Ragno, Daniele; Bortolini, Olga; Giovannini, Pier Paolo; Massi, Alessandro; Pacifico, Salvatore; Zaghi, Anna
2014-08-14
An operationally simple one-pot, two-step procedure for the desymmetrization of benzils is herein described. This consists in the chemoselective cross-benzoin reaction of symmetrical benzils with aromatic aldehydes catalyzed by the methyl sulfinyl (dimsyl) anion, followed by microwave-assisted oxidation of the resulting benzoylated benzoins with nitrate, avoiding the costly isolation procedure. Both electron-withdrawing and electron-donating substituents may be accommodated on the aromatic rings of the final unsymmetrical benzil.
Uteng, Marianne; Hauge, Håvard Hildeng; Brondz, Ilia; Nissen-Meyer, Jon; Fimland, Gunnar
2002-01-01
A rapid and simple two-step procedure suitable for both small- and large-scale purification of pediocin-like bacteriocins and other cationic peptides has been developed. In the first step, the bacterial culture was applied directly on a cation-exchange column (1-ml cation exchanger per 100-ml cell culture). Bacteria and anionic compounds passed through the column, and cationic bacteriocins were subsequently eluted with 1 M NaCl. In the second step, the bacteriocin fraction was applied on a low-pressure, reverse-phase column and the bacteriocins were detected as major optical density peaks upon elution with propanol. More than 80% of the activity that was initially in the culture supernatant was recovered in both purification steps, and the final bacteriocin preparation was more than 90% pure as judged by analytical reverse-phase chromatography and capillary electrophoresis. PMID:11823243
Finzi, Andrés; Cloutier, Jonathan; Cohen, Eric A
2003-07-01
The Nef protein encoded by human immunodeficiency virus type 1 (HIV-1) has been shown to be an important factor of progression of viral growth and pathogenesis in both in vitro and in vivo. The lack of a simple procedure to purify Nef in its native conformation has limited molecular studies on Nef function. A two-step procedure that includes heparin and immobilized metal ion affinity chromatographies (IMACs) was developed to purify His-tagged Nef (His(6)-Nef) expressed in bacteria in native condition. During the elaboration of this purification procedure, we identified two closely SDS-PAGE-migrating contaminating bacterial proteins, SlyD and GCHI, that co-eluted with His(6)-Nef in IMAC in denaturing condition and developed purification steps to eliminate these contaminants in native condition. Overall, this study describes a protocol that allows rapid purification of His(6)-Nef protein expressed in bacteria in native condition and that removes metal affinity resin-binding bacterial proteins that can contaminate recombinant His-tagged protein preparation.
a procedure for the analysis of (PCDDs/PCDFs) in soil at 500 ppt (pg/g) using a simple onestep liquid phase oxidative cleanup or, at mid to low ppt levels, using a two step coupled column cleanup (oxidation and activated carbon binding)
Jig-Shape Optimization of a Low-Boom Supersonic Aircraft
NASA Technical Reports Server (NTRS)
Pak, Chan-gi
2018-01-01
A simple approach for optimizing the jig-shape is proposed in this study. This simple approach is based on an unconstrained optimization problem and applied to a low-boom supersonic aircraft. In this study, the jig-shape optimization is performed using the two-step approach. First, starting design variables are computed using the least squares surface fitting technique. Next, the jig-shape is further tuned using a numerical optimization procedure based on in-house object-oriented optimization tool.
Crouse, C A; Ban, J D; D'Alessio, J K
1993-10-01
Sonication procedures for the extraction of DNA from forensic-type semen specimens have been developed, which, when compared to currently utilized sperm DNA extraction techniques, are simple, rapid and result in comparable DNA yields. Sperm DNA extraction by sonication was performed on whole semen, seminal stains, buccal swabs and post-coital specimens. Ultrasound disruption of sperm cells and their ultimate release of cellular DNA has been conducted in the presence of sperm wash buffers followed by organic extraction or Chelex 100 with little or no compromise to DNA quality, quantity or amplifiability. Two advantages of sonication over currently used forensic techniques to extract sperm DNA include 1) sperm DNA extraction that occurs within five minutes of sonication compared with an hour or greater for water bath incubations in classic enzyme digestion DNA extractions and 2) one less preparatory step with the Chelex/sonication protocol and three less steps with the sonication/organic protocol compared with other procedures thus eliminating potential sample-to-sample cross-contamination. Sperm DNA extracted by optimum sonication procedures was used for forensic HLA DQ alpha typing and restriction fragment length polymorphisms analysis without any adverse effects on typing results.
Realpe, Alba; Adams, Ann; Wall, Peter; Griffin, Damian; Donovan, Jenny L
2016-08-01
How a randomized controlled trial (RCT) is explained to patients is a key determinant of recruitment to that trial. This study developed and implemented a simple six-step model to fully inform patients and to support them in deciding whether to take part or not. Ninety-two consultations with 60 new patients were recorded and analyzed during a pilot RCT comparing surgical and nonsurgical interventions for hip impingement. Recordings were analyzed using techniques of thematic analysis and focused conversation analysis. Early findings supported the development of a simple six-step model to provide a framework for good recruitment practice. Model steps are as follows: (1) explain the condition, (2) reassure patients about receiving treatment, (3) establish uncertainty, (4) explain the study purpose, (5) give a balanced view of treatments, and (6) Explain study procedures. There are also two elements throughout the consultation: (1) responding to patients' concerns and (2) showing confidence. The pilot study was successful, with 70% (n = 60) of patients approached across nine centers agreeing to take part in the RCT, so that the full-scale trial was funded. The six-step model provides a promising framework for successful recruitment to RCTs. Further testing of the model is now required. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
A template-free solid-state synthesis of a morphologically controlled and highly organized iron(III)oxide micro–mesoporous Fenton catalyst has been engineered through a simple two-step synthetic procedure. The 3D nanoassembly of hematite nanoparticles (5–7 nm) organized into a ro...
Mechanochemical synthesis and intercalation of Ca(II)Fe(III)-layered double hydroxides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferencz, Zs.; Szabados, M.; Varga, G.
2016-01-15
A mechanochemical method (grinding the components without added water – dry grinding, followed by further grinding in the presence of minute amount of water or NaOH solution – wet grinding) was used in this work for the preparation and intercalation of CaFe-layered double hydroxides (LDHs). Both the pristine LDHs and the amino acid anion (cystinate and tyrosinate) intercalated varieties were prepared by the two-step grinding procedure in a mixer mill. By systematically changing the conditions of the preparation method, a set of parameters could be determined, which led to the formation of close to phase-pure LDH. The optimisation procedure wasmore » also applied for the intercalation processes of the amino acid anions. The resulting materials were structurally characterised by a range of methods (X-ray diffractometry, scanning electron microscopy, energy dispersive analysis, thermogravimetry, X-ray absorption and infra-red spectroscopies). It was proven that this simple mechanochemical procedure was able to produce complex organic–inorganic nanocomposites: LDHs intercalated with amino acid anions. - Graphical abstract: Amino acid anion-Ca(II)Fe(III)-LDHs were successfully prepared by a two-step milling procedure. - Highlights: • Synthesis of pristine and amino acid intercalated CaFe-LDHs by two-step milling. • Identifying the optimum synthesis and intercalation parameters. • Characterisation of the samples with a range of instrumental methods.« less
Using a Five-Step Procedure for Inferential Statistical Analyses
ERIC Educational Resources Information Center
Kamin, Lawrence F.
2010-01-01
Many statistics texts pose inferential statistical problems in a disjointed way. By using a simple five-step procedure as a template for statistical inference problems, the student can solve problems in an organized fashion. The problem and its solution will thus be a stand-by-itself organic whole and a single unit of thought and effort. The…
Isolation of plasmodesmata from Arabidopsis suspension culture cells.
Grison, Magali S; Fernandez-Calvino, Lourdes; Mongrand, Sébastien; Bayer, Emmanuelle M F
2015-01-01
Due to their position firmly anchored within the plant cell wall, plasmodesmata (PD) are notoriously difficult to isolate from plant tissue. Yet, getting access to isolated PD represents the most straightforward strategy for the identification of their molecular components. Proteomic and lipidomic analyses of such PD fractions have provided and will continue to provide critical information on the functional and structural elements that define these membranous nano-pores. Here, we describe a two-step simple purification procedure that allows isolation of pure PD-derived membranes from Arabidopsis suspension cells. The first step of this procedure consists in isolating cell wall fragments containing intact PD while free of contamination from other cellular compartments. The second step relies on an enzymatic degradation of the wall matrix and the subsequent release of "free" PD. Isolated PD membranes provide a suitable starting material for the analysis of PD-associated proteins and lipids.
Fluoroscopy guided percutaneous renal access in prone position
Sharma, Gyanendra R; Maheshwari, Pankaj N; Sharma, Anshu G; Maheshwari, Reeta P; Heda, Ritwik S; Maheshwari, Sakshi P
2015-01-01
Percutaneous nephrolithotomy is a very commonly done procedure for management of renal calculus disease. Establishing a good access is the first and probably the most crucial step of this procedure. A proper access is the gateway to success. However, this crucial step has the steepest learning curve for, in a fluoroscopy guided access, it involves visualizing a three dimensional anatomy on a two dimensional fluoroscopy screen. This review describes the anatomical basis of the renal access. It provides a literature review of all aspects of percutaneous renal access along with the advances that have taken place in this field over the years. The article describes a technique to determine the site of skin puncture, the angle and depth of puncture using a simple mathematical principle. It also reviews the common problems faced during the process of puncture and dilatation and describes the ways to overcome them. The aim of this article is to provide the reader a step by step guide for percutaneous renal access. PMID:25789297
Nanocrystal synthesis in microfluidic reactors: where next?
Phillips, Thomas W; Lignos, Ioannis G; Maceiczyk, Richard M; deMello, Andrew J; deMello, John C
2014-09-07
The past decade has seen a steady rise in the use of microfluidic reactors for nanocrystal synthesis, with numerous studies reporting improved reaction control relative to conventional batch chemistry. However, flow synthesis procedures continue to lag behind batch methods in terms of chemical sophistication and the range of accessible materials, with most reports having involved simple one- or two-step chemical procedures directly adapted from proven batch protocols. Here we examine the current status of microscale methods for nanocrystal synthesis, and consider what role microreactors might ultimately play in laboratory-scale research and industrial production.
ERIC Educational Resources Information Center
Peters, Erin
2005-01-01
Deconstructing cookbook labs to require the students to be more thoughtful could break down perceived teacher barriers to inquiry learning. Simple steps that remove or disrupt the direct transfer of step-by-step procedures in cookbook labs make students think more critically about their process. Through trials in the author's middle school…
Sloan, Nikki L; Luthra, Sajinder K; McRobbie, Graeme; Pimlott, Sally L; Sutherland, Andrew
2017-10-05
An operationally simple, one-pot, two-step tandem procedure that allows the incorporation of radioactive iodine into aryl amines via stable diazonium salts is described. The mild conditions are tolerant of various functional groups and substitution patterns, allowing late-stage, rapid access to a wide range of 125 I-labelled aryl compounds and SPECT radiotracers.
Experimental calibration procedures for rotating Lorentz-force flowmeters
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.; ...
2017-07-14
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Experimental calibration procedures for rotating Lorentz-force flowmeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hvasta, M. G.; Slighton, N. T.; Kolemen, E.
Rotating Lorentz-force flowmeters are a novel and useful technology with a range of applications in a variety of different industries. However, calibrating these flowmeters can be challenging, time-consuming, and expensive. In this paper, simple calibration procedures for rotating Lorentz-force flowmeters are presented. These procedures eliminate the need for expensive equipment, numerical modeling, redundant flowmeters, and system down-time. Finally, the calibration processes are explained in a step-by-step manner and compared to experimental results.
Prediction of composite thermal behavior made simple
NASA Technical Reports Server (NTRS)
Chamis, C. C.
1981-01-01
A convenient procedure is described to determine the thermal behavior (thermal expansion coefficients and thermal stresses) of angleplied fiber composites using a pocket calculator. The procedure consists of equations and appropriate graphs for various ( + or - theta) ply combinations. These graphs present reduced stiffness and thermal expansion coefficients as functions of (+ or - theta) in order to simplify and expedite the use of the equations. The procedure is applicable to all types of balanced, symmetric fiber composites including interply and intraply hybrids. The versatility and generality of the procedure is illustrated using several step-by-step numerical examples.
Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng
2017-01-01
Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.
A numerical method for computing unsteady 2-D boundary layer flows
NASA Technical Reports Server (NTRS)
Krainer, Andreas
1988-01-01
A numerical method for computing unsteady two-dimensional boundary layers in incompressible laminar and turbulent flows is described and applied to a single airfoil changing its incidence angle in time. The solution procedure adopts a first order panel method with a simple wake model to solve for the inviscid part of the flow, and an implicit finite difference method for the viscous part of the flow. Both procedures integrate in time in a step-by-step fashion, in the course of which each step involves the solution of the elliptic Laplace equation and the solution of the parabolic boundary layer equations. The Reynolds shear stress term of the boundary layer equations is modeled by an algebraic eddy viscosity closure. The location of transition is predicted by an empirical data correlation originating from Michel. Since transition and turbulence modeling are key factors in the prediction of viscous flows, their accuracy will be of dominant influence to the overall results.
Joosten, H M; Nunez, M; Devreese, B; Van Beeumen, J; Marugg, J D
1996-01-01
A simple two-step procedure was developed to obtain pure enterocin 4, a bacteriocin produced by Enterococcus faecalis INIA 4. Chemical and genetic characterization revealed that the primary structure of enterocin 4 is identical to that of peptide antibiotic AS-48 from Enterococcus faecalis S-48. In contrast to the reported inhibitory spectrum of AS-48, enterocin 4 displayed no activity against gram-negative bacteria. PMID:8900014
NASA Astrophysics Data System (ADS)
Shenoy, U. Sandhya; Shetty, A. Nityananda
2018-03-01
Enhancement of thermal properties of conventional heat transfer fluids has become one of the important technical challenges. Since nanofluids offer a promising help in this regard, development of simpler and hassle free routes for their synthesis is of utmost importance. Synthesis of nanofluids using a hassle free route with greener chemicals has been reported. The single-step chemical approach reported here overcomes the drawbacks of the two-step procedures in the synthesis of nanofluids. The resulting Newtonian nanofluids prepared contained cuboctahedral particles of cuprous oxide and exhibited a thermal conductivity of 2.852 W·m-1·K-1. Polyvinylpyrrolidone (PVP) used during the synthesis acted as a stabilizing agent rendering the nanofluid a stability of 9 weeks.
NASA Technical Reports Server (NTRS)
Chang, S. C.
1986-01-01
A two-step semidirect procedure is developed to accelerate the one-step procedure described in NASA TP-2529. For a set of constant coefficient model problems, the acceleration factor increases from 1 to 2 as the one-step procedure convergence rate decreases from + infinity to 0. It is also shown numerically that the two-step procedure can substantially accelerate the convergence of the numerical solution of many partial differential equations (PDE's) with variable coefficients.
Zhang, Yan; Zhang, Ting; Feng, Yanye; Lu, Xiuxiu; Lan, Wenxian; Wang, Jufang; Wu, Houming; Cao, Chunyang; Wang, Xiaoning
2011-01-01
The production of recombinant proteins in a large scale is important for protein functional and structural studies, particularly by using Escherichia coli over-expression systems; however, approximate 70% of recombinant proteins are over-expressed as insoluble inclusion bodies. Here we presented an efficient method for generating soluble proteins from inclusion bodies by using two steps of denaturation and one step of refolding. We first demonstrated the advantages of this method over a conventional procedure with one denaturation step and one refolding step using three proteins with different folding properties. The refolded proteins were found to be active using in vitro tests and a bioassay. We then tested the general applicability of this method by analyzing 88 proteins from human and other organisms, all of which were expressed as inclusion bodies. We found that about 76% of these proteins were refolded with an average of >75% yield of soluble proteins. This “two-step-denaturing and refolding” (2DR) method is simple, highly efficient and generally applicable; it can be utilized to obtain active recombinant proteins for both basic research and industrial purposes. PMID:21829569
Redo Laparoscopic Gastric Bypass: One-Step or Two-Step Procedure?
Theunissen, Caroline M J; Guelinckx, Nele; Maring, John K; Langenhoff, Barbara S
2016-11-01
The adjustable gastric band (AGB) is a bariatric procedure that used to be widely performed. However, AGB failure-signifying band-related complications or unsatisfactory weight loss, resulting in revision surgery (redo operations)-frequently occurs. Often this entails a conversion to a laparoscopic Roux-en-Y gastric bypass (LRYGB). This can be performed as a one-step or two-step (separate band removal) procedure. Data were collected from patients operated from 2012 to 2014 in a single bariatric centre. We compared 107 redo LRYGB after AGB failure with 1020 primary LRYGB. An analysis was performed of the one-step vs. two-step redo procedures. All redo procedures were performed by experienced bariatric surgeons. No difference in major complication rate was seen (2.8 vs. 2.3 %, p = 0.73) between redo and primary LRYGB, and overall complication severity for redos was low (mainly Clavien-Dindo 1 or 2). Weight loss results were comparable for primary and redo procedures. The one-step and two-step redos were comparable regarding complication rates and readmissions. The operating time for the one-step redo LRYGB was 136 vs. 107.5 min for the two-step (median, p < 0.001), excluding the operating time of separate AGB removal (mean 61 min, range 36-110). Removal of a failed AGB and LRYGB in a one-step procedure is safe when performed by experienced bariatric surgeons. However, when erosion or perforation of the AGB occurs, we advise caution and would perform the redo LRYGB as a two-step procedure. Equal weights can be achieved at 1 year post redo LRYGB as after primary LRYGB procedures.
Wiriyakun, Natta; Nacapricha, Duangjai; Chantiwas, Rattikan
2016-12-01
This work presents a simple hot embossing method with a shrinking procedure to produce cross-shape microchannels on poly(methyl methacrylate) (PMMA) substrate for the fabrication of an electrophoresis chip. The proposed method employed a simple two-step hot embossing technique, carried out consecutively on the same piece of substrate to make the crossing channels. Studies of embossing conditions, i.e. temperature, pressure and time, were carried out to investigate their effects on the dimension of the microchannels. Applying a simple shrinking procedure reduced the size of the channels from 700±20µm wide×150±5µm deep to 250±10µm wide×30±2µm deep, i.e. 80% and 64% reduction in the depth and width, respectively. Thermal fusion was employed to bond the PMMA substrate with a PMMA cover plate to produce the microfluidic device. Replication of microchip was achieved by precise control of conditions in the fabrication process (pressure, temperature and time), resulting in lower than 7% RSD of channel dimension, width and depth (n =10 devices). The method was simple and robust without the use of expensive equipment to construct the microstructure on a thermoplastic substrate. The PMMA microchip was used for demonstration of amine functionalization on the PMMA surface, measurement of electroosmotic flow and for electrophoretic separation of amino acids in functional drink samples. The precision of migration time and peak area of the amino acids, Lys, Ile and Phe at 125μM to 500μM, were in the range 3.2-4.2% RSD (n=9 devices) and 4.5-5.3% RSD (n=9 devices), respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Curcó, David; Casanovas, Jordi; Roca, Marc; Alemán, Carlos
2005-07-01
A method for generating atomistic models of dense amorphous polymers is presented. The method is organized in a two-steps procedure. First, structures are generated using an algorithm that minimizes the torsional strain. After this, a relaxation algorithm is applied to minimize the non-bonding interactions. Two alternative relaxation methods, which are based simple minimization and Concerted Rotation techniques, have been implemented. The performance of the method has been checked by simulating polyethylene, polypropylene, nylon 6, poly(L,D-lactic acid) and polyglycolic acid.
Determining irrigation distribution uniformity and efficiency for nurseries
R. Thomas Fernandez
2010-01-01
A simple method for testing the distribution uniformity of overhead irrigation systems is described. The procedure is described step-by-step along with an example. Other uses of distribution uniformity testing are presented, as well as common situations that affect distribution uniformity and how to alleviate them.
Liu, Zhiyi; Zhang, Luyao; Liu, Yanling; Gu, Yang; Sun, Tieliang
2017-11-01
We aimed to evaluate the efficiency and safety of one-step procedure combined endoscopic retrograde cholangiopancreatography (ERCP) and laparoscopic cholecystectomy (LC) for treatment of patients with cholecysto-choledocholithiasis. A prospective randomized study was performed on 63 consecutive cholecysto-choledocholithiasis patients during 2008 and 2011. The efficiency and safety of one-step procedure was assessed by comparing the two-step LC with ERCP + endoscopic sphincterotomy (EST). Outcomes including intraoperative features, postoperative features (length of stay and postoperative complications) were evaluated. One- or two-step procedure of LC with ERCP + EST was successfully performed in all patients, and common bile duct stones were completely removed. Statistical analyses showed that length of stay and pulmonary infection rate were significantly lower in the test group compared with that in the control group (P < 0.05), whereas no statistical difference in other outcomes was found between the two groups (all P > 0.05). The one-step procedure of LC with ERCP + EST is superior to the two-step procedure for treatment of patients with cholecysto-choledocholithiasis regarding to the reduced hospital stay and inhibited occurrence of pulmonary infections. Compared with two-step procedure, one-step procedure of LC with ERCP + EST may be a superior option for cholecysto-choledocholithiasis patients treatment regarding to hospital stay and pulmonary infections.
Skill Sheets for Agricultural Mechanics.
ERIC Educational Resources Information Center
Iowa State Univ. of Science and Technology, Ames. Dept. of Agricultural Education.
This set of 33 skill sheets for agricultural mechanics was developed for use in high school and vocational school agricultural mechanics programs. Some sheets teach operational procedures while others are for simple projects. Each skill sheet covers a single topic and includes: (1) a diagram, (2) a step-by-step construction or operational…
Liu, Yu; Li, Ji-Jia; Zu, Peng; Liu, Hong-Xu; Yu, Zhan-Wu; Ren, Yi
2017-12-07
To introduce a two-step method for creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy and assess its clinical application. One hundred and twenty-two patients with middle or lower esophageal cancer who underwent laparoscopic-thoracoscopic Ivor-Lewis esophagectomy at Liaoning Cancer Hospital and Institute from March 2014 to March 2016 were included in this study, and divided into two groups based on the procedure used for creating a gastric tube. One group used a two-step method for creating a gastric tube, and the other group used the conventional method. The two groups were compared regarding the operating time, surgical complications, and number of stapler cartridges used. The mean operating time was significantly shorter in the two-step method group than in the conventional method group [238 (179-293) min vs 272 (189-347) min, P < 0.01]. No postoperative death occurred in either group. There was no significant difference in the rate of complications [14 (21.9%) vs 13 (22.4%), P = 0.55] or mean number of stapler cartridges used [5 (4-6) vs 5.2 (5-6), P = 0.007] between the two groups. The two-step method for creating a gastric tube during laparoscopic-thoracoscopic Ivor-Lewis esophagectomy has the advantages of simple operation, minimal damage to the tubular stomach, and reduced use of stapler cartridges.
A comparison of simple global kinetic models for coal devolatilization with the CPD model
Richards, Andrew P.; Fletcher, Thomas H.
2016-08-01
Simulations of coal combustors and gasifiers generally cannot incorporate the complexities of advanced pyrolysis models, and hence there is interest in evaluating simpler models over ranges of temperature and heating rate that are applicable to the furnace of interest. In this paper, six different simple model forms are compared to predictions made by the Chemical Percolation Devolatilization (CPD) model. The model forms included three modified one-step models, a simple two-step model, and two new modified two-step models. These simple model forms were compared over a wide range of heating rates (5 × 10 3 to 10 6 K/s) at finalmore » temperatures up to 1600 K. Comparisons were made of total volatiles yield as a function of temperature, as well as the ultimate volatiles yield. Advantages and disadvantages for each simple model form are discussed. In conclusion, a modified two-step model with distributed activation energies seems to give the best agreement with CPD model predictions (with the fewest tunable parameters).« less
Boundary condition computational procedures for inviscid, supersonic steady flow field calculations
NASA Technical Reports Server (NTRS)
Abbett, M. J.
1971-01-01
Results are given of a comparative study of numerical procedures for computing solid wall boundary points in supersonic inviscid flow calculatons. Twenty five different calculation procedures were tested on two sample problems: a simple expansion wave and a simple compression (two-dimensional steady flow). A simple calculation procedure was developed. The merits and shortcomings of the various procedures are discussed, along with complications for three-dimensional and time-dependent flows.
A Simple Acronym for Doing Calculus: CAL
ERIC Educational Resources Information Center
Hathaway, Richard J.
2008-01-01
An acronym is presented that provides students a potentially useful, unifying view of the major topics covered in an elementary calculus sequence. The acronym (CAL) is based on viewing the calculus procedure for solving a calculus problem P* in three steps: (1) recognizing that the problem cannot be solved using simple (non-calculus) techniques;…
Teaching BASIC. A Step by Step Guide.
ERIC Educational Resources Information Center
Allen, M. F.
This three-chapter guide provides simple explanations about BASIC programming for a teacher to use in a classroom situation, and suggests procedures for a "hands-on" course. Numerous examples are presented of the questions, problems, and level of understanding to expect from first-time, adult users (ages 13 and up). The course materials…
Tu, Xijuan; Ma, Shuangqin; Gao, Zhaosheng; Wang, Jing; Huang, Shaokang; Chen, Wenbin
2017-11-01
Flavonoids are frequently found as glycosylated derivatives in plant materials. To determine contents of flavonoid aglycones in these matrices, procedures for the extraction and hydrolysis of flavonoid glycosides are required. The current sample preparation method is both labour and time consuming. Develop a modified matrix solid phase dispersion (MSPD) procedure as an alternative methodology for the one-step extraction and hydrolysis of flavonoid glycosides. HPLC-DAD was applied for demonstrating the one-step extraction and hydrolysis of flavonoids in rape bee pollen. The obtained contents of flavonoid aglycones (quercetin, kaempferol, isorhamnetin) were used for the optimisation and validation of the method. The extraction and hydrolysis were accomplished in one step. The procedure completes in 2 h with silica gel as dispersant, a 1:2 ratio of sample to dispersant, and 60% aqueous ethanol with 0.3 M hydrochloric acid as the extraction solution. The relative standard deviations (RSDs) of repeatability were less than 5%, and the recoveries at two fortified levels were between 88.3 and 104.8%. The proposed methodology is simple and highly efficient, with good repeatability and recovery. Compared with currently available methods, the present work has advantages of using less time and labour, higher extraction efficiency, and less consumption of the acid catalyst. This method may have applications for the one-step extraction and hydrolysis of bioactive compounds from plant materials. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
The Fibrin slide assay for detecting urokinase activity in human fetal kidney cells
NASA Technical Reports Server (NTRS)
Sedor, K.
1985-01-01
The Fibrin Slide Technique of Hau C. Kwaan and Tage Astrup is discussed. This relatively simple assay involves two steps: the formation of an artificial clot and then the addition of an enzyme (UKOKINASE) to dissolve the clot. The actual dissolving away of the clot is detected by the appearance of holes (lysis zones) in the stained clot. The procedure of Kwaan and Astrup is repeated, along with modifications and suggestions for improvements based on experience with the technique.
Kaur, Tanpreet; Gautam, Ram Nayan; Sharma, Anuj
2016-10-20
A facile route for the assembly of new bis-heterocyclic imidazo[2,1-b][1,3]thiazinyl/benzothiazoyl-phenyl)benzamide scaffolds through a two-step Groebke-Blackburn-Bienaymé (GBB)/Ugi reaction sequence is reported, which establishes multiple points of diversity in the final products. The highlights of this procedure are the survival of the aldehyde group following the GBB reaction without the need for additional protection/deprotection steps. Moreover, the reaction is operationally simple, with the absence of any catalyst, and exhibits excellent functional-group tolerance under minutes of microwave irradiation. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cardinale, Jens; Martin, René; Remde, Yvonne; Schäfer, Martin; Hienzsch, Antje; Hübner, Sandra; Zerges, Anna-Maria; Marx, Heike; Hesse, Ronny; Weber, Klaus; Smits, Rene; Hoepping, Alexander; Müller, Marco; Neels, Oliver C.; Kopka, Klaus
2017-01-01
Radiolabeled tracers targeting the prostate-specific membrane antigen (PSMA) have become important radiopharmaceuticals for the PET-imaging of prostate cancer. In this connection, we recently developed the fluorine-18-labelled PSMA-ligand [18F]PSMA-1007 as the next generation radiofluorinated Glu-ureido PSMA inhibitor after [18F]DCFPyL and [18F]DCFBC. Since radiosynthesis so far has been suffering from rather poor yields, novel procedures for the automated radiosyntheses of [18F]PSMA-1007 have been developed. We herein report on both the two-step and the novel one-step procedures, which have been performed on different commonly-used radiosynthesisers. Using the novel one-step procedure, the [18F]PSMA-1007 was produced in good radiochemical yields ranging from 25 to 80% and synthesis times of less than 55 min. Furthermore, upscaling to product activities up to 50 GBq per batch was successfully conducted. All batches passed quality control according to European Pharmacopoeia standards. Therefore, we were able to disclose a new, simple and, at the same time, high yielding production pathway for the next generation PSMA radioligand [18F]PSMA-1007. Actually, it turned out that the radiosynthesis is as easily realised as the well-known [18F]FDG synthesis and, thus, transferable to all currently-available radiosynthesisers. Using the new procedures, the clinical daily routine can be sustainably supported in-house even in larger hospitals by a single production batch. PMID:28953234
NASA Astrophysics Data System (ADS)
Koziel, Slawomir; Bekasiewicz, Adrian
2018-02-01
In this article, a simple yet efficient and reliable technique for fully automated multi-objective design optimization of antenna structures using sequential domain patching (SDP) is discussed. The optimization procedure according to SDP is a two-step process: (i) obtaining the initial set of Pareto-optimal designs representing the best possible trade-offs between considered conflicting objectives, and (ii) Pareto set refinement for yielding the optimal designs at the high-fidelity electromagnetic (EM) simulation model level. For the sake of computational efficiency, the first step is realized at the level of a low-fidelity (coarse-discretization) EM model by sequential construction and relocation of small design space segments (patches) in order to create a path connecting the extreme Pareto front designs obtained beforehand. The second stage involves response correction techniques and local response surface approximation models constructed by reusing EM simulation data acquired in the first step. A major contribution of this work is an automated procedure for determining the patch dimensions. It allows for appropriate selection of the number of patches for each geometry variable so as to ensure reliability of the optimization process while maintaining its low cost. The importance of this procedure is demonstrated by comparing it with uniform patch dimensions.
Asadi, Sakine; Nojavan, Saeed
2016-06-07
In the present work, acidic and basic drugs were simultaneously extracted by a novel method of high efficiency herein referred to as two-step voltage dual electromembrane extraction (TSV-DEME). Optimizing effective parameters such as composition of organic liquid membrane, pH values of donor and acceptor solutions, voltage and duration of each step, the method had its figures of merit investigated in pure water, human plasma, wastewater, and breast milk samples. Simultaneous extraction of acidic and basic drugs was done by applying potentials of 150 V and 400 V for 6 min and 19 min as the first and second steps, respectively. The model compounds were extracted from 4 mL of sample solution (pH = 6) into 20 μL of each acceptor solution (32 mM NaOH for acidic drugs and 32 mM HCL for basic drugs). 1-Octanol was immobilized within the pores of a porous hollow fiber of polypropylene, as the supported liquid membrane (SLM) for acidic drugs, and 2-ethyle hexanol, as the SLM for basic drugs. The proposed TSV-DEME technique provided good linearity with the resulting correlation coefficients ranging from 0.993 to 0.998 over a concentration range of 1-1000 ng mL(-1). The limit of detections of the drugs were found to range within 0.3-1.5 ng mL(-1), while the corresponding repeatability ranged from 7.7 to 15.5% (n = 4). The proposed method was further compared to simple dual electromembrane extraction (DEME), indicating significantly higher recoveries for TSV-DEME procedure (38.1-68%), as compared to those of simple DEME procedure (17.7-46%). Finally, the optimized TSV-DEME was applied to extract and quantify model compounds in breast milk, wastewater, and plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Combating omission errors through task analysis and good reminders.
Reason, J
2002-03-01
Leaving out necessary task steps is the single most common human error type. Certain task steps possess characteristics that are more likely to provoke omissions than others, and can be identified in advance. The paper reports two studies. The first, involving a simple photocopier, established that failing to remove the last page of the original is the commonest omission. This step possesses four distinct error-provoking features that combine their effects in an additive fashion. The second study examined the degree to which everyday memory aids satisfy five features of a good reminder: conspicuity, contiguity, content, context, and countability. A close correspondence was found between the percentage use of strategies and the degree to which they satisfied these five criteria. A three stage omission management programme was outlined: task analysis (identifying discrete task steps) of some safety critical activity; assessing the omission likelihood of each step; and the choice and application of a suitable reminder. Such a programme is applicable to a variety of healthcare procedures.
Developing survey grids to substantiate freedom from exotic pests
John W. Coulston; Frank H. Koch; William D. Smith
2009-01-01
Systematic, hierarchical intensification of the Environmental Monitoring and Assessment Program hexagon for North America yields a simple procedure for developing national-scale survey grids. In this article, we describe the steps to create a national-scale survey grid using a risk map as the starting point. We illustrate the steps using an exotic pest example in which...
Manpower Information Manual. A Manual for Local Planning.
ERIC Educational Resources Information Center
Allred, Marcus D.; Myers, Christine F.
The step-by-step procedures contained in this manual are intended to develop a simple information system that can be used to collect and process the best possible factual data on the manpower needs of the community served by an educational institution, so that long-range planning of vocational curriculum and guidance can be based on what the jobs…
Jig-Shape Optimization of a Low-Boom Supersonic Aircraft
NASA Technical Reports Server (NTRS)
Pak, Chan-Gi
2018-01-01
A simple approach for optimizing the jig-shape is proposed in this study. This simple approach is based on an unconstrained optimization problem and applied to a low-boom supersonic aircraft. In this study, the jig-shape optimization is performed using the two-step approach. First, starting design variables are computed using the least-squares surface fitting technique. Next, the jig-shape is further tuned using a numerical optimization procedure based on an in-house object-oriented optimization tool. During the numerical optimization procedure, a design jig-shape is determined by the baseline jig-shape and basis functions. A total of 12 symmetric mode shapes of the cruise-weight configuration, rigid pitch shape, rigid left and right stabilator rotation shapes, and a residual shape are selected as sixteen basis functions. After three optimization runs, the trim shape error distribution is improved, and the maximum trim shape error of 0.9844 inches of the starting configuration becomes 0.00367 inch by the end of the third optimization run.
Salat, Anna; Devoto, Walter; Manauta, Jordi
2011-01-01
Achieving similar features to those on natural teeth is a common problem with esthetic restorations. Color matching is a fundamental procedure required to perform a predictable composite resin restoration. It is no longer enough to measure these criteria with conventional shade guides, which provide the hue and chroma, but do not take into account other dimensions of the tooth such as value, intensives, opalescence and characterizations. The present article presents a simple and effective technique for color selection using a digital photograph of the tooth and an image-editing program such as Adobe Photoshop or Picture Project. The digital editing of the photograph with two simple steps described in this paper reveals the internal structures of the tooth easily. The modified photographs highlight the opalescence, white spots, shape of the internal mammelons and other features that are not visible at first glance. This procedure provides an accurate color chart with which the clinician can begin an esthetic restoration process.
Novel Fabry-Perot fiber optic sensor with multiple applications
NASA Astrophysics Data System (ADS)
Chen, Xiaopei; Shen, Fabin; Wang, Anbo; Wang, Zhuang; Zhang, Yan
2004-12-01
A novel Intrinsic Fabry-Perot fiber-optic sensor is presented in this paper. The sensors were made through two simple steps: wet chemical etch and fusion splice. Micro air-gaps were generated inside the fibers and functioned as reflective mirrors. This procedure not only provides a simple and cost effective technology for fabricating intrinsic Fabry-Perot Interferometric (IFPI) fiber sensors, but also provides two possible IFPI structures. Both of the fiber cavity between the air-gaps or the air-gap and cleaved fiber end can be used as sensing elements. With these two structures, this sensor can be used to measure the temperature, strain, pressure, refractive index of chemicals and the thin film thickness by itself. Multi-point measurements can also be achieved by multiplexing. Furthermore, it also can be multiplexed with other sensors such as Long Period Gratings (LPG) to provide compensations for other perturbation sensing. Theoretical and experimental studies of two sensor structures are described. Experimental results show that high resolution and high sensitivity can be obtained with appropriate signal processing.
ERIC Educational Resources Information Center
Young, Paul E.; Campbell, Andrew
1982-01-01
A simple, three-step procedure for synthesizing a dipeptide from its component amino acids is described. The dipeptide synthesized uses inexpensive amino acids having hydrocarbon side-chains and can be observed in E/Z forms by nuclear magnetic resonance spectroscopy. Each step in the synthesis produces white crystalline products using standard…
Virdi, Mandeep S; Sood, Meenakshi
2011-11-01
This study conducted at the PDM Dental College and Research Institute, Haryana, India, had the purpose of developing a teaching method based upon a five-step method for teaching clinical skills to students proposed by the American College of Surgeons. This five-step teaching method was used to place fissure sealants as an initial procedure by dental students in clinics. The sealant retention was used as an objective evaluation of the skill learnt by the students. The sealant retention was 92 percent at six- and twelve-month evaluations and 90 percent at the eighteen-month evaluation. These results indicate that simple methods can be devised for teaching clinical skills and achieve high success rates in clinical procedures requiring multiple steps.
Object-oriented software for evaluating measurement uncertainty
NASA Astrophysics Data System (ADS)
Hall, B. D.
2013-05-01
An earlier publication (Hall 2006 Metrologia 43 L56-61) introduced the notion of an uncertain number that can be used in data processing to represent quantity estimates with associated uncertainty. The approach can be automated, allowing data processing algorithms to be decomposed into convenient steps, so that complicated measurement procedures can be handled. This paper illustrates the uncertain-number approach using several simple measurement scenarios and two different software tools. One is an extension library for Microsoft Excel®. The other is a special-purpose calculator using the Python programming language.
Li, Siwei; Ding, Wentao; Zhang, Xueli; Jiang, Huifeng; Bi, Changhao
2016-01-01
Saccharomyces cerevisiae has already been used for heterologous production of fuel chemicals and valuable natural products. The establishment of complicated heterologous biosynthetic pathways in S. cerevisiae became the research focus of Synthetic Biology and Metabolic Engineering. Thus, simple and efficient genomic integration techniques of large number of transcription units are demanded urgently. An efficient DNA assembly and chromosomal integration method was created by combining homologous recombination (HR) in S. cerevisiae and Golden Gate DNA assembly method, designated as modularized two-step (M2S) technique. Two major assembly steps are performed consecutively to integrate multiple transcription units simultaneously. In Step 1, Modularized scaffold containing a head-to-head promoter module and a pair of terminators was assembled with two genes. Thus, two transcription units were assembled with Golden Gate method into one scaffold in one reaction. In Step 2, the two transcription units were mixed with modules of selective markers and integration sites and transformed into S. cerevisiae for assembly and integration. In both steps, universal primers were designed for identification of correct clones. Establishment of a functional β-carotene biosynthetic pathway in S. cerevisiae within 5 days demonstrated high efficiency of this method, and a 10-transcriptional-unit pathway integration illustrated the capacity of this method. Modular design of transcription units and integration elements simplified assembly and integration procedure, and eliminated frequent designing and synthesis of DNA fragments in previous methods. Also, by assembling most parts in Step 1 in vitro, the number of DNA cassettes for homologous integration in Step 2 was significantly reduced. Thus, high assembly efficiency, high integration capacity, and low error rate were achieved.
Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè
2016-01-01
The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation. Temporary stabilization with external fixator in 'tripolar' configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases.
Shaw, Fu-Zen; Yen, Chen Tung; Chen, Ruei Feng
2003-04-15
Simple and useful steps, i.e. placing a grounded plate under the recording chamber as well as using multiple reference electrodes, are introduced here for obtaining reliable low-noise recordings of brain activity in freely moving rats. A general circuit model was built to analyze the electrical interference of both single-grounded and two-reference ground-free recording configurations. In both simulated and realistic conditions under two recording states, 60-Hz magnitude was in the microvolt range. Moreover, the noise was significantly reduced by shortening the distance between the subject and the grounded plate under the recording chamber. Furthermore, in chronically implanted rats, average 60-Hz interference of multichannel electroencephalograms of two-reference ground-free recordings (3.74 +/- 0.18 microV) was significantly smaller than that of the single-grounded condition (9.03 +/- 1.98 microV). Thus, we demonstrated that a lower-noise recording can be achieved by a two-reference configuration and a closely-placed metal grounded plate in an open-field circumstance. As compared to the use of a Faraday cage, this simple procedure is of benefit for long-term behavioral tracking with a video camera and for pharmacological experiments.
Benhammouda, Brahim; Vazquez-Leal, Hector
2016-01-01
This work presents an analytical solution of some nonlinear delay differential equations (DDEs) with variable delays. Such DDEs are difficult to treat numerically and cannot be solved by existing general purpose codes. A new method of steps combined with the differential transform method (DTM) is proposed as a powerful tool to solve these DDEs. This method reduces the DDEs to ordinary differential equations that are then solved by the DTM. Furthermore, we show that the solutions can be improved by Laplace-Padé resummation method. Two examples are presented to show the efficiency of the proposed technique. The main advantage of this technique is that it possesses a simple procedure based on a few straight forward steps and can be combined with any analytical method, other than the DTM, like the homotopy perturbation method.
Solution of elliptic PDEs by fast Poisson solvers using a local relaxation factor
NASA Technical Reports Server (NTRS)
Chang, Sin-Chung
1986-01-01
A large class of two- and three-dimensional, nonseparable elliptic partial differential equations (PDEs) is presently solved by means of novel one-step (D'Yakanov-Gunn) and two-step (accelerated one-step) iterative procedures, using a local, discrete Fourier analysis. In addition to being easily implemented and applicable to a variety of boundary conditions, these procedures are found to be computationally efficient on the basis of the results of numerical comparison with other established methods, which lack the present one's: (1) insensitivity to grid cell size and aspect ratio, and (2) ease of convergence rate estimation by means of the coefficient of the PDE being solved. The two-step procedure is numerically demonstrated to outperform the one-step procedure in the case of PDEs with variable coefficients.
Boudjemline, Younes
2018-01-01
To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P < 0.001 for all variables). After a median follow-up of 8 months (range, 3-14.7), no patient underwent reintervention, and no device dysfunction was observed. The one-step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.
Endobronchial valves for bronchopleural fistula: pitfalls and principles.
Gaspard, Dany; Bartter, Thaddeus; Boujaoude, Ziad; Raja, Haroon; Arya, Rohan; Meena, Nikhil; Abouzgheib, Wissam
2017-01-01
Placement of endobronchial valves for bronchopleural fistula (BPF) is not always straightforward. A simple guide to the steps for an uncomplicated procedure does not encompass pitfalls that need to be understood and overcome to maximize the efficacy of this modality. The objective of this study was to discuss examples of difficult cases for which the placement of endobronchial valves was not straightforward and required alterations in the usual basic steps. Subsequently, we aimed to provide guiding principles for a successful procedure. Six illustrative cases were selected to demonstrate issues that can arise during endobronchial valve placement. In each case, a real or apparent lack of decrease in airflow through a BPF was diagnosed and addressed. We have used the selected problem cases to illustrate principles, with the goal of helping to increase the success rate for endobronchial valve placement in the treatment of BPF. This series demonstrates issues that complicate effective placement of endobronchial valves for BPF. These issues form the basis for troubleshooting steps that complement the basic procedural steps.
Tuzen, Mustafa; Uluozlu, Ozgur Dogan; Mendil, Durali; Soylak, Mustafa; Machado, Luana O R; Dos Santos, Walter N L; Ferreira, Sergio L C
2018-04-15
This paper proposes a simple, rapid and green ultrasound assisted and ionic liquid dispersive microextraction procedure using pyrocatechol violet (PV) as complexing reagent and 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)-imide [C 6 MIM][Tf 2 N] as ionic liquid for the detection of tin employing electrothermal atomic absorption spectrometry (ETAAS). The optimization step was performed using a two-level full factorial design involving the following factors: pH of the working media, amount reagents, ionic liquid volume and extraction time and the chemometric response was tin recovery. The procedure allowed the determination of tin with limits of detection and quantification of 3.4 and 11.3 ng L -1 , respectively. The relative standard deviation was 4.5% for a tin solution of 0.50 µg L -1 . The validation method was confirmed by analysis of rice flour certified reference material. The method was applied for the quantification of tin in several food samples. The concentration range found varied from 0.10 to 1.50 µg g -1 . Copyright © 2017 Elsevier Ltd. All rights reserved.
Glais, Laurent; Jacquot, Emmanuel
2015-01-01
Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.
Simple immunoassay for detection of PCBs in transformer oil.
Glass, Thomas R; Ohmura, Naoya; Taemi, Yukihiro; Joh, Takashi
2005-07-01
A rapid and inexpensive procedure to detect polychlorinated biphenyls (PCBs) in transformer oil is needed to facilitate identification and removal of PCB contaminated transformers. Here we describe a simple two-step liquid-liquid extraction using acidic dimethyl sulfoxide in conjunction with an immunoassay for detecting PCBs in transformer oil. The process described is faster and simpler than any previous immunoassay while maintaining comparable detection limit and false negative rate. Cross reactivity data, characterizing the immunoassay response to the four Kanechlor technical mixtures of PCBs in oil, are presented. Forty-five used transformer oil samples were analyzed by gas chromatography-high-resolution mass spectrometry and were also evaluated using the immunoassay protocol developed. Results presented show zero false negatives at a 1.4 ppm nominal cutoff for the transformer oils analyzed.
Vignali, Edda; Macchia, Enrico; Cetani, Filomena; Reggiardo, Giorgio; Cianferotti, Luisella; Saponaro, Federica; Marcocci, Claudio
2017-01-01
Sun exposure is the main determinant of vitamin D production. The aim of this study was to develop an algorithm to assess individual vitamin D status, independently of serum 25(OHD) measurement, using a simple questionnaire, mostly relying upon sunlight exposure, which might help select subjects requiring serum 25(OHD) measurement. Six hundred and twenty adult subjects living in a mountain village in Southern Italy, located at 954 m above the sea level and at a latitude of 40°50'11″76N, were asked to fill the questionnaire in two different periods of the year: August 2010 and March 2011. Seven predictors were considered: month of investigation, age, sex, BMI, average daily sunlight exposure, beach holidays in the past 12 months, and frequency of going outdoors. The statistical model assumes four classes of serum 25(OHD) concentrations: ≤10, 10-19.9, 20-29.9, and ≥30 ng/ml. The algorithm was developed using a two-step procedure. In Step 1, the linear regression equation was defined in 385 randomly selected subjects. In Step 2, the predictive ability of the regression model was tested in the remaining 235 subjects. Seasonality, daily sunlight exposure and beach holidays in the past 12 months accounted for 27.9, 13.5, and 6.4 % of the explained variance in predicting vitamin D status, respectively. The algorithm performed extremely well: 212 of 235 (90.2 %) subjects were assigned to the correct vitamin D status. In conclusion, our pilot study demonstrates that an algorithm to estimate the vitamin D status can be developed using a simple questionnaire based on sunlight exposure.
Comparison of Methods for Demonstrating Passage of Time When Using Computer-Based Video Prompting
ERIC Educational Resources Information Center
Mechling, Linda C.; Bryant, Kathryn J.; Spencer, Galen P.; Ayres, Kevin M.
2015-01-01
Two different video-based procedures for presenting the passage of time (how long a step lasts) were examined. The two procedures were presented within the framework of video prompting to promote independent multi-step task completion across four young adults with moderate intellectual disability. The two procedures demonstrating passage of the…
Luo, Ming-Jiu; Liu, Na; Miao, De-Qiang; Lan, Guo-Cheng; Suo-Feng; Chang, Zhong-Le; Tan, Jing-He
2005-09-01
Although ethylene glycol (EG) has been widely used for embryo cryopreservation in domestic animals, few attempts were made to use this molecule to freeze mouse and human embryos. In the few studies that used EG for slow-freezing of mouse and human embryos, complicated protocols for human embryos were used, and the protocols need to be simplified. Besides, freezing mouse morula with EG as a cryoprotectant has not been reported. In this paper, we studied the effects of embryo stages, EG concentration, duration and procedure of equilibration, sucrose supplementation and EG removal after thawing on the development of thawed mouse embryos, using the simple freezing and thawing procedures for bovine embryos. The blastulation and hatching rates (81.92% +/- 2.24% and 68.56% +/- 2.43%, respectively) of the thawed late compact morulae were significantly (P < 0.05) higher than those of embryos frozen-thawed at other stages. When mouse late compact morulae were frozen with different concentrations of EG, the highest rates of blastocyst formation and hatching were obtained with 1.8mol/L EG. The blastulation rate was significantly higher when late morulae were equilibrated in 1.8 mol/L EG for 10 min prior to freezing than when they were equilibrated for 30 min, and the hatching rate of embryos exposed to EG for 10 min was significantly higher than that of embryos exposed for 20 and 30 min. Both rates of blastocyst formation and hatching obtained with two-step equilibration were higher (P < 0.05) than with one-step equilibration in 1.8 mol/L EG. Addition of sucrose to the EG-based solution had no beneficial effects. On the contrary, an increased sucrose level (0.4 mol/L) in the solution impaired the development of the frozen-thawed embryos. In contrast, addition of 0.1 mol/L sucrose to the propylene glycol (PG)-based solution significantly improved the development of the frozen-thawed embryos. Elimination of the cryoprotectant after thawing did not improve the development of the thawed embryos. The cell numbers were less (P < 0.05) in blastocysts developed from the thawed morulae than in the in vivo derived ones. In summary, embryo stage, EG concentration, duration and procedure of equilibration and sucrose supplementation had marked effects on development of the thawed mouse embryos, and a protocol for cryopreservation of mouse embryos is recommended in which the late morulae are frozen in 1.8 mol/L EG using the simple freezing and thawing procedures of bovine embryos after a two-step equilibration and the embryos can be cultured or transferred without EG removal after thawing.
Fisher, E R; Sass, R; Fisher, B
1985-09-01
Investigation of the biologic significance of delay between biopsy and mastectomy was performed upon women with invasive carcinoma of the breast in protocol four of the NSABP. Since the period of delay was two weeks or less in approximately 75 per cent, no comment concerning the possible effects of longer periods can be made. Life table analyses failed to reveal any difference in ten year survival rates between patients undergoing radical mastectomy management by the one and two step procedures. Similarly, no difference in adjusted ten year survival rate was observed between women managed by the two step procedure who did or did not have residual tumor identified in the mastectomy specimen after the first step or biopsy. Importantly, the clinical or pathologic stages, sizes of tumor or histologic grades were similar in women managed by the one and two step procedures minimizing selection bias. The material used also allowed for study of the possible causative role of biopsy of the breast on the development of sinus histiocytosis in regional axillary lymph nodes. No difference in degree or types of this nodal reaction could be discerned in the lymph nodes of the mastectomy specimens obtained from patients who had undergone the one and two step procedures. This finding indicates that nodal sinus histiocytosis is indeed related to the neoplastic process, albeit in an undefined manner, rather than the trauma of biopsy per se as has been suggested. These results do not invalidate the use of the one step procedure in the management of patients with carcinoma of the breast. Indeed, it is highly likely that it will be commonly used now that breast-conserving operations appear to represent a viable alternative modality for the primary surgical treatment of carcinoma of the breast. Yet, it is apparent that the one step procedure will be performed for technical and practical rather than biologic reasons.
Sun, Boqiao; Kantzow, Christina; Bresch, Sven; Castiglione, Kathrin; Weuster-Botz, Dirk
2013-01-01
Ursodeoxycholic acid (UDCA) is a bile acid of industrial interest as it is used as an agent for the treatment of primary sclerosing cholangitis and the medicamentous, non-surgical dissolution of gallstones. Currently, it is prepared industrially from cholic acid following a seven-step chemical procedure with an overall yield of <30%. In this study, we investigated the key enzymatic steps in the chemo-enzymatic preparation of UDCA-the two-step reduction of dehydrocholic acid (DHCA) to 12-keto-ursodeoxycholic acid using a mutant of 7β-hydroxysteroid dehydrogenase (7β-HSDH) from Collinsella aerofaciens and 3α-hydroxysteroid dehydrogenase (3α-HSDH) from Comamonas testosteroni. Three different one-pot reaction approaches were investigated using whole-cell biocatalysts in simple batch processes. We applied one-biocatalyst systems, where 3α-HSDH, 7β-HSDH, and either a mutant of formate dehydrogenase (FDH) from Mycobacterium vaccae N10 or a glucose dehydrogenase (GDH) from Bacillus subtilis were expressed in a Escherichia coli BL21(DE3) based host strain. We also investigated two-biocatalyst systems, where 3α-HSDH and 7β-HSDH were expressed separately together with FDH enzymes for cofactor regeneration in two distinct E. coli hosts that were simultaneously applied in the one-pot reaction. The best result was achieved by the one-biocatalyst system with GDH for cofactor regeneration, which was able to completely convert 100 mM DHCA to >99.5 mM 12-keto-UDCA within 4.5 h in a simple batch process on a liter scale. Copyright © 2012 Wiley Periodicals, Inc.
Interventional radiology of the thorax.
Duncan, Mark; Wijesekera, Nevin; Padley, Simon
2010-04-01
Interventional radiology of the thorax encompasses an expanding variety of procedures, ranging from simple diagnostic pleural fluid aspiration to complex therapeutic procedures such as bronchial artery embolization and radiofrequency ablation of lung tumours. Physicians of many specialties will encounter patients undergoing such procedures and knowledge of possible complications is therefore desirable. We aim to briefly outline the role of the most commonly undertaken radiological thoracic interventions and review the associated complications, their subsequent management and the steps that can be taken to minimize the risk of these complications occurring.
Chemoselective synthesis of sialic acid 1,7-lactones.
Allevi, Pietro; Rota, Paola; Scaringi, Raffaella; Colombo, Raffaele; Anastasia, Mario
2010-08-20
The chemoselective synthesis of the 1,7-lactones of N-acetylneuraminic acid, N-glycolylneuraminic acid, and 3-deoxy-d-glycero-d-galacto-nononic acid is accomplished in two steps: a simple treatment of the corresponding free sialic acid with benzyloxycarbonyl chloride and a successive hydrogenolysis of the formed 2-benzyloxycarbonyl 1,7-lactone. The instability of the 1,7-lactones to protic solvents has been also evidenced together with the rationalization of the mechanism of their formation under acylation conditions. The results permit to dispose of authentic 1,7-sialolactones to be used as reference standards and of a procedure useful for the preparation of their isotopologues to be used as inner standards in improved analytical procedures for the gas liquid chromatography-mass spectrometry (GLC-MS) analysis of 1,7-sialolactones in biological media.
High-order time-marching reinitialization for regional level-set functions
NASA Astrophysics Data System (ADS)
Pan, Shucheng; Lyu, Xiuxiu; Hu, Xiangyu Y.; Adams, Nikolaus A.
2018-02-01
In this work, the time-marching reinitialization method is extended to compute the unsigned distance function in multi-region systems involving arbitrary number of regions. High order and interface preservation are achieved by applying a simple mapping that transforms the regional level-set function to the level-set function and a high-order two-step reinitialization method which is a combination of the closest point finding procedure and the HJ-WENO scheme. The convergence failure of the closest point finding procedure in three dimensions is addressed by employing a proposed multiple junction treatment and a directional optimization algorithm. Simple test cases show that our method exhibits 4th-order accuracy for reinitializing the regional level-set functions and strictly satisfies the interface-preserving property. The reinitialization results for more complex cases with randomly generated diagrams show the capability our method for arbitrary number of regions N, with a computational effort independent of N. The proposed method has been applied to dynamic interfaces with different types of flows, and the results demonstrate high accuracy and robustness.
Microscale Organic Laboratory: IV. A Simple and Rapid Procedure for Carrying Out Wittig Reactions.
ERIC Educational Resources Information Center
Pike, R. M.; And Others
1986-01-01
Describes two examples where synthetic salt-base mixtures are used in a microscale organic laboratory program as a simple and quick procedure for carrying out Wittig reactions. Both experimental procedures are outlined and discussed. (TW)
Graphical correlation of gaging-station records
Searcy, James K.
1960-01-01
A gaging-station record is a sample of the rate of flow of a stream at a given site. This sample can be used to estimate the magnitude and distribution of future flows if the record is long enough to be representative of the long-term flow of the stream. The reliability of a short-term record for estimating future flow characteristics can be improved through correlation with a long-term record. Correlation can be either numerical or graphical, but graphical correlation of gaging-station records has several advantages. The graphical correlation method is described in a step-by-step procedure with an illustrative problem of simple correlation, illustrative problems of three examples of multiple correlation--removing seasonal effect--and two examples of correlation of one record with two other records. Except in the problem on removal of seasonal effect, the same group of stations is used in the illustrative problems. The purpose of the problems is to illustrate the method--not to show the improvement that can result from multiple correlation as compared with simple correlation. Hydrologic factors determine whether a usable relation exists between gaging-station records. Statistics is only a tool for evaluating and using an existing relation, and the investigator must be guided by a knowledge of hydrology.
Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè
2016-01-01
Background: The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. Methods: We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. Results: We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation Conclusion: Temporary stabilization with external fixator in ‘tripolar’ configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases. PMID:27123151
Xie, Jinbing; Lu, Yang; Wang, Wei; Zhu, Hui; Wang, Zhigang; Cao, Zhiqiang
2017-06-01
Polymer-protein conjugation has been extensively explored toward a better protein drug with improved pharmacokinetics. However, a major problem with polymer-protein conjugation is that the polymers drastically reduce the bioactivity of the modified protein. There is no perfect solution to prevent the bioactivity loss, no matter the polymer is conjugated in a non-site specific way, or a more complex site-specific procedure. Here the authors report for the first time that when zwitterionic carboxybetaine polymer (PCB) is conjugated to insulin through simple conventional coupling chemistry. The resulting PCB-insulin does not show a significant reduction of in vitro bioactivity. The obtained PCB-insulin shows two significant advantages as a novel pharmaceutical agent. First, its therapeutic performance is remarkable. For PCB-insulin, there is a 24% increase of in vivo pharmacological activity of lowering blood glucose compared with native insulin. Such uncommonly seen increase has rarely been reported and is expected to be due to both the improved pharmacokinetics and retained bioactivity of PCB-insulin. Second, the production is simple from manufacturing standpoints. Conjugation procedure involves only one-step coupling reaction without complex site-specific linkage technique. The synthesized PCB-insulin conjugates do not require chromatographic separation to purify and obtain particular isoforms. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Volume holographic elements in Kodak 131 plates processed with SHSG method
NASA Astrophysics Data System (ADS)
Collados, Manuel V.; Atencia, Jesus; Lopez, Ana M.; Quintanilla, Manuel M.
2001-08-01
A SHSG procedure to register volume phase holograms in Kodak 131 plates is presented. We analyze the influence on the diffraction efficiency of the developing step and the temperature of the bleaching bath of usual SHSG processes. Applying a simple 12 steps process to form phase transmission holograms developing with D-19, bleaching with R-10 at 70 degrees C and removing the sensitizing dyes that remain in the emulsion with a diluted methanol bath after the fixation step, we obtain relative efficiencies of 100 percent and effective efficiencies of 70 percent.
Endobronchial valves for bronchopleural fistula: pitfalls and principles
Gaspard, Dany; Bartter, Thaddeus; Boujaoude, Ziad; Raja, Haroon; Arya, Rohan; Meena, Nikhil; Abouzgheib, Wissam
2016-01-01
Background: Placement of endobronchial valves for bronchopleural fistula (BPF) is not always straightforward. A simple guide to the steps for an uncomplicated procedure does not encompass pitfalls that need to be understood and overcome to maximize the efficacy of this modality. Objectives: The objective of this study was to discuss examples of difficult cases for which the placement of endobronchial valves was not straightforward and required alterations in the usual basic steps. Subsequently, we aimed to provide guiding principles for a successful procedure. Methods: Six illustrative cases were selected to demonstrate issues that can arise during endobronchial valve placement. Results: In each case, a real or apparent lack of decrease in airflow through a BPF was diagnosed and addressed. We have used the selected problem cases to illustrate principles, with the goal of helping to increase the success rate for endobronchial valve placement in the treatment of BPF. Conclusions: This series demonstrates issues that complicate effective placement of endobronchial valves for BPF. These issues form the basis for troubleshooting steps that complement the basic procedural steps. PMID:27742781
Determination of cadmium in sediments by diluted HCI extraction and isotope dilution ICP-MS.
Terán-Baamonde, Javier; Soto-Ferreiro, Rosa-María; Carlosena, Alatzne; Andrade, José-Manuel; Prada, Darío
2018-08-15
Isotope dilution ICP-MS is proposed to measure the mass fraction of Cd extracted by diluted HCl in marine sediments, using a fast and simple extraction procedure based on ultrasonic probe agitation. The 111 Cd isotope was added before the extraction to achieve isotope equilibration with native Cd solubilized from the sample. The parameters affecting trueness and precision of isotope ratio measurements were evaluated carefully and subsequently corrected in order to minimize errors; they were: detector dead time, spectral interferences, mass discrimination factor and optimum sample/spike ratio. The mass fraction of Cd extracted was compared with the sum of the certified contents of the three steps of the sequential extraction procedure of the Standards, Measurements and Testing Programme (SM&T) analysing the BCR 701 sediment to validate the method. The certified and measured values agreed, giving a measured / certified mass fraction ratio of 1.05. Further, the extraction procedure itself was studied by adding the enriched isotope after the extraction step, which allowed verifying that analyte losses occurred during this process. Two additional reference sediments with certified total cadmium contents were also analysed. The method provided very good precision (0.9%, RSD) and a low detection limit, 1.8 ng g -1 . The procedural uncertainty budget was estimated following the EURACHEM Guide by means of the 'GUM Workbench' software, obtaining a relative expanded uncertainty of 1.5%. The procedure was applied to determine the bioaccessible mass fraction of Cd in sediments from two environmentally and economically important areas of Galicia (rias of Arousa and Vigo, NW of Spain). Copyright © 2018 Elsevier B.V. All rights reserved.
Ptaszek, Marcin; Bhaumik, Jayeeta; Kim, Han-Je; Taniguchi, Masahiko; Lindsey, Jonathan S.
2008-01-01
2,3,4,5-Tetrahydro-1,3,3-trimethyldipyrrin (1) is a crucial building block in the rational synthesis of chlorins and oxochlorins. The prior 5-step synthesis of 1 from pyrrole-2-carboxaldehyde (2) employed relatively simple and well-known reactions yet suffered from several drawbacks, including limited scale (≥ 0.5 g of 1 per run). A streamlined preparation of 1 has been developed that entails four steps: (i) nitro-aldol condensation of 2 and nitromethane under neat conditions to give 2-(2-nitrovinyl)pyrrole (3), (ii) reduction of 3 with NaBH4 to give 2-(2-nitroethyl)pyrrole (4), (iii) Michael addition of 4 with mesityl oxide under neat conditions or at high concentration to give γ-nitrohexanonepyrrole 5, and (iv) reductive cyclization of 5 with zinc/ammonium formate to give 1. Several multistep transformations have been established, including the direct conversion of 2 → 1. The advantages of the new procedures include (1) fewer steps, (2) avoidance of several problematic reagents, (3) diminished consumption of solvents and reagents, (4) lessened reliance on chromatography, and (5) scalability. The new procedures facilitate the preparation of 1 at the multigram scale. PMID:19132135
Schilardi, Patricia L; Dip, Patricio; dos Santos Claro, Paula C; Benítez, Guillermo A; Fonticelli, Mariano H; Azzaroni, Omar; Salvarezza, Roberto C
2005-12-16
Pattern transfer with high resolution is a frontier topic in the emerging field of nanotechnologies. Electrochemical molding is a possible route for nanopatterning metal, alloys and oxide surfaces with high resolution in a simple and inexpensive way. This method involves electrodeposition onto a conducting master covered by a self-assembled alkanethiolate monolayer (SAMs). This molecular film enables direct surface-relief pattern transfer from the conducting master to the inner face of the electrodeposit, and also allows an easy release of the electrodeposited film due their excellent anti-adherent properties. Replicas of the original conductive master can be also obtained by a simple two-step procedure. SAM quality and stability under electrodeposition conditions combined with the formation of smooth electrodeposits are crucial to obtain high-quality pattern transfer with sub-50 nm resolution.
Development of a Training Model for Laparoscopic Common Bile Duct Exploration
Rodríguez, Omaira; Benítez, Gustavo; Sánchez, Renata; De la Fuente, Liliana
2010-01-01
Background: Training and experience of the surgical team are fundamental for the safety and success of complex surgical procedures, such as laparoscopic common bile duct exploration. Methods: We describe an inert, simple, very low-cost, and readily available training model. Created using a “black box” and basic medical and surgical material, it allows training in the fundamental steps necessary for laparoscopic biliary tract surgery, namely, (1) intraoperative cholangiography, (2) transcystic exploration, and (3) laparoscopic choledochotomy, and t-tube insertion. Results: The proposed model has allowed for the development of the skills necessary for partaking in said procedures, contributing to its development and diminishing surgery time as the trainee advances down the learning curve. Further studies are directed towards objectively determining the impact of the model on skill acquisition. Conclusion: The described model is simple and readily available allowing for accurate reproduction of the main steps and maneuvers that take place during laparoscopic common bile duct exploration, with the purpose of reducing failure and complications. PMID:20529526
Alonso, Ariel; Van der Elst, Wim; Molenberghs, Geert; Buyse, Marc; Burzykowski, Tomasz
2016-09-01
In this work a new metric of surrogacy, the so-called individual causal association (ICA), is introduced using information-theoretic concepts and a causal inference model for a binary surrogate and true endpoint. The ICA has a simple and appealing interpretation in terms of uncertainty reduction and, in some scenarios, it seems to provide a more coherent assessment of the validity of a surrogate than existing measures. The identifiability issues are tackled using a two-step procedure. In the first step, the region of the parametric space of the distribution of the potential outcomes, compatible with the data at hand, is geometrically characterized. Further, in a second step, a Monte Carlo approach is proposed to study the behavior of the ICA on the previous region. The method is illustrated using data from the Collaborative Initial Glaucoma Treatment Study. A newly developed and user-friendly R package Surrogate is provided to carry out the evaluation exercise. © 2016, The International Biometric Society.
Simple Steps to a Successful Workshop. CSLA Guide.
ERIC Educational Resources Information Center
Lewis, Dorothy G.
This document provides guidelines for workshop planning. The first section, "Getting Started," discusses identifying needs, choosing the workshop format, setting goals, and forming a planning committee. The second section, "Procedure for the Planning Committee," lists seven main tasks. The third section, "Duties of the Personnel," outlines the…
Analysis of simple 2-D and 3-D metal structures subjected to fragment impact
NASA Technical Reports Server (NTRS)
Witmer, E. A.; Stagliano, T. R.; Spilker, R. L.; Rodal, J. J. A.
1977-01-01
Theoretical methods were developed for predicting the large-deflection elastic-plastic transient structural responses of metal containment or deflector (C/D) structures to cope with rotor burst fragment impact attack. For two-dimensional C/D structures both, finite element and finite difference analysis methods were employed to analyze structural response produced by either prescribed transient loads or fragment impact. For the latter category, two time-wise step-by-step analysis procedures were devised to predict the structural responses resulting from a succession of fragment impacts: the collision force method (CFM) which utilizes an approximate prediction of the force applied to the attacked structure during fragment impact, and the collision imparted velocity method (CIVM) in which the impact-induced velocity increment acquired by a region of the impacted structure near the impact point is computed. The merits and limitations of these approaches are discussed. For the analysis of 3-d responses of C/D structures, only the CIVM approach was investigated.
Testing the Stability of 2-D Recursive QP, NSHP and General Digital Filters of Second Order
NASA Astrophysics Data System (ADS)
Rathinam, Ananthanarayanan; Ramesh, Rengaswamy; Reddy, P. Subbarami; Ramaswami, Ramaswamy
Several methods for testing stability of first quadrant quarter-plane two dimensional (2-D) recursive digital filters have been suggested in 1970's and 80's. Though Jury's row and column algorithms, row and column concatenation stability tests have been considered as highly efficient mapping methods. They still fall short of accuracy as they need infinite number of steps to conclude about the exact stability of the filters and also the computational time required is enormous. In this paper, we present procedurally very simple algebraic method requiring only two steps when applied to the second order 2-D quarter - plane filter. We extend the same method to the second order Non-Symmetric Half-plane (NSHP) filters. Enough examples are given for both these types of filters as well as some lower order general recursive 2-D digital filters. We applied our method to barely stable or barely unstable filter examples available in the literature and got the same decisions thus showing that our method is accurate enough.
Experimental study of pancreaticojejunostomy completed using anastomotic chains
NASA Astrophysics Data System (ADS)
Pan, Wei-Dong; Xu, Rui-Yun; Li, Nan; Fang, He-Ping; Pan, Cu-Zhi; Tang, Zhao-Feng
2010-07-01
The most difficult, time-consuming, and complication-prone step in pancreaticoduodenectomy is the pancreaticojejunostomy step. The largest disadvantage of this kind of anastomosis is the high incidence of postoperative anastomotic leakage. Once pancreatic leakage occurs, the patient death rate can be very high. The aim of this study was to design a pancreaticojejunostomy procedure using anastomotic chains, which results in the cut end of the jejunum being attached to the pancreatic stump without suturing, and to evaluate the safety and efficacy of this procedure in domestic pigs. The pancreaticojejunal anastomotic chains had the following structures: the chains consisted of two braceletlike chains made of titanium, named chain A and chain B. The function of chain A was to attach the free jejunal end onto the pancreatic stump, whereas the function of chain B was to tighten the contact between the jejunal wall and the surface of the pancreatic stump to eliminate gaps between the two structures and ensure tightness that is sufficient to guarantee that there is no leakage of jejunal fluid or pancreatic juice. The following procedure was used to assess the safety and efficacy of the procedure: pancreaticojejunostomies were performed on ten domestic pigs using anastomotic chains. The time required to complete the pancreaticojejunal anastomoses, the pressure tolerance of the pancreaticojejunal anastomoses, the pig death rate, and the histopathological examinations of the pancreaticojejunostomy tissues were recorded. The average time required to complete the pancreaticojejunal anastomosis procedure was 13±2 min. The observed tolerance pressure of the pancreaticojejunal anastomoses was more than 90 mm H2O. All ten domestic pigs that underwent operations were still alive four weeks after the operations. Pathological examinations showed that the anastomotic surfaces were completely healed, and the pancreatic cutting surfaces were primarily epithelialized. In conclusion, the use of anastomotic chains in pancreaticojejunostomy procedures results in a decrease in or elimination of pancreatic leakage. In addition, the procedure is simple to perform, is not time-intensive, and appears to be safe in a pig model.
Gao, Le; Li, Jian; Wu, Yandan; Yu, Miaohao; Chen, Tian; Shi, Zhixiong; Zhou, Xianqing; Sun, Zhiwei
2016-11-01
Two simple and efficient pretreatment procedures have been developed for the simultaneous extraction and cleanup of six novel brominated flame retardants (NBFRs) and eight common polybrominated diphenyl ethers (PBDEs) in human serum. The first sample pretreatment procedure was a quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based approach. An acetone/hexane mixture was employed to isolate the lipid and analytes from the serum with a combination of MgSO 4 and NaCl, followed by a dispersive solid-phase extraction (d-SPE) step using C18 particles as a sorbent. The second sample pretreatment procedure was based on solid-phase extraction. The sample extraction and cleanup were conducted directly on an Oasis HLB SPE column using 5 % aqueous isopropanol, concentrated sulfuric acid, and 10 % aqueous methanol, followed by elution with dichloromethane. The NBFRs and PBDEs were then detected using gas chromatography-negative chemical ionization mass spectrometry (GC-NCI MS). The methods were assessed for repeatability, accuracy, selectivity, limits of detection (LODs), and linearity. The results of spike recovery experiments in fetal bovine serum showed that average recoveries ranged from 77.9 % to 128.8 % with relative standard deviations (RSDs) from 0.73 % to 12.37 % for most of the analytes. The LODs for the analytes in fetal bovine serum ranged from 0.3 to 50.8 pg/mL except for decabromodiphenyl ethane. The proposed method was successfully applied to the determination of the 14 brominated flame retardants in human serum. The two pretreatment procedures described here are simple, accurate, and precise, and are suitable for the routine analysis of human serum. Graphical Abstract Workflow of a QuEChERS-based approach (top) and an SPE-based approach (bottom) for the detection of PBDEs and NBFRs in serum.
Local anesthesia for inguinal hernia repair step-by-step procedure.
Amid, P K; Shulman, A G; Lichtenstein, I L
1994-01-01
OBJECTIVE. The authors introduce a simple six-step infiltration technique that results in satisfactory local anesthesia and prolonged postoperative analgesia, requiring a maximum of 30 to 40 mL of local anesthetic solution. SUMMARY BACKGROUND DATA. For the last 20 years, more than 12,000 groin hernia repairs have been performed under local anesthesia at the Lichtenstein Hernia Institute. Initially, field block was the mean of achieving local anesthesia. During the last 5 years, a simple infiltration technique has been used because the field block was more time consuming and required larger volume of the local anesthetic solution. Furthermore, because of the blind nature of the procedure, it did not always result in satisfactory anesthesia and, at times, accidental needle puncture of the ilioinguinal nerve resulted in prolonged postoperative pain, burning, or electric shock sensation within the field of the ilioinguinal nerve innervation. METHODS. More than 12,000 patients underwent operations in a private practice setting in general hospitals. RESULTS. For 2 decades, more than 12,000 adult patients with reducible groin hernias satisfactorily underwent operations under local anesthesia without complications. CONCLUSIONS. The preferred choice of anesthesia for all reducible adult inguinal hernia repair is local. It is safe, simple, effective, and economical, without postanesthesia side effects. Furthermore, local anesthesia administered before the incision produces longer postoperative analgesia because local infiltration, theoretically, inhibits build-up of local nociceptive molecules and, therefore, there is better pain control in the postoperative period. Images Figure 1. Figure 2. PMID:7986138
Direct conversion of rheological compliance measurements into storage and loss moduli.
Evans, R M L; Tassieri, Manlio; Auhl, Dietmar; Waigh, Thomas A
2009-07-01
We remove the need for Laplace/inverse-Laplace transformations of experimental data, by presenting a direct and straightforward mathematical procedure for obtaining frequency-dependent storage and loss moduli [G'(omega) and G''(omega), respectively], from time-dependent experimental measurements. The procedure is applicable to ordinary rheological creep (stress-step) measurements, as well as all microrheological techniques, whether they access a Brownian mean-square displacement, or a forced compliance. Data can be substituted directly into our simple formula, thus eliminating traditional fitting and smoothing procedures that disguise relevant experimental noise.
Direct conversion of rheological compliance measurements into storage and loss moduli
NASA Astrophysics Data System (ADS)
Evans, R. M. L.; Tassieri, Manlio; Auhl, Dietmar; Waigh, Thomas A.
2009-07-01
We remove the need for Laplace/inverse-Laplace transformations of experimental data, by presenting a direct and straightforward mathematical procedure for obtaining frequency-dependent storage and loss moduli [ G'(ω) and G″(ω) , respectively], from time-dependent experimental measurements. The procedure is applicable to ordinary rheological creep (stress-step) measurements, as well as all microrheological techniques, whether they access a Brownian mean-square displacement, or a forced compliance. Data can be substituted directly into our simple formula, thus eliminating traditional fitting and smoothing procedures that disguise relevant experimental noise.
NASA Technical Reports Server (NTRS)
Englert, G. W.
1971-01-01
A model of the random walk is formulated to allow a simple computing procedure to replace the difficult problem of solution of the Fokker-Planck equation. The step sizes and probabilities of taking steps in the various directions are expressed in terms of Fokker-Planck coefficients. Application is made to many particle systems with Coulomb interactions. The relaxation of a highly peaked velocity distribution of particles to equilibrium conditions is illustrated.
Pal, Jayanta K; Berwal, Sunil K; Soni, Rupali N
2012-01-01
A simple method for staining of proteins simultaneously on sodium dodecyl sulfate (SDS) polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis is described. A 5% solution of Alta, a commercially available cosmetic preparation, is added in the upper tank buffer during electrophoresis. On completion of electrophoresis, the gel is washed in distilled water and viewed on a white light plate and a transilluminator to photograph the protein profiles. The gel is processed for western blot transfer of proteins onto a nitrocellulose membrane, and upon completion, the protein profiles on the membrane are viewed and photographed as stated above. The membrane can then be processed for immunostaining as per the standard procedure. Thus, the staining procedure using Alta is simple, rapid (without any need of destaining), and cost-effective.
ERIC Educational Resources Information Center
de Dios, Miguel; Salgueirino, Veronica; Perez-Lorenzo, Moises; Correa-Duarte, Miguel A.
2012-01-01
An experiment is described to introduce advanced undergraduate students to an exciting area of nanotechnology that incorporates nanoparticles onto carbon nanotubes to produce systems that have valuable technological applications. The synthesis of such material has been easily achieved through a simple three-step procedure. Students explore…
A Simple Endpoint Assay for Starch-Degrading Enzymes.
ERIC Educational Resources Information Center
Kroen, William K.
1998-01-01
Since many of the important energy-transferring pathways involve synthesis or degradation of biological macromolecules, observations of the enzymes responsible for starch breakdown provide a useful case study. Provides a short, one-step assay for the enzymes amylase and amyloglucosidase. Topics covered include goals, preparation, assay procedure,…
Regression Analysis of a Disease Onset Distribution Using Diagnosis Data
Young, Jessica G.; Jewell, Nicholas P.; Samuels, Steven J.
2008-01-01
Summary We consider methods for estimating the effect of a covariate on a disease onset distribution when the observed data structure consists of right-censored data on diagnosis times and current status data on onset times amongst individuals who have not yet been diagnosed. Dunson and Baird (2001, Biometrics 57, 306–403) approached this problem using maximum likelihood, under the assumption that the ratio of the diagnosis and onset distributions is monotonic nondecreasing. As an alternative, we propose a two-step estimator, an extension of the approach of van der Laan, Jewell, and Petersen (1997, Biometrika 84, 539–554) in the single sample setting, which is computationally much simpler and requires no assumptions on this ratio. A simulation study is performed comparing estimates obtained from these two approaches, as well as that from a standard current status analysis that ignores diagnosis data. Results indicate that the Dunson and Baird estimator outperforms the two-step estimator when the monotonicity assumption holds, but the reverse is true when the assumption fails. The simple current status estimator loses only a small amount of precision in comparison to the two-step procedure but requires monitoring time information for all individuals. In the data that motivated this work, a study of uterine fibroids and chemical exposure to dioxin, the monotonicity assumption is seen to fail. Here, the two-step and current status estimators both show no significant association between the level of dioxin exposure and the hazard for onset of uterine fibroids; the two-step estimator of the relative hazard associated with increasing levels of exposure has the least estimated variance amongst the three estimators considered. PMID:17680832
Mechanochemical synthesis and intercalation of Ca(II)Fe(III)-layered double hydroxides
NASA Astrophysics Data System (ADS)
Ferencz, Zs.; Szabados, M.; Varga, G.; Csendes, Z.; Kukovecz, Á.; Kónya, Z.; Carlson, S.; Sipos, P.; Pálinkó, I.
2016-01-01
A mechanochemical method (grinding the components without added water - dry grinding, followed by further grinding in the presence of minute amount of water or NaOH solution - wet grinding) was used in this work for the preparation and intercalation of CaFe-layered double hydroxides (LDHs). Both the pristine LDHs and the amino acid anion (cystinate and tyrosinate) intercalated varieties were prepared by the two-step grinding procedure in a mixer mill. By systematically changing the conditions of the preparation method, a set of parameters could be determined, which led to the formation of close to phase-pure LDH. The optimisation procedure was also applied for the intercalation processes of the amino acid anions. The resulting materials were structurally characterised by a range of methods (X-ray diffractometry, scanning electron microscopy, energy dispersive analysis, thermogravimetry, X-ray absorption and infra-red spectroscopies). It was proven that this simple mechanochemical procedure was able to produce complex organic-inorganic nanocomposites: LDHs intercalated with amino acid anions.
Output-Sensitive Construction of Reeb Graphs.
Doraiswamy, H; Natarajan, V
2012-01-01
The Reeb graph of a scalar function represents the evolution of the topology of its level sets. This paper describes a near-optimal output-sensitive algorithm for computing the Reeb graph of scalar functions defined over manifolds or non-manifolds in any dimension. Key to the simplicity and efficiency of the algorithm is an alternate definition of the Reeb graph that considers equivalence classes of level sets instead of individual level sets. The algorithm works in two steps. The first step locates all critical points of the function in the domain. Critical points correspond to nodes in the Reeb graph. Arcs connecting the nodes are computed in the second step by a simple search procedure that works on a small subset of the domain that corresponds to a pair of critical points. The paper also describes a scheme for controlled simplification of the Reeb graph and two different graph layout schemes that help in the effective presentation of Reeb graphs for visual analysis of scalar fields. Finally, the Reeb graph is employed in four different applications-surface segmentation, spatially-aware transfer function design, visualization of interval volumes, and interactive exploration of time-varying data.
Hsieh, Hong-Po; Ko, Fan-Hua; Sung, Kung-Bin
2018-04-20
An iterative curve fitting method has been applied in both simulation [J. Biomed. Opt.17, 107003 (2012)JBOPFO1083-366810.1117/1.JBO.17.10.107003] and phantom [J. Biomed. Opt.19, 077002 (2014)JBOPFO1083-366810.1117/1.JBO.19.7.077002] studies to accurately extract optical properties and the top layer thickness of a two-layered superficial tissue model from diffuse reflectance spectroscopy (DRS) data. This paper describes a hybrid two-step parameter estimation procedure to address two main issues of the previous method, including (1) high computational intensity and (2) converging to local minima. The parameter estimation procedure contained a novel initial estimation step to obtain an initial guess, which was used by a subsequent iterative fitting step to optimize the parameter estimation. A lookup table was used in both steps to quickly obtain reflectance spectra and reduce computational intensity. On simulated DRS data, the proposed parameter estimation procedure achieved high estimation accuracy and a 95% reduction of computational time compared to previous studies. Furthermore, the proposed initial estimation step led to better convergence of the following fitting step. Strategies used in the proposed procedure could benefit both the modeling and experimental data processing of not only DRS but also related approaches such as near-infrared spectroscopy.
A multiple-objective optimal exploration strategy
Christakos, G.; Olea, R.A.
1988-01-01
Exploration for natural resources is accomplished through partial sampling of extensive domains. Such imperfect knowledge is subject to sampling error. Complex systems of equations resulting from modelling based on the theory of correlated random fields are reduced to simple analytical expressions providing global indices of estimation variance. The indices are utilized by multiple objective decision criteria to find the best sampling strategies. The approach is not limited by geometric nature of the sampling, covers a wide range in spatial continuity and leads to a step-by-step procedure. ?? 1988.
NASA Technical Reports Server (NTRS)
McGinness, Kathleen E.; Wright, Martin C.; Joyce, Gerald F.
2002-01-01
Variants of the class I ligase ribozyme, which catalyzes joining of the 3' end of a template bound oligonucleotide to its own 5' end, have been made to evolve in a continuous manner by a simple serial transfer procedure that can be carried out indefinitely. This process was expanded to allow the evolution of ribozymes that catalyze three successive nucleotidyl addition reactions, two template-directed mononucleotide additions followed by RNA ligation. During the development of this behavior, a population of ribozymes was maintained against an overall dilution of more than 10(exp 406). The resulting ribozymes were capable of catalyzing the three-step reaction pathway, with nucleotide addition occurring in either a 5' yieldig 3' or a 3' yielding 5' direction. This purely chemical system provides a functional model of a multi-step reaction pathway that is undergoing Darwinian evolution.
2012-01-01
Background Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. Results This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. Conclusions The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in paint samples. PMID:23050842
Lluveras-Tenorio, Anna; Mazurek, Joy; Restivo, Annalaura; Colombini, Maria Perla; Bonaduce, Ilaria
2012-10-10
Saccharide materials have been used for centuries as binding media, to paint, write and illuminate manuscripts and to apply metallic leaf decorations. Although the technical literature often reports on the use of plant gums as binders, actually several other saccharide materials can be encountered in paint samples, not only as major binders, but also as additives. In the literature, there are a variety of analytical procedures that utilize GC-MS to characterize saccharide materials in paint samples, however the chromatographic profiles are often extremely different and it is impossible to compare them and reliably identify the paint binder. This paper presents a comparison between two different analytical procedures based on GC-MS for the analysis of saccharide materials in works-of-art. The research presented here evaluates the influence of the analytical procedure used, and how it impacts the sugar profiles obtained from the analysis of paint samples that contain saccharide materials. The procedures have been developed, optimised and systematically used to characterise plant gums at the Getty Conservation Institute in Los Angeles, USA (GCI) and the Department of Chemistry and Industrial Chemistry of the University of Pisa, Italy (DCCI). The main steps of the analytical procedures and their optimisation are discussed. The results presented highlight that the two methods give comparable sugar profiles, whether the samples analysed are simple raw materials, pigmented and unpigmented paint replicas, or paint samples collected from hundreds of centuries old polychrome art objects. A common database of sugar profiles of reference materials commonly found in paint samples was thus compiled. The database presents data also from those materials that only contain a minor saccharide fraction. This database highlights how many sources of saccharides can be found in a paint sample, representing an important step forward in the problem of identifying polysaccharide binders in paint samples.
Cervera, R P; Garcia-Ximénez, F
2003-10-01
The purpose of this study was to test the effectiveness of one two-step (A) and two one-step (B1 and B2) vitrification procedures on denuded expanded or hatching rabbit blastocysts held in standard sealed plastic straws as a possible model for human blastocysts. The effect of blastocyst size was also studied on the basis of three size categories (I: diameter <200 micro m; II: diameter 200-299 micro m; III: diameter >/==" BORDER="0">300 micro m). Rabbit expanded or hatching blastocysts were vitrified at day 4 or 5. Before vitrification, the zona pellucida was removed using acidic phosphate buffered saline. For the two-step procedure, prior to vitrification, blastocysts were pre- equilibrated in a solution containing 10% dimethyl sulphoxide (DMSO) and 10% ethylene glycol (EG) for 1 min. Different final vitrification solutions were compared: 20% DMSO and 20% EG with (A and B1) or without (B2) 0.5 mol/l sucrose. Of 198 vitrified blastocysts, 181 (91%) survived, regardless of the vitrification procedure applied. Vitrification procedure A showed significantly higher re-expansion (88%), attachment (86%) and trophectoderm outgrowth (80%) rates than the two one-step vitrification procedures, B1 and B2 (46 and 21%, 20 and 33%, and 18 and 23%, respectively). After warming, blastocysts of greater size (II and III) showed significantly higher attachment (54 and 64%) and trophectoderm outgrowth (44 and 58%) rates than smaller blastocysts (I, attachment: 29%; trophectoderm outgrowth: 25%). These result demonstrate that denuded expanded or hatching rabbit blastocysts of greater size can be satisfactorily vitrified by use of a two-step procedure. The similarity of vitrification solutions used in humans could make it feasible to test such a procedure on human denuded blastocysts of different sizes.
NASA Technical Reports Server (NTRS)
Manson, S. S.; Halford, G. R.
1980-01-01
Simple procedures are presented for treating cumulative fatigue damage under complex loading history using either the damage curve concept or the double linear damage rule. A single equation is provided for use with the damage curve approach; each loading event providing a fraction of damage until failure is presumed to occur when the damage sum becomes unity. For the double linear damage rule, analytical expressions are provided for determining the two phases of life. The procedure involves two steps, each similar to the conventional application of the commonly used linear damage rule. When the sum of cycle ratios based on phase 1 lives reaches unity, phase 1 is presumed complete, and further loadings are summed as cycle ratios on phase 2 lives. When the phase 2 sum reaches unity, failure is presumed to occur. No other physical properties or material constants than those normally used in a conventional linear damage rule analysis are required for application of either of the two cumulative damage methods described. Illustrations and comparisons of both methods are discussed.
NASA Technical Reports Server (NTRS)
Manson, S. S.; Halford, G. R.
1981-01-01
Simple procedures are given for treating cumulative fatigue damage under complex loading history using either the damage curve concept or the double linear damage rule. A single equation is given for use with the damage curve approach; each loading event providing a fraction of damage until failure is presumed to occur when the damage sum becomes unity. For the double linear damage rule, analytical expressions are given for determining the two phases of life. The procedure comprises two steps, each similar to the conventional application of the commonly used linear damage rule. Once the sum of cycle ratios based on Phase I lives reaches unity, Phase I is presumed complete, and further loadings are summed as cycle ratios based on Phase II lives. When the Phase II sum attains unity, failure is presumed to occur. It is noted that no physical properties or material constants other than those normally used in a conventional linear damage rule analysis are required for application of either of the two cumulative damage methods described. Illustrations and comparisons are discussed for both methods.
Steepest descent method implementation on unconstrained optimization problem using C++ program
NASA Astrophysics Data System (ADS)
Napitupulu, H.; Sukono; Mohd, I. Bin; Hidayat, Y.; Supian, S.
2018-03-01
Steepest Descent is known as the simplest gradient method. Recently, many researches are done to obtain the appropriate step size in order to reduce the objective function value progressively. In this paper, the properties of steepest descent method from literatures are reviewed together with advantages and disadvantages of each step size procedure. The development of steepest descent method due to its step size procedure is discussed. In order to test the performance of each step size, we run a steepest descent procedure in C++ program. We implemented it to unconstrained optimization test problem with two variables, then we compare the numerical results of each step size procedure. Based on the numerical experiment, we conclude the general computational features and weaknesses of each procedure in each case of problem.
Preparation of isotopic molybdenum foils utilizing small quantities of material
NASA Astrophysics Data System (ADS)
Lipski, A. R.; Lee, L. L.; Liang, J. F.; Mahon, J. C.
1993-09-01
A simple method utilizing a small amount of isotopic material for production of molybdenum foils is discussed. An e-gun is used in the procedure. The Mo powder undergoes reduction-sintering and melting-solidifying steps leading to the creation of a metallic droplet suitable for further cold rolling or vacuum deposition.
Using Response Interruption and Redirection to Reduce Vocal Stereotypy
ERIC Educational Resources Information Center
Sheehey, Patricia H.; Wells, Jenny C.
2018-01-01
Response interruption and redirection, commonly referred to as RIR, is an evidence-based intervention that has been demonstrated to quickly reduce moderate to high levels of vocal stereotypy in children with autism spectrum disorder. The RIR intervention is a simple, three-step procedure that can be embedded in classroom instruction with minimal…
Improving the cleaning procedure to make kitchen floors less slippery.
Quirion, F; Poirier, P; Lehane, P
2008-12-01
This investigation shows that, in most cases, the floor cleaning procedure of typical restaurants could be improved, resulting in a better cleaning efficiency and a better floor friction. This simple approach could help reduce slips and falls in the workplace. Food safety officers visited ten European style restaurants in the London Borough of Bromley (UK) to identify their floor cleaning procedure in terms of the cleaning method, the concentration and type of floor cleaner and the temperature of the wash water. For all 10 restaurants visited, the cleaning method was damp mopping. Degreasers were used in three sites while neutral floor cleaners were used in seven sites. Typically, the degreasers were over diluted and the neutrals were overdosed. The wash water temperature ranged from 10 to 72 degrees C. The on-site cleaning procedures were repeated in the laboratory for the removal of olive oil from new and sealed quarry tiles, fouled and worn quarry tiles and new porcelain tiles. It is found that in 24 out of 30 cases, cleaning efficiency can be improved by simple changes in the floor cleaning procedure and that these changes result in a significant improvement of the floor friction. The nature of the improved floor cleaning procedure depends on the flooring type. New and properly sealed flooring tiles can be cleaned using damp mopping with a degreaser diluted as recommended by the manufacturer in warm or hot water (24 to 50 degrees C). But as the tiles become worn and fouled, a more aggressive floor cleaning is required such as two-step mopping with a degreaser diluted as recommended by the manufacturer in warm water (24 degrees C).
Computational Phenotyping in Psychiatry: A Worked Example
2016-01-01
Abstract Computational psychiatry is a rapidly emerging field that uses model-based quantities to infer the behavioral and neuronal abnormalities that underlie psychopathology. If successful, this approach promises key insights into (pathological) brain function as well as a more mechanistic and quantitative approach to psychiatric nosology—structuring therapeutic interventions and predicting response and relapse. The basic procedure in computational psychiatry is to build a computational model that formalizes a behavioral or neuronal process. Measured behavioral (or neuronal) responses are then used to infer the model parameters of a single subject or a group of subjects. Here, we provide an illustrative overview over this process, starting from the modeling of choice behavior in a specific task, simulating data, and then inverting that model to estimate group effects. Finally, we illustrate cross-validation to assess whether between-subject variables (e.g., diagnosis) can be recovered successfully. Our worked example uses a simple two-step maze task and a model of choice behavior based on (active) inference and Markov decision processes. The procedural steps and routines we illustrate are not restricted to a specific field of research or particular computational model but can, in principle, be applied in many domains of computational psychiatry. PMID:27517087
Computational Phenotyping in Psychiatry: A Worked Example.
Schwartenbeck, Philipp; Friston, Karl
2016-01-01
Computational psychiatry is a rapidly emerging field that uses model-based quantities to infer the behavioral and neuronal abnormalities that underlie psychopathology. If successful, this approach promises key insights into (pathological) brain function as well as a more mechanistic and quantitative approach to psychiatric nosology-structuring therapeutic interventions and predicting response and relapse. The basic procedure in computational psychiatry is to build a computational model that formalizes a behavioral or neuronal process. Measured behavioral (or neuronal) responses are then used to infer the model parameters of a single subject or a group of subjects. Here, we provide an illustrative overview over this process, starting from the modeling of choice behavior in a specific task, simulating data, and then inverting that model to estimate group effects. Finally, we illustrate cross-validation to assess whether between-subject variables (e.g., diagnosis) can be recovered successfully. Our worked example uses a simple two-step maze task and a model of choice behavior based on (active) inference and Markov decision processes. The procedural steps and routines we illustrate are not restricted to a specific field of research or particular computational model but can, in principle, be applied in many domains of computational psychiatry.
The development of a purification procedure for saxitoxin-induced protein.
Smith, D S; Kitts, D D; Fenske, B; Owen, T G; Shyng, S
1995-02-01
A simple economical procedure for purifying saxitoxin-induced protein (SIP) from crude extracts of the small shore crab, Hemigrapsus oregenesis, was developed. (NH4)2SO4 precipitation, chymotrypsin digestion, heat treatment, gel filtration and ion-exchange-chromatography procedures were evaluated in purifying SIP. An enzyme immunoassay was used to determine the SIP yield and relative purity at each step of three procedures, thus permitting an assessment of the conditions required for maximum recovery. Response surface analysis was used in an attempt to determine the optimum temperature and exposure time for the heat treatment. A 20 min incubation at 65 degrees C was confirmed by electrophoretic analysis to be the best combination of time and temperature for achieving both an acceptable yield and purity of SIP. SIP in desalted concentrate was shown to be resistant to chymotrypsin proteolysis; however, this enzyme had deleterious effects on SIP purification at later stages of the procedure. The omission of the chymotrypsin digestion, and the inclusion of gel-filtration chromatography in the final clean-up step, resulted in the purification of SIP comparable with that achieved with affinity chromatography.
Modeling Woven Polymer Matrix Composites with MAC/GMC
NASA Technical Reports Server (NTRS)
Bednarcyk, Brett A.; Arnold, Steven M. (Technical Monitor)
2000-01-01
NASA's Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) is used to predict the elastic properties of plain weave polymer matrix composites (PMCs). The traditional one step three-dimensional homogertization procedure that has been used in conjunction with MAC/GMC for modeling woven composites in the past is inaccurate due to the lack of shear coupling inherent to the model. However, by performing a two step homogenization procedure in which the woven composite repeating unit cell is homogenized independently in the through-thickness direction prior to homogenization in the plane of the weave, MAC/GMC can now accurately model woven PMCs. This two step procedure is outlined and implemented, and predictions are compared with results from the traditional one step approach and other models and experiments from the literature. Full coupling of this two step technique with MAC/ GMC will result in a widely applicable, efficient, and accurate tool for the design and analysis of woven composite materials and structures.
NASA Astrophysics Data System (ADS)
Kim, Yong-Hyun; Kim, Ki-Hyun
2015-07-01
The analysis of polycyclic aromatic hydrocarbons (PAH) in ambient air requires the tedious experimental steps of both sampling and pretreatment (e.g., extraction or clean-up). To replace pre-existing conventional methods, a simple, rapid, and novel technique was developed to measure gas-particle fractionation of PAH in ambient air based on ‘sorbent tube-thermal desorption-gas chromatograph-mass spectrometer (ST-TD-GC-MS)’. The separate collection and analysis of ambient PAHs were achieved independently by two serially connected STs. The basic quality assurance confirmed good linearity, precision, and high sensitivity to eliminate the need for complicated pretreatment procedures with the detection limit (16 PAHs: 13.1 ± 7.04 pg). The analysis of real ambient PAH samples showed a clear fractionation between gas (two-three ringed PAHs) and particulate phases (five-six ringed PAHs). In contrast, for intermediate (four ringed) PAHs (fluoranthene, pyrene, benz[a]anthracene, and chrysene), a highly systematic/gradual fractionation was established. It thus suggests a promising role of ST-TD-GC-MS as measurement system in acquiring a reliable database of airborne PAH.
2012-01-01
Naturally occurring native peptides provide important information about physiological states of an organism and its changes in disease conditions but protocols and methods for assessing their abundance are not well-developed. In this paper, we describe a simple procedure for the quantification of non-tryptic peptides in body fluids. The workflow includes an enrichment step followed by two-dimensional fractionation of native peptides and MS/MS data management facilitating the design and validation of LC- MRM MS assays. The added value of the workflow is demonstrated in the development of a triplex LC-MRM MS assay used for quantification of peptides potentially associated with the progression of liver disease to hepatocellular carcinoma. PMID:22304756
Registration of Heat Capacity Mapping Mission day and night images
NASA Technical Reports Server (NTRS)
Watson, K.; Hummer-Miller, S.; Sawatzky, D. L. (Principal Investigator)
1982-01-01
Neither iterative registration, using drainage intersection maps for control, nor cross correlation techniques were satisfactory in registering day and night HCMM imagery. A procedure was developed which registers the image pairs by selecting control points and mapping the night thermal image to the daytime thermal and reflectance images using an affine transformation on a 1300 by 1100 pixel image. The resulting image registration is accurate to better than two pixels (RMS) and does not exhibit the significant misregistration that was noted in the temperature-difference and thermal-inertia products supplied by NASA. The affine transformation was determined using simple matrix arithmetic, a step that can be performed rapidly on a minicomputer.
Jenkins, T C; Thies, E J; Mosley, E E
2001-05-01
Two direct methylation procedures often used for the analysis of total fatty acids in biological samples were evaluated for their application to samples containing fatty amides. Methylation of 5 mg of oleamide (cis-9-octadecenamide) in a one-step (methanolic HCl for 2 h at 70 degrees C) or a two-step (sodium methoxide for 10 min at 50 degrees C followed by methanolic HCl for 10 min at 80 degrees C) procedure gave 59 and 16% conversions of oleamide to oleic acid, respectively. Oleic acid recovery from oleamide was increased to 100% when the incubation in methanolic HCl was lengthened to 16 h and increased to 103% when the incubation in methoxide was modified to 24 h at 100 degrees C. However, conversion of oleamide to oleic acid in an animal feed sample was incomplete for the modified (24 h) two-step procedure but complete for the modified (16 h) one-step procedure. Unsaturated fatty amides in feed and digesta samples can be converted to fatty acid methyl esters by incubation in methanolic HCl if the time of exposure to the acid catalyst is extended from 2 to 16 h.
USDA-ARS?s Scientific Manuscript database
The economic and environmentally friendly flame retardant compound, tetramethyl (6-chloro-1,3,5-triazine-2,4-diyl)bis(oxy)bis (methylene)diphosphonate (FR-1) was synthesized by a simple 2 step procedure from dimethyl phosphate, and its chemical structure was characterized by 1H, 13C, and 31P nuclea...
NASA Astrophysics Data System (ADS)
Metusala, D.
2017-07-01
This alternative method provides a simple and faster procedure for preparing cross-sections of leaves and roots in herbaceous plants, especially for living specimens of orchids (Orchidaceae). This method used a clamp-on hand sliding microtome to make cross-sections of leaves and roots, with sections preserved inside the microtubes containing preservation liquid. This preservation technique allowed the sections to be restained and to be used for further usage in future. This method was more practical than the paraffin embedding method because it does not need the additional steps of paraffin embedding and deparaffinization. It may also provide better cross-section results than free-hand sectioning method. The procedure is very feasible and is recommended for use in plant anatomy observation.
Atkins, Tonya M; Louie, Angelique Y; Kauzlarich, Susan M
2012-07-27
Silicon nanoparticles can be considered a green material, especially when prepared via a microwave-assisted method without the use of highly reactive reducing agents or hydrofluoric acid. A simple solution synthesis of hydrogen-terminated Si- and Mn-doped Si nanoparticles via microwave-assisted synthesis is demonstrated. The reaction of the Zintl salt, Na(4)Si(4), or Mn-doped Na(4)Si(4), Na(4)Si(4(Mn)), with ammonium bromide, NH(4)Br, produces small dispersible nanoparticles along with larger particles that precipitate. Allylamine and 1-amino-10-undecene were reacted with the hydrogen-terminated Si nanoparticles to provide water solubility and stability. A one-pot, single-reaction process and a one-pot, two-step reaction process were investigated. Details of the microwave-assisted process are provided, with the optimal synthesis being the one-pot, two-step reaction procedure and a total time of about 15 min. The nanoparticles were characterized by transmission electron microscopy (TEM), x-ray diffraction, and fluorescence spectroscopies. The microwave-assisted method reliably produces a narrow size distribution of Si nanoparticles in solution.
A simple way to prepare Pd/Fe₃O₄/polypyrrole hollow capsules and their applications in catalysis.
Yao, Tongjie; Zuo, Quan; Wang, Hao; Wu, Jie; Xin, Baifu; Cui, Fang; Cui, Tieyu
2015-07-15
Preparation of catalysts with good catalytic activity and high stability, together with magnetic separation property, in a simple way is highly desirable. In this paper, we reported a novel strategy to construct magnetic recyclable hollow capsules with Pd and Fe3O4 nanoparticles embedded in polypyrrole (PPy) shell via only two steps: first, synthesization of Pd nanoparticles, preparation of Fe3O4 nanoparticles, and formation of PPy shell were finished in one-step on the surface of polystyrene (PS) nanospheres; then, the PS core was selectively removed by tetrahydrofuran. The Pd/Fe3O4/PPy hollow capsules exhibited good catalytic property in reduction of 4-nitrophenol with NaBH4 as reducing agent, and the reaction rate constants were calculated through pseudo-first-order reaction equation. Due to incorporation of Fe3O4 nanoparticles, the catalysts could be quickly separated from the reaction solution by magnet and reused without obvious catalytic loss. Besides catalytic property and reusability, their stability was also examined by HNO3 etching experiment. Compared with bare Pd and Fe3O4 nanoparticles, the stability of both Pd and Fe3O4 nanoparticles in hollow capsules was largely improved owing to the protection of PPy shell. The good catalytic performance, ease of separation, high stability and especially a simple preparation procedure, made Pd/Fe3O4/PPy hollow capsules highly promising candidates for diverse applications. Copyright © 2015 Elsevier Inc. All rights reserved.
Ali, Ghafar; Ahmad, Maqsood; Akhter, Javed Iqbal; Maqbool, Muhammad; Cho, Sung Oh
2010-08-01
A simple approach for the growth of long-range highly ordered nanoporous anodic alumina film in H(2)SO(4) electrolyte through a single step anodization without any additional pre-anodizing procedure is reported. Free-standing porous anodic alumina film of 180 microm thickness with through hole morphology was obtained. A simple and single step process was used for the detachment of alumina from aluminum substrate. The effect of anodizing conditions, such as anodizing voltage and time on the pore diameter and pore ordering is discussed. The metal/oxide and oxide/electrolyte interfaces were examined by high resolution scanning transmission electron microscope. The arrangement of pores on metal/oxide interface was well ordered with smaller diameters than that of the oxide/electrolyte interface. The inter-pore distance was larger in metal/oxide interface as compared to the oxide/electrolyte interface. The size of the ordered domain was found to depend strongly upon anodizing voltage and time. (c) 2010 Elsevier Ltd. All rights reserved.
Accurate Monotonicity - Preserving Schemes With Runge-Kutta Time Stepping
NASA Technical Reports Server (NTRS)
Suresh, A.; Huynh, H. T.
1997-01-01
A new class of high-order monotonicity-preserving schemes for the numerical solution of conservation laws is presented. The interface value in these schemes is obtained by limiting a higher-order polynominal reconstruction. The limiting is designed to preserve accuracy near extrema and to work well with Runge-Kutta time stepping. Computational efficiency is enhanced by a simple test that determines whether the limiting procedure is needed. For linear advection in one dimension, these schemes are shown as well as the Euler equations also confirm their high accuracy, good shock resolution, and computational efficiency.
NASA Astrophysics Data System (ADS)
Gassara, H.; El Hajjaji, A.; Chaabane, M.
2017-07-01
This paper investigates the problem of observer-based control for two classes of polynomial fuzzy systems with time-varying delay. The first class concerns a special case where the polynomial matrices do not depend on the estimated state variables. The second one is the general case where the polynomial matrices could depend on unmeasurable system states that will be estimated. For the last case, two design procedures are proposed. The first one gives the polynomial fuzzy controller and observer gains in two steps. In the second procedure, the designed gains are obtained using a single-step approach to overcome the drawback of a two-step procedure. The obtained conditions are presented in terms of sum of squares (SOS) which can be solved via the SOSTOOLS and a semi-definite program solver. Illustrative examples show the validity and applicability of the proposed results.
NASA Astrophysics Data System (ADS)
Deyhle, Hans; Schmidli, Fredy; Krastl, Gabriel; Müller, Bert
2010-09-01
Direct composite fillings belong to widespread tooth restoration techniques in dental medicine. The procedure consists of successive steps, which include etching of the prepared tooth surface, bonding and placement of composite in incrementally built up layers. Durability and lifespan of the composite inlays strongly depend on the accurate completion of the individual steps to be also realized by students in dental medicine. Improper handling or nonconformity in the bonding procedure often lead to air enclosures (bubbles) as well as to significant gaps between the composite layers or at the margins of the restoration. Traditionally one analyzes the quality of the restoration cutting the tooth in an arbitrarily selected plane and inspecting this plane by conventional optical microscopy. Although the precision of this established method is satisfactory, it is restricted to the selected two-dimensional plane. Rather simple micro computed tomography (μCT) systems, such as SkyScan 1174™, allows for the non-destructive three-dimensional imaging of restored teeth ex vivo and virtually cutting the tomographic data in any desired direction, offering a powerful tool for inspection of the restored tooth with micrometer resolution before cutting and thus also to select a two-dimensional plane with potential defects. In order to study the influence of the individual steps on the resulted tooth restoration, direct composite fillings were placed in mod cavities of extracted teeth. After etching, an adhesive was applied in half of the specimens. From the tomographic datasets, it becomes clear that gaps occur more frequently when bonding is omitted. The visualization of air enclosures offers to determine the probability to find a micrometer-sized defect using an arbitrarily selected cutting plane for inspection.
Preparation and characterization of silica xerogels as carriers for drugs.
Czarnobaj, K
2008-11-01
The aim of the present study was to utilize the sol-gel method to synthesize different forms of xerogel matrices for drugs and to investigate how the synthesis conditions and solubility of drugs influence the change of the profile of drug release and the structure of the matrices. Silica xerogels doped with drugs were prepared by the sol-gel method from a hydrolyzed tetraethoxysilane (TEOS) solution containing two model compounds: diclofenac diethylamine, (DD)--a water-soluble drug or ibuprofen, (IB)--a water insoluble drug. Two procedures were used for the synthesis of sol-gel derived materials: one-step procedure (the sol-gel reaction was carried out under acidic or basic conditions) and the two-step procedure (first, hydrolysis of TEOS was carried out under acidic conditions, and then condensation of silanol groups was carried out under basic conditions) in order to obtain samples with altered microstructures. In vitro release studies of drugs revealed a similar release profile in two steps: an initial diffusion-controlled release followed by a slower release rate. In all the cases studied, the released amount of DD was higher and the released time was shorter compared with IB for the same type of matrices. The released amount of drugs from two-step prepared xerogels was always lower than that from one-step base-catalyzed xerogels. One-step acid-catalyzed xerogels proved unsuitable as the carriers for the examined drugs.
A Simple Workstation for the Conservation of Library Materials.
ERIC Educational Resources Information Center
Conservation Correspondence, 1984
1984-01-01
The first step in designing a work station that is appropriate for both the maintenance and repair of library materials is to determine procedures likely to be necessary based on the nature of the collection and the type of use it receives. Necessary equipment includes a work station with a bench and storage space (an illustration and a list of…
Prevalidation in pharmaceutical analysis. Part I. Fundamentals and critical discussion.
Grdinić, Vladimir; Vuković, Jadranka
2004-05-28
A complete prevalidation, as a basic prevalidation strategy for quality control and standardization of analytical procedure was inaugurated. Fast and simple, the prevalidation methodology based on mathematical/statistical evaluation of a reduced number of experiments (N < or = 24) was elaborated and guidelines as well as algorithms were given in detail. This strategy has been produced for the pharmaceutical applications and dedicated to the preliminary evaluation of analytical methods where linear calibration model, which is very often occurred in practice, could be the most appropriate to fit experimental data. The requirements presented in this paper should therefore help the analyst to design and perform the minimum number of prevalidation experiments needed to obtain all the required information to evaluate and demonstrate the reliability of its analytical procedure. In complete prevalidation process, characterization of analytical groups, checking of two limiting groups, testing of data homogeneity, establishment of analytical functions, recognition of outliers, evaluation of limiting values and extraction of prevalidation parameters were included. Moreover, system of diagnosis for particular prevalidation step was suggested. As an illustrative example for demonstration of feasibility of prevalidation methodology, among great number of analytical procedures, Vis-spectrophotometric procedure for determination of tannins with Folin-Ciocalteu's phenol reagent was selected. Favourable metrological characteristics of this analytical procedure, as prevalidation figures of merit, recognized the metrological procedure as a valuable concept in preliminary evaluation of quality of analytical procedures.
NASA Astrophysics Data System (ADS)
Jensen, Ashley W.; O'Brien, Brian A.
2001-07-01
A one-step procedure for the preparation of tris(1,1,1-trifluoro-2,4-pentanedionato)cobalt(III) from hydrated cobalt(II) carbonate and 10% hydrogen peroxide, in which tert-butyl alcohol is used as a component of the solvent, is described. The procedure is short, simple, and less hazardous than procedures reported in the literature, and the starting materials are readily available and inexpensive. The product is a mixture of mer and fac isomers that can be separated by silica gel chromatography with toluene as the eluent. Thin-layer chromatography is used to obtain a collective class sample of each isomer for 1H, 13C, and 19F NMR analysis. The NMR analyses clearly illustrate the threefold rotational symmetry of the fac isomer and the lack of symmetry of the mer isomer. Detailed NMR data are provided for each isomer.
Multipurpose silicon photonics signal processor core.
Pérez, Daniel; Gasulla, Ivana; Crudgington, Lee; Thomson, David J; Khokhar, Ali Z; Li, Ke; Cao, Wei; Mashanovich, Goran Z; Capmany, José
2017-09-21
Integrated photonics changes the scaling laws of information and communication systems offering architectural choices that combine photonics with electronics to optimize performance, power, footprint, and cost. Application-specific photonic integrated circuits, where particular circuits/chips are designed to optimally perform particular functionalities, require a considerable number of design and fabrication iterations leading to long development times. A different approach inspired by electronic Field Programmable Gate Arrays is the programmable photonic processor, where a common hardware implemented by a two-dimensional photonic waveguide mesh realizes different functionalities through programming. Here, we report the demonstration of such reconfigurable waveguide mesh in silicon. We demonstrate over 20 different functionalities with a simple seven hexagonal cell structure, which can be applied to different fields including communications, chemical and biomedical sensing, signal processing, multiprocessor networks, and quantum information systems. Our work is an important step toward this paradigm.Integrated optical circuits today are typically designed for a few special functionalities and require complex design and development procedures. Here, the authors demonstrate a reconfigurable but simple silicon waveguide mesh with different functionalities.
Wu, Guo-Lan; Zhou, Hui-Li; Shentu, Jian-Zhong; He, Qiao-Jun; Yang, Bo
2008-12-15
A simple, sensitive and rapid LC/MS/MS method was developed for the quantification of lansoprazole in human plasma. After a simple sample preparation procedure by one-step protein precipitation with acetonitrile, lansoprazole and the internal standard bicalutamide were chromatographed on a Zorbax SB-C(18) (3.0 mm x 150 mm, 3.5 microm, Agilent) column with the mobile phase consisted of methanol-water (70:30, v/v, containing 5 mM ammonium formate, pH was adjusted to 7.85 by 1% ammonia solution). Detection was performed on a triple quadrupole tandem mass spectrometry by multiple reaction monitoring (MRM) mode via negative eletrospray ionization source (ESI(-)). The lower limit of quantification was 5.5 ng/mL, and the assay exhibited a linear range of 5.5-2200.0 ng/mL. The validated method was successfully applied to investigate the bioequivalence between two kinds of preparation (test vs. reference product) in twenty-eight healthy male Chinese volunteers.
"Split Cast Mounting: Review and New Technique".
Gundawar, S M; Pande, Neelam A; Jaiswal, Priti; Radke, U M
2014-12-01
For the fabrication of a prosthesis, the Prosthodontist meticulously performs all the steps. The laboratory technician then make every effort/strives to perform the remaining lab procedures. However when the processed dentures are remounted on the articulator, some changes are seen. These changes may be divided into two categories: Pre-insertion and post-insertion changes, which deal with the physical properties of the materials involved (Parker, J Prosthet Dent 31:335-342, 1974). Split cast mounting is the method of mounting casts on the articulator. It is essentially a maxillary cast constructed in two parts with a horizontal division. The procedure allows for the verification of the accuracy of the initial mounting and the ease of removal and replacement of the cast. This provides a precise means of correcting the changes in occlusion occurring as a result of the processing technique (Nogueira et al., J Prosthet Dent 91:386-388, 2004). Instability of the split mounting has always been a problem to the Prosthodontist thereby limiting its use. There are various materials mentioned in the literature. The new technique by using Dowel pins and twill thread is very easy, cheaper and simple way to stabilize the split mounting. It is useful and easy in day to day laboratory procedures. The article presents different methods of split cast mounting and the new procedure using easily available materials in prosthetic laboratory.
