Ebeid, Walid M; Elkady, Ehab F; El-Zaher, Asmaa A; El-Bagary, Ramzia I; Patonay, Gabor
2014-01-01
The recently approved angiotensin II receptor blocker, azilsartan medoxomil (AZL), was determined spectrophotometrically and spectrofluorimetrically in its combination with chlorthalidone (CLT) in their combined dosage form. The UV-spectrophotometric technique depends on simultaneous measurement of the first derivative spectra for AZL and CLT at 286 and 257 nm, respectively, in methanol. The spectrofluorimetric technique depends on measurement of the fourth derivative of the synchronous spectra intensities of AZL in presence of CLT at 298 nm in methanol. The effects of different solvents on spectrophotometric and spectrofluorimetric responses were studied. For, the spectrofluorimetric study, the effect of pH and micelle-assisted fluorescence enhancement were also studied. Linearity, accuracy, and precision were found to be satisfactory over the concentration ranges of 8–50 μg mL−1 and 2–20 μg mL−1 for AZL and CLT, respectively, in the spectrophotometric method as well as 0.01–0.08 μg mL−1 for AZL in the spectrofluorimetric method. The methods were successfully applied for the determination of the studied drugs in their co-formulated tablets. The developed methods are inexpensive and simple for the quality control and routine analysis of the cited drugs in bulk and in pharmaceuticals. PMID:24855334
NASA Astrophysics Data System (ADS)
Omar, Mahmoud A.; Derayea, Sayed M.; Abdel-Lateef, Mohamed A.; El Hamd, Mohamed A.
2018-02-01
Two simple, selective and accurate methods were developed for the determination of Labetalol hydrochloride in pure form and pharmaceutical tablets. Both methods are based on derivatization of the studied drug with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBDsbnd Cl) in alkaline medium (pH 7.5).The reaction product was measured spectrofluorimetrically at 540 nm after excitation at 476 nm (method I) or spectrophotometrically at 480 nm (method II). The calibration graphs were rectilinear over the concentration ranges of 0.10-2.0 and 1.0-11.0 μg mL- 1 for methods I and II, respectively. The proposed methods were successfully applied to the analysis of commercial tablets without interference from common excipients. Furthermore, the spectrofluorimetric method was utilized for the in vitro determination of labetalol in spiked human plasma, with a percent mean recovery (n = 3) of 97.80 ± 1.29%. Moreover, the spectrofluorimetric method was extended to examine the stability study of LBT under different stress conditions such as alkaline, acidic, oxidative, photolytic and a thermal degradation.
Omar, Mahmoud A; Derayea, Sayed M; Abdel-Lateef, Mohamed A; El Hamd, Mohamed A
2018-02-05
Two simple, selective and accurate methods were developed for the determination of Labetalol hydrochloride in pure form and pharmaceutical tablets. Both methods are based on derivatization of the studied drug with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBDCl) in alkaline medium (pH7.5).The reaction product was measured spectrofluorimetrically at 540nm after excitation at 476nm (method I) or spectrophotometrically at 480nm (method II). The calibration graphs were rectilinear over the concentration ranges of 0.10-2.0 and 1.0-11.0μgmL -1 for methods I and II, respectively. The proposed methods were successfully applied to the analysis of commercial tablets without interference from common excipients. Furthermore, the spectrofluorimetric method was utilized for the in vitro determination of labetalol in spiked human plasma, with a percent mean recovery (n=3) of 97.80±1.29%. Moreover, the spectrofluorimetric method was extended to examine the stability study of LBT under different stress conditions such as alkaline, acidic, oxidative, photolytic and a thermal degradation. Copyright © 2017 Elsevier B.V. All rights reserved.
Kara, Derya; Fisher, Andrew; Foulkes, Mike; Hill, Steve J
2010-01-01
A simple, easy to use and selective spectrofluorimetric method for the determination of trace levels of gallium has been developed. A new Schiff base, N-o-vanillidine-2-amino-p-cresol (OVAC) was synthesized and its fluorescence activity with gallium investigated. Based on this chelation reaction, a spectrofluorimetric method has been developed for the determination of gallium in synthetically prepared Ga-U and Ga-As samples buffered at pH 4.0 using acetic acid-sodium acetate. The chelation reaction between Ga(III) and N-o-vanillidine-2-amino-p-cresol was very fast, requiring only 30min at room temperature to complex completely. The limit of detection (LOD) (3sigma) for Ga(III) was 7.17 nM (0.50 microgL(-1)), determined from the analysis of 11 different solutions of 20 microg L(-1) Ga(III). Copyright 2009 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Abdellatef, Hisham E.; El-Henawee, Magda M.; El-Sayed, Heba M.; Ayad, Magda M.
2006-12-01
Sensitive spectrophotometric and spectrofluorimetric methods are described for the determination of tramadol, acebutolol and dothiepin (dosulepin) hydrochlorides. The two methods are based on the condensation of the cited drugs with the mixed anhydrides of malonic and acetic acids at 60 °C for 25-40 min. The coloured condensation products are suitable for the spectrophotometric and spectrofluorimetric determination at 329-333 and 431-434 nm (excitation at 389 nm), respectively. For the spectrophotometric method, Beer's law was obeyed from 0.5 to 2.5 μg ml -1 for tramadol, dothiepin and 5-25 μg ml -1 for acebutolol. Using the spectrofluorimetric method linearity ranged from 0.25 to 1.25 μg ml -1 for tramadol, dothiepin and 1-5 μg ml -1 for acebutolol. Mean percentage recoveries for the spectrophotometric method were 99.68 ± 1.00, 99.95 ± 1.11 and 99.72 ± 1.01 for tramadol, acebutolol and dothiepin, respectively and for the spectrofluorimetric method, recoveries were 99.5 ± 0.844, 100.32 ± 0.969 and 99.82 ± 1.15 for the three drugs, respectively. The optimum experimental parameters for the reaction has been studied. The validity of the described procedures was assessed. Statistical analysis of the results has been carried out revealing high accuracy and good precision. The proposed methods were successfully applied for the determination of the selected drugs in their pharmaceutical preparations with good recoveries. The procedures were accurate, simple and suitable for quality control application.
El-Didamony, Akram M; Ali, Ismail I
2013-01-01
We describe the first studies of a simple and sensitive spectrofluorimetric and spectrophotometric methods for the analysis of nalbuphine (NLB) in dosage form and biological fluids. The spectrofluorimetric method was based on the oxidation of NLB with Ce(IV) to produce Ce(III) and its fluorescence was monitored at 352 nm after excitation at 250 nm. The spectrophotometric method involves addition of a known excess of Ce(IV) to NLB in acid medium, followed by determination of residual Ce(IV) by reacting with a fixed amount of methyl orange and measuring absorbance at 510 nm. In both methods, the amount of Ce(IV) reacted corresponds to the amount of NLB and measured fluorescence or absorbance were found to increase linearly with the concentration of NLB, which are corroborated by correlation coefficients of 0.9997 and 0.9999 for spectrofluorimetric and spectrophotometric methods, respectively. Different variables affecting the reaction conditions such as concentrations of Ce(IV), type and concentration of acid medium, reaction time, temperature, and diluting solvents were carefully studied and optimized. The accuracy and precision of the methods were evaluated on intra-day and inter-day basis. The proposed methods were successfully applied for the determination of NLB in pharmaceutical formulation and biological samples with good recoveries. Copyright © 2012 John Wiley & Sons, Ltd.
Abdel-Aziz, Omar; Ayad, Miriam F; Tadros, Mariam M
2015-04-05
Simple, selective and reproducible spectrofluorimetric and spectrophotometric methods have been developed for the determination of vildagliptin and saxagliptin in bulk and their pharmaceutical dosage forms. The first proposed spectrofluorimetric method is based on the dansylation reaction of the amino group of vildagliptin with dansyl chloride to form a highly fluorescent product. The formed product was measured spectrofluorimetrically at 455 nm after excitation at 345 nm. Beer's law was obeyed in a concentration range of 100-600 μg ml(-1). The second proposed spectrophotometric method is based on the charge transfer complex of saxagliptin with tetrachloro-1,4-benzoquinone (p-chloranil). The formed charge transfer complex was measured spectrophotometrically at 530 nm. Beer's law was obeyed in a concentration range of 100-850 μg ml(-1). The third proposed spectrophotometric method is based on the condensation reaction of the primary amino group of saxagliptin with formaldehyde and acetyl acetone to form a yellow colored product known as Hantzsch reaction, measured at 342.5 nm. Beer's law was obeyed in a concentration range of 50-300 μg ml(-1). All the variables were studied to optimize the reactions' conditions using factorial design. The developed methods were validated and proved to be specific and accurate for quality control of vildagliptin and saxagliptin in their pharmaceutical dosage forms. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.
2015-04-01
Simple, selective and reproducible spectrofluorimetric and spectrophotometric methods have been developed for the determination of vildagliptin and saxagliptin in bulk and their pharmaceutical dosage forms. The first proposed spectrofluorimetric method is based on the dansylation reaction of the amino group of vildagliptin with dansyl chloride to form a highly fluorescent product. The formed product was measured spectrofluorimetrically at 455 nm after excitation at 345 nm. Beer's law was obeyed in a concentration range of 100-600 μg ml-1. The second proposed spectrophotometric method is based on the charge transfer complex of saxagliptin with tetrachloro-1,4-benzoquinone (p-chloranil). The formed charge transfer complex was measured spectrophotometrically at 530 nm. Beer's law was obeyed in a concentration range of 100-850 μg ml-1. The third proposed spectrophotometric method is based on the condensation reaction of the primary amino group of saxagliptin with formaldehyde and acetyl acetone to form a yellow colored product known as Hantzsch reaction, measured at 342.5 nm. Beer's law was obeyed in a concentration range of 50-300 μg ml-1. All the variables were studied to optimize the reactions' conditions using factorial design. The developed methods were validated and proved to be specific and accurate for quality control of vildagliptin and saxagliptin in their pharmaceutical dosage forms.
El-Bagary, Ramzia I; Elkady, Ehab F; Farid, Naira A; Youssef, Nadia F
2017-03-05
Apixaban and Tirofiban Hydrochloride are low molecular weight anticoagulants. The two drugs exhibit native fluorescence that allow the development of simple and valid spectrofluorimetric methods for the determination of Apixaban at λ ex/λ em=284/450nm and tirofiban HCl at λ ex/λ em=227/300nm in aqueous media. Different experimental parameters affecting fluorescence intensities were carefully studied and optimized. The fluorescence intensity-concentration plots were linear over the ranges of 0.2-6μgml -1 for apixaban and 0.2-5μgml -1 for tirofiban HCl. The limits of detection were 0.017 and 0.019μgml -1 and quantification limits were 0.057 and 0.066μgml -1 for apixaban and tirofiban HCl, respectively. The fluorescence quantum yield of apixaban and tirofiban were calculated with values of 0.43 and 0.49. Method validation was evaluated for linearity, specificity, accuracy, precision and robustness as per ICH guidelines. The proposed spectrofluorimetric methods were successfully applied for the determination of apixaban in Eliquis tablets and tirofiban HCl in Aggrastat intravenous infusion. Tolerance ratio was tested to study the effect of foreign interferences from dosage forms excipients. Using Student's t and F tests, revealed no statistically difference between the developed spectrofluorimetric methods and the comparison methods regarding the accuracy and precision, so can be contributed to the analysis of apixaban and tirofiban HCl in QC laboratories as an alternative method. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Omar, Mahmoud A.; Badr El-Din, Kalid M.; Salem, Hesham; Abdelmageed, Osama H.
2018-03-01
Two simple and sensitive spectrophotometric and spectrofluorimetric methods for the determination of terbutaline sulfate, fenoterol hydrobromide, etilefrine hydrochloride, isoxsuprine hydrochloride, ethamsylate, doxycycline hyclate have been developed. Both methods were based on the oxidation of the cited drugs with cerium (IV) in acid medium. The spectrophotometric method was based on measurement of the absorbance difference (ΔA), which represents the excess cerium (IV), at 317 nm for each drug. On the other hand, the spectrofluorimetric method was based on measurement of the fluorescent of the produced cerium (III) at emission wavelength 354 nm (λexcitation = 255 nm) for the concentrations studied for each drug. For both methods, the variables affecting the reactions were carefully investigated and the conditions were optimized. Linear relationships were found between either ΔA or the fluorescent of the produced cerium (III) values and the concentration of the studied drugs in a general concentration range of 2.0-24.0 μg mL- 1, 20.0-24.0 ng mL- 1 with good correlation coefficients in the following range 0.9990-0.9999, 0.9990-0.9993 for spectrophotometric and spectrofluorimetric methods respectively. The limits of detection and quantitation of spectrophotometric method were found in general concentration range 0.190-0.787 and 0.634-2.624 μg mL- 1respectively. For spectrofluorimetric method, the limits of detection and quantitation were found in general concentration range 4.77-9.52 and 15.91-31.74 ng mL- 1 respectively. The stoichiometry of the reaction was determined, and the reactions pathways were postulated. The analytical performance of the methods, in terms of accuracy and precision, were statistically validated and the results obtained were satisfactory. The methods have been successfully applied to the determination of the cited drugs in their commercial pharmaceutical formulations. Statistical comparison of the results with the reference methods showed excellent agreement and proved that no significant difference in the accuracy and precision.
Hammad, Mohamed A; Omar, Mahmoud A; Salman, Baher I
2017-09-01
A highly sensitive, cheap, simple and accurate spectrofluorimetric method has been developed and validated for the determination of alfuzosin hydrochloride and terazosin hydrochloride in their pharmaceutical dosage forms and in human plasma. The developed method is based on the reaction of the primary amine moiety in the studied drugs with acetylacetone and formaldehyde according to the Hantzsch reaction, producing yellow fluorescent products that can be measured spectrofluorimetrically at 480 nm after excitation at 415 nm. Different experimental parameters affecting the development and stability of the reaction products were carefully studied and optimized. The fluorescence-concentration plots of alfuzosin and terazosin were rectilinear over a concentration range of 70-900 ng ml -1 , with quantitation limits 27.1 and 32.2 ng ml -1 for alfuzosin and terazosin, respectively. The proposed method was validated according to ICH guidelines and successfully applied to the analysis of the investigated drugs in dosage forms, content uniformity test and spiked human plasma with high accuracy. Copyright © 2017 John Wiley & Sons, Ltd.
Ibrahim, F; Wahba, M E K; Magdy, G
2018-01-05
In this study, three novel, sensitive, simple and validated spectrophotometric and spectrofluorimetric methods have been proposed for estimation of some important antimicrobial drugs. The first two methods have been proposed for estimation of two important third-generation cephalosporin antibiotics namely, cefixime and cefdinir. Both methods were based on condensation of the primary amino group of the studied drugs with acetyl acetone and formaldehyde in acidic medium. The resulting products were measured by spectrophotometric (Method I) and spectrofluorimetric (Method II) tools. Regarding method I, the absorbance was measured at 315nm and 403nm with linearity ranges of 5.0-140.0 and 10.0-100.0μg/mL for cefixime and cefdinir, respectively. Meanwhile in method II, the produced fluorophore was measured at λ em 488nm or 491nm after excitation at λ ex 410nm with linearity ranges of 0.20-10.0 and 0.20-36.0μg/mL for cefixime and cefdinir, respectively. On the other hand, method III was devoted to estimate nifuroxazide spectrofluorimetrically depending on formation of highly fluorescent product upon reduction of the studied drug with Zinc powder in acidic medium. Measurement of the fluorescent product was carried out at λ em 335nm following excitation at λ ex 255nm with linearity range of 0.05 to 1.6μg/mL. The developed methods were subjected to detailed validation procedure, moreover they were used for the estimation of the concerned drugs in their pharmaceuticals. It was found that there is a good agreement between the obtained results and those obtained by the reported methods. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ibrahim, F.; Wahba, M. E. K.; Magdy, G.
2018-01-01
In this study, three novel, sensitive, simple and validated spectrophotometric and spectrofluorimetric methods have been proposed for estimation of some important antimicrobial drugs. The first two methods have been proposed for estimation of two important third-generation cephalosporin antibiotics namely, cefixime and cefdinir. Both methods were based on condensation of the primary amino group of the studied drugs with acetyl acetone and formaldehyde in acidic medium. The resulting products were measured by spectrophotometric (Method I) and spectrofluorimetric (Method II) tools. Regarding method I, the absorbance was measured at 315 nm and 403 nm with linearity ranges of 5.0-140.0 and 10.0-100.0 μg/mL for cefixime and cefdinir, respectively. Meanwhile in method II, the produced fluorophore was measured at λem 488 nm or 491 nm after excitation at λex 410 nm with linearity ranges of 0.20-10.0 and 0.20-36.0 μg/mL for cefixime and cefdinir, respectively. On the other hand, method III was devoted to estimate nifuroxazide spectrofluorimetrically depending on formation of highly fluorescent product upon reduction of the studied drug with Zinc powder in acidic medium. Measurement of the fluorescent product was carried out at λem 335 nm following excitation at λex 255 nm with linearity range of 0.05 to 1.6 μg/mL. The developed methods were subjected to detailed validation procedure, moreover they were used for the estimation of the concerned drugs in their pharmaceuticals. It was found that there is a good agreement between the obtained results and those obtained by the reported methods.
Omar, Mahmoud A; Badr El-Din, Kalid M; Salem, Hesham; Abdelmageed, Osama H
2018-03-05
Two simple and sensitive spectrophotometric and spectrofluorimetric methods for the determination of terbutaline sulfate, fenoterol hydrobromide, etilefrine hydrochloride, isoxsuprine hydrochloride, ethamsylate, doxycycline hyclate have been developed. Both methods were based on the oxidation of the cited drugs with cerium (IV) in acid medium. The spectrophotometric method was based on measurement of the absorbance difference (ΔA), which represents the excess cerium (IV), at 317nm for each drug. On the other hand, the spectrofluorimetric method was based on measurement of the fluorescent of the produced cerium (III) at emission wavelength 354nm (λ excitation =255nm) for the concentrations studied for each drug. For both methods, the variables affecting the reactions were carefully investigated and the conditions were optimized. Linear relationships were found between either ΔA or the fluorescent of the produced cerium (III) values and the concentration of the studied drugs in a general concentration range of 2.0-24.0μgmL -1 , 20.0-24.0ngmL -1 with good correlation coefficients in the following range 0.9990-0.9999, 0.9990-0.9993 for spectrophotometric and spectrofluorimetric methods respectively. The limits of detection and quantitation of spectrophotometric method were found in general concentration range 0.190-0.787 and 0.634-2.624μgmL -1 respectively. For spectrofluorimetric method, the limits of detection and quantitation were found in general concentration range 4.77-9.52 and 15.91-31.74ngmL -1 respectively. The stoichiometry of the reaction was determined, and the reactions pathways were postulated. The analytical performance of the methods, in terms of accuracy and precision, were statistically validated and the results obtained were satisfactory. The methods have been successfully applied to the determination of the cited drugs in their commercial pharmaceutical formulations. Statistical comparison of the results with the reference methods showed excellent agreement and proved that no significant difference in the accuracy and precision. Copyright © 2017 Elsevier B.V. All rights reserved.
Zaazaa, Hala E; Mohamed, Afaf O; Hawwam, Maha A; Abdelkawy, Mohamed
2015-01-05
A simple, sensitive and selective spectrofluorimetric method has been developed for the determination of 3-methylflavone-8-carboxylic acid as the main active metabolite of flavoxate hydrochloride in human urine. The proposed method was based on the measurement of the native fluorescence of the metabolite in methanol at an emission wavelength 390 nm, upon excitation at 338 nm. Moreover, the urinary excretion pattern has been calculated using the proposed method. Taking the advantage that 3-methylflavone-8-carboxylic acid is also the alkaline degradate, the proposed method was applied to in vitro determination of flavoxate hydrochloride in tablets dosage form via the measurement of its corresponding degradate. The method was validated in accordance with the ICH requirements and statistically compared to the official method with no significant difference in performance. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ibrahim, F. A.; El-Yazbi, A. F.; Wagih, M. M.; Barary, M. A.
2017-09-01
Two highly sensitive, simple and selective spectrophotometric and spectrofluorimetric assays have been investigated for the analysis of ezogabine, levetiracetam and topiramate in their pure and in pharmaceutical dosage forms. The suggested methods depend on the condensation of the primary amino-groups in the three drugs with acetylacetone and formaldehyde according to Hantzsch reaction yielding highly fluorescent yellow colored dihydropyridine derivatives. The reaction products of ezogabine, levetiracetam and topiramate were measured spectrophotometrically at 418, 390 and 380 nm or spectrofluorimetrically at λem/ex of 495/425 nm, 490/415 nm and 488/410 nm, respectively. Various experimental conditions have been carefully studied to maximize the reaction yield. At the optimum reaction conditions, the calibration curves were rectilinear over the concentration ranges of 8-25, 60-180 and 80-200 μg/mL spectrophotometrically and 0.02-0.2, 0.2-1.2 and 0.2-1.5 μg/mL spectrofluorimetrically for ezogabine, levetiracetam and topiramate, respectively with good correlation coefficients. The suggested methods were applied successfully for the analysis of ezogabine, levetiracetam and topiramate in their commercial tablets with high percentage recoveries and negligible interference from various excipients in pharmaceutical dosage forms. The results were statistically analyzed and showed the absence of any significant difference between both developed and published methods. The procedures were validated and evaluated by the ICH guidelines revealing good reproducibility and accuracy. Therefore, the two proposed methods may be considered of high interest for practical and reliable analysis of ezogabine, levetiracetam and topiramate in pharmaceutical dosage forms.
El-Ashry, S M; El-Wasseef, D R; El-Sherbiny, D T; Salem, Y A
2015-09-01
Two simple, rapid, sensitive and precise spectrophotometric and spectrofluorimetric methods were developed for the determination of indacaterol maleate in bulk powder and capsules. Both methods were based on the direct measurement of the drug in methanol. In the spectrophotometric method (Method I) the absorbance was measured at 259 nm. The absorbance-concentration plot was rectilinear over the range 1.0-10.0 µg mL(-1) with a lower detection limit (LOD) of 0.078 µg mL(-1) and lower quantification limit (LOQ) of 0.238 µg mL(-1). Meanwhile in the spectrofluorimetric method (Method II) the native fluorescence was measured at 358 nm after excitation at 258 nm. The fluorescence-concentration plot was rectilinear over the range of 1.0-40.0 ng mL(-1) with an LOD of 0.075 ng mL(-1) and an LOQ of 0.226 ng mL(-1). The proposed methods were successfully applied to the determination of indacaterol maleate in capsules with average percent recoveries ± RSD% of 99.94 ± 0.96 for Method I and 99.97 ± 0.81 for Method II. In addition, the proposed methods were extended to a content uniformity test according to the United States Pharmacopoeia (USP) guidelines and were accurate, precise for the capsules studied with acceptance value 3.98 for Method I and 2.616 for Method II. Copyright © 2015 John Wiley & Sons, Ltd.
Fael, Hanan; Sakur, Amir Al-Haj
2015-11-01
A novel, simple and specific spectrofluorimetric method was developed and validated for the determination of perindopril erbumine (PDE). The method is based on the fluorescence quenching of Rhodamine B upon adding perindopril erbumine. The quenched fluorescence was monitored at 578 nm after excitation at 500 nm. The optimization of the reaction conditions such as the solvent, reagent concentration, and reaction time were investigated. Under the optimum conditions, the fluorescence quenching was linear over a concentration range of 1.0-6.0 μg/mL. The proposed method was fully validated and successfully applied to the analysis of perindopril erbumine in pure form and tablets. Statistical comparison of the results obtained by the developed and reference methods revealed no significant differences between the methods compared in terms of accuracy and precision. The method was shown to be highly specific in the presence of indapamide, a diuretic that is commonly combined with perindopril erbumine. The mechanism of rhodamine B quenching was also discussed.
Spectrofluorimetric determination of fluoroquinolones in pharmaceutical preparations.
Ulu, Sevgi Tatar
2009-02-01
Simple, rapid and highly sensitive spectrofluorimetric method is presented for the determination of four fluoroquinolone (FQ) drugs, ciprofloxacin, enoxacin, norfloxacin and moxifloxacin in pharmaceutical preparations. Proposed method is based on the derivatization of FQ with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 9.0 to yield a yellow product. The optimum experimental conditions have been studied carefully. Beer's law is obeyed over the concentration range of 23.5-500 ng mL(-1) for ciprofloxacin, 28.5-700 ng mL(-1) for enoxacin, 29.5-800 ng mL(-1) for norfloxacin and 33.5-1000 ng mL(-1) for moxifloxacin using NBD-Cl reagent, respectively. The detection limits were found to be 7.0 ng mL(-1) for ciprofloxacin, 8.5 ng mL(-1) for enoxacin, 9.2 ng mL(-1) for norfloxacin and 9.98 ng mL(-1) for moxifloxacin, respectively. Intra-day and inter-day relative standard deviation and relative mean error values at three different concentrations were determined. The low relative standard deviation values indicate good precision and high recovery values indicate accuracy of the proposed methods. The method is highly sensitive and specific. The results obtained are in good agreement with those obtained by the official and reference method. The results presented in this report show that the applied spectrofluorimetric method is acceptable for the determination of the four FQ in the pharmaceutical preparations. Common excipients used as additives in pharmaceutical preparations do not interfere with the proposed method.
Bavili Tabrizi, Ahad; Abdollahi, Ali
2015-10-01
A simple, rapid and sensitive spectrofluorimetric method was developed for the determination of di-syston, ethion and phorate in environmental water samples. The procedure is based on the oxidation of these pesticides with cerium (IV) to produce cerium (III), and its fluorescence was monitored at 368 ± 3 nm after excitation at 257 ± 3 nm. The variables effecting oxidation of each pesticide were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 0.2-15, 0.1-13, 0.1-13 ng mL(-1) for di-syston, ethion and phorate, respectively. The limit of detection and quantification were in the range 0.034-0.096 and 0.112-0.316 ng mL(-1), respectively. Intra- and inter-day assay precisions, expressed as the relative standard deviation (RSD), were lower than 5.2 % and 6.7 %, respectively. Good recoveries in the range 86 %-108 % were obtained for spiked water samples. The proposed method was applied to the determination of studied pesticides in environmental water samples.
Spectrofluorimetric assay method for glutathione and glutathione transferase using monobromobimane.
Yakubu, S I; Yakasai, I A; Musa, A
2011-06-01
The primary role of glutathione transferase is to defend an organism from toxicities through catalyzing the reaction of glutathione (GSH) with potentially toxic compounds or metabolites to their chemically and biologically inert conjugates. The objective of the study was to develop a simple and sensitive spectrofluorimetric assay method for glutathione transferase using monobromobimane (MBB), a non fluorescent compound with electrophilic site. MBB slowly reacted with glutathione to form fluorescent glutathione conjugate and that the reaction was catalysed by glutathione transferase. Both non-enzymatic and enzymatic reaction products of MBB, in presence of GSH in phosphate buffer (pH 6.5), were measured by following increase of fluorescence at wavelength of 475nm. For validation of the assay method, the kinetic parameters such as the apparent Michaelis-Mente constants and maximum rates of conjugate formation as well as the specific activity of rat hepatic glutathione transferase were determined. The method was found to be sensitive, thus, applied to measure glutathione contents of crude preparation of rat hepatic cytosol fraction.
Spectrofluorimetric determination of some water-soluble vitamins.
Mohamed, Abdel-Maaboud I; Mohamed, Horria A; Abdel-Latif, Niveen M; Mohamed, Marwa R
2011-01-01
Two simple and sensitive spectrofluorimetric methods were developed for determination of three water-soluble vitamins (B1, B2, and B6) in mixtures in the presence of cyanocobalamin. The first one was for thiamine determination, which depends on the oxidation of thiamine HCl to thiochrome by iodine in an alkaline medium. The method was applied accurately to determine thiamine in binary, ternary, and quaternary mixtures with pyridoxine HCl, riboflavin, and cyanocobalamin without interference. In the second method, riboflavin and pyridoxine HCl were determined fluorimetrically in acetate buffer, pH 6. The three water-soluble vitamins (B1, B2, and B6) were determined spectrofluorimetrically in binary, ternary, and quaternary mixtures in the presence of cyanocobalamin. All variables were studied in order to optimize the reaction conditions. Linear relationship was obeyed for all studied vitamins by the proposed methods at their corresponding lambda(exc) or lambda(em). The linear calibration curves were obtained from 10 to 500 ng/mL; the correlation ranged from 0.9991 to 0.9999. The suggested procedures were applied to the analysis of the investigated vitamins in their laboratory-prepared mixtures and pharmaceutical dosage forms from different manufacturers. The RSD range was 0.46-1.02%, which indicates good precision. No interference was observed from common pharmaceutical additives. Good recoveries (97.6 +/- 0.7-101.2 +/- 0.8%) were obtained. Statistical comparison of the results with reported methods shows excellent agreement and indicates no significant difference in accuracy and precision.
Alarfaj, Nawal A; El-Tohamy, Maha F
2013-01-01
A simple and sensitive spectrofluorimetric method was developed for the determination of Ribavirin in pharmaceutical formulations. The proposed method was based on the fluorescence spectral behaviour of Ribavirin in a sodium dodecyl sulfate (SDS) micellar system. In an aqueous acetate buffer solution of pH 4.0, the fluorescence intensity of Ribavirin was significantly enhanced by about 217% in the presence of SDS. Fluorescence intensity was measured at 396 nm after excitation at 270 nm for Ribavirin. The fluorescence-concentration plot was rectilinear over the range of 0.01-3.0 µg/mL for Ribavirin with a lower detection limit of 5.02 x 10(-3) µg/mL. The method was successfully applied to the analysis of the drug in its commercial capsules. Results were in good agreement with those obtained with the official method. The application of the proposed method was extended to stability studies of Ribavirin after exposure to different forced degradation conditions such as acidic, alkaline, photo and oxidative conditions according to ICH guidelines. Copyright © 2012 John Wiley & Sons, Ltd.
Alarfaj, Nawal A; Aly, Fatma A
2012-01-01
A simple and sensitive spectrofluorimetric method was developed for the determination of ezetimibe in its pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behavior of ezetimibe in sodium dodecyl sulfate (SDS) micellar system. In aqueous solution of acetate buffer pH 5.0, the fluorescence intensity of ezetimibe was greatly enhanced, 200% enhancement, in the presence of SDS. The fluorescence intensity of ezetimibe was measured at 380 nm after excitation at 268 nm. The fluorescence-concentration plot was rectilinear over the range of 0.03-3.0 μg/mL with lower detection limit of 3.08 × 10(-3) μg/mL. The method was successfully applied to the analysis of ezetimibe in its commercial tablets; the results were in good agreement with those obtained with the reported method. The application of the proposed method was extended to the stability studies of ezetimibe after exposure to different forced degradation conditions, such as acidic, alkaline, photo and oxidative conditions, according to ICH guidelines.
Belal, Tarek Saied
2008-09-01
A simple, rapid, selective and sensitive spectrofluorimetric method was described for the analysis of three nitrofuran drugs, namely, nifuroxazide (NX), nitrofurantoin (NT) and nitrofurazone (NZ). The method involved the alkaline hydrolysis of the studied drugs by warming with 0.1 M sodium hydroxide solution then dilution with distilled water for NX or 2-propanol for NT and NZ. The formed fluorophores were measured at 465 nm (lambda (Ex) 265 nm), 458 nm (lambda (Ex) 245 nm) and 445 nm (lambda (Ex) 245 nm) for NX, NT and NZ, respectively. The reaction pathway was discussed and the structures of the fluorescent products were proposed. The different experimental parameters were studied and optimized. Regression analysis showed good correlation between fluorescence intensity and concentration over the ranges 0.08-1.00, 0.02-0.24 and 0.004-0.050 microg ml(-1) for NX, NT and NZ, respectively. The limits of detection of the method were 8.0, 1.9 and 0.3 ng ml(-1) for NX, NT and NZ, respectively. The proposed method was validated in terms of accuracy, precision and specificity, and it was successfully applied for the assay of the three nitrofurans in their different dosage forms. No interference was observed from common pharmaceutical adjuvants. The results were favorably compared with those obtained by reference spectrophotometric methods.
Darwish, Ibrahim A.; Amer, Sawsan M.; Abdine, Heba H.; Al-Rayes, Lama I.
2008-01-01
New simple spectrofluorimetric method with enhanced sensitivity has been developed and validated for the determination of the antidepressant paroxetine (PXT) in its dosage forms and plasma. The method was based on nucleophilic substitution reaction of PXT with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole in an alkaline medium (pH 8) to form a highly fluorescent derivative that was measured at 545 nm after excitation at 490 nm. The factors affecting the reaction was carefully studied and optimized. The kinetics of the reaction was investigated, and the reaction mechanism was presented. Under the optimized conditions, linear relationship with good correlation coefficient (0.9993) was found between the fluorescence intensity and PXT concentration in the range of 80–800 ng ml−1. The limits of detection and quantitation for the method were 25 and 77 ng ml−1, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 3%. The proposed method was successfully applied to the determination of PXT in its pharmaceutical tablets with good accuracy; the recovery values were 100.2 ± 1.61%. The results obtained by the proposed method were comparable with those obtained by the official method. The proposed method is superior to the previously reported spectrofluorimetric method for determination of PXT in terms of its higher sensitivity and wider linear range. The high sensitivity of the method allowed its successful application to the analysis of PXT in spiked human plasma. The proposed method is practical and valuable for its routine application in quality control and clinical laboratories for analysis of PXT. PMID:19609398
Walash, M. I.; Rizk, M.; Sheribah, Z. A.; Salim, M. M.
2010-01-01
A simple and sensitive spectrofluorimetric method was developed for the determination of biotin in pure form and in pharmaceutical preparations. The proposed method is based on the oxidation of the drug with cerium (IV) ammonium sulfate in acidic medium. The fluorescence of the produced Cerium (III) was measured at 365 nm after excitation at 255 nm. The different experimental parameters affecting the development and stability of the reaction were carefully studied and optimized. The method is applicable over the concentration range of 30-120 ng/mL with correlation coefficient of 0.9998. The detection limit (LOD) of biotin was 2.41 ng/mL while quantitation limit (LOQ) was 7.29 ng/mL. The proposed procedure was successfully applied for the determination of biotin in pharmaceutical preparations with mean recoveries of 99.55 ± 0.83 and 101.67 ± 1.53 for biotin ampoules and capsules, respectively. The results obtained were in good agreement with those obtained using the official method. PMID:23675202
Walash, Mohammed I; El-Enany, Nahed; Askar, Hanany
2015-11-01
A sensitive and simple spectrofluorimetric method has been developed and validated for the determination of the anti-epileptic drug carbamazepine (CBZ) in its dosage forms. The method was based on a nucleophilic substitution reaction of CBZ with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) in borate buffer (pH 9) to form a highly fluorescent derivative that was measured at 530 nm after excitation at 460 nm. Factors affecting the formation of the reaction product were studied and optimized, and the reaction mechanism was postulated. The fluorescence-concentration plot is rectilinear over the range of 0.6-8 µg/mL with limit of detection of 0.06 µg/mL and limit of quantitation of 0.19 µg/mL. The method was applied to the analysis of commercial tablets and the results were in good agreement with those obtained using the reference method. Validation of the analytical procedures was evaluated according to ICH guidelines. Copyright © 2015 John Wiley & Sons, Ltd.
Gallo, Alessandra; Boni, Raffaele; Tosti, Elisabetta
2018-01-01
The viability of spermatozoa is a crucial parameter to evaluate their quality that is an important issue in ecotoxicological studies. Here, a new method has been developed to rapidly determine the viability of spermatozoa in three marine invertebrates: the ascidian Ciona intestinalis, the sea urchin Paracentrotus lividus and the mollusc Mytilus galloprovincialis. This method employed the dual DNA fluorescent staining coupled with spectrofluorimetric analysis. The dual fluorescent staining used the SYBR-14 stained live spermatozoa and propidium iodide stained degenerated cells that had lost membrane integrity. Stain uptake was assessed by confocal microscopy and then the percentage of live and dead spermatozoa was quantified by spectrofluorimetric analysis. The microscopic examination revealed three populations of spermatozoa: living-SYBR-14 stained, dead-PI stained, and dying-doubly stained spermatozoa. The fluorescence emission peak values recorded in a spectrofluorimeter provide the portion of live and dead spermatozoa showing a significant negative correlation. The stain combination was further validated using known ratios of live and dead spermatozoa. The present study demonstrated that the dual DNA staining with SYBR-14 and propidium iodide was effective in assessing viability of spermatozoa in marine invertebrates and that spectrofluorimetric analysis can be successfully employed to evaluate the percentage of live and dead spermatozoa. The method develop herein is simple, accurate, rapid, sensitive, and cost-effective, so it could be a useful tool by which marine pollutants may be screened for spermiotoxicity. Copyright © 2017 Elsevier Inc. All rights reserved.
Tekkeli, Serife Evrim Kepekci; Önal, Armağan; Sağırlı, A Olcay
2014-02-01
A simple, sensitive and selective spectrofluorimetric method has been developed for the determination of tobramycin (TOB) in human serum and pharmaceutical preparations. The method is based on the reaction between the primary amino group of TOB and fluorescamine in borate buffer, pH 8.5, to give a highly fluorescent derivative which is measured at 469 nm after excitation at 388 nm. The fluorescence intensity was directly proportional to the concentration over the range 300-1500 ng/mL, with a limit of detection of 65 ng/mL and limit of quantitation of 215 ng/mL. All variables were investigated to optimize the reaction conditions. The method was validated according to International Conference on Harmonization guidelines in terms of specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. Good recoveries were obtained ranging from 97.4 to 100.64%, indicating that no interference was observed from concomitants usually present in pharmaceutical dosage forms. The method was successfully, applied for the analysis of the drug substance in its pharmaceutical preparations and spiked serum samples. Copyright © 2013 John Wiley & Sons, Ltd.
Ibrahim, Fawzia; El-Enany, Nahed; Shalan, Shereen; Elsharawy, Rasha
2016-05-01
A simple, highly sensitive and validated spectrofluorimetric method was applied in the determination of clonazepam (CLZ). The method is based on reduction of the nitro group of clonazepam with zinc/CaCl2, and the product is then reacted with 2-cyanoacetamide (2-CNA) in the presence of ammonia (25%) yielding a highly fluorescent product. The produced fluorophore exhibits strong fluorescence intensity at ʎ(em) = 383 nm after excitation at ʎ(ex) = 333 nm. The method was rectilinear over a concentration range of 0.1-0.5 ng/mL with a limit of detection (LOD) of 0.0057 ng/mL and a limit of quantification (LOQ) of 0.017 ng/mL. The method was fully validated and successfully applied to the determination of CLZ in its tablets with a mean percentage recovery of 100.10 ± 0.75%. Method validation according to ICH Guidelines was evaluated. Statistical analysis of the results obtained using the proposed method was successfully compared with those obtained using a reference method, and there was no significance difference between the two methods in terms of accuracy and precision. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Peng, Qian; Hou, Faju; Jiang, Chongqiu
2006-09-01
A new spectrofluorimetric method was developed for determination of trace amount of Coenzyme II (NADP). Using europium ion-doxycycline (DC) as a fluorescent probe, in the buffer solution of pH 8.44, NADP can remarkably enhance the fluorescence intensity of the Eu 3+-DC complex at λ = 612 nm and the enhanced fluorescence intensity is in proportion to the concentration of NADP. Optimum conditions for the determination of NADP were also investigated. The dynamic range for the determination of NADP is 3.3 × 10 -7 to 6.1 × 10 -6 mol l -1 with detection limit of 6.8 × 10 -8 mol l -1. This method is simple, practical and relatively free interference from coexisting substances and can be successfully applied to determination of NADP in synthetic water samples and in serum samples. Moreover, the enhancement mechanisms of the fluorescence intensity in the Eu 3+-DC system and the Eu 3+-DC-NADP system have been also discussed.
Youssef, A O
2012-05-01
A new, simple, sensitive and selective spectrofluorimetric method for the determination of Hydrochlorothiazide was developed in acetonitrile at pH 6.2. The Hydrochlorothiazide can remarkably enhance the luminescence intensity of the Tb(3+) ion doped in sol-gel matrix at λ(ex) = 370 nm. The intensity of the emission band of Tb(3+) ion doped in sol-gel matrix was increased due to the energy transfer from the triplet excited state of Hydrochlorothiazide to ((5)D(4)) excited energy state of Tb(3) ion. The enhancement of the emission band of Tb(3+) ion doped in sol-gel matrix at ((5)D(4)→(7)F(5)) 545 nm was directly proportion to the concentration of Hydrochlorothiazide with a dynamic ranges of 5.0 × 10(-10)-5.0 × 10(-6) mol L(-1) and detection limit of 2.2 × 10(-11) mol L(-1).
Attia, M S; Aboaly, M M
2010-06-30
A simple, sensitive and selective spectrofluorimetric method for the determination of Metoclopramide hydrochloride (MCP) is developed. The MCP can remarkably enhances the luminescence intensity of the Eu(3+) ion doped in sol-gel matrix at lambda(ex)=380 nm in DMSO at pH 8.7. The intensity of the emission band of Eu(3+) ion doped in sol-gel matrix increases due to energy transfer from MCP to Eu(3+) in the excited state. The enhancement of the emission band of Eu(3+) ion doped in sol-gel matrix at 617 nm was found to be directly proportional to the concentration of MCP with a dynamic range of 5 x 10(-9) - 1.0 x 10(-6) mol L(-1) and detection limit of 2.2 x10(-11) mol L(-1). Copyright 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Alamgir, Malik; Khuhawar, Muhammad Yar; Memon, Saima Q.; Hayat, Amir; Zounr, Rizwan Ali
2015-01-01
A sensitive and simple spectrofluorimetric method has been developed for the analysis of famotidine, from pharmaceutical preparations and biological fluids after derivatization with benzoin. The reaction was carried out in alkaline medium with measurement of fluorescence intensity at 446 nm with excitation wavelength at 286 nm. Linear calibration was obtained with 0.5-15 μg/ml with coefficient of determination (r2) 0.997. The factors affecting the fluorescence intensity were optimized. The pharmaceutical additives and amino acid did not interfere in the determination. The mean percentage recovery (n = 4) calculated by standard addition from pharmaceutical preparation was 94.8-98.2% with relative standard deviation (RSD) 1.56-3.34% and recovery from deproteinized spiked serum and urine of healthy volunteers was 98.6-98.9% and 98.0-98.4% with RSD 0.34-0.84% and 0.29-0.87% respectively.
NASA Astrophysics Data System (ADS)
Asadpour-Zeynali, Karim; Bastami, Mohammad
2010-02-01
In this work a new modification of the standard addition method called "net analyte signal standard addition method (NASSAM)" is presented for the simultaneous spectrofluorimetric and spectrophotometric analysis. The proposed method combines the advantages of standard addition method with those of net analyte signal concept. The method can be applied for the determination of analyte in the presence of known interferents. The accuracy of the predictions against H-point standard addition method is not dependent on the shape of the analyte and interferent spectra. The method was successfully applied to simultaneous spectrofluorimetric and spectrophotometric determination of pyridoxine (PY) and melatonin (MT) in synthetic mixtures and in a pharmaceutical formulation.
NASA Astrophysics Data System (ADS)
Derayea, Sayed M.; Omar, Mahmoud A.; Abu-hassan, Ahmed A.
2018-03-01
A simple, sensitive and non-extractive spectrofluorimetric method has been developed and validated for the determination of two psychoanaleptic drugs, atomoxetine and fluvoxamine, in pure forms and pharmaceutical dosage forms. The proposed method is based on the formation of binary complexes between eosin Y and the studied drugs in the presence of a Teorell-Stenhagen buffer. The quenching of the native fluorescence of eosin Y due to complex formation with the studied drugs was measured spectrofluorimetrically at 545 nm after excitation at 302 nm. At the optimum reaction conditions, the fluorescence quenching values (ΔF) and concentrations were rectilinear over the concentration ranges of 0.2-2.2 and 0.3-2.2 µg ml-1 for atomoxetine and fluvoxamine, respectively. The developed method was successfully applied for the determination of the studied drugs in their pharmaceutical formulations with average percentage recoveries of 100.13 ± 0.66 and 99.69 ± 0.44 for atomoxetine and fluvoxamine, respectively (n = 5), without interference from common excipients.
Omar, Mahmoud A.; Abu-hassan, Ahmed A.
2018-01-01
A simple, sensitive and non-extractive spectrofluorimetric method has been developed and validated for the determination of two psychoanaleptic drugs, atomoxetine and fluvoxamine, in pure forms and pharmaceutical dosage forms. The proposed method is based on the formation of binary complexes between eosin Y and the studied drugs in the presence of a Teorell–Stenhagen buffer. The quenching of the native fluorescence of eosin Y due to complex formation with the studied drugs was measured spectrofluorimetrically at 545 nm after excitation at 302 nm. At the optimum reaction conditions, the fluorescence quenching values (ΔF) and concentrations were rectilinear over the concentration ranges of 0.2–2.2 and 0.3–2.2 µg ml−1 for atomoxetine and fluvoxamine, respectively. The developed method was successfully applied for the determination of the studied drugs in their pharmaceutical formulations with average percentage recoveries of 100.13 ± 0.66 and 99.69 ± 0.44 for atomoxetine and fluvoxamine, respectively (n = 5), without interference from common excipients. PMID:29657744
Mohamed, Abdel-Maaboud I; Omar, Mahmoud A; Hammad, Mohamed A; Mohamed, Abobakr A
2016-11-01
A highly sensitive and simple spectrofluorimetric method was developed for the determination of Amlodipine besylate (AML) in its pharmaceutical formulations and spiked human plasma. The proposed method is based on the investigation of the fluorescence spectral behaviour of AML in Tween-80 micellar system. In aqueous solution, the fluorescence intensity of AML was greatly enhanced (160 %) in the presence of Tween-80. The fluorescence intensity was measured at 427 nm after excitation at 385 nm. The fluorescence-concentration plot was rectilinear over the concentration range 0.1-4.0 μg/ml, with lower detection limit of 0.03 μg/ml. The suggested method was successfully applied for the analysis of AML in its commercial tablets alone or in combination with either Atorvastatin or Valsartan. The application of the proposed method was extended to the assay of AML in spiked human plasma and stability studies of AML after exposure to different forced degradation conditions, such as acidic, alkaline, photo- and oxidative conditions, according to ICH guidelines. The results were statistically compared to those obtained by comparison methods and were found to be in good agreement.
Omar, Mahmoud A; Hammad, Mohamed A; Nagy, Dalia M; Aly, Alshymaa A
2015-02-05
A simple and sensitive spectrofluorimetric method has been developed and validated for determination of amikacin sulfate, neomycin sulfate and tobramycin in pure forms, pharmaceutical formulations and human plasma. The method was based on condensation reaction of cited drugs with ninhydrin and phenylacetaldehyde in buffered medium (pH 6) resulting in formation of fluorescent products which exhibit excitation and emission maxima at 395 and 470nm, respectively. The different experimental parameters affecting the development and stability of the reaction products were carefully studied and optimized. The calibration plots were constructed with good correlation coefficients (0.9993 for tobramycin and 0.9996 for both neomycin and amikacin). The proposed method was successfully applied for the analysis of cited drugs in dosage forms with high accuracy (98.33-101.7)±(0.80-1.26)%. The results show an excellent agreement with the reference method, indicating no significant difference in accuracy and precision. Due to its high sensitivity, the proposed method was applied successfully for determination of amikacin in real human plasma. Copyright © 2014 Elsevier B.V. All rights reserved.
Vanlı, Elvan; Mısır, Miraç Nedim; Alp, Hakan; Ak, Tuğba; Özbek, Nurhayat; Ocak, Ümmühan; Ocak, Miraç
2017-09-01
Four fluorescent Schiff bases carrying dipicolylamine groups were designed and synthesized to determine their ion sensor properties in partial aqueous solution. The corresponding amine compound and the aldehyde compounds such as 1-naphthaldehyde, 9-anthraldehyde, phenanthrene-9-carboxaldehyde and 1-pyrenecarboxaldehyde were used to prepare the new Schiff bases. The influence of many metal cations and anions on the spectroscopic properties of the ligands was investigated in ethanol-water (1:1) by means of emission spectrometry. From the spectrofluorimetric titrations, the complexation stoichiometry and complex stability constants of the ligands with Cd 2+ , Zn 2+ , Cu 2+ and Hg 2+ ions were determined. The ligands did not interact with the anions. However, the Schiff base derived from phenanthrene-9-carboxaldehyde showed sensitivity for Cu 2+ among the tested metal ions. The phenanthrene-based Schiff base was used as analytical ligand for the simple and fast determination of Cu 2+ ion in water samples. A modified standard addition method was used to eliminate matrix effect. The linear range was from 0.3 mg/L to 3.8 μg/L. Detection and quantification limits were 0.14 and 0.43 mg/L, respectively. Maximum contaminant level goal (MCLG) for copper in drinking water according to EPA is 1.3 mg/L. The proposed method has high sensitivity to determine copper in drinking waters.
Pistonesi, Marcelo F; Di Nezio, María S; Centurión, María E; Lista, Adriana G; Fragoso, Wallace D; Pontes, Márcio J C; Araújo, Mário C U; Band, Beatriz S Fernández
2010-12-15
In this study, a novel, simple, and efficient spectrofluorimetric method to determine directly and simultaneously five phenolic compounds (hydroquinone, resorcinol, phenol, m-cresol and p-cresol) in air samples is presented. For this purpose, variable selection by the successive projections algorithm (SPA) is used in order to obtain simple multiple linear regression (MLR) models based on a small subset of wavelengths. For comparison, partial least square (PLS) regression is also employed in full-spectrum. The concentrations of the calibration matrix ranged from 0.02 to 0.2 mg L(-1) for hydroquinone, from 0.05 to 0.6 mg L(-1) for resorcinol, and from 0.05 to 0.4 mg L(-1) for phenol, m-cresol and p-cresol; incidentally, such ranges are in accordance with the Argentinean environmental legislation. To verify the accuracy of the proposed method a recovery study on real air samples of smoking environment was carried out with satisfactory results (94-104%). The advantage of the proposed method is that it requires only spectrofluorimetric measurements of samples and chemometric modeling for simultaneous determination of five phenols. With it, air is simply sampled and no pre-treatment sample is needed (i.e., separation steps and derivatization reagents are avoided) that means a great saving of time. Copyright © 2010 Elsevier B.V. All rights reserved.
Attia, M S; Ramsis, M N; Khalil, L H; Hashem, S G
2012-03-01
A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of trace amounts of chlorzoxazone and Ibuprofen in pharmaceutical tablets using optical sensor Eu-Tetracycline HCl doped in sol-gel matrix. The chlorzoxazone or Ibuprofen can remarkably enhance the luminescence intensity of Eu-Tetracycline HCl complex doped in a sol-gel matrix in dimethylformamide (DMF) at pH 9.7 and 6.3, respectively, λ(ex) = 400 nm. The enhancing of luminescence intensity peak of Eu-Tetracycline HCl complex at 617 nm is proportional to the concentration of chlorzoxazone or Ibuprofen a result that suggested profitable application as a simple optical sensor for chlorzoxazone or Ibuprofen assessment. The dynamic ranges found for the determination of chlorzoxazone and Ibuprofen concentration are 5 × 10(-9)-1 × 10(-4) and 1 × 10(-8)-7 × 10(-5) mol L(-1), and the limit of detection (LOD) and quantitation limit of detection (LOQ) are 3.1 × 10(-10), 9.6 × 10(-10) and 5.6 × 10(-10), 1.7 × 10(-9) mol L(-1), respectively.
Maher, Hadir M; Alshehri, Mona M; Al-taweel, Shorog M
2015-05-01
Rapid, simple and sensitive derivative emission spectrofluorimetric methods have been developed for the simultaneous analysis of binary mixtures of guaifenesin (GUA) and phenylephrine hydrochloride (PHE). The methods are based upon measurement of the native fluorescence intensity of the two drugs at λex = 275 nm in methanolic solutions, followed by differentiation using first (D1) and second (D2) derivative techniques. The derivative fluorescence intensity-concentration plots were rectilinear over a range of 0.1-2 µg/mL for both GUA and PHE. The limits of detection were 0.027 (D1, GUA), 0.025 (D2, GUA), 0.031 (D1, PHE) and 0.033 (D2, PHE) µg/mL and limits of quantitation were 0.089 (D1, GUA), 0.083 (D2, GUA), 0.095 (D1, PHE) and 0.097 (D2, PHE) µg/mL. The proposed derivative emission spectrofluorimetric methods (D1 and D2) were successfully applied for the determination of the two compounds in binary mixtures and tablets with high precision and accuracy. The proposed methods were fully validated as per ICH guidelines. Copyright © 2014 John Wiley & Sons, Ltd.
Piccirilli, Gisela N; Escandar, Graciela M
2006-09-01
This paper demonstrates for the first time the power of a chemometric second-order algorithm for predicting, in a simple way and using spectrofluorimetric data, the concentration of analytes in the presence of both the inner-filter effect and unsuspected species. The simultaneous determination of the systemic fungicides carbendazim and thiabendazole was achieved and employed for the discussion of the scopes of the applied second-order chemometric tools: parallel factor analysis (PARAFAC) and partial least-squares with residual bilinearization (PLS/RBL). The chemometric study was performed using fluorescence excitation-emission matrices obtained after the extraction of the analytes over a C18-membrane surface. The ability of PLS/RBL to recognize and overcome the significant changes produced by thiabendazole in both the excitation and emission spectra of carbendazim is demonstrated. The high performance of the selected PLS/RBL method was established with the determination of both pesticides in artificial and real samples.
