. Isolation of Brucella sp. requires high security laboratory facilities (biological containment level 3), highly skilled personnel, an extended turnaround time for results and it is considered a hazardous procedure. Hence brucellosis is generally diagnosed by detection of an elevated level of antibody in serum or other body fluid. This is a presumptive diagnosis as other microorganisms and perhaps environmental factors can also cause increased antibody levels. A large number of serological tests for brucellosis have been devised over the 100+ years since its initial isolation, starting with a simple agglutination test and progressing to sophisticated primary binding assays available today. However, no test devised to date is 100% accurate so generally serological diagnosis consists of testing sera by several tests, usually a screening test of high sensitivity, followed by a confirmatory test of high specificity.

  9. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  10. Testing and screening for chlamydia in general practice: a cross-sectional analysis.

    PubMed

    Thomson, Allison; Morgan, Simon; Henderson, Kim; Tapley, Amanda; Spike, Neil; Scott, John; van Driel, Mieke; Magin, Parker

    2014-12-01

    Chlamydia screening is widely advocated. General practice registrars are an important stage of clinical behaviour development. This study aimed to determine rates of, and factors associated with, registrars' chlamydia testing including asymptomatic screening. A cross-sectional analysis of data from Registrars Clinical Encounters in Training (ReCEnT), a cohort study of registrars' consultations. Registrars record details of 60 consecutive consultations in each GP-term of training. Outcome factors were chlamydia testing, asymptomatic screening and doctor-initiated screening. Testing occurred in 2.5% of 29,112 consultations (398 registrars) and in 5.8% of patients aged 15-25. Asymptomatic screening comprised 47.5% of chlamydia tests, and 55.6% of screening tests were doctor-initiated. Chlamydia testing was associated with female gender of doctor and patient, younger patient age, and patients new to doctor or practice. Asymptomatic screening was associated with practices where patients incur no fees, and in patients new to doctor or practice. Screening of female patients was more often doctor-initiated. GP registrars screen for chlamydia disproportionately in younger females and new patients. Our findings highlight potential opportunities to improve uptake of screening for chlamydia, including targeted education and training for registrars, campaigns targeting male patients, and addressing financial barriers to accessing screening services. © 2014 Public Health Association of Australia.

  11. The effect of presenting information about invasive follow-up testing on individuals' noninvasive colorectal cancer screening participation decision: results from a discrete choice experiment.

    PubMed

    Benning, Tim M; Dellaert, Benedict G C; Severens, Johan L; Dirksen, Carmen D

    2014-07-01

    Many national colorectal cancer screening campaigns have a similar structure. First, individuals are invited to take a noninvasive screening test, and, second, in the case of a positive screening test result, they are advised to undergo a more invasive follow-up test. The objective of this study was to investigate how much individuals' participation decision in noninvasive screening is affected by the presence or absence of detailed information about invasive follow-up testing and how this effect varies over screening tests. We used a labeled discrete choice experiment of three noninvasive colorectal cancer screening types with two versions that did or did not present respondents with detailed information about the possible invasive follow-up test (i.e., colonoscopy) and its procedure. We used data from 631 Dutch respondents aged 55 to 75 years. Each respondent received only one of the two versions (N = 310 for the invasive follow-up test information specification version, and N = 321 for the no-information specification version). Mixed logit model results show that detailed information about the invasive follow-up test negatively affects screening participation decisions. This effect can be explained mainly by a decrease in choice shares for the most preferred screening test (a combined stool and blood sample test). Choice share simulations based on the discrete choice experiment indicated that presenting invasive follow-up test information decreases screening participation by 4.79%. Detailed information about the invasive follow-up test has a negative effect on individuals' screening participation decisions in noninvasive colorectal cancer screening campaigns. This result poses new challenges for policymakers who aim not only to increase uptake but also to provide full disclosure to potential screening participants. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. Estimation of hypertension risk from lifestyle factors and health profile: a case study.

