Secondary Ion Mass Spectrometry SIMS XI
NASA Astrophysics Data System (ADS)
Gillen, G.; Lareau, R.; Bennett, J.; Stevie, F.
2003-05-01
This volume contains 252 contributions presented as plenary, invited and contributed poster and oral presentations at the 11th International Conference on Secondary Ion Mass Spectrometry (SIMS XI) held at the Hilton Hotel, Walt Disney World Village, Orlando, Florida, 7 12 September, 1997. The book covers a diverse range of research, reflecting the rapid growth in advanced semiconductor characterization, ultra shallow depth profiling, TOF-SIMS and the new areas in which SIMS techniques are being used, for example in biological sciences and organic surface characterization. Papers are presented under the following categories: Isotopic SIMS Biological SIMS Semiconductor Characterization Techniques and Applications Ultra Shallow Depth Profiling Depth Profiling Fundamental/Modelling and Diffusion Sputter-Induced Topography Fundamentals of Molecular Desorption Organic Materials Practical TOF-SIMS Polyatomic Primary Ions Materials/Surface Analysis Postionization Instrumentation Geological SIMS Imaging Fundamentals of Sputtering Ion Formation and Cluster Formation Quantitative Analysis Environmental/Particle Characterization Related Techniques These proceedings provide an invaluable source of reference for both newcomers to the field and experienced SIMS users.
NanoSIMS Imaging Alternation Layers of a Leached SON68 Glass Via A FIB-made Wedged Crater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yi-Chung; Schreiber, Daniel K.; Neeway, James J.
2014-11-01
Currently, nuclear wastes are commonly immobilized into glasses because of their long-term durability. Exposure to water for long periods of time, however, will eventually corrode the waste form and is the leading potential avenue for radionuclide release into the environment. Because such slow processes cannot be experimentally tested, the prediction of release requires a thorough understanding the mechanisms governing glass corrosion. In addition, due to the exceptional durability of glass, much of the testing must be performed on high-surface-area powders. A technique that can provide accurate compositional profiles with very precise depth resolution for non-flat samples would be a majormore » benefit to the field. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling is an excellent tool that has long been used to examine corrosion layers of glass. The roughness of the buried corrosion layers, however, causes the corresponding SIMS depth profiles to exhibit erroneously wide interfaces. In this study, NanoSIMS was used to image the cross-section of the corrosion layers of a leached SON68 glass sample. A wedged crater was prepared by a focused ion beam (FIB) instrument to obtain a 5× improvement in depth resolution for NanoSIMS measurements. This increase in resolution allowed us to confirm that the breakdown of the silica glass network is further from the pristine glass than a second dissolution front for boron, another glass former. The existence of these two distinct interfaces, separated by only ~20 nm distance in depth, was not apparent by traditional ToF-SIMS depth profiling but has been confirmed also by atom probe tomography. This novel sample geometry will be a major benefit to efficient NanoSIMS sampling of irregular interfaces at the nanometer scale that would otherwise be obscured within ToF-SIMS depth profiles.« less
NASA Astrophysics Data System (ADS)
Pakhomov, Georgy L.; Drozdov, Mikhail N.; Travkin, Vlad V.; Bochkarev, Mikhail N.
2017-11-01
In this work we investigate the chemical composition of an archetypal thin-film organic device with the Ag/LiF cathode using the time-of-flight secondary ion mass spectrometry (ToF-SIMS) with depth profiling. The LiF cathode underlayer is partly decomposed because a significant amount of lithium is released into the bulk of the multilayer device. The released lithium diffuses all the way to the substrate, accumulating, as revealed by ToF-SIMS depth profiles, at the interfaces rather than uniformly doping the underlying layers. Particularly, the bottom anode becomes chemically modified.
Zappalà, G; Motta, V; Tuccitto, N; Vitale, S; Torrisi, A; Licciardello, A
2015-12-15
Secondary ion mass spectrometry (SIMS) with polyatomic primary ions provides a successful tool for molecular depth profiling of polymer systems, relevant in many technological applications. Widespread C60 sources, however, cause in some polymers extensive damage with loss of molecular information along depth. We study a method, based on the use of a radical scavenger, for inhibiting ion-beam-induced reactions causing sample damage. Layered polystyrene sulfonate and polyacrylic acid based polyelectrolyte films, behaving differently towards C60 beam-induced damage, were selected and prepared as model systems. They were depth profiled by means of time-of-flight (TOF)-SIMS in dual beam mode, using fullerene ions for sputtering. Nitric oxide was introduced into the analysis chamber as a radical scavenger. The effect of sample cooling combined with NO-dosing on the quality of depth profiles was explored. NO-dosing during C60-SIMS depth profiling of >1 micrometer-thick multilayered polyelectrolytes allows detection, along depth, of characteristic fragments from systems otherwise damaged by C60 bombardment, and increases sputtering yield by more than one order of magnitude. By contrast, NO has little influence on those layers that are well profiled with C60 alone. Such leveling effect, more pronounced at low temperature, leads to a dramatic improvement of profile quality, with a clear definition of interfaces. NO-dosing provides a tool for extending the applicability, in SIMS depth profiling, of the widely spread fullerene ion sources. In view of the acceptable erosion rates on inorganics, obtainable with C60, the method could be of relevance also in connection with the 3D-imaging of hybrid polymer/inorganic systems. Copyright © 2015 John Wiley & Sons, Ltd.
Influence of surface topography on depth profiles obtained with secondary-ion mass spectrometry
NASA Astrophysics Data System (ADS)
Walker, A. J.; Borchert, M. T.; Vriezema, C. J.; Zalm, P. C.
1990-11-01
Lithographically generated well-defined surface topography of submicron dimensions has been etched into silicon (100) previously implanted with 25 keV 11B to a fluence of 2×1014 atoms/cm2. The thus-obtained samples were depth profiled via secondary-ion mass spectrometry (SIMS). The boron concentration distributions measured were contrasted against those found on undisturbed flat parts of the target. From this intercomparison the otherwise trivial observation that surface topography causes profile distortion becomes suddenly alarming as an apparent improvement of depth resolution occurs. Scanning electron microscope images enable identification of the origin of this remarkable phenomenon. The present results imply that (i) the hitherto commonly accepted assumption in the interpretation of SIMS depth profiles that perceived gradients are never steeper than actual ones is subject to revision; (ii) it may prove very difficult, if not impossible, to construct SIMS equipment for reliable on-chip analysis of submicron details.
NASA Astrophysics Data System (ADS)
Chatterjee, Shiladitya; Singh, Bhupinder; Diwan, Anubhav; Lee, Zheng Rong; Engelhard, Mark H.; Terry, Jeff; Tolley, H. Dennis; Gallagher, Neal B.; Linford, Matthew R.
2018-03-01
X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are much used analytical techniques that provide information about the outermost atomic and molecular layers of materials. In this work, we discuss the application of multivariate spectral techniques, including principal component analysis (PCA) and multivariate curve resolution (MCR), to the analysis of XPS and ToF-SIMS depth profiles. Multivariate analyses often provide insight into data sets that is not easily obtained in a univariate fashion. Pattern recognition entropy (PRE), which has its roots in Shannon's information theory, is also introduced. This approach is not the same as the mutual information/entropy approaches sometimes used in data processing. A discussion of the theory of each technique is presented. PCA, MCR, and PRE are applied to four different data sets obtained from: a ToF-SIMS depth profile through ca. 100 nm of plasma polymerized C3F6 on Si, a ToF-SIMS depth profile through ca. 100 nm of plasma polymerized PNIPAM (poly (N-isopropylacrylamide)) on Si, an XPS depth profile through a film of SiO2 on Si, and an XPS depth profile through a film of Ta2O5 on Ta. PCA, MCR, and PRE reveal the presence of interfaces in the films, and often indicate that the first few scans in the depth profiles are different from those that follow. PRE and backward difference PRE provide this information in a straightforward fashion. Rises in the PRE signals at interfaces suggest greater complexity to the corresponding spectra. Results from PCA, especially for the higher principal components, were sometimes difficult to understand. MCR analyses were generally more interpretable.
NASA Astrophysics Data System (ADS)
Pacholski, Michaeleen L.
2004-06-01
Principal component analysis (PCA) has been successfully applied to time-of-flight secondary ion mass spectrometry (TOF-SIMS) spectra, images and depth profiles. Although SIMS spectral data sets can be small (in comparison to datasets typically discussed in literature from other analytical techniques such as gas or liquid chromatography), each spectrum has thousands of ions resulting in what can be a difficult comparison of samples. Analysis of industrially-derived samples means the identity of most surface species are unknown a priori and samples must be analyzed rapidly to satisfy customer demands. PCA enables rapid assessment of spectral differences (or lack there of) between samples and identification of chemically different areas on sample surfaces for images. Depth profile analysis helps define interfaces and identify low-level components in the system.
uleSIMS characterization of silver reference surfaces
NASA Astrophysics Data System (ADS)
Palitsin, V. V.; Dowsett, M. G.; Mata, B. Guzmán de la; Oloff, I. W.; Gibbons, R.
2006-07-01
Ultra low energy SIMS (uleSIMS) is a high sensitivity analytical technique that is normally used for ultra shallow profiling at a depth resolution of up to1 nm. This work describes the use of uleSIMS as both a spectroscopic and depth-profiling tool for the characterization of the early stages of corrosion formed on reference surfaces of silver. These samples are being developed to help with the characterization of tarnished surfaces in a cultural heritage context, and uleSIMS enables the tarnishing to be studied from its very earliest stages due to its high sensitivity (ppm-ppb) and surface specificity. We show that, uleSIMS can be used effectively to study the surface chemistry and aid the development of reference surfaces themselves. In particular, handling contaminants, surface dust, and residues from polishing are relatively easy to identify allowing them to be separated from the parts of the mass spectrum specific to the early stages of corrosion.
NASA Astrophysics Data System (ADS)
Reiche, Ina; Castaing, Jacques; Calligaro, Thomas; Salomon, Joseph; Aucouturier, Marc; Reinholz, Uwe; Weise, Hans-Peter
2006-08-01
Hydrogen is present in anhydrous materials as a result of their synthesis and of their environment during conservation. IBA provides techniques to measure H concentration depth profiles allowing to identify various aspects of the materials including the history of objects such as gemstones used in cultural heritage. A newly established ERDA set-up, using an external microbeam of alpha particles, has been developed to study hydrated near-surface layers in quartz and sapphire by non-destructive H depth profiling in different atmospheres. The samples were also analysed using resonant NRA and SIMS.
Kim, Min Jung; Lee, Jihye; Kim, Seon Hee; Kim, Haidong; Lee, Kang-Bong; Lee, Yeonhee
2015-10-01
Chalcopyrite Cu(In, Ga)Se2 (CIGS) thin films are well known as the next-generation solar cell materials notable for their high absorption coefficient for solar radiation, suitable band gap, and ability for deposition on flexible substrate materials, allowing the production of highly flexible and lightweight solar panels. To improve solar cell performances, a quantitative and depth-resolved elemental analysis of photovoltaic thin films is much needed. In this study, Cu(In, Ga)Se2 thin films were prepared on molybdenum back contacts deposited on soda-lime glass substrates via three-stage evaporation. Surface analyses via AES and SIMS were used to characterize the CIGS thin films and compare their depth profiles. We determined the average concentration of the matrix elements, Cu, In, Ga, and Se, using ICP-AES, XRF, and EPMA. We also obtained depth profiling results using TOF-SIMS, magnetic sector SIMS and AES, and APT, a sub-nanometer resolution characterization technique that enables three-dimensional elemental mapping. The SIMS technique, with its high detection limit and ability to obtain the profiles of elements in parallel, is a powerful tool for monitoring trace elements in CIGS thin films. To identify impurities in a CIGS layer, the distribution of trace elements was also observed according to depth by SIMS and APT.
Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter
Huang, Di; Hua, Xin; Xiu, Guang-Li; ...
2017-07-24
Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization, single particle analysis and depth profiling of PM is important for a better understanding of its formation processes and predicting its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, high spatial resolution chemical imaging and unique depth profiling capabilities. Recent research shows that SIMS has great potential in analyzing both surface and bulk chemical information of PM. In this review, we give amore » brief introduction of SIMS working principle and survey recent applications of SIMS in PM characterization. In particular, analyses from different types of PM sources by various SIMS techniques were discussed concerning their advantages and limitations. Finally, we propose, the future development and needs of SIMS in atmospheric aerosol measurement with a perspective in broader environmental sciences.« less
Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Di; Hua, Xin; Xiu, Guang-Li
Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization, single particle analysis and depth profiling of PM is important for a better understanding of its formation processes and predicting its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, high spatial resolution chemical imaging and unique depth profiling capabilities. Recent research shows that SIMS has great potential in analyzing both surface and bulk chemical information of PM. In this review, we give amore » brief introduction of SIMS working principle and survey recent applications of SIMS in PM characterization. In particular, analyses from different types of PM sources by various SIMS techniques were discussed concerning their advantages and limitations. Finally, we propose, the future development and needs of SIMS in atmospheric aerosol measurement with a perspective in broader environmental sciences.« less
Reducing the Matrix Effect in Organic Cluster SIMS Using Dynamic Reactive Ionization
NASA Astrophysics Data System (ADS)
Tian, Hua; Wucher, Andreas; Winograd, Nicholas
2016-12-01
Dynamic reactive ionization (DRI) utilizes a reactive molecule, HCl, which is doped into an Ar cluster projectile and activated to produce protons at the bombardment site on the cold sample surface with the presence of water. The methodology has been shown to enhance the ionization of protonated molecular ions and to reduce salt suppression in complex biomatrices. In this study, we further examine the possibility of obtaining improved quantitation with DRI during depth profiling of thin films. Using a trehalose film as a model system, we are able to define optimal DRI conditions for depth profiling. Next, the strategy is applied to a multilayer system consisting of the polymer antioxidants Irganox 1098 and 1010. These binary mixtures have demonstrated large matrix effects, making quantitative SIMS measurement not feasible. Systematic comparisons of depth profiling of this multilayer film between directly using GCIB, and under DRI conditions, show that the latter enhances protonated ions for both components by 4- to 15-fold, resulting in uniform depth profiling in positive ion mode and almost no matrix effect in negative ion mode. The methodology offers a new strategy to tackle the matrix effect and should lead to improved quantitative measurement using SIMS.
Escobar Galindo, Ramón; Gago, Raul; Duday, David; Palacio, Carlos
2010-04-01
An increasing amount of effort is currently being directed towards the development of new functionalized nanostructured materials (i.e., multilayers and nanocomposites). Using an appropriate combination of composition and microstructure, it is possible to optimize and tailor the final properties of the material to its final application. The analytical characterization of these new complex nanostructures requires high-resolution analytical techniques that are able to provide information about surface and depth composition at the nanometric level. In this work, we comparatively review the state of the art in four different depth-profiling characterization techniques: Rutherford backscattering spectroscopy (RBS), secondary ion mass spectrometry (SIMS), X-ray photoelectron spectroscopy (XPS) and glow discharge optical emission spectroscopy (GDOES). In addition, we predict future trends in these techniques regarding improvements in their depth resolutions. Subnanometric resolution can now be achieved in RBS using magnetic spectrometry systems. In SIMS, the use of rotating sample holders and oxygen flooding during analysis as well as the optimization of floating low-energy ion guns to lower the impact energy of the primary ions improves the depth resolution of the technique. Angle-resolved XPS provides a very powerful and nondestructive technique for obtaining depth profiling and chemical information within the range of a few monolayers. Finally, the application of mathematical tools (deconvolution algorithms and a depth-profiling model), pulsed sources and surface plasma cleaning procedures is expected to greatly improve GDOES depth resolution.
NASA Astrophysics Data System (ADS)
Ghezzi, F.; Caniello, R.; Giubertoni, D.; Bersani, M.; Hakola, A.; Mayer, M.; Rohde, V.; Anderle, M.; ASDEX Upgrade Team
2014-10-01
We present the results of a study where secondary ion mass spectrometry (SIMS) has been used to obtain depth profiles of deuterium concentration on plasma facing components of the first wall of the ASDEX Upgrade tokamak. The method uses primary and secondary standards to quantify the amount of deuterium retained. Samples of bulk graphite coated with tungsten or tantalum-doped tungsten are independently profiled with three different SIMS instruments. Their deuterium concentration profiles are compared showing good agreement. In order to assess the validity of the method, the integrated deuterium concentrations in the coatings given by one of the SIMS devices is compared with nuclear reaction analysis (NRA) data. Although in the case of tungsten the agreement between NRA and SIMS is satisfactory, for tantalum-doped tungsten samples the discrepancy is significant because of matrix effect induced by tantalum and differently eroded surface (W + Ta always exposed to plasma, W largely shadowed). A further comparison where the SIMS deuterium concentration is obtained by calibrating the measurements against NRA values is also presented. For the tungsten samples, where no Ta induced matrix effects are present, the two methods are almost equivalent.The results presented show the potential of the method provided that the standards used for the calibration reproduce faithfully the matrix nature of the samples.
Study of the Au-Cr bilayer system using X-ray reflectivity, GDOES, and ToF-SIMS
Jonnard, Philippe; Modi, Mohammed H.; Le Guen, Karine; ...
2018-04-17
Here, we study a Au (25 nm)/Cr (10 nm) bilayer system as a model of mirror for the soft X–ray energy range. The Au and Cr thin films are a few nanometer thick and are deposited on a float glass substrate. The sample is characterized by using 3 complementary techniques: soft X–ray reflectivity, glow discharge optical emission spectrometry (GDOES), and time–of–flight secondary ion mass spectroscopy (ToF–SIMS). Soft X–ray reflectivity provides information about the thickness and roughness of the different layers, while GDOES is used to obtain the elemental depth profile of the stack and ToF–SIMS to obtain the elemental andmore » chemical depth profiles. GDOES and ToF–SIMS have both a nanometer depth resolution. A coherent description of the bilayer stack is obtained through the combination of these techniques. It consists in 5 layers namely a surface contamination layer, a principal gold layer, a Au–Cr mixed layer, a Cr layer, and another contamination layer at the top of the substrate.« less
Study of the Au-Cr bilayer system using X-ray reflectivity, GDOES, and ToF-SIMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jonnard, Philippe; Modi, Mohammed H.; Le Guen, Karine
Here, we study a Au (25 nm)/Cr (10 nm) bilayer system as a model of mirror for the soft X–ray energy range. The Au and Cr thin films are a few nanometer thick and are deposited on a float glass substrate. The sample is characterized by using 3 complementary techniques: soft X–ray reflectivity, glow discharge optical emission spectrometry (GDOES), and time–of–flight secondary ion mass spectroscopy (ToF–SIMS). Soft X–ray reflectivity provides information about the thickness and roughness of the different layers, while GDOES is used to obtain the elemental depth profile of the stack and ToF–SIMS to obtain the elemental andmore » chemical depth profiles. GDOES and ToF–SIMS have both a nanometer depth resolution. A coherent description of the bilayer stack is obtained through the combination of these techniques. It consists in 5 layers namely a surface contamination layer, a principal gold layer, a Au–Cr mixed layer, a Cr layer, and another contamination layer at the top of the substrate.« less
Davidson, C M; Peters, N J; Britton, A; Brady, L; Gardiner, P H E; Lewis, B D
2004-01-01
Modern analytical techniques have been applied to investigate the nature of lead pipe corrosion products formed in pH adjusted, orthophosphate-treated, low alkalinity water, under supply conditions. Depth profiling and surface analysis have been carried out on pipe samples obtained from the water distribution system in Glasgow, Scotland, UK. X-ray diffraction spectrometry identified basic lead carbonate, lead oxide and lead phosphate as the principal components. Scanning electron microscopy/energy-dispersive x-ray spectrometry revealed the crystalline structure within the corrosion product and also showed spatial correlations existed between calcium, iron, lead, oxygen and phosphorus. Elemental profiling, conducted by means of secondary ion mass spectrometry (SIMS) and secondary neutrals mass spectrometry (SNMS) indicated that the corrosion product was not uniform with depth. However, no clear stratification was apparent. Indeed, counts obtained for carbonate, phosphate and oxide were well correlated within the depth range probed by SIMS. SNMS showed relationships existed between carbon, calcium, iron, and phosphorus within the bulk of the scale, as well as at the surface. SIMS imaging confirmed the relationship between calcium and lead and suggested there might also be an association between chloride and phosphorus.
TOF-SIMS Analysis of Red Color Inks of Writing and Printing Tools on Questioned Documents.
Lee, Jihye; Nam, Yun Sik; Min, Jisook; Lee, Kang-Bong; Lee, Yeonhee
2016-05-01
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a well-established surface technique that provides both elemental and molecular information from several monolayers of a sample surface while also allowing depth profiling or image mapping to be performed. Static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric, biological, archaeological, and forensic materials. In forensic investigation, the use of a minimal sample for the analysis is preferable. Although the TOF-SIMS technique is destructive, the probing beams have microsized diameters so that only small portion of the questioned sample is necessary for the analysis, leaving the rest available for other analyses. In this study, TOF-SIMS and attenuated total reflectance Fourier transform infrared (ATR-FTIR) were applied to the analysis of several different pen inks, red sealing inks, and printed patterns on paper. The overlapping areas of ballpoint pen writing, red seal stamping, and laser printing in a document were investigated to identify the sequence of recording. The sequence relations for various cases were determined from the TOF-SIMS mapping image and the depth profile. TOF-SIMS images were also used to investigate numbers or characters altered with two different red pens. TOF-SIMS was successfully used to determine the sequence of intersecting lines and the forged numbers on the paper. © 2016 American Academy of Forensic Sciences.
NASA Astrophysics Data System (ADS)
Oh, Won Jin; Jang, Jong Shik; Lee, Youn Seoung; Kim, Ansoon; Kim, Kyung Joong
2018-02-01
Quantitative analysis methods of multi-element alloy films were compared. The atomic fractions of Si1-xGex alloy films were measured by depth profiling analysis with secondary ion mass spectrometry (SIMS) and X-ray Photoelectron Spectroscopy (XPS). Intensity-to-composition conversion factor (ICF) was used as a mean to convert the intensities to compositions instead of the relative sensitivity factors. The ICFs were determined from a reference Si1-xGex alloy film by the conventional method, average intensity (AI) method and total number counting (TNC) method. In the case of SIMS, although the atomic fractions measured by oxygen ion beams were not quantitative due to severe matrix effect, the results by cesium ion beam were very quantitative. The quantitative analysis results by SIMS using MCs2+ ions are comparable to the results by XPS. In the case of XPS, the measurement uncertainty was highly improved by the AI method and TNC method.
NASA Astrophysics Data System (ADS)
Ignatova, V. A.; Möller, W.; Conard, T.; Vandervorst, W.; Gijbels, R.
2005-06-01
The TRIDYN collisional computer simulation has been modified to account for emission of ionic species and molecules during sputter depth profiling, by introducing a power law dependence of the ion yield as a function of the oxygen surface concentration and by modelling the sputtering of monoxide molecules. The results are compared to experimental data obtained with dual beam TOF SIMS depth profiling of ZrO2/SiO2/Si high-k dielectric stacks with thicknesses of the SiO2 interlayer of 0.5, 1, and 1.5 nm. Reasonable agreement between the experiment and the computer simulation is obtained for most of the experimental features, demonstrating the effects of ion-induced atomic relocation, i.e., atomic mixing and recoil implantation, and preferential sputtering. The depth scale of the obtained profiles is significantly distorted by recoil implantation and the depth-dependent ionization factor. A pronounced double-peak structure in the experimental profiles related to Zr is not explained by the computer simulation, and is attributed to ion-induced bond breaking and diffusion, followed by a decoration of the interfaces by either mobile Zr or O.
Kulkarni, Nagraj S.; Bruce Warmack, Robert J.; Radhakrishnan, Bala; ...
2014-09-23
Tracer diffusivities provide the most fundamental information on diffusion in materials and are the foundation of robust diffusion databases. Compared to traditional radiotracer techniques that utilize radioactive isotopes, the secondary ion mass spectrometry (SIMS) based thin-film technique for tracer diffusion is based on the use of enriched stable isotopes that can be accurately profiled using SIMS. Experimental procedures & techniques that are utilized for the measurement of tracer diffusion coefficients are presented for pure magnesium, which presents some unique challenges due to the ease of oxidation. The development of a modified Shewmon-Rhines diffusion capsule for annealing Mg and an ultra-highmore » vacuum (UHV) system for sputter deposition of Mg isotopes are discussed. Optimized conditions for accurate SIMS depth profiling in polycrystalline Mg are provided. An automated procedure for the correction of heat-up and cool-down times during tracer diffusion annealing is discussed. The non-linear fitting of a SIMS depth profile data using the thin film Gaussian solution to obtain the tracer diffusivity along with the background tracer concentration and tracer film thickness is discussed. An Arrhenius fit of the Mg self-diffusion data obtained using the low-temperature SIMS measurements from this study and the high-temperature radiotracer measurements of Shewmon and Rhines (1954) was found to be a good representation of both types of diffusion data that cover a broad range of temperatures between 250 - 627° C (523 900 K).« less
Depth Profiles of Mg, Si, and Zn Implants in GaN by Trace Element Accelerator Mass Spectrometry
NASA Astrophysics Data System (ADS)
Ravi Prasad, G. V.; Pelicon, P.; Mitchell, L. J.; McDaniel, F. D.
2003-08-01
GaN is one of the most promising electronic materials for applications requiring high-power, high frequencies, or high-temperatures as well as opto-electronics in the blue to ultraviolet spectral region. We have recently measured depth profiles of Mg, Si, and Zn implants in GaN substrates by the TEAMS particle counting method for both matrix and trace elements, using a gas ionization chamber. Trace Element Accelerator Mass Spectrometry (TEAMS) is a combination of Secondary Ion Mass Spectrometry (SIMS) and Accelerator Mass Spectrometry (AMS) to measure trace elements at ppb levels. Negative ions from a SIMS like source are injected into a tandem accelerator. Molecular interferences inherent with the SIMS method are eliminated in the TEAMS method. Negative ion currents are extremely low with GaN as neither gallium nor nitrogen readily forms negative ions making the depth profile measurements more difficult. The energies of the measured ions are in the range of 4-8 MeV. A careful selection of mass/charge ratios of the detected ions combined with energy-loss behavior of the ions in the ionization chamber eliminated molecular interferences.
NASA Astrophysics Data System (ADS)
Mahoney, Christine M.; Patwardhan, Dinesh V.; Ken McDermott, M.
2006-07-01
Secondary ion mass spectrometry (SIMS) employing an SF 5+ polyatomic primary ion source was utilized to analyze several materials commonly used in drug-eluting stents (DES). Poly(ethylene- co-vinyl acetate) (PEVA), poly(lactic- co-glycolic acid) (PLGA) and various poly(urethanes) were successfully depth profiled using SF 5+ bombardment. The resultant molecular depth profiles obtained from these polymeric films showed very little degradation in molecular signal as a function of increasing SF 5+ primary ion dose when experiments were performed at low temperatures (signal was maintained for doses up to ˜5 × 10 15 ions/cm 2). Temperature was determined to be an important parameter in both the success of the depth profiles and the mass spectral analysis of the polymers. In addition to the pristine polymer films, paclitaxel (drug released in Taxus™ stent) containing PLGA films were also characterized, where it was confirmed that both drug and polymer signals could be monitored as a function of depth at lower paclitaxel concentrations (10 wt%).
Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study.
Shard, Alexander G; Havelund, Rasmus; Spencer, Steve J; Gilmore, Ian S; Alexander, Morgan R; Angerer, Tina B; Aoyagi, Satoka; Barnes, Jean-Paul; Benayad, Anass; Bernasik, Andrzej; Ceccone, Giacomo; Counsell, Jonathan D P; Deeks, Christopher; Fletcher, John S; Graham, Daniel J; Heuser, Christian; Lee, Tae Geol; Marie, Camille; Marzec, Mateusz M; Mishra, Gautam; Rading, Derk; Renault, Olivier; Scurr, David J; Shon, Hyun Kyong; Spampinato, Valentina; Tian, Hua; Wang, Fuyi; Winograd, Nicholas; Wu, Kui; Wucher, Andreas; Zhou, Yufan; Zhu, Zihua; Cristaudo, Vanina; Poleunis, Claude
2015-08-20
We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-l-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray photoelectron spectroscopy (XPS) or time-of-flight secondary ion mass spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants' data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally, we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.
Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shard, A. G.; Havelund, Rasmus; Spencer, Steve J.
We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray Photoelectron Spectroscopy (XPS) or Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided withmore » the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.« less
Long-Term (4 mo) Oxygen Isotope Exchange Experiment between Zircon and Hydrothermal Fluid
NASA Astrophysics Data System (ADS)
Bindeman, I. N.; Schmitt, A. K.; Lundstrom, C.; Golledge, S.
2013-12-01
Knowing oxygen diffusivity in zircon has several critical applications: 1) establishing zircon stability and solubility in hot silica-saturated hydrothermal solutions; 2) deriving metamorphic and magmatic heating timescales from intra-crystal oxygen isotopic gradients; 3) assessing the survivability of oxygen isotopic signatures in Hadean zircons. We report results of a microanalytical investigation of an isotope exchange experiment using a cold-seal pressure apparatus at 850°C and 500 MPa over 4 months duration. Natural zircon, quartz and rutile were sealed with a silica-rich solution doped with 18-O, D, 7-Li and 10-B in a gold capsule. The diffusion length-scales were examined by depth profiling using time-of-flight (TOF) and high-sensitivity dynamic secondary ionization mass spectrometry (SIMS). Starting materials had distinct and homogeneous δ18O: zircon from Mesa Falls tuff of Yellowstone (+3.6‰), rutile from Karelia (-29‰), Bishop Tuff Quartz (+8.4‰), and δ18O doped water (+400‰). Starting material zircon showed invariant 18O/16O during depth profiling. After the 4 month experiment, rutile crystal surfaces displayed etching (100's of nm), while zircon exteriors lacked visible change. Quartz was completely dissolved and reprecipitated in a minor residue. Rutile developed ~2 μm long Fickian diffusion profiles largely consistent with the wet diffusion coefficients for rutile previously reported [1]. Surface U-Pb dating of zircon detected no significant Pb loss from the outermost ~300 nm of the crystal face and returned identical core-face ages. We performed δ18O depth profiling of zircon in two directions. First, forward profiles (crystal rim inwards) by dynamic SIMS (no surface treatment besides Au-coating; Cs+ beam of 20 kV impact energy) showed initially high and decreasing 18O/16O over ~130 nm; TOF-SIMS forward profiles using a 2 kV Cs+ sputter beam and 25 kV Bi3+ primary ions on uncoated zircon surfaces (cleaned for 2 min with HF) yielded decreasing 18O/16O over a similar length scale. These profile lengths are largely consistent with wet diffusion coefficient for zircon reported by [2]. In contrast, back-side depth profiling was conducted by dynamic SIMS on a 1 μm thick wafer cut from the zircon by FIB. No significant elevation in 18O/16O was detected when the surface layer was penetrated, consistent with dry diffusion coefficients of [2]. The results suggest that nm-scale SIMS surface analysis of isotope ratios is challenging. We are investigating if they can be critically affected by knock-on effects and/or continuous mixing of a very thin enriched surface layer during depth profiling in our and previous experiments. [1] Moore et al., 1998, Am. Min. 83, 700-711 [2] Watson and Cherniak, 1997, EPSL 148, 537-544
NASA Astrophysics Data System (ADS)
Hashiguchi, Minako; Sakaguchi, Isao; Adachi, Yutaka; Ohashi, Naoki
2016-10-01
Quantitative analyses of N and O ions in GaN thin films implanted with oxygen ions (16O+) were conducted by secondary ion mass spectrometry (SIMS). Positive (CsM+) and negative secondary ions extracted by Cs+ primary ion bombardment were analyzed for oxygen quantitative analysis. The oxygen depth profiles were obtained using two types of primary ion beams: a Gaussian-type beam and a broad spot beam. The oxygen peak concentrations in GaN samples were from 3.2 × 1019 to 7.0 × 1021 atoms/cm3. The depth profiles show equivalent depth resolutions in the two analyses. The intensity of negative oxygen ions was approximately two orders of magnitude higher than that of positive ions. In contrast, the O/N intensity ratio measured using CsM+ molecular ions was close to the calculated atomic density ratio, indicating that the SIMS depth profiling using CsM+ ions is much more effective for the measurements of O and N ions in heavy O-implanted GaN than that using negative ions.
Strong-field Photoionization of Sputtered Neutral Molecules for Molecular Depth Profiling
Willingham, D; Brenes, D. A.; Wucher, A
2009-01-01
Molecular depth profiles of an organic thin film of guanine vapor deposited onto a Ag substrate are obtained using a 40 keV C60 cluster ion beam in conjunction with time-of-flight secondary ion mass spectrometric (ToF-SIMS) detection. Strong-field, femtosecond photoionization of intact guanine molecules is used to probe the neutral component of the profile for direct comparison with the secondary ion component. The ability to simultaneously acquire secondary ions and photoionized neutral molecules reveals new fundamental information about the factors that influence the properties of the depth profile. Results show that there is an increased ionization probability for protonated molecular ions within the first 10 nm due to the generation of free protons within the sample. Moreover, there is a 50% increase in fragment ion signal relative to steady state values 25 nm before reaching the guanine/Ag interface as a result of interfacial chemical damage accumulation. An altered layer thickness of 20 nm is observed as a consequence of ion beam induced chemical mixing. In general, we show that the neutral component of a molecular depth profile using the strong-field photoionization technique can be used to elucidate the effects of variations in ionization probability on the yield of molecular ions as well as to aid in obtaining accurate information about depth dependent chemical composition that cannot be extracted from TOF-SIMS data alone. PMID:20495665
Quantitative SIMS depth profiling of diffusion barrier gate-oxynitride structures in TFT-LCDs.
Dreer, Sabine; Wilhartitz, Peter; Piplits, Kurt; Mayerhofer, Karl; Foisner, Johann; Hutter, Herbert
2004-06-01
Gate oxynitride structures of TFT-LCDs were investigated by SIMS, and successful solutions are demonstrated to overcome difficulties arising due to the charging effects of the multilayer systems, the matrix effect of the method, and the small pattern sizes of the samples. Because of the excellent reproducibility achieved by applying exponential relative sensitivity functions for quantitative analysis, minor differences in the barrier gate-oxynitride composition deposited on molybdenum capped aluminium-neodymium metallisation electrodes were determined between the centre and the edge of the TFT-LCD substrates. No differences were found for molybdenum-tungsten metallisations. Furthermore, at the edge of the glass substrates, aluminium, neodymium, and molybdenum SIMS depth profiles show an exponential trend. With TEM micrographs an inhomogeneous thickness of the molybdenum capping is revealed as the source of this effect, which influences the electrical behaviour of the device. The production process was improved after these results and the aging behaviour of TFT-LCDs was investigated in order to explain the change in control voltage occurring during the lifetime of the displays. SIMS and TEM show an enrichment of neodymium at the interface to the molybdenum layer, confirming good diffusion protection of the molybdenum barrier during accelerated aging. The reason for the shift of the control voltage was finally located by semi-quantitative depth profiling of the sodium diffusion originating from the glass substrate. Molybdenum-tungsten was a much better buffer for the highly-mobile charge carriers than aluminium-neodymium. Best results were achieved with PVD silicon oxynitride as diffusion barrier and gate insulator deposited on aluminium-neodymium metallisation layers.
ToF-SIMS Depth Profiling Of Insulating Samples, Interlaced Mode Or Non-interlaced Mode?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaoying; Jin, Ke; Zhang, Yanwen
2014-11-01
Dual beam depth profiling strategy has been widely adopted in ToF-SIMS depth profiling, in which two basic operation modes, interlaced mode and non-interlaced mode, are commonly used. Generally, interlaced mode is recommended for conductive or semi-conductive samples, whereas non-interlaced mode is recommended for insulating samples, where charge compensation can be an issue. Recent publications, however, show that the interlaced mode can be used effectively for glass depth profiling, despite the fact that glass is an insulator. In this study, we provide a simple guide for choosing between interlaced mode and non-interlaced mode for insulator depth profiling. Two representative cases aremore » presented: (1) depth profiling of a leached glass sample, and (2) depth profiling of a single crystal MgO sample. In brief, the interlaced mode should be attempted first, because (1) it may provide reasonable-quality data, and (2) it is time-saving for most cases, and (3) it introduces low H/C/O background. If data quality is the top priority and measurement time is flexible, non-interlaced mode is recommended because interlaced mode may suffer from low signal intensity and poor mass resolution. A big challenge is tracking trace H/C/O in a highly insulating sample (e.g., MgO), because non-interlaced mode may introduce strong H/C/O background but interlaced mode may suffer from low signal intensity. Meanwhile, a C or Au coating is found to be very effective to improve the signal intensity. Surprisingly, the best analyzing location is not on the C or Au coating, but at the edge (outside) of the coating.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smentkowski, Vincent S., E-mail: smentkow@ge.com
Changes in the oxidation state of an element can result in significant changes in the ionization efficiency and hence signal intensity during secondary ion mass spectrometry (SIMS) analysis; this is referred to as the SIMS matrix effect [Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. The SIMS matrix effect complicates quantitative analysis. Quantification of SIMS data requires the determination of relative sensitivity factors (RSFs), which can be used to convert the as measured intensity into concentration units [Secondarymore » Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis, edited by R. G. Wilson, F. A. Stevie, and C. W. Magee (Wiley, New York, 1990)]. In this manuscript, the authors report both: RSFs which were determined for quantification of B in Si and SiO{sub 2} matrices using a dual beam time of flight secondary ion mass spectrometry (ToF-SIMS) instrument and the protocol they are using to provide quantitative ToF-SIMS images and line scan traces. The authors also compare RSF values that were determined using oxygen and Ar ion beams for erosion, discuss the problems that can be encountered when bulk calibration samples are used to determine RSFs, and remind the reader that errors in molecular details of the matrix (density, volume, etc.) that are used to convert from atoms/cm{sup 3} to other concentration units will propagate into errors in the determined concentrations.« less
NASA Astrophysics Data System (ADS)
Beainy, Georges; Cerba, Tiphaine; Bassani, Franck; Martin, Mickaël; Baron, Thierry; Barnes, Jean-Paul
2018-05-01
Time of flight secondary ion mass spectrometry (ToF-SIMS) is a well-adapted analytical method for the chemical characterization of concentration profiles in layered or multilayered materials. However, under ion beam bombardment, initially smooth material surface becomes morphologically unstable. This leads to abnormal secondary ion yields and depth profile distortions. In this contribution, we explore the surface topography and roughening evolution induced by O2+ ion bombardment on GaSb/InAs multilayers. We demonstrate the formation of nanodots and ripples patterning according to the ion beam energy. Since the latter are undesirable for ToF-SIMS analysis, we managed to totally stop their growth by using simultaneously sample rotation and oxygen flooding. This unprecedented coupling between these two latter mechanisms leads to a significant enhancement in depth profiles resolution.
NASA Astrophysics Data System (ADS)
Krivec, Stefan; Detzel, Thomas; Buchmayr, Michael; Hutter, Herbert
2010-10-01
The detection of Na in insulating samples by means of time of flight-secondary ion mass spectrometry (ToF-SIMS) depth profiling has always been a challenge. In particular the use of O 2+ as sputter species causes a severe artifact in the Na depth distribution due to Na migration under the influence of an internal electrical filed. In this paper we address the influence of the sample temperature on this artifact. It is shown that the transport of Na is a dynamic process in concordance with the proceeding sputter front. Low temperatures mitigated the migration process by reducing the Na mobility in the target. In the course of this work two sample types have been investigated: (i) A Na doped PMMA layer, deposited on a thin SiO 2 film. Here, the incorporation behavior of Na into SiO 2 during depth profiling is demonstrated. (ii) Na implanted into a thin SiO 2 film. By this sample type the migration behavior could be examined when defects, originating from the implantation process, are present in the SiO 2 target. In addition, we propose an approach for the evaluation of an implanted Na profile, which is unaffected by the migration process.
Numerical investigation of depth profiling capabilities of helium and neon ions in ion microscopy
Rzeznik, Lukasz; Wirtz, Tom
2016-01-01
The analysis of polymers by secondary ion mass spectrometry (SIMS) has been a topic of interest for many years. In recent years, the primary ion species evolved from heavy monatomic ions to cluster and massive cluster primary ions in order to preserve a maximum of organic information. The progress in less-damaging sputtering goes along with a loss in lateral resolution for 2D and 3D imaging. By contrast the development of a mass spectrometer as an add-on tool for the helium ion microscope (HIM), which uses finely focussed He+ or Ne+ beams, allows for the analysis of secondary ions and small secondary cluster ions with unprecedented lateral resolution. Irradiation induced damage and depth profiling capabilities obtained with these light rare gas species have been far less investigated than ion species used classically in SIMS. In this paper we simulated the sputtering of multi-layered polymer samples using the BCA (binary collision approximation) code SD_TRIM_SP to study preferential sputtering and atomic mixing in such samples up to a fluence of 1018 ions/cm2. Results show that helium primary ions are completely inappropriate for depth profiling applications with this kind of sample materials while results for neon are similar to argon. The latter is commonly used as primary ion species in SIMS. For the two heavier species, layers separated by 10 nm can be distinguished for impact energies of a few keV. These results are encouraging for 3D imaging applications where lateral and depth information are of importance. PMID:28144525
NASA Astrophysics Data System (ADS)
Park, Eun Ji; Choi, Chang Min; Kim, Il Hee; Kim, Jung-Hwan; Lee, Gaehang; Jin, Jong Sung; Ganteför, Gerd; Kim, Young Dok; Choi, Myoung Choul
2018-01-01
Wet-chemically synthesized Au nanoparticles were deposited on Si wafer surfaces, and the secondary ions mass spectra (SIMS) from these samples were collected using Bi3+ with an energy of 30 keV as the primary ions. In the SIMS, Au cluster cations with a well-known, even-odd alteration pattern in the signal intensity were observed. We also performed depth profile SIMS analyses, i.e., etching the surface using an Ar gas cluster ion beam (GCIB), and a subsequent Bi3+ SIMS analysis was repetitively performed. Here, two different etching conditions (Ar1600 clusters of 10 keV energy or Ar1000 of 2.5 keV denoted as "harsh" or "soft" etching conditions, respectively) were used. Etching under harsh conditions induced emission of the Au-Si binary cluster cations in the SIMS spectra of the Bi3+ primary ions. The formation of binary cluster cations can be induced by either fragmentation of Au nanoparticles or alloying of Au and Si, increasing Au-Si coordination on the sample surface during harsh GCIB etching. Alternatively, use of the soft GCIB etching conditions resulted in exclusive emission of pure Au cluster cations with nearly no Au-Si cluster cation formation. Depth profile analyses of the Bi3+ SIMS combined with soft GCIB etching can be useful for studying the chemical environments of atoms at the surface without altering the original interface structure during etching.
Investigation of anodic TiO2 nanotube composition with high spatial resolution AES and ToF SIMS
NASA Astrophysics Data System (ADS)
Dronov, Alexey; Gavrilin, Ilya; Kirilenko, Elena; Dronova, Daria; Gavrilov, Sergey
2018-03-01
High resolution Scanning Auger Electron Spectroscopy (AES) and Time-of-Flight Secondary Ion Mass-Spectrometry (ToF SIMS) were used to investigate structure and elemental composition variation of both across an array of TiO2 nanotubes (NTs) and single tube of an array. The TiO2 NT array was grown by anodic oxidation of Ti foil in fluorine-containing ethylene glycol electrolyte. It was found that the studied anodic TiO2 nanotubes have a layered structure with rather sharp interfaces. The differences in AES depth profiling results of a single tube with the focused primary electron beam (point analysis) and over an area of 75 μm in diameter of a nanotube array with the defocused primary electron beam are discussed. Depth profiling by ToF SIMS was carried out over approximately the same size of a nanotube array to determine possible ionic fragments in the structure. The analysis results show that the combination of both mentioned methods is useful for a detailed analysis of nanostructures with complex morphology and multi-layered nature.
NASA Astrophysics Data System (ADS)
Monteleone, B. D.; van Soest, M. C.; Hodges, K. V.; Hervig, R.; Boyce, J. W.
2008-12-01
Conventional (U-Th)/He thermochronology utilizes single or multiple grain analyses of U- and Th-bearing minerals such as apatite and zircon and does not allow for assessment of spatial variation in concentration of He, U, or Th within individual crystals. As such, age calculation and interpretation require assumptions regarding 4He loss through alpha ejection, diffusive redistribution of 4He, and U and Th distribution as an initial condition for these processes. Although models have been developed to predict 4He diffusion parameters, correct for the effect of alpha ejection on calculated cooling ages, and account for the effect of U and Th zonation within apatite and zircon, measurements of 4He, U, and Th distribution have not been combined within a single crystal. We apply ArF excimer laser ablation, combined with noble gas mass spectrometry, to obtain depth profiles within apatite and zircon crystals in order to assess variations in 4He concentration with depth. Our initial results from pre-cut, pre-heated slabs of Durango apatite, each subjected to different T-t schedules, suggest a general agreement of 4He profiles with those predicted by theoretical diffusion models (Farley, 2000). Depth profiles through unpolished grains give reproducible alpha ejection profiles in Durango apatite that deviate from alpha ejection profiles predicted for ideal, homogenous crystals. SIMS depth profiling utilizes an O2 primary beam capable of sputtering tens of microns and measuring sub-micron resolution variation in [U], [Th], and [Sm]. Preliminary results suggest that sufficient [U] and [Th] zonation is present in Durango apatite to influence the form of the 4He alpha ejection profile. Future work will assess the influence of measured [U] and [Th] zonation on previously measured 4He depth profiles. Farley, K.A., 2000. Helium diffusion from apatite; general behavior as illustrated by Durango fluorapatite. J. Geophys. Res., B Solid Earth Planets 105 (2), 2903-2914.
Krecar, D; Rosner, M; Draxler, M; Bauer, P; Hutter, H
2006-01-01
The germanium concentration and the position and thickness of the quantum well in molecular beam epitaxy (MBE)-grown SiGe were quantitatively analyzed via low-energy Rutherford backscattering (RBS) and secondary ion mass spectrometry (SIMS). In these samples, the concentrations of Si and Ge were assumed to be constant, except for the quantum well, where the germanium concentration was lower. The thickness of the analyzed quantum well was about 12 nm and it was situated at a depth of about 60 nm below the surface. A dip showed up in the RBS spectra due to the lower germanium concentration in the quantum well, and this was evaluated. Good depth resolution was required in order to obtain quantitative results, and this was obtained by choosing a primary energy of 500 keV and a tilt angle of 51 degrees with respect to the surface normal. Quantitative information was deduced from the raw data by comparing it with SIMNRA simulated spectra. The SIMS measurements were performed with oxygen primary ions. Given the response function of the SIMS instrument (the SIMS depth profile of the germanium delta (delta) layer), and using the forward convolution (point-to-point convolution) model, it is possible to determine the germanium concentration and the thickness of the analyzed quantum well from the raw SIMS data. The aim of this work was to compare the results obtained via RBS and SIMS and to show their potential for use in the semiconductor and microelectronics industry. The detection of trace elements (here the doping element antimony) that could not be evaluated with RBS in low-energy mode is also demonstrated using SIMS instead.
Preliminary studies of the effect of thinning techniques over muon production profiles
NASA Astrophysics Data System (ADS)
Tomishiyo, G.; Souza, V.
2017-06-01
In the context of air shower simulations, thinning techniques are employed to reduce computational time and storage requirements. These techniques are tailored to preserve locally mean quantities during shower development, such as the average number of particles in a given atmosphere layer, and to not induce systematic shifts in shower observables, such as the depth of shower maximum. In this work we investigate thinning effects on the determination of the depth in which the shower has the maximum muon production {X}\\max μ -{sim}. We show preliminary results in which the thinning factor and maximum thinning weight might influence the determination of {X}\\max μ -{sim}
Modelling deuterium release during thermal desorption of D +-irradiated tungsten
NASA Astrophysics Data System (ADS)
Poon, M.; Haasz, A. A.; Davis, J. W.
2008-03-01
Thermal desorption profiles were modelled based on SIMS measurements of implantation profiles and using the multi-trap diffusion code TMAP7 [G.R. Longhurst, TMAP7: Tritium Migration Analysis Program, User Manual, Idaho National Laboratory, INEEL/EXT-04-02352 (2004)]. The thermal desorption profiles were the result of 500 eV/D + irradiations on single crystal tungsten at 300 and 500 K to fluences of 10 22-10 24 D +/m 2. SIMS depth profiling was performed after irradiation to obtain the distribution of trapped D within the top 60 nm of the surface. Thermal desorption spectroscopy (TDS) was performed subsequently to obtain desorption profiles and to extract the total trapped D inventory. The SIMS profiles were calibrated to give D concentrations. To account for the total trapped D inventory measured by TDS, SIMS depth distributions were used in the near-surface (surface to 30 nm), NRA measurements [V.Kh. Alimov, J. Roth, M. Mayer, J. Nucl. Mater. 337-339 (2005) 619] were used in the range 1-7 μm, and a linear drop in the D distribution was assumed in the intermediate sub-surface region (˜30 nm to 1 μm). Traps were assumed to be saturated so that the D distribution also represented the trap distribution. Three trap energies, 1.07 ± 0.03, 1.34 ± 0.03 and 2.1 ± 0.05 eV were required to model the 520, 640 and 900 K desorption peaks, respectively. The 1.34 and 1.07 eV traps correspond to trapping of a first and second D atom at a vacancy, respectively, while the 2.1 eV trap corresponds to atomic D trapping at a void. A fourth trap energy of 0.65 eV was used to fit the 400 K desorption peak observed by Quastel et al. [A.D. Quastel, J.W. Davis, A.A. Haasz, R.G. Macaulay-Newcombe, J. Nucl. Mater. 359 (2006) 8].
Development of nanotopography during SIMS characterization of thin films of Ge1-xSnx alloy
NASA Astrophysics Data System (ADS)
Secchi, M.; Demenev, E.; Colaux, J. L.; Giubertoni, D.; Dell'Anna, R.; Iacob, E.; Gwilliam, R. M.; Jeynes, C.; Bersani, M.
2015-11-01
This work presents a study of application of secondary ion mass spectrometry (SIMS) to measure tin concentration in Ge1-xSnx alloy with x higher than solid solubility ∼1%, i.e. well above the diluted regime where SIMS measurements usually provide the most reliable quantitative results. SIMS analysis was performed on Sn+ ion implanted Ge films, epitaxially deposited on Si, and on chemical vapor deposition deposited Ge0.93Sn0.07 alloy. Three SIMS conditions were investigated, varying primary beam ion species and secondary ion polarity keeping 1 keV impact energy. Best depth profile accuracy, best agreement with the fluences measured by Rutherford backscattering spectrometry, good detection limit (∼1 × 1017 at/cm3) and depth resolution (∼2 nm/decade) are achieved in Cs+/SnCs+ configuration. However, applied sputtering conditions (Cs+ 1 keV, 64° incidence vs. normal) induced an early formation of surface topography on the crater bottom resulting in significant variation of sputtering yield. Atomic force microscopy shows a peculiar topography developed on Ge: for oblique incidence, a topography consisting in a sequence of dots and ripples was observed on the crater bottom. This behavior is unusual for grazing incidence and has been observed to increase with the Cs+ fluence. Rotating sample during sputtering prevents this ripple formation and consequently improves the depth accuracy.
SIMS depth profiling of rubber-tyre cord bonding layers prepared using 64Zn depleted ZnO
NASA Astrophysics Data System (ADS)
Fulton, W. S.; Sykes, D. E.; Smith, G. C.
2006-07-01
Zinc oxide and copper/zinc sulphide layers are formed during vulcanisation and moulding of rubber to brass-coated steel tyre reinforcing cords. Previous studies have described how zinc diffuses through the rubber-brass interface to form zinc sulphide, and combines with oxygen to create zinc oxide during dezincification. The zinc is usually assumed to originate in the brass of the tyre cord, however, zinc oxide is also present in the rubber formulation. We reveal how zinc from these sources is distributed within the interfacial bonding layers, before and after heat and humidity ageing. Zinc oxide produced using 64Zn-isotope depleted zinc was mixed in the rubber formulation in place of the natural ZnO and the zinc isotope ratios within the interfacial layers were followed by secondary ion mass spectroscopy (SIMS) depth profiling. Variations in the relative ratios of the zinc isotopes during depth profiling were measured for unaged, heat-aged and humidity-aged wire samples and in each case a relatively large proportion of the zinc incorporated into the interfacial layer as zinc sulphide was shown to have originated from ZnO in the rubber compound.
Characterisation of nickel silicide thin films by spectroscopy and microscopy techniques.
Bhaskaran, M; Sriram, S; Holland, A S; Evans, P J
2009-01-01
This article discusses the formation and detailed materials characterisation of nickel silicide thin films. Nickel silicide thin films have been formed by thermally reacting electron beam evaporated thin films of nickel with silicon. The nickel silicide thin films have been analysed using Auger electron spectroscopy (AES) depth profiles, secondary ion mass spectrometry (SIMS), and Rutherford backscattering spectroscopy (RBS). The AES depth profile shows a uniform NiSi film, with a composition of 49-50% nickel and 51-50% silicon. No oxygen contamination either on the surface or at the silicide-silicon interface was observed. The SIMS depth profile confirms the existence of a uniform film, with no traces of oxygen contamination. RBS results indicate a nickel silicide layer of 114 nm, with the simulated spectra in close agreement with the experimental data. Atomic force microscopy and transmission electron microscopy have been used to study the morphology of the nickel silicide thin films. The average grain size and average surface roughness of these films was found to be 30-50 and 0.67 nm, respectively. The film surface has also been studied using Kikuchi patterns obtained by electron backscatter detection.
NASA Astrophysics Data System (ADS)
Goacher, Robyn Elizabeth
Secondary Ion Mass Spectrometry (SIMS) is an established method for the quantitative analysis of dopants in semiconductors. The quasi-parallel mass acquisition of Time-of-Flight SIMS, along with the development of polyatomic primary ions, have rapidly increased the use of SIMS for analysis of organic and biological specimens. However, the advantages and disadvantages of using cluster primary ions for quantitative analysis of inorganic materials are not clear. The research described in this dissertation investigates the consequences of using polyatomic primary ions for the analysis of inorganic compounds in ToF-SIMS. Furthermore, the diffusion of Mn in GaAs, which is important in Spintronic material applications such as spin injection, is also studied by quantitative ToF-SIMS depth profiling. In the first portion of this work, it was discovered that primary ion bombardment of pre-sputtered compound semiconductors GaAs and InP for the purpose of spectral analysis resulted in the formation of cluster secondary ions, as well as atomic secondary ions (Chapter 2). In particular, bombardment using a cluster primary ion such as Bi3q + or C60q+ resulted in higher yields of high-mass cluster secondary ions. These cluster secondary ions did not have bulk stoichiometry, "non-stoichiometric", in contrast to the paradigm of stoichiometric cluster ions generated from salts. This is attributed to the covalent bonding of the compound semiconductors, as well as to preferential sputtering. The utility of high-mass cluster secondary ions in depth profiling is also discussed. Relative sensitivity factors (RSFs) calculated for ion-implanted Fe and Mn samples in GaAs also exhibit differences based on whether monatomic or polyatomic primary ions are utilized (Chapter 3). These RSFs are important for the quantitative conversion of intensity to concentration. When Bi 32+ primary ions are used for analysis instead of Bi + primary ions, there is a significantly higher proportion of Mn and Fe ions present in the spectra, as referenced to the matrix species. The magnitude of this effect differs depending on the sputtering ion, Cs or C60. The use of C60cluster primary ions for depth profiling of GaAs is also investigated (Chapter 4). In particular, for quantitative depth profiling, parameters such as depth resolution, ion and sputter yields, and relative sensitivity factors are pertinent to profiling thin layered structures quantitatively and quickly. C60 sputtering is compared to Cs sputtering in all of these aspects. It is found that 10 keV C60+ is advantageous for the analysis of metals (such as Au contacts on Si) but that previously reported roughness problems prohibit successful analysis in Si. For Al delta layers and quantum wells in GaAs, C60 q+ sputtering induced very little roughness in the sample, and resulted in high ion yields and excellent signal-to-noise as compared to Cs+ sputtering. However, the depth resolution of C60 is at best equivalent to 1 keV Cs+ and does not extend into the sub 2-nm range. Furthermore, C60 sputtering results in significant carbon implantation. In the second portion of this work, quantitative ToF-SIMS depth profiling was used to evaluate the diffusion of Mn into GaAs. Samples were prepared by Molecular Beam Epitaxy in the department of Physics. Mn diffusion from MnAs was investigated first, and Mn diffusion from layered epitaxial structures of GaAs / Ga1-xMnxAs / GaAs was investigated second. Diffusion experiments were conducted by annealing portions of the samples in sealed glass ampoules at low temperatures (200-400°C). Different sputtering rates were measured for MnAs and GaAs and the measured depth profiles were corrected for these effects. RSFs measured for Mn ion-implanted standards were used to calibrate the intensity scale. For diffusion from MnAs, thin MnAs layers resulted in no measurable changes except in the surface transient. For thick MnAs layers, it was determined that substantial loss of As occurred at 400°C, resulting in severe sample roughening, which inhibited proper SIMS analysis. Results for the diffusion of Mn out of a thick buried layer of Ga1-xMnxAs show that annealing induces diffusion of Mn species from the Ga1-xMnxAs layer into the neighboring GaAs with an activation energy of 0.69+/-0.09 eV. This results in doping of the GaAs layer, which is detrimental to spin injection for Spintronics devices.
SIMS of organics—Advances in 2D and 3D imaging and future outlook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilmore, Ian S.
Secondary ion mass spectrometry (SIMS) has become a powerful technique for the label-free analysis of organics from cells to electronic devices. The development of cluster ion sources has revolutionized the field, increasing the sensitivity for organics by two or three orders of magnitude and for large clusters, such as C{sub 60} and argon clusters, allowing depth profiling of organics. The latter has provided the capability to generate stunning three dimensional images with depth resolutions of around 5 nm, simply unavailable by other techniques. Current state-of-the-art allows molecular images with a spatial resolution of around 500 nm to be achieved andmore » future developments are likely to progress into the sub-100 nm regime. This review is intended to bring those with some familiarity with SIMS up-to-date with the latest developments for organics, the fundamental principles that underpin this and define the future progress. State-of-the-art examples are showcased and signposts to more in-depth reviews about specific topics given for the specialist.« less
Willingham, D.; Brenes, D. A.; Winograd, N.; Wucher, A.
2010-01-01
Molecular depth profiles of model organic thin films were performed using a 40 keV C60+ cluster ion source in concert with TOF-SIMS. Strong-field photoionization of intact neutral molecules sputtered by 40 keV C60+ primary ions was used to analyze changes in the chemical environment of the guanine thin films as a function of ion fluence. Direct comparison of the secondary ion and neutral components of the molecular depth profiles yields valuable information about chemical damage accumulation as well as changes in the molecular ionization probability. An analytical protocol based on the erosion dynamics model is developed and evaluated using guanine and trehalose molecular secondary ion signals with and without comparable laser photoionization data. PMID:26269660
Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations
Akondi, Vyas; Dorronsoro, Carlos; Gambra, Enrique; Marcos, Susana
2017-01-01
Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed. PMID:28717577
In Situ Characterization of Hydrated Proteins in Water by SALVI and ToF-SIMS
Yu, Jiachao; Zhu, Zihua; Yu, Xiao-Ying
2016-01-01
This work demonstrates in situ characterization of protein biomolecules in the aqueous solution using the System for Analysis at the Liquid Vacuum Interface (SALVI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The fibronectin protein film was immobilized on the silicon nitride (SiN) membrane that forms the SALVI detection area. During ToF-SIMS analysis, three modes of analysis were conducted including high spatial resolution mass spectrometry, two-dimensional (2D) imaging, and depth profiling. Mass spectra were acquired in both positive and negative modes. Deionized water was also analyzed as a reference sample. Our results show that the fibronectin film in water has more distinct and stronger water cluster peaks compared to water alone. Characteristic peaks of amino acid fragments are also observable in the hydrated protein ToF-SIMS spectra. These results illustrate that protein molecule adsorption on a surface can be studied dynamically using SALVI and ToF-SIMS in the liquid environment for the first time. PMID:26966995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Jiachao; Zhou, Yufan; Hua, Xin
We demonstrate in situ chemical imaging of protein biomolecules in the aqueous solution using System for Analysis at the Liquid Vacuum Interface (SALVI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The fibronectin protein film was immobilized on the silicon nitride (SiN) membrane forming the SALVI detection area. During ToF-SIMS analysis, three modes of analysis were conducted including high spatial resolution mass spectra, two-dimensional (2D) imaging, and depth profiling. Mass spectra were acquired in both positive and negative modes. Deionized water was also analyzed as a reference sample. Our results show that fibronectin film in water has more distinct and strongermore » water cluster peaks compared to water alone. Characteristic peaks of amino acid fragments are also observable in the hydrated protein ToF-SIMS spectra. These results illustrate that protein molecule adsorption on a surface can be studied dynamically using SALVI and ToF-SIMS in the liquid environment.« less
A comparative study of surface waves inversion techniques at strong motion recording sites in Greece
Panagiotis C. Pelekis,; Savvaidis, Alexandros; Kayen, Robert E.; Vlachakis, Vasileios S.; Athanasopoulos, George A.
2015-01-01
Surface wave method was used for the estimation of Vs vs depth profile at 10 strong motion stations in Greece. The dispersion data were obtained by SASW method, utilizing a pair of electromechanical harmonic-wave source (shakers) or a random source (drop weight). In this study, three inversion techniques were used a) a recently proposed Simplified Inversion Method (SIM), b) an inversion technique based on a neighborhood algorithm (NA) which allows the incorporation of a priori information regarding the subsurface structure parameters, and c) Occam's inversion algorithm. For each site constant value of Poisson's ratio was assumed (ν=0.4) since the objective of the current study is the comparison of the three inversion schemes regardless the uncertainties resulting due to the lack of geotechnical data. A penalty function was introduced to quantify the deviations of the derived Vs profiles. The Vs models are compared as of Vs(z), Vs30 and EC8 soil category, in order to show the insignificance of the existing variations. The comparison results showed that the average variation of SIM profiles is 9% and 4.9% comparing with NA and Occam's profiles respectively whilst the average difference of Vs30 values obtained from SIM is 7.4% and 5.0% compared with NA and Occam's.
Depth resolution and preferential sputtering in depth profiling of sharp interfaces
NASA Astrophysics Data System (ADS)
Hofmann, S.; Han, Y. S.; Wang, J. Y.
2017-07-01
The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16-84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16-84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.
Secondary Ion Mass Spectrometry Imaging of Tissues, Cells, and Microbial Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderton, Christopher R.; Gamble, Lara J.
2016-03-01
Mass spectrometry imaging (MSI) techniques are increasingly being utilized within many biological fields, including medicine, pathology, microbial ecology, and more. Of the MSI methods available, secondary ion mass spectrometry (SIMS) offers the highest lateral resolution of any technique. Moreover, SIMS versatility in the number of different operating modes and types of mass spectrometers available has made it an increasing popular method for bio-related measurements. Here, we discuss SIMS ability to image tissues, single cells, and microbes with a particular emphasis on the types chemical and spatial information that can be ascertained by the different types of SIMS instruments and methods.more » The recently developed Fourier transform ion cyclotron resonance (FTICR) SIMS located at PNNL is capable of generating molecular maps of tissues with an unprecedented mass resolving power and mass accuracy, with respect to SIMS measurements. ToF-SIMS can generate chemical maps, where detection of small molecules and fragments can be acquired with an order of magnitude better lateral resolution than the FTICR-SIMS. Furthermore, many of commercially available ToF-SIMS instruments are capable of depth profiling measurements, offering the ability to attain three-dimensional information of one’s sample. The NanoSIMS instrument offers the highest lateral resolution of any MSI method available. In practice, NanoSIMS regularly achieves sub-100 nm resolution of atomic and diatomic secondary ions within biological samples. The strengths of the different SIMS methods are more and more being leveraged in both multimodal-imaging endeavors that use complementary MSI techniques as well with optical, fluorescence, and force microscopy methods.« less
SIMS studies of oxide growth on beta-NiAl
NASA Technical Reports Server (NTRS)
Mitchell, D. F.; Prescott, R.; Graham, M. J.; Doychak, J.
1992-01-01
This paper reports on a study of the growth of aluminum oxide on beta-NiAl at temperatures up to 1200 C. The scales have been formed in two-stage experiments using O2-16 and O2-18 gases, and the various isotopic species have been located by direct imaging using SIMS. Supplementary information on oxide morphologies and structures has been obtained by SEM. SIMS images and depth profiles indicate where oxidation has taken place predominantly by cation or anion diffusion at different stages of the growth process. The way in which the presence of small amounts of reactive elements can affect scale growth is also considered. These results help to provide an improved understanding of the mechanism of alumina scale formation, which is of benefit in the development of oxidation-resistant alloys and intermetallics for service at high temperatures.
Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Di; Hua, Xin; Xiu, Guang-Li
Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization of PM is important since the chemical heterogeneity between the surface and bulk may vary its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, capable of high spatial chemical imaging and depth profiling. Recent research shows that SIMS holds great potential in analyzing both surface and bulk chemical information of PM. In this review, we presented the working principal of SIMS in PMmore » characterization, summarized recent applications in PM analysis from different sources, discussed its advantages and limitations, and proposed the future development of this technique with a perspective in environmental sciences.« less
NASA Astrophysics Data System (ADS)
Liang, J. H.; Wang, S. C.
2007-08-01
The influence of substrate temperature on both the implantation and post-annealing characteristics of molecular-ion-implanted 5 × 1014 cm-2 77 keV BSi in silicon was investigated in terms of boron depth profiles and damage microstructures. The substrate temperatures under investigation consisted of room temperature (RT) and liquid nitrogen temperature (LT). Post-annealing treatments were performed using rapid thermal annealing (RTA) at 1050 °C for 25 s. Boron depth profiles and damage microstructures in both the as-implanted and as-annealed specimens were determined using secondary ion mass spectrometry (SIMS) and transmission electron microscopy (TEM), respectively. The as-implanted results revealed that, compared to the RT specimen, the LT specimen yields a shallower boron depth profile with a reduced tail into the bulk. An amorphous layer containing a smooth amorphous-to-crystalline (a/c) interface is evident in the LT specimen while just the opposite is true in the as-implanted RT one. The as-annealed results illustrated that the extension of the boron depth profile into the bulk via transient-enhanced diffusion (TED) in the LT specimen is less than it is in the RT one. Only residual defects are visible in the LT specimen while two clear bands of dislocation loops appear in the RT one.
Thin film characterization by laser interferometry combined with SIMS
NASA Astrophysics Data System (ADS)
Kempf, J.; Nonnenmacher, M.; Wagner, H. H.
1988-10-01
Thin film properties of technologically important materials (Si, GaAs, SiO2, WSix) have been measured by using a novel technique that combines secondary ion mass spectrometry (SIMS) and laser interferometry. The simultaneous measurement of optical phase and reflectance as well as SIMS species during ion sputtering yielded optical constants, sputtering rates and composition of thin films with high depth resolution. A model based on the principle of multiple reflection within a multilayer structure, which considered also transformation of the film composition in depth and time during sputtering, was fitted to the reflectance and phase data. This model was applied to reveal the transformation of silicon by sputtering with O{2/+} ions. Special attention was paid to the preequilibrium phase of the sputter process (amorphization, oxidation, and volume expansion). To demonstrate the analytical potential of our method the multilayer system WSix/poly-Si/SiO2/Si was investigated. The physical parameters and the stoichiometry of tungsten suicide were determined for annealed as well as deposited films. A highly sensitive technique that makes use of a Fabry-Perot etalon integrated with a Michelson type interferometer is proposed. This two-stage interferometer has the potential to profile a sample surface with subangstroem resolution.
Lee, Jihye; Kang, Min Hwa; Lee, Kang-Bong; Lee, Yeonhee
2013-05-15
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR) measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric.
NASA Astrophysics Data System (ADS)
Téllez Lozano, Helena; Druce, John; Cooper, Samuel J.; Kilner, John A.
2017-12-01
18O and 2H diffusion has been investigated at a temperature of 300 °C in the double perovskite material PrBaCo2O5+δ (PBCO) in flowing air containing 200 mbar of 2H216O. Secondary ion mass spectrometry (SIMS) depth profiling of exchanged ceramics has shown PBCO still retains significant oxygen diffusivity ( 1.3 × 10-11 cm2s-1) at this temperature and that the presence of water (2H216O), gives rise to an enhancement of the surface exchange rate over that in pure oxygen by a factor of 3. The 2H distribution, as inferred from the 2H216O- SIMS signal, shows an apparent depth profile which could be interpreted as 2H diffusion. However, examination of the 3-D distribution of the signal shows it to be nonhomogeneous and probably related to the presence of hydrated layers in the interior walls of pores and is not due to proton diffusion. This suggests that PBCO acts mainly as an oxygen ion mixed conductor when used in PCFC devices, although the presence of a small amount of protonic conductivity cannot be discounted in these materials.
Campaign 1.7 Pu Aging. Development of Time of Flight Secondary Ion Mass Spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venhaus, Thomas J.
2015-09-09
The first application of Time-of-Flight Secondary Ion Mass Spectroscopy (ToF-SIMS) to an aged plutonium surface has resulted in a rich set of surface chemistry data, as well as some unexpected results. FY15 was highlighted by not only the first mapping of hydrogen-containing features within the metal, but also a prove-in series of experiments using the system’s Sieverts Reaction Cell. These experiments involved successfully heating the sample to ~450 oC for nearly 24 hours while the sample was dosed several times with hydrogen, followed by an in situ ToF-SIMS analysis. During this year, the data allowed for better and more consistentmore » identification of the myriad peaks that result from the SIMS sputter process. In collaboration with the AWE (U.K), the system was also fully aligned for sputter depth profiling for future experiments.« less
Analysis and imaging of biocidal agrochemicals using ToF-SIMS.
Converso, Valerio; Fearn, Sarah; Ware, Ecaterina; McPhail, David S; Flemming, Anthony J; Bundy, Jacob G
2017-09-06
ToF-SIMS has been increasingly widely used in recent years to look at biological matrices, in particular for biomedical research, although there is still a lot of development needed to maximise the value of this technique in the life sciences. The main issue for biological matrices is the complexity of the mass spectra and therefore the difficulty to specifically and precisely detect analytes in the biological sample. Here we evaluated the use of ToF-SIMS in the agrochemical field, which remains a largely unexplored area for this technique. We profiled a large number of biocidal active ingredients (herbicides, fungicides, and insecticides); we then selected fludioxonil, a halogenated fungicide, as a model compound for more detailed study, including the effect of co-occurring biomolecules on detection limits. There was a wide range of sensitivity of the ToF-SIMS for the different active ingredient compounds, but fludioxonil was readily detected in real-world samples (wheat seeds coated with a commercial formulation). Fludioxonil did not penetrate the seed to any great depth, but was largely restricted to a layer coating the seed surface. ToF-SIMS has clear potential as a tool for not only detecting biocides in biological samples, but also mapping their distribution.
Three-dimensional imaging of cholesterol and sphingolipids within a Madin-Darby canine kidney cell
Yeager, Ashley N.; Weber, Peter K.; Kraft, Mary L.
2016-01-08
Metabolic stable isotope incorporation and secondary ion mass spectrometry(SIMS) depth profiling performed on a Cameca NanoSIMS 50 were used to image the 18O-cholesterol and 15N-sphingolipid distributions within a portion of a Madin-Darby canine kidney (MDCK) cell. Three-dimensional representations of the component-specific isotope distributions show clearly defined regions of 18O-cholesterol and 15N-sphingolipid enrichment that seem to be separate subcellular compartments. Furthermore, the low levels of nitrogen-containing secondary ions detected at the 18O-enriched regions suggest that these 18O-cholesterol-rich structures may be lipiddroplets, which have a core consisting of cholesterol esters and triacylglycerides.
Three-dimensional imaging of cholesterol and sphingolipids within a Madin-Darby canine kidney cell
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeager, Ashley N.; Weber, Peter K.; Kraft, Mary L.
Metabolic stable isotope incorporation and secondary ion mass spectrometry(SIMS) depth profiling performed on a Cameca NanoSIMS 50 were used to image the 18O-cholesterol and 15N-sphingolipid distributions within a portion of a Madin-Darby canine kidney (MDCK) cell. Three-dimensional representations of the component-specific isotope distributions show clearly defined regions of 18O-cholesterol and 15N-sphingolipid enrichment that seem to be separate subcellular compartments. Furthermore, the low levels of nitrogen-containing secondary ions detected at the 18O-enriched regions suggest that these 18O-cholesterol-rich structures may be lipiddroplets, which have a core consisting of cholesterol esters and triacylglycerides.
Caesium sputter ion source compatible with commercial SIMS instruments
NASA Astrophysics Data System (ADS)
Belykh, S. F.; Palitsin, V. V.; Veryovkin, I. V.; Kovarsky, A. P.; Chang, R. J. H.; Adriaens, A.; Dowsett, M.; Adams, F.
2006-07-01
A simple design for a caesium sputter cluster ion source compatible with commercially available secondary ion mass spectrometers is reported. This source has been tested with the Cameca IMS 4f instrument using the cluster Si n- and Cu n- ions, and will shortly be retrofitted to the floating low energy ion gun (FLIG) of the type used on the Cameca 4500/4550 quadruple instruments. Our experiments with surface characterization and depth profiling conducted to date demonstrate improvements of analytical capabilities of the SIMS instrument due to the non-additive enhancement of secondary ion emission and shorter ion ranges of polyatomic projectiles compared to atomic ions with the same impact energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hua, Xin; Marshall, Matthew J.; Xiong, Yijia
2015-05-01
A vacuum compatible microfluidic reactor, SALVI (System for Analysis at the Liquid Vacuum Interface) was employed for in situ chemical imaging of live biofilms using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Depth profiling by sputtering materials in sequential layers resulted in live biofilm spatial chemical mapping. 2D images were reconstructed to report the first 3D images of hydrated biofilm elucidating spatial and chemical heterogeneity. 2D image principal component analysis (PCA) was conducted among biofilms at different locations in the microchannel. Our approach directly visualized spatial and chemical heterogeneity within the living biofilm by dynamic liquid ToF-SIMS.
NASA Astrophysics Data System (ADS)
Bindeman, Ilya N.; Schmitt, Axel K.; Lundstrom, Craig C.; Hervig, Richard L.
2018-05-01
Stability of zircon in hydrothermal fluids and vanishingly slow rates of diffusion identify zircon as a reliable recorder of its formation conditions in recent and ancient rocks. Debate, however, persists on how rapidly oxygen and key trace elements (e.g., Li, B, Pb) diffuse when zircon is exposed to hot aqueous fluids. Here, we report results of a nano- to micrometer-scale investigation of isotopic exchange using natural zircon from Mesa Falls Tuff (Yellowstone) treated with quartz-saturated, isotopically (18O, D, 7Li, and 11B) labeled water with a nominal δ18O value of +450‰ over 4 months at 850°C and 50 MPa. Frontside (crystal rim inwards) δ18O depth profiling of zircon by magnetic sector SIMS shows initially high but decreasing 18O/16O over a 130 nm non-Fickian profile, with a decay length comparable to the signal from surficial Au coating deposited onto zircon. In contrast, backside (crystal interior outwards) depth profiling on a 2-3 µm thick wafer cut and thinned from treated zircon by focused ion beam (FIB) milling lacks any significant increase in 18O/16O during penetration of the original surface layer. Near-surface time-of-flight (TOF-SIMS) frontside profiles of uncoated zircon from 4-month and 1-day-long experiments as well as untreated zircons display similar enrichments of 18O over a distance of 20 nm. All frontside 18O profiles are here interpreted as transient surface signals from nm-thick surface enrichment or contamination unrelated to diffusion. Likewise, frontside depth profiling of H, Li, and B isotopes are similar for long- and short-duration experiments. Additionally, surface U-Pb dating of zircon from the 4-month experiment returned U-Pb ages by depth profiling with 1 µm penetration that were identical to untreated samples. Frontside and backside depth-profiling thus demonstrate that diffusive 18O enrichment in the presence of H2O is much slower than predicted from experiments in Watson and Cherniak (1997). Instead, intracrystalline exchange of oxygen between fluid and zircon in wet experimental conditions with excess silica occurred over length-scales equivalent to those predicted for dry diffusion. Oxygen diffusion coefficients even under wet conditions and elevated temperatures (850 °C) are <1-3×10-23 m2/sec, underscoring a virtual lack of oxygen diffusion and an outstanding survivability of zircons
Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques
Lee, Jihye; Kang, Min Hwa; Lee, Kang-Bong; Lee, Yeonhee
2013-01-01
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR) measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric. PMID:28809257
Liu, Yang; Lu, Caiyan; Twigg, Stephen; Ghaffari, Mehdi; Lin, Junhong; Winograd, Nicholas; Zhang, Q. M.