Alamgir, Malik; Khuhawar, Muhammad Yar; Memon, Saima Q; Hayat, Amir; Zounr, Rizwan Ali
2015-01-05
A sensitive and simple spectrofluorimetric method has been developed for the analysis of famotidine, from pharmaceutical preparations and biological fluids after derivatization with benzoin. The reaction was carried out in alkaline medium with measurement of fluorescence intensity at 446 nm with excitation wavelength at 286 nm. Linear calibration was obtained with 0.5-15 μg/ml with coefficient of determination (r(2)) 0.997. The factors affecting the fluorescence intensity were optimized. The pharmaceutical additives and amino acid did not interfere in the determination. The mean percentage recovery (n=4) calculated by standard addition from pharmaceutical preparation was 94.8-98.2% with relative standard deviation (RSD) 1.56-3.34% and recovery from deproteinized spiked serum and urine of healthy volunteers was 98.6-98.9% and 98.0-98.4% with RSD 0.34-0.84% and 0.29-0.87% respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Xia, Qinghai; Yang, Yaling; Liu, Mousheng
2012-10-01
An aluminium sensitized spectrofluorimetric method coupled with salting-out assisted liquid-liquid ultrasonic extraction for the determination of four widely used fluoroquinolones (FQs) namely norfloxacin (NOR), ofloxacin (OFL), ciprofloxacin (CIP) and gatifloxacin (GAT) in bovine raw milk was described. The analytical procedure involves the fluorescence sensitization of aluminium (Al3+) by complexation with FQs, salting-out assisted liquid-liquid ultrasonic extraction (SALLUE), followed by spectrofluorometry. The influence of several parameters on the extraction (the salt species, the amount of salt, pH, temperature and phase volume ratio) was investigated. Under optimized experimental conditions, the detection limits of the method in milk varied from 0.009 μg/mL for NOR to 0.016 μg/mL for GAT (signal-to-noise ratio (S/N) = 3). The relative standard deviations (RSD) values were found to be relatively low (0.54-2.48% for four compounds). The calibration graph was linear from 0.015 to 2.25 μg/mL with coefficient of determinations not less than 0.9974. The methodology developed was applied to the determination of FQs in bovine raw milk samples. The main advantage of this method is simple, accurate and green. The method showed promising applications for analyzing polar analytes especially polar drugs in various sample matrices.
Walash, Mohamed I; Ibrahim, Fawzia; Eid, Manal I; El Abass, Samah Abo
2013-11-01
A simple, sensitive and rapid spectrofluorimetric method for determination of itopride hydrochloride in raw material and tablets has been developed. The proposed method is based on the measurement of the native fluorescence of the drug in water at 363 nm after excitation at 255 nm. The relative fluorescence intensity-concentration plot was rectilinear over the range of 0.1-2 μg/mL (2.5 × 10(-7)-5.06 × 10(-6) mole/L), with good correlation (r = 0.9999), limit of detection of 0.015 μg/mL and a lower limit of quantification of 0.045 μg/mL. The described method was successfully applied for the determination of itopride hydrochloride in its commercial tablets with average percentage recovery of 100.11 ± 0.32 without interference from common excipients. Additionally, the proposed method can be applied for determination of itopride in combined tablets with rabeprazole or pantoprazole without prior separation. The method was extended to stability study of itopride. The drug was exposed to acidic, alkaline, oxidative and photolytic degradation according to ICH guidelines. Moreover, the method was utilized to investigate the kinetics of the alkaline, acidic and oxidative degradation of the drug. A proposal for the degradation pathways was postulated.
NASA Astrophysics Data System (ADS)
Al-Attas, Amirah S.; Nasr, Jenny Jeehan; Shalan, Shereen; Belal, Fathalla
2017-06-01
A simple, fast, sensitive and stability-indicating derivative spectrofluorimetric method is presented for the assay of zopiclone (ZOP), a drug with hypnotic effect, and its main degradation product and major contaminant, 2-amino-5-chloropyridine (ACP). The method is based on measuring the inherent fluorescence intensity of both drugs at λex = 300 nm in methanol, then differentiation using D1 (first derivative technique). The developed method was found to be rectilinear over a range of 0.2-4 μg/mL of ZOP and 4-100 ng/mL of ACP. The limits of detection were 0.05 μg/mL of ZOP and 0.2 ng/mL of ACP with the limit of quantitation of 0.17 μg/mL of ZOP and 0.7 ng/mL of ACP. The outcoming results of the proposed method were compared to those obtained by a reference method showing no significant statistical difference between them concerning precision and accuracy. Additionally, the developed method was applied for detecting ACP in spiked human urine and plasma specimens as a tool of clinical evidence of zopiclone intake that can be easily implemented in forensic laboratories. The proposed method was validated as per ICH guidelines.
Saccomanni, G; Giorgi, M; Del Carlo, S; Manera, C; Saba, A; Macchia, M
2011-09-01
Parecoxib is the injectable prodrug of valdecoxib, a cicloxygenase-2 selective drug, currently used in human medicine. Recent studies have suggested both its excellent clinical effectiveness and wide safety profile. The aim of the present study was to develop and validate a new high-performance liquid chromatography (HPLC) with spectrofluorimetric detection method to quantify parecoxib and valdecoxib in canine plasma. Several parameters both in the extraction and the detection method were evaluated. The applicability of the method was determined by administering parecoxib to one dog: the protocol provided the expected pharmacokinetic results. The final mobile phase was acetonitrile: AcONH(4) (10 mM; pH 5.0) 55:45, v/v, with a flow rate of 0.4 mL min(-1), and excitation and emission wavelengths of 265 and 375 nm, respectively. The analytical column was a reverse-phase C18 ODS2 3-μm particle size. Protein precipitation in acidic medium followed by two successive liquid-liquid steps was carried out. The best extraction solvent was cyclohexane:Et(2)O (3:2, v/v) that gave recoveries ranging from 81.1% to 89.1% and from 94.8% to 103.6% for parecoxib and valdecoxib, respectively. The limits of quantification were 25 and 10 ng mL(-1) for parecoxib and valdecoxib, respectively. The chromatographic runs were specific with no interfering peaks at the retention times of the analytes, as confirmed by HPLC-mass spectrometry experiments. The other validation parameters were in agreement with the European Medicines Evaluation Agency and International Conference on Harmonisation guidelines. In conclusion, this method (extraction, separation and applied techniques) is simple and effective. This is the first time that use of a HPLC with spectrofluorimetric detection technique to simultaneously detect parecoxib and valdecoxib in plasma has been reported. This technique may have applications for pharmacokinetic studies.
Awad, Mohamed; Hammad, Mohamed A; Abdel-Megied, Ahmed M; Omar, Mahmoud A
2018-04-30
Simple, precise and selective spectrofluorimetric technique was evolved for quantitation of selective β 2 agonist drug namely salmeterol xinafoate (SAL). Utilizing its phenolic nature, a method was described based on the reaction of the studied drug with ethyl acetoacetate (EAA) to yield extremely fluorescent coumarin product which can be detected at 480 nm (λ ex = 420 nm). The procedure obeys Beer's law with a correlation coefficient of r = 0.9999 in the concentration range between 500 and 5000 ng ml -1 with and 177 ng ml -1 for limit of detection (LOD) and limit of quantification (LOQ), respectively. Diverse reaction variables influencing the firmness and formation of the coumarin product were accurately examined and modified to ensure greatest sensitivity of the procedure. The proposed technique was performed and examined according to the US Food and Drug Administration (FDA) guidelines for bio-analytical methods and was efficiently applied for quantitation of SAL in both pharmaceutical preparations (% recovery = 100.06 ± 1.07) and spiked human plasma (% recovery = 96.64-97.14 ± 1.01-1.52). Copyright © 2018 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Guo, Changchuan; Wang, Lei; Hou, Zhun; Jiang, Wei; Sang, Lihong
2009-05-01
A terbium-sensitized spectrofluorimetric method using an anionic surfactant, sodium dodecyl benzene sulfonate (SDBS), was developed for the determination of gatifloxacin (GFLX). A coordination complex system of GFLX-Tb 3+-SDBS was studied. It was found that SDBS significantly enhanced the fluorescence intensity of the complex (about 11-fold). Optimal experimental conditions were determined as follows: excitation and emission wavelengths of 331 and 547 nm, pH 7.0, 2.0 × 10 -4 mol l -1 terbium (III), and 2.0 × 10 -4 mol l -1 SDBS. The enhanced fluorescence intensity of the system (Δ If) showed a good linear relationship with the concentration of GFLX over the range of 5.0 × 10 -10 to 5.0 × 10 -8 mol l -1 with a correlation coefficient of 0.9996. The detection limit (3 σ) was determined as 6.0 × 10 -11 mol l -1. This method has been successfully applied to the determination of GFLX in pharmaceuticals and human urine/serum samples. Compared with most of other methods reported, the rapid and simple procedure proposed in the text offers higher sensitivity, wider linear range, and better stability. The interaction mechanism of the system is also studied by the research of ultraviolet absorption spectra, surface tension, solution polarity and fluorescence polarization.
2011-01-01
Two sensitive, selective, economic, and validated spectrofluorimetric methods were developed for the determination of ebastine (EBS) in pharmaceutical preparations depending on reaction with its tertiary amino group. Method I involves condensation of the drug with mixed anhydrides (citric and acetic anhydrides) producing a product with intense fluorescence, which was measured at 496 nm after excitation at 388 nm. Method (IIA) describes quantitative fluorescence quenching of eosin upon addition of the studied drug where the decrease in the fluorescence intensity was directly proportional to the concentration of ebastine; the fluorescence quenching was measured at 553 nm after excitation at 457 nm. This method was extended to (Method IIB) to apply first and second derivative synchronous spectrofluorimetric method (FDSFS & SDSFS) for the simultaneous analysis of EBS in presence of its alkaline, acidic, and UV degradation products. The proposed methods were successfully applied for the determination of the studied compound in its dosage forms. The results obtained were in good agreement with those obtained by a comparison method. Both methods were utilized to investigate the kinetics of the degradation of the drug. PMID:21385439
El-Masry, Amal A; Hammouda, Mohammed E A; El-Wasseef, Dalia R; El-Ashry, Saadia M
2017-03-01
A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of azelastine HCl (AZL) in either its pure state or pharmaceutical dosage form. The proposed method was based on measuring the native fluorescence of the studied drug in 0.2 M H 2 SO 4 at λ em = 364 nm after excitation at λ ex = 275 nm. Different experimental parameters were studied and optimized carefully to obtain the highest fluorescence intensity. The proposed method showed a linear dependence of the fluorescence intensity on drug concentration over a concentration range of 10-250 ng/mL, with a limit of detection of 1.52 ng/mL and limit of quantitation of 4.61 ng/mL. Moreover, the method was successfully applied to pharmaceutical preparations, with percent recovery values (± SD) of 99.96 (± 0.4) and 100.1 (± 0.52) for nasal spray and eye drops, respectively. The results were in good agreement with those obtained by the comparison method, as revealed by Student's t-test and the variance ratio F-test. The method was extended to study the stability of AZL under stress conditions, where the drug was exposed to neutral, acidic, alkaline, oxidative and photolytic degradation according to International Conference on Harmonization (ICH) guidelines. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Maia, Priscila M. S.; de F. Rezende, Flavia B.; Netto, Annibal D. Pereira; de C. Marques, Flávia F.
The doramectin (DOR), which belongs to the avermectins group (AVM), has a high antiparasitic activity and so it has been widely used in food-producing animals. The DOR shows low fluorescence quantum efficiency and as a consequence, chemical derivatization reactions are necessary to produce derivatives with improved luminescent properties before its determination by fluorimetry. As the presence of this compound in food represents a risk to human health, an easy, clean and low cost derivatization reaction, which is alternative to those usually employed and that enables its spectrofluorimetric determination in milk samples, was developed. Ethanolic solutions of DOR, containing sodium hydroxide at a final concentration of 0.25 mol L-1, after 60 min of heating at 50 °C, produced fluorescent signals 1000 times higher than the original ethanolic solution. Using these optimized conditions, a linear response range that extended from 50.00 to 1000 μg L-1, with a value of (R2) equal to 0.9970, was obtained. Average recovery of DOR was 92.5 ± 1.5% (n = 3) in bovine milk fortified samples submitted to a liquid-liquid extraction at low temperature and pre concentration process, indicating the usefulness and effectiveness of the proposed method. The proposed spectrofluorimetric method is an alternative to high-performance liquid chromatography (HPLC) based methods, allowing rapid and simple detection of doramectin in milk samples.
Khan, Muhammad Naeem; Shah, Jasmin; Jan, Muhammad Rasul; Lee, Sang Hak
2013-01-01
A simple, sensitive, and accurate spectrofluorimetric method was developed for the determination of citalopram in bulk and pharmaceutical preparations. The method is based on the enhancement of the weak fluorescence signal (FL) of the Tb (III)-citalopram system in the presence of silver nanoparticles. Fluorescence intensities were measured at 555 nm after excitation at 281 nm. Prepared silver nanoparticles (AgNPs) were characterized by UV-Visible spectra and transmission electron microscopy (TEM). Various factors affecting the formation of citalopram-Tb (III)-AgNPs complexes were studied and optimized. The fluorescence intensity versus concentration plot was linear over the range 0.02-14 μg mL(-1), with an excellent correlation coefficient of 0.9978. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 7.15 × 10(-6) μg mL(-1) and 2.38 × 10(-5) μg mL(-1) respectively. The proposed method was found to have good reproducibility with a relative standard deviation of 3.66% (n = 6). The interference effects of common excipients found in pharmaceutical preparations were studied. The developed method was validated statistically by performing recoveries studies and successfully applied for the assay of citalopram in bulk powder and pharmaceutical preparations. Percent recoveries were found to range from 98.98% to 100.97% for bulk powder and from 96.57% to 101.77% for pharmaceutical preparations.
Ragab, Marwa A A; Galal, Shereen M; Korany, Mohamed A; Ahmed, Aya R
2017-12-01
LCZ696 (sacubitril/valsartan, Entresto™) is a therapy lately approved by United States Food and Drug Administration (US FDA) as a heart failure therapy. It is claimed to decrease the mortality rate and hospitalization for patients with chronic heart failure. This study is considered as the first report to investigate the fluorimetric behavior of sacubitril in addition to pursuing all the different conditions that may affect its fluorescence. Various conditions were studied, for example studying the effects of organized media, solvents and pH, which may affect the fluorescence behavior of sacubitril. For the simultaneous determination of the newly approved supramolecular complex of valsartan (VAL) and sacubitril (SAC) in their tablets, a sensitive and simple first derivative spectrofluorimetric method was developed. The method involved the measurement of native fluorescence at 416 nm and 314 nm (λ ex 249 nm) for VAL and SAC, respectively. The first (D1) derivative technique was applied to the emission data to resolve a partial overlap that appeared in their emission spectra. The proposed method was successfully applied for the assay of the two drugs in their supramolecular complex LCZ696 with no interference from common pharmaceutical additives. International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines were followed in order to validate the proposed method. Copyright © 2017 John Wiley & Sons, Ltd.
Maher, H M; Alzoman, N Z; Shehata, S M
2017-03-01
A new rapid and simple stability-indicating spectrofluorimetric method has been developed for the determination of two irreversible tyrosine kinase inhibitors (TKIs), neratinib (NER) and pelitinib (PEL). The method is based upon measurement of the native fluorescence intensity of both drugs at λ ex 270 nm in aqueous borate buffer solutions (pH 10.5). The fluorescence intensity recorded at 545 nm (NER) and 465 nm (PEL) were rectilinear over the concentration range of 0.1-10 μg/mL for both drugs with a high correlation coefficient (r > 0.999). The proposed method provided low limits of detection and of quantitation of 0.07, 0.11 μg/mL (NER) and 0.02, 0.05 μg/mL (PEL), respectively. The method was successfully applied for the determination of NER and PEL in bulk powder. The proposed methods were fully validated as per the International Conference on Harmonisation (ICH) guidelines. The application of the method was extended to stability studies of both NER and PEL under different forced-degradation conditions (acidic-induced, base-induced, oxidative, wet heat, and photolytic degradation). Moreover, the kinetics of the base-induced and oxidative degradation of both drugs was investigated and the pseudo-first-order rate constants and half-lives were estimated at different temperatures. Also, an Arrhenius plot was applied to predict the stability behaviour of the two drugs at room temperature. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Maher, Hadir M; Ragab, Marwa A A; El-Kimary, Eman I
2015-01-01
Methotrexate (MTX) is widely used to treat rheumatoid arthritis (RA), mostly along with non-steroidal anti-inflammatory drugs (NSAIDs), the most common of which is aspirin or acetyl salicylic acid (ASA). Since NSAIDs impair MTX clearance and increase its toxicity, it was necessary to develop a simple and reliable method for the monitoring of MTX levels in urine samples, when coadministered with ASA. The method was based on the spectrofluorimetric measurement of the acid-induced hydrolysis product of MTX, 4-amino-4-deoxy-10-methylpteroic acid (AMP), along with the strongly fluorescent salicylic acid (SA), a product of acid-induced hydrolysis of aspirin and its metabolites in urine. The overlapping emission spectra were resolved using the derivative method (D method). In addition, the corresponding derivative emission spectra were convoluted using discrete Fourier functions, 8-points sin xi polynomials, (D/FF method) for better elimination of interferences. Validation of the developed methods was carried out according to the ICH guidelines. Moreover, the data obtained using derivative and convoluted derivative spectra were treated using the non-parametric Theil's method (NP), compared with the least-squares parametric regression method (LSP). The results treated with Theil's method were more accurate and precise compared with LSP since the former is less affected by the outliers. This work offers the potential of both derivative and convolution using discrete Fourier functions in addition to the effectiveness of using the NP regression analysis of data. The high sensitivity obtained by the proposed methods was promising for measuring low concentration levels of the two drugs in urine samples. These methods were efficiently used to measure the drugs in human urine samples following their co-administration.
Ulu, Sevgi Tatar
2009-09-01
A sensitive, simple and selective spectrofluorimetric method was developed for the determination of lomefloxacin in biological fluids and pharmaceutical preparations. The method is based on the reaction between the drug and 4-chloro-7-nitrobenzodioxazole in borate buffer of pH 8.5 to yield a highly fluorescent derivative that is measured at 533 nm after excitation at 433 nm. The calibration curves were linear over the concentration ranges of 12.5-625, 15-1500 and 20-2000 ng/mL for plasma, urine and standard solution, respectively. The limits of detection were 4.0 ng/mL in plasma, 5.0 ng/mL in urine and 7.0 ng/mL in standard solution. The intra-assay accuracy and precision in plasma ranged from 0.032 to 2.40% and 0.23 to 0.36%, respectively, while inter-assay accuracy and precision ranged from 0.45 to 2.10% and 0.25 to 0.38%, respectively. The intra-assay accuracy and precision estimated on spiked samples in urine ranged from 1.27 to 4.20% and 0.12 to 0.24%, respectively, while inter-assay accuracy and precision ranged from 1.60 to 4.00% and 0.14 to 0.25%, respectively. The mean recovery of lomefloxacin from plasma and urine was 98.34 and 98.43%, respectively. The method was successfully applied to the determination of lomefloxacin in pharmaceuticals and biological fluids.
Xu, Zhicheng; Yang, Weibing; Dong, Chuan
2005-09-15
A new intramolecular charge transfer fluorescence probe, namely, 4'-dimethylamino-2,5-dihydroxychalcone (DMADHC), exhibited dramatic enhancement of fluorescence intensity with an accompanying blue shift of the emission maximum when the concentration of human serum albumin (HSA) was increased. Binding to HSA also caused a progressive shift in the absorption spectrum of DMADHC, and a clear isosbestic point appeared. The binding site number and binding constant were calculated. Thermodynamic parameters were given and possible binding site was speculated. The optimum conditions for the determination of HSA were also investigated. A new, fast, and simple spectrofluorimetric method for the determination of HSA was developed. In the detection of HSA in samples of human plasma, this method gave values close to that of the Erythrosin B method.
Taha, Elham Anwer; Salama, Nahla Nour; Fattah, Laila El-Sayed Abdel
2006-05-01
Two sensitive and selective spectrofluorimetric and spectrophotometric stability-indicating methods have been developed for the determination of some non-steroidal anti-inflammatory oxicam derivatives namely lornoxicam (Lx), tenoxicam (Tx) and meloxicam (Mx) after their complete alkaline hydrolysis. The methods are based on derivatization of alkaline hydrolytic products with 7-chloro-4-nitrobenz-2-oxa-1,3-diazole (NBD-Cl). The products showed an absorption maximum at 460 nm for the three studied drugs and fluorescence emission peak at 535 nm in methanol. The color was stable for at least 48 h. The optimum conditions of the reaction were investigated and it was found that the reaction proceeds quantitatively at pH 8, after heating in a boiling water bath for 30 min. The methods were found to be linear in the ranges of 1-10 microg ml(-1) for Lx and Tx and 0.5-4.0 microg ml(-1) for Mx for spectrophotometric method, while 0.05-1.0 microg ml(-1) for Lx and Tx and 0.025-0.4 microg ml(-1) for Mx for the spectrofluorimetric method. The validity of the methods was assessed according to USP guidelines. Statistical analysis of the results revealed high accuracy and good precision. The suggested procedures could be used for the determination of the above mentioned drugs in pure and dosage forms as well as in the presence of their degradation products.
Spectrofluorimetric determination of cefixime using terbium-danofloxacin probe
Manzoori, Jamshid L.; Amjadi, Mohammad; Soltani, Naser; Jouyban, Abolghasem
2014-01-01
Objective(s): Cefixime (Cfx), is a semi-synthetic third-generation oral cephalosporin antibiotic that is prescribed for the treatment of susceptible infections. There are some procedures for the determination of Cfx in pharmaceutical formulations and biological samples. Herein a spectrofluorimetric method was proposed for Cfx determination based on the fluorescence quenching of terbium-danofloxacin (Tb3+-Dano) in the presence of Cfx. Materials and Methods: Cfx was detected based on fluorescence quenching of terbium-danofloxacin (Tb3+-Dano) in the presence of Cfx with maximum excitation and emission wavelengths at 347 nm and 545 nm, respectively. The quenched fluorescence intensity of Tb3+- Dano system is proportional to the concentration of Cfx. The optimum conditions for the determination of Cfx were studied. Results: The maximum response was achieved under optimum conditions of [Tris buffer]= 0.008 mol/l (pH 6.5), [Tb3+]=1×10-4 mol/l and [Dano]=1×10-4 mol/l. The developed method was evaluated in terms of accuracy, precision and limit of detection. The linear concentration ranges for quantification of Cfx were 8.8×10-8-8.8×10-7 mol/l and 1.1×10-7-8.8×10-7 mol/l in standard and human serum samples with the detection limits (S/N=3) of 2.8×10-8 mol/l and 3.9×10-8 mol/l, respectively. The Cfx was determined in pharmaceutical tablets and spiked serum samples and the results were satisfactory. Conclusion: This method is simple, practical and relatively interference-free for determination of Cfx in pharmaceutical tablets and serum samples. PMID:24904718
Dai, Gang; Aodeng, Gao-wa
2004-07-01
A new spectrofluorimetric method for the determination of trace amount of Fe(III) has been developed. This method is based on the fluorescence quenching of 2,4-dichro-phenylfluorone due to the formation of complex Fe(III)-DCIPF. In pH 5.2-5.9 buffer solution, Fe (III) and DCIPF react on each other to form a red complex. Its composition was established by method of continuous variations and molar-ratio as Fe(III): DCIPF = 1:4, the excitation and emission wavelengths were found to be 282 and 560 nm, respectively. There is a linear relationship in the range 4-24 ng x mL(-1) for Fe(III). This method is simple and rapid, and has been applied to the determination of trace iron in Chinese herbal medicine and tea samples with satisfactory results.
NASA Astrophysics Data System (ADS)
Manzoori, Jamshid L.; Amjadi, Mohammad
2003-03-01
The characteristics of host-guest complexation between β-cyclodextrin (β-CD) and two forms of ibuprofen (protonated and deprotonated) were investigated by fluorescence spectrometry. 1:1 stoichiometries for both complexes were established and their association constants at different temperatures were calculated by applying a non-linear regression method to the change in the fluorescence of ibuprofen that brought about by the presence of β-CD. The thermodynamic parameters (Δ H, Δ S and Δ G) associated with the inclusion process were also determined. Based on the obtained results, a sensitive spectrofluorimetric method for the determination of ibuprofen was developed with a linear range of 0.1-2 μg ml -1 and a detection limit of 0.03 μg ml -1. The method was applied satisfactorily to the determination of ibuprofen in pharmaceutical preparations.
NASA Astrophysics Data System (ADS)
El-ghobashy, Mohamed R.; Yehia, Ali M.; Helmy, Aya H.; Youssef, Nadia F.
2018-01-01
Simple, smart and sensitive normal fluorescence and stability-indicating derivative synchronous spectrofluorimetric methods have been developed and validated for the determination of gliquidone in the drug substance and drug product. Normal spectrofluorimetric method of gliquidone was established in methanol at λ excitation 225 nm and λ emission 400 nm in concentration range 0.2-3 μg/ml with LOD equal 0.028. The fluorescence quantum yield of gliquidone was calculated using quinine sulfate as a reference and found to be 0.542. Stability-indicating first and third derivative synchronous fluorescence spectroscopy were successfully utilized to overcome the overlapped spectra in normal fluorescence of gliquidone and its alkaline degradation product. Derivative synchronous methods are based on using the synchronous fluorescence of gliquidone and its degradation product in methanol at Δ λ50 nm. Peak amplitude in the first derivative of synchronous fluorescence spectra was measured at 309 nm where degradation product showed zero-crossing without interference. The peak amplitudes in the third derivative of synchronous fluorescence spectra, peak to trough were measured at 316,329 nm where degradation product showed zero-crossing. The different experimental parameters affecting the normal and synchronous fluorescence intensity of gliquidone were studied and optimized. Moreover, the cited methods have been validated as per ICH guidelines. The peak amplitude-concentration plots of the derivative synchronous fluorescence were linear over the concentration range 0.05-2 μg/ml for gliquidone. Limits of detection were 0.020 and 0.022 in first and third derivative synchronous spectra, respectively. The adopted methods were successfully applied to commercial tablets and the results demonstrated that the derivative synchronous fluorescence spectroscopy is a powerful stability-indicating method, suitable for routine use with a short analysis time. Statistical comparison between the results obtained by normal fluorescence and derivative synchronous methods and the official one using student's t-test and F-ratio showed no significant difference regarding accuracy and precision.
Karasakal, A; Ulu, S T
2014-05-01
A novel, sensitive and selective spectrofluorimetric method was developed for the determination of tamsulosin in spiked human urine and pharmaceutical preparations. The proposed method is based on the reaction of tamsulosin with 1-dimethylaminonaphthalene-5-sulfonyl chloride in carbonate buffer pH 10.5 to yield a highly fluorescent derivative. The described method was validated and the analytical parameters of linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, recovery and robustness were evaluated. The proposed method showed a linear dependence of the fluorescence intensity on drug concentration over the range 1.22 × 10(-7) to 7.35 × 10(-6) M. LOD and LOQ were calculated as 1.07 × 10(-7) and 3.23 × 10(-7) M, respectively. The proposed method was successfully applied for the determination of tamsulosin in pharmaceutical preparations and the obtained results were in good agreement with those obtained using the reference method. Copyright © 2013 John Wiley & Sons, Ltd.
Analysis of quetiapine in human plasma using fluorescence spectroscopy
NASA Astrophysics Data System (ADS)
Mostafa, Islam M.; Omar, Mahmoud A.; Nagy, Dalia M.; Derayea, Sayed M.
2018-05-01
A simple and sensitive spectrofluorimetric method has been development for the assurance of quetiapine fumarate (QTF). The proposed method was utilized for measuring the fluorescence intensity of the yellow fluorescent product at 510 nm (λex 470 nm). The fluorescent product has resulted from the nucleophilic substitution reaction of QTF with 4-chloro-7-nitrobenzofurazane (NBD-Cl) in Mcllvaine buffer (pH 7.0). The diverse variables influencing the development of the reaction product were deliberately changed and optimized. The linear concentration range of the proposed method was of 0.2-2.0 μg ml-1.The limits of detection and quantitation were 0.05 and 0.17 μg ml-1, respectively. The proposed method was applied for the assurance of QTF in its tablets without interference from basic excipients. In addition, the proposed method was used for in vitro analysis of the QTF in spiked human plasma, the percent mean recovery was (n = 3) 98.82 ± 1.484%.
Manzoori, Jamshid L; Amjadi, Mohammad
2003-03-15
The characteristics of host-guest complexation between beta-cyclodextrin (beta-CD) and two forms of ibuprofen (protonated and deprotonated) were investigated by fluorescence spectrometry. 1:1 stoichiometries for both complexes were established and their association constants at different temperatures were calculated by applying a non-linear regression method to the change in the fluorescence of ibuprofen that brought about by the presence of beta-CD. The thermodynamic parameters (deltaH, deltaS and deltaG) associated with the inclusion process were also determined. Based on the obtained results, a sensitive spectrofluorimetric method for the determination of ibuprofen was developed with a linear range of 0.1-2 microg ml(-1) and a detection limit of 0.03 microg ml(-1). The method was applied satisfactorily to the determination of ibuprofen in pharmaceutical preparations. Copyright 2002 Elsevier Science B.V.
Lotfi, Ali; Manzoori, Jamshid L
2016-11-01
In this study, a simple and sensitive spectrofluorimetric method is presented for the determination of fluoxetine based on the enhancing effect of silver nanoparticles (AgNPs) on the terbium-fluoxetine fluorescence emission. The AgNPs were prepared by a simple reduction method and characterized by UV-Vis spectroscopy and transmission electron microscopy. It was indicated that these AgNPs have a remarkable amplifying effect on the terbium-sensitized fluorescence of fluoxetine. The effects of various parameters such as AgNP and Tb 3+ concentration and the pH of the media were investigated. Under obtained optimal conditions, the fluorescence intensity of the terbium-fluoxetine-AgNP system was enhanced linearly by increasing the concentration of fluoxetine in the range of 0.008 to 19 mg/L. The limit of detection (b + 3s) was 8.3 × 10 -4 mg/L. The interference effects of common species found in real samples were also studied. The method had good linearity, recovery, reproducibility and sensitivity, and was satisfactorily applied for the determination of fluoxetine in tablet formulations, human urine and plasma samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
El-Didamony, Akram M; Gouda, Ayman A
2011-01-01
A new highly sensitive and specific spectrofluorimetric method has been developed to determine a sympathomimetic drug pseudoephedrine hydrochloride. The present method was based on derivatization with 4-chloro-7-nitrobenzofurazan in phosphate buffer at pH 7.8 to produce a highly fluorescent product which was measured at 532 nm (excitation at 475 nm). Under the optimized conditions a linear relationship and good correlation was found between the fluorescence intensity and pseudoephedrine hydrochloride concentration in the range of 0.5-5 µg mL(-1). The proposed method was successfully applied to the assay of pseudoephedrine hydrochloride in commercial pharmaceutical formulations with good accuracy and precision and without interferences from common additives. Statistical comparison of the results with a well-established method showed excellent agreement and proved that there was no significant difference in the accuracy and precision. The stoichiometry of the reaction was determined and the reaction pathway was postulated. Copyright © 2010 John Wiley & Sons, Ltd.
Rodrigues, Máira Regina
2012-02-01
A spectrofluorimetric method for the determination of D,L-N-methyl-3-phenyl-3-[(α,α,α-trifluoro-p-tolyl)oxy]propylamine, fluoxetine (F), in pharmaceuticals was evaluated in the 50.0-500.0 μg ml⁻¹ range. Linearity, sensibility, quantification and detection limit, and precision values are satisfactory. The method does not need pre-treatment and was successfully applied to the determination in pharmaceuticals and chitosan (Ch) solution. Ch has an ability to carry and absorb fat and may eventually be used together with F in slimming diets, and then interactions of Ch-F may occur. This work seeks to study these interactions by monitoring the photophysics of a drug in the presence of Ch. The results warn about the care that must be taken when both compounds are prescribed together.
NASA Astrophysics Data System (ADS)
Trivedi, J.; Variya, B.; Gandhi, H.; Rathod, S. P.
2016-01-01
Curcumin is a medicinally important phytoconstituent of curcuminoids. The present study describes development of a simple method for estimation of curcumin in rat plasma. This method involves the use of spectrofluorimetry for evaluation of curcumin at 257 (Ex) and 504 nm (Em). Sample preparation involves only two steps: extraction of curcumin and drying the extract. Following this procedure, the samples are reconstituted with ethyl acetate, and relative fluorescence intensity is measured using a spectrofluorimeter. The method was validated as per CDER guidelines. The linearity of the method was found to be in the range of 100-500 ng/mL with accuracy and precision lying within 2% RSD. The LOD and LOQ were found to be 15.3 and 46.1 ng/mL, respectively. The method was applied for pharmacokinetic evaluation in rats, and AUC, Cmax, and Tmax were found to be 5580 ± 1006 h × ng/mL, 1526 ± 209 ng/mL, and 2.97 ± 0.28 h, respectively, with a plasma half-life of 1.14 ± 0.27 h.
Ulu, Sevgi Tatar
2012-01-01
A sensitive spectrofluorimetric method was developed for the determination of tizanidine in human plasma, urine and pharmaceutical preparations. The method is based on reaction of tizanidine with 1-dimethylaminonaphthalene-5-sulphonyl chloride (dansyl chloride) in an alkaline medium to form a highly fluorescent derivative that was measured at 511 nm after excitation at 383 nm. The different experimental parameters affecting the fluorescence intensity of tizanidine was carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges 50-500 and 20-300 ng/mL for plasma and urine, respectively, detection limits of 1.81 and 0.54 ng/mL and quantification limits of 5.43 and 1.62 ng/mL for plasma and urine, respectively. The method presents good performance in terms of linearity, detection and quantification limits, precision, accuracy and specificity. The proposed method was successfully applied for the determination of tizanidine in pharmaceutical preparations. The results obtained were compared with a reference method, using t- and F-tests. Copyright © 2011 John Wiley & Sons, Ltd.
Hergert, L A; Escandar, G M
2003-06-13
The inclusion complexation of ibuprofen in beta-cyclodextrin (beta-CD) has been examined by means of spectrofluorimetry at both acid and alkaline pH. The results suggest that stable 1:1 complexes are formed in both media. The analysis of the pK(a) values for ibuprofen in both the absence and presence of beta-CD (4.12 and 4.66, respectively) suggests that in the inclusion complex the carboxylic group is located outside the cyclodextrin (CD) but interacting with it. Further structural characterization of the complex was carried out by means of am1 semiempiral calculations. Based on the obtained results, a spectrofluorimetric method for the determination of ibuprofen in the presence of beta-CD at 10 degrees C was developed in the range of 4.7-58 mug ml(-1). Better limits of detection (1.6 mug ml(-1)) and quantification (4.7 mug ml(-1)) were obtained in this latter case with respect to those obtained in the absence of beta-CD. The method was satisfactorily applied to the quantification of ibuprofen in pharmaceutical preparations. A novel spectrofluorimetric determination of ibuprofen in the presence of beta-CD was also developed for serum samples at concentration levels between 5 and 70 mug ml(-1). It uses second-order fluorescence excitation-emission matrices coupled to an algorithm based on self-weighted alternating trilinear decomposition (SWATLD), and avoids resorting to separative instrumental analyses.
Sabry, Suzy M; Abdel-Hady, M; Elsayed, M; Fahmy, Osama T; Maher, Hadir M
2003-07-14
Study of the degradation reaction of methotrexate (MTX) in acidic solution was carried out. Optimization of the experimental parameters of MTX acid hydrolysis was investigated. Spectrofluorimetric method for determination of MTX through measurement of its acid-degradation product, 4-amino-4-deoxy-10-methylpteroic acid (AMP), was developed. Stability of the standard solution of MTX prepared in sulfuric acid was discussed in the view of accelerated stability analysis. Two other comparative spectroflourimetric methods based on measuring the fluorescence intensities from either a condensation reaction with acetylacetone-formaldehyde (Hantzsch reaction) or a reaction with fluorescamine were also described. Beer's law validation, accuracy, precision, limits of detection, limits of quantification, and other aspects of analytical merit are presented in the text. The proposed methods were successfully applied for the analysis of MTX in pure drug and tablets dosage form. The sensitivity of the developed methods was favorable, so it was possible to be adopted for determination of MTX in plasma samples for routine use in high-dose MTX therapy.
NASA Astrophysics Data System (ADS)
Hou, Faju; Miao, Yanhong; Jiang, Chongqiu
2005-10-01
A new spectrofluorimetric method was developed for determination of adenosine disodium triphosphate (ATP). We studied the interactions between oxytetracycline (OTC)-Eu 3+ complex and adenosine disodium triphosphate (ATP) by using UV-vis absorption and fluorescence spectra. Using oxytetracycline (OTC)-Eu 3+ as a fluorescence probe, under the optimum conditions, ATP can remarkably enhance the fluorescence intensity of the OTC-Eu 3+ complex at λ = 612 nm and the enhanced fluorescence intensity of Eu 3+ ion is in proportion to the concentration of ATP. Optimum conditions for the determination of ATP were also investigated. The linear ranges for ATP are 8.00 × 10 -8-1.50 × 10 -6 mol L -1 with detection limits of 2.67 × 10 -9 mol L -1. This method is simple, practical and relatively free interference from coexisting substances and can be successfully applied to determination of ATP in samples. The mechanism of fluorescence enhancement between oxytetracycline (OTC)-Eu 3+ complex and ATP was also studied.
Derayea, Sayed M; Badr El-Din, Khalid M; Mohammed, Fatma F
2017-12-01
A novel sensitive and cost-effective spectrofluorimetric method has been developed and validated for determination of lisinopril (an angiotensin converting enzyme inhibitor) in its pure form and pharmaceutical preparations. The method is based on the reaction of the drug with ninhydrin and phenylacetaldehyde in buffered medium (pH 7.0) to form a highly fluorescent product measured at 460 nm after excitation at 390 nm. Different experimental parameters were optimized and calibration curve was constructed. The fluorescence-concentration relationship was linear in the range of 0.15-4.0 μg mL -1 . The calculated Limit of detection (LOD) and Limit of quantitation (LOQ) were 0.04 and 0.12 μg mL -1 , respectively. The method was successfully applied for the analysis of pharmaceutical preparations containing the studied drug either alone or co-formulated with hydrochlorothiazide. The obtained results were in agreement with those of the reported method in respect to accuracy and precession. Moreover, the method was applied content uniformity testing according to United States Pharmacopeia (USP) guidelines. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Youssef, A. O.
2018-04-01
A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.
NASA Astrophysics Data System (ADS)
Omar, Mahmoud A.; Mohamed, Abdel-Maaboud I.; Derayea, Sayed M.; Hammad, Mohamed A.; Mohamed, Abobakr A.
2018-04-01
A new, selective and sensitive spectrofluorimetric method was designed for the quantitation of doxazosin (DOX), terazosin (TER) and alfuzosin (ALF) in their dosage forms and human plasma. The method adopts efficient derivatization of the studied drugs with ortho-phthalaldehyde (OPA), in the presence of 2-mercaptoethanol in borate buffer (pH 9.7) to generate a highly fluorescent isoindole derivatives, which can strongly enhance the fluorescence intensities of the studied drugs, allowing their sensitive determination at 430 nm after excitation at 337 nm. The fluorescence-concentration plots were rectilinear over the ranges (10.0-400.0) ng/mL. Detection and quantification limits were found to be (0.52-3.88) and (1.59-11.76) ng/mL, respectively. The proposed method was validated according to ICH guidelines, and successfully applied for the determination of pharmaceutical preparations of the studied drugs. Moreover, the high sensitivity of the proposed method permits its successful application to the analysis of the studied drugs in spiked human plasma with % recovery (96.12 ± 1.34-100.66 ± 0.57, n = 3). A proposal for the reaction mechanism was presented.
NASA Astrophysics Data System (ADS)
Derayea, Sayed M.; Badr El-din, Khalid M.; Mohammed, Fatma F.
2018-01-01
A new sensitive and discriminating spectrofluorimetric method has been developed and validated for determination of Lisinopril, one of the angiotensin converting enzyme inhibitors, in its pure bulk form and pharmaceutical tablets. The reaction of Lisinopril with ethylacetoacetate and formaldehyde in acidic buffered medium (pH 3.8) has yielded a pale yellow product that exhibited a high fluorescence measured at 438 nm after excitation at 350 nm. All the experimental parameters affecting the formation and stability of the produced fluorophore were carefully investigated and optimized to give the maximum sensitivity. The fluorescence intensity was directly proportional to the drug concentration in the range of 0.5-4.5 μg/mL with a limit of detection equal to 0.16 μg/mL. The method was successfully applied in the analysis of the commercially available pharmaceutical tablets containing the single drug or its binary mixtures with Hydrochlorothiazide. Furthermore, the developed procedure was adapted for studying the content uniformity test of some dosage forms containing the cited drug.
Derayea, Sayed M; Ahmed, Hytham M; Abdelmageed, Osama H; Haredy, Ahmed M
2016-01-15
A new validated spectrofluorimetric method has been developed for the determination of some cephalosporins namely; cefepime, cefaclor, cefadroxil, cefpodoxime and cefexime. The method was based on the reaction of these drugs with safranin in slightly alkaline medium (pH 8.0), to form ion-association complexes. The fluorescent products were extracted into chloroform and their fluorescence intensities were measured at 544-565 nm after excitation at 518-524 nm. The reaction conditions influencing the product formation and stability were investigated and optimized. The relative fluorescence intensity was proportional to the drug concentration in the linear ranges of 0.15-1.35, 0.35-1.25, 0.35-1.25, 0.20-1.44 and 0.20-1.25 μg/mL for cefepime, cefaclor, cefadroxil, cefpodoxime proxetil and cefexime, respectively. The detection limits were 40, 100, 100, 60 and 70 ng/mL, respectively. The performance of the developed method was evaluated in terms of Student's t-test and variance ratio F-test to find out the significance of proposed methods over the reference spectrophotometric method. Various pharmaceutical formulations were successfully analyzed using the proposed method and the results were in good agreement with those of the previously reported methods. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Derayea, Sayed M.; Ahmed, Hytham M.; Abdelmageed, Osama H.; Haredy, Ahmed M.
2016-01-01
A new validated spectrofluorimetric method has been developed for the determination of some cephalosporins namely; cefepime, cefaclor, cefadroxil, cefpodoxime and cefexime. The method was based on the reaction of these drugs with safranin in slightly alkaline medium (pH 8.0), to form ion-association complexes. The fluorescent products were extracted into chloroform and their fluorescence intensities were measured at 544-565 nm after excitation at 518-524 nm. The reaction conditions influencing the product formation and stability were investigated and optimized. The relative fluorescence intensity was proportional to the drug concentration in the linear ranges of 0.15-1.35, 0.35-1.25, 0.35-1.25, 0.20-1.44 and 0.20-1.25 μg/mL for cefepime, cefaclor, cefadroxil, cefpodoxime proxetil and cefexime, respectively. The detection limits were 40, 100, 100, 60 and 70 ng/mL, respectively. The performance of the developed method was evaluated in terms of Student's t-test and variance ratio F-test to find out the significance of proposed methods over the reference spectrophotometric method. Various pharmaceutical formulations were successfully analyzed using the proposed method and the results were in good agreement with those of the previously reported methods.
NASA Astrophysics Data System (ADS)
Moussa, B. A.; Mohamed, M. F.; Youssef, N. F.
2011-01-01
Two stability-indicating spectrofluorimetric methods have been developed for the determination of ezetimibe and olmesartan medoxomil, drugs affecting the cardiovascular system, and validated in the presence of their degradation products. The first method, for ezetimibe, is based on an oxidative coupling reaction of ezetimibe with 3-methylbenzothiazolin-2-one hydrazone hydrochloride in the presence of cerium (IV) ammonium sulfate in an acidic medium. The quenching effect of ezetimibe on the fluorescence of excess cerous ions is measured at the emission wavelength, λem, of 345 nm with the excitation wavelength, λex, of 296 nm. Factors affecting the reaction were carefully studied and optimized. The second method, for olmesartan medoxomil, is based on measuring the native fluorescence intensity of olmesartan medoxomil in methanol at λem = 360 nm with λex = 286 nm. Regression plots revealed good linear relationships in the assay limits of 10-120 and 8-112 g/ml for ezetimibe and olmesartan medoxomil, respectively. The validity of the methods was assessed according to the United States Pharmacopeya guidelines. Statistical analysis of the results exposed good Student's t-test and F-ratio values. The introduced methods were successfully applied to the analysis of ezetimibe and olmesartan medoxomil in drug substances and drug products as well as in the presence of their degradation products.
Elkhoudary, Mahmoud M; Naguib, Ibrahim A; Abdel Salam, Randa A; Hadad, Ghada M
2017-05-01
Four accurate, sensitive and reliable stability indicating chemometric methods were developed for the quantitative determination of Agomelatine (AGM) whether in pure form or in pharmaceutical formulations. Two supervised learning machines' methods; linear artificial neural networks (PC-linANN) preceded by principle component analysis and linear support vector regression (linSVR), were compared with two principle component based methods; principle component regression (PCR) as well as partial least squares (PLS) for the spectrofluorimetric determination of AGM and its degradants. The results showed the benefits behind using linear learning machines' methods and the inherent merits of their algorithms in handling overlapped noisy spectral data especially during the challenging determination of AGM alkaline and acidic degradants (DG1 and DG2). Relative mean squared error of prediction (RMSEP) for the proposed models in the determination of AGM were 1.68, 1.72, 0.68 and 0.22 for PCR, PLS, SVR and PC-linANN; respectively. The results showed the superiority of supervised learning machines' methods over principle component based methods. Besides, the results suggested that linANN is the method of choice for determination of components in low amounts with similar overlapped spectra and narrow linearity range. Comparison between the proposed chemometric models and a reported HPLC method revealed the comparable performance and quantification power of the proposed models.
NASA Astrophysics Data System (ADS)
Zhou, Yunyou; Xu, Hongwei; Wu, Lian; Liu, Chun; Lu, Qin; Wang, Lun
2008-11-01
The characteristics of host-guest complexation between p-( p-sulfonated benzeneazo) calix[6]arene (SBC6A) and vitamin K 3 (VK 3) were investigated by fluorescence spectrometry. A 1:1 stoichiometry for the complexation was established and was verified by Job's plot. An association constant of 4.95 × 10 3 L mol -1 at 20 °C was calculated by applying a deduced equation. The interaction mechanism of the inclusion complex was discussed. It was found that the fluorescence of SBC6A could be remarkably quenched by an appropriate amount of VK 3 especially when non-ionic surfactant Triton X-100 existed. According to the obtained results, a novel sensitive spectrofluorimetric method for the determination of VK 3 based on supramolecular complex was developed with a linear range of 5.0 × 10 -7-3.0 × 10 -5 mol L -1 and a detection limit of 2.0 × 10 -7 mol L -1. The proposed method was used to determine VK 3 in commercial preparations with satisfactory results.
Zhou, Yunyou; Xu, Hongwei; Wu, Lian; Liu, Chun; Lu, Qin; Wang, Lun
2008-11-15
The characteristics of host-guest complexation between p-(p-sulfonated benzeneazo) calix[6]arene (SBC6A) and vitamin K3 (VK3) were investigated by fluorescence spectrometry. A 1:1 stoichiometry for the complexation was established and was verified by Job's plot. An association constant of 4.95 x 10(3)L mol(-1) at 20 degrees C was calculated by applying a deduced equation. The interaction mechanism of the inclusion complex was discussed. It was found that the fluorescence of SBC6A could be remarkably quenched by an appropriate amount of VK3 especially when non-ionic surfactant Triton X-100 existed. According to the obtained results, a novel sensitive spectrofluorimetric method for the determination of VK3 based on supramolecular complex was developed with a linear range of 5.0 x 10(-7) -3.0 x 10(-5)mol L(-1) and a detection limit of 2.0 x 10(-7)mol L(-1). The proposed method was used to determine VK3 in commercial preparations with satisfactory results.
Attia, Tamer Z; Omar, Mahmoud A
2016-08-01
A reliable, sensitive, cheap and non-extractive spectrofluorimetric method has been developed and validated for determination of thioridazine and flupentixol based on ternary complex formation with eosin and lead(II) in the presence of methylcellulose as surfactant at pH 3.2. Under the optimum conditions, the quantitative quenching effect of investigated drugs on the native fluorescence of eosin has been investigated. The quenching of the eosin fluorescence was measured at 517 nm after excitation at 462 nm. The different experimental parameters affecting the development and stability of the reaction products were carefully studied and optimized, and the results were satisfactory. The calibration plots were constructed over the range of 0.5-3.0 µg mL(-1) . The developed method was successfully applied for determination of investigated drugs in commercial tablets without interference from common excipients. It was further applied for content uniformity testing of flupentixol in its tablets. Statistical comparisons of the results with those of the reference methods revealed excellent agreement and indicated no significant difference in accuracy and precision. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
[Determination of benzo(alpha)pyrene in food with microwave-assisted extraction].
Zhou, Na; Luo, He-Dong; Li, Na; Li, Yao-Qun
2014-03-01
Coupling derivative technique and constant-energy synchronous fluorescence scanning technique, a method of determining benzo[alpha] pyrene in foods by second derivative constant-energy synchronous spectrofluorimetry after microwave-assisted treatment of samples was established using domestic microwave oven. The main factors of influencing the efficiency of microwave extraction were discussed, including the extraction solvent types and amounts, the microwave extraction time, microwave radiation power and cooling time. And the comparison with ultrasonic extraction was made. Low-fat food samples, which were just microwave-extracted with mixed-solvents, could be analyzed immediately by the spectrofluorimetric technique. For high-fat food samples, microwave-assisted saponification and extraction were made at the same time, thus simplifying operation steps and reducing sample analysis time. So the whole sample analysis process could be completed within one hour. This method was simple, rapid and inexpensive. In consequence, it was applied to determine benzo(a)pyrene in food with good reproducibility and the recoveries of benzo(alpha) pyrene ranged from 90.0% to 105.0% for the low fat samples and 83.3% to 94.6% for high-fat samples.
Abu El-Enin, Mohammed Abu Bakr; Al-Ghaffar Hammouda, Mohammed El-Sayed Abd; El-Sherbiny, Dina Tawfik; El-Wasseef, Dalia Rashad; El-Ashry, Saadia Mahmoud
2016-02-01
A valid, sensitive and rapid spectrofluorimetric method has been developed and validated for determination of both tadalafil (TAD) and vardenafil (VAR) either in their pure form, in their tablet dosage forms or spiked in human plasma. This method is based on measurement of the native fluorescence of both drugs in acetonitrile at λem 330 and 470 nm after excitation at 280 and 275 nm for tadalafil and vardenafil, respectively. Linear relationships were obtained over the concentration range 4-40 and 10-250 ng/mL with a minimum detection of 1 and 3 ng/mL for tadalafil and vardenafil, respectively. Various experimental parameters affecting the fluorescence intensity were carefully studied and optimized. The developed method was applied successfully for the determination of tadalafil and vardenafil in bulk drugs and tablet dosage forms. Moreover, the high sensitivity of the proposed method permitted their determination in spiked human plasma. The developed method was validated in terms of specificity, linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), precision and accuracy. The mean recoveries of the analytes in pharmaceutical preparations were in agreement with those obtained from the comparison methods, as revealed by statistical analysis of the obtained results using Student's t-test and the variance ratio F-test. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Ulu, Sevgi Tatar
2009-06-01
A highly sensitive spectrofluorimetric method was developed for the first time, for the analysis of three fluoroquinolones (FQ) antibacterials, namely enrofloxacin (ENR), levofloxacin (LEV) and ofloxacin (OFL) in pharmaceutical preparations through charge transfer (CT) complex formation with 2,3,5,6-tetrachloro- p-benzoquinone (chloranil,CLA). At the optimum reaction conditions, the FQ-CLA complexes showed excitation maxima ranging from 359 to 363 nm and emission maxima ranging from 442 to 488 nm. Rectilinear calibration graphs were obtained in the concentration range of 50-1000, 50-1000 and 25-500 ng mL -1 for ENR, LEV and OFL, respectively. The detection limit was found to be 17 ng mL -1 for ENR, 17 ng mL -1 for LEV, 8 ng mL -1 for OFL, respectively. Excipients used as additive in commercial formulations did not interfere in the analysis. The method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness. The proposed method was successfully applied to the analysis of pharmaceutical preparations. The results obtained were in good agreement with those obtained using the official method; no significant difference in the accuracy and precision as revealed by the accepted values of t- and F-tests, respectively.
Novel fluorimetric assay of trace analysis of epinephrine in human serum
NASA Astrophysics Data System (ADS)
Adeniyi, William K.; Wright, Ashleigh R.
2009-12-01
A simple, rapid, and sensitive spectrofluorimetric technique for the microdetermination of epinephrine in human serum is described. The investigation shows that trace amounts of epinephrine, antidepressant of clinical importance, can be determined without the conventional derivatization or use of fluorophores by diazotization. The method is based on the optimization of experimental parameters, such as pH, temperature, careful selection of excitation and emission wavelengths and on the use of anionic surfactant, sodium dodecyl sulfate (SDS), to enhance sensitivity. The measurement was carried out at 360 nm with excitation at 286 nm. Under the optimum conditions, a linear relationship was obtained between the fluorescence intensity and epinephrine concentration in the range of 0.10 and 1.0 μg/mL; the correlation coefficient and detection limit are 0.9953 and 0.05 μg/mL, respectively. Recovery tests indicated an efficiency of 95.5-98.7% by using known amounts of epinephrine spiked with human serum.