Morel, Sylvie; Landreau, Anne; Nguyen, Van Hung; Derbré, Séverine; Grellier, Philippe; Pape, Patrice Le; Pagniez, Fabrice; Litaudon, Marc; Richomme, Pascal
2012-01-01
The Derris genus is known to contain flavonoid derivatives, including prenylated flavanones and isoflavonoids such as rotenoids, which are generally associated with significant biological activity. To develop an efficient preparative isolation procedure for bioactive cajaflavanone. Fast centrifugal partition chromatography (FCPC) was optimised to purify cajaflavanone from Derris ferruginea stems in a single step as compared to fractionation from the cyclohexane extract by successive conventional solid-liquid chromatography procedures. The purification yield, purity, time and solvent consumption per procedure are described. The anti-fungal, anti-bacterial, anti-leishmanial, anti-plasmodial, anti-oxidant activities and the inhibition of advanced glycation end-products (AGEs) by cajaflavanone accumulation are described. FCPC enabled cajaflavanone purification in a single separation step, yielding sufficient quantities to perform in vitro biological screening. Interestingly, cajaflavanone had an inhibitory effect on the formation of AGEs, without displaying any in vitro anti-oxidant activity. A simple and efficient procedure, in comparison with other preparative methods, for bioactive cajaflavone purification has been developed using FCPC. Copyright © 2011 John Wiley & Sons, Ltd.
Rouse, James; Hyde, Christopher
2016-01-06
The threat of thermal fatigue is an increasing concern for thermal power plant operators due to the increasing tendency to adopt "two-shifting" operating procedures. Thermal plants are likely to remain part of the energy portfolio for the foreseeable future and are under societal pressures to generate in a highly flexible and efficient manner. The Green's function method offers a flexible approach to determine reference elastic solutions for transient thermal stress problems. In order to simplify integration, it is often assumed that Green's functions (derived from finite element unit temperature step solutions) are temperature independent (this is not the case due to the temperature dependency of material parameters). The present work offers a simple method to approximate a material's temperature dependency using multiple reference unit solutions and an interpolation procedure. Thermal stress histories are predicted and compared for realistic temperature cycles using distinct techniques. The proposed interpolation method generally performs as well as (if not better) than the optimum single Green's function or the previously-suggested weighting function technique (particularly for large temperature increments). Coefficients of determination are typically above 0 . 96 , and peak stress differences between true and predicted datasets are always less than 10 MPa.
A Geometry Based Infra-structure for Computational Analysis and Design
NASA Technical Reports Server (NTRS)
Haimes, Robert
1997-01-01
The computational steps traditionally taken for most engineering analysis (CFD, structural analysis, and etc.) are: Surface Generation - usually by employing a CAD system; Grid Generation - preparing the volume for the simulation; Flow Solver - producing the results at the specified operational point; and Post-processing Visualization - interactively attempting to understand the results For structural analysis, integrated systems can be obtained from a number of commercial vendors. For CFD, these steps have worked well in the past for simple steady-state simulations at the expense of much user interaction. The data was transmitted between phases via files. Specifically the problems with this procedure are: (1) File based. Information flows from one step to the next via data files with formats specified for that procedure. (2) 'Good' Geometry. A bottleneck in getting results from a solver is the construction of proper geometry to be fed to the grid generator. With 'good' geometry a grid can be constructed in tens of minutes (even with a complex configuration) using unstructured techniques. (3) One-Way communication. All information travels on from one phase to the next. Until this process can be automated, more complex problems such as multi-disciplinary analysis or using the above procedure for design becomes prohibitive.
A convenient Simple Method for Synthesis of Meta-iodobenzylguanidine (MIBG).
Sheikholislam, Zahra; Soleimani, Zohreh; Moghimi, Abolghasem; Shahhosseini, Soraya
2013-01-01
Radioiodinated meta-iodobenzylguanidine (MIBG) is one of the important radiopharmaceuticals in Nuclear Medicine. [(123/131)I] MIBG is used for imaging of Adrenal medulla, studying heart sympathetic nerves, treatment of pheochromacytoma and neuroblastoma. For clinical application, radioiodinated MIBG is prepared through isotopic exchange method, which includes replacement of radioactive iodine in a nucleophilic substitution reaction with cold iodine ((127)I). The unlabelled MIBG hemisulfate is synthesized by the procedure described by Wieland et al. (1980). The availability of a more practical and cost-effective procedure for MIBG preparation encouraged us to study the MIBG synthesis methods. In this study the preparation of MIBG through different methods were evaluated and a new method, which is one step, simple and cost-effective is introduced. The method has ability to be scaled up for production of unlabelled MIBG.
Solving the MHD equations by the space time conservation element and solution element method
NASA Astrophysics Data System (ADS)
Zhang, Moujin; John Yu, S.-T.; Henry Lin, S.-C.; Chang, Sin-Chung; Blankson, Isaiah
2006-05-01
We apply the space-time conservation element and solution element (CESE) method to solve the ideal MHD equations with special emphasis on satisfying the divergence free constraint of magnetic field, i.e., ∇ · B = 0. In the setting of the CESE method, four approaches are employed: (i) the original CESE method without any additional treatment, (ii) a simple corrector procedure to update the spatial derivatives of magnetic field B after each time marching step to enforce ∇ · B = 0 at all mesh nodes, (iii) a constraint-transport method by using a special staggered mesh to calculate magnetic field B, and (iv) the projection method by solving a Poisson solver after each time marching step. To demonstrate the capabilities of these methods, two benchmark MHD flows are calculated: (i) a rotated one-dimensional MHD shock tube problem and (ii) a MHD vortex problem. The results show no differences between different approaches and all results compare favorably with previously reported data.
NASA Technical Reports Server (NTRS)
Huffman, S.
1977-01-01
Detailed instructions on the use of two computer-aided-design programs for designing the energy storage inductor for single winding and two winding dc to dc converters are provided. Step by step procedures are given to illustrate the formatting of user input data. The procedures are illustrated by eight sample design problems which include the user input and the computer program output.
Regis, R R; Alves, C C S; Rocha, S S M; Negreiros, W A; Freitas-Pontes, K M
2016-10-01
The literature has questioned the real need for some clinical and laboratory procedures considered essential for achieving better results for complete denture fabrication. The aim of this study was to review the current literature concerning the relevance of a two-step impression procedure to achieve better clinical results in fabricating conventional complete dentures. Through an electronic search strategy of the PubMed/MEDLINE database, randomised controlled clinical trials which compared complete denture fabrication in adults in which one or two steps of impressions occurred were identified. The selections were made by three independent reviewers. Among the 540 titles initially identified, four studies (seven published papers) reporting on 257 patients evaluating aspects such as oral health-related quality of life, patient satisfaction with dentures in use, masticatory performance and chewing ability, denture quality, direct and indirect costs were considered eligible. The quality of included studies was assessed according to the Cochrane guidelines. The clinical studies considered for this review suggest that a two-step impression procedure may not be mandatory for the success of conventional complete denture fabrication regarding a variety of clinical aspects of denture quality and patients' perceptions of the treatment. © 2016 John Wiley & Sons Ltd.
Solid phase extraction of copper(II) by fixed bed procedure on cation exchange complexing resins.
Pesavento, Maria; Sturini, Michela; D'Agostino, Girolamo; Biesuz, Raffaela
2010-02-19
The efficiency of the metal ion recovery by solid phase extraction (SPE) in complexing resins columns is predicted by a simple model based on two parameters reflecting the sorption equilibria and kinetics of the metal ion on the considered resin. The parameter related to the adsorption equilibria was evaluated by the Gibbs-Donnan model, and that related to the kinetics by assuming that the ion exchange is the adsorption rate determining step. The predicted parameters make it possible to evaluate the breakthrough volume of the considered metal ion, Cu(II), from different kinds of complexing resins, and at different conditions, such as acidity and ionic composition. Copyright 2009. Published by Elsevier B.V.
Reduction of a linear complex model for respiratory system during Airflow Interruption.
Jablonski, Ireneusz; Mroczka, Janusz
2010-01-01
The paper presents methodology of a complex model reduction to its simpler version - an identifiable inverse model. Its main tool is a numerical procedure of sensitivity analysis (structural and parametric) applied to the forward linear equivalent designed for the conditions of interrupter experiment. Final result - the reduced analog for the interrupter technique is especially worth of notice as it fills a major gap in occlusional measurements, which typically use simple, one- or two-element physical representations. Proposed electrical reduced circuit, being structural combination of resistive, inertial and elastic properties, can be perceived as a candidate for reliable reconstruction and quantification (in the time and frequency domain) of dynamical behavior of the respiratory system in response to a quasi-step excitation by valve closure.
Sensing a heart infarction marker with surface plasmon resonance spectroscopy
NASA Astrophysics Data System (ADS)
Kunz, Ulrich; Katerkamp, Andreas; Renneberg, Reinhard; Spener, Friedrich; Cammann, Karl
1995-02-01
In this study a direct immunosensor for heart-type fatty acid binding protein (FABP) based on surface plasmon resonance spectroscopy (SPRS) is presented. FABP can be used as a heart infarction marker in clinical diagnostics. The development of a simple and cheap direct optical sensor device is reported in this paper as well as immobilization procedures and optimization of the measuring conditions. The correct working of the SPRS device is controlled by comparing the signals with theoretical calculated values. Two different immunoassay techniques were optimized for a sensitive FABP-analysis. The competitive immunoassay was superior to the sandwich configuration as it had a lower detection limit (100 ng/ml), needed less antibodies and could be carried out in one step.
Protocol for Removal of Third Molar Root Tips from the Inferior Alveolar Canal-Crossing the line.
Punga, Rohit; Keswani, Kiran
2014-12-01
The safe removal of third molars involved with the inferior alveolar canal (IAC) has been an area of concern since long. Many times we hesitate for the removal of third molars, fearing injury to the inferior alveolar nerve. The authors here describe a simple technique which can be used to remove third molars showing evidence of proximity to IAC on presurgical radiographic evaluation, as well as those root tips which, during removal, accidentally enter the IAC space. A step-by-step protocol is presented along with necessary precautions during the operative procedure.
Shen, Aijin; Wei, Jie; Yan, Jingyu; Jin, Gaowa; Ding, Junjie; Yang, Bingcheng; Guo, Zhimou; Zhang, Feifang; Liang, Xinmiao
2017-03-01
An orthogonal two-dimensional solid-phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed-phase liquid chromatography material (C 18 ) and a weak cation-exchange material (TGA) were integrated in a single solid-phase extraction cartridge. The feasibility of two-dimensional clean-up procedure that experienced two-step adsorption, two-step rinsing, and two-step elution was systematically investigated. Based on the orthogonality of reversed-phase and weak cation-exchange procedures, the two-dimensional solid-phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed-phase solid-phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation-exchange solid-phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two-dimensional clean-up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
SCEW: a Microsoft Excel add-in for easy creation of survival curves.
Khan, Haseeb Ahmad
2006-07-01
Survival curves are frequently used for reporting survival or mortality outcomes of experimental pharmacological/toxicological studies and of clinical trials. Microsoft Excel is a simple and widely used tool for creation of numerous types of graphic presentations however it is difficult to create step-wise survival curves in Excel. Considering the familiarity of clinicians and biomedical scientists with Excel, an algorithm survival curves in Excel worksheet (SCEW) has been developed for easy creation of survival curves directly in Excel worksheets. The algorithm has been integrated in the form of Excel add-in for easy installation and usage. The program is based on modification of frequency data for binary break-up using the spreadsheet formula functions whereas a macro subroutine automates the creation of survival curves. The advantages of this program are simple data input, minimal procedural steps and the creation of survival curves in the familiar confines of Excel.
NASA Astrophysics Data System (ADS)
Batzias, Dimitris F.
2009-08-01
This work deals with a methodological framework under the form of a simple/short algorithmic procedure (including 11 activity steps and 3 decision nodes) designed/developed for the determination of optimal subsidy for materials saving investment through recycle/recovery (RR) at industrial level. Two case examples are presented, covering both aspects, without and with recycling. The expected Relative Cost Decrease (RCD) because of recycling, which forms a critical index for decision making on subsidizing, is estimated. The developed procedure can be extended outside the industrial unit to include collection/transportation/processing of recyclable wasted products. Since, in such a case, transportation cost and processing cost are conflict depended variables (when the quantity collected/processed Q is the independent/explanatory variable), the determination of Qopt is examined under energy crises conditions, when corresponding subsidies might be granted to re-set the original equilibrium and avoid putting the recycling enterprise in jeopardize due to dangerous lowering of the first break-even point.
Taylor, Stephanie N; DiCarlo, Richard P; Martin, David H
2011-11-01
We compared a simple, one-step staining procedure using a mixture of methylene blue and gentian violet to Gram stain for the detection of gonococcal urethritis. The sensitivity and specificity of both Gram stain and methylene blue/gentian violet stain were 97.3% and 99.6%, respectively. There was a 100% correlation between the 2 methods.
JJ Stent Removal under Ultrasound Guidance in Women: It is Simple and Safe.
Amer, Bernard; Gupta, Sandeep; Kanwar, Vijayendra S; Lodh, Bijit; Khumukcham, Somarendra; Akoijam, Kaku Singh
2014-12-01
With the increase in number of patients treated for urological problems with endoscopic procedures, the number of patients with JJ stent is also increasing. The amount of workload thus incurred multiplies, even to the point that, sometimes we waste more time in the operating room removing JJ stents than the actual endourological procedures. Here in our institute, we have devised a very simple and effective way of removing JJ stents in women and also determined the efficacy, safety and cost of JJ stent removal under ultrasound guidance in women in comparison to cystoscopic removal. Two hundred women attending the Department of Urology from July 2012 to July 2013 at RIMS hospital were randomly divided into two arms. One hundred women had their JJ stent removed with cystoscope and another 100 women had their JJ stent removed under ultrasound guidance using simple surgical tools available at the hospital. The primary comparative points were waiting time for operating room appointment date, cost of the procedure, time taken for the procedure, discomfort or pain felt by the patient and urethral injuries. In all the parameters, stent removal under ultrasound guidance was significantly better except for urethral injuries where both the procedures had similar outcomes. We concluded that JJ stent removal under ultrasound guidance in women was simple, effective and safe.
A Simple Technique for Jejunojejunal Revision in Laparoscopic Roux-en-Y Gastric Bypass.
Spivak, Hadar
2015-12-01
The lengths of the bypassed segments in the initial laparoscopic roux-en-Y gastric bypass (LRYGB) are usually a matter of the individual surgeon's routine. The literature is inconclusive about the association between the Roux limbs' length and weight-loss or malabsorption (Stefanidis et al. Obes Surg. 21(1):119-24, 2011); (Rawlins et al. Surg Obes Relat Dis. 7(1):45-9, 2011). However, jejunojejunal anastomosis (JJ) "redo" and Roux limb length revision could be considered for patients with a very short Roux limb and weight loss failure or for short common channel and malabsorption. Complications of JJ may also require revision. In over 1000 LRYGBs since 2001, eight patients required JJ revision for failure to lose enough weight (n = 6), malabsorption (n = 1), and stricture (n = 1). Instead of completely taking down the JJ, a simple technique was evolved to keep the enteric limb continuity. In a following step, the biliopancreatic limbs have been transected from the JJ and reconnected proximal (for malabsorption) or distal (for weight loss failure). In this video, a step-by-step the laparoscopic technique for JJ revision and relocating the biliopancreatic limb is presented. Procedure takes 40-60 min to perform using four trocars and the hospital stay was 1-2 nights. No complications occurred during the procedures or postoperative period. Laparoscopic revision of JJ is feasible and safe and should be part of surgeons' options on the long-term management of patients post LRYGB.
One-step preparation of antimicrobial silver nanoparticles in polymer matrix
NASA Astrophysics Data System (ADS)
Lyutakov, O.; Kalachyova, Y.; Solovyev, A.; Vytykacova, S.; Svanda, J.; Siegel, J.; Ulbrich, P.; Svorcik, V.
2015-03-01
Simple one-step procedure for in situ preparation of silver nanoparticles (AgNPs) in the polymer thin films is described. Nanoparticles (NPs) were prepared by reaction of N-methyl pyrrolidone with silver salt in semi-dry polymer film and characterized by transmission electron microscopy, XPS, and UV-Vis spectroscopy techniques. Direct synthesis of NPs in polymer has several advantages; even though it avoids time-consuming NPs mixing with polymer matrix, uniform silver distribution in polymethylmethacrylate (PMMA) films is achieved without necessity of additional stabilization. The influence of the silver concentration, reaction temperature and time on reaction conversion rate, and the size and size-distribution of the AgNPs was investigated. Polymer films doped with AgNPs were tested for their antibacterial activity on Gram-negative bacteria. Antimicrobial properties of AgNPs/PMMA films were found to be depended on NPs concentration, their size and distribution. Proposed one-step synthesis of functional polymer containing AgNPs is environmentally friendly, experimentally simple and extremely quick. It opens up new possibilities in development of antimicrobial coatings with medical and sanitation applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, Haiming; Lin, Yaojun; Seidman, David N.
The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less
Simplified method to solve sound transmission through structures lined with elastic porous material.
Lee, J H; Kim, J
2001-11-01
An approximate analysis method is developed to calculate sound transmission through structures lined with porous material. Because the porous material has both the solid phase and fluid phase, three wave components exist in the material, which makes the related analysis very complicated. The main idea in developing the approximate method is very simple: modeling the porous material using only the strongest of the three waves, which in effect idealizes the material as an equivalent fluid. The analysis procedure has to be conducted in two steps. In the first step, sound transmission through a flat double panel with a porous liner of infinite extents, which has the same cross sectional construction as the actual structure, is solved based on the full theory and the strongest wave component is identified. In the second step sound transmission through the actual structure is solved modeling the porous material as an equivalent fluid while using the actual geometry of the structure. The development and validation of the method are discussed in detail. As an application example, the transmission loss through double walled cylindrical shells with a porous core is calculated utilizing the simplified method.
Wen, Haiming; Lin, Yaojun; Seidman, David N.; ...
2015-09-09
The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less
Correlation and simple linear regression.
Eberly, Lynn E
2007-01-01
This chapter highlights important steps in using correlation and simple linear regression to address scientific questions about the association of two continuous variables with each other. These steps include estimation and inference, assessing model fit, the connection between regression and ANOVA, and study design. Examples in microbiology are used throughout. This chapter provides a framework that is helpful in understanding more complex statistical techniques, such as multiple linear regression, linear mixed effects models, logistic regression, and proportional hazards regression.
Poly(ethylene oxide) functionalization
Pratt, Russell Clayton
2014-04-08
A simple procedure is provided by which the hydroxyl termini of poly(ethylene oxide) can be appended with functional groups to a useful extent by reaction and precipitation. The polymer is dissolved in warmed toluene, treated with an excess of organic base and somewhat less of an excess of a reactive acylating reagent, reacted for several hours, then precipitated in isopropanol so that the product can be isolated as a solid, and salt byproducts are washed away. This procedure enables functionalization of the polymer while not requiring laborious purification steps such as solvent-solvent extraction or dialysis to remove undesirable side products.
Procedural key steps in laparoscopic colorectal surgery, consensus through Delphi methodology.
Dijkstra, Frederieke A; Bosker, Robbert J I; Veeger, Nicolaas J G M; van Det, Marc J; Pierie, Jean Pierre E N
2015-09-01
While several procedural training curricula in laparoscopic colorectal surgery have been validated and published, none have focused on dividing surgical procedures into well-identified segments, which can be trained and assessed separately. This enables the surgeon and resident to focus on a specific segment, or combination of segments, of a procedure. Furthermore, it will provide a consistent and uniform method of training for residents rotating through different teaching hospitals. The goal of this study was to determine consensus on the key steps of laparoscopic right hemicolectomy and laparoscopic sigmoid colectomy among experts in our University Medical Center and affiliated hospitals. This will form the basis for the INVEST video-assisted side-by-side training curriculum. The Delphi method was used for determining consensus on key steps of both procedures. A list of 31 steps for laparoscopic right hemicolectomy and 37 steps for laparoscopic sigmoid colectomy was compiled from textbooks and national and international guidelines. In an online questionnaire, 22 experts in 12 hospitals within our teaching region were invited to rate all steps on a Likert scale on importance for the procedure. Consensus was reached in two rounds. Sixteen experts agreed to participate. Of these 16 experts, 14 (88%) completed the questionnaire for both procedures. Of the 14 who completed the first round, 13 (93%) completed the second round. Cronbach's alpha was 0.79 for the right hemicolectomy and 0.91 for the sigmoid colectomy, showing high internal consistency between the experts. For the right hemicolectomy, 25 key steps were established; for the sigmoid colectomy, 24 key steps were established. Expert consensus on the key steps for laparoscopic right hemicolectomy and laparoscopic sigmoid colectomy was reached. These key steps will form the basis for a video-assisted teaching curriculum.
48 CFR 6.102 - Use of competitive procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ACQUISITION PLANNING COMPETITION REQUIREMENTS Full and Open Competition 6.102 Use of competitive procedures. The competitive procedures available for use in fulfilling the requirement for full and open... procedures (e.g., two-step sealed bidding). (d) Other competitive procedures. (1) Selection of sources for...
Mufarrij, Patrick W; Rajamahanty, Srinivas; Krane, L Spencer; Hemal, Ashok K
2012-09-01
An integral component of many urologic reconstructive surgical procedures is the positioning of a Double-J stent to span the anastomosis. Some surgeons prefer to place a retrograde stent during cystoscopy, either during or after the reconstruction. In this communication, we describe our straightforward and effective approach of performing this critical step intracorporeally using robotic assistance in a variety of upper tract urologic reconstructive procedures. We examined our Institutional Review Board-approved database of robotic surgeries to identify reconstructive operations that included the intracorporeal placement of a Double-J stent since 2008. Our step-by-step method for stent placement during various robotic urologic reconstructions is detailed, including procedures involving the proximal, mid, and distal ureter. With the aid of a bedside assistant-surgeon, we delineate how the console surgeon is able to perform this step of the procedure completely intracorporeally, without the need for repositioning or cystoscopy. Since the inception of our robotic surgical program in 2008, we have used these robotic stent placement techniques in 150 patients. The average time of robotic intracorporeal stent placement across the anastomosis was 3.5 minutes. Three patients did experience proximal stent migration, as documented on postoperative radiographs, but all were treated with conservative measures, because their anastomosis was not affected and severe symptoms did not develop. No patient needed stent replacement, and each stent was subsequently removed ureteroscopically without sequelae. Our robotic intracorporeal Double-J stent placement approach is simple and effective, avoids the need for cystoscopy and fluoroscopy, and can be used in any type of upper urinary tract urologic reconstruction.
Merlos Rodrigo, Miguel Angel; Krejcova, Ludmila; Kudr, Jiri; Cernei, Natalia; Kopel, Pavel; Richtera, Lukas; Moulick, Amitava; Hynek, David; Adam, Vojtech; Stiborova, Marie; Eckschlager, Tomas; Heger, Zbynek; Zitka, Ondrej
2016-12-15
Metallothioneins (MTs) are involved in heavy metal detoxification in a wide range of living organisms. Currently, it is well known that MTs play substantial role in many pathophysiological processes, including carcinogenesis, and they can serve as diagnostic biomarkers. In order to increase the applicability of MT in cancer diagnostics, an easy-to-use and rapid method for its detection is required. Hence, the aim of this study was to develop a fully automated and high-throughput assay for the estimation of MT levels. Here, we report the optimal conditions for the isolation of MTs from rabbit liver and their characterization using MALDI-TOF MS. In addition, we described a two-step assay, which started with an isolation of the protein using functionalized paramagnetic particles and finished with their electrochemical analysis. The designed easy-to-use, cost-effective, error-free and fully automated procedure for the isolation of MT coupled with a simple analytical detection method can provide a prototype for the construction of a diagnostic instrument, which would be appropriate for the monitoring of carcinogenesis or MT-related chemoresistance of tumors. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Wolf, Stephen W. D.; Goodyer, Michael J.
1988-01-01
Following the realization that a simple iterative strategy for bringing the flexible walls of two-dimensional test sections to streamline contours was too slow for practical use, Judd proposed, developed, and placed into service what was the first Predictive Strategy. The Predictive Strategy reduced by 75 percent or more the number of iterations of wall shapes, and therefore the tunnel run-time overhead attributable to the streamlining process, required to reach satisfactory streamlines. The procedures of the Strategy are embodied in the FORTRAN subroutine WAS (standing for Wall Adjustment Strategy) which is written in general form. The essentials of the test section hardware, followed by the underlying aerodynamic theory which forms the basis of the Strategy, are briefly described. The subroutine is then presented as the Appendix, broken down into segments with descriptions of the numerical operations underway in each, with definitions of variables.
Solid-phase extraction NMR studies of chromatographic fractions of saponins from Quillaja saponaria.
Nyberg, Nils T; Baumann, Herbert; Kenne, Lennart
2003-01-15
The saponin mixture QH-B from the tree Quillaja saponaria var. Molina was fractionated by RP-HPLC in several steps. The fractions were analyzed by solid-phase extraction NMR (SPE-NMR), a technique combining the workup by solid-phase extraction with on-line coupling to an NMR flow probe. Together with MALDI-TOF mass spectrometry and comparison with chemical shifts of similar saponins, the structures of both major and minor components in QH-B could be obtained. The procedure described is a simple method to determine the structure of components in a complex mixture. The two major fractions of the mixture were found to contain at least 28 saponins, differing in the carbohydrate substructures. Eight of these have not previously been determined. The 28 saponins formed 14 equilibrium pairs by the migration of an O-acyl group between two adjacent positions on a fucosyl residue.
Methods and systems for detection of radionuclides
Coates, Jr., John T.; DeVol, Timothy A.
2010-05-25
Disclosed are materials and systems useful in determining the existence of radionuclides in an aqueous sample. The materials provide the dual function of both extraction and scintillation to the systems. The systems can be both portable and simple to use, and as such can beneficially be utilized to determine presence and optionally concentration of radionuclide contamination in an aqueous sample at any desired location and according to a relatively simple process without the necessity of complicated sample handling techniques. The disclosed systems include a one-step process, providing simultaneous extraction and detection capability, and a two-step process, providing a first extraction step that can be carried out in a remote field location, followed by a second detection step that can be carried out in a different location.
An infinite-order two-component relativistic Hamiltonian by a simple one-step transformation.
Ilias, Miroslav; Saue, Trond
2007-02-14
The authors report the implementation of a simple one-step method for obtaining an infinite-order two-component (IOTC) relativistic Hamiltonian using matrix algebra. They apply the IOTC Hamiltonian to calculations of excitation and ionization energies as well as electric and magnetic properties of the radon atom. The results are compared to corresponding calculations using identical basis sets and based on the four-component Dirac-Coulomb Hamiltonian as well as Douglas-Kroll-Hess and zeroth-order regular approximation Hamiltonians, all implemented in the DIRAC program package, thus allowing a comprehensive comparison of relativistic Hamiltonians within the finite basis approximation.
Functional-to-form mapping for assembly design automation
NASA Astrophysics Data System (ADS)
Xu, Z. G.; Liu, W. M.; Shen, W. D.; Yang, D. Y.; Liu, T. T.
2017-11-01
Assembly-level function-to-form mapping is the most effective procedure towards design automation. The research work mainly includes: the assembly-level function definitions, product network model and the two-step mapping mechanisms. The function-to-form mapping is divided into two steps, i.e. mapping of function-to-behavior, called the first-step mapping, and the second-step mapping, i.e. mapping of behavior-to-structure. After the first step mapping, the three dimensional transmission chain (or 3D sketch) is studied, and the feasible design computing tools are developed. The mapping procedure is relatively easy to be implemented interactively, but, it is quite difficult to finish it automatically. So manual, semi-automatic, automatic and interactive modification of the mapping model are studied. A mechanical hand F-F mapping process is illustrated to verify the design methodologies.
Composting. Sludge Treatment and Disposal Course #166. Instructor's Guide [and] Student Workbook.
ERIC Educational Resources Information Center
Arasmith, E. E.
Composting is a lesson developed for a sludge treatment and disposal course. The lesson discusses the basic theory of composting and the basic operation, in a step-by-step sequence, of the two typical composting procedures: windrow and forced air static pile. The lesson then covers basic monitoring and operational procedures. The instructor's…
Di Muccio, A; Barbini, D A; Generali, T; Pelosi, P; Ausili, A; Vergori, F; Camoni, I
1997-03-21
Disposable, ready-to-use cartridges filled with macroporous diatomaceous material are used to carry out a partition clean-up that, in a single step, is capable of transferring pesticide residues from aqueous acetone extracts into light petroleum-dichloromethane (75:25, v/v). This procedure takes the place of some functions (such as separatory-funnel partition, drying over anhydrous sodium sulphate and partial adsorption clean-up) usually performed by separate steps in classical schemes. Fourteen pyrethroid pesticides, including tefluthrin, tetramethrin, cyphenothrin, cyfluthrin, flucythrinate, tau-fluvalinate, deltamethrin, bioallethrin, fenpropathrin, lambda-cyhalothrin, permethrin, alpha-cypermethrin, esfenvalerate and tralomethrin were determined using the described procedure with satisfactory recoveries for most of them, at spiking levels ranging from 0.08 to 0.82 mg/kg for the different compounds. Crops subjected to the described procedure included strawberry, apple, and orange gave extracts containing a mass of co-extractives that was between 5 and 30 mg. Compared with classical schemes, the described procedure is simple, less labour intensive, allows parallel handling of several extracts and does not require the preparation and maintenance of equipment. Troublesome emulsions such as those frequently observed in separation funnel partitioning do not occur.
A Fast Proceduere for Optimizing Thermal Protection Systems of Re-Entry Vehicles
NASA Astrophysics Data System (ADS)
Ferraiuolo, M.; Riccio, A.; Tescione, D.; Gigliotti, M.
The aim of the present work is to introduce a fast procedure to optimize thermal protection systems for re-entry vehicles subjected to high thermal loads. A simplified one-dimensional optimization process, performed in order to find the optimum design variables (lengths, sections etc.), is the first step of the proposed design procedure. Simultaneously, the most suitable materials able to sustain high temperatures and meeting the weight requirements are selected and positioned within the design layout. In this stage of the design procedure, simplified (generalized plane strain) FEM models are used when boundary and geometrical conditions allow the reduction of the degrees of freedom. Those simplified local FEM models can be useful because they are time-saving and very simple to build; they are essentially one dimensional and can be used for optimization processes in order to determine the optimum configuration with regard to weight, temperature and stresses. A triple-layer and a double-layer body, subjected to the same aero-thermal loads, have been optimized to minimize the overall weight. Full two and three-dimensional analyses are performed in order to validate those simplified models. Thermal-structural analyses and optimizations are executed by adopting the Ansys FEM code.
How quantizable matter gravitates: A practitioner's guide
NASA Astrophysics Data System (ADS)
Schuller, Frederic P.; Witte, Christof
2014-05-01
We present the practical step-by-step procedure for constructing canonical gravitational dynamics and kinematics directly from any previously specified quantizable classical matter dynamics, and then illustrate the application of this recipe by way of two completely worked case studies. Following the same procedure, any phenomenological proposal for fundamental matter dynamics must be supplemented with a suitable gravity theory providing the coefficients and kinematical interpretation of the matter theory, before any of the two theories can be meaningfully compared to experimental data.
An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.
ERIC Educational Resources Information Center
Moehs, Peter J.; Levine, Samuel
1982-01-01
A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…
Allouche, Joachim; Dupin, Jean-Charles; Gonbeau, Danielle
2011-07-14
Silica core-shell nanoparticles with a MSU shell have been synthesized using several non-ionic poly(ethylene oxide) based surfactants via a two step sol-gel method. The materials exhibit a typical worm-hole pore structure and tunable pore diameters between 2.4 nm and 5.8 nm.
Simplified methods for the construction of RNA and DNA virus infectious clones.
Nagata, Tatsuya; Inoue-Nagata, Alice Kazuko
2015-01-01
Infectious virus clones are one of the most powerful tools in plant pathology, molecular biology, and biotechnology. The construction of infectious clones of RNA and DNA viruses, however, usually requires laborious cloning and subcloning steps. In addition, instability of the RNA virus genome is frequently reported after its introduction into the vector and transference to Escherichia coli. These difficulties hamper the cloning procedures, making it tedious and cumbersome. This chapter describes two protocols for a simple construction of infectious viruses, an RNA virus, the tobamovirus Pepper mild mottle virus, and a DNA virus, a bipartite begomovirus. For this purpose, the strategy of overlap-extension PCR was used for the construction of infectious tobamovirus clone and of rolling circle amplification (RCA) for the construction of a dimeric form of the begomovirus clone.
NASA Astrophysics Data System (ADS)
Prakash, B.; Asha, S.; Nimrodh Ananth, A.; Vanithakumari, G.; Okram, G. S.; Jose, Sujin P.; Jothi Rajan, M. A.
2018-02-01
Chitosan/tripolyphosphate polyelectrolyte (TPP) microspheres, decorated and surface functionalized with silver nanoparticles (NPs) of average diameter of 15 nm, were synthesized following a simple two-step procedure. These Ag NP-functionalized polyelectrolyte microspheres (Ag-CSPMs) are found to be biocompatible and enhancing the reactive oxygen species in curcumin with excellent anti-bacterial activity for selected Gram-positive and negative bacterial strains, making them much attractive relative to bare surface counterparts; the well-stabilized silver NPs do not form any agglomerations on the surface of the chitosan microspheres. They also show excellent cytotoxic behavior towards MCF7 cell lines, showing a half-maximal inhibitory concentration (IC50) of 32 μg ml-1. Therefore, Ag-CSPMs exhibit multi-functional ability having potential towards theranostics applications.
A novel calibration method for non-orthogonal shaft laser theodolite measurement system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Bin, E-mail: wubin@tju.edu.cn, E-mail: xueting@tju.edu.cn; Yang, Fengting; Ding, Wen
2016-03-15
Non-orthogonal shaft laser theodolite (N-theodolite) is a new kind of large-scale metrological instrument made up by two rotary tables and one collimated laser. There are three axes for an N-theodolite. According to naming conventions in traditional theodolite, rotary axes of two rotary tables are called as horizontal axis and vertical axis, respectively, and the collimated laser beam is named as sight axis. And the difference between N-theodolite and traditional theodolite is obvious, since the former one with no orthogonal and intersecting accuracy requirements. So the calibration method for traditional theodolite is no longer suitable for N-theodolite, while the calibration methodmore » applied currently is really complicated. Thus this paper introduces a novel calibration method for non-orthogonal shaft laser theodolite measurement system to simplify the procedure and to improve the calibration accuracy. A simple two-step process, calibration for intrinsic parameters and for extrinsic parameters, is proposed by the novel method. And experiments have shown its efficiency and accuracy.« less
Treatment of congenital anophthalmos with self-inflating polymer expanders: a new method.
Wiese, K G; Vogel, M; Guthoff, R; Gundlach, K K
1999-04-01
Congenital anophthalmos is a rare malformation in which the optic vesicle fails to develop. This leads to a small bony orbit, a constricted mucosal socket, short eyelids, reduced palpebral fissure and malar hypoplasia. The treatment includes both aesthetic and functional aspects. Therefore, a two-step procedure is described using a new self-inflating hydrogel expander. A lens-shaped expander with a diameter of 8 mm expands the lids and the mucosal socket to allow insertion of an eye prosthesis. As a second step, orbital expansion is performed with a spherical device. The expanders absorb lacrimal fluid from the mucosal socket or tissue fluid and start swelling when implanted in the orbital tissue. The insertion of an expander into the orbit as well as into the conjunctival pocket including its fixation by a single suture took only a few minutes and was an easy procedure. The expansion of the small conjunctival sockets was successfully completed in all cases within a period of 2-4 weeks. The weight (= volume in ml) of devices increased from 0.15-1.5 g (lens-shaped expander; weight in grams = volume in ml) respectively, 0.3-3.5 g (spherical device). The expanders inserted in orbital tissue increased from 0.4-4.4 g. This is equivalent to a 10 to 11 fold increase in their water-free volumes. Orbital expansion with spherical devices in combination with the inserted eye prosthesis enlarges the lid and palpebral fissures also. In contrast to conventional silicon balloon expanders, the procedure using self-inflating hydrogel expanders is simple and highly efficient.
Suslu, Husnu
2012-01-01
Laboratory training models are essential for developing and refining treatment skills before the clinical application of surgical and invasive procedures. A simple simulation model is needed for young trainees to learn how to handle instruments, and to perform safe lumbar transforaminal epidural injections. Our aim is to present a model of a fresh cadaveric sheep lumbar spine that simulates the lumbar transforaminal epidural injection. The material consists of a 2-year-old fresh cadaveric sheep spine. A 4-step approach was designed for lumbar transforaminal epidural injection under C-arm scopy. For the lumbar transforaminal epidural injection, the fluoroscope was adjusted to get a proper oblique view while the material was stabilized in a prone position. The procedure then begin, using the C-arm guidance scopy. The model simulates well the steps of standard lumbar transforaminal epidural injections in the human spine. The cadaveric sheep spine represents a good method for training and it simulates fluoroscopic lumbar transforaminal epidural steroid injection procedures performed in the human spine.
Núñez, L; Turiel, E; Tadeo, J L
2007-04-06
A simple and rapid analytical method for the determination of nonylphenol (NP) and nonylphenol ethoxylates (NPEOx) in solid environmental samples has been developed. This method combines an ultrasonic-assisted extraction procedure in small columns and an enrichment step onto C(18) solid-phase extraction cartridges prior to separation using HPLC with fluorescence detection. Method optimization was carried out using soil samples fortified at different concentration levels (from 0.1 to 100 microg/g). Under optimum conditions, 2g of soil was placed in small glass columns and extraction was performed assisted by sonication (SAESC) at 45 degrees C in two consecutive steps of 15 min using a mixture of H(2)O/MeOH (30/70). The obtained extracts were collected, loaded onto 500 mg C(18) cartridges, and analytes were eluted with 3 x 1 ml of methanol and 1 ml of acetonitrile. Finally, sample extracts were evaporated under a nitrogen stream, redissolved in 500 microl H(2)O/AcN (50/50), and passed though a 0.45 microm nylon filter before final determination by HPLC-FL. The developed procedure allowed to achieve quantitative recoveries for NP and NPEOx, and was properly validated. Finally, the method was applied to the determination of these compounds in soils and other environmental solid samples such as sediments, compost and sludge.
Practices & Procedures of Mason Tending I & II. Instructor Manual. Trainee Manual.
ERIC Educational Resources Information Center
Laborers-AGC Education and Training Fund, Pomfret Center, CT.
This packet consists of the instructor and trainee manuals for two courses: practices and procedures of mason tending I and II. The instructor manual for mason tending I contains a schedule for a 40-hour, 5-day course and instructor outline. The outline provides a step-by-step description of the instructor's activities and includes answer sheets…
Liu, Yan; Yang, Shanli; Niu, Weifen
2013-08-01
Simple, rapid, green and one-step electrodeposition strategy was first proposed to synthesis of graphene/carbon nanotubes/chitosan (GR/CNTs/CS) hybrid. The one-step electrodeposition approach for the construction of GR-based hybrid is green environmentally, which would not involve the chemical reduction of graphene oxide (GO) and therefore result in no further contamination. The whole procedure is simple and needs only several minutes. Combining the advantages of GR (large surface area, high conductivity and good adsorption ability), CNTs (high surface area, high enrichment capability and good adsorption ability) and CS (good adsorption and excellent film-forming ability), the obtained GR/CNTs/CS composite could be highly efficient to capture organophosphate pesticides (OPs) and used as solid phase extraction (SPE). The GR/CNTs/CS sensor is used for enzymeless detection of OPs, using methyl parathion (MP) as a model analyte. Significant redox response of MP on GR/CNTs/CS sensor is proved. The linear range is wide from 2.0ngmL(-1) to 500ngmL(-1), with a detection limit of 0.5ngmL(-1). Detection limit of the proposed sensor is much lower than those enzyme-based sensors and many other enzymeless sensors. Moreover, the proposed sensor exhibits high reproducibility, long-time storage stability and satisfactory anti-interference ability. This work provides a green and one-step route for the preparation of GR-based hybrid, and also offers a new promising protocol for OPs analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Radiofrequency Ablation of Lung Tumors
... the procedure. top of page What does the equipment look like? In this procedure, computed tomography (CT) ... electrical generator and grounding pads are used. Radiofrequency equipment There are two types of needle electrodes: simple ...
Radiofrequency Ablation of Liver Tumors
... the procedure. top of page What does the equipment look like? The equipment used in this procedure ... and grounding pads may also be used. Radiofrequency equipment There are two types of needle electrodes: simple ...
NASA Technical Reports Server (NTRS)
Smedes, H. W.; Linnerud, H. J.; Woolaver, L. B.; Su, M. Y.; Jayroe, R. R.
1972-01-01
Two clustering techniques were used for terrain mapping by computer of test sites in Yellowstone National Park. One test was made with multispectral scanner data using a composite technique which consists of (1) a strictly sequential statistical clustering which is a sequential variance analysis, and (2) a generalized K-means clustering. In this composite technique, the output of (1) is a first approximation of the cluster centers. This is the input to (2) which consists of steps to improve the determination of cluster centers by iterative procedures. Another test was made using the three emulsion layers of color-infrared aerial film as a three-band spectrometer. Relative film densities were analyzed using a simple clustering technique in three-color space. Important advantages of the clustering technique over conventional supervised computer programs are (1) human intervention, preparation time, and manipulation of data are reduced, (2) the computer map, gives unbiased indication of where best to select the reference ground control data, (3) use of easy to obtain inexpensive film, and (4) the geometric distortions can be easily rectified by simple standard photogrammetric techniques.
ERIC Educational Resources Information Center
Smyth, Sinead; Barnes-Holmes, Dermot; Forsyth, John P.
2006-01-01
Two experiments investigated the derived transfer of functions through equivalence relations established using a stimulus pairing observation procedure. In Experiment 1, participants were trained on a simple discrimination (A1+/A2-) and then a stimulus pairing observation procedure was used to establish 4 stimulus pairings (A1-B1, A2-B2, B1-C1,…
The selection of adhesive systems for resin-based luting agents.
Carville, Rebecca; Quinn, Frank
2008-01-01
The use of resin-based luting agents is ever expanding with the development of adhesive dentistry. A multitude of different adhesive systems are used with resin-based luting agents, and new products are introduced to the market frequently. Traditional adhesives generally required a multiple step bonding procedure prior to cementing with active resin-based luting materials; however, combined agents offer a simple application procedure. Self-etching 'all-in-one' systems claim that there is no need for the use of a separate adhesive process. The following review addresses the advantages and disadvantages of the available adhesive systems used with resin-based luting agents.
Wang, Shau-Chun; Huang, Chih-Min; Chiang, Shu-Min
2007-08-17
This paper reports a simple chemometric technique to alter the noise spectrum of liquid chromatography-tandem mass spectrometry (LC-MS-MS) chromatogram between two consecutive matched filter procedures to improve the peak signal-to-noise (S/N) ratio enhancement. This technique is to multiply one match-filtered LC-MS-MS chromatogram with another artificial chromatogram added with thermal noises prior to the second matched filter. Because matched filter cannot eliminate low-frequency components inherent in the flicker noises of spike-like sharp peaks randomly riding on LC-MS-MS chromatograms, efficient peak S/N ratio improvement cannot be accomplished using one-step or consecutive matched filter procedures to process LC-MS-MS chromatograms. In contrast, when the match-filtered LC-MS-MS chromatogram is conditioned with the multiplication alteration prior to the second matched filter, much better efficient ratio improvement is achieved. The noise frequency spectrum of match-filtered chromatogram, which originally contains only low-frequency components, is altered to span a boarder range with multiplication operation. When the frequency range of this modified noise spectrum shifts toward higher frequency regime, the second matched filter, working as a low-pass filter, is able to provide better filtering efficiency to obtain higher peak S/N ratios. Real LC-MS-MS chromatograms containing random spike-like peaks, of which peak S/N ratio improvement is less than four times with two consecutive matched filters typically, are remedied to accomplish much better ratio enhancement approximately 16-folds when the noise frequency spectrum is modified between two matched filters.
Preparative two-step purification of recombinant H1.0 linker histone and its domains.
Ivic, Nives; Bilokapic, Silvija; Halic, Mario
2017-01-01
H1 linker histones are small basic proteins that have a key role in the formation and maintenance of higher-order chromatin structures. Additionally, many examples have shown that linker histones play an important role in gene regulation, modulated by their various subtypes and posttranslational modifications. Obtaining high amounts of very pure linker histones, especially for efficient antibody production, remains a demanding and challenging procedure. Here we present an easy and fast method to purify human linker histone H1.0 overexpressed in Escherichia coli, as well as its domains: N-terminal/globular domain and C-terminal intrinsically disordered domain. This purification protocol relies on a simple affinity chromatography step followed by cation exchange due to the highly basic properties of histone proteins. Therefore, this protocol can also be applied to other linker histones. Highly pure proteins in amounts sufficient for most biochemical experiments can be obtained. The functional quality of purified H1.0 histone and its domains has been confirmed by pull-down, gel-mobility shift assays and the nuclear import assay.
More Powerful Tests of Simple Interaction Contrasts in the Two-Way Factorial Design
ERIC Educational Resources Information Center
Hancock, Gregory R.; McNeish, Daniel M.
2017-01-01
For the two-way factorial design in analysis of variance, the current article explicates and compares three methods for controlling the Type I error rate for all possible simple interaction contrasts following a statistically significant interaction, including a proposed modification to the Bonferroni procedure that increases the power of…
1990-08-01
the guidance in this report. 1-4. Scope This guidance covers selection of projects suitable for a One-Step or Two-Step approach, development of design...conducted, focus on resolving proposal deficiencies; prices are not "negotiated" in the common use of the term. A Request for Proposal (RFP) states project ...carefully examines experience and past performance in the design of similar projects and building types. Quality of
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu, Yu; Lei, Jixue; Yin, Bing
2014-03-17
A simple two-step hydrothermal process was proposed for enhancing the performance of the nanogenerator on flexible and wearable terylene-fabric substrate. With this method, a significant enhancement in output voltage of the nanogenerator from ∼10 mV to 7 V was achieved, comparing with the one by conventional one-step process. In addition, another advantage with the devices synthesized by two-step hydrothermal process was that their output voltages are only sensitive to strain rather than strain rate. The devices with a high output voltage have the ability to power common electric devices and will have important applications in flexible electronics and wearable devices.
Photo-Modeling and Cloud Computing. Applications in the Survey of Late Gothic Architectural Elements
NASA Astrophysics Data System (ADS)
Casu, P.; Pisu, C.
2013-02-01
This work proposes the application of the latest methods of photo-modeling to the study of Gothic architecture in Sardinia. The aim is to consider the versatility and ease of use of such documentation tools in order to study architecture and its ornamental details. The paper illustrates a procedure of integrated survey and restitution, with the purpose to obtain an accurate 3D model of some gothic portals. We combined the contact survey and the photographic survey oriented to the photo-modelling. The software used is 123D Catch by Autodesk an Image Based Modelling (IBM) system available free. It is a web-based application that requires a few simple steps to produce a mesh from a set of not oriented photos. We tested the application on four portals, working at different scale of detail: at first the whole portal and then the different architectural elements that composed it. We were able to model all the elements and to quickly extrapolate simple sections, in order to make a comparison between the moldings, highlighting similarities and differences. Working in different sites at different scale of detail, have allowed us to test the procedure under different conditions of exposure, sunshine, accessibility, degradation of surface, type of material, and with different equipment and operators, showing if the final result could be affected by these factors. We tested a procedure, articulated in a few repeatable steps, that can be applied, with the right corrections and adaptations, to similar cases and/or larger or smaller elements.
ERIC Educational Resources Information Center
Naturescope, 1986
1986-01-01
Presents step-by-step procedures for two arts and crafts lessons that focus on mammals. Directions are offered for making mammal-shaped dough magnets and also for creating mammal note cards. Examples of each are illustrated. (ML)
Additivity of nonlinear biomass equations
Bernard R. Parresol
2001-01-01
Two procedures that guarantee the property of additivity among the components of tree biomass and total tree biomass utilizing nonlinear functions are developed. Procedure 1 is a simple combination approach, and procedure 2 is based on nonlinear joint-generalized regression (nonlinear seemingly unrelated regressions) with parameter restrictions. Statistical theory is...
Balancing Chemical Equations: The Role of Developmental Level and Mental Capacity.
ERIC Educational Resources Information Center
Niaz, Mansoor; Lawson, Anton E.
1985-01-01
Tested two hypotheses: (1) formal reasoning is required to balance simple one-step equations; and (2) formal reasoning plus sufficient mental capacity are required to balance many-step equations. Independent variables included intellectual development, mental capacity, and degree of field dependence/independence. With 25 subjects, significance was…
ERIC Educational Resources Information Center
Wilder, David A.; Atwell, Julie; Wine, Byron
2006-01-01
The effects of three levels of treatment integrity (100%, 50%, and 0%) on child compliance were evaluated in the context of the implementation of a three-step prompting procedure. Two typically developing preschool children participated in the study. After baseline data on compliance to one of three common demands were collected, a therapist…
A Simple Sonication Improves Protein Signal in Matrix-Assisted Laser Desorption Ionization Imaging
NASA Astrophysics Data System (ADS)
Lin, Li-En; Su, Pin-Rui; Wu, Hsin-Yi; Hsu, Cheng-Chih
2018-02-01
Proper matrix application is crucial in obtaining high quality matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI). Solvent-free sublimation was essentially introduced as an approach of homogeneous coating that gives small crystal size of the organic matrix. However, sublimation has lower extraction efficiency of analytes. Here, we present that a simple sonication step after the hydration in standard sublimation protocol significantly enhances the sensitivity of MALDI MSI. This modified procedure uses a common laboratory ultrasonicator to immobilize the analytes from tissue sections without noticeable delocalization. Improved imaging quality with additional peaks above 10 kDa in the spectra was thus obtained upon sonication treatment. [Figure not available: see fulltext.
A Two-Step Approach to Analyze Satisfaction Data
ERIC Educational Resources Information Center
Ferrari, Pier Alda; Pagani, Laura; Fiorio, Carlo V.
2011-01-01
In this paper a two-step procedure based on Nonlinear Principal Component Analysis (NLPCA) and Multilevel models (MLM) for the analysis of satisfaction data is proposed. The basic hypothesis is that observed ordinal variables describe different aspects of a latent continuous variable, which depends on covariates connected with individual and…
Read Two Impress: An Intervention for Disfluent Readers
ERIC Educational Resources Information Center
Young, Chase; Rasinski, Timothy; Mohr, Kathleen A. J.
2016-01-01
The authors describe a research-based method to increase students' reading fluency. The method is called Read Two Impress, which is derived from the Neurological Impress Method and the method of repeated readings. The authors provide step-by-step procedures to effectively implement the reading fluency intervention. Previous research indicates that…
Two-Step Semi-Microscale Preparation of a Cinnamate Ester Sunscreen Analog
ERIC Educational Resources Information Center
Stabile, Ryan G.; Dicks, Andrew P.
2004-01-01
A student procedure focusing on multistep sunscreen synthesis and spectroscopic analysis is reported. A two-step synthetic pathway towards sunscreens, an analog of a commercially available UV light blocker is designed, given the current high profile nature of skin cancer and media attention towards sunscreens.
A novel two-step method for screening shade tolerant mutant plants via dwarfism
USDA-ARS?s Scientific Manuscript database
When subjected to shade, plants undergo rapid shoot elongation, which often makes them more prone to disease and mechanical damage. It has been reported that, in turfgrass, induced dwarfism can enhance shade tolerance. Here, we describe a two-step procedure for isolating shade tolerant mutants of ...
Individualizing drug dosage with longitudinal data.
Zhu, Xiaolu; Qu, Annie
2016-10-30
We propose a two-step procedure to personalize drug dosage over time under the framework of a log-linear mixed-effect model. We model patients' heterogeneity using subject-specific random effects, which are treated as the realizations of an unspecified stochastic process. We extend the conditional quadratic inference function to estimate both fixed-effect coefficients and individual random effects on a longitudinal training data sample in the first step and propose an adaptive procedure to estimate new patients' random effects and provide dosage recommendations for new patients in the second step. An advantage of our approach is that we do not impose any distribution assumption on estimating random effects. Moreover, the new approach can accommodate more general time-varying covariates corresponding to random effects. We show in theory and numerical studies that the proposed method is more efficient compared with existing approaches, especially when covariates are time varying. In addition, a real data example of a clozapine study confirms that our two-step procedure leads to more accurate drug dosage recommendations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Stockwell, Alan E.; Cooper, Paul A.
1991-01-01
The Integrated Multidisciplinary Analysis Tool (IMAT) consists of a menu driven executive system coupled with a relational database which links commercial structures, structural dynamics and control codes. The IMAT graphics system, a key element of the software, provides a common interface for storing, retrieving, and displaying graphical information. The IMAT Graphics Manual shows users of commercial analysis codes (MATRIXx, MSC/NASTRAN and I-DEAS) how to use the IMAT graphics system to obtain high quality graphical output using familiar plotting procedures. The manual explains the key features of the IMAT graphics system, illustrates their use with simple step-by-step examples, and provides a reference for users who wish to take advantage of the flexibility of the software to customize their own applications.
Purification of Proteins Fused to Maltose-Binding Protein.
Lebendiker, Mario; Danieli, Tsafi
2017-01-01
Maltose-Binding Protein (MBP) is one of the most popular fusion partners being used for producing recombinant proteins in bacterial cells. MBP allows the use of a simple capture affinity step on Amylose-Agarose or Dextrin-Sepharose columns, resulting in a protein that is often 70-90 % pure in a single step. In addition to protein isolation applications, MBP provides a high degree of translation, and facilitates the proper folding and solubility of the target protein. This paper describes efficient procedures for isolating highly purified MBP target proteins. Special attention is given to considerations for downstream applications such as structural determination studies, protein activity assays, and assessing the chemical characteristics of the target protein.
New Method for Evaluation of Virucidal Activity of Antiseptics and Disinfectants
Papageorgiou, Georgios T.; Mocé-Llivina, Laura; Jofre, Juan
2001-01-01
Counting culturable viruses adsorbed to cellulose nitrate filters (the VIRADEN method) is proposed as a simple procedure for the evaluation of the virucidal activity of antiseptics and disinfectants. The virucidal activities of two different doses of iodine, chlorine, glutaraldehyde, and chlorhexidine digluconate on poliovirus 1 were tested with a standardized procedure and with the VIRADEN method. The two procedures assayed provided similar results. PMID:11722944
16 CFR 1610.6 - Test procedure.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test procedure. 1610.6 Section 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...
16 CFR 1610.6 - Test procedure.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Test procedure. 1610.6 Section 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...
16 CFR 1610.6 - Test procedure.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test procedure. 1610.6 Section 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...
Processing of zero-derived words in English: an fMRI investigation.
Pliatsikas, Christos; Wheeldon, Linda; Lahiri, Aditi; Hansen, Peter C
2014-01-01
Derivational morphological processes allow us to create new words (e.g. punish (V) to noun (N) punishment) from base forms. The number of steps from the basic units to derived words often varies (e.g., nationality
Computation of the dipole moments of proteins.
Antosiewicz, J
1995-10-01
A simple and computationally feasible procedure for the calculation of net charges and dipole moments of proteins at arbitrary pH and salt conditions is described. The method is intended to provide data that may be compared to the results of transient electric dichroism experiments on protein solutions. The procedure consists of three major steps: (i) calculation of self energies and interaction energies for ionizable groups in the protein by using the finite-difference Poisson-Boltzmann method, (ii) determination of the position of the center of diffusion (to which the calculated dipole moment refers) and the extinction coefficient tensor for the protein, and (iii) generation of the equilibrium distribution of protonation states of the protein by a Monte Carlo procedure, from which mean and root-mean-square dipole moments and optical anisotropies are calculated. The procedure is applied to 12 proteins. It is shown that it gives hydrodynamic and electrical parameters for proteins in good agreement with experimental data.
Renault, Emmanuel; Barbat-Rogeon, Aline; Chaleix, Vincent; Calliste, Claude-Alain; Colas, Cyril; Gloaguen, Vincent
2014-09-01
4-O-Methylglucuronoxylans (MGX) were isolated from chestnut wood sawdust using two different procedures: chlorite delignification followed by the classical alkaline extraction step, and an unusual green chemistry process of delignification using phthalocyanine/H2O2 followed by a simple extraction with hot water. Antioxidant properties of both MGX were evaluated against the stable radical 2,2-diphenyl-1-picrylhydrazyl (DPPH) by electronic spin resonance (ESR). IC50 of water-extracted MGX was found to be less than 225 μg mL(-1), in contrast with alkali-extracted MGX for which no radical scavenging was observed. Characterization of extracts by colorimetric assay, GC, LC-MS and NMR spectroscopy provided some clues to understanding structure-function relationships of MGX in connection with their antioxidant activity. Copyright © 2014 Elsevier B.V. All rights reserved.
Zinchenko, Anatoly; Taki, Yosuke; Sergeyev, Vladimir G.; Murata, Shizuaki
2015-01-01
A simple method for preparation of DNA-carbon nanotubes hybrid hydrogel based on a two-step procedure including: (i) solubilization of multi-walled carbon nanotubes (MWCNT) in aqueous solution of DNA, and (ii) chemical cross-linking between solubilized MWCNT via adsorbed DNA and free DNA by ethylene glycol diglycidyl ether is reported. We show that there exists a critical concentration of MWCNT below which a homogeneous dispersion of MWCNT in hybrid hydrogel can be achieved, while at higher concentrations of MWCNT the aggregation of MWCNT inside hydrogel occurs. The strengthening effect of carbon nanotube in the process of hydrogel shrinking in solutions with high salt concentration was demonstrated and significant passivation of MWCNT adsorption properties towards low-molecular-weight aromatic binders due to DNA adsorption on MWCNT surface was revealed. PMID:28347011
Zinchenko, Anatoly; Taki, Yosuke; Sergeyev, Vladimir G; Murata, Shizuaki
2015-03-03
A simple method for preparation of DNA-carbon nanotubes hybrid hydrogel based on a two-step procedure including: (i) solubilization of multi-walled carbon nanotubes (MWCNT) in aqueous solution of DNA, and (ii) chemical cross-linking between solubilized MWCNT via adsorbed DNA and free DNA by ethylene glycol diglycidyl ether is reported. We show that there exists a critical concentration of MWCNT below which a homogeneous dispersion of MWCNT in hybrid hydrogel can be achieved, while at higher concentrations of MWCNT the aggregation of MWCNT inside hydrogel occurs. The strengthening effect of carbon nanotube in the process of hydrogel shrinking in solutions with high salt concentration was demonstrated and significant passivation of MWCNT adsorption properties towards low-molecular-weight aromatic binders due to DNA adsorption on MWCNT surface was revealed.