2013-01-01
The recent boom of energy storage and conversion devices, exploiting ionic liquids (ILs) to enhance the performance, requires an in-depth understanding of this new class of electrolytes in device operation conditions. One central question critical to device performance is how the mobile ions accumulate near charged electrodes. Here, we present the excess ion depth profiles of ILs in ionomer membrane actuators (Aquivion/1-butyl-2,3-dimethylimidazolium chloride (BMMI-Cl), 27 μm thick), characterized directly by Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) at liquid nitrogen temperature. Experimental results reveal that for the IL studied, cations and anions are accumulated at both electrodes. The large difference in the total volume occupied by the excess ions between the two electrodes cause the observed large bending actuation of the actuator. Hence we demonstrate that ToF-SIMS experiment provides great insights on the physics nature of ionic devices. PMID:23512124
Dual beam organic depth profiling using large argon cluster ion beams
Holzweber, M; Shard, AG; Jungnickel, H; Luch, A; Unger, WES
2014-01-01
Argon cluster sputtering of an organic multilayer reference material consisting of two organic components, 4,4′-bis[N-(1-naphthyl-1-)-N-phenyl- amino]-biphenyl (NPB) and aluminium tris-(8-hydroxyquinolate) (Alq3), materials commonly used in organic light-emitting diodes industry, was carried out using time-of-flight SIMS in dual beam mode. The sample used in this study consists of a ∽400-nm-thick NPB matrix with 3-nm marker layers of Alq3 at depth of ∽50, 100, 200 and 300 nm. Argon cluster sputtering provides a constant sputter yield throughout the depth profiles, and the sputter yield volumes and depth resolution are presented for Ar-cluster sizes of 630, 820, 1000, 1250 and 1660 atoms at a kinetic energy of 2.5 keV. The effect of cluster size in this material and over this range is shown to be negligible. © 2014 The Authors. Surface and Interface Analysis published by John Wiley & Sons Ltd. PMID:25892830
Téllez Lozano, Helena; Druce, John; Cooper, Samuel J.; Kilner, John A.
2017-01-01
Abstract 18O and 2H diffusion has been investigated at a temperature of 300 °C in the double perovskite material PrBaCo2O5+δ (PBCO) in flowing air containing 200 mbar of 2H2 16O. Secondary ion mass spectrometry (SIMS) depth profiling of exchanged ceramics has shown PBCO still retains significant oxygen diffusivity (~1.3 × 10−11 cm2s−1) at this temperature and that the presence of water (2H2 16O), gives rise to an enhancement of the surface exchange rate over that in pure oxygen by a factor of ~3. The 2H distribution, as inferred from the 2H2 16O− SIMS signal, shows an apparent depth profile which could be interpreted as 2H diffusion. However, examination of the 3-D distribution of the signal shows it to be nonhomogeneous and probably related to the presence of hydrated layers in the interior walls of pores and is not due to proton diffusion. This suggests that PBCO acts mainly as an oxygen ion mixed conductor when used in PCFC devices, although the presence of a small amount of protonic conductivity cannot be discounted in these materials. PMID:29383047
NASA Astrophysics Data System (ADS)
Popczun, Nicholas James
The work presented in this dissertation is focused on increasing the fundamental understanding of molecular secondary ion mass spectrometry (SIMS) ionization probability by measuring neutral molecule behavior with femtosecond, mid-infrared laser post-ionization (LPI). To accomplish this, a model system was designed with a homogeneous organic film comprised of coronene, a polycyclic hydrocarbon which provides substantial LPI signal. Careful consideration was given to signal lost to photofragmentation and undersampling of the sputtered plume that is contained within the extraction volume of the mass spectrometer. This study provided the first ionization probability for an organic compound measured directly by the relative secondary ions and sputtered neutral molecules using a strong-field ionization (SFI) ionization method. The measured value of ˜10-3 is near the upper limit of previous estimations of ionization probability for organic molecules. The measurement method was refined, and then applied to a homogeneous guanine film, which produces protonated secondary ions. This measurement found the probability of protonation to occur to be on the order of 10-3, although with less uncertainty than that of the coronene. Finally, molecular depth profiles were obtained for SIMS and LPI signals as a function of primary ion fluence to determine the effect of ionization probability on the depth resolution of chemical interfaces. The interfaces chosen were organic/inorganic interfaces to limit chemical mixing. It is shown that approaching the inorganic chemical interface can enhance or suppress the ionization probability for the organic molecule, which can lead to artificially sharpened or broadened depths, respectively. Overall, the research described in this dissertation provides new methods for measuring ionization efficiency in SIMS in both absolute and relative terms, and will inform both innovation in the technique, as well as increase understanding of depth-dependent experiments.
Dowlatshahi Pour, Masoumeh; Malmberg, Per; Ewing, Andrew
2016-05-01
We have characterized the use of sublimation to deposit matrix-assisted laser desorption/ionization (MALDI) matrices in secondary ion mass spectrometry (SIMS) analysis, i.e. matrix-enhanced SIMS (ME-SIMS), a common surface modification method to enhance sensitivity for larger molecules and to increase the production of intact molecular ions. We use sublimation to apply a thin layer of a conventional MALDI matrix, 2,5-dihydroxybenzoic acid (DHB), onto rat brain cerebellum tissue to show how this technique can be used to enhance molecular yields in SIMS while still retaining a lateral resolution around 2 μm and also to investigate the mechanism of this enhancement. The results here illustrate that cholesterol, which is a dominant lipid species in the brain, is decreased on the tissue surface after deposition of matrix, particularly in white matter. The decrease of cholesterol is followed by an increased ion yield of several other lipid species. Depth profiling of the sublimed rat brain reveals that the lipid species are de facto extracted by the DHB matrix and concentrated in the top most layers of the sublimed matrix. This extraction/concentration of lipids directly leads to an increase of higher mass lipid ion yield. It is also possible that the decrease of cholesterol decreases the potential suppression of ion yield caused by cholesterol migration to the tissue surface. This result provides us with significant insights into the possible mechanisms involved when using sublimation to deposit this matrix in ME-SIMS.
NASA Technical Reports Server (NTRS)
Vargas-Aburto, Carlos; Aron, Paul R.; Liff, Dale R.
1990-01-01
The design, construction, and initial use of an ion microprobe to carry out secondary ion mass spectrometry (SIMS) of solid samples is reported. The system is composed of a differentially pumped custom-made UHV (Ultra High Vacuum) chamber, a quadrupole mass spectrometer and a telefocus A-DIDA ion gun with the capability of producing beams of Cesium, as well as inert and reactive gases. The computer control and acquisition of the data were designed and implemented using a personal computer with plug-in boards, and external circuitry built as required to suit the system needs. The software is being developed by using a FORTH-like language. Initial tests aimed at characterizing the system, as well as preliminary surface and depth-profiling studies are presently underway.
Soufrière Hills Plagioclase: Postcards From the Edge.
NASA Astrophysics Data System (ADS)
Genareau, K.; Clarke, A.; Hervig, R.
2005-12-01
Secondary Ion Mass Spectrometry (SIMS) can provide sub-micron depth resolution for analyzing products of volcanic eruptions. SIMS was used to examine the outer rims of plagioclase phenocrysts derived from both explosive and effusive eruptions of the Soufrière Hills Volcano (SHV), Montserrat. Phenocrysts were separated from the host igneous rock by crushing with a mortar and pestle and then cleaned with a Branson Sonifier. A 12.5 kV O2+ primary ion beam was used to examine the variation in ten elements (Ca, Na, Si, Al, Ti, Zr, K, Fe, Sr, Li) through a crystal depth of 5-9 microns. Plagioclase crystals separated from explosively produced pumice clasts show increasing anorthite (An) content with depth into the crystal surface, starting at ~10% An at the surface and reaching a constant composition of ~45% An at 2-4 microns depth. According to experimentally determined estimates of plagioclase growth rates for the SHV magma (Couch et al. 2003; J. Petrology 44, 1477-1502), the 2-4 microns depth over which An changes corresponds to 1-7 hours of growth. Sr also shows a general increase with depth into the crystal. K shows a rapid decrease in abundance with depth. Fe shows more complex patterns that may indicate late-stage crystallization of magnetite. Plagioclase derived from exogenous dome samples also have surface compositions of ~10% An increasing with depth to ~30% An, but rather than plateau, the values begin to decrease again at 2-5 microns depth. This fluctuating abundance of An may reveal the presence of micron-scale decompression-induced growth zones that have not been previously documented due to limitations in the spatial resolution of conventional analytical techniques. Explosive and effusive samples exhibit conflicting Li trends. The explosively derived plagioclase have elevated surface Li concentrations while the dome derived plagioclase have low surface Li concentrations. These differing trends may provide evidence of closed system vs. open system degassing as a function of eruptive style. Geochemical analyses of igneous phenocrysts using the SIMS depth-profiling technique can be used to constrain the style of magma decompression and eruption. Additional analyses are currently being performed on an expanded suite of samples in order to confirm these results and to relate crystal-edge chemistry to other parameters such as quench pressure and degree of magma degassing.
Davies, Sarah K; Fearn, Sarah; Allsopp, Luke P; Harrison, Freya; Ware, Ecaterina; Diggle, Stephen P; Filloux, Alain; McPhail, David S; Bundy, Jacob G
2017-01-01
Bacterial biofilms are groups of bacteria that exist within a self-produced extracellular matrix, adhering to each other and usually to a surface. They grow on medical equipment and inserts such as catheters and are responsible for many persistent infections throughout the body, as they can have high resistance to many antimicrobials. Pseudomonas aeruginosa is an opportunistic pathogen that can cause both acute and chronic infections and is used as a model for research into biofilms. Direct biochemical methods of imaging of molecules in bacterial biofilms are of high value in gaining a better understanding of the fundamental biology of biofilms and biochemical gradients within them. Time of flight-secondary-ion mass spectrometry (TOF-SIMS) is one approach, which combines relatively high spatial resolution and sensitivity and can perform depth profiling analysis. It has been used to analyze bacterial biofilms but has not yet been used to study the distribution of antimicrobials (including antibiotics and the antimicrobial metal gallium) within biofilms. Here we compared two methods of imaging of the interior structure of P. aeruginosa in biological samples using TOF-SIMS, looking at both antimicrobials and endogenous biochemicals: cryosectioning of tissue samples and depth profiling to give pseudo-three-dimensional (pseudo-3D) images. The sample types included both simple biofilms grown on glass slides and bacteria growing in tissues in an ex vivo pig lung model. The two techniques for the 3D imaging of biofilms are potentially valuable complementary tools for analyzing bacterial infection. IMPORTANCE Modern analytical techniques are becoming increasingly important in the life sciences; imaging mass spectrometry offers the opportunity to gain unprecedented amounts of information on the distribution of chemicals in samples-both xenobiotics and endogenous compounds. In particular, simultaneous imaging of antibiotics (and other antimicrobial compounds) and bacterium-derived metabolites in complex biological samples could be very important in the future for helping to understand how sample matrices impact the survival of bacteria under antibiotic challenge. We have shown that an imaging mass spectrometric technique, TOF-SIMS, will be potentially extremely valuable for this kind of research in the future.
Characterization of Arsenic Contamination on Rust from Ton Containers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary S. Groenewold; Recep Avci; Robert V. Fox
The speciation and spatial distribution of arsenic on rusted steel surfaces affects both measurement and removal approaches. The chemistry of arsenic residing in the rust of ton containers that held the chemical warfare agents bis(2-chloroethyl)sulfide (sulfur mustard) and 2-chlorovinyldichloroarsine (Lewisite) is of particular interest, because while the agents have been decontaminated, residual arsenic could pose a health or environmental risk. The chemistry and distribution of arsenic in rust samples was probed using imaging secondary ion mass spectrometry (SIMS), X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy, and scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDX). Arsenic in the +3 and or +5more » oxidation state is homogeneously distributed at the very top-most layer of the rust samples, and is intimately associated with iron. Sputter depth profiling followed by SIMS and XPS shows As at a depth of several nm, in some cases in a reduced form. The SEM/EDX experiments show that As is present at a depth of several microns, but is inhomogeneously distributed; most locations contained oxidized As at concentrations of a few percent, however several locations showed very high As in a metallic form. These results indicate that the rust material must be removed if the steel containers are to be cleared of arsenic.« less
Körsgen, Martin; Pelster, Andreas; Dreisewerd, Klaus; Arlinghaus, Heinrich F
2016-02-01
The analytical sensitivity in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is largely affected by the specific analyte-matrix interaction, in particular by the possible incorporation of the analytes into crystalline MALDI matrices. Here we used time-of-flight secondary ion mass spectrometry (ToF-SIMS) to visualize the incorporation of three peptides with different hydrophobicities, bradykinin, Substance P, and vasopressin, into two classic MALDI matrices, 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (HCCA). For depth profiling, an Ar cluster ion beam was used to gradually sputter through the matrix crystals without causing significant degradation of matrix or biomolecules. A pulsed Bi3 ion cluster beam was used to image the lateral analyte distribution in the center of the sputter crater. Using this dual beam technique, the 3D distribution of the analytes and spatial segregation effects within the matrix crystals were imaged with sub-μm resolution. The technique could in the future enable matrix-enhanced (ME)-ToF-SIMS imaging of peptides in tissue slices at ultra-high resolution. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Körsgen, Martin; Pelster, Andreas; Dreisewerd, Klaus; Arlinghaus, Heinrich F.
2016-02-01
The analytical sensitivity in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is largely affected by the specific analyte-matrix interaction, in particular by the possible incorporation of the analytes into crystalline MALDI matrices. Here we used time-of-flight secondary ion mass spectrometry (ToF-SIMS) to visualize the incorporation of three peptides with different hydrophobicities, bradykinin, Substance P, and vasopressin, into two classic MALDI matrices, 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (HCCA). For depth profiling, an Ar cluster ion beam was used to gradually sputter through the matrix crystals without causing significant degradation of matrix or biomolecules. A pulsed Bi3 ion cluster beam was used to image the lateral analyte distribution in the center of the sputter crater. Using this dual beam technique, the 3D distribution of the analytes and spatial segregation effects within the matrix crystals were imaged with sub-μm resolution. The technique could in the future enable matrix-enhanced (ME)-ToF-SIMS imaging of peptides in tissue slices at ultra-high resolution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hua, Xin; Yu, Xiao-Ying; Wang, Zhaoying
The first results of using a novel single channel microfluidic reactor to enable Shewanella biofilm growth and in situ characterization using time-of-flight secondary ion mass spectrometry (ToF-SIMS) in the hydrated environment are presented. The new microfluidic interface allows direct probing of the liquid surface using ToF-SIMS, a vacuum surface technique. The detection window is an aperture of 2 m in diameter on a thin silicon nitride (SiN) membrane and it allows direct detection of the liquid surface. Surface tension of the liquid flowing inside the microchannel holds the liquid within the aperture. ToF-SIMS depth profiling was used to drill throughmore » the SiN membrane and the biofilm grown on the substrate. In situ 2D imaging of the biofilm in hydrated state was acquired, providing spatial distribution of the chemical compounds in the biofilm system. This data was compared with a medium filled microfluidic reactor devoid of biofilm and dried biofilm samples deposited on clean silicon wafers. Principle Component Analysis (PCA) was used to investigate these observations. Our results show that imaging biofilms in the hydrated environment using ToF-SIMS is possible using the unique microfluidic reactor. Moreover, characteristic biofilm fatty acids fragments were observed in the hydrated biofilm grown in the microfluidic channel, illustrating the advantage of imaging biofilm in its native environment.« less
NASA Astrophysics Data System (ADS)
McLean, W.; Colmenares, C. A.; Smith, R. L.; Somorjai, G. A.
1982-01-01
The adsorption of O2, CO, and CO2 on the thorium (111) crystal face and on polycrystalline α-uranium has been investigated by x-ray photoelectron spectroscopy, Auger electron spectroscopy (AES), and secondary-ion mass spectroscopy (SIMS) at 300 K. Oxygen adsorption on both metals resulted in the formation of the metal dioxide. CO and CO2 adsorption on Th(111) produced species derived from atomic carbon and oxygen; the presence of molecular CO was also detected. Only atomic carbon and oxygen were observed on uranium. Elemental depth profiles by AES and SIMS indicated that the carbon produced by the dissociation of CO or CO2 diffused into the bulk of the metals to form a carbide, while the oxygen remained on their surfaces as an oxide.
Impurity measurements in semiconductor materials using trace element accelerator mass spectrometry
NASA Astrophysics Data System (ADS)
McDaniel, F. D.; Datar, S. A.; Nigam, M.; Ravi Prasad, G. V.
2002-05-01
Accelerator mass spectrometry (AMS) is commonly used to determine the abundance ratios of long-lived isotopes such as 10B, 14C, 36Cl, 129I, etc. to their stable counterparts at levels as low as 10 -16. Secondary ion mass spectrometry (SIMS) is routinely used to determine impurity levels in materials by depth profiling techniques. Trace-element accelerator mass spectrometry (TEAMS) is a combination of AMS and SIMS, presently being used at the University of North Texas, for high-sensitivity (ppb) impurity analyses of stable isotopes in semiconductor materials. The molecular break-up characteristics of AMS are used with TEAMS to remove the molecular interferences present in SIMS. Measurements made with different substrate/impurity combinations demonstrate that TEAMS has higher sensitivity for many elements than other techniques such as SIMS and can assist with materials characterization issues. For example, measurements of implanted As in the presence of Ge in Ge xSi 1- x/Si is difficult with SIMS because of molecular interferences from 74GeH, 29Si 30Si 16O, etc. With TEAMS, the molecular interferences are removed and higher sensitivities are obtained. Measured substrates include Si, SiGe, CoSi 2, GaAs and GaN. Measured impurities include B, N, F, Mg, P, Cl, Cr, Fe, Ni, Co, Cu, Zn, Ge, As, Se, Mo, Sn and Sb. A number of measurements will be presented to illustrate the range and power of TEAMS.
NASA Astrophysics Data System (ADS)
Appawu, Jennifer A. M.
This thesis project consisted of three main components that were connected by roots in chemical analysis for studies in tissue engineering. The first part focused on characterizing the structural parameters of synthetic cross-linked poly (2-hydroxyethyl methacrylate) (Poly(HEMA) hydrogel membranes to determine optimal formulations for clinical studies. Poly(HEMA) membranes were loaded with Keratincocyte Growth Factor (KGF) for controlled release studies. Protein loading and release kinetics were determined with fluorescence spectroscopy. The spatial distribution of a protein in the membrane was determined using Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS). The last part of the project focused on determining the biological effects of the polymer membranes in-vitro with a model cell line and a pilot in-vivo animal study. Based on the components completed in this project, five chapters are included in this dissertation document and are summarized below. A new protocol was developed using fluorescence spectroscopy that measured the rate of protein diffusion into cross-linked polymer membranes by measuring the change in the fluorescence intensity of the protein solution. This technique was also able to detect a conformational change that occurs within protein when KGF was imbibed within these cross-linked polymer membranes. ToF-SIMS chemical imaging and 3D depth profiling was used to determine the spatial distribution of KGF protein in frozen-hydrated HEMA hydrogel membranes. The 3D depth profiles showed that the KGF protein was aggregated in bright spots that indicated that KGF was not spatially homogenous on the surface and through the depth profiles. 3D depth profiles of the membranes studied at various times during release studies show that areas with aggregated proteins were retained during release, and at times with maximum release. The interpretation of the bright regions is that the KGf protein interacted with the cross-linked network of the hydrogel membranes, making it not available for release. The in-vitro biological experiments with the HaCaT cell line showed that the HEMA hydrogels were capable of sustaining cell viability, proliferation, and adhesion through cell adhesion and wounding experiments. The pilot in-vivo animal study also revealed that KGF protein had retained its pharmacological activity. The study also showed that the KGF protein enhanced the rate of wound closure.
NASA Astrophysics Data System (ADS)
Burnham, Shawn D.; Thomas, Edward W.; Doolittle, W. Alan
2006-12-01
A characterization technique is discussed that allows quantitative optimization of doping in epitaxially grown semiconductors. This technique uses relative changes in the host atom secondary ion (HASI) energy distribution from secondary ion mass spectroscopy (SIMS) to indicate relative changes in conductivity of the material. Since SIMS is a destructive process due to sputtering through a film, a depth profile of the energy distribution of sputtered HASIs in a matrix will contain information on the conductivity of the layers of the film as a function of depth. This process is demonstrated with Mg-doped GaN, with the Mg flux slowly increased through the film. Three distinct regions of conductivity were observed: one with Mg concentration high enough to cause compensation and thus high resistivity, a second with moderate Mg concentration and low resistivity, and a third with little to no Mg doping, causing high resistivity due to the lack of free carriers. During SIMS analysis of the first region, the energy distributions of sputtered Ga HASIs were fairly uniform and unchanging for a Mg flux above the saturation, or compensation, limit. For the second region, the Ga HASI energy distributions shifted and went through a region of inconsistent energy distributions for Mg flux slightly below the critical flux for saturation, or compensation. Finally, for the third region, the Ga HASI energy distributions then settled back into another fairly unchanging, uniform pattern. These three distinct regions were analyzed further through growth of Mg-doped step profiles and bulk growth of material at representative Mg fluxes. The materials grown at the two unchanging, uniform regions of the energy distributions yielded highly resistive material due to too high of Mg concentration and low to no Mg concentration, respectively. However, material grown in the transient energy distribution region with Mg concentration between that of the two highly resistive regions yielded low resistivity (0.59Ωcm) and highly p-type (1.2×1018cm-3 holes) Mg-doped GaN.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaoying; Liu, Bingwen; Zhao, Evan
For the first time, the use of an argon cluster ion sputtering source has been demonstrated to perform superiorly relative to traditional oxygen and cesium ion sputtering sources for ToF-SIMS depth profiling of insulating materials. The superior performance has been attributed to effective alleviation of surface charging. A simulated nuclear waste glass, SON68, and layered hole-perovskite oxide thin films were selected as model systems due to their fundamental and practical significance. Our study shows that if the size of analysis areas is same, the highest sputter rate of argon cluster sputtering can be 2-3 times faster than the highest sputtermore » rates of oxygen or cesium sputtering. More importantly, high quality data and high sputter rates can be achieved simultaneously for argon cluster sputtering while this is not the case for cesium and oxygen sputtering. Therefore, for deep depth profiling of insulating samples, the measurement efficiency of argon cluster sputtering can be about 6-15 times better than traditional cesium and oxygen sputtering. Moreover, for a SrTiO3/SrCrO3 bi-layer thin film on a SrTiO3 substrate, the true 18O/16O isotopic distribution at the interface is better revealed when using the argon cluster sputtering source. Therefore, the implementation of an argon cluster sputtering source can significantly improve the measurement efficiency of insulating materials, and thus can expand the application of ToF-SIMS to the study of glass corrosion, perovskite oxide thin films, and many other potential systems.« less
SIMS depth profiling of working environment nanoparticles
NASA Astrophysics Data System (ADS)
Konarski, P.; Iwanejko, I.; Mierzejewska, A.
2003-01-01
Morphology of working environment nanoparticles was analyzed using sample rotation technique in secondary ion mass spectrometry (SIMS). The particles were collected with nine-stage vacuum impactor during gas tungsten arc welding (GTAW) process of stainless steel and shielded metal arc welding (SMAW) of mild steel. Ion erosion of 300-400 nm diameter nanoparticles attached to indium substrate was performed with 2 keV, 100 μm diameter, Ar + ion beam at 45° ion incidence and 1 rpm sample rotation. The results show that both types of particles have core-shell morphology. A layer of fluorine, chlorine and carbon containing compounds covers stainless steel welding fume particles. The cores of these particles are enriched in iron, manganese and chromium. Outer shell of mild steel welding fume particles is enriched in carbon, potassium, chlorine and fluorine, while the deeper layers of these nanoparticles are richer in main steel components.
Defense in Depth: Foundation for Secure and Resilient IT Enterprises
2006-09-01
Gabbard , D., & May, C. (2003). Outsourcing Managed Security Service. http://www.sei.cmu.edu/publications/documents/sims/sim012.html. 296 CMU/SEI...security_matters/2001/2q01/security-2q01.htm. [Allen 03] Allen, J., Gabbard , D., & May, C. Outsourcing Managed Security Service (CMU/SEI-SIM-012
Investigation of Damage with Cluster Ion Beam Irradiation Using HR-RBS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seki, Toshio; Aoki, Takaaki; Matsuo, Jiro
2008-11-03
Cluster ion beam can process targets with shallow damage because of the very low irradiation energy per atom. However, it is needed to investigate the damage with cluster ion beam irradiation, because recent applications demand process targets with ultra low damage. The shallow damage can be investigated from depth profiles of specific species before and after ion irradiation. They can be measured with secondary ion mass spectrometry (SIMS) and Rutherford backscattering spectroscopy (RBS). High resolution Rutherford backscattering spectroscopy (HR-RBS) is a non destructive measurement method and depth profiles can be measured with nano-resolution. The cluster ion beam mixing of thinmore » Ni layer in carbon targets can be investigated with HR-RBS. The mixing depth with cluster ion irradiation at 10 keV was about 10 nm. The mixing depth with cluster ion irradiation at 1 keV and 5 keV were less than 1 nm and 5 nm, respectively. The number of displaced Ni atoms with cluster ion irradiation was very larger than that with monomer ion irradiation of same energy. This result shows that violent mixing occurs with single cluster impact.« less
Doping of silicon by carbon during laser ablation process
NASA Astrophysics Data System (ADS)
Raciukaitis, G.; Brikas, M.; Kazlauskiene, V.; Miskinis, J.
2007-04-01
Effect of laser ablation on properties of remaining material was investigated in silicon. It was established that laser cutting of wafers in air induced doping of silicon by carbon. The effect was found to be more distinct by the use of higher laser power or UV radiation. Carbon ions created bonds with silicon in the depth of silicon. Formation of the silicon carbide type bonds was confirmed by SIMS, XPS and AES measurements. Modeling of the carbon diffusion was performed to clarify its depth profile in silicon. Photo-chemical reactions of such type changed the structure of material and could be a reason for the reduced quality of machining. A controlled atmosphere was applied to prevent carbonization of silicon during laser cutting.
Doping of silicon with carbon during laser ablation process
NASA Astrophysics Data System (ADS)
Račiukaitis, G.; Brikas, M.; Kazlauskienė, V.; Miškinis, J.
2006-12-01
The effect of laser ablation on properties of remaining material in silicon was investigated. It was found that laser cutting of wafers in the air induced the doping of silicon with carbon. The effect was more distinct when using higher laser power or UV radiation. Carbon ions created bonds with silicon atoms in the depth of the material. Formation of the silicon carbide type bonds was confirmed by SIMS, XPS and AES measurements. Modeling of the carbon diffusion to clarify its depth profile in silicon was performed. Photochemical reactions of such type changed the structure of material and could be the reason of the reduced machining quality. The controlled atmosphere was applied to prevent carbonization of silicon during laser cutting.
Choi, Y.; Eng, P.; Stubbs, J.; ...
2016-08-21
In this paper, X-ray standing wave fluorescence yield depth profiling was used to determine the solar wind implanted Fe and Ni fluences in a silicon-on-sapphire (SoS) Genesis collector (60326). An internal reference standardization method was developed based on fluorescence from Si and Al in the collector materials. Measured Fe fluence agreed well with that measured previously by us on a sapphire collector (50722) as well as SIMS results by Jurewicz et al. Measured Ni fluence was higher than expected by a factor of two; neither instrumental errors nor solar wind fractionation effects are considered significant perturbations to this value. Impuritymore » Ni within the epitaxial Si layer, if present, could explain the high Ni fluences and therefore needs further investigation. As they stand, these results are consistent with minor temporally-variable Fe and Ni fractionation on the timescale of a year.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Y.; Eng, P.; Stubbs, J.
In this paper, X-ray standing wave fluorescence yield depth profiling was used to determine the solar wind implanted Fe and Ni fluences in a silicon-on-sapphire (SoS) Genesis collector (60326). An internal reference standardization method was developed based on fluorescence from Si and Al in the collector materials. Measured Fe fluence agreed well with that measured previously by us on a sapphire collector (50722) as well as SIMS results by Jurewicz et al. Measured Ni fluence was higher than expected by a factor of two; neither instrumental errors nor solar wind fractionation effects are considered significant perturbations to this value. Impuritymore » Ni within the epitaxial Si layer, if present, could explain the high Ni fluences and therefore needs further investigation. As they stand, these results are consistent with minor temporally-variable Fe and Ni fractionation on the timescale of a year.« less
Muramoto, Shin; Brison, Jeremy; Castner, David G.
2011-01-01
The surface sensitivity of Binq+ (n = 1, 3, 5, q = 1, 2) and C60q+ (q = 1, 2) primary ions in static time-of-flight secondary ion mass spectrometry (ToF-SIMS) experiments were investigated for molecular trehalose and polymeric tetraglyme organic films. Parameters related to surface sensitivity (impact crater depth, implantation depth, and molecular escape depths) were measured. Under static ToF-SIMS conditions (primary ion doses of 1 × 1012 ions/cm2), the 25 keV Bi1+ primary ions were the most surface sensitive with a molecular escape depth of 1.8 nm for protein films with tetraglyme overlayers, but they had the deepest implantation depth (~18 and 26 nm in trehalose and tetraglyme films, respectively). The 20 keV C60++ primary ions were the second most surface sensitive with a slightly larger molecular escape depth of 2.3 nm. The most important factor that determined the surface sensitivity of the primary ion was its impact crater depth, or the amount of surface erosion. The most surface sensitive primary ions, Bi1+ and C60++, created impact craters with depths of 0.3 and 1.0 nm, respectively, in tetraglyme films. In contrast, Bi5++ primary ions created impact craters with a depth of 1.8 nm in tetraglyme films and were the least surface sensitive with a molecular escape depth of 4.7 nm. PMID:22084828
Zhang, De-Long; Zhang, Pei; Zhou, Hao-Jiang; Pun, Edwin Yue-Bun
2008-10-01
We have demonstrated the possibility that near-stoichiometric Ti:LiNbO(3) strip waveguides are fabricated by carrying out vapor transport equilibration at 1060 degrees C for 12 h on a congruent LiNbO(3) substrate with photolithographically patterned 4-8 microm wide, 115 nm thick Ti strips. Optical characterizations show that these waveguides are single mode at 1.5 microm and show a waveguide loss of 1.3 dB/cm for TM mode and 1.1 dB/cm for TE mode. In the width/depth direction of the waveguide, the mode field follows the Gauss/Hermite-Gauss function. Secondary-ion-mass spectrometry (SIMS) was used to study Ti-concentration profiles in the depth direction and on the surface of the 6 microm wide waveguide. The result shows that the Ti profile follows a sum of two error functions along the width direction and a complementary error function in the depth direction. The surface Ti concentration, 1/e width and depth, and mean diffusivities along the width and depth directions of the guide are similar to 3.0 x 10(21) cm(-3), 3.8 microm, 2.6 microm, 0.30 and 0.14 microm(2)/h, respectively. Micro-Raman analysis was carried out on the waveguide endface to characterize the depth profile of Li composition in the guiding layer. The results show that the depth profile of Li composition also follows a complementary error function with a 1/e depth of 3.64 microm. The mean ([Li(Li)]+[Ti(Li)])/([Nb(Nb)]+[Ti(Nb)]) ratio in the waveguide layer is about 0.98. The inhomogeneous Li-composition profile results in a varied substrate index in the guiding layer. A two-dimensional refractive index profile model in the waveguide is proposed by taking into consideration the varied substrate index and assuming linearity between Ti-induced index change and Ti concentration. The net waveguide surface index increments at 1545 nm are 0.0114 and 0.0212 for ordinary and extraordinary rays, respectively. Based upon the constructed index model, the fundamental mode field profile was calculated using the beam propagation method, and the mode sizes and effective index versus the Ti-strip width were calculated for three lower TM and TE modes using the variational method. An agreement between theory and experiment is obtained.
NASA Astrophysics Data System (ADS)
Havelund, R.; Seah, M. P.; Tiddia, M.; Gilmore, I. S.
2018-02-01
A procedure has been established to define the interface position in depth profiles accurately when using secondary ion mass spectrometry and the negative secondary ions. The interface position varies strongly with the extent of the matrix effect and so depends on the secondary ion measured. Intensity profiles have been measured at both fluorenylmethyloxycarbonyl-uc(l)-pentafluorophenylalanine (FMOC) to Irganox 1010 and Irganox 1010 to FMOC interfaces for many secondary ions. These profiles show separations of the two interfaces that vary over some 10 nm depending on the secondary ion selected. The shapes of these profiles are strongly governed by matrix effects, slightly weakened by a long wavelength roughening. The matrix effects are separately measured using homogeneous, known mixtures of these two materials. Removal of the matrix and roughening effects give consistent compositional profiles for all ions that are described by an integrated exponentially modified Gaussian (EMG) profile. Use of a simple integrated Gaussian may lead to significant errors. The average interface positions in the compositional profiles are determined to standard uncertainties of 0.19 and 0.14 nm, respectively, using the integrated EMG function. Alternatively, and more simply, it is shown that interface positions and profiles may be deduced from data for several secondary ions with measured matrix factors by simply extrapolating the result to Ξ = 0. Care must be taken in quoting interface resolutions since those measured for predominantly Gaussian interfaces with Ξ above or below zero, without correction, appear significantly better than the true resolution.
Do, Thanh D.; Comi, Troy J.; Dunham, Sage J. B.; Rubakhin, Stanislav S.; Sweedler, Jonathan V.
2017-01-01
A high-throughput single cell profiling method has been developed for matrix-enhanced secondary ion mass spectrometry (ME-SIMS) to investigate the lipid profiles of neuronal cells. Populations of cells are dispersed onto the substrate, their locations determined using optical microscopy, and the cell locations used to guide the acquisition of SIMS spectra from the cells. Up to 2,000 cells can be assayed in one experiment at a rate of 6 s per cell. Multiple saturated and unsaturated phosphatidylcholines (PCs) and their fragments are detected and verified with tandem mass spectrometry from individual cells when ionic liquids are employed as a matrix. Optically guided single cell profiling with ME-SIMS is suitable for a range of cell sizes, from Aplysia californica neurons larger than 75 μm to 7-μm rat cerebellar neurons. ME-SIMS analysis followed by t-distributed stochastic neighbor embedding of peaks in the lipid molecular mass range (m/z 700–850) distinguishes several cell types from the rat central nervous system, largely based on the relative proportions of the four dominant lipids, PC(32:0), PC(34:1), PC(36:1), and PC(38:5). Furthermore, subpopulations within each cell type are tentatively classified consistent with their endogenous lipid ratios. The results illustrate the efficacy of a new approach to classify single cell populations and subpopulations using SIMS profiling of lipid and metabolite contents. These methods are broadly applicable for high throughput single cell chemical analyses. PMID:28194949
Thomas, Joseph P; Zhao, Liyan; Abd-Ellah, Marwa; Heinig, Nina F; Leung, K T
2013-07-16
Conducting p-type polymer layers on n-type Si have been widely studied for the fabrication of cost-effective hybrid solar cells. In this work, time-of-flight secondary ion mass spectrometry (TOF-SIMS) is used to provide three-dimensional chemical imaging of the interface between poly(3,4-ethylene-dioxythiophene):polystyrenesulfonate (PEDOT:PSS) and SiOx/Si in a hybrid solar cell. To minimize structural damage to the polymer layer, an Ar cluster sputtering source is used for depth profiling. The present result shows the formation of micropore defects in the interface region of the PEDOT:PSS layer on the SiOx/Si substrate. This interfacial micropore defect formation becomes more prominent with increasing thickness of the native oxide layer, which is a key device parameter that greatly affects the hybrid solar cell performance. Three-dimensional chemical imaging coupled with Ar cluster ion sputtering has therefore been demonstrated as an emerging technique for probing the interface of this and other polymer-inorganic systems.
Pollak, C; Malic, B; Kosec, M; Javoric, S; Hutter, H
2002-10-01
Chemical solution-deposited thin films of PbZr(0.53)Ti(0.47)O(3)/La(0.5)Sr(0.5)CoO(3) on Pt/TiO(2)/SiO(2)/Si substrates have been investigated by dynamic SIMS. The PbZr(0.53)Ti(0.47)O(3) (PZT) is intended to serve as a ferroelectric layer for microelectronic or microelectromechanical applications; conducting La(0.5)Sr(0.5)CoO(3) (LSCO) is a buffer layer intended to eliminate fatigue effects which usually occur at the Pt/PZT interface. Depth profiles of the main components were obtained and revealed that significant diffusion occurred during the deposition and crystallisation processes. Two types of sample, with different thickness of PZT and different types of poly(vinyl alcohol) (PVA) added to the LSCO precursor, were investigated.
NASA Astrophysics Data System (ADS)
Florentin, L.; Deloule, E.; Faure, F.; Mangin, D.
2018-06-01
Natural glass inclusions - hosted in Mg-rich olivines from Allende (CV3) type I chondrules - and synthetic melt inclusions - trapped in forsterite crystallized from CMAS (CaO-MgO-Al2O3-SiO2) melts - were mapped by Secondary Ion Mass Spectrometry (SIMS) for CMAS major oxides. The first ever 3D chemical images of extra-terrestrial glass inclusions were obtained, along with chemical depth profiles for each oxide. Results show similar patterns for both synthetic glass inclusions (trapped in olivine formed by slow crystallization in a magmatic liquid) and natural inclusions from Allende's olivines. No incompatible-rich boundary layer or diffusion pattern was observed in either case. The absence of an incompatible-rich boundary layer suggests that the olivine overgrowth surrounding glass inclusions in Allende's olivines was formed during slow cooling of the host olivine and likely the surrounding chondrule. This provides new constraints on the cooling rates of type I chondrules.
Müller, Marcel; Mönkemöller, Viola; Hennig, Simon; Hübner, Wolfgang; Huser, Thomas
2016-01-01
Super-resolved structured illumination microscopy (SR-SIM) is an important tool for fluorescence microscopy. SR-SIM microscopes perform multiple image acquisitions with varying illumination patterns, and reconstruct them to a super-resolved image. In its most frequent, linear implementation, SR-SIM doubles the spatial resolution. The reconstruction is performed numerically on the acquired wide-field image data, and thus relies on a software implementation of specific SR-SIM image reconstruction algorithms. We present fairSIM, an easy-to-use plugin that provides SR-SIM reconstructions for a wide range of SR-SIM platforms directly within ImageJ. For research groups developing their own implementations of super-resolution structured illumination microscopy, fairSIM takes away the hurdle of generating yet another implementation of the reconstruction algorithm. For users of commercial microscopes, it offers an additional, in-depth analysis option for their data independent of specific operating systems. As a modular, open-source solution, fairSIM can easily be adapted, automated and extended as the field of SR-SIM progresses. PMID:26996201
Electronic stopping powers for heavy ions in SiC and SiO{sub 2}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, K.; Xue, H.; Zhang, Y., E-mail: Zhangy1@ornl.gov
2014-01-28
Accurate information on electronic stopping power is fundamental for broad advances in materials science, electronic industry, space exploration, and sustainable energy technologies. In the case of slow heavy ions in light targets, current codes and models provide significantly inconsistent predictions, among which the Stopping and Range of Ions in Matter (SRIM) code is the most commonly used one. Experimental evidence, however, has demonstrated considerable errors in the predicted ion and damage profiles based on SRIM stopping powers. In this work, electronic stopping powers for Cl, Br, I, and Au ions are experimentally determined in two important functional materials, SiC andmore » SiO{sub 2}, based on a single ion technique, and new electronic stopping power values are derived over the energy regime from 0 to 15 MeV, where large deviations from the SRIM predictions are observed. As an experimental validation, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC for energies from 700 keV to 15 MeV. The measured ion distributions by both RBS and SIMS are considerably deeper than the SRIM predictions, but agree well with predictions based on our derived stopping powers.« less
Electronic Stopping Powers For Heavy Ions In SiC And SiO2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Ke; Zhang, Y.; Zhu, Zihua
2014-01-24
Accurate information on electronic stopping power is fundamental for broad advances in materials science, electronic industry, space exploration, and sustainable energy technologies. In the case of slow heavy ions in light targets, current codes and models provide significantly inconsistent predictions, among which the Stopping and Range of Ions in Matter (SRIM) code is the most commonly used one. Experimental evidence, however, has demonstrated considerable errors in the predicted ion and damage profiles based on SRIM stopping powers. In this work, electronic stopping powers for Cl, Br, I, and Au ions are experimentally determined in two important functional materials, SiC andmore » SiO2, based on a single ion technique, and new electronic stopping power values are derived over the energy regime from 0 to 15 MeV, where large deviations from the SRIM predictions are observed. As an experimental validation, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC for energies from 700 keV to 15MeV. The measured ion distributions by both RBS and SIMS are considerably deeper than the SRIM predictions, but agree well with predictions based on our derived stopping powers.« less
SIMS study of oxygen diffusion in monoclinic HfO2
NASA Astrophysics Data System (ADS)
Mueller, Michael P.; De Souza, Roger A.
2018-01-01
The diffusion of oxygen in dense ceramics of monoclinic HfO2 was studied by means of (18O/16O) isotope exchange annealing and subsequent determination of isotope depth profiles by Secondary Ion Mass Spectrometry. Anneals were performed in the temperature range of 573 ≤T /K ≤ 973 at an oxygen partial pressure of p O2=200 mbar . All measured isotope profiles exhibited two features: the first feature, closer to the surface, was attributed mainly to slow oxygen diffusion in an impurity silicate phase; the second feature, deeper in the sample, was attributed to oxygen diffusion in bulk monoclinic HfO2 . The activation enthalpy of oxygen tracer diffusion in bulk HfO2 was found to be ΔHD∗≈0.5 eV .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torregrosa, Frank; Etienne, Hasnaa; Mathieu, Gilles
Classical beam line implantation is limited in low energies and cannot achieve P+/N junctions requirements for <45nm node. Compared to conventional beam line ion implantation, limited to a minimum of about 200 eV, the efficiency of Plasma Immersion Ion Implantation (PIII) is no more to prove for the realization of Ultra Shallow Junctions (USJ) in semiconductor applications: this technique allows to get ultimate shallow profiles (as implanted) thanks to no lower limitation of energy and offers high dose rate. In the field of the European consortium NANOCMOS, Ultra Shallow Junctions implanted on a semi-industrial PIII prototype (PULSION registered ) designedmore » by the French company IBS, have been studied. Ultra shallow junctions implanted with BF3 at acceleration voltages down to 20V were realized. Contamination level, homogeneity and depth profile are studied. The SIMS profiles obtained show the capability to make ultra shallow profiles (as implanted) down to 2nm.« less
Zhang, Yijia; Jia, Zhenshan; Yuan, Hongjiang; Dusad, Anand; Ren, Ke; Wei, Xin; Fehringer, Edward V.; Purdue, P. Edward; Daluiski, Aaron; Goldring, Steven R.; Wang, Dong
2016-01-01
Purpose To evaluate the therapeutic efficiency of a micellar prodrug formulation of simvastatin (SIM/SIM-mPEG) and explore its safety in a closed femoral fracture mouse model. Methods The amphiphilic macromolecular prodrug of simvastatin (SIM-mPEG) was synthesized and formulated together with free simvastatin into micelles. It was also labeled with a near infrared dye for in vivo imaging purpose. A closed femoral fracture mouse model was established using a three-point bending device. The mice with established closed femoral fracture were treated with SIM/SIM-mPEG micelle, using free simvastatin and saline as controls. The therapeutic efficacy of the micelles was evaluated using a high-resolution micro-CT. Serum biochemistry and histology analyses were performed to explore the potential toxicity of the micelle formulation. Results Near Infrared Fluorescence (NIRF) imaging confirmed the passive targeting of SIM/SIM-mPEG micelles to the bone lesion of the mice with closed femoral fracture. The micelle was found to promote fracture healing with an excellent safety profile. In addition, the accelerated healing of the femoral fracture also helped to prevent disuse-associated same-side tibia bone loss accompanying the femur fracture. Conclusion SIM/SIM-mPEG micelle was found to be an effective and safe treatment for closed femoral fracture repair in mice. The evidence obtained in this study suggests that it may have the potential to be translated into a novel therapy for clinical management of skeletal fractures and non-union. PMID:27164897
Image recombination transform algorithm for superresolution structured illumination microscopy
Zhou, Xing; Lei, Ming; Dan, Dan; Yao, Baoli; Yang, Yanlong; Qian, Jia; Chen, Guangde; Bianco, Piero R.
2016-01-01
Abstract. Structured illumination microscopy (SIM) is an attractive choice for fast superresolution imaging. The generation of structured illumination patterns made by interference of laser beams is broadly employed to obtain high modulation depth of patterns, while the polarizations of the laser beams must be elaborately controlled to guarantee the high contrast of interference intensity, which brings a more complex configuration for the polarization control. The emerging pattern projection strategy is much more compact, but the modulation depth of patterns is deteriorated by the optical transfer function of the optical system, especially in high spatial frequency near the diffraction limit. Therefore, the traditional superresolution reconstruction algorithm for interference-based SIM will suffer from many artifacts in the case of projection-based SIM that possesses a low modulation depth. Here, we propose an alternative reconstruction algorithm based on image recombination transform, which provides an alternative solution to address this problem even in a weak modulation depth. We demonstrated the effectiveness of this algorithm in the multicolor superresolution imaging of bovine pulmonary arterial endothelial cells in our developed projection-based SIM system, which applies a computer controlled digital micromirror device for fast fringe generation and multicolor light-emitting diodes for illumination. The merit of the system incorporated with the proposed algorithm allows for a low excitation intensity fluorescence imaging even less than 1 W/cm2, which is beneficial for the long-term, in vivo superresolved imaging of live cells and tissues. PMID:27653935
SRF niobium characterization using SIMS and FIB-TEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevie, F. A.
2015-12-04
Our understanding of superconducting radio frequency (SRF) accelerator cavities has been improved by elemental analysis at high depth resolution and by high magnification microscopy. This paper summarizes the technique development and the results obtained on poly-crystalline, large grain, and single crystal SRF niobium. Focused ion beam made possible sample preparation using transmission electron microscopy and the images obtained showed a very uniform oxide layer for all samples analyzed. Secondary ion mass spectrometry indicated the presence of a high concentration of hydrogen and the hydrogen content exhibited a relationship with improvement in performance. Depth profiles of carbon, nitrogen, and oxygen didmore » not show major differences with heat treatment. Niobium oxide less than 10 nm thick was shown to be an effective hydrogen barrier. Niobium with titanium contamination showed unexpected performance improvement.« less
XPS and SIMS study of the surface and interface of aged C + implanted uranium
Donald, Scott B.; Siekhaus, Wigbert J.; Nelson, Art J.
2016-09-08
X-ray photoelectron spectroscopy in combination with secondary ion mass spectrometry depth profiling were used to investigate the surface and interfacial chemistry of C + ion implanted polycrystalline uranium subsequently oxidized in air for over 10 years at ambient temperature. The original implantation of 33 keV C + ions into U 238 with a dose of 4.3 × 10 17 cm –3 produced a physically and chemically modified surface layer that was characterized and shown to initially prevent air oxidation and corrosion of the uranium after 1 year in air at ambient temperature. The aging of the surface and interfacial layersmore » were examined by using the chemical shift of the U 4f, C 1s, and O 1s photoelectron lines. In addition, valence band spectra were used to explore the electronic structure of the aged carbide surface and interface layer. Moreover, the time-of-flight secondary ion mass spectrometry depth profiling results for the aged sample confirmed an oxidized uranium carbide layer over the carbide layer/U metal interface.« less
Mg concentration profile and its control in the low temperature grown Mg-doped GaN epilayer
NASA Astrophysics Data System (ADS)
Liu, S. T.; Yang, J.; Zhao, D. G.; Jiang, D. S.; Liang, F.; Chen, P.; Zhu, J. J.; Liu, Z. S.; Liu, W.; Xing, Y.; Zhang, L. Q.; Wang, W. J.; Li, M.; Zhang, Y. T.; Du, G. T.
2018-01-01
In this work, the Cp2Mg flux and growth pressure influence to Mg doping concentration and depth profiles is studied. From the SIMS measurement we found that a transition layer exists at the bottom region of the layer in which the Mg doping concentration changes gradually. The thickness of transition layer decreases with the increases of Mg doping concentration. Through analysis, we found that this is caused by Ga memory effect which the Ga atoms stay residual in MOCVD system will react with Mg source, leading a transition layer formation and improve the growth rate. And the Ga memory effect can be well suppressed by increasing Mg doping concentration and growth pressure and thus get a steep Mg doping at the bottom region of p type layer.
Lshikawa, Kazutaka; Okamoto, Masayuki; Aoyagi, Satoka
2016-06-28
A hair cuticle, which consists of flat overlapping scales that surround the hair fiber, protects inner tissues against external stimuli. The outermost surface of the cuticle is covered with a thin membrane containing proteins and lipids called the epicuticle. In a previous study, the authors conducted a depth profile analysis of a hair cuticle's amino acid composition to characterize its multilayer structure. Time-of-flight secondary ion mass spectrometry with a bismuth primary ion source was used in combination with the C60 sputtering technique for the analysis. It was confirmed that the lipids and cysteine-rich layer exist on the outermost cuticle surface, which is considered to be the epicuticle, though the detailed structure of the epicuticle has not been clarified. In this study, depth profile analysis of the cuticle surface was conducted using the argon gas cluster ion beam (Ar-GCIB) sputtering technique, in order to characterize the structure of the epicuticle. The shallow depth profile of the cuticle surface was investigated using an Ar-GCIB impact energy of 5 keV. Compared to the other amino acid peaks rich in the epicuticle, the decay of 18-methyleicosanic acid (18-MEA) thiolate peak was the fastest. This result suggests that the outermost surface of the hair is rich in 18-MEA. In conclusion, our results indicate that the outermost surfaces of cuticles have a multilayer (lipid and protein layers), which is consistent with the previously proposed structure.
NASA Astrophysics Data System (ADS)
Trocellier, P.; Djanarthany, S.; Chêne, J.; Haddi, A.; Brass, A. M.; Poissonnet, S.; Farges, F.
2005-10-01
Simple and complex alkali-borosilicate glasses were submitted to aqueous corrosion at room temperature, 60 and 90 °C in solutions with pH ranging between 0 and 12. Analytical scanning electron microscopy (SEM), ion beam analysis (IBA) techniques, isotopic tracing and secondary ion mass-depth profiling (SIMS) have been used to investigate the variations of the surface composition of glass. In acidic medium, the glass surface is generally covered by a thick hydrated silica layer, mobile elements like Li, Na and B and transition elements (Fe, Zr, Mo, etc.) are strongly depleted. Near pH 7, relative enrichments of aluminium, iron and rare earths are shown together with strong Li, Na and B depletions. In basic medium, the glass surface exhibits relative enrichments of the major part of transition metals (from Cr to U) whereas mobile elements seem to be kept close to their nominal concentration level at the glass surface and Si is severely impoverished. Hydrogen incorporated at the glass surface after leaching is much more immobile in neutral and basic media than in acid medium.
Comparative study of the native oxide on 316L stainless steel by XPS and ToF-SIMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tardio, Sabrina, E-mail: s.tardio@surrey.ac.uk; Abel, Marie-Laure; Castle, James E.
2015-09-15
The very thin native oxide film on stainless steel, of the order of 2 nm, is known to be readily modified by immersion in aqueous media. In this paper, X-ray photoelectron spectroscopy (XPS) and time of flight secondary ions mass spectrometry are employed to investigate the nature of the air-formed film and modification after water emersion. The film is described in terms of oxide, hydroxide, and water content. The preferential dissolution of iron is shown to occur on immersion. It is shown that a water absorbed layer and a hydroxide layer are present above the oxide-like passive film. The concentrations ofmore » water and hydroxide appear to be higher in the case of exposure to water. A secure method for the peak fitting of Fe2p and Cr2p XPS spectra of such films on their metallic substrates is described. The importance of XPS survey spectra is underlined and the feasibility of C{sub 60}{sup +} SIMS depth profiling of a thin oxide layer is shown.« less
Judd, Amy M; Scurr, David J; Heylings, Jon R; Wan, Ka-Wai; Moss, Gary P
2013-07-01
In order to increase the efficacy of a topically applied antimicrobial compound the permeation profile, localisation and mechanism of action within the skin must first be investigated. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to visualise the distribution of a conventional antimicrobial compound, chlorhexidine digluconate, within porcine skin without the need for laborious preparation, radio-labels or fluorescent tags. High mass resolution and high spatial resolution mass spectra and chemical images were achieved when analysing chlorhexidine digluconate treated cryo-sectioned porcine skin sections by ToF-SIMS. The distribution of chlorhexidine digluconate was mapped throughout the skin sections and our studies indicate that the compound appears to be localised within the stratum corneum. In parallel, tape strips taken from chlorhexidine digluconate treated porcine skin were analysed by ToF-SIMS to support the distribution profile obtained from the skin sections. ToF-SIMS can act as a powerful complementary technique to map the distribution of topically applied compounds within the skin.
The OncoSim model: development and use for better decision-making in Canadian cancer control.
Gauvreau, C L; Fitzgerald, N R; Memon, S; Flanagan, W M; Nadeau, C; Asakawa, K; Garner, R; Miller, A B; Evans, W K; Popadiuk, C M; Wolfson, M; Coldman, A J
2017-12-01
The Canadian Partnership Against Cancer was created in 2007 by the federal government to accelerate cancer control across Canada. Its OncoSim microsimulation model platform, which consists of a suite of specific cancer models, was conceived as a tool to augment conventional resources for population-level policy- and decision-making. The Canadian Partnership Against Cancer manages the OncoSim program, with funding from Health Canada and model development by Statistics Canada. Microsimulation modelling allows for the detailed capture of population heterogeneity and health and demographic history over time. Extensive data from multiple Canadian sources were used as inputs or to validate the model. OncoSim has been validated through expert consultation; assessments of face validity, internal validity, and external validity; and model fit against observed data. The platform comprises three in-depth cancer models (lung, colorectal, cervical), with another in-depth model (breast) and a generalized model (25 cancers) being in development. Unique among models of its class, OncoSim is available online for public sector use free of charge. Users can customize input values and output display, and extensive user support is provided. OncoSim has been used to support decision-making at the national and jurisdictional levels. Although simulation studies are generally not included in hierarchies of evidence, they are integral to informing cancer control policy when clinical studies are not feasible. OncoSim can evaluate complex intervention scenarios for multiple cancers. Canadian decision-makers thus have a powerful tool to assess the costs, benefits, cost-effectiveness, and budgetary effects of cancer control interventions when faced with difficult choices for improvements in population health and resource allocation.
Doping profile measurement on textured silicon surface
NASA Astrophysics Data System (ADS)
Essa, Zahi; Taleb, Nadjib; Sermage, Bernard; Broussillou, Cédric; Bazer-Bachi, Barbara; Quillec, Maurice
2018-04-01
In crystalline silicon solar cells, the front surface is textured in order to lower the reflection of the incident light and increase the efficiency of the cell. This texturing whose dimensions are a few micrometers wide and high, often makes it difficult to determine the doping profile measurement. We have measured by secondary ion mass spectrometry (SIMS) and electrochemical capacitance voltage profiling the doping profile of implanted phosphorus in alkaline textured and in polished monocrystalline silicon wafers. The paper shows that SIMS gives accurate results provided the primary ion impact angle is small enough. Moreover, the comparison between these two techniques gives an estimation of the concentration of electrically inactive phosphorus atoms.
Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol
2015-06-05
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states.
Park, Ji-Won; Jeong, Hyobin; Kang, Byeongsoo; Kim, Su Jin; Park, Sang Yoon; Kang, Sokbom; Kim, Hark Kyun; Choi, Joon Sig; Hwang, Daehee; Lee, Tae Geol
2015-01-01
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) emerges as a promising tool to identify the ions (small molecules) indicative of disease states from the surface of patient tissues. In TOF-SIMS analysis, an enhanced ionization of surface molecules is critical to increase the number of detected ions. Several methods have been developed to enhance ionization capability. However, how these methods improve identification of disease-related ions has not been systematically explored. Here, we present a multi-dimensional SIMS (MD-SIMS) that combines conventional TOF-SIMS and metal-assisted SIMS (MetA-SIMS). Using this approach, we analyzed cancer and adjacent normal tissues first by TOF-SIMS and subsequently by MetA-SIMS. In total, TOF- and MetA-SIMS detected 632 and 959 ions, respectively. Among them, 426 were commonly detected by both methods, while 206 and 533 were detected uniquely by TOF- and MetA-SIMS, respectively. Of the 426 commonly detected ions, 250 increased in their intensities by MetA-SIMS, whereas 176 decreased. The integrated analysis of the ions detected by the two methods resulted in an increased number of discriminatory ions leading to an enhanced separation between cancer and normal tissues. Therefore, the results show that MD-SIMS can be a useful approach to provide a comprehensive list of discriminatory ions indicative of disease states. PMID:26046669
NanoSIMS for biological applications: Current practices and analyses
Nunez, Jamie R.; Renslow, Ryan S.; Cliff, III, John B.; ...
2017-09-27
Secondary ion mass spectrometry (SIMS) has become an increasingly utilized tool in biologically-relevant studies. Of these, high lateral resolution methodologies using the NanoSIMS 50/50L have been especially powerful within many biological fields over the past decade. Here, we provide a review of this technology, sample preparation and analysis considerations, examples of recent biological studies, data analysis, and current outlooks. Specifically, we offer an overview of SIMS and development of the NanoSIMS. We describe the major experimental factors that should be considered prior to NanoSIMS analysis and then provide information on best practices for data analysis and image generation, which includesmore » an in-depth discussion of appropriate colormaps. Additionally, we provide an open-source method for data representation that allows simultaneous visualization of secondary electron and ion information within a single image. Lastly, we present a perspective on the future of this technology and where we think it will have the greatest impact in near future.« less
NanoSIMS for biological applications: Current practices and analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nunez, Jamie R.; Renslow, Ryan S.; Cliff, III, John B.
Secondary ion mass spectrometry (SIMS) has become an increasingly utilized tool in biologically-relevant studies. Of these, high lateral resolution methodologies using the NanoSIMS 50/50L have been especially powerful within many biological fields over the past decade. Here, we provide a review of this technology, sample preparation and analysis considerations, examples of recent biological studies, data analysis, and current outlooks. Specifically, we offer an overview of SIMS and development of the NanoSIMS. We describe the major experimental factors that should be considered prior to NanoSIMS analysis and then provide information on best practices for data analysis and image generation, which includesmore » an in-depth discussion of appropriate colormaps. Additionally, we provide an open-source method for data representation that allows simultaneous visualization of secondary electron and ion information within a single image. Lastly, we present a perspective on the future of this technology and where we think it will have the greatest impact in near future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torregrosa, Frank; Etienne, Hasnaa; Sempere, Guillaume
In order to achieve the requirements for P+/N junctions for <45 nm ITRS nodes, ultra low energy and high dose implantations are needed. Classical beamline implantation is now limited in low energies, compared to Plasma Immersion Ion Implantation (PIII) which efficiency is no more to prove for the realization of Ultra-Shallow Junctions (USJ) in semiconductor applications : this technique allows to get ultimate shallow profiles (as implanted) due to no lower limitation of energy and high dose rate. Electrical activation is also a big issue since it has to afford high electrical activation rate with very low diffusion. Laser annealingmore » is one of the candidates for the 45 nm node. This paper presents electrical and physico-chemical characterizations of junctions realized with BF3 PIII followed by laser thermal processing with aim to obtain ultra-shallow junctions. Different implantation conditions (acceleration voltage/dose) and laser conditions (laser types, fluence/number of shots) are used for this study. Pre-amorphization is also used to confine the junction depth, and is shown to have a positive effect on junction depth but leads in higher junction leakage due to the remaining of EOR defects. The characterization is done using Optical characterization tool (SEMILAB) for sheet resistance and junction leakage measurements. SIMS is used for Boron profile and junction depth.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oudriss, A.; Le Guernic, Solenne; Wang, Zhaoying
2016-02-15
To study anisotropic hydrogen segregation and diffusion in nickel polycrystalline, Secondary Ion Mass Spectrometry (SIMS) and Electron Back Scattered Diffraction (EBSD) are integrated to investigate hydrogen distribution around grain boundaries. Hydrogen distribution in pre-charged samples were correlated with grain boundary character by integrating high-resolution grain microstructure from EBSD inverse pole figure map and low-resolution hydrogen concentration profile map from SIMS. This multimodal imaging instrumentation shows that grain boundaries in nickel can be categorized into two families based on behavior of hydrogen distribution crossing grain boundary: the first one includes random grain boundaries with fast hydrogen diffusivity, showing a sharp gapmore » for hydrogen concentration profile cross the grain boundaries. The second family are special Σ3n grain boundaries with low hydrogen diffusivity, showing a smooth gradient of hydrogen concentration cross the grain boundary. Heterogeneous hydrogen distributions due to grain boundary family revealed by SIMS/EBSD on mesoscale further validate the recent hydrogen permeation data and anisotropic ab-initio calculations in nanoscale. The results highlight the fact that grain boundaries character impacts hydrogen distribution significantly.« less
Opto-Electronic Characterization CdTe Solar Cells from TCO to Back Contact with Nano-Scale CL Probe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moseley, John; Al-Jassim, Mowafak M.; Paudel, Naba
2015-06-14
We used cathodoluminescence (CL) (spectrum-per-pixel) imaging on beveled CdTe solar cell sections to investigate the opto-electronic properties of these devices from the TCO to the back contact. We used a nano-scale CL probe to resolve luminescence from grain boundary (GB) and grain interior (GI) locations near the CdS/CdTe interface where the grains are very small. As-deposited, CdCl2-treated, Cu-treated, and (CdCl2+Cu)-treated cells were analyzed. Color-coded CL spectrum imaging maps on bevels illustrate the distribution of the T=6 K luminescence transitions through the depth of devices with unprecedented spatial resolution. The CL at the GBs and GIs is shown to vary significantlymore » from the front to the back of devices and is a sensitive function of processing. Supporting D-SIMS depth profile, TRPL lifetime, and C-V measurements are used to link the CL data to the J-V performance of devices.« less
NanoSIMS analysis of Bacillus spores for forensics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, P K; Davisson, M L; Velsko, S P
2010-02-23
The threat associated with the potential use of radiological, nuclear, chemical and biological materials in terrorist acts has resulted in new fields of forensic science requiring the application of state-of-the-science analytical techniques. Since the anthrax letter attacks in the United States in the fall of 2001, there has been increased interest in physical and chemical characterization of bacterial spores. While molecular methods are powerful tools for identifying genetic differences, other methods may be able to differentiate genetically identical samples based on physical and chemical properties, as well as provide complimentary information, such as methods of production and approximate date ofmore » production. Microanalysis has the potential to contribute significantly to microbial forensics. Bacillus spores are highly structured, consisting of a core, cortex, coat, and in some species, an exosporium. This structure provides a template for constraining elemental abundance differences at the nanometer scale. The primary controls on the distribution of major elements in spores are likely structural and physiological. For example, P and Ca are known to be abundant in the spore core because that is where P-rich nucleic acids and Cadipicolinic acid are located, respectively. Trace elements are known to bind to the spore coat but the controls on these elements are less well understood. Elemental distributions and abundances may be directly related to spore production, purification and stabilization methodologies, which are of particular interest for forensic investigation. To this end, we are developing a high-resolution secondary ion mass spectrometry method using a Cameca NanoSIMS 50 to study the distribution and abundance of trace elements in bacterial spores. In this presentation we will review and compare methods for preparing and analyzing samples, as well as review results on the distribution and abundance of elements in bacterial spores. We use NanoSIMS to directly image samples as well as depth profile samples. The directly imaged samples are sectioned to present a flat surface for analysis. We use focused ion beam (FIB) milling to top-cut individual spores to create flat surfaces for NanoSIMS analysis. Depth profiling can be used on whole spores, which are consumed in the process of analysis. The two methods generate comparable results, with the expected distribution of P and Ca. Ca-compatible elements, such as Mg and Mn, are found to follow the distribution of Ca. The distribution of other elements will be discussed. We envision the first application of this methodology will be to sample matching for trace samples. Towards this end, we are generating a baseline data set for samples produced by multiple laboratories. Preliminary results suggest that this method provides significant probative value for identifying samples produced by the same method in the same laboratory, as well as coming from the same initial production run. The results of this study will be presented.« less
Holmes, Amy M; Scurr, David J; Heylings, Jon R; Wan, Ka-Wai; Moss, Gary P
2017-06-15
Skin penetration and localisation of chlorhexidine digluconate (CHG) within the skin have been investigated in order to better understand and optimise the delivery using a nano polymeric delivery system of this topically-applied antimicrobial drug. Franz-type diffusion cell studies using in vitro porcine skin and tape stripping procedures were coupled with Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to visualise the skin during various treatments with CHG and polyamidoamine dendrimers (PAMAM). Pre-treatment of the skin with PAMAM dendrimers significantly increased the amount and depth of permeation of CHG into the skin in vitro. The effect observed was not concentration dependant in the range 0.5-10mM PAMAM. This could be important in terms of the efficiency of treatment of bacterial infection in the skin. It appears that the mechanism of enhancement is due to the PAMAM dendrimer disrupting skin barrier lipid conformation or by occluding the skin surface. Franz-type diffusion cell experiments are complimented by the detailed visualisation offered by the semi-quantitative ToF-SIMS method which provides excellent benefits in terms of sensitivity and fragment ion specificity. This allows a more accurate depth profile of chlorhexidine permeation within the skin to be obtained and potentially affords the opportunity to map the co-localisation of permeants with skin structures, thus providing a greater ability to characterise skin absorption and to understand the mechanism of permeation, providing opportunities for new and more effective therapies. Copyright © 2017. Published by Elsevier B.V.
Bardoczi, Laszlo; Rhodes, Terry L.; Navarro, Alejandro Banon; ...
2017-03-03
We present the first localized measurements of long and intermediate wavelength turbulent density fluctuations (more » $$\\sim\\atop{n}$$) and long wavelength turbulent electron temperature fluctuations ($$\\sim\\atop{T}$$ e) modified by m/n = 2/1 Neoclassical Tearing Mode (NTM) islands (m and n are the poloidal and toroidal mode numbers, respectively). These long and intermediate wavelengths correspond to the expected Ion Temperature Gradient and Trapped Electron Mode scales, respectively. Two regimes have been observed when tracking $$\\sim\\atop{n}$$ during NTM evolution: (1) small islands are characterized by a steep T e radial profile and turbulence levels comparable to those of the background; (2) large islands have a flat T e profile and reduced turbulence level at the O-point. Radially outside the large island, the T e profile is steeper and the turbulence level increased compared to the no or small island case. Reduced turbulence at the O-point compared to the X-point leads to a 15% modulation of $$\\sim\\atop{n}$$ 2 across the island that is nearly in phase with the T e modulation. Qualitative comparisons to the GENE non-linear gyrokinetic code are promising with GENE replicating the observed scaling of turbulence modification with island size. Furthermore, these results are significant as they allow the validation of gyrokinetic simulations modeling the interaction of these multi-scale phenomena.« less
Deployment and early results from the CanSIM (Canadian Solar Spectral Irradiance Meter) network
NASA Astrophysics Data System (ADS)
Tatsiankou, Viktar; Hinzer, Karin; Schriemer, Henry; McVey-White, Patrick; Beal, Richard
2017-09-01
Three of seven stations have been deployed as part of the Canadian Solar Spectral Irradiance (CanSIM) network situated in Ottawa, Varennes and Egbert to measure long term spectral variation of the direct normal (DNI) and global horizontal irradiances (GHI) across the country. Every station is equipped with a solar tracker, SolarSIM-D2+, SolarSIM-G+, and SR20 pyranometer, reporting the spectral DNI, GHI, diffuse horizontal irradiance (DHI) and aerosol optical depth in the 280-4000 nm range, broadband DNI, GHI, and DHI, atmospheric total column ozone and water vapour amounts. The spectral GHI as measured by the SolarSIM-G+ was within 5% as compared to EKO MS-700 spectroradiometer in 350-1050 nm range on 17 March 2017. The difference in the GHI as reported by SolarSIM-G+ and SR20 pyranometer from all stations was within 2% on 14 April 2017. Furthermore, on this day, the daily GHI sum for the Ottawa, Varennes, and Egbert stations was 7.01, 6.95, and 7.11 kWh/m2, respectively, while the daily DNI sum was 10.65, 10.86, 10.04 kWh/m2, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernard, Laetitia, E-mail: laetitia.bernard@empa.ch; Leemann, Andreas
In this study, the potential of time-of-flight secondary ion mass spectrometry (ToF-SIMS) for the application in cement-based materials is assessed in combination and comparison with scanning electron microscopy (SEM) and energy dispersive X-ray (EDX). Mortar, concrete and samples from model systems providing products formed by the alkali–silica reaction (ASR) were studied. ToF-SIMS provides qualitative data on alkalis in cases where EDX reaches its limits in regard to detectable concentration, lateral resolution and atomic number of the elements. Due to its high in-depth resolution of a few atomic monolayers, thin layers of reaction products can be detected on the surfaces andmore » chemically analyzed with ToF-SIMS. Additionally, it delivers information on the molecular conformation within the ASR product, its hydrogen content and its isotope ratios, information not provided by EDX. Provided the samples are carefully prepared, ToF-SIMS opens up new possibilities in the analysis of cement-based materials.« less
CCQM Pilot Study CCQM-P140: Quantitative surface analysis of multi-element alloy films
NASA Astrophysics Data System (ADS)
Kim, Kyung Joong; Jang, Jong Shik; Kim, An Soon; Suh, Jung Ki; Chung, Yong-Duck; Hodoroaba, Vasile-Dan; Wirth, Thomas; Unger, Wolfgang; Kang, Hee Jae; Popov, Oleg; Popov, Inna; Kuselman, Ilya; Lee, Yeon Hee; Sykes, David E.; Wang, Meiling; Wang, Hai; Ogiwara, Toshiya; Nishio, Mitsuaki; Tanuma, Shigeo; Simons, David; Szakal, Christopher; Osborn, William; Terauchi, Shinya; Ito, Mika; Kurokawa, Akira; Fujimoto, Toshiyuki; Jordaan, Werner; Jeong, Chil Seong; Havelund, Rasmus; Spencer, Steve; Shard, Alex; Streeck, Cornelia; Beckhoff, Burkhard; Eicke, Axel; Terborg, Ralf
2015-01-01
A pilot study for a quantitative surface analysis of multi-element alloy films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The aim of this pilot study is to evaluate a protocol for a key comparison to demonstrate the equivalence of measures by National Metrology Institutes (NMIs) and Designated Institutes (DI) for the mole fractions of multi-element alloy films. A Cu(In,Ga)Se2 (CIGS) film with non-uniform depth distribution was chosen as a representative multi-element alloy film. The mole fractions of the reference and the test CIGS films were certified by isotope dilution—inductively coupled plasma/mass spectrometry. A total number counting (TNC) method was used as a method to determine the signal intensities of the constituent elements acquired in SIMS, XPS and AES depth profiling. TNC method is comparable with the certification process because the certified mole fractions are the average values of the films. The mole fractions of the CIGS films were measured by Secondary Ion Mass Spectrometry (SIMS), Auger Electron Spectroscopy (AES), X-ray Photoelectron Spectroscopy (XPS), X-Ray Fluorescence (XRF) Analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX). Fifteen laboratories from eight NMIs, one DI, and six non-NMIs participated in this pilot study. The average mole fractions of the reported data showed relative standard deviations from 5.5 % to 6.8 % and average relative expanded uncertainties in the range from 4.52 % to 4.86 % for the four test CIGS specimens. These values are smaller than those in the key comparison CCQM-K67 for the measurement of mole fractions of Fe-Ni alloy films. As one result it can be stated that SIMS, XPS and AES protocols relying on the quantification of CIGS films using the TNC method are mature to be used in a CCQM key comparison. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by CCQM.
Depth-Resolved Cathodoluminescence of Thorium Dioxide
2013-03-01
exhibited more of an energy dependency than the cut and polished sample. However, in a companion study, ime of flight secondary ion mass spectrometry...Ion Mass Spectrometry (TOF SIMS) ......................17 2.7 Atomic Force Microscope (AFM...1 TOF SIMS……….Time of Flight Secondary Ion Mass Spectroscopy……………….62 1 DEPTH
Hogle, Nancy J; Widmann, Warren D; Ude, Aku O; Hardy, Mark A; Fowler, Dennis L
2008-01-01
To determine whether LapSim training (version 3.0; Surgical Science Ltd, Göteborg, Sweden) to criteria for novice PGY1 surgical residents had predictive validity for improvement in the performance of laparoscopic cholecystectomy. In all, 21 PGY1 residents performed laparoscopic cholecystectomies in pigs after minimal training; their performance was evaluated by skilled laparoscopic surgeons using the validated tool GOALS (global operative assessment of laparoscopic operative skills: depth perception, bimanual dexterity, efficiency, tissue handling, and overall competence). From the group, 10 residents trained to competency on the LapSim Basic Skills Programs (camera navigation, instrument navigation, coordination, grasping, lifting and grasping, cutting, and clip applying). All 21 PGY1 residents again performed laparoscopic cholecystectomies on pigs; their performance was again evaluated by skilled laparoscopic surgeons using GOALS. Additionally, we studied the rate of learning to determine whether the slow or fast learners on the LapSim performed equivalently when performing actual cholecystectomies in pigs. Finally, 6 categorical residents were tracked, and their clinical performance on all of the laparoscopic cholecystectomies in which they were "surgeon, junior" was prospectively evaluated using the GOALS criteria. We found a statistical improvement of depth perception in the operative performance of cholecystectomies in pigs in the group trained on the LapSim. In the other 4 domains, a trend toward improvement was observed. No correlation between being a fast learner and the ultimate skill was demonstrated in the clinical performance of laparoscopic cholecystectomies. We did find that the fast learners on LapSim all were past or current video game players ("gamers"); however, that background did not translate into better clinical performance. Using current criteria, we doubt that the time and effort spent training novice PGY1 Surgical Residents on the basic LapSim training programs is justified, as such training to competence lacks predictive validity in most domains of the GOALS program. We are investigating 2 other approaches: more difficult training exercises using the LapSim system and an entirely different approach using haptic technology (ProMis; Haptica Ltd., Ireland), which uses real instruments, with training on realistic 3-dimensional models with real rather than simulated cutting, sewing, and dissection. Although experienced video gamers achieve competency faster than nongamers on LapSim programs, that skill set does not translate into improved clinical performance.
Combined SIMS, NanoSIMS, FTIR, and SEM Studies of OH in Nominally Anhydrous Minerals (NAMs)
NASA Astrophysics Data System (ADS)
Mosenfelder, J. L.; Le Voyer, M.; Rossman, G. R.; Guan, Y.; Bell, D. R.; Asimow, P. D.; Eiler, J.