Shah, Jasmin; Jan, M Rasul; Khan, M Naeem; Shah, Sultan
2013-01-01
A sensitive and accurate spectrofluorimetric method has been developed for the determination of sulpiride in pharmaceutical preparations and human plasma. The developed method is based on the derivatization reaction of 2-cyanoacetamide with sulpiride in 30% ammonical solution. The fluorescent derivatized reaction product exhibited maximum fluorescence intensity at 379 nm after excitation at 330 nm. The optimum conditions for derivatization reactions were studied and the fluorescence intensity versus concentration plot was found to be linear over the concentration range 0.2-20.0 µg/mL with a correlation coefficient of 0.9985. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.82 and 2.73 ng/mL, respectively. The proposed method was validated according to ICH guidelines. The effects of common excipients and co-administered drugs were also studied. The accuracy of the method was checked using the standard addition method and percent recoveries were found to be in the range of 99.00-101.25% for pharmaceutical preparations and 97.00-97.80% for spiked human plasma. The method was successfully applied to commercial formulations and the results obtained for the proposed method were compared with a high-performance liquid chromatography reference method and statistically evaluated using the Student's t-test for accuracy and the variance ratio F-test for precision. A reaction pathway was also proposed. Copyright © 2012 John Wiley & Sons, Ltd.
Youssef, Nadia F
2003-01-01
Three sensitive spectrophotometric, spectrofluorimetric, and densitometric methods are described for the determination of indapamide. The first and second methods are based on the oxidative coupling reaction of indapamide with 3-methyl-2-benzothiazolinone hydrazone HCl (MBTH) in the presence of cerium(IV) ammonium sulfate in an acidic medium. The absorbance of the reaction product is measured at the lambdamax, 601 nm. With the same reaction, indapamide is determined by its quenching effect on the fluorescence of excess cerous ions at the emission lambdamax, 350 nm, and the excitation at lambdamax, 300 nm. The reaction conditions were optimized, and Beer's law was obeyed for indapamide at 1.2-9.6 microg/mL with mean recoveries of 99.92 +/- 0.83 and 99.97 +/- 1.11%, respectively. The third method, a stability-indicating densitometric assay, was developed for the determination of indapamide, using toluene-ethyl acetate-glacial acetic acid (69 + 30 + 1, v/v/v) as the developing system and scanning at the lambdamax, 242 nm, in the presence of the degradation product and related substance; for the indapamide concentration range of 0.6-6 microg/spot, the mean recovery was 99.73 +/- 0.71%. The proposed methods were successfully applied to the determination of indapamide in bulk powder and commercial tablets, and the results of the analysis agreed statistically with those obtained with the official method. Furthermore, the methods were validated according to the guidelines of the U.S. Pharmacopeia and also assessed by applying the standard additions technique.
Karimi, Shima; Talebpour, Zahra; Adib, Noushin
2016-06-14
A poly acrylate-ethylene glycol (PA-EG) thin film is introduced for the first time as a novel polar sorbent for sorptive extraction method coupled directly to solid-state spectrofluorimetry without the necessity of a desorption step. The structure, polarity, fluorescence property and extraction performance of the developed thin film were investigated systematically. Carvedilol was used as the model analyte to evaluate the proposed method. The entire procedure involved one-step extraction of carvedilol from plasma using PA-EG thin film sorptive phase without protein precipitation. Extraction variables were studied in order to establish the best experimental conditions. Optimum extraction conditions were the followings: stirring speed of 1000 rpm, pH of 6.8, extraction temperature of 60 °C, and extraction time of 60 min. Under optimal conditions, extraction of carvedilol was carried out in spiked human plasma; and the linear range of calibration curve was 15-300 ng mL(-1) with regression coefficient of 0.998. Limit of detection (LOD) for the method was 4.5 ng mL(-1). The intra- and inter-day accuracy and precision of the proposed method were evaluated in plasma sample spiked with three concentration levels of carvedilol; yielding a recovery of 91-112% and relative standard deviation of less than 8%, respectively. The established procedure was successfully applied for quantification of carvedilol in plasma sample of a volunteer patient. The developed PA-EG thin film sorptive phase followed by solid-state spectrofluorimetric method provides a simple, rapid and sensitive approach for the analysis of carvedilol in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Shnepfe, M.M.
1975-01-01
A sensitive spectrofluorimetric procedure with rhodamine B in the presence of aluminum chloride is given for determining submicrogram and microgram quantities of thallium in silicate rocks. Samples are decomposed with a mixture of hydrofluoric and nitric acids and then treated with hydrochloric acid. Thallium is extracted as its dithizonate with chloroform from an alkaline medium containing ascorbate, citrate, and cyanide and then back-extracted with dilute nitric acid. After destruction of the organic matter and treatment with bromine, hydrochloric acid, aluminum chloride, and rhodamine B, the {A table is presented}. ?? 1975.
el-Din, Mohie K Sharaf; Ibrahim, Fawzia; Eid, Manal I; Wahba, Mary E K
2012-01-01
A validated simple, rapid, and selective spectrofluorimetric method was developed for the determination of some antihistaminic H(1) receptor antagonist drugs namely ebastine (EBS), cetirizine dihydrochloride (CTZ), and fexofenadine hydrochloride (FXD). The method is based on the reaction of the cited drugs with some Π acceptors namely p-chloranilic acid (CLA), tetracyanoethylene (TCNE), and 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) to give highly fluorescent derivatives. The fluorescence intensity-concentration plots were rectilinear over the concentration ranges of 0.2-3.0, 0.2-2.5 and 0.15-2.0 μg/ml for EBS with CLA, DDQ, and TCNE respectively; 0.5-7.0, 0.5-6.0, and 0.2-4.0 μg/ml for CTZ with the previously mentioned reagents, and 0.2-3.5, 0.5-6.0, and 0.2-3.5 μg/ml for FXD. The factors affecting the formation of the reaction products were carefully studied and optimized. The method was applied for the determination of the studied drugs in their dosage forms. The results obtained were in good agreement with those obtained by the comparison methods. Reactions Stoichiometries of the complexes formed between the studied drugs and Π acceptors were defined by the Job's method of the continuous variation and found in 1:1 in all cases.
El-Din, Mohie M K Sharaf; Attia, Khalid A M; Nassar, Mohamed W I; Kaddah, Mohamed M Y
2010-10-15
Two accurate, reliable, and highly sensitive spectrofluorimetric methods were developed for simultaneous determination of binary mixture gemfibrozil and rosiglitazone in human plasma without prior separation steps. The first method is based on synchronous fluorescence spectrometry using double scans. At Δλ=27nm, gemfibrozil yields detectable signal that is independent of the presence of rosiglitazone. Similarly, at Δλ=120nm the signal of rosiglitazone is not influenced by the presence of gemfibrozil. Signals at two wavelengths, 301 (Δλ=27nm) and 368nm (Δλ=120nm) vary linearly with gemfibrozil and rosiglitazone concentrations over the range 100-700ngmL(-1) (for gemfibrozil) and 20-140ngmL(-1) (for rosiglitazone), respectively. The limits of detection (LOD) were 2.3 and 2.72ngmL(-1) for gemfibrozil and rosiglitazone, respectively. The second method is based on the technique of simultaneous equations (Vierodt's method), in which 258nm was selected as the excitation wavelength. Two equations are constructed based on the fact that at ( λ(EM)₂=302 nm of gemfibrozil) and (λ(EM)₂=369 nm of rosiglitazone) the fluorescence of the mixture is the sum of the individual fluorescence of gemfibrozil and rosiglitazone. The limits of detection (LOD) were 28.1 and 23.63ngmL(-1) for gemfibrozil and rosiglitazone, respectively. The proposed methods were successfully applied for the determination of the two compounds in synthetic mixtures and in human plasma with a good recovery. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
El-Didamony, A. M.; Hafeez, S. M.
2016-01-01
Four simple, sensitive spectrophotometric and spectrofluorimetric methods (A-D) for the determination of antibacterial drug lomefloxacin (LMFX) in pharmaceutical formulations have been developed. Method A is based on formation of ternary complex between Pd(II), eosin and LMFX in the presence of methyl cellulose as surfactant and acetate-HCl buffer pH 4.0. Spectrophotometrically, under the optimum conditions, the ternary complex showed absorption maximum at 530 nm. Methods B and C are based on redox reaction between LMFX and KMnO4 in acid and alkaline media. In indirect spectrophotometry method B the drug solution is treated with a known excess of KMnO4 in H2SO4 medium and subsequent determination of unreacted oxidant by reacting it with safronine O in the same medium at λmax = 520 nm. Direct spectrophotometry method C involves treating the alkaline solution of LMFX with KMnO4 and measuring the bluish green product at 604 nm. Method D is based on the chelation of LMFX with Zr(IV) to produce fluorescent chelate. At the optimum reaction conditions, the drug-metal chelate showed excitation maxima at 280 nm and emission maxima at 443 nm. The optimum experimental parameters for the reactions have been studied. The validity of the described procedures was assessed. Statistical analysis of the results has been carried out revealing high accuracy and good precision. The proposed methods were successfully applied for the determination of the selected drug in pharmaceutical preparations with good recoveries.
NASA Astrophysics Data System (ADS)
Tashkhourian, Javad; Absalan, Ghodratollah; Jafari, Marzieh; Zare, Saber
2016-01-01
A rapid, simple and inexpensive spectrofluorimetric sensor for determination of doxycycline based on its interaction with thioglycolic acid-capped cadmium telluride quantum dots (TGA/CdTe QDs) has been developed. Under the optimum experimental conditions, the sensor exhibited a fast response time of <10 s. The results revealed that doxycycline could quench the fluorescence of TGA/CdTe QDs via electron transfer from the QDs to doxycycline through a dynamic quenching mechanism. The sensor permitted determination of doxycycline in a concentration range of 1.9 × 10-6-6.1 × 10-5 mol L-1 with a detection limit of 1.1 × 10-7 mol L-1. The sensor was applied for determination of doxycycline in honey and human serum samples.
Kara, Derya; Fisher, Andrew; Hill, Steve J
2008-03-17
An on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a water-soluble complex. The excitation and emission wavelengths were 423.0 and 553.0nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 degrees C. An interference from fluoride ions was minimised by the addition of Be(2+). Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability, detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000microgL(-1) (r=0.999). The limit of detection (3sigma) for the determination of Al(III) was 0.057microgL(-1) and the precision for multiple determinations of 3ngmL(-1) Al(III) prepared in ultra-pure water was found to be 0.62% (n=10). The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both freshwater and saline solutions, including seawater.
El-Kimary, Eman I; El-Yazbi, Amira F
2016-06-15
A new rapid and highly sensitive stability-indicating spectrofluorimetric method was developed for the determination of two stereoisomers anticancer drugs, doxorubicin (DOX) and epirubicin (EPI) in pure form and in pharmaceutical preparations. The fluorescence spectral behavior of DOX and EPI in a sodium dodecyl sulfate (SDS) micellar system was investigated. It was found that the fluorescence intensity of DOX and EPI in an aqueous solution of phosphate buffer pH4.0 and in the presence of SDS was greatly (about two fold) enhanced and the mechanism of fluorescence enhancement effect of SDS on DOX was also investigated. The fluorescence intensity of DOX or EPI was measured at 553nm after excitation at 497nm. The plots of fluorescence intensity versus concentration were rectilinear over a range of 0.03-2μg/mL for both DOX and EPI with good correlation coefficient (r>0.999). High sensitivity to DOX and EPI was attained using the proposed method with limits of detection of 10 and 9ng/mL and limits of quantitation of 29 and 28ng/mL, for DOX and EPI, respectively. The method was successfully applied for the determination of DOX and EPI in biological fluids and in their commercial pharmaceutical preparations and the results were concordant with those obtained using a previously reported method. The application of the proposed method was extended to stability studies of DOX following different forced degradation conditions (acidic, alkaline, oxidative and photolytic) according to ICH guidelines. Moreover, the kinetics of the alkaline and oxidative degradation of DOX was investigated and the apparent first-order rate constants and half-life times were calculated. Copyright © 2016 Elsevier B.V. All rights reserved.
Plackett-Burman and Box-Behnken designs as chemometric tools for micro-determination of L-Ornithine
NASA Astrophysics Data System (ADS)
Elazazy, Marwa S.; El-Hamshary, Marwa; Sakr, Marwa; Al-Easa, Hala S.
2018-03-01
Plackett-Burman (PB) and Box-Behnken (BB) screening and response surface factorial designs were used to evaluate spectrophotometric and spectrofluorimetric approaches for the determination of L-Ornithine (ORN) as per se and in dietary supplements. Both approaches were based on the derivatization of the primary amino group of ORN via Hantzsch condensation reaction producing yellow coloured adducts (dihydrolutidine derivative). The reaction product was determined spectrophotometrically (method A) at λmax = 327 nm and spectrofluorimetrically (method B) at 480 nm (λem) after excitation at 325 nm (λex). A multivariate scheme was tailored to investigate the process numerical variables; reaction temperature, heating time, reagent volume, and pH implementing PB as a screening design followed by BB as an optimization strategy. Categorical factors including diluting solvent and sequence of addition were kept invariable. Responses of the reaction systems were the maximum absorbance (Y1) and maximum fluorescence intensity (Y2), correspondingly. Quality tools as well as ANOVA testing, before and after response transformation were used to decide upon the substantial variables. Following the optimization of reaction variables using desirability plots, calibration graphs were found to be rectilinear in the range of 6-14 μg/mL and 0.4-1.2 μg/mL for methods A and B, respectively. Both methods proved to be sensitive with detection limits (DL) of 337 and 85 ng/mL, and quantitation limits (QL) of 1086 and 283 ng/mL, for methods A and B, respectively. An interference study was performed using potential foreign species. No significant interference effect was observed on any of the proposed procedures. System performance was addressed following ICH guidelines and considering parameters such as linearity, detection and quantification limits, accuracy and precision, robustness and specificity.
Tashkhourian, Javad; Absalan, Ghodratollah; Jafari, Marzieh; Zare, Saber
2016-01-05
A rapid, simple and inexpensive spectrofluorimetric sensor for determination of doxycycline based on its interaction with thioglycolic acid-capped cadmium telluride quantum dots (TGA/CdTe QDs) has been developed. Under the optimum experimental conditions, the sensor exhibited a fast response time of <10s. The results revealed that doxycycline could quench the fluorescence of TGA/CdTe QDs via electron transfer from the QDs to doxycycline through a dynamic quenching mechanism. The sensor permitted determination of doxycycline in a concentration range of 1.9×10(-6)-6.1×10(-5)molL(-1) with a detection limit of 1.1×10(-7)molL(-1). The sensor was applied for determination of doxycycline in honey and human serum samples. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Manafi, Mohammad Hanif; Allahyari, Mehdi; Pourghazi, Kamyar; Amoli-Diva, Mitra; Taherimaslak, Zohreh
2015-07-01
The extraction and preconcentration of total aflatoxins (including aflatoxin B1, B2, G1, and G2) using magnetic nanoparticles based solid phase extraction (MSPE) followed by surfactant-enhanced spectrofluorimetric detection was proposed. Ethylene glycol bis-mercaptoacetate modified silica coated Fe3O4 nanoparticles as an efficient antibody-free adsorbent was successfully applied to extract aflatoxins from wheat samples. High surface area and strong magnetization properties of magnetic nanoparticles were utilized to achieve high enrichment factor (97), and satisfactory recoveries (92-105%) using only 100 mg of the adsorbent. Furthermore, the fast separation time (less than 10 min) avoids many time-consuming cartridge loading or column-passing procedures accompany with the conventional SPE. In determination step, signal enhancement was performed by formation of Triton X-100 micelles around the analytes in 15% (v/v) acetonitrile-water which dramatically increase the sensitivity of the method. Main factors affecting the extraction efficiency and signal enhancement of the analytes including pH of sample solution, desorption conditions, extraction time, sample volume, adsorbent amount, surfactant concentration and volume and time of micelle formation were evaluated and optimized. Under the optimum conditions, wide linear range of 0.1-50 ng mL-1 with low detection limit of 0.03 ng mL-1 were obtained. The developed method was successfully applied to the extraction and preconcentration of aflatoxins in three commercially available wheat samples and the results were compared with the official AOAC method.
Tang, Bo; Wang, Yan; Sun, Ying; Shen, Han Xi
2002-01-01
The oxidation reaction of HNSH with H2O2 under the catalysis of HRP was studied in detail. The possible reaction mechanism was discussed. Under optimum experimental conditions, the oxidized product of HNSH had excitation and emission maxima at 296 and 414 nm, respectively. A study to prove the existence of -O-O-H in polyethylene glycols was carried out. The proposed method was successfully applied to the determination of -O-O-H in polyethylene glycols.
Lapat, A; Székelyhidi, L; Hornyák, I
1997-01-01
RDX is one of the most important military explosives. It is a component of some plastic explosives which are frequently used in terrorist attacks. Two fluorimetric methods have been described for the quantitative determination of RDX which are based on the detection of nitrite ions. After a basic decomposition of RDX the nitrite ion can be detected by reaction with 4-aminofluorescein and by reactions forming a lumogallion-gallium(III) complex. These fluorimetric methods have been compared to a photometric reaction (Griess reaction) for determination of nitrite ions. It has been found that the fluorimetric methods have a higher sensitivity than the photometric method and they have been used in a wider concentration range.
Estimation of individual sennosides in plant materials and marketed formulations by an HPTLC method.
Shah, S A; Ravishankara, M N; Nirmal, A; Shishoo, C J; Rathod, I S; Suhagia, B N
2000-04-01
Senna is a well-known drug, used in the Ayurvedic and Allopathic systems of medicine, and is a treatment for constipation. The purgative action of senna and its formulations is due to the presence of sennosides A and B. An HPTLC method has been developed for the determination of individual sennosides (A, B, C, D) without any derivatization in marketed formulations (three tablet formulations, two granule formulations and one liquid formulation) and plant materials (senna leaf and pod). The methanolic solution of a sample was applied on a pre-coated silica gel G60 F254 TLC plate (E. Merck.) and was developed using n-propanol : ethyl acetate : water : glacial acetic acid (3 : 3 : 2 : 0.1 v/v) as the mobile phase. The relative band speeds (Rf values) obtained were 0.35, 0.25, 0.61, 0.46 for sennosides A, B, C and D, respectively. The densitometric response was monitored at 366nm. Calibration curves were found to be linear in the concentration ranges 193-1356, 402-2817, 71-497 and 132-927 ng per spot for sennosides A, B, C, and D, respectively. The correlation coefficients were found to be 0.9978, 0.9987, 0.9939 and 0.9983 respectively for sennosides A, B, C and D. The result obtained with the HPTLC method for total sennoside content was compared with the results using the pharmacopoeial methods (spectrophotometric (British Pharmacopoeia) and spectrofluorimetric (United States Pharmacopeia) using the 'F' test). The results revealed no significant difference in the three different methods for estimation of total sennoside. The proposed HPTLC method was found to be simple, specific, precise, accurate and rapid. It can be used for routine quality control of sennosides or senna-containing formulations for individual sennosides.
Enzymatic activity in the surface microlayer and subsurface water in the harbour channel
NASA Astrophysics Data System (ADS)
Perliński, Piotr; Mudryk, Zbigniew J.; Antonowicz, Józef
2017-09-01
Hydrolytic activity of eight extracellular enzymes was determined spectrofluorimetric method in the surface microlayer and subsurface water in the harbour channel in Ustka. The ranking order of the potential enzyme activity rates in the studied water layers was as follows: lipase > phosphatase > aminopeptidase > β-glucosidase > α-glucosidase > xylanase > cellulase > chitinase. The level of activity of all studied hydrolases was higher in the surface microlayer than subsurface water. No clear gradients in the level of enzymatic activity were determined along the horizontal profile of the studied channel. Activity of extracellular enzymes was strongly influenced by the season.
Vito, Virgina De; Saba, Alessandro; Lee, Hong-Ki; Owen, Helen; Poapolathep, Amnart; Giorgi, Mario
2016-01-25
Grapiprant, a novel pharmacologically active ingredient, acts as a selective EP4 receptor antagonist whose physiological ligand is prostaglandin E2 (PGE2). It is currently under development for use in humans and dogs for the control of pain and inflammation associated with osteoarthritis. The aim of the present study was to develop an easy and sensitive method to quantify grapiprant in canine plasma and to apply the method in a canine patient. Several parameters, both in the extraction and detection method were evaluated. The final mobile phase consisted of ACN:AcONH4 (20 mM) solution, pH 4 (70:30, v/v) at a flow rate of 1 mL/min. The elution of grapiprant and IS (metoclopramide) was carried out in isocratic mode through a Synergi Polar-RP 80A analytical column (150 mm × 4.6 mm). The best excitation and emission wavelengths were 320 and 365 nm, respectively. Grapiprant was extracted from the plasma using CHCl3, which gave a recovery of 88.1 ± 10.22% and a lower limit of quantification (LLOQ) of 10 ng/mL. The method was validated in terms of linearity, limit of detection (LOD), LLOQ, selectivity, accuracy and precision, extraction recovery, stability, and inter-laboratory cross validation, according to international guidelines. The chromatographic runs were specific with no interfering peaks at the retention times of the analyte and IS, as confirmed by HPLC-MS experiments. In conclusion, this was a simple and effective method using HPLC-FL to detect grapiprant in plasma, which may be useful for future pharmacokinetic studies. Copyright © 2015 Elsevier B.V. All rights reserved.
Spectrofluorimetric study of the interaction of the mycotoxin citrinin with gold nanoparticles
USDA-ARS?s Scientific Manuscript database
Citrinin is a nephrotoxic secondary metabolite produced by certain fungal species from the Aspergillus, Penicillium, and Monascus genera. Citrinin producing species occasionally contaminate grains, and may pose food safety risks. Analysis of this mycotoxin is frequently carried out by liquid chromat...
An evaluation of the automated assay of urinary oestrogens in pregnant women
Muir, G. G.; Ryan, M.; Conaill, D. U.
1970-01-01
An automated assay suitable for estimating urinary oestrogens in pregnant women has been investigated. Fluorimetry was found to have considerable advantages over colorimetry. The fluorimetric assay was simpler, more precise, more sensitive, and eliminated the need for correction for non-specific chromogens; in the assay of oestriol in pregnant women there was no need for correction for non-specific fluorescence. Spectrofluorimetric and photometric analyses, recoveries, and reproducibility show that the method offers a robust means of providing values for urinary oestrogen in pregnant women on a scale of up to 100 tests a day, the time of the assay being one and a half hours. PMID:5476876
NASA Astrophysics Data System (ADS)
Tang, Bo; Wang, Yan; Chen, Zhen-zhen
2002-10-01
The coupled reaction of N, N-dimethylaniline (DMA) with 4-aminoantipyrine (4-AAP) using superoxide anion radical (O 2-) as oxidizing agent under the catalysis of horseradish peroxidase (HRP) was studied. Based on the reaction, O 2- produced by irradiating Vitamin B 2, (V B2) was spectrophotometricly determined at 554 nm. The linear range of this method was 1.8×10 -6-1.2×10 -4 mol l -1 with a detection limit of 5.3×10 -7 mol l -1. The effect of interferences on the determination of O 2- was investigated. The proposed method was successfully applied to the determination of superoxide dismutase (SOD) activity in human blood and mouse blood.
Insausti, Matías; Fernández Band, Beatriz S
2015-04-05
A highly sensitive spectrofluorimetric method has been developed for the determination of 2-ethylhexyl nitrate in diesel fuel. Usually, this compound is used as an additive in order to improve cetane number. The analytical method consists in building the chemometric model as a first step. Then, it is possible to quantify the analyte with only recording a single excitation-emission fluorescence spectrum (EEF), whose data are introduced in the chemometric model above mentioned. Another important characteristic of this method is that the fuel sample was used without any pre-treatment for EEF. This work provides an interest improvement to fluorescence techniques using the rapid and easily applicable EEF approach to analyze such complex matrices. Exploding EEF was the key to a successful determination, obtaining a detection limit of 0.00434% (v/v) and a limit of quantification of 0.01446% (v/v). Copyright © 2015 Elsevier B.V. All rights reserved.
New highly sensitive and selective fluorescent terbium complex for the detection of aluminium ions
NASA Astrophysics Data System (ADS)
Anwar, Zeinab M.; Ibrahim, Ibrahim A.; Kamel, Rasha M.; Abdel-Salam, Enas T.; El-Asfoury, Mahmoud H.
2018-02-01
A highly sensitive and selective spectrofluorimetric method has been developed for the rapid determination of aluminium ions. The method is based on the fluorescence enhancement of Tb complex with 3,4-dimetyl-thieno[2,3 b] thiophene-2,5-dicarboxylic acid (LN) after addition trace amount of aluminium ions. The fluorescence of the probe is monitored at the characteristic an emission wavelength of Tb3+ at 545 nm with excitation at 300 nm. Optimum detection was obtained in DMSO-H2O (2:8, v/v) and at pH 6.0 using MOPSO buffer. Under the optimum conditions linear calibration curves were obtained from 0.5 μ mol L-1 to 20 μ mol L-1 with detection limit of 0.1 μ mol L-1. Effect of interference of other ions was studied.
Assessing FRET using Spectral Techniques
Leavesley, Silas J.; Britain, Andrea L.; Cichon, Lauren K.; Nikolaev, Viacheslav O.; Rich, Thomas C.
2015-01-01
Förster resonance energy transfer (FRET) techniques have proven invaluable for probing the complex nature of protein–protein interactions, protein folding, and intracellular signaling events. These techniques have traditionally been implemented with the use of one or more fluorescence band-pass filters, either as fluorescence microscopy filter cubes, or as dichroic mirrors and band-pass filters in flow cytometry. In addition, new approaches for measuring FRET, such as fluorescence lifetime and acceptor photobleaching, have been developed. Hyperspectral techniques for imaging and flow cytometry have also shown to be promising for performing FRET measurements. In this study, we have compared traditional (filter-based) FRET approaches to three spectral-based approaches: the ratio of acceptor-to-donor peak emission, linear spectral unmixing, and linear spectral unmixing with a correction for direct acceptor excitation. All methods are estimates of FRET efficiency, except for one-filter set and three-filter set FRET indices, which are included for consistency with prior literature. In the first part of this study, spectrofluorimetric data were collected from a CFP–Epac–YFP FRET probe that has been used for intracellular cAMP measurements. All comparisons were performed using the same spectrofluorimetric datasets as input data, to provide a relevant comparison. Linear spectral unmixing resulted in measurements with the lowest coefficient of variation (0.10) as well as accurate fits using the Hill equation. FRET efficiency methods produced coefficients of variation of less than 0.20, while FRET indices produced coefficients of variation greater than 8.00. These results demonstrate that spectral FRET measurements provide improved response over standard, filter-based measurements. Using spectral approaches, single-cell measurements were conducted through hyperspectral confocal microscopy, linear unmixing, and cell segmentation with quantitative image analysis. Results from these studies confirmed that spectral imaging is effective for measuring subcellular, time-dependent FRET dynamics and that additional fluorescent signals can be readily separated from FRET signals, enabling multilabel studies of molecular interactions. PMID:23929684
Assessing FRET using spectral techniques.
Leavesley, Silas J; Britain, Andrea L; Cichon, Lauren K; Nikolaev, Viacheslav O; Rich, Thomas C
2013-10-01
Förster resonance energy transfer (FRET) techniques have proven invaluable for probing the complex nature of protein-protein interactions, protein folding, and intracellular signaling events. These techniques have traditionally been implemented with the use of one or more fluorescence band-pass filters, either as fluorescence microscopy filter cubes, or as dichroic mirrors and band-pass filters in flow cytometry. In addition, new approaches for measuring FRET, such as fluorescence lifetime and acceptor photobleaching, have been developed. Hyperspectral techniques for imaging and flow cytometry have also shown to be promising for performing FRET measurements. In this study, we have compared traditional (filter-based) FRET approaches to three spectral-based approaches: the ratio of acceptor-to-donor peak emission, linear spectral unmixing, and linear spectral unmixing with a correction for direct acceptor excitation. All methods are estimates of FRET efficiency, except for one-filter set and three-filter set FRET indices, which are included for consistency with prior literature. In the first part of this study, spectrofluorimetric data were collected from a CFP-Epac-YFP FRET probe that has been used for intracellular cAMP measurements. All comparisons were performed using the same spectrofluorimetric datasets as input data, to provide a relevant comparison. Linear spectral unmixing resulted in measurements with the lowest coefficient of variation (0.10) as well as accurate fits using the Hill equation. FRET efficiency methods produced coefficients of variation of less than 0.20, while FRET indices produced coefficients of variation greater than 8.00. These results demonstrate that spectral FRET measurements provide improved response over standard, filter-based measurements. Using spectral approaches, single-cell measurements were conducted through hyperspectral confocal microscopy, linear unmixing, and cell segmentation with quantitative image analysis. Results from these studies confirmed that spectral imaging is effective for measuring subcellular, time-dependent FRET dynamics and that additional fluorescent signals can be readily separated from FRET signals, enabling multilabel studies of molecular interactions. © 2013 International Society for Advancement of Cytometry. Copyright © 2013 International Society for Advancement of Cytometry.
Taskiran, Derya Topkaya; Urut, Gulsiye Ozturk; Ayata, Sevda; Alp, Serap
2017-03-01
4-(4'-acetyloxy-3'-methoxybenzylidene)-5-oxazolone fluorescent molecules bearing four different aryl groups attached to the 2-position of 5-oxazolone ring have been investigated by spectrophotometric and potentiometric techniques in solution media. The acidity constants (pKa) of the fluorescent molecules were precisely determined in acetone, acetonitrile, dimethylformamide and in 1:1 mixture of toluene-isopropanol. The studied derivatives were titrated with tetrabutylammonium hydroxide and non-aqueous perchloric acid by scanning the basic and acidic region of the pH scale. A computerizable derivative method was used in order to descript precisely the end point and pKa values. The molecules investigated performed well-shaped and stoichiometric potentiometric titration curves.
Spagnuolo, M L; Marini, F; Sarabia, L A; Ortiz, M C
2017-05-15
Bisphenol A (BPA) is one of the most largely produced chemical in the world; it is used to make plastics and epoxy resins. The endocrine disruptor potential of BPA is well known, but recent researches suggest a relationship between chronic exposure to BPA, genotoxic activity and epigenetic modifications. The main source of exposure to BPA includes food contact materials (FCM). Thus simple and robust test methods are needed to improve the migration test of BPA. In this work, a non-separative, easy, fast and inexpensive spectrofluorimetric method based on the second order calibration of excitation-emission fluorescence matrices (EEMs) was proposed for the determination of BPA. For the first time, molecular fluorescence was used to identify unequivocally and quantify BPA. Trilinearity of the data tensor guarantees the uniqueness of the solution obtained through parallel factor analysis (PARAFAC), so one factor of the decomposition matches up with BPA even if other fluorophores are in the test sample. The effect of four experimental factors of the procedure on the figures of merit and the unequivocally identification was investigated by means of a D-optimal design and PARAFAC calibration. The method is linear and accurate in the range 0-720µgL -1 . The decision limit CCα and detection capability CCβ are 6.63µgL -1 and 18.85µgL -1 respectively (with probabilities of false positive and false negative fixed at 0.05). Finally the proposed method was applied to carry out a migration test from two polycarbonate cups, using 3% (w/v) acetic acid in aqueous solution as food simulant. The migrated amount of BPA was found to be 688.7µgL -1 (n=5) for the first cup and 710.5µgL -1 (n=4) for the second one, above the specific migration limit set by EFSA (European Food Safety Authority). Copyright © 2017 Elsevier B.V. All rights reserved.
Azmi, Syed Najmul Hejaz; Al-Fazari, Ahlam; Al-Badaei, Munira; Al-Mahrazi, Ruqiya
2015-12-01
An accurate, selective and sensitive spectrofluorimetric method was developed for the determination of citalopram hydrobromide in commercial dosage forms. The method was based on the formation of a fluorescent ion-pair complex between citalopram hydrobromide and eosin Y in the presence of a disodium hydrogen phosphate/citric acid buffer solution of pH 3.4 that was extractable in dichloromethane. The extracted complex showed fluorescence intensity at λem = 554 nm after excitation at 259 nm. The calibration curve was linear over at concentrations of 2.0-26.0 µg/mL. Under optimized experimental conditions, the proposed method was validated as per ICH guidelines. The effect of common excipients used as additives was tested and the tolerance limit calculated. The limit of detection for the proposed method was 0.121 μg/mL. The proposed method was successfully applied to the determination of citalopram hydrobromide in commercial dosage forms. The results were compared with the reference RP-HPLC method. Copyright © 2015 John Wiley & Sons, Ltd.
Analytical investigation of the influence of ornidazole on the native protein fluorescence.
Ali, Hazim M; El-Hashemy, Mohammed A
2018-05-03
A novel spectrofluorimetric method for the determination of ornidazole (ORN) in pure form and dosage forms was developed based on the influence of ORN on the native fluorescence of bovine serum albumin (BSA) in a stimulated physiological environment. The obtained data reveal that the presence of ORN has a strong quenching effect on the fluorescence of BSA through both a dynamic and a static process. The parameters of the binding of ORN to BSA were calculated at different temperatures. Thermodynamic parameters values suggest a role of electrostatic and hydrophobic forces in the binding of ORN to BSA. The investigated method for the determination of ORN is accurate, precise and sensitive with a detection limit of 0.106 μg/mL and a quantification limit of 0.353 μg/mL. The quenching method was applied successfully in the determination of ORN in pure form and dosage forms. Copyright © 2018 Elsevier B.V. All rights reserved.
Leroy, P; Decolin, D; Nicolas, A; Archimbault, P
1994-12-01
A simple, selective and sensitive high-performance liquid chromatographic (HPLC) method has been developed for the measurement of josamycin residues in four porcine tissues (i.e., muscle, liver, kidney and fat). The sample preparation consisted of a homogenization step in an acetonitrile-10 mmol l-1 phosphate buffer mixture, pH 6.0 (35 + 65), centrifugation and a liquid-liquid extractive clean-up of the resulting supernatant with isooctane. Pre-column derivatization of josamycin was performed using cyclohexa-1,3-dione in ammonium acetate buffer, pH 5.0 (90 degrees C for 2 h). The derivative was chromatographed in an isocratic reversed-phase HPLC system. A LiChrospher RP 18 end-capped (5 microns) column was eluted with an acetonitrile-methanol-10 mmol l-1 phosphate buffer mixture, pH 6.0 (45 + 5 + 50). The capacity factor of the josamycin derivative was 17.5. Detection was achieved using spectrofluorimetry (lambda ex = 375 nm; lambda em = 450 nm). The structure of the derivative was assessed by using mass spectrometry. Full selectivity was obtained in the HPLC system versus other macrolide antibiotics (tylosin, spiramycin and erythromycin), aldehydes (formaldehyde, acetaldehyde and benzaldehyde) and endogenous compounds. Linearity and repeatability were tested. Correlation coefficients, for calibration curves in the range of 0.1-3.2 micrograms g-1, were greater than 0.999 for all tissues and the relative standard deviation (S(r)) was 4.9% (1.6 micrograms g-1; n = 6); recovery was higher than 88%.
Kaykhaii, Massoud; Yahyavi, Hossain; Hashemi, Mohammad; Khoshroo, Mohammad Reza
2016-07-01
Determination of malondialdehyde (MDA) in human blood plasma is important because of its role as a biomarker of lipid peroxidation in biological and medical sciences. In this work, a miniaturized graphene-based pipette tip solid-phase extraction technique was developed for very efficient extraction of MDA as its dithiobarbituric acid (TBA) adduct from human plasma. Two milligrams of graphene as sorbent were placed into a pipette tip and MDA-TBA compound was extracted and preconcentrated by it, after 4 repeated aspirating/dispensing cycles, then the column was eluted with 80 μL of dimethyl sulfoxide by 4 repeated aspirating/dispensing cycles and elusion was measured spectrofluorimetrically. Various effective parameters such as type and volume of eluent solvent, temperature, sample volume, number of cycles of extraction and desorption, derivatization reaction time, and pH of the sample solution were investigated and optimized. Under optimum conditions, a linear calibration curve was obtained in the range of 0.5-90 μg L(-1) (r (2) = 0.991) with a detection limit of 0.3 μg L(-1). The relative standard deviations for 8 replicate measurements of 10 and 40 μg L(-1) of MDA were found to be 4.51 and 3.78 % respectively. The developed protocol was successfully applied to the determination of MDA in a human blood plasma sample. Graphical Abstract A simple graphene-based pipette tip solid-phase extraction of malondialdehyde from human plasma and its determination by spectrofluorometry.
A model to estimate the relative position of sites for ligands in serum albumins
NASA Astrophysics Data System (ADS)
Motta, Art Adriel Emidio de Araújo; Grassini, Maria Carolina Vilela; Cortez, Célia Martins; Silva, Dilson
2017-11-01
In this work, we present a mathematical-computational model developed to estimate the relative position of ligand binding sites in HSA and BSA, based on the theory of fluorescence quenching, considering the molecular and spectrofluorimetric differences and similarities between these two albumins. Albumin is the largest and the most abundant serum protein in vertebrates. The ability to bind xenobiotics makes albumin important to the bioavailability and effectiveness of drugs.
Chow, Cheuk-Fai; Lam, Michael H W; Wong, Wai-Yeung
2013-09-03
The detection of neutral biogenic amines plays a crucial role in food safety. Three new heterobimetallic Ru(II)-Ln(III) donor-acceptor complexes, KPrRu, KNdRu, and KSmRu, K{[Ru((II))((t)Bubpy)(CN)4]2-Ln((III))(H2O)4} (where (t)Bubpy = 4,4'-di-tert-butyl-2,2'-bipyridine), have been synthesized and characterized. Their photophysical and X-ray crystallographic data were reported in this study. These complexes were found to be selective for biogenic amine vapors, such as histamine, putrescine, and spermidine, with a detection limit down to the ppb level. The sensitivities of these complexes to the amines were recorded as ~log K = 3.6-5.0. Submicron rods of the complexes, with a nanoscale diameter and microscale length, were obtained through a simple precipitation process. Free-standing polymeric films with different degrees of porosity were fabricated by blending the submicron rods with polystyrene polymer. The polymer with the highest level of porosity exhibited the strongest luminescence enhancement after amine exposure. Real time monitoring of gaseous biogenic amines was applied to real fish samples (Atlantic mackerel) by studying the spectrofluorimetric responses of the Ru(II)-Ln(III) blended polymer film.
Abergel, Rebecca J.; D'Aléo, Anthony; Leung, Clara Ng Pak; Shuh, David K.; Raymond, Kenneth N.
2009-01-01
While widely used in bioassays, the spectrofluorimetric method described here uses the antenna effect as a tool to probe the thermodynamic parameters of ligands that sensitize lanthanide luminescence. The Eu3+ coordination chemistry, solution thermodynamic stability and photophysical properties of the spermine-based hydroxypyridonate octadentate chelator 3,4,3-LI(1,2-HOPO) are reported. The complex [EuIII(3,4,3-LI(1,2-HOPO))]- luminesces with a long lifetime (805 μs) and a quantum yield of 7.0% in aqueous solution, at pH 7.4. These remarkable optical properties were exploited to determine the high (and proton-independent) stability of the complex (log β110 = 20.2(2)) and to define the influence of the ligand scaffold on the stability and photophysical properties. PMID:19902920
[Urinary excretion of catecholamines in obese subjects and in diabetics (author's transl)].
Giorgino, R; Nardelli, G M; Scardapane, R
1976-03-01
95 obese subjects, 40 diabetics and 22 normal controls were investigated. The weight of all obese subjects was at least 20% higher than the ideal weight. Catecholamine excretion was determined a few days after hospitalization to minimize the influence of environmental changes. Spectrofluorimetric estimation of adrenaline and noradrenaline in the urine was carried out according to the method of von Euler and Lihajko. Statistical analysis of the results showed a significant increase in both adrenaline and noradrenaline excretion in the group of obeses subjects compared with the diabetics. The increased catecholamine excretion may represent the response of the adrenal medulla to the stress of the disease. Such an increase may be responsible for perpheral insulin resistence and hence acts as a diabetogenic factor. The results obtained emphasize the influence of catecholamines on insulin responsiveness, possibly constituting a major contribution to the diabetic state.
Intracellular magnesium detection by fluorescent indicators.
Trapani, Valentina; Schweigel-Röntgen, Monika; Cittadini, Achille; Wolf, Federica I
2012-01-01
Magnesium is essential for a wide variety of biochemical reactions and physiological functions, but its regulatory mechanisms (both at the cellular and at the systemic level) are still poorly characterized. Not least among the reasons for this gap are the technical difficulties in sensing minor changes occurring over a high background concentration. Specific fluorescent indicators are highly sensitive tools for dynamic evaluation of intracellular magnesium concentration. We herein discuss the main criteria to consider when choosing a magnesium-specific fluorescent indicator and provide examples among commercial as well as developmental sensors. We focus on spectrofluorimetric approaches to quantify Mg(2+) concentration in cell or mitochondria suspensions, and on imaging techniques to detect intracellular magnesium distribution and fluxes by live microscopy, reporting a detailed description of standard protocols for each method. The general guidelines we provide should be applicable to specific issues by any researcher in the field. Copyright © 2012 Elsevier Inc. All rights reserved.
Level of endogenous formaldehyde in maple syrup as determined by spectrofluorimetry.
Lagacé, Luc; Guay, Stéphane; Martin, Nathalie
2003-01-01
The level of endogenous formaldehyde in maple syrup was established from a large number (n = 300) of authentic maple syrup samples collected during 2000 and 2001 in the province of Quebec, Canada. The average level of formaldehyde from these authentic samples was measured at 0.18 mg/kg in 2000 and 0.28 mg/kg in 2001, which is lower than previously published. These average values can be attributed to the improved spectrofluorimetric method used for the determination. However, the formaldehyde values obtained demonstrate a relatively large distribution with maximums observed at 1.04 and 1.54 mg/kg. These values are still under the maximum tolerance level of 2.0 mg/kg paraformaldehyde pesticide residue. Extensive heat treatment of maple syrup samples greatly enhanced the formaldehyde concentration of the samples, suggesting that extensive heat degradation of the sap constituents during evaporation could be responsible for the highest formaldehyde values in maple syrup.
Analysis of limette and bergamot distilled essential oils by HPLC.
Buiarelli, Francesca; Cartoni, Giampaolo; Coccioli, Franco; Jasionowska, Renata; Mazzarino, Monica
2002-04-01
This work examines the distilled essential oils of limette and bergamot in order to assess the presence of low volatile substances such as coumarins (bergapten) which, being toxic, must be eliminated before using these oils in the food industry. The quantitative determination of coumarins was carried out by spectrofluorimetric detection. The substances present in the chromatograms, obtained by HPLC with UV detection at 254 nm, were then identified. Moreover, a new coumarin that is present in small quantities was identified using HPLC-MS.
Automated laser spectrofluorimeter for monitoring of myocardial metabolism
NASA Astrophysics Data System (ADS)
Popov, A. Yu.; Salmin, V. V.; Fursov, A. A.; Stepanenko, A. V.; Sokolovich, A. G.; Salmina, A. B.; Rebenkova, A. A.; Makarov, R. A.; Provorov, A. S.
2006-09-01
Methods of optical biopsy have a series of advantages before other methods of clinical diagnostics. The high accuracy of received results enables registration even small change of concentration of substances, and the opportunity of remote registration makes methods optical biopsy by an optimum means for noninvasive methods of diagnostics in medicine. The method of the fluorescent analysis allows to investigate dynamics of changes of a functional condition of organs and tissue in norm and pathologies, called by the various factors (an inflammation, ischemia, degenerative changes). Bring the results of development of expiremental setup for the laser fluorescent analysis of physiological and functional condition of various organs and tissue of organism. In expiremental setup was used pulse UF nitric laser with length of wave generation = 337 nm. For delivery of radiation to tissue, and, also, collection of a radiation of fluorescence were used various optic fiber scheme. The expiremental setup includes automated tunable monochromator and ADC, receiving a signal from photomultiplier tube. Driving of all blocks and processing of results is realize on IBM-compatible computer with the appropriate software. Was used the synchronous detecting for reducing of a background signal. Myocard at surgical introoperation by an accompanied condition of sharp ischemia was researches on these expiremental setup. Spectrofluorimetric criteria of an estimation of a condition of viscus at peritonitis were development.
Madrakian, Tayyebeh; Bagheri, Habibollah; Afkhami, Abbas
2015-08-01
A sensitive spectrofluorimetric method using constant-energy synchronous fluorescence technique is proposed for the determination of human albumin without separation. In this method, no reagent was used for enhancement of the fluorescence signal of albumin in the solution. Effects of some parameters, such as energy difference between excitation and emission monochromators (ΔE), emission and excitation slit widths and scan rate of wavelength were studied and the optimum conditions were established. For this purpose factorial design and response surface method were employed for optimization of the effective parameters on the fluorescence signal. The results showed that the scan rate of the wavelength has no significant effect on the analytical signal. The calibration curve was linear in the range 0.1-220.0 µg mL(-1) of albumin with a detection limit of 7.0 × 10(-3) µg mL(-1). The relative standard deviations (RSD) for six replicate measurements of albumin were calculated as 2.2%, 1.7% and 1.3% for 0.5, 10.0 and 100.0 µg mL(-1) albumin, respectively. Furthermore the proposed method has been employed for the determination of albumin in human serum and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.
Dabrzalska, Monika; Zablocka, Maria; Mignani, Serge; Majoral, Jean Pierre; Klajnert-Maculewicz, Barbara
2015-08-15
Dendrimers due to their unique architecture may play an important role in drug delivery systems including chemotherapy, gene therapy and recently, photodynamic therapy as well. We investigated two dendrimer-photosensitizer systems in context of potential use of these systems in photodynamic therapy. The mixtures of an anionic phosphorus dendrimer of the second generation and methylene blue were studied by UV-vis spectroscopy while that of a cationic phosphorus dendrimer (third generation) and rose bengal were investigated by spectrofluorimetric methods. Spectroscopic analysis of these two systems revealed the formation of dendrimer-photosensitizer complexes via electrostatic interactions as well as π stacking. The stoichiometry of the rose bengal-cationic dendrimer complex was estimated to be 7:1 and 9:1 for the methylene blue-anionic dendrimer complex. The results suggest that these polyanionic or polycationic phosphorus dendrimers can be promising candidates as carriers in photodynamic therapy. Copyright © 2015 Elsevier B.V. All rights reserved.
Comment: CAPN10 alleles are associated with polycystic ovary syndrome.
Gonzalez, Alejandro; Abril, Eduardo; Roca, Alfredo; Aragón, Maria José; Figueroa, Maria José; Velarde, Pilar; Royo, José Luis; Real, Luis Miguel; Ruiz, Agustín
2002-08-01
Polycystic ovary syndrome (PCOS) is characterized by chronic anovulation infertility, hyperandrogenemia, and frequently insulin resistance. This study investigated whether polymorphisms in the CAPN10 gene are related with PCOS etiology. The allelic frequencies and genotypes of CAPN10 polymorphisms UCSNP-44, 43, 19, and 63 were determined in 55 well characterized women with polycystic ovaries and 93 unrelated healthy controls using spectrofluorimetric analyses and real-time PCR. Our data indicate that CAPN10 UCSNP-44 allele is associated with PCOS in the Spanish population (P = 0.01). These results support a role of Calpain 10 gene in PCOS susceptibility in humans.
Mohsenikia, Atefeh; Gholami, Ali; Masoum, Saeed; Abbasi, Saleheh
2017-09-01
This study presents a new strategy for the simultaneous quantification of two industrial contaminants. The excitation-emission fluorescence data matrix combined with a three-way chemometric method, such as parallel factor analysis, was used for the determination of nonylphenol ethoxylate (NPE-9) as a nonionic surfactant and 2-naphthalene sulfonate (2-NS) in waste water samples. It is noticeable that this method can resolve overlapping signal into spectral and relative concentration profiles. By spiking the known concentrations of these compounds in the wastewater samples, the accuracy of the proposed methods was validated and recoveries of the spiked values were calculated. High recoveries (i.e. 90-110%) obtained for the waste water samples indicate the present method can be used successfully to determine the analytes concentration in the environmental contaminations. The photocatalytic degradation of NPE-9 and 2-NS in aqueous solution was studied using the CoTiO 3 nanoparticles catalyst. It was synthesized by the sol-gel technique. The catalytic activity of the prepared nanoparticles was measured in a batch photoreactor containing appropriate solutions of these compounds with UV irradiation. The photodegradation process of these compounds was optimized by using the central composite design. The CoTiO 3 showed high activity for UV-photocatalytic degradation of NPE-9 and 2-NS.
Concentrations of cadmium and selected essential elements in malignant large intestine tissue
Dziki, Adam; Kilanowicz, Anna; Sapota, Andrzej; Duda-Szymańska, Joanna; Daragó, Adam
2015-01-01
Introduction Colorectal cancer is one of the most common cancers worldwide. Incidence rates of large intestine cancer indicate a role of environmental and occupational factors. The role of essential elements and their interaction with toxic metals can contribute to the explanation of a complex mechanism by which large intestine cancer develops. Bearing this in mind, determining the levels of essential and toxic elements in tissues (organs), as well as in body fluids, seems to shed light on their role in the mode of action in malignant disease. Aim Determination of the levels of cadmium, zinc, copper, selenium, calcium, magnesium, and iron in large intestine malignant tissue. Material and methods Two intraoperative intestine sections were investigated: one from the malignant tissue and the other one from the normal tissue, collected from each person with diagnosed large intestine cancer. Cadmium, zinc, copper, calcium, magnesium, and iron levels were determined with atomic absorption spectrometry, and selenium levels by spectrofluorimetric method. Results The levels of copper, selenium, and magnesium were higher in the malignant than in normal tissues. In addition, the zinc/copper and calcium/magnesium relationship was altered in malignant tissue, where correlations were lower compared to non-malignant tissue. Conclusions The results seems to demonstrate disturbed homeostasis of some essential elements. However, it is hard to confirm their involvement in the aetiology of colorectal cancer. PMID:27110307
Tryptophan and kynurenine determination in human hair by liquid chromatography.
Dario, Michelli F; Freire, Thamires Batello; Pinto, Claudinéia Aparecida Sales de Oliveira; Prado, María Segunda Aurora; Baby, André R; Velasco, Maria Valéria R
2017-10-15
Tryptophan, an amino acid found in hair proteinaceous structure is used as a marker of hair photodegradation. Also, protein loss caused by several chemical/physical treatments can be inferred by tryptophan quantification. Kynurenine is a photo-oxidation product of tryptophan, expected to be detected when hair is exposed mainly to UVB (290-320nm) radiation range. Tryptophan from hair is usually quantified directly as a solid or after alkaline hydrolysis, spectrofluorimetrically. However, these types of measure are not sufficiently specific and present several interfering substances. Thus, this work aimed to propose a quantification method for both tryptophan and kynurenine in hair samples, after alkali hydrolysis process, by using high-performance liquid chromatography (HPLC) with fluorimetric and UV detection. The tryptophan and kynurenine quantification method was developed and validated. Black, white, bleached and dyed (blond and auburn) hair tresses were used in this study. Tryptophan and kynurenine were separated within ∼9min by HPLC. Both black and white virgin hair samples presented similar concentrations of tryptophan, while bleaching caused a reduction in the tryptophan content as well as dyeing process. Unexpectedly, UV/vis radiation did not promote significantly the conversion of tryptophan into its photo-oxidation product and consequently, kynurenine was not detected. Thus, this works presented an acceptable method for quantification of tryptophan and its photooxidation metabolite kynurenine in hair samples. Also, the results indicated that bleaching and dyeing processes promoted protein/amino acids loss but tryptophan is not extensively degraded in human hair by solar radiation. Copyright © 2017 Elsevier B.V. All rights reserved.
Oladi, Elham; Mohamadi, Maryam; Shamspur, Tayebeh; Mostafavi, Ali
2014-11-11
Melatonin is normally consumed to regulate the body's biological cycle. However it also has therapeutic properties, such as anti-tumor, anti-aging and protects the immune system. There are some reports on the presence of melatonin in edible kernels such as walnuts, but the extraction of melatonin from pistachio kernels is reported here for the first time. For this, the methanolic extract of pistachio kernels was exposed to gas chromatography/mass spectrometry analysis which confirmed the presence of melatonin. A fluorescence-based method was applied for the determination of melatonin in different extracts. When excited at λ=275 nm, the fluorescence emission intensity of melatonin was measured at λ=366 nm. Ultrasound-assisted solid-liquid extraction was used for the extraction of melatonin from pistachio kernels prior to fluorimetric determination. To achieve the highest extraction recovery, the main parameters affecting the extraction efficiency such as extracting solvent type and volume, temperature, sonication time and pH were evaluated. Under the optimized conditions, a linear dependence of fluorescence intensity on melatonin concentration was observed in the range of 0.0040-0.160 μg mL(-1), with a detection limit of 0.0036 μg mL(-1). This method was applied successfully for measuring and comparing the melatonin content in the kernels of four different varieties of Pistacia including Ahmad Aghaei, Akbari, Kalle Qouchi and Fandoghi. In addition, the results obtained were compared with those obtained using GC/MS. A good agreement was observed indicating the reliability of the proposed method. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Oladi, Elham; Mohamadi, Maryam; Shamspur, Tayebeh; Mostafavi, Ali
2014-11-01
Melatonin is normally consumed to regulate the body's biological cycle. However it also has therapeutic properties, such as anti-tumor, anti-aging and protects the immune system. There are some reports on the presence of melatonin in edible kernels such as walnuts, but the extraction of melatonin from pistachio kernels is reported here for the first time. For this, the methanolic extract of pistachio kernels was exposed to gas chromatography/mass spectrometry analysis which confirmed the presence of melatonin. A fluorescence-based method was applied for the determination of melatonin in different extracts. When excited at λ = 275 nm, the fluorescence emission intensity of melatonin was measured at λ = 366 nm. Ultrasound-assisted solid-liquid extraction was used for the extraction of melatonin from pistachio kernels prior to fluorimetric determination. To achieve the highest extraction recovery, the main parameters affecting the extraction efficiency such as extracting solvent type and volume, temperature, sonication time and pH were evaluated. Under the optimized conditions, a linear dependence of fluorescence intensity on melatonin concentration was observed in the range of 0.0040-0.160 μg mL-1, with a detection limit of 0.0036 μg mL-1. This method was applied successfully for measuring and comparing the melatonin content in the kernels of four different varieties of Pistacia including Ahmad Aghaei, Akbari, Kalle Qouchi and Fandoghi. In addition, the results obtained were compared with those obtained using GC/MS. A good agreement was observed indicating the reliability of the proposed method.