Deep generative learning for automated EHR diagnosis of traditional Chinese medicine.
Liang, Zhaohui; Liu, Jun; Ou, Aihua; Zhang, Honglai; Li, Ziping; Huang, Jimmy Xiangji
2018-05-04
Computer-aided medical decision-making (CAMDM) is the method to utilize massive EMR data as both empirical and evidence support for the decision procedure of healthcare activities. Well-developed information infrastructure, such as hospital information systems and disease surveillance systems, provides abundant data for CAMDM. However, the complexity of EMR data with abstract medical knowledge makes the conventional model incompetent for the analysis. Thus a deep belief networks (DBN) based model is proposed to simulate the information analysis and decision-making procedure in medical practice. The purpose of this paper is to evaluate a deep learning architecture as an effective solution for CAMDM. A two-step model is applied in our study. At the first step, an optimized seven-layer deep belief network (DBN) is applied as an unsupervised learning algorithm to perform model training to acquire feature representation. Then a support vector machine model is adopted to DBN at the second step of the supervised learning. There are two data sets used in the experiments. One is a plain text data set indexed by medical experts. The other is a structured dataset on primary hypertension. The data are randomly divided to generate the training set for the unsupervised learning and the testing set for the supervised learning. The model performance is evaluated by the statistics of mean and variance, the average precision and coverage on the data sets. Two conventional shallow models (support vector machine / SVM and decision tree / DT) are applied as the comparisons to show the superiority of our proposed approach. The deep learning (DBN + SVM) model outperforms simple SVM and DT on two data sets in terms of all the evaluation measures, which confirms our motivation that the deep model is good at capturing the key features with less dependence when the index is built up by manpower. Our study shows the two-step deep learning model achieves high performance for medical information retrieval over the conventional shallow models. It is able to capture the features of both plain text and the highly-structured database of EMR data. The performance of the deep model is superior to the conventional shallow learning models such as SVM and DT. It is an appropriate knowledge-learning model for information retrieval of EMR system. Therefore, deep learning provides a good solution to improve the performance of CAMDM systems. Copyright © 2018. Published by Elsevier B.V.
A Novel Two-Step Method for Screening Shade Tolerant Mutant Plants via Dwarfism
Li, Wei; Katin-Grazzini, Lorenzo; Krishnan, Sanalkumar; Thammina, Chandra; El-Tanbouly, Rania; Yer, Huseyin; Merewitz, Emily; Guillard, Karl; Inguagiato, John; McAvoy, Richard J.; Liu, Zongrang; Li, Yi
2016-01-01
When subjected to shade, plants undergo rapid shoot elongation, which often makes them more prone to disease and mechanical damage. Shade-tolerant plants can be difficult to breed; however, they offer a substantial benefit over other varieties in low-light areas. Although perennial ryegrass (Lolium perenne L.) is a popular species of turf grasses because of their good appearance and fast establishment, the plant normally does not perform well under shade conditions. It has been reported that, in turfgrass, induced dwarfism can enhance shade tolerance. Here we describe a two-step procedure for isolating shade tolerant mutants of perennial ryegrass by first screening for dominant dwarf mutants, and then screening dwarf plants for shade tolerance. The two-step screening process to isolate shade tolerant mutants can be done efficiently with limited space at early seedling stages, which enables quick and efficient isolation of shade tolerant mutants, and thus facilitates development of shade tolerant new cultivars of turfgrasses. Using the method, we isolated 136 dwarf mutants from 300,000 mutagenized seeds, with 65 being shade tolerant (0.022%). When screened directly for shade tolerance, we recovered only four mutants from a population of 150,000 (0.003%) mutagenized seeds. One shade tolerant mutant, shadow-1, was characterized in detail. In addition to dwarfism, shadow-1 and its sexual progeny displayed high degrees of tolerance to both natural and artificial shade. We showed that endogenous gibberellin (GA) content in shadow-1 was higher than wild-type controls, and shadow-1 was also partially GA insensitive. Our novel, simple and effective two-step screening method should be applicable to breeding shade tolerant cultivars of turfgrasses, ground covers, and other economically important crop plants that can be used under canopies of existing vegetation to increase productivity per unit area of land. PMID:27752260
A Pearson Random Walk with Steps of Uniform Orientation and Dirichlet Distributed Lengths
NASA Astrophysics Data System (ADS)
Le Caër, Gérard
2010-08-01
A constrained diffusive random walk of n steps in ℝ d and a random flight in ℝ d , which are equivalent, were investigated independently in recent papers (J. Stat. Phys. 127:813, 2007; J. Theor. Probab. 20:769, 2007, and J. Stat. Phys. 131:1039, 2008). The n steps of the walk are independent and identically distributed random vectors of exponential length and uniform orientation. Conditioned on the sum of their lengths being equal to a given value l, closed-form expressions for the distribution of the endpoint of the walk were obtained altogether for any n for d=1,2,4. Uniform distributions of the endpoint inside a ball of radius l were evidenced for a walk of three steps in 2D and of two steps in 4D. The previous walk is generalized by considering step lengths which have independent and identical gamma distributions with a shape parameter q>0. Given the total walk length being equal to 1, the step lengths have a Dirichlet distribution whose parameters are all equal to q. The walk and the flight above correspond to q=1. Simple analytical expressions are obtained for any d≥2 and n≥2 for the endpoint distributions of two families of walks whose q are integers or half-integers which depend solely on d. These endpoint distributions have a simple geometrical interpretation. Expressed for a two-step planar walk whose q=1, it means that the distribution of the endpoint on a disc of radius 1 is identical to the distribution of the projection on the disc of a point M uniformly distributed over the surface of the 3D unit sphere. Five additional walks, with a uniform distribution of the endpoint in the inside of a ball, are found from known finite integrals of products of powers and Bessel functions of the first kind. They include four different walks in ℝ3, two of two steps and two of three steps, and one walk of two steps in ℝ4. Pearson-Liouville random walks, obtained by distributing the total lengths of the previous Pearson-Dirichlet walks according to some specified probability law are finally discussed. Examples of unconstrained random walks, whose step lengths are gamma distributed, are more particularly considered.
An avian model for the reversal of neurobehavioral teratogenicity with neural stem cells
Dotan, Sharon; Pinkas, Adi; Slotkin, Theodore A.; Yanai, Joseph
2010-01-01
A fast and simple model which uses lower animals on the evolutionary scale is beneficial for developing procedures for the reversal of neurobehavioral teratogenicity with neural stem cells. Here, we established a procedure for the derivation of chick neural stem cells, establishing embryonic day (E) 10 as optimal for progression to neuronal phenotypes. Cells were obtained from the embryonic cerebral hemispheres and incubated for 5–7 days in enriched medium containing epidermal growth factor (EGF) and basic fibroblast growth factor (FGF2) according to a procedure originally developed for mice. A small percentage of the cells survived, proliferated and formed nestin-positive neurospheres. After removal of the growth factors to allow differentiation (5 days), 74% of the cells differentiated into all major lineages of the nervous system, including neurons (Beta III tubulin-positive, 54% of the total number of differentiated cells), astrocytes (GFAP-positive, 26%), and oligodendrocytes (O4-positive, 20%). These findings demonstrate that the cells were indeed neural stem cells. Next, the cells were transplanted in two allograft chick models; (1) direct cerebral transplantation to 24-hours-old chicks, followed by post-transplantation cell tracking at 24 hours, 6 days and 14 days, and (2) intravenous transplantation to chick embryos on E13, followed by cell tracking on E19. With both methods, transplanted cells were found in the brain. The chick embryo provides a convenient, precisely-timed and unlimited supply of neural progenitors for therapy by transplantation, as well as constituting a fast and simple model in which to evaluate the ability of neural stem cell transplantation to repair neural damage, steps that are critical for progress toward therapeutic applications. PMID:20211723
Brion, F; Rogerieux, F; Noury, P; Migeon, B; Flammarion, P; Thybaud, E; Porcher, J M
2000-01-14
A two-step purification protocol was developed to purify rainbow trout (Oncorhynchus mykiss) vitellogenin (Vtg) and was successfully applied to Vtg of chub (Leuciscus cephalus) and gudgeon (Gobio gobio). Capture and intermediate purification were performed by anion-exchange chromatography on a Resource Q column and a polishing step was performed by gel permeation chromatography on Superdex 200 column. This method is a rapid two-step purification procedure that gave a pure solution of Vtg as assessed by silver staining electrophoresis and immunochemical characterisation.
NASA Astrophysics Data System (ADS)
Wan, Hui; Zhang, Kai; Rasch, Philip J.; Singh, Balwinder; Chen, Xingyuan; Edwards, Jim
2017-02-01
A test procedure is proposed for identifying numerically significant solution changes in evolution equations used in atmospheric models. The test issues a fail
signal when any code modifications or computing environment changes lead to solution differences that exceed the known time step sensitivity of the reference model. Initial evidence is provided using the Community Atmosphere Model (CAM) version 5.3 that the proposed procedure can be used to distinguish rounding-level solution changes from impacts of compiler optimization or parameter perturbation, which are known to cause substantial differences in the simulated climate. The test is not exhaustive since it does not detect issues associated with diagnostic calculations that do not feedback to the model state variables. Nevertheless, it provides a practical and objective way to assess the significance of solution changes. The short simulation length implies low computational cost. The independence between ensemble members allows for parallel execution of all simulations, thus facilitating fast turnaround. The new method is simple to implement since it does not require any code modifications. We expect that the same methodology can be used for any geophysical model to which the concept of time step convergence is applicable.
Specific arithmetic calculation deficits in children with Turner syndrome.
Rovet, J; Szekely, C; Hockenberry, M N
1994-12-01
Study 1 compared arithmetic processing skills on the WRAT-R in 45 girls with Turner syndrome (TS) and 92 age-matched female controls. Results revealed significant underachievement by subjects with TS, which reflected their poorer performance on problems requiring the retrieval of addition and multiplication facts and procedural knowledge for addition and division operations. TS subjects did not differ qualitatively from controls in type of procedural error committed. Study 2, which compared the performance of 10 subjects with TS and 31 controls on the Keymath Diagnostic Arithmetic Test, showed that the TS group had less adequate knowledge of arithmetic, subtraction, and multiplication procedures but did not differ from controls on Fact items. Error analyses revealed that TS subjects were more likely to confuse component steps or fail to separate intermediate steps or to complete problems. TS subjects relied to a greater degree on verbal than visual-spatial abilities in arithmetic processing while their visual-spatial abilities were associated with retrieval of simple multidigit addition facts and knowledge of subtraction, multiplication, and division procedures. Differences between the TS and control groups increased with age for Keymath, but not WRAT-R, procedures. Discrepant findings are related to the different task constraints (timed vs. untimed, single vs. alternate versions, size of item pool) and the use of different strategies (counting vs. fact retrieval). It is concluded that arithmetic difficulties in females with TS are due to less adequate procedural skills, combined with poorer fact retrieval in timed testing situations, rather than to inadequate visual-spatial abilities.
Technical Note: Procedure for the calibration and validation of kilo-voltage cone-beam CT models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vilches-Freixas, Gloria; Létang, Jean Michel; Rit,
2016-09-15
Purpose: The aim of this work is to propose a general and simple procedure for the calibration and validation of kilo-voltage cone-beam CT (kV CBCT) models against experimental data. Methods: The calibration and validation of the CT model is a two-step procedure: the source model then the detector model. The source is described by the direction dependent photon energy spectrum at each voltage while the detector is described by the pixel intensity value as a function of the direction and the energy of incident photons. The measurements for the source consist of a series of dose measurements in air performedmore » at each voltage with varying filter thicknesses and materials in front of the x-ray tube. The measurements for the detector are acquisitions of projection images using the same filters and several tube voltages. The proposed procedure has been applied to calibrate and assess the accuracy of simple models of the source and the detector of three commercial kV CBCT units. If the CBCT system models had been calibrated differently, the current procedure would have been exclusively used to validate the models. Several high-purity attenuation filters of aluminum, copper, and silver combined with a dosimeter which is sensitive to the range of voltages of interest were used. A sensitivity analysis of the model has also been conducted for each parameter of the source and the detector models. Results: Average deviations between experimental and theoretical dose values are below 1.5% after calibration for the three x-ray sources. The predicted energy deposited in the detector agrees with experimental data within 4% for all imaging systems. Conclusions: The authors developed and applied an experimental procedure to calibrate and validate any model of the source and the detector of a CBCT unit. The present protocol has been successfully applied to three x-ray imaging systems. The minimum requirements in terms of material and equipment would make its implementation suitable in most clinical environments.« less
A new methodology to determine kinetic parameters for one- and two-step chemical models
NASA Technical Reports Server (NTRS)
Mantel, T.; Egolfopoulos, F. N.; Bowman, C. T.
1996-01-01
In this paper, a new methodology to determine kinetic parameters for simple chemical models and simple transport properties classically used in DNS of premixed combustion is presented. First, a one-dimensional code is utilized to performed steady unstrained laminar methane-air flame in order to verify intrinsic features of laminar flames such as burning velocity and temperature and concentration profiles. Second, the flame response to steady and unsteady strain in the opposed jet configuration is numerically investigated. It appears that for a well determined set of parameters, one- and two-step mechanisms reproduce the extinction limit of a laminar flame submitted to a steady strain. Computations with the GRI-mech mechanism (177 reactions, 39 species) and multicomponent transport properties are used to validate these simplified models. A sensitivity analysis of the preferential diffusion of heat and reactants when the Lewis number is close to unity indicates that the response of the flame to an oscillating strain is very sensitive to this number. As an application of this methodology, the interaction between a two-dimensional vortex pair and a premixed laminar flame is performed by Direct Numerical Simulation (DNS) using the one- and two-step mechanisms. Comparison with the experimental results of Samaniego et al. (1994) shows a significant improvement in the description of the interaction when the two-step model is used.
[Half-gloving cordectomy: a modified procedure for concealed penis].
Sun, Wei-Gui; Zheng, Qi-Chuan; Jiang, Kun
2012-06-01
To search for a simple surgical procedure for the treatment of concealed penis that may have better effect and less complications. We used a modified surgical method in the treatment of 58 patients with concealed penis aged from 3 to 15 (mean 6.8) years. The operation was simplified and involved the following steps: wholly unveiling the penis glans, half-degloving the foreskins, cutting off all the adhesive fibers up to the penile suspensory ligaments, and liberating the external penis. The operation was successful in all the patients, with the operative time of 15 -45 (mean 33) minutes, hospital stay of 2 - 5 (mean 3.5) days, but no complications except mild foreskin edema in 5 cases. The external penis was prolonged from 0.5 - 2.8 (mean 1.4) cm preoperatively to 3.2 - 8.5 (mean 3.9) cm postoperatively. The patients were followed up for 1 -3 years, all satisfied with the length and appearance of the penis, and their sexual and reproductive functions were normal. The modified surgical procedure for concealed penis is simple and effective, with desirable outcomes, few postoperative complications and no damage to sexual and reproductive functions.
Parameter estimation for terrain modeling from gradient data. [navigation system for Martian rover
NASA Technical Reports Server (NTRS)
Dangelo, K. R.
1974-01-01
A method is developed for modeling terrain surfaces for use on an unmanned Martian roving vehicle. The modeling procedure employs a two-step process which uses gradient as well as height data in order to improve the accuracy of the model's gradient. Least square approximation is used in order to stochastically determine the parameters which describe the modeled surface. A complete error analysis of the modeling procedure is included which determines the effect of instrumental measurement errors on the model's accuracy. Computer simulation is used as a means of testing the entire modeling process which includes the acquisition of data points, the two-step modeling process and the error analysis. Finally, to illustrate the procedure, a numerical example is included.
A simple, compact, and rigid piezoelectric step motor with large step size.
Wang, Qi; Lu, Qingyou
2009-08-01
We present a novel piezoelectric stepper motor featuring high compactness, rigidity, simplicity, and any direction operability. Although tested in room temperature, it is believed to work in low temperatures, owing to its loose operation conditions and large step size. The motor is implemented with a piezoelectric scanner tube that is axially cut into almost two halves and clamp holds a hollow shaft inside at both ends via the spring parts of the shaft. Two driving voltages that singly deform the two halves of the piezotube in one direction and recover simultaneously will move the shaft in the opposite direction, and vice versa.
A simple, compact, and rigid piezoelectric step motor with large step size
NASA Astrophysics Data System (ADS)
Wang, Qi; Lu, Qingyou
2009-08-01
We present a novel piezoelectric stepper motor featuring high compactness, rigidity, simplicity, and any direction operability. Although tested in room temperature, it is believed to work in low temperatures, owing to its loose operation conditions and large step size. The motor is implemented with a piezoelectric scanner tube that is axially cut into almost two halves and clamp holds a hollow shaft inside at both ends via the spring parts of the shaft. Two driving voltages that singly deform the two halves of the piezotube in one direction and recover simultaneously will move the shaft in the opposite direction, and vice versa.
Old and New Techniques as a Safe Hybrid Approach for Carotid Tandem Lesions.
Barillà, David; Massara, Mafalda; Alberti, Antonino; Volpe, Alberto; Cutrupi, Andrea; Versace, Paolo; Volpe, Pietro
2016-04-01
Carotid revascularization is performed to prevent stroke. Carotid tandem lesions represent a challenge for treatment, and a hybrid approach may result effective. A high-risk 65-year-old woman presented with a "tandem lesion" of left common and internal carotid artery. She was deemed unfit for "simple" standard carotid endarterectomy (CEA). A "single-step" safe hybrid procedure was scheduled for the patient. A "Cormier" carotid vein graft bypass with a retrograde stenting was performed under local anesthesia. The "safe hybrid procedure" for tandem lesions of the common and internal carotid artery is effective and suitable in high-risk patients in a high-volume centers. Copyright © 2016 Elsevier Inc. All rights reserved.
Ehlhardt, L A; Sohlberg, M M; Glang, A; Albin, R
2005-08-10
The purpose of this pilot study was to evaluate an instructional package that facilitates learning and retention of multi-step procedures for persons with severe memory and executive function impairments resulting from traumatic brain injury. The study used a multiple baseline across participants design. Four participants, two males and two females, ranging in age from 36-58 years, were taught a 7-step e-mail task. The instructional package (TEACH-M) was the experimental intervention and the number of correct e-mail steps learned was the dependent variable. Treatment effects were replicated across the four participants and maintained at 30 days post-treatment. Generalization and social validity data further supported the treatment programme. The results suggest that individuals with severe cognitive impairments are capable of learning new skills. Directions for future research include application of the instructional package to other multi-step procedures.
Systematic procedure for designing processes with multiple environmental objectives.
Kim, Ki-Joo; Smith, Raymond L
2005-04-01
Evaluation of multiple objectives is very important in designing environmentally benign processes. It requires a systematic procedure for solving multiobjective decision-making problems due to the complex nature of the problems, the need for complex assessments, and the complicated analysis of multidimensional results. In this paper, a novel systematic procedure is presented for designing processes with multiple environmental objectives. This procedure has four steps: initialization, screening, evaluation, and visualization. The first two steps are used for systematic problem formulation based on mass and energy estimation and order of magnitude analysis. In the third step, an efficient parallel multiobjective steady-state genetic algorithm is applied to design environmentally benign and economically viable processes and to provide more accurate and uniform Pareto optimal solutions. In the last step a new visualization technique for illustrating multiple objectives and their design parameters on the same diagram is developed. Through these integrated steps the decision-maker can easily determine design alternatives with respect to his or her preferences. Most importantly, this technique is independent of the number of objectives and design parameters. As a case study, acetic acid recovery from aqueous waste mixtures is investigated by minimizing eight potential environmental impacts and maximizing total profit. After applying the systematic procedure, the most preferred design alternatives and their design parameters are easily identified.
Adali, M Kemal; Uzun, Cem
2005-09-01
The aim of the present study is to evaluate the effect of swallowing type (dry versus wet) on the outcome of a nine-step inflation/deflation tympanometric Eustachian tube function (ETF) test in healthy adults. Fourteen normal healthy volunteers, between 19 and 28 years of age, were included in the study. The nine-step test was performed in two different test procedures: (1) test with dry swallows (dry test procedure) and (2) test with liquid swallows (wet test procedure). If the equilibration of middle-ear (ME) pressure was successful in all the steps of the nine-step test, ETF was considered 'Good'. Otherwise, the test was considered 'Poor', and the test was repeated at a second session. In the dry test procedure, ETF was 'Good' in 21 ears at the first session and in 24 ears after the second session (p > 0.05). However, in the wet test procedure, ETF was 'Good' in 13 ears at the first session and in 21 ears after the second session (p < 0.05). At the first session, ETF was 'Good' in 21 and 13 ears in the dry and wet test procedures, respectively. The difference was statistically significant (p < 0.05). However, after the second session, the overall number of ears with 'Good' tubal function was almost the same in both test procedures (24 ears at dry test procedures versus 21 ears at wet test procedures;p > 0.05). Dry swallowing seems to be more effective for the equilibration of ME pressure. Thus, a single-session dependent evaluation of ETF may be efficient for the dry test procedure of the nine-step test. Swallowing with water may be easier for subjects, but a repetition of the test at a second session may be necessary when the test result is 'Poor'.
SERE: single-parameter quality control and sample comparison for RNA-Seq.
Schulze, Stefan K; Kanwar, Rahul; Gölzenleuchter, Meike; Therneau, Terry M; Beutler, Andreas S
2012-10-03
Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson's correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson's r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen's simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter.
SERE: Single-parameter quality control and sample comparison for RNA-Seq
2012-01-01
Background Assessing the reliability of experimental replicates (or global alterations corresponding to different experimental conditions) is a critical step in analyzing RNA-Seq data. Pearson’s correlation coefficient r has been widely used in the RNA-Seq field even though its statistical characteristics may be poorly suited to the task. Results Here we present a single-parameter test procedure for count data, the Simple Error Ratio Estimate (SERE), that can determine whether two RNA-Seq libraries are faithful replicates or globally different. Benchmarking shows that the interpretation of SERE is unambiguous regardless of the total read count or the range of expression differences among bins (exons or genes), a score of 1 indicating faithful replication (i.e., samples are affected only by Poisson variation of individual counts), a score of 0 indicating data duplication, and scores >1 corresponding to true global differences between RNA-Seq libraries. On the contrary the interpretation of Pearson’s r is generally ambiguous and highly dependent on sequencing depth and the range of expression levels inherent to the sample (difference between lowest and highest bin count). Cohen’s simple Kappa results are also ambiguous and are highly dependent on the choice of bins. For quantifying global sample differences SERE performs similarly to a measure based on the negative binomial distribution yet is simpler to compute. Conclusions SERE can therefore serve as a straightforward and reliable statistical procedure for the global assessment of pairs or large groups of RNA-Seq datasets by a single statistical parameter. PMID:23033915
NASA Astrophysics Data System (ADS)
Zhao, Yong; Chen, Mao-qing; Xia, Feng; Hu, Hai-feng
2017-11-01
A novel refractive index (RI) sensor based on an asymmetrical Mach-Zehnder interferometer (MZI) with two different step-like tapers is proposed. The step-like taper is fabricated by fusion splicing two half tapers with an appropriate offset. By further applying offset and discharging to the last fabricated step-like taper of MZI, influence of taper parameters on interference spectrum is investigated using only one device. This simple technique provides an on-line method to sweep parameters of step-like tapers and speeds up the optimization process of interference spectrum, meanwhile. In RI sensing experiment, the sensor has a high sensitivity of -185.79 nm/RIU (refractive index unit) in the RI range of 1.3333-1.3673.
Electrostatic design of protein-protein association rates.
Schreiber, Gideon; Shaul, Yossi; Gottschalk, Kay E
2006-01-01
De novo design and redesign of proteins and protein complexes have made promising progress in recent years. Here, we give an overview of how to use available computer-based tools to design proteins to bind faster and tighter to their protein-complex partner by electrostatic optimization between the two proteins. Electrostatic optimization is possible because of the simple relation between the Debye-Huckel energy of interaction between a pair of proteins and their rate of association. This can be used for rapid, structure-based calculations of the electrostatic attraction between the two proteins in the complex. Using these principles, we developed two computer programs that predict the change in k(on), and as such the affinity, on introducing charged mutations. The two programs have a web interface that is available at
[Ladder step strategy for surgical repair of congenital concealed penis in children].
Wang, Fu-Ran; Zhong, Hong-Ji; Chen, Yi; Zhao, Jun-Feng; Li, Yan
2016-11-01
To assess the feasibility of the ladder step strategy in surgical repair of congenital concealed penis in children. This study included 52 children with congenital concealed penis treated in the past two years by surgical repair using the ladder step strategy, which consists of five main steps: cutting the narrow ring of the foreskin, degloving the penile skin, fixing the penile skin at the base, covering the penile shaft, and reshaping the prepuce. The perioperative data of the patients were prospectively collected and statistically described. Of the 52 patients, 20 needed remodeling of the frenulum and 27 received longitudinal incision in the penoscrotal junction to expose and deglove the penile shaft. The advanced scrotal flap technique was applied in 8 children to cover the penile shaft without tension, the pedicled foreskin flap technique employed in 11 to repair the penile skin defect, and excision of the webbed skin of the ventral penis performed in another 44 to remodel the penoscrotal angle. The operation time, blood loss, and postoperative hospital stay were 40-100 minutes, 5-30 ml, and 3-6 days, respectively. Wound bleeding and infection occurred in 1 and 5 cases, respectively. Follow-up examinations at 3 and 6 months after surgery showed that all the children had a satisfactory penile appearance except for some minor complications (2 cases of penile retraction, 2 cases of redundant ventral skin, and 1 case of iatrogenic penile curvature). The ladder step strategy for surgical repair of congenital concealed penis in children is a simple procedure with minor injury and satisfactory appearance of the penis.
DOT National Transportation Integrated Search
2006-01-01
A previous study developed a procedure for microscopic simulation model calibration and validation and evaluated the procedure via two relatively simple case studies using three microscopic simulation models. Results showed that default parameters we...
The Role of the Global SOF Network in a Resource Constrained Environment
2013-11-01
backed by actions. Step Two: Matching Skill Sets with Individuals: Who Needs to Know What? This step sounds simple enough in theory . You need to...Training Finally, step five is the recognition that, like physical training and condition- ing, cognitive skills need to be continuously refreshed. These...and maintaining the data needed , and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other
47 CFR 80.319 - Radiotelegraph distress call and message transmission procedure.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., when time is vital, the first and second steps may be omitted. These two steps of the distress... transmissions under paragraphs (a) (5) and (6) of this section, which are to permit direction finding stations...
47 CFR 80.319 - Radiotelegraph distress call and message transmission procedure.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., when time is vital, the first and second steps may be omitted. These two steps of the distress... transmissions under paragraphs (a) (5) and (6) of this section, which are to permit direction finding stations...
47 CFR 80.319 - Radiotelegraph distress call and message transmission procedure.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., when time is vital, the first and second steps may be omitted. These two steps of the distress... transmissions under paragraphs (a) (5) and (6) of this section, which are to permit direction finding stations...
47 CFR 80.319 - Radiotelegraph distress call and message transmission procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., when time is vital, the first and second steps may be omitted. These two steps of the distress... transmissions under paragraphs (a) (5) and (6) of this section, which are to permit direction finding stations...
47 CFR 80.319 - Radiotelegraph distress call and message transmission procedure.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., when time is vital, the first and second steps may be omitted. These two steps of the distress... transmissions under paragraphs (a) (5) and (6) of this section, which are to permit direction finding stations...
Simple Psychological Interventions for Reducing Pain From Common Needle Procedures in Adults
Boerner, Katelynn E.; Birnie, Kathryn A.; Taddio, Anna; McMurtry, C. Meghan; Noel, Melanie; Shah, Vibhuti; Pillai Riddell, Rebecca
2015-01-01
Background: This systematic review evaluated the effectiveness of simple psychological interventions for managing pain and fear in adults undergoing vaccination or related common needle procedures (ie, venipuncture/venous cannulation). Design/Methods: Databases were searched to identify relevant randomized and quasi-randomized controlled trials. Self-reported pain and fear were prioritized as critically important outcomes. Data were combined using standardized mean difference (SMD) or relative risk (RR) with 95% confidence intervals (CI). Results: No studies involving vaccination met inclusion criteria; evidence was drawn from 8 studies of other common needle procedures (eg, venous cannulation, venipuncture) in adults. Two trials evaluating the impact of neutral signaling of the impending procedure (eg, “ready?”) as compared with signaling of impending pain (eg, “sharp scratch”) demonstrated lower pain when signaled about the procedure (n=199): SMD=−0.97 (95% CI, −1.26, −0.68), after removal of 1 trial where self-reported pain was significantly lower than the other 2 included trials. Two trials evaluated music distraction (n=156) and demonstrated no difference in pain: SMD=0.10 (95% CI, −0.48, 0.27), or fear: SMD=−0.25 (95% CI, −0.61, 0.10). Two trials evaluated visual distraction and demonstrated no difference in pain (n=177): SMD=−0.57 (95% CI, −1.82, 0.68), or fear (n=81): SMD=−0.05 (95% CI, −0.50, 0.40). Two trials evaluating breathing interventions found less pain in intervention groups (n=138): SMD=−0.82 (95% CI, −1.21, −0.43). The quality of evidence across all trials was very low. Conclusions: There are no published studies of simple psychological interventions for vaccination pain in adults. There is some evidence of a benefit from other needle procedures for breathing strategies and neutral signaling of the start of the procedure. There is no evidence for use of music or visual distraction. PMID:26352921
NASA Technical Reports Server (NTRS)
Sucec, J.
1975-01-01
Solutions for the surface temperature and surface heat flux are found for laminar, constant property, slug flow over a plate convectively cooled from below, when the temperature of the fluid over the plate varies arbitrarily with time at the plate leading edge. A simple technique is presented for handling arbitrary fluid temperature variation with time by approximating it by a sequence of ramps or steps for which exact analytical solutions are available.
Keller, T; Schneider, A; Regenscheit, P; Dirnhofer, R; Rücker, T; Jaspers, J; Kisser, W
1999-01-11
A new method has been developed for the rapid analysis of psilocybin and/or psilocin in fungus material using ion mobility spectrometry. Quantitative analysis was performed by gas chromatography-mass spectrometry after a simple one-step extraction involving homogenization of the dried fruit bodies of fungi in chloroform and derivatization with MSTFA. The proposed methods resulted in rapid procedures useful in analyzing psychotropic fungi for psilocybin and psilocin.
Methodology of the Westinghouse dynamic rod worth measurement technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chao, Y.A.; Chapman, D.M.; Easter, M.E.
1992-01-01
During zero-power physics testing, plant operations personnel use one of various techniques to measure the reactivity worth of the control rods to confirm shutdown margin. A simple and fast procedure for measuring rod worths called dynamic rod worth measurement (DRWM) has been developed at Westinghouse. This procedure was tested at the recent startups of Point Beach Nuclear Power Plant Unit 1 cycle 20 and Unit 2 cycle 18. The results of these tests show that DRWM measures rod worths with accuracy comparable to that of both boron dilution and rod bank exchange measurements. The DRWM procedure is a fast processmore » of measuring the reactivity worth of individual banks by inserting and withdrawing the bank continuously at the maximum stepping speed without changing the boron concentration and recording the signals of the ex-core detectors.« less
A preliminary report on the rapid fluorimetric determination of uranium in low-grade ores
Grimaldi, F.S.; Levine, Harry
1950-01-01
A simple and very rapid fluorimetric procedure is described for the determination of uranium in low-grade shale and phosphate ores. The best working range is from 0.001 to about 0.04 percent U. The procedure employs batch extraction of uranium nitrate by ethyl acetate, using aluminum nitrate as the salting agent, prior to the visual fluorimetric estimation. The procedure is especially designed to save reagents; only 9.5 g of aluminum nitrate and 10 ml of ethyl acetate being used for one analysis. The solution of the sample by means of a fusion with NaOH-NaNO3 flux is rapid. After fusion the sample is immediately extracted without removing silica and other hydrolytic precipitates. Aluminum nitrate very effectively ties up fluoride and phosphate, thus eliminating steps required for their removal.
Determination of Total Carbohydrates in Algal Biomass: Laboratory Analytical Procedure (LAP)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Wychen, Stefanie; Laurens, Lieve M. L.
This procedure uses two-step sulfuric acid hydrolysis to hydrolyze the polymeric forms of carbohydrates in algal biomass into monomeric subunits. The monomers are then quantified by either HPLC or a suitable spectrophotometric method.
Molgenis-impute: imputation pipeline in a box.
Kanterakis, Alexandros; Deelen, Patrick; van Dijk, Freerk; Byelas, Heorhiy; Dijkstra, Martijn; Swertz, Morris A
2015-08-19
Genotype imputation is an important procedure in current genomic analysis such as genome-wide association studies, meta-analyses and fine mapping. Although high quality tools are available that perform the steps of this process, considerable effort and expertise is required to set up and run a best practice imputation pipeline, particularly for larger genotype datasets, where imputation has to scale out in parallel on computer clusters. Here we present MOLGENIS-impute, an 'imputation in a box' solution that seamlessly and transparently automates the set up and running of all the steps of the imputation process. These steps include genome build liftover (liftovering), genotype phasing with SHAPEIT2, quality control, sample and chromosomal chunking/merging, and imputation with IMPUTE2. MOLGENIS-impute builds on MOLGENIS-compute, a simple pipeline management platform for submission and monitoring of bioinformatics tasks in High Performance Computing (HPC) environments like local/cloud servers, clusters and grids. All the required tools, data and scripts are downloaded and installed in a single step. Researchers with diverse backgrounds and expertise have tested MOLGENIS-impute on different locations and imputed over 30,000 samples so far using the 1,000 Genomes Project and new Genome of the Netherlands data as the imputation reference. The tests have been performed on PBS/SGE clusters, cloud VMs and in a grid HPC environment. MOLGENIS-impute gives priority to the ease of setting up, configuring and running an imputation. It has minimal dependencies and wraps the pipeline in a simple command line interface, without sacrificing flexibility to adapt or limiting the options of underlying imputation tools. It does not require knowledge of a workflow system or programming, and is targeted at researchers who just want to apply best practices in imputation via simple commands. It is built on the MOLGENIS compute workflow framework to enable customization with additional computational steps or it can be included in other bioinformatics pipelines. It is available as open source from: https://github.com/molgenis/molgenis-imputation.
Bidlingmaier, C; Kurnik, K; Hölscher, G; Kappler, M
2007-09-01
The introduction of new needleless devices as demanded by the US Department of Labor Occupational Safety and Health Administration (OSHA) has caused problems with the reconstitution of antihaemophilic factor in emergency situations. Our aim therefore was to evaluate the feasibility of a needleless device for reconstitution of antihaemophilic factor for non-haemophilia experts and to define evidence of the need for coaching these physicians via providing two additional photographs illustrating the two key points of the factor reconstitution process. Twenty-eight physicians of a tertiary care university children's hospital were randomized into two groups, either with no further explanation of the reconstitution device or with two additional photographs, showing the two key steps of the procedure. Reconstitution of dummy-factor concentrate was video-taped and evaluated by a blinded helper. Main outcome measure was the successful reconstitution of dummy-factor concentrate and procedure failure respectively. Of the group without explanation of the reconstitution device, only two of 14 physicians were able to reconstitute the dummy-factor concentrate. Of the group receiving two photographs, nine of 14 completed the task successfully (P = 0.0068). The needleless device is not self explaining to non-haemophilia physicians involved in emergency services. Coaching via short to the point instructions as provided by simple visual educational material therefore is crucial to enable these physicians to resolve the expensive emergency drug quickly and correctly. Companies concerned with the production of any devices to dissolve drugs, especially for treatment of rare diseases as haemophilia, therefore should take measures to simplify therapy.
NASA Astrophysics Data System (ADS)
Sumi, Tomonari; Okumoto, Atsushi; Goto, Hitoshi; Sekino, Hideo
2017-10-01
A two-step subdiffusion behavior of lateral movement of transmembrane proteins in plasma membranes has been observed by using single-molecule experiments. A nested double-compartment model where large compartments are divided into several smaller ones has been proposed in order to explain this observation. These compartments are considered to be delimited by membrane-skeleton "fences" and membrane-protein "pickets" bound to the fences. We perform numerical simulations of a master equation using a simple two-dimensional lattice model to investigate the heterogeneous diffusion dynamics behavior of transmembrane proteins within plasma membranes. We show that the experimentally observed two-step subdiffusion process can be described using fence and picket models combined with decreased local diffusivity of transmembrane proteins in the vicinity of the pickets. This allows us to explain the two-step subdiffusion behavior without explicitly introducing nested double compartments.
NASA Technical Reports Server (NTRS)
Schwenke, David W.; Langhoff, Stephen R. (Technical Monitor)
1995-01-01
A description is given of an algorithm for computing ro-vibrational energy levels for tetratomic molecules. The expressions required for evaluating transition intensities are also given. The variational principle is used to determine the energy levels and the kinetic energy operator is simple and evaluated exactly. The computational procedure is split up into the determination of one dimensional radial basis functions, the computation of a contracted rotational-bending basis, followed by a final variational step coupling all degrees of freedom. An angular basis is proposed whereby the rotational-bending contraction takes place in three steps. Angular matrix elements of the potential are evaluated by expansion in terms of a suitable basis and the angular integrals are given in a factorized form which simplifies their evaluation. The basis functions in the final variational step have the full permutation symmetries of the identical particles. Sample results are given for HCCH and BH3.
In situ hybridisation of EBV DNA-DNA hybrids using wet heat in polypropylene containers.
Labrecque, L G
1992-01-01
AIMS: To explore procedures designed to optimise DNA-DNA in situ hybridisation, using cells infected with Epstein-Barr virus (EBV) and tissues and subfragments of the EBV DNA as probes. METHODS: The denaturation step occurred in a polypropylene container, using wet heat generated by a hot water container, the pressure cooker, or the microwave oven, without coverslips, reaching a temperature of 121 degrees C or more in these two last systems. Two different visualisation systems were used. RESULTS: Fixed cells and tumours harbouring a high and medium to low copy number (a few hundreds to 33 copies per cell), were clearly labelled, using a simple reiterated subfragment (BamW) of the EBV DNA, and fresh frozen cells, harbouring a very low copy number (one to two on average) labelled using BamW as well as BamH (single non-reiterated 6 kilobase subfragment). CONCLUSION: This is a valuable alternative technique for DNA-DNA ISH that can be used in fresh frozen samples as well as fixed samples. Images PMID:1336018
NASA Astrophysics Data System (ADS)
Li, Tao; Zheng, Xiaogu; Dai, Yongjiu; Yang, Chi; Chen, Zhuoqi; Zhang, Shupeng; Wu, Guocan; Wang, Zhonglei; Huang, Chengcheng; Shen, Yan; Liao, Rongwei
2014-09-01
As part of a joint effort to construct an atmospheric forcing dataset for mainland China with high spatiotemporal resolution, a new approach is proposed to construct gridded near-surface temperature, relative humidity, wind speed and surface pressure with a resolution of 1 km×1 km. The approach comprises two steps: (1) fit a partial thin-plate smoothing spline with orography and reanalysis data as explanatory variables to ground-based observations for estimating a trend surface; (2) apply a simple kriging procedure to the residual for trend surface correction. The proposed approach is applied to observations collected at approximately 700 stations over mainland China. The generated forcing fields are compared with the corresponding components of the National Centers for Environmental Prediction (NCEP) Climate Forecast System Reanalysis dataset and the Princeton meteorological forcing dataset. The comparison shows that, both within the station network and within the resolutions of the two gridded datasets, the interpolation errors of the proposed approach are markedly smaller than the two gridded datasets.
Day, Charles A.; Kraft, Lewis J.; Kang, Minchul; Kenworthy, Anne K.
2012-01-01
Fluorescence recovery after photobleaching (FRAP) is a powerful, versatile and widely accessible tool to monitor molecular dynamics in living cells that can be performed using modern confocal microscopes. Although the basic principles of FRAP are simple, quantitative FRAP analysis requires careful experimental design, data collection and analysis. In this review we discuss the theoretical basis for confocal FRAP, followed by step-by-step protocols for FRAP data acquisition using a laser scanning confocal microscope for (1) measuring the diffusion of a membrane protein, (2) measuring the diffusion of a soluble protein, and (3) analysis of intracellular trafficking. Finally, data analysis procedures are discussed and an equation for determining the diffusion coefficient of a molecular species undergoing pure diffusion is presented. PMID:23042527
16 CFR § 1610.6 - Test procedure.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Test procedure. § 1610.6 Section § 1610.6... FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.6 Test procedure. The test procedure is divided into two... according to paragraph (b)(1) of this section. (a) Step 1—Testing in the original state. (1) Tests shall be...
Zhao, Wenle; Pauls, Keith
2015-01-01
Background Centralized outcome adjudication has been used widely in multi-center clinical trials in order to prevent potential biases and to reduce variations in important safety and efficacy outcome assessments. Adjudication procedures could vary significantly among different studies. In practice, the coordination of outcome adjudication procedures in many multicenter clinical trials remains as a manual process with low efficiency and high risk of delay. Motivated by the demands from two large clinical trial networks, a generic outcome adjudication module has been developed by the network’s data management center within a homegrown clinical trial management system. In this paper, the system design strategy and database structure are presented. Methods A generic database model was created to transfer different adjudication procedures into a unified set of sequential adjudication steps. Each adjudication step was defined by one activate condition, one lock condition, one to five categorical data items to capture adjudication results, and one free text field for general comments. Based on this model, a generic outcome adjudication user interface and a generic data processing program were developed within a homegrown clinical trial management system to provide automated coordination of outcome adjudication. Results By the end of 2014, this generic outcome adjudication module had been implemented in 10 multicenter trials. A total of 29 adjudication procedures were defined with the number of adjudication steps varying from 1 to 7. The implementation of a new adjudication procedure in this generic module took an experienced programmer one or two days. A total of 7,336 outcome events had been adjudicated and 16,235 adjudication step activities had been recorded. In a multicenter trial, 1144 safety outcome event submissions went through a three-step adjudication procedure and reported a median of 3.95 days from safety event case report form submission to adjudication completion. In another trial, 277 clinical outcome events were adjudicated by a six-step procedure and took a median of 23.84 days from outcome event case report form submission to adjudication procedure completion. Conclusions A generic outcome adjudication module integrated in the clinical trial management system made the automated coordination of efficacy and safety outcome adjudication a reality. PMID:26464429
Xiong, Ai-Sheng; Yao, Quan-Hong; Peng, Ri-He; Li, Xian; Fan, Hui-Qin; Cheng, Zong-Ming; Li, Yi
2004-07-07
Chemical synthesis of DNA sequences provides a powerful tool for modifying genes and for studying gene function, structure and expression. Here, we report a simple, high-fidelity and cost-effective PCR-based two-step DNA synthesis (PTDS) method for synthesis of long segments of DNA. The method involves two steps. (i) Synthesis of individual fragments of the DNA of interest: ten to twelve 60mer oligonucleotides with 20 bp overlap are mixed and a PCR reaction is carried out with high-fidelity DNA polymerase Pfu to produce DNA fragments that are approximately 500 bp in length. (ii) Synthesis of the entire sequence of the DNA of interest: five to ten PCR products from the first step are combined and used as the template for a second PCR reaction using high-fidelity DNA polymerase pyrobest, with the two outermost oligonucleotides as primers. Compared with the previously published methods, the PTDS method is rapid (5-7 days) and suitable for synthesizing long segments of DNA (5-6 kb) with high G + C contents, repetitive sequences or complex secondary structures. Thus, the PTDS method provides an alternative tool for synthesizing and assembling long genes with complex structures. Using the newly developed PTDS method, we have successfully obtained several genes of interest with sizes ranging from 1.0 to 5.4 kb.
Gerstner, Arpad; DeFord, James H; Papaconstantinou, John
2003-07-25
Ames dwarfism is caused by a homozygous single nucleotide mutation in the pituitary specific prop-1 gene, resulting in combined pituitary hormone deficiency, reduced growth and extended lifespan. Thus, these mice serve as an important model system for endocrinological, aging and longevity studies. Because the phenotype of wild type and heterozygous mice is undistinguishable, it is imperative for successful breeding to accurately genotype these animals. Here we report a novel, yet simple, approach for prop-1 genotyping using PCR-based allele-specific amplification (PCR-ASA). We also compare this method to other potential genotyping techniques, i.e. PCR-based restriction fragment length polymorphism analysis (PCR-RFLP) and fluorescence automated DNA sequencing. We demonstrate that the single-step PCR-ASA has several advantages over the classical PCR-RFLP because the procedure is simple, less expensive and rapid. To further increase the specificity and sensitivity of the PCR-ASA, we introduced a single-base mismatch at the 3' penultimate position of the mutant primer. Our results also reveal that the fluorescence automated DNA sequencing has limitations for detecting a single nucleotide polymorphism in the prop-1 gene, particularly in heterozygotes.
Wang, Shau-Chun; Lin, Chiao-Juan; Chiang, Shu-Min; Yu, Sung-Nien
2008-03-15
This paper reports a simple chemometric technique to alter the noise spectrum of a liquid chromatography-mass spectrometry (LC-MS) chromatogram between two consecutive second-derivative filter procedures to improve the peak signal-to-noise (S/N) ratio enhancement. This technique is to multiply one second-derivative filtered LC-MS chromatogram with another artificial chromatogram added with thermal noises prior to the other second-derivative filter. Because the second-derivative filter cannot eliminate frequency components within its own filter bandwidth, more efficient peak S/N ratio improvement cannot be accomplished using consecutive second-derivative filter procedures to process LC-MS chromatograms. In contrast, when the second-derivative filtered LC-MS chromatogram is conditioned with the multiplication alteration prior to the other second-derivative filter, much better ratio improvement is achieved. The noise frequency spectrum of the second-derivative filtered chromatogram, which originally contains frequency components within the filter bandwidth, is altered to span a broader range with multiplication operation. When the frequency range of this modified noise spectrum shifts toward the other regimes, the other second-derivative filter, working as a band-pass filter, is able to provide better filtering efficiency to obtain higher peak S/N ratios. Real LC-MS chromatograms, of which 5-fold peak S/N ratio improvement achieved with two consecutive second-derivative filters remains the same S/N ratio improvement using a one-step second-derivative filter, are improved to accomplish much better ratio enhancement, approximately 25-fold or higher when the noise frequency spectrum is modified between two matched filters. The linear standard curve using the filtered LC-MS signals is validated. The filtered LC-MS signals are also more reproducible. The more accurate determinations of very low-concentration samples (S/N ratio about 5-7) are obtained via standard addition procedures using the filtered signals rather than the determinations using the original signals.
32 CFR 644.409 - Procedures for Interchange of National Forest Lands.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 4 2010-07-01 2010-07-01 true Procedures for Interchange of National Forest... Interests § 644.409 Procedures for Interchange of National Forest Lands. (a) General. The interchange of national forest lands is accomplished in three steps: first, agreement must be reached between the two...
An Easy Synthesis of Two Cage Hydrocarbons.
ERIC Educational Resources Information Center
Dong, Dao Cong
1982-01-01
Describes a simple, three-step synthesis of two cage molecules, birdcage hydrocarbon (VIII) and its homologue, the homobirdcage hydrocarbon IX. Indicates that all products are easily purified and formed in high yields in this activity suitable for advanced undergraduate laboratory courses. (Author/JN)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin-Qiu Chen; Hong-Tao Zhang; Mei-Hao Hu
1995-10-01
The construction of a gene encoding Lys-human proinsulin, its direct expression in E.coli, and the simple purification procedure are described here. The temperature inducible promotor was employed for induction in a very short time. The expression level could reach 20-30%. After a simple downstream processing and only one step of Sephadex G50 purification, 150 mg recombinant Lys-human proinsulin with a purity of up to 90% could be obtained easily from 1 L of high density fermentation medium. The obtained product is in the form of Met-Lys-human proinsulin because of the failure of the bacterial host to remove the initiator methioninemore » residue. The Lys-human proinsulin could be changed into human insulin by tryspin and carboxypeptidase B treatment in later steps. After separation with DEAE Sephadex A25, human insulin with expected amino acid composition and full native biological activity could be obtained with a yield of 50 mg/L fermentation medium. 20 refs., 5 figs., 4 tabs.« less
Hughes, I
1998-09-24
The direct analysis of selected components from combinatorial libraries by sensitive methods such as mass spectrometry is potentially more efficient than deconvolution and tagging strategies since additional steps of resynthesis or introduction of molecular tags are avoided. A substituent selection procedure is described that eliminates the mass degeneracy commonly observed in libraries prepared by "split-and-mix" methods, without recourse to high-resolution mass measurements. A set of simple rules guides the choice of substituents such that all components of the library have unique nominal masses. Additional rules extend the scope by ensuring that characteristic isotopic mass patterns distinguish isobaric components. The method is applicable to libraries having from two to four varying substituent groups and can encode from a few hundred to several thousand components. No restrictions are imposed on the manner in which the "self-coded" library is synthesized or screened.
Lotfy, Hayam M; Amer, Sawsan M; Zaazaa, Hala E; Mostafa, Noha S
2015-01-01
Two novel simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed and validated for simultaneous determination of Esomeprazole magnesium trihydrate (ESO) and Naproxen (NAP) namely; absorbance subtraction and ratio difference. The results were compared to that of the conventional spectrophotometric methods namely; dual wavelength and isoabsorptive point coupled with first derivative of ratio spectra and derivative ratio. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for determination of ESO and NAP in their laboratory prepared mixtures and pharmaceutical preparation. No preliminary separation steps are required for the proposed spectrophotometeric procedures. The statistical comparison showed that there is no significant difference between the proposed methods and the reported method with respect to both accuracy and precision. Copyright © 2015 Elsevier B.V. All rights reserved.
Pérez-Faginas, Paula; Aranda, M. Teresa; García-López, M. Teresa; Infantes, Lourdes; Fernández-Carvajal, Asia; González-Ros, José Manuel; Ferrer-Montiel, Antonio; González-Muñiz, Rosario
2013-01-01
1,2-Diamine derivatives are valuable building blocks to heterocyclic compounds and important precursors of biologically relevant compounds. In this respect, amino acid-derived β–keto esters are a suitable starting point for the synthesis of β,γ–diamino ester derivatives through a two-step reductive amination procedure with either simple amines or α–amino esters. AcOH and NaBH3CN are the additive and reducing agents of choice. The stereoselectivity of the reaction is still an issue, due to the slow imine-enamine equilibria through which the reaction occurs, affording mixtures of diastereoisomers that can be chromatographically separated. Transformation of the β,γ–diamino esters into pyrrolidinone derivatives allows the configuration assignment of the linear compounds, and constitutes an example of their potential application in the generation of molecular diversity. PMID:23308167
Sato, Y; Sugie, R; Tsuchiya, B; Kameya, T; Natori, M; Mukai, K
2001-12-01
To obtain an adequate quality and quantity of DNA from formalin-fixed and paraffin-embedded tissue, six different DNA extraction methods were compared. Four methods used deparaffinization by xylene followed by proteinase K digestion and phenol-chloroform extraction. The temperature of the different steps was changed to obtain higher yields and improved quality of extracted DNA. The remaining two methods used microwave heating for deparaffinization. The best DNA extraction method consisted of deparaffinization by microwave irradiation, protein digestion with proteinase K at 48 degrees C overnight, and no further purification steps. By this method, the highest DNA yield was obtained and the amplification of a 989-base pair beta-globin gene fragment was achieved. Furthermore, DNA extracted by means of this procedure from five gastric carcinomas was successfully used for single strand conformation polymorphism and direct sequencing assays of the beta-catenin gene. Because the microwave-based DNA extraction method presented here is simple, has a lower contamination risk, and results in a higher yield of DNA compared with the ordinary organic chemical reagent-based extraction method, it is considered applicable to various clinical and basic fields.
A METHOD FOR DETERMINING THE COMPATIBILITY OF HAZARDOUS WASTES
This report describes a method for determining the compatibility of the binary combinations of hazardous wastes. The method consists of two main parts, namely: (1) the step-by-step compatibility analysis procedures, and (2) the hazardous wastes compatibility chart. The key elemen...
Liu, Zhao; Zhu, Yunhong; Wu, Chenxue
2016-01-01
Spatial-temporal k-anonymity has become a mainstream approach among techniques for protection of users’ privacy in location-based services (LBS) applications, and has been applied to several variants such as LBS snapshot queries and continuous queries. Analyzing large-scale spatial-temporal anonymity sets may benefit several LBS applications. In this paper, we propose two location prediction methods based on transition probability matrices constructing from sequential rules for spatial-temporal k-anonymity dataset. First, we define single-step sequential rules mined from sequential spatial-temporal k-anonymity datasets generated from continuous LBS queries for multiple users. We then construct transition probability matrices from mined single-step sequential rules, and normalize the transition probabilities in the transition matrices. Next, we regard a mobility model for an LBS requester as a stationary stochastic process and compute the n-step transition probability matrices by raising the normalized transition probability matrices to the power n. Furthermore, we propose two location prediction methods: rough prediction and accurate prediction. The former achieves the probabilities of arriving at target locations along simple paths those include only current locations, target locations and transition steps. By iteratively combining the probabilities for simple paths with n steps and the probabilities for detailed paths with n-1 steps, the latter method calculates transition probabilities for detailed paths with n steps from current locations to target locations. Finally, we conduct extensive experiments, and correctness and flexibility of our proposed algorithm have been verified. PMID:27508502
2014-01-01
Background Thresholds for statistical significance are insufficiently demonstrated by 95% confidence intervals or P-values when assessing results from randomised clinical trials. First, a P-value only shows the probability of getting a result assuming that the null hypothesis is true and does not reflect the probability of getting a result assuming an alternative hypothesis to the null hypothesis is true. Second, a confidence interval or a P-value showing significance may be caused by multiplicity. Third, statistical significance does not necessarily result in clinical significance. Therefore, assessment of intervention effects in randomised clinical trials deserves more rigour in order to become more valid. Methods Several methodologies for assessing the statistical and clinical significance of intervention effects in randomised clinical trials were considered. Balancing simplicity and comprehensiveness, a simple five-step procedure was developed. Results For a more valid assessment of results from a randomised clinical trial we propose the following five-steps: (1) report the confidence intervals and the exact P-values; (2) report Bayes factor for the primary outcome, being the ratio of the probability that a given trial result is compatible with a ‘null’ effect (corresponding to the P-value) divided by the probability that the trial result is compatible with the intervention effect hypothesised in the sample size calculation; (3) adjust the confidence intervals and the statistical significance threshold if the trial is stopped early or if interim analyses have been conducted; (4) adjust the confidence intervals and the P-values for multiplicity due to number of outcome comparisons; and (5) assess clinical significance of the trial results. Conclusions If the proposed five-step procedure is followed, this may increase the validity of assessments of intervention effects in randomised clinical trials. PMID:24588900
Effect of Critical Displacement Parameter on Slip Regime at Subduction Fault
NASA Astrophysics Data System (ADS)
Muldashev, Iskander; Sobolev, Stephan
2016-04-01
It is widely accepted that for the simple fault models value of critical displacement parameter (Dc) in Ruina-Dietrich's rate-and-state friction law is responsible for the transition from stick-slip regime at low Dc to non-seismic creep regime at large Dc. However, neither the value of "transition" Dc parameter nor the character of the transition is known for the realistic subduction zone setting. Here we investigate effect of Dc on regime of slip at subduction faults for two setups, generic model similar to simple shear elastic slider under quasistatic loading and full subduction model with appropriate geometry, stress and temperature distribution similar to the setting at the site of the Great Chile Earthquake of 1960. In our modeling we use finite element numerical technique that employs non-linear elasto-visco-plastic rheology in the entire model domain with rate-and-state plasticity within the fault zone. The model generates spontaneous earthquake sequence. Adaptive time-step integration procedure varies time step from 40 seconds at instability (earthquake), and gradually increases it to 5 years during postseismic relaxation. The technique allows observing the effect of Dc on period, magnitude of earthquakes through the cycles. We demonstrate that our modeling results for the generic model are consistent with the previous theoretical and numeric modeling results. For the full subduction model we obtain transition from non-seismic creep to stick-slip regime at Dc about 20 cm. We will demonstrate and discuss the features of the transition regimes in both generic and realistic subduction models.
Direct evaluation of fault trees using object-oriented programming techniques
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Koen, B. V.
1989-01-01
Object-oriented programming techniques are used in an algorithm for the direct evaluation of fault trees. The algorithm combines a simple bottom-up procedure for trees without repeated events with a top-down recursive procedure for trees with repeated events. The object-oriented approach results in a dynamic modularization of the tree at each step in the reduction process. The algorithm reduces the number of recursive calls required to solve trees with repeated events and calculates intermediate results as well as the solution of the top event. The intermediate results can be reused if part of the tree is modified. An example is presented in which the results of the algorithm implemented with conventional techniques are compared to those of the object-oriented approach.
A novel method for fabrication of continuous-relief optical elements
NASA Astrophysics Data System (ADS)
Guo, Xiaowei; Du, Jinglei; Chen, Mingyong; Ma, Yanqin; Zhu, Jianhua; Peng, Qinjun; Guo, Yongkang; Du, Chunlei
2005-08-01
A novel method for the fabrication of continuous micro-optical components is presented in this paper. It employs a computer controlled spatial-light-modulator (SLM) as a switchable projection mask and silver-halide sensitized gelatin (SHSG) as recording material. By etching SHSG with enzyme solution, the micro-optical components with relief modulation can be generated through special processing procedures. The principles of digital SLM-based lithography and enzyme etching SHSG are discussed in detail, and microlens arrays, micro axicon-lens arrays and gratings with good profile were achieved. This method is simple, cheap and the aberration in processing procedures can be in-situ corrected in the step of designing mask, so it is a practical method to fabricate continuous profile for low-volume production.