2010-12-01
The accurate analysis of trace concentrations of hydrogen in NAMs is a long-standing problem, with wide-ranging implications in geology and planetology. SIMS and FTIR are two powerful and complementary analytical tools capable of measuring concentrations down to levels of less than 1 ppm H2O. Both methods, however, are subject to matrix effects and rely on other techniques such as manometry or nuclear reaction analysis (NRA) for quantitative calibration. We compared FTIR and SIMS data for a wide variety of NAMs: olivine, orthopyroxene, clinopyroxene, pyrope and grossular garnet, rutile, zircon, kyanite, andalusite, and sillimanite. Some samples were also characterized using high-resolution FE-SEM to assess the potential contribution of submicrocopic inclusions to the analyses. For SIMS, we use high mass resolution (≥5000 MRP) to measure 16O1H, using 30Si and/or 18O as reference isotopes. We use both primary standards, measured independently using manometry or NRA (e.g., [1]), and secondary standards, measured using polarized FTIR referenced back to calibrations developed on primary standards. Our major focus was on on olivine, for which we collected repeated calibration data with both SIMS and NanoSIMS, bracketing measurements of H diffusion profiles in both natural and experimentally annealed crystals at levels of 5-100 ppm H2O. With both instruments we establish low blanks (≤5 ppm) and high precision (typically less than 5% 2-σ errors in 16O1H/30Si), critical requirements for the low concentration levels being measured. Assessment of over 300 analyses on 11 olivines allows us to evaluate the suitability of different standards, several of which are in use in other laboratories [2,3,4]. Seven olivines, with 0-125 ppm H2O, give highly reproducible results and allow us to establish well-constrained calibration slopes with high correlation coefficients (r2 = 0.98-99), in contrast to previous studies [2,3,4]. However, four kimberlitic megacrysts with 140-243 ppm H2O show 16O1H/30Si ratios that vary by up to a factor of 2 even in sequential analyses (cf. [3,4]). A potential cause of these discrepancies is the presence of sub-micron scale pores (as small as 100 nm), which we have documented by SEM. These pores probably contain liquid H2O and/or condensed hydrous phase precipitates. Although the ionization potential of fluids under high-vacuum conditions is an under-studied problem, these sub-micron features may contribute to the measured 16O1H, resulting in analyses with erratic depth profiles and corresponding high uncertainties (up to 15% 2-σ). However, if we omit analyses with such high uncertainties, the data for all olivines fit well together. Our results imply that the Bell et al. IR calibration [1] can be applied accurately to all olivines with IR bands from ~3400-3650 cm-1, without the need for band-specific IR absorption coefficients (cf. [3]). A five-fold total variation was observed among the calibration line slopes for the different minerals analyzed, confirming the need for mineral-specific calibrations. [1]Bell et al. (2003), JGR, 108 [2] Tenner et al. (2009), Chem. Geol., 262, 42-56 [3] Kovács, I. et al. (2010), Am. Min., 95, 292-299 [4] O'Leary et al. (2010), EPSL
Ingerle, D.; Meirer, F.; Pepponi, G.; Demenev, E.; Giubertoni, D.; Wobrauschek, P.; Streli, C.
2014-01-01
The continuous downscaling of the process size for semiconductor devices pushes the junction depths and consequentially the implantation depths to the top few nanometers of the Si substrate. This motivates the need for sensitive methods capable of analyzing dopant distribution, total dose and possible impurities. X-ray techniques utilizing the external reflection of X-rays are very surface sensitive, hence providing a non-destructive tool for process analysis and control. X-ray reflectometry (XRR) is an established technique for the characterization of single- and multi-layered thin film structures with layer thicknesses in the nanometer range. XRR spectra are acquired by varying the incident angle in the grazing incidence regime while measuring the specular reflected X-ray beam. The shape of the resulting angle-dependent curve is correlated to changes of the electron density in the sample, but does not provide direct information on the presence or distribution of chemical elements in the sample. Grazing Incidence XRF (GIXRF) measures the X-ray fluorescence induced by an X-ray beam incident under grazing angles. The resulting angle dependent intensity curves are correlated to the depth distribution and mass density of the elements in the sample. GIXRF provides information on contaminations, total implanted dose and to some extent on the depth of the dopant distribution, but is ambiguous with regard to the exact distribution function. Both techniques use similar measurement procedures and data evaluation strategies, i.e. optimization of a sample model by fitting measured and calculated angle curves. Moreover, the applied sample models can be derived from the same physical properties, like atomic scattering/form factors and elemental concentrations; a simultaneous analysis is therefore a straightforward approach. This combined analysis in turn reduces the uncertainties of the individual techniques, allowing a determination of dose and depth profile of the implanted elements with drastically increased confidence level. Silicon wafers implanted with Arsenic at different implantation energies were measured by XRR and GIXRF using a combined, simultaneous measurement and data evaluation procedure. The data were processed using a self-developed software package (JGIXA), designed for simultaneous fitting of GIXRF and XRR data. The results were compared with depth profiles obtained by Secondary Ion Mass Spectrometry (SIMS). PMID:25202165
Stability of Fe-Cr alloy interconnects under CH 4-H 2O atmosphere for SOFCs
NASA Astrophysics Data System (ADS)
Horita, Teruhisa; Xiong, Yueping; Yamaji, Katsuhiko; Sakai, Natsuko; Yokokawa, Harumi
The chemical stability of Fe-Cr alloys (ZMG232 and SUS430) was examined under humidified CH 4 gases at 1073 K to simulate the real anode atmosphere in SOFC operation. Surface microstructure change and oxide scale layer formation were observed on the oxidized Fe-Cr alloy surfaces. The main reaction products were Mn-Cr-(Fe) spinels for both alloys. Secondary ion mass spectrometry (SIMS) was applied to measure the elemental distribution of minor and major elements around the oxide scale/alloy interface. A high concentration of Mn on the oxide scale surface suggested the fast diffusion of Mn in the oxide scale to form the spinels. Annealing in CH 4-H 2O made the oxide scale thicker with duration time on the alloy surface. The parabolic growth rates ( kp) of oxide scale layer were evaluated from the thickness of oxide scales by secondary ion mass spectrometry (SIMS) depth profiles, which were calculated to the following: kp=6.25×10 -6 μm 2/s for SUS430 and kp=4.42×10 -6 μm 2/s for ZMG232. The electrical conductivity of oxidized alloys showed the semi-conductor temperature dependence for both alloys. The electrical conductivity of oxidized ZMG232 alloy was higher than that of oxidized SUS430.
Bioforensics: Characterization of biological weapons agents by NanoSIMS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, P K; Ghosal, S; Leighton, T J
2007-02-26
The anthrax attacks of Fall 2001 highlight the need to develop forensic methods based on multiple identifiers to determine the origin of biological weapons agents. Genetic typing methods (i.e., DNA and RNA-based) provide one attribution technology, but genetic information alone is not usually sufficient to determine the provenance of the material. Non-genetic identifiers, including elemental and isotopic signatures, provide complementary information that can be used to identify the means, geographic location and date of production. Under LDRD funding, we have successfully developed the techniques necessary to perform bioforensic characterization with the NanoSIMS at the individual spore level. We have developedmore » methods for elemental and isotopic characterization at the single spore scale. We have developed methods for analyzing spore sections to map elemental abundance within spores. We have developed rapid focused ion beam (FIB) sectioning techniques for spores to preserve elemental and structural integrity. And we have developed a high-resolution depth profiling method to characterize the elemental distribution in individual spores without sectioning. We used these newly developed methods to study the controls on elemental abundances in spores, characterize the elemental distribution of in spores, and to study elemental uptake by spores. Our work under this LDRD project attracted FBI and DHS funding for applied purposes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, M. K.
The purpose of the work proposed for this study is to investigate the behavior and transport mechanisms for cesium-137 in soils collected from contaminated sites with distinct source release scenarios. More specifically, this study aims to determine with which elements and minerals cesium-137 associates in these various environments to more reliably predict its migration in the subsurface. This will be achieved using a state-of-the-art analysis technique available at Lawrence Livermore National Laboratory (LLNL) known as NanoSIMS. Nano-scale secondary ion mass spectrometry, or NanoSIMS, is a destructive surface analysis technique in which positive secondary ions are generated from the surface ofmore » a sample and then quantified based on their mass-to-charge ratio (m/z) using mass spectrometry. The data collected about the secondary ions can then be used to create isotope-specific spatial maps with a resolution of a few hundred nanometers and depth profiles that show the variation of the secondary ion intensity with sputtering time. This should be an ideal technique for locating cesium-137 in a sample, as cesium is an easily ionized element, meaning the yield of secondary cesium (Cs) ions produced should be high and making the identification of cesium-137 straight forward.« less
A study of dynamic SIMS analysis of low-k dielectric materials
NASA Astrophysics Data System (ADS)
Mowat, Ian A.; Lin, Xue-Feng; Fister, Thomas; Kendall, Marius; Chao, Gordon; Yang, Ming Hong
2006-07-01
Dynamic SIMS is an established tool for the characterization of dielectric layers in semiconductors, both for contaminant levels and for composition. As the silicon-based semiconductor industry moves towards the use of copper rather than aluminum, there is also a need to use lower k-dielectric materials to reduce RC delays and to reduce cross-talk between closely spaced metal lines. New dielectric materials pose serious challenges for implementation into semiconductor processes and also for the analytical scientist doing measurements on them. The move from inorganic materials such as SiO 2 to organic or carbon-rich low-k materials is a large change for the SIMS analyst. Low-k dielectric films from different sources can be very different materials with different analytical issues. A SIMS challenge for these materials is dealing with their insulating nature and their also fragility, particularly for porous films. These materials can be extremely sensitive to electron beam damage during charge neutralization, leading to difficulties in determining depth scales and introducing unknown errors to secondary ion counts and their subsequent conversion to concentrations. This paper presents details regarding an investigation of the effects of electron beam exposure on a low-k material. These effects and their potential impact on SIMS data will be investigated using FT-IR, TOF-SIMS, AFM and stylus profilometry.
NASA Astrophysics Data System (ADS)
Pett-Ridge, J.; Finzi, J. A.; Capone, D. G.; Popa, R.; Nealson, K. H.; Ng, W.; Spormann, A. M.; Hutcheon, I. D.; Weber, P. K.
2007-12-01
Filamentous nitrogen fixing (diazotrophic) cyanobacteria are key players in global nutrient cycling, but the relationship between CO2- and N2-fixation and intercellular exchange of these elements remains poorly understood in many genera. These bacteria are faced with the challenge of isolating regions of N-fixation (O2 inhibited) and photosynthetic (O2 producing) activity. We used isotope labeling in conjunction with a high-resolution isotope and elemental mapping technique (NanoSIMS) to quantitatively describe 13C and 15N uptake and transport in two aquatic cyanobacteria grown on NaH13CO3 and 15N2. The technical challenges of tracing isotopes within individual bacteria can be overcome with high resolution Secondary Ion Mass Spectrometry (NanoSIMS). In NanoSIMS analysis, samples are sputtered with an energetic primary beam (Cs+, O-) liberating secondary ions that are separated by the mass spectrometer and detected in a suite of electron multipliers. Five isotopic species may be analyzed concurrently with spatial resolution as fine as 50nm. A high sensitivity isotope ratio 'map' can then be generated for the analyzed area. Using sequentially harvested cyanobacteria in conjunction with enriched H13CO3 and 15N2 incubations, we measured temporal enrichment patterns that evolve over the course of a day's growth and suggest tightly regulated changes in fixation kinetics. With a combination of TEM, SEM and NanoSIMS analyses, we also mapped the distribution of C, N and Mo (a critical nitrogenase co-factor) isotopes in intact cells. Our results suggest that NanoSIMS mapping of metal enzyme co-factors may be a powerful method of identifying physiological and morphological characteristics within individual bacterial cells, and could be used to provide a 3-dimensional context for more traditional analyses such as immunogold labeling. Finally, we resolved patterns of isotope enrichment at multiple spatial scales: sub-cellular variation, cell-cell differences along filaments, inter-species transfers (with Rhizobium epibionts), and within-cell depth profiles. Spatial enrichment patterns were correlated with morphological features evidenced in TEM images of microtomed filaments. These features indicate how 15N and 13C "hotspots" are dispersed throughout individual cells in different species, and may indicate isolated locations of increased N2 fixation, sites of amino acid/protein synthesis, or cyanophycin storage granules. This combination of Nano-Secondary Ion Mass Spectrometry (NanoSIMS) analysis and high resolution microscopy allows isotopic analysis to be linked to morphological features and holds great promise for fine-scale studies of bacteria metabolism.
Ghosal, Sutapa; Weber, Peter K.; Laskin, Alexander
2014-01-14
Knowledge of the spatially resolved composition of atmospheric particles is essential for differentiating between their surface versus bulk chemistry and understanding particle reactivity and the potential environmental impact. Here, we demonstrate the application of nanometer-scale secondary ion mass spectrometry (CAMECA NanoSIMS 50 ion probe) for 3D chemical imaging of individual atmospheric particles without any sample pre-treatment, such as sectioning of particles. Use of NanoSIMS depth profile analysis enables elemental mapping of particles with nanometer spatial resolution over a broad range of particle sizes. We have used this technique to probe the spatially resolved composition of ambient particles collected during amore » field campaign in Mexico City. Particles collected during this campaign have been extensively characterized in the past using other particle analysis techniques and hence offer a unique opportunity for exploring the utility of depth-resolved chemical imaging in ambient particle research. The particles that we examined in our study include those collected during a pollution episode related to urban waste incineration as well as background particles from the same location before the episode. Particles from the pollution episode show substantial intra-particle compositional variability typical of particles resulting from multiple emission sources. In contrast, the background particles have relatively homogeneous compositions with enhanced presence of nitrogen, oxygen, and chlorine at the particle surface. We also observed the surface enhancement of nitrogen and oxygen species is consistent with the presence of surface nitrates resulting from gas–particle heterogeneous interactions and is indicative of atmospheric ageing of the particles. The results presented here illustrate 3D characterization of ambient particles for insight into their chemical history.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghosal, Sutapa; Weber, Peter K.; Laskin, Alexander
2014-04-21
Knowledge of the spatially-resolved composition of atmospheric particles is essential for differentiating between their surface versus bulk chemistry, understanding particle reactivity and the potential environmental impact. We demonstrate the application of nanometer-scale secondary ion mass spectrometry (Cameca NanoSIMS 50 ion probe) for 3D chemical imaging of individual atmospheric particles without any sample pre-treatment, such as the sectioning of particles. Use of NanoSIMS depth profile analysis enables elemental mapping of particles with nanometer spatial resolution over a broad of range of particle sizes. We have used this technique to probe spatially resolved composition of ambient particles collected during a field campaignmore » in Mexico City. Particles collected during this campaign have been extensively characterized in the past using other particle analysis techniques and hence offer a unique opportunity for exploring the utility of depth resolved chemical imaging in ambient particle research. 1 Particles examined in this study include those collected during a pollution episode related to urban waste incineration as well as background particles from the same location prior to the episode. Particles from the pollution episode show substantial intra-particle compositional variability typical of particles resulting from multiple emission sources. In contrast, the background particles have relatively homogeneous compositions with enhanced presence of nitrogen, oxygen and chlorine at the particle surface. The observed surface enhancement of nitrogen and oxygen species is consistent with the presence of surface nitrates resulting from gas-particle heterogeneous interactions and is indicative of atmospheric ageing of the particles. The results presented here illustrate 3D characterization of ambient particles for insights into their chemical history.« less
Green-Saxena, A; Dekas, A E; Dalleska, N F; Orphan, V J
2014-01-01
Diverse associations between methanotrophic archaea (ANME) and sulfate-reducing bacterial groups (SRB) often co-occur in marine methane seeps; however, the ecophysiology of these different symbiotic associations has not been examined. Here, we applied a combination of molecular, geochemical and Fluorescence in situ hybridization (FISH) coupled to nanoscale secondary ion mass spectrometry (FISH-NanoSIMS) analyses of in situ seep sediments and methane-amended sediment incubations from diverse locations (Eel River Basin, Hydrate Ridge and Costa Rican Margin seeps) to investigate the distribution and physiology of a newly identified subgroup of the Desulfobulbaceae (seepDBB) found in consortia with ANME-2c archaea, and compared these with the more commonly observed associations between the same ANME partner and the Desulfobacteraceae (DSS). FISH analyses revealed aggregates of seepDBB cells in association with ANME-2 from both environmental samples and laboratory incubations that are distinct in their structure relative to co-occurring ANME/DSS consortia. ANME/seepDBB aggregates were most abundant in shallow sediment depths below sulfide-oxidizing microbial mats. Depth profiles of ANME/seepDBB aggregate abundance revealed a positive correlation with elevated porewater nitrate relative to ANME/DSS aggregates in all seep sites examined. This relationship with nitrate was supported by sediment microcosm experiments, in which the abundance of ANME/seepDBB was greater in nitrate-amended incubations relative to the unamended control. FISH-NanoSIMS additionally revealed significantly higher 15N-nitrate incorporation levels in individual aggregates of ANME/seepDBB relative to ANME/DSS aggregates from the same incubation. These combined results suggest that nitrate is a geochemical effector of ANME/seepDBB aggregate distribution, and provides a unique niche for these consortia through their utilization of a greater range of nitrogen substrates than the ANME/DSS. PMID:24008326
Mostafa, Alyaa; Agur, Wael; Abdel-All, Mohamed; Guerrero, Karen; Lim, Chi; Allam, Mohamed; Yousef, Mohamed; N'Dow, James; Abdel-fattah, Mohamed
2012-11-01
To compare the postoperative pain profile, peri-operative details, and short-term patient-reported and objective success rates of single-incision mini-slings (SIMS) versus standard mid-urethral slings (SMUS). In a multicentre prospective randomised trial in six UK centres in the period between October 2009 and October 2010, 137 women were randomised to either adjustable SIMS (Ajust®, C. R. Bard Inc., NJ, USA), performed under local anaesthesia as an opt-out policy (n=69), or SMUS (TVT-O™, Ethicon Inc., Somerville, USA) performed under general anaesthesia (n=68). Randomisation was done through number-allocation software and using telephone randomisation. Postoperative pain profile (primary outcome) was assessed on a ten-point visual analogue scale at fixed time-points. Pre- and post operatively (4-6 months) women completed symptom severity, urgency perception scale (UPS), quality of life and sexual function questionnaires. In addition, women completed a Patient Global Impression of Improvement Questionnaire and underwent a cough stress test at 4-6 months follow up. Sample size calculation was performed and data were analysed using SPSS 18. Descriptive analyses are given and between-group comparisons were performed using chi-square, Fischer exact test and Mann-Whitney test as appropriate. Significance level was set at 5%. Women in the SIMS Ajust® group had a significantly lower postoperative pain profile up to 4 weeks (p=<0.001, 95% CI 1.151, 2.480). There was no significant difference in peri-operative complications between groups. All 137 women completed the 4-6 months follow-up. Patient-reported and objective cure rates were not significantly different: 85.5% versus 91.2% (p=0.443) and 90% versus 97% (p=0.165) between the SIMS Ajust® and TVT-O™ groups respectively. There was a trend towards higher rates of de novo urgency or worsening of pre-existing urgency in the SIMS Ajust® group (21.7% versus 8.8%) but this did not reach statistical significance (p=0.063). Women in the SIMS Ajust® group had shorter hospital stay (median (IQR) 3.65 (2.49, 4.96)) compared to (4.42 (3.16, 5.56)) the TVT-O™ group 95% CI (-0.026, 1.326), with significantly earlier return to normal activities (p=0.025) and to work (p=0.006). The adjustable single-incision mini-sling (Ajust®) is associated with a significantly improved postoperative pain profile and earlier return to work when compared to standard mid-urethral slings (TVT-O™), with encouraging results in patient-reported and objective success rates at short-term follow-up. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
One- and two-dimensional dopant/carrier profiling for ULSI
NASA Astrophysics Data System (ADS)
Vandervorst, W.; Clarysse, T.; De Wolf, P.; Trenkler, T.; Hantschel, T.; Stephenson, R.; Janssens, T.
1998-11-01
Dopant/carrier profiles constitute the basis of the operation of a semiconductor device and thus play a decisive role in the performance of a transistor and are subjected to the same scaling laws as the other constituents of a modern semiconductor device and continuously evolve towards shallower and more complex configurations. This evolution has increased the demands on the profiling techniques in particular in terms of resolution and quantification such that a constant reevaluation and improvement of the tools is required. As no single technique provides all the necessary information (dopant distribution, electrical activation,..) with the requested spatial and depth resolution, the present paper attempts to provide an assessment of those tools which can be considered as the main metrology technologies for ULSI-applications. For 1D-dopant profiling secondary ion mass spectrometry (SIMS) has progressed towards a generally accepted tool meeting the requirements. For 1D-carrier profiling spreading resistance profiling and microwave surface impedance profiling are envisaged as the best choices but extra developments are required to promote them to routinely applicable methods. As no main metrology tool exist for 2D-dopant profiling, main emphasis is on 2D-carrier profiling tools based on scanning probe microscopy. Scanning spreading resistance (SSRM) and scanning capacitance microscopy (SCM) are the preferred methods although neither of them already meets all the requirements. Complementary information can be extracted from Nanopotentiometry which samples the device operation in more detail. Concurrent use of carrier profiling tools, Nanopotentiometry, analysis of device characteristics and simulations is required to provide a complete characterization of deep submicron devices.
High temperature reaction between sea salt deposit and (U,Zr)O2 simulated corium debris
NASA Astrophysics Data System (ADS)
Takano, Masahide; Nishi, Tsuyoshi
2013-11-01
In order to clarify the possible impacts of seawater injection on the chemical and physical state of the corium debris formed in the severe accident at Fukushima Daiichi Nuclear Power Plants, the high temperature reaction between sea salt deposit and (U,Zr)O2 simulated corium debris (sim-debris) was examined in the temperature range from 1088 to 1668 K. A dense layer of calcium and sodium uranate formed on the surface of a sim-debris pellet at 1275 K under airflow, with the thickness of over 50 μm. When the oxygen partial pressure is low, calcium is likely to dissolve into the cubic sim-debris phase to form solid solution (Ca,U,Zr)O2+x. The diffusion depth was 5-6 μm from the surface, subjected to 1275 K for 12 h. The crystalline MgO remains affixed on the surface as the main residue of salt components. A part of it can also dissolve into the sim-debris.
NASA Astrophysics Data System (ADS)
Chandel, Tarun; Halaszova, Sona; Prochazka, Michal; Hasko, Daniel; Velic, Dusan; Thakur, Vikas; Dwivedi, Shailendra Kumar; Zaman, M. Buhanuz; Rajaram, Poolla
2018-05-01
Nanocrystalline thin films of Cu2ZnSnS4 (CZTS) were grown on the glass substrates using the spray pyrolysis technique. The films were grown at a substrate temperature of 300 °C after which they were annealed at 350 °C in vacuum. X-ray diffraction (XRD) studies showed that the films crystallized in the kesterite structure. Energy dispersive analysis of X-rays (EDAX) studies showed that the films possess the desired stoichiometry i.e. the proportion of Cu:Zn:Sn:S in the CZTS solid solution is close to 2:1:1:4. Secondary Ions Mass Spectroscopy (SIMS) depth profiling confirmed the uniformity in elemental composition along the depth of the films. SEM studies showed that the films are covered with CZTS particles forming sheet like structures. AFM studies show that the size of the particles on the surface of the films is around 10-15 nm. UV-VIS-NIR transmission spectra were used to determine the optical band gap of the CZTS films which was found to be around 1.55eV.
Motion of W and He atoms during formation of W fuzz
NASA Astrophysics Data System (ADS)
Doerner, R. P.; Nishijima, D.; Krasheninnikov, S. I.; Schwarz-Selinger, T.; Zach, M.
2018-06-01
Measurements are conducted to identify the motion of tungsten and helium atoms during the formation of tungsten fuzz. In a first series of experiments the mobility of helium within the growing fuzz was measured by adding 3He to the different stages of plasma exposure under conditions that promoted tungsten fuzz growth. Ion beam analysis was used to quantify the amount of 3He remaining in the samples following the plasma exposure. The results indicate that the retention of helium in bubbles within tungsten is a dynamic process with direct implantation rather than diffusion into the bubbles, best describing the motion of the helium atoms. In the second experiment, an isotopically enriched layer of tungsten (~92.99% 182W) is deposited on the surface of a bulk tungsten sample with the natural abundance of the isotopes. This sample is then exposed to helium plasma at the conditions necessary to support the formation of tungsten ‘fuzz’. Depth profiles of the concentration of each of the tungsten isotopes are obtained using secondary ion mass spectrometry (SIMS) before and after the plasma exposure. The depth profiles clearly show mixing of tungsten atoms from the bulk sample toward the surface of the fuzz. This supports a physical picture of the dynamic behavior of helium bubbles which, also, causes an enhanced mixing of tungsten atoms.
Motion of W and He atoms during formation of W fuzz
Doerner, R. P.; Nishijima, D.; Krasheninnikov, S. I.; ...
2018-04-11
Measurements are conducted to identify the motion of tungsten and helium atoms during the formation of tungsten fuzz. In a first series of experiments the mobility of helium within the growing fuzz was measured by adding 3He to the different stages of plasma exposure under conditions that promoted tungsten fuzz growth. Ion beam analysis was used to quantify the amount of 3He remaining in the samples following the plasma exposure. The results indicate that the retention of helium in bubbles within tungsten is a dynamic process with direct implantation rather than diffusion into the bubbles, best describing the motion ofmore » the helium atoms. In the second experiment, an isotopically enriched layer of tungsten (~92.99% 182W) is deposited on the surface of a bulk tungsten sample with the natural abundance of the isotopes. This sample is then exposed to helium plasma at the conditions necessary to support the formation of tungsten 'fuzz'. Depth profiles of the concentration of each of the tungsten isotopes are obtained using secondary ion mass spectrometry (SIMS) before and after the plasma exposure. The depth profiles clearly show mixing of tungsten atoms from the bulk sample toward the surface of the fuzz. Lastly, this supports a physical picture of the dynamic behavior of helium bubbles which, also, causes an enhanced mixing of tungsten atoms.« less
Shilling Attacks Detection in Recommender Systems Based on Target Item Analysis
Zhou, Wei; Wen, Junhao; Koh, Yun Sing; Xiong, Qingyu; Gao, Min; Dobbie, Gillian; Alam, Shafiq
2015-01-01
Recommender systems are highly vulnerable to shilling attacks, both by individuals and groups. Attackers who introduce biased ratings in order to affect recommendations, have been shown to negatively affect collaborative filtering (CF) algorithms. Previous research focuses only on the differences between genuine profiles and attack profiles, ignoring the group characteristics in attack profiles. In this paper, we study the use of statistical metrics to detect rating patterns of attackers and group characteristics in attack profiles. Another question is that most existing detecting methods are model specific. Two metrics, Rating Deviation from Mean Agreement (RDMA) and Degree of Similarity with Top Neighbors (DegSim), are used for analyzing rating patterns between malicious profiles and genuine profiles in attack models. Building upon this, we also propose and evaluate a detection structure called RD-TIA for detecting shilling attacks in recommender systems using a statistical approach. In order to detect more complicated attack models, we propose a novel metric called DegSim’ based on DegSim. The experimental results show that our detection model based on target item analysis is an effective approach for detecting shilling attacks. PMID:26222882
Look@NanoSIMS--a tool for the analysis of nanoSIMS data in environmental microbiology.
Polerecky, Lubos; Adam, Birgit; Milucka, Jana; Musat, Niculina; Vagner, Tomas; Kuypers, Marcel M M
2012-04-01
We describe an open-source freeware programme for high throughput analysis of nanoSIMS (nanometre-scale secondary ion mass spectrometry) data. The programme implements basic data processing and analytical functions, including display and drift-corrected accumulation of scanned planes, interactive and semi-automated definition of regions of interest (ROIs), and export of the ROIs' elemental and isotopic composition in graphical and text-based formats. Additionally, the programme offers new functions that were custom-designed to address the needs of environmental microbiologists. Specifically, it allows manual and automated classification of ROIs based on the information that is derived either from the nanoSIMS dataset itself (e.g. from labelling achieved by halogen in situ hybridization) or is provided externally (e.g. as a fluorescence in situ hybridization image). Moreover, by implementing post-processing routines coupled to built-in statistical tools, the programme allows rapid synthesis and comparative analysis of results from many different datasets. After validation of the programme, we illustrate how these new processing and analytical functions increase flexibility, efficiency and depth of the nanoSIMS data analysis. Through its custom-made and open-source design, the programme provides an efficient, reliable and easily expandable tool that can help a growing community of environmental microbiologists and researchers from other disciplines process and analyse their nanoSIMS data. © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Lloyd, Alexander S.; Ruprecht, Philipp; Hauri, Erik H.; Rose, William; Gonnermann, Helge M.; Plank, Terry
2014-08-01
The explosivity of volcanic eruptions is governed in part by the rate at which magma ascends and degasses. Because the time scales of eruptive processes can be exceptionally fast relative to standard geochronometers, magma ascent rate remains difficult to quantify. Here we use as a chronometer concentration gradients of volatile species along open melt embayments within olivine crystals. Continuous degassing of the external melt during magma ascent results in diffusion of volatile species from embayment interiors to the bubble located at their outlets. The novel aspect of this study is the measurement of concentration gradients in five volatile elements (CO2, H2O, S, Cl, F) at fine-scale (5-10 μm) using the NanoSIMS. The wide range in diffusivity and solubility of these different volatiles provides multiple constraints on ascent timescales over a range of depths. We focus on four 100-200 μm, olivine-hosted embayments erupted on October 17, 1974 during the sub-Plinian eruption of Volcán de Fuego. H2O, CO2, and S all decrease toward the embayment outlet bubble, while F and Cl increase or remain roughly constant. Compared to an extensive melt inclusion suite from the same day of the eruption, the embayments have lost both H2O and CO2 throughout the entire length of the embayment. We fit the profiles with a 1-D numerical diffusion model that allows varying diffusivities and external melt concentrations as a function of pressure. Assuming a constant decompression rate from the magma storage region at approximately 220 MPa to the surface, H2O, CO2 and S profiles for all embayments can be fit with a relatively narrow range in decompression rates of 0.3-0.5 MPa/s, equivalent to 11-17 m/s ascent velocity and an 8 to 12 minute duration of magma ascent from ~ 10 km depth. A two stage decompression model takes advantage of the different depth ranges over which CO2 and H2O degas, and produces good fits given an initial stage of slow decompression (0.05-0.3 MPa/s) at high pressure (> 145 MPa), with similar decompression rates to the single-stage model for the shallower stage. The magma ascent rates reported here are among the first for explosive basaltic eruptions and demonstrate the potential of the embayment method for quantifying magmatic timescales associated with eruptions of different vigor.
Li, Yong; Ruan, Qiang; Li, Yanli; Ye, Guozhu; Lu, Xin; Lin, Xiaohui; Xu, Guowang
2012-09-14
Non-targeted metabolic profiling is the most widely used method for metabolomics. In this paper, a novel approach was established to transform a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ion monitoring (RTL-GC/MS-SIM). To achieve this transformation, an algorithm based on the automated mass spectral deconvolution and identification system (AMDIS), GC/MS raw data and a bi-Gaussian chromatographic peak model was developed. The established GC/MS-SIM method was compared with GC/MS-full scan (the total ion current and extracted ion current, TIC and EIC) methods, it was found that for a typical tobacco leaf extract, 93% components had their relative standard deviations (RSDs) of relative peak areas less than 20% by the SIM method, while 88% by the EIC method and 81% by the TIC method. 47.3% components had their linear correlation coefficient higher than 0.99, compared with 5.0% by the EIC and 6.2% by TIC methods. Multivariate analysis showed the pooled quality control samples clustered more tightly using the developed method than using GC/MS-full scan methods, indicating a better data quality. With the analysis of the variance of the tobacco samples from three different planting regions, 167 differential components (p<0.05) were screened out using the RTL-GC/MS-SIM method, but 151 and 131 by the EIC and TIC methods, respectively. The results show that the developed method not only has a higher sensitivity, better linearity and data quality, but also does not need complicated peak alignment among different samples. It is especially suitable for the screening of differential components in the metabolic profiling investigation. Copyright © 2012 Elsevier B.V. All rights reserved.
ChromBiSim: Interactive chromatin biclustering using a simple approach.
Noureen, Nighat; Zohaib, Hafiz Muhammad; Qadir, Muhammad Abdul; Fazal, Sahar
2017-10-01
Combinatorial patterns of histone modifications sketch the epigenomic locale. Specific positions of these modifications in the genome are marked by the presence of such signals. Various methods highlight such patterns on global scale hence missing the local patterns which are the actual hidden combinatorics. We present ChromBiSim, an interactive tool for mining subsets of modifications from epigenomic profiles. ChromBiSim efficiently extracts biclusters with their genomic locations. It is the very first user interface based and multiple cell type handling tool for decoding the interplay of subsets of histone modifications combinations along their genomic locations. It displays the results in the forms of charts and heat maps in accordance with saving them in files which could be used for post analysis. ChromBiSim tested on multiple cell types produced in total 803 combinatorial patterns. It could be used to highlight variations among diseased versus normal cell types of any species. ChromBiSim is available at (http://sourceforge.net/projects/chrombisim) in C-sharp and python languages. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ievlev, Anton V.; Belianinov, Alexei; Jesse, Stephen
Time of flight secondary ion mass spectrometry (ToF SIMS) is one of the most powerful characterization tools allowing imaging of the chemical properties of various systems and materials. It allows precise studies of the chemical composition with sub-100-nm lateral and nanometer depth spatial resolution. However, comprehensive interpretation of ToF SIMS results is challengeable, because of the data volume and its multidimensionality. Furthermore, investigation of the samples with pronounced topographical features are complicated by the spectral shift. In this work we developed approach for the comprehensive ToF SIMS data interpretation based on the data analytics and automated extraction of the samplemore » topography based on time of flight shift. We further applied this approach to investigate correlation between biological function and chemical composition in Arabidopsis roots.« less
Ievlev, Anton V.; Belianinov, Alexei; Jesse, Stephen; ...
2017-12-06
Time of flight secondary ion mass spectrometry (ToF SIMS) is one of the most powerful characterization tools allowing imaging of the chemical properties of various systems and materials. It allows precise studies of the chemical composition with sub-100-nm lateral and nanometer depth spatial resolution. However, comprehensive interpretation of ToF SIMS results is challengeable, because of the data volume and its multidimensionality. Furthermore, investigation of the samples with pronounced topographical features are complicated by the spectral shift. In this work we developed approach for the comprehensive ToF SIMS data interpretation based on the data analytics and automated extraction of the samplemore » topography based on time of flight shift. We further applied this approach to investigate correlation between biological function and chemical composition in Arabidopsis roots.« less
Zhao, Ming; Zhang, Han; Li, Yu; Ashok, Amit; Liang, Rongguang; Zhou, Weibin; Peng, Leilei
2014-01-01
In vivo fluorescent cellular imaging of deep internal organs is highly challenging, because the excitation needs to penetrate through strong scattering tissue and the emission signal is degraded significantly by photon diffusion induced by tissue-scattering. We report that by combining two-photon Bessel light-sheet microscopy with nonlinear structured illumination microscopy (SIM), live samples up to 600 microns wide can be imaged by light-sheet microscopy with 500 microns penetration depth, and diffused background in deep tissue light-sheet imaging can be reduced to obtain clear images at cellular resolution in depth beyond 200 microns. We demonstrate in vivo two-color imaging of pronephric glomeruli and vasculature of zebrafish kidney, whose cellular structures located at the center of the fish body are revealed in high clarity by two-color two-photon Bessel light-sheet SIM. PMID:24876996
NASA Astrophysics Data System (ADS)
Parker, Jay; Donnellan, Andrea; Glasscoe, Margaret; Fox, Geoffrey; Wang, Jun; Pierce, Marlon; Ma, Yu
2015-08-01
High-resolution maps of earth surface deformation are available in public archives for scientific interpretation, but are primarily available as bulky downloads on the internet. The NASA uninhabited aerial vehicle synthetic aperture radar (UAVSAR) archive of airborne radar interferograms delivers very high resolution images (approximately seven meter pixels) making remote handling of the files that much more pressing. Data exploration requiring data selection and exploratory analysis has been tedious. QuakeSim has implemented an archive of UAVSAR data in a web service and browser system based on GeoServer (http://geoserver.org). This supports a variety of services that supply consistent maps, raster image data and geographic information systems (GIS) objects including standard earthquake faults. Browsing the database is supported by initially displaying GIS-referenced thumbnail images of the radar displacement maps. Access is also provided to image metadata and links for full file downloads. One of the most widely used features is the QuakeSim line-of-sight profile tool, which calculates the radar-observed displacement (from an unwrapped interferogram product) along a line specified through a web browser. Displacement values along a profile are updated to a plot on the screen as the user interactively redefines the endpoints of the line and the sampling density. The profile and also a plot of the ground height are available as CSV (text) files for further examination, without any need to download the full radar file. Additional tools allow the user to select a polygon overlapping the radar displacement image, specify a downsampling rate and extract a modest sized grid of observations for display or for inversion, for example, the QuakeSim simplex inversion tool which estimates a consistent fault geometry and slip model.
Ga + TOF-SIMS lineshape analysis for resolution enhancement of MALDI MS spectra of a peptide mixture
NASA Astrophysics Data System (ADS)
Malyarenko, D. I.; Chen, H.; Wilkerson, A. L.; Tracy, E. R.; Cooke, W. E.; Manos, D. M.; Sasinowski, M.; Semmes, O. J.
2004-06-01
The use of mass spectrometry to obtain molecular profiles indicative of alteration of concentrations of peptides in body fluids is currently the subject of intense investigation. For surface-based time-of-flight mass spectrometry the reliability and specificity of such profiling methods depend both on the resolution of the measuring instrument and on the preparation of samples. The present work is a part of a program to use Ga + beam TOF-SIMS alone, and as an adjunct to MALDI, in the development of reliable protein and peptide markers for diseases. Here, we describe techniques to prepare samples of relatively high-mass peptides, which serve as calibration standards and proxies for biomarkers. These are: Arg8-vasopressin, human angiotensin II, and somatostatin. Their TOF-SIMS spectra show repeatable characteristic features, with mass resolution exceeding 2000, including parent peaks and chemical adducts. The lineshape analysis for high-resolution parent peaks is shown to be useful for filter construction and deconvolution of inferior resolution SELDI-TOF spectra of calibration peptide mixture.
Development and Validation of a Monte Carlo Simulation Tool for Multi-Pinhole SPECT
Mok, Greta S. P.; Du, Yong; Wang, Yuchuan; Frey, Eric C.; Tsui, Benjamin M. W.
2011-01-01
Purpose In this work, we developed and validated a Monte Carlo simulation (MCS) tool for investigation and evaluation of multi-pinhole (MPH) SPECT imaging. Procedures This tool was based on a combination of the SimSET and MCNP codes. Photon attenuation and scatter in the object, as well as penetration and scatter through the collimator detector, are modeled in this tool. It allows accurate and efficient simulation of MPH SPECT with focused pinhole apertures and user-specified photon energy, aperture material, and imaging geometry. The MCS method was validated by comparing the point response function (PRF), detection efficiency (DE), and image profiles obtained from point sources and phantom experiments. A prototype single-pinhole collimator and focused four- and five-pinhole collimators fitted on a small animal imager were used for the experimental validations. We have also compared computational speed among various simulation tools for MPH SPECT, including SimSET-MCNP, MCNP, SimSET-GATE, and GATE for simulating projections of a hot sphere phantom. Results We found good agreement between the MCS and experimental results for PRF, DE, and image profiles, indicating the validity of the simulation method. The relative computational speeds for SimSET-MCNP, MCNP, SimSET-GATE, and GATE are 1: 2.73: 3.54: 7.34, respectively, for 120-view simulations. We also demonstrated the application of this MCS tool in small animal imaging by generating a set of low-noise MPH projection data of a 3D digital mouse whole body phantom. Conclusions The new method is useful for studying MPH collimator designs, data acquisition protocols, image reconstructions, and compensation techniques. It also has great potential to be applied for modeling the collimator-detector response with penetration and scatter effects for MPH in the quantitative reconstruction method. PMID:19779896
Hematologic and biochemical characteristics of stranded green sea turtles.
March, Duane T; Vinette-Herrin, Kimberly; Peters, Andrew; Ariel, Ellen; Blyde, David; Hayward, Doug; Christidis, Les; Kelaher, Brendan P
2018-05-01
To improve understanding of pathophysiologic processes occurring in green sea turtles ( Chelonia mydas) stranded along the east coast of Australia, we retrospectively examined the hematologic and biochemical blood parameters of 127 green turtles admitted to 2 rehabilitation facilities, Dolphin Marine Magic (DMM) and Taronga Zoo (TZ), between 2002 and 2016. The predominant size class presented was small immature animals (SIM), comprising 88% and 69% of admissions to DMM and TZ, respectively. Significant differences in blood profiles were noted between facility, size, and outcome. Elevated levels of aspartate aminotransferase (AST) and heterophils were poor prognostic indicators in animals from TZ, but not DMM. SIM animals at both institutions had lower protein levels than large older (LO) animals. SIM animals at DMM also had lower hematocrit and monocyte concentration; SIM animals at TZ had lower heterophil counts. Urea was measured for 27 SIM animals from TZ, but the urea-to-uric acid ratio was not prognostically useful. Strong correlations were seen between AST and glutamate dehydrogenase (GDH; r = 0.68) and uric acid and bile acids ( r = 0.72) in the 45 SIM animals from DMM in which additional analytes were measured. χ 2 contingency tests showed that the most recently published reference intervals were not prognostically useful. A paired t-test showed that protein levels rose and heterophil numbers fell in the 15 SIM animals from TZ during the rehabilitation process. Our results indicate that further work is required to identify reliable prognostic biomarkers for green turtles.
TOFSIMS-P: a web-based platform for analysis of large-scale TOF-SIMS data.
Yun, So Jeong; Park, Ji-Won; Choi, Il Ju; Kang, Byeongsoo; Kim, Hark Kyun; Moon, Dae Won; Lee, Tae Geol; Hwang, Daehee
2011-12-15
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been a useful tool to profile secondary ions from the near surface region of specimens with its high molecular specificity and submicrometer spatial resolution. However, the TOF-SIMS analysis of even a moderately large size of samples has been hampered due to the lack of tools for automatically analyzing the huge amount of TOF-SIMS data. Here, we present a computational platform to automatically identify and align peaks, find discriminatory ions, build a classifier, and construct networks describing differential metabolic pathways. To demonstrate the utility of the platform, we analyzed 43 data sets generated from seven gastric cancer and eight normal tissues using TOF-SIMS. A total of 87 138 ions were detected from the 43 data sets by TOF-SIMS. We selected and then aligned 1286 ions. Among them, we found the 66 ions discriminating gastric cancer tissues from normal ones. Using these 66 ions, we then built a partial least square-discriminant analysis (PLS-DA) model resulting in a misclassification error rate of 0.024. Finally, network analysis of the 66 ions showed disregulation of amino acid metabolism in the gastric cancer tissues. The results show that the proposed framework was effective in analyzing TOF-SIMS data from a moderately large size of samples, resulting in discrimination of gastric cancer tissues from normal tissues and identification of biomarker candidates associated with the amino acid metabolism.
Sisco, Edward; Demoranville, Leonard T; Gillen, Greg
2013-09-10
The feasibility of using C60(+) cluster primary ion bombardment secondary ion mass spectrometry (C60(+) SIMS) for the analysis of the chemical composition of fingerprints is evaluated. It was found that C60(+) SIMS could be used to detect and image the spatial localization of a number of sebaceous and eccrine components in fingerprints. These analyses were also found to not be hindered by the use of common latent print powder development techniques. Finally, the ability to monitor the depth distribution of fingerprint constituents was found to be possible - a capability which has not been shown using other chemical imaging techniques. This paper illustrates a number of strengths and potential weaknesses of C60(+) SIMS as an additional or complimentary technique for the chemical analysis of fingerprints. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Low-temperature lithium diffusion in simulated high-level boroaluminosilicate nuclear waste glasses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neeway, James J.; Kerisit, Sebastien N.; Gin, Stephane
2014-12-01
Ion exchange is recognized as an integral, if underrepresented, mechanism influencing glass corrosion. However, due to the formation of various alteration layers in the presence of water, it is difficult to conclusively deconvolute the mechanisms of ion exchange from other processes occurring simultaneously during corrosion. In this work, an operationally inert non-aqueous solution was used as an alkali source material to isolate ion exchange and study the solid-state diffusion of lithium. Specifically, the experiments involved contacting glass coupons relevant to the immobilization of high-level nuclear waste, SON68 and CJ-6, which contained Li in natural isotope abundance, with a non-aqueous solutionmore » of 6LiCl dissolved in dimethyl sulfoxide at 90 °C for various time periods. The depth profiles of major elements in the glass coupons were measured using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Lithium interdiffusion coefficients, D Li, were then calculated based on the measured depth profiles. The results indicate that the penetration of 6Li is rapid in both glasses with the simplified CJ-6 glass (D 6Li ≈ 4.0-8.0 × 10 -21 m 2/s) exhibiting faster exchange than the more complex SON68 glass (D Li ≈ 2.0-4.0 × 10 -21 m 2/s). Additionally, sodium ions present in the glass were observed to participate in ion exchange reactions; however, different diffusion coefficients were necessary to fit the diffusion profiles of the two alkali ions. Implications of the diffusion coefficients obtained in the absence of alteration layers to the long-term performance of nuclear waste glasses in a geological repository system are also discussed.« less
SimExTargId: A comprehensive package for real-time LC-MS data acquisition and analysis.
Edmands, William M B; Hayes, Josie; Rappaport, Stephen M
2018-05-22
Liquid chromatography mass spectrometry (LC-MS) is the favored method for untargeted metabolomic analysis of small molecules in biofluids. Here we present SimExTargId, an open-source R package for autonomous analysis of metabolomic data and real-time observation of experimental runs. This simultaneous, fully automated and multi-threaded (optional) package is a wrapper for vendor-independent format conversion (ProteoWizard), xcms- and CAMERA- based peak-picking, MetMSLine-based pre-processing and covariate-based statistical analysis. Users are notified of detrimental instrument drift or errors by email. Also included are two shiny applications, targetId for real-time MS2 target identification, and peakMonitor to monitor targeted metabolites. SimExTargId is publicly available under GNU LGPL v3.0 license at https://github.com/JosieLHayes/simExTargId, which includes a vignette with example data. SimExTargId should be installed on a dedicated data-processing workstation or server that is networked to the LC-MS platform to facilitate MS1 profiling of metabolomic data. josie.hayes@berkeley.edu. Supplementary data are available at Bioinformatics online.
Multi-scale modelling to evaluate building energy consumption at the neighbourhood scale.
Mauree, Dasaraden; Coccolo, Silvia; Kaempf, Jérôme; Scartezzini, Jean-Louis
2017-01-01
A new methodology is proposed to couple a meteorological model with a building energy use model. The aim of such a coupling is to improve the boundary conditions of both models with no significant increase in computational time. In the present case, the Canopy Interface Model (CIM) is coupled with CitySim. CitySim provides the geometrical characteristics to CIM, which then calculates a high resolution profile of the meteorological variables. These are in turn used by CitySim to calculate the energy flows in an urban district. We have conducted a series of experiments on the EPFL campus in Lausanne, Switzerland, to show the effectiveness of the coupling strategy. First, measured data from the campus for the year 2015 are used to force CIM and to evaluate its aptitude to reproduce high resolution vertical profiles. Second, we compare the use of local climatic data and data from a meteorological station located outside the urban area, in an evaluation of energy use. In both experiments, we demonstrate the importance of using in building energy software, meteorological variables that account for the urban microclimate. Furthermore, we also show that some building and urban forms are more sensitive to the local environment.
Multi-scale modelling to evaluate building energy consumption at the neighbourhood scale
Coccolo, Silvia; Kaempf, Jérôme; Scartezzini, Jean-Louis
2017-01-01
A new methodology is proposed to couple a meteorological model with a building energy use model. The aim of such a coupling is to improve the boundary conditions of both models with no significant increase in computational time. In the present case, the Canopy Interface Model (CIM) is coupled with CitySim. CitySim provides the geometrical characteristics to CIM, which then calculates a high resolution profile of the meteorological variables. These are in turn used by CitySim to calculate the energy flows in an urban district. We have conducted a series of experiments on the EPFL campus in Lausanne, Switzerland, to show the effectiveness of the coupling strategy. First, measured data from the campus for the year 2015 are used to force CIM and to evaluate its aptitude to reproduce high resolution vertical profiles. Second, we compare the use of local climatic data and data from a meteorological station located outside the urban area, in an evaluation of energy use. In both experiments, we demonstrate the importance of using in building energy software, meteorological variables that account for the urban microclimate. Furthermore, we also show that some building and urban forms are more sensitive to the local environment. PMID:28880883
Incorporating evolution of transcription factor binding sites into annotated alignments.
Bais, Abha S; Grossmann, Stefen; Vingron, Martin
2007-08-01
Identifying transcription factor binding sites (TFBSs) is essential to elucidate putative regulatory mechanisms. A common strategy is to combine cross-species conservation with single sequence TFBS annotation to yield "conserved TFBSs". Most current methods in this field adopt a multi-step approach that segregates the two aspects. Again, it is widely accepted that the evolutionary dynamics of binding sites differ from those of the surrounding sequence. Hence, it is desirable to have an approach that explicitly takes this factor into account. Although a plethora of approaches have been proposed for the prediction of conserved TFBSs, very few explicitly model TFBS evolutionary properties, while additionally being multi-step. Recently, we introduced a novel approach to simultaneously align and annotate conserved TFBSs in a pair of sequences. Building upon the standard Smith-Waterman algorithm for local alignments, SimAnn introduces additional states for profiles to output extended alignments or annotated alignments. That is, alignments with parts annotated as gaplessly aligned TFBSs (pair-profile hits)are generated. Moreover,the pair- profile related parameters are derived in a sound statistical framework. In this article, we extend this approach to explicitly incorporate evolution of binding sites in the SimAnn framework. We demonstrate the extension in the theoretical derivations through two position-specific evolutionary models, previously used for modelling TFBS evolution. In a simulated setting, we provide a proof of concept that the approach works given the underlying assumptions,as compared to the original work. Finally, using a real dataset of experimentally verified binding sites in human-mouse sequence pairs,we compare the new approach (eSimAnn) to an existing multi-step tool that also considers TFBS evolution. Although it is widely accepted that binding sites evolve differently from the surrounding sequences, most comparative TFBS identification methods do not explicitly consider this.Additionally, prediction of conserved binding sites is carried out in a multi-step approach that segregates alignment from TFBS annotation. In this paper, we demonstrate how the simultaneous alignment and annotation approach of SimAnn can be further extended to incorporate TFBS evolutionary relationships. We study how alignments and binding site predictions interplay at varying evolutionary distances and for various profile qualities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Ke; Zhang, Yanwen; Zhu, Zihua
Accurate information of electronic stopping power is fundamental for broad advances in electronic industry, space exploration, national security, and sustainable energy technologies. The Stopping and Range of Ions in Matter (SRIM) code has been widely applied to predict stopping powers and ion distributions for decades. Recent experimental results have, however, shown considerable errors in the SRIM predictions for stopping of heavy ions in compounds containing light elements, indicating an urgent need to improve current stopping power models. The electronic stopping powers of 35Cl, 80Br, 127I, and 197Au ions are experimentally determined in two important functional materials, SiC and SiO2, frommore » tens to hundreds keV/u based on a single ion technique. By combining with the reciprocity theory, new electronic stopping powers are suggested in a region from 0 to 15 MeV, where large deviations from SRIM predictions are observed. For independent experimental validation of the electronic stopping powers we determined, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC with energies from 700 keV to 15 MeV. The measured ion distributions from both RBS and SIMS are considerably deeper (up to ~30%) than the predictions from the commercial SRIM code. In comparison, the new electronic stopping power values are utilized in a modified TRIM-85 (the original version of the SRIM) code, M-TRIM, to predict ion distributions, and the results are in good agreement with the experimentally measured ion distributions.« less
NASA Astrophysics Data System (ADS)
Tulsyan, Gaurav
Doping profiles are engineered to manipulate device properties and to determine electrical performances of microelectronic devices frequently. To support engineering studies afterward, essential information is usually required from physically characterized doping profiles. Secondary Ion Mass Spectrometry (SIMS), Spreading Resistance Profiling (SRP) and Electrochemical Capacitance Voltage (ECV) profiling are standard techniques for now to map profile. SIMS yields a chemical doping profile via ion sputtering process and owns a better resolution, whereas ECV and SRP produce an electrical doping profile detecting free carriers in microelectronic devices. The major difference between electrical and chemical doping profiles is at heavily doped regions greater than 1020 atoms/cm3. At the profile region over the solubility limit, inactive dopants induce a flat plateau and detected by electrical measurements only. Destructive techniques are usually designed as stand-alone systems to study impurities. For an in-situ process control purpose, non-contact methods, such as ellipsometry and non-contact capacitance voltage (CV) techniques are current under development. In this theses work, terahertz time domain spectroscopy (THz-TDS) is utilized to achieve electrical doping profile in both destructive and non-contact manners. In recent years the Terahertz group at Rochester Institute Technology developed several techniques that use terahertz pulses to non-destructively map doping profiles. In this thesis, we study a destructive but potentially higher resolution version of the terahertz based approach to map the profile of activated dopants and augment the non-destructive approaches already developed. The basic idea of the profile mapping approach developed in this MS thesis is to anodize, and thus oxidize to silicon dioxide, thin layers (down to below 10 nm) of the wafer with the doping profile to be mapped. Since the dopants atoms and any free carriers in the silicon oxide thin film are invisible to the terahertz probe this anodization step very effectively removes a 'thin slice' from the doping profile to be mapped. By iterating between anodization and terahertz measurements that detect only the 'remaining' non-oxidized portion of the doping profile one can re-construct the doping profile with significantly higher precision compared to what is possible by only a single non-destructive measurement of the un-anodized profile as used in the non-destructive version of our technique. In this MS thesis we explore all aspects of this anodization based variation of doping profile mapping using free space terahertz pulses. This includes a study of silicon dioxide thin film growth using a room temperature electrochemical oxidation process. Etching procedures providing the option to remove between successive anodization and terahertz measurement steps. THz-TDS measurements of successively anodized profiles will be compared with sheet resistance and SIMS measurements to benchmark and improve the new technique.
GPCR-ModSim: A comprehensive web based solution for modeling G-protein coupled receptors
Esguerra, Mauricio; Siretskiy, Alexey; Bello, Xabier; Sallander, Jessica; Gutiérrez-de-Terán, Hugo
2016-01-01
GPCR-ModSim (http://open.gpcr-modsim.org) is a centralized and easy to use service dedicated to the structural modeling of G-protein Coupled Receptors (GPCRs). 3D molecular models can be generated from amino acid sequence by homology-modeling techniques, considering different receptor conformations. GPCR-ModSim includes a membrane insertion and molecular dynamics (MD) equilibration protocol, which can be used to refine the generated model or any GPCR structure uploaded to the server, including if desired non-protein elements such as orthosteric or allosteric ligands, structural waters or ions. We herein revise the main characteristics of GPCR-ModSim and present new functionalities. The templates used for homology modeling have been updated considering the latest structural data, with separate profile structural alignments built for inactive, partially-active and active groups of templates. We have also added the possibility to perform multiple-template homology modeling in a unique and flexible way. Finally, our new MD protocol considers a series of distance restraints derived from a recently identified conserved network of helical contacts, allowing for a smoother refinement of the generated models which is particularly advised when there is low homology to the available templates. GPCR- ModSim has been tested on the GPCR Dock 2013 competition with satisfactory results. PMID:27166369
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ingram, Jani Cheri; Lehman, Richard Michael; Bauer, William Francis
We report the use of a surface analysis approach, static secondary ion mass spectrometry (SIMS) equipped with a molecular (ReO4-) ion primary beam, to analyze the surface of intact microbial cells. SIMS spectra of 28 microorganisms were compared to fatty acid profiles determined by gas chromatographic analysis of transesterfied fatty acids extracted from the same organisms. The results indicate that surface bombardment using the molecular primary beam cleaved the ester linkage characteristic of bacteria at the glycerophosphate backbone of the phospholipid components of the cell membrane. This cleavage enables direct detection of the fatty acid conjugate base of intact microorganismsmore » by static SIMS. The limit of detection for this approach is approximately 107 bacterial cells/cm2. Multivariate statistical methods were applied in a graded approach to the SIMS microbial data. The results showed that the full data set could initially be statistically grouped based upon major differences in biochemical composition of the cell wall. The gram-positive bacteria were further statistically analyzed, followed by final analysis of a specific bacterial genus that was successfully grouped by species. Additionally, the use of SIMS to detect microbes on mineral surfaces is demonstrated by an analysis of Shewanella oneidensis on crushed hematite. The results of this study provide evidence for the potential of static SIMS to rapidly detect bacterial species based on ion fragments originating from cell membrane lipids directly from sample surfaces.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gali, Emmanuel; Eidenbenz, Stephan; Mniszewski, Sue
The United States' Department of Homeland Security aims to model, simulate, and analyze critical infrastructure and their interdependencies across multiple sectors such as electric power, telecommunications, water distribution, transportation, etc. We introduce ActivitySim, an activity simulator for a population of millions of individual agents each characterized by a set of demographic attributes that is based on US census data. ActivitySim generates daily schedules for each agent that consists of a sequence of activities, such as sleeping, shopping, working etc., each being scheduled at a geographic location, such as businesses or private residences that is appropriate for the activity type andmore » for the personal situation of the agent. ActivitySim has been developed as part of a larger effort to understand the interdependencies among national infrastructure networks and their demand profiles that emerge from the different activities of individuals in baseline scenarios as well as emergency scenarios, such as hurricane evacuations. We present the scalable software engineering principles underlying ActivitySim, the socia-technical modeling paradigms that drive the activity generation, and proof-of-principle results for a scenario in the Twin Cities, MN area of 2.6 M agents.« less
DMD-based LED-illumination super-resolution and optical sectioning microscopy.
Dan, Dan; Lei, Ming; Yao, Baoli; Wang, Wen; Winterhalder, Martin; Zumbusch, Andreas; Qi, Yujiao; Xia, Liang; Yan, Shaohui; Yang, Yanlong; Gao, Peng; Ye, Tong; Zhao, Wei
2013-01-01
Super-resolution three-dimensional (3D) optical microscopy has incomparable advantages over other high-resolution microscopic technologies, such as electron microscopy and atomic force microscopy, in the study of biological molecules, pathways and events in live cells and tissues. We present a novel approach of structured illumination microscopy (SIM) by using a digital micromirror device (DMD) for fringe projection and a low-coherence LED light for illumination. The lateral resolution of 90 nm and the optical sectioning depth of 120 μm were achieved. The maximum acquisition speed for 3D imaging in the optical sectioning mode was 1.6×10(7) pixels/second, which was mainly limited by the sensitivity and speed of the CCD camera. In contrast to other SIM techniques, the DMD-based LED-illumination SIM is cost-effective, ease of multi-wavelength switchable and speckle-noise-free. The 2D super-resolution and 3D optical sectioning modalities can be easily switched and applied to either fluorescent or non-fluorescent specimens.
DMD-based LED-illumination Super-resolution and optical sectioning microscopy
Dan, Dan; Lei, Ming; Yao, Baoli; Wang, Wen; Winterhalder, Martin; Zumbusch, Andreas; Qi, Yujiao; Xia, Liang; Yan, Shaohui; Yang, Yanlong; Gao, Peng; Ye, Tong; Zhao, Wei
2013-01-01
Super-resolution three-dimensional (3D) optical microscopy has incomparable advantages over other high-resolution microscopic technologies, such as electron microscopy and atomic force microscopy, in the study of biological molecules, pathways and events in live cells and tissues. We present a novel approach of structured illumination microscopy (SIM) by using a digital micromirror device (DMD) for fringe projection and a low-coherence LED light for illumination. The lateral resolution of 90 nm and the optical sectioning depth of 120 μm were achieved. The maximum acquisition speed for 3D imaging in the optical sectioning mode was 1.6×107 pixels/second, which was mainly limited by the sensitivity and speed of the CCD camera. In contrast to other SIM techniques, the DMD-based LED-illumination SIM is cost-effective, ease of multi-wavelength switchable and speckle-noise-free. The 2D super-resolution and 3D optical sectioning modalities can be easily switched and applied to either fluorescent or non-fluorescent specimens. PMID:23346373
Model for Sucker-Rod Pumping Unit Operating Modes Analysis Based on SimMechanics Library
NASA Astrophysics Data System (ADS)
Zyuzev, A. M.; Bubnov, M. V.
2018-01-01
The article provides basic information about the process of a sucker-rod pumping unit (SRPU) model developing by means of SimMechanics library in the MATLAB Simulink environment. The model is designed for the development of a pump productivity optimal management algorithms, sensorless diagnostics of the plunger pump and pumpjack, acquisition of the dynamometer card and determination of a dynamic fluid level in the well, normalization of the faulty unit operation before troubleshooting is performed by staff as well as equilibrium ratio determining by energy indicators and outputting of manual balancing recommendations to achieve optimal power consumption efficiency. Particular attention is given to the application of various blocks from SimMechanics library to take into account the pumpjack construction principal characteristic and to obtain an adequate model. The article explains in depth the developed tools features for collecting and analysis of simulated mechanism data. The conclusions were drawn about practical implementation possibility of the SRPU modelling results and areas for further development of investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Zihua; Nachimuthu, Ponnusamy; Lea, Alan S.
2009-10-15
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling of sucrose thin films were investigated using 10 keV C60+, 20 keV C602+, 30 keV C603+, 250 eV, 500 eV and 1000 eV Cs+ and O2+ as sputtering ions. With C60n+ ions, the molecular ion signal initially decreases, and reaches a steady-state that is about 38-51% of its original intensity, depending on the energy of the C60n+ ions. On the contrary, with Cs+ and O2+ sputtering, molecular ion signals decrease quickly to the noise level, even using low energy (250 eV) sputtering ions. In addition, the sucrose/Si interface by C60+ sputtering ismore » much narrower than that of Cs+ and O2+ sputtering. To understand the mechanisms of sputtering-induced damage by these ions, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) were used to characterize the bottoms of these sputter craters. XPS data show very little chemical change in the C60+ sputter crater, while considerable amorphous carbon was found in the O2+ and Cs+ sputter craters, indicating extensive decomposition of the sucrose molecules. AFM images show a very flat bottom in the C60+ sputter crater, while the Cs+ and O2+ sputter crater bottoms are significantly rougher than that of the C60+ sputter crater. Based on above data, we developed a simple model to explain different damage mechanisms during sputtering process.« less
Short-term effects of intravitreal bevacizumab on cornea and anterior chamber.
Güler, Mete; Capkın, Musa; Simşek, Ali; Bilak, Semsettin; Bilgin, Burak; Hakim Reyhan, Ali; Fırat, Müge
2014-10-01
To determine the short-term effects of single-dose intravitreal bevacizumab injection on central corneal thickness (CCT), simulated keratometry (Sim K), anterior chamber depth (ACD), iridocorneal angle (ICA) and intraocular pressure (IOP) measurements. Prospective, nonrandomized, interventional clinical trial. Forty-three eyes of 43 patients aged between 41 and 78 years (average 62 ± 13 years) received an intravitreal injection of 2.5 mg/0.1 mL bevacizumab. Patients who had not undergone additional intravitreal anti-vascular endothelial growth factor therapy within 6 months were included in the study. CCT, Sim K, ACD and ICA measurements were obtained with Sirius Topographer. IOP measurements were taken after topographic measurements with Goldmann applanation tonometer. The CCT, ACD, ICA and IOP measurements were taken before and after 3rd, 15th days and 1st month of intravitreal bevacizumab injection. Pre- and postinjection of 3rd, 15th days and 1st month CCT (p = 0.999), Sim K (p = 0.746), ACD (p = 0.996), ICA (p = 0.632) and IOP (p = 0.707) measurements were not statistically different. Mean CCT (p = 1.000), Sim K (0.972), ACD (p = 0.998), ICA (0.667) and IOP (0.951) values were similar before and after 3rd day of bevacizumab injection. Mean CCT (p = 0.999), Sim K (p = 0.994), ACD (p = 1.000), ICA (p = 0.999) and IOP (p = 1.000) measurements were also similar before and after 15th day of injection. Preinjection and 1st month of postinjection CCT (p = 0.999), Sim K (p = 0.932), ACD (p = 0.998), ICA (p = 1.000) and IOP (p = 0.741) measurements did not change significantly. Single-dose intravitreal bevacizumab injection does not affect CCT, Sim K, ACD, ICA and IOP in short-term period.
Cheng, Christina N; Wingert, Rebecca A
2015-03-01
The mechanisms that establish nephron segments are poorly understood. The zebrafish embryonic kidney, or pronephros, is a simplified yet conserved genetic model to study this renal development process because its nephrons contain segments akin to other vertebrates, including the proximal convoluted and straight tubules (PCT, PST). The zebrafish pronephros is also associated with the corpuscles of Stannius (CS), endocrine glands that regulate calcium and phosphate homeostasis, but whose ontogeny from renal progenitors is largely mysterious. Initial patterning of zebrafish renal progenitors in the intermediate mesoderm (IM) involves the formation of rostral and caudal domains, the former being reliant on retinoic acid (RA) signaling, and the latter being repressed by elevated RA levels. Here, using expression profiling to gain new insights into nephrogenesis, we discovered that the gene single minded family bHLH transcription factor 1a (sim1a) is dynamically expressed in the renal progenitors-first marking the caudal domain, then becoming restricted to the proximal segments, and finally exhibiting specific CS expression. In loss of function studies, sim1a knockdown expanded the PCT and abrogated both the PST and CS populations. Conversely, overexpression of sim1a modestly expanded the PST and CS, while it reduced the PCT. These results show that sim1a activity is necessary and partially sufficient to induce PST and CS fates, and suggest that sim1a may inhibit PCT fate and/or negotiate the PCT/PST boundary. Interestingly, the sim1a expression domain in renal progenitors is responsive to altered levels of RA, suggesting that RA regulates sim1a, directly or indirectly, during nephrogenesis. sim1a deficient embryos treated with exogenous RA formed nephrons that were predominantly composed of PCT segments, but lacked the enlarged PST observed in RA treated wild-types, indicating that RA is not sufficient to rescue the PST in the absence of sim1a expression. Alternately, when sim1a knockdowns were exposed to the RA inhibitor diethylaminobenzaldehyde (DEAB), the CS was abrogated rather than expanded as seen in DEAB treated wild-types, revealing that CS formation in the absence of sim1a cannot be rescued by RA biosynthesis abrogation. Taken together, these data reveal previously unappreciated roles for sim1a in zebrafish pronephric proximal tubule and CS patterning, and are consistent with the model that sim1a acts downstream of RA to mitigate the formation of these lineages. These findings provide new insights into the genetic pathways that direct nephron development, and may have implications for understanding renal birth defects and kidney reprogramming. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Jeon, Seol; Hong, Eunpyo; Kwon, Se-Hun; Lee, Heesoo
2018-06-01
The wear resistance of Ti1-xMexN (Me = Zr, Al, Cr) coatings by the laser carburization process was investigated in terms of local atomic structural changes. The repeated pulsed laser ablation was performed to the Ti1-xMexN coating surfaces after Graphite paste was covered. The friction coefficients of the coating specimens were decreased from ∼0.7 to 0.2, and the formation of cracks and debris was suppressed by implementing the laser ablation process. ToF-SIMS depth profiles showed that the laser carburization helps Carbon penetrate into the coating layer as deep as ∼20 nm below its surface. XPS and XAFS analyses revealed that the improvement of the wear resistance of the coatings was achieved not by formation of TiC or ZrC lattices on the coatings surfaces but by Carbon interstitials to the Ti1-xMexN lattices.
Mesoscopic Perovskite Light-Emitting Diodes.
Palma, Alessandro Lorenzo; Cinà, Lucio; Busby, Yan; Marsella, Andrea; Agresti, Antonio; Pescetelli, Sara; Pireaux, Jean-Jacques; Di Carlo, Aldo
2016-10-03
Solution-processed hybrid bromide perovskite light-emitting-diodes (PLEDs) represent an attractive alternative technology that would allow overcoming the well-known severe efficiency drop in the green spectrum related to conventional LEDs technologies. In this work, we report on the development and characterization of PLEDs fabricated using, for the first time, a mesostructured layout. Stability of PLEDs is a critical issue; remarkably, mesostructured PLEDs devices tested in ambient conditions and without encapsulation showed a lifetime well-above what previously reported with a planar heterojunction layout. Moreover, mesostructured PLEDs measured under full operative conditions showed a remarkably narrow emission spectrum, even lower than what is typically obtained by nitride- or phosphide-based green LEDs. A dynamic analysis has shown fast rise and fall times, demonstrating the suitability of PLEDs for display applications. Combined electrical and advanced structural analyses (Raman, XPS depth profiling, and ToF-SIMS 3D analysis) have been performed to elucidate the degradation mechanism, the results of which are mainly related to the degradation of the hole-transporting material (HTM) and to the perovskite-HTM interface.
Surface and grain boundary interdiffusion in nanometer-scale LSMO/BFO bilayer
NASA Astrophysics Data System (ADS)
Kumar, Virendra; Gaur, Anurag; Choudhary, R. J.; Gupta, Mukul
2016-05-01
Epitaxial 150 nm thick LSMO/BFO bilayer is deposited on STO (100) substrate by pulsed laser deposition, to study magnetoelectric effect. Unexpected low value of room temperature magnetization in bilayer indicates towards the possibility of interdiffusion. Further, sharp fall in the value of TC (53 K) also added our anxiety towards possible interdiffusion in BFO/LSMO system. Low-angle x-ray diffraction technique is used to investigate interdiffusion phenomena, and the temperature-dependent interdiffusivity is obtained by accurately monitoring the decay of the first-order modulation peak as a function of annealing time. It has been found that the diffusivity at different temperatures follows Arrhenius-type behavior. X-ray reflection (XRR) pattern obtained for the bilayer could not be fitted in the Parratt's formalism, which confirms the interdiffusion in it. Depth profiles of 209Bi, 56Fe ions measured by secondary ion mass spectroscope (SIMS) further substantiate the diffusion of these ions from upper BFO layer into lower LSMO layer.
NASA Astrophysics Data System (ADS)
Oltmans, S. J.; Karion, A.; Schnell, R. C.; Pétron, G.; Sweeney, C.; Wolter, S.; Neff, D.; Montzka, S. A.; Miller, B. R.; Helmig, D.; Johnson, B. J.; Hueber, J.
2014-08-01
During the winter of 2012-2013 atmospheric surface ozone mole fractions exceeded the US 8 h standard of 75 ppb on 39 days in the Uinta Basin of Utah. As part of the Uinta Basin Winter Ozone Study (UBWOS) aircraft flights were conducted throughout the basin with continuous measurements of ozone (O3), methane (CH4), carbon dioxide (CO2), carbon monoxide (CO), nitrogen dioxide (NO2), and discrete whole air flask samples for determination of ∼50 trace gases including a number of non-methane hydrocarbons (NMHCs). During the course of seven flights conducted between 31 January and 7 February 2013, coinciding with strong, multi-day temperature inversions, O3 levels gradually built up in the shallow boundary layer from ∼45 ppb to ∼140 ppb. Near-surface CH4 mole fractions increased during the episode from near background levels of ∼2 ppm to over 10 ppm. Based on elevated levels of CH4 across the basin and high correlations of CH4 with NMHCs from the discrete air samples, O3 precursor NMHCs were also inferred to be elevated throughout the basin. Discrete plumes of high NO2 were observed in the gas production region of the basin suggesting that gas processing plants and compressor facilities were important point sources of reactive nitrogen oxides (NOx). Vertical profiles obtained during the flights showed that the high O3 mole fractions (as well as other elevated constituents) were confined to a shallow layer from near the ground to 300-400 m above ground level (m a.g.l.) capped by a strong temperature inversion. The highest mole fractions of the measured constituents during the study period were in an isothermal cold layer that varied from ∼300 m depth on 4 February to ∼150 m on 5 February. A gradient layer with declining mole fractions with altitude extended above the isothermal layer to ∼1900 m a.s.l. (300-400 m a.g.l.) indicative of some mixing of air out of the boundary layer. O3 mole fractions continued to increase within the basin as the high O3 episode developed over the course of a week. CH4 mole fractions, on the other hand, leveled off after several days. On several flights, the aircraft sampled the plume of a coal-fired power plant (located east of the main gas field) flowing above the inversion layer. These measurements ruled out the effluents of the power plant as a significant source of NOx for O3 production beneath the temperature inversion in the basin. The presence of elevated O3 precursors within the basin and the rapid daytime production of O3 in the atmosphere beneath the temperature inversion both indicated that O3 was being produced from precursors emitted within the basin beneath the temperature inversion. Although observations show that horizontal winds in the surface layer were relatively light during the high ozone event, they were sufficient to disperse precursors up to 80 km from primary sources in the main gas field in the southeast quadrant to the balance of the Uinta Basin.
Water in Earth's mantle: Hydrogen analysis of mantle olivine, pyroxenes and garnet using the SIMS
NASA Technical Reports Server (NTRS)
Kurosawa, Masanori; Yurimoto, Hisayoshi; Sueno, Shigeho
1993-01-01
Hydrogen (or water) in the Earth's interior plays a key role in the evolution and dynamics of the planet. However, the abundance and the existence form of the hydrogen have scarcely been clear in practice. Hydrogen in the mantle was incorporated in the interior during the formation of the Earth. The incorporated hydrogen was hardly possible to concentrate locally inside the Earth considering its high mobility and high reactivity. The hydrogen, preferably, could be distributed homogeneously over the mantle and the core by the subsequent physical and chemical processes. Therefore, hydrogen in the mantle could be present in the form of trace hydrogen in nominally anhydrous mantle minerals. The hydrogen and the other trace elements in mantle olivines, orthopyroxenes, clinopyroxenes, and garnets were determined using secondary ion mass spectrometry (SIMS) for elucidating (1) the exact hydrogen contents, (2) the correlation between the hydrogen and the other trace elements, (3) the dependence of the hydrogen contents on the depth, and (4) the dependence of the whole rock water contents on the depth.
NASA Astrophysics Data System (ADS)
Chen, Youhua; Cao, Ruizhi; Liu, Wenjie; Zhu, Dazhao; Zhang, Zhiming; Kuang, Cuifang; Liu, Xu
2018-04-01
We present an alternative approach to realize structured illumination microscopy (SIM), which is capable for live cell imaging. The prototype utilizes two sets of scanning galvo mirrors, a polarization converter and a piezo-platform to generate a fast shifted, s-polarization interfered and periodic variable illumination patterns. By changing the angle of the scanning galvanometer, we can change the position of the spots at the pupil plane of the objective lens arbitrarily, making it easy to switch between widefield and total internal reflection fluorescent-SIM mode and adapting the penetration depth in the sample. Also, a twofold resolution improvement is achieved in our experiments. The prototype offers more flexibility of pattern period and illumination orientation changing than previous systems.
Ravella, Uday K; Liu, Jingjing; Corbel, Gwenaël; Skinner, Stephen J; Lacorre, Philippe
2016-08-23
Among standard high-temperature cathode materials for solid oxide fuel cells, La0.8 Sr0.2 MnO3-δ (LSM) displays the least reactivity with the oxide-ion conductor La2 Mo2 O9 (LMO), yet a reaction is observed at high processing temperatures, identified by using XRD and focused ion beam secondary-ion mass spectrometry (FIB-SIMS) after annealing at 1050 and 1150 °C. Additionally, Sr and Mn solutions were deposited and annealed on LMO pellets, as well as a Mo solution on a LSM pellet. From these studies several reaction products were identified by using XRD and located by using FIB-SIMS on the surface of pelletised samples. We used depth profiling to show that the reactivity extended up to ∼10 μm from the surface region. If Sr was present, a SrMoO4 -type scheelite phase was always observed as a reaction product, and if Mn was present, LaMnO3+δ single crystals were observed on the surface of the LMO pellets. Additional phases such as La2 MoO6 and La6 MoO12 were also detected depending on the configuration and annealing temperature. Reaction mechanisms and detailed reaction formulae are proposed to explain these observations. The strongest driving force for cationic diffusion appears to originate from Mo(6+) and Mn(3+) cations, rather than from Sr(2+) . © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A major change in North Atlantic deep water circulation 1.6 million years ago
NASA Astrophysics Data System (ADS)
Khélifi, N.; Frank, M.