Azab, Hassan Ahmed; Anwar, Zeinab M; Abdel-Salam, Enas T; el-Sayed-Sebak, Mahmoud
2012-01-01
Two new ligands derived from phloroglucinol 2-{[(4-methoxy benzoyl)oxy]} methyl benzoic acid[L1] and 2-{[(4-methyl benzoyl)oxy] methyl} benzoic acid[L2] were synthesized. The solid complex Eu(III)-L2 has been synthesised and characterized by elemental analysis, UV and IR spectra. The reaction of Eu(III) with the two synthesized ligands has been investigated in I = 0.1 mol dm(-3) p-toluene sulfonate by cyclic voltammetry and square wave voltammetry. The reaction of Eu (III)-L1 and Eu (III)-L2 binary complexes with nucleotide 5'-AMP, 5'-ADP, 5'-ATP, 5'- GMP, 5'-IMP, and 5'-CMP has been investigated using UV, fluorescence and electrochemical methods. The experimental conditions were selected such that self-association of the nucleotides and their complexes was negligibly small, that is, the monomeric complexes were studied. The interaction of the Eu(III)-L1 or L2 solid complexes with calf-thymus DNA has been investigated by fluorescence and electrochemical methods including cyclic voltammetery(CV), differential pulse polarography (DPP) and square wave voltammetry (SWV) on a glassy carbon electrode. The fluorescence intensity of Eu(III)-L2 complex was enhanced with the addition of DNA. Under optimal conditions in phosphate buffer pH 7.0 at 25 °C the linear range is 3-20 μM for calf thymus DNA (CT-DNA) and the corresponding determination limit is 1.8 μM.
Occupational exposure to coal tar pitch volatiles, benzo/a/pyrene and dust in tyre production.
Rogaczewska, T; Ligocka, D
1994-01-01
Occupational exposure to coal tar pitch volatiles (CTPVs), benzo/a/pyrene (BaP) and dust was evaluated by means of individual measurements carried out in 80 workers and by stationary measurements on 16 work-posts in two divisions of the tyre producing plant. Dust and coal tar pitch volatiles concentrations in the air were determinated by the gravimetric method, measured, in the case of CPTVs, benzene-soluble fraction (BSF) with ultrasonic extraction. Benzo/a/pyrene analysis was performed using high performance liquid chromato-graphy (HPLC) with a spectrofluorimetric detector. It was found that nearly all personal sampling results for BaP were within the range < 4 divided by 142 ng/m3, except for the exposure of workers employed at weighing the raw materials (3,470-6,060 ng/m3) in the Semiproducts Division. Attention should be paid to the recorded CTPVs concentrations (benzene solubles). About 56% of the Vulcanizing Division workers and about 90% of the Semiproducts Division workers were exposed to these substances at concentrations of over 0.2 mg/m3 (hygienic standard for benzene solubles in USA). Exposure to dust (of high respirable fraction percentage > 90%) which exceeded the admissible value (4 mg/m3) was found mainly only in the workers of the Semiproducts Division at some work-posts.
NASA Astrophysics Data System (ADS)
Maity, Subhajit; Chakraborty, Sandipan; Chakraborti, Abhay Sankar
2017-02-01
The present study demonstrates critical insight into the binding of a bioactive flavanone naringenin with normal human haemoglobin (NHb). Both spectrophotometric and spectrofluorimetric studies reveal that naringenin interacts with NHb. The binding affinity constant and number of binding sites appear to be approximately (1.5 ± 0.2) × 104 M-1 and 1, respectively. Static quenching seems to be an important factor in binding process, as evident from steady-state and time-resolved fluorescence spectroscopic studies. Far UV circular dichroism spectroscopy depicts that binding of naringenin to NHb causes no change in the secondary structure of the protein, which is also evident from Fourier transform infrared spectroscopic study. Free energy change (ΔG0) for naringenin-NHb interaction, determined by spectroscopic and isothermal calorimetric method, appears to be -5.67 kcal/mol and -6.90 kcal/mol, respectively, and is close to the docking energy -6.84 kcal/mol. Molecular docking suggests that naringenin binds near the cavity of the tetrameric heme protein, forming hydrogen bonds with surrounding amino acid residues. The binding site is away from the heme moieties, implicating naringenin binding does not affect the oxygen binding capacity of NHb, which makes the protein a suitable carrier of the flavonoid.
Kozurková, Mária; Sabolová, Danica; Janovec, Ladislav; Mikes, Jaromír; Koval', Ján; Ungvarský, Ján; Stefanisinová, Miroslava; Fedorocko, Peter; Kristian, Pavol; Imrich, Ján
2008-04-01
The synthesis of novel 1',1''-(acridin-3,6-diyl)-3',3''-dialkyldiureas was reported. Their biological activity to inhibit cell proliferation was assessed by a MTT assay on two cell lines, HeLa and HCT-116, at micromolar concentration. 1',1''-(Acridin-3,6-diyl)-3',3''-dihexyldiurea hydrochloride was active on a HCT-116 cell line with an IC(50) value of 3.1 microM. The interaction of these compounds with calf thymus DNA was investigated by a variety of spectroscopic techniques including UV-vis, fluorescence and CD spectroscopy. From spectrofluorimetric titrations, binding constants for the DNA-drug complexes were determined (K=0.9-4.2x10(5) M(-1)). Antiproliferative activity of synthesized derivatives might be related to their intercalation into DNA.
Manzano, José Ignacio; Carvalho, Luis; García-Hernández, Raquel; Poveda, José Antonio; Ferragut, José Antonio; Castanys, Santiago; Gamarro, Francisco
2011-11-01
The present study was designed to elucidate the mechanism of tafenoquine uptake in Leishmania and its sterol dependence. Because tafenoquine is a fluorescent compound, spectrofluorimetric analysis allowed us to monitor its uptake by Leishmania promastigotes and intracellular amastigotes, and to evaluate the effect of temperature, energy and H+ gradient on drug entry. The influence of sterols on tafenoquine uptake in Leishmania parasites was determined in experiments using sterol-depleting agents such as methyl-β-cyclodextrin or cholesterol oxidase. Tafenoquine exhibited fast entry kinetics into Leishmania in an energy-independent, but pH- and temperature-dependent, non-saturable process. Furthermore, sterol depletion decreased tafenoquine uptake. These findings suggest that Leishmania takes up tafenoquine by a diffusion process and that decreases in membrane sterol content may induce a decrease in drug uptake.
NASA Astrophysics Data System (ADS)
Escobar, Marta Araujo Cyrino; Cortez, Celia Martins; Silva, Dilson; Neto, Jayme da Cunha Bastos
2017-11-01
The aim of this work is to initiate an investigation on the albumin of Salminus brasiliensis (gold fish) as a biomarker of environmental actions of glyphosate. We started using a mathematical-computational model based on spectrofluorimetric measurements to study the interaction of glyphosate with gold fish albumin and human serum albumin. Salminus brasiliensis is a migratory freshwater fish species found in southern and central-western Brazil, mainly in the Prata river basin, where most of soybean plantations are set. Glyphosate is a very used herbicide in this type of crop. Differently from the organophosphorate methyl parathion, glyphosate does not form complex with HSA, and the quenching constants estimated for its binding with gold fish albumin at 20 °C and 25 °C is 1.3(± 0.3) × 104 / M e 2.5 (± 0.3) × 104 / M, respectively.
Analysis of epothilone B-induced cell death in normal ovarian cells.
Rogalska, Aneta; Gajek, Arkadiusz; Marczak, Agnieszka
2013-12-01
We have investigated the mode of cell death induced by a new microtubule-stabilizing agent, epothilone B (EpoB, patupilone), and a clinically used medicine, paclitaxel (PTX), in normal ovarian cells. Using fluorescence microscopy, polyacrylamide gel electrophoresis preceding Western blot analysis, as well as spectrofluorimetric and colorimetric detection, we demonstrate that, compared to EpoB, PTX induced high time-dependent morphological and biochemical changes typical of apoptosis. Induction of apoptosis followed an early increase in p53 levels. Apoptosis reached its maximum at 24-48 h. At the same time, there was a significant increase in caspase-9 and -3 activity and PARP fragmentation, which suggests that an intrinsic path was involved. Apoptosis in MM14 cells was increased more by PTX than EpoB, and also induced more necrosis responsible for inflammation (1.4-fold) than EpoB. © 2013 International Federation for Cell Biology.
Interaction of sulpiride and serum albumin: Modeling from spectrofluorimetric data
NASA Astrophysics Data System (ADS)
Fragoso, Viviane Muniz da Silva; Silva, Dilson
2015-12-01
We have applied the fluorescence quenching modeling to study the process of interaction of sulpiride with human serum albumin (HSA) and bovine (BSA). Albumin is more abundant protein in blood and it emits fluorescence when excited by 260-295 nm. Sulpiride is an atypical antipsychotic used in the treatment of many psychiatric disorders. As sulpiride is fluorescent, we developed a mathematical model to analyzing the interaction of two fluorescent substances. This model was able to separate the albumin fluorescence from the quencher fluorescence. Results have shown that sulpiride quenches the fluorescence of both albumins by a static process, due to the complex formation drugalbumin. The association constants calculated for sulpiride-HSA was 2.20 (± 0.08) × 104 M-1 at 37° C, and 5.46 (± 0.20) × 104 M-1, 25 ° C, and the primary binding site to sulpiride in the albumin is located closer to the subdomain IB.
NASA Astrophysics Data System (ADS)
Nevin, A.; Anglos, D.; Cather, S.; Burnstock, A.
2008-07-01
Spectrofluorimetric analysis of proteinaceous binding media is particularly promising because proteins employed in paintings are often fluorescent and media from different sources have significantly different fluorescence spectral profiles. Protein-based binding media derived from eggs, milk and animal tissue have been used for painting and for conservation, but their analysis using non-destructive techniques is complicated by interferences with pigments, their degradation and their low concentration. Changes in the fluorescence excitation emission spectra of films of binding media following artificial ageing to an equivalent of 50 and 100 years of museum lighting include the reduction of bands ascribed to tyrosine, tryptophan and Maillard reaction products and an increase in fluorescent photodegradation. Fluorescence of naturally aged paint is dependent on the nature of the pigment present and, with egg-based media, in comparison with un-pigmented films, emissions ascribed to amino acids are more pronounced.
Sekowski, Szymon; Ionov, Maksim; Kaszuba, Mateusz; Mavlyanov, Saidmukhtar; Bryszewska, Maria; Zamaraeva, Maria
2014-11-01
Tannins, secondary plant metabolites, possess diverse biological activities and can interact with biopolymers such as lipids or proteins. Interactions between tannins and proteins depend on the structures of both and can result in changes in protein structure and activity. Because human serum albumin is the most abundant protein in plasma and responsible for interactions with important biological compounds (e.g. bilirubin) and proper blood pressure, therefore, it is very important to investigate reactions between HSA and tannins. This paper describes the interaction between human serum albumin (HSA) and two tannins: bihexahydroxydiphenoyl-trigalloylglucose (BDTG) and 1-O-galloyl-4,6-hexahydroxydiphenoyl-β-d-glucose (OGβDG), isolated from Geranium sanguineum and Oenothera gigas leafs, respectively. Optical (spectrofluorimetric) and chiral optical (circular dichroism) methods were used in this study. Fluorescence analysis demonstrated that OGβDG quenched HSA fluorescence more strongly than BDTG. Both OGβDG and BDTG formed complexes with albumin and caused a red shift of the fluorescence spectra but did not significantly change the protein secondary structure. Our studies clearly demonstrate that the tested tannins interact very strongly with human serum albumin (quenching constant K=88,277.26±407.04 M(-1) and K=55,552.67±583.07 M(-1) respectively for OGβDG and BDTG) in a manner depending on their chemical structure. Copyright © 2014 Elsevier B.V. All rights reserved.
Bazzicalupi, Carla; Bencini, Andrea; Bianchi, Antonio; Biver, Tarita; Boggioni, Alessia; Bonacchi, Sara; Danesi, Andrea; Giorgi, Claudia; Gratteri, Paola; Ingraín, Antonio Marchal; Secco, Fernando; Sissi, Claudia; Valtancoli, Barbara; Venturini, Marcella
2008-01-01
The new bifunctional molecule 3,6-diamine-9-[6,6-bis(2-aminoethyl)-1,6-diaminohexyl]acridine (D), which is characterised by both an aromatic moiety and a separate metal-complexing polyamine centre, has been synthesised. The characteristics of D and its ZnII complex ([ZnD]) (protonation and metal-complexing constants, optical properties and self-aggregation phenomena) have been analysed by means of NMR spectroscopy, potentiometric, spectrophotometric and spectrofluorimetric techniques. The equilibria and kinetics of the binding process of D and [ZnD] to calf thymus DNA have been investigated at I=0.11 M (NaCl) and 298.1 K by using spectroscopic methods and the stopped-flow technique. Static measurements show biphasic behaviour for both D-DNA and [ZnD]-DNA systems; this reveals the occurrence of two different binding processes depending on the polymer-to-dye molar ratio (P/D). The binding mode that occurs at low P/D values is interpreted in terms of external binding with a notable contribution from the polyamine residue. The binding mode at high P/D values corresponds to intercalation of the proflavine residue. Stopped-flow, circular dichroism and supercoiled-DNA unwinding experiments corroborate the proposed mechanism. Molecular-modelling studies support the intercalative process and evidence the influence of NH+...O interactions between the protonated acridine nitrogen atom and the oxygen atoms of the polyanion; these interactions play a key role in determining the conformation of DNA adducts.
Basu, Anirban; Kumar, Gopinatha Suresh
2015-05-30
A biophysical study on the interaction of the food colorant amaranth with hemoglobin was undertaken. Spectrophotometric and spectrofluorimetric studies proposed for an intimate binding interaction between the dye and the protein. The dye quenched the fluorescence of the protein remarkably and the mechanism of quenching was found to be static in nature. Synchronous fluorescence studies suggested that the polarity around the tryptophan residues was altered in the presence of amaranth whereas the polarity around tyrosine residues remained largely unaltered. 3D fluorescence, FTIR and circular dichroism results suggested that the binding reaction caused conformational changes in hemoglobin. The negative far-UV CD bands exhibited a significantly large decrease in magnitude in the presence of amaranth. From calorimetry studies it was established that the binding was driven by a large positive entropic contribution and a small but favorable enthalpy change. Copyright © 2015 Elsevier B.V. All rights reserved.
Chow, Cheuk-Fai; Gong, Fu-Wen; Gong, Cheng-Bin
2014-09-21
Detection of neutral biogenic sulfides plays a crucial role in food safety. A new heterobimetallic Re(I)-Pt(II) donor-acceptor complex--[Re(biq)(CO)3(CN)]-[Pt(DMSO)(Cl)2] (1, biq = 2,2'-biquinoline)--was synthesized and characterized. The X-ray crystallographic and photophysical data for 1 are reported in this study. Complex 1 indicated the luminescent chemodosimetric selectivity for dimethyl sulfide, which persisted even in the presence of a variety of interfering vapors, with a detection limit as low as 0.96 ppm. The binding constant (log K) of 1 toward dimethyl sulfide was 3.63 ± 0.03. The analyte selectivity of the complexes was found to be dependent on the ligand coordinated to the Re(I) center. Real samples (beef, chicken, and pork) were monitored real-time for gaseous dimethyl sulfide. Complex 1 shows a linear spectrofluorimetric response with increasing storage time of the meats at 30 °C.
NASA Astrophysics Data System (ADS)
Ganesh, K.; Elango, K. P.
Raman, UV-vis, FT-IR, and fluorescence spectral techniques were employed to investigate the mechanism of interaction of albendazole (ALB) and trimethoprim (TMP) drugs with iodine. Interactions of ALB and TMP with iodine yields triiodide ion and its formation was confirmed by electronic and Raman spectra. The peaks appeared in Raman spectra of the isolated products are at around 145, 113 and 82 cm-1 are assigned to νas(I-I), νs(I-I) and δ(I3-) respectively, confirmed the presence of I3- ion. Formation constant (K), molar extinction coefficient (ɛ) and thermodynamic properties ΔH#, ΔS# and ΔG# were determined and discussed. Fluorescence quenching studies indicated that the interaction between the ALB, TMP with iodine are spontaneous and the TMP-iodine interaction is found to be stronger than that the other system. Solvent variation studies indicated that the binding constant increased with an increase in polarity of the medium.
Pilarczyk, Bogumiła; Tomza-Marciniak, Agnieszka; Pilarczyk, Renata; Hendzel, Diana; Błaszczyk, Barbara; Bąkowska, Małgorzata
2011-06-01
The aim of the study was to compare selenium concentrations in different organs of roe deer from northwestern Poland. Samples of liver, kidneys, heart and lungs, collected from 74 roe deer shot during the hunting seasons of 2008-2009 in northwestern Poland, were studied. Selenium concentration in the organs was determined spectrofluorimetrically. Mean selenium concentration was 0.06 µg/g w.w. in the liver, 0.41 µg/g w.w. in the kidneys and 0.05 µg/g w.w. in the heart and lungs. Season had a significant effect on selenium concentration in the liver, kidneys, lungs and heart. In all the organs, the highest selenium concentration was found in spring and the lowest in autumn and winter. All animals studied were deficient in selenium. The low selenium concentration in the liver or heart can disturb their function, and in the future, it may be a factor contributing to the population decline of roe deer in the northwestern part of Poland.
Simple Test Functions in Meshless Local Petrov-Galerkin Methods
NASA Technical Reports Server (NTRS)
Raju, Ivatury S.
2016-01-01
Two meshless local Petrov-Galerkin (MLPG) methods based on two different trial functions but that use a simple linear test function were developed for beam and column problems. These methods used generalized moving least squares (GMLS) and radial basis (RB) interpolation functions as trial functions. These two methods were tested on various patch test problems. Both methods passed the patch tests successfully. Then the methods were applied to various beam vibration problems and problems involving Euler and Beck's columns. Both methods yielded accurate solutions for all problems studied. The simple linear test function offers considerable savings in computing efforts as the domain integrals involved in the weak form are avoided. The two methods based on this simple linear test function method produced accurate results for frequencies and buckling loads. Of the two methods studied, the method with radial basis trial functions is very attractive as the method is simple, accurate, and robust.
Protolichesterinic acid enhances doxorubicin-induced apoptosis in HeLa cells in vitro.
Brisdelli, Fabrizia; Perilli, Mariagrazia; Sellitri, Doriana; Bellio, Pierangelo; Bozzi, Argante; Amicosante, Gianfranco; Nicoletti, Marcello; Piovano, Marisa; Celenza, Giuseppe
2016-08-01
The aim of this study was to investigate the effect of protolichesterinic acid, a lichen secondary metabolite, on anti-proliferative activity of doxorubicin in three human cancer cell lines, HeLa, SH-SY5Y and K562 cells. The data obtained from MTT assays, performed on cells treated with protolichesterinic acid and doxorubicin alone and in combination, were analysed by the median-effect method as proposed by Chou and Talalay and the Bliss independence model. Apoptosis rate was evaluated by fluorescence microscopy, caspase-3, 8 and 9 activities were detected by spectrofluorimetric analysis and protein expression of Bim, Bid, Bax and Mcl-2 was analysed by Western blotting. The interaction of protolichesterinic acid with thioesterase domain of human fatty acid synthase (hFAS) was investigated by a molecular docking study. The in vitro activity of doxorubicin against HeLa cancer cell line, but not against SH-SY5Y and K562 cells, was synergically increased by protolichesterinic acid. The increased cytotoxicity caused by protolichesterinic acid in HeLa cells was due to a pro-apoptotic effect and was associated to caspase-3, 8 and 9 activation. The simultaneous treatment for 24h with protolichesterinic acid plus doxorubicin caused an increase of Bim protein expression and the appearance of cleaved form of Bid protein. The molecular modelling analysis showed that protolichesterinic acid seemed to behave as a competitive inhibitor of hFAS. These results suggest that protolichesterinic acid could be envisaged as an useful tool against certain types of tumor cells in combination with anticancer drugs. Copyright © 2016 Elsevier Inc. All rights reserved.
Cheng, Jing; Liu, Jian-Hua; Prasanna, Govindarajan; Jing, Pu
2017-12-01
The interaction of β-Lactoglobulin (β-Lg) with cyanidin-3-O-glucoside (C3G) was characterized using fluorescence, circular dichroism spectroscopy, and docking studies under physiological conditions. Fluorescence studies showed that β-Lg has a strong binding affinity for C3G via hydrophobic interaction with the binding constant, K a , of 3.14×10 4 M -1 at 298K. The secondary structure of β-Lg displayed an increase in the major structure of β-sheet upon binding with C3G, whereas a decrease in the minor structure of α-helix was also observed. In addition, evidenced by near UV-CD, the interaction also disrupted the environments of Trp residues. The molecular docking results illustrated that both hydrogen bonding and the hydrophobic interaction are involved as an acting force during the binding process. These results may contribute to a better understanding over the enhanced physicochemical proprieties of anthocyanins due to the complexation with milk proteins. Copyright © 2017 Elsevier B.V. All rights reserved.
Modulation of biogenic amines content by poly(propylene imine) dendrimers in rats.
Ciepluch, Karol; Ziemba, Barbara; Janaszewska, Anna; Appelhans, Dietmar; Klajnert, Barbara; Bryszewska, Maria; Fogel, Wiesława Agnieszka
2012-09-01
Biogenic amines and polyamines participate in all vital organism functions, their levels being important function determinants. Studies were performed to check whether repeated administration of poly(propylene imine) (PPI) dendrimers, synthetic macromolecules with diaminobutane core, and peripheral primary amine groups, may influence the endogenous level of amines, as represented by the two of them: spermidine, a natural derivative of diaminobutane, and histamine. The experiment was carried out on Wistar rats. Fourth generation PPI dendrimer, as well as maltotriose-modified fourth generation PPI dendrimers with (a) cationic open sugar shell and (b) neutral dense sugar shell that possess a higher biocompatibility, was used. Applying the combination of column chromatography on Cellex P and spectrofluorimetric assays of o-phthaldialdehyde, the final amine condensation products were employed to analyze tissue spermidine and histamine outside the central nervous system. Furthermore, radioenzymatic assay was used to measure histamine levels in the brain. The obtained results indicate that in some tissues, the endogenous concentrations of histamine and spermidine may be affected by dendrimers depending on their dose and type of dendrimers.
Janovec, Ladislav; Sabolova, Danica; Kozurkova, Maria; Paulíkova, Helena; Kristian, Pavol; Ungvarský, Jan; Moravcíkova, Erika; Bajdichova, Maria; Podhradský, Dusan; Imrich, Jan
2007-01-01
Five novel proflavine-dithiazolidinone derivatives 4a-4e have been designed and synthesized by the reaction of dialkyl acridin-3,6-diyl dithioureas 3a-3e with methyl bromoacetate. The binding affinity of dithiazolidinone hydrochlorides 5a-5e with calf thymus DNA and plasmid (pUC19) DNA was investigated by a variety of spectroscopic techniques including UV-vis, fluorescence, and CD spectroscopy. The effects of 5a-5e on the thermal denaturation profiles of calf thymus DNA were also studied. From spectrophotometric and spectrofluorimetric titrations, the binding constants for the pUC19 DNA-drug complexes were determined (K = 6.2-2.2 x 104 M-1). In vitro cytotoxic activities of compounds 5a-5e toward murine leukemia cell line L1210 and human uterus carcinoma HeLa cells were also examined. 2',2' '-[(Acridin-3,6-diyl)diimino]-3',3' '-dipropyl-1,3-dithiazolidin-4-one hydrochloride (5b) showed the highest activity against these cells with IC50 values of 6.3 microM and 12.9 microM over the course of 72 h.
Characterization of the interactions of the pneumolysoid, Δ6 PLY, with human neutrophils in vitro.
Cockeran, R; Steel, H C; Theron, A J; Mitchell, T J; Feldman, C; Anderson, R
2011-11-08
The pneumolysin toxoid, Δ6 PLY, is a prototype pneumococcal protein vaccine candidate. However, its potentially detrimental residual pro-inflammatory interactions with human neutrophils are unknown. In the current study the effects of the toxoid (8-1000 ng/ml) have been compared with those of wild-type pneumolysin (WT/PLY, 8 ng/ml) on neutrophil cytosolic Ca(2+) fluxes, generation of leukotriene B(4) (LTB(4)), and release of matrix metalloproteinase-9 (MMP-9), using spectrofluorimetric, and ELISA procedures (LTB(4) and MMP-9) respectively. Exposure of neutrophils to WT/PLY resulted in influx of Ca(2+) and significant (P<0.05) release of MMP-9 and generation of LTB(4). However, treatment of the cells with Δ6 PLY at concentrations of up to 1000 ng/ml had only trivial effects on Ca(2+) influx and no effects on either release of MMP-9 or LTB(4) production. The observed absence of pro-inflammatory interactions of Δ6 PLY with neutrophils is clearly an important property of this pneumococcal protein vaccine candidate. Copyright © 2011 Elsevier Ltd. All rights reserved.
Esteves, Cátia I C; Raposo, M Manuela M; Costa, Susana P G
2017-05-01
Novel thienyl and bithienyl amino acids with different substituents were obtained by a multicomponent Ugi reaction between a heterocyclic aldehyde, an amine, an acid and an isocyanide. Due to the presence of the sulphur heterocycle at the side chain, these unnatural amino acids are highly emissive and bear extra electron donating atoms so they were tested for their ability to act as fluorescent probes and chemosensors in the recognition of biomedically relevant ions in acetonitrile and acetonitrile/water solutions. The results obtained from spectrophotometric/spectrofluorimetric titrations in the presence of organic and inorganic anions, and alkaline; alkaline-earth and transition metal cations indicated that the bithienyl amino acid bearing a methoxy group is a selective colorimetric chemosensor for Cu 2+ , while the other (bi)thienyl amino acids act as fluorimetric chemosensors with high sensitivity towards Fe 3+ and Cu 2+ in a metal-ligand complex with 1:2 stoichiometry. The photophysical and ion sensing properties of these amino acids confirm their potential as fluorescent probes suitable for incorporation into peptidic frameworks with chemosensory ability.
A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.
John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192).
We have developed a simple, mild extraction procedure using methanol which, when...
[Analysis on the accuracy of simple selection method of Fengshi (GB 31)].
Li, Zhixing; Zhang, Haihua; Li, Suhe
2015-12-01
To explore the accuracy of simple selection method of Fengshi (GB 31). Through the study of the ancient and modern data,the analysis and integration of the acupuncture books,the comparison of the locations of Fengshi (GB 31) by doctors from all dynasties and the integration of modern anatomia, the modern simple selection method of Fengshi (GB 31) is definite, which is the same as the traditional way. It is believed that the simple selec tion method is in accord with the human-oriented thought of TCM. Treatment by acupoints should be based on the emerging nature and the individual difference of patients. Also, it is proposed that Fengshi (GB 31) should be located through the integration between the simple method and body surface anatomical mark.
7 CFR 4280.115 - Construction planning and performing development.
Code of Federal Regulations, 2010 CFR
2010-01-01
... projects as applicable. For contracts of $200,000 or less, the simple contract method, as specified in... warranty documents. (e) Simple contract method. The simple contract method may be used for small projects... Agency and may be used only if they are customarily used in the area and protect the interest of the...
The Krylov accelerated SIMPLE(R) method for flow problems in industrial furnaces
NASA Astrophysics Data System (ADS)
Vuik, C.; Saghir, A.; Boerstoel, G. P.
2000-08-01
Numerical modeling of the melting and combustion process is an important tool in gaining understanding of the physical and chemical phenomena that occur in a gas- or oil-fired glass-melting furnace. The incompressible Navier-Stokes equations are used to model the gas flow in the furnace. The discrete Navier-Stokes equations are solved by the SIMPLE(R) pressure-correction method. In these applications, many SIMPLE(R) iterations are necessary to obtain an accurate solution. In this paper, Krylov accelerated versions are proposed: GCR-SIMPLE(R). The properties of these methods are investigated for a simple two-dimensional flow. Thereafter, the efficiencies of the methods are compared for three-dimensional flows in industrial glass-melting furnaces. Copyright
Haider, Saida; Saleem, Sadia; Tabassum, Saiqa; Khaliq, Saima; Shamim, Saima; Batool, Zehra; Parveen, Tahira; Inam, Qurat-ul-ain; Haleem, Darakhshan J
2013-03-01
Lead toxicity is known to induce a broad range of physiological, biochemical and behavioral dysfunctions that may result in adverse effects on several organs, including the central nervous system. Long-term exposure to low levels of lead (Pb(2+)) has been shown to produce behavioral deficits in rodents and humans by affecting hypothalamic-pituitary-adrenal (HPA) axis. These deficits are thought to be associated with altered brain monoamine neurotransmission and due to changes in glucocorticoids levels. This study was designed to investigate the effects of Pb(2+)exposure on growth rate, locomotor activity, anxiety, depression, plasma corticosterone and brain serotonin (5-HT) levels in rats. Rats were exposed to lead in drinking water (500 ppm; lead acetate) for 5 weeks. The assessment of depression was done using the forced swimming test (FST). Estimation of brain 5-HT was determined by high-performance liquid chromatography with electrochemical detection. Plasma corticosterone was determined by spectrofluorimetric method. The present study showed that long term exposure to Pb(2+) significantly decreased the food intake followed by the decrease in growth rate in Pb(2+)exposed rats as compared to control group. No significant changes in open field activity were observed following Pb(2+)exposure while significant increase in anxiogenic effect was observed. Increased plasma corticosterone and decreased 5-HT levels were exhibited by Pb(2+)exposed rats as compared to controls. A significant increase in depressive like symptoms was exhibited by Pb(2+)exposed rats as compared to control rats. The results are discussed in the context of Pb(2+) inducing a stress-like response in rats leading to changes in plasma corticosterone and brain 5-HT levels via altering tryptophan pyrrolase activity.
Simple-MSSM: a simple and efficient method for simultaneous multi-site saturation mutagenesis.
Cheng, Feng; Xu, Jian-Miao; Xiang, Chao; Liu, Zhi-Qiang; Zhao, Li-Qing; Zheng, Yu-Guo
2017-04-01
To develop a practically simple and robust multi-site saturation mutagenesis (MSSM) method that enables simultaneously recombination of amino acid positions for focused mutant library generation. A general restriction enzyme-free and ligase-free MSSM method (Simple-MSSM) based on prolonged overlap extension PCR (POE-PCR) and Simple Cloning techniques. As a proof of principle of Simple-MSSM, the gene of eGFP (enhanced green fluorescent protein) was used as a template gene for simultaneous mutagenesis of five codons. Forty-eight randomly selected clones were sequenced. Sequencing revealed that all the 48 clones showed at least one mutant codon (mutation efficiency = 100%), and 46 out of the 48 clones had mutations at all the five codons. The obtained diversities at these five codons are 27, 24, 26, 26 and 22, respectively, which correspond to 84, 75, 81, 81, 69% of the theoretical diversity offered by NNK-degeneration (32 codons; NNK, K = T or G). The enzyme-free Simple-MSSM method can simultaneously and efficiently saturate five codons within one day, and therefore avoid missing interactions between residues in interacting amino acid networks.
Rao, V Venkat; Ningshen, Thuirei Jacob; Chaitanya, R K; Senthilkumaran, B; Dutta-Gupta, Aparna
2016-01-01
In the present study, a riboflavin-binding hexamerin (RbHex) was cloned and characterized from the larval fat body of Corcyra cephalonica. The complete cDNA (2121bp) encodes a 706-amino acid protein with a molecular mass ~82kDa. Expression of RbHex 82 was predominant in fat body among larval tissues. Further, it is prominently expressed during the last instar larval development. Homology modeling and docking studies predicted riboflavin binding site of the hexamerin. Spectrofluorimetric analysis further confirmed riboflavin release from the hexamerin fraction. Quantitative RT-PCR studies demonstrated hormonal regulation of RbHex 82. 20-Hydroxyecdysone (20HE) had a stimulatory effect on its transcription whereas JH alone did not show any effect. However, JH in the presence of 20HE maintains the RbHex 82 expression which indicates the JH's role as a status quo factor. This study is the first to report the characterization of riboflavin-binding hexamerin in a lepidopteran pest. Further, the possibility of RbHex 82 as a pest control target is discussed. Copyright © 2016 Elsevier Inc. All rights reserved.
Bollimpelli, V Satish; Kumar, Prashant; Kumari, Sonali; Kondapi, Anand K
2016-05-01
Curcumin is known to have neuroprotective role and possess antioxidant, anti-inflammatory activities. Rotenone, a flavonoid induced neurotoxicity in dopaminergic cells is being widely studied in Parkinson's Disease (PD) research. In the present study, curcumin loaded lactoferrin nano particles prepared by sol-oil chemistry were used to protect dopaminergic cell line SK-N-SH against rotenone induced neurotoxicity. These curcumin loaded nano particles were of 43-60 nm diameter size and around 100 nm hydrodynamic size as assessed by transmission electron microscopy, atomic force microscopy and dynamic light scattering analysis respectively. The encapsulation efficiency was 61.3% ± 2.4%. Cellular uptake of curcumin through these nano particles was confirmed by confocal imaging and spectrofluorimetric analysis. The curcumin loaded lactoferrin nanoparticles showed greater intracellular drug uptake, sustained retention and greater neuroprotection than soluble counterpart. Neuroprotective activity was characterized through viability assays and by estimating ROS levels. Furthermore rotenone induced PD like features were characterized by decrease in tyrosine hydroxylase expression and increase in α-synuclein expression. Taken together curcumin loaded lactoferrin nanoparticles could be a promising drug delivery strategy against neurotoxicity in dopaminergic neurons. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhai, Qiu-ge; Guo, Peng; Zhou, Lin; Liu, Yan-ming
2014-08-01
Graphene oxide was prepared by the modified Hummers method and characterized by field emission scanning electron microscopy. The interaction of graphene with methylene blue was studied by UV absorption, the intensity of two main absorption peaks of methylene blue decreased significantly after the fluorescence was quenched, and the energy transfer didn't occur because the overlap of the absorption spectrum of GO and the emission spectrum of MB is too small. Therefore, the fluorescence quenching of MB and GO was static. When adding a certain amount of Bi3+ in the graphene-methylene blue system, Bi3+ replaces the methylene blue from the graphene-methylene blue complexes because Bi3+ has the smaller volume and is more positively charged. The methylene blue therefore dissociates from the GO-MB complexes, resulting in the recovery of fluorescence of the system. Furthermore, the fluorescence of the system increases with the increase in the amount of Bi3+ due to the enhanced amount of MB in the system. A novel spectrofluorimetric method was therefore developed for the sensitive determination of Bi3+. Some parameters including the concentration of methylene blue, the amount of graphene oxide, the amount of nitric acid and the sequence of reagent adding were optimized to obtain higher sensitivity. The fluorescence of the system was detected at an emission wavelength of 667 nm with excitation at 690 nm. Under the optimized conditions, the concentration of Bi3+ showed good linear relationships with the fluorescence intensity in the range of 0.5-100 micromol x L(-1), with correlation coefficients of r = 0.9955. The limits of detection for Bi3+ was 1.0 x 10(-8) mol x L(-1) (S/N=3). The selectivity of the proposed method was evaluated and the results showed that 1000-fold K+, Ca+, Na+, Mg2+, Cu2+; 100-fold Fe3+, Be2+, SiO2- Al3+, Ni2+, Sb3+, NO3-, Cl-, F-, and 20-fold Pb2+, Hg2+, Cd2+ had negligible interference with the determination of Bi3+. The method has advantages of sensitivity, rapidness and low cost. It was used for the determination of Bi3+ in environmental water samples inclu- ding pond water, rain water and sewage water with recoveries of 93.4%-105.2%.
A simple finite element method for non-divergence form elliptic equation
Mu, Lin; Ye, Xiu
2017-03-01
Here, we develop a simple finite element method for solving second order elliptic equations in non-divergence form by combining least squares concept with discontinuous approximations. This simple method has a symmetric and positive definite system and can be easily analyzed and implemented. We could have also used general meshes with polytopal element and hanging node in the method. We prove that our finite element solution approaches to the true solution when the mesh size approaches to zero. Numerical examples are tested that demonstrate the robustness and flexibility of the method.
A simple finite element method for non-divergence form elliptic equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mu, Lin; Ye, Xiu
Here, we develop a simple finite element method for solving second order elliptic equations in non-divergence form by combining least squares concept with discontinuous approximations. This simple method has a symmetric and positive definite system and can be easily analyzed and implemented. We could have also used general meshes with polytopal element and hanging node in the method. We prove that our finite element solution approaches to the true solution when the mesh size approaches to zero. Numerical examples are tested that demonstrate the robustness and flexibility of the method.
Recognizing simple polyhedron from a perspective drawing
NASA Astrophysics Data System (ADS)
Zhang, Guimei; Chu, Jun; Miao, Jun
2009-10-01
Existed methods can't be used for recognizing simple polyhedron. In this paper, three problems are researched. First, a method for recognizing triangle and quadrilateral is introduced based on geometry and angle constraint. Then Attribute Relation Graph (ARG) is employed to describe simple polyhedron and line drawing. Last, a new method is presented to recognize simple polyhedron from a line drawing. The method filters the candidate database before matching line drawing and model, thus the recognition efficiency is improved greatly. We introduced the geometrical characteristics and topological characteristics to describe each node of ARG, so the algorithm can not only recognize polyhedrons with different shape but also distinguish between polyhedrons with the same shape but with different sizes and proportions. Computer simulations demonstrate the effectiveness of the method preliminarily.
Bootstrap Methods: A Very Leisurely Look.
ERIC Educational Resources Information Center
Hinkle, Dennis E.; Winstead, Wayland H.
The Bootstrap method, a computer-intensive statistical method of estimation, is illustrated using a simple and efficient Statistical Analysis System (SAS) routine. The utility of the method for generating unknown parameters, including standard errors for simple statistics, regression coefficients, discriminant function coefficients, and factor…
Combinational Reasoning of Quantitative Fuzzy Topological Relations for Simple Fuzzy Regions
Liu, Bo; Li, Dajun; Xia, Yuanping; Ruan, Jian; Xu, Lili; Wu, Huanyi
2015-01-01
In recent years, formalization and reasoning of topological relations have become a hot topic as a means to generate knowledge about the relations between spatial objects at the conceptual and geometrical levels. These mechanisms have been widely used in spatial data query, spatial data mining, evaluation of equivalence and similarity in a spatial scene, as well as for consistency assessment of the topological relations of multi-resolution spatial databases. The concept of computational fuzzy topological space is applied to simple fuzzy regions to efficiently and more accurately solve fuzzy topological relations. Thus, extending the existing research and improving upon the previous work, this paper presents a new method to describe fuzzy topological relations between simple spatial regions in Geographic Information Sciences (GIS) and Artificial Intelligence (AI). Firstly, we propose a new definition for simple fuzzy line segments and simple fuzzy regions based on the computational fuzzy topology. And then, based on the new definitions, we also propose a new combinational reasoning method to compute the topological relations between simple fuzzy regions, moreover, this study has discovered that there are (1) 23 different topological relations between a simple crisp region and a simple fuzzy region; (2) 152 different topological relations between two simple fuzzy regions. In the end, we have discussed some examples to demonstrate the validity of the new method, through comparisons with existing fuzzy models, we showed that the proposed method can compute more than the existing models, as it is more expressive than the existing fuzzy models. PMID:25775452
Simple, Low-Cost Data Collection Methods for Agricultural Field Studies.
ERIC Educational Resources Information Center
Koenig, Richard T.; Winger, Marlon; Kitchen, Boyd
2000-01-01
Summarizes relatively simple and inexpensive methods for collecting data from agricultural field studies. Describes methods involving on-farm testing, crop yield measurement, quality evaluations, weed control effectiveness, plant nutrient status, and other measures. Contains 29 references illustrating how these methods were used to conduct…
A simple finite element method for the Stokes equations
Mu, Lin; Ye, Xiu
2017-03-21
The goal of this paper is to introduce a simple finite element method to solve the Stokes equations. This method is in primal velocity-pressure formulation and is so simple such that both velocity and pressure are approximated by piecewise constant functions. Implementation issues as well as error analysis are investigated. A basis for a divergence free subspace of the velocity field is constructed so that the original saddle point problem can be reduced to a symmetric and positive definite system with much fewer unknowns. The numerical experiments indicate that the method is accurate.
A simple finite element method for the Stokes equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mu, Lin; Ye, Xiu
The goal of this paper is to introduce a simple finite element method to solve the Stokes equations. This method is in primal velocity-pressure formulation and is so simple such that both velocity and pressure are approximated by piecewise constant functions. Implementation issues as well as error analysis are investigated. A basis for a divergence free subspace of the velocity field is constructed so that the original saddle point problem can be reduced to a symmetric and positive definite system with much fewer unknowns. The numerical experiments indicate that the method is accurate.
The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures
NASA Astrophysics Data System (ADS)
Stephenson, W. Kirk
2009-08-01
A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes.
Airtightness the simple(CS) way
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, S.
Builders who might buck against such time consuming air sealing methods as polyethylene wrap and the airtight drywall approach (ADA) may respond better to current strategies. One such method, called SimpleCS, has proven especially effective. SimpleCS, pronounced simplex, stands for simple caulk and seal. A modification of the ADA, SimpleCS is an air-sealing management tool, a simplified systems approach to building tight homes. The system address the crucial question of when and by whom various air sealing steps should be done. It avoids the problems that often occur when later contractors cut open polyethylene wrap to drill holes in themore » drywall. The author describes how SimpleCS works, and the cost and training involved.« less
The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures
ERIC Educational Resources Information Center
Stephenson, W. Kirk
2009-01-01
A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)
Monosodium glutamate for simple photometric iron analysis
NASA Astrophysics Data System (ADS)
Prasetyo, E.
2018-01-01
Simple photometric method for iron analysis using monosodium glutamate (MSG) was proposed. The method could be used as an alternative method, which was technically simple, economic, quantitative, readily available, scientifically sound and environmental friendly. Rapid reaction of iron (III) with glutamate in sodium chloride-hydrochloric acid buffer (pH 2) to form red-brown complex was served as a basis in the photometric determination, which obeyed the range of iron (III) concentration 1.6 - 80 µg/ml. This method could be applied to determine iron concentration in soil with satisfactory results (accuracy and precision) compared to other photometric and atomic absorption spectrometry results.
A comparison of methods for teaching receptive labeling to children with autism spectrum disorders.
Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N
2011-01-01
Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed.
Jin, Hui; Lao, Yong Min; Zhou, Jin; Zhang, Huai Jin; Cai, Zhong Hua
2017-03-10
A simple ultra-high-pressure liquid chromatography (UHPLC) method for rapidly and simultaneously identifying thirteen carotenoids in Haematococcus pluvialis was developed in this study. The method is capable of effectively separating two astaxanthin isomers, two ζ-carotene isomers, and three phytoene isomers on two simple C18 columns within 9 and 12min only by using methanol and acetonitrile, respectively. To our best knowledge, this is the rapidest method for these carotenoid isomers, currently. Using this method, carotenoid profiling in the astaxanthin-accumulating H. pluvialis under environmental stresses was successfully carried out. Results indicated that carotenoid biosynthesis was differentially perturbed by environmental stresses, indicating that this simple and rapid method is suitable to not only bacterial but also algal samples, with potential applications for a wide range of samples from plant to animal. Finally, possible reasons for the elution order of carotenoids were studied. Copyright © 2017 Elsevier B.V. All rights reserved.
Rubio, L; Ortiz, M C; Sarabia, L A
2014-04-11
A non-separative, fast and inexpensive spectrofluorimetric method based on the second order calibration of excitation-emission fluorescence matrices (EEMs) was proposed for the determination of carbaryl, carbendazim and 1-naphthol in dried lime tree flowers. The trilinearity property of three-way data was used to handle the intrinsic fluorescence of lime flowers and the difference in the fluorescence intensity of each analyte. It also made possible to identify unequivocally each analyte. Trilinearity of the data tensor guarantees the uniqueness of the solution obtained through parallel factor analysis (PARAFAC), so the factors of the decomposition match up with the analytes. In addition, an experimental procedure was proposed to identify, with three-way data, the quenching effect produced by the fluorophores of the lime flowers. This procedure also enabled the selection of the adequate dilution of the lime flowers extract to minimize the quenching effect so the three analytes can be quantified. Finally, the analytes were determined using the standard addition method for a calibration whose standards were chosen with a D-optimal design. The three analytes were unequivocally identified by the correlation between the pure spectra and the PARAFAC excitation and emission spectral loadings. The trueness was established by the accuracy line "calculated concentration versus added concentration" in all cases. Better decision limit values (CCα), in x0=0 with the probability of false positive fixed at 0.05, were obtained for the calibration performed in pure solvent: 2.97 μg L(-1) for 1-naphthol, 3.74 μg L(-1) for carbaryl and 23.25 μg L(-1) for carbendazim. The CCα values for the second calibration carried out in matrix were 1.61, 4.34 and 51.75 μg L(-1) respectively; while the values obtained considering only the pure samples as calibration set were: 2.65, 8.61 and 28.7 μg L(-1), respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
Rendering the "Not-So-Simple" Pendulum Experimentally Accessible.
ERIC Educational Resources Information Center
Jackson, David P.
1996-01-01
Presents three methods for obtaining experimental data related to acceleration of a simple pendulum. Two of the methods involve angular position measurements and the subsequent calculation of the acceleration while the third method involves a direct measurement of the acceleration. Compares these results with theoretical calculations and…
A Simple Method for Calculating Clebsch-Gordan Coefficients
ERIC Educational Resources Information Center
Klink, W. H.; Wickramasekara, S.
2010-01-01
This paper presents a simple method for calculating Clebsch-Gordan coefficients for the tensor product of two unitary irreducible representations (UIRs) of the rotation group. The method also works for multiplicity-free irreducible representations appearing in the tensor product of any number of UIRs of the rotation group. The generalization to…
Simple and Clear Proofs of Stirling's Formula
ERIC Educational Resources Information Center
Niizeki, Shozo; Araki, Makoto
2010-01-01
The purpose of our article is to show two simpler and clearer methods of proving Stirling's formula than the traditional and conventional ones. The distinction of our method is to use the simple trapezoidal formula.
Isolation and N-terminal sequencing of a novel cadmium-binding protein from Boletus edulis
NASA Astrophysics Data System (ADS)
Collin-Hansen, C.; Andersen, R. A.; Steinnes, E.
2003-05-01
A Cd-binding protein was isolated from the popular edible mushroom Boletus edulis, which is a hyperaccumulator of both Cd and Hg. Wild-growing samples of B. edulis were collected from soils rich in Cd. Cd radiotracer was added to the crude protein preparation obtained from ethanol precipitation of heat-treated cytosol. Proteins were then further separated in two consecutive steps; gel filtration and anion exchange chromatography. In both steps the Cd radiotracer profile showed only one distinct peak, which corresponded well with the profiles of endogenous Cd obtained by atomic absorption spectrophotometry (AAS). Concentrations of the essential elements Cu and Zn were low in the protein fractions high in Cd. N-terminal sequencing performed on the Cd-binding protein fractions revealed a protein with a novel amino acid sequence, which contained aromatic amino acids as well as proline. Both the N-terminal sequencing and spectrofluorimetric analysis with EDTA and ABD-F (4-aminosulfonyl-7-fluoro-2, 1, 3-benzoxadiazole) failed to detect cysteine in the Cd-binding fractions. These findings conclude that the novel protein does not belong to the metallothionein family. The results suggest a role for the protein in Cd transport and storage, and they are of importance in view of toxicology and food chemistry, but also for environmental protection.
Chow, Cheuk-Fai
2012-11-01
Adenine is an important bio-molecule that plays many crucial roles in food safety and biomedical diagnostics. Differentiating adenine from a mixture of adenosine and other nucleic bases (guanine, thymine, cytosine, and uracil) is particularly important for both biological and clinical applications. A neutral Zn(II) metallosupramolecular polymer based on acyl hydrazone derived coordination centres (P1) were generated through self-assembly polymerization. It is a linear coordination polymer that behaves like self-standing film. The synthesis, (1)H-NMR characterization, and spectroscopic properties of this supramolecular material are reported. P1 was found to be a chemosensor specific to adenine, with a luminescent enhancement. The binding properties of P1 with common nucleic bases and nucleosides reveal that this supramolecular polymer is very selective to adenine molecules (~20 to 420 times more selectivity than other nucleic bases). The formation constant (K) of P1 to adenine was found to be log K = 4.10 ± 0.02. This polymeric chemosensor produces a specific response to adenine down to 90 ppb. Spectrofluorimetric and (1)H-NMR titration studies showed that the P1 polymer allows each Zn(II) coordination centre to bind to two adenine molecules through hydrogen bonding with their imine and hydrazone protons.
Method for estimating the morphological significance of simple forms of crystals from X-ray data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Treivus, E. B., E-mail: sbobr1@bk.ru
2010-09-15
When developing V.I. Mikheev and I.I. Shafranovskii's method for estimating the morphological significance of faces of different simple forms from X-ray reflection intensities, a way to approximately evaluate the morphological significance of simple forms on crystals from the structure amplitudes of the corresponding atomic planes is proposed. The potential for this approach is demonstrated by the examples of marcasite and zircon.
A Novel Method for Discovering Fuzzy Sequential Patterns Using the Simple Fuzzy Partition Method.
ERIC Educational Resources Information Center
Chen, Ruey-Shun; Hu, Yi-Chung
2003-01-01
Discusses sequential patterns, data mining, knowledge acquisition, and fuzzy sequential patterns described by natural language. Proposes a fuzzy data mining technique to discover fuzzy sequential patterns by using the simple partition method which allows the linguistic interpretation of each fuzzy set to be easily obtained. (Author/LRW)
A COMPARISON OF METHODS FOR TEACHING RECEPTIVE LABELING TO CHILDREN WITH AUTISM SPECTRUM DISORDERS
Grow, Laura L; Carr, James E; Kodak, Tiffany M; Jostad, Candice M; Kisamore, April N
2011-01-01
Many early intervention curricular manuals recommend teaching auditory-visual conditional discriminations (i.e., receptive labeling) using the simple-conditional method in which component simple discriminations are taught in isolation and in the presence of a distracter stimulus before the learner is required to respond conditionally. Some have argued that this procedure might be susceptible to faulty stimulus control such as stimulus overselectivity (Green, 2001). Consequently, there has been a call for the use of alternative teaching procedures such as the conditional-only method, which involves conditional discrimination training from the onset of intervention. The purpose of the present study was to compare the simple-conditional and conditional-only methods for teaching receptive labeling to 3 young children diagnosed with autism spectrum disorders. The data indicated that the conditional-only method was a more reliable and efficient teaching procedure. In addition, several error patterns emerged during training using the simple-conditional method. The implications of the results with respect to current teaching practices in early intervention programs are discussed. PMID:21941380
Grow, Laura L; Kodak, Tiffany; Carr, James E
2014-01-01
Previous research has demonstrated that the conditional-only method (starting with a multiple-stimulus array) is more efficient than the simple-conditional method (progressive incorporation of more stimuli into the array) for teaching receptive labeling to children with autism spectrum disorders (Grow, Carr, Kodak, Jostad, & Kisamore,). The current study systematically replicated the earlier study by comparing the 2 approaches using progressive prompting with 2 boys with autism. The results showed that the conditional-only method was a more efficient and reliable teaching procedure than the simple-conditional method. The results further call into question the practice of teaching simple discriminations to facilitate acquisition of conditional discriminations. © Society for the Experimental Analysis of Behavior.
A simple level set method for solving Stefan problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, S.; Merriman, B.; Osher, S.
1997-07-15
Discussed in this paper is an implicit finite difference scheme for solving a heat equation and a simple level set method for capturing the interface between solid and liquid phases which are used to solve Stefan problems.
A simple finite element method for linear hyperbolic problems
Mu, Lin; Ye, Xiu
2017-09-14
Here, we introduce a simple finite element method for solving first order hyperbolic equations with easy implementation and analysis. Our new method, with a symmetric, positive definite system, is designed to use discontinuous approximations on finite element partitions consisting of arbitrary shape of polygons/polyhedra. Error estimate is established. Extensive numerical examples are tested that demonstrate the robustness and flexibility of the method.
A simple finite element method for linear hyperbolic problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mu, Lin; Ye, Xiu
Here, we introduce a simple finite element method for solving first order hyperbolic equations with easy implementation and analysis. Our new method, with a symmetric, positive definite system, is designed to use discontinuous approximations on finite element partitions consisting of arbitrary shape of polygons/polyhedra. Error estimate is established. Extensive numerical examples are tested that demonstrate the robustness and flexibility of the method.
Analysis of pre-service physics teacher skills designing simple physics experiments based technology
NASA Astrophysics Data System (ADS)
Susilawati; Huda, C.; Kurniawan, W.; Masturi; Khoiri, N.