    PubMed

    Zheng, Zhuoyuan; Li, Ye; Cai, Yunpeng

    2014-01-01

    Hypertension is a highly prevalent risk factor for cardiovascular disease and it can also lead to other diseases which seriously harm the human health. Screening the risks and finding a clinical model for estimating the risk of onset, maintenance, or the prognosis of hypertension are of great importance to the prevention or treatment of the disease, especially if the indicator can be derived from simple health profile. In this study, we investigate a chronic disease questionnaire data set of 6563 rural citizens in East China and find out a clinical signature that can assess the risk of hypertension easily and accurately. The signature achieves an accuracy of about 83% on the external test dataset, with an AUC of 0.91. Our study demonstrates that a combination of simple lifestyle features can sufficiently reflect the risk of hypertension onset. This finding provides potential guidance for disease prevention and control as well as development of home care and home-care technologies.

  13. Printing-based fabrication method using sacrificial paper substrates for flexible and wearable microfluidic devices

    NASA Astrophysics Data System (ADS)

    Chung, Daehan; Gray, Bonnie L.

    2017-11-01

    We present a simple, fast, and inexpensive new printing-based fabrication process for flexible and wearable microfluidic channels and devices. Microfluidic devices are fabricated on textiles (fabric) for applications in clothing-based wearable microfluidic sensors and systems. The wearable and flexible microfluidic devices are comprised of water-insoluable screen-printable plastisol polymer. Sheets of paper are used as sacrificial substrates for multiple layers of polymer on the fabric’s surface. Microfluidic devices can be made within a short time using simple processes and inexpensive equipment that includes a laser cutter and a thermal laminator. The fabrication process is characterized to demonstrate control of microfluidic channel thickness and width. Film thickness smaller than 100 micrometers and lateral dimensions smaller than 150 micrometers are demonstrated. A flexible microfluidic mixer is also developed on fabric and successfully tested on both flat and curved surfaces at volumetric flow rates ranging from 5.5-46 ml min-1.

  14. Development and Psychometric Properties of the Standardized Assessment of Severity of Personality Disorder (SASPD).

    PubMed

    Olajide, Kike; Munjiza, Jasna; Moran, Paul; O'Connell, Lesley; Newton-Howes, Giles; Bassett, Paul; Akintomide, Gbolagade; Ng, Nicola; Tyrer, Peter; Mulder, Roger; Crawford, Mike J

    2018-02-01

    Personality disorder (PD) is increasingly categorized according to its severity, but there is no simple way to screen for severity according to ICD-11 criteria. We set out to develop the Standardized Assessment of Severity of Personality Disorder (SASPD). A total of 110 patients completed the SASPD together with a clinical assessment of the severity of personality disorder. We examined the predictive ability of the SASPD using the area under the ROC curve (AUC). Two to four weeks later, 43 patients repeated the SASPD to examine reliability. The SASPD had good predictive ability for determining mild (AUC = 0.86) and moderate (AUC = 0.84) PD at cut points of 8 and 10, respectively. Test-retest reliability of the SASPD was high (intraclass correlation coefficient = 0.93, 95% CI [0.88, 0.96]). The SASPD thus provides a simple, brief, and reliable indicator of the presence of mild or moderate PD according to ICD-11 criteria.

  15. Estimation of Hypertension Risk from Lifestyle Factors and Health Profile: A Case Study

    PubMed Central

    2014-01-01

    Hypertension is a highly prevalent risk factor for cardiovascular disease and it can also lead to other diseases which seriously harm the human health. Screening the risks and finding a clinical model for estimating the risk of onset, maintenance, or the prognosis of hypertension are of great importance to the prevention or treatment of the disease, especially if the indicator can be derived from simple health profile. In this study, we investigate a chronic disease questionnaire data set of 6563 rural citizens in East China and find out a clinical signature that can assess the risk of hypertension easily and accurately. The signature achieves an accuracy of about 83% on the external test dataset, with an AUC of 0.91. Our study demonstrates that a combination of simple lifestyle features can sufficiently reflect the risk of hypertension onset. This finding provides potential guidance for disease prevention and control as well as development of home care and home-care technologies. PMID:25019099

  16. Abnormal Cervical Cancer Screening Test Results

    MedlinePlus

    ... FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test results? • What is the difference between the terms cervical ...