2014-07-01
The global ocean-climate system has been highly sensitive to the formation and advection of deep overflow water from the Nordic Seas as integral part of the Atlantic Meridional Overturning Circulation (AMOC) but its evolution over the Pliocene-Pleistocene global cooling is not fully understood. In particular, changes in the sources and mixing of prevailing deep waters that were involved in driving overturning throughout the Pliocene-Pleistocene climate transitions are not well constrained. Here we investigate the evolution of a substantial deep southward return overflow of the AMOC over the last 4 million years. We present new records of the bottom-water radiogenic neodymium isotope (ϵNd) variability obtained from three sediment cores (DSDP site 610 and ODP sites 980/981 and 900) at water depths between 2170 and 5050 m in the northeast Atlantic. We find that prior to the onset of major Northern Hemisphere glaciation (NHG) ∼3 million years ago (Ma), ϵNd values primarily oscillated between -9 and -11 at all sites, consistent with enhanced vertical mixing and weak stratification of the water masses during the warmer-than-today Pliocene period. From 2.7 Ma to ∼2.0 Ma, the ϵNd signatures of the water masses gradually became more distinct, which documents a significant advection of Nordic Seas overflow deep water coincident with the intensification of NHG. Most markedly, however, at ∼1.6 Ma the interglacial ϵNd signatures at sites 610 (2420 m water depth (w.d.)) and 980/981 (2170 m w.d.) synchronously and permanently shifted by 2 to 3 ϵNd units to less radiogenic values, respectively. Since then the difference between glacial and interglacial ϵNd values has been similar to the Late Quaternary at each site. A decrease of ∼2ϵNd units at 1.6 Ma was also recorded for the deepest water masses by site 900 (∼5050 m w.d.), which thereafter, however, evolved to more radiogenic values again until the present. This major ϵNd change across the 1.6 Ma transition reflects a significant reorganization of the overturning circulation in the northeast Atlantic paving the way for the more stratified water column with distinct water masses prevailing thereafter.
Health information systems and pesticide poisoning at Pernambuco.
de Albuquerque, Pedro Costa Cavalcanti; Gurgel, Idê Gomes Dantas; Gurgel, Aline do Monte; Augusto, Lia Giraldo da Silva; de Siqueira, Marília Teixeira
2015-01-01
Understanding the epidemiologic profile of a particular disease is key to undertake health actions. To that end, information systems that present quality data help in the decision-making process and demonstrate the impact of the problems. To analyze the contribution of health information systems for the characterization of pesticide poisoning through SINAN, CEATOX and SIM in the State of Pernambuco. In this study, the completeness and consistency of the data were assessed, as well as the epidemiological profile of pesticide poisoning in Pernambuco in the period from 2008 to 2012, based on the following Health Information Systems: Center for Toxicological Assistance of Pernambuco (CEATOX), Notifiable Diseases Information System (SINAN) and Mortality Information System (SIM). The data revealed incompleteness and inconsistencies in information. Regarding the profile, females are more affected in the morbidity profile, and men have a higher mortality rate. Poisoning was more frequent in young adults with low educational level. With regard to the circumstances, most of the cases were suicide attempts, unique acute cases and not related to work. Despite suggesting underreporting, the data showed that persons engaged in agriculture are most commonly affected. The strengthening of these systems is necessary for the generation of consistent information that support health policies for the population groups involved.
Effect of motion inputs on the wear prediction of artificial hip joints
Liu, Feng; Fisher, John; Jin, Zhongmin
2013-01-01
Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear modelling has been improved recently for the conventional UHMWPE used in total hip joint replacements. A new polyethylene wear law is an explicit function of the contact area of the bearing and the sliding distance, and the effect of multidirectional motion on wear has been quantified by a factor, cross-shear ratio. In this study, the full simulated walking cycle condition based on a walking measurement and two simplified motions, including the ISO standard motion and a simplified ProSim hip simulator motion, were considered as the inputs for wear modelling based on the improved wear model. Both the full simulation and simplified motions generated the comparable multidirectional motion required to reproduce the physiological wear of the bearing in vivo. The predicted volumetric wear of the ProSim simulator motion and the ISO motion conditions for the walking cycle were 13% and 4% lower, respectively, than that of the measured walking condition. The maximum linear wear depths were almost the same, and the areas of the wear depth distribution were 13% and 7% lower for the ProSim simulator and the ISO condition, respectively, compared with that of the measured walking cycle motion condition. PMID:25540472
A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
Young, Laurence J.; Ströhl, Florian; Kaminski, Clemens F.
2016-01-01
Optical super-resolution imaging with structured illumination microscopy (SIM) is a key technology for the visualization of processes at the molecular level in the chemical and biomedical sciences. Although commercial SIM systems are available, systems that are custom designed in the laboratory can outperform commercial systems, the latter typically designed for ease of use and general purpose applications, both in terms of imaging fidelity and speed. This article presents an in-depth guide to building a SIM system that uses total internal reflection (TIR) illumination and is capable of imaging at up to 10 Hz in three colors at a resolution reaching 100 nm. Due to the combination of SIM and TIRF, the system provides better image contrast than rival technologies. To achieve these specifications, several optical elements are used to enable automated control over the polarization state and spatial structure of the illumination light for all available excitation wavelengths. Full details on hardware implementation and control are given to achieve synchronization between excitation light pattern generation, wavelength, polarization state, and camera control with an emphasis on achieving maximum acquisition frame rate. A step-by-step protocol for system alignment and calibration is presented and the achievable resolution improvement is validated on ideal test samples. The capability for video-rate super-resolution imaging is demonstrated with living cells. PMID:27285848
NASA Astrophysics Data System (ADS)
Nauer, P. A.; Dam, B.; Liesack, W.; Zeyer, J.; Schroth, M. H.
2012-01-01
The global methane (CH4) cycle is largely driven by methanogenic archaea and methane-oxidizing bacteria (MOB), but little is known about their activity and diversity in pioneer ecosystems. We conducted a field survey in forefields of 13 receding Swiss glaciers on both siliceous and calcareous bedrock to investigate and quantify CH4 turnover based on soil-gas CH4 concentration profiles, and to characterize MOB communities using pmoA sequencing and T-RFLP. Methane turnover was fundamentally different in the two bedrock categories. Of the 36 CH4 concentration profiles from siliceous locations, 11 showed atmospheric CH4 consumption at concentrations of ∼1-2 μl l-1 with soil-atmosphere CH4 fluxes of -0.14 to -1.1 mg m-2 d-1. Another 11 profiles showed no apparent activity, while the remaining 14 exhibited slightly increased CH4 concentrations of ∼2-10 μl l-1, most likely due to microsite methanogenesis. In contrast, all profiles from calcareous sites suggested a substantial, yet unknown CH4 source below our sampling zone, with soil-gas CH4 concentrations reaching up to 1400 μl l-1. Remarkably, most soils oxidized ∼90% of the deep-soil CH4, resulting in soil-atmosphere fluxes of 0.12 to 31 mg m-2 d-1. MOB showed limited diversity in both siliceous and calcareous forefields: all identified pmoA sequences formed only 5 OTUs and, with one exception, could be assigned to either Methylocystis or the as-yet-uncultivated Upland Soil Cluster γ (USCγ). The latter dominated T-RFLP patterns of all siliceous and most calcareous samples, while Methylocystis dominated in 4 calcareous samples. As Type I MOB are widespread in cold climate habitats with elevated CH4 concentrations, USCγ might be the corresponding Type I MOBs in habitats exposed to near-atmospheric CH4 concentrations.
Bluestein, Blake M; Morrish, Fionnuala; Graham, Daniel J; Guenthoer, Jamie; Hockenbery, David; Porter, Peggy L; Gamble, Lara J
2016-03-21
Imaging time-of-flight secondary ion mass spectrometry (ToF-SIMS) and principal component analysis (PCA) were used to investigate two sets of pre- and post-chemotherapy human breast tumor tissue sections to characterize lipids associated with tumor metabolic flexibility and response to treatment. The micron spatial resolution imaging capability of ToF-SIMS provides a powerful approach to attain spatially-resolved molecular and cellular data from cancerous tissues not available with conventional imaging techniques. Three ca. 1 mm(2) areas per tissue section were analyzed by stitching together 200 μm × 200 μm raster area scans. A method to isolate and analyze specific tissue regions of interest by utilizing PCA of ToF-SIMS images is presented, which allowed separation of cellularized areas from stromal areas. These PCA-generated regions of interest were then used as masks to reconstruct representative spectra from specifically stromal or cellular regions. The advantage of this unsupervised selection method is a reduction in scatter in the spectral PCA results when compared to analyzing all tissue areas or analyzing areas highlighted by a pathologist. Utilizing this method, stromal and cellular regions of breast tissue biopsies taken pre- versus post-chemotherapy demonstrate chemical separation using negatively-charged ion species. In this sample set, the cellular regions were predominantly all cancer cells. Fatty acids (i.e. palmitic, oleic, and stearic), monoacylglycerols, diacylglycerols and vitamin E profiles were distinctively different between the pre- and post-therapy tissues. These results validate a new unsupervised method to isolate and interpret biochemically distinct regions in cancer tissues using imaging ToF-SIMS data. In addition, the method developed here can provide a framework to compare a variety of tissue samples using imaging ToF-SIMS, especially where there is section-to-section variability that makes it difficult to use a serial hematoxylin and eosin (H&E) stained section to direct the SIMS analysis.
A possible mechanism to detect super-earth formation in protoplanetary disks
NASA Astrophysics Data System (ADS)
Dong, Ruobing; Chiang, Eugene; Li, Hui; Li, Shengtai
2017-06-01
Using combined gas+dust global hydrodynamics and radiative transfer simulations, we calculate the distribution of gas and sub-mm-sized dust in protoplanetary disks with a super-Earth at tens of AU, and examine observational signatures of such systems in resolved observations. We confirm previous results that in a typical disk with a low viscosity ($\\alpha\\lesssim10^{-4}$), a super-Earth is able to open two gaps at $\\sim$scale-height away around its orbit in $\\sim$mm-sized dust (St$\\sim$0.01), due to differential dust drift in a perturbed gas background. Additional rings and gaps may also be produced under certain conditions. These features, particularly a signature ``double-gap'' feature, can be detected in a Taurus target by ALMA in dust continuum under an angular resolution of $\\sim0\\arcsec.025$ with two hours of integration. The features are robust --- it can survive in a variety of background disk profiles, withstand modest planetary radial migration ($|r/\\dot{r}|\\sim$ a few Myr), and last for thousands of orbits. Multiple ring/gap systems observed by ALMA were typically modeled using multiple (Saturn-to-Jupiter sized) planets. Here, we argue that a single super-Earth in a low viscosity disk could produce multiple rings and gaps as well. By examining the prevalence of such features in nearby disks, upcoming high angular resolution ALMA surveys may infer how common super-Earth formation events are at tens of au.
Sjögren, Erik; Westergren, Jan; Grant, Iain; Hanisch, Gunilla; Lindfors, Lennart; Lennernäs, Hans; Abrahamsson, Bertil; Tannergren, Christer
2013-07-16
Oral drug delivery is the predominant administration route for a major part of the pharmaceutical products used worldwide. Further understanding and improvement of gastrointestinal drug absorption predictions is currently a highly prioritized area of research within the pharmaceutical industry. The fraction absorbed (fabs) of an oral dose after administration of a solid dosage form is a key parameter in the estimation of the in vivo performance of an orally administrated drug formulation. This study discloses an evaluation of the predictive performance of the mechanistic physiologically based absorption model GI-Sim. GI-Sim deploys a compartmental gastrointestinal absorption and transit model as well as algorithms describing permeability, dissolution rate, salt effects, partitioning into micelles, particle and micelle drifting in the aqueous boundary layer, particle growth and amorphous or crystalline precipitation. Twelve APIs with reported or expected absorption limitations in humans, due to permeability, dissolution and/or solubility, were investigated. Predictions of the intestinal absorption for different doses and formulations were performed based on physicochemical and biopharmaceutical properties, such as solubility in buffer and simulated intestinal fluid, molecular weight, pK(a), diffusivity and molecule density, measured or estimated human effective permeability and particle size distribution. The performance of GI-Sim was evaluated by comparing predicted plasma concentration-time profiles along with oral pharmacokinetic parameters originating from clinical studies in healthy individuals. The capability of GI-Sim to correctly predict impact of dose and particle size as well as the in vivo performance of nanoformulations was also investigated. The overall predictive performance of GI-Sim was good as >95% of the predicted pharmacokinetic parameters (C(max) and AUC) were within a 2-fold deviation from the clinical observations and the predicted plasma AUC was within one standard deviation of the observed mean plasma AUC in 74% of the simulations. GI-Sim was also able to correctly capture the trends in dose- and particle size dependent absorption for the study drugs with solubility and dissolution limited absorption, respectively. In addition, GI-Sim was also shown to be able to predict the increase in absorption and plasma exposure achieved with nanoformulations. Based on the results, the performance of GI-Sim was shown to be suitable for early risk assessment as well as to guide decision making in pharmaceutical formulation development. Copyright © 2013 Elsevier B.V. All rights reserved.
Mon, Marta; Pascual-Álvarez, Alejandro; Grancha, Thais; Cano, Joan; Ferrando-Soria, Jesús; Lloret, Francesc; Gascon, Jorge; Pasán, Jorge; Armentano, Donatella; Pardo, Emilio
2016-01-11
Single-ion magnets (SIMs) are the smallest possible magnetic devices and are a controllable, bottom-up approach to nanoscale magnetism with potential applications in quantum computing and high-density information storage. In this work, we take advantage of the promising, but yet insufficiently explored, solid-state chemistry of metal-organic frameworks (MOFs) to report the single-crystal to single-crystal inclusion of such molecular nanomagnets within the pores of a magnetic MOF. The resulting host-guest supramolecular aggregate is used as a playground in the first in-depth study on the interplay between the internal magnetic field created by the long-range magnetic ordering of the structured MOF and the slow magnetic relaxation of the SIM. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
This manuscript examines the relationship between cholinesterase inhibition and behavioral effects produced by two pesticides, fenamiphos and profenophos. Both pesticides greatly inhibit blood cholinesterase but the brain is relatively spared up to lethal doses. Despite the sim...
NASA Technical Reports Server (NTRS)
1979-01-01
The findings of the IIT Research Institute (IITRI) market study of the SIMS Prototype System 4, a hot water (DHW) system are documented. The feasibility of prepackaging currently available solar heating components into modular subsystems for site assembly is addressed. A documented design and installation procedure and a performance test report were prepared. The potential markets and applications for this particular system in the nonfederal market are profiled by assessing the needs and requirements of potential users and specifiers, by characterizing the nature of the market and the competitive environment, by identifying the barriers to commercial acceptance, and by estimating the size of the potential market.
The smallest Gliders in the Ocean- Temperature Recordings from Pteropods using SIMS
NASA Astrophysics Data System (ADS)
Keul, N.; Orland, I. J.; Valley, J. W.; Kozdon, R.; deMenocal, P. B.
2016-02-01
During the last few decades, the development, refinement and application of geochemical methods have lead to the establishment of new proxies to estimate global change. The oxygen isotope composition of carbonate shells formed by marine organisms is a widely used proxy for past ocean temperatures. Secondary ion mass spectrometry (SIMS) is a high spatial-resolution in situ technique, allowing oxygen isotope measurements on very small samples (down to 3 μm spot size). Pteropods are pelagic mollusks, producing shells made out of aragonite, which is more soluble than calcite in seawater, making them one of the first responders to climate change. They calcify closely at the aragonite- seawater equilibrium and are therefor ideal candidates to reconstruct temperatures based on their d18O. The oxygen isotopic composition of pteropod shells from sediment traps, net tows and a culture study from the Fram Strait will be presented. Specimens travelled in the Westspitsbergen Current prior to sinking into the sediment. During this transport specimens continue to grow, sequentially adding aragonite to the shell. We show that when using traditional (whole shell) δ18O measurements, the isotopic signatures of whole shells reflect the latitudinal gradient. Combining this with SIMS-derived δ18O measurements on individual shell parts, however, reveals that this is only half the story: Comparing δ18O of earlier (produced further South) and later shell parts (produced further North) shows that pteropods calcify in sequentially shallower water depths, overriding the latitudinal South to North temperature gradient. Combining traditional and novel δ18O measurements can potentially not only allow the reconstruction of temperature/ global warming, but also to assess ecological key parameters, such as habitat depth, at the same time.
Earth's copper resources estimated from tectonic diffusion of porphyry copper deposits
NASA Astrophysics Data System (ADS)
Kesler, Stephen E.; Wilkinson, Bruce H.
2008-03-01
Improved estimates of global mineral endowments are relevantto issues ranging from strategic planning to global geochemicalcycling. We have used a time-space model for the tectonic migrationof porphyry copper deposits vertically through the crust tocalculate Earth's endowment of copper in mineral deposits. Themodel relies only on knowledge of numbers and ages of porphyrycopper deposits, Earth's most widespread and important sourceof copper, in order to estimate numbers of eroded and preserveddeposits in the crust. Model results indicate that
125,895 porphyrycopper deposits were formed during Phanerozoic time, that only
47,789 of these remain at various crustal depths, and that thesecontain
1.7 x 1011 tonnes (t) of copper. Assuming that othertypes of copper deposits behave similarly in the crust and haveabundances proportional to their current global production yieldsan estimate of 3 x 1011 t for total global copper resourcesat all levels in Earth's crust. Thus,
0.25% of the copper inthe crust has been concentrated into deposits through Phanerozoictime, and about two-thirds of this has been recycled by upliftand erosion. The amount of copper in deposits above 3.3 km,a likely limit of future mining, could supply current worldmine production for 5500 yr, thus quantifying the highly unusualand nonrenewable nature of mineral deposits.
Characterizing Ocean Turbulence from Argo, Acoustic Doppler, and Simulation Data
NASA Astrophysics Data System (ADS)
McCaffrey, Katherine
Turbulence is inherently chaotic and unsteady, so observing it and modeling it are no easy tasks. The ocean's sheer size makes it even more difficult to observe, and its unpredictable and ever-changing forcings introduce additional complexities. Turbulence in the oceans ranges from basin scale to the scale of the molecular viscosity. The method of energy transfer between scales is, however, an area of active research, so observations of the ocean at all scales are crucial to understanding the basic dynamics of its motions. In this collection of work, I use a variety of datasets to characterize a wide range of scales of turbulence, including observations from multiple instruments and from models with different governing equations. I analyzed the largest scales of the turbulent range using the global salinity data of the Argo profiling float network. Taking advantage of the scattered and discontinuous nature of this dataset, the second-order structure function was calculated down to 2000m depth, and shown to be useful for predicting spectral slopes. Results showed structure function slopes of 2/3 at small scales, and 0 at large scales, which corresponds with spectral slopes of -5/3 at small scales, and -1 at large scales. Using acoustic Doppler velocity measurements, I characterized the meter- to kilometer-scale turbulence at a potential tidal energy site in the Puget Sound, WA. Acoustic Doppler current profiler (ADCP) and acoustic Doppler velocimeter (ADV) observations provided the data for an analysis that includes coherence, anisotropy, and intermittency. In order to more simply describe these features, a parameterization was done with four turbulence metrics, and the anisotropy magnitude, introduced here, was shown to most closely capture the coherent events. Then, using both the NREL TurbSim stochastic turbulence generator and the NCAR large-eddy simulation (LES) model, I calculated turbulence statistics to validate the accuracy of these methods in reproducing the tidal channel. TurbSim models statistics at the height of a turbine hub (5m) well, but do not model coherent events, while the LES does create these events, but not realistically in this configuration, based on comparisons with observations. Each of the datasets have disadvantages when it comes to observing turbulence. The Argo network is sparse in space, and few measurements are taken simultaneously in time. Therefore spatial and temporal averaging is needed, which requires the turbulence to be homogeneous and stationary if it is to be generalized. Though the acoustic Doppler current profiler provides a vertical profile of velocities, the fluctuations are dominated by instrument noise and beam spread, preventing it from being used for most turbulence metrics. ADV measurements have much less noise, and no beam spread, but the observations are made at one point in space, limiting us to temporal statistics or an assumption of "frozen turbulence" to infer spatial scales. As for the models, TurbSim does not have any real-world forcing, and uses parameterized spectra, and coherence functions and randomizes phase information, while LES models must make assumptions about sub-grid scales, which may be inaccurate. Additionally, all models are set up with idealizations of the forcing and domain, which may make the results unlike observations in a particular location and time. Despite these difficulties in observing and characterizing turbulence, I present several quantities that use the imperfect, yet still valuable observations, to attain a better description of the turbulence in the oceans.
Aydin, Halit; Korte, Carsten; Janek, Jürgen
2013-06-01
The oxygen tracer diffusion coefficient describing transport along nano-/microscaled YSZ/Sc 2 O 3 multilayers as a function of the thick-ness of the ion-conducting YSZ layers has been measured by isotope exchange depth profiling (IEDP), using secondary ion mass spec-trometry (SIMS). The multilayer samples were prepared by pulsed laser deposition (PLD) on (0001) Al 2 O 3 single crystalline substrates. The values for the oxygen tracer diffusion coefficient were analyzed as a combination of contributions from bulk and interface contributions and compared with results from YSZ/Y 2 O 3 -multilayers with similar microstructure. Using the Nernst-Einstein equation as the relation between diffusivity and electrical conductivity we find very good agreement between conductivity and diffusion data, and we exclude substantial electronic conductivity in the multilayers. The effect of hetero-interface transport can be well explained by a simple interface strain model. As the multilayer samples consist of columnar film crystallites with a defined inter-face structure and texture, we also discuss the influence of this particular microstructure on the interfacial strain.
Characterization of 4H <000-1> Silicon Carbide Films Grown by Solvent-Laser Heated Floating Zone
NASA Technical Reports Server (NTRS)
Woodworth, Andrew, A; Sayir, Ali; Neudeck, Philip, G; Raghothamachar, Balaji; Dudley, Michael
2012-01-01
Commercially available bulk silicon carbide (SiC) has a high number (>2000/sq cm) of screw dislocations (SD) that have been linked to degradation of high-field power device electrical performance properties. Researchers at the NASA Glenn Research Center have proposed a method to mass-produce significantly higher quality bulk SiC. In order for this bulk growth method to become reality, growth of long single crystal SiC fibers must first be achieved. Therefore, a new growth method, Solvent-Laser Heated Floating Zone (Solvent-LHFZ), has been implemented. While some of the initial Solvent-LHFZ results have recently been reported, this paper focuses on further characterization of grown crystals and their growth fronts. To this end, secondary ion mass spectroscopy (SIMS) depth profiles, cross section analysis by focused ion beam (FIB) milling and mechanical polishing, and orientation and structural characterization by x-ray transmission Laue diffraction patterns and x-ray topography were used. Results paint a picture of a chaotic growth front, with Fe incorporation dependant on C concentration.
DIFFUSION OF MAGNESIUM AND MICROSTRUCTURES IN Mg+ IMPLANTED SILICON CARBIDE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Weilin; Edwards, Danny J.; Jung, Hee Joon
2014-08-28
Following our previous reports [ 1- 3], further isochronal annealing (2 hrs.) of the monocrystalline 6H-SiC and polycrystalline CVD 3C-SiC was performed at 1573 and 1673 K in Ar environment. SIMS data indicate that observable Mg diffusion in 6H-SiC starts and a more rapid diffusion in CVD 3C-SiC occurs at 1573 K. The implanted Mg atoms tend to diffuse deeper into the undamaged CVD 3C-SiC. The microstructure with Mg inclusions in the as-implanted SiC has been initially examined using high-resolution STEM. The presence of Mg in the TEM specimen has been confirmed based on EDS mapping. Additional monocrystalline 3C-SiC samplesmore » have been implanted at 673 K to ion fluence 3 times higher than the previous one. RBS/C analysis has been performed before and after thermal annealing at 1573 K for 12 hrs. Isothermal annealing at 1573 K is being carried out and Mg depth profiles being measured. Microstructures in both the as-implanted and annealed samples are also being examined using STEM.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varley, J. B.; Conway, A. M.; Voss, L. F.
Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-xCL xmore » surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-xC1 X. This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.« less
NASA Astrophysics Data System (ADS)
Jong, Chao-An; Gan, Jon-Yiew
2000-02-01
Strontium barium niobium (Sr0.5Ba0.5Nb2O6) (SBN) thin films are prepared on conductive-oxide LNO (LaNiO3) electrodes by the rf magnetron sputtering system. Instead of conventional furnace annealing, SBN thin films are crystallized by rapid thermal annealing (RTA) above 700°C for 5 min. The textured SBN films are crystallized with two orientations: one is the (001) or (310) direction, and the other is the (002) or (620) direction. Films compositions measured by the electron spectroscopy of chemical analysis (ESCA) quantitative analysis method show nearly the same stoichiometric ratio as the target. The depth profiles of SBN films and the target are examined by secondary ion mass spectrometer (SIMS). The concentrations of the films are quite uniform. After being heat treated at 800°C for 5 min by RTA, La and Ni diffuse into the SBN film. The diffusion coefficient of La in SBN films is also calculated.
NASA Astrophysics Data System (ADS)
Chandran, Maneesh; Michaelson, Shaul; Saguy, Cecile; Hoffman, Alon
2016-11-01
In this letter, we report on the proof of a concept of an innovative delta doping technique to fabricate an ensemble of nitrogen vacancy centers at shallow depths in (100) diamond. A nitrogen delta doped layer with a concentration of ˜1.8 × 1020 cm-3 and a thickness of a few nanometers was produced using this method. Nitrogen delta doping was realized by producing a stable nitrogen terminated (N-terminated) diamond surface using the RF nitridation process and subsequently depositing a thin layer of diamond on the N-terminated diamond surface. The concentration of nitrogen on the N-terminated diamond surface and its stability upon exposure to chemical vapor deposition conditions are determined by x-ray photoelectron spectroscopy analysis. The SIMS profile exhibits a positive concentration gradient of 1.9 nm/decade and a negative gradient of 4.2 nm/decade. The proposed method offers a finer control on the thickness of the delta doped layer than the currently used ion implantation and delta doping techniques.
Long-term reproducibility of relative sensitivity factors obtained with CAMECA Wf
NASA Astrophysics Data System (ADS)
Gui, D.; Xing, Z. X.; Huang, Y. H.; Mo, Z. Q.; Hua, Y. N.; Zhao, S. P.; Cha, L. Z.
2008-12-01
As the wafer size continues to increase and the feature size of the integrated circuits (IC) continues to shrink, process control of IC manufacturing becomes ever more important to reduce the cost of failures caused by the drift of processes or equipments. Characterization tools with high precision and reproducibility are required to capture any abnormality of the process. Although Secondary ion mass spectrometry (SIMS) has been widely used in dopant profile control, it was reported that magnetic sector SIMS, compared to quadrupole SIMS, has lower short-term repeatability and long-term reproducibility due to the high extraction field applied between sample and extraction lens. In this paper, we demonstrate that CAMECA Wf can deliver high long-term reproducibility because of its high-level automation and improved design of immersion lens. The relative standard deviation (R.S.D.) of the relative sensitivity factors (RSF) of three typical elements, i.e., boron (B), phosphorous (P) and nitrogen (N), over 3 years are 3.7%, 5.5% and 4.1%, respectively. The high reproducibility results have a practical implication that deviation can be estimated without testing the standards.
Hanson, N N; Wurster, C M; Todd, C D
2010-09-15
The chemical signals in the sequential layers of fish otoliths have the potential to provide fisheries biologists with temporal and spatial details of migration which are difficult to obtain without expensive tracking methods. Signal resolution depends, however, on the extraction technique used. We compared the use of mechanical micromilling and continuous flow isotope ratio mass spectrometry (CF-IRMS) methods with secondary ion mass spectrometry (SIMS) to obtain delta(18)O profiles from otoliths of wild Atlantic salmon (Salmo salar) and used these to corroborate the time of freshwater emigration of the juvenile with macroscopic patterns within the otolith. Both techniques showed the transition occurring at the same visible feature on the otolith, allowing future analyses to easily identify the juvenile (freshwater) versus adult (marine) life-stages. However, SIMS showed a rapid and abrupt transition whereas micromilling provided a less distinct signal. The number of samples that could be obtained per unit area sampled using SIMS was 2 to 3 times greater than that when using micromilling/CF-IRMS although the delta(18)O values and analytical precisions (approximately 0.2 per thousand) of the two methods were comparable. In addition, SIMS delta(18)O results were used to compare otolith aragonite values with predicted values calculated using various isotope fractionation equations. Copyright 2010 John Wiley & Sons, Ltd.
Southern Salish Sea Habitat Map Series data catalog
Cochrane, Guy R.
2015-01-01
This data catalog contains much of the data used to prepare the SIMs in the Southern Salish Sea Habitat Map Series. Other data that were used to prepare the maps were compiled from previously published sources (for example, sediment samples and seismic reflection profiles) and are not included in this data series.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yunin, P. A., E-mail: yunin@ipmras.ru; Drozdov, Yu. N.; Drozdov, M. N.
2013-12-15
In this publication, we report the results of studying a multilayerd nonperiodic SiGe/Si structure by the methods of X-ray diffractometry, grazing-angle X-ray reflectometry, and secondary-ion mass spectrometry (SIMS). Special attention is paid to the processing of the component distribution profile using the SIMS method and to consideration of the most significant experimental distortions introduced by this method. A method for processing the measured composition distribution profile with subsequent consideration of the influence of matrix effects, variation in the etching rate, and remnants of ion sputtering is suggested. The results of such processing are compared with a structure model obtained uponmore » combined analysis of X-ray diffractometry and grazing-angle reflectometry data. Good agreement between the results is established. It is shown that the combined use of independent techniques makes it possible to improve the methods of secondary-ion mass spectrometry and grazing-incidence reflectometry as applied to an analysis of multilayered heteroepitaxial structures (to increase the accuracy and informativity of these methods)« less
The effects of Dark Matter annihilation on cosmic reionization
Kaurov, Alexander A.; Hooper, Dan; Gnedin, Nickolay Y.
2016-12-15
We revisit the possibility of constraining the properties of dark matter (DM) by studying the epoch of cosmic reionization. Previous studies have shown that DM annihilation was unlikely to have provided a large fraction of the photons that ionized the universe, but instead played a subdominant role relative to stars and quasars. The DM, however, begins to efficiently annihilate with the formation of primordial microhalos atmore » $$z\\sim100-200$$, much earlier than the formation of the first stars. Therefore, if DM annihilation ionized the universe at even the percent level over the interval $$z \\sim 20-100$$, it can leave a significant imprint on the global optical depth, $$\\tau$$. Moreover, we show that cosmic microwave background (CMB) polarization data and future 21 cm measurements will enable us to more directly probe the DM contribution to the optical depth. In order to compute the annihilation rate throughout the epoch of reionization, we adopt the latest results from structure formation studies and explore the impact of various free parameters on our results. Here, we show that future measurements could make it possible to place constraints on the dark matter's annihilation cross section that are at a level comparable to those obtained from the observations of dwarf galaxies, cosmic ray measurements, and studies of recombination.« less
Dark Energy Survey Year 1 Results: The Photometric Data Set for Cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drlica-Wagner, A.; Sevilla-Noarbe, I.; Rykoff, E. S.
In this paper, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zero-points, object catalogs, and ancillary data products—e.g., maps of survey depth and observing conditions, star–galaxy classification, and photometric redshift estimates—that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists ofmore » $$\\sim 137$$ million objects detected in co-added images covering $$\\sim 1800\\,{\\deg }^{2}$$ in the DES grizY filters. The 10σ limiting magnitude for galaxies is $g=23.4$, $r=23.2$, $i=22.5$, $z=21.8$, and $Y=20.1$. Photometric calibration of Y1A1 GOLD was performed by combining nightly zero-point solutions with stellar locus regression, and the absolute calibration accuracy is better than 2% over the survey area. Finally, DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲ 1.« less
Dark Energy Survey Year 1 Results: The Photometric Data Set for Cosmology
Drlica-Wagner, A.; Sevilla-Noarbe, I.; Rykoff, E. S.; ...
2018-04-03
In this paper, we describe the creation, content, and validation of the Dark Energy Survey (DES) internal year-one cosmology data set, Y1A1 GOLD, in support of upcoming cosmological analyses. The Y1A1 GOLD data set is assembled from multiple epochs of DES imaging and consists of calibrated photometric zero-points, object catalogs, and ancillary data products—e.g., maps of survey depth and observing conditions, star–galaxy classification, and photometric redshift estimates—that are necessary for accurate cosmological analyses. The Y1A1 GOLD wide-area object catalog consists ofmore » $$\\sim 137$$ million objects detected in co-added images covering $$\\sim 1800\\,{\\deg }^{2}$$ in the DES grizY filters. The 10σ limiting magnitude for galaxies is $g=23.4$, $r=23.2$, $i=22.5$, $z=21.8$, and $Y=20.1$. Photometric calibration of Y1A1 GOLD was performed by combining nightly zero-point solutions with stellar locus regression, and the absolute calibration accuracy is better than 2% over the survey area. Finally, DES Y1A1 GOLD is the largest photometric data set at the achieved depth to date, enabling precise measurements of cosmic acceleration at z ≲ 1.« less
Chemical abrasion-SIMS (CA-SIMS) U-Pb dating of zircon from the late Eocene Caetano caldera, Nevada
Watts, Kathryn E.; Coble, Matthew A.; Vazquez, Jorge A.; Henry, Christopher D.; Colgan, Joseph P.; John, David A.
2016-01-01
Zircon geochronology is a critical tool for establishing geologic ages and time scales of processes in the Earth's crust. However, for zircons compromised by open system behavior, achieving robust dates can be difficult. Chemical abrasion (CA) is a routine step prior to thermal ionization mass spectrometry (TIMS) dating of zircon to remove radiation-damaged parts of grains that may have experienced open system behavior and loss of radiogenic Pb. While this technique has been shown to improve the accuracy and precision of TIMS dating, its application to high-spatial resolution dating methods, such as secondary ion mass spectrometry (SIMS), is relatively uncommon. In our efforts to U-Pb date zircons from the late Eocene Caetano caldera by SIMS (SHRIMP-RG: sensitive high resolution ion microprobe, reverse geometry), some grains yielded anomalously young U-Pb ages that implicated Pb-loss and motivated us to investigate with a comparative CA and non-CA dating study. We present CA and non-CA 206Pb/238U ages and trace elements determined by SHRIMP-RG for zircons from three Caetano samples (Caetano Tuff, Redrock Canyon porphyry, and a silicic ring-fracture intrusion) and for R33 and TEMORA-2 reference zircons. We find that non-CA Caetano zircons have weighted mean or bimodal U-Pb ages that are 2–4% younger than CA zircons for the same samples. CA Caetano zircons have mean U-Pb ages that are 0.4–0.6 Myr older than the 40Ar/39Ar sanidine eruption age (34.00 ± 0.03 Ma; error-weighted mean, 2σ), whereas non-CA zircons have ages that are 0.7–1.3 Myr younger. U-Pb ages do not correlate with U (~ 100–800 ppm), Th (~ 50–300 ppm) or any other measured zircon trace elements (Y, Hf, REE), and CA and non-CA Caetano zircons define identical trace element ranges. No statistically significant difference in U-Pb age is observed for CA versus non-CA R33 or TEMORA-2 zircons. Optical profiler measurements of ion microprobe pits demonstrate consistent depths of ~ 1.6 μm for CA and non-CA Caetano, R33 and TEMORA-2 zircons, and do not indicate variations in secondary ion sputtering rates due to chemical or structural changes from the CA treatment. Our new data underscore the potential for cryptic Pb-loss to go unrecognized in other geologically young magmatic centers that do not have zircons with high U, statistically discordant isotope ratios, high common Pb, or metamict textures.
NASA Technical Reports Server (NTRS)
Donovan, Terence; Johnson, Linda; Klemm, Karl; Scheri, Rick; Bennett, Jean; Erickson, Jon; Dibrozolo, Filippo
1995-01-01
Two mirror designs developed for space applications were flown along with a standard mid-infrared design on the leading and trailing edges of the Long Duration Exposure Facility (LDEF). Preliminary observations of induced changes in optical performance of ZnS-coated mirrors and impact-related microstructural and microchemical effects are described in the proceedings of the First LDEF Post-Retrieval Symposium. In this paper, effects of the induced environment and meteoroid/debris impacts on mirror performance are described in more detail. Also, an analysis of reflectance spectra using the results of Auger and secondary ion mass spectroscopy (SIMS) profiling measurements are used to identify an optical-degradation mechanism for the ZnS-coated mirrors. Structural damage associated with a high-velocity impact on a (Si/Al2O3)-coated mirror was imaged optically and with scanning electron and atomic force microscopy (SEM and AFM). Scanning Auger and SIMS analysis provided chemical mapping of selected impact sites. The impact data suggest design and fabrication modifications for obtaining improved mechanical performance using a design variation identified in preflight laboratory simulations. Auger surface profile and SIMS imaging data verified the conclusion that secondary impacts are the source of contamination associated with the dendrites grown on the leading-edge ZnS-coated test samples. It was also found that dendrites can be grown in the laboratory by irradiating contaminated sites on a trailing-edge ZnS-coated sample with a rastered electron beam. These results suggest a mechanism for dendrite growth.
X-ray Photoelectron Spectroscopy of High-κ Dielectrics
NASA Astrophysics Data System (ADS)
Mathew, A.; Demirkan, K.; Wang, C.-G.; Wilk, G. D.; Watson, D. G.; Opila, R. L.
2005-09-01
Photoelectron spectroscopy is a powerful technique for the analysis of gate dielectrics because it can determine the elemental composition, the chemical states, and the compositional depth profiles non-destructively. The sampling depth, determined by the escape depth of the photoelectrons, is comparable to the thickness of current gate oxides. A maximum entropy algorithm was used to convert photoelectron collection angle dependence of the spectra to compositional depth profiles. A nitrided hafnium silicate film is used to demonstrate the utility of the technique. The algorithm balances deviations from a simple assumed depth profile against a calculated depth profile that best fits the angular dependence of the photoelectron spectra. A flow chart of the program is included in this paper. The development of the profile is also shown as the program is iterated. Limitations of the technique include the electron escape depths and elemental sensitivity factors used to calculate the profile. The technique is also limited to profiles that extend to the depth of approximately twice the escape depth. These limitations restrict conclusions to comparison among a family of similar samples. Absolute conclusions about depths and concentrations must be used cautiously. Current work to improve the algorithm is also described.
NASA Astrophysics Data System (ADS)
Yan, X. L.; Coetsee, E.; Wang, J. Y.; Swart, H. C.; Terblans, J. J.
2017-07-01
The polycrystalline Ni/Cu multilayer thin films consisting of 8 alternating layers of Ni and Cu were deposited on a SiO2 substrate by means of electron beam evaporation in a high vacuum. Concentration-depth profiles of the as-deposited multilayered Ni/Cu thin films were determined with Auger electron spectroscopy (AES) in combination with Ar+ ion sputtering, under various bombardment conditions with the samples been stationary as well as rotating in some cases. The Mixing-Roughness-Information depth (MRI) model used for the fittings of the concentration-depth profiles accounts for the interface broadening of the experimental depth profiling. The interface broadening incorporates the effects of atomic mixing, surface roughness and information depth of the Auger electrons. The roughness values extracted from the MRI model fitting of the depth profiling data agrees well with those measured by atomic force microscopy (AFM). The ion sputtering induced surface roughness during the depth profiling was accordingly quantitatively evaluated from the fitted MRI parameters with sample rotation and stationary conditions. The depth resolutions of the AES depth profiles were derived directly from the values determined by the fitting parameters in the MRI model.
Multiwavelength counterparts of the point sources in the Chandra Source Catalog
NASA Astrophysics Data System (ADS)
Reynolds, Michael; Civano, Francesca Maria; Fabbiano, Giuseppina; D'Abrusco, Raffaele
2018-01-01
The most recent release of the Chandra Source Catalog (CSC) version 2.0 comprises more than $\\sim$350,000 point sources, down to fluxes of $\\sim$10$^{-16}$ erg/cm$^2$/s, covering $\\sim$500 deg$^2$ of the sky, making it one of the best available X-ray catalogs to date. There are many reasons to have multiwavelength counterparts for sources, one such reason is that X-ray information alone is not enough to identify the sources and divide them between galactic and extragalactic origin, therefore multiwavelength data associated to each X-ray source is crucial for classification and scientific analysis of the sample. To perform this multiwavelength association, we are going to employ the recently released versatile tool NWAY (Salvato et al. 2017), based on a Bayesian algorithm for cross-matching multiple catalogs. NWAY allows the combination of multiple catalogs at the same time, provides a probability for the matches, even in case of non-detection due to different depth of the matching catalogs, and it can be used by including priors on the nature of the sources (e.g. colors, magnitudes, etc). In this poster, we are presenting the preliminary analysis using the CSC sources above the galactic plane matched to the WISE All-Sky catalog, SDSS, Pan-STARRS and GALEX.
NASA Astrophysics Data System (ADS)
Tremblay, L.; Caparros, J.; Leblanc, K.; Obernosterer, I.
2014-10-01
Natural iron fertilization of high-nutrient low-chlorophyll (HNLC) waters induces annually occurring spring phytoplankton blooms off Kerguelen Islands (Southern Ocean). To examine the origin and fate of particulate and dissolved organic matter (POM and DOM), D- and L-amino acids (AA) were quantified at bloom and HNLC stations. Total hydrolysable AA accounted for 21-25% of surface particulate organic carbon (%POCAA) at the bloom sites, but for 10% at the HNLC site. A marked decrease in %POCAA with depth was observed at the most productive stations leading to values between 3 and 5% below 300 m depth. AA contributed to only 0.9-4.4% of dissolved organic carbon (%DOCAA) at all stations. The only consistent vertical trend was observed at the most productive station (A3-2) where %DOCAA decreased from ∼2% in the surface waters to 0.9% near 300 m. These AA yields and other markers revealed that POM and DOM were more rapidly altered or mineralized at the bloom sites compared to the HNLC site. Different molecular markers indicated that POM mostly originated from diatoms and bacteria. The estimated average proportion of POM from intact phytoplankton cells in surface waters was 45% at the bloom station A3-2, but 14% at the HNLC site. Estimates based on D-AA yields indicated that ∼15% of POM and ∼30% of DOM was of bacterial origin (cells and cell fragments) at all stations. Surprisingly, the DOM in HNLC waters appeared less altered than the DOM from the bloom, had slightly higher dissolved AA concentrations, and showed no sign of alteration within the water column. Unfavorable conditions for bacterial degradation in HNLC regions can explain these findings. In contrast, large inputs of labile organic molecules and iron, likely stimulate the degradation of organic matter (priming effect) and the production of more recalcitrant DOM (microbial carbon pump) during iron-fertilized blooms.
Effects of SF6 plasma treatment on the properties of InGaZnO thin films
NASA Astrophysics Data System (ADS)
Choi, Jinsung; Bae, Byung Seong; Yun, Eui-Jung
2018-03-01
The effects of sulfur hexafluoride (SF6) plasma on the properties of amorphous InGaZnO (a-IGZO) thin films were examined. The properties of the a-IGZO thin films were characterized by Hall effect measurement, dynamic secondary ion mass spectroscopy (SIMS), and X-ray photoelectron spectroscopy (XPS). The IGZO thin films treated with SF6 plasma before annealing had a very high resistance mainly owing to the inclusion of S into the film surface, as evidenced by SIMS profiles. On the other hand, the samples treated with SF6 plasma after annealing showed better electrical properties with a Hall mobility of 10 cm2/(V·s) than the untreated samples or the samples SF6 plasma-treated before annealing. This was attributed to the increase in the number of oxygen vacancy defects in the a-IGZO thin films owing to the enhanced out-diffusion of O to the ambient and the increase in the number of F-related donor defects originating from the incorporation of a much larger amount of F than of S into the film surface, which were confirmed by XPS and SIMS.
Understanding heterogeneity in Genesis diamond-like carbon film using SIMS analysis of implants
Jurewicz, Amy J. G.; Burnett, Don S.; Rieck, Karen D.; ...
2017-07-05
An amorphous diamond-like carbon film deposited on silicon made at Sandia National Laboratory by pulsed laser deposition was one of several solar wind (SW) collectors used by the Genesis Mission (NASA Discovery Class Mission #5). The film was ~1 μm thick, amorphous, anhydrous, and had a high ratio of sp 3–sp 2 bonds (>50%). For 27 months of exposure to space at the first We passively irradiated lagrange point, the collectors, with SW (H fluence ~2 × 10 16 ions cm -2; He fluence ~8 × 10 14 ions cm -2). The radiation damage caused by the implanted H ionsmore » peaked at 12–14 nm below the surface of the film and that of He about 20–23 nm. To enable quantitative measurement of the SW fluences by secondary ion mass spectroscopy, minor isotopes of Mg ( 25Mg and 26Mg) were commercially implanted into flight-spare collectors at 75 keV and a fluence of 1 × 10 14 ions cm -2. Furthermore, the shapes of analytical depth profiles, the rate at which the profiles were sputtered by a given beam current, and the intensity of ion yields are used to characterize the structure of the material in small areas (~200 × 200 ± 50 μm). Data were consistent with the hypothesis that minor structural changes in the film were induced by SW exposure.« less
Understanding heterogeneity in Genesis diamond-like carbon film using SIMS analysis of implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jurewicz, Amy J. G.; Burnett, Don S.; Rieck, Karen D.
An amorphous diamond-like carbon film deposited on silicon made at Sandia National Laboratory by pulsed laser deposition was one of several solar wind (SW) collectors used by the Genesis Mission (NASA Discovery Class Mission #5). The film was ~1 μm thick, amorphous, anhydrous, and had a high ratio of sp 3–sp 2 bonds (>50%). For 27 months of exposure to space at the first We passively irradiated lagrange point, the collectors, with SW (H fluence ~2 × 10 16 ions cm -2; He fluence ~8 × 10 14 ions cm -2). The radiation damage caused by the implanted H ionsmore » peaked at 12–14 nm below the surface of the film and that of He about 20–23 nm. To enable quantitative measurement of the SW fluences by secondary ion mass spectroscopy, minor isotopes of Mg ( 25Mg and 26Mg) were commercially implanted into flight-spare collectors at 75 keV and a fluence of 1 × 10 14 ions cm -2. Furthermore, the shapes of analytical depth profiles, the rate at which the profiles were sputtered by a given beam current, and the intensity of ion yields are used to characterize the structure of the material in small areas (~200 × 200 ± 50 μm). Data were consistent with the hypothesis that minor structural changes in the film were induced by SW exposure.« less
Low-energy BF2, BCl2, and BBr2 implants for ultrashallow P+-N junctions
NASA Astrophysics Data System (ADS)
Nandan, S. R.; Agarwal, Vikas; Banerjee, Sanjay K.
1997-08-01
We have examined low energy BCl2 and BBr2 implants as a means of fabricating ultra-shallow P+-N junctions. Five keV and 9 keV BCl2 implants and 18 keV BBr2 implants have been compared to 5 keV BF2 implants to study the benefits of using these species. BCl2 and BBr2, being heavier species, have a lower projected range and produce more damage. The greater damage restricts channeling, resulting in shallower as-implanted profiles. The increased damage amorphizes the substrate at low implant doses which results in reduced transient enhanced diffusion (TED) during the post-implant anneal. Post-anneal SIMS profiles indicate a junction depth reduction of over 10 nm (at 5 X 1017 cm-3 background doping) for 5 keV BCl2 implants as compared to 5 keV BF2 implants. Annealed junctions as shallow as 10 nm have been obtained from the 18 keV BBr2 implants. The increased damage degrades the electrical properties of these junctions by enhancing the leakage current densities. BCl2 implanted junctions have leakage current densities of approximately 1 (mu) A/cm2 as compared to 10 nA/cm2 for the BF2 implants. BBr2 implants have a lower leakage density of approximately 50 nA/cm2. Low energy BBr2 implants offer an exciting alternative for fabricating low leakage, ultra-shallow P+-N junctions.
Aydin, Halit; Korte, Carsten; Janek, Jürgen
2013-01-01
The oxygen tracer diffusion coefficient describing transport along nano-/microscaled YSZ/Sc2O3 multilayers as a function of the thickness of the ion-conducting YSZ layers has been measured by isotope exchange depth profiling (IEDP), using secondary ion mass spectrometry (SIMS). The multilayer samples were prepared by pulsed laser deposition (PLD) on (0001) Al2O3 single crystalline substrates. The values for the oxygen tracer diffusion coefficient were analyzed as a combination of contributions from bulk and interface contributions and compared with results from YSZ/Y2O3-multilayers with similar microstructure. Using the Nernst–Einstein equation as the relation between diffusivity and electrical conductivity we find very good agreement between conductivity and diffusion data, and we exclude substantial electronic conductivity in the multilayers. The effect of hetero-interface transport can be well explained by a simple interface strain model. As the multilayer samples consist of columnar film crystallites with a defined interface structure and texture, we also discuss the influence of this particular microstructure on the interfacial strain. PMID:27877580
Analysis of simulated hypervelocity impacts on a titanium fuel tank from the Salyut 7 space station
NASA Astrophysics Data System (ADS)
Jantou, V.; McPhail, D. S.; Chater, R. J.; Kearsley, A.
2006-07-01
The aim of this project was to gain a better understanding of the microstructural effects of hypervelocity impacts (HVI) in titanium alloys. We investigated a titanium fuel tank recovered from the Russian Salyut 7 space station, which was launched on April 19, 1982 before being destroyed during an un-controlled re-entry in 1991, reportedly scattering debris over parts of South America. Several sections were cut out from the tank in order to undergo HVI simulations using a two-stage light gas gun. In addition, a Ti-6Al-4V alloy was studied for further comparison. The crater morphologies produced were successfully characterised using microscope-based white light interferometry (Zygo ® Corp, USA), while projectile remnants were identified via secondary ion mass spectrometry (SIMS). Microstructural alterations were investigated using focused ion beam (FIB) milling and depth profiling, as well as transmission electron microscopy (TEM). There was evidence of a very high density of dislocations in the vicinity of the crater. The extent of the deformation was localised in a region of about one to two radii of the impact craters. No notable differences were observed between the titanium alloys used during the hypervelocity impact tests.
Copper diffusion in Ti Si N layers formed by inductively coupled plasma implantation
NASA Astrophysics Data System (ADS)
Ee, Y. C.; Chen, Z.; Law, S. B.; Xu, S.; Yakovlev, N. L.; Lai, M. Y.
2006-11-01
Ternary Ti-Si-N refractory barrier films of 15 nm thick was prepared by low frequency, high density, inductively coupled plasma implantation of N into TixSiy substrate. This leads to the formation of Ti-N and Si-N compounds in the ternary film. Diffusion of copper in the barrier layer after annealing treatment at various temperatures was investigated using time-of-flight secondary ion mass spectrometer (ToF-SIMS) depth profiling, X-ray diffractometer (XRD), field emission scanning electron microscopy (FESEM), energy dispersive X-ray (EDX) and sheet resistance measurement. The current study found that barrier failure did not occur until 650 °C annealing for 30 min. The failure occurs by the diffusion of copper into the Ti-Si-N film to form Cu-Ti and Cu-N compounds. FESEM surface morphology and EDX show that copper compounds were formed on the ridge areas of the Ti-Si-N film. The sheet resistance verifies the diffusion of Cu into the Ti-Si-N film; there is a sudden drop in the resistance with Cu compound formation. This finding provides a simple and effective method of monitoring Cu diffusion in TiN-based diffusion barriers.
NASA Technical Reports Server (NTRS)
Panda, Binayak
2009-01-01
Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.
Synthesis of Al2O3 thin films using laser assisted spray pyrolysis (LASP)
NASA Astrophysics Data System (ADS)
Dhonge, Baban P.; Mathews, Tom; Tripura Sundari, S.; Krishnan, R.; Balamurugan, A. K.; Kamruddin, M.; Subbarao, R. V.; Dash, S.; Tyagi, A. K.
2013-01-01
The present study reports the development of a laser assisted ultrasonic spray pyrolysis technique and synthesis of dense optical alumina films using the same. In this technique ultrasonically generated aerosols of aluminum acetylacetonate dissolved in ethanol and a laser beam (Nd:YAG, CW, 1064 nm) were fed coaxially and concurrently through a quartz tube on to a hot substrate mounted on an X-Y raster stage. At the laser focused spot the precursor underwent solvent evaporation and solute sublimation followed by precursor vapor decomposition giving rise to oxide coating, the substrate is rastered to get large surface area coating. The surface morphology revealed coalescence of particles with increase in laser power. The observed particle sizes were 17 nm for films synthesized without laser and 18, 21 and 25 nm for films made with laser at 25, 38 and 50 W, respectively. Refractive index of the films synthesized increased from 1.56 to 1.62 as the laser power increased from 0 to 50 W. The stoichiometry of films was studied using XPS and the increase in interfacial layer thickness with laser power was observed from dynamic SIMS depth profiling and ellipsometry.
Aerosol loading in the Southeastern United States: reconciling surface and satellite observations
NASA Astrophysics Data System (ADS)
Ford, B.; Heald, C. L.
2013-09-01
We investigate the seasonality in aerosols over the Southeastern United States using observations from several satellite instruments (MODIS, MISR, CALIOP) and surface network sites (IMPROVE, SEARCH, AERONET). We find that the strong summertime enhancement in satellite-observed aerosol optical depth (AOD) (factor 2-3 enhancement over wintertime AOD) is not present in surface mass concentrations (25-55% summertime enhancement). Goldstein et al. (2009) previously attributed this seasonality in AOD to biogenic organic aerosol; however, surface observations show that organic aerosol only accounts for ∼35% of fine particulate matter (smaller than 2.5 μm in aerodynamic diameter, PM2.5) and exhibits similar seasonality to total surface PM2.5. The GEOS-Chem model generally reproduces these surface aerosol measurements, but underrepresents the AOD seasonality observed by satellites. We show that seasonal differences in water uptake cannot sufficiently explain the magnitude of AOD increase. As CALIOP profiles indicate the presence of additional aerosol in the lower troposphere (below 700 hPa), which cannot be explained by vertical mixing, we conclude that the discrepancy is due to a missing source of aerosols above the surface layer in summer.
Effect of nanoconfinement on the sputter yield in ultrathin polymeric films: Experiments and model
NASA Astrophysics Data System (ADS)
Cristaudo, Vanina; Poleunis, Claude; Delcorte, Arnaud
2018-06-01
This fundamental contribution on secondary ion mass spectrometry (SIMS) polymer depth-profiling by large argon clusters investigates the dependence of the sputter yield volume (Y) on the thickness (d) of ultrathin films as a function of the substrate nature, i.e. hard vs soft. For this purpose, thin films of polystyrene (PS) oligomers (∼4,000 amu) are spin-coated, respectively, onto silicon and poly (methyl methacrylate) supports and, then, bombarded by 10 keV Ar3000+ ions. The investigated thickness ranges from 15 to 230 nm. Additionally, the influence of the polymer molecular weight on Y(d) for PS thin films on Si is explored. The sputtering efficiency is found to be strongly dependent on the overlayer thickness, only in the case of the silicon substrate. A simple phenomenological model is proposed for the description of the thickness influence on the sputtering yield. Molecular dynamics (MD) simulations conducted on amorphous films of polyethylene-like oligomers of increasing thickness (from 2 to 20 nm), under comparable cluster bombardment conditions, predict a significant increase of the sputtering yield for ultrathin layers on hard substrates, induced by energy confinement in the polymer, and support our phenomenological model.
Oxygen Isotope Variability within Nautilus Shell Growth Bands
2016-01-01
Nautilus is often used as an analogue for the ecology and behavior of extinct externally shelled cephalopods. Nautilus shell grows quickly, has internal growth banding, and is widely believed to precipitate aragonite in oxygen isotope equilibrium with seawater. Pieces of shell from a wild-caught Nautilus macromphalus from New Caledonia and from a Nautilus belauensis reared in an aquarium were cast in epoxy, polished, and then imaged. Growth bands were visible in the outer prismatic layer of both shells. The thicknesses of the bands are consistent with previously reported daily growth rates measured in aquarium reared individuals. In situ analysis of oxygen isotope ratios using secondary ion mass spectrometry (SIMS) with 10 μm beam-spot size reveals inter- and intra-band δ18O variation. In the wild-caught sample, a traverse crosscutting 45 growth bands yielded δ18O values ranging 2.5‰, from +0.9 to -1.6 ‰ (VPDB), a range that is larger than that observed in many serial sampling of entire shells by conventional methods. The maximum range within a single band (~32 μm) was 1.5‰, and 27 out of 41 bands had a range larger than instrumental precision (±2 SD = 0.6‰). The results from the wild individual suggest depth migration is recorded by the shell, but are not consistent with a simple sinusoidal, diurnal depth change pattern. To create the observed range of δ18O, however, this Nautilus must have traversed a temperature gradient of at least ~12°C, corresponding to approximately 400 m depth change. Isotopic variation was also measured in the aquarium-reared sample, but the pattern within and between bands likely reflects evaporative enrichment arising from a weekly cycle of refill and replacement of the aquarium water. Overall, this work suggests that depth migration behavior in ancient nektonic mollusks could be elucidated by SIMS analysis across individual growth bands. PMID:27100183
Oxygen isotope variability within Nautilus shell growth bands
Linzmeier, Benjamin J.; Kozdon, Reinhard; Peters, Shanan E.; ...
2016-04-21
Nautilus is often used as an analogue for the ecology and behavior of extinct externally shelled cephalopods. Nautilus shell grows quickly, has internal growth banding, and is widely believed to precipitate aragonite in oxygen isotope equilibrium with seawater. Pieces of shell from a wild-caught Nautilus macromphalus from New Caledonia and from a Nautilus belauensis reared in an aquarium were cast in epoxy, polished, and then imaged. Growth bands were visible in the outer prismatic layer of both shells. The thicknesses of the bands are consistent with previously reported daily growth rates measured in aquarium reared individuals. In situ analysis ofmore » oxygen isotope ratios using secondary ion mass spectrometry (SIMS) with 10 μm beam-spot size reveals inter- and intra-band δ 18O variation. In the wild-caught sample, a traverse crosscutting 45 growth bands yielded δ 18O values ranging 2.5‰, from +0.9 to -1.6 ‰ (VPDB), a range that is larger than that observed in many serial sampling of entire shells by conventional methods. The maximum range within a single band (~32 μm) was 1.5‰, and 27 out of 41 bands had a range larger than instrumental precision (±2 SD = 0.6‰). The results from the wild individual suggest depth migration is recorded by the shell, but are not consistent with a simple sinusoidal, diurnal depth change pattern. In addition, to create the observed range of δ 18O, however, this Nautilus must have traversed a temperature gradient of at least ~12°C, corresponding to approximately 400 m depth change. Isotopic variation was also measured in the aquarium-reared sample, but the pattern within and between bands likely reflects evaporative enrichment arising from a weekly cycle of refill and replacement of the aquarium water. Overall, this work suggests that depth migration behavior in ancient nektonic mollusks could be elucidated by SIMS analysis across individual growth bands.« less
NASA Astrophysics Data System (ADS)
Bart, Gerhard; Aerne, Ernst Tino; Burri, Martin; Zwicky, Hans-Urs
1986-11-01
Cladding carburization during irradiation of advanced mixed uranium plutonium carbide fast breeder reactor fuel is possibly a life limiting fuel pin factor. The quantitative assessment of such clad carbon embrittlement is difficult to perform by electron microprobe analysis because of sample surface contamination, and due to the very low energy of the carbon K α X-ray transition. The work presented here describes a method developed at the Swiss Federal Institute for Reactor Research (EIR) to use shielded secondary ion mass spectrometry (SIMS) as an accurate tool to determine radial distribution profiles of carbon in radioactive stainless steel fuel pin cladding. Compared with nuclear microprobe analysis (NMA) [1], which is also an accurate method for carbon analysis, the SIMS method distinguishes itself by its versatility for simultaneous determination of additional impurities.
Depth profile measurement with lenslet images of the plenoptic camera
NASA Astrophysics Data System (ADS)
Yang, Peng; Wang, Zhaomin; Zhang, Wei; Zhao, Hongying; Qu, Weijuan; Zhao, Haimeng; Asundi, Anand; Yan, Lei
2018-03-01
An approach for carrying out depth profile measurement of an object with the plenoptic camera is proposed. A single plenoptic image consists of multiple lenslet images. To begin with, these images are processed directly with a refocusing technique to obtain the depth map, which does not need to align and decode the plenoptic image. Then, a linear depth calibration is applied based on the optical structure of the plenoptic camera for depth profile reconstruction. One significant improvement of the proposed method concerns the resolution of the depth map. Unlike the traditional method, our resolution is not limited by the number of microlenses inside the camera, and the depth map can be globally optimized. We validated the method with experiments on depth map reconstruction, depth calibration, and depth profile measurement, with the results indicating that the proposed approach is both efficient and accurate.
Xenon migration in UO2 under irradiation studied by SIMS profilometry
NASA Astrophysics Data System (ADS)
Marchand, B.; Moncoffre, N.; Pipon, Y.; Bérerd, N.; Garnier, C.; Raimbault, L.; Sainsot, P.; Epicier, T.; Delafoy, C.; Fraczkiewicz, M.; Gaillard, C.; Toulhoat, N.; Perrat-Mabilon, A.; Peaucelle, C.
2013-09-01
During Pressurized Water Reactor operation, around 25% of the created Fission Products (FP) are Xenon and Krypton. They have a low solubility in the nuclear fuel and can either (i) agglomerate into bubbles which induce mechanical stress in the fuel pellets or (ii) be released from the pellets, increasing the pressure within the cladding and decreasing the thermal conductivity of the gap between pellets and cladding. After fifty years of studies on the nuclear fuel, all mechanisms of Fission Gas Release (FGR) are still not fully understood. This paper aims at studying the FGR mechanisms by decoupling thermal and irradiation effects and by assessing the Xenon behavior for the first time by profilometry. Samples are first implanted with 136Xe at 800 keV corresponding to a projected range of 140 nm. They are then either annealed in the temperature range 1400-1600 °C, or irradiated with heavy energy ions (182 MeV Iodine) at Room Temperature (RT), 600 °C or 1000 °C. Depth profiles of implanted Xenon in UO2 are determined by Secondary Ion Mass Spectrometry (SIMS). It is shown that Xenon is mobile during irradiation at 1000 °C. In contrast, thermal treatments do not induce any Xenon migration process: these results are correlated to the formation of Xenon bubbles observed by Transmission Electron Microscopy. At depths lower than about 40 nm (zone 1), no bubbles are observed, At depths in between 40 nm and 110 nm (zone 2), a large number of small bubbles (around 2 nm in diameter) can be observed. By comparing with the SRIM profile, it appears that this area corresponds to the maximum of the defect profile, The third zone displays two bubble populations. The first population has the same size than the bubbles present in zone 2. The bubble size of the second population is significantly larger (up to around 10 nm). A STEM micrograph is presented in Fig. 4. It highlights the Xenon bubbles more clearly. It appears that the largest bubbles are located mainly near dislocations which are predominantly in zone 3. TEM micrographs obtained on the samples annealed at 1400 °C (not shown here) show only small sized bubbles (around 2 nm). The presence of these bubbles could explain that no Xenon migration occurs even after annealing at 1600 °C during 16 h. Moreover, concerning Xe thermal resolution, this can only occur if the bubble is overpressurized [21]. It was shown by Martin et al. [22] that at high temperature (over 1400 °C) non pressurized aggregates are observed. So in our experiments, Xe thermal resolution is unlikely.The bubble sizes measured after 1400 °C and 1600 °C annealing are in agreement with literature data, in particular, with those of Michel et al. [23] obtained in Xenon implanted UO2 samples. Indeed they observed 1 nm sized bubbles at 600 °C, which could reach 3 nm at 1400 °C. Either conditions of the Neumann type for which the surface is impermeable which means that the Xenon flux is equal to zero and can be expressed by Eq. (2). {dC}/{dx}|surface=0 Or conditions of the Dirichlet type with a constant Xenon concentration at the surface expressed by Eq. (3). C(0,t)=constant We chose Neumann conditions since we observed a slight increase of Xenon concentration at the surface for the profiles of the samples irradiated at 600 °C and at 1000 °C. In order to simulate the evolution of the Xenon concentration profiles, as-implanted profiles were first fitted with Gaussian shaped curves. The evolution of these curves was then simulated by using the one dimensional finite difference method. Therefore, the total depth profile was discretized into 1.5 nm slices. D, v, k parameters were thus deduced from successive iterations until the final profile is correctly fitted. It is important to keep in mind that each migration mechanism induces a particular modification of the profile shape: a broadening is characteristic of a diffusion process, a profile shift is significant of a transport process and an area decrease means a release mechanism. Consequently, only one set of parameters can allow a correct fit of the final profile.This method was applied for the sample irradiated at 1000 °C and the fitted spectrum is presented in Fig. 6. The obtained values are respectively: D=9.5×10-16 cm s, v=3.1×10-10 cm s and k=2.5×10-5 s. The deduced apparent diffusion coefficient (9.5 × 10-16 cm2 s-1) is one order of magnitude higher than the one given by Turnbull [25] who studied the fission gas release of in-pile irradiated UO2 pellets and who found around 1 × 10-16 cm2 s-1 at 1000 °C.The differences between our results and Turnbull results could be mainly explained by the fact that Turnbull deduced his results from in-pile experiments whereas we performed irradiation on UO2 samples implanted with Xenon. More precisely, Turnbull experiments were made with a neutron flux of 4 × 1016 m-2 s-1 generating fission products with a wide energy range up to 110 MeV. In our experiments, irradiation was performed with Iodine ions of a single energy (186 MeV) with a pretty high flux of 5 × 1019 I m-2 s-1.Moreover, Turnbull measured Xe release and had to use the Booth model to determine Xe diffusion coefficient. In this last model, several hypotheses are made, the major ones being a spherical shape of grains and no possible accumulation of Xenon at the grain surface. Our diffusion coefficient is obtained after solving the Fick's equation without any hypothesis on the grain geometry.
Interpreting Repeated Temperature-Depth Profiles for Groundwater Flow
NASA Astrophysics Data System (ADS)
Bense, Victor F.; Kurylyk, Barret L.; van Daal, Jonathan; van der Ploeg, Martine J.; Carey, Sean K.
2017-10-01
Temperature can be used to trace groundwater flows due to thermal disturbances of subsurface advection. Prior hydrogeological studies that have used temperature-depth profiles to estimate vertical groundwater fluxes have either ignored the influence of climate change by employing steady-state analytical solutions or applied transient techniques to study temperature-depth profiles recorded at only a single point in time. Transient analyses of a single profile are predicated on the accurate determination of an unknown profile at some time in the past to form the initial condition. In this study, we use both analytical solutions and a numerical model to demonstrate that boreholes with temperature-depth profiles recorded at multiple times can be analyzed to either overcome the uncertainty associated with estimating unknown initial conditions or to form an additional check for the profile fitting. We further illustrate that the common approach of assuming a linear initial temperature-depth profile can result in significant errors for groundwater flux estimates. Profiles obtained from a borehole in the Veluwe area, Netherlands in both 1978 and 2016 are analyzed for an illustrative example. Since many temperature-depth profiles were collected in the late 1970s and 1980s, these previously profiled boreholes represent a significant and underexploited opportunity to obtain repeat measurements that can be used for similar analyses at other sites around the world.
Aaboud, M.; Aad, G.; Abbott, B.; ...
2018-02-22
Here, a search for the direct production of charginos and neutralinos in final states with at least two hadronically decaying tau leptons is presented. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of 36.1fb -1, recorded with the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy of 13 TeV. No significant deviation from the expected Standard Model background is observed. Limits are derived in scenarios ofmore » $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ pair production and of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ production in simplified models where the neutralinos and charginos decay solely via intermediate left-handed staus and tau sneutrinos, and the mass of the $$\\sim\\atop{\\tau}_L$$ state is set to be halfway between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Chargino masses up to 630 GeV are excluded at 95% confidence level in the scenario of direct production of $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ for a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Common $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ masses up to 760 GeV are excluded in the case of production of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$-\\atop{1}$$ assuming a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Exclusion limits for additional benchmark scenarios with large and small mass-splitting between the Open image in new window $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$ are also studied by varying the $$\\sim\\atop{\\tau}_L$$ mass between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaboud, M.; Aad, G.; Abbott, B.
Here, a search for the direct production of charginos and neutralinos in final states with at least two hadronically decaying tau leptons is presented. The analysis uses a dataset of pp collisions corresponding to an integrated luminosity of 36.1fb -1, recorded with the ATLAS detector at the Large Hadron Collider at a centre-of-mass energy of 13 TeV. No significant deviation from the expected Standard Model background is observed. Limits are derived in scenarios ofmore » $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ pair production and of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ production in simplified models where the neutralinos and charginos decay solely via intermediate left-handed staus and tau sneutrinos, and the mass of the $$\\sim\\atop{\\tau}_L$$ state is set to be halfway between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Chargino masses up to 630 GeV are excluded at 95% confidence level in the scenario of direct production of $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$\\bar{1}$$ for a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Common $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ masses up to 760 GeV are excluded in the case of production of $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$0\\atop{2}$$ and $$\\sim\\atop{\\chi}$$ $$+\\atop{1}$$ $$\\sim\\atop{\\chi}$$ $$-\\atop{1}$$ assuming a massless $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$. Exclusion limits for additional benchmark scenarios with large and small mass-splitting between the Open image in new window $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$ are also studied by varying the $$\\sim\\atop{\\tau}_L$$ mass between the masses of the $$\\sim\\atop{\\chi}$$ $$±\\atop{1}$$ and the $$\\sim\\atop{\\chi}$$ $$0\\atop{1}$$.« less
NASA Astrophysics Data System (ADS)
Jollands, Michael C.; Hanger, Brendan J.; Yaxley, Gregory M.; Hermann, Jörg; Kilburn, Matthew R.
2018-01-01
Rare garnet crystals from a peridotite xenolith from the Wesselton kimberlite, South Africa, have distinct zones related to two separate episodes of mantle metasomatism. The garnet cores were firstly depleted through melt extraction, then equilibrated during metasomatism by a potentially diamond-forming carbonate-bearing or proto-kimberlitic fluid at 1100-1300 °C and 4.5-5.5 GPa. The garnet rim chemistry, in contrast, is consistent with later overgrowth in equilibrium with a kimberlite at around 1025 ± 25 °C and 4.2 ± 0.5 GPa. This suggests that the rock was physically moved upwards by up to tens of kilometres between the two metasomatic episodes. Preserved high Ca, Al and Cr contents in orthopyroxenes suggest this uplift was tectonic, rather than magmatic. Diffusion profiles were measured over the transitions between garnet cores and rims using electron microprobe (Mg, Ca, Fe for modelling, plus Cr, Mn, Ti, Na, Al) and nano Secondary Ion Mass Spectrometry (NanoSIMS; 89Y, along with 23Na, Ca, Cr, Fe, Mn and Ti) analyses. The short profile lengths (generally <10 μm) and low Y concentrations (0.2-60 ppm) make the NanoSIMS approach preferable. Diffusion profiles at the interface between the zones yield constraints on the timescale between the second metasomatic event and eruption of the kimberlite magma that brought the xenolith to the surface. The time taken to form the diffusion profiles is on the order of 25 days to 400 yr, primarily based on modelling of Y diffusion along with Ca, Fe and Mg (multicomponent diffusion) profiles. These timescales are too long to be produced by the interaction of the mantle xenolith with the host kimberlite magma during a single-stage ascent to the crust (hours to days). The samples offer a rare opportunity to study metasomatic processes associated with failed eruption attempts in the cratonic lithosphere.
Dowsett, D; Wirtz, T
2017-09-05
The development of a high resolution elemental imaging platform combining coregistered secondary ion mass spectrometry and high resolution secondary electron imaging is reported. The basic instrument setup and operation are discussed and in situ image correlation is demonstrated on a lithium titanate and magnesium oxide nanoparticle mixture. The instrument uses both helium and neon ion beams generated by a gas field ion source to irradiate the sample. Both secondary electrons and secondary ions may be detected. Secondary ion mass spectrometry (SIMS) is performed using an in-house developed double focusing magnetic sector spectrometer with parallel detection. Spatial resolutions of 10 nm have been obtained in SIMS mode. Both the secondary electron and SIMS image data are very surface sensitive and have approximately the same information depth. While the spatial resolutions are approximately a factor of 10 different, switching between the different images modes may be done in situ and extremely rapidly, allowing for simple imaging of the same region of interest and excellent coregistration of data sets. The ability to correlate mass spectral images on the 10 nm scale with secondary electron images on the nanometer scale in situ has the potential to provide a step change in our understanding of nanoscale phenomena in fields from materials science to life science.
ON-SITE SOLID PHRASE EXTRACTION AND LABORATORY ...
Fragrance materials, such as synthetic musks in aqueous samples, are normally analyzed by GC/MS in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. A I -L sample, however, usually provides too little analyte for full-scan data acquisition. An on-site extraction method for extracting synthetic musks from 60 L of wastewater effluent has been developed. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for various synthetic musk compounds. Quantification of these compounds was conveniently achieved from the full-scan data directly, without preparing SIM descriptors for each compound to acquire SIM data. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-sol
IN SITU SOLID-PHASE EXTRACTION AND ANALYSIS OF ...
Fragrance materials, such as synthetic musks in aqueous samples, are normally analyzed by GC/MS in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of 1-L samples. A 1-L sample, however, usually provides too little analyte for full-scan data acquisition.We have developed an on-site extraction method for extracting synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for various synthetic musk compounds. Quantification of these compounds was conveniently achieved from the full-scan data directly, without preparing SIM descriptors for each compound to acquire SIM data. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-s
Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass
Suratwala, Tayyab; Steele, William; Wong, Lana; ...
2015-05-19
The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increasedmore » with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.« less
NASA Astrophysics Data System (ADS)
Kakinuma, Hiroaki; Mohri, Mikio; Tsuruoka, Taiji
1994-01-01
We have investigated phosphorus doping using an electron cyclotron resonance (ECR) plasma, for application to the poly-Si driving circuits of liquid crystal displays or image sensors. The PH3/He was ionized and accelerated to poly-Si and c-Si substrates with a self bias of -220 V. The P concentration, as detected by secondary ion mass spectroscopy (SIMS), is ˜5×1021 cm-3 at the surface, which decayed to ˜1017 cm-3 within 50 100 nm depth. The surface is found to be etched during doping. The etching is restored by adding a small amount of SiH4 and the sheet resistance R s decreases. The optimized as-irradiated R s is ˜ 1× 105 Ω/\\Box and 1.7× 102 Ω/\\Box for poly-Si and (110) c-Si, respectively. The dependence of R s on the substrates and the anomalous diffusion constants derived from SIMS are also discussed.
H-mode plasmas at very low aspect ratio on the Pegasus Toroidal Experiment
Thome, Kathleen E.; Bongard, Michael W.; Barr, Jayson L.; ...
2016-09-30
H-mode is obtained atmore » $$A\\sim 1.2$$ in the Pegasus Toroidal Experiment via Ohmic heating, high-field-side fueling, and low edge recycling in both limited and diverted magnetic topologies. These H-mode plasmas show the formation of edge current and pressure pedestals and a doubling of the energy confinement time to $${{H}_{98y,2}}\\sim 1$$ . The L–H power threshold $${{P}_{\\text{LH}}}$$ increases with density, and there is no $${{P}_{\\text{LH}}}$$ minimum observed in the attainable density space. The power threshold is equivalent in limited and diverted plasmas, consistent with the FM3 model. However, the measured $${{P}_{\\text{LH}}}$$ is $$\\sim 15\\,\\,\\times $$ higher than that predicted by conventional International Tokamak Physics Activity (ITPA) scalings, and $${{P}_{\\text{LH}}}/{{P}_{\\text{ITPA}08}}$$ increases as $$A\\to 1$$ . Small ELMs are present at low input power $${{P}_{\\text{IN}}}\\sim {{P}_{\\text{LH}}}$$ , with toroidal mode number $$n\\leqslant 4$$ . At $${{P}_{\\text{IN}}}\\gg {{P}_{\\text{LH}}}$$ , they transition to large ELMs with intermediate 5 < n < 15. The dominant-n component of a large ELM grows exponentially, while other components evolve nonlinearly and can damp prior to the crash. Direct measurements of the current profile in the pedestal region show that both ELM types exhibit a generation of a current-hole, followed by a pedestal recovery. Large ELMs are shown to further expel a current-carrying filament. Small ELM suppression via injection of low levels of helical current into the edge plasma region is also indicated.« less
VLSI Design, Parallel Computation and Distributed Computing
1991-09-30
I U1 TA 3 Daniel Mleitman U. : C ..( -_. .. .s .. . . . . Tom Leighton David Shmoys . ........A ,~i ;.t , 77 Michael Sipser , Di.,t a-., Eva Tardos...Leighton and Plaxton on the construction of a sim- ple c log .- depth circuit (where c < 7.5) that sorts a random permutation with very high probability...puting iPOD( ). Aug-ust 1992. Vancouver. British Columbia (to appear). 20. B 1Xti~ c .. U(.ii. 1. Gopal. M. [Kaplan and S. Kutten, "Distributed Control for
Depth profiling analysis of solar wind helium collected in diamond-like carbon film from Genesis
Bajo, Ken-ichi; Olinger, Chad T.; Jurewicz, Amy J.G.; ...