2018-03-01
Pre-service physics teacher skill in designing simple experiment set is very important in adding understanding of student concept and practicing scientific skill in laboratory. This study describes the skills of physics students in designing simple experiments based technologicall. The experimental design stages include simple tool design and sensor modification. The research method used is descriptive method with the number of research samples 25 students and 5 variations of simple physics experimental design. Based on the results of interviews and observations obtained the results of pre-service physics teacher skill analysis in designing simple experimental physics charged technology is good. Based on observation result, pre-service physics teacher skill in designing simple experiment is good while modification and sensor application are still not good. This suggests that pre-service physics teacher still need a lot of practice and do experiments in designing physics experiments using sensor modifications. Based on the interview result, it is found that students have high enough motivation to perform laboratory activities actively and students have high curiosity to be skilled at making simple practicum tool for physics experiment.
New Tools to Prepare ACE Cross-section Files for MCNP Analytic Test Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Forrest B.
Monte Carlo calculations using one-group cross sections, multigroup cross sections, or simple continuous energy cross sections are often used to: (1) verify production codes against known analytical solutions, (2) verify new methods and algorithms that do not involve detailed collision physics, (3) compare Monte Carlo calculation methods with deterministic methods, and (4) teach fundamentals to students. In this work we describe 2 new tools for preparing the ACE cross-section files to be used by MCNP ® for these analytic test problems, simple_ace.pl and simple_ace_mg.pl.
A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.
Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste
2018-02-01
To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV% < 10%), whatever the considered method. The mechanical variables ([Formula: see text], [Formula: see text]) measured with the 2 methods and all the variables extrapolated from the F-v relationships were strongly correlated (r 2 > .80, P < .001). The practical differences between the methods for the extrapolated mechanical parameters were all <5%, indicating very probably no differences. The findings suggest that the simple computation method used here provides valid and reliable information on force and velocity produced during ballistic bench press, in line with that observed in laboratory conditions. This simple method is thus a practical tool, requiring only 3 simple parameters (upper-limb mass, barbell flight height, and push-off distance).
A Simple Microsoft Excel Method to Predict Antibiotic Outbreaks and Underutilization.
Miglis, Cristina; Rhodes, Nathaniel J; Avedissian, Sean N; Zembower, Teresa R; Postelnick, Michael; Wunderink, Richard G; Sutton, Sarah H; Scheetz, Marc H
2017-07-01
Benchmarking strategies are needed to promote the appropriate use of antibiotics. We have adapted a simple regressive method in Microsoft Excel that is easily implementable and creates predictive indices. This method trends consumption over time and can identify periods of over- and underuse at the hospital level. Infect Control Hosp Epidemiol 2017;38:860-862.
NASA Astrophysics Data System (ADS)
Magdy, Nancy; Ayad, Miriam F.
2015-02-01
Two simple, accurate, precise, sensitive and economic spectrophotometric methods were developed for the simultaneous determination of Simvastatin and Ezetimibe in fixed dose combination products without prior separation. The first method depends on a new chemometrics-assisted ratio spectra derivative method using moving window polynomial least square fitting method (Savitzky-Golay filters). The second method is based on a simple modification for the ratio subtraction method. The suggested methods were validated according to USP guidelines and can be applied for routine quality control testing.
Application of 2-Aminothiazoline-4-carboxylic Acid as a Forensic Marker of Cyanide Exposure.
Rużycka, Monika; Giebułtowicz, Joanna; Fudalej, Marcin; Krajewski, Paweł; Wroczyński, Piotr
2017-02-20
Cyanides are infamous for their highly poisonous properties. Accidental cyanide poisoning occurs frequently, but occasionally, intentional poisonings also occur. Inhalation of fumes generated by fire may also cause cyanide poisoning. There are many limitations in direct analysis of cyanide. 2-Aminothiazoline-4-carboxylic acid (ATCA), a cyanide metabolite, seems to be the only surrogate that is being used in the detection of cyanide because of its stability and its cyanide-dependent quality in a biological matrix. Unfortunately, toxicokinetic studies on diverse animal models suggest significant interspecies differences; therefore, the attempt to extrapolate animal models to human models may be unsuccessful. The aim of the present study was to evaluate the use of ATCA as a forensic marker of cyanide exposure. For this purpose, post-mortem materials (blood and organs) from fire victims (n = 32) and cyanide-poisoned persons (n = 3) were collected. The distribution of ATCA in organs and its thermal stability were evaluated. The variability of cyanides in a putrid sample and in the context of their long-term and higher temperature stability was established. The presence of ATCA was detected by using an LC-MS/MS method and that of cyanide was detected spectrofluorimetrically. This is the first report on the endogenous ATCA concentrations and the determination of ATCA distribution in tissues of fire victims and cyanide-poisoned persons. It was found that blood and heart had the highest ATCA concentrations. ATCA was observed to be thermally stable even at 90 °C. Even though the cyanide concentration was not elevated in putrid samples, it was unstable during long-term storage and at higher temperature, as expected. The relationship between ATCA and cyanides was also observed. Higher ATCA concentrations were related to increased levels of cyanide in blood and organs (less prominent). ATCA seems to be a reliable forensic marker of exposure to lethal doses of cyanide.
A simple method for calculating the characteristics of the Dutch roll motion of an airplane
NASA Technical Reports Server (NTRS)
Klawans, Bernard B
1956-01-01
A simple method for calculating the characteristics of the Dutch roll motion of an airplane is obtained by arranging the lateral equations of motion in such form and order that an iterative process is quickly convergent.
Directions for computational mechanics in automotive crashworthiness
NASA Technical Reports Server (NTRS)
Bennett, James A.; Khalil, T. B.
1993-01-01
The automotive industry has used computational methods for crashworthiness since the early 1970's. These methods have ranged from simple lumped parameter models to full finite element models. The emergence of the full finite element models in the mid 1980's has significantly altered the research direction. However, there remains a need for both simple, rapid modeling methods and complex detailed methods. Some directions for continuing research are discussed.
Directions for computational mechanics in automotive crashworthiness
NASA Astrophysics Data System (ADS)
Bennett, James A.; Khalil, T. B.
1993-08-01
The automotive industry has used computational methods for crashworthiness since the early 1970's. These methods have ranged from simple lumped parameter models to full finite element models. The emergence of the full finite element models in the mid 1980's has significantly altered the research direction. However, there remains a need for both simple, rapid modeling methods and complex detailed methods. Some directions for continuing research are discussed.
Simple method for determination of patulin production by Penicillium griseofulvum Dierckx.
Torres, M; Sanchis, V; Riba, M; Canela, R
1986-01-01
Patulin production by Penicillium griseofulvum was monitored with Sep-Pak cartridges and high-pressure liquid chromatography. Determination and quantification of this metabolite proved to be very simple, and our method saved time and a large amount of organic solvents. PMID:3513700
A conceptually and computationally simple method for the definition, display, quantification, and comparison of the shapes of three-dimensional mathematical molecular models is presented. Molecular or solvent-accessible volume and surface area can also be calculated. Algorithms, ...
A new technique for correction of simple congenital earlobe clefts: diametric hinge flaps method.
Qing, Yong; Cen, Ying; Xu, Xuewen; Chen, Junjie
2013-06-01
The earlobe plays an important part in the aesthetic appearance of the auricle. Congenital cleft earlobe may vary considerably in severity from a simple notching to extensive tissue deficiency. Most patients with cleft earlobe require surgical correction because of abnormal appearance. In this article, a new surgical technique for correcting congenital simple cleft earlobe using diametric hinge flaps is introduced. We retrospectively reviewed 4 patients diagnosed with congenital cleft earlobe between 2008 and 2010. All of them received this new surgical method. The patients were followed up from 3 to 6 months. All patients attained relatively full bodied earlobes with smooth contours, inconspicuous scars, and found their reconstructed earlobes to be aesthetically satisfactory. One patient experienced hypoesthesia in the area operated on, but recovered 3 months later. No other complications were noted. This simple method not only makes full use of the surrounding tissues to reconstruct full bodied earlobes but also avoids small notch formation caused by the linear scar contraction sometimes seen when using more traditional methods.
Harada, Ichiro; Kim, Sung-Gon; Cho, Chong Su; Kurosawa, Hisashi; Akaike, Toshihiro
2007-01-01
In this study, a simple combined method consisting of floating and anchored collagen gel in a ligament or tendon equivalent culture system was used to produce the oriented fibrils in fibroblast-populated collagen matrices (FPCMs) during the remodeling and contraction of the collagen gel. Orientation of the collagen fibrils along single axis occurred over the whole area of the floating section and most of the fibroblasts were elongated and aligned along the oriented collagen fibrils, whereas no significant orientation of fibrils was observed in normally contracted FPCMs by the floating method. Higher elasticity and enhanced mechanical strength were obtained using our simple method compared with normally contracted floating FPCMs. The Young's modulus and the breaking point of the FPCMs were dependent on the initial cell densities. This simple method will be applied as a convenient bioreactor to study cellular processes of the fibroblasts in the tissues with highly oriented fibrils such as ligaments or tendons. (c) 2006 Wiley Periodicals, Inc.
Umesh P. Agarwal; Richard S. Reiner; Sally A. Ralph
2010-01-01
Two new methods based on FTâRaman spectroscopy, one simple, based on band intensity ratio, and the other using a partial least squares (PLS) regression model, are proposed to determine cellulose I crystallinity. In the simple method, crystallinity in cellulose I samples was determined based on univariate regression that was first developed using the Raman band...
A Simple Method to Determine the "R" or "S" Configuration of Molecules with an Axis of Chirality
ERIC Educational Resources Information Center
Wang, Cunde; Wu, Weiming
2011-01-01
A simple method for the "R" or "S" designation of molecules with an axis of chirality is described. The method involves projection of the substituents along the chiral axis, utilizes the Cahn-Ingold-Prelog sequence rules in assigning priority to the substituents, is easy to use, and has broad applicability. (Contains 5 figures.)
ERIC Educational Resources Information Center
Bawaneh, Ali Khalid Ali; Nurulazam Md Zain, Ahmad; Salmiza, Saleh
2011-01-01
The purpose of this study was to investigate the effect of Herrmann Whole Brain Teaching Method over conventional teaching method on eight graders in their understanding of simple electric circuits in Jordan. Participants (N = 273 students; M = 139, F = 134) were randomly selected from Bani Kenanah region-North of Jordan and randomly assigned to…
Kovács, G. S.; Tárnoky, K. E.
1960-01-01
A simple and rapid procedure has been developed for the complexometric titration of serum calcium and magnesium using “plasmocorinth B” as indicator. Both determinations can be carried out from the same 0.5 ml. sample. The method is in good agreement with the established calcium and magnesium methods. PMID:14411396
NASA Astrophysics Data System (ADS)
Kwon, Ki-Won; Cho, Yongsoo
This letter presents a simple joint estimation method for residual frequency offset (RFO) and sampling frequency offset (STO) in OFDM-based digital video broadcasting (DVB) systems. The proposed method selects a continual pilot (CP) subset from an unsymmetrically and non-uniformly distributed CP set to obtain an unbiased estimator. Simulation results show that the proposed method using a properly selected CP subset is unbiased and performs robustly.
Simple algorithm for improved security in the FDDI protocol
NASA Astrophysics Data System (ADS)
Lundy, G. M.; Jones, Benjamin
1993-02-01
We propose a modification to the Fiber Distributed Data Interface (FDDI) protocol based on a simple algorithm which will improve confidential communication capability. This proposed modification provides a simple and reliable system which exploits some of the inherent security properties in a fiber optic ring network. This method differs from conventional methods in that end to end encryption can be facilitated at the media access control sublayer of the data link layer in the OSI network model. Our method is based on a variation of the bit stream cipher method. The transmitting station takes the intended confidential message and uses a simple modulo two addition operation against an initialization vector. The encrypted message is virtually unbreakable without the initialization vector. None of the stations on the ring will have access to both the encrypted message and the initialization vector except the transmitting and receiving stations. The generation of the initialization vector is unique for each confidential transmission and thus provides a unique approach to the key distribution problem. The FDDI protocol is of particular interest to the military in terms of LAN/MAN implementations. Both the Army and the Navy are considering the standard as the basis for future network systems. A simple and reliable security mechanism with the potential to support realtime communications is a necessary consideration in the implementation of these systems. The proposed method offers several advantages over traditional methods in terms of speed, reliability, and standardization.
A simple three dimensional wide-angle beam propagation method
NASA Astrophysics Data System (ADS)
Ma, Changbao; van Keuren, Edward
2006-05-01
The development of three dimensional (3-D) waveguide structures for chip scale planar lightwave circuits (PLCs) is hampered by the lack of effective 3-D wide-angle (WA) beam propagation methods (BPMs). We present a simple 3-D wide-angle beam propagation method (WA-BPM) using Hoekstra’s scheme along with a new 3-D wave equation splitting method. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation and comparing them with analytical solutions.
A simple three dimensional wide-angle beam propagation method.
Ma, Changbao; Van Keuren, Edward
2006-05-29
The development of three dimensional (3-D) waveguide structures for chip scale planar lightwave circuits (PLCs) is hampered by the lack of effective 3-D wide-angle (WA) beam propagation methods (BPMs). We present a simple 3-D wide-angle beam propagation method (WA-BPM) using Hoekstra's scheme along with a new 3-D wave equation splitting method. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation and comparing them with analytical solutions.
On an image reconstruction method for ECT
NASA Astrophysics Data System (ADS)
Sasamoto, Akira; Suzuki, Takayuki; Nishimura, Yoshihiro
2007-04-01
An image by Eddy Current Testing(ECT) is a blurred image to original flaw shape. In order to reconstruct fine flaw image, a new image reconstruction method has been proposed. This method is based on an assumption that a very simple relationship between measured data and source were described by a convolution of response function and flaw shape. This assumption leads to a simple inverse analysis method with deconvolution.In this method, Point Spread Function (PSF) and Line Spread Function(LSF) play a key role in deconvolution processing. This study proposes a simple data processing to determine PSF and LSF from ECT data of machined hole and line flaw. In order to verify its validity, ECT data for SUS316 plate(200x200x10mm) with artificial machined hole and notch flaw had been acquired by differential coil type sensors(produced by ZETEC Inc). Those data were analyzed by the proposed method. The proposed method restored sharp discrete multiple hole image from interfered data by multiple holes. Also the estimated width of line flaw has been much improved compared with original experimental data. Although proposed inverse analysis strategy is simple and easy to implement, its validity to holes and line flaw have been shown by many results that much finer image than original image have been reconstructed.
de Sena, Rodrigo Caciano; Soares, Matheus; Pereira, Maria Luiza Oliveira; da Silva, Rogério Cruz Domingues; do Rosário, Francisca Ferreira; da Silva, Joao Francisco Cajaiba
2011-01-01
The development of a simple, rapid and low cost method based on video image analysis and aimed at the detection of low concentrations of precipitated barium sulfate is described. The proposed system is basically composed of a webcam with a CCD sensor and a conventional dichroic lamp. For this purpose, software for processing and analyzing the digital images based on the RGB (Red, Green and Blue) color system was developed. The proposed method had shown very good repeatability and linearity and also presented higher sensitivity than the standard turbidimetric method. The developed method is presented as a simple alternative for future applications in the study of precipitations of inorganic salts and also for detecting the crystallization of organic compounds. PMID:22346607
Visual conspicuity: a new simple standard, its reliability, validity and applicability.
Wertheim, A H
2010-03-01
A general standard for quantifying conspicuity is described. It derives from a simple and easy method to quantitatively measure the visual conspicuity of an object. The method stems from the theoretical view that the conspicuity of an object is not a property of that object, but describes the degree to which the object is perceptually embedded in, i.e. laterally masked by, its visual environment. First, three variations of a simple method to measure the strength of such lateral masking are described and empirical evidence for its reliability and its validity is presented, as are several tests of predictions concerning the effects of viewing distance and ambient light. It is then shown how this method yields a conspicuity standard, expressed as a number, which can be made part of a rule of law, and which can be used to test whether or not, and to what extent, the conspicuity of a particular object, e.g. a traffic sign, meets a predetermined criterion. An additional feature is that, when used under different ambient light conditions, the method may also yield an index of the amount of visual clutter in the environment. Taken together the evidence illustrates the methods' applicability in both the laboratory and in real-life situations. STATEMENT OF RELEVANCE: This paper concerns a proposal for a new method to measure visual conspicuity, yielding a numerical index that can be used in a rule of law. It is of importance to ergonomists and human factor specialists who are asked to measure the conspicuity of an object, such as a traffic or rail-road sign, or any other object. The new method is simple and circumvents the need to perform elaborate (search) experiments and thus has great relevance as a simple tool for applied research.
Local SIMPLE multi-atlas-based segmentation applied to lung lobe detection on chest CT
NASA Astrophysics Data System (ADS)
Agarwal, M.; Hendriks, E. A.; Stoel, B. C.; Bakker, M. E.; Reiber, J. H. C.; Staring, M.
2012-02-01
For multi atlas-based segmentation approaches, a segmentation fusion scheme which considers local performance measures may be more accurate than a method which uses a global performance measure. We improve upon an existing segmentation fusion method called SIMPLE and extend it to be localized and suitable for multi-labeled segmentations. We demonstrate the algorithm performance on 23 CT scans of COPD patients using a leave-one- out experiment. Our algorithm performs significantly better (p < 0.01) than majority voting, STAPLE, and SIMPLE, with a median overlap of the fissure of 0.45, 0.48, 0.55 and 0.6 for majority voting, STAPLE, SIMPLE, and the proposed algorithm, respectively.
Simple, Fast, and Sensitive Method for Quantification of Tellurite in Culture Media▿
Molina, Roberto C.; Burra, Radhika; Pérez-Donoso, José M.; Elías, Alex O.; Muñoz, Claudia; Montes, Rebecca A.; Chasteen, Thomas G.; Vásquez, Claudio C.
2010-01-01
A fast, simple, and reliable chemical method for tellurite quantification is described. The procedure is based on the NaBH4-mediated reduction of TeO32− followed by the spectrophotometric determination of elemental tellurium in solution. The method is highly reproducible, is stable at different pH values, and exhibits linearity over a broad range of tellurite concentrations. PMID:20525868
A SIMPLE HPLC METHOD FOR DETECTING CARBARYL AND 1-NAPHTHOL IN BIOLOGICAL TISSUES.
Carbamates are a class of pesticide used in both agricultural and residential applications. A simple HPLC method for detecting Carb and its metabolite 1-naphthol (Naph) in tissues was developed to try to correlate tissue levels of carbaryl (Carb) (a prototypical carbamate) with c...
Building Regression Models: The Importance of Graphics.
ERIC Educational Resources Information Center
Dunn, Richard
1989-01-01
Points out reasons for using graphical methods to teach simple and multiple regression analysis. Argues that a graphically oriented approach has considerable pedagogic advantages in the exposition of simple and multiple regression. Shows that graphical methods may play a central role in the process of building regression models. (Author/LS)
A Simple Estimation Method for Aggregate Government Outsourcing
ERIC Educational Resources Information Center
Minicucci, Stephen; Donahue, John D.
2004-01-01
The scholarly and popular debate on the delegation to the private sector of governmental tasks rests on an inadequate empirical foundation, as no systematic data are collected on direct versus indirect service delivery. We offer a simple method for approximating levels of service outsourcing, based on relatively straightforward combinations of and…
Lipid Extraction and Cholesterol Quantification: A Simple Protocol
ERIC Educational Resources Information Center
Barreto, M. Carmo
2005-01-01
Enzymatic methods are used to measure cholesterol levels but a simple and inexpensive method is described, which is particularly important when one has repeated lab sessions during the week. It can be carried out on the organic phase containing the lipids, without evaporating the solvent, yielding quick results.
SIMPLE MINI-METHOD TO EXTRACT BULK DNA DIRECTLY FROM SOIL FOR USE WITH PCR
A rapid, simple method is described, which yields amplifiable bacterial and fungal DNAs from soil. NA is extracted directly from soil and separated from the soil contaminants by electrophoresis in Nusieve GTG agarose. p to fifty 20 mg samples can be processed in one day.
Numerous extraction methods have been developed and used in the quantitation of both photopigments and mycosporine amino acids (MAAs) found in Symbiodinium sp. and zooanthellate metazoans. We have development of a simple, mild extraction procedure using methanol, which when coupl...
Mattfeldt, Torsten
2011-04-01
Computer-intensive methods may be defined as data analytical procedures involving a huge number of highly repetitive computations. We mention resampling methods with replacement (bootstrap methods), resampling methods without replacement (randomization tests) and simulation methods. The resampling methods are based on simple and robust principles and are largely free from distributional assumptions. Bootstrap methods may be used to compute confidence intervals for a scalar model parameter and for summary statistics from replicated planar point patterns, and for significance tests. For some simple models of planar point processes, point patterns can be simulated by elementary Monte Carlo methods. The simulation of models with more complex interaction properties usually requires more advanced computing methods. In this context, we mention simulation of Gibbs processes with Markov chain Monte Carlo methods using the Metropolis-Hastings algorithm. An alternative to simulations on the basis of a parametric model consists of stochastic reconstruction methods. The basic ideas behind the methods are briefly reviewed and illustrated by simple worked examples in order to encourage novices in the field to use computer-intensive methods. © 2010 The Authors Journal of Microscopy © 2010 Royal Microscopical Society.
Promoting protein crystallization using a plate with simple geometry.
Chen, Rui-Qing; Yin, Da-Chuan; Liu, Yong-Ming; Lu, Qin-Qin; He, Jin; Liu, Yue
2014-03-01
Increasing the probability of obtaining protein crystals in crystallization screening is always an important goal for protein crystallography. In this paper, a new method called the cross-diffusion microbatch (CDM) method is presented, which aims to efficiently promote protein crystallization and increase the chance of obtaining protein crystals. In this method, a very simple crystallization plate was designed in which all crystallization droplets are in one sealed space, so that a variety of volatile components from one droplet can diffuse into any other droplet via vapour diffusion. Crystallization screening and reproducibility tests indicate that this method could be a potentially powerful technique in practical protein crystallization screening. It can help to obtain crystals with higher probability and at a lower cost, while using a simple and easy procedure.
Montare, Alberto
2013-06-01
The three classical Donders' reaction time (RT) tasks (simple, choice, and discriminative RTs) were employed to compare reaction time scores from college students obtained by use of Montare's simplest chronoscope (meterstick) methodology to scores obtained by use of a digital-readout multi-choice reaction timer (machine). Five hypotheses were tested. Simple RT, choice RT, and discriminative RT were faster when obtained by meterstick than by machine. The meterstick method showed higher reliability than the machine method and was less variable. The meterstick method of the simplest chronoscope may help to alleviate the longstanding problems of low reliability and high variability of reaction time performances; while at the same time producing faster performance on Donders' simple, choice and discriminative RT tasks than the machine method.
Liao, Yi-Fang; Tsai, Meng-Li; Yen, Chen-Tung; Cheng, Chiung-Hsiang
2011-02-15
Heat-fusing is a common process for fabricating microwire tetrodes. However, it is time-consuming, and the high-temperature treatment can easily cause the insulation of the microwire to overheat leading to short circuits. We herein provide a simple, fast method to fabricate microwire tetrodes without the heat-fusion process. By increasing the twisting density, we were able to fabricate tetrodes with good rigidity and integrity. This kind of tetrode showed good recording quality, penetrated the brain surface easily, and remained intact after chronic implantation. This method requires only general laboratory tools and is relatively simple even for inexperienced workers. © 2010 Elsevier B.V. All rights reserved.
Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang
2013-09-01
We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.
Leakey, Tatiana I; Zielinski, Jerzy; Siegfried, Rachel N; Siegel, Eric R; Fan, Chun-Yang; Cooney, Craig A
2008-06-01
DNA methylation at cytosines is a widely studied epigenetic modification. Methylation is commonly detected using bisulfite modification of DNA followed by PCR and additional techniques such as restriction digestion or sequencing. These additional techniques are either laborious, require specialized equipment, or are not quantitative. Here we describe a simple algorithm that yields quantitative results from analysis of conventional four-dye-trace sequencing. We call this method Mquant and we compare it with the established laboratory method of combined bisulfite restriction assay (COBRA). This analysis of sequencing electropherograms provides a simple, easily applied method to quantify DNA methylation at specific CpG sites.
Sequeira, Patrícia Carvalho de; Fonseca, Leila de Souza; Silva, Marlei Gomes da; Saad, Maria Helena Féres
2005-11-01
Simple double repetitive element polymerase chain reaction (MaDRE-PCR) and Pvu II-IS1245 restriction fragment length polymorphism (RFLP) typing methods were used to type 41 Mycobacterium avium isolates obtained from 14 AIDS inpatients and 10 environment and animals specimens identified among 53 mycobacteria isolated from 237 food, chicken, and pig. All environmental and animals strains showed orphan patterns by both methods. By MaDRE-PCR four patients, with multiple isolates, showed different patterns, suggesting polyclonal infection that was confirmed by RFLP in two of them. This first evaluation of MaDRE-PCR on Brazilian M. avium strains demonstrated that the method seems to be useful as simple and less expensive typing method for screening genetic diversity in M. avium strains on selected epidemiological studies, although with limitation on analysis identical patterns except for one band.
Novel Approach for Solving the Equation of Motion of a Simple Harmonic Oscillator. Classroom Notes
ERIC Educational Resources Information Center
Gauthier, N.
2004-01-01
An elementary method, based on the use of complex variables, is proposed for solving the equation of motion of a simple harmonic oscillator. The method is first applied to the equation of motion for an undamped oscillator and it is then extended to the more important case of a damped oscillator. It is finally shown that the method can readily be…
Accounting For Gains And Orientations In Polarimetric SAR
NASA Technical Reports Server (NTRS)
Freeman, Anthony
1992-01-01
Calibration method accounts for characteristics of real radar equipment invalidating standard 2 X 2 complex-amplitude R (receiving) and T (transmitting) matrices. Overall gain in each combination of transmitting and receiving channels assumed different even when only one transmitter and one receiver used. One characterizes departure of polarimetric Synthetic Aperture Radar (SAR) system from simple 2 X 2 model in terms of single parameter used to transform measurements into format compatible with simple 2 X 2 model. Data processed by applicable one of several prior methods based on simple model.
[Artistic anatomy of the nose: proposals for a simplified project of rhinoplasty].
Polselli, R; Saban, Y
2007-01-01
The authors developed an original and simple method of evaluation of the aesthetic lines of the nose adapted to the harmony of the face. Initially based on their experience, the authors propose an evaluation of the nose in 2 stages and 5 sequencies based on the construction of single circuit lines according to various incidences. They checked thereafter the validity of this method on the operative project and on the appreciation of the results of the rhinoplasties. Controlled on several types of faces, the method suggested by the authors proved to be reliable, simple, reproducible. The authors proposed a method of evaluation of the aesthetic lines of the nose integrated to the harmony of the face. This method relies on the construction, in 5 stages, of single circuit lines not requiring any particular material. The artistic method of evaluation of the nose proposed by the authors is very simple. Rapid and immediately usable, it makes it possible to schedule a rhinoplasty in a few minutes. The evaluation of the aesthetic results of the rhinoplasties is also very simple and reproducible. It has moreover the merit to propose a model of teaching making it possible to the rhinoplastician to criticize his results and thus to progress in its technical training and its operational indications.
Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.
Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît
2017-01-01
To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV <1.0%. These results suggest that the simple method presented here is valid and reliable for computing CMJ force, velocity, power, and F-v profiles in athletes and could be used in practice under field conditions when body mass, push-off distance, and jump height are known.
Simple Common Plane contact detection algorithm for FE/FD methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vorobiev, O
2006-07-19
Common-plane (CP) algorithm is widely used in Discrete Element Method (DEM) to model contact forces between interacting particles or blocks. A new simple contact detection algorithm is proposed to model contacts in FE/FD methods which is similar to the CP algorithm. The CP is defined as a plane separating interacting faces of FE/FD mesh instead of blocks or particles in the original CP method. The method does not require iterations. It is very robust and easy to implement both in 2D and 3D case.
12 CFR 717.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2011 CFR
2011-01-01
... an Internet Web site, if the consumer agrees to the electronic delivery of information; (iv) Providing a toll-free telephone number that consumers may call to opt out; or (v) Allowing consumers to... single toll-free telephone number. (2) Opt-out methods that are not reasonable and simple. Reasonable and...
12 CFR 717.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2012 CFR
2012-01-01
... an Internet Web site, if the consumer agrees to the electronic delivery of information; (iv) Providing a toll-free telephone number that consumers may call to opt out; or (v) Allowing consumers to... single toll-free telephone number. (2) Opt-out methods that are not reasonable and simple. Reasonable and...
12 CFR 717.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2013 CFR
2013-01-01
... an Internet Web site, if the consumer agrees to the electronic delivery of information; (iv) Providing a toll-free telephone number that consumers may call to opt out; or (v) Allowing consumers to... single toll-free telephone number. (2) Opt-out methods that are not reasonable and simple. Reasonable and...
12 CFR 717.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2014 CFR
2014-01-01
... an Internet Web site, if the consumer agrees to the electronic delivery of information; (iv) Providing a toll-free telephone number that consumers may call to opt out; or (v) Allowing consumers to... single toll-free telephone number. (2) Opt-out methods that are not reasonable and simple. Reasonable and...
12 CFR 717.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2010 CFR
2010-01-01
... an Internet Web site, if the consumer agrees to the electronic delivery of information; (iv) Providing a toll-free telephone number that consumers may call to opt out; or (v) Allowing consumers to... single toll-free telephone number. (2) Opt-out methods that are not reasonable and simple. Reasonable and...
Knowledge acquisition for a simple expert controller
NASA Technical Reports Server (NTRS)
Bieker, B.
1987-01-01
A method is presented for process control which has the properties of being incremental, cyclic and top-down. It is described on the basis of the development of an expert controller for a simple, but nonlinear control route. A quality comparison between expert controller and process operator shows the ability of the method for knowledge acquisition.
17 CFR 162.7 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 17 Commodity and Securities Exchanges 1 2013-04-01 2013-04-01 false Reasonable and simple methods of opting out. 162.7 Section 162.7 Commodity and Securities Exchanges COMMODITY FUTURES TRADING... electronically mailed or processed through an Internet Web site; (4) Providing a toll-free telephone number; or...
17 CFR 162.7 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 17 Commodity and Securities Exchanges 1 2012-04-01 2012-04-01 false Reasonable and simple methods of opting out. 162.7 Section 162.7 Commodity and Securities Exchanges COMMODITY FUTURES TRADING... electronically mailed or processed through an Internet Web site; (4) Providing a toll-free telephone number; or...
17 CFR 162.7 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 17 Commodity and Securities Exchanges 2 2014-04-01 2014-04-01 false Reasonable and simple methods of opting out. 162.7 Section 162.7 Commodity and Securities Exchanges COMMODITY FUTURES TRADING... electronically mailed or processed through an Internet Web site; (4) Providing a toll-free telephone number; or...
A non-iterative twin image elimination method with two in-line digital holograms
NASA Astrophysics Data System (ADS)
Kim, Jongwu; Lee, Heejung; Jeon, Philjun; Kim, Dug Young
2018-02-01
We propose a simple non-iterative in-line holographic measurement method which can effectively eliminate a twin image in digital holographic 3D imaging. It is shown that a twin image can be effectively eliminated with only two measured holograms by using a simple numerical propagation algorithm and arithmetic calculations.
A simple and rapid radiochemical choline acetyltransferase (ChAT) assay screening test.
Shiba, Kazuhiro; Ogawa, Kazuma; Kinuya, Seigo; Yajima, Kazuyoshi; Mori, Hirofumi
2006-10-15
A simple radiochemical choline acetyltransferase (ChAT) assay screening test was developed by measuring for [(3)H]acetylcholine ([(3)H]ACh) formed from 0.2 mM [(3)H]acetyl-coenzyme A ([(3)H]acetyl-CoA) and 1 mM choline by 0.2 mg of rat brain homogenates containing ChAT into 96-well microplates. A simple and rapid procedure for isolating [(3)H]ACh from the incubation mixture into 96-well microplates was achieved by using a sodium tetraphenylboron (Kalibor) solution (in ethyl acetate, 0.75%, w/v) and a hydrophobic liquid scintillator mixture (1:5, v/v, 0.2 mL) as an extraction solvent. The benefits of this radiochemical method using 96-well microplates are as follows: (1) this method is reliable and reproducible; (2) many samples can be examined at the same time by this method; (3) this method is economical and effective in reducing radioactive waste. The development of a new simple radiochemical ChAT assay screening test is the first stage of development of radiolabeled ChAT mapping agent.
The Nonlinear Dynamic Response of an Elastic-Plastic Thin Plate under Impulsive Loading,
1987-06-11
Among those numerical methods, the finite element method is the most effective one. The method presented in this paper is an " influence function " numerical...computational time is much less than the finite element method. Its precision is higher also. II. Basic Assumption and the Influence Function of a Simple...calculation. Fig. 1 3 2. The Influence function of a Simple Supported Plate The motion differential equation of a thin plate can be written as DV’w+ _.eluq() (1
Two Methods for Teaching Simple Visual Discriminations to Learners with Severe Disabilities
ERIC Educational Resources Information Center
Graff, Richard B.; Green, Gina
2004-01-01
Simple discriminations are involved in many functional skills; additionally, they are components of conditional discriminations (identity and arbitrary matching-to-sample), which are involved in a wide array of other important performances. Many individuals with severe disabilities have difficulty acquiring simple discriminations with standard…
Li, Chunmei; Luo, Tingting; Zheng, Zhaozhu; Murphy, Amanda R.; Wang, Xiaoqin; Kaplan, David L.
2014-01-01
Curcumin, a natural phenolic compound derived from the plant Curcuma longa, was physically entrapped and stabilized in silk hydrogel films and its influence on human bone marrow-derived mesenchymal stem cells (hBMSCs) was assessed related to adipogenic differentiation. The presence of curcumin significantly reduced silk gelation time and changed the porous morphology of gel matrix, but did not change the formation of silk beta-sheet structure. Based on spectrofluorimetric analysis, curcumin likely interacted with hydrophobic residues in silk, interacting with the beta-sheet domains formed in the hydrogels. The antioxidant activity of silk film-associated curcumin remained functional over at least one month in both the dry and hydrated state. Negligible curcumin was released from silk hydrogel films over 48 hours incubation in aqueous solution. For hBMSCs cultured on silk films containing more than 0.25 mg/mL curcumin, cell proliferation was inhibited while adipogenesis was significantly promoted based on transcripts as well as oil red O staining. When hBMSCs were cultured in media containing free curcumin, both proliferation and adipogenesis of hBMSCs were inhibited when curcumin concentrations exceeded 5 μM, which is more than 1,000-times higher than the level of curcumin released from the films in aqueous solution. Thus, silk film-associated curcumin exhibited different effects on hBMSC proliferation and differentiation when compared to curcumin in solution. PMID:25132274
Synthesis and antiplasmodial activity of betulinic acid and ursolic acid analogues.
Innocente, Adrine M; Silva, Gloria N S; Cruz, Laura Nogueira; Moraes, Miriam S; Nakabashi, Myna; Sonnet, Pascal; Gosmann, Grace; Garcia, Célia R S; Gnoatto, Simone C B
2012-10-12
More than 40% of the World population is at risk of contracting malaria, which affects primarily poor populations in tropical and subtropical areas. Antimalarial pharmacotherapy has utilised plant-derived products such as quinine and artemisinin as well as their derivatives. However, worldwide use of these antimalarials has caused the spread of resistant parasites, resulting in increased malaria morbidity and mortality. Considering that the literature has demonstrated the antimalarial potential of triterpenes, specially betulinic acid (1) and ursolic acid (2), this study investigated the antimalarial activity against P. falciparum chloroquine-sensitive 3D7 strain of some new derivatives of 1 and 2 with modifications at C-3 and C-28. The antiplasmodial study employed flow cytometry and spectrofluorimetric analyses using YOYO-1, dihydroethidium and Fluo4/AM for staining. Among the six analogues obtained, compounds 1c and 2c showed excellent activity (IC₅₀ = 220 and 175 nM, respectively) while 1a and b demonstrated good activity (IC₅₀ = 4 and 5 μM, respectively). After cytotoxicity evaluation against HEK293T cells, 1a was not toxic, while 1c and 2c showed IC₅₀ of 4 μM and a selectivity index (SI) value of 18 and 23, respectively. Moreover, compound 2c, which presents the best antiplasmodial activity, is involved in the calcium-regulated pathway(s).
Ferreira, Rosa Cristina M; Raposo, Maria Manuela M; Costa, Susana P G
2018-06-01
A family of novel thienylbenzoxazol-5-yl-L-alanines, consisting of an alanine core bearing a benzoxazole at the side chain with a thiophene ring at position 2, substituted with different (hetero)aryl substituents, was synthesised to study the tuning of the photophysical and chemosensory properties of the resulting compounds. These novel heterocyclic alanines 3a-f and a series of structurally related bis-thienylbenzoxazolyl-alanines 3g-j were evaluated for the first time in the recognition of selected metal cations with environmental, medicinal and analytical interest such as Co 2+ , Cu 2+ , Zn 2+ and Ni 2+ , in acetonitrile solution, with the heterocycles at the side chain acting simultaneously as the coordinating and reporting units, via fluorescence changes. This behaviour can be explained by the involvement of the electron donor heteroatoms in the recognition event, through complexation of the metal cations. The spectrofluorimetric titrations showed that thienylbenzoxazolyl-alanines 3a-j and 4a,b were non-selective fluorimetric chemosensors for the above-mentioned cations, with the best results being obtained for the interaction of Cu 2+ with bis-alanine 3j and deprotected alanines 4a,b. The encouraging photophysical and metal ion sensing properties of these thienylbenzoxazolyl-alanines suggest that they can be used to obtain bioinspired fluorescent reporters for metal ion such as peptides/proteins with chemosensory/probing ability.
Duicu, Oana M; Privistirescu, Andreea; Wolf, Adrian; Petruş, Alexandra; Dănilă, Maria D; Raţiu, Corina D; Muntean, Danina M; Sturza, Adrian
2017-11-01
Diabetic cardiomyopathy has been systematically associated with compromised mitochondrial energetics and increased generation of reactive oxygen species (ROS) that underlie its progression to heart failure. Methylene blue is a redox drug with reported protective effects mainly on brain mitochondria. The purpose of the present study was to characterize the effects of acute administration of methylene blue on mitochondrial respiration, H 2 O 2 production, and calcium sensitivity in rat heart mitochondria isolated from healthy and 2 months (streptozotocin-induced) diabetic rats. Mitochondrial respiratory function was assessed by high-resolution respirometry. H 2 O 2 production and calcium retention capacity were measured spectrofluorimetrically. The addition of methylene blue (0.1 μmol·L -1 ) elicited an increase in oxygen consumption of mitochondria energized with complex I and II substrates in both normal and diseased mitochondria. Interestingly, methylene blue elicited a significant increase in H 2 O 2 release in the presence of complex I substrates (glutamate and malate), but had an opposite effect in mitochondria energized with complex II substrate (succinate). No changes in the calcium retention capacity of healthy or diabetic mitochondria were found in the presence of methylene blue. In conclusion, in cardiac mitochondria isolated from diabetic and nondiabetic rat hearts, methylene blue improved respiratory function and elicited a dichotomic, substrate-dependent effect on ROS production.
Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi
2016-02-01
Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62 mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.
deWit, D; Wootton, M; Allan, B; Steyn, L
1993-01-01
A simple method for the production of internal control DNA for two well-established Mycobacterium tuberculosis polymerase chain reaction assays is described. The internal controls were produced from Mycobacterium kansasii DNA with the same primers but at a lower annealing temperature than that used in the standard assays. In both assays, therefore, the internal control DNA has the same primer-binding sequences at the target DNA. One-microgram quantities of internal control DNA which was not contaminated with target DNA could easily be produced by this method. The inclusion of the internal control in the reaction mixture did not affect the efficiency of amplification of the target DNA. The method is simple and rapid and should be adaptable to most M. tuberculosis polymerase chain reaction assays. Images PMID:8370752
NASA Technical Reports Server (NTRS)
Edmonds, Larry D.
1987-01-01
The steady state current distribution in a three dimensional integrated circuit is presented. A device physics approach, based on a perturbation method rather than an equivalent lumped circuit approach, is used. The perturbation method allows the various currents to be expressed in terms of elementary solutions which are solutions to very simple boundary value problems. A Simple Steady State Theory is the subtitle because the most obvious limitation of the present version of the analysis is that all depletion region boundary surfaces are treated as equipotential surfaces. This may be an adequate approximation in some applications but it is an obvious weakness in the theory when applied to latched states. Examples that illustrate the use of these analytical methods are not given because they will be presented in detail in the future.
A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.
Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius
2017-01-01
The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.
Køppe, Simo; Dammeyer, Jesper
2014-09-01
The evolution of developmental psychology has been characterized by the use of different quantitative and qualitative methods and procedures. But how does the use of methods and procedures change over time? This study explores the change and development of statistical methods used in articles published in Child Development from 1930 to 2010. The methods used in every article in the first issue of every volume were categorized into four categories. Until 1980 relatively simple statistical methods were used. During the last 30 years there has been an explosive use of more advanced statistical methods employed. The absence of statistical methods or use of simple methods had been eliminated.
Using container weights to determine irrigation needs: A simple method
R. Kasten Dumroese; Mark E. Montville; Jeremiah R. Pinto
2015-01-01
Proper irrigation can reduce water use, water waste, and incidence of disease. Knowing when to irrigate plants in container nurseries can be determined by weighing containers. This simple method is quantifiable, which is a benefit when more than one worker is responsible for irrigation. Irrigation is necessary when the container weighs some target as a proportion of...
Testing a simple field method for assessing nitrate removal in riparian zones
Philippe Vidon; Michael G. Dosskey
2008-01-01
Being able to identify riparian sites that function better for nitrate removal from groundwater is critical to using efficiently the riparian zones for water quality management. For this purpose, managers need a method that is quick, inexpensive, and accurate enough to enable effective management decisions. This study assesses the precision and accuracy of a simple...
VET Program Completion Rates: An Evaluation of the Current Method. Occasional Paper
ERIC Educational Resources Information Center
National Centre for Vocational Education Research (NCVER), 2016
2016-01-01
This work asks one simple question: "how reliable is the method used by the National Centre for Vocational Education Research (NCVER) to estimate projected rates of VET program completion?" In other words, how well do early projections align with actual completion rates some years later? Completion rates are simple to calculate with a…
Determination of cellulose I crystallinity by FT-Raman spectroscopy
Umesh P. Agarwal; Richard S. Reiner; Sally A. Ralph
2009-01-01
Two new methods based on FT-Raman spectroscopy, one simple, based on band intensity ratio, and the other, using a partial least-squares (PLS) regression model, are proposed to determine cellulose I crystallinity. In the simple method, crystallinity in semicrystalline cellulose I samples was determined based on univariate regression that was first developed using the...
Global Study of the Simple Pendulum by the Homotopy Analysis Method
ERIC Educational Resources Information Center
Bel, A.; Reartes, W.; Torresi, A.
2012-01-01
Techniques are developed to find all periodic solutions in the simple pendulum by means of the homotopy analysis method (HAM). This involves the solution of the equations of motion in two different coordinate representations. Expressions are obtained for the cycles and periods of oscillations with a high degree of accuracy in the whole range of…
In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...
12 CFR 1022.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2013 CFR
2013-01-01
... (REGULATION V) Affiliate Marketing § 1022.25 Reasonable and simple methods of opting out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a..., 15 U.S.C. 6801 et seq., the affiliate sharing opt-out under the Act, and the affiliate marketing opt...
12 CFR 1022.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2014 CFR
2014-01-01
... (REGULATION V) Affiliate Marketing § 1022.25 Reasonable and simple methods of opting out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a..., 15 U.S.C. 6801 et seq., the affiliate sharing opt-out under the Act, and the affiliate marketing opt...
12 CFR 1022.25 - Reasonable and simple methods of opting out.
Code of Federal Regulations, 2012 CFR
2012-01-01
... (REGULATION V) Affiliate Marketing § 1022.25 Reasonable and simple methods of opting out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a..., 15 U.S.C. 6801 et seq., the affiliate sharing opt-out under the Act, and the affiliate marketing opt...
Cyanuric acide (CA) is widely used as a chlorine stabilizer in outdoor pools. No simple method exists for CA measurement in the urine of exposed swimmers. The high hydrophilicity of CA makes usage of solid phase sorbents to extract it from urine nearly impossible because of samp...
A Simple Spreadsheet Program for the Calculation of Lattice-Site Distributions
ERIC Educational Resources Information Center
McCaffrey, John G.
2009-01-01
A simple spreadsheet program is presented that can be used by undergraduate students to calculate the lattice-site distributions in solids. A major strength of the method is the natural way in which the correct number of ions or atoms are present, or absent, at specific lattice distances. The expanding-cube method utilized is straightforward to…
A Simple Method to Measure the Twist Elastic Constant of a Nematic Liquid Crystal
2015-01-01
for measuring the twist elastic constant (K22) of a nematic liquid crystal (LC). By adding some chiral dopant to an LC host, the LC directors rotate......of Optics and Photonics , University of Central Florida, Orlando, FL, USA (Received 14 June 2015; accepted 6 July 2015) We demonstrate a simple method
A Simple Demonstration of a General Rule for the Variation of Magnetic Field with Distance
ERIC Educational Resources Information Center
Kodama, K.
2009-01-01
We describe a simple experiment demonstrating the variation in magnitude of a magnetic field with distance. The method described requires only an ordinary magnetic compass and a permanent magnet. The proposed graphical analysis illustrates a unique method for deducing a general rule of magnetostatics. (Contains 1 table and 6 figures.)
Li, Jian; Milne, Robert W.; Nation, Roger L.; Turnidge, John D.; Coulthard, Kingsley; Valentine, Jason
2002-01-01
A simple and sensitive high-performance liquid chromatographic method is described for the determination of colistimethate sodium in plasma and urine. The accuracy and reproducibility was within 10.1 and 11.2% with rat plasma and urine, respectively. Several commonly coadministered antibacterial agents do not interfere with the assay. PMID:12234867
NASA Astrophysics Data System (ADS)
Deufel, Christopher L.; Furutani, Keith M.
2014-02-01
As dose optimization for high dose rate brachytherapy becomes more complex, it becomes increasingly important to have a means of verifying that optimization results are reasonable. A method is presented for using a simple optimization as quality assurance for the more complex optimization algorithms typically found in commercial brachytherapy treatment planning systems. Quality assurance tests may be performed during commissioning, at regular intervals, and/or on a patient specific basis. A simple optimization method is provided that optimizes conformal target coverage using an exact, variance-based, algebraic approach. Metrics such as dose volume histogram, conformality index, and total reference air kerma agree closely between simple and complex optimizations for breast, cervix, prostate, and planar applicators. The simple optimization is shown to be a sensitive measure for identifying failures in a commercial treatment planning system that are possibly due to operator error or weaknesses in planning system optimization algorithms. Results from the simple optimization are surprisingly similar to the results from a more complex, commercial optimization for several clinical applications. This suggests that there are only modest gains to be made from making brachytherapy optimization more complex. The improvements expected from sophisticated linear optimizations, such as PARETO methods, will largely be in making systems more user friendly and efficient, rather than in finding dramatically better source strength distributions.
A Simple Demonstration of Atomic and Molecular Orbitals Using Circular Magnets
ERIC Educational Resources Information Center
Chakraborty, Maharudra; Mukhopadhyay, Subrata; Das, Ranendu Sekhar
2014-01-01
A quite simple and inexpensive technique is described here to represent the approximate shapes of atomic orbitals and the molecular orbitals formed by them following the principles of the linear combination of atomic orbitals (LCAO) method. Molecular orbitals of a few simple molecules can also be pictorially represented. Instructors can employ the…
Multifactorial biogeochemical monitoring of linden alley in Moscow
NASA Astrophysics Data System (ADS)
Ermakov, Vadim; Khushvakhtova, Sabsbakhor; Tyutikov, Sergey; Danilova, Valentina; Roca, Núria; Bech, Jaume
2015-04-01
The ecological and biogeochemical assessment of the linden alley within the Kosygin Street was conducted by means of an integrated comparative study of soils, their chemical composition and morphological parameters of leaf linden. For this purpose 5 points were tested within the linden alley and 5 other points outside the highway. In soils, water extract of soil, leaf linden the content of Cu, Pb, Mn, Fe, Cd, Zn, As, Ni, Co Mo, Cr and Se were determined by AAS and spectrofluorimetric method [1]. Macrocomponents (Ca, Mg, K, Na, P, sulphates, chlorides), pH and total mineralization of water soil extract were measured by generally accepted methods. Thio-containing compounds in the leaves were determined by HPLC-NAM spectrofluorometry [2]. On level content of trace elements the soils of "contaminated" points different from background more high concentrations of lead, manganese, iron, selenium, strontium and low level of zinc. Leaf of linden from contaminated sites characterized by an increase of lead, copper, iron, zinc, arsenic, chromium, and a sharp decrease in the level of manganese and strontium. Analysis of the aqueous extracts of the soil showed a slight decrease in the pH value in the "control" points and lower content of calcium, magnesium, potassium, sodium and total mineralization of the water soil extract. The phytochelatins test in the leaves of linden was weakly effective and the degree of asymmetry of leaf lamina too. The most differences between the variants were marked by the degree of pathology leaves (chlorosis and necrosis) and the content of pigments (chlorophyll and carotene). The data obtained reflect the impact of the application of de-icing salts and automobile emissions. References 1. Ermakov V.V., Danilova V.N., Khyshvakhtova S.D. Application of HPLC-NAM spectrofluorimtry to determination of sulfur-containing compounds in the environmental objects// Science of the biosphere: Innovation. Moscow State University by M.V. Lomonosov, 2014. P. 10-12. 2. Ermakov V.V., Tyutikov S.F., Khushvakhtova S.D., Danilova V.N., Boev V.N., Barabanschikova R.N., Chudinova E.A. Peculiarities of quantitative determination of selenium in biological materials// Bulletin of the Tyumen State University Press, 2010, 3, 206-214. Supported by the Russian Foundation for Basic Research, grant number 15-05-00279a
Single Spore Isolation as a Simple and Efficient Technique to obtain fungal pure culture
NASA Astrophysics Data System (ADS)
Noman, E.; Al-Gheethi, AA; Rahman, N. K.; Talip, B.; Mohamed, R.; H, N.; Kadir, O. A.
2018-04-01
The successful identification of fungi by phenotypic methods or molecular technique depends mainly on the using an advanced technique for purifying the isolates. The most efficient is the single spore technique due to the simple requirements and the efficiency in preventing the contamination by yeast, mites or bacteria. The method described in the present work is depends on the using of a light microscope to transfer one spore into a new culture medium. The present work describes a simple and efficient procedure for single spore isolation to purify of fungi recovered from the clinical wastes.
NASA Astrophysics Data System (ADS)
Vespe, Francesco; Benedetto, Catia
2013-04-01
The huge amount of GPS Radio Occultation (RO) observations currently available thanks to space mission like COSMIC, CHAMP, GRACE, TERRASAR-X etc., have greatly encouraged the research of new algorithms suitable to extract humidity, temperature and pressure profiles of the atmosphere in a more and more precise way. For what concern the humidity profiles in these last years two different approaches have been widely proved and applied: the "Simple" and the 1DVAR methods. The Simple methods essentially determine dry refractivity profiles from temperature analysis profiles and hydrostatic equation. Then the dry refractivity is subtracted from RO refractivity to achieve the wet component. Finally from the wet refractivity is achieved humidity. The 1DVAR approach combines RO observations with profiles given by the background models with both the terms weighted with the inverse of covariance matrix. The advantage of "Simple" methods is that they are not affected by bias due to the background models. We have proposed in the past the BPV approach to retrieve humidity. Our approach can be classified among the "Simple" methods. The BPV approach works with dry atmospheric CIRA-Q models which depend on latitude, DoY and height. The dry CIRA-Q refractivity profile is selected estimating the involved parameters in a non linear least square fashion achieved by fitting RO observed bending angles through the stratosphere. The BPV as well as all the other "Simple" methods, has as drawback the unphysical occurrence of negative "humidity". Thus we propose to apply a modulated weighting of the fit residuals just to minimize the effects of this inconvenient. After a proper tuning of the approach, we plan to present the results of the validation.
Arthroscopic Medial Meniscus Posterior Root Fixation Using a Modified Mason-Allen Stitch.
Chung, Kyu Sung; Ha, Jeong Ku; Ra, Ho Jong; Kim, Jin Goo
2016-02-01
A complete radial tear of the meniscus posterior root, which can effectively cause a state of total meniscectomy via loss of hoop tension, requires that the torn root be repaired. Several methods have been used to repair medial meniscus posterior root tears, most of which are based on a simple stitch technique that is known to have stitch-holding strength. We applied a modified version of the Mason-Allen stitch technique, which is recognized as a method for rotator cuff repair surgery because its locking effect overcomes the potential weakness of simple stitches. This article introduces the medial meniscus posterior root tears repair procedure based on a modified Mason-Allen stitch technique in which 2 strands (i.e., 1 simple horizontal and 1 simple vertical stitch) are used.
Simple Common Plane contact algorithm for explicit FE/FD methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vorobiev, O
2006-12-18
Common-plane (CP) algorithm is widely used in Discrete Element Method (DEM) to model contact forces between interacting particles or blocks. A new simple contact algorithm is proposed to model contacts in FE/FD methods which is similar to the CP algorithm. The CP is defined as a plane separating interacting faces of FE/FD mesh instead of blocks or particles used in the original CP method. The new method does not require iterations even for very stiff contacts. It is very robust and easy to implement both in 2D and 3D parallel codes.
Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru
2013-11-01
The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (p<0.001), but the distance of that was so small (mean, 0.47 mm) that it did not cause any problem clinically. Although further improvement might be needed, such as screw specification, the closed reduction and internal fixation method has many advantages: short operative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.