3D-fabrication of tunable and high-density arrays of crystalline silicon nanostructures
NASA Astrophysics Data System (ADS)
Wilbers, J. G. E.; Berenschot, J. W.; Tiggelaar, R. M.; Dogan, T.; Sugimura, K.; van der Wiel, W. G.; Gardeniers, J. G. E.; Tas, N. R.
2018-04-01
In this report, a procedure for the 3D-nanofabrication of ordered, high-density arrays of crystalline silicon nanostructures is described. Two nanolithography methods were utilized for the fabrication of the nanostructure array, viz. displacement Talbot lithography (DTL) and edge lithography (EL). DTL is employed to perform two (orthogonal) resist-patterning steps to pattern a thin Si3N4 layer. The resulting patterned double layer serves as an etch mask for all further etching steps for the fabrication of ordered arrays of silicon nanostructures. The arrays are made by means of anisotropic wet etching of silicon in combination with an isotropic retraction etch step of the etch mask, i.e. EL. The procedure enables fabrication of nanostructures with dimensions below 15 nm and a potential density of 1010 crystals cm-2.
NASA Spinoff Article: Automated Procedures To Improve Safety on Oil Rigs
NASA Technical Reports Server (NTRS)
Garud, Sumedha
2013-01-01
On May 11th, 2013, two astronauts emerged from the interior of the International Space Station (ISS) and worked their way toward the far end of spacecraft. Over the next 51/2 hours, the two replaced an ammonia pump that had developed a significant leak a few days before. On the ISS, ammonia serves the vital role of cooling components-in this case, one of the station's eight solar arrays. Throughout the extravehicular activity (EVA), the astronauts stayed in constant contact with mission control: every movement, every action strictly followed a carefully planned set of procedures to maximize crew safety and the chances of success. Though the leak had come as a surprise, NASA was prepared to handle it swiftly thanks in part to the thousands of procedures that have been written to cover every aspect of the ISS's operations. The ISS is not unique in this regard: Every NASA mission requires well-written procedures-or detailed lists of step-by-step instructions-that cover how to operate equipment in any scenario, from normal operations to the challenges created by malfunctioning hardware or software. Astronauts and mission control train and drill extensively in procedures to ensure they know what the proper procedures are and when they should be used. These procedures used to be exclusively written on paper, but over the past decade, NASA has transitioned to digital formats. Electronic-based documentation simplifies storage and use, allowing astronauts and flight controllers to find instructions more quickly and display them through a variety of media. Electronic procedures are also a crucial step toward automation: once instructions are digital, procedure display software can be designed to assist in authoring, reviewing, and even executing them.
Budzyńska, Agnieszka; Nowakowska-Duława, Ewa; Marek, Tomasz; Hartleb, Marek
2016-10-01
Most patients with malignant biliary obstruction are suited only for palliation by endoscopic drainage with plastic stents (PS) or self-expandable metal stents (SEMS). To compare the clinical outcome and costs of biliary stenting with SEMS and PS in patients with malignant biliary strictures. A total of 114 patients with malignant jaundice who underwent 376 endoscopic retrograde biliary drainage (ERBD) were studied. ERBD with the placement of PS was performed in 80 patients, with one-step SEMS in 20 patients and two-step SEMS in 14 patients. Significantly fewer ERBD interventions were performed in patients with one-step SEMS than PS or the two-step SEMS technique (2.0±1.12 vs. 3.1±1.7 or 5.7±2.1, respectively, P<0.0001). The median hospitalization duration per procedure was similar for the three groups of patients. The patients' survival time was the longest in the two-step SEMS group in comparison with the one-step SEMS and PS groups (596±270 vs. 276±141 or 208±219 days, P<0.001). Overall median time to recurrent biliary obstruction was 89.3±159 days for PS and 120.6±101 days for SEMS (P=0.01). The total cost of hospitalization with ERBD was higher for two-step SEMS than for one-step SEMS or PS (1448±312, 1152±135 and 977±156&OV0556;, P<0.0001). However, the estimated annual cost of medical care for one-step SEMS was higher than that for the two-step SEMS or PS groups (4618, 4079, and 3995&OV0556;, respectively). Biliary decompression by SEMS is associated with longer patency and reduced number of auxiliary procedures; however, repeated PS insertions still remain the most cost-effective strategy.
Nojavan, Saeed; Moharami, Arezoo; Fakhari, Ali Reza
2012-08-01
In this work, two-step hollow fiber-based liquid-phase microextraction procedure was evaluated for extraction of the zwitterionic cetirizine (CTZ) and basic hydroxyzine (HZ) in human plasma. In the first step of extraction, the pH of sample was adjusted at 5.0 in order to promote liquid-phase microextraction of the zwitterionic CTZ. In the second step, the pH of sample was increased up to 11.0 for extraction of basic HZ. In this procedure, the extraction times for the first and the second steps were 30 and 20 min, respectively. Owing to the high ratio between the volumes of donor phase and acceptor phase, CTZ and HZ were enriched by factors of 280 and 355, respectively. The linearity of the analytical method was investigated for both compounds in the range of 10-500 ng mL(-1) (R(2) > 0.999). Limit of quantification (S/N = 10) for CTZ and HZ was 10 ng mL(-1) , while the limit of detection was 3 ng mL(-1) for both compounds at a signal to noise ratio of 3:1. Intraday and interday relative standard deviations (RSDs, n = 6) were in the range of 6.5-16.2%. This procedure enabled CTZ and HZ to be analyzed simultaneously by capillary electrophoresis. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wan, Hui; Zhang, Kai; Rasch, Philip J.; ...
2017-02-03
A test procedure is proposed for identifying numerically significant solution changes in evolution equations used in atmospheric models. The test issues a fail signal when any code modifications or computing environment changes lead to solution differences that exceed the known time step sensitivity of the reference model. Initial evidence is provided using the Community Atmosphere Model (CAM) version 5.3 that the proposed procedure can be used to distinguish rounding-level solution changes from impacts of compiler optimization or parameter perturbation, which are known to cause substantial differences in the simulated climate. The test is not exhaustive since it does not detect issues associatedmore » with diagnostic calculations that do not feedback to the model state variables. Nevertheless, it provides a practical and objective way to assess the significance of solution changes. The short simulation length implies low computational cost. The independence between ensemble members allows for parallel execution of all simulations, thus facilitating fast turnaround. The new method is simple to implement since it does not require any code modifications. We expect that the same methodology can be used for any geophysical model to which the concept of time step convergence is applicable.« less
Two Experiments for Estimating Free Convection and Radiation Heat Transfer Coefficients
ERIC Educational Resources Information Center
Economides, Michael J.; Maloney, J. O.
1978-01-01
This article describes two simple undergraduate heat transfer experiments which may reinforce a student's understanding of free convection and radiation. Apparatus, experimental procedure, typical results, and discussion are included. (Author/BB)
Classical and special relativity in four steps
NASA Astrophysics Data System (ADS)
Browne, K. M.
2018-03-01
The most fundamental and pedagogically useful path to the space-time transformations of both classical and special relativity is to postulate the principle of relativity, derive the generalised or Ignatowsky transformation which contains both, then apply two different second postulates that give either the Galilean or Lorentz transformation. What is new here is (a) a simple two-step derivation of the Ignatowsky transformation, (b) a second postulate of universal time which yields the Galilean transformation, and (c) a different second postulate of finite universal lightspeed to give the Lorentz transformation using a simple Ignatowsky transformation of a light wave. This method demonstrates that the fundamental difference between Galilean and Lorentz transformations is not that lightspeed is universal (which is true for both) but whether the model requires lightspeed to be infinite or finite (as once mentioned by Einstein).
da Costa, Wiviane Kássia Oliveira Correia; da Silva, Caroline Santos; Figueiredo, José Fernando Dagnone; Nóbrega, Joaquim Araujo; Paim, Ana Paula Silveira
2018-06-05
A fast and simple dilute-and-shoot procedure for determination of Al, As, Ba, Cd, Cu, Fe, Mg, Mn, Ni, Pb, Sc, Ti, V, Zn and Zr in deodorants by inductively coupled plasma optical emission spectrometry (ICP OES) was developed. Sample preparation was carried out by diluting 1 mL of deodorant sample in 1% (v v -1 ) HNO 3 . The accuracy of the analytical procedure was evaluated using addition and recovery experiments, and recoveries ranged from 80 to 119%. The limits of detection varied from 0.001 to 0.76 mg kg -1 . Nine deodorants samples of different brands were analyzed. The maximum concentrations found (mg kg -1 ) were: Fe (1.0), Mn (0.1), Ti (1.02), V (0.33), Zn (255.2) and Zr (0.5); for Al and Mg, determined concentrations varied from 0.01 to 7.0% and from 0.005 to 1.44 mg kg -1 , respectively, showing wide variation depending on the sample type. The developed procedure was adequate for determining these analytes in routine analysis presenting high sample throughput and demonstrated the feasibility of direct analysis measurements after simple dilution step. Copyright © 2018 Elsevier B.V. All rights reserved.
Does my step look big in this? A visual illusion leads to safer stepping behaviour.
Elliott, David B; Vale, Anna; Whitaker, David; Buckley, John G
2009-01-01
Tripping is a common factor in falls and a typical safety strategy to avoid tripping on steps or stairs is to increase foot clearance over the step edge. In the present study we asked whether the perceived height of a step could be increased using a visual illusion and whether this would lead to the adoption of a safer stepping strategy, in terms of greater foot clearance over the step edge. The study also addressed the controversial question of whether motor actions are dissociated from visual perception. 21 young, healthy subjects perceived the step to be higher in a configuration of the horizontal-vertical illusion compared to a reverse configuration (p = 0.01). During a simple stepping task, maximum toe elevation changed by an amount corresponding to the size of the visual illusion (p<0.001). Linear regression analyses showed highly significant associations between perceived step height and maximum toe elevation for all conditions. The perceived height of a step can be manipulated using a simple visual illusion, leading to the adoption of a safer stepping strategy in terms of greater foot clearance over a step edge. In addition, the strong link found between perception of a visual illusion and visuomotor action provides additional support to the view that the original, controversial proposal by Goodale and Milner (1992) of two separate and distinct visual streams for perception and visuomotor action should be re-evaluated.
NASA Astrophysics Data System (ADS)
Juneja, A.; Lathrop, D. P.; Sreenivasan, K. R.; Stolovitzky, G.
1994-06-01
A family of schemes is outlined for constructing stochastic fields that are close to turbulence. The fields generated from the more sophisticated versions of these schemes differ little in terms of one-point and two-point statistics from velocity fluctuations in high-Reynolds-number turbulence; we shall designate such fields as synthetic turbulence. All schemes, implemented here in one dimension, consist of the following three ingredients, but differ in various details. First, a simple multiplicative procedure is utilized for generating an intermittent signal which has the same properties as those of the turbulent energy dissipation rate ɛ. Second, the properties of the intermittent signal averaged over an interval of size r are related to those of longitudinal velocity increments Δu(r), evaluated over the same distance r, through a stochastic variable V introduced in the spirit of Kolmogorov's refined similarity hypothesis. The third and final step, which partially resembles a well-known procedure for constructing fractional Brownian motion, consists of suitably combining velocity increments to construct an artificial velocity signal. Various properties of the synthetic turbulence are obtained both analytically and numerically, and found to be in good agreement with measurements made in the atmospheric surface layer. A brief review of some previous models is provided.
Savio, Marianela; Ortiz, María S; Almeida, César A; Olsina, Roberto A; Martinez, Luis D; Gil, Raúl A
2014-09-15
Trace metals have negative effects on the oxidative stability of edible oils and they are important because of possibility for oils characterisation. A single-step procedure for trace elemental analysis of edible oils is presented. To this aim, a solubilisation with tetramethylammonium hydroxide (TMAH) was assayed prior to inductively coupled plasma mass spectrometry detection. Small amounts of TMAH were used, resulting in high elemental concentrations. This method was applied to edible oils commercially available in Argentine. Elements present in small amounts (Cu, Ge, Mn, Mo, Ni, Sb, Sr, Ti, and V) were determined in olive, corn, almond and sunflower oils. The limits of detection were between 0.004 μg g(-1) for Mn and Sr, and 0.32 μg g(-1) for Sb. Principal components analysis was used to correlate the content of trace metals with the type of oils. The two first principal components retained 91.6% of the variability of the system. This is a relatively simple and safe procedure, and could be an attractive alternative for quality control, traceability and routine analysis of edible oils. Copyright © 2014 Elsevier Ltd. All rights reserved.
Aguilar, I; Misztal, I; Legarra, A; Tsuruta, S
2011-12-01
Genomic evaluations can be calculated using a unified procedure that combines phenotypic, pedigree and genomic information. Implementation of such a procedure requires the inverse of the relationship matrix based on pedigree and genomic relationships. The objective of this study was to investigate efficient computing options to create relationship matrices based on genomic markers and pedigree information as well as their inverses. SNP maker information was simulated for a panel of 40 K SNPs, with the number of genotyped animals up to 30 000. Matrix multiplication in the computation of the genomic relationship was by a simple 'do' loop, by two optimized versions of the loop, and by a specific matrix multiplication subroutine. Inversion was by a generalized inverse algorithm and by a LAPACK subroutine. With the most efficient choices and parallel processing, creation of matrices for 30 000 animals would take a few hours. Matrices required to implement a unified approach can be computed efficiently. Optimizations can be either by modifications of existing code or by the use of efficient automatic optimizations provided by open source or third-party libraries. © 2011 Blackwell Verlag GmbH.
Raijmakers, R; de Witte, T; Koekman, E; Wessels, J; Haanen, C
1986-01-01
Isopycnic density floatation centrifugation has been proven to be a suitable technique to enrich bone marrow aspirates for clonogenic cells on a small scale. We have tested a Haemonetics semicontinuous blood cell separator in order to process large volumes of bone marrow with minimal bone marrow manipulation. The efficacy of isopycnic density floatation was tested in a one and a two-step procedure. Both procedures showed a recovery of about 20% of the nucleated cells and 1-2% of the erythrocytes. The enrichment of clonogenic cells in the one-step procedure appeared superior to the two-step enrichment, first separating buffy coat cells. The recovery of clonogenic cells was 70 and 50%, respectively. Repopulation capacity of the low-density cell fraction containing the clonogenic cells was excellent after autologous reinfusion (6 cases) and allogeneic bone marrow transplantation (3 cases). Fast enrichment of large volumes of bone marrow aspirates with low-density cells containing the clonogenic cells by isopycnic density floatation centrifugation can be done safely using a Haemonetics blood cell separator.
Lower-cost cellulosic ethanol production using cellobiose fermenting yeast Clavispora NRRL Y-50464
USDA-ARS?s Scientific Manuscript database
For ethanol production from cellulosic materials, there are generally two major steps needed including enzymatic hydrolysis to break down biomass sugars and microbial fermentation to convert available simple sugars into ethanol. It often requires two different kinds of microorganisms since ethanolog...
Aortic valve replacement using continuous suture technique in patients with aortic valve disease.
Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku
2013-08-01
The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.
How to Use Chromatography as a Science Teaching Aid.
ERIC Educational Resources Information Center
Ganis, Frank M.
Presented are five procedures which permit the effective teaching of chromatography with equipment which is readily available, economical, and simple in design. The first procedure involves a study of solute partition in two immiscible solvents and of countercurrent distribution. The second illustrates the use of unidimensional ascending paper…
Improving patient care by making small sustainable changes: a cardiac telemetry unit's experience.
Braaten, Jane S; Bellhouse, Dorothy E
2007-01-01
With the introduction of each new drug, technology, and regulation, the processes of care become more complicated, creating an elaborate set of procedures connecting various hospital units and departments. Using methods of Adaptive Design and the Toyota Production System, a nursing unit redesigned work systems to achieve sustainable improvements in productivity, staff and patient satisfaction, and quality outcomes. The first hurdle of redesign was identifying problems, to which staff had become so accustomed with various work arounds that they had trouble seeing the process bottlenecks. Once the staff identified problems, they assumed they could solve the problem because they assumed they knew the causes. Utilizing root cause analysis, asking, "why, why, why," was essential to unearthing the true cause of a problem. Similarly, identifying solutions that were simple and low cost was an essential step in problem solving. Adopting new procedures and sustaining the commitment to identify and signal problems was a last and critical step toward realizing improvement, requiring a manager to function as "teacher/coach" rather than "fixer/firefighter".
Trouplin, Virginie; Salvatori, Francesca; Cappello, Fanny; Obry, Veronique; Brelot, Anne; Heveker, Nikolaus; Alizon, Marc; Scarlatti, Gabriella; Clavel, François; Mammano, Fabrizio
2001-01-01
We developed a recombinant virus technique to determine the coreceptor usage of human immunodeficiency virus type 1 (HIV-1) from plasma samples, the source expected to represent the most actively replicating virus population in infected subjects. This method is not subject to selective bias associated with virus isolation in culture, a step required for conventional tropism determination procedures. The addition of a simple subcloning step allowed semiquantitative evaluation of virus populations with a different coreceptor (CCR5 or CXCR4) usage specificity present in each plasma sample. This procedure detected mixtures of CCR5- and CXCR4-exclusive virus populations as well as dualtropic viral variants, in variable proportions. Sequence analysis of dualtropic clones indicated that changes in the V3 loop are necessary for the use of CXCR4 as a coreceptor, but the overall context of the V1-V3 region is important to preserve the capacity to use CCR5. This convenient technique can greatly assist the study of virus evolution and compartmentalization in infected individuals. PMID:11119595
Chen, Cheng-Che; Yang, Cheng-Kuang; Hung, Siu-Wan; Wang, John; Ou, Yen-Chuan
2015-10-01
The use of a da Vinci robotic system may improve the outcome of urological surgery. This study reports 6 years of experience with vesicourethral anastomosis (VUA) following robot-assisted laparoscopic radical prostatectomy (RALP) performed in Taichung Veterans General Hospital, Taichung, Taiwan. A total of 350 patients who underwent RALP by a single surgeon were reviewed. We followed Dr Patel's RALP procedure with minor modifications. VUA was checked with 120 mL and 200 mL saline in sequence. The urinary bladder was then pressed with endoscopic instruments. If a VUA leak was detected, it was sutured immediately. An 18-French silicon Foley's catheter was inserted and removed 7-14 days after RALP. Preoperative characteristics and perioperative complications were assessed. Overall, 332 (94.85%) patients were without any leakage in the first step of the challenge, eight of whom had leakage in the second step. After repair, all were free from leakage. The other 18 patients had leakage in the first step of the challenge (5.14%). After repair, 12 patients were without leakage in the second step. However, one patient had urine leakage postoperatively. The other six patients had leakage in the second step. After repair, two patients were free from leakage, but the remaining four suffered from persistent minor urine leakage postoperatively. The urine leakage rate after RALP was 1.43% (5/350). The potential urine leakage after bladder challenge and endoscopic instruments pressing could be minimized to 0.29% (1/346). VUA leakage after RALP is rare. Intraoperative VUA challenge is simple and feasible compared to postoperative retrograde cystography. Copyright © 2014. Published by Elsevier B.V.
Shrivas, Kamlesh; Wu, Hui-Fen
2008-02-01
A novel, rapid and simple sample pretreatment technique termed ultrasonication followed by single-drop micro-extraction (U-SDME) has been developed and combined with GC/MS for the determination of organochlorine pesticides (OCPs) in fish. In the present work, the lengthy procedures generally used in the conventional methods like, Soxhlet extraction, supercritical fluid extraction, pressurized liquid extraction and microwave assisted solvent extraction for extraction of OCPs from fish tissues are minimized by the use of two simple extraction procedures. Firstly, OCPs from fish were extracted in organic solvent with ultrasonication and then subsequently preconcentrated by single-drop micro-extraction (SDME). Extraction parameters of ultrasonication and SDME were optimized in spiked sample solution in order to obtain efficient extraction of OCPs from fish tissues. The calibration curves for OCPs were found to be linear between 10-1000 ng/g with correlation of estimations in the range 0.990-0.994. The recoveries obtained in blank fish tissues were ranged from 82.1 to 95.3%. The LOD and RSD for determination of OCPs in fish were 0.5 ng/g and 9.4-10.0%, respectively. The proposed method was applied for the determination of bioconcentration factor in fish after exposure to different concentrations of OCPs in cultured water. The present method avoids the co-extraction of lipids, long extraction steps (>12 h) and large amount of organic solvent for the separation of OCPs. The main advantages of the present method are rapid, selective, sensitive and low cost for the determination of OCPs in fish.
NASA Technical Reports Server (NTRS)
Molnar, Melissa; Marek, C. John
2005-01-01
A simplified kinetic scheme for Jet-A, and methane fuels with water injection was developed to be used in numerical combustion codes, such as the National Combustor Code (NCC) or even simple FORTRAN codes. The two time step method is either an initial time averaged value (step one) or an instantaneous value (step two). The switch is based on the water concentration in moles/cc of 1x10(exp -20). The results presented here results in a correlation that gives the chemical kinetic time as two separate functions. This two time step method is used as opposed to a one step time averaged method previously developed to determine the chemical kinetic time with increased accuracy. The first time averaged step is used at the initial times for smaller water concentrations. This gives the average chemical kinetic time as a function of initial overall fuel air ratio, initial water to fuel mass ratio, temperature, and pressure. The second instantaneous step, to be used with higher water concentrations, gives the chemical kinetic time as a function of instantaneous fuel and water mole concentration, pressure and temperature (T4). The simple correlations would then be compared to the turbulent mixing times to determine the limiting rates of the reaction. The NASA Glenn GLSENS kinetics code calculates the reaction rates and rate constants for each species in a kinetic scheme for finite kinetic rates. These reaction rates are used to calculate the necessary chemical kinetic times. Chemical kinetic time equations for fuel, carbon monoxide and NOx are obtained for Jet-A fuel and methane with and without water injection to water mass loadings of 2/1 water to fuel. A similar correlation was also developed using data from NASA's Chemical Equilibrium Applications (CEA) code to determine the equilibrium concentrations of carbon monoxide and nitrogen oxide as functions of overall equivalence ratio, water to fuel mass ratio, pressure and temperature (T3). The temperature of the gas entering the turbine (T4) was also correlated as a function of the initial combustor temperature (T3), equivalence ratio, water to fuel mass ratio, and pressure.
ERIC Educational Resources Information Center
Gilbert, George L., Ed.
1988-01-01
Describes two demonstrations for college level chemistry courses including: "Electrochemical Cells Using Sodium Silicate" and "A Simple, Vivid Demonstration of Selective Precipitation." Lists materials, preparation, procedures, and precautions. (CW)
Migraines: Simple Steps to Head Off the Pain
Migraines: Simple steps to head off the pain Migraines cause pain as real as the pain of ... Healthy habits and simple nonmedical remedies sometimes stop migraines before they start. By Mayo Clinic Staff Medication ...
Platelet-rich plasma differs according to preparation method and human variability.
Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Cote, Mark P; Romeo, Anthony A; Bradley, James P; Arciero, Robert A; Beitzel, Knut
2012-02-15
Varying concentrations of blood components in platelet-rich plasma preparations may contribute to the variable results seen in recently published clinical studies. The purposes of this investigation were (1) to quantify the level of platelets, growth factors, red blood cells, and white blood cells in so-called one-step (clinically used commercial devices) and two-step separation systems and (2) to determine the influence of three separate blood draws on the resulting components of platelet-rich plasma. Three different platelet-rich plasma (PRP) separation methods (on blood samples from eight subjects with a mean age [and standard deviation] of 31.6 ± 10.9 years) were used: two single-spin processes (PRPLP and PRPHP) and a double-spin process (PRPDS) were evaluated for concentrations of platelets, red and white blood cells, and growth factors. Additionally, the effect of three repetitive blood draws on platelet-rich plasma components was evaluated. The content and concentrations of platelets, white blood cells, and growth factors for each method of separation differed significantly. All separation techniques resulted in a significant increase in platelet concentration compared with native blood. Platelet and white blood-cell concentrations of the PRPHP procedure were significantly higher than platelet and white blood-cell concentrations produced by the so-called single-step PRPLP and the so-called two-step PRPDS procedures, although significant differences between PRPLP and PRPDS were not observed. Comparing the results of the three blood draws with regard to the reliability of platelet number and cell counts, wide variations of intra-individual numbers were observed. Single-step procedures are capable of producing sufficient amounts of platelets for clinical usage. Within the evaluated procedures, platelet numbers and numbers of white blood cells differ significantly. The intra-individual results of platelet-rich plasma separations showed wide variations in platelet and cell numbers as well as levels of growth factors regardless of separation method.
Step 6: Does Not Routinely Employ Practices, Procedures Unsupported by Scientific Evidence
Goer, Henci; Sagady Leslie, Mayri; Romano, Amy
2007-01-01
Step 6 of the Ten Steps of Mother-Friendly Care addresses two issues: 1) the routine use of interventions (shaving, enemas, intravenous drips, withholding food and fluids, early rupture of membranes, and continuous electronic fetal monitoring; and 2) the optimal rates of induction, episiotomy, cesareans, and vaginal births after cesarean. Rationales for compliance and systematic reviews are presented. PMID:18523680
Modeling of polychromatic attenuation using computed tomography reconstructed images
NASA Technical Reports Server (NTRS)
Yan, C. H.; Whalen, R. T.; Beaupre, G. S.; Yen, S. Y.; Napel, S.
1999-01-01
This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.
Simple Correction of Alar Retraction by Conchal Cartilage Extension Grafts.
Jang, Yong Jun; Kim, Sung Min; Lew, Dae Hyun; Song, Seung Yong
2016-11-01
Alar retraction is a challenging condition in rhinoplasty marked by exaggerated nostril exposure and awkwardness. Although various methods for correcting alar retraction have been introduced, none is without drawbacks. Herein, we report a simple procedure that is both effective and safe for correcting alar retraction using only conchal cartilage grafting. Between August 2007 and August 2009, 18 patients underwent conchal cartilage extension grafting to correct alar retraction. Conchal cartilage extension grafts were fixed to the caudal margins of the lateral crura and covered with vestibular skin advancement flaps. Preoperative and postoperative photographs were reviewed and analyzed. Patient satisfaction was surveyed and categorized into 4 groups (very satisfied, satisfied, moderate, or unsatisfied). According to the survey, 8 patients were very satisfied, 9 were satisfied, and 1 considered the outcome moderate, resulting in satisfaction for most patients. The average distance from the alar rim to the long axis of the nostril was reduced by 1.4 mm (3.6 to 2.2 mm). There were no complications, except in 2 cases with palpable cartilage step-off that resolved without any aesthetic problems. Conchal cartilage alar extension graft is a simple, effective method of correcting alar retraction that can be combined with aesthetic rhinoplasty conveniently, utilizing conchal cartilage, which is the most similar cartilage to alar cartilage, and requiring a lesser volume of cartilage harvest compared to previously devised methods. However, the current procedure lacks efficacy for severe alar retraction and a longer follow-up period may be required to substantiate the enduring efficacy of the current procedure.
ERIC Educational Resources Information Center
Sinharay, Sandip; Dorans, Neil J.
2010-01-01
The Mantel-Haenszel (MH) procedure (Mantel and Haenszel) is a popular method for estimating and testing a common two-factor association parameter in a 2 x 2 x K table. Holland and Holland and Thayer described how to use the procedure to detect differential item functioning (DIF) for tests with dichotomously scored items. Wang, Bradlow, Wainer, and…
Band Structure Simulations of the Photoinduced Changes in the MgB₂:Cr Films.
Kityk, Iwan V; Fedorchuk, Anatolii O; Ozga, Katarzyna; AlZayed, Nasser S
2015-04-02
An approach for description of the photoinduced nonlinear optical effects in the superconducting MgB₂:Cr₂O₃ nanocrystalline film is proposed. It includes the molecular dynamics step-by-step optimization of the two separate crystalline phases. The principal role for the photoinduced nonlinear optical properties plays nanointerface between the two phases. The first modified layers possess a form of slightly modified perfect crystalline structure. The next layer is added to the perfect crystalline structure and the iteration procedure is repeated for the next layer. The total energy here is considered as a varied parameter. To avoid potential jumps on the borders we have carried out additional derivative procedure.
ERIC Educational Resources Information Center
Stowell, Stephen
1995-01-01
Presents a high school unit about the U.S. Industrial Revolution featuring the Boott Cotton Mills of Lowell, Massachusetts. Includes student objectives, step-by-step instructional procedures, and discussion questions. Provides two maps, five illustrations, one photograph, and three student readings. (ACM)
Coarse mesh and one-cell block inversion based diffusion synthetic acceleration
NASA Astrophysics Data System (ADS)
Kim, Kang-Seog
DSA (Diffusion Synthetic Acceleration) has been developed to accelerate the SN transport iteration. We have developed solution techniques for the diffusion equations of FLBLD (Fully Lumped Bilinear Discontinuous), SCB (Simple Comer Balance) and UCB (Upstream Corner Balance) modified 4-step DSA in x-y geometry. Our first multi-level method includes a block Gauss-Seidel iteration for the discontinuous diffusion equation, uses the continuous diffusion equation derived from the asymptotic analysis, and avoids void cell calculation. We implemented this multi-level procedure and performed model problem calculations. The results showed that the FLBLD, SCB and UCB modified 4-step DSA schemes with this multi-level technique are unconditionally stable and rapidly convergent. We suggested a simplified multi-level technique for FLBLD, SCB and UCB modified 4-step DSA. This new procedure does not include iterations on the diffusion calculation or the residual calculation. Fourier analysis results showed that this new procedure was as rapidly convergent as conventional modified 4-step DSA. We developed new DSA procedures coupled with 1-CI (Cell Block Inversion) transport which can be easily parallelized. We showed that 1-CI based DSA schemes preceded by SI (Source Iteration) are efficient and rapidly convergent for LD (Linear Discontinuous) and LLD (Lumped Linear Discontinuous) in slab geometry and for BLD (Bilinear Discontinuous) and FLBLD in x-y geometry. For 1-CI based DSA without SI in slab geometry, the results showed that this procedure is very efficient and effective for all cases. We also showed that 1-CI based DSA in x-y geometry was not effective for thin mesh spacings, but is effective and rapidly convergent for intermediate and thick mesh spacings. We demonstrated that the diffusion equation discretized on a coarse mesh could be employed to accelerate the transport equation. Our results showed that coarse mesh DSA is unconditionally stable and is as rapidly convergent as fine mesh DSA in slab geometry. For x-y geometry our coarse mesh DSA is very effective for thin and intermediate mesh spacings independent of the scattering ratio, but is not effective for purely scattering problems and high aspect ratio zoning. However, if the scattering ratio is less than about 0.95, this procedure is very effective for all mesh spacing.
Evidence integration in model-based tree search
Solway, Alec; Botvinick, Matthew M.
2015-01-01
Research on the dynamics of reward-based, goal-directed decision making has largely focused on simple choice, where participants decide among a set of unitary, mutually exclusive options. Recent work suggests that the deliberation process underlying simple choice can be understood in terms of evidence integration: Noisy evidence in favor of each option accrues over time, until the evidence in favor of one option is significantly greater than the rest. However, real-life decisions often involve not one, but several steps of action, requiring a consideration of cumulative rewards and a sensitivity to recursive decision structure. We present results from two experiments that leveraged techniques previously applied to simple choice to shed light on the deliberation process underlying multistep choice. We interpret the results from these experiments in terms of a new computational model, which extends the evidence accumulation perspective to multiple steps of action. PMID:26324932
Phase-field crystal modeling of heteroepitaxy and exotic modes of crystal nucleation
NASA Astrophysics Data System (ADS)
Podmaniczky, Frigyes; Tóth, Gyula I.; Tegze, György; Pusztai, Tamás; Gránásy, László
2017-01-01
We review recent advances made in modeling heteroepitaxy, two-step nucleation, and nucleation at the growth front within the framework of a simple dynamical density functional theory, the Phase-Field Crystal (PFC) model. The crystalline substrate is represented by spatially confined periodic potentials. We investigate the misfit dependence of the critical thickness in the StranskiKrastanov growth mode in isothermal studies. Apparently, the simulation results for stress release via the misfit dislocations fit better to the PeopleBean model than to the one by Matthews and Blakeslee. Next, we investigate structural aspects of two-step crystal nucleation at high undercoolings, where an amorphous precursor forms in the first stage. Finally, we present results for the formation of new grains at the solid-liquid interface at high supersaturations/supercoolings, a phenomenon termed Growth Front Nucleation (GFN). Results obtained with diffusive dynamics (applicable to colloids) and with a hydrodynamic extension of the PFC theory (HPFC, developed for simple liquids) will be compared. The HPFC simulations indicate two possible mechanisms for GFN.
Data Processing for Atmospheric Phase Interferometers
NASA Technical Reports Server (NTRS)
Acosta, Roberto J.; Nessel, James A.; Morabito, David D.
2009-01-01
This paper presents a detailed discussion of calibration procedures used to analyze data recorded from a two-element atmospheric phase interferometer (API) deployed at Goldstone, California. In addition, we describe the data products derived from those measurements that can be used for site intercomparison and atmospheric modeling. Simulated data is used to demonstrate the effectiveness of the proposed algorithm and as a means for validating our procedure. A study of the effect of block size filtering is presented to justify our process for isolating atmospheric fluctuation phenomena from other system-induced effects (e.g., satellite motion, thermal drift). A simulated 24 hr interferometer phase data time series is analyzed to illustrate the step-by-step calibration procedure and desired data products.
Two steps hydrothermal growth and characterisations of BaTiO3 films composed of nanowires
NASA Astrophysics Data System (ADS)
Zawawi, Che Zaheerah Najeehah Che Mohd; Salleh, Shahril; Oon Jew, Lee; Tufail Chaudhary, Kashif; Helmi, Mohamad; Safwan Aziz, Muhammad; Haider, Zuhaib; Ali, Jalil
2018-05-01
Barium titanate (BaTiO3) films composed of nanowires have gained considerable research interest due to their lead-free composition and strong energy conversion efficiency. BaTiO3 films can be developed with a simple two steps hydrothermal reactions, which are low cost effective. In this research, BaTiO3 films were fabricated on titanium foil through two steps hydrothermal method namely, the growth of TiO2 and followed by BaTiO3 films. The structural evolutions and the dielectric properties of the films were investigated as well. The structural evolutions of titanium dioxide (TiO2) and BaTiO3 nanowires were characterized using X-ray diffraction and scanning electron microscopy. First step of hydrothermal reaction, TiO2 nanowires were prepared in varied temperatures of 160 °C, 200 °C and 250 °C respectively. Second step of hydrothermal reaction was performed to produce a layer of BaTiO3 films.
DETERMINATION OF PESTICIDES AND PCB'S IN INDUSTRIAL AND MUNICIPAL WASTEWATERS
Steps in the procedure for the analysis of 25 chlorinated pesticides and polychlorinated biphenyls were studied. Two gas chromatographic columns and two detectors (electron capture and Hall electrolytic conductivity) were evaluated. Extractions were performed with two solvents (d...
Ulrich, G.A.; Krumholz, L.R.; Suflita, J.M.
1997-01-01
A simplified passive extraction procedure for quantifying reduced inorganic sulfur compounds from sediments and water is presented. This method may also be used for the estimation of sulfate reduction rates. Efficient extraction of FeS, FeS(inf2), and S(sup2-) was obtained with this procedure; however, the efficiency for S(sup0) depended on the form that was tested. Passive extraction can be used with samples containing up to 20 mg of reduced sulfur. We demonstrated the utility of this technique in a determination of both sulfate reduction rates and reduced inorganic sulfur pools in marine and freshwater sediments. A side-by-side comparison of the passive extraction method with the established single-step distillation technique yielded comparable results with a fraction of the effort.
Smartphone-aided measurements of the speed of sound in different gaseous mixtures
NASA Astrophysics Data System (ADS)
Parolin, Sara Orsola; Pezzi, Giovanni
2013-11-01
Here we describe classroom-based procedures aiming at the estimation of the speed of sound in different gas mixtures with the help of a plastic drain pipe and two iPhones or iPod touches. The procedures were conceived to be performed with simple and readily available tools.
Smartphone-Aided Measurements of the Speed of Sound in Different Gaseous Mixtures
ERIC Educational Resources Information Center
Parolin, Sara Orsola; Pezzi, Giovanni
2013-01-01
Here we describe classroom-based procedures aiming at the estimation of the speed of sound in different gas mixtures with the help of a plastic drain pipe and two iPhones or iPod touches. The procedures were conceived to be performed with simple and readily available tools.
Psychological Distance to Reward: Effects of S+ Duration and the Delay Reduction It Signals
ERIC Educational Resources Information Center
Alessandri, Jerome; Stolarz-Fantino, Stephanie; Fantino, Edmund
2011-01-01
A concurrent-chains procedure was used to examine choice between segmented (two-component chained schedules) and unsegmented schedules (simple schedules) in terminal links with equal inter-reinforcement intervals. Previous studies using this kind of experimental procedure showed preference for unsegmented schedules for both pigeons and humans. In…
Two-step iron(0)-mediated N-demethylation of N-methyl alkaloids.
Kok, Gaik B; Pye, Cory C; Singer, Robert D; Scammells, Peter J
2010-07-16
A mild and simple two-step Fe(0)-mediated N-demethylation of a number of tertiary N-methyl alkaloids is described. The tertiary N-methylamine is first oxidized to the corresponding N-oxide, which is isolated as the hydrochloride salt. Subsequent treatment of the N-oxide hydrochloride with iron powder readily provides the N-demethylated amine. Representative substrates include a number of opiate and tropane alkaloids. Key intermediates in the synthesis of semisynthetic 14-hydroxy pharmaceutical opiates such as oxycodone and oxymorphone are also readily N-demethylated using this method.
Rolider, A; Van Houten, R
1985-01-01
The effects of a movement suppression time-out, which involved punishing any movement or verbalization while a client is in the time-out area, were evaluated in four experiments. The first experiment examined the effects of a DRO procedure and movement suppression plus DRO in suppressing self-injurious behavior in a psychotic child in three different situations. In Experiment 2, the results of the previous experiment were replicated with two dangerous behaviors in a second psychotic child. In a third experiment, movement suppression plus DRO was compared with contingent restraint in reducing inappropriate poking behavior in two settings. The movement suppression procedure eliminated poking whereas contingent restraint had little effect. In the final experiment, movement suppression time-out alone was compared with exclusionary time-out alone and simple corner time-out alone. Self-stimulation occurred at high levels during the exclusionary and simple corner time-out procedures. Self-stimulation was either suppressed or reduced during movement suppression time-out. The movement suppression time-out procedure produced a larger reduction in the target behavior in all three children. The effectiveness of the movement suppression procedure was explained in terms of the suppression of self-stimulation while the time-out procedure was being applied.
2012-01-01
Background A single-step blending approach allows genomic prediction using information of genotyped and non-genotyped animals simultaneously. However, the combined relationship matrix in a single-step method may need to be adjusted because marker-based and pedigree-based relationship matrices may not be on the same scale. The same may apply when a GBLUP model includes both genomic breeding values and residual polygenic effects. The objective of this study was to compare single-step blending methods and GBLUP methods with and without adjustment of the genomic relationship matrix for genomic prediction of 16 traits in the Nordic Holstein population. Methods The data consisted of de-regressed proofs (DRP) for 5 214 genotyped and 9 374 non-genotyped bulls. The bulls were divided into a training and a validation population by birth date, October 1, 2001. Five approaches for genomic prediction were used: 1) a simple GBLUP method, 2) a GBLUP method with a polygenic effect, 3) an adjusted GBLUP method with a polygenic effect, 4) a single-step blending method, and 5) an adjusted single-step blending method. In the adjusted GBLUP and single-step methods, the genomic relationship matrix was adjusted for the difference of scale between the genomic and the pedigree relationship matrices. A set of weights on the pedigree relationship matrix (ranging from 0.05 to 0.40) was used to build the combined relationship matrix in the single-step blending method and the GBLUP method with a polygenetic effect. Results Averaged over the 16 traits, reliabilities of genomic breeding values predicted using the GBLUP method with a polygenic effect (relative weight of 0.20) were 0.3% higher than reliabilities from the simple GBLUP method (without a polygenic effect). The adjusted single-step blending and original single-step blending methods (relative weight of 0.20) had average reliabilities that were 2.1% and 1.8% higher than the simple GBLUP method, respectively. In addition, the GBLUP method with a polygenic effect led to less bias of genomic predictions than the simple GBLUP method, and both single-step blending methods yielded less bias of predictions than all GBLUP methods. Conclusions The single-step blending method is an appealing approach for practical genomic prediction in dairy cattle. Genomic prediction from the single-step blending method can be improved by adjusting the scale of the genomic relationship matrix. PMID:22455934
Global phenomena from local rules: Peer-to-peer networks and crystal steps
NASA Astrophysics Data System (ADS)
Finkbiner, Amy
Even simple, deterministic rules can generate interesting behavior in dynamical systems. This dissertation examines some real world systems for which fairly simple, locally defined rules yield useful or interesting properties in the system as a whole. In particular, we study routing in peer-to-peer networks and the motion of crystal steps. Peers can vary by three orders of magnitude in their capacities to process network traffic. This heterogeneity inspires our use of "proportionate load balancing," where each peer provides resources in proportion to its individual capacity. We provide an implementation that employs small, local adjustments to bring the entire network into a global balance. Analytically and through simulations, we demonstrate the effectiveness of proportionate load balancing on two routing methods for de Bruijn graphs, introducing a new "reversed" routing method which performs better than standard forward routing in some cases. The prevalence of peer-to-peer applications prompts companies to locate the hosts participating in these networks. We explore the use of supervised machine learning to identify peer-to-peer hosts, without using application-specific information. We introduce a model for "triples," which exploits information about nearly contemporaneous flows to give a statistical picture of a host's activities. We find that triples, together with measurements of inbound vs. outbound traffic, can capture most of the behavior of peer-to-peer hosts. An understanding of crystal surface evolution is important for the development of modern nanoscale electronic devices. The most commonly studied surface features are steps, which form at low temperatures when the crystal is cut close to a plane of symmetry. Step bunching, when steps arrange into widely separated clusters of tightly packed steps, is one important step phenomenon. We analyze a discrete model for crystal steps, in which the motion of each step depends on the two steps on either side of it. We find an time-dependence term for the motion that does not appear in continuum models, and we determine an explicit dependence on step number.
Phillips, Steven P.; Belitz, Kenneth
1991-01-01
The occurrence of selenium in agricultural drain water from the western San Joaquin Valley, California, has focused concern on the semiconfined ground-water flow system, which is underlain by the Corcoran Clay Member of the Tulare Formation. A two-step procedure is used to calibrate a preliminary model of the system for the purpose of determining the steady-state hydraulic properties. Horizontal and vertical hydraulic conductivities are modeled as functions of the percentage of coarse sediment, hydraulic conductivities of coarse-textured (Kcoarse) and fine-textured (Kfine) end members, and averaging methods used to calculate equivalent hydraulic conductivities. The vertical conductivity of the Corcoran (Kcorc) is an additional parameter to be evaluated. In the first step of the calibration procedure, the model is run by systematically varying the following variables: (1) Kcoarse/Kfine, (2) Kcoarse/Kcorc, and (3) choice of averaging methods in the horizontal and vertical directions. Root mean square error and bias values calculated from the model results are functions of these variables. These measures of error provide a means for evaluating model sensitivity and for selecting values of Kcoarse, Kfine, and Kcorc for use in the second step of the calibration procedure. In the second step, recharge rates are evaluated as functions of Kcoarse, Kcorc, and a combination of averaging methods. The associated Kfine values are selected so that the root mean square error is minimized on the basis of the results from the first step. The results of the two-step procedure indicate that the spatial distribution of hydraulic conductivity that best produces the measured hydraulic head distribution is created through the use of arithmetic averaging in the horizontal direction and either geometric or harmonic averaging in the vertical direction. The equivalent hydraulic conductivities resulting from either combination of averaging methods compare favorably to field- and laboratory-based values.
Estimating Slope and Level Change in N = 1 Designs
ERIC Educational Resources Information Center
Solanas, Antonio; Manolov, Rumen; Onghena, Patrick
2010-01-01
The current study proposes a new procedure for separately estimating slope change and level change between two adjacent phases in single-case designs. The procedure eliminates baseline trend from the whole data series before assessing treatment effectiveness. The steps necessary to obtain the estimates are presented in detail, explained, and…
Perception of School Safety of a Local School
ERIC Educational Resources Information Center
Massey-Jones, Darla
2013-01-01
This qualitative case study investigated the perception of school safety, what current policies and procedures were effective, and what policies and procedures should be implemented. Data were collected in two steps, by survey and focus group interview. Analysis determined codes that revealed several themes relevant to the perception of school…
2013-01-01
Carbon nanotube (CNT) membranes allow the mimicking of natural ion channels for applications in drug delivery and chemical separation. Double-walled carbon nanotube membranes were simply functionalized with dye in a single step instead of the previous two-step functionalization. Non-faradic electrochemical impedance spectra indicated that the functionalized gatekeeper by single-step modification can be actuated to mimic the protein channel under bias. This functional chemistry was proven by a highly efficient ion rectification, wherein the highest experimental rectification factor of ferricyanide was up to 14.4. One-step functionalization by electrooxidation of amine provides a simple and promising functionalization chemistry for the application of CNT membranes. PMID:23758999
One Step Quantum Key Distribution Based on EPR Entanglement.
Li, Jian; Li, Na; Li, Lei-Lei; Wang, Tao
2016-06-30
A novel quantum key distribution protocol is presented, based on entanglement and dense coding and allowing asymptotically secure key distribution. Considering the storage time limit of quantum bits, a grouping quantum key distribution protocol is proposed, which overcomes the vulnerability of first protocol and improves the maneuverability. Moreover, a security analysis is given and a simple type of eavesdropper's attack would introduce at least an error rate of 46.875%. Compared with the "Ping-pong" protocol involving two steps, the proposed protocol does not need to store the qubit and only involves one step.
14 CFR 302.37 - Waiver of procedural steps after hearing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Waiver of procedural steps after hearing... Applicability Oral Evidentiary Hearing Proceedings § 302.37 Waiver of procedural steps after hearing. The parties to any proceeding may agree to waive any one or more of the procedural steps provided in § 302.29...
A two-step initial mass function:. Consequences of clustered star formation for binary properties
NASA Astrophysics Data System (ADS)
Durisen, R. H.; Sterzik, M. F.; Pickett, B. K.
2001-06-01
If stars originate in transient bound clusters of moderate size, these clusters will decay due to dynamic interactions in which a hard binary forms and ejects most or all the other stars. When the cluster members are chosen at random from a reasonable initial mass function (IMF), the resulting binary characteristics do not match current observations. We find a significant improvement in the trends of binary properties from this scenario when an additional constraint is taken into account, namely that there is a distribution of total cluster masses set by the masses of the cloud cores from which the clusters form. Two distinct steps then determine final stellar masses - the choice of a cluster mass and the formation of the individual stars. We refer to this as a ``two-step'' IMF. Simple statistical arguments are used in this paper to show that a two-step IMF, combined with typical results from dynamic few-body system decay, tends to give better agreement between computed binary characteristics and observations than a one-step mass selection process.
Zhao, Wenle; Pauls, Keith
2016-04-01
Centralized outcome adjudication has been used widely in multicenter clinical trials in order to prevent potential biases and to reduce variations in important safety and efficacy outcome assessments. Adjudication procedures could vary significantly among different studies. In practice, the coordination of outcome adjudication procedures in many multicenter clinical trials remains as a manual process with low efficiency and high risk of delay. Motivated by the demands from two large clinical trial networks, a generic outcome adjudication module has been developed by the network's data management center within a homegrown clinical trial management system. In this article, the system design strategy and database structure are presented. A generic database model was created to transfer different adjudication procedures into a unified set of sequential adjudication steps. Each adjudication step was defined by one activate condition, one lock condition, one to five categorical data items to capture adjudication results, and one free text field for general comments. Based on this model, a generic outcome adjudication user interface and a generic data processing program were developed within a homegrown clinical trial management system to provide automated coordination of outcome adjudication. By the end of 2014, this generic outcome adjudication module had been implemented in 10 multicenter trials. A total of 29 adjudication procedures were defined with the number of adjudication steps varying from 1 to 7. The implementation of a new adjudication procedure in this generic module took an experienced programmer 1 or 2 days. A total of 7336 outcome events had been adjudicated and 16,235 adjudication step activities had been recorded. In a multicenter trial, 1144 safety outcome event submissions went through a three-step adjudication procedure and reported a median of 3.95 days from safety event case report form submission to adjudication completion. In another trial, 277 clinical outcome events were adjudicated by a six-step procedure and took a median of 23.84 days from outcome event case report form submission to adjudication procedure completion. A generic outcome adjudication module integrated in the clinical trial management system made the automated coordination of efficacy and safety outcome adjudication a reality. © The Author(s) 2015.
A Simple Class Exercise on Plate Tectonic Motion.
ERIC Educational Resources Information Center
Bates, Denis E. B.
1990-01-01
Presented is an activity in which students construct a model of plate divergence with two sheets of paper to show the separation of two continental plates in a system of spreading ridges and faults. Diagrams and procedures are described. (CW)
ERIC Educational Resources Information Center
Gilbert, George L., Ed.
1989-01-01
Presented are two demonstrations including a variation of the iodine clock reaction, and a simple demonstration of refractive index. The materials, procedures, and a discussion of probable results are given for each. (CW)
Using Three-Dimensional Printing to Fabricate a Tubing Connector for Dilation and Evacuation.
Stitely, Michael L; Paterson, Helen
2016-02-01
This is a proof-of-concept study to show that simple instrumentation problems encountered in surgery can be solved by fabricating devices using a three-dimensional printer. The device used in the study is a simple tubing connector fashioned to connect two segments of suction tubing used in a surgical procedure where no commercially available product for this use is available through our usual suppliers in New Zealand. A cylindrical tubing connector was designed using three-dimensional printing design software. The tubing connector was fabricated using the Makerbot Replicator 2X three-dimensional printer. The connector was used in 15 second-trimester dilation and evacuation procedures. Data forms were completed by the primary operating surgeon. Descriptive statistics were used with the expectation that the device would function as intended in all cases. The three-dimensional printed tubing connector functioned as intended in all 15 instances. Commercially available three-dimensional printing technology can be used to overcome simple instrumentation problems encountered during gynecologic surgical procedures.
Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum.
Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing
2014-05-01
Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of P. falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8-24 h followed by routine culture. When cultures with 27-60% of ring stage were synchronized using this procedure, 70-93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. Copyright © 2014 Elsevier Inc. All rights reserved.
Refrigeration provides a simple means to synchronize in vitro cultures of Plasmodium falciparum
Yuan, Lili; Hao, Mingming; Wu, Lanou; Zhao, Zhen; Rosenthal, Benjamin M.; Li, Xiaomei; He, Yongshu; Sun, Ling; Feng, Guohua; Xiang, Zheng; Cui, Liwang; Yang, Zhaoqing
2014-01-01
Plasmodium falciparum is usually asynchronous during in vitro culture. Highly synchronized cultures of Plasmodium falciparum are routinely used in malaria research. Here, we describe a simple synchronization procedure for P. falciparum asexual erythrocytic culture, which involves storage at 4°C for 8–24 h followed by routine culture. When cultures with 27–60% of ring stage were synchronized using this procedure, 70–93% ring stages were obtained after 48 h of culture and relative growth synchrony remained for at least two erythrocytic cycles. To test the suitability of this procedure for subsequent work, drug sensitivity assays were performed using four laboratory strains and four freshly adapted clinical P. falciparum isolates. Parasites synchronized by sorbitol treatment or refrigeration showed similar dose-response curves and comparable IC50 values to four antimalarial drugs. The refrigeration synchronization method is simple, inexpensive, time-saving, and should be especially useful when large numbers of P. falciparum culture are handled. PMID:24632190
Dwivedi, Jaya; Namdev, Kuldeep K; Chilkoti, Deepak C; Verma, Surajpal; Sharma, Swapnil
2018-06-06
Therapeutic drug monitoring (TDM) of anti-epileptic drugs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) is a suitable alternative to overcome these issues. An improved, simple, rapid, and stability indicating method for quantification of pregabalin in human plasma and DPS has been developed and validated. Analyses were performed on liquid chromatography tandem mass spectrometer under positive ionization mode of electrospray interface. Pregabain-d4 was used as internal standard, and the chromatographic separations were performed on Poroshell 120 EC-C18 column using an isocratic mobile phase flow rate of 1 mL/min. Stability of pregabalin in DPS was evaluated under simulated real-time conditions. Extraction procedures from plasma and DPS samples were compared using statistical tests. The method was validated considering the FDA method validation guideline. The method was linear over the concentration range of 20-16000 ng/mL and 100-10000 ng/mL in plasma and DPS, respectively. DPS samples were found stable for only one week upon storage at room temperature and for at least four weeks at freezing temperature (-20 ± 5 °C). Method was applied for quantification of pregabalin in over 600 samples of a clinical study. Statistical analyses revealed that two extraction procedures in plasma and DPS samples showed statistically insignificant difference and can be used interchangeably without any bias. Proposed method involves simple and rapid steps of sample processing that do not require a pre- or post-column derivatization procedure. The method is suitable for routine pharmacokinetic analysis and therapeutic monitoring of pregabalin.
Speak Out (K-8) [and] Election '80.
ERIC Educational Resources Information Center
Illinois State Board of Education, Springfield.
These two teaching guides contain step-by-step procedures for an election education program in which all Illinois school children vote for and elect a State animal. The program, mandated by the Illinois State Legislature, is intended to provide students with the unique opportunity to learn about the entire election process through actual voting…
RBS Career Education. Evaluation Planning Manual. Education Is Going to Work.
ERIC Educational Resources Information Center
Kershner, Keith M.
Designed for use with the Research for Better Schools career education program, this evaluation planning manual focuses on procedures and issues central to planning the evaluation of an educational program. Following a statement on the need for evaluation, nine sequential steps for evaluation planning are discussed. The first two steps, program…
Bayesian SEM for Specification Search Problems in Testing Factorial Invariance.
Shi, Dexin; Song, Hairong; Liao, Xiaolan; Terry, Robert; Snyder, Lori A
2017-01-01
Specification search problems refer to two important but under-addressed issues in testing for factorial invariance: how to select proper reference indicators and how to locate specific non-invariant parameters. In this study, we propose a two-step procedure to solve these issues. Step 1 is to identify a proper reference indicator using the Bayesian structural equation modeling approach. An item is selected if it is associated with the highest likelihood to be invariant across groups. Step 2 is to locate specific non-invariant parameters, given that a proper reference indicator has already been selected in Step 1. A series of simulation analyses show that the proposed method performs well under a variety of data conditions, and optimal performance is observed under conditions of large magnitude of non-invariance, low proportion of non-invariance, and large sample sizes. We also provide an empirical example to demonstrate the specific procedures to implement the proposed method in applied research. The importance and influences are discussed regarding the choices of informative priors with zero mean and small variances. Extensions and limitations are also pointed out.
NASA Astrophysics Data System (ADS)
Krasilenko, Vladimir G.; Nikolsky, Alexander I.; Zaitsev, Alexandr V.; Voloshin, Victor M.
2001-03-01
Historic information regarding the appearance and creation of fundamentals of algebra-logical apparatus-`equivalental algebra' for description of neuro-nets paradigms and algorithms is considered which is unification of theory of neuron nets (NN), linear algebra and the most generalized neuro-biology extended for matrix case. A survey is given of `equivalental models' of neuron nets and associative memory is suggested new, modified matrix-tenzor neurological equivalental models (MTNLEMS) are offered with double adaptive-equivalental weighing (DAEW) for spatial-non- invariant recognition (SNIR) and space-invariant recognition (SIR) of 2D images (patterns). It is shown, that MTNLEMS DAEW are the most generalized, they can describe the processes in NN both within the frames of known paradigms and within new `equivalental' paradigm of non-interaction type, and the computing process in NN under using the offered MTNLEMs DAEW is reduced to two-step and multi-step algorithms and step-by-step matrix-tenzor procedures (for SNIR) and procedures of defining of space-dependent equivalental functions from two images (for SIR).
Analysis and design of a standardized control module for switching regulators
NASA Astrophysics Data System (ADS)
Lee, F. C.; Mahmoud, M. F.; Yu, Y.; Kolecki, J. C.
1982-07-01
Three basic switching regulators: buck, boost, and buck/boost, employing a multiloop standardized control module (SCM) were characterized by a common small signal block diagram. Employing the unified model, regulator performances such as stability, audiosusceptibility, output impedance, and step load transient are analyzed and key performance indexes are expressed in simple analytical forms. More importantly, the performance characteristics of all three regulators are shown to enjoy common properties due to the unique SCM control scheme which nullifies the positive zero and provides adaptive compensation to the moving poles of the boost and buck/boost converters. This allows a simple unified design procedure to be devised for selecting the key SCM control parameters for an arbitrarily given power stage configuration and parameter values, such that all regulator performance specifications can be met and optimized concurrently in a single design attempt.