2015-01-01
The distribution of solar-wind ions in Genesis mission collectors, as determined by depth profiling analysis, constrains the physics of ion solid interactions involving the solar wind. Thus, they provide an experimental basis for revealing ancient solar activities represented by solar-wind implants in natural samples. We measured the first depth profile of ⁴He in a collector; the shallow implantation (peaking at <20 nm) required us to use sputtered neutral mass spectrometry with post-photoionization by a strong field. The solar wind He fluence calculated using depth profiling is ~8.5 x 10¹⁴ cm⁻². The shape of the solar wind ⁴He depth profile ismore » consistent with TRIM simulations using the observed ⁴He velocity distribution during the Genesis mission. It is therefore likely that all solar-wind elements heavier than H are completely intact in this Genesis collector and, consequently, the solar particle energy distributions for each element can be calculated from their depth profiles. Ancient solar activities and space weathering of solar system objects could be quantitatively reproduced by solar particle implantation profiles.« less
Using UAVSAR to Estimate Creep Along the Superstition Hills Fault, Southern California
NASA Astrophysics Data System (ADS)
Donnellan, A.; Parker, J. W.; Pierce, M.; Wang, J.
2012-12-01
UAVSAR data were first acquired over the Salton Trough region, just north of the Mexican border in October 2009. Second passes of data were acquired on 12 and 13 April 2010, about one week following the 5 April 2010 M 7.2 El Mayor - Cucapah earthquake. The earthquake resulted in creep on several faults north of the main rupture, including the Yuha, Imperial, and Superstition Hills faults. The UAVSAR platform acquires data about every six meters in swaths about 15 km wide. Tropospheric effects and residual aircraft motion contribute to error in the estimation of surface deformation in the Repeat Pass Interferometry products. The Superstition Hills fault shows clearly in the associated radar interferogram; however, error in the data product makes it difficult to infer deformation from long profiles that cross the fault. Using the QuakeSim InSAR Profile tool we extracted line of site profiles on either side of the fault delineated in the interferogram. We were able to remove much of the correlated error by differencing profiles 250 m on either side of the fault. The result shows right-lateral creep of 1.5±.4 mm along the northern 7 km of the fault in the interferogram. The amount of creep abruptly changes to 8.4±.4 mm of right lateral creep along at least 9 km of the fault covered in the image to the south. The transition occurs within less than 100 m along the fault. We also extracted 2 km long line of site profiles perpendicular to this section of the fault. Averaging these profiles shows a step across the fault of 14.9±.3 mm with greater creep on the order of 20 mm on the northern two profiles and lower creep of about 10 mm on the southern two profiles. Nearby GPS stations P503 and P493 are consistent with this result. They also confirm that the creep event occurred at the time of the El Mayor - Cucapah earthquake. By removing regional deformation resulting from the main rupture we were able to invert for the depth of creep from the surface. Results indicate that the slip occurred from the surface to 10-20 km, not shallowly, as previously suggested.
siMS Score: Simple Method for Quantifying Metabolic Syndrome.
Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna
2016-01-01
To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130-HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * family history of cardio/cerebro-vascular events (event = 1.2, no event = 1). A sample of 528 obese and non-obese participants was used to validate siMS score and siMS risk score. Scores calculated as sum of z-scores (each component of metabolic syndrome regressed with age and gender) and sum of scores derived from principal component analysis (PCA) were used for evaluation of siMS score. Variants were made by replacing glucose with HOMA in calculations. Framingham score was used for evaluation of siMS risk score. Correlation between siMS score with sum of z-scores and weighted sum of factors of PCA was high (r = 0.866 and r = 0.822, respectively). Correlation between siMS risk score and log transformed Framingham score was medium to high for age groups 18+,30+ and 35+ (0.835, 0.707 and 0.667, respectively). siMS score and siMS risk score showed high correlation with more complex scores. Demonstrated accuracy together with superior simplicity and the ability to evaluate and follow-up individual patients makes siMS and siMS risk scores very convenient for use in clinical practice and research as well.
Hybrid Organic/Inorganic Materials Depth Profiling Using Low Energy Cesium Ions
NASA Astrophysics Data System (ADS)
Noël, Céline; Houssiau, Laurent
2016-05-01
The structures developed in organic electronics, such as organic light emitting diodes (OLEDs) or organic photovoltaics (OPVs) devices always involve hybrid interfaces, joining metal or oxide layers with organic layers. No satisfactory method to probe these hybrid interfaces physical chemistry currently exists. One promising way to analyze such interfaces is to use in situ ion beam etching, but this requires ion beams able to depth profile both inorganic and organic layers. Mono- or diatomic ion beams commonly used to depth profile inorganic materials usually perform badly on organics, while cluster ion beams perform excellently on organics but yield poor results when organics and inorganics are mixed. Conversely, low energy Cs+ beams (<500 eV) allow organic and inorganic materials depth profiling with comparable erosion rates. This paper shows a successful depth profiling of a model hybrid system made of metallic (Au, Cr) and organic (tyrosine) layers, sputtered with 500 eV Cs+ ions. Tyrosine layers capped with metallic overlayers are depth profiled easily, with high intensities for the characteristic molecular ions and other specific fragments. Metallic Au or Cr atoms are recoiled into the organic layer where they cause some damage near the hybrid interface as well as changes in the erosion rate. However, these recoil implanted metallic atoms do not appear to severely degrade the depth profile overall quality. This first successful hybrid depth profiling report opens new possibilities for the study of OLEDs, organic solar cells, or other hybrid devices.
NASA Astrophysics Data System (ADS)
Hanrieder, Jörg; Ewing, Andrew G.
2014-06-01
Amyotrophic lateral sclerosis (ALS) is a devastating, rapidly progressing disease of the central nervous system that is characterized by motor neuron degeneration in the brain stem and the spinal cord. We employed time of flight secondary ion mass spectrometry (ToF-SIMS) to profile spatial lipid- and metabolite- regulations in post mortem human spinal cord tissue from ALS patients to investigate chemical markers of ALS pathogenesis. ToF-SIMS scans and multivariate analysis of image and spectral data were performed on thoracic human spinal cord sections. Multivariate statistics of the image data allowed delineation of anatomical regions of interest based on their chemical identity. Spectral data extracted from these regions were compared using two different approaches for multivariate statistics, for investigating ALS related lipid and metabolite changes. The results show a significant decrease for cholesterol, triglycerides, and vitamin E in the ventral horn of ALS samples, which is presumably a consequence of motor neuron degeneration. Conversely, the biogenic mediator lipid lysophosphatidylcholine and its fragments were increased in ALS ventral spinal cord, pointing towards neuroinflammatory mechanisms associated with neuronal cell death. ToF-SIMS imaging is a promising approach for chemical histology and pathology for investigating the subcellular mechanisms underlying motor neuron degeneration in amyotrophic lateral sclerosis.
Visualizing Intrapopulation Hematopoietic Cell Heterogeneity with Self-Organizing Maps of SIMS Data.
Mirshafiee, Vahid; Harley, Brendan A C; Kraft, Mary L
2018-05-07
Characterization of the heterogeneity within stem cell populations, which affects their differentiation potential, is necessary for the design of artificial cultures for stem cell expansion. In this study, we assessed whether self-organizing maps (SOMs) of single-cell time-of-flight secondary ion mass spectrometry (TOF-SIMS) data provide insight into the spectral, and thus the related functional heterogeneity between and within three hematopoietic cell populations. SOMs were created of TOF-SIMS data from individual hematopoietic stem and progenitor cells (HSPCs), lineage-committed common lymphoid progenitors (CLPs), and fully differentiated B cells that had been isolated from murine bone marrow via conventional flow cytometry. The positions of these cells on the SOMs and the spectral variation between adjacent map units, shown on the corresponding unified distance matrix (U-matrix), indicated the CLPs exhibited the highest intrapopulation spectral variation, regardless of the age of the donor mice. SOMs of HSPCs, CLPs, and B cells isolated from young and old mice using the same surface antigen profiles revealed the HSPCs exhibited the most age-related spectral variation, whereas B cells exhibited the least. These results demonstrate that SOMs of single-cell spectra enable characterizing the heterogeneity between and within cell populations that lie along distinct differentiation pathways.
Analysis techniques for tracer studies of oxidation. M. S. Thesis Final Report
NASA Technical Reports Server (NTRS)
Basu, S. N.
1984-01-01
Analysis techniques to obtain quantitative diffusion data from tracer concentration profiles were developed. Mass balance ideas were applied to determine the mechanism of oxide growth and to separate the fraction of inward and outward growth of oxide scales. The process of inward oxygen diffusion with exchange was theoretically modelled and the effect of lattice diffusivity, grain boundary diffusivity and grain size on the tracer concentration profile was studied. The development of the tracer concentration profile in a growing oxide scale was simulated. The double oxidation technique was applied to a FeCrAl-Zr alloy using 0-18 as a tracer. SIMS was used to obtain the tracer concentration profile. The formation of lacey oxide on the alloy was discussed. Careful consideration was given to the quality of data required to obtain quantitative information.
Mohamed, Maha Tarek; Abuelezz, Sally A; Atalla, Suzi Sobhy; El Aziz, Lobna Fouad Abd; Gorge, Sonia Salib
2017-05-01
Epidemiological studies suggest a possible link between osteoporosis and cardiovascular diseases. Mevalonate pathway was pointed to as a part of this link. This study was done to investigate the effects of Alendronate (Al) and Simvastatin (Sim), both act on the mevalonate pathway, on osteoporosis, dyslipidemia and atherosclerotic changes in ovariectomized (OVX) rats fed high fat diet (HFD). 60 female albino rats were equally divided into 5 groups: control sham, OVX-HFD untreated, OVX -HFD treated with Al (3mg/kg/d) or/and Sim (6mg/kg/d). Treatments were taken for 4 weeks by oral gavage and were started 8 weeks after ovariectomy. OVX-HFD untreated group exhibited a significant negative alteration in lipid profile and on different bone markers e.g. alkaline phosphatase, hydroxyproline and osteocalcin. A significant increase in body weights and on serum levels of TNFα, iNOS and leptin were also found compared to control sham group. Vascular reactivity studies revealed a significant decrease in effective concentration 50 of phenylephrine and in acetylcholine% of relaxation and a significant increase in maximum contractile response of phenylephrine. The atherosclerotic and osteoporotic changes were further confirmed histopathologically. Treatment of OVX-HFD with Al or/and Sim significantly improved these deleterious effects compared to OVX-HFD untreated group. Comparing the combination therapy versus the mono-therapy exhibited a significant improvement in different tested parameters which came in favor of the combination therapy. Al and Sim have anti-osteoporotic, anti-dyslipidemic and anti-atherosclerotic beneficial effects. Their combination has more promising effects in treatment of osteoporosis, dyslipidemia and atherosclerosis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Inochkin, F. M.; Pozzi, P.; Bezzubik, V. V.; Belashenkov, N. R.
2017-06-01
Superresolution image reconstruction method based on the structured illumination microscopy (SIM) principle with reduced and simplified pattern set is presented. The method described needs only 2 sinusoidal patterns shifted by half a period for each spatial direction of reconstruction, instead of the minimum of 3 for the previously known methods. The method is based on estimating redundant frequency components in the acquired set of modulated images. Digital processing is based on linear operations. When applied to several spatial orientations, the image set can be further reduced to a single pattern for each spatial orientation, complemented by a single non-modulated image for all the orientations. By utilizing this method for the case of two spatial orientations, the total input image set is reduced up to 3 images, providing up to 2-fold improvement in data acquisition time compared to the conventional 3-pattern SIM method. Using the simplified pattern design, the field of view can be doubled with the same number of spatial light modulator raster elements, resulting in a total 4-fold increase in the space-time product. The method requires precise knowledge of the optical transfer function (OTF). The key limitation is the thickness of object layer that scatters or emits light, which requires to be sufficiently small relatively to the lens depth of field. Numerical simulations and experimental results are presented. Experimental results are obtained on the SIM setup with the spatial light modulator based on the 1920x1080 digital micromirror device.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heo, Sung; College of Information and Communication Engineering, Sungkyunkwan University, Cheoncheon-dong 300, Jangan-gu, Suwon 440-746; Lee, Hyung-Ik
2015-06-29
To investigate the band gap profile of Cu(In{sub 1−x},Ga{sub x})(Se{sub 1−y}S{sub y}){sub 2} of various compositions, we measured the band gap profile directly as a function of in-depth using high-resolution reflection energy loss spectroscopy (HR-REELS), which was compared with the band gap profile calculated based on the auger depth profile. The band gap profile is a double-graded band gap as a function of in-depth. The calculated band gap obtained from the auger depth profile seems to be larger than that by HR-REELS. Calculated band gaps are to measure the average band gap of the spatially different varying compositions with respectmore » to considering its void fraction. But, the results obtained using HR-REELS are to be affected by the low band gap (i.e., out of void) rather than large one (i.e., near void). Our findings suggest an analytical method to directly determine the band gap profile as function of in-depth.« less
Structural analysis of poly-SUMO chain recognition by the RNF4-SIMs domain.
Kung, Camy C-H; Naik, Mandar T; Wang, Szu-Huan; Shih, Hsiu-Ming; Chang, Che-Chang; Lin, Li-Ying; Chen, Chia-Lin; Ma, Che; Chang, Chi-Fon; Huang, Tai-Huang
2014-08-15
The E3 ubiquitin ligase RNF4 (RING finger protein 4) contains four tandem SIM [SUMO (small ubiquitin-like modifier)-interaction motif] repeats for selective interaction with poly-SUMO-modified proteins, which it targets for degradation. We employed a multi-faceted approach to characterize the structure of the RNF4-SIMs domain and the tetra-SUMO2 chain to elucidate the interaction between them. In solution, the SIM domain was intrinsically disordered and the linkers of the tetra-SUMO2 were highly flexible. Individual SIMs of the RNF4-SIMs domains bind to SUMO2 in the groove between the β2-strand and the α1-helix parallel to the β2-strand. SIM2 and SIM3 bound to SUMO with a high affinity and together constituted the recognition module necessary for SUMO binding. SIM4 alone bound to SUMO with low affinity; however, its contribution to tetra-SUMO2 binding avidity is comparable with that of SIM3 when in the RNF4-SIMs domain. The SAXS data of the tetra-SUMO2-RNF4-SIMs domain complex indicate that it exists as an ordered structure. The HADDOCK model showed that the tandem RNF4-SIMs domain bound antiparallel to the tetra-SUMO2 chain orientation and wrapped around the SUMO protamers in a superhelical turn without imposing steric hindrance on either molecule.
NASA Astrophysics Data System (ADS)
Li, Ying; Ke, Chuan; Liu, Xiang; Gou, Fujun; Duan, Xuru; Zhao, Yong
2017-12-01
Liquid metal lithium cause severe corrosion on the surface of metal structure material that used in the blanket and first wall of fusion device. Fast and accurate compositional depth profile measurement for the boundary layer of the corroded specimen will reveal the clues for the understanding and evaluation of the liquid lithium corrosion process as well as the involved corrosion mechanism. In this work, the feasibility of laser-induced breakdown spectroscopy for the compositional depth profile analysis of type 316 stainless steel which was corroded by liquid lithium in certain conditions was demonstrated. High sensitivity of LIBS was revealed especially for the corrosion medium Li in addition to the matrix elements of Fe, Cr, Ni and Mn by the spectral analysis of the plasma emission. Compositional depth profile analysis for the concerned elements which related to corrosion was carried out on the surface of the corroded specimen. Based on the verified local thermodynamic equilibrium shot-by-shot along the depth profile, the matrix effect was evaluated as negligible by the extracted physical parameter of the plasmas generated by each laser pulse in the longitudinal depth profile. In addition, the emission line intensity ratios were introduced to further reduce the impact on the emission line intensity variations arise from the strong inhomogeneities on the corroded surface. Compositional depth profiles for the matrix elements of Fe, Cr, Ni, Mn and the corrosion medium Li were constructed with their measured relative emission line intensities. The distribution and correlations of the concerned elements in depth profile may indicate the clues to the complicated process of composition diffusion and mass transfer. The results obtained demonstrate the potentiality of LIBS as an effective technique to perform spectrochemical measurement in the research fields of liquid metal lithium corrosion.
Yorozu, M; Yanagida, T; Nakajyo, T; Okada, Y; Endo, A
2001-04-20
We measured the depth profile of hydrogen atoms in graphite by laser microprobing combined with resonant laser ablation. Deuterium-implanted graphite was employed for the measurements. The sample was ablated by a tunable laser with a wavelength corresponding to the resonant wavelength of 1S-2S of deuterium with two-photon excitation. The ablated deuterium was ionized by a 2 + 1 resonant ionization process. The ions were analyzed by a time-of-flight mass spectrometer. The deuterium ions were detected clearly with the resonant ablation. The detection limit was estimated to be less than 10(16) atoms/cm(3) in our experiments. We determined the depth profile by considering the etching profile and the etching rate. The depth profile agreed well with Monte Carlo simulations to within a precision of 23 mum for the center position and 4-mum precision for distributions for three different implantation depths.
Varley, J. B.; Conway, A. M.; Voss, L. F.; ...
2015-02-09
Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-xCL xmore » surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-xC1 X. This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.« less
Structural and optical properties of vanadium ion-implanted GaN
NASA Astrophysics Data System (ADS)
Macková, A.; Malinský, P.; Jagerová, A.; Sofer, Z.; Klímová, K.; Sedmidubský, D.; Mikulics, M.; Lorinčík, J.; Veselá, D.; Böttger, R.; Akhmadaliev, S.
2017-09-01
The field of advanced electronic and optical devices searches for a new generation of transistors and lasers. The practical development of these novel devices depends on the availability of materials with the appropriate magnetic and optical properties, which is strongly connected to the internal morphology and the structural properties of the prepared doped structures. In this contribution, we present the characterisation of V ion-doped GaN epitaxial layers. GaN layers, oriented along the (0 0 0 1) crystallographic direction, grown by low-pressure metal-organic vapour-phase epitaxy (MOVPE) on c-plane sapphire substrates were implanted with 400 keV V+ ions at fluences of 5 × 1015 and 5 × 1016 cm-2. Elemental depth profiling was accomplished by Rutherford Backscattering Spectrometry (RBS) and Secondary Ion Mass Spectrometry (SIMS) to obtain precise information about the dopant distribution. Structural investigations are needed to understand the influence of defect distribution on the crystal-matrix recovery and the desired structural and optical properties. The structural properties of the ion-implanted layers were characterised by RBS-channelling and Raman spectroscopy to get a comprehensive insight into the structural modification of implanted GaN and to study the influence of subsequent annealing on the crystalline matrix reconstruction. Photoluminescence measurement was carried out to check the optical properties of the prepared structures.
Nitrogen Fixation By Sulfate-Reducing Bacteria in Coastal and Deep-Sea Sediments
NASA Astrophysics Data System (ADS)
Bertics, V. J.; Löscher, C.; Salonen, I.; Schmitz-Streit, R.; Lavik, G.; Kuypers, M. M.; Treude, T.
2011-12-01
Sulfate-reducing bacteria (SRB) can greatly impact benthic nitrogen (N) cycling, by for instance inhibiting coupled denitrification-nitrification through the production of sulfide or by increasing the availability of fixed N in the sediment via dinitrogen (N2)-fixation. Here, we explored several coastal and deep-sea benthic habitats within the Atlantic Ocean and Baltic Sea, for the occurrence of N2-fixation mediated by SRB. A combination of different methods including microbial rate measurements of N2-fixation and sulfate reduction, geochemical analyses (porewater nutrient profiles, mass spectrometry), and molecular analyses (CARD-FISH, HISH-SIMS, "nested" PCR, and QPCR) were applied to quantify and identify the responsible processes and organisms, respectively. Furthermore, we looked deeper into the question of whether the observed nitrogenase activity was associated with the final incorporation of N into microbial biomass or whether the enzyme activity served another purpose. At the AGU Fall Meeting, we will present and compare data from numerous stations with different water depths, temperatures, and latitudes, as well as differences in key geochemical parameters, such as organic carbon content and oxygen availability. Current metabolic and molecular data indicate that N2-fixation is occurring in many of these benthic environments and that a large part of this activity may linked to SRB.
Irradiation-induced Ag-colloid formation in ion-exchanged soda-lime glass
NASA Astrophysics Data System (ADS)
Caccavale, F.; De Marchi, G.; Gonella, F.; Mazzoldi, P.; Meneghini, C.; Quaranta, A.; Arnold, G. W.; Battaglin, G.; Mattei, G.
1995-03-01
Ion-exchanged glass samples were obtained by immersing soda-lime slides in molten salt baths of molar concentration in the range 1-20% AgNO 3 in NaNO 3, at temperatures varying from 320 to 350°C, and processing times of the order of a few minutes. Irradiations of exchanged samples were subsequently performed by using H +m, He +, N + ions at different energies in order to obtain comparable projected ranges. The fluence was varied between 5 × 10 15 and 2 × 10 17 ions/cm 2. Most of the samples were treated at current densities lower than 2 μA/cm 2, in order to avoid heating effects. Some samples were irradiated with 4 keV electrons, corresponding to a range of 250 nm. The formation of nanoclusters of radii in the range 1-10 nm has been observed after irradiation, depending on the treatment conditions. The precipitation process is governed by the electronic energy deposition of incident particles. The most desirable results are obtained for helium implants. The process was characterized by the use of Secondary Ion Mass Spectrometry (SIMS) and nuclear techniques (Rutherford Backscattering (RBS), Nuclear Reactions (NRA)), in order to determine concentration-depth profiles and by optical absorption and Transmission Electron Microscopy (TEM) measurements for the silver nanoclusters detection and size evaluation.
Ultrafast syn-eruptive degassing and ascent trigger high-energy basic eruptions.
Giuffrida, Marisa; Viccaro, Marco; Ottolini, Luisa
2018-01-09
Lithium gradients in plagioclase are capable of recording extremely short-lived processes associated with gas loss from magmas prior to extrusion at the surface. We present SIMS profiles of the 7 Li/ 30 Si ion ratio in plagioclase crystals from products of the paroxysmal sequence that occurred in the period 2011-2013 at Mt. Etna (Italy) in an attempt to constrain the final ascent and degassing processes leading to these powerful eruptions involving basic magma. The observed Li concentrations reflect cycles of Li addition to the melt through gas flushing, and a syn-eruptive stage of magma degassing driven by decompression that finally produce significant Li depletion from the melt. Modeling the decreases in Li concentration in plagioclase by diffusion allowed determination of magma ascent timescales that are on the order of minutes or less. Knowledge of the storage depth beneath the volcano has led to the quantification of a mean magma ascent velocity of ~43 m/s for paroxysmal eruptions at Etna. The importance of these results relies on the application of methods, recently used exclusively for closed-system volcanoes producing violent eruptions, to open-conduit systems that have generally quiet eruptive periods of activity sometimes interrupted by sudden re-awakening and the production of anomalously energetic eruptions.
Plasma Immersion Ion Implantation for Interdigitated Back Passivated Contact (IBPC) Solar Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, David L.; Nemeth, William; LaSalvia, Vincenzo
2016-11-21
We present progress to develop low-cost interdigitated back contact solar cells with pc-Si/SiO2/c-Si passivated contacts formed by plasma immersion ion implantation (PIII). PIII is a lower-cost implantation technique than traditional beam-line implantation due to its simpler design, lower operating costs, and ability to run high doses (1E14-1E18 cm-2) at low ion energies (20 eV-10 keV). These benefits make PIII ideal for high throughput production of patterned passivated contacts, where high-dose, low-energy implantations are made into thin (20-200 nm) a-Si layers instead of into the wafer itself. For this work symmetric passivated contact test structures grown on n-Cz wafers with PH3more » PIII doping gave implied open circuit voltage (iVoc) values of 730 mV with Jo values of 2 fA/cm2. Samples doped with B2H6 gave iVoc values of 690 mV and Jo values of 24 fA/cm2, outperforming BF3 doping, which gave iVoc values in the 660-680 mV range. Samples were further characterized by photoluminescence and SIMS depth profiles. Initial IBPC cell results are presented.« less
A silicon technology for millimeter-wave monolithic circuits
NASA Astrophysics Data System (ADS)
Stabile, P. J.; Rosen, A.
1984-12-01
A silicon millimeter-wave integrated-circuit (SIMMWIC) technology that includes high-energy ion implantation and pulsed-laser annealing, secondary ion mass spectrometry (SIMS) profile diagnostics, and novel wafer thinning has been developed. This technology has been applied to a SIMMWIC single-pole single-throw (SPST) switch and to IMPATT and p-i-n diode fabrication schemes. Thus, the SIMMWIC technology is a proven base for monolithic millimeter-wave sources and control circuit applications.
NASA Astrophysics Data System (ADS)
Vaxelaire, N.; Kovacova, V.; Bernasconi, A.; Le Rhun, G.; Alvarez-Murga, M.; Vaughan, G. B. M.; Defay, E.; Gergaud, P.
2016-09-01
A direct quantification of a structural in-depth composition in the lead zirconate titanate Pb(Zr,Ti)O3 thin films of morphotropic composition has been conducted using the newly available X-ray nano-pencil beam (i.e., beam size of 100 nm × 1 μm) diffraction approach. We tested two samples with different Zr/Ti chemical gradients. Here, we demonstrate the presence of a significant microstructural gradient between the rhombohedral and tetragonal phases through PbZrxTi1-xO3 (PZT) films with a 100 nm in-depth resolution. The phase gradient extends over around 350 nm, and it is repeated through the PZT film three times, which corresponds to the number of thermal annealings. Moreover, this microstructural gradient is in agreement with the Zr/Ti chemical gradient observed by the secondary ion mass spectroscopy (SIMS). Indeed, the quantity of tetragonal phases rises in the Ti-rich zones as revealed by SIMS, and the quantity of rhombohedral phases rises in the Zr-rich zones. We also demonstrated a huge difference in the in-depth phase variation between the two tested samples. The gradient free sample still contains 4.7% of phase variation through the film and the amplified gradient contains 9.6% of phase variation through the film. Knowing that the gradient free sample shows better electric and piezoelectric coefficients, one can draw a correlation between the chemical composition, crystallographic homogeneity, and electro-mechanical properties of the film. The more close the film is to the morphotropic composition and the more it is crystallographically homogeneous, the higher the piezoelectric coefficients of the PZT are. Finally, the adequate knowledge of phase variation and its relation to the fabrication technique are crucial for the enhancement of the PZT electro-mechanical properties. Our methodology and findings open up new perspectives in establishing a relevant quantitative feedback to reach an ultimate electro-mechanical coupling in the sol-gel PZT thin films.
COACH: profile-profile alignment of protein families using hidden Markov models.
Edgar, Robert C; Sjölander, Kimmen
2004-05-22
Alignments of two multiple-sequence alignments, or statistical models of such alignments (profiles), have important applications in computational biology. The increased amount of information in a profile versus a single sequence can lead to more accurate alignments and more sensitive homolog detection in database searches. Several profile-profile alignment methods have been proposed and have been shown to improve sensitivity and alignment quality compared with sequence-sequence methods (such as BLAST) and profile-sequence methods (e.g. PSI-BLAST). Here we present a new approach to profile-profile alignment we call Comparison of Alignments by Constructing Hidden Markov Models (HMMs) (COACH). COACH aligns two multiple sequence alignments by constructing a profile HMM from one alignment and aligning the other to that HMM. We compare the alignment accuracy of COACH with two recently published methods: Yona and Levitt's prof_sim and Sadreyev and Grishin's COMPASS. On two sets of reference alignments selected from the FSSP database, we find that COACH is able, on average, to produce alignments giving the best coverage or the fewest errors, depending on the chosen parameter settings. COACH is freely available from www.drive5.com/lobster
Rachidi, Mohammed; Lopes, Carmela; Charron, Giselle; Delezoide, Anne-Lise; Paly, Evelyne; Bloch, Bernard; Delabar, Jean-Maurice
2005-08-01
Human SIM2 is the ortholog of Drosophila single-minded (sim), a master regulator of neurogenesis and transcriptional factor controlling midline cell fate determination. We previously localized SIM2 in a chromosome 21 critical region for Down syndrome (DS). Here, we studied SIM2 gene using a new approach to provide insights in understanding of its potential role in human development. For the first time, we showed SIM2 spatial and temporal expression pattern during human central nervous system (CNS) development, from embryonic to fetal stages. Additional investigations were performed using a new optic microscopy technology to compare signal intensity and cell density [M. Rachidi, C. Lopes, S. Gassanova, P.M. Sinet, M. Vekemans, T. Attie, A.L. Delezoide, J.M. Delabar, Regional and cellular specificity of the expression of TPRD, the tetratricopeptide Down syndrome gene, during human embryonic development, Mech. Dev. 93 (2000) 189--193]. In embryonic stages, SIM2 was identified predominantly in restricted regions of CNS, in ventral part of D1/D2 diencephalic neuroepithelium, along the neural tube and in a few cell subsets of dorsal root ganglia. In fetal stages, SIM2 showed differential expression in pyramidal and granular cell layers of hippocampal formation, in cortical cells and in cerebellar external granular and Purkinje cell layers. SIM2 expression in embryonic and fetal brain could suggest a potential role in human CNS development, in agreement with Drosophila and mouse Sim mutant phenotypes and with the conservation of the Sim function in CNS development from Drosophila to Human. SIM2 expression in human fetal brain regions, which correspond to key structures for cognitive processes, correlates well with the behavioral phenotypes of Drosophila Sim mutants and transgenic mice overexpressing Sim2. In addition, SIM2-expressing brain regions correspond to the altered structures in DS patients. All together, these findings suggest a potential role of SIM2 in CNS development and indicate that SIM2 overexpression could participate to the pathogenesis of mental retardation in Down syndrome patients.
Linear and Non-Linear Optical Imaging of Cancer Cells with Silicon Nanoparticles
Tolstik, Elen; Osminkina, Liubov A.; Akimov, Denis; Gongalsky, Maksim B.; Kudryavtsev, Andrew A.; Timoshenko, Victor Yu.; Heintzmann, Rainer; Sivakov, Vladimir; Popp, Jürgen
2016-01-01
New approaches for visualisation of silicon nanoparticles (SiNPs) in cancer cells are realised by means of the linear and nonlinear optics in vitro. Aqueous colloidal solutions of SiNPs with sizes of about 10–40 nm obtained by ultrasound grinding of silicon nanowires were introduced into breast cancer cells (MCF-7 cell line). Further, the time-varying nanoparticles enclosed in cell structures were visualised by high-resolution structured illumination microscopy (HR-SIM) and micro-Raman spectroscopy. Additionally, the nonlinear optical methods of two-photon excited fluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS) with infrared laser excitation were applied to study the localisation of SiNPs in cells. Advantages of the nonlinear methods, such as rapid imaging, which prevents cells from overheating and larger penetration depth compared to the single-photon excited HR-SIM, are discussed. The obtained results reveal new perspectives of the multimodal visualisation and precise detection of the uptake of biodegradable non-toxic SiNPs by cancer cells and they are discussed in view of future applications for the optical diagnostics of cancer tumours. PMID:27626408
NASA Astrophysics Data System (ADS)
Hinsdale, Taylor; Malik, Bilal; Olsovsky, Cory; Jo, Javier A.; Maitland, Kristen C.
2016-03-01
We present a volumetric imaging method for biological tissue that is free of mechanically scanning components. The optical sectioning in the system is obtained by structured illumination microscopy (SIM) with the depth of focus being varied by the use of an electronic tunable-focus lens (ETL). The performance of the axial scanning mechanism was evaluated and characterized in conjunction with SIM to ensure volumetric images could be recorded and reconstructed without significant losses in optical section thickness and lateral resolution over the full desired scan range. It was demonstrated that sub-cellular image resolutions were obtainable in both microsphere films and in ex vivo oral mucosa, spanning multiple cell layers, without significant losses in image quality. The mechanism proposed here has the ability to be integrated into any wide-field microscopy system to convert it into a three-dimensional imaging platform without the need for axial scanning of the sample or imaging optics. The ability to axially scan independent of mechanical movement also provides the opportunity for the development of endoscopic systems which can create volumetric images of tissue in vivo.
Dynamic Vertical Profiles of Peat Porewater Chemistry in a Northern Peatland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffiths, Natalie A.; Sebestyen, Stephen D.
We measured pH, cations, nutrients, and total organic carbon (TOC) over 3 years to examine weekly to monthly variability in porewater chemistry depth profiles (0–3.0 m) in an ombrotrophic bog in Minnesota, USA. We also compared temporal variation at one location to spatial variation in depth profiles at 16 locations across the bog. Most solutes exhibited large gradients with depth. pH increased by two units and calcium concentrations increased over 20 fold with depth, and may reflect peatland development from minerotrophic to ombrotrophic conditions. Ammonium concentrations increased almost 20 fold and TOC concentrations decreased by half with depth, and thesemore » patterns likely reflect mineralization of peat or decomposition of TOC. There was also considerable temporal variation in the porewater chemistry depth profiles. Ammonium, soluble reactive phosphorus, and potassium showed greater temporal variation in near-surface porewater, while pH, calcium, and TOC varied more at depth. This variation demonstrates that deep peat porewater chemistry is not static. Lastly, temporal variation in solute chemistry depth profiles was greater than spatial variation in several instances, especially in shallow porewaters. In conclusion, characterizing both temporal and spatial variability is necessary to ensure representative sampling in peatlands, especially when calculating solute pools and fluxes and parameterizing process-based models.« less
Dynamic Vertical Profiles of Peat Porewater Chemistry in a Northern Peatland
Griffiths, Natalie A.; Sebestyen, Stephen D.
2016-10-14
We measured pH, cations, nutrients, and total organic carbon (TOC) over 3 years to examine weekly to monthly variability in porewater chemistry depth profiles (0–3.0 m) in an ombrotrophic bog in Minnesota, USA. We also compared temporal variation at one location to spatial variation in depth profiles at 16 locations across the bog. Most solutes exhibited large gradients with depth. pH increased by two units and calcium concentrations increased over 20 fold with depth, and may reflect peatland development from minerotrophic to ombrotrophic conditions. Ammonium concentrations increased almost 20 fold and TOC concentrations decreased by half with depth, and thesemore » patterns likely reflect mineralization of peat or decomposition of TOC. There was also considerable temporal variation in the porewater chemistry depth profiles. Ammonium, soluble reactive phosphorus, and potassium showed greater temporal variation in near-surface porewater, while pH, calcium, and TOC varied more at depth. This variation demonstrates that deep peat porewater chemistry is not static. Lastly, temporal variation in solute chemistry depth profiles was greater than spatial variation in several instances, especially in shallow porewaters. In conclusion, characterizing both temporal and spatial variability is necessary to ensure representative sampling in peatlands, especially when calculating solute pools and fluxes and parameterizing process-based models.« less
Advances in Laser Microprobe (U-Th)/He Geochronology
NASA Astrophysics Data System (ADS)
van Soest, M. C.; Monteleone, B. D.; Boyce, J. W.; Hodges, K. V.
2008-12-01
The development of the laser microprobe (U-Th)/He dating method has the potential to overcome many of the limitations that affect conventional (U-Th)/He geochronology. Conventional single- or multi-crystal (U- Th)/He geochronology requires the use of pristine, inclusion-free, euhedral crystals. Furthermore, the ages that are obtained require corrections for the effects of zoning and alpha ejection based on an ensemble of assumptions before interpretation of their geological relevance is possible. With the utilization of microbeam techniques many of the limitations of conventional (U-Th)/He geochronology can either be eliminated by careful spot selection or accounted for by detailed depth profiling analyses of He, U and Th on the same crystal. Combined He, Th, and U depth profiling on the same crystal potentially even offers the ability to extract thermal histories from the analyzed grains. Boyce et al. (2006) first demonstrated the laser microprobe (U-Th)/He dating technique by successfully dating monazite crystals using UV laser ablation to liberate He and determined U and Th concentrations using a Cameca SX-Ultrachron microprobe. At Arizona State University, further development of the microprobe (U-Th)/He dating technique continues using an ArF Excimer laser connected to a GVI Helix Split Flight Tube noble gas mass spectrometer for He analysis and SIMS techniques for U and Th. The Durango apatite age standard has been successfully dated at 30.7 +/- 1.7 Ma (2SD). Work on dating zircons by laser ablation is currently underway, with initial results from Sri Lanka zircon at 437 +/- 14 Ma (2SD) confirmed by conventional (U-Th)/He analysis and in agreement with the published (U-Th)/He age of 443 +/- 9 Ma (2SD) for zircons from this region in Sri Lanka (Nasdala et al., 2004). The results presented here demonstrate the laser microprobe (U-Th)/He method as a powerful tool that allows application of (U- Th)/He dating to areas of research such as detrital apatite and zircon dating, where conventional (U-Th)/He geochronology has limited applicability. Boyce et al. (2006) GCA 70 (3031-3039), Nasdala et al. (2004) Am. Min. 89 (219-231)
Low energy implantation of boron with decaborane ions
NASA Astrophysics Data System (ADS)
Albano, Maria Angela
The goal of this dissertation was to determine the feasibility of a novel approach to forming ultra shallow p-type junctions (tens of nm) needed for future generations of Si MOS devices. In the new approach, B dopant atoms are implanted by cluster ions obtained by ionization of decaborane (B 10H14) vapor. An experimental ion implanter with an electron impact ion source and magnetic mass separation was built at the Ion Beam and Thin Film Research Laboratory at NJIT. Beams of B10Hx+ ions with currents of a few microamperes and energies of 1 to 12 keV were obtained and used for implantation experiments. Profiles of B and H atoms implanted in Si were measured by Secondary Ion Mass Spectroscopy (SIMS) before and after rapid thermal annealing (RTA). From the profiles, the junction depth of 57 nm (at 1018 cm-3 B concentration) was obtained with 12 keV decaborane ions followed by RTA. The dose of B atoms that can be implanted at low energy into Si is limited by sputtering as the ion beam sputters both the matrix and the implanted atoms. As the number of sputtered B atoms increases with the implanted dose and approaches the number of the implanted atoms, equilibrium of B in Si is established. This effect was investigated by comparison of the B dose calculated from the ion beam integration with B content in the sample measured by Nuclear Reaction Analysis (NRA). Maximum (equilibrium) doses of 1.35 x 1016 B cm -2 and 2.67 x 1016 B cm-2 were obtained at the beam energies of 5 and 12 keV, respectively. The problem of forming shallow p-type junctions in Si is related not only to implantation depth, but also to transient enhanced diffusion (TED). TED in Si implanted with B10Hx+ was measured on boron doping superlattice (B-DSL) marker layers. It was found that TED, following decaborane implantation, is the same as with monomer B+ ion implantation of equivalent energy and that it decreases with the decreasing ion energy. (Abstract shortened by UMI.)
Federle, T W; Ventullo, R M; White, D C
1990-12-01
The vertical distribution of microbial biomass, activity, community structure and the mineralization of xenobiotic chemicals was examined in two soil profiles in northern Wisconsin. One profile was impacted by infiltrating wastewater from a laundromat, while the other served as a control. An unconfined aquifer was present 14 meters below the surface at both sites. Biomass and community structure were determined by acridine orange direct counts and measuring concentrations of phospholipid-derived fatty acids (PLFA). Microbial activity was estimated by measuring fluorescein diacetate (FDA) hydrolysis, thymidine incorporation into DNA, and mixed amino acid (MAA) mineralization. Mineralization kinetics of linear alkylbenzene sulfonate (LAS) and linear alcohol ethoxylate (LAE) were determined at each depth. Except for MAA mineralization rates, measures of microbial biomass and activity exhibited similar patterns with depth. PLFA concentration and rates of FDA hydrolysis and thymidine incorporation decreased 10-100 fold below 3 m and then exhibited little variation with depth. Fungal fatty acid markers were found at all depths and represented from 1 to 15% of the total PLFAs. The relative proportion of tuberculostearic acid (TBS), an actinomycete marker, declined with depth and was not detected in the saturated zone. The profile impacted by wastewater exhibited higher levels of PLFA but a lower proportion of TBS than the control profile. This profile also exhibited faster rates of FDA hydrolysis and amino acid mineralization at most depths. LAS was mineralized in the upper 2 m of the vadose zone and in the saturated zone of both profiles. Little or no LAS biodegradation occurred at depths between 2 and 14 m. LAE was mineralized at all depths in both profiles, and the mineralization rate exhibited a similar pattern with depth as biomass and activity measurements. In general, biomass and biodegradative activities were much lower in groundwater than in soil samples obtained from the same depth.
SIM Lite Astrometric Observatory progress report
NASA Astrophysics Data System (ADS)
Marr, James C., IV; Shao, Michael; Goullioud, Renaud
2010-07-01
The SIM Lite Astrometric Observatory (aka SIM Lite), a micro-arcsecond astrometry space mission, has been developed in response to NASA's indefinite deferral of the SIM PlanetQuest mission. The SIM Lite mission, while significantly more affordable than the SIM PlanetQuest mission concept, still addresses the full breadth of SIM science envisioned by two previous National Research Council (NRC) Astrophysics Decadal Surveys at the most stringent "Goal" level of astrometric measurement performance envisioned in those surveys. Over the past two years, the project has completed the conceptual design of the SIM Lite mission using only the completed SIM technology; published a 250 page book describing the science and mission design (available at the SIM website: http://sim.jpl.nasa.gov); been subject to an independent cost and technical readiness assessment by the Aerospace Corporation; and submitted a number of information responses to the NRC Astro2010 Decadal Survey. The project also conducted an exoplanet-finding capability double blind study that clearly demonstrated the ability of the mission to survey 60 to 100 nearby sun-like dwarf stars for terrestrial, habitable zone planets in complex planetary systems. Additionally, the project has continued Engineering Risk Reduction activities by building brassboard (form, fit & function to flight) version of key instrument elements and subjecting them to flight qualification environmental and performance testing. This paper summarizes the progress over the last two years and the current state of the SIM Lite project.
SimPackJ/S: a web-oriented toolkit for discrete event simulation
NASA Astrophysics Data System (ADS)
Park, Minho; Fishwick, Paul A.
2002-07-01
SimPackJ/S is the JavaScript and Java version of SimPack, which means SimPackJ/S is a collection of JavaScript and Java libraries and executable programs for computer simulations. The main purpose of creating SimPackJ/S is that we allow existing SimPack users to expand simulation areas and provide future users with a freeware simulation toolkit to simulate and model a system in web environments. One of the goals for this paper is to introduce SimPackJ/S. The other goal is to propose translation rules for converting C to JavaScript and Java. Most parts demonstrate the translation rules with examples. In addition, we discuss a 3D dynamic system model and overview an approach to 3D dynamic systems using SimPackJ/S. We explain an interface between SimPackJ/S and the 3D language--Virtual Reality Modeling Language (VRML). This paper documents how to translate C to JavaScript and Java and how to utilize SimPackJ/S within a 3D web environment.
Neutron Depth Profiling: Overview and Description of NIST Facilities
Downing, R. G.; Lamaze, G. P.; Langland, J. K.; Hwang, S. T.
1993-01-01
The Cold Neutron Depth Profiling (CNDP) instrument at the NIST Cold Neutron Research Facility (CNRF) is now operational. The neutron beam originates from a 16 L D2O ice cold source and passes through a filter of 135 mm of single crystal sapphire. The neutron energy spectrum may be described by a 65 K Maxwellian distribution. The sample chamber configuration allows for remote controlled scanning of 150 × 150 mm sample areas including the varying of both sample and detector angle. The improved sensitivity over the current thermal depth profiling instrument has permitted the first nondestructive measurements of 17O profiles. This paper describes the CNDP instrument, illustrates the neutron depth profiling (NDP) technique with examples, and gives a separate bibliography of NDP publications. PMID:28053461
Effect of Simvastatin Prodrug on Experimental Periodontitis.
Bradley, Aaron D; Zhang, Yijia; Jia, Zhenshan; Zhao, Gang; Wang, Xiaobei; Pranke, Laura; Schmid, Marian J; Wang, Dong; Reinhardt, Richard A
2016-05-01
Local application of statins has shown potential in preventing and regenerating bone loss associated with experimental periodontitis. This study evaluates the effect of a novel simvastatin (SIM) prodrug (capable of delivering high doses to periodontitis inflammatory lesion and cells) on experimental periodontitis bone loss and inflammation. Forty mature female Sprague Dawley rats were subjected to ligature-induced experimental periodontitis between maxillary first and second molars (M1-M2). Equal groups were treated with three weekly doses of: 1) prodrug carrier alone (mPEG); 2) 0.5 mg SIM dose equivalent in carrier (SIM/SIM-mPEG); 3) 1.0 mg SIM/SIM-mPEG; 4) 1.5 mg SIM/SIM-mPEG; or 5) ligature alone. Contralateral molars served as unmanipulated controls. Four weeks after initiation of periodontitis, animals were euthanized, the M1-M2 interproximal was evaluated with microcomputed tomography and histology, and data were analyzed with one-way analysis of variance. Ligature alone caused a mean bone loss of 1.01 ± 0.06 mm from the cemento-enamel junction, whereas all doses of SIM/SIM-mPEG reduced bone loss, especially 1.5 mg SIM/SIM-mPEG (0.68 ± 0.05 mm, P <0.001), which was not statistically different from contralateral control (0.47 ± 0.06 mm). A dose of 1.5 mg SIM/SIM-mPEG also reduced percentage of neutrophils compared with carrier alone (2.0% ± 1.0% versus 5.7% ± 1.1%; P <0.05), and increased amount of uninflamed connective tissue in the M1-M2 interproximal area (65.2% ± 3.3% versus 46.3% ± 3.3%; P <0.001). The mPEG carrier alone did not have bone-sparing or anti-inflammatory properties. Multiple local 1.5-mg doses of a macromolecular SIM prodrug decreases amount of experimental periodontitis bone loss and inflammation in rats.
Automated Discovery of Simulation Between Programs
2014-10-18
relation. These relations enable the refinement-step of SimAbs. We have implemented SimAbs using UFO framework and Z3 SMT-solver and applied it to...step of SimAbs. We implemented SimAbs and AE-VAL on the top of the UFO framework [1, 15] and an SMT-solver Z3 [8], respectively. We have evaluated SimAbs...ut 6 Evaluation We have implemented SimAbs in the UFO framework, and evaluated it on the Software Verification Competition (SVCOMP’14) benchmarks and
Kublaoui, Bassil M; Holder, J Lloyd; Gemelli, Terry; Zinn, Andrew R
2006-10-01
Single-minded 1 (SIM1) is one of only six genes implicated in human monogenic obesity. Haploinsufficiency of this hypothalamic transcription factor is associated with hyperphagic obesity and increased linear growth in both humans and mice. Additionally, Sim1 heterozygous mice show enhanced hyperphagia and obesity in response to a high-fat diet. Thus the phenotype of Sim1 haploinsufficiency is similar to that of agouti yellow (Ay), and melanocortin 4 receptor (Mc4r) knockout mice, both of which are defective in hypothalamic melanocortin signaling. Sim1 and Mc4r are both expressed in the paraventricular nucleus (PVN). Here we report that Sim1 heterozygous mice, which have normal energy expenditure, are hyperphagic despite having elevated hypothalamic proopiomelanocortin (Pomc) expression. In response to the melanocortin agonist melanotan-2 (MTII) they exhibit a blunted suppression of feeding yet increase their energy expenditure normally. They also fail to activate PVN neurons in response to the drug at a dose that induces robust c-Fos expression in a subset of Sim1 PVN neurons in wild-type mice. The resistance to melanocortin signaling in Sim1 heterozygotes is not due to a reduced number of Sim1 neurons in the PVN. Hypothalamic Sim1 gene expression is induced by leptin and MTII treatment. Our results demonstrate that Sim1 heterozygotes are resistant to hypothalamic melanocortin signaling and suggest that Sim1-expressing PVN neurons regulate feeding, but not energy expenditure, in response to melanocortin signaling.
Le, Tung B K; Stevenson, Clare E M; Fiedler, Hans-Peter; Maxwell, Anthony; Lawson, David M; Buttner, Mark J
2011-04-22
Simocyclinone D8 (SD8), a potent DNA gyrase inhibitor made by Streptomyces antibioticus, is exported from the producing organism by the SimX efflux pump. The expression of simX is under the control of SimR, a member of the TetR family of transcriptional regulators. SimR represses simX transcription by binding to operators in the intergenic region between simR and simX. Previously, we have shown that the mature antibiotic SD8 or its biosynthetic intermediate, simocyclinone C4, can dissociate SimR from its operators, leading to derepression of simX and export of SD8 from the cell. This provides a mechanism that couples the biosynthesis of the antibiotic to its export. Here, we report the crystal structures of SimR alone and in complex with either SD8 or simocyclinone C4. The ligand-binding pocket is unusual compared to those of other characterized TetR-family transcriptional regulators: the structures show an extensive ligand-binding pocket spanning both monomers in the functional dimeric unit, with the aminocoumarin moiety of SD8 buried in the protein core, while the angucyclic polyketide moiety is partially exposed to bulk solvent. Through comparisons of the structures, we postulate a derepression mechanism for SimR that invokes rigid-body motions of the subunits relative to one another, coupled with a putative locking mechanism to restrict further conformational change. Copyright © 2011 Elsevier Ltd. All rights reserved.
Profilometric characterization of DOEs with continuous microrelief
NASA Astrophysics Data System (ADS)
Korolkov, V. P.; Ostapenko, S. V.; Shimansky, R. V.
2008-09-01
Methodology of local characterization of continuous-relief diffractive optical elements has been discussed. The local profile depth can be evaluated using "approximated depth" defined without taking a profile near diffractive zone boundaries into account. Several methods to estimate the approximated depth have been offered.
Elsharkawy, Aisha; Eletreby, Rasha; Fouad, Rabab; Soliman, Zeinab; Abdallah, Mohamed; Negm, Mohamed; Mohey, Mohammad; Esmat, Gamal
2017-08-01
Huge efforts have been made to control chronic HCV in Egypt with introduction of Direct-Acting Antivirals (DAAs). Current study aims at evaluating effect of various DAA regimens on liver biochemical profile and haematological indices during treatment. 272 patients with chronic HCV genotype 4 treated by different DAA regimens (SOF/RBV, SOF/DAC ± RBV, SOF/SIM) for a duration of 12 or 24 weeks in Kasr Alainy Viral Hepatitis Center, Cairo University were followed up for serum bilirubin (BIL), albumin (ALB), alanine transaminase (ALT), aspartate aminotransferase (AST), prothrombin concentration, international normalized ratio (INR), and CBC at baseline, week-4 and end of treatment. Mean age was 54 years. Males comprised 64.7%, 72.4% were treatment-naïve, 39% were cirrhotic. Overall SVR12 rate was (93.4%). With all regimens, ALT and AST declined after treatment. In cirrhotics, there was a rise in BIL and INR; with no change in ALB and a decrease in White blood cells. Drop in Hemoglobin and platelets in cirrhotic patients were noted with SOF/RBV, while SOF/SIM showed rise in BIL. DAAs are safe and effective in genotype 4 chronic HCV patients. It improves liver necro-inflammatory markers in cirrhotics and non-cirrhotics. Cirrhotic patients require careful observation being more vulnerable for treatment related complications.
Dowlatshahi Pour, Masoumeh; Jennische, Eva; Lange, Stefan; Ewing, Andrew G; Malmberg, Per
2016-06-11
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used for lipid profiling of intestine tissue sections from rats fed specially processed cereals and rats fed ordinary feed as a control. This cereal is known to increase the activity of antisecretory factor in plasma and the exact mechanism for the activation process at the cellular level is unclear. ToF-SIMS has been used to track food induced changes in lipid content in intestinal tissue sections to gain insight into the possible mechanisms involved. Data from 20 intestine sections belonging to four different rats from each group of control and specially processed cereals-fed rats were obtained using the stage scan macroraster with a lateral resolution of 5 μm. Data were subsequently subjected to orthogonal partial least squares discriminant analysis. The data clearly show that changes of certain lipids are induced by the specially processed cereal feed. Scores plots show a well-defined separation between the two groups. The corresponding loading plots reveal that the groups separate mainly due to changes of vitamin E, phosphocholine, and phosphosphingolipid fragments, and that for the c18:2 fatty acid. The observed changes in lipids might give insight into the working mechanisms of antisecretory factor in the body, and this has been successfully used to understand the working mechanism of specially processed cereal-induced antisecretory factor activation in intestine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belz, J.; Cao, Z.; Huentemeyer, P.
Measurements are reported on the fluorescence of air as a function of depth in electromagnetic showers initiated by bunches of 28.5 GeV electrons. The light yield is compared with the expected and observed depth profiles of ionization in the showers. It validates the use of atmospheric fluorescence profiles in measuring ultra high energy cosmic rays.
SimSchool: An Opportunity for Using Serious Gaming for Training Teachers in Rural Areas
ERIC Educational Resources Information Center
Tyler-Wood, Tandra; Estes, Mary; Christensen, Rhonda; Knezek, Gerald; Gibson, David
2015-01-01
This article examines the use of simSchool as a training tool for educators working with students with special needs in rural districts. SimSchool is a game that emulates a classroom utilizing a virtual environment. The theory supporting simSchool is explored and current research associated with simSchool is reviewed. The issues surrounding…
Profiling defect depth in composite materials using thermal imaging NDE
NASA Astrophysics Data System (ADS)
Obeidat, Omar; Yu, Qiuye; Han, Xiaoyan
2018-04-01
Sonic Infrared (IR) NDE, is a relatively new NDE technology; it has been demonstrated as a reliable and sensitive method to detect defects. SIR uses ultrasonic excitation with IR imaging to detect defects and flaws in the structures being inspected. An IR camera captures infrared radiation from the target for a period of time covering the ultrasound pulse. This period of time may be much longer than the pulse depending on the defect depth and the thermal properties of the materials. With the increasing deployment of composites in modern aerospace and automobile structures, fast, wide-area and reliable NDE methods are necessary. Impact damage is one of the major concerns in modern composites. Damage can occur at a certain depth without any visual indication on the surface. Defect depth information can influence maintenance decisions. Depth profiling relies on the time delays in the captured image sequence. We'll present our work on the defect depth profiling by using the temporal information of IR images. An analytical model is introduced to describe heat diffusion from subsurface defects in composite materials. Depth profiling using peak time is introduced as well.
Ablation of Sim1 Neurons Causes Obesity through Hyperphagia and Reduced Energy Expenditure
Xi, Dong; Gandhi, Nilay; Lai, Meizan; Kublaoui, Bassil M.
2012-01-01
Single-minded 1 (Sim1) is a transcription factor necessary for development of the paraventricular nucleus of the hypothalamus (PVH). This nucleus is a critical regulator of appetite, energy expenditure and body weight. Previously we showed that Sim1+/− mice and conditional postnatal Sim1−/− mice exhibit hyperphagia, obesity, increased linear growth and susceptibility to diet-induced obesity, but no decrease in energy expenditure. Bilateral ablation of the PVH causes obesity due to hyperphagia and reduced energy expenditure. It remains unknown whether Sim1 neurons regulate energy expenditure. In this study, Sim1cre mice were bred to homozygous inducible diphtheria toxin receptor (iDTR) mice to generate mice expressing the simian DTR in Sim1 cells. In these mice, Sim1 neuron ablation was performed by intracerebroventricular (ICV) injection of diphtheria toxin. Compared to controls, mice with Sim1 neuron ablation became obese (with increased fat mass) on a chow diet due to increased food intake and reduced energy expenditure. In post-injection mice, we observed a strong inverse correlation between the degree of obesity and hypothalamic Sim1 expression. The reduction in baseline energy expenditure observed in these mice was accompanied by a reduction in activity. This reduction in activity did not fully account for the reduced energy expenditure as these mice exhibited decreased resting energy expenditure, decreased body temperature, decreased brown adipose tissue temperature, and decreased UCP1 expression suggesting an impairment of thermogenesis. In injected mice, hypothalamic gene expression of Sim1, oxytocin (OXT) and thyrotropin releasing hormone (TRH) was reduced by about 50%. These results demonstrate that Sim1 neurons in adult mice regulate both food intake and energy expenditure. Based on the body of work in the field, feeding regulation by Sim1 neurons likely occurs in both the PVH and medial amygdala, in contrast to energy expenditure regulation by Sim1 neurons, which likely is localized to the PVH. PMID:22558467
Ablation of Sim1 neurons causes obesity through hyperphagia and reduced energy expenditure.
Xi, Dong; Gandhi, Nilay; Lai, Meizan; Kublaoui, Bassil M
2012-01-01
Single-minded 1 (Sim1) is a transcription factor necessary for development of the paraventricular nucleus of the hypothalamus (PVH). This nucleus is a critical regulator of appetite, energy expenditure and body weight. Previously we showed that Sim1(+/-) mice and conditional postnatal Sim1(-/-) mice exhibit hyperphagia, obesity, increased linear growth and susceptibility to diet-induced obesity, but no decrease in energy expenditure. Bilateral ablation of the PVH causes obesity due to hyperphagia and reduced energy expenditure. It remains unknown whether Sim1 neurons regulate energy expenditure. In this study, Sim1cre mice were bred to homozygous inducible diphtheria toxin receptor (iDTR) mice to generate mice expressing the simian DTR in Sim1 cells. In these mice, Sim1 neuron ablation was performed by intracerebroventricular (ICV) injection of diphtheria toxin. Compared to controls, mice with Sim1 neuron ablation became obese (with increased fat mass) on a chow diet due to increased food intake and reduced energy expenditure. In post-injection mice, we observed a strong inverse correlation between the degree of obesity and hypothalamic Sim1 expression. The reduction in baseline energy expenditure observed in these mice was accompanied by a reduction in activity. This reduction in activity did not fully account for the reduced energy expenditure as these mice exhibited decreased resting energy expenditure, decreased body temperature, decreased brown adipose tissue temperature, and decreased UCP1 expression suggesting an impairment of thermogenesis. In injected mice, hypothalamic gene expression of Sim1, oxytocin (OXT) and thyrotropin releasing hormone (TRH) was reduced by about 50%. These results demonstrate that Sim1 neurons in adult mice regulate both food intake and energy expenditure. Based on the body of work in the field, feeding regulation by Sim1 neurons likely occurs in both the PVH and medial amygdala, in contrast to energy expenditure regulation by Sim1 neurons, which likely is localized to the PVH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Surendra; Fitzsimmons, M. R.; Lookman, T.
We measured the chemical and magnetic depth profiles of a single crystalline film grown on a NdGaO 3 substrate using x-ray reflectometry, electron microscopy, electron energy-loss spectroscopy and polarized neutron reflectometry. Our data indicate that the film exhibits coexistence of different magnetic phases as a function of depth. The magnetic depth profile is correlated with a variation of chemical composition with depth. The thermal hysteresis of ferromagnetic order in the film suggests a first order ferromagnetic transition at low temperatures
Maine Geological Survey Borehole Temperature Profiles
Marvinney, Robert
2013-11-06
This dataset includes temperature profiles from 30 boreholes throughout Maine that were selected for their depth, location, and lithologies encountered. Depths range from about 300 feet to 2,200 feet. Most of the boreholes selected for measurement were completed in granite because this lithology can be assumed to be nearly homogeneous over the depth of the borehole. Boreholes were also selected to address gaps in existing geothermal datasets. Temperature profiles were collected in October and November, 2012.
The use of secondary ion mass spectrometry in forensic analyses of ultra-small samples
NASA Astrophysics Data System (ADS)
Cliff, John
2010-05-01
It is becoming increasingly important in forensic science to perform chemical and isotopic analyses on very small sample sizes. Moreover, in some instances the signature of interest may be incorporated in a vast background making analyses impossible by bulk methods. Recent advances in instrumentation make secondary ion mass spectrometry (SIMS) a powerful tool to apply to these problems. As an introduction, we present three types of forensic analyses in which SIMS may be useful. The causal organism of anthrax (Bacillus anthracis) chelates Ca and other metals during spore formation. Thus, the spores contain a trace element signature related to the growth medium that produced the organisms. Although other techniques have been shown to be useful in analyzing these signatures, the sample size requirements are generally relatively large. We have shown that time of flight SIMS (TOF-SIMS) combined with multivariate analysis, can clearly separate Bacillus sp. cultures prepared in different growth media using analytical spot sizes containing approximately one nanogram of spores. An important emerging field in forensic analysis is that of provenance of fecal pollution. The strategy of choice for these analyses-developing host-specific nucleic acid probes-has met with considerable difficulty due to lack of specificity of the probes. One potentially fruitful strategy is to combine in situ nucleic acid probing with high precision isotopic analyses. Bulk analyses of human and bovine fecal bacteria, for example, indicate a relative difference in d13C content of about 4 per mil. We have shown that sample sizes of several nanograms can be analyzed with the IMS 1280 with precisions capable of separating two per mil differences in d13C. The NanoSIMS 50 is capable of much better spatial resolution than the IMS 1280, albeit at a cost of analytical precision. Nevertheless we have documented precision capable of separating five per mil differences in d13C using analytical spots containing less than 300 picograms of bacteria. Perhaps the most successful application of SIMS for forensic purposes to date is in the field of nuclear forensics. An example that has been used by laboratories associated with the International Atomic Energy Agency is the examination of environmental samples for enriched uranium particles indicative of clandestine weapons production activities.. The analytical challenge in these types of measurements is to search complex environmental matrices for U-bearing particles which must then be analyzed for 234U, 235U, and 236U content with high precision and accuracy. Older-generation SIMS instruments were hampered by small geometries that made resolution of significant interferences problematic. In addition, automated particle search software was proprietary and difficult to obtain. With the development of new search software, the IMS 1280 is capable of searching a sample in a matter of hours, flagging U-bearing particles for later analyses, and providing a rough 235U content. Particles of interest can be revisited for high precision analyses, and all U-isotopes can be measured simultaneously in multicollector mode, dramatically improving analysis time and internal precision. Further, the large geometry of the instrument allows complete resolution of isobaric interferences that have traditionally limited SIMS analyses of difficult samples. Examples of analyses of micron-sized standard particles indicate that estimates of 235U enrichment can be obtained with an external relative precision of 0.1% and 234U and 236U contents can be obtained with a relative precision of less than 1%. Analyses of 'real' samples show a dramatic improvement in the data quality obtained compared with small-geometry SIMS instruments making SIMS the method of choice for these high-profile samples when accurate, precise, and rapid results are required.
NASA Astrophysics Data System (ADS)
Zhang, Zhan; Wendt, Scott; Cosentino, Nicholas; Bond, Leonard J.
2018-04-01
Limited by photon energy, and penetration capability, traditional X-ray diffraction (XRD) strain measurements are only capable of achieving a few microns depth due to the use of copper (Cu Kα1) or molybdenum (Mo Kα1) characteristic radiation. For deeper strain depth profiling, destructive methods are commonly necessary to access layers of interest by removing material. To investigate deeper depth profiles nondestructively, a laboratory bench-top high-energy X-ray diffraction (HEXRD) system was previously developed. This HEXRD method uses an industrial 320 kVp X-Ray tube and the Kα1 characteristic peak of tungsten, to produces a higher intensity X-ray beam which enables depth profiling measurement of lattice strain. An aluminum sample was investigated with deformation/load provided using a bending rig. It was shown that the HEXRD method is capable of strain depth profiling to 2.5 mm. The method was validated using an aluminum sample where both the HEXRD method and the traditional X-ray diffraction method gave data compared with that obtained using destructive etching layer removal, performed by a commercial provider. The results demonstrate comparable accuracy up to 0.8 mm depth. Nevertheless, higher attenuation capabilities in heavier metals limit the applications in other materials. Simulations predict that HEXRD works for steel and nickel in material up to 200 µm, but experiment results indicate that the HEXRD strain profile is not practical for steel and nickel material, and the measured diffraction signals are undetectable when compared to the noise.
Brigl, B; Ammenwerth, E; Dujat, C; Gräber, S; Grosse, A; Häber, A; Jostes, C; Winter, A
2005-01-01
Systematic information management in hospitals demands for a strategic information management plan (SIM plan). As preparing a SIM plan is a considerable challenge we provide a practical guideline that is directly applicable when a SIM plan is going to be prepared. The guideline recommends a detailed structure of a SIM plan and gives advice about its content and the preparation process. It may be used as template, which can be adapted to the individual demands of any hospital. The guideline was used in several hospitals preparing a SIM plan. Experiences showed that the SIM plans could be prepared very efficiently and timely using the guideline, that the proposed SIM plan structure suited well, that the guideline offers enough flexibility to meet the requirements of the individual hospitals and that the specific recommendations of the guideline were very helpful. Nevertheless, we must strive for a more comprehensive theory of strategic information management planning which -- in the sense of enterprise architecture planning -- represents the intrinsic correlations of the different parts of a SIM plan to a greater extent.
Upper mantle electrical conductivity for seven subcontinental regions of the Earth
Campbell, W.H.; Schiffmacher, E.R.
1988-01-01
Spherical harmonic analysis coefficients of the external and internal parts of the quiet-day geomagnetic field variations (Sq) separated for the 7 continental regions of the observatories have been used to determine conductivity profiles to depths of about 600 km by the Schmucker equivalent substitute conductor method. The profiles give evidence of increases in conductivity between about 150 and 350 km depth, then a general increase in conductivity thereafter. For South America we found a high conductivity at shallow depths. The European profile showed a highly conducting layer near 125 km. At the greater depths, Europe, Australia and South America had the lowest values of conductivity. North America and east Asia had intermediate values whereas the African and central Asian profiles both showed the conductivities rising rapidly beyond 450 km depth. The regional differences indicate that there may be considerable lateral heterogeneity of electrical conductivity in the Earth's upper mantle. -Authors
Mechanistic study of the rubber-brass adhesion interphase
NASA Astrophysics Data System (ADS)
Ashirgade, Akshay
Brass-plated steel tire cords form an essential strengthening component of a radial automobile tire. Adhesion between rubber compound and brass-plated steel tire cord is crucial in governing the overall performance of tires. The rubber-brass interfacial adhesion is influenced by the chemical composition and thickness of the interfacial layer. It has been shown that the interfacial layer consists mainly of sulfides and oxides of copper and zinc. This thesis discusses the effect of changes in the chemical composition and the structure of the interfacial layers due to addition of adhesion promoter resins. Grazing incidence X-Ray Diffraction (GIXRD) experiments were run on sulfidized polished brass coupons previously bonded to six experimental rubber compounds. It was confirmed that heat and humidity conditions lead to physical and chemical changes of the rubber-steel tire cord interfacial layer, closely related to the degree of rubber-brass adhesion. Morphological transformation of the interfacial layer led to loss of adhesion after aging. The adhesion promoter resins inhibit unfavorable morphological changes in the interfacial layer thus stabilizing it during aging and prolonging failure. Tire cord adhesion tests illustrated that the one-component resins improved adhesion after aging using a rubber compound with lower cobalt loading. Based on the acquired diffraction profiles, these resins were also found to impede crystallization of the sulfide layer after aging leading to improved adhesion. Secondary Ion Mass Spectrometry (SIMS) depth profiles, SEM micrographs and AFM images strongly corroborated the findings from GIXRD. FTIR was utilized in a novel way to understand the degradation mechanism due to aging. A model for rubber and interfacial layer degradation is proposed to illustrate the effect of aging and the one-component resins. This interfacial analysis adds valuable new information to our understanding of the complex nature of the rubber-brass bonding mechanism.
NASA Astrophysics Data System (ADS)
Díaz, D.; Maksymowicz, A.; Vargas, G.; Vera, E.; Contreras-Reyes, E.; Rebolledo, S.
2014-01-01
The crustal-scale west-vergent San Ramón thrust fault system at the foot of the main Andean Cordillera in central Chile is a geologically active structure with Quaternary manifestations of complex surface rupture along fault segments in the eastern border of Santiago city. From the comparison of geophysical and geological observations, we assessed the subsurface structure pattern affecting sedimentary cover and rock-substratum topography across fault scarps, which is critic for evaluating structural modeling and associated seismic hazard along this kind of faults. We performed seismic profiles with an average length of 250 m, using an array of twenty-four geophones (GEODE), and 25 shots per profile, supporting high-resolution seismic tomography for interpreting impedance changes associated to deformed sedimentary cover. The recorded traveltime refractions and reflections were jointly inverted by using a 2-D tomographic approach, which resulted in variations across the scarp axis in both velocities and reflections interpreted as the sedimentary cover-rock substratum topography. Seismic anisotropy observed from tomographic profiles is consistent with sediment deformation triggered by west-vergent thrust tectonics along the fault. Electrical soundings crossing two fault scarps supported subsurface resistivity tomographic profiles, which revealed systematic differences between lower resistivity values in the hanging wall with respect to the footwall of the geological structure, clearly limited by well-defined east-dipping resistivity boundaries. The latter can be interpreted in terms of structurally driven fluid content-change between the hanging wall and the footwall of a permeability boundary associated with the San Ramón fault. The overall results are consistent with a west-vergent thrust structure dipping ∼55° E at subsurface levels in piedmont sediments, with local complexities being probably associated to fault surface rupture propagation, fault-splay and fault segment transfer zones.
NASA Astrophysics Data System (ADS)
Reda, Ahmed A.; Schnelle-Kreis, J.; Orasche, J.; Abbaszade, G.; Lintelmann, J.; Arteaga-Salas, J. M.; Stengel, B.; Rabe, R.; Harndorf, H.; Sippula, O.; Streibel, T.; Zimmermann, R.
2014-09-01
Gas phase emission samples of carbonyl compounds (CCs) were collected from a research ship diesel engine at Rostock University, Germany. The ship engine was operated using two different types of fuels, heavy fuel oil (HFO) and diesel fuel (DF). Sampling of CCs was performed from diluted exhaust using cartridges and impingers. Both sampling methods involved the derivatization of CCs with 2,4-Dinitrophenylhydrazine (DNPH). The CCs-hydrazone derivatives were analyzed by two analytical techniques: High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD) and Gas Chromatography-Selective Ion Monitoring-Mass Spectrometry (GC-SIM-MS). Analysis of DNPH cartridges by GC-SIM-MS method has resulted in the identification of 19 CCs in both fuel operations. These CCs include ten aliphatic aldehydes (formaldehyde, acetaldehyde, propanal, isobutanal, butanal, isopentanal, pentanal, hexanal, octanal, nonanal), three unsaturated aldehydes (acrolein, methacrolein, crotonaldehyde), three aromatic aldehyde (benzaldehyde, p-tolualdehyde, m,o-molualdehyde), two ketones (acetone, butanone) and one heterocyclic aldehyde (furfural). In general, all CCs under investigation were detected with higher emission factors in HFO than DF. The total carbonyl emission factor was determined and found to be 6050 and 2300 μg MJ-1 for the operation with HFO and DF respectively. Formaldehyde and acetaldehyde were found to be the dominant carbonyls in the gas phase of ship engine emission. Formaldehyde emissions factor varied from 3500 μg MJ-1 in HFO operation to 1540 μg MJ-1 in DF operation, which is 4-30 times higher than those of other carbonyls. Emission profile contribution of CCs showed also a different pattern between HFO and DF operation. The contribution of formaldehyde was found to be 58% of the emission profile of HFO and about 67% of the emission profile of DF. Acetaldehyde showed opposite behavior with higher contribution of 16% in HFO compared to 11% for DF. Heavier carbonyls (more than two carbon atoms) showed also more contribution in the emission profile of the HFO fuel (26%) than in DF (22%).
The Analytical Limits of Modeling Short Diffusion Timescales
NASA Astrophysics Data System (ADS)
Bradshaw, R. W.; Kent, A. J.
2016-12-01
Chemical and isotopic zoning in minerals is widely used to constrain the timescales of magmatic processes such as magma mixing and crystal residence, etc. via diffusion modeling. Forward modeling of diffusion relies on fitting diffusion profiles to measured compositional gradients. However, an individual measurement is essentially an average composition for a segment of the gradient defined by the spatial resolution of the analysis. Thus there is the potential for the analytical spatial resolution to limit the timescales that can be determined for an element of given diffusivity, particularly where the scale of the gradient approaches that of the measurement. Here we use a probabilistic modeling approach to investigate the effect of analytical spatial resolution on estimated timescales from diffusion modeling. Our method investigates how accurately the age of a synthetic diffusion profile can be obtained by modeling an "unknown" profile derived from discrete sampling of the synthetic compositional gradient at a given spatial resolution. We also include the effects of analytical uncertainty and the position of measurements relative to the diffusion gradient. We apply this method to the spatial resolutions of common microanalytical techniques (LA-ICP-MS, SIMS, EMP, NanoSIMS). Our results confirm that for a given diffusivity, higher spatial resolution gives access to shorter timescales, and that each analytical spacing has a minimum timescale, below which it overestimates the timescale. For example, for Ba diffusion in plagioclase at 750 °C timescales are accurate (within 20%) above 10, 100, 2,600, and 71,000 years at 0.3, 1, 5, and 25 mm spatial resolution, respectively. For Sr diffusion in plagioclase at 750 °C, timescales are accurate above 0.02, 0.2, 4, and 120 years at the same spatial resolutions. Our results highlight the importance of selecting appropriate analytical techniques to estimate accurate diffusion-based timescales.
Distinctive soil organic matter composition in a precipitation contrast of a Hawaiian Andosol
NASA Astrophysics Data System (ADS)
Inagaki, Thiago M.; Grant, Katherine; Mueller, Carsten W.; Lehmann, Johannes; Derry, Louis A.; Kögel-Knabner, Ingrid
2017-04-01
Volcanic Andosols are recognized by their strong capacity to accumulate soil organic carbon (SOC), and for presenting a singular aggregation pattern. However, the factors which govern their SOC storage and aggregation hierarchy are still poorly understood. In addition, many methods of fractionation are proposed for these soils and there is no consensus regarding the ideal methodology. In this way, the objective of this study was to evaluate the soil organic matter (SOM) properties of an Andosol through CN analysis, NMR spectroscopy, and Scanning electron microscopy (SEM) + NanoSIMS analysis in the soil mineral fraction testing different dispersion treatments. We tested three Andosol samples from two different sites of the Kohala region - Hawaii with contrasting precipitation levels. The samples tested were as follow: 1784-60 (altitude-average depth cm) and 1784-80: subsoil samples from 0.5-0.7 and 0.7-0.9 m depth, respectively, with annual mean precipitation of 1784 mm and altitude of 1194 m; and 2286-50: subsoil sample from 45-60 cm depth, with annual mean precipitation of 2286 mm and altitude of 1501 m. We performed the SOM fractionation using ultrasonic dispersion at 1500 J ml-1, wet sieving and sedimentation. Five fractions were obtained as follow: free particulate organic matter (fPOM), 4000-63, 63-20, 20-2 and < 2µm, respectively. We made the fractionation procedure in two sets: with and without a pre-dispersion treatment with Na saturation to test its influence on the SOM characterization. The C content and distribution was analyzed in all the fractions, and the NMR and SEM+NanoSIMS analysis were carried out in the fraction <2µm of 1784-60 and 1784-80 samples. Overall, the pre-dispersion treatment with NaCL saturation did not influence the C content and its distribution, as well as the SOM composition observed by NMR and NanoSIMS analysis. More than 90% of the soil mass was concentrated in the fractions below 20 µm (i.e. 20-2 and <2µm). The <2µm fraction was the most representative for the evaluated Andosol, accounting with 83% of the C content and 74% of the soil mass for the three samples evaluated overall. The 2286-50 presented a higher C content than the other samples specially for fPOM and 63-20 µm fraction. The C and mass distribution along the fractions, on the other hand, was similar between the different soil samples. We observed a great difference in the SOM composition between the 1784-60 and 2286-50 samples in the mineral fraction (<2µm) through NMR spectroscopy. 2286-50 overall presented a dominance of alkyl-C, while 1784-60 presented higher amounts of carboxyl-C and O/N alkyl groups, which can be possibly be explained by differences in the mineral composition of each sample. Also the NanoSIMS analysis demonstrated distinct spatial differences in the distribution of 12C- and 12C14N- in organo-mineral associations at the micro scale between the two sites. The results of this study suggest that mineral interactions in the smaller size-fractions (<2µm) can be the key to explain the mechanisms of C storage in Andosols and that the pre-dispersion treatment with NaCL does not provide significant changes in the SOM study.