A simple method for multiday imaging of slice cultures.
Seidl, Armin H; Rubel, Edwin W
2010-01-01
The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.
A simple and inexpensive method for muddy shore profiling
NASA Astrophysics Data System (ADS)
Chowdhury, Sayedur Rahman; Hossain, M. Shahadat; Sharifuzzaman, S. M.
2014-11-01
There are several well-established methods for obtaining beach profiles, and more accurate and precise high-tech methods are emerging. Traditional low-cost methods requiring minimal user skill or training are still popular among professionals, scientists, and coastal zone management practitioners. Simple methods are being developed with a primary focus on sand and gravel beaches. This paper describes a simple, low-cost, manual field method for measuring profiles of beaches, which is particularly suitable for muddy shores. The equipment is a type of flexible U-tube manometer that uses liquid columns in vertical tubes to measure differences in elevation; the supporting frame is constructed from wooden poles with base disks, which hold measuring scales and a PVC tube. The structure was trialed on a mudflat characterized by a 20-40-cm-thick surface layer of silt and clay, located at the Kutubdia Island, Bangladesh. The study results are discussed with notes on the method's applicability, advantages and limitations, and several optional modifications for different scenarios for routine profiling of muddy shores. The equipment can be used by one person or two people, and the accuracy of the method is comparable to those in other methods. The equipment can also be used on sandy or gravel beaches.
NASA Technical Reports Server (NTRS)
Thanedar, B. D.
1972-01-01
A simple repetitive calculation was used to investigate what happens to the field in terms of the signal paths of disturbances originating from the energy source. The computation allowed the field to be reconstructed as a function of space and time on a statistical basis. The suggested Monte Carlo method is in response to the need for a numerical method to supplement analytical methods of solution which are only valid when the boundaries have simple shapes, rather than for a medium that is bounded. For the analysis, a suitable model was created from which was developed an algorithm for the estimation of acoustic pressure variations in the region under investigation. The validity of the technique was demonstrated by analysis of simple physical models with the aid of a digital computer. The Monte Carlo method is applicable to a medium which is homogeneous and is enclosed by either rectangular or curved boundaries.
Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian
2018-03-01
We investigate a simple and accurate method for quantitatively analyzing dissolved inorganic carbon in environmental water by reaction headspace gas chromatography. The neutralization reaction between the inorganic carbon species (i.e. bicarbonate ions and carbonate ions) in environmental water and hydrochloric acid is carried out in a sealed headspace vial, and the carbon dioxide formed from the neutralization reaction, the self-decomposition of carbonic acid, and dissolved carbon dioxide in environmental water is then analyzed by headspace gas chromatography. The data show that the headspace gas chromatography method has good precision (relative standard deviation ≤ 1.63%) and accuracy (relative differences ≤ 5.81% compared with the coulometric titration technique). The headspace gas chromatography method is simple, reliable, and can be well applied in the dissolved inorganic carbon detection in environmental water. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A simple performance calculation method for LH2/LOX engines with different power cycles
NASA Technical Reports Server (NTRS)
Schmucker, R. H.
1973-01-01
A simple method for the calculation of the specific impulse of an engine with a gas generator cycle is presented. The solution is obtained by a power balance between turbine and pump. Approximate equations for the performance of the combustion products of LH2/LOX are derived. Performance results are compared with solutions of different engine types.
A simple technique for measurement of pressure in the tympanitic rumen of cattle.
Turner, C B; Whyte, T D
1978-05-13
The construction and method of use of a simple device for the non-invasive measurement of intra-rumenal pressure is outlined. Results obtained from calves suffering from increased intra-rumenal pressure (bloat) are shown. The method is capable of quantifying pressures involved in bloat and could be used to augment the visual assessment of bloat scoring.
Two Magnets and a Ball Bearing: A Simple Demonstration of the Methods of Images.
ERIC Educational Resources Information Center
Poon, W. C. K.
2003-01-01
Investigates the behavior of a bar magnet with a steel ball bearing on one pole as it approaches another bar magnet. Maps the problem onto electrostatics and explains observations based on the behavior of point charges near an isolated, uncharged sphere. Offers a simple demonstration of the method of images in electrostatics. (Author/NB)
A Simple Method for Nucleon-Nucleon Cross Sections in a Nucleus
NASA Technical Reports Server (NTRS)
Tripathi, R. K.; Cucinotta, Francis A.; Wilson, John W.
1999-01-01
A simple reliable formalism is presented for obtaining nucleon-nucleon cross sections within a nucleus in nuclear collisions for a given projectile and target nucleus combination at a given energy for use in transport, Monte Carlo, and other calculations. The method relies on extraction of these values from experiments and has been tested and found to give excellent results.
NASA Astrophysics Data System (ADS)
Shikhaliev, I. I.; Gainov, V. V.; Dorozhkin, A. N.; Nanii, O. E.; Konyshev, V. A.; Treshchikov, V. N.
2017-11-01
This paper describes techniques for measuring the SRS coefficient in a wide spectral range, including the region of small Stokes shifts. A simple, approximate method is proposed for evaluating the SRS coefficient near a gain peak. Spectral dependences of the SRS coefficient are presented for various telecom fibres.
ERIC Educational Resources Information Center
Valverde, Juan; This, Herve; Vignolle, Marc
2007-01-01
A simple method for the quantitative determination of photosynthetic pigments extracted from green beans using thin-layer chromatography is proposed. Various extraction methods are compared, and it is shown how a simple flatbed scanner and free software for image processing can give a quantitative determination of pigments. (Contains 5 figures.)
A Simple Geometric Method of Estimating the Error in Using Vieta's Product for [pi
ERIC Educational Resources Information Center
Osler, T. J.
2007-01-01
Vieta's famous product using factors that are nested radicals is the oldest infinite product as well as the first non-iterative method for finding [pi]. In this paper a simple geometric construction intimately related to this product is described. The construction provides the same approximations to [pi] as are given by partial products from…
ERIC Educational Resources Information Center
Martin, Michael J.
2004-01-01
With new and inexpensive computer-based methods, measuring the speed of light and the Earth's radius--historically difficult endeavors--can be simple enough to be tackled by high school and college students working in labs that have limited budgets. In this article, the author describes two methods of estimating the Earth's radius using two…
ERIC Educational Resources Information Center
Beare, R. A.
2008-01-01
Professional astronomers use specialized software not normally available to students to determine the rotation periods of asteroids from fragmented light curve data. This paper describes a simple yet accurate method based on Microsoft Excel[R] that enables students to find periods in asteroid light curve and other discontinuous time series data of…
Simple methods to reduce major allergen Ara h 1 and Ana o 1/2 in peanut and cashew extracts
USDA-ARS?s Scientific Manuscript database
Whole peanut extracts are usually used in immunotherapy but may have side effects. Reducing major peanut allergen(s) in the extracts may reduce the side effects. Three simple methods were evaluated to reduce major allergen Ara h 1 from a peanut extract: (1) treatment with p-aminobenzamidine (pABA); ...
NASA Technical Reports Server (NTRS)
Love, Eugene S
1957-01-01
A reexamination has been made of the use of simple concepts for predicting the shape and location of detached shock waves. The results show that simple concepts and modifications of existing methods can yield good predictions for many nose shapes and for a wide range of Mach numbers.
Ezzati Nazhad Dolatabadi, Jafar; Hamishehkar, Hamed; de la Guardia, Miguel; Valizadeh, Hadi
2014-01-01
Introduction: Alendronate sodium enhances bone formation and increases osteoblast proliferation and maturation and leads to the inhibition of osteoblast apoptosis. Therefore, a rapid and simple spectrofluorometric method has been developed and validated for the quantitative determination of it. Methods: The procedure is based on the reaction of primary amino group of alendronate with o-phthalaldehyde (OPA) in sodium hydroxide solution. Results: The calibration graph was linear over the concentration range of 0.0-2.4 μM and limit of detection and limit of quantification of the method was 8.89 and 29 nanomolar, respectively. The enthalpy and entropy of the reaction between alendronate sodium and OPA showed that the reaction is endothermic and entropy favored (ΔH = 154.08 kJ/mol; ΔS = 567.36 J/mol K) which indicates that OPA interaction with alendronate is increased at elevated temperature. Conclusion: This simple method can be used as a practical technique for the analysis of alendronate in various samples. PMID:24790897
Ahmad Khan, Hayat; Bashir Shah, Adil; Kamal, Younis
2016-11-01
Patellar dislocation is an emergency. Vertical patellar dislocation is rare, often seen in adolescents and mostly due to sports injuries or high-velocity trauma. Few cases have been reported in the literature. Closed or open reduction under general anesthesia is often needed. We report a case of vertical locked patellar dislocation in a 26-year-old male, which was reduced by a simple closed method under spinal anaesthesia. A literature review regarding the various methods of treatment is also discussed. A 26-year-old male experienced a trivial accident while descending stairs, sustaining patellar dislocation. The closed method of reduction was attempted, using a simple technique. Reduction was confirmed and postoperative rehabilitation was started. Follow-up was uneventful. Vertical patellar dislocations are encountered rarely in the emergency department. Adolescents are not the only victims, and high-velocity trauma is not the essential cause. Unnecessary manipulation should be avoided. The closed reduction method is simple, but the surgeon should be prepared for open reduction.
Single block three-dimensional volume grids about complex aerodynamic vehicles
NASA Technical Reports Server (NTRS)
Alter, Stephen J.; Weilmuenster, K. James
1993-01-01
This paper presents an alternate approach for the generation of volumetric grids for supersonic and hypersonic flows about complex configurations. The method uses parametric two dimensional block face grid definition within the framework of GRIDGEN2D. The incorporation of face decomposition reduces complex surfaces to simple shapes. These simple shapes are combined to obtain the final face definition. The advantages of this method include the reduction of overall grid generation time through the use of vectorized computer code, the elimination of the need to generate matching block faces, and the implementation of simplified boundary conditions. A simple axisymmetric grid is used to illustrate this method. In addition, volume grids for two complex configurations, the Langley Lifting Body (HL-20) and the Space Shuttle Orbiter, are shown.
Wada, Takahito; Shimbo, Hiroko; Osaka, Hitoshi
2012-08-01
Cerebral creatine deficiency syndromes (CCDS) are caused by genetic defects in L-arginine:glycine amidinotransferase, guanidinoacetate methyltransferase or creatine transporter 1. CCDS are characterized by abnormal concentrations of urinary creatine (CR), guanidinoacetic acid (GA), or creatinine (CN). In this study, we describe a simple HPLC method to determine the concentrations of CR, GA, and CN using a weak-acid ion chromatography column with a UV detector without any derivatization. CR, GA, and CN were separated clearly with the retention times (mean ± SD, n = 3) of 5.54 ± 0.0035 min for CR, 6.41 ± 0.0079 min for GA, and 13.53 ± 0.046 min for CN. This new method should provide a simple screening test for the diagnosis of CCDS.
Inverse kinematic solution for near-simple robots and its application to robot calibration
NASA Technical Reports Server (NTRS)
Hayati, Samad A.; Roston, Gerald P.
1986-01-01
This paper provides an inverse kinematic solution for a class of robot manipulators called near-simple manipulators. The kinematics of these manipulators differ from those of simple-robots by small parameter variations. Although most robots are by design simple, in practice, due to manufacturing tolerances, every robot is near-simple. The method in this paper gives an approximate inverse kinematics solution for real time applications based on the nominal solution for these robots. The validity of the results are tested both by a simulation study and by applying the algorithm to a PUMA robot.
NASA Astrophysics Data System (ADS)
Mustak, S.
2013-09-01
The correction of atmospheric effects is very essential because visible bands of shorter wavelength are highly affected by atmospheric scattering especially of Rayleigh scattering. The objectives of the paper is to find out the haze values present in the all spectral bands and to correct the haze values for urban analysis. In this paper, Improved Dark Object Subtraction method of P. Chavez (1988) is applied for the correction of atmospheric haze in the Resoucesat-1 LISS-4 multispectral satellite image. Dark object Subtraction is a very simple image-based method of atmospheric haze which assumes that there are at least a few pixels within an image which should be black (% reflectance) and such black reflectance termed as dark object which are clear water body and shadows whose DN values zero (0) or Close to zero in the image. Simple Dark Object Subtraction method is a first order atmospheric correction but Improved Dark Object Subtraction method which tends to correct the Haze in terms of atmospheric scattering and path radiance based on the power law of relative scattering effect of atmosphere. The haze values extracted using Simple Dark Object Subtraction method for Green band (Band2), Red band (Band3) and NIR band (band4) are 40, 34 and 18 but the haze values extracted using Improved Dark Object Subtraction method are 40, 18.02 and 11.80 for aforesaid bands. Here it is concluded that the haze values extracted by Improved Dark Object Subtraction method provides more realistic results than Simple Dark Object Subtraction method.
Path-Following Solutions Of Nonlinear Equations
NASA Technical Reports Server (NTRS)
Barger, Raymond L.; Walters, Robert W.
1989-01-01
Report describes some path-following techniques for solution of nonlinear equations and compares with other methods. Use of multipurpose techniques applicable at more than one stage of path-following computation results in system relatively simple to understand, program, and use. Comparison of techniques with method of parametric differentiation (MPD) reveals definite advantages for path-following methods. Emphasis in investigation on multiuse techniques being applied at more than one stage of path-following computation. Incorporation of multipurpose techniques results in concise computer code relatively simple to use.
Influence of parameter changes to stability behavior of rotors
NASA Technical Reports Server (NTRS)
Fritzen, C. P.; Nordmann, R.
1982-01-01
The occurrence of unstable vibrations in rotating machinery requires corrective measures for improvement of the stability behavior. A simple approximate method is represented to find out the influence of parameter changes to the stability behavior. The method is based on an expansion of the eigenvalues in terms of system parameters. Influence coefficients show the effect of structural modifications. The method first of all was applied to simple nonconservative rotor models. It was approved for an unsymmetric rotor of a test rig.
Methods for estimating 2D cloud size distributions from 1D observations
Romps, David M.; Vogelmann, Andrew M.
2017-08-04
The two-dimensional (2D) size distribution of clouds in the horizontal plane plays a central role in the calculation of cloud cover, cloud radiative forcing, convective entrainment rates, and the likelihood of precipitation. Here, a simple method is proposed for calculating the area-weighted mean cloud size and for approximating the 2D size distribution from the 1D cloud chord lengths measured by aircraft and vertically pointing lidar and radar. This simple method (which is exact for square clouds) compares favorably against the inverse Abel transform (which is exact for circular clouds) in the context of theoretical size distributions. Both methods also performmore » well when used to predict the size distribution of real clouds from a Landsat scene. When applied to a large number of Landsat scenes, the simple method is able to accurately estimate the mean cloud size. Finally, as a demonstration, the methods are applied to aircraft measurements of shallow cumuli during the RACORO campaign, which then allow for an estimate of the true area-weighted mean cloud size.« less
Methods for estimating 2D cloud size distributions from 1D observations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romps, David M.; Vogelmann, Andrew M.
The two-dimensional (2D) size distribution of clouds in the horizontal plane plays a central role in the calculation of cloud cover, cloud radiative forcing, convective entrainment rates, and the likelihood of precipitation. Here, a simple method is proposed for calculating the area-weighted mean cloud size and for approximating the 2D size distribution from the 1D cloud chord lengths measured by aircraft and vertically pointing lidar and radar. This simple method (which is exact for square clouds) compares favorably against the inverse Abel transform (which is exact for circular clouds) in the context of theoretical size distributions. Both methods also performmore » well when used to predict the size distribution of real clouds from a Landsat scene. When applied to a large number of Landsat scenes, the simple method is able to accurately estimate the mean cloud size. Finally, as a demonstration, the methods are applied to aircraft measurements of shallow cumuli during the RACORO campaign, which then allow for an estimate of the true area-weighted mean cloud size.« less
Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.
Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel
2016-11-01
A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.
Simple and rapid quantification of brominated vegetable oil in commercial soft drinks by LC–MS
Chitranshi, Priyanka; da Costa, Gonçalo Gamboa
2016-01-01
We report here a simple and rapid method for the quantification of brominated vegetable oil (BVO) in soft drinks based upon liquid chromatography–electrospray ionization mass spectrometry. Unlike previously reported methods, this novel method does not require hydrolysis, extraction or derivatization steps, but rather a simple “dilute and shoot” sample preparation. The quantification is conducted by mass spectrometry in selected ion recording mode and a single point standard addition procedure. The method was validated in the range of 5–25 μg/mL BVO, encompassing the legal limit of 15 μg/mL established by the US FDA for fruit-flavored beverages in the US market. The method was characterized by excellent intra- and inter-assay accuracy (97.3–103.4%) and very low imprecision [0.5–3.6% (RSD)]. The direct nature of the quantification, simplicity, and excellent statistical performance of this methodology constitute clear advantages in relation to previously published methods for the analysis of BVO in soft drinks. PMID:27451219
ERIC Educational Resources Information Center
Physics Education, 1982
1982-01-01
Describes: (1) an apparatus which provides a simple method for measuring Stefan's constant; (2) a simple phase shifting circuit; (3) a radioactive decay computer program (for ZX81); and (4) phase difference between transformer voltages. (Author/JN)
May, S L; May, W A; Bourdoux, P P; Pino, S; Sullivan, K M; Maberly, G F
1997-05-01
The measurement of urinary iodine in population-based surveys provides a biological indicator of the severity of iodine-deficiency disorders. We describe the steps performed to validate a simple, inexpensive, manual urinary iodine acid digestion method, and compare the results using this method with those of other urinary iodine methods. Initially, basic performance characteristics were evaluated: the average recovery of added iodine was 100.4 +/- 8.7% (mean +/- SD), within-assay precision (CV) over the assay range 0-0.95 mumol/L (0-12 micrograms/dL) was < 6%, between-assay precision over the same range was < 12%, and assay sensitivity was 0.05 mumol/L (0.6 microgram/dL). There were no apparent effects on the method by thiocyanate, a known interfering substance. In a comparison with five other methods performed in four different laboratories, samples were collected to test the method performance over a wide range of urinary iodine values (0.04-3.7 mumol/L, or 0.5-47 micrograms/dL). There was a high correlation between all methods and the interpretation of the results was consistent. We conclude that the simple, manual acid digestion method is suitable for urinary iodine analysis.
A Coupling Strategy of FEM and BEM for the Solution of a 3D Industrial Crack Problem
NASA Astrophysics Data System (ADS)
Kouitat Njiwa, Richard; Taha Niane, Ngadia; Frey, Jeremy; Schwartz, Martin; Bristiel, Philippe
2015-03-01
Analyzing crack stability in an industrial context is challenging due to the geometry of the structure. The finite element method is effective for defect-free problems. The boundary element method is effective for problems in simple geometries with singularities. We present a strategy that takes advantage of both approaches. Within the iterative solution procedure, the FEM solves a defect-free problem over the structure while the BEM solves the crack problem over a fictitious domain with simple geometry. The effectiveness of the approach is demonstrated on some simple examples which allow comparison with literature results and on an industrial problem.
Cao, Zhaoliang; Mu, Quanquan; Hu, Lifa; Lu, Xinghai; Xuan, Li
2009-09-28
A simple method for evaluating the wavefront compensation error of diffractive liquid-crystal wavefront correctors (DLCWFCs) for atmospheric turbulence correction is reported. A simple formula which describes the relationship between pixel number, DLCWFC aperture, quantization level, and atmospheric coherence length was derived based on the calculated atmospheric turbulence wavefronts using Kolmogorov atmospheric turbulence theory. It was found that the pixel number across the DLCWFC aperture is a linear function of the telescope aperture and the quantization level, and it is an exponential function of the atmosphere coherence length. These results are useful for people using DLCWFCs in atmospheric turbulence correction for large-aperture telescopes.
Robustifying blind image deblurring methods by simple filters
NASA Astrophysics Data System (ADS)
Liu, Yan; Zeng, Xiangrong; Huangpeng, Qizi; Fan, Jun; Zhou, Jinglun; Feng, Jing
2016-07-01
The state-of-the-art blind image deblurring (BID) methods are sensitive to noise, and most of them can deal with only small levels of Gaussian noise. In this paper, we use simple filters to present a robust BID framework which is able to robustify exiting BID methods to high-level Gaussian noise or/and Non-Gaussian noise. Experiments on images in presence of Gaussian noise, impulse noise (salt-and-pepper noise and random-valued noise) and mixed Gaussian-impulse noise, and a real-world blurry and noisy image show that the proposed method can faster estimate sharper kernels and better images, than that obtained by other methods.
Measurement method for the refractive index of thick solid and liquid layers.
Santić, Branko; Gracin, Davor; Juraić, Krunoslav
2009-08-01
A simple method is proposed for the refractive index measurement of thick solid and liquid layers. In contrast to interferometric methods, no mirrors are used, and the experimental setup is undemanding and simple. The method is based on the variation of transmission caused by optical interference within the layer as a function of incidence angle. A new equation is derived for the positions of the interference extrema versus incidence angle. Scattering at the surfaces and within the sample, as well as weak absorption, do not play important roles. The method is illustrated by the refractive index measurements of sapphire, window glass, and water.
Simple Excitation of Standing Waves in Rubber Bands and Membranes
NASA Astrophysics Data System (ADS)
Cortel, Adolf
2004-04-01
Many methods to excite standing waves in strings, plates, membranes, rods, tubes, and soap bubbles have been described. Usually a loudspeaker or a vibrating reed is driven by the amplified output of an audio oscillator. A novel and simple method consists of using a tuning fork or a singing rod to excite transversal standing waves in stretched rubber membranes sprinkled with fine sand.
Graphitic carbon stabilized silver nanoparticles synthesized by a simple chemical precursor method
NASA Astrophysics Data System (ADS)
Soni, Bhasker; Biswas, Somnath
2018-04-01
Monodispersed graphitic carbon stabilized silver nanoparticles (AgNPs) were synthesized following a simple chemical precursor method. The precursor was obtained by a controlled reduction of Ag+ in aqueous solution of poly-vinyl alcohol (PVA) and sucrose. The process allows precise control over the morphology of the AgNPs along with in situ formation of a surface stabilization layer of graphitic carbon.
Prophylactic Z-plasty - correcting helical rim deformity from wedge excision.
Kim, Peter
2010-09-01
Wedge excision is a popular and well documented surgical method for treating a wide range of skin lesions and cancers of the ear in the general practice setting. In the majority of cases, this is a simple and cosmetically pleasing treatment. However, it may create helical rim deformity. This article describes a simple method of preventing such deformity using prophylactic Z-plasty.
NASA Astrophysics Data System (ADS)
Sabirov, K.; Rakhmanov, S.; Matrasulov, D.; Susanto, H.
2018-04-01
We consider the stationary sine-Gordon equation on metric graphs with simple topologies. Exact analytical solutions are obtained for different vertex boundary conditions. It is shown that the method can be extended for tree and other simple graph topologies. Applications of the obtained results to branched planar Josephson junctions and Josephson junctions with tricrystal boundaries are discussed.
A simple and novel grading method for retraction and overshoot in Duane retraction syndrome.
Kekunnaya, Ramesh; Moharana, Ruby; Tibrewal, Shailja; Chhablani, Preeti-Patil; Sachdeva, Virender
2016-11-01
Strabismus in Duane retraction syndrome is frequently associated with significant globe retraction and overshoots. However, there is no method to objectively grade retraction and overshoot. Our purpose is to describe a novel objective grading method. This novel and simple grading method has excellent agreement. It will help standardise measurements and guide the clinician in taking the decision for surgery and predicting its outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Etard, Christelle; Joshi, Swarnima; Stegmaier, Johannes; Mikut, Ralf; Strähle, Uwe
2017-12-01
A bottleneck in CRISPR/Cas9 genome editing is variable efficiencies of in silico-designed gRNAs. We evaluated the sensitivity of the TIDE method (Tracking of Indels by DEcomposition) introduced by Brinkman et al. in 2014 for assessing the cutting efficiencies of gRNAs in zebrafish. We show that this simple method, which involves bulk polymerase chain reaction amplification and Sanger sequencing, is highly effective in tracking well-performing gRNAs in pools of genomic DNA derived from injected embryos. The method is equally effective for tracing INDELs in heterozygotes.
A comparison of methods for teaching receptive language to toddlers with autism.
Vedora, Joseph; Grandelski, Katrina
2015-01-01
The use of a simple-conditional discrimination training procedure, in which stimuli are initially taught in isolation with no other comparison stimuli, is common in early intensive behavioral intervention programs. Researchers have suggested that this procedure may encourage the development of faulty stimulus control during training. The current study replicated previous work that compared the simple-conditional and the conditional-only methods to teach receptive labeling of pictures to young children with autism spectrum disorder. Both methods were effective, but the conditional-only method required fewer sessions to mastery. © Society for the Experimental Analysis of Behavior.
Pseudo-simple heteroclinic cycles in R4
NASA Astrophysics Data System (ADS)
Chossat, Pascal; Lohse, Alexander; Podvigina, Olga
2018-06-01
We study pseudo-simple heteroclinic cycles for a Γ-equivariant system in R4 with finite Γ ⊂ O(4) , and their nearby dynamics. In particular, in a first step towards a full classification - analogous to that which exists already for the class of simple cycles - we identify all finite subgroups of O(4) admitting pseudo-simple cycles. To this end we introduce a constructive method to build equivariant dynamical systems possessing a robust heteroclinic cycle. Extending a previous study we also investigate the existence of periodic orbits close to a pseudo-simple cycle, which depends on the symmetry groups of equilibria in the cycle. Moreover, we identify subgroups Γ ⊂ O(4) , Γ ⊄ SO(4) , admitting fragmentarily asymptotically stable pseudo-simple heteroclinic cycles. (It has been previously shown that for Γ ⊂ SO(4) pseudo-simple cycles generically are completely unstable.) Finally, we study a generalized heteroclinic cycle, which involves a pseudo-simple cycle as a subset.
Characterization of Louisiana asphalt mixtures using simple performance tests and MEPDG.
DOT National Transportation Integrated Search
2014-04-01
The National Cooperative Highway Research Program (NCHRP) Project 9-19, Superpave Support and Performance : Models Management, recommended three Simple Performance Tests (SPTs) to complement the Superpave volumetric : mixture design method. These are...
NASA Astrophysics Data System (ADS)
Youn, Younghan; Koo, Jeong-Seo
The complete evaluation of the side vehicle structure and the occupant protection is only possible by means of the full scale side impact crash test. But, auto part manufacturers such as door trim makers can not conduct the test especially when the vehicle is under the developing process. The main objective of this study is to obtain the design guidelines by a simple component level impact test. The relationship between the target absorption energy and impactor speed were examined using the energy absorbed by the door trim. Since each different vehicle type required different energy levels on the door trim. A simple impact test method was developed to estimate abdominal injury by measuring reaction force of the impactor. The reaction force will be converted to a certain level of the energy by the proposed formula. The target of absorption energy for door trim only and the impact speed of simple impactor are derived theoretically based on the conservation of energy. With calculated speed of dummy and the effective mass of abdomen, the energy allocated in the abdomen area of door trim was calculated. The impactor speed can be calculated based on the equivalent energy of door trim absorbed during the full crash test. With the proposed design procedure for the door trim by a simple impact test method was demonstrated to evaluate the abdominal injury. This paper describes a study that was conducted to determine sensitivity of several design factors for reducing abdominal injury values using the matrix of orthogonal array method. In conclusion, with theoretical considerations and empirical test data, the main objective, standardization of door trim design using the simple impact test method was established.
A novel method of the image processing on irregular triangular meshes
NASA Astrophysics Data System (ADS)
Vishnyakov, Sergey; Pekhterev, Vitaliy; Sokolova, Elizaveta
2018-04-01
The paper describes a novel method of the image processing based on irregular triangular meshes implementation. The triangular mesh is adaptive to the image content, least mean square linear approximation is proposed for the basic interpolation within the triangle. It is proposed to use triangular numbers to simplify using of the local (barycentric) coordinates for the further analysis - triangular element of the initial irregular mesh is to be represented through the set of the four equilateral triangles. This allows to use fast and simple pixels indexing in local coordinates, e.g. "for" or "while" loops for access to the pixels. Moreover, representation proposed allows to use discrete cosine transform of the simple "rectangular" symmetric form without additional pixels reordering (as it is used for shape-adaptive DCT forms). Furthermore, this approach leads to the simple form of the wavelet transform on triangular mesh. The results of the method application are presented. It is shown that advantage of the method proposed is a combination of the flexibility of the image-adaptive irregular meshes with the simple form of the pixel indexing in local triangular coordinates and the using of the common forms of the discrete transforms for triangular meshes. Method described is proposed for the image compression, pattern recognition, image quality improvement, image search and indexing. It also may be used as a part of video coding (intra-frame or inter-frame coding, motion detection).
Sensitive SERS detection of lead ions via DNAzyme based quadratic signal amplification.
Tian, Aihua; Liu, Yu; Gao, Jian
2017-08-15
Highly sensitive detection of Pb 2+ is very necessary for water quality control, clinical toxicology, and industrial monitoring. In this work, a simple and novel DNAzyme-based SERS quadratic amplification method is developed for the detection of Pb 2+ . This strategy possesses some remarkable features compared to the conventional DNAzyme-based SERS methods, which are as follows: (i) Coupled DNAzyme-activated hybridization chain reaction (HCR) with bio barcodes; a quadratic amplification method is designed using the unique catalytic selectivity of DNAzyme. The SERS signal is significantly amplified. This method is rapid with a detection time of 2h. (ii) The problem of high background induced by excess bio barcodes is circumvented by using magnetic beads (MBs) as the carrier of signal-output products, and this sensing system is simple in design and can easily be carried out by simple mixing and incubation. Given the unique and attractive characteristics, a simple and universal strategy is designed to accomplish sensitive detection of Pb 2+ . The detection limit of Pb 2+ via SERS detection is 70 fM, with the linear range from 1.0×10 -13 M to 1.0×10 -7 M. The method can be further extended to the quantitative detection of a variety of targets by replacing the lead-responsive DNAzyme with other functional DNA. Copyright © 2017 Elsevier B.V. All rights reserved.
Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng
2017-01-01
Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.
Time-domain representation of frequency-dependent foundation impedance functions
Safak, E.
2006-01-01
Foundation impedance functions provide a simple means to account for soil-structure interaction (SSI) when studying seismic response of structures. Impedance functions represent the dynamic stiffness of the soil media surrounding the foundation. The fact that impedance functions are frequency dependent makes it difficult to incorporate SSI in standard time-history analysis software. This paper introduces a simple method to convert frequency-dependent impedance functions into time-domain filters. The method is based on the least-squares approximation of impedance functions by ratios of two complex polynomials. Such ratios are equivalent, in the time-domain, to discrete-time recursive filters, which are simple finite-difference equations giving the relationship between foundation forces and displacements. These filters can easily be incorporated into standard time-history analysis programs. Three examples are presented to show the applications of the method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honorio, J.; Goldstein, R.; Honorio, J.
We propose a simple, well grounded classification technique which is suited for group classification on brain fMRI data sets that have high dimensionality, small number of subjects, high noise level, high subject variability, imperfect registration and capture subtle cognitive effects. We propose threshold-split region as a new feature selection method and majority voteas the classification technique. Our method does not require a predefined set of regions of interest. We use average acros ssessions, only one feature perexperimental condition, feature independence assumption, and simple classifiers. The seeming counter-intuitive approach of using a simple design is supported by signal processing and statisticalmore » theory. Experimental results in two block design data sets that capture brain function under distinct monetary rewards for cocaine addicted and control subjects, show that our method exhibits increased generalization accuracy compared to commonly used feature selection and classification techniques.« less
A simple method to extract DNA from hair shafts using enzymatic laundry powder.
Guan, Zheng; Zhou, Yu; Liu, Jinchuan; Jiang, Xiaoling; Li, Sicong; Yang, Shuming; Chen, Ailiang
2013-01-01
A simple method to extract DNA from hair shafts was developed by using enzymatic laundry powder at the first step of the process. The whole extraction can be finished in less than 2 hours. The simple extraction reagent proposed here contains only two cheap components: ordinary enzymatic laundry powder and PCR buffer. After extraction, an ultra sensitive fluorescent nucleic acid stain, PicoGreen, was used for quantifying trace amount of double-stranded DNA in the solution extracted. For further validation of DNA extraction, four primers were employed to amplify DNA microsatellite loci. Both fluorescence spectroscopy and PCR results suggested that this method can extract DNA from hair shafts with good efficiency and repeatability. The study will greatly facilitate the use of hair shafts in future for DNA analyses on genome-wide scale.
A Simple and Reliable Method of Design for Standalone Photovoltaic Systems
NASA Astrophysics Data System (ADS)
Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.
2017-06-01
Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.
Zimmerman, Carl-Ulrich R; Stiedl, Thomas; Spergser, Joachim; Rosengarten, Renate
2014-09-01
A simple method for preparing agar plates is presented, which allows an efficient transfer of Ureaplasma colonies to nitrocellulose membranes for subsequent immunological detection. This simple and reproducible procedure was used to demonstrate antigenic variation in the phase-variable mba-locus of Ureaplasma parvum serovar 3. Copyright © 2014 Elsevier B.V. All rights reserved.
Phonon scattering in nanoscale systems: lowest order expansion of the current and power expressions
NASA Astrophysics Data System (ADS)
Paulsson, Magnus; Frederiksen, Thomas; Brandbyge, Mads
2006-04-01
We use the non-equilibrium Green's function method to describe the effects of phonon scattering on the conductance of nano-scale devices. Useful and accurate approximations are developed that both provide (i) computationally simple formulas for large systems and (ii) simple analytical models. In addition, the simple models can be used to fit experimental data and provide physical parameters.
ERIC Educational Resources Information Center
Edwards, Mark Evan; Weber, Bruce; Bernell, Stephanie
2007-01-01
An existing measure of food insecurity with hunger in the United States may serve as an effective indicator of quality of life. State level differences in that measure can reveal important differences in quality of life across places. In this study, we advocate and demonstrate two simple methods by which analysts can explore state-specific…
A simple method to predict regional fish abundance: an example in the McKenzie River Basin, Oregon
D.J. McGarvey; J.M. Johnston
2011-01-01
Regional assessments of fisheries resources are increasingly called for, but tools with which to perform them are limited. We present a simple method that can be used to estimate regional carrying capacity and apply it to the McKenzie River Basin, Oregon. First, we use a macroecological model to predict trout densities within small, medium, and large streams in the...
Calendar methods of fertility regulation: a rule of thumb.
Colombo, B; Scarpa, B
1996-01-01
"[Many] illiterate women, particularly in the third world, find [it] difficult to apply usual calendar methods for the regulation of fertility. Some of them are even unable to make simple subtractions. In this paper we are therefore trying to evaluate the applicability and the efficiency of an extremely simple rule which entails only [the ability to count] a number of days, and always the same way." (SUMMARY IN ITA) excerpt
A simple, rapid and inexpensive screening method for the identification of Pythium insidiosum.
Tondolo, Juliana Simoni Moraes; Loreto, Erico Silva; Denardi, Laura Bedin; Mario, Débora Alves Nunes; Alves, Sydney Hartz; Santurio, Janio Morais
2013-04-01
Growth of Pythium insidiosum mycelia around minocycline disks (30μg) did not occur within 7days of incubation at 35°C when the isolates were grown on Sabouraud, corn meal, Muller-Hinton or RPMI agar. This technique offers a simple and rapid method for the differentiation of P. insidiosum from true filamentous fungi. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yulkifli; Afandi, Zurian; Yohandri
2018-04-01
Development of gravitation acceleration measurement using simple harmonic motion pendulum method, digital technology and photogate sensor has been done. Digital technology is more practical and optimizes the time of experimentation. The pendulum method is a method of calculating the acceleration of gravity using a solid ball that connected to a rope attached to a stative pole. The pendulum is swung at a small angle resulted a simple harmonic motion. The measurement system consists of a power supply, Photogate sensors, Arduino pro mini and seven segments. The Arduino pro mini receives digital data from the photogate sensor and processes the digital data into the timing data of the pendulum oscillation. The calculation result of the pendulum oscillation time is displayed on seven segments. Based on measured data, the accuracy and precision of the experiment system are 98.76% and 99.81%, respectively. Based on experiment data, the system can be operated in physics experiment especially in determination of the gravity acceleration.
[Developments in preparation and experimental method of solid phase microextraction fibers].
Yi, Xu; Fu, Yujie
2004-09-01
Solid phase microextraction (SPME) is a simple and effective adsorption and desorption technique, which concentrates volatile or nonvolatile compounds from liquid samples or headspace of samples. SPME is compatible with analyte separation and detection by gas chromatography, high performance liquid chromatography, and other instrumental methods. It can provide many advantages, such as wide linear scale, low solvent and sample consumption, short analytical times, low detection limits, simple apparatus, and so on. The theory of SPME is introduced, which includes equilibrium theory and non-equilibrium theory. The novel development of fiber preparation methods and relative experimental techniques are discussed. In addition to commercial fiber preparation, different newly developed fabrication techniques, such as sol-gel, electronic deposition, carbon-base adsorption, high-temperature epoxy immobilization, are presented. Effects of extraction modes, selection of fiber coating, optimization of operating conditions, method sensitivity and precision, and systematical automation, are taken into considerations in the analytical process of SPME. A simple perspective of SPME is proposed at last.
Simple gas chromatographic method for furfural analysis.
Gaspar, Elvira M S M; Lopes, João F
2009-04-03
A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSD<8%), showed good recoveries (77-107%) and good limits of detection (GC-FID: 1.37 microgL(-1) for 2-F, 8.96 microgL(-1) for 5-MF, 6.52 microgL(-1) for 5-HMF; GC-TOF-MS: 0.3, 1.2 and 0.9 ngmL(-1) for 2-F, 5-MF and 5-HMF, respectively). It was applied to different commercial food matrices: honey, white, demerara, brown and yellow table sugars, and white and red balsamic vinegars. This one-step, sensitive and direct method for the analysis of furfurals will contribute to characterise and quantify their presence in the human diet.
Agrawal, Yuvraj; Desai, Aravind; Mehta, Jaysheel
2011-12-01
We aimed to quantify the severity of the hallux valgus based on the lateral sesamoid position and to establish a correlation of our simple assessment method with the conventional radiological assessments. We reviewed one hundred and twenty two dorso-plantar weight bearing radiographs of feet. The intermetatarsal and hallux valgus angles were measured by the conventional methods; and the position of lateral sesamoid in relation to first metatarsal neck was assessed by our new and simple method. Significant correlation was noted between intermetatarsal angle and lateral sesamoid position (Rho 0.74, p < 0.0001); lateral sesamoid position and hallux valgus angle (Rho 0.56, p < 0.0001). Similar trends were noted in different grades of severity of hallux valgus in all the three methods of assessment. Our method of assessing hallux valgus deformity based on the lateral sesamoid position is simple, less time consuming and has statistically significant correlation with that of the established conventional radiological measurements. Copyright © 2011 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs
NASA Astrophysics Data System (ADS)
Lee, Eugene K.; Kurokawa, Yosuke K.; Tu, Robin; George, Steven C.; Khine, Michelle
2015-07-01
Current preclinical screening methods do not adequately detect cardiotoxicity. Using human induced pluripotent stem cell-derived cardiomyocytes (iPS-CMs), more physiologically relevant preclinical or patient-specific screening to detect potential cardiotoxic effects of drug candidates may be possible. However, one of the persistent challenges for developing a high-throughput drug screening platform using iPS-CMs is the need to develop a simple and reliable method to measure key electrophysiological and contractile parameters. To address this need, we have developed a platform that combines machine learning paired with brightfield optical flow as a simple and robust tool that can automate the detection of cardiomyocyte drug effects. Using three cardioactive drugs of different mechanisms, including those with primarily electrophysiological effects, we demonstrate the general applicability of this screening method to detect subtle changes in cardiomyocyte contraction. Requiring only brightfield images of cardiomyocyte contractions, we detect changes in cardiomyocyte contraction comparable to - and even superior to - fluorescence readouts. This automated method serves as a widely applicable screening tool to characterize the effects of drugs on cardiomyocyte function.
Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.
Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot
2007-01-04
The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.
Shin, Younghak; Lee, Seungchan; Ahn, Minkyu; Cho, Hohyun; Jun, Sung Chan; Lee, Heung-No
2015-11-01
One of the main problems related to electroencephalogram (EEG) based brain-computer interface (BCI) systems is the non-stationarity of the underlying EEG signals. This results in the deterioration of the classification performance during experimental sessions. Therefore, adaptive classification techniques are required for EEG based BCI applications. In this paper, we propose simple adaptive sparse representation based classification (SRC) schemes. Supervised and unsupervised dictionary update techniques for new test data and a dictionary modification method by using the incoherence measure of the training data are investigated. The proposed methods are very simple and additional computation for the re-training of the classifier is not needed. The proposed adaptive SRC schemes are evaluated using two BCI experimental datasets. The proposed methods are assessed by comparing classification results with the conventional SRC and other adaptive classification methods. On the basis of the results, we find that the proposed adaptive schemes show relatively improved classification accuracy as compared to conventional methods without requiring additional computation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tian, Kun; Siegel, Gene; Tiwari, Ashutosh
2017-02-01
The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
A simple pore water hydrogen diffusion syringe sampler
Vroblesky, D.A.; Chapelle, F.H.; Bradley, P.M.
2007-01-01
Molecular hydrogen (H2) is an important intermediate product and electron donor in microbial metabolism. Concentrations of dissolved H 2 are often diagnostic of the predominant terminal electron-accepting processes in ground water systems or aquatic sediments. H2 concentrations are routinely measured in ground water monitoring wells but are rarely measured in saturated aquatic sediments due to a lack of simple and practical sampling methods. This report describes the design and development (including laboratory and field testing) of a simple, syringe-based H 2 sampler in (1) saturated, riparian sediments, (2) surface water bed sediments, and (3) packed intervals of a fractured bedrock borehole that are inaccessible by standard pumped methods. ?? 2007 National Ground Water Association.
D. M., Jayaseema; Lai, Jiann-Shiun; Hueng, Dueng-Yuan; Chang, Chen
2013-01-01
Cellular magnetic resonance imaging (MRI) has been well-established for tracking neural progenitor cells (NPC). Superparamagnetic iron oxide nanoparticles (SPIONs) approved for clinical application are the most common agents used for labeling. Conventionally, transfection agents (TAs) were added with SPIONs to facilitate cell labeling because SPIONs in the native unmodified form were deemed inefficient for intracellular labeling. However, compelling evidence also shows that simple SPION incubation is not invariably ineffective. The labeling efficiency can be improved by prolonged incubation and elevated iron doses. The goal of the present study was to establish simple SPION incubation as an efficient intracellular labeling method. To this end, NPCs derived from the neonatal subventricular zone were incubated with SPIONs (Feridex®) and then evaluated in vitro with regard to the labeling efficiency and biological functions. The results showed that, following 48 hours of incubation at 75 µg/ml, nearly all NPCs exhibited visible SPION intake. Evidence from light microscopy, electron microscopy, chemical analysis, and magnetic resonance imaging confirmed the effectiveness of the labeling. Additionally, biological assays showed that the labeled NPCs exhibited unaffected viability, oxidative stress, apoptosis and differentiation. In the demonstrated in vivo cellular MRI experiment, the hypointensities representing the SPION labeled NPCs remained observable throughout the entire tracking period. The findings indicate that simple SPION incubation without the addition of TAs is an efficient intracellular magnetic labeling method. This simple approach may be considered as an alternative approach to the mainstream labeling method that involves the use of TAs. PMID:23468856
Ganger, Michael T; Dietz, Geoffrey D; Ewing, Sarah J
2017-12-01
qPCR has established itself as the technique of choice for the quantification of gene expression. Procedures for conducting qPCR have received significant attention; however, more rigorous approaches to the statistical analysis of qPCR data are needed. Here we develop a mathematical model, termed the Common Base Method, for analysis of qPCR data based on threshold cycle values (C q ) and efficiencies of reactions (E). The Common Base Method keeps all calculations in the logscale as long as possible by working with log 10 (E) ∙ C q , which we call the efficiency-weighted C q value; subsequent statistical analyses are then applied in the logscale. We show how efficiency-weighted C q values may be analyzed using a simple paired or unpaired experimental design and develop blocking methods to help reduce unexplained variation. The Common Base Method has several advantages. It allows for the incorporation of well-specific efficiencies and multiple reference genes. The method does not necessitate the pairing of samples that must be performed using traditional analysis methods in order to calculate relative expression ratios. Our method is also simple enough to be implemented in any spreadsheet or statistical software without additional scripts or proprietary components.
NASA Astrophysics Data System (ADS)
Zaazaa, H. E.; Elzanfaly, E. S.; Soudi, A. T.; Salem, M. Y.
2016-03-01
A new smart simple validated spectrophotometric method was developed for the determination of two drugs one of which is in a very low concentration compared to the other. The method is based on spiking and dilution then simple mathematical manipulation of the absorbance spectra. This method was applied for the determination of a binary mixture of vildagliptin and metformin hydrochloride in the ratio 50:850 in laboratory prepared mixtures containing both drugs in this ratio and in pharmaceutical dosage form with good recoveries. The developed method was validated according to ICH guidelines and can be used for routine quality control testing.
López-Ferrer, Daniel; Hixson, Kim K.; Smallwood, Heather; Squier, Thomas C.; Petritis, Konstantinos; Smith, Richard D.
2009-01-01
A new method that uses immobilized trypsin concomitant with ultrasonic irradiation results in ultra-rapid digestion and thorough 18O labeling for quantitative protein comparisons. The reproducible and highly efficient method provided effective digestions in <1 min with a minimized amount of enzyme required compared to traditional methods. This method was demonstrated for digestion of both simple and complex protein mixtures, including bovine serum albumin, a global proteome extract from the bacteria Shewanella oneidensis, and mouse plasma, as well as 18O labeling of such complex protein mixtures, which validated the application of this method for differential proteomic measurements. This approach is simple, reproducible, cost effective, rapid, and thus well-suited for automation. PMID:19555078
Determination of the transmission coefficients for quantum structures using FDTD method.
Peng, Yangyang; Wang, Xiaoying; Sui, Wenquan
2011-12-01
The purpose of this work is to develop a simple method to incorporate quantum effect in traditional finite-difference time-domain (FDTD) simulators. Witch could make it possible to co-simulate systems include quantum structures and traditional components. In this paper, tunneling transmission coefficient is calculated by solving time-domain Schrödinger equation with a developed FDTD technique, called FDTD-S method. To validate the feasibility of the method, a simple resonant tunneling diode (RTD) structure model has been simulated using the proposed method. The good agreement between the numerical and analytical results proves its accuracy. The effectness and accuracy of this approach makes it a potential method for analysis and design of hybrid systems includes quantum structures and traditional components.
A Simple Experimental Demonstration of Microbial Growth and Interaction.
ERIC Educational Resources Information Center
Wainwright, Milton
1988-01-01
Described is a simple, safe, and inexpensive experiment which allows secondary school pupils to observe how fungi and bacteria grow and interact with each other. Included are discussions of materials, methods, observations, and a historical comment. (Author/CW)
Asuthkar, Swapna; Velineni, Sridhar; Stadlmann, Johannes; Altmann, Friedrich; Sritharan, Manjula
2007-09-01
In an earlier study, based on the ferric enterobactin receptor FepA of Escherichia coli, we identified and modeled a TonB-dependent outer membrane receptor protein (LB191) from the genome of Leptospira interrogans serovar Lai. Based on in silico analysis, we hypothesized that this protein was an iron-dependent hemin-binding protein. In this study, we provide experimental evidence to prove that this protein, termed HbpA (hemin-binding protein A), is indeed an iron-regulated hemin-binding protein. We cloned and expressed the full-length 81-kDa recombinant rHbpA protein and a truncated 55-kDa protein from L. interrogans serovar Lai, both of which bind hemin-agarose. Assay of hemin-associated peroxidase activity and spectrofluorimetric analysis provided confirmatory evidence of hemin binding by HbpA. Immunofluorescence studies by confocal microscopy and the microscopic agglutination test demonstrated the surface localization and the iron-regulated expression of HbpA in L. interrogans. Southern blot analysis confirmed our earlier observation that the hbpA gene was present only in some of the pathogenic serovars and was absent in Leptospira biflexa. Hemin-agarose affinity studies showed another hemin-binding protein with a molecular mass of approximately 44 kDa, whose expression was independent of iron levels. This protein was seen in several serovars, including nonpathogenic L. biflexa. Sequence analysis and immunoreactivity with specific antibodies showed this protein to be LipL41.
Cella, Claudia; Gerges, Irini; Milani, Paolo; Lenardi, Cristina; Argentiere, Simona
2017-02-13
Poly(d,l-lactic-co-glycolic acid) (PLGA) nanoparticles (NPs) are among the most studied systems for drug and gene targeting. So far, the synthesis of stable and uniform PLGA NPs has involved the use of a large excess of polyvinyl surfactants such as poly(vinyl alcohol) (PVA) and polyvinylpyrrolidone (PVP), whose removal requires multistep purification procedures of high ecological and economic impact. Hence the development of environment-friendly and cost-effective synthetic procedures for the synthesis of PLGA NPs would effectively boost their use in clinics. This work aims to address this issue by investigating more efficacious alternatives to the so far employed polyvinyl surfactants. More specifically, we developed an innovative synthetic process to achieve stable and uniformly distributed PLGA NPs that involves the use of calcium stearate (CSt), gaining benefits of its high biocompatibility and efficacy at low concentrations and avoiding consequently expensive purification steps. With the help of minimum quantities of polysorbate 60 and sorbitane monostearate, CSt-stabilized PLGA NPs with different sizes and structures were synthesized. The influence of CSt on the encapsulation efficiency of bioactive molecules has been also investigated. The effective encapsulation of both hydrophobic (curcumin) and hydrophilic (fibrinogen labeled with Alexa647) biomolecules into NPs was demonstrated by confocal microscopy, and their release quantified by spectrofluorimetric analyses. Finally, degradation and cytotoxicity studies showed that CSt stabilized NPs were stable under physiological conditions and with good biocompatibility, thus looking promising for further investigation as controlled release devices.
NASA Astrophysics Data System (ADS)
Johnson, A. M.; Griffiths, J. H.
2007-05-01
At the 2005 Fall Meeting of the American Geophysical Union, Griffiths and Johnson [2005] introduced a method of extracting from the deformation-gradient (and velocity-gradient) tensor the amount and preferred orientation of simple-shear associated with 2-D shear zones and faults. Noting the 2-D is important because the shear zones and faults in Griffiths and Johnson [2005] were assumed non-dilatant and infinitely long, ignoring the scissors- like action along strike associated with shear zones and faults of finite length. Because shear zones and faults can dilate (and contract) normal to their walls and can have a scissors-like action associated with twisting about an axis normal to their walls, the more general method of detecting simple-shear is introduced and called MODES "method of detecting simple-shear." MODES can thus extract from the deformation-gradient (and velocity- gradient) tensor the amount and preferred orientation of simple-shear associated with 3-D shear zones and faults near or far from the Earth's surface, providing improvements and extensions to existing analytical methods used in active tectonics studies, especially strain analysis and dislocation theory. The derivation of MODES is based on one definition and two assumptions: by definition, simple-shear deformation becomes localized in some way; by assumption, the twirl within the deformation-gradient (or the spin within the velocity-gradient) is due to a combination of simple-shear and twist, and coupled with the simple- shear and twist is a dilatation of the walls of shear zones and faults. The preferred orientation is thus the orientation of the plane containing the simple-shear and satisfying the mechanical and kinematical boundary conditions. Results from a MODES analysis are illustrated by means of a three-dimensional diagram, the cricket- ball, which is reminiscent of the seismologist's "beach ball." In this poster, we present the underlying theory of MODES and illustrate how it works by analyzing the three- dimensional displacements measured with the Global Positioning System across the 1999 Chi-Chi earthquake ground rupture in Taiwan. In contrast to the deformation zone in the upper several meters of the ground below the surface detected by Yu et al. [2001], MODES determines the orientation and direction of shift of a shear zone representing the earthquake fault within the upper several hundred or thousand meters of ground below the surface. Thus, one value of the MODES analysis in this case is to provide boundary conditions for dislocation solutions for the subsurface shape of the main rupture during the earthquake.
A simple test for spacetime symmetry
NASA Astrophysics Data System (ADS)
Houri, Tsuyoshi; Yasui, Yukinori
2015-03-01
This paper presents a simple method for investigating spacetime symmetry for a given metric. The method makes use of the curvature conditions that are obtained from the Killing equations. We use the solutions of the curvature conditions to compute an upper bound on the number of Killing vector fields, as well as Killing-Yano (KY) tensors and closed conformal KY tensors. We also use them in the integration of the Killing equations. By means of the method, we thoroughly investigate KY symmetry of type D vacuum solutions such as the Kerr metric in four dimensions. The method is also applied to a large variety of physical metrics in four and five dimensions.
Simulation of ground motion using the stochastic method
Boore, D.M.
2003-01-01
A simple and powerful method for simulating ground motions is to combine parametric or functional descriptions of the ground motion's amplitude spectrum with a random phase spectrum modified such that the motion is distributed over a duration related to the earthquake magnitude and to the distance from the source. This method of simulating ground motions often goes by the name "the stochastic method." It is particularly useful for simulating the higher-frequency ground motions of most interest to engineers (generally, f>0.1 Hz), and it is widely used to predict ground motions for regions of the world in which recordings of motion from potentially damaging earthquakes are not available. This simple method has been successful in matching a variety of ground-motion measures for earthquakes with seismic moments spanning more than 12 orders of magnitude and in diverse tectonic environments. One of the essential characteristics of the method is that it distills what is known about the various factors affecting ground motions (source, path, and site) into simple functional forms. This provides a means by which the results of the rigorous studies reported in other papers in this volume can be incorporated into practical predictions of ground motion.