Du, Yuanqi; Xia, Ling; Xiao, Xiaohua; Li, Gongke; Chen, Xiaoguang
2018-06-15
Nowadays, the safety of cosmetics is a widespread concern. Amines are common cosmetic additives. Some of them such as amino acids are beneficial. Another kind of amines, however, ε-aminocaproic acid (EACA) is prohibited to add into cosmetics for its adverse reactions. In this study, a simple, rapid, sensitive and eco-friendly one-step ultrasonic-assisted extraction and derivatization (UAE-D) method was developed for determination of EACA and amino acids in cosmetics by coupling with high-performance liquid chromatography (HPLC). By using this sample preparation method, extraction and derivatization of EACA and amino acids were finished in one step in ultrasound field. During this procedure, 4-fluoro-7-nitrobenzofurazan (NBD-F)was applied as derivatization reagent. The extraction conditions including the amount of NBD-F, extraction and derivatization temperature, the ultrasonic vibration time and pH value of the aqueous phase were evaluated. Meanwhile, the extraction mechanism was investigated. Under optimized conditions, the method detection limits were 0.086-0.15 μg/L, and method quantitation limits were 0.29-0.47 μg/L with RSDs less than 3.7% (n = 3). The recoveries of EACA and amino acids obtained from cosmetic samples were in range from 76.9% to 122.3%. Amino acids were found in all selected samples and quantified in range from 1.9 ± 0.9 to 677.2 ± 17.9 μg/kg. And EACA was found and quantified with the contents of 1284.3 ± 22.1 μg/kg in a toner sample. This UAE-D-HPLC method shortened and simplified the sample pretreatment as well as enhanced the sensitivity of analytical method. In our record, only 10 min was needed for the total sample preparation process. And the method detection limits were two orders of magnitude less than literature reports. Furthermore, we reduced the consumption of solvent and minimized the usage of organic solvents, which made our method moving towards green analytical chemistry. In brief, our UAE-D-HPLC method is a simple, rapid, sensitive and eco-friendly analytical method for the determination of EACA and amino acids in cosmetics. Copyright © 2018 Elsevier B.V. All rights reserved.
Sanzò, Gabriella; Taurino, Irene; Puppo, Francesca; Antiochia, Riccarda; Gorton, Lo; Favero, Gabriele; Mazzei, Franco; Carrara, Sandro; De Micheli, Giovanni
2017-10-01
In this work, we have developed for the first time a method to make novel gold and platinum hybrid bimetallic nanostructures differing in shape and size. Au-Pt nanostructures were prepared by electrodeposition in two simple steps. The first step consists of the electrodeposition of nanocoral Au onto a gold substrate using hydrogen as a dynamic template in an ammonium chloride solution. After that, the Pt nanostructures were deposited onto the nanocoral Au organized in pores. Using Pt (II) and Pt (IV), we realized nanocoral Au decorated with Pt nanospheres and nanocoral Au decorated with Pt nanoflowers, respectively. The bimetallic nanostructures showed better capability to electrochemically oxidize hydrogen peroxide compared with nanocoral Au. Moreover, Au-Pt nanostructures were able to lower the potential of detection and a higher performance was obtained at a low applied potential. Then, glucose oxidase was immobilized onto the bimetallic Au-Pt nanostructure using cross-linking with glutaraldehyde. The biosensor was characterized by chronoamperometry at +0.15V vs. Ag pseudo-reference electrode (PRE) and showed good analytical performances with a linear range from 0.01 to 2.00mM and a sensitivity of 33.66µA/mMcm 2 . The good value of K m app (2.28mM) demonstrates that the hybrid nanostructure is a favorable environment for the enzyme. Moreover, the low working potential can minimize the interference from ascorbic acid and uric acid as well as reducing power consumption to effect sensing. The simple procedure to realize this nanostructure and to immobilize enzymes, as well as the analytical performances of the resulting devices, encourage the use of this technology for the development of biosensors for clinical analysis. Copyright © 2017. Published by Elsevier Inc.
Davison, James A
2015-01-01
To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer.
2013-03-28
positions leading us to utilize a two-step procedure in which the amines were treated with methylchloroformate before being fully reduced with lithium ...was carried out using lithium aluminum hydride before undergoing a similar two-step methylation as described above to yield bisferrocenyl ligand 16...of Ni-based complex 30. CV’s were ran in DCM with tetrabutylammonium hexafluorophosphate electrolyte and referenced to a ferrocene standard. In
A novel two-step procedure to expand Sca-1+ cells clonally
Tang, Yao Liang; Shen, Leping; Qian, Keping; Phillips, M. Ian
2007-01-01
Resident cardiac stem cells (CSCs) are characterized by their capacity to self-renew in culture, and are multi-potent for forming normal cell types in hearts. CSCs were originally isolated directly from enzymatically digested hearts using stem cell markers. However, long exposure to enzymatic digestion can affect the integrity of stem cell markers on the cell surface, and also compromise stem cell function. Alternatively resident CSCs can migrate from tissue explant and form cardiospheres in culture. However, fibroblast contamination can easily occur during CSC culture. To avoid these problems, we developed a two-step procedure by growing the cells before selecting the Sca1+ cells and culturing in cardiac fibroblast conditioned medium, they avoid fibroblast overgrowth. PMID:17577582
Hogendoorn, E A; Westhuis, K; Dijkman, E; Heusinkveld, H A; den Boer, A C; Evers, E A; Baumann, R A
1999-10-08
The coupled-column (LC-LC) configuration consisting of a 3 microm C18 column (50 x 4.6 mm I.D.) as the first column and a 5 microm C18 semi-permeable-surface (SPS) column (150 x 4.6 mm I.D.) as the second column appeared to be successful for the screening of acidic pesticides in surface water samples. In comparison to LC-LC employing two C18 columns, the combination of C18/SPS-C18 significantly decreased the baseline deviation caused by the hump of the co-extracted humic substances when using UV detection (217 nm). The developed LC-LC procedure allowed the simultaneous determination of the target analytes bentazone and bromoxynil in uncleaned extracts of surface water samples to a level of 0.05 microg/l in less than 15 min. In combination with a simple solid-phase extraction step (200 ml of water on a 500 mg C18-bonded silica) the analytical procedure provides a high sample throughput. During a period of about five months more than 200 ditch-water samples originating from agricultural locations were analyzed with the developed procedure. Validation of the method was performed by randomly analyzing recoveries of water samples spiked at levels of 0.1 microg/l (n=10), 0.5 microg/l (n=7) and 2.5 microg/l (n=4). Weighted regression of the recovery data showed that the method provides overall recoveries of 95 and 100% for bentazone and bromoxynil, respectively, with corresponding intra-laboratory reproducibilities of 10 and 11%, respectively. Confirmation of the analytes in part of the samples extracts was carried out with GC-negative ion chemical ionization MS involving a derivatization step with bis(trifluoromethyl)benzyl bromide. No false negatives or positives were observed.
Andereggen, Lukas; Neuschmelting, Volker; von Gunten, Michael; Widmer, Hans Rudolf; Takala, Jukka; Jakob, Stephan M; Fandino, Javier; Marbacher, Serge
2014-10-02
Early brain injury and delayed cerebral vasospasm both contribute to unfavorable outcomes after subarachnoid hemorrhage (SAH). Reproducible and controllable animal models that simulate both conditions are presently uncommon. Therefore, new models are needed in order to mimic human pathophysiological conditions resulting from SAH. This report describes the technical nuances of a rabbit blood-shunt SAH model that enables control of intracerebral pressure (ICP). An extracorporeal shunt is placed between the arterial system and the subarachnoid space, which enables examiner-independent SAH in a closed cranium. Step-by-step procedural instructions and necessary equipment are described, as well as technical considerations to produce the model with minimal mortality and morbidity. Important details required for successful surgical creation of this robust, simple and consistent ICP-controlled SAH rabbit model are described.
New adhesives and bonding techniques. Why and when?
Scotti, Nicola; Cavalli, Giovanni; Gagliani, Massimo; Breschi, Lorenzo
Nowadays, adhesive dentistry is a fundamental part of daily clinical work. The evolution of adhesive materials and techniques has been based on the need for simplicity in the step-by-step procedures to obtain long-lasting direct and indirect restorations. For this reason, recently introduced universal multimode adhesives represent a simple option for creating a hybrid layer, with or without the use of phosphoric acid application. However, it is important to understand the limitations of this latest generation of adhesive systems as well as how to use them on coronal and radicular dentin. Based on the findings in the literature, universal multimode adhesives have shown promising results, even if the problem of hybrid layer degradation due to the hydrolytic activity of matrix metalloproteinases (MMPs) still exists. Studies are therefore required to help us understand how to reduce this degradation.
Comparison of designed and randomly generated catalysts for simple chemical reactions.
Kipnis, Yakov; Baker, David
2012-09-01
There has been recent success in designing enzymes for simple chemical reactions using a two-step protocol. In the first step, a geometric matching algorithm is used to identify naturally occurring protein scaffolds at which predefined idealized active sites can be realized. In the second step, the residues surrounding the transition state model are optimized to increase transition state binding affinity and to bolster the primary catalytic side chains. To improve the design methodology, we investigated how the set of solutions identified by the design calculations relate to the overall set of solutions for two different chemical reactions. Using a TIM barrel scaffold in which catalytically active Kemp eliminase and retroaldolase designs were obtained previously, we carried out activity screens of random libraries made to be compositionally similar to active designs. A small number of active catalysts were found in screens of 10³ variants for each of the two reactions, which differ from the computational designs in that they reuse charged residues already present in the native scaffold. The results suggest that computational design considerably increases the frequency of catalyst generation for active sites involving newly introduced catalytic residues, highlighting the importance of interaction cooperativity in enzyme active sites. Copyright © 2012 The Protein Society.
Microwave-assisted one-step synthesis of white light-emitting carbon dot suspensions
NASA Astrophysics Data System (ADS)
Vanessa, Hinterberger; Wenshuo, Wang; Cornelia, Damm; Simon, Wawra; Martin, Thoma; Wolfgang, Peukert
2018-06-01
In this contribution, we demonstrate that an aqueous solution with adjustable fluorescent color, including white light emission, can be achieved by a rapid one-step microwave synthesis method resulting in a mixture of blue-emitting carbon dots (CDs) and the yellow-emitting 2,3-diaminophenazine (DAP). Aqueous mixtures of o-phenylene-diamine (oPD) and citric acid (CA) are used as precursors. The resulting product structures are analyzed by FT-IR and NMR spectroscopy and the size of the resulting CDs is determined by atomic force microscopy to be 1.1 ± 0.3 nm. The synthesized solution exhibits two fluorescence emission peaks at 430 and 560 nm, which were found to originate from the CDs and DAP, respectively. The intensity ratio of both fluorescence peaks depends on pH, which is driven by the protonation state of DAP. In consequence, the fluorescence emission color of the CD solution can be tuned precisely and reproducibly from blue to white to yellow by careful control of the pH. Finally, at a pH level of 5.4, at which there is equal blue and yellow emission intensity, a white light emitting solution can be successfully produced in a very fast and simple synthesis procedure.
Klancar, Gregor; Kristan, Matej; Kovacic, Stanislav; Orqueda, Omar
2004-07-01
In this paper a global vision scheme for estimation of positions and orientations of mobile robots is presented. It is applied to robot soccer application which is a fast dynamic game and therefore needs an efficient and robust vision system implemented. General applicability of the vision system can be found in other robot applications such as mobile transport robots in production, warehouses, attendant robots, fast vision tracking of targets of interest and entertainment robotics. Basic operation of the vision system is divided into two steps. In the first, the incoming image is scanned and pixels are classified into a finite number of classes. At the same time, a segmentation algorithm is used to find corresponding regions belonging to one of the classes. In the second step, all the regions are examined. Selection of the ones that are a part of the observed object is made by means of simple logic procedures. The novelty is focused on optimization of the processing time needed to finish the estimation of possible object positions. Better results of the vision system are achieved by implementing camera calibration and shading correction algorithm. The former corrects camera lens distortion, while the latter increases robustness to irregular illumination conditions.
Administering and Detecting Protein Marks on Arthropods for Dispersal Research.
Hagler, James R; Machtley, Scott A
2016-01-28
Monitoring arthropod movement is often required to better understand associated population dynamics, dispersal patterns, host plant preferences, and other ecological interactions. Arthropods are usually tracked in nature by tagging them with a unique mark and then re-collecting them over time and space to determine their dispersal capabilities. In addition to actual physical tags, such as colored dust or paint, various types of proteins have proven very effective for marking arthropods for ecological research. Proteins can be administered internally and/or externally. The proteins can then be detected on recaptured arthropods with a protein-specific enzyme-linked immunosorbent assay (ELISA). Here we describe protocols for externally and internally tagging arthropods with protein. Two simple experimental examples are demonstrated: (1) an internal protein mark introduced to an insect by providing a protein-enriched diet and (2) an external protein mark topically applied to an insect using a medical nebulizer. We then relate a step-by-step guide of the sandwich and indirect ELISA methods used to detect protein marks on the insects. In this demonstration, various aspects of the acquisition and detection of protein markers on arthropods for mark-release-recapture, mark-capture, and self-mark-capture types of research are discussed, along with the various ways that the immunomarking procedure has been adapted to suit a wide variety of research objectives.
Problem-Solving Test: Submitochondrial Localization of Proteins
ERIC Educational Resources Information Center
Szeberenyi, Jozsef
2011-01-01
Mitochondria are surrounded by two membranes (outer and inner mitochondrial membrane) that separate two mitochondrial compartments (intermembrane space and matrix). Hundreds of proteins are distributed among these submitochondrial components. A simple biochemical/immunological procedure is described in this test to determine the localization of…
The DESTIN: Preservice Teachers' Drawings of the Ideal Elementary Science Teacher
ERIC Educational Resources Information Center
Mensah, Felicia Moore
2011-01-01
The aim of this study is to report findings from the Drawing-Elementary-Science-Teacher-Ideal-Not, or the DESTIN procedure. The study utilizes a simple drawing procedure accompanied by a narrative and discussion for understanding preservice teachers' images of science, science teaching, and the science teacher. Ninety drawings from two sections of…
Zuo, Peng; Li, XiuJun; Dominguez, Delfina C; Ye, Bang-Ce
2013-10-07
Infectious pathogens often cause serious public health concerns throughout the world. There is an increasing demand for simple, rapid and sensitive approaches for multiplexed pathogen detection. In this paper we have developed a polydimethylsiloxane (PDMS)/paper/glass hybrid microfluidic system integrated with aptamer-functionalized graphene oxide (GO) nano-biosensors for simple, one-step, multiplexed pathogen detection. The paper substrate used in this hybrid microfluidic system facilitated the integration of aptamer biosensors on the microfluidic biochip, and avoided complicated surface treatment and aptamer probe immobilization in a PDMS or glass-only microfluidic system. Lactobacillus acidophilus was used as a bacterium model to develop the microfluidic platform with a detection limit of 11.0 cfu mL(-1). We have also successfully extended this method to the simultaneous detection of two infectious pathogens - Staphylococcus aureus and Salmonella enterica. This method is simple and fast. The one-step 'turn on' pathogen assay in a ready-to-use microfluidic device only takes ~10 min to complete on the biochip. Furthermore, this microfluidic device has great potential in rapid detection of a wide variety of different other bacterial and viral pathogens.
Zuo, Peng; Dominguez, Delfina C.; Ye, Bang-Ce
2014-01-01
Infectious pathogens often cause serious public health concerns throughout the world. There is an increasing demand for simple, rapid and sensitive approaches for multiplexed pathogen detection. In this paper we have developed a polydimethylsiloxane (PDMS)/paper/glass hybrid microfluidic system integrated with aptamer-functionalized graphene oxide (GO) nano-biosensors for simple, one-step, multiplexed pathogen detection. The paper substrate used in this hybrid microfluidic system facilitated the integration of aptamer biosensors on the microfluidic biochip, and avoided complicated surface treatment and aptamer probe immobilization in a PDMS or glass-only microfluidic system. Lactobacillus acidophilus was used as a bacterium model to develop the microfluidic platform with a detection limit of 11.0 cfu mL−1. We have also successfully extended this method to the simultaneous detection of two infectious pathogens - Staphylococcus aureus and Salmonella enterica. This method is simple and fast. The one-step ‘turn on’ pathogen assay in a ready-to-use microfluidic device only takes ~10 min to complete on the biochip. Furthermore, this microfluidic device has great potential in rapid detection of a wide variety of different other bacterial and viral pathogens. PMID:23929394
Tetraethylene glycol promoted two-step, one-pot rapid synthesis of indole-3-[1- 11C]acetic acid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sojeong; Qu, Wenchao; Alexoff, David L.
2014-12-12
An operationally friendly, two-step, one-pot process has been developed for the rapid synthesis of carbon-11 labeled indole-3-acetic acid ([ 11]IAA or [ 11]auxin). By replacing an aprotic polar solvent with tetraethylene glycol, nucleophilic [ 11]cyanation and alkaline hydrolysis reactions were performed consecutively in a single pot without a time-consuming intermediate purification step. The entire production time for this updated procedure is 55 min, which dramatically simplifies the entire synthesis and reduces the starting radioactivity required for a whole plant imaging study.
Regularized lattice Boltzmann model for immiscible two-phase flows with power-law rheology
NASA Astrophysics Data System (ADS)
Ba, Yan; Wang, Ningning; Liu, Haihu; Li, Qiang; He, Guoqiang
2018-03-01
In this work, a regularized lattice Boltzmann color-gradient model is developed for the simulation of immiscible two-phase flows with power-law rheology. This model is as simple as the Bhatnagar-Gross-Krook (BGK) color-gradient model except that an additional regularization step is introduced prior to the collision step. In the regularization step, the pseudo-inverse method is adopted as an alternative solution for the nonequilibrium part of the total distribution function, and it can be easily extended to other discrete velocity models no matter whether a forcing term is considered or not. The obtained expressions for the nonequilibrium part are merely related to macroscopic variables and velocity gradients that can be evaluated locally. Several numerical examples, including the single-phase and two-phase layered power-law fluid flows between two parallel plates, and the droplet deformation and breakup in a simple shear flow, are conducted to test the capability and accuracy of the proposed color-gradient model. Results show that the present model is more stable and accurate than the BGK color-gradient model for power-law fluids with a wide range of power-law indices. Compared to its multiple-relaxation-time counterpart, the present model can increase the computing efficiency by around 15%, while keeping the same accuracy and stability. Also, the present model is found to be capable of reasonably predicting the critical capillary number of droplet breakup.
Kharade, Pankaj; Banerjee, Ardhendu; Gupta, Tapas
2012-01-01
A diagnostic radiograph of the posterior regions of the jaws is mandatory if implant placement is considered at these sites. The goal is to avoid damage to important anatomical structures such as the inferior alveolar canal and maxillary sinus. Using radiographs to evaluate the remaining bone height available for implant insertion is a common procedure. Many articles have evaluated the success rates of fixed prostheses supported by osseointegrated implants, indicating high rates of success for prostheses 5-10 years in function. However, if an orthopantomogram machine is not readily available, periapical radiographs can be used for vertical bone height assessment. The familiar procedure of incorporating a metal ball of known diameter into an acrylic template is the method of choice. This is a relatively tedious and expensive procedure involving multiple steps, including impression taking, creation of a study model, and manufacture of a metal ball-bearing acrylic template. A further disadvantage for the patient is that a diagnostic radiograph can be taken only at the next appointment. This paper describes a quick and simple method to obtain a radiographic evaluation of remaining alveolar bone height and soft tissue thickness prior to implant placement with help of a metal ball device to avoid template fabrication and time consumption. Soft tissue thickness is measured nonsurgically.
Gupta, Nimisha; Tripathi, Abhay Mani; Saha, Sonali; Dhinsa, Kavita; Garg, Aarti
2015-07-01
Newer development of bonding agents have gained a better understanding of factors affecting adhesion of interface between composite and dentin surface to improve longevity of restorations. The present study evaluated the influence of salivary contamination on the tensile bond strength of different generation adhesive systems (two-step etch-and-rinse, two-step self-etch and one-step self-etch) during different bonding stages to dentin where isolation is not maintained. Superficial dentin surfaces of 90 extracted human molars were randomly divided into three study Groups (Group A: Two-step etch-and-rinse adhesive system; Group B: Two-step self-etch adhesive system and Group C: One-step self-etch adhesive system) according to the different generation of adhesives used. According to treatment conditions in different bonding steps, each Group was further divided into three Subgroups containing ten teeth in each. After adhesive application, resin composite blocks were built on dentin and light cured subsequently. The teeth were then stored in water for 24 hours before sending for testing of tensile bond strength by Universal Testing Machine. The collected data were then statistically analysed using one-way ANOVA and Tukey HSD test. One-step self-etch adhesive system revealed maximum mean tensile bond strength followed in descending order by Two-step self-etch adhesive system and Two-step etch-and-rinse adhesive system both in uncontaminated and saliva contaminated conditions respectively. Unlike One-step self-etch adhesive system, saliva contamination could reduce tensile bond strength of the two-step self-etch and two-step etch-and-rinse adhesive system. Furthermore, the step of bonding procedures and the type of adhesive seems to be effective on the bond strength of adhesives contaminated with saliva.
Modeling ultrasound propagation through material of increasing geometrical complexity.
Odabaee, Maryam; Odabaee, Mostafa; Pelekanos, Matthew; Leinenga, Gerhard; Götz, Jürgen
2018-06-01
Ultrasound is increasingly being recognized as a neuromodulatory and therapeutic tool, inducing a broad range of bio-effects in the tissue of experimental animals and humans. To achieve these effects in a predictable manner in the human brain, the thick cancellous skull presents a problem, causing attenuation. In order to overcome this challenge, as a first step, the acoustic properties of a set of simple bone-modeling resin samples that displayed an increasing geometrical complexity (increasing step sizes) were analyzed. Using two Non-Destructive Testing (NDT) transducers, we found that Wiener deconvolution predicted the Ultrasound Acoustic Response (UAR) and attenuation caused by the samples. However, whereas the UAR of samples with step sizes larger than the wavelength could be accurately estimated, the prediction was not accurate when the sample had a smaller step size. Furthermore, a Finite Element Analysis (FEA) performed in ANSYS determined that the scattering and refraction of sound waves was significantly higher in complex samples with smaller step sizes compared to simple samples with a larger step size. Together, this reveals an interaction of frequency and geometrical complexity in predicting the UAR and attenuation. These findings could in future be applied to poro-visco-elastic materials that better model the human skull. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
A triangular thin shell finite element: Nonlinear analysis. [structural analysis
NASA Technical Reports Server (NTRS)
Thomas, G. R.; Gallagher, R. H.
1975-01-01
Aspects of the formulation of a triangular thin shell finite element which pertain to geometrically nonlinear (small strain, finite displacement) behavior are described. The procedure for solution of the resulting nonlinear algebraic equations combines a one-step incremental (tangent stiffness) approach with one iteration in the Newton-Raphson mode. A method is presented which permits a rational estimation of step size in this procedure. Limit points are calculated by means of a superposition scheme coupled to the incremental side of the solution procedure while bifurcation points are calculated through a process of interpolation of the determinants of the tangent-stiffness matrix. Numerical results are obtained for a flat plate and two curved shell problems and are compared with alternative solutions.
Oranges, Posters, Ribbons, and Lemonade: Concrete Computational Strategies for Dividing Fractions
ERIC Educational Resources Information Center
Kribs-Zaleta, Christopher M.
2008-01-01
This article describes how sixth-grade students developed concrete models to solve division of fractions story problems. Students developed separate two-step procedures to solve measurement and partitive problems, drawing on invented procedures for division of whole numbers. Errors also tended to be specific to the type of division problem…
Constales, Denis; Yablonsky, Gregory S.; Wang, Lucun; ...
2017-04-25
This paper presents a straightforward and user-friendly procedure for extracting a reactivity characterization of catalytic reactions on solid materials under non-steady-state conditions, particularly in temporal analysis of products (TAP) experiments. The kinetic parameters derived by this procedure can help with the development of detailed mechanistic understanding. The procedure consists of the following two major steps: 1) Three “Laplace reactivities” are first determined based on the moments of the exit flow pulse response data; 2) Depending on a select kinetic model, kinetic constants of elementary reaction steps can then be expressed as a function of reactivities and determined accordingly. In particular,more » we distinguish two calculation methods based on the availability and reliability of reactant and product data. The theoretical results are illustrated using a reverse example with given parameters as well as an experimental example of CO oxidation over a supported Au/SiO 2 catalyst. The procedure presented here provides an efficient tool for kinetic characterization of many complex chemical reactions.« less
Lima, Juliana Maria; Salmazo Vieira, Plínio; Cavalcante de Oliveira, Arthur Henrique; Cardoso, Carmen Lúcia
2016-08-07
Nucleoside diphosphate kinase from Leishmania spp. (LmNDKb) has recently been described as a potential drug target to treat leishmaniasis disease. Therefore, screening of LmNDKb ligands requires methodologies that mimic the conditions under which LmNDKb acts in biological systems. Here, we compare two label-free methodologies that could help screen LmNDKb ligands and measure NDKb activity: an offline LC-UV assay for soluble LmNDKb and an online two-dimensional LC-UV system based on LmNDKb immobilised on a silica capillary. The target enzyme was immobilised on the silica capillary via Schiff base formation (to give LmNDKb-ICER-Schiff) or affinity attachment (to give LmNDKb-ICER-His). Several aspects of the ICERs resulting from these procedures were compared, namely kinetic parameters, stability, and procedure steps. Both the LmNDKb immobilisation routes minimised the conformational changes and preserved the substrate binding sites. However, considering the number of steps involved in the immobilisation procedure, the cost of reagents, and the stability of the immobilised enzyme, immobilisation via Schiff base formation proved to be the optimal procedure.
Several steps/day indicators predict changes in anthropometric outcomes: HUB city steps
USDA-ARS?s Scientific Manuscript database
Walking for exercise remains the most frequently reported leisure-time activity, likely because it is simple, inexpensive, and easily incorporated into most people’s lifestyle. Pedometers are simple, convenient, and economical tools that can be used to quantify step-determined physical activity. F...
NASA Astrophysics Data System (ADS)
Chahinian, Nanée; Moussa, Roger; Andrieux, Patrick; Voltz, Marc
2006-07-01
Tillage operations are known to greatly influence local overland flow, infiltration and depressional storage by altering soil hydraulic properties and soil surface roughness. The calibration of runoff models for tilled fields is not identical to that of untilled fields, as it has to take into consideration the temporal variability of parameters due to the transient nature of surface crusts. In this paper, we seek the application of a rainfall-runoff model and the development of a calibration methodology to take into account the impact of tillage on overland flow simulation at the scale of a tilled plot (3240 m 2) located in southern France. The selected model couples the (Morel-Seytoux, H.J., 1978. Derivation of equations for variable rainfall infiltration. Water Resources Research. 14(4), 561-568). Infiltration equation to a transfer function based on the diffusive wave equation. The parameters to be calibrated are the hydraulic conductivity at natural saturation Ks, the surface detention Sd and the lag time ω. A two-step calibration procedure is presented. First, eleven rainfall-runoff events are calibrated individually and the variability of the calibrated parameters are analysed. The individually calibrated Ks values decrease monotonously according to the total amount of rainfall since tillage. No clear relationship is observed between the two parameters Sd and ω, and the date of tillage. However, the lag time ω increases inversely with the peakflow of the events. Fairly good agreement is observed between the simulated and measured hydrographs of the calibration set. Simple mathematical laws describing the evolution of Ks and ω are selected, while Sd is considered constant. The second step involves the collective calibration of the law of evolution of each parameter on the whole calibration set. This procedure is calibrated on 11 events and validated on ten runoff inducing and four non-runoff inducing rainfall events. The suggested calibration methodology seems robust and can be transposed to other gauged sites.
A simple graphical method for measuring inherent safety.
Gupta, J P; Edwards, David W
2003-11-14
Inherently safer design (ISD) concepts have been with us for over two decades since their elaboration by Kletz [Chem. Ind. 9 (1978) 124]. Interest has really taken off globally since the early nineties after several major mishaps occurred during the eighties (Bhopal, Mexico city, Piper-alfa, Philips Petroleum, to name a few). Academic and industrial research personnel have been actively involved into devising inherently safer ways of production. The regulatory bodies have also shown deep interest since ISD makes the production safer and hence their tasks easier. Research funding has also been forthcoming for new developments as well as for demonstration projects.A natural question that arises is as to how to measure ISD characteristics of a process? Several researchers have worked on this [Trans. IChemE, Process Safety Environ. Protect. B 71 (4) (1993) 252; Inherent safety in process plant design, Ph.D. Thesis, VTT Publication Number 384, Helsinki University of Technology, Espoo, Finland, 1999; Proceedings of the Mary Kay O'Connor Process Safety Center Symposium, 2001, p. 509]. Many of the proposed methods are very elegant, yet too involved for easy adoption by the industry which is scared of yet another safety analysis regime. In a recent survey [Trans. IChemE, Process Safety Environ. Prog. B 80 (2002) 115], companies desired a rather simple method to measure ISD. Simplification is also an important characteristic of ISD. It is therefore desirable to have a simple ISD measurement procedure. The ISD measurement procedure proposed in this paper can be used to differentiate between two or more processes for the same end product. The salient steps are: Consider each of the important parameters affecting the safety (e.g., temperature, pressure, toxicity, flammability, etc.) and the range of possible values these parameters can have for all the process routes under consideration for an end product. Plot these values for each step in each process route and compare. No addition of values for disparate hazards (temperature, pressure, inventory, toxicity, flammability, etc.) is being suggested to derive an overall ISD index value since that conceals the effects of different parameters. Further, addition of numbers with different units ( degrees C for temperature, atm/bar for pressure, t for inventory, etc.) is inappropriate in scientific sense. The proposed approach has a major advantage of expanding consideration in future to incorporate economic, regulatory, pollution control and worker health aspects, as well as factors such as the experience one has or 'the comfort level' one feels with each of the processes under consideration. Additionally, it would also guide the designers and decision makers into affecting specific changes in the processes to reduce the unsafe features. We demonstrate our simple approach by using the example of six routes to make methyl methacrylate as documented by Edwards and Lawrence [Trans. IChemE, Process Safety Environ. Protect. B 71 (4) (1993) 252; Quantifying inherent safety of chemical process routes, Ph.D. Thesis, Loughborough University, Loughborough, UK, 1996] and show that the decision could well have been different if addition of disparate hazards had not been done.
NASA Astrophysics Data System (ADS)
Scharfenberg, Franz-Josef; Bogner, Franz X.
2011-08-01
Emphasis on improving higher level biology education continues. A new two-step approach to the experimental phases within an outreach gene technology lab, derived from cognitive load theory, is presented. We compared our approach using a quasi-experimental design with the conventional one-step mode. The difference consisted of additional focused discussions combined with students writing down their ideas (step one) prior to starting any experimental procedure (step two). We monitored students' activities during the experimental phases by continuously videotaping 20 work groups within each approach ( N = 131). Subsequent classification of students' activities yielded 10 categories (with well-fitting intra- and inter-observer scores with respect to reliability). Based on the students' individual time budgets, we evaluated students' roles during experimentation from their prevalent activities (by independently using two cluster analysis methods). Independently of the approach, two common clusters emerged, which we labeled as `all-rounders' and as `passive students', and two clusters specific to each approach: `observers' as well as `high-experimenters' were identified only within the one-step approach whereas under the two-step conditions `managers' and `scribes' were identified. Potential changes in group-leadership style during experimentation are discussed, and conclusions for optimizing science teaching are drawn.
Two-step solar filament eruptions
NASA Astrophysics Data System (ADS)
Filippov, B.
2018-04-01
Coronal mass ejections (CMEs) are closely related to eruptive filaments and usually are the continuation of the same eruptive process into the upper corona. There are failed filament eruptions when a filament decelerates and stops at some greater height in the corona. Sometimes the filament after several hours starts to rise again and develops into the successful eruption with a CME formation. We propose a simple model for the interpretation of such two-step eruptions in terms of equilibrium of a flux rope in a two-scale ambient magnetic field. The eruption is caused by a slow decrease of the holding magnetic field. The presence of two critical heights for the initiation of the flux-rope vertical instability allows the flux rope to stay after the first jump some time in a metastable equilibrium near the second critical height. If the decrease of the ambient field continues, the next eruption step follows.
Use of the earlobe in auricular reconstruction post tumour extirpation.
Chadha, A; Grob, M; Soldin, M
2009-04-01
The exact location and topography of defects resulting from surgical excision of cutaneous malignancies of the auricle demand a customized approach based on an awareness of locally redundant tissue. With advancing age, the earlobe becomes ideal for this reconstructive role and we describe an earlobe flap created along the longitudinal axis of lobular tissue. This reliable, simple, one-step procedure provides adequate tissue cover for defects of the antitragus and adjoining concha. Flap vascularity is satisfactory and although the overall size of the ear is reduced, this is accepted for a rejuvenated shape and minimal morbidity.
Synthesis of racemic β-chamigrene, a spiro[5.5]undecane sequiterpene.
Antonsen, Simen; Skattebøl, Lars; Stenstrøm, Yngve
2014-12-10
The present paper describes a total synthesis of racemic β-chamigrene, a sesquiterpene with a spiro[5.5]undecane carbon framework. Compared with previously reported β-chamigrene syntheses, we were able to reduce the total number of reaction steps, which also resulted in a significant improvement of the overall yield. The commercially available ketone 6-methylhept-5-en-2-one was transformed by known simple procedures into 3,3-dimethyl-2-methylenecyclohexanone. This reacted with isoprene by a Diels-Alder reaction to give a spiro ketone. An olefination reaction on this compound gave the target molecule.
NASA Astrophysics Data System (ADS)
Sun, Xuzhuo; Li, Bo; Lu, Mingxia
2017-07-01
Chemical modification of graphene is a promising approach to manipulate its properties for its end applications. Herein we designed a two-step route through chlorination-Grignard reactions to covalently decorate the surface of graphene with adamantane groups. The chemically modified graphene was characterized by Raman spectroscopy, atomic force microscopy, and X-ray photoelectron spectroscopy. Chlorination of graphene occurred rapidly, and the substitution of chlorine atoms on chlorinated graphene by adamantane Grignard reagent afforded adamantane graphene in almost quantitative yield. Adamantane groups were found to be covalently bonded to the graphene carbons. The present two-step procedure may provide an effective and facile route for graphene modification with varieties of organic functional groups.
NASA Technical Reports Server (NTRS)
Molnar, Melissa; Marek, C. John
2004-01-01
A simplified kinetic scheme for Jet-A, and methane fuels with water injection was developed to be used in numerical combustion codes, such as the National Combustor Code (NCC) or even simple FORTRAN codes that are being developed at Glenn. The two time step method is either an initial time averaged value (step one) or an instantaneous value (step two). The switch is based on the water concentration in moles/cc of 1x10(exp -20). The results presented here results in a correlation that gives the chemical kinetic time as two separate functions. This two step method is used as opposed to a one step time averaged method previously developed to determine the chemical kinetic time with increased accuracy. The first time averaged step is used at the initial times for smaller water concentrations. This gives the average chemical kinetic time as a function of initial overall fuel air ratio, initial water to fuel mass ratio, temperature, and pressure. The second instantaneous step, to be used with higher water concentrations, gives the chemical kinetic time as a function of instantaneous fuel and water mole concentration, pressure and temperature (T4). The simple correlations would then be compared to the turbulent mixing times to determine the limiting properties of the reaction. The NASA Glenn GLSENS kinetics code calculates the reaction rates and rate constants for each species in a kinetic scheme for finite kinetic rates. These reaction rates were then used to calculate the necessary chemical kinetic times. Chemical kinetic time equations for fuel, carbon monoxide and NOx were obtained for Jet-A fuel and methane with and without water injection to water mass loadings of 2/1 water to fuel. A similar correlation was also developed using data from NASA's Chemical Equilibrium Applications (CEA) code to determine the equilibrium concentrations of carbon monoxide and nitrogen oxide as functions of overall equivalence ratio, water to fuel mass ratio, pressure and temperature (T3). The temperature of the gas entering the turbine (T4) was also correlated as a function of the initial combustor temperature (T3), equivalence ratio, water to fuel mass ratio, and pressure.
Sardiwalla, Yaeesh; Jufas, Nicholas; Morris, David P
2017-06-12
Minimally Invasive Ponto Surgery (MIPS) was recently described as a new technique to facilitate the placement of percutaneous bone anchored hearing devices. The procedure has resulted in a simplification of the surgical steps and a dramatic reduction in surgical time while maintaining excellent patient outcomes. Given these developments, our group sought to move the procedure from the main operating suite where they have traditionally been performed. This study aims to test the null hypothesis that MIPS and open approaches have the same direct costs for the implantation of percutaneous bone anchored hearing devices in a Canadian public hospital setting. A retrospective direct cost comparison of MIPS and open approaches for the implantation of bone conduction implants was conducted. Indirect and future costs were not included in the fiscal analysis. A simple cost comparison of the two approaches was made considering time, staff and equipment needs. All 12 operations were performed on adult patients from 2013 to 2016 by the same surgeon at a single hospital site. MIPS has a total mean reduction in cost of CAD$456.83 per operation from the hospital perspective when compared to open approaches. The average duration of the MIPS operation was 7 min, which is on average 61 min shorter compared with open approaches. The MIPS technique was more cost effective than traditional open approaches. This primarily reflects a direct consequence of a reduction in surgical time, with further contributions from reduced staffing and equipment costs. This simple, quick intervention proved to be feasible when performed outside the main operating room. A blister pack of required equipment could prove convenient and further reduce costs.
A simple, less invasive stripper micropipetter-based technique for day 3 embryo biopsy.
Cedillo, Luciano; Ocampo-Bárcenas, Azucena; Maldonado, Israel; Valdez-Morales, Francisco J; Camargo, Felipe; López-Bayghen, Esther
2016-01-01
Preimplantation genetic screening (PGS) is an important procedure for in vitro fertilization (IVF). A key step of PGS, blastomere removal, is abundant with many technical issues. The aim of this study was to compare a more simple procedure based on the Stipper Micropipetter, named S-biopsy, to the conventional aspiration method. On Day 3, 368 high-quality embryos (>7 cells on Day3 with <10% fragmentation) were collected from 38 women. For each patient, their embryos were equally separated between the conventional method ( n = 188) and S-biopsy method ( n = 180). The conventional method was performed using a standardized protocol. For the S-biopsy method, a laser was used to remove a significantly smaller portion of the zona pellucida. Afterwards, the complete embryo was aspirated with a Stripper Micropipetter, forcing the removal of the blastomere. Selected blastomeres went to PGS using CGH microarrays. Embryo integrity and blastocyst formation were assessed on Day 5. Differences between groups were assessed by either the Mann-Whitney test or Fisher Exact test. Both methods resulted in the removal of only one blastomere. The S-biopsy and the conventional method did not differ in terms of affecting embryo integrity (95.0% vs. 95.7%) or blastocyst formation (72.7% vs. 70.7%). PGS analysis indicated that aneuploidy rate were similar between the two methods (63.1% vs. 65.2%). However, the time required to perform the S-biopsy method (179.2 ± 17.5 s) was significantly shorter (5-fold) than the conventional method. The S-biopsy method is comparable to the conventional method that is used to remove a blastomere for PGS, but requires less time. Furthermore, due to the simplicity of the S-biopsy technique, this method is more ideal for IVF laboratories.
The Synthesis of 2-acetyl-1,4-naphthoquinone: A Multi-step Synthesis.
ERIC Educational Resources Information Center
Green, Ivan R.
1982-01-01
Outlines 2 procedures for synthesizing 2-acetyl-1,4-naphthoquinone to compare relative merits of the two pathways. The major objective of the exercise is to demonstrate that certain factors should be considered when selecting a pathway for synthesis including availability of starting materials, cost of reagents, number of steps involved,…
Woodrow Wilson and the U.S. Ratification of the Treaty of Versailles. Lesson Plan.
ERIC Educational Resources Information Center
Pyne, John; Sesso, Gloria
1995-01-01
Presents a high school lesson plan on the struggle over ratification of the Treaty of Versailles and U.S. participation in the League of Nations. Includes a timeline of events, four primary source documents, and biographical portraits of two opposing senators. Provides student objectives and step-by-step instructional procedures. (CFR)
Computer-Based Feedback in Linear Algebra: Effects on Transfer Performance and Motivation
ERIC Educational Resources Information Center
Corbalan, Gemma; Paas, Fred; Cuypers, Hans
2010-01-01
Two studies investigated the effects on students' perceptions (Study 1) and learning and motivation (Study 2) of different levels of feedback in mathematical problems. In these problems, an error made in one step of the problem-solving procedure will carry over to the following steps and consequently to the final solution. Providing immediate…
Yi, Gihwan; Choi, Jun-Ho; Lee, Jong-Hee; Jeong, Unggi; Nam, Min-Hee; Yun, Doh-Won; Eun, Moo-Young
2005-01-01
We describe a rapid and simple procedure for homogenizing leaf samples suitable for mini/midi-scale DNA preparation in rice. The methods used tungsten carbide beads and general vortexer for homogenizing leaf samples. In general, two samples can be ground completely within 11.3+/-1.5 sec at one time. Up to 20 samples can be ground at a time using a vortexer attachment. The yields of the DNA ranged from 2.2 to 7.6 microg from 25-150 mg of young fresh leaf tissue. The quality and quantity of DNA was compatible for most of PCR work and RFLP analysis.
Campos-Filho, N; Franco, E L
1989-02-01
A frequent procedure in matched case-control studies is to report results from the multivariate unmatched analyses if they do not differ substantially from the ones obtained after conditioning on the matching variables. Although conceptually simple, this rule requires that an extensive series of logistic regression models be evaluated by both the conditional and unconditional maximum likelihood methods. Most computer programs for logistic regression employ only one maximum likelihood method, which requires that the analyses be performed in separate steps. This paper describes a Pascal microcomputer (IBM PC) program that performs multiple logistic regression by both maximum likelihood estimation methods, which obviates the need for switching between programs to obtain relative risk estimates from both matched and unmatched analyses. The program calculates most standard statistics and allows factoring of categorical or continuous variables by two distinct methods of contrast. A built-in, descriptive statistics option allows the user to inspect the distribution of cases and controls across categories of any given variable.
Ryan, Daniel P; Tremethick, David J
2016-04-01
Linker histones are an abundant and critical component of the eukaryotic chromatin landscape. They play key roles in regulating the higher order structure of chromatin and many genetic processes. Higher eukaryotes possess a number of different linker histone subtypes and new data are consistently emerging that indicate these subtypes are functionally distinct. We were interested in studying one of the most abundant human linker histone subtypes, H1.4. We have produced recombinant full-length H1.4 in Escherichia coli. An N-terminal Glutathione-S-Transferase tag was used to promote soluble expression and was combined with a C-terminal hexahistidine tag to facilitate a simple non-denaturing two-step affinity chromatography procedure that results in highly pure full-length H1.4. The purified H1.4 was shown to be functional via in vitro chromatin assembly experiments and remains active after extended storage at -80 °C. Copyright © 2015 Elsevier Inc. All rights reserved.
Gregus, Michal; Roberg-Larsen, Hanne; Lundanes, Elsa; Foret, Frantisek; Kuban, Petr; Wilson, Steven Ray
2017-10-01
Capillary electrophoresis (CE) can provide high separation efficiency with very simple instrumentation, but has yet to be explored regarding oxysterols/cholesterol. Cholesterol and 25-hydroxycholesterol (both are 4-ene-3-ketosteroids) were quantitatively transformed into hydrazones using Girard P reagent after enzymatic oxidation by cholesterol oxidase. Separation was achieved using non-aqueous capillary electrophoresis with UV detection at 280nm; the "charge-tagging" Girard P reagent ensured both charge and chromophore (which are requirements for CE-UV). Excess reagent was also separated from the two analytes, eliminating the need for removal prior to the analysis. The compounds were separated in less than 5min with excellent separation efficiency, using separation electrolytes fully compatible with mass spectrometry. The CE-UV method was used to optimize steps for charge-tagging, revealing that the procedure is affected by the analyte/reagent ratio and reaction time, but also the analyte structure. Copyright © 2017 Elsevier B.V. All rights reserved.
Optimal design of an alignment-free two-DOF rehabilitation robot for the shoulder complex.
Galinski, Daniel; Sapin, Julien; Dehez, Bruno
2013-06-01
This paper presents the optimal design of an alignment-free exoskeleton for the rehabilitation of the shoulder complex. This robot structure is constituted of two actuated joints and is linked to the arm through passive degrees of freedom (DOFs) to drive the flexion-extension and abduction-adduction movements of the upper arm. The optimal design of this structure is performed through two steps. The first step is a multi-objective optimization process aiming to find the best parameters characterizing the robot and its position relative to the patient. The second step is a comparison process aiming to select the best solution from the optimization results on the basis of several criteria related to practical considerations. The optimal design process leads to a solution outperforming an existing solution on aspects as kinematics or ergonomics while being more simple.
Isolation of Biliverdin Ixa, as Its Dimethyl Ester, from Emu Eggshells
ERIC Educational Resources Information Center
Halepas, Steven; Hamchand, Randy; Lindeyer, Samuel E. D.; Bru¨ckner, Christian
2017-01-01
A laboratory experiment is described that extracts the tetrapyrrolic teal-colored biliverdin IXa, as its dimethyl ester, from commercially available emu eggshells. The extraction of ~10 mg samples of biliverdin is simple and requires two 3 h lab periods: A two-step acid digestion and liquid-liquid extraction, followed by short silica gel flash…
Mueller, D; Kulkarni, Harshad; Baum, Richard P; Odparlik, Andreas
2017-04-01
99m Tc-labeled MAA is commonly used for single photon emission computed tomography SPECT. In contrast, positron emission tomography/CT (PET/CT) delivers images with significantly higher resolution. The generator produced radionuclide 68 Ga is widely used for PET/CT imaging agents and 68 Ga-labeled MAA represents an attractive alternative to 99m Tc-labeled MAA. We report a simple and rapid NaCl based labeling procedure for the labeling of MAA with 68 Ga using a commercially available MAA labeling kit for 99m Tc. The procedure delivers 68 Ga-labeled MAA with a high specific activity and a high labeling efficiency (>99%). The synthesis does not require a final step of separation or the use of organic solvents. Copyright © 2017 Elsevier Ltd. All rights reserved.
A novel and fast method for proton range verification using a step wedge and 2D scintillator.
Shen, Jiajian; Allred, Bryce C; Robertson, Daniel G; Liu, Wei; Sio, Terence T; Remmes, Nicholas B; Keole, Sameer R; Bues, Martin
2017-09-01
To implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge. A homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge. The range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements. A novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible. © 2017 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Akiyama, Akira; Mutoh, Eiichiro; Kumagai, Hideo
2014-09-01
We have developed the stereo matching image processing by synthesized color and the corresponding area by the synthesized color for ranging the object and image recognition. The typical images from a pair of the stereo imagers may have some image disagreement each other due to the size change, missed place, appearance change and deformation of characteristic area. We constructed the synthesized color and corresponding color area with the same synthesized color to make the distinct stereo matching. We constructed the synthesized color and corresponding color area with the same synthesized color by the 3 steps. The first step is making binary edge image by differentiating the focused image from each imager and verifying that differentiated image has normal density of frequency distribution to find the threshold level of binary procedure. We used Daubechies wavelet transformation for the procedures of differentiating in this study. The second step is deriving the synthesized color by averaging color brightness between binary edge points with respect to horizontal direction and vertical direction alternatively. The averaging color procedure was done many times until the fluctuation of averaged color become negligible with respect to 256 levels in brightness. The third step is extracting area with same synthesized color by collecting the pixel of same synthesized color and grouping these pixel points by 4 directional connectivity relations. The matching areas for the stereo matching are determined by using synthesized color areas. The matching point is the center of gravity of each synthesized color area. The parallax between a pair of images is derived by the center of gravity of synthesized color area easily. The experiment of this stereo matching was done for the object of the soccer ball toy. From this experiment we showed that stereo matching by the synthesized color technique are simple and effective.
Stepwise detection of recombination breakpoints in sequence alignments.
Graham, Jinko; McNeney, Brad; Seillier-Moiseiwitsch, Françoise
2005-03-01
We propose a stepwise approach to identify recombination breakpoints in a sequence alignment. The approach can be applied to any recombination detection method that uses a permutation test and provides estimates of breakpoints. We illustrate the approach by analyses of a simulated dataset and alignments of real data from HIV-1 and human chromosome 7. The presented simulation results compare the statistical properties of one-step and two-step procedures. More breakpoints are found with a two-step procedure than with a single application of a given method, particularly for higher recombination rates. At higher recombination rates, the additional breakpoints were located at the cost of only a slight increase in the number of falsely declared breakpoints. However, a large proportion of breakpoints still go undetected. A makefile and C source code for phylogenetic profiling and the maximum chi2 method, tested with the gcc compiler on Linux and WindowsXP, are available at http://stat-db.stat.sfu.ca/stepwise/ jgraham@stat.sfu.ca.
Bras, Eduardo J S; Soares, Ruben R G; Azevedo, Ana M; Fernandes, Pedro; Arévalo-Rodríguez, Miguel; Chu, Virginia; Conde, João P; Aires-Barros, M Raquel
2017-09-15
Antibodies and other protein products such as interferons and cytokines are biopharmaceuticals of critical importance which, in order to be safely administered, have to be thoroughly purified in a cost effective and efficient manner. The use of aqueous two-phase extraction (ATPE) is a viable option for this purification, but these systems are difficult to model and optimization procedures require lengthy and expensive screening processes. Here, a methodology for the rapid screening of antibody extraction conditions using a microfluidic channel-based toolbox is presented. A first microfluidic structure allows a simple negative-pressure driven rapid screening of up to 8 extraction conditions simultaneously, using less than 20μL of each phase-forming solution per experiment, while a second microfluidic structure allows the integration of multi-step extraction protocols based on the results obtained with the first device. In this paper, this microfluidic toolbox was used to demonstrate the potential of LYTAG fusion proteins used as affinity tags to optimize the partitioning of antibodies in ATPE processes, where a maximum partition coefficient (K) of 9.2 in a PEG 3350/phosphate system was obtained for the antibody extraction in the presence of the LYTAG-Z dual ligand. This represents an increase of approx. 3.7 fold when compared with the same conditions without the affinity molecule (K=2.5). Overall, this miniaturized and versatile approach allowed the rapid optimization of molecule partition followed by a proof-of-concept demonstration of an integrated back extraction procedure, both of which are critical procedures towards obtaining high purity biopharmaceuticals using ATPE. Copyright © 2017 Elsevier B.V. All rights reserved.
Firing patterns in the adaptive exponential integrate-and-fire model.
Naud, Richard; Marcille, Nicolas; Clopath, Claudia; Gerstner, Wulfram
2008-11-01
For simulations of large spiking neuron networks, an accurate, simple and versatile single-neuron modeling framework is required. Here we explore the versatility of a simple two-equation model: the adaptive exponential integrate-and-fire neuron. We show that this model generates multiple firing patterns depending on the choice of parameter values, and present a phase diagram describing the transition from one firing type to another. We give an analytical criterion to distinguish between continuous adaption, initial bursting, regular bursting and two types of tonic spiking. Also, we report that the deterministic model is capable of producing irregular spiking when stimulated with constant current, indicating low-dimensional chaos. Lastly, the simple model is fitted to real experiments of cortical neurons under step current stimulation. The results provide support for the suitability of simple models such as the adaptive exponential integrate-and-fire neuron for large network simulations.
Dawidowicz, Andrzej L; Czapczyńska, Natalia B; Wianowska, Dorota
2013-02-01
Sea Sand Disruption Method (SSDM) is a simple and cheap sample-preparation procedure allowing the reduction of organic solvent consumption, exclusion of sample component degradation, improvement of extraction efficiency and selectivity, and elimination of additional sample clean-up and pre-concentration step before chromatographic analysis. This article deals with the possibility of SSDM application for the differentiation of essential-oils components occurring in the Scots pine (Pinus sylvestris L.) and cypress (Cupressus sempervirens L.) needles from Madrid (Spain), Laganas (Zakhyntos, Greece), Cala Morell (Menorca, Spain), Lublin (Poland), Helsinki (Finland), and Oradea (Romania). The SSDM results are related to the analogous - obtained applying two other sample preparation methods - steam distillation and Pressurized Liquid Extraction (PLE). The results presented established that the total amount and the composition of essential-oil components revealed by SSDM are equivalent or higher than those obtained by one of the most effective extraction technique, PLE. Moreover, SSDM seems to provide the most representative profile of all essential-oil components as no heat is applied. Thus, this environmentally friendly method is suggested to be used as the main extraction procedure for the differentiation of essential-oil components in conifers for scientific and industrial purposes. Copyright © 2013 Verlag Helvetica Chimica Acta AG, Zürich.
Picardi, Ernesto; Gallo, Angela; Galeano, Federica; Tomaselli, Sara; Pesole, Graziano
2012-01-01
RNA editing is a post-transcriptional process occurring in a wide range of organisms. In human brain, the A-to-I RNA editing, in which individual adenosine (A) bases in pre-mRNA are modified to yield inosine (I), is the most frequent event. Modulating gene expression, RNA editing is essential for cellular homeostasis. Indeed, its deregulation has been linked to several neurological and neurodegenerative diseases. To date, many RNA editing sites have been identified by next generation sequencing technologies employing massive transcriptome sequencing together with whole genome or exome sequencing. While genome and transcriptome reads are not always available for single individuals, RNA-Seq data are widespread through public databases and represent a relevant source of yet unexplored RNA editing sites. In this context, we propose a simple computational strategy to identify genomic positions enriched in novel hypothetical RNA editing events by means of a new two-steps mapping procedure requiring only RNA-Seq data and no a priori knowledge of RNA editing characteristics and genomic reads. We assessed the suitability of our procedure by confirming A-to-I candidates using conventional Sanger sequencing and performing RNA-Seq as well as whole exome sequencing of human spinal cord tissue from a single individual. PMID:22957051
FNA diagnostic value in patients with neck masses in two teaching hospitals in Iran.
Saatian, Minoo; Badie, Banafsheh Moradmand; Shahriari, Sogol; Fattahi, Fahimeh; Rasoolinejad, Mehrnaz
2011-01-01
The FNA (fine needle aspiration) procedure is simple, inexpensive, available and a safe method for the diagnosis of a neck mass. FNA has numerous advantages over open surgical biopsies as an initial diagnostic tool; therefore we decided to compare the accuracy of this method with open biopsy. This retrospective as well as descriptive study comparing preoperative FNA results with existing data in the Pathology Department in Bu-Ali and Amir Alam Hospitals. Our study included 100 patients with neck masses of which 22 were thyroid masses, 31 were salivary gland masses, and 47 were other masses. Age ranged from 3 years to 80 years with the mean age of 42.6 years. There were 59 men and 41 women. The Sensitivity was 72%, Specificity 87%, PPV 85%, NPV 75% and diagnostic Accuracy 79%. In this study we had also 26% false negative and 15% false positive. FNA is a valuable diagnostic tool in the management of neck masses; also it has been used for staging and planning of treatment for the wide and metastatic malignancy. This technique reduces the need for more invasive and costly procedures. According to the high sensitivity and high accuracy in this study, FNA can be used as the first step of diagnoses test in neck masses.
Metal- and additive-free photoinduced borylation of haloarenes.
Mfuh, Adelphe M; Schneider, Brett D; Cruces, Westley; Larionov, Oleg V
2017-03-01
Boronic acids and esters have critical roles in the areas of synthetic organic chemistry, molecular sensors, materials science, drug discovery, and catalysis. Many of the current applications of boronic acids and esters require materials with very low levels of transition metal contamination. Most of the current methods for the synthesis of boronic acids, however, require transition metal catalysts and ligands that must be removed via additional purification procedures. This protocol describes a simple, metal- and additive-free method of conversion of haloarenes directly to boronic acids and esters. This photoinduced borylation protocol does not require expensive and toxic metal catalysts or ligands, and it produces innocuous and easy-to-remove by-products. Furthermore, the reaction can be carried out on multigram scales in common-grade solvents without the need for reaction mixtures to be deoxygenated. The setup and purification steps are typically accomplished within 1-3 h. The reactions can be run overnight, and the protocol can be completed within 13-16 h. Two representative procedures that are described in this protocol provide details for preparation of a boronic acid (3-cyanopheylboronic acid) and a boronic ester (1,4-benzenediboronic acid bis(pinacol)ester). We also discuss additional details of the method that will be helpful in the application of the protocol to other haloarene substrates.
NASA Astrophysics Data System (ADS)
Lafitte, Pauline; Melis, Ward; Samaey, Giovanni
2017-07-01
We present a general, high-order, fully explicit relaxation scheme which can be applied to any system of nonlinear hyperbolic conservation laws in multiple dimensions. The scheme consists of two steps. In a first (relaxation) step, the nonlinear hyperbolic conservation law is approximated by a kinetic equation with stiff BGK source term. Then, this kinetic equation is integrated in time using a projective integration method. After taking a few small (inner) steps with a simple, explicit method (such as direct forward Euler) to damp out the stiff components of the solution, the time derivative is estimated and used in an (outer) Runge-Kutta method of arbitrary order. We show that, with an appropriate choice of inner step size, the time step restriction on the outer time step is similar to the CFL condition for the hyperbolic conservation law. Moreover, the number of inner time steps is also independent of the stiffness of the BGK source term. We discuss stability and consistency, and illustrate with numerical results (linear advection, Burgers' equation and the shallow water and Euler equations) in one and two spatial dimensions.
Yusakul, Gorawit; Nuntawong, Poomraphie; Sakamoto, Seiichi; Ratnatilaka Na Bhuket, Pahweenvaj; Kohno, Toshitaka; Kikkawa, Nao; Rojsitthisak, Pornchai; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi
2017-01-01
Due to the highly specific binding between an antibody and its target, superior analytical performances was obtained by immunoassays for phytochemical analysis over conventional chromatographic techniques. Here, we describe a simple method for producing a functional single-chain variable fragment (scFv) antibody against ganoderic acid A (GAA), a pharmacologically active metabolite from Ganoderma lingzhi. The Escherichia coli BL21(DE3) strain produced a large amount of anti-GAA scFv. However, in vitro refolding steps, which partially recovered the reactivity of the scFv, were required. Interestingly, the functional scFv was expressed as a soluble and active form in the cytoplasm of an engineered E. coli SHuffle ® strain. Purified anti-GAA scFv, which yielded 2.56 mg from 1 L of culture medium, was obtained from simple and inexpensive procedures for expression and purification. The anti-GAA scFv-based indirect competitive enzyme-linked immunosorbent assay (icELISA) exhibited high sensitivity (linearity: 0.078-1.25 µg/mL) with precision (CV: ≤6.20%) and reliability (recovery: 100.1-101.8%) for GAA determination. In summary, the approach described here is an inexpensive, simple, and efficient expression system that extends the application of anti-GAA scFv-based immunoassays. In addition, when in vitro refolding steps can be skipped, the cost and complexity of scFv antibody production can be minimized.