NASA Astrophysics Data System (ADS)
Yoshida, Y.; Matsumura, A.; Higeta, K.; Inoue, T.; Shimizu, S.; Motonami, Y.; Sato, M.; Sadahiro, T.; Fujii, K.
1991-07-01
The hardness depth profiles of cemented carbides which were implanted with high-energy B + ions have been estimated using a dynamic microhardness tester. The B + implantations into (16% Co)-cemented WC alloys were carried out under conditions where the implantation energies were 1-3 MeV and the fluences 1 × 10 17-1 × 10 18ions/cm 2. The profiles show that the implanted layer becomes harder as fluences are chosen at higher values and there is a peak at a certain depth which depends on the implantation energy. In X-ray diffraction (XRD) studies of the implanted surface the broadened refraction peaks of only WC and Co are detected and the increments of lattice strain and of residual stress in the near-surface region are observed. It is supposed that the hardening effect should be induced by an increase in residual stress produced by lattice strain. The hardness depth profile in successive implantation of ions with different energies agrees with the compounded profile of each one of the implantations. It is concluded that the hardness depth profile can be controlled under adequate conditions of implantation.
Topochemical Analysis of Cell Wall Components by TOF-SIMS.
Aoki, Dan; Fukushima, Kazuhiko
2017-01-01
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a recently developing analytical tool and a type of imaging mass spectrometry. TOF-SIMS provides mass spectral information with a lateral resolution on the order of submicrons, with widespread applicability. Sometimes, it is described as a surface analysis method without the requirement for sample pretreatment; however, several points need to be taken into account for the complete utilization of the capabilities of TOF-SIMS. In this chapter, we introduce methods for TOF-SIMS sample treatments, as well as basic knowledge of wood samples TOF-SIMS spectral and image data analysis.
Elemental and isotopic imaging of biological samples using NanoSIMS.
Kilburn, Matt R; Clode, Peta L
2014-01-01
With its low detection limits and the ability to analyze most of the elements in the periodic table, secondary ion mass spectrometry (SIMS) represents one of the most versatile in situ analytical techniques available, and recent developments have resulted in significant advantages for the use of imaging mass spectrometry in biological and biomedical research. Increases in spatial resolution and sensitivity allow detailed interrogation of samples at relevant scales and chemical concentrations. Advances in dynamic SIMS, specifically with the advent of NanoSIMS, now allow the tracking of stable isotopes within biological systems at subcellular length scales, while static SIMS combines subcellular imaging with molecular identification. In this chapter, we present an introduction to the SIMS technique, with particular reference to NanoSIMS, and discuss its application in biological and biomedical research.
NASA Astrophysics Data System (ADS)
Wirtz, T.; Philipp, P.; Audinot, J.-N.; Dowsett, D.; Eswara, S.
2015-10-01
Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM).
Hyperspectral Data Processing and Mapping of Soil Parameters: Preliminary Data from Tuscany (Italy)
NASA Astrophysics Data System (ADS)
Garfagnoli, F.; Moretti, S.; Catani, F.; Innocenti, L.; Chiarantini, L.
2010-12-01
Hyperspectral imaging has become a very powerful remote sensing tool for its capability of performing chemical and physical analysis of the observed areas. The objective of this study is to retrieve and characterize clay mineral content of the cultivated layer of soils, from both airborne hyperspectral and field spectrometry surveys in the 400-2500 nm spectral range. Correlation analysis is used to examine the possibility to predict the selected property using high-resolution reflectance spectra and images. The study area is located in the Mugello basin, about 30 km north of Firenze (Tuscany, Italy). Agriculturally suitable terrains are assigned mainly to annual crops, marginally to olive groves, vineyards and orchards. Soils mostly belong to Regosols and Cambisols orders. About 80 topsoil samples scattered all over the area were collected simultaneously with the flight of SIM.GA hyperspectral camera from Selex Galileo. The quantitative determination of clay minerals content in soil samples was performed by means of XRD and Rietveld refinement. An ASD FieldSpec spectroradiometer was used to obtain reflectance spectra from dried, crushed and sieved samples under controlled laboratory conditions. Different chemometric techniques (multiple linear regression, vertex component analysis, partial least squares regression and band depth analysis) were preliminarily tested to correlate mineralogical records with reflectance data. A one component partial least squares regression model yielded a preliminary R2 value of 0.65. A similar result was achieved by plotting the absorption peak depth at 2210 versus total clay mineral content (band-depth analysis). A complete hyperspectral geocoded reflectance dataset was collected using SIM.GA hyperspectral image sensor from Selex-Galileo, mounted on board of the University of Firenze ultra light aircraft. The approximate pixel resolution was 0.6 m (VNIR) and 1.2 m (SWIR). Airborne SIM.GA row data were firstly transformed into at-sensor radiance values, where calibration coefficients and parameters from laboratory measurements are applied to non-georeferred VNIR/SWIR DN values. Then, geocoded products are retrieved for each flight line by using a procedure developed in IDL Language and PARGE (PARametric Geocoding) software. When all compensation parameters are applied to hyperspectral data or to the final thematic map, orthorectified, georeferred and coregistered VNIR to SWIR images or maps are available for GIS application and 3D view. Airborne imagery has to be corrected for the influence of the atmosphere, solar illumination, sensor viewing geometry and terrain geometry information, for the retrieval of inherent surface reflectance properties. Then, different geophysical parameters can be investigated and retrieved by means of inversion algorithms. The experimental fitting of laboratory data on mineral content is used for airborne data inversion, whose results are in agreement with laboratory records, demonstrating the possibility to use this methodology for digital mapping of soil properties.
1986-04-01
method in fingerlinqs prey on sockeye salmon Puqet Sound to predict coho salmon fry ( Oncorhynchus nerka ); 30% of catches from stream discharqe data, coho...numbers of males distinguish it from chinook salmon and females in a soawninq run are sim- ( Oncorhynchus tshawytscha), which have ilar males may...behind sockeye salmon (qnco- qoal is te umber of spawners rhynchus nerka ), pink salmon (. necesar) to majinta1n the run of a -orhuscha), and chum salmon
Lombardi, Michael A.; Novick, Andrew N.; Lopez R, J. Mauricio; Jimenez, Francisco; de Carlos Lopez, Eduardo; Boulanger, Jean-Simon; Pelletier, Raymond; de Carvalho, Ricardo J.; Solis, Raul; Sanchez, Harold; Quevedo, Carlos Andres; Pascoe, Gregory; Perez, Daniel; Bances, Eduardo; Trigo, Leonardo; Masi, Victor; Postigo, Henry; Questelles, Anthony; Gittens, Anselm
2011-01-01
The Sistema Interamericano de Metrologia (SIM) is a regional metrology organization (RMO) whose members are the national metrology institutes (NMIs) located in the 34 nations of the Organization of American States (OAS). The SIM/OAS region extends throughout North, Central, and South America and the Caribbean Islands. About half of the SIM NMIs maintain national standards of time and frequency and must participate in international comparisons in order to establish metrological traceability to the International System (SI) of units. The SIM time network (SIMTN) was developed as a practical, cost effective, and technically sound way to automate these comparisons. The SIMTN continuously compares the time standards of SIM NMIs and produces measurement results in near real-time by utilizing the Internet and the Global Positioning System (GPS). Fifteen SIM NMIs have joined the network as of December 2010. This paper provides a brief overview of SIM and a technical description of the SIMTN. It presents international comparison results and examines the measurement uncertainties. It also discusses the metrological benefits that the network provides to its participants. PMID:26989584
Lombardi, Michael A; Novick, Andrew N; Lopez R, J Mauricio; Jimenez, Francisco; de Carlos Lopez, Eduardo; Boulanger, Jean-Simon; Pelletier, Raymond; de Carvalho, Ricardo J; Solis, Raul; Sanchez, Harold; Quevedo, Carlos Andres; Pascoe, Gregory; Perez, Daniel; Bances, Eduardo; Trigo, Leonardo; Masi, Victor; Postigo, Henry; Questelles, Anthony; Gittens, Anselm
2011-01-01
The Sistema Interamericano de Metrologia (SIM) is a regional metrology organization (RMO) whose members are the national metrology institutes (NMIs) located in the 34 nations of the Organization of American States (OAS). The SIM/OAS region extends throughout North, Central, and South America and the Caribbean Islands. About half of the SIM NMIs maintain national standards of time and frequency and must participate in international comparisons in order to establish metrological traceability to the International System (SI) of units. The SIM time network (SIMTN) was developed as a practical, cost effective, and technically sound way to automate these comparisons. The SIMTN continuously compares the time standards of SIM NMIs and produces measurement results in near real-time by utilizing the Internet and the Global Positioning System (GPS). Fifteen SIM NMIs have joined the network as of December 2010. This paper provides a brief overview of SIM and a technical description of the SIMTN. It presents international comparison results and examines the measurement uncertainties. It also discusses the metrological benefits that the network provides to its participants.
Target-depth estimation in active sonar: Cramer-Rao bounds for a bilinear sound-speed profile.
Mours, Alexis; Ioana, Cornel; Mars, Jérôme I; Josso, Nicolas F; Doisy, Yves
2016-09-01
This paper develops a localization method to estimate the depth of a target in the context of active sonar, at long ranges. The target depth is tactical information for both strategy and classification purposes. The Cramer-Rao lower bounds for the target position as range and depth are derived for a bilinear profile. The influence of sonar parameters on the standard deviations of the target range and depth are studied. A localization method based on ray back-propagation with a probabilistic approach is then investigated. Monte-Carlo simulations applied to a summer Mediterranean sound-speed profile are performed to evaluate the efficiency of the estimator. This method is finally validated on data in an experimental tank.
NASA Astrophysics Data System (ADS)
Mohajernia, Shiva; Mazare, Anca; Hwang, Imgon; Gaiaschi, Sofia; Chapon, Patrick; Hildebrand, Helga; Schmuki, Patrik
2018-06-01
In this work we study the depth composition of anodic TiO2 nanotube layers. We use elemental depth profiling with Glow Discharge Optical Emission Spectroscopy and calibrate the results of this technique with X-ray photoelectron spectroscopy (XPS) and energy dispersive spectroscopy (EDS). We establish optimized sputtering conditions for nanotubular structures using the pulsed RF mode, which causes minimized structural damage during the depth profiling of the nanotubular structures. This allows to obtain calibrated sputter rates that account for the nanotubular "porous" morphology. Most importantly, sputter-artifact free compositional profiles of these high aspect ratio 3D structures are obtained, as well as, in combination with SEM, elegant depth sectional imaging.
Principles of operation, accuracy and precision of an Eye Surface Profiler.
Iskander, D Robert; Wachel, Pawel; Simpson, Patrick N D; Consejo, Alejandra; Jesus, Danilo A
2016-05-01
To introduce a newly developed instrument for measuring the topography of the anterior eye, provide principles of its operation and to assess its accuracy and precision. The Eye Surface Profiler is a new technology based on Fourier transform profilometry for measuring the anterior eye surface encompassing the corneo-scleral area. Details of technical principles of operation are provided for the particular case of sequential double fringe projection. Technical limits of accuracy have been assessed for several key parameters such as the carrier frequency, image quantisation level, sensor size, carrier frequency inaccuracy, and level and type of noise. Further, results from both artificial test surfaces as well as real eyes are used to assess precision and accuracy of the device (here benchmarked against one of popular Placido disk videokeratoscopes). Technically, the Eye Surface Profiler accuracy can reach levels below 1 μm for a range of considered key parameters. For the unit tested and using calibrated artificial surfaces, the accuracy of measurement (in terms of RMS error) was below 10 μm for a central measurement area of 8 mm diameter and below 40 μm for an extended measurement area of 16 mm. In some cases, the error reached levels of up to 200 μm at the very periphery of the measured surface (up to 20 mm). The SimK estimates of the test surfaces from the Eye Surface Profiler were in close agreement with those from a Placido disk videokeratoscope with differences no greater than ±0.1 D. For real eyes, the benchmarked accuracy was within ±0.5D for both the spherical and cylindrical SimK components. The Eye Surface Profiler can successfully measure the topography of the entire anterior eye including the cornea, limbus and sclera. It has a great potential to become an optometry clinical tool that could substitute the currently used videokeratoscopes and provide a high quality corneo-scleral topography. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Heavy doping of CdTe single crystals by Cr ion implantation
NASA Astrophysics Data System (ADS)
Popovych, Volodymyr D.; Böttger, Roman; Heller, Rene; Zhou, Shengqiang; Bester, Mariusz; Cieniek, Bogumil; Mroczka, Robert; Lopucki, Rafal; Sagan, Piotr; Kuzma, Marian
2018-03-01
Implantation of bulk CdTe single crystals with high fluences of 500 keV Cr+ ions was performed to achieve Cr concentration above the equilibrium solubility limit of this element in CdTe lattice. The structure and composition of the implanted samples were studied using secondary ion mass spectrometry (SIMS), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis, X-ray diffraction (XRD) and Rutherford backscattering spectrometry (RBS) to characterize the incorporation of chromium into the host lattice and to investigate irradiation-induced damage build-up. It was found that out-diffusion of Cr atoms and sputtering of the targets alter the depth distribution and limit concentration of the projectile ions in the as-implanted samples. Appearance of crystallographically oriented, metallic α-Cr nanoparticles inside CdTe matrix was found after implantation, as well as a strong disorder at the depth far beyond the projected range of the implanted ions.
High-temperature Au implantation into Ni-Be and Ni-Si alloys
NASA Astrophysics Data System (ADS)
James, M. R.; Lam, N. Q.; Rehn, L. E.; Baldo, P. M.; Funk, L.; Stubbins, J. F.
1992-12-01
Effects of implantation temperature and target composition on depth distribution of implanted species were investigated. Au+ ions were implanted at 300 keV into polycrystalline Ni-Be and Ni-Si alloys between 25 and 700C to a dose of 10(exp 16) cm(exp -2). Depth distributions of Au were analyzed with RBS using He+ at both 1.7 and 3.0 MeV, and those of the other alloying elements by SIMS. Theoretical modeling of compositional redistribution during implantation at elevated temperatures was also carried out with the aid of a comprehensive kinetic model. The analysis indicated that below approximately 250C, the primary controlling processes were preferential sputtering and displacement mixing, while between 250 and 600C radiation-induced segregation was dominant. Above 600C, thermal-diffusion effects were most important. Fitting of model calculations to experimental measurements provided values for various defect migration and formation parameters.
Using a simulation cell for exercise realism.
Lerner, Ken
2013-01-01
A simulation cell or SimCell is an effective and flexible tool for control of emergency management exercises. It allows exercise participants to interact, via simulation, with a wide variety of nonplaying organizations and officials. Adapted from military application, the Chemical Stockpile Emergency Preparedness Program (CSEPP) applied, developed, and refined the SimCell concept for emergency management exercises. It has now been incorporated into national exercise guidance through the Homeland Security Exercise and Evaluation Program, and has been used in a wide variety of national, regional, and local exercises. This article reviews development of the SimCell concept in CSEPP, briefly surveys current practice incorporating SimCells in exercise control, and offers practical lessons-learned and tips on using a SimCell to best advantage. Lessons learned include using a SimCell as an exercise-control hub; preparing inject material for exercise controllers as part of the Master Scenario Event List; laying the groundwork for success through exercise player and controller training; developing protocol for SimCell communications; and capturing feedback from SimCell controllers for inclusion in the exercise evaluation reporting process. The SimCell concept is flexible and can be applied to a variety of exercise types and through a variety of methods.
Fundamental limits to superresolution fluorescence microscopy
NASA Astrophysics Data System (ADS)
Small, Alex
2013-02-01
Superresolution fluorescence microscopy techniques such as PALM, STORM, STED, and Structured Illumination Microscopy (SIM) enable imaging of live cells at nanometer resolution. The common theme in all of these techniques is that the diffraction limit is circumvented by controlling the states of fluorescent molecules. Although the samples are labeled very densely (i.e. with spacing much smaller than the Airy distance), not all of the molecules are emitting at the same time. Consequently, one does not encounter overlapping blurs. In the deterministic techniques (STED, SIM) the achievable resolution scales as the wavelength of light divided by the square root of the intensity of a beam used to control the fluorescent state. In the stochastic techniques (PALM, STORM), the achievable resolution scales as the wavelength of light divided by the square root of the number of photons collected. Although these limits arise from very different mechanisms (parabolic beam profiles for STED and SIM, statistics for PALM and STORM), in all cases the resolution scales inversely with the square root of a measure of the number of photons used in the experiment. We have developed a proof that this relationship between resolution and photon count is universal to techniques that control the states of fluorophores using classical light. Our proof encompasses linear and nonlinear optics, as well as computational post-processing techniques for extracting information beyond the diffraction limit. If there are techniques that can achieve a more efficient relationship between resolution and photon count, those techniques will require light exhibiting non-classical correlations.
CalSimHydro Tool - A Web-based interactive tool for the CalSim 3.0 Hydrology Prepropessor
NASA Astrophysics Data System (ADS)
Li, P.; Stough, T.; Vu, Q.; Granger, S. L.; Jones, D. J.; Ferreira, I.; Chen, Z.
2011-12-01
CalSimHydro, the CalSim 3.0 Hydrology Preprocessor, is an application designed to automate the various steps in the computation of hydrologic inputs for CalSim 3.0, a water resources planning model developed jointly by California State Department of Water Resources and United States Bureau of Reclamation, Mid-Pacific Region. CalSimHydro consists of a five-step FORTRAN based program that runs the individual models in succession passing information from one model to the next and aggregating data as required by each model. The final product of CalSimHydro is an updated CalSim 3.0 state variable (SV) DSS input file. CalSimHydro consists of (1) a Rainfall-Runoff Model to compute monthly infiltration, (2) a Soil moisture and demand calculator (IDC) that estimates surface runoff, deep percolation, and water demands for natural vegetation cover and various crops other than rice, (3) a Rice Water Use Model to compute the water demands, deep percolation, irrigation return flow, and runoff from precipitation for the rice fields, (4) a Refuge Water Use Model that simulates the ponding operations for managed wetlands, and (5) a Data Aggregation and Transfer Module to aggregate the outputs from the above modules and transfer them to the CalSim SV input file. In this presentation, we describe a web-based user interface for CalSimHydro using Google Earth Plug-In. The CalSimHydro tool allows users to - interact with geo-referenced layers of the Water Budget Areas (WBA) and Demand Units (DU) displayed over the Sacramento Valley, - view the input parameters of the hydrology preprocessor for a selected WBA or DU in a time series plot or a tabular form, - edit the values of the input parameters in the table or by downloading a spreadsheet of the selected parameter in a selected time range, - run the CalSimHydro modules in the backend server and notify the user when the job is done, - visualize the model output and compare it with a base run result, - download the output SV file to be used to run CalSim 3.0. The CalSimHydro tool streamlines the complicated steps to configure and run the hydrology preprocessor by providing a user-friendly visual interface and back-end services to validate user inputs and manage the model execution. It is a powerful addition to the new CalSim 3.0 system.
NASA Astrophysics Data System (ADS)
Kang, Young C.
The following work is the study to evaluate the impact of corrosion inhibitors on the copper metal in drinking water and to investigate the corrosion mechanism in the presence and absence of inhibitors. Electrochemical experiments were conducted to understand the effect of specific corrosion inhibitors in synthetic drinking water which was prepared with controlled specific water quality parameters. Water chemistry was studied by Inductively Coupled Plasma--Atomic Emission Spectroscopy (ICP--AES) to investigate the copper leaching rate with time. Surface morphology, crystallinity of corrosion products, copper oxidation status, and surface composition were characterized by various solid surface analysis methods, such as Scanning Electron Microscopy/Energy--Dispersive Spectrometry (SEM/EDS), Grazing-Incidence-angle X-ray Diffraction (GIXRD), X-ray Photoelectron Spectroscopy (XPS), and Time-of-Flight Secondary Ions Mass Spectrometry (ToF-SIMS). The purpose of the first set of experiments was to test various electrochemical techniques for copper corrosion for short term before studying a long term loop system. Surface analysis techniques were carried out to identify and study the corrosion products that form on the fresh copper metal surface when copper coupons were exposed to test solutions for 2 days of experiments time. The second phase of experiments was conducted with a copper pipe loop system in a synthetic tap water over an extended period of time, i.e., 4 months. Copper release and electrochemically measured corrosion activity profiles were monitored carefully with and without corrosion inhibitor, polyphosphate. A correlation between the copper released into the solution and the electrochemically measured corrosion activities was also attempted. To investigate corrosion products on the copper pipe samples, various surface analysis techniques were applied in this study. Especially, static mass spectra acquisition and element distribution mapping were carried out by ToF-SIMS. Dynamic SIMS provided shallow depth profile of corroded copper sample. The third set of the experiments was related to electrochemical noise (EN) measurement through copper coupons to pipes. Calculating corrosion rate of a metal and predicting exactly how long it lasts are problematic since the metal corrosion may be caused by combined corrosion types. Many other metals undergo not only uniform corrosion, but localized corrosion. Uniform corrosion may be conducive for copper pipe to prevent it from further severe corrosion and form passivated film, but localized corrosion causes pinhole leaks and limits the copper pipe applications. The objective of this set of experiment is to discuss the application of electrochemical noise approaches to drinking water copper corrosion problems. Specially, a fundamental description of EN is presented including a discussion of how to interpret the results and technique limitations. Although it was indicated with electrochemical analysis that the corrosion activity was affected by orthophosphate addition in the short-term test, no copper-phosphate complex or compound was found by copper surface characterization. Apparently, orthophosphate can inhibit corrosion by adsorption on the copper surface, but cannot form solid complexes with copper in such a short time, 2 days. When polyphosphate was added into recirculating copper pipe system, copper level increased and polarization resistance decreased. Greenish blue residue on the copper pipe was suspected as copper phosphate complex and corrosion inhibition mechanism was proposed.
Simvastatin Prodrug Micelles Target Fracture and Improve Healing
Dusad, Anand; Yuan, Hongjiang; Ren, Ke; Li, Fei; Fehringer, Edward V.; Purdue, P. Edward; Goldring, Steven R.; Daluiski, Aaron; Wang, Dong
2014-01-01
Simvastatin (SIM), a widely used anti-lipidaemic drug, has been identified as a bone anabolic agent. Its poor water solubility and the lack of distribution to the skeleton, however, have limited its application in the treatment of bone metabolic diseases. In this study, an amphiphilic macromolecular prodrug of SIM was designed and synthesized to overcome these limitations. The polyethylene glycol (PEG)-based prodrug can spontaneously self-assemble to form micelles. The use of SIM trimer as the prodrug’s hydrophobic segment allows easy encapsulation of additional free SIM. The in vitro studies showed that SIM/SIM-mPEG micelles were internalized by MC3T3 cells via lysosomal trafficking and consistently induced expression of both BMP2 and DKK1 mRNA, suggesting that the prodrug micelle retains the biological functions of SIM. After systemic administration, optical imaging suggests that the micelles would passively target to bone fracture sites associated with hematoma and inflammation. Furthermore, flow cytometry study revealed that SIM/SIM-mPEG micelles had preferred cellular uptake by inflammatory and resident cells within the fracture callus tissue. The treatment study using a mouse osteotomy model validated the micelles’ therapeutic efficacy in promoting bone fracture healing as demonstrated by micro-CT and histological analyses. Collectively, these data suggest that the macromolecular prodrug-based micelle formulation of SIM may have great potential for clinical management of impaired fracture healing. PMID:25542644
MS/MS analysis and imaging of lipids across Drosophila brain using secondary ion mass spectrometry.
Phan, Nhu T N; Munem, Marwa; Ewing, Andrew G; Fletcher, John S
2017-06-01
Lipids are abundant biomolecules performing central roles to maintain proper functioning of cells and biological bodies. Due to their highly complex composition, it is critical to obtain information of lipid structures in order to identify particular lipids which are relevant for a biological process or metabolic pathway under study. Among currently available molecular identification techniques, MS/MS in secondary ion mass spectrometry (SIMS) imaging has been of high interest in the bioanalytical community as it allows visualization of intact molecules in biological samples as well as elucidation of their chemical structures. However, there have been few applications using SIMS and MS/MS owing to instrumental challenges for this capability. We performed MS and MS/MS imaging to study the lipid structures of Drosophila brain using the J105 and 40-keV Ar 4000 + gas cluster ion source, with the novelty being the use of MS/MS SIMS analysis of intact lipids in the fly brain. Glycerophospholipids were identified by MS/MS profiling. MS/MS was also used to characterize diglyceride fragment ions and to identify them as triacylglyceride fragments. Moreover, MS/MS imaging offers a unique possibility for detailed elucidation of biomolecular distribution with high accuracy based on the ion images of its fragments. This is particularly useful in the presence of interferences which disturb the interpretation of biomolecular localization. Graphical abstract MS/MS was performed during time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of Drosophila melongaster (fruit fly) to elucidate the structure and origin of different chemical species in the brain including a range of different phospholipid classes (PC, PI, PE) and di- and triacylglycerides (DAG & TAG) species where reference MS/MS spectra provided a potential means of discriminating between the isobaric [M-OH] + ion of DAGs and the [M-RCO] + ion of TAGs.
Wern, Jeanette Erbo; Sorensen, Maria Rathmann; Olsen, Anja Weinreich; Andersen, Peter; Follmann, Frank
2017-01-01
The selection of any specific immunization route is critical when defining future vaccine strategies against a genital infection like Chlamydia trachomatis (C.t.). An optimal Chlamydia vaccine needs to elicit mucosal immunity comprising both neutralizing IgA/IgG antibodies and strong Th1/Th17 responses. A strategic tool to modulate this immune profile and mucosal localization of vaccine responses is to combine parenteral and mucosal immunizations routes. In this study, we investigate whether this strategy can be adapted into a two-visit strategy by simultaneous subcutaneous (SC) and nasal immunization. Using a subunit vaccine composed of C.t. antigens (Ags) adjuvanted with CAF01, a Th1/Th17 promoting adjuvant, we comparatively evaluated Ag-specific B and T cell responses and efficacy in mice following SC and simultaneous SC and nasal immunization (SIM). We found similar peripheral responses with regard to interferon gamma and IL-17 producing Ag-specific splenocytes and IgG serum levels in both vaccine strategies but in addition, the SIM protocol also led to Ag-specific IgA responses and increased B and CD4+ T cells in the lung parenchyma, and in lower numbers also in the genital tract (GT). Following vaginal infection with C.t., we observed that SIM immunization gave rise to an early IgA response and IgA-secreting plasma cells in the GT in contrast to SC immunization, but we were not able to detect more rapid recruitment of mucosal T cells. Interestingly, although SIM vaccination in general improved mucosal immunity we observed no improved efficacy against genital infection compared to SC, a finding that warrants for further investigation. In conclusion, we demonstrate a novel vaccination strategy that combines systemic and mucosal immunity in a two-visit strategy. PMID:28567043
On the merging cluster Abell 578 and its central radio galaxy 4C+67.13
Hagino, K.; Stawarz, Ł.; Siemiginowska, A.; ...
2015-05-26
Here we analyze radio, optical, and X-ray data for the peculiar cluster Abell 578. This cluster is not fully relaxed and consists of two merging sub-systems. The brightest cluster galaxy (BCG), CGPG 0719.8+6704, is a pair of interacting ellipticals with projected separation ~10 kpc, the brighter of which hosts the radio source 4C+67.13. The Fanaroff–Riley type-II radio morphology of 4C+67.13 is unusual for central radio galaxies in local Abell clusters. Our new optical spectroscopy revealed that both nuclei of the CGPG 0719.8+6704 pair are active, albeit at low accretion rates corresponding to the Eddington ratiomore » $$\\sim {{10}^{-4}}$$ (for the estimated black hole masses of $$\\sim 3\\times {{10}^{8}}\\;{{M}_{\\odot }}$$ and $$\\sim {{10}^{9}}\\;{{M}_{\\odot }}$$). The gathered X-ray (Chandra) data allowed us to confirm and to quantify robustly the previously noted elongation of the gaseous atmosphere in the dominant sub-cluster, as well as a large spatial offset (~60 kpc projected) between the position of the BCG and the cluster center inferred from the modeling of the X-ray surface brightness distribution. Detailed analysis of the brightness profiles and temperature revealed also that the cluster gas in the vicinity of 4C+67.13 is compressed (by a factor of about ~1.4) and heated (from $$\\simeq 2.0$$ keV up to 2.7 keV), consistent with the presence of a weak shock (Mach number ~1.3) driven by the expanding jet cocoon. As a result, this would then require the jet kinetic power of the order of $$\\sim {{10}^{45}}$$ erg s –1, implying either a very high efficiency of the jet production for the current accretion rate, or a highly modulated jet/accretion activity in the system.« less
NASA Astrophysics Data System (ADS)
García, I.; Rey-Stolle, I.; Galiana, B.; Algora, C.
2007-01-01
The use of tellurium as n-type dopant for GaAs and InP has several advantages, including a high incorporation efficiency, the very high doping levels achievable and a low diffusion coefficient. However, its use to dope Ga xIn 1-xP is not straightforward, since it shows several problems like a remarkable memory effect and an acute inertia of the material to become Te-doped, which gives rise to gradual doping profiles. In this paper, all these phenomena are studied and quantified using secondary ion mass spectroscopy (SIMS) and electrochemical CV profiling (ECV) measurements. Concerning the gradual doping profiles, their origin is linked to the interaction of Te and In in the gas phase and on the growth surface. A phenomenological explanation is given for this effect although the exact physical processes behind remain to be defined.
Depth Profilometry via Multiplexed Optical High-Coherence Interferometry
Kazemzadeh, Farnoud; Wong, Alexander; Behr, Bradford B.; Hajian, Arsen R.
2015-01-01
Depth Profilometry involves the measurement of the depth profile of objects, and has significant potential for various industrial applications that benefit from non-destructive sub-surface profiling such as defect detection, corrosion assessment, and dental assessment to name a few. In this study, we investigate the feasibility of depth profilometry using an Multiplexed Optical High-coherence Interferometry MOHI instrument. The MOHI instrument utilizes the spatial coherence of a laser and the interferometric properties of light to probe the reflectivity as a function of depth of a sample. The axial and lateral resolutions, as well as imaging depth, are decoupled in the MOHI instrument. The MOHI instrument is capable of multiplexing interferometric measurements into 480 one-dimensional interferograms at a location on the sample and is built with axial and lateral resolutions of 40 μm at a maximum imaging depth of 700 μm. Preliminary results, where a piece of sand-blasted aluminum, an NBK7 glass piece, and an optical phantom were successfully probed using the MOHI instrument to produce depth profiles, demonstrate the feasibility of such an instrument for performing depth profilometry. PMID:25803289
Depth profilometry via multiplexed optical high-coherence interferometry.
Kazemzadeh, Farnoud; Wong, Alexander; Behr, Bradford B; Hajian, Arsen R
2015-01-01
Depth Profilometry involves the measurement of the depth profile of objects, and has significant potential for various industrial applications that benefit from non-destructive sub-surface profiling such as defect detection, corrosion assessment, and dental assessment to name a few. In this study, we investigate the feasibility of depth profilometry using an Multiplexed Optical High-coherence Interferometry MOHI instrument. The MOHI instrument utilizes the spatial coherence of a laser and the interferometric properties of light to probe the reflectivity as a function of depth of a sample. The axial and lateral resolutions, as well as imaging depth, are decoupled in the MOHI instrument. The MOHI instrument is capable of multiplexing interferometric measurements into 480 one-dimensional interferograms at a location on the sample and is built with axial and lateral resolutions of 40 μm at a maximum imaging depth of 700 μm. Preliminary results, where a piece of sand-blasted aluminum, an NBK7 glass piece, and an optical phantom were successfully probed using the MOHI instrument to produce depth profiles, demonstrate the feasibility of such an instrument for performing depth profilometry.
High Spectral Resolution Lidar Data
Eloranta, Ed
2004-12-01
The HSRL provided calibrated vertical profiles of optical depth, backscatter cross section and depoloarization at a wavelength of 532 nm. Profiles were acquired at 2.5 second intervals with 7.5 meter resolution. Profiles extended from an altitude of 100 m to 30 km in clear air. The lidar penetrated to a maximum optical depth of ~ 4 under cloudy conditions. Our data contributed directly to the aims of the M-PACE experiment, providing calibrated optical depth and optical backscatter measurements which were not available from any other instrument.
Sadek, H.S.; Rashad, S.M.; Blank, H.R.
1984-01-01
If proper account is taken of the constraints of the method, it is capable of providing depth estimates to within an accuracy of about 10 percent under suitable circumstances. The estimates are unaffected by source magnetization and are relatively insensitive to assumptions as to source shape or distribution. The validity of the method is demonstrated by analyses of synthetic profiles and profiles recorded over Harrat Rahat, Saudi Arabia, and Diyur, Egypt, where source depths have been proved by drilling.
Evaluation of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction
NASA Technical Reports Server (NTRS)
Jones, M. G.; Watson, W. R.; Nark, D. M.; Howerton, B. M.
2015-01-01
This paper explores the effects of variable-depth geometry on the amount of noise reduction that can be achieved with acoustic liners. Results for two variable-depth liners tested in the NASA Langley Grazing Flow Impedance Tube demonstrate significant broadband noise reduction. An impedance prediction model is combined with two propagation codes to predict corresponding sound pressure level profiles over the length of the Grazing Flow Impedance Tube. The comparison of measured and predicted sound pressure level profiles is sufficiently favorable to support use of these tools for investigation of a number of proposed variable-depth liner configurations. Predicted sound pressure level profiles for these proposed configurations reveal a number of interesting features. Liner orientation clearly affects the sound pressure level profile over the length of the liner, but the effect on the total attenuation is less pronounced. The axial extent of attenuation at an individual frequency continues well beyond the location where the liner depth is optimally tuned to the quarter-wavelength of that frequency. The sound pressure level profile is significantly affected by the way in which variable-depth segments are distributed over the length of the liner. Given the broadband noise reduction capability for these liner configurations, further development of impedance prediction models and propagation codes specifically tuned for this application is warranted.
Franzen, Lutz; Anderski, Juliane; Windbergs, Maike
2015-09-01
For rational development and evaluation of dermal drug delivery, the knowledge of rate and extent of substance penetration into the human skin is essential. However, current analytical procedures are destructive, labor intense and lack a defined spatial resolution. In this context, confocal Raman microscopy bares the potential to overcome current limitations in drug depth profiling. Confocal Raman microscopy already proved its suitability for the acquisition of qualitative penetration profiles, but a comprehensive investigation regarding its suitability for quantitative measurements inside the human skin is still missing. In this work, we present a systematic validation study to deploy confocal Raman microscopy for quantitative drug depth profiling in human skin. After we validated our Raman microscopic setup, we successfully established an experimental procedure that allows correlating the Raman signal of a model drug with its controlled concentration in human skin. To overcome current drawbacks in drug depth profiling, we evaluated different modes of peak correlation for quantitative Raman measurements and offer a suitable operating procedure for quantitative drug depth profiling in human skin. In conclusion, we successfully demonstrate the potential of confocal Raman microscopy for quantitative drug depth profiling in human skin as valuable alternative to destructive state-of-the-art techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
Fu, Henry L.; Mueller, Jenna L.; Javid, Melodi P.; Mito, Jeffrey K.; Kirsch, David G.; Ramanujam, Nimmi; Brown, J. Quincy
2013-01-01
Cancer is associated with specific cellular morphological changes, such as increased nuclear size and crowding from rapidly proliferating cells. In situ tissue imaging using fluorescent stains may be useful for intraoperative detection of residual cancer in surgical tumor margins. We developed a widefield fluorescence structured illumination microscope (SIM) system with a single-shot FOV of 2.1×1.6 mm (3.4 mm2) and sub-cellular resolution (4.4 µm). The objectives of this work were to measure the relationship between illumination pattern frequency and optical sectioning strength and signal-to-noise ratio in turbid (i.e. thick) samples for selection of the optimum frequency, and to determine feasibility for detecting residual cancer on tumor resection margins, using a genetically engineered primary mouse model of sarcoma. The SIM system was tested in tissue mimicking solid phantoms with various scattering levels to determine impact of both turbidity and illumination frequency on two SIM metrics, optical section thickness and modulation depth. To demonstrate preclinical feasibility, ex vivo 50 µm frozen sections and fresh intact thick tissue samples excised from a primary mouse model of sarcoma were stained with acridine orange, which stains cell nuclei, skeletal muscle, and collagenous stroma. The cell nuclei were segmented using a high-pass filter algorithm, which allowed quantification of nuclear density. The results showed that the optimal illumination frequency was 31.7 µm−1 used in conjunction with a 4×0.1 NA objective ( = 0.165). This yielded an optical section thickness of 128 µm and an 8.9×contrast enhancement over uniform illumination. We successfully demonstrated the ability to resolve cell nuclei in situ achieved via SIM, which allowed segmentation of nuclei from heterogeneous tissues in the presence of considerable background fluorescence. Specifically, we demonstrate that optical sectioning of fresh intact thick tissues performed equivalently in regards to nuclear density quantification, to physical frozen sectioning and standard microscopy. PMID:23894357
Direct depth distribution measurement of deuterium in bulk tungsten exposed to high-flux plasma
Taylor, Chase N.; Shimada, M.
2017-05-08
Understanding tritium retention and permeation in plasma-facing components is critical for fusion safety and fuel cycle control. Glow discharge optical emission spectroscopy (GD-OES) is shown to be an effective tool to reveal the depth profile of deuterium in tungsten. Results confirm the detection of deuterium. Furthermore, a ~46 µm depth profile revealed that the deuterium content decreased precipitously in the first 7 µm, and detectable amounts were observed to depths in excess of 20 µm. The large probing depth of GD-OES (up to 100s of µm) enables studies not previously accessible to the more conventional techniques for investigating deuterium retention.more » Of particular applicability is the use of GD-OES to measure the depth profile for experiments where high diffusion is expected: deuterium retention in neutron irradiated materials, and ultra-high deuterium fluences in burning plasma environment.« less
Direct depth distribution measurement of deuterium in bulk tungsten exposed to high-flux plasma
NASA Astrophysics Data System (ADS)
Taylor, C. N.; Shimada, M.
2017-05-01
Understanding tritium retention and permeation in plasma-facing components is critical for fusion safety and fuel cycle control. Glow discharge optical emission spectroscopy (GD-OES) is shown to be an effective tool to reveal the depth profile of deuterium in tungsten. Results confirm the detection of deuterium. A ˜46 μm depth profile revealed that the deuterium content decreased precipitously in the first 7 μm, and detectable amounts were observed to depths in excess of 20 μm. The large probing depth of GD-OES (up to 100s of μm) enables studies not previously accessible to the more conventional techniques for investigating deuterium retention. Of particular applicability is the use of GD-OES to measure the depth profile for experiments where high deuterium concentration in the bulk material is expected: deuterium retention in neutron irradiated materials, and ultra-high deuterium fluences in burning plasma environment.
Depth profiling of ion-induced damage in D9 alloy using X-ray diffraction
NASA Astrophysics Data System (ADS)
Dey, S.; Gayathri, N.; Mukherjee, P.
2018-04-01
The ion-induced depthwise damage profile in 35 MeV α-irradiated D9 alloy samples with doses of 5 × 1015 He2+/cm2, 6.4 × 1016 He2+/cm2 and 2 × 1017 He2+/cm2 has been assessed using X-ray diffraction technique. The microstructural characterisation has been done along the depth from beyond the stopping region (peak damage region) to the homogeneous damage region (surface) as simulated from SRIM. The parameters such as domain size and microstrain have been evaluated using two different X-ray diffraction line profile analysis techniques. The results indicate that at low dose the damage profile shows a prominent variation as a function of depth but, with increasing dose, it becomes more homogeneous along the depth. This suggests that enhanced defect diffusion and their annihilation in pre-existing and newly formed sinks play a significant role in deciding the final microstructure of the irradiated sample as a function of depth.
Barreto, Goncalo; Soininen, Antti; Sillat, Tarvo; Konttinen, Yrjö T; Kaivosoja, Emilia
2014-01-01
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is increasingly being used in analysis of biological samples. For example, it has been applied to distinguish healthy and osteoarthritic human cartilage. This chapter discusses ToF-SIMS principle and instrumentation including the three modes of analysis in ToF-SIMS. ToF-SIMS sets certain requirements for the samples to be analyzed; for example, the samples have to be vacuum compatible. Accordingly, sample processing steps for different biological samples, i.e., proteins, cells, frozen and paraffin-embedded tissues and extracellular matrix for the ToF-SIMS are presented. Multivariate analysis of the ToF-SIMS data and the necessary data preprocessing steps (peak selection, data normalization, mean-centering, and scaling and transformation) are discussed in this chapter.
Poly-Small Ubiquitin-like Modifier (PolySUMO)-binding Proteins Identified through a String Search*
Sun, Huaiyu; Hunter, Tony
2012-01-01
Polysumoylation is a crucial cellular response to stresses against genomic integrity or proteostasis. Like the small ubiquitin-like modifier (SUMO)-targeted ubiquitin ligase RNF4, proteins with clustered SUMO-interacting motifs (SIMs) can be important signal transducers downstream of polysumoylation. To identify novel polySUMO-binding proteins, we conducted a computational string search with a custom Python script. We found clustered SIMs in another RING domain protein Arkadia/RNF111. Detailed biochemical analysis of the Arkadia SIMs revealed that dominant SIMs in a SIM cluster often contain a pentameric VIDLT ((V/I/L/F/Y)(V/I)DLT) core sequence that is also found in the SIMs in PIAS family E3s and is likely the best-fitted structure for SUMO recognition. This idea led to the identification of additional novel SIM clusters in FLASH/CASP8AP2, C5orf25, and SOBP/JXC1. We suggest that the clustered SIMs in these proteins form distinct SUMO binding domains to recognize diverse forms of protein sumoylation. PMID:23086935
2013-01-01
The influence of lattice strain on the oxygen exchange kinetics and diffusion in oxides was investigated on (100) epitaxial La1–xSrxCoO3−δ (LSC) thin films grown by pulsed laser deposition. Planar tensile and compressively strained LSC films were obtained on single-crystalline SrTiO3 and LaAlO3. 18O isotope exchange depth profiling with ToF-SIMS was employed to simultaneously measure the tracer surface exchange coefficient k* and the tracer diffusion coefficient D* in the temperature range 280–475 °C. In accordance with recent theoretical findings, much faster surface exchange (∼4 times) and diffusion (∼10 times) were observed for the tensile strained films compared to the compressively strained films in the entire temperature range. The same strain effect—tensile strain leading to higher k* and D*—was found for different LSC compositions (x = 0.2 and x = 0.4) and for surface-etched films. The temperature dependence of k* and D* is discussed with respect to the contributions of strain states, formation enthalpy of oxygen vacancies, and vacancy mobility at different temperatures. Our findings point toward the control of oxygen surface exchange and diffusion kinetics by means of lattice strain in existing mixed conducting oxides for energy conversion applications. PMID:23527691
CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry
NASA Astrophysics Data System (ADS)
Tian, Hua; Maciążek, Dawid; Postawa, Zbigniew; Garrison, Barbara J.; Winograd, Nicholas
2016-09-01
The emergence of argon-based gas cluster ion beams for SIMS experiments opens new possibilities for molecular depth profiling and 3D chemical imaging. These beams generally leave less surface chemical damage and yield mass spectra with reduced fragmentation compared with smaller cluster projectiles. For nanoscale bioimaging applications, however, limited sensitivity due to low ionization probability and technical challenges of beam focusing remain problematic. The use of gas cluster ion beams based upon systems other than argon offer an opportunity to resolve these difficulties. Here we report on the prospects of employing CO2 as a simple alternative to argon. Ionization efficiency, chemical damage, sputter rate, and beam focus are investigated on model compounds using a series of CO2 and Ar cluster projectiles (cluster size 1000-5000) with the same mass. The results show that the two projectiles are very similar in each of these aspects. Computer simulations comparing the impact of Ar2000 and (CO2)2000 on an organic target also confirm that the CO2 molecules in the cluster projectile remain intact, acting as a single particle of m/z 44. The imaging resolution employing CO2 cluster projectiles is improved by more than a factor of two. The advantage of CO2 versus Ar is also related to the increased stability which, in addition, facilitates the operation of the gas cluster ion beams (GCIB) system at lower backing pressure.
Quantitative operando visualization of the energy band depth profile in solar cells.
Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei
2015-07-13
The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference.
Quantitative operando visualization of the energy band depth profile in solar cells
Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei
2015-01-01
The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference. PMID:26166580
Focks, D A; McLaughlin, R E; Smith, B M
1988-09-01
During the past decade, the rice agroecosystem and its associated mosquitoes have been the subject of an extensive research effort directed toward the development and implementation of integrated pest management (IPM) strategies. The objective of this work was to synthesize the literature and unpublished data on the rice agroecosystem into a comprehensive simulation model of the key elements of the system known to influence the population dynamics of Psorophora columbiae. Subsequent companion papers will present a validation of these models, provide an in-depth analysis of the population dynamics of Ps. columbiae, and evaluate current and proposed IPM strategies for this mosquito. This paper describes the development of 2 models: WaterMod: Because spatial and temporal distributions of surface water and soil moisture play a decisive role in the dynamics of Ps. columbiae, an essentially hydrological simulator was developed. Its purpose is to provide environmental inputs for a second model (PcSim) which simulates the population dynamics of Ps. columbiae. WaterMod utilizes data on weather, agricultural practices, and soil characteristics for a particular region to generate a data set containing daily estimates of soil moisture and depth of water table for 12 representative areas comprising the rice agroecosystem. This model could be used to provide hydrologic inputs for additional simulation models of other riceland mosquito species. PcSim: This model simulates the population dynamics of Ps. columbiae by using the computer to maintain a daily accounting of the absolute number of mosquitoes within each daily age class for each life stage. The model creates estimates of the number of eggs, larvae, pupae, and adults for a representative l-ha area of a rice agroecosystem.
Nakano, Shusuke; Yokoyama, Yuta; Aoyagi, Satoka; Himi, Naoyuki; Fletcher, John S; Lockyer, Nicholas P; Henderson, Alex; Vickerman, John C
2016-06-08
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) provides detailed chemical structure information and high spatial resolution images. Therefore, ToF-SIMS is useful for studying biological phenomena such as ischemia. In this study, in order to evaluate cerebral microinfarction, the distribution of biomolecules generated by ischemia was measured with ToF-SIMS. ToF-SIMS data sets were analyzed by means of multivariate analysis for interpreting complex samples containing unknown information and to obtain biomolecular mapping indicated by fragment ions from the target biomolecules. Using conventional ToF-SIMS (primary ion source: Bi cluster ion), it is difficult to detect secondary ions beyond approximately 1000 u. Moreover, the intensity of secondary ions related to biomolecules is not always high enough for imaging because of low concentration even if the masses are lower than 1000 u. However, for the observation of biomolecular distributions in tissues, it is important to detect low amounts of biological molecules from a particular area of tissue. Rat brain tissue samples were measured with ToF-SIMS (J105, Ionoptika, Ltd., Chandlers Ford, UK), using a continuous beam of Ar clusters as a primary ion source. ToF-SIMS with Ar clusters efficiently detects secondary ions related to biomolecules and larger molecules. Molecules detected by ToF-SIMS were examined by analyzing ToF-SIMS data using multivariate analysis. Microspheres (45 μm diameter) were injected into the rat unilateral internal carotid artery (MS rat) to cause cerebral microinfarction. The rat brain was sliced and then measured with ToF-SIMS. The brain samples of a normal rat and the MS rat were examined to find specific secondary ions related to important biomolecules, and then the difference between them was investigated. Finally, specific secondary ions were found around vessels incorporating microspheres in the MS rat. The results suggest that important biomolecules related to cerebral microinfarction can be detected by ToF-SIMS.
Kamann, Tjerk C; de Wit, Matty A S; Cremer, Stephan; Beekman, Aartjan T F
2014-02-20
To aid public health policy in preventing severe social exclusion (like homelessness) and promoting social inclusion (like labour market participation), we aimed to quantify (unmet) health needs of an expectedly vulnerable population on which little was known about: single male welfare recipients (SIM-welfare). One of the main policy questions was: is there need to promote access to healthcare for this specific group? A cross-sectional study incorporating peer-to-peer methodology to approach and survey SIM-welfare. Sociodemographics, prevalence of ill health, harmful drug use and healthcare utilisation for subgroups of SIM-welfare assessed with a different distance to the labour market and exposed to different reintegration policy were described and compared against single employed men (SIM-work). Men between the age of 23 and 64, living in single person households in Amsterdam. A random and representative sample of 472 SIM-welfare was surveyed during 2009-2010. A reference sample of 212 SIM-work was taken from the 2008 Amsterdam Health Survey. Standardised instruments were used to assess self-reported ill somatic and mental health, harmful drug use and service use. SIM-welfare are mostly long-term jobless, low educated, older men; 70% are excluded from re-employment policy due to multiple personal barriers. Health: 50% anxiety and depression; 47% harmful drug use; 41% multiple somatic illnesses. Health differences compared with SIM-work: (1) controlled for background characteristics, SIM-welfare report more mental (OR 4.0; 95% CI 2.1 to 4.7) and somatic illnesses (OR 3.1; 95% CI 2.7 to 6.0); (2) SIM-welfare assessed with the largest distance to the labour market report most combined health problems. Controlled for ill health, SIM-welfare are more likely to have service contacts than SIM-work. SIM-welfare form a selection of men with disadvantaged human capital and health. Findings do not support a need to improve access to healthcare. The stratification of welfare clients distinguishes between health needs.
Kamann, Tjerk C; de Wit, Matty A S; Cremer, Stephan; Beekman, Aartjan T F
2014-01-01
Objectives To aid public health policy in preventing severe social exclusion (like homelessness) and promoting social inclusion (like labour market participation), we aimed to quantify (unmet) health needs of an expectedly vulnerable population on which little was known about: single male welfare recipients (SIM-welfare). One of the main policy questions was: is there need to promote access to healthcare for this specific group? Design A cross-sectional study incorporating peer-to-peer methodology to approach and survey SIM-welfare. Sociodemographics, prevalence of ill health, harmful drug use and healthcare utilisation for subgroups of SIM-welfare assessed with a different distance to the labour market and exposed to different reintegration policy were described and compared against single employed men (SIM-work). Setting Men between the age of 23 and 64, living in single person households in Amsterdam. Participants A random and representative sample of 472 SIM-welfare was surveyed during 2009–2010. A reference sample of 212 SIM-work was taken from the 2008 Amsterdam Health Survey. Outcome measures Standardised instruments were used to assess self-reported ill somatic and mental health, harmful drug use and service use. Results SIM-welfare are mostly long-term jobless, low educated, older men; 70% are excluded from re-employment policy due to multiple personal barriers. Health: 50% anxiety and depression; 47% harmful drug use; 41% multiple somatic illnesses. Health differences compared with SIM-work: (1) controlled for background characteristics, SIM-welfare report more mental (OR 4.0; 95% CI 2.1 to 4.7) and somatic illnesses (OR 3.1; 95% CI 2.7 to 6.0); (2) SIM-welfare assessed with the largest distance to the labour market report most combined health problems. Controlled for ill health, SIM-welfare are more likely to have service contacts than SIM-work. Conclusions SIM-welfare form a selection of men with disadvantaged human capital and health. Findings do not support a need to improve access to healthcare. The stratification of welfare clients distinguishes between health needs. PMID:24556242
NASA Astrophysics Data System (ADS)
Chandra, Subhash
2008-12-01
Secondary ion mass spectrometry (SIMS) based imaging techniques capable of subcellular resolution characterization of elements and molecules are becoming valuable tools in many areas of biology and medicine. Due to high vacuum requirements of SIMS, the live cells cannot be analyzed directly in the instrument. The sample preparation, therefore, plays a critical role in preserving the native chemical composition for SIMS analysis. This work focuses on the evaluation of frozen-hydrated and frozen freeze-dried sample preparations for SIMS studies of cultured cells with a CAMECA IMS-3f dynamic SIMS ion microscope instrument capable of producing SIMS images with a spatial resolution of 500 nm. The sandwich freeze-fracture method was used for fracturing the cells. The complimentary fracture planes in the plasma membrane were characterized by field-emission secondary electron microscopy (FESEM) in the frozen-hydrated state. The cells fractured at the dorsal surface were used for SIMS analysis. The frozen-hydrated SIMS analysis of individual cells under dynamic primary ion beam (O 2+) revealed local secondary ion signal enhancements correlated with the water image signals of 19(H 3O) +. A preferential removal of water from the frozen cell matrix in the Z-axis was also observed. These complications render the frozen-hydrated sample type less desirable for subcellular dynamic SIMS studies. The freeze-drying of frozen-hydrated cells, either inside the instrument or externally in a freeze-drier, allowed SIMS imaging of subcellular chemical composition. Morphological evaluations of fractured freeze-dried cells with SEM and confocal laser scanning microscopy (CLSM) revealed well-preserved mitochondria, Golgi apparatus, and stress fibers. SIMS analysis of fractured freeze-dried cells revealed well-preserved chemical composition of even the most highly diffusible ions like K + and Na + in physiologically relevant concentrations. The high K-low Na signature in individual cells provided a rule-of-thumb criterion for the validation of sample preparation. The fractured freeze-dried cells allowed 3-D SIMS imaging and localization of 13C 15N labeled molecules and therapeutic drugs containing an elemental tag. Examples are shown to demonstrate that both diffusible elements and molecules are prone to artifact-induced relocation at subcellular scale if the sample preparation is compromised. The sample preparation is problem dependent and may vary widely between the diverse sample types of biological systems and the type of instrument used for SIMS analysis. The sample preparation, however, must be validated so that SIMS can be applied with confidence in biology and medicine.
Gold diffusion in mercury cadmium telluride grown by molecular beam epitaxy
NASA Astrophysics Data System (ADS)
Selamet, Yusuf; Singh, Rasdip; Zhao, Jun; Zhou, Yong D.; Sivananthan, Sivalingam; Dhar, Nibir K.
2003-12-01
The growth and characterization of Au-doped HgCdTe layers on (211)B CdTe/Si substrates grown by molecular beam epitaxy reported. The electrical properties of these layers studied for diffusion are presented. For ex-situ experiments, thin Au layers were deposited by evaporation and annealed at various temperatures and times to investigate the p-type doping properties and diffusion of Au in HgCdTe. The atomic distribution of the diffused Au was determined by secondary ion mass spectroscopy. We found clear evidence for p-type doping of HgCdTe:Au by in-situ and ex-situ methods. For in-situ doped layers, we found that, the Au cell temperature needs to be around 900°C to get p-type behavior. The diffusion coefficient of Au in HgCdTe was calculated by fitting SIMS profiles after annealing. Both complementary error functions and gaussian fittings were used, and were in full agreement. Diffusion coefficient as low as 8x10-14cm2/s observed for a sample annealed at 250°C and slow component of a diffusion coefficient as low as 2x10-15 cm2/s observed for a sample annealed at 300°C. Our preliminary results indicate no appreciable diffusion of Au in HgCdTe under the conditions used in these studies. Further work is in progress to confirm these results and to quantify our SIMS profiles.
Genetic Algorithm for Opto-thermal Skin Hydration Depth Profiling Measurements
NASA Astrophysics Data System (ADS)
Cui, Y.; Xiao, Perry; Imhof, R. E.
2013-09-01
Stratum corneum is the outermost skin layer, and the water content in stratum corneum plays a key role in skin cosmetic properties as well as skin barrier functions. However, to measure the water content, especially the water concentration depth profile, within stratum corneum is very difficult. Opto-thermal emission radiometry, or OTTER, is a promising technique that can be used for such measurements. In this paper, a study on stratum corneum hydration depth profiling by using a genetic algorithm (GA) is presented. The pros and cons of a GA compared against other inverse algorithms such as neural networks, maximum entropy, conjugate gradient, and singular value decomposition will be discussed first. Then, it will be shown how to use existing knowledge to optimize a GA for analyzing the opto-thermal signals. Finally, these latest GA results on hydration depth profiling of stratum corneum under different conditions, as well as on the penetration profiles of externally applied solvents, will be shown.
NASA Astrophysics Data System (ADS)
Bacon, C. R.
2007-12-01
In the ten years since publication of M. Reid et al.'s seminal paper on zircon ages from rhyolites (EPSL 150:2-39, 1997) >20 papers have appeared on SIMS 238U-230Th and 238U-206Pb geochronology of zircon from silicic volcanic rocks, plutonic xenoliths, and young intrusions. In some cases, as well as for U-Pb studies of Tertiary granitoids, plutonic samples are interpreted in the context of related volcanism. These geochronologic data have advanced conceptual models of silicic magma genesis and pluton construction. Of fundamental importance are discoveries that zircons in volcanic rocks typically pre-date eruption by 10's to 100's of kyr and that multiple zircon populations are common; these crystals are "antecrysts" recycled from intrusive rocks or crystal mush of the system that vented. Resolving such age differences is possible with U-Th at <300 ka but is challenging with U-Pb, where SIMS precision limits resolution of differences on the order of 100 kyr for Pleistocene-Miocene zircons. Cathodoluminescence (CL) imaging of polished crystals guides beam placement but leads to sampling bias that favors high-U regions. Thus, although model-age histograms and relative probability plots identify zircon age populations, they are unlikely to accurately define relative abundances of age groups. Microbeam analysis collects data for the entire volume sampled but only SIMS depth-profiling into crystal faces can spatially resolve fine zones. ID-TIMS analysis of CL-imaged zircon fragments can improve U-Pb precision. SIMS complements geochronology with trace element fingerprints of zircon growth environments and enables Ti-in-zircon thermometry. Literature examples illustrate recent findings: (1) rhyodacite lava at Crater Lake contains zircons derived from late Pleistocene granodiorite represented by blocks ejected in the caldera-forming eruption; (2) zircons in Mount St. Helens dacites grew at sub-eruption temperatures and pre-date eruptions by up to 250 kyr; (3) Miocene plutons near Mount Rainier and the Colorado River were emplaced and crystallized in pulses over ~2-3-Myr periods, some with coeval volcanics; and (4) Cretaceous batholiths in the Sierra Nevada and North Cascades preserve evidence of assembly over as much as 10 Myr; individual samples contain zircons that crystallized during intervals of >1 Myr. Zircon ages and wide-ranging trace element concentrations suggest crystallization mainly in differentiated melt pockets in high-crystallinity magmas that may repeatedly freeze and thaw. Some high-Th/U, incompatible-element rich, spongy textured zircons grew very late, in the presence of oxidizing fluid. Not all zircons survive recycling into undersaturated magmas, in which zircon will dissolve given enough time, depending on temperature and dissolved volatiles. Recent zircon geochronologic results for volcanic and plutonic rocks lend credence to the "mush model" of rhyolite genesis and batholith consolidation. Crystal-poor rhyolites and leucogranites are melts segregated by compaction or gas-driven filter pressing from granitoid crystal mush emplaced incrementally in the middle to upper crust and powered by basaltic magma repeatedly injected into the lower reaches of the mush column. Balance between heat loss and basaltic influx determines whether the mush freezes or partially thaws at any given time, blurs internal contacts in resulting plutons, and can produce large volumes of crystal-rich ignimbrite or rapid separation and eruption of crystal-poor rhyolite. Lifetimes of the largest volcano-plutonic systems, such as the Altiplano-Puna or Southern Rocky Mountains volcanic fields, are comparable to the ~10 Myr of the Tuolumne Intrusive Suite.
Wang, Y. M.; Xu, X. Q.; Yan, Z.; ...
2018-01-05
A six-field two-fluid model has been used to simulate density fluctuations. The equilibrium is generated by experimental measurements for both Deuterium (D) and Hydrogen (H) plasmas at the lowest densities of DIII-D low to high confinement (L-H) transition experiments. In linear simulations, the unstable modes are found to be resistive ballooning modes with the most unstable mode number n=30 ormore » $$k_\\theta\\rho_i\\sim0.12$$ . The ion diamagnetic drift and $$E\\times B$$ convection flow are balanced when the radial electric field (E r) is calculated from the pressure profile without net flow. The curvature drift plays an important role in this stage. Two poloidally counter propagating modes are found in the nonlinear simulation of the D plasma at electron density $$n_e\\sim1.5\\times10^{19}$$ m -3 near the separatrix while a single ion mode is found in the H plasma at the similar lower density, which are consistent with the experimental results measured by the beam emission spectroscopy (BES) diagnostic on the DIII-D tokamak. The frequency of the electron modes and the ion modes are about 40kHz and 10 kHz respectively. The poloidal wave number $$k_\\theta$$ is about 0.2 cm -1 ($$k_\\theta\\rho_i\\sim0.05$$ ) for both ion and electron modes. The particle flux, ion and electron heat fluxes are~3.5–6 times larger for the H plasma than the D plasma, which makes it harder to achieve H-mode for the same heating power. The change of the atomic mass number A from 2 to 1 using D plasma equilibrium make little difference on the flux. Increase the electric field will suppress the density fluctuation. In conclusion, the electric field scan and ion mass scan results show that the dual-mode results primarily from differences in the profiles rather than the ion mass.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Y. M.; Xu, X. Q.; Yan, Z.
A six-field two-fluid model has been used to simulate density fluctuations. The equilibrium is generated by experimental measurements for both Deuterium (D) and Hydrogen (H) plasmas at the lowest densities of DIII-D low to high confinement (L-H) transition experiments. In linear simulations, the unstable modes are found to be resistive ballooning modes with the most unstable mode number n=30 ormore » $$k_\\theta\\rho_i\\sim0.12$$ . The ion diamagnetic drift and $$E\\times B$$ convection flow are balanced when the radial electric field (E r) is calculated from the pressure profile without net flow. The curvature drift plays an important role in this stage. Two poloidally counter propagating modes are found in the nonlinear simulation of the D plasma at electron density $$n_e\\sim1.5\\times10^{19}$$ m -3 near the separatrix while a single ion mode is found in the H plasma at the similar lower density, which are consistent with the experimental results measured by the beam emission spectroscopy (BES) diagnostic on the DIII-D tokamak. The frequency of the electron modes and the ion modes are about 40kHz and 10 kHz respectively. The poloidal wave number $$k_\\theta$$ is about 0.2 cm -1 ($$k_\\theta\\rho_i\\sim0.05$$ ) for both ion and electron modes. The particle flux, ion and electron heat fluxes are~3.5–6 times larger for the H plasma than the D plasma, which makes it harder to achieve H-mode for the same heating power. The change of the atomic mass number A from 2 to 1 using D plasma equilibrium make little difference on the flux. Increase the electric field will suppress the density fluctuation. In conclusion, the electric field scan and ion mass scan results show that the dual-mode results primarily from differences in the profiles rather than the ion mass.« less
Water-in-Olivine Magma Ascent Chronometry: Every Crystal is a Clock
NASA Astrophysics Data System (ADS)
Newcombe, M. E.; Asimow, P. D.; Ferriss, E.; Barth, A.; Lloyd, A. S.; Hauri, E.; Plank, T. A.
2017-12-01
The syneruptive decompression rate of basaltic magma in volcanic conduits is thought to be a critical control on eruptive vigor. Recent efforts have constrained decompression rates using models of diffusive water loss from melt embayments (Lloyd et al. 2014; Ferguson et al. 2016), olivine-hosted melt inclusions (Chen et al. 2013; Le Voyer et al. 2014), and clinopyroxene phenocrysts (Lloyd et al. 2016). However, these techniques are difficult to apply because of the rarity of melt embayments and clinopyroxene phenocrysts suitable for analysis and the complexities associated with modeling water loss from melt inclusions. We are developing a new magma ascent chronometer based on syneruptive diffusive water loss from olivine phenocrysts. We have found water zonation in every olivine phenocryst we have measured, from explosive eruptions of Pavlof, Seguam, Fuego, Cerro Negro and Kilauea volcanoes. Phenocrysts were polished to expose a central plane normal to the crystallographic `b' axis and volatile concentration profiles were measured along `a' and `c' axes by SIMS or nanoSIMS. Profiles are compared to 1D and 3D finite-element models of diffusive water loss from olivine, with or without melt inclusions, whose boundaries are in equilibrium with a melt undergoing closed-system degassing. In every case, we observe faster water diffusion along the `a' axis, consistent with the diffusion anisotropy observed by Kohlstedt and Mackwell (1998) for the so-called `proton-polaron' mechanism of H-transport. Water concentration gradients along `a' match the 1D diffusion model with a diffusivity of 10-10 m2/s (see Plank et al., this meeting), olivine-melt partition coefficient of 0.0007-0.002 (based on melt inclusion-olivine pairs), and decompression rates equal to the best-fit values from melt embayment studies (Lloyd et al. 2014; Ferguson et al. 2016). Agreement between the melt embayment and water-in-olivine ascent chronometers at Fuego, Seguam, and Kilauea Iki demonstrates the potential of this new technique, which can be applied to any olivine-bearing mafic-intermediate eruption using common analytical tools (SIMS and FTIR). In theory, each crystal is a clock, with the potential to record variable ascent in the conduit, over the course of an eruption, and between eruptions.
Vimal Kumar, K G; Dinesh Kumar, P K; Smitha, B R; Habeeb Rahman, H; Josia, Jacob; Muraleedharan, K R; Sanjeevan, V N; Achuthankutty, C T
2008-05-01
Seasonal variation of the hydrography along the southeast Arabian Sea is described using data collected onboard FORV Sagar Sampada in September--October 2003 (later phase of Southwest monsoon, SWM) and March--April 2004 (Spring inter monsoon, SIM). During the later phase of the SWM, upwelling was in the withdrawal phase and the frontal structure was clearer in the northern sections (13 and 15 degrees N lat) indicating strong upwelling in the area. The driving force of upwelling is identified as the combination of alongshore wind stress and remote forcing with a latitudinal variability. Although a more prominent upwelling was found in the north, a maximum surface Chlorophyll-a was found in the south (10 degrees N). During the SIM, the area was characterized by oligotrophic water with relatively high Sea Surface Temperature (>29 degrees C) and low salinity (33.8 to 35.4). During March, the surface hydrography was found to be controlled mainly by the intrusion of low-saline waters from the south, while during September by the high saline water from the north. The presence of various water masses [Arabian Sea High Salinity Water (ASHSW), Persian Gulf Water (PGW), Red Sea Water (RSW)] and their seasonal variations in the region is discussed and their decreasing influence towards the south is noted during both periods of observation. During the SWM, the dynamic topography showed the equator-ward flow of the West India Coastal Current (WICC) at the surface and a pole-ward coastal under current at sub-thermocline depth. During the SIM, surface circulation revealed the WICC flowing pole-ward north of 13 degrees N, but equator-ward flow in the south, with a clockwise circulation around the Lakshadweep High.
NASA Astrophysics Data System (ADS)
Gabitov, R. I.; Carricart Ganivet, J. P.; Prieto, R. I.
2012-12-01
Our understanding of climate change and oceanographic variability through time is largely derived from knowledge of oxygen isotopes (δ18O) and elemental ratios (X/Ca) signatures in coral reefs. However, the existence of inconsistencies in isotopic composition between different coral specimens suggests that factors other than temperature and seawater composition affect isotopic and chemical records. We conducted in situ Secondary Ion Mass Spectrometry (SIMS) analyses on the reef building coral (Montastraea annularis) from Veracuz Reef in the southern Gulf of Mexico. Coral specimen was sliced in perpendicular and parallel directions of its growth. Therefore, one of the sections exposed simultaneously grown skeletal material; another section represents a time series of continuously extended skeleton. The complex microstructure of the coral yields a few morphologically different zones (architectural elements). There are theca-wall (Th), septa (S), costa (C), exothecal (ExD) and endothecal dissepiments (EnD). Dissepiments formation in Montastraea annularis is linked to moon cycles and there are 12 or 13 ExD formed per year; meanwhile, there are 24 or 26 EnD per year (Dávalos-Dehullu et al. 2008). SIMS analyses were performed on Th, S, C, ExD, and EnD at lateral spatial resolution of ~20 μm. SIMS spot profiles with 100 and 500 μm steps were conducted on Th wall in the direction of coral growth. SIMS analyses demontrate that δ18O in Th, S, C, and ExD that grown at the same time are similar to each other within 1 sigma error. However, δ18O in EnD is isotopically heavier by 1 ‰ than those of simultaneously grown T,S, and ExD. The reverse dependence of δ18O on growth rate of corals and inorganically precipitated aragonite was reported by previous works and potentially could explain the δ18O enrichment in EnD, which grow by 35% slower than ExD (McConnaughey 1989; Dávalos-Dehullu et al. 2008; Gabitov 2012). SIMS spot profiles in the coral growth direction yielded weekly time resolution and demonstrate that factors other than temperature affect elemental and isotopic ratios in corallite aragonite. δ18O positively correlates with Sr/Ca and B/Ca but opposite to Mg/Ca. δ18O-Sr/Ca relationship suggest that they are driven by temperature at least partially. Sr/Ca-Mg/Ca trend is agreed with Raleigh fractionation. Sr/Ca-B/Ca relationship suggests temperature effect on B/Ca. References McConnaughey (1989) 13C and 18O disequilibrium in biological carbonates: I. Patterns. Geochim. Cosmochim. Acta, 53, 151-162. Dávalos-Dehullu, E., Hernández-Arana H., and Carricart-Ganivet J.P. (2008) On the causes of density banding in skeletons of corals of the genus Montastraea. J. Exp. Mar. Biol. Ecol. 365, 142-147. Gabitov R.I. (2012) Growth rate effect on oxygen isotope fractionation between aragonite and fluid at 24°C by in situ analysis. Goldschmidt Conference, Montreal.
Roytman, Marina; Ramkissoon, Resham; Wu, Christina; Hong, Leena; Trujillo, Ruby; Huddleston, Leslie; Poerzgen, Peter; Seto, Todd; Wong, Linda; Tsai, Naoky
2017-01-01
Background/objectives The COSMOS study was a phase 2a clinical trial that showed high cure rates of genotype 1 chronic hepatitis C (CHC) and a favorable side effect profile using a 12-week regimen of simeprevir + sofosbuvir (SIM + SOF). Given the small number of patients treated with the SIM + SOF regimen in the COSMOS trial, there is uncertainty regarding the efficacy and safety of this combination therapy. We now report our experience with the COSMOS regimen in the multiethnic population of Hawaii, including patients of East Asian ancestry and with decompensated cirrhosis. Methods This study is a retrospective review of 138 patients treated with a fixed dose regimen of SIM 150 mg and SOF 400 mg daily at a single referral center. We collected data on demographics, side effects, laboratory studies and sustained virological response (SVR). Statistical analysis was performed with Stata v8.2 software. Results Baseline characteristics of the 138 patients initiated with SIM + SOF therapy were: 68.8 % cirrhotic (22.1 % of those Child-Pugh Class B), 37 % Asian, 11.6 % Pacific Islander, 63 % male, mean age 61.3 ± 7.8 years, mean BMI 27.8 ± 6.1 kg/m2, 26.8 % diabetic, 63.8 % genotype 1a, 44.9 % previously treatment experienced. A total of 100 % of patients that completed therapy (n = 137) had undetectable viral loads at end of treatment (EOT). Twelve patients relapsed post-treatment resulting in an overall 12 week SVR (SVR12) rate of 89.1 %. 95 % of decompensated cirrhotic patients achieved SVR12, compared to 85.3 % of compensated cirrhotic patients and 93 % of non-cirrhotic patients. 92 % of Asian patients achieved SVR12 compared to 87.5 % in non-Asian patients. There were no statistically significant differences in SVR12 between treatment naive and treatment experienced patients (86.8 vs 91.9 %). 87.5 % of post-transplant patients achieved SVR12. The main side effects were headache 16.2 %, fatigue 24.2 %, pruritis 14.1 %; none were >grade 2 in severity. There were no differences in side effect profiles of patients with decompensated cirrhosis. Pruritis only was statistically significant between Asians and non-Asians (22 vs 5.7 %). Trends toward improvement in platelet counts and total bilirubin were noted at 12-weeks post treatment, while improvement in albumin in cirrhotic patients reached statistical significance (3.77–4.01 mg/dL, p = 0.0108). Conclusions The 12-week fixed dose course of SIM + SOF was well tolerated in a multiethnic population of primarily cirrhotic patients, including those with decompensated disease. This real world trial achieved SVR12 rates comparable to the COSMOS data. Higher incidence of adverse side effects was not observed with an exception of higher rate of pruritis in Asians. The increase in albumin in cirrhotic patients was statistically significant and suggested early improvement in synthetic function following viral eradication. Higher BMI (≥30 kg/m2) was the only factor that correlated with post-treatment relapse by multivariate analysis. PMID:27026431
NASA Astrophysics Data System (ADS)
Shafer, J. T.; Neal, C. R.
2003-12-01
Picritic and high-MgO (7.7-24 wt.%) basalt samples from Detroit (/sim81-76 Ma) and Koko (/sim48 Ma) Seamounts along the ESC have been analyzed for PGEs (Ru, Rh, Pd, Ir, and Pt) allowing an examination of how the PGEs in lavas from the Hawaiian plume have changed over time. Major and trace element (including the PGEs) concentrations were quantified by ICP methods at the University of Notre Dame. See Ely et al. (1999, Chem. Geol. 157:219) for the PGE analytical method. Bennett et al. (2000) analyzed Hawaiian picrites and found PGE abundances slightly greater than average MORB and comparable to the low-PGE basaltic komatiites. These authors modeled the PGE abundances of these picrites by using variable amounts of residual sulfide during melting, such that Koolau (low PGE contents) formed from a relatively sulfide-rich source and Loihi (high PGEs) from a sulfide-poor source. Our PGE data from Detroit Seamount show slightly higher PGE abundances than Loihi and Kilauea, suggesting these picrites formed from a source lacking residual sulfide. These results suggest that, if the model of Bennett et al. (2000) is correct, the dilution of plume lava with MORB source, as hypothesized on the basis of depleted isotope ratios and lower trace element abundances than modern Hawaii (Keller et al., 2000, Nature 405:603; Kinman & Neal, 2002, Eos 83:F1282; Regelous et al., 2003, JPet 44:113), was not the controlling factor in PGE abundances. However, since MORB PGE concentrations are not substantially different than low-PGE Hawaiian picrites, incorporation of MORB material within the Hawaiian plume at Detroit Seamount would not have drastically reduced the PGE abundances. Koko Seamount has relatively high PGE concentrations (/sim3-12 times greater than those from Detroit lavas). This may be the result of a lack of residual sulfide facilitated by higher degrees of partial melting. Although our initial data are consistent with variable degrees of partial melting and/or source heterogeneity over the life of the Hawaiian plume, the data from Detroit Seamount can be modeled by, for example, magma mixing between Koko-type "PGE-rich" plume and MORB end members (cf. Kinman & Neal, 2002). The Pt/Ir ratios and PGE abundances of picrites from Detroit and Koko Seamounts and from Hawaii (as analyzed by Bennett et al., 2000) increase in the order: Hawaii (4.8), Detroit (5.8), Koko (8.1). Bennett et al. argued that if more sulfide was retained in the source the PGE profile would be more fractionated and abundances would be lower. Our data suggest the opposite is true. For Koko Seamount to have PGE abundances approximately 3-12 times greater than the high-PGE picrites from Hawaii and yet have a more fractionated profile, the source of the Hawaiian plume must have been relatively PGE-enriched at 48 Ma than it is currently. In addition, the more fractionated profile of Detroit Seamount is consistent with the incorporation of MORB material (Pt/Ir /sim 25.9), thereby raising its Pt/Ir ratio.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2017-11-06
ImagingSIMS is an open source application for loading, processing, manipulating and visualizing secondary ion mass spectrometry (SIMS) data. At PNNL, a separate branch has been further developed to incorporate application specific features for dynamic SIMS data sets. These include loading CAMECA IMS-1280, NanoSIMS and modified IMS-4f raw data, creating isotopic ratio images and stitching together images from adjacent interrogation regions. In addition to other modifications of the parent open source version, this version is equipped with a point-by-point image registration tool to assist with streamlining the image fusion process.