A comparison of simple shear characterization methods for composite laminates
NASA Technical Reports Server (NTRS)
Yeow, Y. T.; Brinson, H. F.
1978-01-01
Various methods for the shear stress/strain characterization of composite laminates are examined and their advantages and limitations are briefly discussed. Experimental results and the necessary accompanying analysis are then presented and compared for three simple shear characterization procedures. These are the off-axis tensile test method, the (+/- 45 deg)s tensile test method and the (0/90 deg)s symmetric rail shear test method. It is shown that the first technique indicates the shear properties of the graphite/epoxy laminates investigated are fundamentally brittle in nature while the latter two methods tend to indicate that these laminates are fundamentally ductile in nature. Finally, predictions of incrementally determined tensile stress/strain curves utilizing the various different shear behaviour methods as input information are presented and discussed.
A comparison of simple shear characterization methods for composite laminates
NASA Technical Reports Server (NTRS)
Yeow, Y. T.; Brinson, H. F.
1977-01-01
Various methods for the shear stress-strain characterization of composite laminates are examined, and their advantages and limitations are briefly discussed. Experimental results and the necessary accompanying analysis are then presented and compared for three simple shear characterization procedures. These are the off-axis tensile test method, the + or - 45 degs tensile test method and the 0 deg/90 degs symmetric rail shear test method. It is shown that the first technique indicates that the shear properties of the G/E laminates investigated are fundamentally brittle in nature while the latter two methods tend to indicate that the G/E laminates are fundamentally ductile in nature. Finally, predictions of incrementally determined tensile stress-strain curves utilizing the various different shear behavior methods as input information are presented and discussed.
A survey of methods of feasible directions for the solution of optimal control problems
NASA Technical Reports Server (NTRS)
Polak, E.
1972-01-01
Three methods of feasible directions for optimal control are reviewed. These methods are an extension of the Frank-Wolfe method, a dual method devised by Pironneau and Polack, and a Zontendijk method. The categories of continuous optimal control problems are shown as: (1) fixed time problems with fixed initial state, free terminal state, and simple constraints on the control; (2) fixed time problems with inequality constraints on both the initial and the terminal state and no control constraints; (3) free time problems with inequality constraints on the initial and terminal states and simple constraints on the control; and (4) fixed time problems with inequality state space contraints and constraints on the control. The nonlinear programming algorithms are derived for each of the methods in its associated category.
ERIC Educational Resources Information Center
Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe
2018-01-01
In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…
ERIC Educational Resources Information Center
Tamaoka, Katsuo; Asano, Michiko; Miyaoka, Yayoi; Yokosawa, Kazuhiko
2014-01-01
Using the eye-tracking method, the present study depicted pre- and post-head processing for simple scrambled sentences of head-final languages. Three versions of simple Japanese active sentences with ditransitive verbs were used: namely, (1) SO[subscript 1]O[subscript 2]V canonical, (2) SO[subscript 2]O[subscript 1]V single-scrambled, and (3)…
New simple and low-cost methods for periodic checks of Cyclone® Plus Storage Phosphor System.
Edalucci, Elisabetta; Maffione, Anna Margherita; Fornasier, Maria Rosa; De Denaro, Mario; Scian, Giovanni; Dore, Franca; Rubello, Domenico
2017-01-01
The recent large use of the Cyclone® Plus Storage Phosphor System, especially in European countries, as imaging system for quantification of radiochemical purity of radiopharmaceuticals raised the problem of setting the periodic controls as required by European Legislation. We described simple, low-cost methods for Cyclone® Plus quality controls, which can be useful to evaluate the performance measurement of this imaging system.
Simple, benign, aqueous-based amination of polycarbonate surfaces
VanDelinder, Virginia; Wheeler, David R.; Small, Leo J.; ...
2015-03-18
Here we report a simple, safe, environmentally-friendly aqueous method that uses diamines to functionalize a polycarbonate surface with amino groups. We demonstrate the ability of this facile method to serve as a foundation upon which other functionalities may be attached, including anti-fouling coatings and oriented membrane proteins. The use of water as the solvent for the functionalization ensures that solvent induced swelling does not affect the optical or mechanical properties of the polycarbonate.
NASA Astrophysics Data System (ADS)
Yaşar, Emrullah; Yıldırım, Yakup; Zhou, Qin; Moshokoa, Seithuti P.; Ullah, Malik Zaka; Triki, Houria; Biswas, Anjan; Belic, Milivoj
2017-11-01
This paper obtains optical soliton solution to perturbed nonlinear Schrödinger's equation by modified simple equation method. There are four types of nonlinear fibers studied in this paper. They are Anti-cubic law, Quadratic-cubic law, Cubic-quintic-septic law and Triple-power law. Dark and singular soliton solutions are derived. Additional solutions such as singular periodic solutions also fall out of the integration scheme.
SIMPLE: a sequential immunoperoxidase labeling and erasing method.
Glass, George; Papin, Jason A; Mandell, James W
2009-10-01
The ability to simultaneously visualize expression of multiple antigens in cells and tissues can provide powerful insights into cellular and organismal biology. However, standard methods are limited to the use of just two or three simultaneous probes and have not been widely adopted for routine use in paraffin-embedded tissue. We have developed a novel approach called sequential immunoperoxidase labeling and erasing (SIMPLE) that enables the simultaneous visualization of at least five markers within a single tissue section. Utilizing the alcohol-soluble peroxidase substrate 3-amino-9-ethylcarbazole, combined with a rapid non-destructive method for antibody-antigen dissociation, we demonstrate the ability to erase the results of a single immunohistochemical stain while preserving tissue antigenicity for repeated rounds of labeling. SIMPLE is greatly facilitated by the use of a whole-slide scanner, which can capture the results of each sequential stain without any information loss.
NASA Technical Reports Server (NTRS)
Matthews, E.
1984-01-01
A simple method was developed for improved prescription of seasonal surface characteristics and parameterization of land-surface processes in climate models. This method, developed for the Goddard Institute for Space Studies General Circulation Model II (GISS GCM II), maintains the spatial variability of fine-resolution land-cover data while restricting to 8 the number of vegetation types handled in the model. This was achieved by: redefining the large number of vegetation classes in the 1 deg x 1 deg resolution Matthews (1983) vegetation data base as percentages of 8 simple types; deriving roughness length, field capacity, masking depth and seasonal, spectral reflectivity for the 8 types; and aggregating these surface features from the 1 deg x 1 deg resolution to coarser model resolutions, e.g., 8 deg latitude x 10 deg longitude or 4 deg latitude x 5 deg longitude.
A Simple Method to Measure Nematodes' Propulsive Thrust and the Nematode Ratchet.
NASA Astrophysics Data System (ADS)
Bau, Haim; Yuan, Jinzhou; Raizen, David
2015-11-01
Since the propulsive thrust of micro organisms provides a more sensitive indicator of the animal's health and response to drugs than motility, a simple, high throughput, direct measurement of the thrust is desired. Taking advantage of the nematode C. elegans being heavier than water, we devised a simple method to determine the propulsive thrust of the animals by monitoring their velocity when swimming along an inclined plane. We find that the swimming velocity is a linear function of the sin of the inclination angle. This method allows us to determine, among other things, the animas' propulsive thrust as a function of genotype, drugs, and age. Furthermore, taking advantage of the animals' inability to swim over a stiff incline, we constructed a sawteeth ratchet-like track that restricts the animals to swim in a predetermined direction. This research was supported, in part, by NIH NIA Grant 5R03AG042690-02.
Spectral properties of thermal fluctuations on simple liquid surfaces below shot-noise levels.
Aoki, Kenichiro; Mitsui, Takahisa
2012-07-01
We study the spectral properties of thermal fluctuations on simple liquid surfaces, sometimes called ripplons. Analytical properties of the spectral function are investigated and are shown to be composed of regions with simple analytic behavior with respect to the frequency or the wave number. The derived expressions are compared to spectral measurements performed orders of magnitude below shot-noise levels, which is achieved using a novel noise reduction method. The agreement between the theory of thermal surface fluctuations and the experiment is found to be excellent, elucidating the spectral properties of the surface fluctuations. The measurement method requires relatively only a small sample both spatially (few μm) and temporally (~20 s). The method also requires relatively weak light power (~0.5 mW) so that it has a broad range of applicability, including local measurements, investigations of time-dependent phenomena, and noninvasive measurements.
NASA Astrophysics Data System (ADS)
Bang, Sungsik; Rickhey, Felix; Kim, Minsoo; Lee, Hyungyil; Kim, Naksoo
2013-12-01
In this study we establish a process to predict hardening behavior considering the Bauschinger effect for zircaloy-4 sheets. When a metal is compressed after tension in forming, the yield strength decreases. For this reason, the Bauschinger effect should be considered in FE simulations of spring-back. We suggested a suitable specimen size and a method for determining the optimum tightening torque for simple shear tests. Shear stress-strain curves are obtained for five materials. We developed a method to convert the shear load-displacement curve to the effective stress-strain curve with FEA. We simulated the simple shear forward/reverse test using the combined isotropic/kinematic hardening model. We also investigated the change of the load-displacement curve by varying the hardening coefficients. We determined the hardening coefficients so that they follow the hardening behavior of zircaloy-4 in experiments.
Evaporation estimation of rift valley lakes: comparison of models.
Melesse, Assefa M; Abtew, Wossenu; Dessalegne, Tibebe
2009-01-01
Evapotranspiration (ET) accounts for a substantial amount of the water flux in the arid and semi-arid regions of the World. Accurate estimation of ET has been a challenge for hydrologists, mainly because of the spatiotemporal variability of the environmental and physical parameters governing the latent heat flux. In addition, most available ET models depend on intensive meteorological information for ET estimation. Such data are not available at the desired spatial and temporal scales in less developed and remote parts of the world. This limitation has necessitated the development of simple models that are less data intensive and provide ET estimates with acceptable level of accuracy. Remote sensing approach can also be applied to large areas where meteorological data are not available and field scale data collection is costly, time consuming and difficult. In areas like the Rift Valley regions of Ethiopia, the applicability of the Simple Method (Abtew Method) of lake evaporation estimation and surface energy balance approach using remote sensing was studied. The Simple Method and a remote sensing-based lake evaporation estimates were compared to the Penman, Energy balance, Pan, Radiation and Complementary Relationship Lake Evaporation (CRLE) methods applied in the region. Results indicate a good correspondence of the models outputs to that of the above methods. Comparison of the 1986 and 2000 monthly lake ET from the Landsat images to the Simple and Penman Methods show that the remote sensing and surface energy balance approach is promising for large scale applications to understand the spatial variation of the latent heat flux.
Magare, B; Nair, A; Khairnar, K
2017-10-01
Development of a simple and economical air sampler for isolation and enrichment of bacteriophages from air samples. A vacuum filtration unit with simple modifications was used for isolation of bacteriophages from air sampled in the lavatory. Air was sampled at the rate of 62 l min -1 by bubbling into Mcllvaine buffer for 30 min, which was used as bacteriophage solution for enrichment and plaque assessment against individual hosts. Alternatively, the aforementioned phage solution was enriched using a host consortium before plaque assessment. Phages were isolated in the range of 1-12 PFU per ml by the first method, whereas enrichment with host consortium gave phages around 10- to 1000-folds higher in number. Combining with established enrichment method, an improvement of about 10 times in phage isolation efficiency was attained. The method is very useful for studying the natural bacteriophages of air, requiring only a basic microbiological laboratory setup making it simple and economical. This study brings out a simple, economical air sampler for assessing air bacteriophages that can be employed by any microbial laboratory. Although various methods are available for studying bacteriophages in water and soil, very limited are available for air. To the best of our knowledge, the method developed in this study is unique in its design and concept for studying bacteriophages in air. The sampler is sterilizable by autoclaving and maintains a healthy rate of airflow provided by conventional vacuum pumps. The use of a nonspecific 'trapping solution' allows for the qualitative and quantitative study of air bacteriophages. © 2017 The Society for Applied Microbiology.
Small-Scale and Low Cost Electrodes for "Standard" Reduction Potential Measurements
ERIC Educational Resources Information Center
Eggen, Per-Odd; Kvittingen, Lise
2007-01-01
The construction of three simple and inexpensive electrodes, hydrogen, and chlorine and copper electrode is described. This simple method will encourage students to construct their own electrode and better help in understanding precipitation and other electrochemistry concepts.
Zhao, Lingxiao; Pan, Ting; Guo, Dongwei; Wei, Cunxu
2018-01-01
Storage starch in starchy seed influences the seed weight and texture, and determines its applications in food and nonfood industries. Starch granules from different plant sources have significantly different shapes and sizes, and even more the difference exists in the different regions of the same tissue. Therefore, it is very important to in situ investigate the morphology and distribution of starch in the whole seed. However, a simple and rapid method is deficient to prepare the whole section of starchy seed for investigating the morphology and distribution of starch in the whole seeds for a large number of samples. A simple and rapid method was established to prepare the whole section of starchy seed, especially for floury seed, in this study. The whole seeds of translucent and chalky rice, vitreous and floury maize, and normal barley and wheat were sectioned successfully using the newly established method. The iodine-stained section clearly exhibited the shapes and size of starch granules in different regions of seed. The starch granules with different morphologies and iodine-staining colors existed regionally in the seeds of high-amylose rice and maize. The sections of lotus and kidney bean seeds also showed the feasibility of this method for starchy non-cereal seeds. The simple and rapid method was proven effective for preparing the whole sections of starchy seeds. The whole section of seed could be used to investigate the morphology and distribution of starch granules in different regions of the whole seed. The method was especially suitable for large sample numbers to investigate the starch morphology in short time.
A simple and reliable multi-gene transformation method for switchgrass.
Ogawa, Yoichi; Shirakawa, Makoto; Koumoto, Yasuko; Honda, Masaho; Asami, Yuki; Kondo, Yasuhiro; Hara-Nishimura, Ikuko
2014-07-01
A simple and reliable Agrobacterium -mediated transformation method was developed for switchgrass. Using this method, many transgenic plants carrying multiple genes-of-interest could be produced without untransformed escape. Switchgrass (Panicum virgatum L.) is a promising biomass crop for bioenergy. To obtain transgenic switchgrass plants carrying a multi-gene trait in a simple manner, an Agrobacterium-mediated transformation method was established by constructing a Gateway-based binary vector, optimizing transformation conditions and developing a novel selection method. A MultiRound Gateway-compatible destination binary vector carrying the bar selectable marker gene, pHKGB110, was constructed to introduce multiple genes of interest in a single transformation. Two reporter gene expression cassettes, GUSPlus and gfp, were constructed independently on two entry vectors and then introduced into a single T-DNA region of pHKGB110 via sequential LR reactions. Agrobacterium tumefaciens EHA101 carrying the resultant binary vector pHKGB112 and caryopsis-derived compact embryogenic calli were used for transformation experiments. Prolonged cocultivation for 7 days followed by cultivation on media containing meropenem improved transformation efficiency without overgrowth of Agrobacterium, which was, however, not inhibited by cefotaxime or Timentin. In addition, untransformed escape shoots were completely eliminated during the rooting stage by direct dipping the putatively transformed shoots into the herbicide Basta solution for a few seconds, designated as the 'herbicide dipping method'. It was also demonstrated that more than 90 % of the bar-positive transformants carried both reporters delivered from pHKGB112. This simple and reliable transformation method, which incorporates a new selection technique and the use of a MultiRound Gateway-based binary vector, would be suitable for producing a large number of transgenic lines carrying multiple genes.
Boyle, John J.; Kume, Maiko; Wyczalkowski, Matthew A.; Taber, Larry A.; Pless, Robert B.; Xia, Younan; Genin, Guy M.; Thomopoulos, Stavros
2014-01-01
When mechanical factors underlie growth, development, disease or healing, they often function through local regions of tissue where deformation is highly concentrated. Current optical techniques to estimate deformation can lack precision and accuracy in such regions due to challenges in distinguishing a region of concentrated deformation from an error in displacement tracking. Here, we present a simple and general technique for improving the accuracy and precision of strain estimation and an associated technique for distinguishing a concentrated deformation from a tracking error. The strain estimation technique improves accuracy relative to other state-of-the-art algorithms by directly estimating strain fields without first estimating displacements, resulting in a very simple method and low computational cost. The technique for identifying local elevation of strain enables for the first time the successful identification of the onset and consequences of local strain concentrating features such as cracks and tears in a highly strained tissue. We apply these new techniques to demonstrate a novel hypothesis in prenatal wound healing. More generally, the analytical methods we have developed provide a simple tool for quantifying the appearance and magnitude of localized deformation from a series of digital images across a broad range of disciplines. PMID:25165601
Simple method for self-referenced and lable-free biosensing by using a capillary sensing element.
Liu, Yun; Chen, Shimeng; Liu, Qiang; Liu, Zigeng; Wei, Peng
2017-05-15
We demonstrated a simple method for self-reference and label free biosensing based on a capillary sensing element and common optoelectronic devices. The capillary sensing element is illuminated by a light-emitting diode (LED) light source and detected by a webcam. Part of gold film that deposited on the tubing wall is functionalized to carry on the biological information in the excited SPR modes. The end face of the capillary was monitored and separate regions of interest (ROIs) were selected as the measurement channel and the reference channel. In the ROIs, the biological information can be accurately extracted from the image by simple image processing. Moreover, temperature fluctuation, bulk RI fluctuation, light source fluctuation and other factors can be effectively compensated during detection. Our biosensing device has a sensitivity of 1145%/RIU and a resolution better than 5.287 × 10 -4 RIU, considering a 0.79% noise level. We apply it for concanavalin A (Con A) biological measurement, which has an approximately linear response to the specific analyte concentration. This simple method provides a new approach for multichannel SPR sensing and reference-compensated calibration of SPR signal for label-free detection.
NASA Astrophysics Data System (ADS)
Pollard, David; Chang, Won; Haran, Murali; Applegate, Patrick; DeConto, Robert
2016-05-01
A 3-D hybrid ice-sheet model is applied to the last deglacial retreat of the West Antarctic Ice Sheet over the last ˜ 20 000 yr. A large ensemble of 625 model runs is used to calibrate the model to modern and geologic data, including reconstructed grounding lines, relative sea-level records, elevation-age data and uplift rates, with an aggregate score computed for each run that measures overall model-data misfit. Two types of statistical methods are used to analyze the large-ensemble results: simple averaging weighted by the aggregate score, and more advanced Bayesian techniques involving Gaussian process-based emulation and calibration, and Markov chain Monte Carlo. The analyses provide sea-level-rise envelopes with well-defined parametric uncertainty bounds, but the simple averaging method only provides robust results with full-factorial parameter sampling in the large ensemble. Results for best-fit parameter ranges and envelopes of equivalent sea-level rise with the simple averaging method agree well with the more advanced techniques. Best-fit parameter ranges confirm earlier values expected from prior model tuning, including large basal sliding coefficients on modern ocean beds.
Durán, Gema M; Contento, Ana M; Ríos, Ángel
2013-11-01
Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L(-1). The lineal range was between 10-5×10(3) ng L(-1). RSD values in the range of 71-102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence. Copyright © 2013 Elsevier B.V. All rights reserved.
A Rapid and Simple Real-Time PCR Assay for Detecting Foodborne Pathogenic Bacteria in Human Feces.
Hanabara, Yutaro; Ueda, Yutaka
2016-11-22
A rapid, simple method for detecting foodborne pathogenic bacteria in human feces is greatly needed. Here, we examined the efficacy of a method that employs a combination of a commercial PCR master mix, which is insensitive to PCR inhibitors, and a DNA extraction method which used sodium dodecyl benzene sulfonate (SDBS), and Tween 20 to counteract the inhibitory effects of SDBS on the PCR assay. This method could detect the target genes (stx1 and stx2 of enterohemorrhagic Escherichia coli, invA of Salmonella Enteritidis, tdh of Vibrio parahaemolyticus, gyrA of Campylobacter jejuni, ceuE of Campylobacter coli, SEA of Staphylococcus aureus, ces of Bacillus cereus, and cpe of Clostridium perfringens) in a fecal suspension containing 1.0 × 10 1 to 1.0 × 10 3 CFU/ml. Furthermore, the assay was neither inhibited nor influenced by individual differences among the fecal samples of 10 subjects or fecal concentration (40-160 mg/ml in the fecal suspension). When we attempted to detect the genes of pathogenic bacteria in 4 actual clinical cases, we found that this method was more sensitive than standard culture method. These results showed that this assay is a rapid, simple detection method for foodborne pathogenic bacteria in human feces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Yongpeng; Northwest Institute of Nuclear Technology, P.O. Box 69-13, Xi'an 710024; Liu Guozhi
In this paper, the Child-Langmuir law and Langmuir-Blodgett law are generalized to the relativistic regime by a simple method. Two classical laws suitable for the nonrelativistic regime are modified to simple approximate expressions applicable for calculating the space-charge-limited currents of one-dimensional steady-state planar diodes and coaxial diodes under the relativistic regime. The simple approximate expressions, extending the Child-Langmuir law and Langmuir-Blodgett law to fit the full range of voltage, have small relative errors less than 1% for one-dimensional planar diodes and less than 5% for coaxial diodes.
Generalized Lotka—Volterra systems connected with simple Lie algebras
NASA Astrophysics Data System (ADS)
Charalambides, Stelios A.; Damianou, Pantelis A.; Evripidou, Charalambos A.
2015-06-01
We devise a new method for producing Hamiltonian systems by constructing the corresponding Lax pairs. This is achieved by considering a larger subset of the positive roots than the simple roots of the root system of a simple Lie algebra. We classify all subsets of the positive roots of the root system of type An for which the corresponding Hamiltonian systems are transformed, via a simple change of variables, to Lotka-Volterra systems. For some special cases of subsets of the positive roots of the root system of type An, we produce new integrable Hamiltonian systems.
Kanlaya, Rattiyaporn; Thongboonkerd, Visith
2016-08-01
Conventional method to purify/concentrate dengue virus (DENV) is time-consuming with low virus recovery yield. Herein, we applied cellufine sulfate column chromatography to purify/concentrate DENV based on the mimicry between heparan sulfate and DENV envelope protein. Comparative analysis demonstrated that this new method offered higher purity (as determined by less contamination of bovine serum albumin) and recovery yield (as determined by greater infectivity). Moreover, overall duration used for cellufine sulfate column chromatography to purify/concentrate DENV was approximately 1/20 of that of conventional method. Therefore, cellufine sulfate column chromatography serves as a simple, rapid, and effective alternative method for DENV purification/concentration. Copyright © 2016 Elsevier B.V. All rights reserved.
A facile fluorescent "turn-off" method for sensing paraquat based on pyranine-paraquat interaction
NASA Astrophysics Data System (ADS)
Zhao, Zuzhi; Zhang, Fengwei; Zhang, Zipin
2018-06-01
Development of a technically simple yet effective method for paraquat (PQ) detection is of great importance due to its high clinical and environmental relevance. In this study, we developed a pyranine-based fluorescent "turn-off" method for PQ sensing based on pyranine-PQ interaction. We investigated the dependence of analytical performance of this method on the experimental conditions, such as the ion strength, medium pH, and so on. Under the optimized conditions, the method is sensitive and selective, and could be used for PQ detection in real-world sample. This study essentially provides a readily accessible fluorescent system for PQ sensing which is cheap, robust, and technically simple, and it is envisaged to find more interesting clinical and environmental applications.
NASA Astrophysics Data System (ADS)
Metusala, D.
2017-07-01
This alternative method provides a simple and faster procedure for preparing cross-sections of leaves and roots in herbaceous plants, especially for living specimens of orchids (Orchidaceae). This method used a clamp-on hand sliding microtome to make cross-sections of leaves and roots, with sections preserved inside the microtubes containing preservation liquid. This preservation technique allowed the sections to be restained and to be used for further usage in future. This method was more practical than the paraffin embedding method because it does not need the additional steps of paraffin embedding and deparaffinization. It may also provide better cross-section results than free-hand sectioning method. The procedure is very feasible and is recommended for use in plant anatomy observation.
Scalable Track Detection in SAR CCD Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chow, James G; Quach, Tu-Thach
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images ta ken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are often too simple to capture natural track features such as continuity and parallelism. We present a simple convolutional network architecture consisting of a series of 3-by-3 convolutions to detect tracks. The network is trained end-to-end to learn natural track features entirely from data. The network is computationally efficient and improves the F-score on a standard dataset to 0.988,more » up fr om 0.907 obtained by the current state-of-the-art method.« less
Code Samples Used for Complexity and Control
NASA Astrophysics Data System (ADS)
Ivancevic, Vladimir G.; Reid, Darryn J.
2015-11-01
The following sections are included: * MathematicaⓇ Code * Generic Chaotic Simulator * Vector Differential Operators * NLS Explorer * 2C++ Code * C++ Lambda Functions for Real Calculus * Accelerometer Data Processor * Simple Predictor-Corrector Integrator * Solving the BVP with the Shooting Method * Linear Hyperbolic PDE Solver * Linear Elliptic PDE Solver * Method of Lines for a Set of the NLS Equations * C# Code * Iterative Equation Solver * Simulated Annealing: A Function Minimum * Simple Nonlinear Dynamics * Nonlinear Pendulum Simulator * Lagrangian Dynamics Simulator * Complex-Valued Crowd Attractor Dynamics * Freeform Fortran Code * Lorenz Attractor Simulator * Complex Lorenz Attractor * Simple SGE Soliton * Complex Signal Presentation * Gaussian Wave Packet * Hermitian Matrices * Euclidean L2-Norm * Vector/Matrix Operations * Plain C-Code: Levenberg-Marquardt Optimizer * Free Basic Code: 2D Crowd Dynamics with 3000 Agents
An investigation of improved airbag performance by vent control and gas injection
NASA Astrophysics Data System (ADS)
Lee, Calvin; Rosato, Nick; Lai, Francis
Airbags are currently being investigated as an impact energy absorber for U.S. Army airdrop. Simple airbags with constant vent areas have been found to be unsatisfactory in yielding high G forces. In this paper, a method of controlling the vent area and a method of injecting gas into the airbag during its compression stroke to improve airbag performance are presented. Theoretical analysis of complex airbags using these two methods show that they provide lower G forces than simple airbags. Vertical drop tests of a vent-control airbag confirm this result. Gas-injection airbags are currently being tested.
New pharmacokinetic methods. III. Two simple test for deep pool effect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Browne, T.R.; Greenblatt, D.J.; Schumacher, G.E.
1990-08-01
If a portion of administered drug is distributed into a deep peripheral compartment, the drug's actual elimination half-life during the terminal exponential phase of elimination may be longer than determined by a single dose study or a tracer dose study (deep pool effect). Two simple methods of testing for deep pool effect applicable to drugs with either linear or nonlinear pharmacokinetic properties are described. The methods are illustrated with stable isotope labeled (13C15N2) tracer dose studies of phenytoin. No significant (P less than .05) deep pool effect was detected.
Simple method for assembly of CRISPR synergistic activation mediator gRNA expression array.
Vad-Nielsen, Johan; Nielsen, Anders Lade; Luo, Yonglun
2018-05-20
When studying complex interconnected regulatory networks, effective methods for simultaneously manipulating multiple genes expression are paramount. Previously, we have developed a simple method for generation of an all-in-one CRISPR gRNA expression array. We here present a Golden Gate Assembly-based system of synergistic activation mediator (SAM) compatible CRISPR/dCas9 gRNA expression array for the simultaneous activation of multiple genes. Using this system, we demonstrated the simultaneous activation of the transcription factors, TWIST, SNAIL, SLUG, and ZEB1 a human breast cancer cell line. Copyright © 2018 Elsevier B.V. All rights reserved.
Watson, K.; Hummer-Miller, S.
1981-01-01
A method based solely on remote sensing data has been developed to estimate those meteorological effects which are required for thermal-inertia mapping. It assumes that the atmospheric fluxes are spatially invariant and that the solar, sky, and sensible heat fluxes can be approximated by a simple mathematical form. Coefficients are determined from least-squares method by fitting observational data to our thermal model. A comparison between field measurements and the model-derived flux shows the type of agreement which can be achieved. An analysis of the limitations of the method is also provided. ?? 1981.
Stockert, J C; Del Castillo, P
1990-01-01
On account of the rigidity and compact structure of the hyaline cartilage, unfixed or formaldehyde fixed samples of this tissue can be directly sectioned by using a conventional ultramicrotome and a glass knife. This simple method allows to obtain microscopical sections from unembedded cartilage blocks, which show a well preserved histological structure and are very suitable to carry out morphological and histochemical studies on chondrocytes and cartilaginous matrix.
Carrasco-Pancorbo, Alegria; Gómez-Caravaca, Ana Maria; Cerretani, Lorenzo; Bendini, Alessandra; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto
2006-09-01
We have devised a simple and rapid capillary electrophoretic method which provides the analyst with a useful tool for the characterization of the polyphenolic fraction of extra-virgin olive oil. This method that uses a capillary with 50 microm id and a total length of 47 cm (40 cm to the detector) with a detection window of 100 x 200 microm, and a buffer solution containing 45 mM of sodium tetraborate pH 9.3 offers valuable information about all the families of compounds present in the polar fraction of the olive oil. The detection was carried out by UV absorption at 200, 240, 280, and 330 nm in order to facilitate the identification of the compounds. Concretely, the method permits the identification of simple phenols, lignans, complex phenols (isomeric forms of secoiridoids), phenolic acids, and flavonoids in the SPE-Diol extracts from extra-virgin olive oil in a short time (less than 10 min) and provides a satisfactory resolution. Peak identification was done by comparing both migration time and spectral data obtained from olive oil samples and standards (commercial or isolated (by HPLC-MS) standards), with spiked methanol-water extracts of olive oil with HPLC-collected compounds and commercially available standards at several concentration levels, studying the information of the electropherograms obtained at several wavelengths and also using the information previously reported.
A simple method to design non-collision relative orbits for close spacecraft formation flying
NASA Astrophysics Data System (ADS)
Jiang, Wei; Li, JunFeng; Jiang, FangHua; Bernelli-Zazzera, Franco
2018-05-01
A set of linearized relative motion equations of spacecraft flying on unperturbed elliptical orbits are specialized for particular cases, where the leader orbit is circular or equatorial. Based on these extended equations, we are able to analyze the relative motion regulation between a pair of spacecraft flying on arbitrary unperturbed orbits with the same semi-major axis in close formation. Given the initial orbital elements of the leader, this paper presents a simple way to design initial relative orbital elements of close spacecraft with the same semi-major axis, thus preventing collision under non-perturbed conditions. Considering the mean influence of J 2 perturbation, namely secular J 2 perturbation, we derive the mean derivatives of orbital element differences, and then expand them to first order. Thus the first order expansion of orbital element differences can be added to the relative motion equations for further analysis. For a pair of spacecraft that will never collide under non-perturbed situations, we present a simple method to determine whether a collision will occur when J 2 perturbation is considered. Examples are given to prove the validity of the extended relative motion equations and to illustrate how the methods presented can be used. The simple method for designing initial relative orbital elements proposed here could be helpful to the preliminary design of the relative orbital elements between spacecraft in a close formation, when collision avoidance is necessary.
Hoque, Sheikh Ariful; Hoshino, Hiroo; Anwar, Kazi Selim; Tanaka, Atsushi; Shinagawa, Masahiko; Hayakawa, Yuko; Okitsu, Shoko; Wada, Yuichi; Ushijima, Hiroshi
2013-02-01
The postnatal transmission of human immunodeficiency virus (HIV) from mothers to children occurs through breastfeeding. Although heat treatment of expressed breast milk is a promising approach to make breastfeeding safer, it is still not popular, mainly because the recommended procedures are difficult to follow, or time-consuming, or because mothers do not know which temperature is sufficient to inactivate HIV without destroying the nutritional elements of milk. To overcome these drawbacks, a simple and rapid method of heat treatment that a mother could perform with regular household materials applying her day-to-day art of cooking was examined. This structured experiment has demonstrated that both cell-free and cell-associated HIV type 1 (HIV-1) in expressed breast milk could be inactivated once the temperature of milk reached 65°C. Furthermore, a heating method as simple as heating the milk in a pan over a stove to 65°C inhibited HIV-1 transmission retaining milk's nutritional key elements, for example, total protein, IgG, IgA, and vitamin B(12) . This study has highlighted a simple, handy, and cost-effective method of heat treatment of expressed breast milk that mothers infected with HIV could apply easily and with more confidence. Copyright © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Dabiri, M.; Ghafouri, M.; Rohani Raftar, H. R.; Björk, T.
2018-03-01
Methods to estimate the strain-life curve, which were divided into three categories: simple approximations, artificial neural network-based approaches and continuum damage mechanics models, were examined, and their accuracy was assessed in strain-life evaluation of a direct-quenched high-strength steel. All the prediction methods claim to be able to perform low-cycle fatigue analysis using available or easily obtainable material properties, thus eliminating the need for costly and time-consuming fatigue tests. Simple approximations were able to estimate the strain-life curve with satisfactory accuracy using only monotonic properties. The tested neural network-based model, although yielding acceptable results for the material in question, was found to be overly sensitive to the data sets used for training and showed an inconsistency in estimation of the fatigue life and fatigue properties. The studied continuum damage-based model was able to produce a curve detecting early stages of crack initiation. This model requires more experimental data for calibration than approaches using simple approximations. As a result of the different theories underlying the analyzed methods, the different approaches have different strengths and weaknesses. However, it was found that the group of parametric equations categorized as simple approximations are the easiest for practical use, with their applicability having already been verified for a broad range of materials.
NASA Astrophysics Data System (ADS)
Ivković, Saša S.; Marković, Marija Z.; Ivković, Dragica Ž.; Cvetanović, Nikola
2017-09-01
Equivalent series resistance (ESR) represents the measurement of total energy loss in a capacitor. In this paper a simple method for measuring the ESR of ceramic capacitors based on the analysis of the oscillations of an LCR circuit is proposed. It is shown that at frequencies under 3300 Hz, the ESR is directly proportional to the period of oscillations. Based on the determined dependence of the ESR on the period, a method is devised and tested for measuring coil inductance. All measurements were performed using the standard equipment found in student laboratories, which makes both methods very suitable for implementation at high school and university levels.
Automatic classification of bottles in crates
NASA Astrophysics Data System (ADS)
Aas, Kjersti; Eikvil, Line; Bremnes, Dag; Norbryhn, Andreas
1995-03-01
This paper presents a statistical method for classification of bottles in crates for use in automatic return bottle machines. For the automatons to reimburse the correct deposit, a reliable recognition is important. The images are acquired by a laser range scanner coregistering the distance to the object and the strength of the reflected signal. The objective is to identify the crate and the bottles from a library with a number of legal types. The bottles with significantly different size are separated using quite simple methods, while a more sophisticated recognizer is required to distinguish the more similar bottle types. Good results have been obtained when testing the method developed on bottle types which are difficult to distinguish using simple methods.
NASA Technical Reports Server (NTRS)
Campbell, John P; Mckinney, Marion O
1952-01-01
A summary of methods for making dynamic lateral stability and response calculations and for estimating the aerodynamic stability derivatives required for use in these calculations is presented. The processes of performing calculations of the time histories of lateral motions, of the period and damping of these motions, and of the lateral stability boundaries are presented as a series of simple straightforward steps. Existing methods for estimating the stability derivatives are summarized and, in some cases, simple new empirical formulas are presented. Detailed estimation methods are presented for low-subsonic-speed conditions but only a brief discussion and a list of references are given for transonic and supersonic speed conditions.
A Simple Combinatorial Codon Mutagenesis Method for Targeted Protein Engineering.
Belsare, Ketaki D; Andorfer, Mary C; Cardenas, Frida S; Chael, Julia R; Park, Hyun June; Lewis, Jared C
2017-03-17
Directed evolution is a powerful tool for optimizing enzymes, and mutagenesis methods that improve enzyme library quality can significantly expedite the evolution process. Here, we report a simple method for targeted combinatorial codon mutagenesis (CCM). To demonstrate the utility of this method for protein engineering, CCM libraries were constructed for cytochrome P450 BM3 , pfu prolyl oligopeptidase, and the flavin-dependent halogenase RebH; 10-26 sites were targeted for codon mutagenesis in each of these enzymes, and libraries with a tunable average of 1-7 codon mutations per gene were generated. Each of these libraries provided improved enzymes for their respective transformations, which highlights the generality, simplicity, and tunability of CCM for targeted protein engineering.
Xuli, Wu; Weiyi, He; Ji, Kunmei; Wenpu, Wan; Dongsheng, Hu; Hui, Wu; Xinpin, Luo; Zhigang, Liu
2013-03-01
The ingredient declaration on food labels assumes paramount importance in the protection of food-allergic consumers. China has not implemented Food allergen labeling. A gold immunochromatography assay (GICA) was developed using 2 monoclonal antibodies (mAb) against the milk allergen β-lactoglobulin in this study. The GICA was specific for pure milk samples with a sensitivity of 0.2 ng/mL. Milk protein traces extracted from 110 food products were detected by this method. The labels of 106 were confirmed by our GICA method: 57 food samples originally labeled as containing milk were positive for β-lactoglobulin and 49 food samples labeled as not containing milk were negative for β-lactoglobulin. However, 3 food samples falsely labeled as containing milk were found to contain no β-lactoglobulin whereas 1 food sample labeled as not containing milk actually contained β-lactoglobulin. First, these negatives could be because of the addition of a casein fraction. Second, some countries demand that food manufacturers label all ingredients derived from milk as "containing milk" even though the ingredients contain no detectable milk protein by any method. Our GICA method could thus provide a fast and simple method for semiquantitatation of β-lactoglobulin in foods. The present method provides a fast, simple, semiquantitative method for the determination of milk allergens in foods. © 2013 Institute of Food Technologists®
A Simple Plant Growth Analysis.
ERIC Educational Resources Information Center
Oxlade, E.
1985-01-01
Describes the analysis of dandelion peduncle growth based on peduncle length, epidermal cell dimensions, and fresh/dry mass. Methods are simple and require no special apparatus or materials. Suggests that limited practical work in this area may contribute to students' lack of knowledge on plant growth. (Author/DH)
Optimized theory for simple and molecular fluids.
Marucho, M; Montgomery Pettitt, B
2007-03-28
An optimized closure approximation for both simple and molecular fluids is presented. A smooth interpolation between Perkus-Yevick and hypernetted chain closures is optimized by minimizing the free energy self-consistently with respect to the interpolation parameter(s). The molecular version is derived from a refinement of the method for simple fluids. In doing so, a method is proposed which appropriately couples an optimized closure with the variant of the diagrammatically proper integral equation recently introduced by this laboratory [K. M. Dyer et al., J. Chem. Phys. 123, 204512 (2005)]. The simplicity of the expressions involved in this proposed theory has allowed the authors to obtain an analytic expression for the approximate excess chemical potential. This is shown to be an efficient tool to estimate, from first principles, the numerical value of the interpolation parameters defining the aforementioned closure. As a preliminary test, representative models for simple fluids and homonuclear diatomic Lennard-Jones fluids were analyzed, obtaining site-site correlation functions in excellent agreement with simulation data.
Li, Jie; Li, Rui; You, Leiming; Xu, Anlong; Fu, Yonggui; Huang, Shengfeng
2015-01-01
Switching between different alternative polyadenylation (APA) sites plays an important role in the fine tuning of gene expression. New technologies for the execution of 3’-end enriched RNA-seq allow genome-wide detection of the genes that exhibit significant APA site switching between different samples. Here, we show that the independence test gives better results than the linear trend test in detecting APA site-switching events. Further examination suggests that the discrepancy between these two statistical methods arises from complex APA site-switching events that cannot be represented by a simple change of average 3’-UTR length. In theory, the linear trend test is only effective in detecting these simple changes. We classify the switching events into four switching patterns: two simple patterns (3’-UTR shortening and lengthening) and two complex patterns. By comparing the results of the two statistical methods, we show that complex patterns account for 1/4 of all observed switching events that happen between normal and cancerous human breast cell lines. Because simple and complex switching patterns may convey different biological meanings, they merit separate study. We therefore propose to combine both the independence test and the linear trend test in practice. First, the independence test should be used to detect APA site switching; second, the linear trend test should be invoked to identify simple switching events; and third, those complex switching events that pass independence testing but fail linear trend testing can be identified. PMID:25875641
A simple method for measurement of maximal downstroke power on friction-loaded cycle ergometer.
Morin, Jean-Benoît; Belli, Alain
2004-01-01
The aim of this study was to propose and validate a post-hoc correction method to obtain maximal power values taking into account inertia of the flywheel during sprints on friction-loaded cycle ergometers. This correction method was obtained from a basic postulate of linear deceleration-time evolution during the initial phase (until maximal power) of a sprint and included simple parameters as flywheel inertia, maximal velocity, time to reach maximal velocity and friction force. The validity of this model was tested by comparing measured and calculated maximal power values for 19 sprint bouts performed by five subjects against 0.6-1 N kg(-1) friction loads. Non-significant differences between measured and calculated maximal power (1151+/-169 vs. 1148+/-170 W) and a mean error index of 1.31+/-1.20% (ranging from 0.09% to 4.20%) showed the validity of this method. Furthermore, the differences between measured maximal power and power neglecting inertia (20.4+/-7.6%, ranging from 9.5% to 33.2%) emphasized the usefulness of power correcting in studies about anaerobic power which do not include inertia, and also the interest of this simple post-hoc method.
Alessandri, Stefano
2017-01-01
Introduction: Some release of radionuclides into the environment can be expected from the growing number of nuclear plants, either in or out of service. The citizen and the big organization could be both interested in simple and innovative methods for checking the radiological safety of their environment and of commodities, starting from foods. Methods: In this work three methods to detect radioactivity are briefly compared focusing on the most recent, which converts a smartphone into a radiation counter. Results: The results of a simple sensitivity test are presented showing the measure of the activity of reference sources put at different distances from each sensor. Discussion: The three methods are discussed in terms of availability, technology, sensitivity, resolution and usefulness. The reported results can be usefully transferred into a radiological emergency scenario and they also offer some interesting implication for our current everyday life, but show that the hardware of the tested smart-phone can detect only high levels of radioactivity. However the technology could be interesting to build a working detection and measurement chain which could start from a diffused and networked first screening before the final high resolution analysis. PMID:28744409
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Jianying; Dann, Geoffrey P.; Shi, Tujin
2012-03-10
Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides.more » Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.« less
Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini
2016-11-15
For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Percutaneous Method of Management of Simple Bone Cyst
Lakhwani, O. P.
2013-01-01
Introduction. Simple bone cyst or unicameral bone cysts are benign osteolytic lesions seen in metadiaphysis of long bones in growing children. Various treatment modalities with variable outcomes have been described in the literature. The case report illustrates the surgical technique of minimally invasive method of treatment. Case Study. A 14-year-old boy was diagnosed as active simple bone cyst proximal humerus with pathological fracture. The patient was treated by minimally invasive percutaneous curettage with titanium elastic nail (TENS) and allogenic bone grafting mixed with bone marrow under image intensifier guidance. Results. Pathological fracture was healed and allograft filled in the cavity was well taken up. The patient achieved full range of motion with successful outcome. Conclusion. Minimally invasive percutaneous method using elastic intramedullary nail gives benefit of curettage cyst decompression and stabilization of fracture. Allogenic bone graft fills the cavity and healing of lesion by osteointegration. This method may be considered with advantage of minimally invasive technique in treatment of benign cystic lesions of bone, and the level of evidence was therapeutic level V. PMID:23819089
Zhu, Tang; Cai, Chao; Duan, Chunting; Zhai, Shuai; Liang, Songmiao; Jin, Yan; Zhao, Ning; Xu, Jian
2015-07-01
A simple, rapid (10 s) and scalable method to fabricate superhydrophobic polypropylene (PP) fabrics is developed by swelling the fabrics in cyclohexane/heptane mixture at 80 °C. The recrystallization of the swollen macromolecules on the fiber surface contributes to the formation of submicron protuberances, which increase the surface roughness dramatically and result in superhydrophobic behavior. The superhydrophobic PP fabrics possess excellent repellency to blood, urine, milk, coffee, and other common liquids, and show good durability and robustness, such as remarkable resistances to water penetration, abrasion, acidic/alkaline solution, and boiling water. The excellent comprehensive performance of the superhydrophobic PP fabrics indicates their potential applications as oil/water separation materials, protective garments, diaper pads, or other medical and health supplies. This simple, fast and low cost method operating at a relatively low temperature is superior to other reported techniques for fabricating superhydrophobic PP materials as far as large scale manufacturing is considered. Moreover, the proposed method is applicable for preparing superhydrophobic PP films and sheets as well.
Synapse fits neuron: joint reduction by model inversion.
van der Scheer, H T; Doelman, A
2017-08-01
In this paper, we introduce a novel simplification method for dealing with physical systems that can be thought to consist of two subsystems connected in series, such as a neuron and a synapse. The aim of our method is to help find a simple, yet convincing model of the full cascade-connected system, assuming that a satisfactory model of one of the subsystems, e.g., the neuron, is already given. Our method allows us to validate a candidate model of the full cascade against data at a finer scale. In our main example, we apply our method to part of the squid's giant fiber system. We first postulate a simple, hypothetical model of cell-to-cell signaling based on the squid's escape response. Then, given a FitzHugh-type neuron model, we derive the verifiable model of the squid giant synapse that this hypothesis implies. We show that the derived synapse model accurately reproduces synaptic recordings, hence lending support to the postulated, simple model of cell-to-cell signaling, which thus, in turn, can be used as a basic building block for network models.
Nelson, Jonathan M.; Kinzel, Paul J.; Schmeeckle, Mark Walter; McDonald, Richard R.; Minear, Justin T.
2016-01-01
Noncontact methods for measuring water-surface elevation and velocity in laboratory flumes and rivers are presented with examples. Water-surface elevations are measured using an array of acoustic transducers in the laboratory and using laser scanning in field situations. Water-surface velocities are based on using particle image velocimetry or other machine vision techniques on infrared video of the water surface. Using spatial and temporal averaging, results from these methods provide information that can be used to develop estimates of discharge for flows over known bathymetry. Making such estimates requires relating water-surface velocities to vertically averaged velocities; the methods here use standard relations. To examine where these relations break down, laboratory data for flows over simple bumps of three amplitudes are evaluated. As anticipated, discharges determined from surface information can have large errors where nonhydrostatic effects are large. In addition to investigating and characterizing this potential error in estimating discharge, a simple method for correction of the issue is presented. With a simple correction based on bed gradient along the flow direction, remotely sensed estimates of discharge appear to be viable.
Biswas, C; Dey, P; Satpathy, S; Sarkar, S K; Bera, A; Mahapatra, B S
2013-02-01
A simple method was developed for isolating DNA from jute seed, which contains high amounts of mucilage and secondary metabolites, and a PCR protocol was standardized for detecting the seedborne pathogen Macrophomina phaseolina. The cetyl trimethyl ammonium bromide method was modified with increased salt concentration and a simple sodium acetate treatment to extract genomic as well as fungal DNA directly from infected jute seed. The Miniprep was evaluated along with five other methods of DNA isolation in terms of yield and quality of DNA and number of PCR positive samples. The Miniprep consistently recovered high amounts of DNA with good spectral qualities at A260/A280. The DNA isolated from jute seed was found suitable for PCR amplification. Macrophomina phaseolina could be detected by PCR from artificially inoculated as well as naturally infected jute seeds. The limit of PCR-based detection of M. phaseolina in jute seed was determined to be 0·62 × 10(-7) CFU g(-1) seed. © 2012 The Society for Applied Microbiology.
Simple detection of residual enrofloxacin in meat products using microparticles and biochips.
Ha, Mi-Sun; Chung, Myung-Sub; Bae, Dong-Ho
2016-05-01
A simple and sensitive method for detecting enrofloxacin, a major veterinary fluoroquinolone, was developed. Monoclonal antibody specific for enrofloxacin was immobilised on a chip and fluorescent dye-labelled microparticles were covalently bound to the enrofloxacin molecules. Enrofloxacin in solution competes with the microparticle-immobilised enrofloxacin (enroMPs) to bind to the antibody on the chip. The presence of enrofloxacin was verified by detecting the fluorescence of enrofloxacin-bound microparticles. Under optimum conditions, a high dynamic range was achieved at enrofloxacin concentrations ranging from 1 to 1000 μg kg(-1). The limits of detection and quantification for standard solutions were 5 and 20 μg kg(-1) respectively, which are markedly lower than the maximum residue limit. Using simple extraction methods, recoveries from fortified beef, pork and chicken samples were 43.4-62.3%. This novel method also enabled approximate quantification of enrofloxacin concentration: the enroMP signal intensity decreased with increasing enrofloxacin concentration. Because of its sensitivity, specificity, simplicity and rapidity, the method described herein will facilitate the detection and approximate quantification of enrofloxacin residues in foods in a high-throughput manner.
Investigating the Group-Level Impact of Advanced Dual-Echo fMRI Combinations
Kettinger, Ádám; Hill, Christopher; Vidnyánszky, Zoltán; Windischberger, Christian; Nagy, Zoltán
2016-01-01
Multi-echo fMRI data acquisition has been widely investigated and suggested to optimize sensitivity for detecting the BOLD signal. Several methods have also been proposed for the combination of data with different echo times. The aim of the present study was to investigate whether these advanced echo combination methods provide advantages over the simple averaging of echoes when state-of-the-art group-level random-effect analyses are performed. Both resting-state and task-based dual-echo fMRI data were collected from 27 healthy adult individuals (14 male, mean age = 25.75 years) using standard echo-planar acquisition methods at 3T. Both resting-state and task-based data were subjected to a standard image pre-processing pipeline. Subsequently the two echoes were combined as a weighted average, using four different strategies for calculating the weights: (1) simple arithmetic averaging, (2) BOLD sensitivity weighting, (3) temporal-signal-to-noise ratio weighting and (4) temporal BOLD sensitivity weighting. Our results clearly show that the simple averaging of data with the different echoes is sufficient. Advanced echo combination methods may provide advantages on a single-subject level but when considering random-effects group level statistics they provide no benefit regarding sensitivity (i.e., group-level t-values) compared to the simple echo-averaging approach. One possible reason for the lack of clear advantages may be that apart from increasing the average BOLD sensitivity at the single-subject level, the advanced weighted averaging methods also inflate the inter-subject variance. As the echo combination methods provide very similar results, the recommendation is to choose between them depending on the availability of time for collecting additional resting-state data or whether subject-level or group-level analyses are planned. PMID:28018165
McKenna, Jean; Rippon, A. E.
1965-01-01
1. A simple method for the extraction of 17-oxo steroid sulphates of plasma is described; glucosiduronates and orthophosphates are extracted, but to a smaller extent. 2. Four methods of analyses of the extracts are given and are relatively simple. Three of these are specific for steroid sulphates and two measure the sulphate conjugates directly. 3. Values for dehydroepiandrosterone sulphate and androsterone sulphate concentrations of normal and pathological plasmas are given. PMID:14333546
Whole-Range Assessment: A Simple Method for Analysing Allelopathic Dose-Response Data
An, Min; Pratley, J. E.; Haig, T.; Liu, D.L.
2005-01-01
Based on the typical biological responses of an organism to allelochemicals (hormesis), concepts of whole-range assessment and inhibition index were developed for improved analysis of allelopathic data. Examples of their application are presented using data drawn from the literature. The method is concise and comprehensive, and makes data grouping and multiple comparisons simple, logical, and possible. It improves data interpretation, enhances research outcomes, and is a statistically efficient summary of the plant response profiles. PMID:19330165
NASA Technical Reports Server (NTRS)
Newell, J. D.; Keller, R. A.; Baily, N. A.
1974-01-01
A simple method for outlining or contouring any area defined by a change in film density or fluoroscopic screen intensity is described. The entire process, except for the positioning of an electronic window, is accomplished using a small computer having appropriate softwave. The electronic window is operator positioned over the area to be processed. The only requirement is that the window be large enough to encompass the total area to be considered.
A SIMPLE, EFFICIENT SOLUTION OF FLUX-PROFILE RELATIONSHIPS IN THE ATMOSPHERIC SURFACE LAYER
This note describes a simple scheme for analytical estimation of the surface layer similarity functions from state variables. What distinguishes this note from the many previous papers on this topic is that this method is specifically targeted for numerical models where simplici...
A Simple Method for Encouraging Active Participation in Small-Group Discussion Sessions
ERIC Educational Resources Information Center
Lee, Adrian
1977-01-01
A format for a small-group teaching session is described that could be modified for any subject in a medical curriculum. The technique discussed uses subgroups and a simple recording chart that have been successful in teaching microbiology to medical students. (LBH)
Fourier Spectroscopy: A Simple Analysis Technique
ERIC Educational Resources Information Center
Oelfke, William C.
1975-01-01
Presents a simple method of analysis in which the student can integrate, point by point, any interferogram to obtain its Fourier transform. The manual technique requires no special equipment and is based on relationships that most undergraduate physics students can derive from the Fourier integral equations. (Author/MLH)
NASA Astrophysics Data System (ADS)
Sabale, Pramod M.; George, Jerrin Thomas; Srivatsan, Seergazhi G.