  17. Cost-effectiveness of rapid syphilis screening in prenatal HIV testing programs in Haiti.

    PubMed

    Schackman, Bruce R; Neukermans, Christopher P; Fontain, Sandy N Nerette; Nolte, Claudine; Joseph, Patrice; Pape, Jean W; Fitzgerald, Daniel W

    2007-05-01

    New rapid syphilis tests permit simple and immediate diagnosis and treatment at a single clinic visit. We compared the cost-effectiveness, projected health outcomes, and annual cost of screening pregnant women using a rapid syphilis test as part of scaled-up prenatal testing to prevent mother-to-child HIV transmission in Haiti. A decision analytic model simulated health outcomes and costs separately for pregnant women in rural and urban areas. We compared syphilis syndromic surveillance (rural standard of care), rapid plasma reagin test with results and treatment at 1-wk follow-up (urban standard of care), and a new rapid test with immediate results and treatment. Test performance data were from a World Health Organization-Special Programme for Research and Training in Tropical Diseases field trial conducted at the GHESKIO Center Groupe Haitien d'Etude du Sarcome de Kaposi et des Infections Opportunistes in Port-au-Prince. Health outcomes were projected using historical data on prenatal syphilis treatment efficacy and included disability-adjusted life years (DALYs) of newborns, congenital syphilis cases, neonatal deaths, and stillbirths. Cost-effectiveness ratios are in US dollars/DALY from a societal perspective; annual costs are in US dollars from a payer perspective. Rapid testing with immediate treatment has a cost-effectiveness ratio of $6.83/DALY in rural settings and $9.95/DALY in urban settings. Results are sensitive to regional syphilis prevalence, rapid test sensitivity, and the return rate for follow-up visits. Integrating rapid syphilis testing into a scaled-up national HIV testing and prenatal care program would prevent 1,125 congenital syphilis cases and 1,223 stillbirths or neonatal deaths annually at a cost of $525,000. In Haiti, integrating a new rapid syphilis test into prenatal care and HIV testing would prevent congenital syphilis cases and stillbirths, and is cost-effective. A similar approach may be beneficial in other resource-poor countries that are scaling up prenatal HIV testing.

  18. Brief Report: Can Metrics of Reporting Bias Enhance Early Autism Screening Measures?

    ERIC Educational Resources Information Center

    Taylor, Cora M.; Vehorn, Alison; Noble, Hylan; Weitlauf, Amy S.; Warren, Zachary E.

    2014-01-01

    The goal of the current study was to develop and pilot the utility of two simple internal response bias metrics, over-reporting and under-reporting, in terms of additive clinical value within common screening practices for early detection of autism spectrum disorder risk. Participants were caregivers and children under 36 months of age (n = 145)…

  19. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Identification and Correction of Additive and Multiplicative Spatial Biases in Experimental High-Throughput Screening.

    PubMed

    Mazoure, Bogdan; Caraus, Iurie; Nadon, Robert; Makarenkov, Vladimir

    2018-06-01

    Data generated by high-throughput screening (HTS) technologies are prone to spatial bias. Traditionally, bias correction methods used in HTS assume either a simple additive or, more recently, a simple multiplicative spatial bias model. These models do not, however, always provide an accurate correction of measurements in wells located at the intersection of rows and columns affected by spatial bias. The measurements in these wells depend on the nature of interaction between the involved biases. Here, we propose two novel additive and two novel multiplicative spatial bias models accounting for different types of bias interactions. We describe a statistical procedure that allows for detecting and removing different types of additive and multiplicative spatial biases from multiwell plates. We show how this procedure can be applied by analyzing data generated by the four HTS technologies (homogeneous, microorganism, cell-based, and gene expression HTS), the three high-content screening (HCS) technologies (area, intensity, and cell-count HCS), and the only small-molecule microarray technology available in the ChemBank small-molecule screening database. The proposed methods are included in the AssayCorrector program, implemented in R, and available on CRAN.

  1. Recommendations for a step‐wise comparative approach to the evaluation of new screening tests for colorectal cancer

    PubMed Central

    Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.

    2016-01-01

    BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588

  2. Recommendations for a step-wise comparative approach to the evaluation of new screening tests for colorectal cancer.

    PubMed

    Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J

    2016-03-15

    New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.