Rapid characterisation of surface modifications and treatments using a benchtop SIMS instrument
NASA Astrophysics Data System (ADS)
McPhail, D. S.; Sokhan, M.; Rees, E. E.; Cliff, B.; Eccles, A. J.; Chater, R. J.
2004-06-01
The development of a novel benchtop SIMS instrument (Millbrook MiniSIMS) [Appl. Surf. Sci. 144 (1999) 106] has brought routine SIMS analysis to many new users, for example museum conservators. This is a result of the simple operation and the relatively low capital cost of the instrument. We report here on the continued development of the system in terms of increasing performance and functionality and its use in museum conservation based applications where a mobile instrument for high throughput, rapid SIMS analysis has proven to be of great benefit to the user. The example we describe here is the application of the MiniSIMS to the analysis of silver thread woven into a silk dress before and after laser cleaning.
Development of a TOF SIMS setup at the Zagreb heavy ion microbeam facility
NASA Astrophysics Data System (ADS)
Tadić, Tonči; Bogdanović Radović, Iva; Siketić, Zdravko; Cosic, Donny Domagoj; Skukan, Natko; Jakšić, Milko; Matsuo, Jiro
2014-08-01
We describe a new Time-of-flight Secondary Ion Mass Spectrometry (TOF SIMS) setup for MeV SIMS application, which is constructed and installed at the heavy ion microbeam facility at the Ruđer Bošković Institute in Zagreb. The TOF-SIMS setup is developed for high sensitivity molecular imaging using a heavy ion microbeam that focuses ion beams (from C to I) with sub-micron resolution. Dedicated pulse processing electronics for MeV SIMS application have been developed, enabling microbeam-scanning control, incoming ion microbeam pulsing and molecular mapping. The first results showing measured MeV SIMS spectra as well as molecular maps for samples of interest are presented and discussed.
California State Waters Map Series Data Catalog
Golden, Nadine E.
2013-01-01
In 2007, the California Ocean Protection Council initiated the California Seafloor Mapping Program (CSMP), designed to create a comprehensive seafloor map of high-resolution bathymetry, marine benthic habitats, and geology within the 3-nautical-mile limit of California's State Waters. The CSMP approach is to create highly detailed seafloor maps and associated data layers through the collection, integration, interpretation, and visualization of swath sonar data, acoustic backscatter, seafloor video, seafloor photography, high-resolution seismic-reflection profiles, and bottom-sediment sampling data. CSMP has divided coastal California into 110 map blocks (fig. 1), each to be published individually as USGS Scientific Investigations Maps (SIMs) at a scale of 1:24,000. The map products display seafloor morphology and character, identify potential marine benthic habitats, and illustrate both the seafloor geology and shallow (to about 100 m) subsurface geology. This CSMP data catalog contains much of the data used to prepare the SIMs in the California State Waters Map Series. Other data that were used to prepare the maps were compiled from previously published sources (for example, onshore geology) and, thus, are not included herein.
Meteoric 10Be in soil profiles - A global meta-analysis
Graly, Joseph A.; Bierman, Paul R.; Reusser, Lucas J.; Pavich, Milan J.
2010-01-01
In order to assess current understanding of meteoric 10Be dynamics and distribution in terrestrial soils, we assembled a database of all published meteoric 10Be soil depth profiles, including 104 profiles from 27 studies in globally diverse locations, collectively containing 679 individual measurements. This allows for the systematic comparison of meteoric 10Be concentration to other soil characteristics and the comparison of profile depth distributions between geologic settings. Percent clay, 9Be, and dithionite-citrate extracted Al positively correlate to meteoric 10Be in more than half of the soils where they were measured, but the lack of significant correlation in other soils suggests that no one soil factor controls meteoric 10Be distribution with depth. Dithionite-citrate extracted Fe and cation exchange capacity are only weakly correlated to meteoric 10Be. Percent organic carbon and pH are not significantly related to meteoric 10Be concentration when all data are complied.The compilation shows that meteoric 10Be concentration is seldom uniform with depth in a soil profile. In young or rapidly eroding soils, maximum meteoric 10Be concentrations are typically found in the uppermost 20 cm. In older, more slowly eroding soils, the highest meteoric 10Be concentrations are found at depth, usually between 50 and 200 cm. We find that the highest measured meteoric 10Be concentration in a soil profile is an important metric, as both the value and the depth of the maximum meteoric 10Be concentration correlate with the total measured meteoric 10Be inventory of the soil profile.In order to refine the use of meteoric 10Be as an estimator of soil erosion rate, we compare near-surface meteoric 10Be concentrations to total meteoric 10Be soil inventories. These trends are used to calibrate models of meteoric 10Be loss by soil erosion. Erosion rates calculated using this method vary based on the assumed depth and timing of erosional events and on the reference data selected.
Breadth and Depth of Vocabulary Knowledge and Their Effects on L2 Vocabulary Profiles
ERIC Educational Resources Information Center
Bardakçi, Mehmet
2016-01-01
Breadth and depth of vocabulary knowledge have been studied from many different perspectives, but the related literature lacks serious studies dealing with their effects on vocabulary profiles of EFL learners. In this paper, with an aim to fill this gap, the relative effects of breadth and depth of vocabulary knowledge on L2 vocabulary profiles…
NASA Technical Reports Server (NTRS)
Holmes, Thomas; Owe, Manfred; deJeu, Richard
2007-01-01
Two data sets of experimental field observations with a range of meteorological conditions are used to investigate the possibility of modeling near-surface soil temperature profiles in a bare soil. It is shown that commonly used heat flow methods that assume a constant ground heat flux can not be used to model the extreme variations in temperature that occur near the surface. This paper proposes a simple approach for modeling the surface soil temperature profiles from a single depth observation. This approach consists of two parts: 1) modeling an instantaneous ground flux profile based on net radiation and the ground heat flux at 5cm depth; 2) using this ground heat flux profile to extrapolate a single temperature observation to a continuous near surface temperature profile. The new model is validated with an independent data set from a different soil and under a range of meteorological conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-06-01
WEC-Sim is a DOE-funded software tool being jointly developed by NREL and SNL. WEC-Sim computationally models wave energy converters (WEC), devices that generate electricity using movement of water systems such as oceans, rivers, etc. There is great potential for WECs to generate electricity, but as of yet, the industry has yet to establish a commercially viable concept. Modeling, design, and simulations tools are essential to the successful development of WECs. Commercial WEC modeling software tools can't be modified by the user. In contrast, WEC-Sim is a free, open-source, and flexible enough to be modified to meet the rapidly evolving needsmore » of the WEC industry. By modeling the power generation performance and dynamic loads of WEC designs, WEC-Sim can help support the development of new WEC devices by optimizing designs for cost of energy and competitiveness. By being easily accessible, WEC-Sim promises to help level the playing field in the WEC industry. Importantly, WEC-Sim is also excellent at its job! In 2014, WEC-Sim was used in conjunction with NREL’s FAST modeling software to win a hydrodynamic modeling competition. WEC-Sim and FAST performed very well at predicting the motion of a test device in comparison to other modeling tools. The most recent version of WEC-Sim (v1.1) was released in April 2015.« less
Binding properties of SUMO-interacting motifs (SIMs) in yeast.
Jardin, Christophe; Horn, Anselm H C; Sticht, Heinrich
2015-03-01
Small ubiquitin-like modifier (SUMO) conjugation and interaction play an essential role in many cellular processes. A large number of yeast proteins is known to interact non-covalently with SUMO via short SUMO-interacting motifs (SIMs), but the structural details of this interaction are yet poorly characterized. In the present work, sequence analysis of a large dataset of 148 yeast SIMs revealed the existence of a hydrophobic core binding motif and a preference for acidic residues either within or adjacent to the core motif. Thus the sequence properties of yeast SIMs are highly similar to those described for human. Molecular dynamics simulations were performed to investigate the binding preferences for four representative SIM peptides differing in the number and distribution of acidic residues. Furthermore, the relative stability of two previously observed alternative binding orientations (parallel, antiparallel) was assessed. For all SIMs investigated, the antiparallel binding mode remained stable in the simulations and the SIMs were tightly bound via their hydrophobic core residues supplemented by polar interactions of the acidic residues. In contrary, the stability of the parallel binding mode is more dependent on the sequence features of the SIM motif like the number and position of acidic residues or the presence of additional adjacent interaction motifs. This information should be helpful to enhance the prediction of SIMs and their binding properties in different organisms to facilitate the reconstruction of the SUMO interactome.
Biochemical imaging of tissues by SIMS for biomedical applications
NASA Astrophysics Data System (ADS)
Lee, Tae Geol; Park, Ji-Won; Shon, Hyun Kyong; Moon, Dae Won; Choi, Won Woo; Li, Kapsok; Chung, Jin Ho
2008-12-01
With the development of optimal surface cleaning techniques by cluster ion beam sputtering, certain applications of SIMS for analyzing cells and tissues have been actively investigated. For this report, we collaborated with bio-medical scientists to study bio-SIMS analyses of skin and cancer tissues for biomedical diagnostics. We pay close attention to the setting up of a routine procedure for preparing tissue specimens and treating the surface before obtaining the bio-SIMS data. Bio-SIMS was used to study two biosystems, skin tissues for understanding the effects of photoaging and colon cancer tissues for insight into the development of new cancer diagnostics for cancer. Time-of-flight SIMS imaging measurements were taken after surface cleaning with cluster ion bombardment by Bi n or C 60 under varying conditions. The imaging capability of bio-SIMS with a spatial resolution of a few microns combined with principal component analysis reveal biologically meaningful information, but the lack of high molecular weight peaks even with cluster ion bombardment was a problem. This, among other problems, shows that discourse with biologists and medical doctors are critical to glean any meaningful information from SIMS mass spectrometric and imaging data. For SIMS to be accepted as a routine, daily analysis tool in biomedical laboratories, various practical sample handling methodology such as surface matrix treatment, including nano-metal particles and metal coating, in addition to cluster sputtering, should be studied.
Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner
NASA Astrophysics Data System (ADS)
Poon, Jonathan K.; Dahlbom, Magnus L.; Casey, Michael E.; Qi, Jinyi; Cherry, Simon R.; Badawi, Ramsey D.
2015-02-01
Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.
SimPhy: Phylogenomic Simulation of Gene, Locus, and Species Trees
Mallo, Diego; De Oliveira Martins, Leonardo; Posada, David
2016-01-01
We present a fast and flexible software package—SimPhy—for the simulation of multiple gene families evolving under incomplete lineage sorting, gene duplication and loss, horizontal gene transfer—all three potentially leading to species tree/gene tree discordance—and gene conversion. SimPhy implements a hierarchical phylogenetic model in which the evolution of species, locus, and gene trees is governed by global and local parameters (e.g., genome-wide, species-specific, locus-specific), that can be fixed or be sampled from a priori statistical distributions. SimPhy also incorporates comprehensive models of substitution rate variation among lineages (uncorrelated relaxed clocks) and the capability of simulating partitioned nucleotide, codon, and protein multilocus sequence alignments under a plethora of substitution models using the program INDELible. We validate SimPhy's output using theoretical expectations and other programs, and show that it scales extremely well with complex models and/or large trees, being an order of magnitude faster than the most similar program (DLCoal-Sim). In addition, we demonstrate how SimPhy can be useful to understand interactions among different evolutionary processes, conducting a simulation study to characterize the systematic overestimation of the duplication time when using standard reconciliation methods. SimPhy is available at https://github.com/adamallo/SimPhy, where users can find the source code, precompiled executables, a detailed manual and example cases. PMID:26526427
Aaboud, M.; Aad, G.; Abbott, B.; ...
2017-12-15
A search for pair production of a scalar partner of the top quark in events with four or more jets plus missing transverse momentum is presented. Here, an analysis of 36.1 fb -1 ofmore » $$ \\sqrt{s}=13 $$ TeV proton-proton collisions collected using the ATLAS detector at the LHC yields no significant excess over the expected Standard Model background. To interpret the results a simplified supersymmetric model is used where the top squark is assumed to decay via $$\\sim\\atop{t}$$ 1→t(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$ and $$\\sim\\atop{t}$$ 1→b$$\\sim\\atop{χ}$$ $$±\\atop{1}$$→bW(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, where χ 1 0 (χ 1 ± ) denotes the lightest neutralino (chargino). Exclusion limits are placed in terms of the top-squark and neutralino masses. Assuming a branching ratio of 100% to t$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, top-squark masses in the range 450–1000 GeV are excluded for $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ masses below 160 GeV. In the case where m$$\\sim\\atop{t}$$ 1-m t+m $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ , top-squark masses in the range 235–590 GeV are excluded.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaboud, M.; Aad, G.; Abbott, B.
A search for pair production of a scalar partner of the top quark in events with four or more jets plus missing transverse momentum is presented. Here, an analysis of 36.1 fb -1 ofmore » $$ \\sqrt{s}=13 $$ TeV proton-proton collisions collected using the ATLAS detector at the LHC yields no significant excess over the expected Standard Model background. To interpret the results a simplified supersymmetric model is used where the top squark is assumed to decay via $$\\sim\\atop{t}$$ 1→t(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$ and $$\\sim\\atop{t}$$ 1→b$$\\sim\\atop{χ}$$ $$±\\atop{1}$$→bW(*)$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, where χ 1 0 (χ 1 ± ) denotes the lightest neutralino (chargino). Exclusion limits are placed in terms of the top-squark and neutralino masses. Assuming a branching ratio of 100% to t$$\\sim\\atop{χ}$$ $$0\\atop{1}$$, top-squark masses in the range 450–1000 GeV are excluded for $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ masses below 160 GeV. In the case where m$$\\sim\\atop{t}$$ 1-m t+m $$\\sim\\atop{χ}$$ $$0\\atop{1}$$ , top-squark masses in the range 235–590 GeV are excluded.« less
XPS investigation of depth profiling induced chemistry
NASA Astrophysics Data System (ADS)
Pratt, Quinn; Skinner, Charles; Koel, Bruce; Chen, Zhu
2017-10-01
Surface analysis is an important tool for understanding plasma-material interactions. Depth profiles are typically generated by etching with a monatomic argon ion beam, however this can induce unintended chemical changes in the sample. Tantalum pentoxide, a sputtering standard, and PEDOT:PSS, a polymer that was used to mimic the response of amorphous carbon-hydrogen co-deposits, were studied. We compare depth profiles generated with monatomic and gas cluster argon ion beams (GCIB) using X-ray photoelectron spectroscopy (XPS) to quantify chemical changes. In both samples, monatomic ion bombardment led to beam-induced chemical changes. Tantalum pentoxide exhibited preferential sputtering of oxygen and the polymer experienced significant bond modification. Depth profiling with clusters is shown to mitigate these effects. We present sputtering rates for Ta2O5 and PEDOT:PSS as a function of incident energy and flux. Support was provided through DOE Contract Number DE-AC02-09CH11466.
Static Time-of-Flight Secondary Ion Mass Spectrometry (SIMS) | Materials
-Flight Secondary Ion Mass Spectrometry (SIMS) Image of high mass resolution and mass accuracy provided by TOF SIMS We used the high mass resolution and mass accuracy of TOF SIMS to study surface cleanliness acidic wash resulted in contamination by Fe and other metals. Without high mass accuracy, the CaO signal
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
....; Blanchester Plant, Including On-Site Leased Workers From Adecco and Sims Bros., Inc.; Blanchester, OH; Amended... workers from Sims Bros., Inc. were working on-site at the subject firm during the relevant period and that the services supplied by Sims Bros., Inc. were related to the production of gear boxes (and parts...
Teaching the Teacher: Tutoring SimStudent Leads to More Effective Cognitive Tutor Authoring
ERIC Educational Resources Information Center
Matsuda, Noboru; Cohen, William W.; Koedinger, Kenneth R.
2015-01-01
SimStudent is a machine-learning agent initially developed to help novice authors to create cognitive tutors without heavy programming. Integrated into an existing suite of software tools called Cognitive Tutor Authoring Tools (CTAT), SimStudent helps authors to create an expert model for a cognitive tutor by tutoring SimStudent on how to solve…
NASA Astrophysics Data System (ADS)
Tardani, Daniele; Reich, Martin; Deditius, Artur P.; Chryssoulis, Stephen; Sánchez-Alfaro, Pablo; Wrage, Jackie; Roberts, Malcolm P.
2017-05-01
Over the past few decades several studies have reported that pyrite hosts appreciable amounts of trace elements which commonly occur forming complex zoning patterns within a single mineral grain. These chemical zonations in pyrite have been recognized in a variety of hydrothermal ore deposit types (e.g., porphyry Cu-Mo-Au, epithermal Au deposits, iron oxide-copper-gold, Carlin-type and Archean lode Au deposits, among others), showing, in some cases, marked oscillatory alternation of metals and metalloids in pyrite growth zones (e.g., of Cu-rich, As-(Au, Ag)-depleted zones and As-(Au, Ag)-rich, Cu-depleted zones). This decoupled geochemical behavior of Cu and As has been interpreted as a result of chemical changes in ore-forming fluids, although direct evidence connecting fluctuations in hydrothermal fluid composition with metal partitioning into pyrite growth zones is still lacking. In this study, we report a comprehensive trace element database of pyrite from the Tolhuaca Geothermal System (TGS) in southern Chile, a young and active hydrothermal system where fewer pyrite growth rims and mineralization events are present and the reservoir fluid (i.e. ore-forming fluid) is accessible. We combined the high-spatial resolution and X-ray mapping capabilities of electron microprobe analysis (EMPA) with low detection limits and depth-profiling capacity of secondary-ion mass spectrometry (SIMS) in a suite of pyrite samples retrieved from a ∼1 km drill hole that crosses the argillic (20-450 m) and propylitic (650-1000 m) alteration zones of the geothermal system. We show that the concentrations of precious metals (e.g., Au, Ag), metalloids (e.g., As, Sb, Se, Te), and base and heavy metals (e.g., Cu, Co, Ni, Pb) in pyrite at the TGS are significant. Among the elements analyzed, As and Cu are the most abundant with concentrations that vary from sub-ppm levels to a few wt.% (i.e., up to ∼5 wt.% As, ∼1.5 wt.% Cu). Detailed wavelength-dispersive spectrometry (WDS) X-ray maps and SIMS depth vs. isotope concentration profiles reveal that pyrites from the TGS are characterized by chemical zoning where the studied elements occur in different mineralogical forms. Arsenic and Co occur as structurally bound elements in pyrite, Cu and Au in pyrite can occur as both solid solution and submicron-sized particles of chalcopyrite and native Au (or Au tellurides), respectively. Pyrites from the deeper propylitic zone do not show significant zonation and high Cu-(Co)-As concentrations correlate with each other. In contrast, well-developed zonations were detected in pyrite from the shallow argillic alteration zone, where Cu(Co)-rich, As-depleted cores alternate with Cu(Co)-depleted, As-rich rims. These microanalytical data were contrasted with chemical data of fluid inclusions in quartz and calcite veins (high Cu/As ratios) and borehole fluid (low Cu/As ratios) reported at the TGS, showing a clear correspondence between Cu and As concentrations in pyrite-forming fluids and chemical zonation in pyrite. These observations provide direct evidence supporting the selective partitioning of metals into pyrite as a result of changes in ore-forming fluid composition, most likely due to separation of a single-phase fluid into a low-density vapor and a denser brine, capable of fractionating Cu and As.
SimGraph: A Flight Simulation Data Visualization Workstation
NASA Technical Reports Server (NTRS)
Kaplan, Joseph A.; Kenney, Patrick S.
1997-01-01
Today's modern flight simulation research produces vast amounts of time sensitive data, making a qualitative analysis of the data difficult while it remains in a numerical representation. Therefore, a method of merging related data together and presenting it to the user in a more comprehensible format is necessary. Simulation Graphics (SimGraph) is an object-oriented data visualization software package that presents simulation data in animated graphical displays for easy interpretation. Data produced from a flight simulation is presented by SimGraph in several different formats, including: 3-Dimensional Views, Cockpit Control Views, Heads-Up Displays, Strip Charts, and Status Indicators. SimGraph can accommodate the addition of new graphical displays to allow the software to be customized to each user s particular environment. A new display can be developed and added to SimGraph without having to design a new application, allowing the graphics programmer to focus on the development of the graphical display. The SimGraph framework can be reused for a wide variety of visualization tasks. Although it was created for the flight simulation facilities at NASA Langley Research Center, SimGraph can be reconfigured to almost any data visualization environment. This paper describes the capabilities and operations of SimGraph.
NASA Technical Reports Server (NTRS)
Calaway, Michael J.; Stansbery, Eileen K.
2006-01-01
The Genesis spacecraft sampling arrays were exposed to various regimes of solar wind during flight that included: 313.01 days of high-speed wind from coronal holes, 335.19 days of low-speed inter-stream wind, 191.79 days of coronal mass ejections, and 852.83 days of bulk solar wind at Lagrange 1 orbit. Ellipsometry measurements taken at NASA s Johnson Space Center show that all nine flown array materials from the four Genesis regimes have been altered by solar wind exposure during flight. These measurements show significant changes in the optical constant for all nine ultra-pure materials that flew on Genesis when compared with their non-flight material standard. This change in the optical constant (n and k) of the material suggests that the molecular structure of the all nine ultra-pure materials have been altered by solar radiation. In addition, 50 samples of float-zone and czochralski silicon bulk array ellipsometry results were modeled with an effective medium approximation layer (EMA substrate layer) revealing a solar radiation molecular damage zone depth below the SiO2 native oxide layer ranging from 392 to 613 . This bulk solar wind radiation penetration depth is comparable to the depth of solar wind implantation depth of Mg measured by SIMS and SARISA.
An optical fiber expendable seawater temperature/depth profile sensor
NASA Astrophysics Data System (ADS)
Zhao, Qiang; Chen, Shizhe; Zhang, Keke; Yan, Xingkui; Yang, Xianglong; Bai, Xuejiao; Liu, Shixuan
2017-10-01
Marine expendable temperature/depth profiler (XBT) is a disposable measuring instrument which can obtain temperature/depth profile data quickly in large area waters and mainly used for marine surveys, scientific research, military application. The temperature measuring device is a thermistor in the conventional XBT probe (CXBT)and the depth data is only a calculated value by speed and time depth calculation formula which is not an accurate measurement result. Firstly, an optical fiber expendable temperature/depth sensor based on the FBG-LPG cascaded structure is proposed to solve the problems of the CXBT, namely the use of LPG and FBG were used to detect the water temperature and depth, respectively. Secondly, the fiber end reflective mirror is used to simplify optical cascade structure and optimize the system performance. Finally, the optical path is designed and optimized using the reflective optical fiber end mirror. The experimental results show that the sensitivity of temperature and depth sensing based on FBG-LPG cascade structure is about 0.0030C and 0.1%F.S. respectively, which can meet the requirements of the sea water temperature/depth observation. The reflectivity of reflection mirror is in the range from 48.8% to 72.5%, the resonant peak of FBG and LPG are reasonable and the whole spectrum are suitable for demodulation. Through research on the optical fiber XBT (FXBT), the direct measurement of deep-sea temperature/depth profile data can be obtained simultaneously, quickly and accurately. The FXBT is a new all-optical seawater temperature/depth sensor, which has important academic value and broad application prospect and is expected to replace the CXBT in the future.
CatSim: a new computer assisted tomography simulation environment
NASA Astrophysics Data System (ADS)
De Man, Bruno; Basu, Samit; Chandra, Naveen; Dunham, Bruce; Edic, Peter; Iatrou, Maria; McOlash, Scott; Sainath, Paavana; Shaughnessy, Charlie; Tower, Brendon; Williams, Eugene
2007-03-01
We present a new simulation environment for X-ray computed tomography, called CatSim. CatSim provides a research platform for GE researchers and collaborators to explore new reconstruction algorithms, CT architectures, and X-ray source or detector technologies. The main requirements for this simulator are accurate physics modeling, low computation times, and geometrical flexibility. CatSim allows simulating complex analytic phantoms, such as the FORBILD phantoms, including boxes, ellipsoids, elliptical cylinders, cones, and cut planes. CatSim incorporates polychromaticity, realistic quantum and electronic noise models, finite focal spot size and shape, finite detector cell size, detector cross-talk, detector lag or afterglow, bowtie filtration, finite detector efficiency, non-linear partial volume, scatter (variance-reduced Monte Carlo), and absorbed dose. We present an overview of CatSim along with a number of validation experiments.
Space Interferometry Mission: Measuring the Universe
NASA Technical Reports Server (NTRS)
Marr, James; Dallas, Saterios; Laskin, Robert; Unwin, Stephen; Yu, Jeffrey
1991-01-01
The Space Interferometry Mission (SIM) will be the NASA Origins Program's first space based long baseline interferometric observatory. SIM will use a 10 m Michelson stellar interferometer to provide 4 microarcsecond precision absolute position measurements of stars down to 20th magnitude over its 5 yr. mission lifetime. SIM will also provide technology demonstrations of synthesis imaging and interferometric nulling. This paper describes the what, why and how of the SIM mission, including an overall mission and system description, science objectives, general description of how SIM makes its measurements, description of the design concepts now under consideration, operations concept, and supporting technology program.
Huang, Jing; Xi, Jun; Huang, Zhi; Wang, Qi; Zhang, Zhen-Dong
2014-01-01
Bacteria play important roles in mineral weathering and soil formation. However, few reports of mineral weathering bacteria inhabiting subsurfaces of soil profiles have been published, raising the question of whether the subsurface weathering bacteria are fundamentally distinct from those in surface communities. To address this question, we isolated and characterized mineral weathering bacteria from two contrasting soil profiles with respect to their role in the weathering pattern evolution, their place in the community structure, and their depth-related changes in these two soil profiles. The effectiveness and pattern of bacterial mineral weathering were different in the two profiles and among the horizons within the respective profiles. The abundance of highly effective mineral weathering bacteria in the Changshu profile was significantly greater in the deepest horizon than in the upper horizons, whereas in the Yanting profile it was significantly greater in the upper horizons than in the deeper horizons. Most of the mineral weathering bacteria from the upper horizons of the Changshu profile and from the deeper horizons of the Yanting profile significantly acidified the culture media in the mineral weathering process. The proportion of siderophore-producing bacteria in the Changshu profile was similar in all horizons except in the Bg2 horizon, whereas the proportion of siderophore-producing bacteria in the Yanting profile was higher in the upper horizons than in the deeper horizons. Both profiles existed in different highly depth-specific culturable mineral weathering community structures. The depth-related changes in culturable weathering communities were primarily attributable to minor bacterial groups rather than to a change in the major population structure. PMID:24077700
Imaging Mass Spectrometry on the Nanoscale with Cluster Ion Beams
2015-01-01
Imaging with cluster secondary ion mass spectrometry (SIMS) is reaching a mature level of development. Using a variety of molecular ion projectiles to stimulate desorption, 3-dimensional imaging with the selectivity of mass spectrometry can now be achieved with submicrometer spatial resolution and <10 nm depth resolution. In this Perspective, stock is taken regarding what it will require to routinely achieve these remarkable properties. Issues include the chemical nature of the projectile, topography formation, differential erosion rates, and perhaps most importantly, ionization efficiency. Shortcomings of existing instrumentation are also noted. Speculation about how to successfully resolve these issues is a key part of the discussion. PMID:25458665
NASA Astrophysics Data System (ADS)
Milke, R.; Dohmen, R.; Wiedenbeck, M.; Wirth, R.; Abart, R.; Becker, H.-W.
2003-04-01
Grain boundary diffusion studies by the rim growth method in the system MgO(±FeO)-SiO_2 have evolved from measuring rim growth rates to the tracing of chemical components by using isotopically enriched starting materials and SIMS analyses (Milke et al. 2001). We miniaturized this setup for grain boundary diffusion experiments by using pulsed-laser deposited (PLD) thin films (Dohmen et al. 2002). The starting samples consist of polycrystalline layers of pyroxene (en90fs10) and isotopically doped (18O, 29Si) olivine (fo90fa10) with a total thickness <= 1 μm on a polished quartz surface. A first series of experiments was performed at temperatures between 1000 and 1200^oC at fO_2 of 10-10 bar. Resulting layer thickness and chemi-cal composition were measured by Rutherford Back-Scattering (RBS) and TEM using Focused Ion Beam (FIB) preparation methods. O and Si isotope profiles were measured by SIMS depth scanning. The enstatite layers thicken during the annealing experiments with well-defined interfaces by rates for Δx^2 of 700 to 50000 nm^2/h at the chosen conditions. The iso-tope profiles show that Si acts as a slow diffusing component. From the enstatite growth rates a Dgb_Aδ can be calculated, where A is the rate-determining component. This gives a Dgb_Aδ in the range of 10-26 (at 1000^oC) to 10-24 (at 1200^oC) m^3s-1, which is well in accordance with an extrapolation from the data of Fisler et al. (1997) at 1350 to 1450^oC. This indicates that over the entire interval from 1000 to 1450^oC the reaction is controlled by diffusion of the same component and more importantly that mechanisms on the nano scale are the same as on the microscopic scale. The new method has several advantages over previously used techniques. The well-defined layers on nano scale allow one to study rim growth at lower temperatures than before and avoids therefore large extrapolations to natural conditions. The very small amount of isotopically enriched material needed for one sample makes it also economically viable. The samples can be designed with variable chemical composi-tions, e.g. distinct members of the fo-fa and en-fs series. The versatility of the PLD-technique allows one to apply this method to other chemical systems as well. Ref.: Dohmen et al. (2002) Eur J Miner 14: 1155--1168; Milke et al. (2001), Contrib Miner Petrol 142: 15--26; Fisler et al. (1997) Phys Chem Minerals 24: 264--273.
Hara, Shingo; Mitsugi, Masaharu; Kanno, Takahiro; Nomachi, Akihiko; Wajima, Takehiko; Tatemoto, Yukihiro
2013-09-01
This article describes a case we experienced in which good postsurgical facial profiles were obtained for a patient with jaw deformities associated with facial asymmetry, by implementing surgical planning with SimPlant OMS. Using this method, we conducted LF1 osteotomy, intraoral vertical ramus osteotomy (IVRO), sagittal split ramus osteotomy (SSRO), mandibular constriction and mandibular border genioplasty. Not only did we obtain a class I occlusal relationship, but the complicated surgery also improved the asymmetry of the frontal view, as well as of the profile view, of the patient. The virtual operation using three-dimensional computed tomography (3D-CT) could be especially useful for the treatment of patients with jaw deformities associated with facial asymmetry.
Hara, Shingo; Mitsugi, Masaharu; Kanno, Takahiro; Nomachi, Akihiko; Wajima, Takehiko; Tatemoto, Yukihiro
2013-01-01
This article describes a case we experienced in which good postsurgical facial profiles were obtained for a patient with jaw deformities associated with facial asymmetry, by implementing surgical planning with SimPlant OMS. Using this method, we conducted LF1 osteotomy, intraoral vertical ramus osteotomy (IVRO), sagittal split ramus osteotomy (SSRO), mandibular constriction and mandibular border genioplasty. Not only did we obtain a class I occlusal relationship, but the complicated surgery also improved the asymmetry of the frontal view, as well as of the profile view, of the patient. The virtual operation using three-dimensional computed tomography (3D-CT) could be especially useful for the treatment of patients with jaw deformities associated with facial asymmetry. PMID:23907678
Fusing literature and full network data improves disease similarity computation.
Li, Ping; Nie, Yaling; Yu, Jingkai
2016-08-30
Identifying relatedness among diseases could help deepen understanding for the underlying pathogenic mechanisms of diseases, and facilitate drug repositioning projects. A number of methods for computing disease similarity had been developed; however, none of them were designed to utilize information of the entire protein interaction network, using instead only those interactions involving disease causing genes. Most of previously published methods required gene-disease association data, unfortunately, many diseases still have very few or no associated genes, which impeded broad adoption of those methods. In this study, we propose a new method (MedNetSim) for computing disease similarity by integrating medical literature and protein interaction network. MedNetSim consists of a network-based method (NetSim), which employs the entire protein interaction network, and a MEDLINE-based method (MedSim), which computes disease similarity by mining the biomedical literature. Among function-based methods, NetSim achieved the best performance. Its average AUC (area under the receiver operating characteristic curve) reached 95.2 %. MedSim, whose performance was even comparable to some function-based methods, acquired the highest average AUC in all semantic-based methods. Integration of MedSim and NetSim (MedNetSim) further improved the average AUC to 96.4 %. We further studied the effectiveness of different data sources. It was found that quality of protein interaction data was more important than its volume. On the contrary, higher volume of gene-disease association data was more beneficial, even with a lower reliability. Utilizing higher volume of disease-related gene data further improved the average AUC of MedNetSim and NetSim to 97.5 % and 96.7 %, respectively. Integrating biomedical literature and protein interaction network can be an effective way to compute disease similarity. Lacking sufficient disease-related gene data, literature-based methods such as MedSim can be a great addition to function-based algorithms. It may be beneficial to steer more resources torward studying gene-disease associations and improving the quality of protein interaction data. Disease similarities can be computed using the proposed methods at http:// www.digintelli.com:8000/ .
Phase 1 Validation Testing and Simulation for the WEC-Sim Open Source Code
NASA Astrophysics Data System (ADS)
Ruehl, K.; Michelen, C.; Gunawan, B.; Bosma, B.; Simmons, A.; Lomonaco, P.
2015-12-01
WEC-Sim is an open source code to model wave energy converters performance in operational waves, developed by Sandia and NREL and funded by the US DOE. The code is a time-domain modeling tool developed in MATLAB/SIMULINK using the multibody dynamics solver SimMechanics, and solves the WEC's governing equations of motion using the Cummins time-domain impulse response formulation in 6 degrees of freedom. The WEC-Sim code has undergone verification through code-to-code comparisons; however validation of the code has been limited to publicly available experimental data sets. While these data sets provide preliminary code validation, the experimental tests were not explicitly designed for code validation, and as a result are limited in their ability to validate the full functionality of the WEC-Sim code. Therefore, dedicated physical model tests for WEC-Sim validation have been performed. This presentation provides an overview of the WEC-Sim validation experimental wave tank tests performed at the Oregon State University's Directional Wave Basin at Hinsdale Wave Research Laboratory. Phase 1 of experimental testing was focused on device characterization and completed in Fall 2015. Phase 2 is focused on WEC performance and scheduled for Winter 2015/2016. These experimental tests were designed explicitly to validate the performance of WEC-Sim code, and its new feature additions. Upon completion, the WEC-Sim validation data set will be made publicly available to the wave energy community. For the physical model test, a controllable model of a floating wave energy converter has been designed and constructed. The instrumentation includes state-of-the-art devices to measure pressure fields, motions in 6 DOF, multi-axial load cells, torque transducers, position transducers, and encoders. The model also incorporates a fully programmable Power-Take-Off system which can be used to generate or absorb wave energy. Numerical simulations of the experiments using WEC-Sim will be presented. These simulations highlight the code features included in the latest release of WEC-Sim (v1.2), including: wave directionality, nonlinear hydrostatics and hydrodynamics, user-defined wave elevation time-series, state space radiation, and WEC-Sim compatibility with BEMIO (open source AQWA/WAMI/NEMOH coefficient parser).
Upper Ocean Profiles Measurements with ASIP
NASA Astrophysics Data System (ADS)
Ward, B.; Callaghan, A. H.; Fristedt, T.; Vialard, J.; Cuypers, Y.; Weller, R. A.; Grosch, C. E.
2009-04-01
This presentation describes results from the Air-Sea Interaction Profiler (ASIP), an autonomous profiling instrument for upper ocean measurements. The measurements from ASIP are well suited to enhancing research on air-sea interfacial and near surface processes. Autonomous profiling is accomplished with a thruster, which submerges ASIP to a programmed depth. Once this depth is reached the positively buoyant instrument will ascend to the surface acquiring data. ASIP can profile from a maximum depth of 100 m to the surface, allowing both mixed layer and near-surface measurements to be conducted. The sensor payload on ASIP include microstructure sensors (two shear probes and a thermistor); a slow response accurate thermometer; a pair of conductivity sensors; pressure for a record of depth; PAR for measurements of light absorption in the water column. Other non-environmental sensors are acceleration, rate, and heading for determination of vehicle motion. Power is provided with rechargable lithium-ion batteries, supplying 1000 Whr, allowing approximately 300 profiles. ASIP also contains an iridium/GPS system, which allows realtime reporting of its position. ASIP was deployed extensively during the Cirene Indian Ocean campaign and our results focus on the data from the temperature, salinity, light, and shear sensors.
1989-12-01
to 1983, divided by State and Province (Figure 6), show that landings in Washington (except Puget Sound ), Oregon, and California generally follow ed...sim ilar trends. Landings from Puget 1 94. ... 4-55 59-4 64, 65 69.7n . 4.75 S 79 Sound and British Columbia are lower and show less annual variation...tides that ranged from -0.60 to is given in the life history section. -0.74 m. Aerial surveys made over Puget Sound beaches using Williams’ (1979) survey
Olson, C.G.; Doolittle, J.A.
1985-01-01
Two techniques were assessed for their capabilities in reconnaissance studies of soil characteristics: depth to the water table and depth to bedrock beneath surficial deposits in mountainous terrain. Ground-penetrating radar had the best near-surface resolution in the upper 2 m of the profile and provided continuous interpretable imagery of soil profiles and bedrock surfaces. Where thick colluvium blankets side slopes, the GPR could not consistently define the bedrock interface. In areas with clayey or shaley sediments, the GPR is also more limited in defining depth and is less reliable. Seismic refraction proved useful in determining the elevation of the water table and depth to bedrock, regardless of thickness of overlying material, but could not distinguish soil-profile characteristics.-from Authors
Positional glow curve simulation for thermoluminescent detector (TLD) system design
NASA Astrophysics Data System (ADS)
Branch, C. J.; Kearfott, K. J.
1999-02-01
Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design.
Yutaka Kataoka; Makoto Kiguchi; R. Sam Williams; Philip D. Evans
2006-01-01
FT-IR microscopy was used to depth profile the photodegradation of Japanese cedar earlywood exposed to monochromatic light in the UV and visible ranges (band pass: 20nm). Parallel experiments assessed the transmission of the light through thin sections of Japanese cedar. The depth of photodegradation increased with wavelength up to and including the violet region of...
Mills, Brennen W; Carter, Owen B J; Rudd, Cobie J; Ross, Nathan P; Claxton, Louise A
2015-10-01
There is conflicting evidence surrounding the merit of clinical placements (CPs) for early-stage health-profession students. Some contend that early-stage CPs facilitate contextualization of a subsequently learned theory. Others argue that training in simulated-learning experiences (SLEs) should occur before CP to ensure that students possess at least basic competency. We sought to investigate both claims. First-year paramedicine students (n = 85) undertook 3 days of CP and SLEs as part of course requirements. Students undertook CP either before or after participation in SLEs creating 2 groups (Clin → Sim/Sim → Clin). Clinical skills acquisition was measured via direct scenario-based clinical assessments with expert observers conducted at 4 intervals during the semester. Perceptions of difficulty of CP and SLE were measured via the National Aeronautics and Space Administration Task Load Index. Students' clinical assessment scores in both groups improved significantly from beginning to end of semester (P < 0.001). However, at semester's end, clinical assessment scores for the Sim → Clin group were statistically significantly greater than those of the Clin → Sim group (P = 0.021). Both groups found SLEs more demanding than CP (P < 0.001). However, compared with the Sim → Clin group, the Clin → Sim group rated SLE as substantially more time-demanding than CP (P = 0.003). Differences in temporal demand suggest that the Clin → Sim students had fewer opportunities to practice clinical skills during CP than the Sim → Clin students due to a more limited scope of practice. The Sim → Clin students contextualized SLE within subsequent CP resulting in greater improvement in clinical competency by semester's end in comparison with the Clin → Sim students who were forced to contextualize skills retrospectively.
Zhang, Peng; Han, Fei; Li, Yunxia; Chen, Jiwu; Chen, Tianwu; Zhi, Yunlong; Jiang, Jia; Lin, Chao; Chen, Shiyi; Zhao, Peng
2016-01-01
The Ligament Advanced Reinforcement System has recently been widely used as the primary graft of choice in anterior cruciate ligament (ACL) reconstruction. But the biological graft-bone healing still remains a problem. Previous studies have shown that simvastatin (SIM) stimulates bone formation. The objective of this study was to investigate whether surface coating with collagen containing low-dose SIM microsphere could enhance the surface biocompatibility of polyethylene terephthalate (PET) artificial ligaments to accelerate graft-to-bone healing. The in vitro studies demonstrated that bone marrow stromal cells on the collagen-coated PET scaffolds (COL/PET) and simvastatin/collagen-coated PET scaffolds (SIM/COL/PET) proliferated vigorously. Compared with the PET group and the COL/PET group, SIM could induce bone marrow stromal cells' osteoblastic differentiation, high alkaline phosphatase activity, more mineralization deposition, and more expression of osteoblast-related genes, such as osteocalcin, runt-related transcription factor 2, bone morphogenetic protein-2, and vascular endothelial growth factor, in the SIM/COL/PET group. In vivo, rabbits received ACL reconstruction with different scaffolds. Histological analysis demonstrated that graft-bone healing was significantly greater with angiogenesis and osteogenesis in the SIM/COL/PET group than the other groups. In addition, biomechanical testing at the eighth week demonstrated a significant increase in the ultimate failure load and stiffness in the SIM/COL/PET group. The low dose of SIM-sustained release from SIM/COL/PET promoted the graft-bone healing via its effect on both angiogenesis and osteogenesis. This study suggested that collagen containing low-dose SIM microsphere coating on the surface of PET artificial ligaments could be potentially applied for ACL reconstruction.
A measurement system for vertical seawater profiles close to the air-sea interface
NASA Astrophysics Data System (ADS)
Sims, Richard P.; Schuster, Ute; Watson, Andrew J.; Yang, Ming Xi; Hopkins, Frances E.; Stephens, John; Bell, Thomas G.
2017-09-01
This paper describes a near-surface ocean profiler, which has been designed to precisely measure vertical gradients in the top 10 m of the ocean. Variations in the depth of seawater collection are minimized when using the profiler compared to conventional CTD/rosette deployments. The profiler consists of a remotely operated winch mounted on a tethered yet free-floating buoy, which is used to raise and lower a small frame housing sensors and inlet tubing. Seawater at the inlet depth is pumped back to the ship for analysis. The profiler can be used to make continuous vertical profiles or to target a series of discrete depths. The profiler has been successfully deployed during wind speeds up to 10 m s-1 and significant wave heights up to 2 m. We demonstrate the potential of the profiler by presenting measured vertical profiles of the trace gases carbon dioxide and dimethylsulfide. Trace gas measurements use an efficient microporous membrane equilibrator to minimize the system response time. The example profiles show vertical gradients in the upper 5 m for temperature, carbon dioxide and dimethylsulfide of 0.15 °C, 4 µatm and 0.4 nM respectively.
NASA Astrophysics Data System (ADS)
Vacik, J.; Hnatowicz, V.; Attar, F. M. D.; Mathakari, N. L.; Dahiwale, S. S.; Dhole, S. D.; Bhoraskar, V. N.
2014-10-01
Diffusion of lithium from a LiCl aqueous solution into polyether ether ketone (PEEK) and polyimide (PI) assisted by in situ irradiation with 6.5 MeV electrons was studied by the neutron depth profiling method. The number of the Li atoms was found to be roughly proportional to the diffusion time. Regardless of the diffusion time, the measured depth profiles in PEEK exhibit a nearly exponential form, indicating achievement of a steady-state phase of a diffusion-reaction process specified in the text. The form of the profiles in PI is more complex and it depends strongly on the diffusion time. For the longer diffusion time, the profile consists of near-surface bell-shaped part due to Fickian-like diffusion and deeper exponential part.
The eponymous Dr James Marion Sims MD, LLD (1813-1883).
West, M J; Irvine, L M
2015-02-01
Dr James Marion Sims was born in 1813 in Lancaster County, South Carolina. It was while pioneering numerous surgical procedures in Alabama that in 1849 he achieved the outstanding landmark in medical history of successfully, and consistently, repairing vesicovaginal fistulae. Sims soon developed a reputation as a fine surgeon, with new operations and techniques, using novel surgical instruments and his innovative approaches frequently published. Moving to New York City in 1853, he further established hospitals devoted entirely to women's health. Sims was controversial, with flamboyant descriptions of self-confident success, yet they were tempered with sober reflection of failure and loss. Today we remain with the Sims speculum and Sims position, eponymous tributes to his accomplishments as the 'Father of Gynaecology'. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Evaluation of vSim for Nursing in an Adult Health Nursing Course: A Multisite Pilot Study.
Wright, Renée R; Tinnon, Elizabeth A; Newton, Rebecca H
2018-02-01
Virtual simulation technology is the next step in using simulation as an accepted teaching-learning pedagogy in nursing. The purpose of this multisite, quasi-experimental, three-group, posttest-only design was to evaluate the effectiveness and participant satisfaction of vSim for Nursing in an Adult Health Nursing course. Although the quantitative findings (examination scores and postsimulation scores) were not statistically significant, participants overwhelmingly found vSim for Nursing to be a positive experiential learning endeavor. Ninety-one percent of the participants (n = 61) indicated that vSim for Nursing helped them understand adult health concepts and that vSim for Nursing was beneficial to learning. vSim for Nursing warrants further investigation, using other methods to measure effectiveness to ascertain whether knowledge acquisition is indeed improved as indicated by participant data in this study.
WEC-SIM Phase 1 Validation Testing -- Numerical Modeling of Experiments: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruehl, Kelley; Michelen, Carlos; Bosma, Bret
2016-08-01
The Wave Energy Converter Simulator (WEC-Sim) is an open-source code jointly developed by Sandia National Laboratories and the National Renewable Energy Laboratory. It is used to model wave energy converters subjected to operational and extreme waves. In order for the WEC-Sim code to be beneficial to the wave energy community, code verification and physical model validation is necessary. This paper describes numerical modeling of the wave tank testing for the 1:33-scale experimental testing of the floating oscillating surge wave energy converter. The comparison between WEC-Sim and the Phase 1 experimental data set serves as code validation. This paper is amore » follow-up to the WEC-Sim paper on experimental testing, and describes the WEC-Sim numerical simulations for the floating oscillating surge wave energy converter.« less
Schäfer, Martin; Le, Tung B K; Hearnshaw, Stephen J; Maxwell, Anthony; Challis, Gregory L; Wilkinson, Barrie; Buttner, Mark J
2015-06-19
Simocyclinone D8 (SD8) is a potent DNA gyrase inhibitor produced by Streptomyces antibioticus Tü6040. The simocyclinone (sim) biosynthetic gene cluster has been sequenced and a hypothetical biosynthetic pathway has been proposed. The tetraene linker in SD8 was suggested to be the product of a modular type I polyketide synthase working in trans with two monofunctional enzymes. One of these monofunctional enzymes, SimC7, was proposed to supply a dehydratase activity missing from two modules of the polyketide synthase. In this study, we report the function of SimC7. We isolated the entire ~72-kb sim cluster on a single phage artificial chromosome clone and produced simocyclinone heterologously in a Streptomyces coelicolor strain engineered for improved antibiotic production. Deletion of simC7 resulted in the production of a novel simocyclinone, 7-oxo-SD8, which unexpectedly carried a normal tetraene linker but was altered in the angucyclinone moiety. We demonstrate that SimC7 is an NAD(P)H-dependent ketoreductase that catalyzes the conversion of 7-oxo-SD8 into SD8. 7-oxo-SD8 was essentially inactive as a DNA gyrase inhibitor, and the reduction of the keto group by SimC7 was shown to be crucial for high-affinity binding to the enzyme. Thus, SimC7 is an angucyclinone ketoreductase that is essential for the biological activity of simocyclinone. Copyright © 2015. Published by Elsevier Ltd.
High-resolution depth profiling using a range-gated CMOS SPAD quanta image sensor.
Ren, Ximing; Connolly, Peter W R; Halimi, Abderrahim; Altmann, Yoann; McLaughlin, Stephen; Gyongy, Istvan; Henderson, Robert K; Buller, Gerald S
2018-03-05
A CMOS single-photon avalanche diode (SPAD) quanta image sensor is used to reconstruct depth and intensity profiles when operating in a range-gated mode used in conjunction with pulsed laser illumination. By designing the CMOS SPAD array to acquire photons within a pre-determined temporal gate, the need for timing circuitry was avoided and it was therefore possible to have an enhanced fill factor (61% in this case) and a frame rate (100,000 frames per second) that is more difficult to achieve in a SPAD array which uses time-correlated single-photon counting. When coupled with appropriate image reconstruction algorithms, millimeter resolution depth profiles were achieved by iterating through a sequence of temporal delay steps in synchronization with laser illumination pulses. For photon data with high signal-to-noise ratios, depth images with millimeter scale depth uncertainty can be estimated using a standard cross-correlation approach. To enhance the estimation of depth and intensity images in the sparse photon regime, we used a bespoke clustering-based image restoration strategy, taking into account the binomial statistics of the photon data and non-local spatial correlations within the scene. For sparse photon data with total exposure times of 75 ms or less, the bespoke algorithm can reconstruct depth images with millimeter scale depth uncertainty at a stand-off distance of approximately 2 meters. We demonstrate a new approach to single-photon depth and intensity profiling using different target scenes, taking full advantage of the high fill-factor, high frame rate and large array format of this range-gated CMOS SPAD array.
Auger analysis of a fiber/matrix interface in a ceramic matrix composite
NASA Technical Reports Server (NTRS)
Honecy, Frank S.; Pepper, Stephen V.
1988-01-01
Auger electron spectroscopy (AES) depth profiling was used to characterize the fiber/matrix interface of an SiC fiber, reaction bonded Si3N4 matrix composite. Depth profiles of the as received double coated fiber revealed concentration oscillations which disappeared after annealing the fiber in the environment used to fabricate the composite. After the composite was fractured, the Auger depth profiles showed that failure occurred in neither the Beta-SiC fiber body nor in the Si3N4 matrix but, concurrently, at the fiber coating/matrix interface and within the fiber coating itself.
Aad, G.; Abbott, B.; Abdallah, J.; ...
2014-06-01
Here, a search is presented for direct top squark pair production using events with at least two leptons including a same-flavour opposite-sign pair with invariant mass consistent with the Z boson mass, jets tagged as originating from b-quarks and missing transverse momentum. The analysis is performed with proton–proton collision data at √s = 8 TeV collected with the ATLAS detector at the LHC in 2012 corresponding to an integrated luminosity of 20.3 fb -1. No excess beyond the Standard Model expectation is observed. Interpretations of the results are provided in models based on the direct pair production of the heavier top squark state (more » $$\\sim\\atop{t}_2$$) followed by the decay to the lighter top squark state ($$\\sim\\atop{t}_1$$) via $$\\sim\\atop{t}_2$$ → Z$$\\sim\\atop{t}_1$$, and for $$\\sim\\atop{t}_1$$ pair production in natural gauge-mediated supersymmetry breaking scenarios where the neutralino ($$\\sim\\atop{χ}$$$0\\atop{1}$$) is the next-to-lightest supersymmetric particle and decays producing a Z boson and a gravitino ($$\\sim\\atop{G}$$) via the $$\\sim\\atop{χ}$$$0\\atop{1}$$ → Z G process.« less
Effects of Preoperative Simulation on Minimally Invasive Hybrid Lumbar Interbody Fusion.
Rieger, Bernhard; Jiang, Hongzhen; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Grönemeyer, Dietrich; Bosche, Bert; Schackert, Gabriele; Ruess, Daniel
2017-10-01
The main focus of this study was to evaluate how preoperative simulation affects the surgical work flow, radiation exposure, and outcome of minimally invasive hybrid lumbar interbody fusion (MIS-HLIF). A total of 132 patients who underwent single-level MIS-HLIF were enrolled in a cohort study design. Dose area product was analyzed in addition to surgical data. Once preoperative simulation was established, 66 cases (SIM cohort) were compared with 66 patients who had previously undergone MIS-HLIF without preoperative simulation (NO-SIM cohort). Dose area product was reduced considerably in the SIM cohort (320 cGy·cm 2 NO-SIM cohort: 470 cGy·cm 2 ; P < 0.01). Surgical time was shorter for the SIM cohort (155 minutes; NO-SIM cohort, 182 minutes; P < 0.05). SIM cohort had a better outcome in Numeric Rating Scale back at 6 months follow-up compared with the NO-SIM cohort (P < 0.05). Preoperative simulation reduced radiation exposure and resulted in less back pain at the 6 months follow-up time point. Preoperative simulation provided guidance in determining the correct cage height. Outcome controls enabled the surgeon to improve the procedure and the software algorithm. Copyright © 2017 Elsevier Inc. All rights reserved.
Why don't biologists use SIMS?. A critical evaluation of imaging MS
NASA Astrophysics Data System (ADS)
Heeren, R. M. A.; McDonnell, L. A.; Amstalden, E.; Luxembourg, S. L.; Altelaar, A. F. M.; Piersma, S. R.
2006-07-01
Secondary ion mass spectrometry is commonly used to study many different types of complex surfaces. Yet, compared with MALDI and ESI-MS, SIMS has not made a significant impact in biological or biomedical research. The key features of the technique, namely high spatial resolution, high detection efficiency of ions spanning a wide m/ z range, surface sensitivity and the high scan rates seem to match ideally with several questions posed at the cellular level. To this date, SIMS has had only limited success in the biological arena. Why is this and what is needed to change this? This discussion paper will critically review the advances and the usefulness of SIMS in biomedical research and compare it to other approaches that offer spatially resolved molecular information available to a researcher with a biological interest. We will demonstrate that the type of information generated by the various incarnations of SIMS is strongly dependent on sample preparation and surface condition and these phenomena are only poorly understood. Modern approaches such as the cluster gun developments, ME-SIMS, gold coating and MALDI stigmatic imaging on a SIMS instrument might change the perception of SIMS being a tool for semiconductor manufacturers and physicists, and might persuade biologists to use these innovative mass spectrometric imaging tools.
Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E
2003-01-01
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.
Combination of structured illumination and single molecule localization microscopy in one setup
NASA Astrophysics Data System (ADS)
Rossberger, Sabrina; Best, Gerrit; Baddeley, David; Heintzmann, Rainer; Birk, Udo; Dithmar, Stefan; Cremer, Christoph
2013-09-01
Understanding the positional and structural aspects of biological nanostructures simultaneously is as much a challenge as a desideratum. In recent years, highly accurate (20 nm) positional information of optically isolated targets down to the nanometer range has been obtained using single molecule localization microscopy (SMLM), while highly resolved (100 nm) spatial information has been achieved using structured illumination microscopy (SIM). In this paper, we present a high-resolution fluorescence microscope setup which combines the advantages of SMLM with SIM in order to provide high-precision localization and structural information in a single setup. Furthermore, the combination of the wide-field SIM image with the SMLM data allows us to identify artifacts produced during the visualization process of SMLM data, and potentially also during the reconstruction process of SIM images. We describe the SMLM-SIM combo and software, and apply the instrument in a first proof-of-principle to the same region of H3K293 cells to achieve SIM images with high structural resolution (in the 100 nm range) in overlay with the highly accurate position information of localized single fluorophores. Thus, with its robust control software, efficient switching between the SMLM and SIM mode, fully automated and user-friendly acquisition and evaluation software, the SMLM-SIM combo is superior over existing solutions.
Systems Engineering and Application of System Performance Modeling in SIM Lite Mission
NASA Technical Reports Server (NTRS)
Moshir, Mehrdad; Murphy, David W.; Milman, Mark H.; Meier, David L.
2010-01-01
The SIM Lite Astrometric Observatory will be the first space-based Michelson interferometer operating in the visible wavelength, with the ability to perform ultra-high precision astrometric measurements on distant celestial objects. SIM Lite data will address in a fundamental way questions such as characterization of Earth-mass planets around nearby stars. To accomplish these goals it is necessary to rely on a model-based systems engineering approach - much more so than most other space missions. This paper will describe in further detail the components of this end-to-end performance model, called "SIM-sim", and show how it has helped the systems engineering process.
Prediction and Validation of Disease Genes Using HeteSim Scores.
Zeng, Xiangxiang; Liao, Yuanlu; Liu, Yuansheng; Zou, Quan
2017-01-01
Deciphering the gene disease association is an important goal in biomedical research. In this paper, we use a novel relevance measure, called HeteSim, to prioritize candidate disease genes. Two methods based on heterogeneous networks constructed using protein-protein interaction, gene-phenotype associations, and phenotype-phenotype similarity, are presented. In HeteSim_MultiPath (HSMP), HeteSim scores of different paths are combined with a constant that dampens the contributions of longer paths. In HeteSim_SVM (HSSVM), HeteSim scores are combined with a machine learning method. The 3-fold experiments show that our non-machine learning method HSMP performs better than the existing non-machine learning methods, our machine learning method HSSVM obtains similar accuracy with the best existing machine learning method CATAPULT. From the analysis of the top 10 predicted genes for different diseases, we found that HSSVM avoid the disadvantage of the existing machine learning based methods, which always predict similar genes for different diseases. The data sets and Matlab code for the two methods are freely available for download at http://lab.malab.cn/data/HeteSim/index.jsp.
Parks, Adam C; Gfeller, Jeffrey; Emmert, Natalie; Lammert, Hannah
2017-01-01
The Structured Inventory of Malingered Symptomatology (SIMS) is a standalone symptom validity test (SVT) designed as a screening measure to detect a variety of exaggerated psychological symptoms. A number of studies have explored the accuracy of the SIMS in litigious and clinical populations, yet few have examined the validity of the SIMS in detecting feigned symptoms of postconcussional disorder (PCD) and posttraumatic stress disorder (PTSD). The present study examined the sensitivity of the SIMS in detecting undergraduate simulators (N = 78) feigning symptoms of PCD, PTSD, and the comorbid presentation of both PCD and PTSD symptomatologies. Overall, the SIMS Total score produced the highest sensitivities for the PCD symptoms and PCD+PTSD symptoms groups (.89 and .85, respectively), and to a lesser extent, the PTSD symptoms group (.69). The Affective Disorders (AF) subscale was most sensitive to the PTSD symptoms group compared to the PCD and PCD+PTSD symptoms groups. Additional sensitivity values are presented and examined at multiple scale cutoff scores. These findings support the use of the SIMS as a SVT screening measure for PCD and PTSD symptom exaggeration in neuropsychological assessment.
NASA Technical Reports Server (NTRS)
Lindensmith, Chris A.; Briggs, H. Clark; Beregovski, Yuri; Feria, V. Alfonso; Goullioud, Renaud; Gursel, Yekta; Hahn, Inseob; Kinsella, Gary; Orzewalla, Matthew; Phillips, Charles
2006-01-01
SIM Planetquest (SIM) is a large optical interferometer for making microarcsecond measurements of the positions of stars, and to detect Earth-sized planets around nearby stars. To achieve this precision, SIM requires stability of optical components to tens of picometers per hour. The combination of SIM s large size (9 meter baseline) and the high stability requirement makes it difficult and costly to measure all aspects of system performance on the ground. To reduce risks, costs and to allow for a design with fewer intermediate testing stages, the SIM project is developing an integrated thermal, mechanical and optical modeling process that will allow predictions of the system performance to be made at the required high precision. This modeling process uses commercial, off-the-shelf tools and has been validated against experimental results at the precision of the SIM performance requirements. This paper presents the description of the model development, some of the models, and their validation in the Thermo-Opto-Mechanical (TOM3) testbed which includes full scale brassboard optical components and the metrology to test them at the SIM performance requirement levels.
Sadiq Aliyu, Abubakar; Musa, Yahaya; Liman, M S; Abba, Habu T; Chaanda, Mohammed S; Ngene, Nnamani C; Garba, N N
2018-01-01
The Keffi area hosts abundant pegmatite bodies as a result of the surrounding granitic intrusions. Keffi is part of areas that are geologically classified as North Central Basement Complex. Data on the mineralogy and mineralogical zonation of the Keffi pegmatite are scanty. Hence the need to understand the geology and mineralogical zonation of Keffi pegmatites especially at different depth profiles is relevant as a study of the elemental composition of the pegmatite is essential for the estimation of its economic viability. Here, the relative standardization method of instrumental neutron activation analysis (INAA) has been used to investigate the vertical deviations of the elemental concentrations of rare earth elements (REEs) at different depth profile of Keffi pegmatite. This study adopted the following metrics in investigating the vertical variations of REEs concentrations. Namely, the total contents of rare earth elements (∑REE); ratio of light to heavy rare earth elements (LREE/HREE), which defines the enrichment or depletion of REEs; europium anomaly (Eu/Sm); La/Lu ratio relative to chondritic meteorites. The study showed no significant variations in the total content of rare elements between the vertical depth profiles (100-250m). However, higher total concentrations of REEs (~ 92.65ppm) were recorded at the upper depth of the pegmatite and the europium anomaly was consistently negative at all the depth profiles suggesting that the Keffi pegmatite is enriched with light REEs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dynamic vertical profiles of peat porewater chemistry in a northern peatland
Natalie A. Griffiths; Stephen D. Sebestyen
2016-01-01
We measured pH, cations, nutrients, and total organic carbon (TOC) over 3 years to examine weekly to monthly variability in porewater chemistry depth profiles (0â3.0 m) in an ombrotrophic bog in Minnesota, USA. We also compared temporal variation at one location to spatial variation in depth profiles at 16 locations across the bog. Most solutes exhibited large...
Modeling wildlife populations with HexSim
HexSim is a framework for constructing spatially-explicit, individual-based computer models designed for simulating terrestrial wildlife population dynamics and interactions. HexSim is useful for a broad set of modeling applications including population viability analysis for on...
Alpha particle spectroscopy using FNTD and SIM super-resolution microscopy.
Kouwenberg, J J M; Kremers, G J; Slotman, J A; Wolterbeek, H T; Houtsmuller, A B; Denkova, A G; Bos, A J J
2018-06-01
Structured illumination microscopy (SIM) for the imaging of alpha particle tracks in fluorescent nuclear track detectors (FNTD) was evaluated and compared to confocal laser scanning microscopy (CLSM). FNTDs were irradiated with an external alpha source and imaged using both methodologies. SIM imaging resulted in improved resolution, without increase in scan time. Alpha particle energy estimation based on the track length, direction and intensity produced results in good agreement with the expected alpha particle energy distribution. A pronounced difference was seen in the spatial scattering of alpha particles in the detectors, where SIM showed an almost 50% reduction compared to CLSM. The improved resolution of SIM allows for more detailed studies of the tracks induced by ionising particles. The combination of SIM and FNTDs for alpha radiation paves the way for affordable and fast alpha spectroscopy and dosimetry. © 2018 The Authors. Journal of Microscopy published by JohnWiley & Sons Ltd on behalf of Royal Microscopical Society.
Visualization of metallodrugs in single cells by secondary ion mass spectrometry imaging.
Wu, Kui; Jia, Feifei; Zheng, Wei; Luo, Qun; Zhao, Yao; Wang, Fuyi
2017-07-01
Secondary ion mass spectrometry, including nanoscale secondary ion mass spectrometry (NanoSIMS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS), has emerged as a powerful tool for biological imaging, especially for single cell imaging. SIMS imaging can provide information on subcellular distribution of endogenous and exogenous chemicals, including metallodrugs, from membrane through to cytoplasm and nucleus without labeling, and with high spatial resolution and chemical specificity. In this mini-review, we summarize recent progress in the field of SIMS imaging, particularly in the characterization of the subcellular distribution of metallodrugs. We anticipate that the SIMS imaging method will be widely applied to visualize subcellular distributions of drugs and drug candidates in single cells, exerting significant influence on early drug evaluation and metabolism in medicinal and pharmaceutical chemistry. Recent progress of SIMS applications in characterizing the subcellular distributions of metallodrugs was summarized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanzman, Edward; Dactelides, John M; Sharp, Robert
The Virtual SimCell is a method embodied in several software applications based on the Virtual Community Platform (VCP) (ANL-SF-11-049) and its Real-Time Dashboard (RTD) app. The purpose of this method is to more efficiently facilitate emergency preparedness exercises by allowing emergency preparedness exercise Simulation Cells -- SimCells -- to be established and managed through a computer network. SimCells take the place of organizations that would respond to actual emergencies, but are not participants in exercises of emergency preparedness plans. In effect, SimCells serve as actors portraying how those organizations would respond during real emergency events. The SimCell Status Board (SSB)more » is an RTD mini-app for controllers to communicate exercise events to players and each other by entering information into an integrated system of pre-defined data fields, displaying those data effectively, and preserving them for easy access during exercise evaluations.« less
NASA Technical Reports Server (NTRS)
Kaiser, Mary K. (Inventor); Adelstein, Bernard D. (Inventor); Anderson, Mark R. (Inventor); Beutter, Brent R. (Inventor); Ahumada, Albert J., Jr. (Inventor); McCann, Robert S. (Inventor)
2014-01-01
A method and apparatus for reducing the visual blur of an object being viewed by an observer experiencing vibration. In various embodiments of the present invention, the visual blur is reduced through stroboscopic image modulation (SIM). A SIM device is operated in an alternating "on/off" temporal pattern according to a SIM drive signal (SDS) derived from the vibration being experienced by the observer. A SIM device (controlled by a SIM control system) operates according to the SDS serves to reduce visual blur by "freezing" (or reducing an image's motion to a slow drift) the visual image of the viewed object. In various embodiments, the SIM device is selected from the group consisting of illuminator(s), shutter(s), display control system(s), and combinations of the foregoing (including the use of multiple illuminators, shutters, and display control systems).
Model Package Report: Hanford Soil Inventory Model SIM v.2 Build 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nichols, Will E.; Zaher, U.; Mehta, S.
The Hanford Soil Inventory Model (SIM) is a tool for the estimation of inventory of contaminants that were released to soil from liquid discharges during the U.S. Department of Energy’s Hanford Site operations. This model package report documents the construction and development of a second version of SIM (SIM-v2) to support the needs of Hanford Site Composite Analysis. The SIM-v2 is implemented using GoldSim Pro®1 software with a new model architecture that preserves the uncertainty in inventory estimates while reducing the computational burden (compared to the previous version) and allowing more traceability and transparency in calculation methodology. The calculation architecturemore » is designed in such a manner that future updates to the waste stream composition along with addition or deletion of waste sites can be performed with relative ease. In addition, the new computational platform allows for continued hardware upgrade.« less
NASA Astrophysics Data System (ADS)
Smirnov, A.; Sayer, A. M.; Holben, B. N.; Hsu, N. C.; Sakerin, S. M.; Macke, A.; Nelson, N. B.; Courcoux, Y.; Smyth, T. J.; Croot, P.; Quinn, P. K.; Sciare, J.; Gulev, S. K.; Piketh, S.; Losno, R.; Kinne, S.; Radionov, V. F.
2011-12-01
The Maritime Aerosol Network (MAN) has been collecting data over the oceans since November 2006. The MAN archive provides a valuable resource for aerosol studies in maritime environments. In the current paper we investigate correlations between ship-borne aerosol optical depth (AOD) and near-surface wind speed, either measured (onboard or from satellite) or modeled (NCEP). According to our analysis, wind speed influences columnar aerosol optical depth, although the slope of the linear regression between AOD and wind speed is not steep (∼0.004-0.005), even for strong winds over 10 m s-1. The relationships show significant scatter (correlation coefficients typically in the range 0.3-0.5); the majority of this scatter can be explained by the uncertainty on the input data. The various wind speed sources considered yield similar patterns. Results are in good agreement with the majority of previously published relationships between surface wind speed and ship-based or satellite-based AOD measurements. The basic relationships are similar for all the wind speed sources considered; however, the gradient of the relationship varies by around a factor of two depending on the wind data used.
Project Status Update and SIM Science Breadth Discussion for the Origins Subcommittee (OS)
NASA Technical Reports Server (NTRS)
Marr, James C., IV; Shao, Mike
2003-01-01
This viewgraph presentation is composed of two sections The first reviews the features and the science goals of the Space Interferometry Mission (SIM). The goals are: (1) Perform a search for other planetary systems by surveying 2000 nearby stars for astrometric signatures of planetary companion, (2) Survey a sample of 200 nearby stars for orbiting planets down to terrestrial-type masses (3) Improve best current catalog of star positions by >lOOx and extend to fainter stars to allow extension of stellar knowledge to include our entire galaxy (4) Study dynamics and evolution of stars and star clusters in our galaxy to understand how our galaxy was formed and how it will evolve. (5) Calibrate luminosities of important stars and cosmological distance indicators to improve our understanding of stellar processes and to measure precise distance in the distant universe. The presentation also reviews the accomplishments since 2002, the plans for the subsequent 6 months. The second entitled "The Breadth of SIM Science," reviews SIM science goals in a larger context. SIM will serve to complement and pave the way for the Terrestrial Planet Finder (TPF). SIM observations of the motions of stars will tell us about the distribution of all gravitating mass (light plus dark matter) in the Galaxy. SIM observations of the motions of dwarf galaxies around our own will determine the mass distribution (light plus dark matter in the Halo. SIM will greatly extend these observations to test the theories of accretion disks around super massive black holes. SIM has advantages for studying AGN and other very compact objects.
Blacklaws, Jake; Deska-Gauthier, Dylan; Jones, Christopher T; Petracca, Yanina L; Liu, Mingwei; Zhang, Han; Fawcett, James P; Glover, Joel C; Lanuza, Guillermo M; Zhang, Ying
2015-09-01
V3 spinal interneurons (INs) are a group of excitatory INs that play a crucial role in producing balanced and stable gaits in vertebrate animals. In the developing mouse spinal cord, V3 INs arise from the most ventral progenitor domain and form anatomically distinctive subpopulations in adult spinal cords. They are marked by the expression of transcription factor Sim1 postmitotically, but the function of Sim1 in V3 development remains unknown. Here, we used Sim1(Cre) ;tdTomato mice to trace the fate of V3 INs in a Sim1 mutant versus control genetic background during development. In Sim1 mutants, V3 INs are produced normally and maintain a similar position and organization as in wild types before E12.5. Further temporal analysis revealed that the V3 INs in the mutants failed to migrate properly to form V3 subgroups along the dorsoventral axis of the spinal cord. At birth, in the Sim1 mutant the number of V3 INs in the ventral subgroup was normal, but they were significantly reduced in the dorsal subgroup with a concomitant increase in the intermediate subgroup. Retrograde labeling at lumbar level revealed that loss of Sim1 led to a reduction in extension of contralateral axon projections both at E14.5 and P0 without affecting ipsilateral axon projections. These results demonstrate that Sim1 is essential for proper migration and the guidance of commissural axons of the spinal V3 INs. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Voronkov, V. V.; Falster, R.; Kim, TaeHyeong; Park, SoonSung; Torack, T.
2013-07-01
Silicon wafers, coated with a silicon nitride layer and subjected to high temperature Rapid Thermal Annealing (RTA) in Ar, show—upon a subsequent two-step precipitation anneal cycle (such as 800 °C + 1000 °C)—peculiar depth profiles of oxygen precipitate densities. Some profiles are sharply peaked near the wafer surface, sometimes with a zero bulk density. Other profiles are uniform in depth. The maximum density is always the same. These profiles are well reproduced by simulations assuming that precipitation starts from a uniformly distributed small oxide plates originated from RTA step and composed of oxygen atoms and vacancies ("VO2 plates"). During the first step of the precipitation anneal, an oxide layer propagates around this core plate by a process of oxygen attachment, meaning that an oxygen-only ring-shaped plate emerges around the original plate. These rings, depending on their size, then either dissolve or grow during the second part of the anneal leading to a rich variety of density profiles.
High-sensitivity aeromagnetic survey of the US Atlantic continental margin.
Behrendt, John C.; Klitgord, Kim D.
1980-01-01
The US Geological Survey contracted a high-sensitivity, digital aeromagnetic survey that was flown over the US Atlantic continental margin over a period of 15 months between 1974 and 1976. The 185 000 km of profile data have a relative accuracy approaching a few tenths of a nanotesla, which allowed compilation into maps at a scale of 1:250 000, with a contour interval of 2 nT. Automatic data processing using the Werner method allowed calculations of apparent depth to sources of the magnetic anomalies on all of the profiles, assuming a dike or interface as a source. Comparison of the computed depths to magnetic basement with multichannel seismic profiles across the survey area helped to reduce ambiguities in magnetic depth estimates and enabled interpolation of basement structures between seismic profiles. The resulting map showing depth to basement of the Atlantic continental margin is compatible with available multichannel seismic data, and we consider it a reasonable representation of the base of the sedimentary column. -Authors
Perfect Composition Depth Profiling of Ionic Liquid Surfaces Using High-resolution RBS/ERDA.
Nakajima, Kaoru; Zolboo, Enkhbayar; Ohashi, Tomohiro; Lísal, Martin; Kimura, Kenji
2016-01-01
In order to reveal the surface structures of large molecular ionic liquids (ILs), the near-surface elemental depth distributions of 1-alkyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C n C 1 Im][Tf 2 N], n = 2, 6, 10) were studied using high-resolution Rutherford backscattering spectroscopy (HRBS) in combination with high-resolution elastic recoil detection analysis (HR-ERDA). The elemental depth profiles of all constituent elements, including hydrogen, were derived from HR-ERDA/HRBS measurements, so that the profiles would reproduce both HR-ERDA and HRBS spectra simultaneously. The derived elemental depth profiles agree with state-of-the-art molecular dynamics simulations, indicating the feasibility of this method. A controversy concerning the preferential orientation of [C 2 C 1 Im] at the surface has been resolved by this new combination analysis; namely, the [C 2 C 1 Im] cation has a preferential orientation with the ethyl chain pointing towards the vacuum in the topmost molecular layer.
Objective fitting of hemoglobin dynamics in traumatic bruises based on temperature depth profiling
NASA Astrophysics Data System (ADS)
Vidovič, Luka; Milanič, Matija; Majaron, Boris
2014-02-01
Pulsed photothermal radiometry (PPTR) allows noninvasive measurement of laser-induced temperature depth profiles. The obtained profiles provide information on depth distribution of absorbing chromophores, such as melanin and hemoglobin. We apply this technique to objectively characterize mass diffusion and decomposition rate of extravasated hemoglobin during the bruise healing process. In present study, we introduce objective fitting of PPTR data obtained over the course of the bruise healing process. By applying Monte Carlo simulation of laser energy deposition and simulation of the corresponding PPTR signal, quantitative analysis of underlying bruise healing processes is possible. Introduction of objective fitting enables an objective comparison between the simulated and experimental PPTR signals. In this manner, we avoid reconstruction of laser-induced depth profiles and thus inherent loss of information in the process. This approach enables us to determine the value of hemoglobin mass diffusivity, which is controversial in existing literature. Such information will be a valuable addition to existing bruise age determination techniques.
NASA Astrophysics Data System (ADS)
Erić, M.; Petrović, S.; Kokkoris, M.; Lagoyannis, A.; Paneta, V.; Harissopulos, S.; Telečki, I.
2012-03-01
This work reports on the experimentally obtained depth profiles of 4 MeV 14N2+ ions implanted in the <1 0 0>, <1 1 0> and randomly oriented silicon crystals. The ion fluence was 1017 particles/cm2. The nitrogen depth profiling has been performed using the Nuclear Reaction Analysis (NRA) method, via the study of 14N(d,α0)12C and 14N(d,α1)12C nuclear reactions, and with the implementation of SRIM 2010 and SIMNRA computer simulation codes. For the randomly oriented silicon crystal, change of the density of silicon matrix and the nitrogen "bubble" formation have been proposed as the explanation for the difference between the experimental and simulated nitrogen depth profiles. During the implantation, the RBS/C spectra were measured on the nitrogen implanted and on the virgin crystal spots. These spectra provide information on the amorphization of the silicon crystals induced by the ion implantation.
LINKING Lyα AND LOW-IONIZATION TRANSITIONS AT LOW OPTICAL DEPTH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaskot, A. E.; Oey, M. S.