Two-port robotic hysterectomy: a novel approach.
Moawad, Gaby N; Tyan, Paul; Khalil, Elias D Abi
2018-03-24
The objective of the study was to demonstrate a novel technique for two-port robotic hysterectomy with a particular focus on the challenging portions of the procedure. The study is designed as a technical video, showing step-by-step a two-port robotic hysterectomy approach (Canadian Task Force classification level III). IRB approval was not required for this study. The benefits of minimally invasive surgery for gynecological pathology have been clearly documented in multiple studies. Patients had fewer medical and surgical complications postoperatively, better cosmesis and quality of life. Most gynecological surgeons require 3-5 ports for the standard gynecological procedure. Even though the minimally invasive multiport system provides an excellent safety profile, multiple incisions are associated with a greater risk for morbidity including infection, pain, and hernia. In the past decade, various new methods have emerged to minimize the number of ports used in gynecological surgery. The interventions employed were a two-port robotic hysterectomy, using a camera port plus one robotic arm, with a focus on salpingectomy and cuff closure. We describe a transvaginal and a transabdominal approach for salpingectomy and a novel method for cuff closure. The transvaginal and transabdominal techniques for salpingectomy for two-port robotic-assisted hysterectomy provide excellent tension and exposure for a safe procedure without the need for an extra port. We also describe a transvaginal technique to place the vaginal cuff on tension during closure. With the necessary set of skills on a carefully chosen patient, two-port robotic-assisted total laparoscopic hysterectomy is a feasible procedure.
One Step Quantum Key Distribution Based on EPR Entanglement
Li, Jian; Li, Na; Li, Lei-Lei; Wang, Tao
2016-01-01
A novel quantum key distribution protocol is presented, based on entanglement and dense coding and allowing asymptotically secure key distribution. Considering the storage time limit of quantum bits, a grouping quantum key distribution protocol is proposed, which overcomes the vulnerability of first protocol and improves the maneuverability. Moreover, a security analysis is given and a simple type of eavesdropper’s attack would introduce at least an error rate of 46.875%. Compared with the “Ping-pong” protocol involving two steps, the proposed protocol does not need to store the qubit and only involves one step. PMID:27357865
Student Opinions about the Seven-Step Procedure in Problem-Based Hospitality Management Education
ERIC Educational Resources Information Center
Zwaal, Wichard; Otting, Hans
2014-01-01
This study investigates how hospitality management students appreciate the role and application of the seven-step procedure in problem-based learning. A survey was developed containing sections about personal characteristics, recall of the seven steps, overall report marks, and 30 statements about the seven-step procedure. The survey was…
Arghavani-Beydokhti, Somayeh; Rajabi, Maryam; Asghari, Alireza
2017-07-01
A novel, efficient, rapid, simple, sensitive, selective, and environmentally friendly method termed magnetic dispersive micro solid-phase extraction combined with supramolecular solvent-based microextraction (Mdμ-SPE-SSME) followed by high-performance liquid chromatography (HPLC) with UV detection is introduced for the simultaneous microextraction of cholesterol-lowering drugs in complicated matrices. In the first microextraction procedure, using layered double hydroxide (LDH)-coated Fe 3 O 4 magnetic nanoparticles, an efficient sample cleanup is simply and rapidly provided without the need for time-consuming centrifugation and elution steps. In the first step, desorption of the target analytes is easily performed through dissolution of the LDH-coated magnetic nanoparticles containing the target analytes in an acidic solution. In the next step, an emulsification microextraction method based on a supramolecular solvent is used for excellent preconcentration, ultimately resulting in an appropriate determination of the target analytes in real samples. Under the optimal experimental conditions, the Mdμ-SPE-SSME-HPLC-UV detection procedure provides good linearity in the ranges of 1.0-1500 ng mL -1 , 1.5-2000 ng mL -1 , and 2.0-2000 ng mL -1 with coefficients of determination of 0.995 or less, low limits of detection (0.3, 0.5, and 0.5 ng mL -1 ), and good extraction repeatabilities (relative standard deviations below 7.8%, n = 5) in deionized water for rosuvastatin, atorvastatin, and gemfibrozil, respectively. Finally, the proposed method is successfully applied for the determination of the target analytes in complicated matrices. Graphical Abstract Mdμ-SPE-SSME procedure.
Mueller, Dirk; Klette, Ingo; Baum, Richard P; Gottschaldt, M; Schultz, Michael K; Breeman, Wouter A P
2012-08-15
A simple sodium chloride (NaCl) based (68)Ga eluate concentration and labeling method that enables rapid, high-efficiency labeling of DOTA conjugated peptides in high radiochemical purity is described. The method utilizes relatively few reagents and comprises minimal procedural steps. It is particularly well-suited for routine automated synthesis of clinical radiopharmaceuticals. For the (68)Ga generator eluate concentration step, commercially available cation-exchange cartridges and (68)Ga generators were used. The (68)Ga generator eluate was collected by use of a strong cation exchange cartridge. 98% of the total activity of (68)Ga was then eluted from the cation exchange cartridge with 0.5 mL of 5 M NaCl solution containing a small amount of 5.5 M HCl. After buffering with ammonium acetate, the eluate was used directly for radiolabeling of DOTATOC and DOTATATE. The (68)Ga-labeled peptides were obtained in higher radiochemical purity compared to other commonly used procedures, with radiochemical yields greater than 80%. The presence of (68)Ge could not be detected in the final product. The new method obviates the need for organic solvents, which eliminates the required quality control of the final product by gas chromatography, thereby reducing postsynthesis analytical effort significantly. The (68)Ga-labeled products were used directly, with no subsequent purification steps, such as solid-phase extraction. The NaCl method was further evaluated using an automated fluid handling system and it routinely facilitates radiochemical yields in excess of 65% in less than 15 min, with radiochemical purity consistently greater than 99% for the preparation of (68)Ga-DOTATOC.
On the Least-Squares Fitting of Correlated Data: a Priorivs a PosterioriWeighting
NASA Astrophysics Data System (ADS)
Tellinghuisen, Joel
1996-10-01
One of the methods in common use for analyzing large data sets is a two-step procedure, in which subsets of the full data are first least-squares fitted to a preliminary set of parameters, and the latter are subsequently merged to yield the final parameters. The second step of this procedure is properly a correlated least-squares fit and requires the variance-covariance matrices from the first step to construct the weight matrix for the merge. There is, however, an ambiguity concerning the manner in which the first-step variance-covariance matrices are assessed, which leads to different statistical properties for the quantities determined in the merge. The issue is one ofa priorivsa posterioriassessment of weights, which is an application of what was originally calledinternalvsexternal consistencyby Birge [Phys. Rev.40,207-227 (1932)] and Deming ("Statistical Adjustment of Data." Dover, New York, 1964). In the present work the simplest case of a merge fit-that of an average as obtained from a global fit vs a two-step fit of partitioned data-is used to illustrate that only in the case of a priori weighting do the results have the usually expected and desired statistical properties: normal distributions for residuals,tdistributions for parameters assessed a posteriori, and χ2distributions for variances.
ERIC Educational Resources Information Center
Kurt, Onur
2011-01-01
The present study was designed to compare the effectiveness and efficiency of two discrete trial teaching procedures for teaching receptive language skills to children with autism. While verbal instructions were delivered alone during the first procedure, all verbal instructions were combined with simple gestures and/or signs during the second…
Why McNemar's Procedure Needs to Be Included in the Business Statistics Curriculum
ERIC Educational Resources Information Center
Berenson, Mark L.; Koppel, Nicole B.
2005-01-01
In business research situations it is often of interest to examine the differences in the responses in repeated measurements of the same subjects or from among matched or paired subjects. A simple and useful procedure for comparing differences between proportions in two related samples was devised by McNemar (1947) nearly 60 years ago. Although…
Single-step colony assay for screening antibody libraries.
Kato, Mieko; Hanyu, Yoshiro
2017-08-10
We describe a method, single-step colony assay, for simple and rapid screening of single-chain Fv fragment (scFv) libraries. Colonies of Escherichia coli expressing the scFv library are formed on a hydrophilic filter that is positioned in contact with a membrane coated with an antigen. scFv expression is triggered upon treatment of colonies with an induction reagent, following which scFvs are secreted from the cells and diffused to the antigen-coated membrane. scFvs that exhibit binding affinity for the antigen are captured by the membrane-immobilized antigen. Lastly, detection of scFv binding of the antigen on the membrane allows identification of the clones on the filter that express antigen-specific scFvs. We tested this methodology by using an anti-rabbit IgG scFv, scFv(A10B), and a rat immune scFv library. Experiments conducted using scFv(A10B) revealed that this method improves scFv expression during the colony assay. By using our method to screen an immune library of 3×10 3 scFv clones, we established several clones exhibiting affinity for the antigen. Moreover, we tested 7 other antigens, including peptides, and successfully identified positive clones. We believe that this simple procedure and controlled scFv expression of the single-step colony assay could make the antibody screening both rapid and reliable and lead to successful isolation of positive clones from antibody libraries. Copyright © 2017 Elsevier B.V. All rights reserved.
Jeong, Chanyoung; Choi, Chang-Hwan
2012-02-01
Conventional electrochemical anodizing processes of metals such as aluminum typically produce planar and homogeneous nanopore structures. If hydrophobically treated, such 2D planar and interconnected pore structures typically result in lower contact angle and larger contact angle hysteresis than 3D disconnected pillar structures and, hence, exhibit inferior superhydrophobic efficiency. In this study, we demonstrate for the first time that the anodizing parameters can be engineered to design novel pillar-on-pore (POP) hybrid nanostructures directly in a simple one-step fabrication process so that superior surface superhydrophobicity can also be realized effectively from the electrochemical anodization process. On the basis of the characteristic of forming a self-ordered porous morphology in a hexagonal array, the modulation of anodizing voltage and duration enabled the formulation of the hybrid-type nanostructures having controlled pillar morphology on top of a porous layer in both mild and hard anodization modes. The hybrid nanostructures of the anodized metal oxide layer initially enhanced the surface hydrophilicity significantly (i.e., superhydrophilic). However, after a hydrophobic monolayer coating, such hybrid nanostructures then showed superior superhydrophobic nonwetting properties not attainable by the plain nanoporous surfaces produced by conventional anodization conditions. The well-regulated anodization process suggests that electrochemical anodizing can expand its usefulness and efficacy to render various metallic substrates with great superhydrophilicity or -hydrophobicity by directly realizing pillar-like structures on top of a self-ordered nanoporous array through a simple one-step fabrication procedure.
Computation of Acoustic Waves Through Sliding-Zone Interfaces Using an Euler/Navier-Stokes Code
NASA Technical Reports Server (NTRS)
Rumsey, Christopher L.
1996-01-01
The effect of a patched sliding-zone interface on the transmission of acoustic waves is examined for two- and three-dimensional model problems. A simple but general interpolation scheme at the patched boundary passes acoustic waves without distortion, provided that a sufficiently small time step is taken. A guideline is provided for the maximum permissible time step or zone speed that gives an acceptable error introduced by the sliding-zone interface.
NASA Astrophysics Data System (ADS)
Meneses-Fabian, Cruz
2016-12-01
This paper presents a non-iterative, fast, and simple algorithm for phase retrieval, in phase-shifting interferometry of three unknown and unequal phase-steps, based on the geometric concept of the volume enclosed by a surface. This approach can be divided in three stages; first the background is eliminated by the subtraction of two interferograms, for obtaining a secondary pattern; second, a surface is built by the product of two secondary patterns and the volume enclosed by this surface is computed; and third, the ratio between two enclosed volumes is approximated to a constant that depends on the phase-steps, with which a system of equations is established, and its solution allows the measurement of the phase-steps to be obtained. Additional advantages of this approach are its immunity to noise, and its capacity to support high spatial variations in the illumination. This approach is theoretically described and is numerically and experimentally verified.
CCD image sensor induced error in PIV applications
NASA Astrophysics Data System (ADS)
Legrand, M.; Nogueira, J.; Vargas, A. A.; Ventas, R.; Rodríguez-Hidalgo, M. C.
2014-06-01
The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (˜0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.
Conventional and two step sintering of PZT-PCN ceramics
NASA Astrophysics Data System (ADS)
Keshavarzi, Mostafa; Rahmani, Hooman; Nemati, Ali; Hashemi, Mahdieh
2018-02-01
In this study, PZT-PCN ceramic was made via sol-gel seeding method and effects of conventional sintering (CS) as well as two-step sintering (TSS) were investigated on microstructure, phase formation, density, dielectric and piezoelectric properties. First, high quality powder was achieved by seeding method in which the mixture of Co3O4 and Nb2O5 powder was added to the prepared PZT sol to form PZT-PCN gel. After drying and calcination, pyrochlore free PZT-PCN powder was synthesized. Second, CS and TSS were applied to achieve dense ceramic. The optimum temperature used for 2 h of conventional sintering was obtained at 1150 °C; finally, undesired ZrO2 phase formed in CS procedure was removed successfully with TSS procedure and dielectric and piezoelectric properties were improved compared to the CS procedure. The best electrical properties obtained for the sample sintered by TSS in the initial temperature of T 1 = 1200 °C and secondary temperature of T 2 = 1000 °C for 12 h.
Size-tailored synthesis of silver quasi-nanospheres by kinetically controlled seeded growth.
Liu, Xiaxia; Yin, Yadong; Gao, Chuanbo
2013-08-20
This paper describes a simple and convenient procedure to synthesize monodisperse silver (Ag) quasi-nanospheres with size tunable in a range of 19-140 nm through a one-step seeded growth strategy. Acetonitrile was employed as a coordinating ligand of a Ag(I) salt in order to achieve a low concentration of elemental Ag after reduction and thus suppression of new nucleation events. Since the addition of the seeds significantly accelerates the reduction reaction of Ag(I) by ascorbic acid, the reaction kinetics was further delicately balanced by tuning the reaction temperature, which proved to be critical in producing Ag quasi-nanospheres with uniform size and shape. This synthesis is highly scalable, so that it provides a simple yet very robust process for producing Ag quasi-nanospheres for many biological, analytical, and catalytic applications which often demand samples in large quantity and widely tunable particle sizes.
NASA Astrophysics Data System (ADS)
Bournia-Petrou, Ethel A.
The main goal of this investigation was to study how student rank in class, student gender and skill sequence affect high school students' performance on the lab skills involved in a laboratory-based inquiry task in physics. The focus of the investigation was the effect of skill sequence as determined by the particular task. The skills considered were: Hypothesis, Procedure, Planning, Data, Graph, Calculations and Conclusion. Three physics lab tasks based on the simple pendulum concept were administered to 282 Regents physics high school students. The reliability of the designed tasks was high. Student performance was evaluated on individual student written responses and a scoring rubric. The tasks had high discrimination power and were of moderate difficulty (65%). It was found that, student performance was weak on Conclusion (42%), Hypothesis (48%), and Procedure (51%), where the numbers in parentheses represent the mean as a percentage of the maximum possible score. Student performance was strong on Calculations (91%), Data (82%), Graph (74%) and Plan (68%). Out of all seven skills, Procedure had the strongest correlation (.73) with the overall task performance. Correlation analysis revealed some strong relationships among the seven skills which were grouped in two distinct clusters: Hypothesis, Procedure and Plan belong to one, and Data, Graph, Calculations, and Conclusion belong to the other. This distinction may indicate different mental processes at play within each skill cluster. The effect of student rank was not statistically significant according to the MANOVA results due to the large variation of rank levels among the participating schools. The effect of gender was significant on the entire test because of performance differences on Calculations and Graph, where male students performed better than female students. Skill sequence had a significant effect on the skills of Procedure, Plan, Data and Conclusion. Students are rather weak in proposing a sensible, detailed procedure for the inquiry task which involves the "novel" concept. However they perform better on Procedure and Plan, if the "novel" task is not preceded by another, which explicitly offers step-by-step procedure instructions. It was concluded that the format of detailed, structured instructions often adopted by many commercial and school-developed lab books and conventional lab practices, fails to prepare students to propose a successful, detailed procedure when faced with a slightly "novel", lab-based inquiry task. Student performance on Data collection was higher in the tasks that involved the more familiar experimental arrangement than in the tasks using the slightly "novel" equipment. Student performance on Conclusion was better in tasks where they had to collect the Data themselves than in tasks, where all relevant Data information was given to them.
Wright, Michael T; Parker, David R; Amrhein, Christopher
2003-10-15
Sequential extraction procedures (SEPs) have been widely used to characterize the mobility, bioavailibility, and potential toxicity of trace elements in soils and sediments. Although oft-criticized, these methods may perform best with redox-labile elements (As, Hg, Se) for which more discrete biogeochemical phases may arise from variations in oxidation number. We critically evaluated two published SEPs for Se for their specificity and precision by applying them to four discrete components in an inert silica matrix: soluble Se(VI) (selenate), Se(IV) (selenite) adsorbed onto goethite, elemental Se, and a metal selenide (FeSe; achavalite). These were extracted both individually and in a mixed model sediment. The more selective of the two procedures was modified to further improve its selectivity (SEP 2M). Both SEP 1 and SEP 2M quantitatively recovered soluble selenate but yielded incomplete recoveries of adsorbed selenite (64% and 81%, respectively). SEP 1 utilizes 0.1 M K2S2O8 to target "organically associated" Se, but this extractant also solubilized most of the elemental (64%) and iron selenide (91%) components of the model sediment. In SEP 2M, the Na2SO3 used in step III is effective in extracting elemental Se but also extracted 17% of the Se from the iron selenide, such that the elemental fraction would be overestimated should both forms coexist. Application of SEP 2M to eight wetland sediments further suggested that the Na2SO3 in step III extracts some organically associated Se, so a NaOH extraction was inserted beforehand to yield a further modification, SEP 2OH. Results using this five-step procedure suggested that the four-step SEP 2M could overestimate elemental Se by as much as 43% due to solubilization of organic Se. Although still imperfect in its selectivity, SEP 20H may be the most suitable procedure for routine, accurate fractionation of Se in soils and sediments. However, the strong oxidant (NaOCl) used in the final step cannot distinguish between refractory organic forms of Se and pyritic Se that might form under sulfur-reducing conditions.
NASA Astrophysics Data System (ADS)
Nguyen, L. T.; Modrak, R. T.; Saenger, E. H.; Tromp, J.
2017-12-01
Reverse-time migration (RTM) can reconstruct reflectors and scatterers by cross-correlating the source wavefield and the receiver wavefield given a known velocity model of the background. In nondestructive testing, however, the engineered structure under inspection is often composed of layers of various materials and the background material has been degraded non-uniformly because of environmental or operational effects. On the other hand, ultrasonic waveform tomography based on the principles of full-waveform inversion (FWI) has succeeded in detecting anomalous features in engineered structures. But the building of the wave velocity model of the comprehensive small-size and high-contrast defect(s) is difficult because it requires computationally expensive high-frequency numerical wave simulations and an accurate understanding of large-scale background variations of the engineered structure.To reduce computational cost and improve detection of small defects, a useful approach is to divide the waveform tomography procedure into two steps: first, a low-frequency model-building step aimed at recovering background structure using FWI, and second, a high-frequency imaging step targeting defects using RTM. Through synthetic test cases, we show that the two-step procedure appears more promising in most cases than a single-step inversion. In particular, we find that the new workflow succeeds in the challenging scenario where the defect lies along preexisting layer interface in a composite bridge deck and in related experiments involving noisy data or inaccurate source parameters. The results reveal the potential of the new wavefield imaging method and encourage further developments in data processing, enhancing computation power, and optimizing the imaging workflow itself so that the procedure can efficiently be applied to geometrically complex 3D solids and waveguides. Lastly, owing to the scale invariance of the elastic wave equation, this imaging procedure can be transferred to applications in regional scales as well.
ERIC Educational Resources Information Center
Chansirisira, Pacharawit
2012-01-01
The research aimed to investigate the core competency elements and the factors affecting the performance efficiency of the civil service teachers in the northeastern region, Thailand. The research procedure consisted of two steps. In the first step, the data were collected using a questionnaire with the reliability (Cronbach's Alpha) of 0.90. The…
Markov Chains For Testing Redundant Software
NASA Technical Reports Server (NTRS)
White, Allan L.; Sjogren, Jon A.
1990-01-01
Preliminary design developed for validation experiment that addresses problems unique to assuring extremely high quality of multiple-version programs in process-control software. Approach takes into account inertia of controlled system in sense it takes more than one failure of control program to cause controlled system to fail. Verification procedure consists of two steps: experimentation (numerical simulation) and computation, with Markov model for each step.
Richardson, James K.; Eckner, James T.; Allet, Lara; Kim, Hogene; Ashton-Miller, James
2016-01-01
Objective To identify relationships between complex and simple clinical measures of reaction time (RTclin), and indicators of balance in older subjects with and without diabetic peripheral neuropathy (DPN). Design Prospective cohort design. Complex RTclin Accuracy, Simple RTclin Latency, and their ratio were determined using a novel device in 42 subjects (age = 69.1 ± 8.3 yrs), 26 with DPN and 16 without. Dependent variables included unipedal stance time (UST), step width variability and range on an uneven surface, and major fall-related injury over 12 months. Results In the DPN subjects the ratio of Complex RTclin Accuracy:Simple RTclin Latency was strongly associated with longer UST (r/p = .653/.004), and decreased step width variability and range (r/p = −.696/.001 and −.782/<.001, respectively) on an uneven surface. Additionally, the two DPN subjects sustaining major injuries had lower Complex RTclin Accuracy:Simple: RTclin Latency than those without. Conclusions The ratio of Complex RTclin Accuracy:Simple RTclin Latency is a potent predictor of UST and frontal plane gait variability in response to perturbations, and may predict major fall injury in older subjects with DPN. These short latency neurocognitive measures may compensate for lower limb neuromuscular impairments, and provide a more comprehensive understanding of balance and fall risk. PMID:27552354
Analysis of Cereal Starches by High Performance Size Exclusion Chromatography
USDA-ARS?s Scientific Manuscript database
Starch has unique physicochemical characteristics among carbohydrates. Most starch granules are a mixture of two sugar polymers: a highly branched polysaccharide named amylopectin, and a basically linear polysaccharide named amylose. The objective of this study was to develop a simple, one-step and ...
Regularized two-step brain activity reconstruction from spatiotemporal EEG data
NASA Astrophysics Data System (ADS)
Alecu, Teodor I.; Voloshynovskiy, Sviatoslav; Pun, Thierry
2004-10-01
We are aiming at using EEG source localization in the framework of a Brain Computer Interface project. We propose here a new reconstruction procedure, targeting source (or equivalently mental task) differentiation. EEG data can be thought of as a collection of time continuous streams from sparse locations. The measured electric potential on one electrode is the result of the superposition of synchronized synaptic activity from sources in all the brain volume. Consequently, the EEG inverse problem is a highly underdetermined (and ill-posed) problem. Moreover, each source contribution is linear with respect to its amplitude but non-linear with respect to its localization and orientation. In order to overcome these drawbacks we propose a novel two-step inversion procedure. The solution is based on a double scale division of the solution space. The first step uses a coarse discretization and has the sole purpose of globally identifying the active regions, via a sparse approximation algorithm. The second step is applied only on the retained regions and makes use of a fine discretization of the space, aiming at detailing the brain activity. The local configuration of sources is recovered using an iterative stochastic estimator with adaptive joint minimum energy and directional consistency constraints.
NASA Technical Reports Server (NTRS)
Walker, H. F.
1976-01-01
Likelihood equations determined by the two types of samples which are necessary conditions for a maximum-likelihood estimate are considered. These equations, suggest certain successive-approximations iterative procedures for obtaining maximum-likelihood estimates. These are generalized steepest ascent (deflected gradient) procedures. It is shown that, with probability 1 as N sub 0 approaches infinity (regardless of the relative sizes of N sub 0 and N sub 1, i=1,...,m), these procedures converge locally to the strongly consistent maximum-likelihood estimates whenever the step size is between 0 and 2. Furthermore, the value of the step size which yields optimal local convergence rates is bounded from below by a number which always lies between 1 and 2.
Karimi, Shima; Talebpour, Zahra; Adib, Noushin
2016-06-14
A poly acrylate-ethylene glycol (PA-EG) thin film is introduced for the first time as a novel polar sorbent for sorptive extraction method coupled directly to solid-state spectrofluorimetry without the necessity of a desorption step. The structure, polarity, fluorescence property and extraction performance of the developed thin film were investigated systematically. Carvedilol was used as the model analyte to evaluate the proposed method. The entire procedure involved one-step extraction of carvedilol from plasma using PA-EG thin film sorptive phase without protein precipitation. Extraction variables were studied in order to establish the best experimental conditions. Optimum extraction conditions were the followings: stirring speed of 1000 rpm, pH of 6.8, extraction temperature of 60 °C, and extraction time of 60 min. Under optimal conditions, extraction of carvedilol was carried out in spiked human plasma; and the linear range of calibration curve was 15-300 ng mL(-1) with regression coefficient of 0.998. Limit of detection (LOD) for the method was 4.5 ng mL(-1). The intra- and inter-day accuracy and precision of the proposed method were evaluated in plasma sample spiked with three concentration levels of carvedilol; yielding a recovery of 91-112% and relative standard deviation of less than 8%, respectively. The established procedure was successfully applied for quantification of carvedilol in plasma sample of a volunteer patient. The developed PA-EG thin film sorptive phase followed by solid-state spectrofluorimetric method provides a simple, rapid and sensitive approach for the analysis of carvedilol in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Daiwon; Jampani, Prashanth H.; Jayakody, J. R. P.
Chloroamide precursors generated via a simple two-step ammonolysis reaction of transition metal chloride in the liquid phase at room temperature were heat treated in ammonia at moderate temperature to yield nano-sized VN crystallites. Grain growth inhibited by lowering the synthesis temperature (≈400°C) yielded agglomerated powders of spherical crystallites of cubic phase of VN with particle sizes as small as 6nm in diameter. X-ray diffraction, FTIR, mass spectroscopy (MS), and nuclear magnetic resonance (NMR) spectroscopy assessed the ammonolysis and nitridation reaction of the VCl 4-NH 3 system. X-ray Rietveld refinement, the BET technique and high-resolution transmission microscopy (HRTEM), energy dispersive x-raymore » (EDX) and thermogravimetric analysis (TGA) helped assess the crystallographic and microstructural nature of the VN nanocrystals. The surface chemistry and redox reaction leading to the gravimetric pseudo-capacitance value of (≈855 F/g) measured for the VN nanocrystals was determined and validated using FTIR, XPS and cyclic voltammetry analyses.« less
Pylorus preserving loop duodeno-enterostomy with sleeve gastrectomy - preliminary results
2014-01-01
Background Bariatric operations mostly combine a restrictive gastric component with a rerouting of the intestinal passage. The pylorus can thereby be alternatively preserved or excluded. With the aim of performing a “pylorus-preserving gastric bypass”, we present early results of a proximal postpyloric loop duodeno-jejunostomy associated with a sleeve gastrectomy (LSG) compared to results of a parallel, but distal LSG with a loop duodeno-ileostomy as a two-step procedure. Methods 16 patients underwent either a two-step LSG with a distal loop duodeno-ileostomy (DIOS) as revisional bariatric surgery or a combined single step operation with a proximal duodeno-jejunostomy (DJOS). Total small intestinal length was determined to account for inter-individual differences. Results Mean operative time for the second-step of the DIOS operation was 121 min and 147 min for the combined DJOS operation. The overall intestinal length was 750.8 cm (range 600-900 cm) with a bypassed limb length of 235.7 cm in DJOS patients. The mean length of the common channel in DIOS patients measured 245.6 cm. Overall excess weight loss (%EWL) of the two-step DIOS procedure came to 38.31% and 49.60%, DJOS patients experienced an %EWL of 19.75% and 46.53% at 1 and 6 months, resp. No complication related to the duodeno-enterostomy occurred. Conclusions Loop duodeno-enterosomies with sleeve gastrectomy can be safely performed and may open new alternatives in bariatric surgery with the possibility for inter-individual adaptation. PMID:24725654
Hydrophobic duck feathers and their simulation on textile substrates for water repellent treatment.
Liu, Yuyang; Chen, Xianqiong; Xin, J H
2008-12-01
Inspired by the non-wetting phenomena of duck feathers, the water repellent property of duck feathers was studied at the nanoscale. The microstructures of the duck feather were investigated by a scanning electron microscope (SEM) imaging method through a step-by-step magnifying procedure. The SEM results show that duck feathers have a multi-scale structure and that this multi-scale structure as well as the preening oil are responsible for their super hydrophobic behavior. The microstructures of the duck feather were simulated on textile substrates using the biopolymer chitosan as building blocks through a novel surface solution precipitation (SSP) method, and then the textile substrates were further modified with a silicone compound to achieve low surface energy. The resultant textiles exhibit super water repellent properties, thus providing a simple bionic way to create super hydrophobic surfaces on soft substrates using flexible material as building blocks.
Yun, Eun Kyoung; Chun, Kee Moon
2008-01-01
Telemedicine generally refers to the use of communications and information technologies for the delivery of health care. owever, telemedicine is not merely a simple combination of health care and technology. The researchers propose a systematic approach for assessing needs of telemedicine customers, called critical-to-quality (CTQ) in Six Sigma, with a purpose of continuous quality improvement. The combination approach using DFSS (Design for Six Sigma) and SERVQUAL (Service Quality Framework) was applied to define the critical quality attributes of telemedicine service management and to match them with the current telemedicine process. With a step-by-step procedure, telemedicine service process was reviewed and all the important CTQ candidates identified via a case study. The findings suggest that nurses need further understanding and research methods that will improve and manage the quality of health care service in various medical fields.
Jeong, Jong Seok; Mkhoyan, K Andre
2016-06-01
Acquiring an atomic-resolution compositional map of crystalline specimens has become routine practice, thus opening possibilities for extracting subatomic information from such maps. A key challenge for achieving subatomic precision is the improvement of signal-to-noise ratio (SNR) of compositional maps. Here, we report a simple and reliable solution for achieving high-SNR energy-dispersive X-ray (EDX) spectroscopy spectrum images for individual atomic columns. The method is based on standard cross-correlation aided by averaging of single-column EDX maps with modifications in the reference image. It produces EDX maps with minimal specimen drift, beam drift, and scan distortions. Step-by-step procedures to determine a self-consistent reference map with a discussion on the reliability, stability, and limitations of the method are presented here.
Passive hand movements disrupt adults' counting strategies.
Imbo, Ineke; Vandierendonck, André; Fias, Wim
2011-01-01
In the present study, we experimentally tested the role of hand motor circuits in simple-arithmetic strategies. Educated adults solved simple additions (e.g., 8 + 3) or simple subtractions (e.g., 11 - 3) while they were required to retrieve the answer from long-term memory (e.g., knowing that 8 + 3 = 11), to transform the problem by making an intermediate step (e.g., 8 + 3 = 8 + 2 + 1 = 10 + 1 = 11) or to count one-by-one (e.g., 8 + 3 = 8…9…10…11). During the process of solving the arithmetic problems, the experimenter did or did not move the participants' hand on a four-point matrix. The results show that passive hand movements disrupted the counting strategy while leaving the other strategies unaffected. This pattern of results is in agreement with a procedural account, showing that the involvement of hand motor circuits in adults' mathematical abilities is reminiscent of finger counting during childhood.
Simple and rapid quantification of brominated vegetable oil in commercial soft drinks by LC–MS
Chitranshi, Priyanka; da Costa, Gonçalo Gamboa
2016-01-01
We report here a simple and rapid method for the quantification of brominated vegetable oil (BVO) in soft drinks based upon liquid chromatography–electrospray ionization mass spectrometry. Unlike previously reported methods, this novel method does not require hydrolysis, extraction or derivatization steps, but rather a simple “dilute and shoot” sample preparation. The quantification is conducted by mass spectrometry in selected ion recording mode and a single point standard addition procedure. The method was validated in the range of 5–25 μg/mL BVO, encompassing the legal limit of 15 μg/mL established by the US FDA for fruit-flavored beverages in the US market. The method was characterized by excellent intra- and inter-assay accuracy (97.3–103.4%) and very low imprecision [0.5–3.6% (RSD)]. The direct nature of the quantification, simplicity, and excellent statistical performance of this methodology constitute clear advantages in relation to previously published methods for the analysis of BVO in soft drinks. PMID:27451219
Interrelations between random walks on diagrams (graphs) with and without cycles.
Hill, T L
1988-05-01
Three topics are discussed. A discrete-state, continuous-time random walk with one or more absorption states can be studied by a presumably new method: some mean properties, including the mean time to absorption, can be found from a modified diagram (graph) in which each absorption state is replaced by a one-way cycle back to the starting state. The second problem is a random walk on a diagram (graph) with cycles. The walk terminates on completion of the first cycle. This walk can be replaced by an equivalent walk on a modified diagram with absorption. This absorption diagram can in turn be replaced by another modified diagram with one-way cycles back to the starting state, just as in the first problem. The third problem, important in biophysics, relates to a long-time continuous walk on a diagram with cycles. This diagram can be transformed (in two steps) to a modified, more-detailed, diagram with one-way cycles only. Thus, the one-way cycle fluxes of the original diagram can be found from the state probabilities of the modified diagram. These probabilities can themselves be obtained by simple matrix inversion (the probabilities are determined by linear algebraic steady-state equations). Thus, a simple method is now available to find one-way cycle fluxes exactly (previously Monte Carlo simulation was required to find these fluxes, with attendant fluctuations, for diagrams of any complexity). An incidental benefit of the above procedure is that it provides a simple proof of the one-way cycle flux relation Jn +/- = IIn +/- sigma n/sigma, where n is any cycle of the original diagram.
Chen, Chi-Kan
2017-07-26
The identification of genetic regulatory networks (GRNs) provides insights into complex cellular processes. A class of recurrent neural networks (RNNs) captures the dynamics of GRN. Algorithms combining the RNN and machine learning schemes were proposed to reconstruct small-scale GRNs using gene expression time series. We present new GRN reconstruction methods with neural networks. The RNN is extended to a class of recurrent multilayer perceptrons (RMLPs) with latent nodes. Our methods contain two steps: the edge rank assignment step and the network construction step. The former assigns ranks to all possible edges by a recursive procedure based on the estimated weights of wires of RNN/RMLP (RE RNN /RE RMLP ), and the latter constructs a network consisting of top-ranked edges under which the optimized RNN simulates the gene expression time series. The particle swarm optimization (PSO) is applied to optimize the parameters of RNNs and RMLPs in a two-step algorithm. The proposed RE RNN -RNN and RE RMLP -RNN algorithms are tested on synthetic and experimental gene expression time series of small GRNs of about 10 genes. The experimental time series are from the studies of yeast cell cycle regulated genes and E. coli DNA repair genes. The unstable estimation of RNN using experimental time series having limited data points can lead to fairly arbitrary predicted GRNs. Our methods incorporate RNN and RMLP into a two-step structure learning procedure. Results show that the RE RMLP using the RMLP with a suitable number of latent nodes to reduce the parameter dimension often result in more accurate edge ranks than the RE RNN using the regularized RNN on short simulated time series. Combining by a weighted majority voting rule the networks derived by the RE RMLP -RNN using different numbers of latent nodes in step one to infer the GRN, the method performs consistently and outperforms published algorithms for GRN reconstruction on most benchmark time series. The framework of two-step algorithms can potentially incorporate with different nonlinear differential equation models to reconstruct the GRN.
Reconnaissance On Chi-Square Test Procedure For Determining Two Species Association
NASA Astrophysics Data System (ADS)
Marisa, Hanifa
2008-01-01
Determining the assosiation of two species by using chi-square test has been published. Utility of this procedure to plants species at certain location, shows that the procedure could not find "ecologically" association. Tens sampling units have been made to record some weeds species in Indralaya, South Sumatera. Chi square test; Xt2 = N[|(ad)-(bc)|-(N/2)]2/mnrs (Eq:1) on two species (Cleome sp and Eleusine indica) of the weeds shows positive assosiation; while ecologically in nature, there is no relationship between them. Some alternatives are proposed to this problem; simplified chi-square test steps, make further study to find out ecologically association, or at last, ignore it.
Facilitating Proportional Reasoning through Worked Examples: Two Classroom-Based Experiments
ERIC Educational Resources Information Center
Bentley, Brendan; Yates, Gregory C. R.
2017-01-01
Within mathematics teaching, ways to help students resolve proportional reasoning problems remains a topical issue. This study sought to investigate how a simple innovative procedure could be introduced to enhance skill acquisition. In two classroom-based experiments, 12-year-old students were asked to solve proportional reasoning mathematics…
Toledo-Núñez, Citlali; Vera-Robles, L Iraís; Arroyo-Maya, Izlia J; Hernández-Arana, Andrés
2016-09-15
A frequent outcome in differential scanning calorimetry (DSC) experiments carried out with large proteins is the irreversibility of the observed endothermic effects. In these cases, DSC profiles are analyzed according to methods developed for temperature-induced denaturation transitions occurring under kinetic control. In the one-step irreversible model (native → denatured) the characteristics of the observed single-peaked endotherm depend on the denaturation enthalpy and the temperature dependence of the reaction rate constant, k. Several procedures have been devised to obtain the parameters that determine the variation of k with temperature. Here, we have elaborated on one of these procedures in order to analyze more complex DSC profiles. Synthetic data for a heat capacity curve were generated according to a model with two sequential reactions; the temperature dependence of each of the two rate constants involved was determined, according to the Eyring's equation, by two fixed parameters. It was then shown that our deconvolution procedure, by making use of heat capacity data alone, permits to extract the parameter values that were initially used. Finally, experimental DSC traces showing two and three maxima were analyzed and reproduced with relative success according to two- and four-step sequential models. Copyright © 2016 Elsevier Inc. All rights reserved.
Performance of the Seven-Step Procedure in Problem-Based Hospitality Management Education
ERIC Educational Resources Information Center
Zwaal, Wichard; Otting, Hans
2016-01-01
The study focuses on the seven-step procedure (SSP) in problem-based learning (PBL). The way students apply the seven-step procedure will help us understand how students work in a problem-based learning curriculum. So far, little is known about how students rate the performance and importance of the different steps, the amount of time they spend…
Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru
2013-11-01
The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (p<0.001), but the distance of that was so small (mean, 0.47 mm) that it did not cause any problem clinically. Although further improvement might be needed, such as screw specification, the closed reduction and internal fixation method has many advantages: short operative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.
Linezolid in late-chronic prosthetic joint infection caused by gram-positive bacteria.
Cobo, Javier; Lora-Tamayo, Jaime; Euba, Gorane; Jover-Sáenz, Alfredo; Palomino, Julián; del Toro, Ma Dolores; Rodríguez-Pardo, Dolors; Riera, Melchor; Ariza, Javier
2013-05-01
Linezolid may be an interesting alternative for prosthetic joint infection (PJI) due to its bioavailability and its antimicrobial spectrum. However, experience in this setting is scarce. The aim of the study was to assess linezolid's clinical and microbiological efficacy, and also its tolerance. This was a prospective, multicenter, open-label, non-comparative study of 25 patients with late-chronic PJI caused by Gram-positive bacteria managed with a two-step exchange procedure plus 6 weeks of linezolid. Twenty-two (88%) patients tolerated linezolid without major adverse effects, although a global decrease in the platelet count was observed. Three patients were withdrawn because of major toxicity, which reversed after linezolid stoppage. Among patients who completed treatment, 19 (86%) demonstrated clinical and microbiological cure. Two patients presented with clinical and microbiological failure, and one showed clinical cure and microbiological failure. In conclusion, linezolid showed good results in chronic PJI managed with a two-step exchange procedure. Tolerance seems acceptable, though close surveillance is required. Copyright © 2013 Elsevier Inc. All rights reserved.
Step by Step: Biology Undergraduates’ Problem-Solving Procedures during Multiple-Choice Assessment
Prevost, Luanna B.; Lemons, Paula P.
2016-01-01
This study uses the theoretical framework of domain-specific problem solving to explore the procedures students use to solve multiple-choice problems about biology concepts. We designed several multiple-choice problems and administered them on four exams. We trained students to produce written descriptions of how they solved the problem, and this allowed us to systematically investigate their problem-solving procedures. We identified a range of procedures and organized them as domain general, domain specific, or hybrid. We also identified domain-general and domain-specific errors made by students during problem solving. We found that students use domain-general and hybrid procedures more frequently when solving lower-order problems than higher-order problems, while they use domain-specific procedures more frequently when solving higher-order problems. Additionally, the more domain-specific procedures students used, the higher the likelihood that they would answer the problem correctly, up to five procedures. However, if students used just one domain-general procedure, they were as likely to answer the problem correctly as if they had used two to five domain-general procedures. Our findings provide a categorization scheme and framework for additional research on biology problem solving and suggest several important implications for researchers and instructors. PMID:27909021
Brick tunnel randomization and the momentum of the probability mass.
Kuznetsova, Olga M
2015-12-30
The allocation space of an unequal-allocation permuted block randomization can be quite wide. The development of unequal-allocation procedures with a narrower allocation space, however, is complicated by the need to preserve the unconditional allocation ratio at every step (the allocation ratio preserving (ARP) property). When the allocation paths are depicted on the K-dimensional unitary grid, where allocation to the l-th treatment is represented by a step along the l-th axis, l = 1 to K, the ARP property can be expressed in terms of the center of the probability mass after i allocations. Specifically, for an ARP allocation procedure that randomizes subjects to K treatment groups in w1 :⋯:wK ratio, w1 +⋯+wK =1, the coordinates of the center of the mass are (w1 i,…,wK i). In this paper, the momentum with respect to the center of the probability mass (expected imbalance in treatment assignments) is used to compare ARP procedures in how closely they approximate the target allocation ratio. It is shown that the two-arm and three-arm brick tunnel randomizations (BTR) are the ARP allocation procedures with the tightest allocation space among all allocation procedures with the same allocation ratio; the two-arm BTR is the minimum-momentum two-arm ARP allocation procedure. Resident probabilities of two-arm and three-arm BTR are analytically derived from the coordinates of the center of the probability mass; the existence of the respective transition probabilities is proven. Probability of deterministic assignments with BTR is found generally acceptable. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Saucedo-Reyes, Daniela; Carrillo-Salazar, José A; Román-Padilla, Lizbeth; Saucedo-Veloz, Crescenciano; Reyes-Santamaría, María I; Ramírez-Gilly, Mariana; Tecante, Alberto
2018-03-01
High hydrostatic pressure inactivation kinetics of Escherichia coli ATCC 25922 and Salmonella enterica subsp. enterica serovar Typhimurium ATCC 14028 ( S. typhimurium) in a low acid mamey pulp at four pressure levels (300, 350, 400, and 450 MPa), different exposure times (0-8 min), and temperature of 25 ± 2℃ were obtained. Survival curves showed deviations from linearity in the form of a tail (upward concavity). The primary models tested were the Weibull model, the modified Gompertz equation, and the biphasic model. The Weibull model gave the best goodness of fit ( R 2 adj > 0.956, root mean square error < 0.290) in the modeling and the lowest Akaike information criterion value. Exponential-logistic and exponential decay models, and Bigelow-type and an empirical models for b'( P) and n( P) parameters, respectively, were tested as alternative secondary models. The process validation considered the two- and one-step nonlinear regressions for making predictions of the survival fraction; both regression types provided an adequate goodness of fit and the one-step nonlinear regression clearly reduced fitting errors. The best candidate model according to the Akaike theory information, with better accuracy and more reliable predictions was the Weibull model integrated by the exponential-logistic and exponential decay secondary models as a function of time and pressure (two-step procedure) or incorporated as one equation (one-step procedure). Both mathematical expressions were used to determine the t d parameter, where the desired reductions ( 5D) (considering d = 5 ( t 5 ) as the criterion of 5 Log 10 reduction (5 D)) in both microorganisms are attainable at 400 MPa for 5.487 ± 0.488 or 5.950 ± 0.329 min, respectively, for the one- or two-step nonlinear procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, H; Chen, J
Purpose: Metal objects create severe artifacts in kilo-voltage (kV) CT image reconstructions due to the high attenuation coefficients of high atomic number objects. Most of the techniques devised to reduce this artifact utilize a two-step approach, which do not reliably yield the qualified reconstructed images. Thus, for accuracy and simplicity, this work presents a one-step reconstruction method based on a modified penalized weighted least-squares (PWLS) technique. Methods: Existing techniques for metal artifact reduction mostly adopt a two-step approach, which conduct additional reconstruction with the modified projection data from the initial reconstruction. This procedure does not consistently perform well due tomore » the uncertainties in manipulating the metal-contaminated projection data by thresholding and linear interpolation. This study proposes a one-step reconstruction process using a new PWLS operation with total-variation (TV) minimization, while not manipulating the projection. The PWLS for CT reconstruction has been investigated using a pre-defined weight, based on the variance of the projection datum at each detector bin. It works well when reconstructing CT images from metal-free projection data, which does not appropriately penalize metal-contaminated projection data. The proposed work defines the weight at each projection element under the assumption of a Poisson random variable. This small modification using element-wise penalization has a large impact in reducing metal artifacts. For evaluation, the proposed technique was assessed with two noisy, metal-contaminated digital phantoms, against the existing PWLS with TV minimization and the two-step approach. Result: The proposed PWLS with TV minimization greatly improved the metal artifact reduction, relative to the other techniques, by watching the results. Numerically, the new approach lowered the normalized root-mean-square error about 30 and 60% for the two cases, respectively, compared to the two-step method. Conclusion: A new PWLS operation shows promise for improving metal artifact reduction in CT imaging, as well as simplifying the reconstructing procedure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Egestad, B.; Curstedt, T.; Sjoevall, J.
1982-01-01
Procedures for enrichment of non-volatile chlorinated aromatic pollutants from fat, water and milk are described. /sup 14/C-DDT was used as a model compound in recovery experiments. A several thousand-fold enrichment of DDT added to butter was achieved by two consecutive straight-phase chromatographies on Lipidex 5000. Trace amounts of DDT in liter volumes of water could be quantitatively extracted by rapid filtration through 2 ml beds of Lipidex 1000. A batch extraction procedure permitted enrichment of DDT from milk after addition of n-pentylamine, methanol and water. DDT could then be eluted from the gel with retention of more than 90% ofmore » the lipids. A reversed-phase system with Lipidex 5000 could be used for separation of TCDD from DDT and PCBs. The liquid-gel chromatographic procedures are simple and suitable for clean-up of samples prior to application of high-resolution methods. 5 tables.« less
NASA Technical Reports Server (NTRS)
Baskharone, Erian A.
1993-01-01
This report describes the computational steps involved in executing a finite-element-based perturbation model for computing the rotor dynamic coefficients of a shrouded pump impeller or a simple seal. These arise from the fluid/rotor interaction in the clearance gap. In addition to the sample cases, the computational procedure also applies to a separate category of problems referred to as the 'seal-like' category. The problem, in this case, concerns a shrouded impeller, with the exception that the secondary, or leakage, passage is totally isolated from the primary-flow passage. The difference between this and the pump problem is that the former is analytically of the simple 'seal-like' configuration, with two (inlet and exit) flow-permeable stations, while the latter constitutes a double-entry / double-discharge flow problem. In all cases, the problem is that of a rotor clearance gap. The problem here is that of a rotor excitation in the form of a cylindrical whirl around the housing centerline for a smooth annular seal. In its centered operation mode, the rotor is assumed to give rise to an axisymmetric flow field in the clearance gap. As a result, problems involving longitudinal or helical grooves, in the rotor or housing surfaces, go beyond the code capabilities. Discarding, for the moment, the pre- and post-processing phases, the bulk of the computational procedure consists of two main steps. The first is aimed at producing the axisymmetric 'zeroth-order' flow solution in the given flow domain. Detailed description of this problem, including the flow-governing equations, turbulence closure, boundary conditions, and the finite-element formulation, was covered by Baskharone and Hensel. The second main step is where the perturbation model is implemented, with the input being the centered-rotor 'zeroth-order' flow solution and a prescribed whirl frequency ratio (whirl frequency divided by the impeller speed). The computational domain, in the latter case, is treated as three dimensional, with the number of computational planes in the circumferential direction being specified a priori. The reader is reminded that the deformations in the finite elements are all infinitesimally small because the rotor eccentricity itself is a virtual displacement. This explains why we have generically termed the perturbation model the 'virtually' deformable finite-element category. The primary outcome of implementing the perturbation model is the tangential and radial components, F(sub theta)(sup *) and F(sub r)(sup *) of the fluid-exerted force on the rotor surface due to the whirling motion. Repetitive execution of the perturbation model subprogram over a sufficient range of whirl frequency ratios, and subsequent interpolation of these fluid forces, using the least-square method, finally enable the user to compute the impeller rotor dynamic coefficients of the fluid/rotor interaction. These are the direct and cross-coupled stiffness, damping, and inertia effects of the fluid/rotor interaction.
A step-by-step solution for embedding user-controlled cines into educational Web pages.
Cornfeld, Daniel
2008-03-01
The objective of this article is to introduce a simple method for embedding user-controlled cines into a Web page using a simple JavaScript. Step-by-step instructions are included and the source code is made available. This technique allows the creation of portable Web pages that allow the user to scroll through cases as if seated at a PACS workstation. A simple JavaScript allows scrollable image stacks to be included on Web pages. With this technique, you can quickly and easily incorporate entire stacks of CT or MR images into online teaching files. This technique has the potential for use in case presentations, online didactics, teaching archives, and resident testing.
[Application of inner figure-of-eight suture to laparoscopic colorectal surgery].
Chen, Jianjun; Zhong, Ming
2018-03-25
Regardless of laparoscopic or open colorectal surgeries, intestinal anastomosis is usually an important operative procedure. Even if stapler is widely used in different intestinal surgery nowadays, hand sewn suture is an indispensable procedure in clinical practice, meanwhile after stapled anastomosis, additional hand sewn suture is usually performed to ensure the safety of anastomosis. The inner figure-of-eight suture is a single layer suture technique which has been widely used in skin, tendon, rectus and uterus for quick and secure approximation. We describe our innovative application of inner figure-of-eight suture technique for intestinal anastomosis and/or reinforcement after stapled anastomosis in laparoscopic colorectal surgery. Main steps of inner figure-of-eight suture for intestinal anastomosis on posterior wall are as follows: (1) At 4 mm from cut edge of bowel, needle enters vertically from one side and courses mucosa-serosa-opposite serosa-mucosa in parallel to the entry point. (2) The needle is brought back to first entry side of bowel at 45 degree to enter the mucosa 5 mm below the first entry point and out on opposite side mucosa horizontally. (3) Both lose ends of the suture are pulled to approximate bowel edges and knots are tied on mucosal surface, in which suture line presents figure-of-eight on mucosal surface and two parallel suture lines are seen on serosal surface. When inner figure-of-eight suture is performed on anterior wall, the procedure is similar, but needle passes from serosa-mucosa-opposite mucosa-serosa and repeated to complete the inner figure-8 suture and knots are tied on serosa. The final look is two parallel sutures at 0.5 mm in between and the figure-of-eight remains inside the lumen. We did not deliberately try to invert the bowel edges, and if anastomosis is not satisfactory at final examination, simple interrupted seromuscular suture can be carried out. From 2015 till now, we have successfully completed inner figure-of-eight sutures in 38 cases receiving intestinal anastomosis reinforcement procedure and in 24 cases receiving hand sewn anastomosis. Comparison study revealed inner figure-of-eight suture presented shorter anastomotic time and less medical cost without anastomotic leakage, stump leakage or bleeding. No anastomotic stenosis was found at enteroscopy examination during follow up. We think that inner figure-of-eight suture possesses safe and simple advantages and is a manual suture technique worthy of promotion.
Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.
Sparding, Nadja; Slotved, Hans-Christian; Nicolaisen, Gert M; Giese, Steen B; Elmlund, Jón; Steenhard, Nina R
2014-01-01
After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin) with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments) for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.
Rodríguez-Arias, Miquel Angel; Rodó, Xavier
2004-03-01
Here we describe a practical, step-by-step primer to scale-dependent correlation (SDC) analysis. The analysis of transitory processes is an important but often neglected topic in ecological studies because only a few statistical techniques appear to detect temporary features accurately enough. We introduce here the SDC analysis, a statistical and graphical method to study transitory processes at any temporal or spatial scale. SDC analysis, thanks to the combination of conventional procedures and simple well-known statistical techniques, becomes an improved time-domain analogue of wavelet analysis. We use several simple synthetic series to describe the method, a more complex example, full of transitory features, to compare SDC and wavelet analysis, and finally we analyze some selected ecological series to illustrate the methodology. The SDC analysis of time series of copepod abundances in the North Sea indicates that ENSO primarily is the main climatic driver of short-term changes in population dynamics. SDC also uncovers some long-term, unexpected features in the population. Similarly, the SDC analysis of Nicholson's blowflies data locates where the proposed models fail and provides new insights about the mechanism that drives the apparent vanishing of the population cycle during the second half of the series.
NASA Astrophysics Data System (ADS)
Sathya, Ayyappan; Kalyani, S.; Ranoo, Surojit; Philip, John
2017-10-01
To realize magnetic hyperthermia as an alternate stand-alone therapeutic procedure for cancer treatment, magnetic nanoparticles with optimal performance, within the biologically safe limits, are to be produced using simple, reproducible and scalable techniques. Herein, we present a simple, one-step approach for synthesis of water-dispersible magnetic nanoclusters (MNCs) of superparamagnetic iron oxide by reducing of Fe2(SO4)3 in sodium acetate (alkali), poly ethylene glycol (capping ligand), and ethylene glycol (solvent and reductant) in a microwave reactor. The average size and saturation magnetization of the MNC's are tuned from 27 to 52 nm and 32 to 58 emu/g by increasing the reaction time from 10 to 600 s. Transmission electron microscopy images reveal that each MNC composed of large number of primary Fe3O4 nanoparticles. The synthesised MNCs show excellent colloidal stability in aqueous phase due to the adsorbed PEG layer. The highest SAR value of 215 ± 10 W/gFe observed in 52 nm size MNC at a frequency of 126 kHz and field of 63 kA/m suggest the potential use of these MNC in hyperthermia applications. This study further opens up the possibilities to develop metal ion-doped MNCs with tunable sizes suitable for various biomedical applications using microwave assisted synthesis.
The Aristotle score: a complexity-adjusted method to evaluate surgical results.
Lacour-Gayet, F; Clarke, D; Jacobs, J; Comas, J; Daebritz, S; Daenen, W; Gaynor, W; Hamilton, L; Jacobs, M; Maruszsewski, B; Pozzi, M; Spray, T; Stellin, G; Tchervenkov, C; Mavroudis And, C
2004-06-01
Quality control is difficult to achieve in Congenital Heart Surgery (CHS) because of the diversity of the procedures. It is particularly needed, considering the potential adverse outcomes associated with complex cases. The aim of this project was to develop a new method based on the complexity of the procedures. The Aristotle project, involving a panel of expert surgeons, started in 1999 and included 50 pediatric surgeons from 23 countries, representing the EACTS, STS, ECHSA and CHSS. The complexity was based on the procedures as defined by the STS/EACTS International Nomenclature and was undertaken in two steps: the first step was establishing the Basic Score, which adjusts only the complexity of the procedures. It is based on three factors: the potential for mortality, the potential for morbidity and the anticipated technical difficulty. A questionnaire was completed by the 50 centers. The second step was the development of the Comprehensive Aristotle Score, which further adjusts the complexity according to the specific patient characteristics. It includes two categories of complexity factors, the procedure dependent and independent factors. After considering the relationship between complexity and performance, the Aristotle Committee is proposing that: Performance = Complexity x Outcome. The Aristotle score, allows precise scoring of the complexity for 145 CHS procedures. One interesting notion coming out of this study is that complexity is a constant value for a given patient regardless of the center where he is operated. The Aristotle complexity score was further applied to 26 centers reporting to the EACTS congenital database. A new display of centers is presented based on the comparison of hospital survival to complexity and to our proposed definition of performance. A complexity-adjusted method named the Aristotle Score, based on the complexity of the surgical procedures has been developed by an international group of experts. The Aristotle score, electronically available, was introduced in the EACTS and STS databases. A validation process evaluating its predictive value is being developed.
The minimization of ac phase noise in interferometric systems
NASA Astrophysics Data System (ADS)
Filinski, I.; Gordon, R. A.
1994-03-01
A simple step-by-step procedure, including several novel techniques discussed in the Appendices, is given for minimizing ac phase noise in typical interferometric systems such as two-beam interferometers, holographic setups, four-wave mixers, etc. Special attention is given to index of refraction fluctuations, direct mechanical coupling, and acoustic coupling, whose importance in determining ac phase noise in interferometric systems has not been adequately treated. The minimization procedure must be carried out while continuously monitoring the phase noise which can be done very simply by using a photodiode measurement of the interferometer output. Supplementary measurements using a microphone and accelerometer will also be helpful in identifying the sources of phase noise. Emphasis is placed on new techniques or new modifications of older techniques which will not usually be familiar to most workers in optics. Thus, the necessity of eliminating the effects of index of refraction fluctuations which degrade the performance of all interferometers is pointed out as the first priority. A substantial decrease of the effects of all vibrating, rotating, or flowing masses (e.g., cooling lines) in direct contact with the optical table will also have to be carefully carried out regardless of the type of interferometric system employed. It is recommended that this be followed by a simple, inexpensive change to a novel type of interferometer discussed in Appendix A which is inherently less sensitive to mechanical vibration. Such a change will lead to a reduction of both low-frequency and high-frequency ac phase noise by more than an order of magnitude and can be carried out for all interferometers with the exception of multiple pass optical systems and high-resolution FFT spectrometers. It is pointed out that most homemade air bladder vibration isolators are used incorrectly and do not provide sufficient reduction in the contribution of floor vibrations to phase noise. Several simple trampoline-type air bladder vibration isolator systems are described which are comparable in performance to commercial systems. With the exception of very nonrigid or undamped optical tables, the dominant source of ac phase noise at this point will usually be due to acoustic coupling to the optical components and mounts themselves. This means not only that the optical components and mounts must be rigid but that the mechanical coupling between the table and the mounts, as well as the coupling between the mounts and components themselves, be as rigid as possible. An additional damping of optical mounts beyond that generally found in commercial mountings will also have to be carried out to obtain a further reduction of phase noise. A simple damping technique employing an additional mass and an intermediate damping layer is described which will significantly improve the performance of both homemade and commercial optical mounts. Similar damping techniques which are especially suitable for homemade optical tables and breadboards are also considered.