  3. A large population-based randomized controlled trial to increase attendance at screening for cervical cancer.

    PubMed

    Eaker, Sonja; Adami, Hans-Olov; Granath, Fredrik; Wilander, Erik; Sparén, Pär

    2004-03-01

    Although cervical cancer is one of the potentially most preventable malignancies, it is still fairly common. In settings with established screening programs, increased compliance is important for future reduction in cervical cancer incidence, but it is presently unclear how this can be effectively achieved. We conducted a randomized controlled trial including all 12,240 women invited to organized screening in Sweden. To increase compliance, three successive interventions were tested: (a) modified invitation versus the standard invitation letter, (b) reminder letter to nonattenders after the first intervention versus no reminder letter, and (c) phone reminder to nonattenders after the reminder letter versus no phone reminder. We analyzed the proportion of women attending screening after each intervention and the cumulative proportion after the interventions as well as the cumulative proportions of cytologic abnormalities. The modified invitation did not increase attendance compared with the standard invitation letter [difference 1.3% 95% confidence interval (CI) -0.3 to 2.9]. In contrast, a reminder letter increased the proportion of women attending with 9.2% (95% CI 7.9-10.5) compared with women who did not receive a reminder letter, and a phone reminder increased the proportion of women attending with 31.4% (95% CI 26.9-35.9). Combinations of modified invitation, written reminder, and phone reminder almost doubled attendance within 12 months, and the number of detected cytologic abnormalities was more than tripled. Simple reminders by mail and phone can drastically increase women's participation in Papanicolaou smear screening and increase the number of detected precursor lesions and thereby save lives.

  4. Nanoliter microfluidic hybrid method for simultaneous screening and optimization validated with crystallization of membrane proteins

    PubMed Central

    Li, Liang; Mustafi, Debarshi; Fu, Qiang; Tereshko, Valentina; Chen, Delai L.; Tice, Joshua D.; Ismagilov, Rustem F.

    2006-01-01

    High-throughput screening and optimization experiments are critical to a number of fields, including chemistry and structural and molecular biology. The separation of these two steps may introduce false negatives and a time delay between initial screening and subsequent optimization. Although a hybrid method combining both steps may address these problems, miniaturization is required to minimize sample consumption. This article reports a “hybrid” droplet-based microfluidic approach that combines the steps of screening and optimization into one simple experiment and uses nanoliter-sized plugs to minimize sample consumption. Many distinct reagents were sequentially introduced as ≈140-nl plugs into a microfluidic device and combined with a substrate and a diluting buffer. Tests were conducted in ≈10-nl plugs containing different concentrations of a reagent. Methods were developed to form plugs of controlled concentrations, index concentrations, and incubate thousands of plugs inexpensively and without evaporation. To validate the hybrid method and demonstrate its applicability to challenging problems, crystallization of model membrane proteins and handling of solutions of detergents and viscous precipitants were demonstrated. By using 10 μl of protein solution, ≈1,300 crystallization trials were set up within 20 min by one researcher. This method was compatible with growth, manipulation, and extraction of high-quality crystals of membrane proteins, demonstrated by obtaining high-resolution diffraction images and solving a crystal structure. This robust method requires inexpensive equipment and supplies, should be especially suitable for use in individual laboratories, and could find applications in a number of areas that require chemical, biochemical, and biological screening and optimization. PMID:17159147

  5. A fluorescent immunochromatographic strip test using a quantum dot-antibody probe for rapid and quantitative detection of 1-aminohydantoin in edible animal tissues.

    PubMed

    Le, Tao; Zhang, Zhihao; Wu, Juan; Shi, Haixing; Cao, Xudong

    2018-01-01

    A rapid, simple, and sensitive fluorescent immunochromatographic strip test (ICST) based on quantum dots (QDs) has been developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. To achieve this, QD-labeled antibody conjugates, which consist of CdSe/ZnS QDs and monoclonal antibodies, were prepared by an activated ester method. Under optimal conditions, with the nitrophenyl derivative of AHD as the target, the ICST had a linear range from 0.1 to 100 ng/mL, with a correlation coefficient of 0.9656 and a 50% inhibitory concentration of 4.51 ng/mL. The limit of detection was 0.14 ng/g, which was below the minimum required performance limit of 1 μg/kg for AHD established by the European Commission. The recoveries for AHD ranged from 81.5% to 108.2%, with coefficients of variation below 13%, based on intraday and interday analysis. Furthermore, for AHD in real samples, the ICST showed high reliability and high correlation with liquid chromatography-tandem mass spectrometry (correlation coefficient of 0.9916). To the best of our knowledge, this is the first report of a novel and sensitive method based on a fluorescent ICST to detect AHD below the minimum required performance limit. The ICST demonstrated high reliability, and could be ideally suited for rapid, simple, and on-site screening of AHD contamination in animal tissues. Graphical abstract A rapid, simple, and sensitive fluorescent immunochromatographic strip test that is based on quantum dots was developed to detect 1-aminohydantoin (AHD), a major metabolite of nitrofurantoin in animal tissues. 2-NBA 2-nitrobenzaldehyde, NP nitrophenyl.