2014-08-01
Given the biological and therapeutic significance of telomeres and other G-quadruplex forming sequences in human genome, it is highly desirable to develop simple methods to study these structures, which can also be implemented in screening formats for the discovery of G-quadruplex binders. The majority of telomere detection methods developed so far are laborious and use elaborate assay and instrumental setups, and hence, are not amenable to discovery platforms. Here, we describe the development of a simple homogeneous fluorescence turn-on method, which uses a unique combination of an environment-sensitive fluorescent nucleobase analogue, the superior base pairing property of PNA, and DNA-binding and fluorescence quenching properties of graphene oxide, to detect human telomeric DNA repeats of varying lengths. Our results demonstrate that this method, which does not involve a rigorous assay setup, would provide new opportunities to study G-quadruplex structures.Given the biological and therapeutic significance of telomeres and other G-quadruplex forming sequences in human genome, it is highly desirable to develop simple methods to study these structures, which can also be implemented in screening formats for the discovery of G-quadruplex binders. The majority of telomere detection methods developed so far are laborious and use elaborate assay and instrumental setups, and hence, are not amenable to discovery platforms. Here, we describe the development of a simple homogeneous fluorescence turn-on method, which uses a unique combination of an environment-sensitive fluorescent nucleobase analogue, the superior base pairing property of PNA, and DNA-binding and fluorescence quenching properties of graphene oxide, to detect human telomeric DNA repeats of varying lengths. Our results demonstrate that this method, which does not involve a rigorous assay setup, would provide new opportunities to study G-quadruplex structures. Electronic supplementary information (ESI) available. Figures, tables, experimental procedures and NMR spectra. See DOI: 10.1039/c4nr00878b
A convenient Simple Method for Synthesis of Meta-iodobenzylguanidine (MIBG).
Sheikholislam, Zahra; Soleimani, Zohreh; Moghimi, Abolghasem; Shahhosseini, Soraya
2013-01-01
Radioiodinated meta-iodobenzylguanidine (MIBG) is one of the important radiopharmaceuticals in Nuclear Medicine. [(123/131)I] MIBG is used for imaging of Adrenal medulla, studying heart sympathetic nerves, treatment of pheochromacytoma and neuroblastoma. For clinical application, radioiodinated MIBG is prepared through isotopic exchange method, which includes replacement of radioactive iodine in a nucleophilic substitution reaction with cold iodine ((127)I). The unlabelled MIBG hemisulfate is synthesized by the procedure described by Wieland et al. (1980). The availability of a more practical and cost-effective procedure for MIBG preparation encouraged us to study the MIBG synthesis methods. In this study the preparation of MIBG through different methods were evaluated and a new method, which is one step, simple and cost-effective is introduced. The method has ability to be scaled up for production of unlabelled MIBG.
2012-01-01
Background A single-step blending approach allows genomic prediction using information of genotyped and non-genotyped animals simultaneously. However, the combined relationship matrix in a single-step method may need to be adjusted because marker-based and pedigree-based relationship matrices may not be on the same scale. The same may apply when a GBLUP model includes both genomic breeding values and residual polygenic effects. The objective of this study was to compare single-step blending methods and GBLUP methods with and without adjustment of the genomic relationship matrix for genomic prediction of 16 traits in the Nordic Holstein population. Methods The data consisted of de-regressed proofs (DRP) for 5 214 genotyped and 9 374 non-genotyped bulls. The bulls were divided into a training and a validation population by birth date, October 1, 2001. Five approaches for genomic prediction were used: 1) a simple GBLUP method, 2) a GBLUP method with a polygenic effect, 3) an adjusted GBLUP method with a polygenic effect, 4) a single-step blending method, and 5) an adjusted single-step blending method. In the adjusted GBLUP and single-step methods, the genomic relationship matrix was adjusted for the difference of scale between the genomic and the pedigree relationship matrices. A set of weights on the pedigree relationship matrix (ranging from 0.05 to 0.40) was used to build the combined relationship matrix in the single-step blending method and the GBLUP method with a polygenetic effect. Results Averaged over the 16 traits, reliabilities of genomic breeding values predicted using the GBLUP method with a polygenic effect (relative weight of 0.20) were 0.3% higher than reliabilities from the simple GBLUP method (without a polygenic effect). The adjusted single-step blending and original single-step blending methods (relative weight of 0.20) had average reliabilities that were 2.1% and 1.8% higher than the simple GBLUP method, respectively. In addition, the GBLUP method with a polygenic effect led to less bias of genomic predictions than the simple GBLUP method, and both single-step blending methods yielded less bias of predictions than all GBLUP methods. Conclusions The single-step blending method is an appealing approach for practical genomic prediction in dairy cattle. Genomic prediction from the single-step blending method can be improved by adjusting the scale of the genomic relationship matrix. PMID:22455934
Coherent Anomaly Method Calculation on the Cluster Variation Method. II.
NASA Astrophysics Data System (ADS)
Wada, Koh; Watanabe, Naotosi; Uchida, Tetsuya
The critical exponents of the bond percolation model are calculated in the D(= 2,3,…)-dimensional simple cubic lattice on the basis of Suzuki's coherent anomaly method (CAM) by making use of a series of the pair, the square-cactus and the square approximations of the cluster variation method (CVM) in the s-state Potts model. These simple approximations give reasonable values of critical exponents α, β, γ and ν in comparison with ones estimated by other methods. It is also shown that the results of the pair and the square-cactus approximations can be derived as exact results of the bond percolation model on the Bethe and the square-cactus lattice, respectively, in the presence of ghost field without recourse to the s→1 limit of the s-state Potts model.
High order filtering methods for approximating hyberbolic systems of conservation laws
NASA Technical Reports Server (NTRS)
Lafon, F.; Osher, S.
1990-01-01
In the computation of discontinuous solutions of hyperbolic systems of conservation laws, the recently developed essentially non-oscillatory (ENO) schemes appear to be very useful. However, they are computationally costly compared to simple central difference methods. A filtering method which is developed uses simple central differencing of arbitrarily high order accuracy, except when a novel local test indicates the development of spurious oscillations. At these points, the full ENO apparatus is used, maintaining the high order of accuracy, but removing spurious oscillations. Numerical results indicate the success of the method. High order of accuracy was obtained in regions of smooth flow without spurious oscillations for a wide range of problems and a significant speed up of generally a factor of almost three over the full ENO method.
Sevrain, David; Dubreuil, Matthieu; Dolman, Grace Elizabeth; Zaitoun, Abed; Irving, William; Guha, Indra Neil; Odin, Christophe; Le Grand, Yann
2015-01-01
In this paper we analyze a fibrosis scoring method based on measurement of the fibrillar collagen area from second harmonic generation (SHG) microscopy images of unstained histological slices from human liver biopsies. The study is conducted on a cohort of one hundred chronic hepatitis C patients with intermediate to strong Metavir and Ishak stages of liver fibrosis. We highlight a key parameter of our scoring method to discriminate between high and low fibrosis stages. Moreover, according to the intensity histograms of the SHG images and simple mathematical arguments, we show that our area-based method is equivalent to an intensity-based method, despite saturation of the images. Finally we propose an improvement of our scoring method using very simple image processing tools. PMID:25909005
Sevrain, David; Dubreuil, Matthieu; Dolman, Grace Elizabeth; Zaitoun, Abed; Irving, William; Guha, Indra Neil; Odin, Christophe; Le Grand, Yann
2015-04-01
In this paper we analyze a fibrosis scoring method based on measurement of the fibrillar collagen area from second harmonic generation (SHG) microscopy images of unstained histological slices from human liver biopsies. The study is conducted on a cohort of one hundred chronic hepatitis C patients with intermediate to strong Metavir and Ishak stages of liver fibrosis. We highlight a key parameter of our scoring method to discriminate between high and low fibrosis stages. Moreover, according to the intensity histograms of the SHG images and simple mathematical arguments, we show that our area-based method is equivalent to an intensity-based method, despite saturation of the images. Finally we propose an improvement of our scoring method using very simple image processing tools.
[FQA: A method for floristic quality assessment based on conservatism of plant species].
Cao, Li Juan; He, Ping; Wang, Mi; Xui, Jie; Ren, Ying
2018-04-01
FQA, which uses the conservatism of plant species for particular habitats and the species richness of plant communities, is a rapid method for the assessment of habitat quality. This method is based on species composition of quadrats and coefficients of conservatism for species which assigned by experts. Floristic Quality Index (FQI) that reflects vegetation integrity and degradation of a site can be calculated by a simple formula and be used for space-time comparison of habitat quality. It has been widely used in more than ten countries including the United States and Canada. This paper presented the principle, calculation formulas and application cases of this method, with the aim to provide a simple, repeatable and comparable method to assess habitat quality for ecological managers and researchers.
Sensitive sub-Doppler nonlinear spectroscopy for hyperfine-structure analysis using simple atomizers
NASA Astrophysics Data System (ADS)
Mickadeit, Fritz K.; Kemp, Helen; Schafer, Julia; Tong, William M.
1998-05-01
Laser wave-mixing spectroscopy is presented as a sub-Doppler method that offers not only high spectral resolution, but also excellent detection sensitivity. It offers spectral resolution suitable for hyperfine structure analysis and isotope ratio measurements. In a non-planar backward- scattering four-wave mixing optical configuration, two of the three input beams counter propagate and the Doppler broadening is minimized, and hence, spectral resolution is enhanced. Since the signal is a coherent beam, optical collection is efficient and signal detection is convenient. This simple multi-photon nonlinear laser method offers un usually sensitive detection limits that are suitable for trace-concentration isotope analysis using a few different types of simple analytical atomizers. Reliable measurement of hyperfine structures allows effective determination of isotope ratios for chemical analysis.
NASA Astrophysics Data System (ADS)
Baran, Talat; Yılmaz Baran, Nuray; Menteş, Ayfer
2018-05-01
In this study, we reported production, characterization, and catalytic behavior of two novel heterogeneous palladium(II) and platinum(II) catalysts derived from cellulose biopolymer. In order to eliminate the use of toxic organic or inorganic solvents and to reduce the use of excess energy in the coupling reactions, we have developed a very simple, rapid, and eco-friendly microwave irradiation protocol. The developed microwave-assisted method of Suzuki cross coupling reactions produced excellent reaction yields in the presence of cellulose supported palladium and platinum (II) catalysts. Moreover, the catalysts easily regenerated after simple filtration, and they gave good reusability. This study revealed that the designed catalysts and method provide clean, simple, rapid, and impressive catalytic performance for Suzuki coupling reactions.
NASA Astrophysics Data System (ADS)
Zárate, Francisco; Cornejo, Alejandro; Oñate, Eugenio
2018-07-01
This paper extends to three dimensions (3D), the computational technique developed by the authors in 2D for predicting the onset and evolution of fracture in a finite element mesh in a simple manner based on combining the finite element method and the discrete element method (DEM) approach (Zárate and Oñate in Comput Part Mech 2(3):301-314, 2015). Once a crack is detected at an element edge, discrete elements are generated at the adjacent element vertexes and a simple DEM mechanism is considered in order to follow the evolution of the crack. The combination of the DEM with simple four-noded linear tetrahedron elements correctly captures the onset of fracture and its evolution, as shown in several 3D examples of application.
Design and analysis of simple choice surveys for natural resource management
Fieberg, John; Cornicelli, Louis; Fulton, David C.; Grund, Marrett D.
2010-01-01
We used a simple yet powerful method for judging public support for management actions from randomized surveys. We asked respondents to rank choices (representing management regulations under consideration) according to their preference, and we then used discrete choice models to estimate probability of choosing among options (conditional on the set of options presented to respondents). Because choices may share similar unmodeled characteristics, the multinomial logit model, commonly applied to discrete choice data, may not be appropriate. We introduced the nested logit model, which offers a simple approach for incorporating correlation among choices. This forced choice survey approach provides a useful method of gathering public input; it is relatively easy to apply in practice, and the data are likely to be more informative than asking constituents to rate attractiveness of each option separately.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu, Dong, E-mail: d.qiu@uq.edu.au; Zhang, Mingxing
2014-08-15
A simple and inclusive method is proposed for accurate determination of the habit plane between bicrystals in transmission electron microscope. Whilst this method can be regarded as a variant of surface trace analysis, the major innovation lies in the improved accuracy and efficiency of foil thickness measurement, which involves a simple tilt of the thin foil about a permanent tilting axis of the specimen holder, rather than cumbersome tilt about the surface trace of the habit plane. Experimental study has been done to validate this proposed method in determining the habit plane between lamellar α{sub 2} plates and γ matrixmore » in a Ti–Al–Nb alloy. Both high accuracy (± 1°) and high precision (± 1°) have been achieved by using the new method. The source of the experimental errors as well as the applicability of this method is discussed. Some tips to minimise the experimental errors are also suggested. - Highlights: • An improved algorithm is formulated to measure the foil thickness. • Habit plane can be determined with a single tilt holder based on the new algorithm. • Better accuracy and precision within ± 1° are achievable using the proposed method. • The data for multi-facet determination can be collected simultaneously.« less
Simple method for quick estimation of aquifer hydrogeological parameters
NASA Astrophysics Data System (ADS)
Ma, C.; Li, Y. Y.
2017-08-01
Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.
Farinati, F; Cardin, F; Di Mario, F; Sava, G A; Piccoli, A; Costa, F; Penon, G; Naccarato, R
1987-08-01
The endoscopic diagnosis of chronic atrophic gastritis is often underestimated, and most of the procedures adopted to increase diagnostic accuracy are time consuming and complex. In this study, we evaluated the usefulness of the determination of gastric juice pH by means of litmus paper. Values obtained by this method correlate well with gastric acid secretory capacity as measured by gastric acid analysis (r = -0.64, p less than 0.001) and are not affected by the presence of bile. Gastric juice pH determination increases sensitivity and other diagnostic parameters such as performance index (Youden J test), positive predictive value, and post-test probability difference by 50%. Furthermore, the negative predictive value is very high, the probability of missing a patient with chronic atrophic gastritis with this simple method being 2% for fundic and 15% for antral atrophic change. We conclude that gastric juice pH determination, which substantially increases diagnostic accuracy and is very simple to perform, should be routinely adopted.
Filtration Isolation of Nucleic Acids: A Simple and Rapid DNA Extraction Method.
McFall, Sally M; Neto, Mário F; Reed, Jennifer L; Wagner, Robin L
2016-08-06
FINA, filtration isolation of nucleic acids, is a novel extraction method which utilizes vertical filtration via a separation membrane and absorbent pad to extract cellular DNA from whole blood in less than 2 min. The blood specimen is treated with detergent, mixed briefly and applied by pipet to the separation membrane. The lysate wicks into the blotting pad due to capillary action, capturing the genomic DNA on the surface of the separation membrane. The extracted DNA is retained on the membrane during a simple wash step wherein PCR inhibitors are wicked into the absorbent blotting pad. The membrane containing the entrapped DNA is then added to the PCR reaction without further purification. This simple method does not require laboratory equipment and can be easily implemented with inexpensive laboratory supplies. Here we describe a protocol for highly sensitive detection and quantitation of HIV-1 proviral DNA from 100 µl whole blood as a model for early infant diagnosis of HIV that could readily be adapted to other genetic targets.
NASA Astrophysics Data System (ADS)
Tran, Thien Khanh; Tran, Hoai Nam; Nguyen, Thuy Linh; Leu, Hoang Jyn
2018-04-01
Nowadays, the pollution of water environment has become a significant problem that really requires a long term solution to deal with. In this study, we provide a simple method to create a capable electrode for electrochemical treatment of wastewater or even can be used as a filter by a physical method. Carbon fiber clothes 300×700 mm were chosen to carry on experiments of Polyaniline (PANI) electrodeposition. Generally, PANI was used to be deposited by three electrodes electrochemical system, however, our samples we obtained here are created by a simple two-electrode electrochemical system. Nevertheless, the product fiber cloth is controlled with a thickness of 0.19 mm and the mass density of 0.44g/cm3, the whole process was carried out under simple lab scale condition at Ton Duc Thang University. To clarify the properties of our products, there was some measurement applied, such as SEM for surface monographic investigation, thermal conductivity by DSC, electrical conductivity by CV and material properties by XRD and EDS measurement. In that manner, we believe that there is still more room for this method to improve in the near future and a bright chance to apply to industrial processes.
Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; Shentu, Jianzhong
2014-01-01
A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5 μ m) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012-5.78 ng·mL(-1) for blonanserin and 0.023-11.57 ng·mL(-1) for blonanserin C (r (2) > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers.
Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; ShenTu, Jianzhong
2014-01-01
A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5 μm) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012–5.78 ng·mL−1 for blonanserin and 0.023–11.57 ng·mL−1 for blonanserin C (r 2 > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers. PMID:24678425
Garrett, David J; Flavel, Benjamin S; Baronian, Keith H R; Downard, Alison J
2013-01-01
A simple method for producing patterned forests of multiwalled carbon nanotubes (MWCNTs) is described. An aqueous metal salt solution is spin-coated onto a substrate patterned with photoresist by standard methods. The photoresist is removed by acetone washing leaving the acetone-insoluble catalyst pattern on the substrate. Dense forests of vertically aligned (VA) MWCNTs are grown on the patterned catalyst layers by chemical vapour deposition. The procedures have been demonstrated by growing MWCNT forests on two substrates: silicon and conducting graphitic carbon films. The forests adhere strongly to the substrates and when grown directly on carbon film, offer a simple method of preparing MWCNT electrodes.
Preparation and Optoelectrical Properties of p-CuO/n-Si Heterojunction by a Simple Sol-Gel Method
NASA Astrophysics Data System (ADS)
He, Bo; Xu, Jing; Ning, Huanpo; Zhao, Lei; Xing, Huaizhong; Chang, Chien-Cheng; Qin, Yuming; Zhang, Lei
The Cuprous oxide (CuO) thin film was prepared on texturized Si wafer by a simple sol-gel method to fabricate p-CuO/n-Si heterojunction photoelectric device. The novel sol-gel method is very cheap and convenient. The structural, optical and electrical properties of the CuO film were studied by X-ray diffraction (XRD), Scanning Electron Microscope (SEM), X-ray photoelectron spectroscopy (XPS), UV-Vis spectrophotometer and Hall effect measurement. A good nonlinear rectifying behavior is obtained for the p-CuO/n-Si heterojunction. Under reverse bias, good photoelectric behavior is obtained.
Song, Shi-Lin
2013-04-01
To seek a precise and simple method for localization of acupoint in anatomical experiment teaching. Medical bone needles were inserted into acupoints. Then, self-mode copper probe needles were thrust along the center of the bone needles to open the inner structures of acuppoints. And probe needles were replaced by colored plastic tubes. Finally, bone needles were withdrawn so as to fix the plastic tubes into the acupoints to facilitate the later cutting. This method for acupoint anatomic positioning is of low cost with accurate positioning and simple manipulation, which has advantages in strong experimental and innovative values.
Okada, Morihiro; Miller, Thomas C; Roediger, Julia; Shi, Yun-Bo; Schech, Joseph Mat
2017-09-01
Various animal models are indispensible in biomedical research. Increasing awareness and regulations have prompted the adaptation of more humane approaches in the use of laboratory animals. With the development of easier and faster methodologies to generate genetically altered animals, convenient and humane methods to genotype these animals are important for research involving such animals. Here, we report skin swabbing as a simple and noninvasive method for extracting genomic DNA from mice and frogs for genotyping. We show that this method is highly reliable and suitable for both immature and adult animals. Our approach allows a simpler and more humane approach for genotyping vertebrate animals.
Smirr, Jean-Loup; Guilbaud, Sylvain; Ghalbouni, Joe; Frey, Robert; Diamanti, Eleni; Alléaume, Romain; Zaquine, Isabelle
2011-01-17
Fast characterization of pulsed spontaneous parametric down conversion (SPDC) sources is important for applications in quantum information processing and communications. We propose a simple method to perform this task, which only requires measuring the counts on the two output channels and the coincidences between them, as well as modeling the filter used to reduce the source bandwidth. The proposed method is experimentally tested and used for a complete evaluation of SPDC sources (pair emission probability, total losses, and fidelity) of various bandwidths. This method can find applications in the setting up of SPDC sources and in the continuous verification of the quality of quantum communication links.
Facile generation of cell microarrays using vacuum degassing and coverslip sweeping.
Wang, Min S; Luo, Zhen; Cherukuri, Sundar; Nitin, Nitin
2014-07-15
A simple method to generate cell microarrays with high-percentage well occupancy and well-defined cell confinement is presented. This method uses a synergistic combination of vacuum degassing and coverslip sweeping. The vacuum degassing step dislodges air bubbles from the microwells, which in turn enables the cells to enter the microwells, while the physical sweeping step using a glass coverslip removes the excess cells outside the microwells. This low-cost preparation method provides a simple solution to generating cell microarrays that can be performed in basic research laboratories and point-of-care settings for routine cell-based screening assays. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lacassagne, Tom; Simoëns, Serge; El Hajem, Mahmoud; Champagne, Jean-Yves
2018-01-01
Inhibited planar laser-induced fluorescence (I-PLIF) techniques are widely used for heat and mass transfer studies in fluid mechanics. They allow the visualization of instantaneous two-dimensional field of a passive or reactive scalar, providing that this scalar acts as an inhibitor to the fluorescence of a specific molecule, and that this molecule is homogeneously mixed in the fluid at a known concentration. Local scalar values are deduced from fluorescence recordings thanks to preliminary calibration procedure. When confronted with non-optically thin systems, however, the knowledge of the excitation intensity distribution in the region of interest is also required, and this information is most of the time hard to obtain. To overcome that problem, two-color ratiometric PLIF techniques ( {I}^ {r}-PLIF) have been developed. In these methods, the ratio of two different fluorescence wavelengths triggered by the same excitation is used as an indicator of the scalar value. Such techniques have been used for temperature measurements in several studies but never, to the author's knowledge, for pH tracking and acid-base mixing, despite the frequent use of the one-color version in mass transfer studies. In the present work, a ratiometric pH-sensitive-inhibited PLIF technique ( {I}_ {pH}^ {r}-PLIF) using fluorescein sodium as a single dye and applicable to complex geometries and flows is developed. Theoretical considerations show that the ratio of the two-color fluorescence intensities should only depend on the dye's spectral quantum yield, itself pH-dependent. A detailed spectrofluorimetric study of fluorescein reveals that this ratio strictly increases with the pH for two well-chosen spectral bands (fluorescence colors). A similar trend is found when using sCmos cameras equipped with optical filters to record fluorescence signals. The method is then experimented on a test flow, a turbulent acidic jet injected in an initially pH-neutral volume of fluid. The results obtained using the ratiometric version are consistent with single-color technique measurements, but excitation intensity heterogeneity is more efficiently accounted for, with a much smaller time needed for data treatment and without requiring the knowledge of laser paths across the fluid. This new technique is also able to reduce the impact of some unwanted experimental features such as time-varying excitation intensity or reflections at interfaces. It can be of great interest for further applications to multiphase mass transfer studies.
A Simple Laser Microphone for Classroom Demonstration
ERIC Educational Resources Information Center
Moses, James M.; Trout, K. P.
2006-01-01
Communication through the modulation of electromagnetic radiation has become a foundational technique in modern technology. In this paper we discuss a modern day method of eavesdropping based upon the modulation of laser light reflected from a window pane. A simple and affordable classroom demonstration of a "laser microphone" is…
ERIC Educational Resources Information Center
Touati, Faiza; McGuigan, Kevin G.; Cassidy, John
2007-01-01
A simple method of casting with a Ti[O[subscript]2]/polyvinylchloride (PVC) composite layer was used to describe the behavior of coated electrodes. The system demonstrated that even with low energy light sources, an enhancement of the oxidation efficiency is possible.
Simple and effective method to lock buoy position to ocean currents
NASA Technical Reports Server (NTRS)
Vachon, W. A.; Dahlen, J. M.
1975-01-01
Window-shade drogue, used with drifting buoys to keep them moving with current at speed as close to that of current as possible, has drag coefficient of 1.93 compared to maximum of 1.52 for previous drogues. It is remarkably simple to construct, use, and store.
Setaria viridis floral-dip: A simple and rapid Agrobacterium-medicated transformation method
USDA-ARS?s Scientific Manuscript database
Setaria viridis was recently described as a new monocotyledonous model species for C4 photosynthesis research and genetic transformation. It has biological attributes (rapid life cycle, small genome, diploid, short stature and simple growth requirements) that make it suitable for use as a model plan...
Simple & Rapid Generation of Complex DNA Profiles for the Undergraduate Laboratory
ERIC Educational Resources Information Center
Kass, David H.
2007-01-01
Deoxyribonucleic acid (DNA) profiles can be generated by a variety of techniques incorporating different types of DNA markers. Simple methods are commonly utilized in the undergraduate laboratory, but with certain drawbacks. In this article, the author presents an advancement of the "Alu" dimorphism technique involving two tetraplex polymerase…
An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.
ERIC Educational Resources Information Center
Moehs, Peter J.; Levine, Samuel
1982-01-01
A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…
Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.
Jürgens, Ignasi; Rey, Amanda
2015-01-01
We describe a simple surgical technique to manage pupillary capture after previous transscleral fixation of an intraocular lens. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Simple Analysis of Historical Lime Mortars
ERIC Educational Resources Information Center
Pires, Joa~o
2015-01-01
A laboratory experiment is described in which a simple characterization of a historical lime mortar is made by the determination of its approximate composition by a gravimetric method. Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD) are also used for the qualitative characterization of the lime mortar components. These…
High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory
ERIC Educational Resources Information Center
Frey, Douglas D.; Guo, Hui; Karnik, Nikhila
2013-01-01
This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…
Amplitude Frequency Response Measurement: A Simple Technique
ERIC Educational Resources Information Center
Satish, L.; Vora, S. C.
2010-01-01
A simple method is described to combine a modern function generator and a digital oscilloscope to configure a setup that can directly measure the amplitude frequency response of a system. This is achieved by synchronously triggering both instruments, with the function generator operated in the "Linear-Sweep" frequency mode, while the oscilloscope…
Building Simple Hidden Markov Models. Classroom Notes
ERIC Educational Resources Information Center
Ching, Wai-Ki; Ng, Michael K.
2004-01-01
Hidden Markov models (HMMs) are widely used in bioinformatics, speech recognition and many other areas. This note presents HMMs via the framework of classical Markov chain models. A simple example is given to illustrate the model. An estimation method for the transition probabilities of the hidden states is also discussed.
Tour of a Simple Trigonometry Problem
ERIC Educational Resources Information Center
Poon, Kin-Keung
2012-01-01
This article focuses on a simple trigonometric problem that generates a strange phenomenon when different methods are applied to tackling it. A series of problem-solving activities are discussed, so that students can be alerted that the precision of diagrams is important when solving geometric problems. In addition, the problem-solving plan was…
ERIC Educational Resources Information Center
Britton, L. N.; And Others
1988-01-01
Considers the applicability of the simple emersion/weight-gain method for predicting diffusion coefficients, solubilities, and permeation rates of chemicals in polymers that do not undergo physical and chemical deterioration. Presents the theoretical background, procedures and typical results related to this activity. (CW)
A RAPID AND SIMPLE PHOSPHOLIPASE A ASSAY,
A simple and rapid method for the assay of phospholipase A was developed. As a substrate fresh egg yolk is used which is hydrolyzed by snake venom...phospholipase A at a 10-20 x faster rate than pure lecithin . The released fatty acids, after extraction with appropriate solvents are titrated
Variations on a Simple Dice Game
ERIC Educational Resources Information Center
Heafner, Joe
2018-01-01
I begin my introductory astronomy course with a unit on critical thinking that focuses on, among other things, the differences between the "scientific method" as frequently presented in textbooks and actual scientific practice. One particular classroom activity uses a simple dice game to simulate observation of a natural phenomenon and…
Safety in the Chemical Laboratory: Laboratory Air Quality: Part I. A Concentration Model.
ERIC Educational Resources Information Center
Butcher, Samuel S.; And Others
1985-01-01
Offers a simple model for estimating vapor concentrations in instructional laboratories. Three methods are described for measuring ventilation rates, and the results of measurements in six laboratories are presented. The model should provide a simple screening tool for evaluating worst-case personal exposures. (JN)
Composite annotations: requirements for mapping multiscale data and models to biomedical ontologies
Cook, Daniel L.; Mejino, Jose L. V.; Neal, Maxwell L.; Gennari, John H.
2009-01-01
Current methods for annotating biomedical data resources rely on simple mappings between data elements and the contents of a variety of biomedical ontologies and controlled vocabularies. Here we point out that such simple mappings are inadequate for large-scale multiscale, multidomain integrative “virtual human” projects. For such integrative challenges, we describe a “composite annotation” schema that is simple yet sufficiently extensible for mapping the biomedical content of a variety of data sources and biosimulation models to available biomedical ontologies. PMID:19964601
ERIC Educational Resources Information Center
Geddes, L. A.
1980-01-01
Presents audiovisual methods to aid instruction in measuring blood pressure by indirect methods, so that a large screen display for cuff pressure is produced and high intensity Korotkoff sounds are amplified. (CS)
NASA Technical Reports Server (NTRS)
Jefferies, S. M.; Duvall, T. L., Jr.
1991-01-01
A measurement of the intensity distribution in an image of the solar disk will be corrupted by a spatial redistribution of the light that is caused by the earth's atmosphere and the observing instrument. A simple correction method is introduced here that is applicable for solar p-mode intensity observations obtained over a period of time in which there is a significant change in the scattering component of the point spread function. The method circumvents the problems incurred with an accurate determination of the spatial point spread function and its subsequent deconvolution from the observations. The method only corrects the spherical harmonic coefficients that represent the spatial frequencies present in the image and does not correct the image itself.
Orr, G; Roth, M
2012-08-01
A low-voltage (mV) electronically triggered spot welding system for fabricating fine thermocouples and thin sheets used in high-temperature characterization of materials' properties is suggested. The system is based on the capacitance discharge method with a timed trigger for obtaining reliable and consistent welds. In contrast to existing techniques based on employing high voltage DC supplies for charging the capacitor or supplies with positive and negative rails, this method uses a simple, standard dual power supply available at most of the physical laboratories or can be acquired at a low cost. In addition, an efficient and simple method of fabricating non-sticking electrodes that do not contaminate the weld area is suggested and implemented.
A simple and efficient method for predicting protein-protein interaction sites.
Higa, R H; Tozzi, C L
2008-09-23
Computational methods for predicting protein-protein interaction sites based on structural data are characterized by an accuracy between 70 and 80%. Some experimental studies indicate that only a fraction of the residues, forming clusters in the center of the interaction site, are energetically important for binding. In addition, the analysis of amino acid composition has shown that residues located in the center of the interaction site can be better discriminated from the residues in other parts of the protein surface. In the present study, we implement a simple method to predict interaction site residues exploiting this fact and show that it achieves a very competitive performance compared to other methods using the same dataset and criteria for performance evaluation (success rate of 82.1%).
Tanahashi, Mitsuru
2010-01-01
Many attempts have been made to fabricate various types of inorganic nanoparticle-filled polymers (filler/polymer nanocomposites) by a mechanical or chemical approach. However, these approaches require modification of the nanofiller surfaces and/or complicated polymerization reactions, making them unsuitable for industrial-scale production of the nanocomposites. The author and coworkers have proposed a simple melt-compounding method for the fabrication of silica/polymer nanocomposites, wherein silica nanoparticles without surface modification were dispersed through the breakdown of loose agglomerates of colloidal nano-silica spheres in a kneaded polymer melt. This review aims to discuss experimental techniques of the proposed method and its advantages over other developed methods.
Repairing Damaged Power-Cable Insulation
NASA Technical Reports Server (NTRS)
Baker, G. E.
1984-01-01
Simple method saves time, money, and material. In new method cable remains in place while new insulation is applied to damaged portion. Method results in new terminations with safety factor equal to that of any portion of cable.
Li, Zhengqiang; Li, Kaitao; Li, Donghui; Yang, Jiuchun; Xu, Hua; Goloub, Philippe; Victori, Stephane
2016-09-20
The Cimel new technologies allow both daytime and nighttime aerosol optical depth (AOD) measurements. Although the daytime AOD calibration protocols are well established, accurate and simple nighttime calibration is still a challenging task. Standard lunar-Langley and intercomparison calibration methods both require specific conditions in terms of atmospheric stability and site condition. Additionally, the lunar irradiance model also has some known limits on its uncertainty. This paper presents a simple calibration method that transfers the direct-Sun calibration constant, V0,Sun, to the lunar irradiance calibration coefficient, CMoon. Our approach is a pure calculation method, independent of site limits, e.g., Moon phase. The method is also not affected by the lunar irradiance model limitations, which is the largest error source of traditional calibration methods. Besides, this new transfer calibration approach is easy to use in the field since CMoon can be obtained directly once V0,Sun is known. Error analysis suggests that the average uncertainty of CMoon over the 440-1640 nm bands obtained with the transfer method is 2.4%-2.8%, depending on the V0,Sun approach (Langley or intercomparison), which is comparable with that of lunar-Langley approach, theoretically. In this paper, the Sun-Moon transfer and the Langley methods are compared based on site measurements in Beijing, and the day-night measurement continuity and performance are analyzed.
Seismic methods are the most commonly conducted geophysical surveys for engineering investigations. Seismic refraction provides engineers and geologists with the most basic of geologic data via simple procedures with common equipment.
The Voronoi volume and molecular representation of molar volume: equilibrium simple fluids.
Hunjan, Jagtar Singh; Eu, Byung Chan
2010-04-07
The Voronoi volume of simple fluids was previously made use of in connection with volume transport phenomena in nonequilibrium simple fluids. To investigate volume transport phenomena, it is important to develop a method to compute the Voronoi volume of fluids in nonequilibrium. In this work, as a first step to this goal, we investigate the equilibrium limit of the nonequilibrium Voronoi volume together with its attendant related molar (molal) and specific volumes. It is proved that the equilibrium Voronoi volume is equivalent to the molar (molal) volume. The latter, in turn, is proved equivalent to the specific volume. This chain of equivalences provides an alternative procedure of computing the equilibrium Voronoi volume from the molar volume/specific volume. We also show approximate methods of computing the Voronoi and molar volumes from the information on the pair correlation function. These methods may be employed for their quick estimation, but also provide some aspects of the fluid structure and its relation to the Voronoi volume. The Voronoi volume obtained from computer simulations is fitted to a function of temperature and pressure in the region above the triple point but below the critical point. Since the fitting function is given in terms of reduced variables for the Lennard-Jones (LJ) model and the kindred volumes (i.e., specific and molar volumes) are in essence equivalent to the equation of state, the formula obtained is a reduced equation state for simple fluids obeying the LJ model potential in the range of temperature and pressure examined and hence can be used for other simple fluids.
Pickl, Karin E; Adamek, Viktor; Gorges, Roland; Sinner, Frank M
2011-07-15
Due to increased regulatory requirements, the interaction of active pharmaceutical ingredients with various surfaces and solutions during production and storage is gaining interest in the pharmaceutical research field, in particular with respect to development of new formulations, new packaging material and the evaluation of cleaning processes. Experimental adsorption/absorption studies as well as the study of cleaning processes require sophisticated analytical methods with high sensitivity for the drug of interest. In the case of 2,6-diisopropylphenol - a small lipophilic drug which is typically formulated as lipid emulsion for intravenous injection - a highly sensitive method in the concentration range of μg/l suitable to be applied to a variety of different sample matrices including lipid emulsions is needed. We hereby present a headspace-solid phase microextraction (HS-SPME) approach as a simple cleanup procedure for sensitive 2,6-diisopropylphenol quantification from diverse matrices choosing a lipid emulsion as the most challenging matrix with regard to complexity. By combining the simple and straight forward HS-SPME sample pretreatment with an optimized GC-MS quantification method a robust and sensitive method for 2,6-diisopropylphenol was developed. This method shows excellent sensitivity in the low μg/l concentration range (5-200μg/l), good accuracy (94.8-98.8%) and precision (intraday-precision 0.1-9.2%, inter-day precision 2.0-7.7%). The method can be easily adapted to other, less complex, matrices such as water or swab extracts. Hence, the presented method holds the potential to serve as a single and simple analytical procedure for 2,6-diisopropylphenol analysis in various types of samples such as required in, e.g. adsorption/absorption studies which typically deal with a variety of different surfaces (steel, plastic, glass, etc.) and solutions/matrices including lipid emulsions. Copyright © 2011 Elsevier B.V. All rights reserved.
40 CFR 35.6565 - Procurement methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Procurement methods. 35.6565 Section 35... Actions Procurement Requirements Under A Cooperative Agreement § 35.6565 Procurement methods. The... purchase procedures are those relatively simple and informal procurement methods for securing services...
40 CFR 35.6565 - Procurement methods.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Procurement methods. 35.6565 Section 35... Actions Procurement Requirements Under A Cooperative Agreement § 35.6565 Procurement methods. The... purchase procedures are those relatively simple and informal procurement methods for securing services...
40 CFR 35.6565 - Procurement methods.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Procurement methods. 35.6565 Section 35... Actions Procurement Requirements Under A Cooperative Agreement § 35.6565 Procurement methods. The... purchase procedures are those relatively simple and informal procurement methods for securing services...
40 CFR 35.6565 - Procurement methods.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Procurement methods. 35.6565 Section 35... Actions Procurement Requirements Under A Cooperative Agreement § 35.6565 Procurement methods. The... purchase procedures are those relatively simple and informal procurement methods for securing services...
40 CFR 35.6565 - Procurement methods.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Procurement methods. 35.6565 Section 35... Actions Procurement Requirements Under A Cooperative Agreement § 35.6565 Procurement methods. The... purchase procedures are those relatively simple and informal procurement methods for securing services...
Diabetes Diet: Create Your Healthy-Eating Plan
... methods works for you: The plate method. The American Diabetes Association offers a simple seven-step method of meal ... complications. Diabetes meal plans and a healthy diet. American Diabetes Association. http://www.diabetes.org/food-and-fitness/food/ ...
Seismic methods are the most commonly conducted geophysical surveys for engineering investigations. Seismic refraction provides engineers and geologists with the most basic of geologic data via simple procedures with common equipment.
An Effective Electrical Resonance-Based Method to Detect Delamination in Thermal Barrier Coating
NASA Astrophysics Data System (ADS)
Kim, Jong Min; Park, Jae-Ha; Lee, Ho Girl; Kim, Hak-Joon; Song, Sung-Jin; Seok, Chang-Sung; Lee, Young-Ze
2017-12-01
This research proposes a simple yet highly sensitive method based on electrical resonance of an eddy-current probe to detect delamination of thermal barrier coating (TBC). This method can directly measure the mechanical characteristics of TBC compared to conventional ultrasonic testing and infrared thermography methods. The electrical resonance-based method can detect the delamination of TBC from the metallic bond coat by shifting the electrical impedance of eddy current testing (ECT) probe coupling with degraded TBC, and, due to this shift, the resonant frequencies near the peak impedance of ECT probe revealed high sensitivity to the delamination. In order to verify the performance of the proposed method, a simple experiment is performed with degraded TBC specimens by thermal cyclic exposure. Consequently, the delamination with growth of thermally grown oxide in a TBC system is experimentally identified. Additionally, the results are in good agreement with the results obtained from ultrasonic C-scanning.
An Effective Electrical Resonance-Based Method to Detect Delamination in Thermal Barrier Coating
NASA Astrophysics Data System (ADS)
Kim, Jong Min; Park, Jae-Ha; Lee, Ho Girl; Kim, Hak-Joon; Song, Sung-Jin; Seok, Chang-Sung; Lee, Young-Ze
2018-02-01
This research proposes a simple yet highly sensitive method based on electrical resonance of an eddy-current probe to detect delamination of thermal barrier coating (TBC). This method can directly measure the mechanical characteristics of TBC compared to conventional ultrasonic testing and infrared thermography methods. The electrical resonance-based method can detect the delamination of TBC from the metallic bond coat by shifting the electrical impedance of eddy current testing (ECT) probe coupling with degraded TBC, and, due to this shift, the resonant frequencies near the peak impedance of ECT probe revealed high sensitivity to the delamination. In order to verify the performance of the proposed method, a simple experiment is performed with degraded TBC specimens by thermal cyclic exposure. Consequently, the delamination with growth of thermally grown oxide in a TBC system is experimentally identified. Additionally, the results are in good agreement with the results obtained from ultrasonic C-scanning.
Microbial reduction of graphene oxide by Escherichia coli: a green chemistry approach.
Gurunathan, Sangiliyandi; Han, Jae Woong; Eppakayala, Vasuki; Kim, Jin-Hoi
2013-02-01
Graphene and graphene related materials are an important area of research in recent years due to their unique properties. The extensive industrial application of graphene and related compounds has led researchers to devise novel and simple methods for the synthesis of high quality graphene. In this paper, we developed an environment friendly, cost effective, simple method and green approaches for the reduction of graphene oxide (GO) using Escherichia coli biomass. In biological method, we can avoid use of toxic and environmentally harmful reducing agents commonly used in the chemical reduction of GO to obtain graphene. The biomass of E. coli reduces exfoliated GO to graphene at 37°C in an aqueous medium. The E. coli reduced graphene oxide (ERGO) was characterized with UV-visible absorption spectroscopy, particle analyzer, high resolution X-ray diffractometer, scanning electron microscopy and Raman spectroscopy. Besides the reduction potential, the biomass could also play an important role as stabilizing agent, in which synthesized graphene exhibited good stability in water. This method can open up the new avenue for preparing graphene in cost effective and large scale production. Our findings suggest that GO can be reduced by simple eco-friendly method by using E. coli biomass to produce water dispersible graphene. Copyright © 2012 Elsevier B.V. All rights reserved.
BASIC: A Simple and Accurate Modular DNA Assembly Method.
Storch, Marko; Casini, Arturo; Mackrow, Ben; Ellis, Tom; Baldwin, Geoff S
2017-01-01
Biopart Assembly Standard for Idempotent Cloning (BASIC) is a simple, accurate, and robust DNA assembly method. The method is based on linker-mediated DNA assembly and provides highly accurate DNA assembly with 99 % correct assemblies for four parts and 90 % correct assemblies for seven parts [1]. The BASIC standard defines a single entry vector for all parts flanked by the same prefix and suffix sequences and its idempotent nature means that the assembled construct is returned in the same format. Once a part has been adapted into the BASIC format it can be placed at any position within a BASIC assembly without the need for reformatting. This allows laboratories to grow comprehensive and universal part libraries and to share them efficiently. The modularity within the BASIC framework is further extended by the possibility of encoding ribosomal binding sites (RBS) and peptide linker sequences directly on the linkers used for assembly. This makes BASIC a highly versatile library construction method for combinatorial part assembly including the construction of promoter, RBS, gene variant, and protein-tag libraries. In comparison with other DNA assembly standards and methods, BASIC offers a simple robust protocol; it relies on a single entry vector, provides for easy hierarchical assembly, and is highly accurate for up to seven parts per assembly round [2].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Figueroa, C.; Brizuela, H.; Heluani, S. P.
2014-05-21
The backscattering coefficient is a magnitude whose measurement is fundamental for the characterization of materials with techniques that make use of particle beams and particularly when performing microanalysis. In this work, we report the results of an analytic method to calculate the backscattering and absorption coefficients of electrons in similar conditions to those of electron probe microanalysis. Starting on a five level states ladder model in 3D, we deduced a set of integro-differential coupled equations of the coefficients with a method know as invariant embedding. By means of a procedure proposed by authors, called method of convergence, two types ofmore » approximate solutions for the set of equations, namely complete and simple solutions, can be obtained. Although the simple solutions were initially proposed as auxiliary forms to solve higher rank equations, they turned out to be also useful for the estimation of the aforementioned coefficients. In previous reports, we have presented results obtained with the complete solutions. In this paper, we present results obtained with the simple solutions of the coefficients, which exhibit a good degree of fit with the experimental data. Both the model and the calculation method presented here can be generalized to other techniques that make use of different sorts of particle beams.« less
Armour, John A. L.; Palla, Raquel; Zeeuwen, Patrick L. J. M.; den Heijer, Martin; Schalkwijk, Joost; Hollox, Edward J.
2007-01-01
Recent work has demonstrated an unexpected prevalence of copy number variation in the human genome, and has highlighted the part this variation may play in predisposition to common phenotypes. Some important genes vary in number over a high range (e.g. DEFB4, which commonly varies between two and seven copies), and have posed formidable technical challenges for accurate copy number typing, so that there are no simple, cheap, high-throughput approaches suitable for large-scale screening. We have developed a simple comparative PCR method based on dispersed repeat sequences, using a single pair of precisely designed primers to amplify products simultaneously from both test and reference loci, which are subsequently distinguished and quantified via internal sequence differences. We have validated the method for the measurement of copy number at DEFB4 by comparison of results from >800 DNA samples with copy number measurements by MAPH/REDVR, MLPA and array-CGH. The new Paralogue Ratio Test (PRT) method can require as little as 10 ng genomic DNA, appears to be comparable in accuracy to the other methods, and for the first time provides a rapid, simple and inexpensive method for copy number analysis, suitable for application to typing thousands of samples in large case-control association studies. PMID:17175532
Agarwal, Shashank; Liu, Feifan; Yu, Hong
2011-10-03
Protein-protein interaction (PPI) is an important biomedical phenomenon. Automatically detecting PPI-relevant articles and identifying methods that are used to study PPI are important text mining tasks. In this study, we have explored domain independent features to develop two open source machine learning frameworks. One performs binary classification to determine whether the given article is PPI relevant or not, named "Simple Classifier", and the other one maps the PPI relevant articles with corresponding interaction method nodes in a standardized PSI-MI (Proteomics Standards Initiative-Molecular Interactions) ontology, named "OntoNorm". We evaluated our system in the context of BioCreative challenge competition using the standardized data set. Our systems are amongst the top systems reported by the organizers, attaining 60.8% F1-score for identifying relevant documents, and 52.3% F1-score for mapping articles to interaction method ontology. Our results show that domain-independent machine learning frameworks can perform competitively well at the tasks of detecting PPI relevant articles and identifying the methods that were used to study the interaction in such articles. Simple Classifier is available at http://sourceforge.net/p/simpleclassify/home/ and OntoNorm at http://sourceforge.net/p/ontonorm/home/.
A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.
Robitaille, Line; Hoffer, L John
2016-04-21
In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.
Real-time fluorescence loop mediated isothermal amplification for the diagnosis of malaria.
Lucchi, Naomi W; Demas, Allison; Narayanan, Jothikumar; Sumari, Deborah; Kabanywanyi, Abdunoor; Kachur, S Patrick; Barnwell, John W; Udhayakumar, Venkatachalam
2010-10-29
Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.
Fokker-Planck Equations of Stochastic Acceleration: A Study of Numerical Methods
NASA Astrophysics Data System (ADS)
Park, Brian T.; Petrosian, Vahe
1996-03-01
Stochastic wave-particle acceleration may be responsible for producing suprathermal particles in many astrophysical situations. The process can be described as a diffusion process through the Fokker-Planck equation. If the acceleration region is homogeneous and the scattering mean free path is much smaller than both the energy change mean free path and the size of the acceleration region, then the Fokker-Planck equation reduces to a simple form involving only the time and energy variables. in an earlier paper (Park & Petrosian 1995, hereafter Paper 1), we studied the analytic properties of the Fokker-Planck equation and found analytic solutions for some simple cases. In this paper, we study the numerical methods which must be used to solve more general forms of the equation. Two classes of numerical methods are finite difference methods and Monte Carlo simulations. We examine six finite difference methods, three fully implicit and three semi-implicit, and a stochastic simulation method which uses the exact correspondence between the Fokker-Planck equation and the it5 stochastic differential equation. As discussed in Paper I, Fokker-Planck equations derived under the above approximations are singular, causing problems with boundary conditions and numerical overflow and underflow. We evaluate each method using three sample equations to test its stability, accuracy, efficiency, and robustness for both time-dependent and steady state solutions. We conclude that the most robust finite difference method is the fully implicit Chang-Cooper method, with minor extensions to account for the escape and injection terms. Other methods suffer from stability and accuracy problems when dealing with some Fokker-Planck equations. The stochastic simulation method, although simple to implement, is susceptible to Poisson noise when insufficient test particles are used and is computationally very expensive compared to the finite difference method.
Saleh, Tawfik A; Abulkibash, A M; Ibrahim, Atta E
2012-04-01
A simple and fast-automated method was developed and validated for the assay of promethazine hydrochloride in pharmaceutical formulations, based on the oxidation of promethazine by cerium in an acidic medium. A portable system, consisting of a programmable syringe pump connected to a potentiometer, was constructed. The developed change in potential during promethazine oxidation was monitored. The related optimum working conditions, such as supporting electrolyte concentration, cerium(IV) concentration and flow rate were optimized. The proposed method was successfully applied to pharmaceutical samples as well as synthetic ones. The obtained results were realized by the official British pharmacopoeia (BP) method and comparable results were obtained. The obtained t-value indicates no significant differences between the results of the proposed and BP methods, with the advantages of the proposed method being simple, sensitive and cost effective.
NASA Astrophysics Data System (ADS)
Wada, Koh; Watanabe, Naotosi; Uchida, Tetsuya
1991-10-01
The critical exponents of the bond percolation model are calculated in the D(=2, 3, \\cdots)-dimensional simple cubic lattice on the basis of Suzuki’s coherent anomaly method (CAM) by making use of a series of the pair, the square-cactus and the square approximations of the cluster variation method (CVM) in the s-state Potts model. These simple approximations give reasonable values of critical exponents α, β, γ and ν in comparison with ones estimated by other methods. It is also shown that the results of the pair and the square-cactus approximations can be derived as exact results of the bond percolation model on the Bethe and the square-cactus lattice, respectively, in the presence of ghost field without recourse to the s→1 limit of the s-state Potts model.
Fiorentino, Ilaria; Gualtieri, Roberto; Barbato, Vincenza; Mollo, Valentina; Braun, Sabrina; Angrisani, Alberto; Turano, Mimmo; Furia, Maria; Netti, Paolo A; Guarnieri, Daniela; Fusco, Sabato; Talevi, Riccardo
2015-01-15
Nanoparticle (NPs) delivery systems in vivo promises to overcome many obstacles associated with the administration of drugs, vaccines, plasmid DNA and RNA materials, making the study of their cellular uptake a central issue in nanomedicine. The uptake of NPs may be influenced by the cell culture stage and the NPs physical-chemical properties. So far, controversial data on NPs uptake have been derived owing to the heterogeneity of NPs and the general use of immortalized cancer cell lines that often behave differently from each other and from primary mammalian cell cultures. Main aims of the present study were to investigate the uptake, endocytosis pathways, intracellular fate and release of well standardized model particles, i.e. fluorescent 44 nm polystyrene NPs (PS-NPs), on two primary mammalian cell cultures, i.e. bovine oviductal epithelial cells (BOEC) and human colon fibroblasts (HCF) by confocal microscopy and spectrofluorimetric analysis. Different drugs and conditions that inhibit specific internalization routes were used to understand the mechanisms that mediate PS-NP uptake. Our data showed that PS-NPs are rapidly internalized by both cell types 1) with similar saturation kinetics; 2) through ATP-independent processes, and 3) quickly released in the culture medium. Our results suggest that PS-NPs are able to rapidly cross the cell membrane through passive translocation during both uptake and release, and emphasize the need to carefully design NPs for drug delivery, to ensure their selective uptake and to optimize their retainment in the targeted cells. Copyright © 2014 Elsevier Inc. All rights reserved.
Vokřál, Ivan; Jirásko, Robert; Stuchlíková, Lucie; Bártíková, Hana; Szotáková, Barbora; Lamka, Jiří; Várady, Marián; Skálová, Lenka
2013-09-23
The increased activity of drug-metabolizing enzymes can protect helminths against the toxic effect of anthelmintics. The aim of this study was to compare the metabolism of the anthelmintic drug albendazole (ABZ) and the activities of selected biotransformation and antioxidant enzymes in three different strains of Haemonchus contortus: the ISE strain (susceptible to common anthelmintics), the BR strain (resistant to benzimidazole anthelmintics) and the WR strain (multi-resistant). H. contortus adults were collected from the abomasum of experimentally infected lambs. In vitro (subcellular fractions of H. contortus homogenate) as well as ex vivo (living nematodes cultivated in flasks with medium) experiments were performed. HPLC with spectrofluorimetric and mass-spectrometric detection was used in the analysis of ABZ metabolites. The in vitro activities of oxidation/antioxidation and conjugation enzymes toward model substrates were also assayed. The in vitro data showed significant differences between the susceptible (ISE) and resistant (BR, WR) strains regarding the activities of peroxidases, catalase and UDP-glucosyltransferases. S-oxidation of ABZ was significantly lower in BR than in the ISE strain. Ex vivo, four ABZ metabolites were identified: ABZ sulphoxide and three ABZ glucosides. In the resistant strains BR and WR, the ex vivo formation of all ABZ glucosides was significantly higher than in the susceptible ISE strain. The altered activities of certain detoxifying enzymes might partly protect the parasites against the toxic effect of the drugs as well as contribute to drug-resistance in these parasites. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Balraj, C.; Ganesh, K.; Elango, K. P.
2011-07-01
Spectroscopic and spectrofluorimetric techniques have been employed to investigate the structure of the charge transfer (CT) complexes of Trimethoprim (TMP) and Cimitidine (CTD) drugs with 2,3,5,6-tetrachloro-1,4-benzoquinone ( p-chloranil, p-CHL). The stoichiometry of the complexes was found to be 1:2 for TMP- p-CHL system and 1:1 for CTD- p-CHL system. The thermodynamic results indicated that the formation of molecular complex between the donors and the acceptor is spontaneous and endothermic. The results of electronic spectral studies indicated that the formation constant for CTD- p-CHL system is found to be higher than that for TMP- p-CHL system. The observation is well supported by the results of fluorescence quenching studies and the association constants calculated for CTD- p-CHL system is 36.2 × 10 3 mol L -1 and that for TMP- p-CHL system is 2.6 × 10 3 mol L -1. The kinetic results, in both the cases, indicated that the interaction is first order each with respect to the concentration of the donor and the acceptor. The physico-chemical parameters viz. oscillator strength, dipole moment, ionization potential and dissociation energy of the complexes were also determined and discussed. Structural characterization of the complexes were done using FT-IR and 1H NMR spectral techniques and the results indicated that, in TMP, the free NH 2 group while in CTD the pyrazole N sbnd H moiety involves in complexation with the acceptor, p-CHL.