Wenga, G; Jacques, E; Salaün, A-C; Rogel, R; Pichon, L; Geneste, F
2013-02-15
Currently, detection of DNA hybridization using fluorescence-based detection technique requires expensive optical systems and complex bioinformatics tools. Hence, the development of new low cost devices that enable direct and highly sensitive detection stimulates a lot of research efforts. Particularly, devices based on silicon nanowires are emerging as ultrasensitive electrical sensors for the direct detection of biological species thanks to their high surface to volume ratio. In this study, we propose innovative devices using step-gate polycrystalline silicon nanowire FET (poly-Si NW FETs), achieved with simple and low cost fabrication process, and used as ultrasensitive electronic sensor for DNA hybridization. The poly-SiNWs are synthesized using the sidewall spacer formation technique. The detailed fabrication procedure for a step-gate NWFET sensor is described in this paper. No-complementary and complementary DNA sequences were clearly discriminated and detection limit to 1 fM range is observed. This first result using this nano-device is promising for the development of low cost and ultrasensitive polysilicon nanowires based DNA sensors compatible with the CMOS technology. Copyright © 2012 Elsevier B.V. All rights reserved.
Barrasso, Roberta; Marchetti, Patrizia; Samoilis, Giorgio; Tantillo, Giuseppina; Ceci, Edmondo
2018-01-01
Simple Summary Cortisol and catecholamines (dopamine, norepinephrine and epinephrine) are released in response to stress and directly stimulate glycogen mobilization, thus influencing meat acidification. The aim of the study was to estimate and compare these stress indicators to evaluate the welfare of beef cattle, subjected to either traditional slaughtering (with stunning) or to slaughtering with religious Jewish rite (without stunning). Significant differences in plasma cortisol and catecholamine levels were observed during exsanguination by monitoring animals in the pre-slaughtering (before and after transportation) and slaughtering phases. Cortisol, dopamine and norepinephrine, but not epinephrine, were markedly higher in the animals slaughtered by the religious rite. Pursuing animal welfare in the religious slaughtering procedures could produce advantages in terms of hygiene, organoleptic quality and shelf life of meat. Abstract Sixty Charolais male beef cattle of eight months of age were divided into two groups according to the slaughtering method, i.e., traditional or Kosher (religious Jewish rite). The aim of the study was to detect and compare the plasma concentrations of cortisol and catecholamines (dopamine, norepinephrine and epinephrine), by Elisa and HPLC test. These four stress indicators were evaluated during three different stages of each animal productive life: on the farm (step 1), after transportation (step 2) and during bleeding (step 3). The patterns of the parameters measured were similar and, interestingly, revealed significant changes throughout the three steps considered. The greatest variation between the two methods of slaughtering was observed in step 3, where we found a statistically significant difference with all the parameters except epinephrine. In the animals slaughtered by the religious rite, cortisol, dopamine, norepinephrine and epinephrine were 68.70 ± 30.61 nmol/L; 868.43 ± 508.52 ng/L; 3776.20 ± 1918.44 ng/L; and 4352.20 ± 3730.15 ng/L, respectively, versus 45.08 ± 14.15 nmol/L; 513.87 ± 286.32 ng/L; 3425.57 ± 1777.39 ng/L; and 3279.97 ± 1954.53 ng/L, respectively, in the other animals. This suggests that the animals slaughtered by the Kosher rite are subjected to higher stress conditions at the exsanguination phase. The animals slaughtered by the religious Jewish rite showed lower cortisol and catecholamine levels on the farm (step 1) and after transportation to the slaughterhouse (step 2). This was likely because the animals selected at the end of step 1 by the Rabbis for the religious rite are usually the most docile and gentle. PMID:29561752
Grain Yield Observations Constrain Cropland CO2 Fluxes Over Europe
NASA Astrophysics Data System (ADS)
Combe, M.; de Wit, A. J. W.; Vilà-Guerau de Arellano, J.; van der Molen, M. K.; Magliulo, V.; Peters, W.
2017-12-01
Carbon exchange over croplands plays an important role in the European carbon cycle over daily to seasonal time scales. A better description of this exchange in terrestrial biosphere models—most of which currently treat crops as unmanaged grasslands—is needed to improve atmospheric CO2 simulations. In the framework we present here, we model gross European cropland CO2 fluxes with a crop growth model constrained by grain yield observations. Our approach follows a two-step procedure. In the first step, we calculate day-to-day crop carbon fluxes and pools with the WOrld FOod STudies (WOFOST) model. A scaling factor of crop growth is optimized regionally by minimizing the final grain carbon pool difference to crop yield observations from the Statistical Office of the European Union. In a second step, we re-run our WOFOST model for the full European 25 × 25 km gridded domain using the optimized scaling factors. We combine our optimized crop CO2 fluxes with a simple soil respiration model to obtain the net cropland CO2 exchange. We assess our model's ability to represent cropland CO2 exchange using 40 years of observations at seven European FluxNet sites and compare it with carbon fluxes produced by a typical terrestrial biosphere model. We conclude that our new model framework provides a more realistic and strongly observation-driven estimate of carbon exchange over European croplands. Its products will be made available to the scientific community through the ICOS Carbon Portal and serve as a new cropland component in the CarbonTracker Europe inverse model.
Walk on Floor Eyes Closed Test as a Measure of Postflight Ataxia
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Fisher, E. A.; Kofman, I. S.; Cerisano, J. M.; Harm, D.L.; Peters, B. T.; Bloomberg, J. J.
2010-01-01
INTRODUCTION: Astronauts returning from space flight universally exhibit impaired posture and locomotion. Measurement of this impairment is an evolving process. The walk on the floor line test with the eyes closed (WOFEC) provides a unique procedure for quantifying postflight ataxia. Data from a modified WOFEC were obtained as part of an ongoing NASA interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate astronaut postflight functional performance. METHODS: Seven astronauts (5 short duration with flights of 12-16 days; 2 long duration crewmembers with flights of 6 months) were tested twice before flight, on landing day (short duration only), and 1, 6, and 30 days after flight. The WOFEC consisted of walking for 10 steps (repeated twice) with the feet heel to toe in tandem, arms folded across the chest and the eyes closed. The performance metric (scored by three examiners from video) was the percentage of correct steps completed over the three trials. A step was not counted as correct if the crewmember sidestepped, opened their eyes, or paused for more than three seconds between steps. RESULTS/ CONCLUSIONS: There was a significant decrease in percentage of correct steps on landing day (short duration crew) and on first day following landing (long duration) with partial recovery the following day, and full recovery beginning on day sixth after flight. Both short and long duration fliers appeared to be unaware of foot position relative to their bodies or the floor. Postflight, deviation from a straight path was common, and the test for two crewmembers elicited motion sickness symptoms. These data clearly demonstrate the sensorimotor challenges facing crewmembers after returning from spaceflight. The WOFEC test has value providing the investigator or crew surgeon with a simple method to quantify vestibular ataxia, as well as providing instant feedback of postural ataxia without the use of complex test equipment.
Alternator insulation evaluation tests
NASA Technical Reports Server (NTRS)
Penn, W. B.; Schaefer, R. F.; Balke, R. L.
1972-01-01
Tests were conducted to predict the remaining electrical insulation life of a 60 KW homopolar inductor alternator following completion of NASA turbo-alternator endurance tests for SNAP-8 space electrical power systems application. The insulation quality was established for two alternators following completion of these tests. A step-temperature aging test procedure was developed for insulation life prediction and applied to one of the two alternators. Armature winding insulation life of over 80,000 hours for an average winding temperature of 248 degrees C was predicted using the developed procedure.
AKAPS Act in a Two-Step Mechanism of Memory Acquisition
Scheunemann, Lisa; Skroblin, Philipp; Hundsrucker, Christian; Klussmann, Enno; Efetova, Marina
2013-01-01
Defining the molecular and neuronal basis of associative memories is based upon behavioral preparations that yield high performance due to selection of salient stimuli, strong reinforcement, and repeated conditioning trials. One of those preparations is the Drosophila aversive olfactory conditioning procedure where animals initiate multiple memory components after experience of a single cycle training procedure. Here, we explored the analysis of acquisition dynamics as a means to define memory components and revealed strong correlations between particular chronologies of shock impact and number experienced during the associative training situation and subsequent performance of conditioned avoidance. Analyzing acquisition dynamics in Drosophila memory mutants revealed that rutabaga (rut)-dependent cAMP signals couple in a divergent fashion for support of different memory components. In case of anesthesia-sensitive memory (ASM) we identified a characteristic two-step mechanism that links rut-AC1 to A-kinase anchoring proteins (AKAP)-sequestered protein kinase A at the level of Kenyon cells, a recognized center of olfactory learning within the fly brain. We propose that integration of rut-derived cAMP signals at level of AKAPs might serve as counting register that accounts for the two-step mechanism of ASM acquisition. PMID:24174675
NASA Astrophysics Data System (ADS)
Izyumskaya, N.; Okur, S.; Zhang, F.; Monavarian, M.; Avrutin, V.; Özgür, Ü.; Metzner, S.; Karbaum, C.; Bertram, F.; Christen, J.; Morkoç, H.
2014-03-01
Nonpolar m-plane GaN layers were grown on patterned Si (112) substrates by metal-organic chemical vapor deposition (MOCVD). A two-step growth procedure involving a low-pressure (30 Torr) first step to ensure formation of the m-plane facet and a high-pressure step (200 Torr) for improvement of optical quality was employed. The layers grown in two steps show improvement of the optical quality: the near-bandedge photoluminescence (PL) intensity is about 3 times higher than that for the layers grown at low pressure, and deep emission is considerably weaker. However, emission intensity from m-GaN is still lower than that of polar and semipolar (1 100 ) reference samples grown under the same conditions. To shed light on this problem, spatial distribution of optical emission over the c+ and c- wings of the nonpolar GaN/Si was studied by spatially resolved cathodoluminescence and near-field scanning optical microscopy.
On the Possibility of Ill-Conditioned Covariance Matrices in the First-Order Two-Step Estimator
NASA Technical Reports Server (NTRS)
Garrison, James L.; Axelrod, Penina; Kasdin, N. Jeremy
1997-01-01
The first-order two-step nonlinear estimator, when applied to a problem of orbital navigation, is found to occasionally produce first step covariance matrices with very low eigenvalues at certain trajectory points. This anomaly is the result of the linear approximation to the first step covariance propagation. The study of this anomaly begins with expressing the propagation of the first and second step covariance matrices in terms of a single matrix. This matrix is shown to have a rank equal to the difference between the number of first step states and the number of second step states. Furthermore, under some simplifying assumptions, it is found that the basis of the column space of this matrix remains fixed once the filter has removed the large initial state error. A test matrix containing the basis of this column space and the partial derivative matrix relating first and second step states is derived. This square test matrix, which has dimensions equal to the number of first step states, numerically drops rank at the same locations that the first step covariance does. It is formulated in terms of a set of constant vectors (the basis) and a matrix which can be computed from a reference trajectory (the partial derivative matrix). A simple example problem involving dynamics which are described by two states and a range measurement illustrate the cause of this anomaly and the application of the aforementioned numerical test in more detail.
Quantum neural network-based EEG filtering for a brain-computer interface.
Gandhi, Vaibhav; Prasad, Girijesh; Coyle, Damien; Behera, Laxmidhar; McGinnity, Thomas Martin
2014-02-01
A novel neural information processing architecture inspired by quantum mechanics and incorporating the well-known Schrodinger wave equation is proposed in this paper. The proposed architecture referred to as recurrent quantum neural network (RQNN) can characterize a nonstationary stochastic signal as time-varying wave packets. A robust unsupervised learning algorithm enables the RQNN to effectively capture the statistical behavior of the input signal and facilitates the estimation of signal embedded in noise with unknown characteristics. The results from a number of benchmark tests show that simple signals such as dc, staircase dc, and sinusoidal signals embedded within high noise can be accurately filtered and particle swarm optimization can be employed to select model parameters. The RQNN filtering procedure is applied in a two-class motor imagery-based brain-computer interface where the objective was to filter electroencephalogram (EEG) signals before feature extraction and classification to increase signal separability. A two-step inner-outer fivefold cross-validation approach is utilized to select the algorithm parameters subject-specifically for nine subjects. It is shown that the subject-specific RQNN EEG filtering significantly improves brain-computer interface performance compared to using only the raw EEG or Savitzky-Golay filtered EEG across multiple sessions.
Unsupervised color image segmentation using a lattice algebra clustering technique
NASA Astrophysics Data System (ADS)
Urcid, Gonzalo; Ritter, Gerhard X.
2011-08-01
In this paper we introduce a lattice algebra clustering technique for segmenting digital images in the Red-Green- Blue (RGB) color space. The proposed technique is a two step procedure. Given an input color image, the first step determines the finite set of its extreme pixel vectors within the color cube by means of the scaled min-W and max-M lattice auto-associative memory matrices, including the minimum and maximum vector bounds. In the second step, maximal rectangular boxes enclosing each extreme color pixel are found using the Chebychev distance between color pixels; afterwards, clustering is performed by assigning each image pixel to its corresponding maximal box. The two steps in our proposed method are completely unsupervised or autonomous. Illustrative examples are provided to demonstrate the color segmentation results including a brief numerical comparison with two other non-maximal variations of the same clustering technique.
A Simple Method to Determine the Refractive Index of Glass.
ERIC Educational Resources Information Center
Mak, Se-yuen
1988-01-01
Describes an experiment for determining the refractive index. Discusses the experiment procedure and mathematical expression for calculating the index. Provides two geometrical diagrams and a graph for determining the index with a typical data. (YP)
Markopoulos, Georgios
2012-01-01
Summary This review describes the preparation, structural properties and the use of bisallenes in organic synthesis for the first time. All classes of compounds containing at least two allene moieties are considered, starting from simple conjugated bisallenes and ending with allenes in which the two cumulenic units are connected by complex polycyclic ring systems, heteroatoms and/or heteroatom-containing tethers. Preparatively the bisallenes are especially useful in isomerization and cycloaddition reactions of all kinds leading to the respective target molecules with high atom economy and often in high yield. Bisallenes are hence substrates for generating molecular complexity in a small number of steps (high step economy). PMID:23209534
ERIC Educational Resources Information Center
Madu, B. C.
2012-01-01
The study explored the efficacy of four-step (4-E) learning cycle approach on students understanding of concepts related to Simple Harmonic Motion (SHM). 124 students (63 for experimental group and 61 for control group) participated in the study. The students' views and ideas in simple Harmonic Achievement test were analyzed qualitatively. The…
Semiotics and semiology of Nursing: evaluation of undergraduate students' knowledge on procedures.
Melo, Gabriela de Sousa Martins; Tibúrcio, Manuela Pinto; Freitas, Camylla Cavalcante Soares de; Vasconcelos, Quinídia Lúcia Duarte de Almeida Quithé de; Costa, Isabel Karolyne Fernandes; Torres, Gilson de Vasconcelos
2017-04-01
to assess the knowledge of scholars on Nursing regarding simple hands hygiene (SHH), blood pressure measurement (BP), peripheral venipuncture (PV) with venous catheter and male urethral catheterization delay (UCD) procedures. quantitative study carried out between February and May 2014, with 186 undergraduate Nursing students from 5th to 9th period of a public university of Rio Grande do Norte, with application of four questionnaires. One carried out descriptive and analytic analysis. the students presented low average percentage of right answers, especially in blood pressure measurement (55.5%); SHH's average was higher than 70%. The average of correct answers was the highest in SHH (8.6), followed by UCD (7.8), PV (7.4) and BP (6.7). The questions regarding the topic "concepts" showed less correct answers when comparing it to the topic "technique steps". it is necessary to establish knowledge monitoring strategies, in order to stimulate the constant improvement.
Self-constrained inversion of potential fields
NASA Astrophysics Data System (ADS)
Paoletti, V.; Ialongo, S.; Florio, G.; Fedi, M.; Cella, F.
2013-11-01
We present a potential-field-constrained inversion procedure based on a priori information derived exclusively from the analysis of the gravity and magnetic data (self-constrained inversion). The procedure is designed to be applied to underdetermined problems and involves scenarios where the source distribution can be assumed to be of simple character. To set up effective constraints, we first estimate through the analysis of the gravity or magnetic field some or all of the following source parameters: the source depth-to-the-top, the structural index, the horizontal position of the source body edges and their dip. The second step is incorporating the information related to these constraints in the objective function as depth and spatial weighting functions. We show, through 2-D and 3-D synthetic and real data examples, that potential field-based constraints, for example, structural index, source boundaries and others, are usually enough to obtain substantial improvement in the density and magnetization models.
A general multiblock Euler code for propulsion integration. Volume 3: User guide for the Euler code
NASA Technical Reports Server (NTRS)
Chen, H. C.; Su, T. Y.; Kao, T. J.
1991-01-01
This manual explains the procedures for using the general multiblock Euler (GMBE) code developed under NASA contract NAS1-18703. The code was developed for the aerodynamic analysis of geometrically complex configurations in either free air or wind tunnel environments (vol. 1). The complete flow field is divided into a number of topologically simple blocks within each of which surface fitted grids and efficient flow solution algorithms can easily be constructed. The multiblock field grid is generated with the BCON procedure described in volume 2. The GMBE utilizes a finite volume formulation with an explicit time stepping scheme to solve the Euler equations. A multiblock version of the multigrid method was developed to accelerate the convergence of the calculations. This user guide provides information on the GMBE code, including input data preparations with sample input files and a sample Unix script for program execution in the UNICOS environment.
Identifying fMRI Model Violations with Lagrange Multiplier Tests
Cassidy, Ben; Long, Christopher J; Rae, Caroline; Solo, Victor
2013-01-01
The standard modeling framework in Functional Magnetic Resonance Imaging (fMRI) is predicated on assumptions of linearity, time invariance and stationarity. These assumptions are rarely checked because doing so requires specialised software, although failure to do so can lead to bias and mistaken inference. Identifying model violations is an essential but largely neglected step in standard fMRI data analysis. Using Lagrange Multiplier testing methods we have developed simple and efficient procedures for detecting model violations such as non-linearity, non-stationarity and validity of the common Double Gamma specification for hemodynamic response. These procedures are computationally cheap and can easily be added to a conventional analysis. The test statistic is calculated at each voxel and displayed as a spatial anomaly map which shows regions where a model is violated. The methodology is illustrated with a large number of real data examples. PMID:22542665
Linear MALDI-ToF simultaneous spectrum deconvolution and baseline removal.
Picaud, Vincent; Giovannelli, Jean-Francois; Truntzer, Caroline; Charrier, Jean-Philippe; Giremus, Audrey; Grangeat, Pierre; Mercier, Catherine
2018-04-05
Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.
Salas, Rosa Ana; Pleite, Jorge
2013-01-01
We propose a specific procedure to compute the inductance of a toroidal ferrite core as a function of the excitation current. The study includes the linear, intermediate and saturation regions. The procedure combines the use of Finite Element Analysis in 2D and experimental measurements. Through the two dimensional (2D) procedure we are able to achieve convergence, a reduction of computational cost and equivalent results to those computed by three dimensional (3D) simulations. The validation is carried out by comparing 2D, 3D and experimental results. PMID:28809283
Analytical and numerical analysis of frictional damage in quasi brittle materials
NASA Astrophysics Data System (ADS)
Zhu, Q. Z.; Zhao, L. Y.; Shao, J. F.
2016-07-01
Frictional sliding and crack growth are two main dissipation processes in quasi brittle materials. The frictional sliding along closed cracks is the origin of macroscopic plastic deformation while the crack growth induces a material damage. The main difficulty of modeling is to consider the inherent coupling between these two processes. Various models and associated numerical algorithms have been proposed. But there are so far no analytical solutions even for simple loading paths for the validation of such algorithms. In this paper, we first present a micro-mechanical model taking into account the damage-friction coupling for a large class of quasi brittle materials. The model is formulated by combining a linear homogenization procedure with the Mori-Tanaka scheme and the irreversible thermodynamics framework. As an original contribution, a series of analytical solutions of stress-strain relations are developed for various loading paths. Based on the micro-mechanical model, two numerical integration algorithms are exploited. The first one involves a coupled friction/damage correction scheme, which is consistent with the coupling nature of the constitutive model. The second one contains a friction/damage decoupling scheme with two consecutive steps: the friction correction followed by the damage correction. With the analytical solutions as reference results, the two algorithms are assessed through a series of numerical tests. It is found that the decoupling correction scheme is efficient to guarantee a systematic numerical convergence.
ERIC Educational Resources Information Center
Rockwood, Stacy F.
This paper outlines the procedures used at the University of Cincinnati for establishing a field based elementary teacher education program in the form of a field guide. The first step involves a meeting with university faculty to discuss the implications of such a program. Step two involves meeting with the elementary school principal and selling…
Superhydrophobic aluminum alloy surfaces by a novel one-step process.
Saleema, N; Sarkar, D K; Paynter, R W; Chen, X-G
2010-09-01
A simple one-step process has been developed to render aluminum alloy surfaces superhydrophobic by immersing the aluminum alloy substrates in a solution containing NaOH and fluoroalkyl-silane (FAS-17) molecules. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and water contact angle measurements have been performed to characterize the morphological features, chemical composition and superhydrophobicity of the surfaces. The resulting surfaces provided a water contact angle as high as ∼162° and a contact angle hysteresis as low as ∼4°. The study indicates that it is possible to fabricate superhydrophobic aluminum surfaces easily and effectively without involving the traditional two-step processes.
Étalement d'une goutte stratifiée incompressible
NASA Astrophysics Data System (ADS)
de Gennes, Pierre-Gilles; Cazabat, Anne-Marie
L'étalement de films ultraminces de liquides simples sur une surface lisse horizontale conduit souvent à des gouttes à gradins d'une épaisseur moléculaire ([1]-[3]). Nous construisons ici un modèle pour la dynamique de l'étalement, en supposant que : (a) chaque gradin est un liquide bidimensionnel incompressible; (b) les molécules de la n-ième couche sont soumises à un potentiel (Wn) qui exprime leurs interactions à longue portée avec le solide; (c) on a un écoulement parallèle de cisaillement, et un écoulement normal de perméation. La perméation intervient seulement dans un certain « ruban » de largeur ξ sur le bord de chaque gradin. Dans le cas usuel, où le rayon du n-ième gradin Rn est trs supérieur à ξ, la dissipation est dominée par le cisaillement, et on arrive à des lois simples pour la vitesse de dilatation (ou de contraction) dotR_n. Very thin films of simple liquids often spread with well defined steps of molecular thickness ([1]-[3]). We construct a model for the dynamics of spreading assuming that: (a) each layer is an incompressible, 2 dimensional fluid; (b) the molecules in the (nth) layer experience a long range potential (e.g. Van der Waals) from the solid; (c) two types of flow occur: shear between layers and permeation normal to the layers. We find that permeation is important only in an annulus of small size ξ near each step. Between steps, the viscous effects in simple shear dominate, and this leads to simple laws for the dilation (or contraction) of the various layers.
Nilsson, O Rickard; Lannergård, Jonas; Morgan, B Paul; Lindahl, Gunnar; Gustafsson, Mattias C U
2013-01-01
Recent studies indicate that defective activity of complement factor H (FH) is associated with several human diseases, suggesting that pure FH may be used for therapy. Here, we describe a simple method to isolate human FH, based on the specific interaction between FH and the hypervariable region (HVR) of certain Streptococcus pyogenes M proteins. Special interest was focused on the FH polymorphism Y402H, which is associated with the common eye disease age-related macular degeneration (AMD) and has also been implicated in the binding to M protein. Using a fusion protein containing two copies of the M5-HVR, we found that the Y402 and H402 variants of FH could be efficiently purified by single-step affinity chromatography from human serum containing the corresponding protein. Different M proteins vary in their binding properties, and the M6 and M5 proteins, but not the M18 protein, showed selective binding of the FH Y402 variant. Accordingly, chromatography on a fusion protein derived from the M6-HVR allowed enrichment of the Y402 protein from serum containing both variants. Thus, the exquisite binding specificity of a bacterial protein can be exploited to develop a simple and robust procedure to purify FH and to enrich for the FH variant that protects against AMD.
Efficient production of glycosylated Cypridina luciferase using plant cells.
Mitani, Yasuo; Oshima, Yoshimi; Mitsuda, Nobutaka; Tomioka, Azusa; Sukegawa, Masako; Fujita, Mika; Kaji, Hiroyuki; Ohmiya, Yoshihiro
2017-05-01
Cypridina noctiluca luciferase has been utilized for biochemical and molecular biological applications, including bioluminescent enzyme immunoassays, far-red luminescence imaging, and high-throughput reporter assays. Some of these applications require a large amount of purified luciferase. However, conventional protein expression systems are not capable of producing sufficient quantities of protein with a high quality and purity without laborious and costly purification processes. To improve the productivity and expand the breadth of possibilities for Cypridina luciferase applications, we employed a variety of secretion expression systems, including yeast, mammalian cells, and silk worms. In this study, we established a simple production procedure using plant cell cultures. The plant cell culture BY-2 efficiently secreted luciferase, which was easily purified using a simple one-step ion-exchange chromatography method. The production yield was 20-30 mg of luciferase per liter of culture medium, and its Km for the luciferin (0.45 μM) was similar to that of the native protein. Additionally, we characterized its glycosylation pattern and confirmed that the two potential N-glycosylation sites were modified with plant-type oligosaccharide chains. Interestingly, the oligosaccharide chains could be trimmed without any detectable decrease in recombinant protein activity. Therefore, the results of our study indicate that this method offers a more cost-effective production method for Cypridina luciferase than conventional methods. Copyright © 2017 Elsevier Inc. All rights reserved.
Davison, James A
2015-01-01
Purpose To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. Patients and methods A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Results Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. Conclusion A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer. PMID:26355695
"Nailing" the management of the ingrown great toenail.
Block, Stan L
2014-11-01
"Nailing" the management of the severely ingrown great toenail, commonly encountered in the adolescent population, is an important tool in the pediatrician's armamentarium. I have found great toenail removal to be worthwhile, with straightforward indications; and quite rewarding for my patients in terms of time, convenience, and costs. The key to the procedure is to keep it simple. Four basic vital steps are involved: (1) operative permit and explanation; (2) performing a careful complete digital nerve block; (3) removing the entire toenail; and, importantly, (4) performing a partial chemical matricectomy--with readily available silver nitrate sticks--to prevent frequent recurrences. Copyright 2014, SLACK Incorporated.
Promoting Spontaneous Second Harmonic Generation through Organogelation.
Marco, A Belén; Aparicio, Fátima; Faour, Lara; Iliopoulos, Konstantinos; Morille, Yohann; Allain, Magali; Franco, Santiago; Andreu, Raquel; Sahraoui, Bouchta; Gindre, Denis; Canevet, David; Sallé, Marc
2016-07-27
An organogelator based on the Disperse Red nonlinear optical chromophore was synthesized according to a simple and efficient three-step procedure. The supramolecular gel organization leads to xerogels which display a spontaneous second harmonic generation (SHG) response without any need for preprocessing, and this SHG activity appears to be stable over several months. These findings, based on an intrinsic structural approach, are supported by favorable intermolecular supramolecular interactions, which promote a locally non-centrosymmetric NLO-active organization. This is in sharp contrast with most materials designed for SHG purposes, which generally require the use of expensive or heavy-to-handle external techniques for managing the dipoles' alignment.
NASA Astrophysics Data System (ADS)
Singh, R. A.; Satyanarayana, N.; Kustandi, T. S.; Sinha, S. K.
2011-01-01
Micro/nano-electro-mechanical-systems (MEMS/NEMS) are miniaturized devices built at micro/nanoscales. At these scales, the surface/interfacial forces are extremely strong and they adversely affect the smooth operation and the useful operating lifetimes of such devices. When these forces manifest in severe forms, they lead to material removal and thereby reduce the wear durability of the devices. In this paper, we present a simple, yet robust, two-step surface modification method to significantly enhance the tribological performance of MEMS/NEMS materials. The two-step method involves oxygen plasma treatment of polymeric films and the application of a nanolubricant, namely perfluoropolyether. We apply the two-step method to the two most important MEMS/NEMS structural materials, namely silicon and SU8 polymer. On applying surface modification to these materials, their initial coefficient of friction reduces by ~4-7 times and the steady-state coefficient of friction reduces by ~2.5-3.5 times. Simultaneously, the wear durability of both the materials increases by >1000 times. The two-step method is time effective as each of the steps takes the time duration of approximately 1 min. It is also cost effective as the oxygen plasma treatment is a part of the MEMS/NEMS fabrication process. The two-step method can be readily and easily integrated into MEMS/NEMS fabrication processes. It is anticipated that this method will work for any kind of structural material from which MEMS/NEMS are or can be made.
Test Equality between Three Treatments under an Incomplete Block Crossover Design.
Lui, Kung-Jong
2015-01-01
Under a random effects linear additive risk model, we compare two experimental treatments with a placebo in continuous data under an incomplete block crossover trial. We develop three test procedures for simultaneously testing equality between two experimental treatments and a placebo, as well as interval estimators for the mean difference between treatments. We apply Monte Carlo simulations to evaluate the performance of these test procedures and interval estimators in a variety of situations. We note that the bivariate test procedure accounting for the dependence structure based on the F-test is preferable to the other two procedures when there is only one of the two experimental treatments has a non-zero effect vs. the placebo. We note further that when the effects of the two experimental treatments vs. a placebo are in the same relative directions and are approximately of equal magnitude, the summary test procedure based on a simple average of two weighted-least-squares (WLS) estimators can outperform the other two procedures with respect to power. When one of the two experimental treatments has a relatively large effect vs. the placebo, the univariate test procedure with using Bonferroni's equality can be still of use. Finally, we use the data about the forced expiratory volume in 1 s (FEV1) readings taken from a double-blind crossover trial comparing two different doses of formoterol with a placebo to illustrate the use of test procedures and interval estimators proposed here.
Emergence of an optimal search strategy from a simple random walk
Sakiyama, Tomoko; Gunji, Yukio-Pegio
2013-01-01
In reports addressing animal foraging strategies, it has been stated that Lévy-like algorithms represent an optimal search strategy in an unknown environment, because of their super-diffusion properties and power-law-distributed step lengths. Here, starting with a simple random walk algorithm, which offers the agent a randomly determined direction at each time step with a fixed move length, we investigated how flexible exploration is achieved if an agent alters its randomly determined next step forward and the rule that controls its random movement based on its own directional moving experiences. We showed that our algorithm led to an effective food-searching performance compared with a simple random walk algorithm and exhibited super-diffusion properties, despite the uniform step lengths. Moreover, our algorithm exhibited a power-law distribution independent of uniform step lengths. PMID:23804445
Emergence of an optimal search strategy from a simple random walk.
Sakiyama, Tomoko; Gunji, Yukio-Pegio
2013-09-06
In reports addressing animal foraging strategies, it has been stated that Lévy-like algorithms represent an optimal search strategy in an unknown environment, because of their super-diffusion properties and power-law-distributed step lengths. Here, starting with a simple random walk algorithm, which offers the agent a randomly determined direction at each time step with a fixed move length, we investigated how flexible exploration is achieved if an agent alters its randomly determined next step forward and the rule that controls its random movement based on its own directional moving experiences. We showed that our algorithm led to an effective food-searching performance compared with a simple random walk algorithm and exhibited super-diffusion properties, despite the uniform step lengths. Moreover, our algorithm exhibited a power-law distribution independent of uniform step lengths.
Lorenz, Matthew A.; Burant, Charles F.; Kennedy, Robert T.
2011-01-01
A simple, fast, and reproducible sample preparation procedure was developed for relative quantification of metabolites in adherent mammalian cells using the clonal β-cell line INS-1 as a model sample. The method was developed by evaluating the effect of different sample preparation procedures on high performance liquid chromatography- mass spectrometry quantification of 27 metabolites involved in glycolysis and the tricarboxylic acid cycle on a directed basis as well as for all detectable chromatographic features on an undirected basis. We demonstrate that a rapid water rinse step prior to quenching of metabolism reduces components that suppress electrospray ionization thereby increasing signal for 26 of 27 targeted metabolites and increasing total number of detected features from 237 to 452 with no detectable change of metabolite content. A novel quenching technique is employed which involves addition of liquid nitrogen directly to the culture dish and allows for samples to be stored at −80 °C for at least 7 d before extraction. Separation of quenching and extraction steps provides the benefit of increased experimental convenience and sample stability while maintaining metabolite content similar to techniques that employ simultaneous quenching and extraction with cold organic solvent. The extraction solvent 9:1 methanol: chloroform was found to provide superior performance over acetonitrile, ethanol, and methanol with respect to metabolite recovery and extract stability. Maximal recovery was achieved using a single rapid (~1 min) extraction step. The utility of this rapid preparation method (~5 min) was demonstrated through precise metabolite measurements (11% average relative standard deviation without internal standards) associated with step changes in glucose concentration that evoke insulin secretion in the clonal β-cell line INS-1. PMID:21456517
Object Segmentation and Ground Truth in 3D Embryonic Imaging.
Rajasekaran, Bhavna; Uriu, Koichiro; Valentin, Guillaume; Tinevez, Jean-Yves; Oates, Andrew C
2016-01-01
Many questions in developmental biology depend on measuring the position and movement of individual cells within developing embryos. Yet, tools that provide this data are often challenged by high cell density and their accuracy is difficult to measure. Here, we present a three-step procedure to address this problem. Step one is a novel segmentation algorithm based on image derivatives that, in combination with selective post-processing, reliably and automatically segments cell nuclei from images of densely packed tissue. Step two is a quantitative validation using synthetic images to ascertain the efficiency of the algorithm with respect to signal-to-noise ratio and object density. Finally, we propose an original method to generate reliable and experimentally faithful ground truth datasets: Sparse-dense dual-labeled embryo chimeras are used to unambiguously measure segmentation errors within experimental data. Together, the three steps outlined here establish a robust, iterative procedure to fine-tune image analysis algorithms and microscopy settings associated with embryonic 3D image data sets.
Object Segmentation and Ground Truth in 3D Embryonic Imaging
Rajasekaran, Bhavna; Uriu, Koichiro; Valentin, Guillaume; Tinevez, Jean-Yves; Oates, Andrew C.
2016-01-01
Many questions in developmental biology depend on measuring the position and movement of individual cells within developing embryos. Yet, tools that provide this data are often challenged by high cell density and their accuracy is difficult to measure. Here, we present a three-step procedure to address this problem. Step one is a novel segmentation algorithm based on image derivatives that, in combination with selective post-processing, reliably and automatically segments cell nuclei from images of densely packed tissue. Step two is a quantitative validation using synthetic images to ascertain the efficiency of the algorithm with respect to signal-to-noise ratio and object density. Finally, we propose an original method to generate reliable and experimentally faithful ground truth datasets: Sparse-dense dual-labeled embryo chimeras are used to unambiguously measure segmentation errors within experimental data. Together, the three steps outlined here establish a robust, iterative procedure to fine-tune image analysis algorithms and microscopy settings associated with embryonic 3D image data sets. PMID:27332860
NASA Astrophysics Data System (ADS)
Park, Jung-Yong; Jung, Yong-Keun; Park, Jong-Jin; Kang, Yong-Ho
2002-05-01
Failures of turbine blades are identified as the leading causes of unplanned outages for steam turbine. Accidents of low-pressure turbine blade occupied more than 70 percent in turbine components. Therefore, the prevention of failures for low pressure turbine blades is certainly needed. The procedure is illustrated by the case study. This procedure is used to guide, and support the plant manager's decisions to avoid a costly, unplanned outage. In this study, we are trying to find factors of failures in LP turbine blade and to make three steps to approach the solution of blade failure. First step is to measure natural frequency in mockup test and to compare it with nozzle passing frequency. Second step is to use FEM and to calculate the natural frequencies of 7 blades and 10 blades per group in BLADE code. Third step is to find natural frequencies of grouped blade off the nozzle passing frequency.
NASA Astrophysics Data System (ADS)
Miao, Liming; Cheng, Xiaoliang; Chen, Haotian; Song, Yu; Guo, Hang; Zhang, Jinxin; Chen, Xuexian; Zhang, Haixia
2018-01-01
We report a simple method for fabricating two-dimensional and nested hierarchical wrinkle structures on polydimethylsiloxane surfaces via one-step C4F8 plasma treatment that innovatively combines two approaches to monolayer wrinkle structure fabrication. The wavelengths of the two dimensions of the wrinkle structures can be controlled by plasma treatment (radio frequency (RF) power and plasma treatment time) and stretching (stretching strain and axial stretching), respectively. We also analyze the different interactions between the two dimensions of wrinkle structures with different wavelengths and explain the phenomenon using Fourier waveform superposition. The character of the two dimensions and hierarchy is obvious when the wavelengths of the two wrinkles are different. In surface wetting tests, the hierarchical wrinkle shows great hydrophobicity and keeps the stretching property under 25%.
Einhäuser, Wolfgang; Nuthmann, Antje
2016-09-01
During natural scene viewing, humans typically attend and fixate selected locations for about 200-400 ms. Two variables characterize such "overt" attention: the probability of a location being fixated, and the fixation's duration. Both variables have been widely researched, but little is known about their relation. We use a two-step approach to investigate the relation between fixation probability and duration. In the first step, we use a large corpus of fixation data. We demonstrate that fixation probability (empirical salience) predicts fixation duration across different observers and tasks. Linear mixed-effects modeling shows that this relation is explained neither by joint dependencies on simple image features (luminance, contrast, edge density) nor by spatial biases (central bias). In the second step, we experimentally manipulate some of these features. We find that fixation probability from the corpus data still predicts fixation duration for this new set of experimental data. This holds even if stimuli are deprived of low-level images features, as long as higher level scene structure remains intact. Together, this shows a robust relation between fixation duration and probability, which does not depend on simple image features. Moreover, the study exemplifies the combination of empirical research on a large corpus of data with targeted experimental manipulations.
Kucukdisli, Murat; Ferenc, Dorota; Heinz, Marcel; Wiebe, Christine; Opatz, Till
2014-01-01
The cyclocondensation of enones with aminoacetonitrile furnishes 3,4-dihydro-2H-pyrrole-2-carbonitriles which can be readily converted to 2,4-disubstituted pyrroles by microwave-induced dehydrocyanation. Alternatively, oxidation of the intermediates produces 3,5-disubstituted pyrrole-2-carbonitriles.
Content Management: If You Build It Right, They Will Come
ERIC Educational Resources Information Center
Starkman, Neal
2006-01-01
According to James Robertson, the managing director of Step Two Designs, a content management consultancy, "A content management system supports the creation, management, distribution, publishing, and discovery of corporate information. It covers the complete lifecycle of the pages of one's site, from providing simple tools to create the…
Synthesis of Monodispersed Tantalum(V) oxide Nanospheres by an Ethylene Glycol Mediated Route
Tantalum(V) oxide (Ta2O5) nanospheres have been synthesized by a very simple ethylene glycol mediated route. The two-step process involves the formation of glycolate nanoparticles and their subsequent hydrolysis and calcination to generate the final Ta2O5 nanospheres. The synthes...
Simple Parametric Model for Airfoil Shape Description
NASA Astrophysics Data System (ADS)
Ziemkiewicz, David
2017-12-01
We show a simple, analytic equation describing a class of two-dimensional shapes well suited for representation of aircraft airfoil profiles. Our goal was to create a description characterized by a small number of parameters with easily understandable meaning, providing a tool to alter the shape with optimization procedures as well as manual tweaks by the designer. The generated shapes are well suited for numerical analysis with 2D flow solving software such as XFOIL.
How robotic-assisted surgery can decrease the risk of mucosal tear during Heller myotomy procedure?
Ballouhey, Quentin; Dib, Nabil; Binet, Aurélien; Carcauzon-Couvrat, Véronique; Clermidi, Pauline; Longis, Bernard; Lardy, Hubert; Languepin, Jane; Cros, Jérôme; Fourcade, Laurent
2017-06-01
We report the first description of robotic-assisted Heller myotomy in children. The purpose of this study was to improve the safety of Heller myotomy by demonstrating, in two adolescent patients, the contribution of the robot to the different steps of this procedure. Due to the robot's freedom of movement and three-dimensional vision, there was an improvement in the accuracy, a gain in the safety regarding different key-points, decreasing the risk of mucosal perforation associated with this procedure.
A volume-of-fluid method for simulation of compressible axisymmetric multi-material flow
NASA Astrophysics Data System (ADS)
de Niem, D.; Kührt, E.; Motschmann, U.
2007-02-01
A two-dimensional Eulerian hydrodynamic method for the numerical simulation of inviscid compressible axisymmetric multi-material flow in external force fields for the situation of pure fluids separated by macroscopic interfaces is presented. The method combines an implicit Lagrangian step with an explicit Eulerian advection step. Individual materials obey separate energy equations, fulfill general equations of state, and may possess different temperatures. Material volume is tracked using a piecewise linear volume-of-fluid method. An overshoot-free logically simple and economic material advection algorithm for cylinder coordinates is derived, in an algebraic formulation. New aspects arising in the case of more than two materials such as the material ordering strategy during transport are presented. One- and two-dimensional numerical examples are given.
ERIC Educational Resources Information Center
Steffen, Heather
2011-01-01
As the recession, budget cuts, endowment losses, and Republican governors gut university funding, campuses across the country have become host to occupations, union actions, and demonstrations. One can take steps to intimidate, alienate, and agitate a flock of graduate students. The author discusses steps that offer simple ways to rile up and…
USDA-ARS?s Scientific Manuscript database
Flour proteins from the US bread wheat Butte 86 were extracted in 0.5% SDS using a two-step procedure with and without sonication and further separated by size exclusion chromatography into monomeric and polymeric fractions. Proteins in each fraction were analyzed by quantitative two-dimensional gel...
Kuznetsova, Olga M; Tymofyeyev, Yevgen
2014-04-30
In open-label studies, partial predictability of permuted block randomization provides potential for selection bias. To lessen the selection bias in two-arm studies with equal allocation, a number of allocation procedures that limit the imbalance in treatment totals at a pre-specified level but do not require the exact balance at the ends of the blocks were developed. In studies with unequal allocation, however, the task of designing a randomization procedure that sets a pre-specified limit on imbalance in group totals is not resolved. Existing allocation procedures either do not preserve the allocation ratio at every allocation or do not include all allocation sequences that comply with the pre-specified imbalance threshold. Kuznetsova and Tymofyeyev described the brick tunnel randomization for studies with unequal allocation that preserves the allocation ratio at every step and, in the two-arm case, includes all sequences that satisfy the smallest possible imbalance threshold. This article introduces wide brick tunnel randomization for studies with unequal allocation that allows all allocation sequences with imbalance not exceeding any pre-specified threshold while preserving the allocation ratio at every step. In open-label studies, allowing a larger imbalance in treatment totals lowers selection bias because of the predictability of treatment assignments. The applications of the technique in two-arm and multi-arm open-label studies with unequal allocation are described. Copyright © 2013 John Wiley & Sons, Ltd.
Bonding effectiveness of self-etch adhesives to dentin after 24 h water storage.
Sarr, Mouhamed; Benoist, Fatou Leye; Bane, Khaly; Aidara, Adjaratou Wakha; Seck, Anta; Toure, Babacar
2018-01-01
This study evaluated the immediate bonding effectiveness of five self-etch adhesive systems bonded to dentin. The microtensile bond strength of five self-etch adhesives systems, including one two-step and four one-step self-etch adhesives to dentin, was measured. Human third molars had their superficial dentin surface exposed, after which a standardized smear layer was produced using a medium-grit diamond bur. The selected adhesives were applied according to their respective manufacturer's instructions for μTBS measurement after storage in water at 37°C for 24 h. The μTBS varied from 11.1 to 44.3 MPa; the highest bond strength was obtained with the two-step self-etch adhesive Clearfil SE Bond and the lowest with the one-step self-etch adhesive Adper Prompt L-Pop. Pretesting failures mainly occurring during sectioning with the slow-speed diamond saw were observed only with the one-step self-etch adhesive Adper Prompt L-Pop (4 out of 18). When bonded to dentin, the self-etch adhesives with simplified application procedures (one-step self-etch adhesives) still underperform as compared to the two-step self-etch adhesive Clearfil SE Bond.
Bonding effectiveness of self-etch adhesives to dentin after 24 h water storage
Sarr, Mouhamed; Benoist, Fatou Leye; Bane, Khaly; Aidara, Adjaratou Wakha; Seck, Anta; Toure, Babacar
2018-01-01
Purpose: This study evaluated the immediate bonding effectiveness of five self-etch adhesive systems bonded to dentin. Materials and Methods: The microtensile bond strength of five self-etch adhesives systems, including one two-step and four one-step self-etch adhesives to dentin, was measured. Human third molars had their superficial dentin surface exposed, after which a standardized smear layer was produced using a medium-grit diamond bur. The selected adhesives were applied according to their respective manufacturer's instructions for μTBS measurement after storage in water at 37°C for 24 h. Results: The μTBS varied from 11.1 to 44.3 MPa; the highest bond strength was obtained with the two-step self-etch adhesive Clearfil SE Bond and the lowest with the one-step self-etch adhesive Adper Prompt L-Pop. Pretesting failures mainly occurring during sectioning with the slow-speed diamond saw were observed only with the one-step self-etch adhesive Adper Prompt L-Pop (4 out of 18). Conclusions: When bonded to dentin, the self-etch adhesives with simplified application procedures (one-step self-etch adhesives) still underperform as compared to the two-step self-etch adhesive Clearfil SE Bond. PMID:29674814
Faraji, Hakim; Helalizadeh, Masoumeh; Kordi, Mohammad Reza
2018-01-01
A rapid, simple, and sensitive approach to the analysis of trihalomethanes (THMs) in swimming pool water samples has been developed. The main goal of this study was to overcome or to improve the shortcomings of conventional dispersive liquid-liquid microextraction (DLLME) and to maximize the realization of green analytical chemistry principles. The method involves a simple vortex-assisted microextraction step, in the absence of the dispersive solvent, followed by salting-out effect for the elimination of the centrifugation step. A bell-shaped device and a solidifiable solvent were used to simplify the extraction solvent collection after phase separation. Optimization of the independent variables was performed by using chemometric methods in three steps. The method was statistically validated based on authentic guidance documents. The completion time for extraction was less than 8 min, and the limits of detection were in the range between 4 and 72 ng L -1 . Using this method, good linearity and precision were achieved. The results of THMs determination in different real samples showed that in some cases the concentration of total THMs was more than threshold values of THMs determined by accredited healthcare organizations. This method indicated satisfactory analytical figures of merit. Graphical Abstract A novel green microextraction technique for overcoming the challenges of conventional DLLME. The proposed procedure complies with the principles of green/sustainable analytical chemistry, comprising decreasing the sample size, making easy automation of the process, reducing organic waste, diminishing energy consumption, replacing toxic reagents with safer reagents, and enhancing operator safety.
High throughput method to characterize acid-base properties of insoluble drug candidates in water.
Benito, D E; Acquaviva, A; Castells, C B; Gagliardi, L G
2018-05-30
In drug design experimental characterization of acidic groups in candidate molecules is one of the more important steps prior to the in-vivo studies. Potentiometry combined with Yasuda-Shedlovsky extrapolation is one of the more important strategy to study drug candidates with low solubility in water, although, it requires a large number of sequences to determine pK a values at different solvent-mixture compositions to, finally, obtain the pK a in water (pwwK a ) by extrapolation. We have recently proposed a method which requires only two sequences of additions to study the effect of organic solvent content in liquid chromatography mobile phases on the acidity of the buffer compounds usually dissolved in it along wide ranges of compositions. In this work we propose to apply this method to study thermodynamic pwwK a of drug candidates with low solubilities in pure water. Using methanol/water solvent mixtures we study six pharmaceutical drugs at 25 °C. Four of them: ibuprofen, salicylic acid, atenolol and labetalol, were chosen as members of carboxylic, amine and phenol families, respectively. Since these compounds have known pwwK a values, they were used to validate the procedure, the accuracy of Yasuda-Shedlovsky and other empirical models to fit the behaviors, and to obtain pwwK a by extrapolation. Finally, the method is applied to determine unknown thermodynamic pwwK a values of two pharmaceutical drugs: atorvastatin calcium and the two dissociation constants of ethambutol. The procedure proved to be simple, very fast and accurate in all of the studied cases. Copyright © 2018 Elsevier B.V. All rights reserved.
Direct Reconstruction of Two-Dimensional Currents in Thin Films from Magnetic-Field Measurements
NASA Astrophysics Data System (ADS)
Meltzer, Alexander Y.; Levin, Eitan; Zeldov, Eli
2017-12-01
An accurate determination of microscopic transport and magnetization currents is of central importance for the study of the electric properties of low-dimensional materials and interfaces, of superconducting thin films, and of electronic devices. Current distribution is usually derived from the measurement of the perpendicular component of the magnetic field above the surface of the sample, followed by numerical inversion of the Biot-Savart law. The inversion is commonly obtained by deriving the current stream function g , which is then differentiated in order to obtain the current distribution. However, this two-step procedure requires filtering at each step and, as a result, oversmooths the solution. To avoid this oversmoothing, we develop a direct procedure for inversion of the magnetic field that avoids use of the stream function. This approach provides enhanced accuracy of current reconstruction over a wide range of noise levels. We further introduce a reflection procedure that allows for the reconstruction of currents that cross the boundaries of the measurement window. The effectiveness of our approach is demonstrated by several numerical examples.
Direct Sensor Orientation of a Land-Based Mobile Mapping System
Rau, Jiann-Yeou; Habib, Ayman F.; Kersting, Ana P.; Chiang, Kai-Wei; Bang, Ki-In; Tseng, Yi-Hsing; Li, Yu-Hua
2011-01-01
A land-based mobile mapping system (MMS) is flexible and useful for the acquisition of road environment geospatial information. It integrates a set of imaging sensors and a position and orientation system (POS). The positioning quality of such systems is highly dependent on the accuracy of the utilized POS. This limitation is the major drawback due to the elevated cost associated with high-end GPS/INS units, particularly the inertial system. The potential accuracy of the direct sensor orientation depends on the architecture and quality of the GPS/INS integration process as well as the validity of the system calibration (i.e., calibration of the individual sensors as well as the system mounting parameters). In this paper, a novel single-step procedure using integrated sensor orientation with relative orientation constraint for the estimation of the mounting parameters is introduced. A comparative analysis between the proposed single-step and the traditional two-step procedure is carried out. Moreover, the estimated mounting parameters using the different methods are used in a direct geo-referencing procedure to evaluate their performance and the feasibility of the implemented system. Experimental results show that the proposed system using single-step system calibration method can achieve high 3D positioning accuracy. PMID:22164015
Laser-induced thermal ablation of cancerous cell organelles.
Letfullin, Renat R; Szatkowski, Scott A
2017-07-01
By exploiting the physical changes experienced by cancerous organelles, we investigate the feasibility of destroying cancerous cells by single and multipulse modes of laser heating. Our procedure consists of two primary steps: determining the normal and cancerous organelles optical properties and simulating the heating of all of the major organelles in the cell to find the treatment modes for the laser ablation of cancerous organelles without harming healthy cells. Our simulations show that the cancerous nucleus can be selectively heated to damaging temperatures, making this nucleus a feasible therapeutic particle and removing the need for nanoparticle injection. Because of the removal of this extra step, the procedure we propose is simpler and safer for the patient.
ERIC Educational Resources Information Center
Acar, Ebru Aktan; Çetin, Hilal
2017-01-01
The study features two basic steps. The first step of the research aims to develop a scale to measure the attitude of preschool teachers towards the Persona Dolls Approach and to verify its validity/reliability through a general survey. The cohort employed in the research was drawn from a pool of preschool teachers working in and around the cities…
Königsrainer, Ingmar; Zieker, Derek; Beckert, Stefan; Glatzle, Jörg; Schroeder, Torsten H; Heininger, Alexandra; Nadalin, Silvio; Königsrainer, Alfred
2010-08-01
Management of symptomatic pancreatic anastomotic insufficiency after pancreas head resection remains controversial. Completion pancreatectomy as one frequently performed option is associated with poor prognosis. During a 4-year period, a two-step strategy was applied in four consecutive patients suffering from pancreatic anastomotic insufficiency refractory to conservative management after a pancreas head resection. In the first step, sepsis was overbridged by meticulous debridement and resection of the pancreaticojejunostomy, leaving the biliary anastomosis untouched, and selective drainage of the pancreatic duct as well as the peripancreatic area. In the second step, after recovery, the procedure was completed with a novel pancreaticojejunostomy. The surgical procedure was completed in three patients after a mean of 164 (range: 112-213) days. One patient died from cardiac arrest 54 days after the reoperation with resolved abdominal sepsis. No pancreatic anastomotic insufficiency occurred after the new pancreaticojejunostomy had been performed. Three patients are alive and tumor-free with normal exocrine and endocrine pancreatic function after a mean follow-up of 20.3 (3-38) months following the definitive reconstruction. The two-step pancreas-preserving strategy can be used as an alternative to completion pancreatectomy for patients suffering from severe pancreatic anastomotic insufficiency.
Flu Diagnosis System Using Jaccard Index and Rough Set Approaches
NASA Astrophysics Data System (ADS)
Efendi, Riswan; Azah Samsudin, Noor; Mat Deris, Mustafa; Guan Ting, Yip
2018-04-01
Jaccard index and rough set approaches have been frequently implemented in decision support systems with various domain applications. Both approaches are appropriate to be considered for categorical data analysis. This paper presents the applications of sets operations for flu diagnosis systems based on two different approaches, such as, Jaccard index and rough set. These two different approaches are established using set operations concept, namely intersection and subset. The step-by-step procedure is demonstrated from each approach in diagnosing flu system. The similarity and dissimilarity indexes between conditional symptoms and decision are measured using Jaccard approach. Additionally, the rough set is used to build decision support rules. Moreover, the decision support rules are established using redundant data analysis and elimination of unclassified elements. A number data sets is considered to attempt the step-by-step procedure from each approach. The result has shown that rough set can be used to support Jaccard approaches in establishing decision support rules. Additionally, Jaccard index is better approach for investigating the worst condition of patients. While, the definitely and possibly patients with or without flu can be determined using rough set approach. The rules may improve the performance of medical diagnosis systems. Therefore, inexperienced doctors and patients are easier in preliminary flu diagnosis.
A simple test of association for contingency tables with multiple column responses.
Decady, Y J; Thomas, D R
2000-09-01
Loughin and Scherer (1998, Biometrics 54, 630-637) investigated tests of association in two-way tables when one of the categorical variables allows for multiple-category responses from individual respondents. Standard chi-squared tests are invalid in this case, and they developed a bootstrap test procedure that provides good control of test levels under the null hypothesis. This procedure and some others that have been proposed are computationally involved and are based on techniques that are relatively unfamiliar to many practitioners. In this paper, the methods introduced by Rao and Scott (1981, Journal of the American Statistical Association 76, 221-230) for analyzing complex survey data are used to develop a simple test based on a corrected chi-squared statistic.
NASA Astrophysics Data System (ADS)
Guo, Xiaowei; Chen, Mingyong; Zhu, Jianhua; Ma, Yanqin; Du, Jinglei; Guo, Yongkang; Du, Chunlei
2006-01-01
A novel method for the fabrication of continuous micro-optical components is presented in this paper. It employs a computer controlled digital-micromirror-device(DMD TM) as a switchable projection mask and silver-halide sensitized gelatin (SHSG) as recording material. By etching SHSG with enzyme solution, the micro-optical components with relief modulation can be generated through special processing procedures. The principles of etching SHSG with enzyme and theoretical analysis for deep etching are also discussed in detail, and the detailed quantitative experiments on the processing procedures are conducted to determine optimum technique parameters. A good linear relationship within a depth range of 4μm was experimentally obtained between exposure dose and relief depth. At last, the microlensarray with 256.8μm radius and 2.572μm depth was achieved. This method is simple, cheap and the aberration in processing procedures can be corrected in the step of designing mask, so it is a practical method to fabricate good continuous profile for low-volume production.
FDI based on Artificial Neural Network for Low-Voltage-Ride-Through in DFIG-based Wind Turbine.
Adouni, Amel; Chariag, Dhia; Diallo, Demba; Ben Hamed, Mouna; Sbita, Lassaâd
2016-09-01
As per modern electrical grid rules, Wind Turbine needs to operate continually even in presence severe grid faults as Low Voltage Ride Through (LVRT). Hence, a new LVRT Fault Detection and Identification (FDI) procedure has been developed to take the appropriate decision in order to develop the convenient control strategy. To obtain much better decision and enhanced FDI during grid fault, the proposed procedure is based on voltage indicators analysis using a new Artificial Neural Network architecture (ANN). In fact, two features are extracted (the amplitude and the angle phase). It is divided into two steps. The first is fault indicators generation and the second is indicators analysis for fault diagnosis. The first step is composed of six ANNs which are dedicated to describe the three phases of the grid (three amplitudes and three angle phases). Regarding to the second step, it is composed of a single ANN which analysis the indicators and generates a decision signal that describes the function mode (healthy or faulty). On other hand, the decision signal identifies the fault type. It allows distinguishing between the four faulty types. The diagnosis procedure is tested in simulation and experimental prototype. The obtained results confirm and approve its efficiency, rapidity, robustness and immunity to the noise and unknown inputs. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.