  6. Direct Identification of On-Bead Peptides Using Surface-Enhanced Raman Spectroscopic Barcoding System for High-Throughput Bioanalysis

    PubMed Central

    Kang, Homan; Jeong, Sinyoung; Koh, Yul; Geun Cha, Myeong; Yang, Jin-Kyoung; Kyeong, San; Kim, Jaehi; Kwak, Seon-Yeong; Chang, Hye-Jin; Lee, Hyunmi; Jeong, Cheolhwan; Kim, Jong-Ho; Jun, Bong-Hyun; Kim, Yong-Kweon; Hong Jeong, Dae; Lee, Yoon-Sik

    2015-01-01

    Recently, preparation and screening of compound libraries remain one of the most challenging tasks in drug discovery, biomarker detection, and biomolecular profiling processes. So far, several distinct encoding/decoding methods such as chemical encoding, graphical encoding, and optical encoding have been reported to identify those libraries. In this paper, a simple and efficient surface-enhanced Raman spectroscopic (SERS) barcoding method using highly sensitive SERS nanoparticles (SERS ID) is presented. The 44 kinds of SERS IDs were able to generate simple codes and could possibly generate more than one million kinds of codes by incorporating combinations of different SERS IDs. The barcoding method exhibited high stability and reliability under bioassay conditions. The SERS ID encoding based screening platform can identify the peptide ligand on the bead and also quantify its binding affinity for specific protein. We believe that our SERS barcoding technology is a promising method in the screening of one-bead-one-compound (OBOC) libraries for drug discovery. PMID:26017924

  7. Direct identification of on-bead peptides using surface-enhanced Raman spectroscopic barcoding system for high-throughput bioanalysis.

    PubMed

    Kang, Homan; Jeong, Sinyoung; Koh, Yul; Geun Cha, Myeong; Yang, Jin-Kyoung; Kyeong, San; Kim, Jaehi; Kwak, Seon-Yeong; Chang, Hye-Jin; Lee, Hyunmi; Jeong, Cheolhwan; Kim, Jong-Ho; Jun, Bong-Hyun; Kim, Yong-Kweon; Hong Jeong, Dae; Lee, Yoon-Sik

    2015-05-28

    Recently, preparation and screening of compound libraries remain one of the most challenging tasks in drug discovery, biomarker detection, and biomolecular profiling processes. So far, several distinct encoding/decoding methods such as chemical encoding, graphical encoding, and optical encoding have been reported to identify those libraries. In this paper, a simple and efficient surface-enhanced Raman spectroscopic (SERS) barcoding method using highly sensitive SERS nanoparticles (SERS ID) is presented. The 44 kinds of SERS IDs were able to generate simple codes and could possibly generate more than one million kinds of codes by incorporating combinations of different SERS IDs. The barcoding method exhibited high stability and reliability under bioassay conditions. The SERS ID encoding based screening platform can identify the peptide ligand on the bead and also quantify its binding affinity for specific protein. We believe that our SERS barcoding technology is a promising method in the screening of one-bead-one-compound (OBOC) libraries for drug discovery.

  8. Acceptance testing and commissioning of Kodak Directview CR-850 digital radiography system.

    PubMed

    Bezak, E; Nelligan, R A

    2006-03-01

    This Technical Paper describes Acceptance Testing and Commissioning of the Kodak DirectView CR-850 digital radiography system installed at the Royal Adelaide Hospital. The first of its type installed in Australia, the system is a "dry" image processor, for which no chemicals are required to develop images. Rather, latent radiographic images are stored on photostimulable phosphor screens, which are scanned and displayed by a reader unit. The image can be digitally processed and enhanced before it is forwarded to a storage device, printer or workstation display, thereby alleviating the need to re-expose patients to achieve satisfactory quality images. The phosphor screens are automatically erased, ready for re-use. Results are reported of tests carried out using the optional "Total Quality Tool" quality assurance package installed with the system. This package includes analysis and reporting software which provides for simple testing and reporting of many important characteristics of the system, such as field uniformity, aspect ratio, line and pixel positions, image and system noise, exposure response, scan linearity, modulation transfer function (MTF) and image artefacts. Acceptance Tests were performed for kV and MV exposures. Resolution for MV exposures was at least 0.8 l/mm, and measured phantom dimensions were within 1.05% of expected magnification. Reproducibility between cassettes was within 1.6%. The mean pixel values on the central axis were close to linear for MV exposures from 3 to 10 MU and reached saturation level at around 20 MU for 6 MV and around 30 MV for 23 MV beams. Noise levels were below 0.2 %.

  9. Unexplained lower abdominal pain associated with sacroiliac joint dysfunction: report of 2 cases.

    PubMed

    Morimoto, Daijiro; Isu, Toyohiko; Kim, Kyongsong; Matsumoto, Ryoji; Isobe, Masanori

    2011-01-01

    A 25-year-old woman and a 31-year-old man presented with chronic lower back pain and unexplained lower abdominal pain. Both patients had groin tenderness at the medial border of the anterior superior iliac spine. The results of radiographical and physical examinations suggested sacroiliac joint dysfunction. Sacroiliac joint injection relieved their symptoms, including groin tenderness. In our experience, groin tenderness is highly specific for sacroiliac joint dysfunction. We speculate that spasm of the iliac muscle can cause groin pain and tenderness. Groin pain and a history of unexplained abdominal pain, with lower back pain, are symptoms that suggest sacroiliac joint dysfunction. Additionally, compression of the iliac muscle is a simple and useful maneuver; therefore, it can be used as a screening test for sacroiliac joint dysfunction, alongside other provocation tests.

  10. Toxoplasmosis serology: an efficient hemagglutination procedure to detect IgG and IgM antibodies.

    PubMed

    Camargo, M E; Moura, M E; Leser, P G

    1989-01-01

    In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo, an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A--rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

  11. Border screening vs. community level disease control for infectious diseases: Timing and effectiveness

    NASA Astrophysics Data System (ADS)

    Kim, Sehjeong; Chang, Dong Eui

    2017-06-01

    There have been many studies of the border screening using a simple math model or a statistical analysis to investigate the ineffectiveness of border screening during 2003 and 2009 pandemics. However, the use of border screening is still a controversial issue. It is due to focusing only on the functionality of border screening without considering the timing to use. In this paper, we attempt to qualitatively answer whether the use of border screening is a desirable action during a disease pandemic. Thus, a novel mathematical model with a transition probability of status change during flight and border screening is developed. A condition to check a timing of the border screening is established in terms of a lower bound of the basic reproduction number. If the lower bound is greater than one, which indicates a pandemic, then the border screening may not be effective and the disease persists. In this case, a community level control strategy should be conducted.

  12. A simple and sensitive method to measure timing accuracy.

    PubMed

    De Clercq, Armand; Crombez, Geert; Buysse, Ann; Roeyers, Herbert

    2003-02-01

    Timing accuracy in presenting experimental stimuli (visual information on a PC or on a TV) and responding (keyboard presses and mouse signals) is of importance in several experimental paradigms. In this article, a simple system for measuring timing accuracy is described. The system uses two PCs (at least Pentium II, 200 MHz), a photocell, and an amplifier. No additional boards and timing hardware are needed. The first PC, a SlavePC, monitors the keyboard presses or mouse signals from the PC under test and uses a photocell that is placed in front of the screen to detect the appearance of visual stimuli on the display. The software consists of a small program running on the SlavePC. The SlavePC is connected through a serial line with a second PC. This MasterPC controls the SlavePC through an ActiveX control, which is used in a Visual Basic program. The accuracy of our system was investigated by using a similar setup of a SlavePC and a MasterPC to generate pulses and by using a pulse generator card. These tests revealed that our system has a 0.01-msec accuracy. As an illustration, the reaction time accuracy of INQUISIT for a few applications was tested using our system. It was found that in those applications that we investigated, INQUISIT measures reaction times from keyboard presses with millisecond accuracy.

  13. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  14. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  15. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  16. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  17. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  18. Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.

    PubMed

    Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L

    2010-06-01

    To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.

  19. Syndromic Algorithms for Detection of Gambiense Human African Trypanosomiasis in South Sudan

    PubMed Central

    Palmer, Jennifer J.; Surur, Elizeous I.; Goch, Garang W.; Mayen, Mangar A.; Lindner, Andreas K.; Pittet, Anne; Kasparian, Serena; Checchi, Francesco; Whitty, Christopher J. M.

    2013-01-01

    Background Active screening by mobile teams is considered the best method for detecting human African trypanosomiasis (HAT) caused by Trypanosoma brucei gambiense but the current funding context in many post-conflict countries limits this approach. As an alternative, non-specialist health care workers (HCWs) in peripheral health facilities could be trained to identify potential cases who need testing based on their symptoms. We explored the predictive value of syndromic referral algorithms to identify symptomatic cases of HAT among a treatment-seeking population in Nimule, South Sudan. Methodology/Principal Findings Symptom data from 462 patients (27 cases) presenting for a HAT test via passive screening over a 7 month period were collected to construct and evaluate over 14,000 four item syndromic algorithms considered simple enough to be used by peripheral HCWs. For comparison, algorithms developed in other settings were also tested on our data, and a panel of expert HAT clinicians were asked to make referral decisions based on the symptom dataset. The best performing algorithms consisted of three core symptoms (sleep problems, neurological problems and weight loss), with or without a history of oedema, cervical adenopathy or proximity to livestock. They had a sensitivity of 88.9–92.6%, a negative predictive value of up to 98.8% and a positive predictive value in this context of 8.4–8.7%. In terms of sensitivity, these out-performed more complex algorithms identified in other studies, as well as the expert panel. The best-performing algorithm is predicted to identify about 9/10 treatment-seeking HAT cases, though only 1/10 patients referred would test positive. Conclusions/Significance In the absence of regular active screening, improving referrals of HAT patients through other means is essential. Systematic use of syndromic algorithms by peripheral HCWs has the potential to increase case detection and would increase their participation in HAT programmes. The algorithms proposed here, though promising, should be validated elsewhere. PMID:23350005

  20. Pyrazinamidase, CR-MOX agar, salicin fermentation-esculin hydrolysis, and D-xylose fermentation for identifying pathogenic serotypes of Yersinia enterocolitica.

    PubMed Central

    Farmer, J J; Carter, G P; Miller, V L; Falkow, S; Wachsmuth, I K

    1992-01-01

    We evaluated several simple laboratory tests that have been used to identify pathogenic serotypes of Yersinia enterocolitica or to indicate the pathogenic potential of individual strains. A total of 100 strains of Y. enterocolitica were studied, including 25 isolated during five outbreak investigations, 63 from sporadic cases, and 12 from stock cultures. The pyrazinamidase test, which does not depend on the Yersinia virulence plasmid, correctly identified 60 of 63 (95% sensitivity) strains of pathogenic serotypes and 34 of 37 (92% specificity) strains of nonpathogenic serotypes. Salicin fermentation-esculin hydrolysis (25 degrees C, 48 h) correctly identified all 63 (100% sensitivity) strains of the pathogenic serotypes and 34 of 37 (92% specificity) strains of the nonpathogenic serotypes. The results of the pyrazinamidase and salicin-esculin tests disagreed for only 7 of the 100 strains of Y. enterocolitica, and these would require additional testing. Congo red-magnesium oxalate (CR-MOX) agar determines Congo red dye uptake and calcium-dependent growth at 36 degrees C, and small red colonies are present only if the strain contains the Yersinia virulence plasmid. This test has proven to be extremely useful for freshly isolated cultures, but only 15 of 62 strains of pathogenic serotypes that had been stored for 1 to 10 years were CR-MOX positive. None of the 16 strains of Y. enterocolitica serotype O3 fermented D-xylose, so this test easily differentiated strains of this serotype, which now appears to be the most common in the United States. Although antisera that can actually be used to serotype strains of Y. enterocolitica are not readily available, the four simple tests described above can be used to screen for pathogenic serotypes. Images PMID:1400958

Top