2014-08-20
We suggest that low optical depth in the Lyman continuum (LyC) may relate the Lyα emission, C II and Si II absorption, and C II* and Si II* emission seen in high-redshift galaxies. We base this analysis on Hubble Space Telescope Cosmic Origins Spectrograph spectra of four Green Pea (GP) galaxies, which may be analogs of z > 2 Lyα emitters (LAEs). In the two GPs with the strongest Lyα emission, the Lyα line profiles show reduced signs of resonant scattering. Instead, the Lyα profiles resemble the Hα line profiles of evolved star ejecta, suggesting that the Lyα emission originatesmore » from a low column density and similar outflow geometry. The weak C II absorption and presence of non-resonant C II* emission in these GPs support this interpretation and imply a low LyC optical depth along the line of sight. In two additional GPs, weak Lyα emission and strong C II absorption suggest a higher optical depth. These two GPs differ in their Lyα profile shapes and C II* emission strengths, however, indicating different inclinations of the outflows to our line of sight. With these four GPs as examples, we explain the observed trends linking Lyα, C II, and C II* in stacked LAE spectra, in the context of optical depth and geometric effects. Specifically, in some galaxies with strong Lyα emission, a low LyC optical depth may allow Lyα to escape with reduced scattering. Furthermore, C II absorption, C II* emission, and Lyα profile shape can reveal the optical depth, constrain the orientation of neutral outflows in LAEs, and identify candidate LyC emitters.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, Sylvia -Monique; Wilson, Kathryn; Koch-Muller, Monika
Majoritic garnet, characterized by an excess of silicon (>3 Si per formula unit), is considered one of the major phases of the Earth’s transition zone from 410-660 km depth. Quantifying the H 2O content of nominally anhydrous mantle minerals is necessary to evaluate their water storage capacity from experiments and modeling the Earth’s deep water cycle. We present mineral-specific infrared absorption coefficients for the purpose of quantifying the amount of water incorporated into majorite as hydroxyl point defects. A suite of majoritic garnet samples with varying proportions of Si, Fe, Al, Cr and H 2O was synthesized at conditions ofmore » 18-19 GPa and 1500-1800°C. Single-crystals were characterized using X-ray diffraction, electron microprobe analysis, secondary Ion Mass spectrometry (SIMS), IR, Raman and Mössbauer spectroscopy. We utilize SIMS and Raman spectroscopy in combination with IR spectroscopy to provide IR absorption coefficients for water in majoritic garnets with the general mineral formula (Mg,Fe) 3(Si,Mg,Fe,Al,Cr) 2[SiO4] 3. Furthermore, the IR absorption coefficient for majoritic garnet in the OH stretching region is frequency-dependent and ranges from 10 470 ± 3100 Lmol-1cm-2 to 23 400 ± 2300 Lmol -1cm -2.« less
Influence of Ta doping in resistive switching behavior of TiO2
NASA Astrophysics Data System (ADS)
Barman, Arabinda; Saini, Chetan P.; Deshmukh, Sujit; Dhar, Sankar; Kanjilal, Aloke
An approach has been made to understand the resistive switching behavior in Ta-doped TiO2 films on Pt substrates. Prior to thin film deposition, Ta-doped TiO2 powder has been synthesized chemically using Ta and Ti precursor solutions. However, the Ta doping has seriously been affected by increasing Ta concentration above 1 at% due to the segregation of Ta2O5 phase. The Ta-doped TiO2 targets have been prepared for pulsed laser deposition of the films on Pt substrates using an excitation wavelength of 248 nm. The structural and chemical properties of the Ta-doped TiO2 films have been investigated in details with the help of XRD, SIMS, XAS and XPS. The stoichiometry of the Ta-doped TiO2 films with increasing depth has been verified initially by SIMS. The electrical study of the corresponding device structures further suggests that the optimized resistive switching effect can be accomplished up to a threshold Ta-doping of 1 at%. Nevertheless, a highly conducting behavior has been shown when the TiO2 films are doped with 2 at% Ta. These results will be discussed in details in the light of defect induced resistive switching phenomenon.
Quantification of water in majoritic garnet
Thomas, Sylvia -Monique; Wilson, Kathryn; Koch-Muller, Monika; ...
2015-05-01
Majoritic garnet, characterized by an excess of silicon (>3 Si per formula unit), is considered one of the major phases of the Earth’s transition zone from 410-660 km depth. Quantifying the H 2O content of nominally anhydrous mantle minerals is necessary to evaluate their water storage capacity from experiments and modeling the Earth’s deep water cycle. We present mineral-specific infrared absorption coefficients for the purpose of quantifying the amount of water incorporated into majorite as hydroxyl point defects. A suite of majoritic garnet samples with varying proportions of Si, Fe, Al, Cr and H 2O was synthesized at conditions ofmore » 18-19 GPa and 1500-1800°C. Single-crystals were characterized using X-ray diffraction, electron microprobe analysis, secondary Ion Mass spectrometry (SIMS), IR, Raman and Mössbauer spectroscopy. We utilize SIMS and Raman spectroscopy in combination with IR spectroscopy to provide IR absorption coefficients for water in majoritic garnets with the general mineral formula (Mg,Fe) 3(Si,Mg,Fe,Al,Cr) 2[SiO4] 3. Furthermore, the IR absorption coefficient for majoritic garnet in the OH stretching region is frequency-dependent and ranges from 10 470 ± 3100 Lmol-1cm-2 to 23 400 ± 2300 Lmol -1cm -2.« less
Sixty GHz IMPATT diode development
NASA Technical Reports Server (NTRS)
Ma, Y. E.; Chen, J.; Benko, E.; Barger, M. J.; Nghiem, H.; Trinh, T. Q.; Kung, J.
1985-01-01
The objective of this program is to develop 60 GHz GaAs IMPATT Diodes suitable for communications applications. The performance goal of the 60 GHz IMPATT is 1W CW output power with a conversion efficiency of 15 percent and 10 year life time. During the course of the program, double drift (DD) GaAs IMPATT Diodes have been developed resulting in the state of the art performance at V band frequencies. A CW output power of 1.12 W was demonstrated at 51.9 GHz with 9.7 percent efficiency. The best conversion efficiency achieved was 15.3 percent. V band DD GaAs IMPATTs were developed using both small signal and large signal analyses. GaAs wafers of DD flat, DD hybrid, and DD Read profiles using molecular beam epitaxy (MBE) were developed with excellent doping profile control. Wafer evaluation was routinely made by the capacitance versus voltage (C-V) measurement. Ion mass spectrometry (SIMS) analysis was also used for more detailed profile evaluation.
Artist concept of SIM PlanetQuest Artist Concept
2002-12-21
Artist's concept of the current mission configuration. SIM PlanetQuest (formerly called Space Interferometry Mission), currently under development, will determine the positions and distances of stars several hundred times more accurately than any previous program. This accuracy will allow SIM to determine the distances to stars throughout the galaxy and to probe nearby stars for Earth-sized planets. SIM will open a window to a new world of discoveries. http://photojournal.jpl.nasa.gov/catalog/PIA04248
Alwaal, Amjad; Al-Qaoud, Talal M; Haddad, Richard L; Alzahrani, Tarek M; Delisle, Josee; Anidjar, Maurice
2015-01-01
Assessing the predictive validity of the LapSim simulator within a urology residency program. Twelve urology residents at McGill University were enrolled in the study between June 2008 and December 2011. The residents had weekly training on the LapSim that consisted of 3 tasks (cutting, clip-applying, and lifting and grasping). They underwent monthly assessment of their LapSim performance using total time, tissue damage and path length among other parameters as surrogates for their economy of movement and respect for tissue. The last residents' LapSim performance was compared with their first performance of radical nephrectomy on anesthetized porcine models in their 4(th) year of training. Two independent urologic surgeons rated the resident performance on the porcine models, and kappa test with standardized weight function was used to assess for inter-observer bias. Nonparametric spearman correlation test was used to compare each rater's cumulative score with the cumulative score obtained on the porcine models in order to test the predictive validity of the LapSim simulator. The kappa results demonstrated acceptable agreement between the two observers among all domains of the rating scale of performance except for confidence of movement and efficiency. In addition, poor predictive validity of the LapSim simulator was demonstrated. Predictive validity was not demonstrated for the LapSim simulator in the context of a urology residency training program.
Strontium Incorporation Into Calcite Generated by Bacterial Ureolysis
NASA Astrophysics Data System (ADS)
Fujita, Y.; Ingram, J. A.; Cortez, M. M.; Redden, G. D.; Smith, R. W.
2002-12-01
Strontium incorporation into calcite generated by bacterial ureolytic activity was investigated as part of a larger effort to evaluate the use of in situ urea hydrolysis for accelerating co-precipitation of trace metals and radionuclides in contaminated aquifers. 90Sr, a uranium fission product with a half-life of 29 years, is a significant subsurface contaminant at several Department of Energy facilities and could be immobilized using this remediation strategy. Experiments were conducted in a medium designed to simulate the groundwater of the Snake River Plain Aquifer in eastern Idaho, amended with strontium. Initially the solution was undersaturated with respect to calcite. As a model ureolytic organism, we used Bacillus pasteurii, a well-characterized bacterium known for high urease activity and previously shown to induce calcite precipitation in urea-amended medium. To gain information on the effect of the bacterial surfaces, we also looked at precipitation in the presence of a bacterial species that did not hydrolyze urea, as well as in the absence of bacteria. In the absence of bacterial ureolysis, carbonate precipitation was induced by addition of ammonium carbonate. All products were identified as calcite by X-ray diffraction. Strontium uptake was observed in all cases, but was greatest in the system including bacterial ureolysis. Sputter depth element profiling by time-of-flight secondary ion mass spectrometry (TOF-SIMS) confirmed this finding, showing highest Sr:Ca ratios in the bacterially generated calcite throughout the depth (~350 nm) investigated. Environmental Scanning Electron Microscopy (ESEM) of the solids revealed regular crystals containing the outlines of embedded or entombed bacterial cells, suggesting that calcite precipitated directly on the cell surfaces when present. Analysis by X-ray Absorption Near Edge Spectroscopy (XANES) indicated that in both the biotically and abiotically generated calcites the Sr was incorporated into the calcite lattice structure, rather than forming strontium carbonate. These findings are encouraging with respect to long term containment and stabilization of strontium by the proposed remediation strategy.
Multiple ion beam irradiation for the study of radiation damage in materials
NASA Astrophysics Data System (ADS)
Taller, Stephen; Woodley, David; Getto, Elizabeth; Monterrosa, Anthony M.; Jiao, Zhijie; Toader, Ovidiu; Naab, Fabian; Kubley, Thomas; Dwaraknath, Shyam; Was, Gary S.
2017-12-01
The effects of transmutation produced helium and hydrogen must be included in ion irradiation experiments to emulate the microstructure of reactor irradiated materials. Descriptions of the criteria and systems necessary for multiple ion beam irradiation are presented and validated experimentally. A calculation methodology was developed to quantify the spatial distribution, implantation depth and amount of energy-degraded and implanted light ions when using a thin foil rotating energy degrader during multi-ion beam irradiation. A dual ion implantation using 1.34 MeV Fe+ ions and energy-degraded D+ ions was conducted on single crystal silicon to benchmark the dosimetry used for multi-ion beam irradiations. Secondary Ion Mass Spectroscopy (SIMS) analysis showed good agreement with calculations of the peak implantation depth and the total amount of iron and deuterium implanted. The results establish the capability to quantify the ion fluence from both heavy ion beams and energy-degraded light ion beams for the purpose of using multi-ion beam irradiations to emulate reactor irradiated microstructures.
A Virtual Research Environment for a Secondary Ion Mass Spectrometer (SIMS)
NASA Astrophysics Data System (ADS)
Wiedenbeck, M.; Schäfer, L.; Klump, J.; Galkin, A.
2013-12-01
Overview: This poster describes the development of a Virtual Research Environment for the Secondary Ion Mass Spectrometer (SIMS) at GFZ Potsdam. Background: Secondary Ion Mass Spectrometers (SIMS) are extremely sensitive instruments for analyzing the surfaces of solid and thin film samples. These instruments are rare, expensive and experienced operators are very highly sought after. As such, measurement time is a precious commodity, until now only accessible to small numbers of researchers. The challenge: The Virtual SIMS Project aims to set up a Virtual Research Environment for the operation of the CAMECA IMS 1280-HR instrument at the GFZ Potsdam. The objective of the VRE is to provide SIMS access not only to researchers locally present in Potsdam but also to scientists working with SIMS cooperation partners in e.g., South Africa, Brazil or India. The requirements: The system should address the complete spectrum of laboratory procedures - from online application for measurement time, to remote access for data acquisition to data archiving for the subsequent publication and for future reuse. The approach: The targeted Virtual SIMS Environment will consist of a: 1. Web Server running the Virtual SIMS website providing general information about the project, lab access proposal forms and calendar for the timing of project related tasks. 2. LIMS Server, responsible for scheduling procedures, data management and, if applicable, accounting and billing. 3. Remote SIMS Tool, devoted to the operation of the experiment within a remote control environment. 4. Publishing System, which supports the publication of results in cooperation with the GFZ Library services. 5. Training Simulator, which offers the opportunity to rehearse experiments and to prepare for possible events such as a power outages or interruptions to broadband services. First results: The SIMS Virtual Research Environment will be mainly based on open source software, the only exception being the CAMECA IMS 1280-HR SIMS operating under LabView. The Publishing System will be based on eSciDoc, which is already successfully used by the GFZ scientific library. For the LIMS Server we are currently testing various options. The challenge, however, is the successful integration of all the various components and, where necessary, the definition of useful interfaces between the modules.
Role of ghrelin in small intestinal motility following pediatric intracerebral hemorrhage in mice.
Zan, Jieyu; Song, Lei; Wang, Jiejie; Zou, Rong; Hong, Fei; Zhao, Jinhua; Cheng, Yijun; Xu, Ming
2017-11-01
Small intestinal motility (SIM) disorder is a common complication following pediatric intracerebral hemorrhage (ICH), leading to a poor prognosis in patients. Previous studies have shown that ghrelin is involved in SIM in various diseases; however, the role of ghrelin in pediatric ICH‑induced SIM disorder remains to be elucidated. The present study was designed to investigate the association between ghrelin and SIM post‑ICH, and to examine the effect of exogenous ghrelin administration on SIM in vivo. An ICH model was induced in mice by autologous blood infusion. Neurobehavioral deficits were evaluated using a Rotarod test, forelimb placing test, and corner turn test. Intestinal mucosal damage was examined using hematoxylin and eosin staining. SIM was measured using charcoal meal staining. An enzyme‑linked immunosorbent assay was used to evaluate serum levels of ghrelin and nitric oxide (NO). Reverse transcription‑quantitative polymerase chain reaction and western blot analyses were performed to determine the levels of inducible nitric oxide synthase (iNOS), neuronal nitric oxide synthase (nNOS) and endothelial nitric oxide synthase (eNOS) at the mRNA and protein levels. Nω‑nitro‑L‑arginine methyl ester hydrochloride (L‑NAME), L‑arginine, atropine, phentolamine and propranolol were used to manipulate the putative pathways induced by ghrelin. Neurological dysfunction was observed post‑ICH. ICH caused damage to the intestinal mucosa and delayed SIM. Serum levels of ghrelin increased between 3 h and 3 days, peaking at 12 h, and showed a significant negative correlation with SIM post‑ICH. Ghrelin administration dose‑dependently attenua-ted ICH‑induced SIM disorder. Ghrelin also decreased NO levels by downregulating the mRNA and protein expression levels of iNOS, but not those of nNOS or eNOS, post‑ICH. Consistently, the effect was enhanced by L‑NAME and weakened by L‑arginine, respectively. The protective effect of ghrelin was eradicated by atropine, but not phentolamine or propranolol. These findings suggested that ghrelin ameliorated SIM disorder by downregulating iNOS/NO via the cholinergic pathway. Therefore, ghrelin may serve as a potential biomarker and useful target in ICH‑induced SIM disorder.
Bengtsson, Linus; Lu, Xin; Thorson, Anna; Garfield, Richard; von Schreeb, Johan
2011-01-01
Background Population movements following disasters can cause important increases in morbidity and mortality. Without knowledge of the locations of affected people, relief assistance is compromised. No rapid and accurate method exists to track population movements after disasters. We used position data of subscriber identity module (SIM) cards from the largest mobile phone company in Haiti (Digicel) to estimate the magnitude and trends of population movements following the Haiti 2010 earthquake and cholera outbreak. Methods and Findings Geographic positions of SIM cards were determined by the location of the mobile phone tower through which each SIM card connects when calling. We followed daily positions of SIM cards 42 days before the earthquake and 158 days after. To exclude inactivated SIM cards, we included only the 1.9 million SIM cards that made at least one call both pre-earthquake and during the last month of study. In Port-au-Prince there were 3.2 persons per included SIM card. We used this ratio to extrapolate from the number of moving SIM cards to the number of moving persons. Cholera outbreak analyses covered 8 days and tracked 138,560 SIM cards. An estimated 630,000 persons (197,484 Digicel SIM cards), present in Port-au-Prince on the day of the earthquake, had left 19 days post-earthquake. Estimated net outflow of people (outflow minus inflow) corresponded to 20% of the Port-au-Prince pre-earthquake population. Geographic distribution of population movements from Port-au-Prince corresponded well with results from a large retrospective, population-based UN survey. To demonstrate feasibility of rapid estimates and to identify areas at potentially increased risk of outbreaks, we produced reports on SIM card movements from a cholera outbreak area at its immediate onset and within 12 hours of receiving data. Conclusions Results suggest that estimates of population movements during disasters and outbreaks can be delivered rapidly and with potentially high validity in areas with high mobile phone use. Please see later in the article for the Editors' Summary PMID:21918643
Wear-Induced Changes in FSW Tool Pin Profile: Effect of Process Parameters
NASA Astrophysics Data System (ADS)
Sahlot, Pankaj; Jha, Kaushal; Dey, G. K.; Arora, Amit
2018-06-01
Friction stir welding (FSW) of high melting point metallic (HMPM) materials has limited application due to tool wear and relatively short tool life. Tool wear changes the profile of the tool pin and adversely affects weld properties. A quantitative understanding of tool wear and tool pin profile is crucial to develop the process for joining of HMPM materials. Here we present a quantitative wear study of H13 steel tool pin profile for FSW of CuCrZr alloy. The tool pin profile is analyzed at multiple traverse distances for welding with various tool rotational and traverse speeds. The results indicate that measured wear depth is small near the pin root and significantly increases towards the tip. Near the pin tip, wear depth increases with increase in tool rotational speed. However, change in wear depth near the pin root is minimal. Wear depth also increases with decrease in tool traverse speeds. Tool pin wear from the bottom results in pin length reduction, which is greater for higher tool rotational speeds, and longer traverse distances. The pin profile changes due to wear and result in root defect for long traverse distance. This quantitative understanding of tool wear would be helpful to estimate tool wear, optimize process parameters, and tool pin shape during FSW of HMPM materials.
HexSim: a modeling environment for ecology and conservation.
HexSim is a powerful and flexible new spatially-explicit, individual based modeling environment intended for use in ecology, conservation, genetics, epidemiology, toxicology, and other disciplines. We describe HexSim, illustrate past applications that contributed to our >10 year ...
GIS Well Temperature Data from the Roosevelt Hot Springs, Utah FORGE Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gwynn, Mark; Hill, Jay; Allis, Rick
This is a GIS point feature shapefile representing wells, and their temperatures, that are located in the general Utah FORGE area near Milford, Utah. There are also fields that represent interpolated temperature values at depths of 200 m, 1000 m, 2000 m, 3000 m, and 4000 m. in degrees Fahrenheit. The temperature values at specific depths as mentioned above were derived as follows. In cases where the well reached a given depth (200 m and 1, 2, 3, or 4 km), the temperature is the measured temperature. For the shallower wells (and at deeper depths in the wells reaching onemore » or more of the target depths), temperatures were extrapolated from the temperature-depth profiles that appeared to have stable (re-equilibrated after drilling) and linear profiles within the conductive regime (i.e. below the water table or other convective influences such as shallow hydrothermal outflow from the Roosevelt Hydrothermal System). Measured temperatures/gradients from deeper wells (when available and reasonably close to a given well) were used to help constrain the extrapolation to greater depths. Most of the field names in the attribute table are intuitive, however HF = heat flow, intercept = the temperature at the surface (x-axis of the temperature-depth plots) based on the linear segment of the plot that was used to extrapolate the temperature profiles to greater depths, and depth_m is the total well depth. This information is also present in the shapefile metadata.« less
Waninger, Kevin N; Goodbred, Andrew; Vanic, Keith; Hauth, John; Onia, Joshua; Stoltzfus, Jill; Melanson, Scott
2014-07-01
To investigate (1) cardiopulmonary resuscitation (CPR) adequacy during simulated cardiac arrest of equipped football players and (2) whether protective football equipment impedes CPR performance measures. Exploratory crossover study performed on Laerdal SimMan 3 G interactive manikin simulator. Temple University/St Luke's University Health Network Regional Medical School Simulation Laboratory. Thirty BCLS-certified ATCs and 6 ACLS-certified emergency department technicians. Subjects were given standardized rescuer scenarios to perform three 2-minute sequences of compression-only CPR. Baseline CPR sequences were captured on each subject. Experimental conditions included 2-minute sequences of CPR either over protective football shoulder pads or under unlaced pads. Subjects were instructed to adhere to 2010 American Heart Association guidelines (initiation of compressions alone at 100/min to 51 mm). Dependent variables included average compression depth, average compression rate, percentage of time chest wall recoiled, and percentage of hands-on contact during compressions. Differences between subject groups were not found to be statistically significant, so groups were combined (n = 36) for analysis of CPR compression adequacy. Compression depth was deeper under shoulder pads than over (P = 0.02), with mean depths of 36.50 and 31.50 mm, respectively. No significant difference was found with compression rate or chest wall recoil. Chest compression depth is significantly decreased when performed over shoulder pads, while there is no apparent effect on rate or chest wall recoil. Although the clinical outcomes from our observed 15% difference in compression depth are uncertain, chest compression under the pads significantly increases the depth of compressions and more closely approaches American Heart Association guidelines for chest compression depth in cardiac arrest.
SIM PlanetQuest: Science with the Space Interferometry Mission
NASA Technical Reports Server (NTRS)
Unwin, Stephen (Editor); Turyshev, Slava (Editor)
2004-01-01
SIM - the Space Interferometry Mission - will perform precision optical astrometry on objects as faint as R magnitude 20. It will be the first space-based astrometric interferometer, operating in the optical band with a 10-m baseline. The Project is managed by the Jet Propulsion Laboratory, California Institute of Technology, in close collaboration with two industry partners, Lockheed Martin Missiles and Space, and TRW Inc., Space and Electronics Group. Launch of SIM is currently planned for 2009. In its wide-angle astrometric mode, SIM will yield 4 microarcsecond absolute position and parallax measurements. Astrometric planet searches will be done in a narrow-angle mode, with an accuracy of 4 microarcseconds or better in a single measurement. As a pointed rather than a survey instrument, SIM will maintain.its astrometric accuracy down to the faintest, magnitudes, opening up the opportunity for astrometry of active galactic nuclei to better than 10 pas. SIM will define a new astrometric reference frame, using a grid of approximately 1500 stars with positions accurate to 4 microarcseconds. The SIM Science Team comprises the Principal Investigators of ten Key Projects, and five Mission Scientists contributing their expertise to specific areas of the mission. Their science programs cover a wide range of topics in Galactic and extragalactic astronomy. They include: searches for low-mass planets - including analogs to our own solar system - tlie formation and dynamics of our Galaxy, calibration of the cosmic distance scale, and fundamental stellar astrophysics. All of the science observing on SIM is competitively awarded; the Science Team programs total about 40% of the total available, and the remainder will be assigned via future NASA competitions. This report is a compilation of science summaries by members of the Science Team, and it illustrates the wealth of scientific problems that microarcsecond-precision astrometry can contribute to. More information on SIM, including copies of this report, may be obtained from the project web site, at http://sim. jpl.nasa.gov.
Bio-SimVerb and Bio-SimLex: wide-coverage evaluation sets of word similarity in biomedicine.
Chiu, Billy; Pyysalo, Sampo; Vulić, Ivan; Korhonen, Anna
2018-02-05
Word representations support a variety of Natural Language Processing (NLP) tasks. The quality of these representations is typically assessed by comparing the distances in the induced vector spaces against human similarity judgements. Whereas comprehensive evaluation resources have recently been developed for the general domain, similar resources for biomedicine currently suffer from the lack of coverage, both in terms of word types included and with respect to the semantic distinctions. Notably, verbs have been excluded, although they are essential for the interpretation of biomedical language. Further, current resources do not discern between semantic similarity and semantic relatedness, although this has been proven as an important predictor of the usefulness of word representations and their performance in downstream applications. We present two novel comprehensive resources targeting the evaluation of word representations in biomedicine. These resources, Bio-SimVerb and Bio-SimLex, address the previously mentioned problems, and can be used for evaluations of verb and noun representations respectively. In our experiments, we have computed the Pearson's correlation between performances on intrinsic and extrinsic tasks using twelve popular state-of-the-art representation models (e.g. word2vec models). The intrinsic-extrinsic correlations using our datasets are notably higher than with previous intrinsic evaluation benchmarks such as UMNSRS and MayoSRS. In addition, when evaluating representation models for their abilities to capture verb and noun semantics individually, we show a considerable variation between performances across all models. Bio-SimVerb and Bio-SimLex enable intrinsic evaluation of word representations. This evaluation can serve as a predictor of performance on various downstream tasks in the biomedical domain. The results on Bio-SimVerb and Bio-SimLex using standard word representation models highlight the importance of developing dedicated evaluation resources for NLP in biomedicine for particular word classes (e.g. verbs). These are needed to identify the most accurate methods for learning class-specific representations. Bio-SimVerb and Bio-SimLex are publicly available.
NASA Astrophysics Data System (ADS)
Schulze, D. J.; Page, Z.; Harte, B.; Valley, J.; Channer, D.; Jaques, L.
2006-12-01
Using ion microprobes and secondary-ion mass spectrometry we have analyzed the carbon and oxygen isotopic composition of eclogite-suite diamonds and their coesite inclusions, respectively, from three suites of diamonds of Proterozoic age. Extremely high (for the mantle) oxygen isotope values (delta 18O of +10.2 to +16.9 per mil VSMOW) are preserved in coesites included in eclogitic diamonds from Guaniamo, Venezuela (Schulze et al., Nature, 2003), providing compelling evidence for an origin of their eclogite hosts by subduction of sea water altered ocean floor basalts. In situ SIMS analyses of their host diamonds yield carbon isotope values (delta 13C) of -12 to -18 per mil PDB. SIMS analyses of coesite inclusions from Argyle, Australia diamonds previously analyzed by combustion methods for d13C composition (Jaques et al., Proc. 4th Kimb. Conf, 1989), also yield anomalously high d18O values (+6.8 to +16.0 per mil VSMOW), that correlate with the anomalously low carbon isotope values (-10.3 to -14.1 per mil PDB). One coesite-bearing diamond from Orapa, Botswana analyzed in situ by SIMS has a d18O value of the coesite of +8.5 per mil VSMOW and a d13C value of the adjacent diamond host of -9.0 per mil PDB. A second Orapa stone has a SIMS carbon isotope compositional range of d13C = -14 to -16 per mil PDB, but the coesite is too small for ion probe analysis. At each of these localities, carbon isotope values of coesite-bearing diamonds that are lower than typical of mantle carbon are correlated with oxygen isotope compositions of included coesites that are substantially above the common mantle oxygen isotope range. Such results are not in accord with diamond genesis models involving formation of eclogitic diamonds from igneous melts undergoing fractionation in the mantle or by crystallization from primordial inhomogeneities in Earth's mantle. By analogy with the oxygen isotope compositions of altered ocean floor basalts and Alpine (subduction zone) eclogites they are, however, consistent with a subduction origin for these eclogite assemblages from altered ocean floor basaltic protoliths, and thus the simplest explanation for the source of the low carbon isotope values of these diamonds is formation from biogenic carbon accumulated on or near the ocean floor and subducted to the depths of eclogite and diamond stability with the altered basalts. Significantly these results, which were not predicted from studies of diamond-bearing eclogites, apply to the mantle beneath three different continental crustal blocks of both Proterozoic (Guaniamo and Argyle) and Archean/Proterozoic (Orapa) age.
TOF-SIMS imaging technique with information entropy
NASA Astrophysics Data System (ADS)
Aoyagi, Satoka; Kawashima, Y.; Kudo, Masahiro
2005-05-01
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is capable of chemical imaging of proteins on insulated samples in principal. However, selection of specific peaks related to a particular protein, which are necessary for chemical imaging, out of numerous candidates had been difficult without an appropriate spectrum analysis technique. Therefore multivariate analysis techniques, such as principal component analysis (PCA), and analysis with mutual information defined by information theory, have been applied to interpret SIMS spectra of protein samples. In this study mutual information was applied to select specific peaks related to proteins in order to obtain chemical images. Proteins on insulated materials were measured with TOF-SIMS and then SIMS spectra were analyzed by means of the analysis method based on the comparison using mutual information. Chemical mapping of each protein was obtained using specific peaks related to each protein selected based on values of mutual information. The results of TOF-SIMS images of proteins on the materials provide some useful information on properties of protein adsorption, optimality of immobilization processes and reaction between proteins. Thus chemical images of proteins by TOF-SIMS contribute to understand interactions between material surfaces and proteins and to develop sophisticated biomaterials.
The medical ethics of Dr J Marion Sims: a fresh look at the historical record
Wall, L L
2006-01-01
Vesicovaginal fistula was a catastrophic complication of childbirth among 19th century American women. The first consistently successful operation for this condition was developed by Dr J Marion Sims, an Alabama surgeon who carried out a series of experimental operations on black slave women between 1845 and 1849. Numerous modern authors have attacked Sims's medical ethics, arguing that he manipulated the institution of slavery to perform ethically unacceptable human experiments on powerless, unconsenting women. This article reviews these allegations using primary historical source material and concludes that the charges that have been made against Sims are largely without merit. Sims's modern critics have discounted the enormous suffering experienced by fistula victims, have ignored the controversies that surrounded the introduction of anaesthesia into surgical practice in the middle of the 19th century, and have consistently misrepresented the historical record in their attacks on Sims. Although enslaved African American women certainly represented a “vulnerable population” in the 19th century American South, the evidence suggests that Sims's original patients were willing participants in his surgical attempts to cure their affliction—a condition for which no other viable therapy existed at that time. PMID:16731734
WholeCellSimDB: a hybrid relational/HDF database for whole-cell model predictions
Karr, Jonathan R.; Phillips, Nolan C.; Covert, Markus W.
2014-01-01
Mechanistic ‘whole-cell’ models are needed to develop a complete understanding of cell physiology. However, extracting biological insights from whole-cell models requires running and analyzing large numbers of simulations. We developed WholeCellSimDB, a database for organizing whole-cell simulations. WholeCellSimDB was designed to enable researchers to search simulation metadata to identify simulations for further analysis, and quickly slice and aggregate simulation results data. In addition, WholeCellSimDB enables users to share simulations with the broader research community. The database uses a hybrid relational/hierarchical data format architecture to efficiently store and retrieve both simulation setup metadata and results data. WholeCellSimDB provides a graphical Web-based interface to search, browse, plot and export simulations; a JavaScript Object Notation (JSON) Web service to retrieve data for Web-based visualizations; a command-line interface to deposit simulations; and a Python API to retrieve data for advanced analysis. Overall, we believe WholeCellSimDB will help researchers use whole-cell models to advance basic biological science and bioengineering. Database URL: http://www.wholecellsimdb.org Source code repository URL: http://github.com/CovertLab/WholeCellSimDB PMID:25231498
Dunleavy, Elaine M.; Pidoux, Alison L.; Monet, Marie; Bonilla, Carolina; Richardson, William; Hamilton, Georgina L.; Ekwall, Karl; McLaughlin, Paul J.; Allshire, Robin C.
2007-01-01
Summary A defining feature of centromeres is the presence of the histone H3 variant CENP-ACnp1. It is not known how CENP-ACnp1 is specifically delivered to, and assembled into, centromeric chromatin. Through a screen for factors involved in kinetochore integrity in fission yeast, we identified Sim3. Sim3 is homologous to known histone binding proteins NASPHuman and N1/N2Xenopus and aligns with Hif1S. cerevisiae, defining the SHNi-TPR family. Sim3 is distributed throughout the nucleoplasm, yet it associates with CENP-ACnp1 and also binds H3. Cells defective in Sim3 function have reduced levels of CENP-ACnp1 at centromeres (and increased H3) and display chromosome segregation defects. Sim3 is required to allow newly synthesized CENP-ACnp1 to accumulate at centromeres in S and G2 phase-arrested cells in a replication-independent mechanism. We propose that one function of Sim3 is to act as an escort that hands off CENP-ACnp1 to chromatin assembly factors, allowing its incorporation into centromeric chromatin. PMID:18158900
The Structured Inventory of Malingered Symptomatology (SIMS): a systematic review and meta-analysis.
van Impelen, Alfons; Merckelbach, Harald; Jelicic, Marko; Merten, Thomas
2014-01-01
We meta-analytically reviewed studies that used the Structured Inventory of Malingered Symptomatology (SIMS) to detect feigned psychopathology. We present weighted mean diagnostic accuracy and predictive power indices in various populations, based on 31 studies, including 61 subsamples and 4009 SIMS protocols. In addition, we provide normative data of patients, claimants, defendants, nonclinical adults, and various experimental feigners, based on 41 studies, including 125 subsamples and 4810 SIMS protocols. We conclude that the SIMS (1) is able to differentiate well between instructed feigners and honest responders; (2) generates heightened scores in groups that are known to have a raised prevalence of feigning (e.g., offenders who claim crime-related amnesia); (3) may overestimate feigning in patients who suffer from schizophrenia, intellectual disability, or psychogenic non-epileptic seizures; and (4) is fairly robust against coaching. The diagnostic power of the traditional cut scores of the SIMS (i.e., > 14 and > 16) is not so much limited by their sensitivity—which is satisfactory—but rather by their substandard specificity. This, however, can be worked around by combining the SIMS with other symptom validity measures and by raising the cut score, although the latter solution sacrifices sensitivity for specificity.
Sun, Li-Li; Zhou, Zhong-Jing; An, Li-Jun; An, Yan; Zhao, Yong-Qin; Meng, Xiao-Fang; Steele-King, Clare; Gan, Yin-Bo
2013-07-01
Arabidopsis trichomes are large branched single cells that protrude from the epidermis. The first morphological indication of trichome development is an increase in nuclear content resulting from an initial cycle of endoreduplication. Our previous study has shown that the C2H2 zinc finger protein GLABROUS INFLORESCENCE STEMS (GIS) is required for trichome initiation in the inflorescence organ and for trichome branching in response to gibberellic acid signaling, although GIS gene does not play a direct role in regulating trichome cell division. Here, we describe a novel role of GIS, controlling trichome cell division indirectly by interacting genetically with a key endoreduplication regulator SIAMESE (SIM). Our molecular and genetic studies have shown that GIS might indireclty control cell division and trichome branching by acting downstream of SIM. A loss of function mutation of SIM signficantly reduced the expression of GIS. Futhermore, the overexpression of GIS rescued the trichome cluster cell phenotypes of sim mutant. The gain or loss of function of GIS had no significant effect on the expression of SIM. These results suggest that GIS may play an indirect role in regulating trichome cell division by genetically interacting with SIM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Y.F.; Cai, W.; Zhang, J.X.
2000-04-03
The microstructural development inside the stress induced martensite (SIM) variants in Ti-Ni-Nb alloy with various degrees of deformation have been revealed by electron microscopic observations. The orientation relationship between the SIM and the parent phase has been found: [1{bar 1}0]{sub M}{parallel}[11{bar 1}]{sub B2}, (001){sub M} 5{degree} away from (101){sub B2}. The lattice invariant shear of the SIM variants at the slightly deformed stage is dominantly (11{bar 1}) Type I twin. Besides the ordinary slip, the adjustment and development of the internal secondary twinning from (11{bar 1}) Type I twin to {l_angle}011{r_angle} Type II/ or (011) Type I twin, (001)compound twinmore » and (111) Type I twin happen concurrently or in combination inside the SIM variants with the further deformation. The corresponding deformation mechanisms include stress induced reorientation of SIM substructural bands by the most favorably oriented twin system, stress induced migration of the SIM substructural boundary through internal twinning and stress induced injection of foreign SIM variant to the preexisting substructural bands.« less
The medical ethics of Dr J Marion Sims: a fresh look at the historical record.
Wall, L L
2006-06-01
Vesicovaginal fistula was a catastrophic complication of childbirth among 19th century American women. The first consistently successful operation for this condition was developed by Dr J Marion Sims, an Alabama surgeon who carried out a series of experimental operations on black slave women between 1845 and 1849. Numerous modern authors have attacked Sims's medical ethics, arguing that he manipulated the institution of slavery to perform ethically unacceptable human experiments on powerless, unconsenting women. This article reviews these allegations using primary historical source material and concludes that the charges that have been made against Sims are largely without merit. Sims's modern critics have discounted the enormous suffering experienced by fistula victims, have ignored the controversies that surrounded the introduction of anaesthesia into surgical practice in the middle of the 19th century, and have consistently misrepresented the historical record in their attacks on Sims. Although enslaved African American women certainly represented a "vulnerable population" in the 19th century American South, the evidence suggests that Sims's original patients were willing participants in his surgical attempts to cure their affliction-a condition for which no other viable therapy existed at that time.
The biological pump: Profiles of plankton production and consumption in the upper ocean
NASA Astrophysics Data System (ADS)
Longhurst, Alan R.; Glen Harrison, W.
The ‘biological pump’ mediates flux of carbon to the interior of the ocean by interctions between the components of the vertically-structured pelagic ecosystem of the photic zone. Chlorophyll profiles are not a simple indicator of autotrophic biomass or production, because of non-linearities in the physiology of cells and preferential vertical distribution of taxa. Profiles of numbers or biomass of heterotrophs do not correspond with profiles of consumption, because of depth-selection (taxa, seasons) for reasons unconnected with feeding. Depths of highest plant biomass, chlorophyll and growth rate coincide when these depths are shallow, but become progressively separated in profiles where they are deeper - so that highest growth rate lies progressively shallower than the chloropyll maximum. It is still uncertain how plant biomass is distributed in deep profiles. Depths of greatest heterotroph biomass (mesozooplankton) are usually close to depths of fastest plant growth rate, and thus lie shallower than the chlorophyll maximum in profiles where this itself is deep. This correlation is functional, and relates to the role of heterotrophs in excreting metabolic wastes (especially ammonia), which may fuel a significant component of integrated algal production, especially in the oligotrophic ocean. Some, but not all faecal material from mesozooplankton of the photic zone appears in vertical flux below the pycnocine, depending on the size of the source organisms, and the degree of vertical mixing above the pycnocline. Diel, but probably not seasonal, vertical migration is significant in the vertical flux of dissolved nitrogen. Regional generalisations of the vertical relations of the main components of the ‘biological pump’ now appear within reach, and an approach is suggested.
The Effect of Borehole Flow on Salinity Profiles From Deep Monitor Wells in Hawaii
NASA Astrophysics Data System (ADS)
Rotzoll, K.; Hunt, C. D.; El-Kadi, A. I.
2008-12-01
Ground-water resource management in Hawaii is based partly on salinity profiles from deep wells that are used to monitor the thickness of freshwater lenses and the transition zone between freshwater and saltwater. Vertical borehole flow in these wells may confound understanding of the actual salinity-depth profiles in the basaltic aquifers and lead to misinterpretations that hamper effective water-resource management. Causes and effects of borehole flow on salinity profiles are being evaluated at 40 deep monitor wells in Hawaii. Step- like changes in fluid electrical conductivity with respect to depth are indicative of borehole flow and are evident in almost all available salinity profiles. A regional trend in borehole flow direction, expected from basin-wide ground-water flow dynamics, is evident as major downward flow components in inland recharge areas and major upward flow components in discharge areas near the coast. The midpoint of the transition zone in one deep monitor well showed inconsequential depth displacements in response to barometric pressure and tidal fluctuations and to pumping from nearby wellfields. Commonly, the 1 mS/cm conductivity value is used to indicate the top of the transition zone. Contrary to the more stable midpoint, the depth of the 1 mS/cm conductivity value may be displaced by as much as 200 m in deep monitor wells near pumping wellfields. The displacement is complemented with an increase in conductivity at a particular depth in the upper part of the profile. The observed increase in conductivity is linear with increase in nearby pumpage. The largest deviations from expected aquifer-salinity profiles occur in deep monitor wells located in the area extending from east Pearl Harbor to Kalihi on Oahu, which coincides with the most heavily pumped part of the aquifer.
Schimmack, W; Schultz, W
2006-09-15
The temporal changes of the vertical distribution of (134)Cs (deposited by the Chernobyl fallout in 1986) and (137)Cs (deposited by the Chernobyl and the global fallout) in the soil were investigated at an undisturbed Bavarian grassland site in Germany. At ten sampling dates between 1986 and 2001, the activity density of (134)Cs and (137)Cs was determined in various soil layers down to 80 cm depth. In 2001, the small-scale spatial variability of the radiocaesium activity was determined by sampling five plots within 10 m(2) (coefficient of variation about 20% for the upper soil layers). Between 1987 and 1990, substantial changes of the activity-depth profiles were observed. The percentage depth distributions of (134)Cs and (137)Cs were rather similar. The 50%-depth of the accumulated activity increased from 2.4 cm in 1988 to 5.3 cm in 2001 for (134)Cs and from 2.7 to 5.8 cm for (137)Cs. This indicates that at the study site the migration data of Chernobyl-derived (137)Cs can be estimated by those of total (137)Cs. In the second part of this study, the activity-depth profiles will be evaluated by the convection-dispersion model [Schimmack, W, Feria Márquez, F. Migration of fallout radiocaesium in a grassland soil from 1986 to 2001. Part II: Evaluation of the activity-depth profiles by transport models. Sci Total Environ 2006-this issue].
A Computational Dual-Process Model of Social Interaction
2014-01-30
that portray the model’s behaviors when OMAR was adapted to operate first with Neverwinter Night and then with OpenSim . 3.1 Overview of Human...the Neverwinter Night (NwN; http://nwn.wikia.com) environment and more recently adapted to run with OpenSim (http://opensimulator.org). Figure 1...provides a screenshot of a scene from the NwN world while Figure 2 provides a screenshot from the OpenSim world. The NwN and OpenSim avatars and scenes
Bai, Ren; Wang, Jun-Tao; Deng, Ye; He, Ji-Zheng; Feng, Kai; Zhang, Li-Mei
2017-01-01
Paddy rice fields occupy broad agricultural area in China and cover diverse soil types. Microbial community in paddy soils is of great interest since many microorganisms are involved in soil functional processes. In the present study, Illumina Mi-Seq sequencing and functional gene array (GeoChip 4.2) techniques were combined to investigate soil microbial communities and functional gene patterns across the three soil types including an Inceptisol (Binhai), an Oxisol (Leizhou), and an Ultisol (Taoyuan) along four profile depths (up to 70 cm in depth) in mesocosm incubation columns. Detrended correspondence analysis revealed that distinctly differentiation in microbial community existed among soil types and profile depths, while the manifest variance in functional structure was only observed among soil types and two rice growth stages, but not across profile depths. Along the profile depth within each soil type, Acidobacteria, Chloroflexi, and Firmicutes increased whereas Cyanobacteria, β-proteobacteria, and Verrucomicrobia declined, suggesting their specific ecophysiological properties. Compared to bacterial community, the archaeal community showed a more contrasting pattern with the predominant groups within phyla Euryarchaeota, Thaumarchaeota, and Crenarchaeota largely varying among soil types and depths. Phylogenetic molecular ecological network (pMEN) analysis further indicated that the pattern of bacterial and archaeal communities interactions changed with soil depth and the highest modularity of microbial community occurred in top soils, implying a relatively higher system resistance to environmental change compared to communities in deeper soil layers. Meanwhile, microbial communities had higher connectivity in deeper soils in comparison with upper soils, suggesting less microbial interaction in surface soils. Structure equation models were developed and the models indicated that pH was the most representative characteristics of soil type and identified as the key driver in shaping both bacterial and archaeal community structure, but did not directly affect microbial functional structure. The distinctive pattern of microbial taxonomic and functional composition along soil profiles implied functional redundancy within these paddy soils. PMID:28611747
Bai, Ren; Wang, Jun-Tao; Deng, Ye; He, Ji-Zheng; Feng, Kai; Zhang, Li-Mei
2017-01-01
Paddy rice fields occupy broad agricultural area in China and cover diverse soil types. Microbial community in paddy soils is of great interest since many microorganisms are involved in soil functional processes. In the present study, Illumina Mi-Seq sequencing and functional gene array (GeoChip 4.2) techniques were combined to investigate soil microbial communities and functional gene patterns across the three soil types including an Inceptisol (Binhai), an Oxisol (Leizhou), and an Ultisol (Taoyuan) along four profile depths (up to 70 cm in depth) in mesocosm incubation columns. Detrended correspondence analysis revealed that distinctly differentiation in microbial community existed among soil types and profile depths, while the manifest variance in functional structure was only observed among soil types and two rice growth stages, but not across profile depths. Along the profile depth within each soil type, Acidobacteria , Chloroflexi , and Firmicutes increased whereas Cyanobacteria , β -proteobacteria , and Verrucomicrobia declined, suggesting their specific ecophysiological properties. Compared to bacterial community, the archaeal community showed a more contrasting pattern with the predominant groups within phyla Euryarchaeota , Thaumarchaeota , and Crenarchaeota largely varying among soil types and depths. Phylogenetic molecular ecological network (pMEN) analysis further indicated that the pattern of bacterial and archaeal communities interactions changed with soil depth and the highest modularity of microbial community occurred in top soils, implying a relatively higher system resistance to environmental change compared to communities in deeper soil layers. Meanwhile, microbial communities had higher connectivity in deeper soils in comparison with upper soils, suggesting less microbial interaction in surface soils. Structure equation models were developed and the models indicated that pH was the most representative characteristics of soil type and identified as the key driver in shaping both bacterial and archaeal community structure, but did not directly affect microbial functional structure. The distinctive pattern of microbial taxonomic and functional composition along soil profiles implied functional redundancy within these paddy soils.
Technical note: GODESS - a profiling mooring in the Gotland Basin
NASA Astrophysics Data System (ADS)
Prien, Ralf D.; Schulz-Bull, Detlef E.
2016-07-01
This note describes a profiling mooring with an interdisciplinary suite of sensors taking profiles between 180 and 30 m depth. It consists of an underwater winch, moored below 180 m depth, and a profiling instrumentation platform. In its described setup it can take about 200 profiles at pre-programmed times or intervals with one set of batteries. This allows for studies over an extended period of time (e.g. two daily profiles over a time of 3 months). The Gotland Deep Environmental Sampling Station (GODESS) in the Eastern Gotland Basin of the Baltic Sea is aimed at investigations of redoxcline dynamics. The described system can be readily adapted to other research foci by changing the profiling instrumentation platform and its payload.
Selectivity of silica species in ocean observed from seasonal and local changes
NASA Astrophysics Data System (ADS)
Tanaka, Miho; Takahashi, Kazuya; Nemoto, Masao; Horimoto, Naho
2013-03-01
Silicic acids, derived from SiO2 (silica), have several chemical forms in solution. Silica is a nutrient for diatoms, which are phytoplankton in oceans. Silica species can be used as a tracer to examine the behavior of silica in nature. The speciation for silica by FAB-MS (fast atom bombardment mass spectrometry) has been carried out for seawater samples from Tokyo Bay and Sagami Bay to investigate the seasonal and locational changes of the depth profiles of silica species. The species, [Si(OH)2O2Na+]-, [Si2(OH)5O2]- ([dimer]-), [Si2(OH)4O3Na+]-, [Si(OH)7O5-] ([cyclic tetramer]-), [Si4(OH)6O6Na+]-, [Si(OH)9O]- ([linear tetramer]-) and [Si4(OH)8O5Na+]- were mainly identified by FAB-MS. The seasonal and locational changes and the reproducibility of depth profiles of silica species were determined from October 2001 to July 2002. The depth profile of the ratio of linear tetramer to cyclic tetramer reflects the activity of diatoms, implying that the linear tetramer is the preferred "food" for diatoms. In particular, the depth profile for the ratio of linear tetramer to cyclic tetramer exhibits a critical changes that depend on the season. Furthermore, the depth profiles for the samples from Sagami Bay (open ocean) indicate that seawater is easily exchanged by ocean currents (the Japan Current). Thus, silica speciation by FAB-MS can give us a new tracer indicating the characteristics of the seawater budget, which change with depth, season and ocean locality.
Ham, Nam Seok; Jang, Jae Young; Ryu, Sung Woo; Kim, Ji Hye; Park, Eui Ju; Lee, Woong Cheul; Shim, Kwang Yeun; Jeong, Soung Won; Kim, Hyun Gun; Lee, Tae Hee; Jeon, Sung Ran; Cho, Jun Hyung; Cho, Joo Young; Jin, So Young; Lee, Ji Sung
2013-11-07
To determine whether magnified observation of short-segment Barrett's esophagus (BE) is useful for the detection of specialized intestinal metaplasia (SIM). Thirty patients with suspected short-segment BE underwent magnifying endoscopy up to × 80. The magnified images were analyzed with respect to their pit-patterns, which were simultaneously classified into five epithelial types [I (small round), II (straight), III (long oval), IV (tubular), V (villous)] by Endo's classification. Then, a 0.5% solution of methylene blue (MB) was sprayed over columnar mucosa. The patterns of the magnified image and MB staining were analyzed. Biopsies were obtained from the regions previously observed by magnifying endoscopy and MB chromoendoscopy. Three of five patients with a type V (villous) epithelial pattern had SIM, whereas 21 patients with a non-type V epithelial patterns did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of pit-patterns in detecting SIM were 100%, 91.3%, 92.3%, 60% and 100%, respectively (P = 0.004). Three of the 12 patients with positive MB staining had SIM, whereas 14 patients with negative MB staining did not have SIM. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of MB staining in detecting SIM were 100%, 60.9%, 65.4%, 25% and 100%, respectively (P = 0.085). The specificity and accuracy of pit-pattern evaluation were significantly superior compared with MB staining for detecting SIM by comparison with the exact McNemar's test (P = 0.0391). The magnified observation of a short-segment BE according to the mucosal pattern and its classification can be predictive of SIM.
Astrometric Planet Searches with SIM PlanetQuest
NASA Technical Reports Server (NTRS)
Beichman, Charles A.; Unwin, Stephen C.; Shao, Michael; Tanner, Angelle M.; Catanzarite, Joseph H.; March, Geoffrey W.
2007-01-01
SIM will search for planets with masses as small as the Earth's orbiting in the habitable zones' around more than 100 of the stars and could discover many dozen if Earth-like planets are common. With a planned 'Deep Survey' of 100-450 stars (depending on desired mass sensitivity) SIM will search for terrestrial planets around all of the candidate target stars for future direct detection missions such as Terrestrial Planet Finder and Darwin, SIM's 'Broad Survey' of 2010 stars will characterize single and multiple-planet systems around a wide variety of stellar types, including many now inaccessible with the radial velocity technique. In particular, SIM will search for planets around young stars providing insights into how planetary systems are born and evolve with time.
Imaging of arsenic traces in human hair by nano-SIMS 50
NASA Astrophysics Data System (ADS)
Audinot, J.-N.; Schneider, S.; Yegles, M.; Hallegot, P.; Wennig, R.; Migeon, H.-N.
2004-06-01
The nano-SIMS 50 allows ion imaging to be performed on microtomed hair cross-sections in order to determine the concentration and to localize the distribution of arsenic traces in hairs. Our study shows a linear relationship between the SIMS signal (As normalized with respect to CN) and the concentration determined by other analytical techniques. The advantages of SIMS imaging can be clearly proved by the capability to record quantitative distributions of As in the cross section. As a matter of fact, the nano-SIMS 50 images may allow differentiation between As located in the medulla, the cortex and the cuticle of the hair and thus distinguish between intoxication by indigestion and surface pollution of the sample.
IET. Control and equipment building (TAN620) sections. Depth and profile ...
IET. Control and equipment building (TAN-620) sections. Depth and profile of earthen shield tunnels. Ralph M. Parsons 902-4-ANP-620-A-321. Date: February 1954. INEEL index code no. 035-0620-00-693-106906 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Young, Stuart A.; Josset, Damien B.; Vaughan, Mark A.
2010-01-01
CALIPSO's (Cloud Aerosol Lidar Infrared Pathfinder Satellite Observations) analysis algorithms generally require the use of tabulated values of the lidar ratio in order to retrieve aerosol extinction and optical depth from measured profiles of attenuated backscatter. However, for any given time or location, the lidar ratio for a given aerosol type can differ from the tabulated value. To gain some insight as to the extent of the variability, we here calculate the lidar ratio for dust aerosols using aerosol optical depth constraints from two sources. Daytime measurements are constrained using Level 2, Collection 5, 550-nm aerosol optical depth measurements made over the ocean by the MODIS (Moderate Resolution Imaging Spectroradiometer) on board the Aqua satellite, which flies in formation with CALIPSO. We also retrieve lidar ratios from night-time profiles constrained by aerosol column optical depths obtained by analysis of CALIPSO and CloudSat backscatter signals from the ocean surface.
Tri, Tran Manh; Anh, Hoang Quoc; Tham, Trinh Thi; Van Quy, Tran; Long, Nguyen Quang; Nhung, Dao Thi; Nakamura, Masafumi; Nishida, Masayo; Maeda, Yasuaki; Van Boi, Luu; Minh, Tu Binh
2016-05-15
Concentrations of PCBs and OCPs were measured in 35 surface sediment samples collected from offshore waters of Central Vietnam. The mean concentrations of PCBs, HCHs, and DDTs in surface sediments were 86.5, 37.0, and 44.5pgg(-1), respectively. Additionally, nine PCDDs, eleven PCDFs, and twelve dl-PCBs were also examined in 19 sediment core samples collected from five locations. Concentration of PCDDs, PCDFs, and dl-PCBs ranged from 200 to 460, 0.39 to 2.9, and 1.6 to 22pgg(-1), respectively. OCDD was detected at the highest concentration, ranged from 100 to 300pgg(-1). Generally, the concentrations of PCDD/Fs at shallower depths were higher, meanwhile the depth profiles of dl-PCBs in sediment cores were different than the depth profiles of PCDD/Fs. The results suggest that the pollution of PCBs might be from many different sources leading to the variation between depths. Copyright © 2016 Elsevier Ltd. All rights reserved.
Subcellular boron and fluorine distributions with SIMS ion microscopy in BNCT and cancer research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Subhash Chandra
2008-05-30
The development of a secondary ion mass spectrometry (SIMS) based technique of Ion Microscopy in boron neutron capture therapy (BNCT) was the main goal of this project, so that one can study the subcellular location of boron-10 atoms and their partitioning between the normal and cancerous tissue. This information is fundamental for the screening of boronated drugs appropriate for neutron capture therapy of cancer. Our studies at Cornell concentrated mainly on studies of glioblastoma multiforme (GBM). The early years of the grant were dedicated to the development of cryogenic methods and correlative microscopic approaches so that a reliable subcellular analysismore » of boron-10 atoms can be made with SIMS. In later years SIMS was applied to animal models and human tissues of GBM for studying the efficacy of potential boronated agents in BNCT. Under this grant the SIMS program at Cornell attained a new level of excellence and collaborative SIMS studies were published with leading BNCT researchers in the U.S.« less
Melo, Cristiane Magalhães de; Bevilacqua, Paula Dias; Barletto, Marisa; França, Elisabeth Barboza
2014-09-01
This study aimed to assess the quality of data on deaths from external causes in Viçosa, Minas Gerais State, Brazil, from 2000 to 2009, and the completeness of the Mortality Information System (SIM). The data were obtained from the SIM of the Municipal Health Department, municipal police enquiries, and local newspaper articles, resulting in a databank with 495 deaths from external causes. The results showed a high proportion of deaths with indeterminate intent (21%) in the SIM, suggesting problems with quality of information. Comparison of data from the SIM and police department detected problems with coverage in the SIM (21%) and thus in the official statistics on mortality from accidents and violence. The results emphasize the importance of searches in other data sources to upgrade the SIM and expand its coverage, and especially the need for studies to identify and analyze problems faced by small and medium-sized cities in the production of mortality data.
Graphene Oxide as a Novel Evenly Continuous Phase Matrix for TOF-SIMS.
Cai, Lesi; Sheng, Linfeng; Xia, Mengchan; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong; Chen, Hongyuan
2017-03-01
Using matrix to enhance the molecular ion signals for biomolecule identification without loss of spatial resolution caused by matrix crystallization is a great challenge for the application of TOF-SIMS in real-world biological research. In this report, graphene oxide (GO) was used as a matrix for TOF-SIMS to improve the secondary ion yields of intact molecular ions ([M + H] + ). Identifying and distinguishing the molecular ions of lipids (m/z >700) therefore became straightforward. The spatial resolution of TOF-SIMS imaging could also be improved as GO can form a homogeneous layer of matrix instead of crystalline domain, which prevents high spatial resolution in TOF-SIMS imaging. Lipid mapping in presence of GO revealed the delicate morphology and distribution of single vesicles with a diameter of 800 nm. On GO matrix, the vesicles with similar shape but different chemical composition could be distinguished using molecular ions. This novel matrix holds potentials in such applications as the analysis and imaging of complex biological samples by TOF-SIMS. Graphical Abstract ᅟ.
Graphene Oxide as a Novel Evenly Continuous Phase Matrix for TOF-SIMS
NASA Astrophysics Data System (ADS)
Cai, Lesi; Sheng, Linfeng; Xia, Mengchan; Li, Zhanping; Zhang, Sichun; Zhang, Xinrong; Chen, Hongyuan
2017-03-01
Using matrix to enhance the molecular ion signals for biomolecule identification without loss of spatial resolution caused by matrix crystallization is a great challenge for the application of TOF-SIMS in real-world biological research. In this report, graphene oxide (GO) was used as a matrix for TOF-SIMS to improve the secondary ion yields of intact molecular ions ([M + H]+). Identifying and distinguishing the molecular ions of lipids ( m/z >700) therefore became straightforward. The spatial resolution of TOF-SIMS imaging could also be improved as GO can form a homogeneous layer of matrix instead of crystalline domain, which prevents high spatial resolution in TOF-SIMS imaging. Lipid mapping in presence of GO revealed the delicate morphology and distribution of single vesicles with a diameter of 800 nm. On GO matrix, the vesicles with similar shape but different chemical composition could be distinguished using molecular ions. This novel matrix holds potentials in such applications as the analysis and imaging of complex biological samples by TOF-SIMS.
CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry.
Tian, Hua; Maciążek, Dawid; Postawa, Zbigniew; Garrison, Barbara J; Winograd, Nicholas
2016-09-01
The emergence of argon-based gas cluster ion beams for SIMS experiments opens new possibilities for molecular depth profiling and 3D chemical imaging. These beams generally leave less surface chemical damage and yield mass spectra with reduced fragmentation compared with smaller cluster projectiles. For nanoscale bioimaging applications, however, limited sensitivity due to low ionization probability and technical challenges of beam focusing remain problematic. The use of gas cluster ion beams based upon systems other than argon offer an opportunity to resolve these difficulties. Here we report on the prospects of employing CO2 as a simple alternative to argon. Ionization efficiency, chemical damage, sputter rate, and beam focus are investigated on model compounds using a series of CO2 and Ar cluster projectiles (cluster size 1000-5000) with the same mass. The results show that the two projectiles are very similar in each of these aspects. Computer simulations comparing the impact of Ar2000 and (CO2)2000 on an organic target also confirm that the CO2 molecules in the cluster projectile remain intact, acting as a single particle of m/z 44. The imaging resolution employing CO2 cluster projectiles is improved by more than a factor of two. The advantage of CO2 versus Ar is also related to the increased stability which, in addition, facilitates the operation of the gas cluster ion beams (GCIB) system at lower backing pressure. Graphical Abstract ᅟ.
Suppression effect of silicon (Si) on Er{sup 3+} 1.54μm excitation in ZnO thin films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Bo; Lu, Fei, E-mail: lufei@sdu.edu.cn; Fan, Ranran
2016-08-15
We have investigated the photoluminescence (PL) characteristics of ZnO:Er thin films on Si (100) single crystal and SiO{sub 2}-on-silicon (SiO{sub 2}) substrates, synthesized by radio frequency magnetron sputtering. Rutherford backscattering/channeling spectrometry (RBS), X-ray diffraction (XRD) and atomic force microscope (AFM) were used to analyze the properties of thin films. The diffusion depth profiles of Si were determined by second ion mass spectrometry (SIMS). Infrared spectra were obtained from the spectrometer and related instruments. Compared with the results at room temperature (RT), PL (1.54μm) intensity increased when samples were annealed at 250°C and decreased when at 550°C. A new peak atmore » 1.15μm from silicon (Si) appeared in 550°C samples. The Si dopants in ZnO film, either through the diffusion of Si from the substrate or ambient, directly absorbed the energy of pumping light and resulted in the suppression of Er{sup 3+} 1.54μm excitation. Furthermore, the energy transmission efficiency between Si and Er{sup 3+} was very low when compared with silicon nanocrystal (Si-NC). Both made the PL (1.54μm) intensity decrease. All the data in experiments proved the negative effects of Si dopants on PL at 1.54μm. And further research is going on.« less
NASA Astrophysics Data System (ADS)
McGillivray, G. W.; Geeson, D. A.; Greenwood, R. C.
1994-01-01
The rate of oxidation of uranium metal by moist air has been measured at temperatures from 115 to 350°C and water vapour pressures from 0 to 47 kPa (350 Torr). From this and from previously reported data, a model has been developed which allows the rate of uranium oxidation to be calculated at any particular combination of temperature and water vapour pressure of interest, in the range 0-350°C and 0-101.3 kPa (760 Torr). The model is based on the assumption that the surface concentration of water determines the rate of reaction and that the adsorption of water onto the oxide follows a Langmuir type isotherm. Theoretical plots of rate as a function of water vapour pressure and Arrhenius plots derived from the model have been shown to be in good agreement with experimental data. The model assumes separate contributions to the overall observed rate from oxygen and water vapour. Surface studies have been carried out using SIMS (secondary ion mass spectrometry). Depth profiling of the oxide produced by isotopically labelled reagents ( 18O 2 and H 218O), has shown that oxygen from both reactants is incorporated into the oxide layer in the ratio predicted by the kinetic model. This supports a mechanism in which oxygen and water vapour produce separate diffusing species (possibly O 2- and OH -).
Kulkarni, Mukta; Mazare, Anca; Park, Jung; Gongadze, Ekaterina; Killian, Manuela Sonja; Kralj, Slavko; von der Mark, Klaus; Iglič, Aleš; Schmuki, Patrik
2016-11-01
In the present work we investigate the key factors involved in the interaction of small-sized charged proteins with TiO 2 nanostructures, i.e. albumin (negatively charged), histone (positively charged). We examine anodic nanotubes with specific morphology (simultaneous control over diameter and length, e.g. diameter - 15, 50 or 100nm, length - 250nm up to 10μm) and nanopores. The nanostructures surface area has a direct influence on the amount of bound protein, nonetheless the protein physical properties as electric charge and size (in relation to nanotopography and biomaterial's electric charge) are crucial too. The highest quantity of adsorbed protein is registered for histone, for 100nm diameter nanotubes (10μm length) while higher values are registered for 15nm diameter nanotubes when normalizing protein adsorption to nanostructures' surface unit area (evaluated from dye desorption measurements) - consistent with theoretical considerations. The proteins presence on the nanostructures is evaluated by XPS and ToF-SIMS; additionally, we qualitatively assess their presence along the nanostructures length by ToF-SIMS depth profiles, with decreasing concentration towards the bottom. Surface nanostructuring of titanium biomedical devices with TiO 2 nanotubes was shown to significantly influence the adhesion, proliferation and differentiation of mesenchymal stem cells (and other cells too). A high level of control over the nanoscale topography and over the surface area of such 1D nanostructures enables a direct influence on protein adhesion. Herein, we investigate and show how the nanostructure morphology (nanotube diameter and length) influences the interactions with small-sized charged proteins, using as model proteins bovine serum albumin (negatively charged) and histone (positively charged). We show that the protein charge strongly influences their adhesion to the TiO 2 nanostructures. Protein adhesion is quantified by ELISA measurements and determination of the nanostructures' total surface area. We use a quantitative surface charge model to describe charge interactions and obtain an increased magnitude of the surface charge density at the top edges of the nanotubes. In addition, we track the proteins presence on and inside the nanostructures. We believe that these aspects are crucial for applications where the incorporation of active molecules such as proteins, drugs, growth factors, etc., into nanotubes is desired. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Estimation of skin concentrations of topically applied lidocaine at each depth profile.
Oshizaka, Takeshi; Kikuchi, Keisuke; Kadhum, Wesam R; Todo, Hiroaki; Hatanaka, Tomomi; Wierzba, Konstanty; Sugibayashi, Kenji
2014-11-20
Skin concentrations of topically administered compounds need to be considered in order to evaluate their efficacies and toxicities. This study investigated the relationship between the skin permeation and concentrations of compounds, and also predicted the skin concentrations of these compounds using their permeation parameters. Full-thickness skin or stripped skin from pig ears was set on a vertical-type diffusion cell, and lidocaine (LID) solution was applied to the stratum corneum (SC) in order to determine in vitro skin permeability. Permeation parameters were obtained based on Fick's second law of diffusion. LID concentrations at each depth of the SC were measured using tape-stripping. Concentration-depth profiles were obtained from viable epidermis and dermis (VED) by analyzing horizontal sections. The corresponding skin concentration at each depth was calculated based on Fick's law using permeation parameters and then compared with the observed value. The steady state LID concentrations decreased linearly as the site became deeper in SC or VED. The calculated concentration-depth profiles of the SC and VED were almost identical to the observed profiles. The compound concentration at each depth could be easily predicted in the skin using diffusion equations and skin permeation data. Thus, this method was considered to be useful for promoting the efficient preparation of topically applied drugs and cosmetics. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hobley, Eleanor; Kriegs, Stefanie; Steffens, Markus
2017-04-01
Obtaining reliable and accurate data regarding the spatial distribution of different soil components is difficult due to issues related with sampling scale and resolution on the one hand and laboratory analysis on the other. When investigating the chemical composition of soil, studies frequently limit themselves to two dimensional characterisations, e.g. spatial variability near the surface or depth distribution down the profile, but rarely combine both approaches due to limitations to sampling and analytical capacities. Furthermore, when assessing depth distributions, samples are taken according to horizon or depth increments, resulting in a mixed sample across the sampling depth. Whilst this facilitates mean content estimation per depth increment and therefore reduces analytical costs, the sample information content with regards to heterogeneity within the profile is lost. Hyperspectral imaging can overcome these sampling limitations, yielding high resolution spectral data of down the soil profile, greatly enhancing the information content of the samples. This can then be used to augment horizontal spatial characterisation of a site, yielding three dimensional information into the distribution of spectral characteristics across a site and down the profile. Soil spectral characteristics are associated with specific chemical components of soil, such as soil organic matter or iron contents. By correlating the content of these soil components with their spectral behaviour, high resolution multi-dimensional analysis of soil chemical composition can be obtained. Here we present a hyperspectral approach to the characterisation of soil organic matter and iron down different soil profiles, outlining advantages and issues associated with the methodology.
Imaging Mass Spectrometry on the Nanoscale with Cluster Ion Beams
Winograd, Nicholas
2014-12-02
Imaging with cluster secondary ion mass spectrometry (SIMS) is reaching a mature level of development. When, using a variety of molecular ion projectiles to stimulate desorption, 3-dimensional imaging with the selectivity of mass spectrometry can now be achieved with submicrometer spatial resolution and <10 nm depth resolution. In this Perspective, stock is taken regarding what it will require to routinely achieve these remarkable properties. Some issues include the chemical nature of the projectile, topography formation, differential erosion rates, and perhaps most importantly, ionization efficiency. Shortcomings of existing instrumentation are also noted. One key part of this discussion involves speculation onmore » how best to resolve these issues.« less
Imaging Mass Spectrometry on the Nanoscale with Cluster Ion Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winograd, Nicholas
Imaging with cluster secondary ion mass spectrometry (SIMS) is reaching a mature level of development. When, using a variety of molecular ion projectiles to stimulate desorption, 3-dimensional imaging with the selectivity of mass spectrometry can now be achieved with submicrometer spatial resolution and <10 nm depth resolution. In this Perspective, stock is taken regarding what it will require to routinely achieve these remarkable properties. Some issues include the chemical nature of the projectile, topography formation, differential erosion rates, and perhaps most importantly, ionization efficiency. Shortcomings of existing instrumentation are also noted. One key part of this discussion involves speculation onmore » how best to resolve these issues.« less
Methodological development of topographic correction in 2D/3D ToF-SIMS images using AFM images
NASA Astrophysics Data System (ADS)
Jung, Seokwon; Lee, Nodo; Choi, Myungshin; Lee, Jungmin; Cho, Eunkyunng; Joo, Minho
2018-02-01
Time-of-flight secondary-ion mass spectrometry (ToF-SIMS) is an emerging technique that provides chemical information directly from the surface of electronic materials, e.g. OLED and solar cell. It is very versatile and highly sensitive mass spectrometric technique that provides surface molecular information with their lateral distribution as a two-dimensional (2D) molecular image. Extending the usefulness of ToF-SIMS, a 3D molecular image can be generated by acquiring multiple 2D images in a stack. These imaging techniques by ToF-SIMS provide an insight into understanding the complex structures of unknown composition in electronic material. However, one drawback in ToF-SIMS is not able to represent topographical information in 2D and 3D mapping images. To overcome this technical limitation, topographic information by ex-situ technique such as atomic force microscopy (AFM) has been combined with chemical information from SIMS that provides both chemical and physical information in one image. The key to combine two different images obtained from ToF-SIMS and AFM techniques is to develop the image processing algorithm, which performs resize and alignment by comparing the specific pixel information of each image. In this work, we present methodological development of the semiautomatic alignment and the 3D structure interpolation system for the combination of 2D/3D images obtained by ToF-SIMS and AFM measurements, which allows providing useful analytical information in a single representation.
Sperl-Hillen, JoAnn; O'Connor, Patrick J; Ekstrom, Heidi L; Rush, William A; Asche, Stephen E; Fernandes, Omar D; Appana, Deepika; Amundson, Gerald H; Johnson, Paul E; Curran, Debra M
2014-12-01
To test a virtual case-based Simulated Diabetes Education intervention (SimDE) developed to teach primary care residents how to manage diabetes. Nineteen primary care residency programs, with 341 volunteer residents in all postgraduate years (PGY), were randomly assigned to a SimDE intervention group or control group (CG). The Web-based interactive educational intervention used computerized virtual patients who responded to provider actions through programmed simulation models. Eighteen distinct learning cases (L-cases) were assigned to SimDE residents over six months from 2010 to 2011. Impact was assessed using performance on four virtual assessment cases (A-cases), an objective knowledge test, and pre-post changes in self-assessed diabetes knowledge and confidence. Group comparisons were analyzed using generalized linear mixed models, controlling for clustering of residents within residency programs and differences in baseline knowledge. The percentages of residents appropriately achieving A-case composite clinical goals for glucose, blood pressure, and lipids were as follows: A-case 1: SimDE = 21.2%, CG = 1.8%, P = .002; A-case 2: SimDE = 15.7%, CG = 4.7%, P = .02; A-case 3: SimDE = 48.0%, CG = 10.4%, P < .001; and A-case 4: SimDE = 42.1%, CG = 18.7%, P = .004. The mean knowledge score and pre-post changes in self-assessed knowledge and confidence were significantly better for SimDE group than CG participants. A virtual case-based simulated diabetes education intervention improved diabetes management skills, knowledge, and confidence for primary care residents.
Chini, Corryn E; Fisher, Gregory L; Johnson, Ben; Tamkun, Michael M; Kraft, Mary L
2018-02-26
Advances in three-dimensional secondary ion mass spectrometry (SIMS) imaging have enabled visualizing the subcellular distributions of various lipid species within individual cells. However, the difficulty of locating organelles using SIMS limits efforts to study their lipid compositions. Here, the authors have assessed whether endoplasmic reticulum (ER)-Tracker Blue White DPX ® , which is a commercially available stain for visualizing the endoplasmic reticulum using fluorescence microscopy, produces distinctive ions that can be used to locate the endoplasmic reticulum using SIMS. Time-of-flight-SIMS tandem mass spectrometry (MS 2 ) imaging was used to identify positively and negatively charged ions produced by the ER-Tracker stain. Then, these ions were used to localize the stain and thus the endoplasmic reticulum, within individual human embryonic kidney cells that contained higher numbers of endoplasmic reticulum-plasma membrane junctions on their surfaces. By performing MS 2 imaging of selected ions in parallel with the precursor ion (MS 1 ) imaging, the authors detected a chemical interference native to the cell at the same nominal mass as the pentafluorophenyl fragment from the ER-Tracker stain. Nonetheless, the fluorine secondary ions produced by the ER-Tracker stain provided a distinctive signal that enabled locating the endoplasmic reticulum using SIMS. This simple strategy for visualizing the endoplasmic reticulum in individual cells using SIMS could be combined with existing SIMS methodologies for imaging intracellular lipid distribution and to study the lipid composition within the endoplasmic reticulum.
Medina, Sonia; Collado-González, Jacinta; Ferreres, Federico; Londoño-Londoño, Julián; Jiménez-Cartagena, Claudio; Guy, Alexandre; Durand, Thierry; Galano, Jean-Marie; Gil-Izquierdo, Angel
2017-08-15
The genus Passiflora, comprising about 500 species, is the largest in the Passion flower family. Passiflora edulis Sims f. edulis (gulupa) is one of the most important fruits cultivated in Colombia. In recent years and due to its organoleptic and bioactive properties, its exports have significantly increased. In this work, six new bioactive oxylipins -phytoprostanes - were detected in gulupa shell by a UHPLC-QqQ-MS/MS method: F 1t -phytoprostanes and D 1t -phytoprostanes were the predominant and minor classes, respectively. Moreover, the polyphenol profile of the shell was investigated and we were able to detect and quantify phenolic compounds that have not been described previously, like luteolin-8-C-(2-O-rhamnosyl)hexoside and quercetin-3-O-(6″-acetyl)glucosyl-2″-sinapic acid. Consequently, this study provides new insights into the importance of gulupa shell as a valuable option in the design of new beverages rich in antioxidant phytochemicals, as part of a well-balanced diet, and in the process and quality control of such products. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rosmarinic acid content in antidiabetic aqueous extract of Ocimum canum sims grown in Ghana.
Berhow, Mark A; Affum, Andrews Obeng; Gyan, Ben A
2012-07-01
Rosmarinic acid (RA) is an important antioxidant polyphenol that is found in a variety of spices and herbs, including Ocimum canum Sims (locally called eme or akokobesa in Ghana). Aqueous extracts from the leaves of O. canum are used as an antidiabetic herbal medicine in Ghana. Analytical thin-layer chromatography was used to examine the composition of the polyphenols in leaf extracts. The polyphenol content in the aqueous and methanol extracts from the leaf, as determined by the Folin-Ciocalteu method, were 314 and 315 mg gallic acid equivalent/g leaf sample, respectively. The total flavonoid concentration as determined by the aluminum(III) chloride method was 135 mg catechin equivalent/g leaf sample. High-performance liquid chromatography coupled to an electrospray Quadrupole time-of-flight mass spectrometer was also used to determine the polyphenol fingerprint profile in the leaf extracts of O. canum. Although the average RA concentration in the O. canum leaf extracts from Ghana was 1.69 mg/g dry weight (reported values range from 0.01 to 99.62 mg/g dry weight), this polyphenol was still a prominent peak in addition to caffeic acid derivatives.
Ruiz-Samblás, C; González-Casado, A; Cuadros-Rodríguez, L; García, F P Rodríguez
2010-06-30
The analysis of the triacylglycerol (TAG) composition of oils is a very challenging task, since the TAGs have very similar physico-chemical properties. In this work, a high temperature-gas chromatographic method coupled to electron ionization-mass spectrometry (HT-GC/EI-MS), in the Selected Ion Monitoring (SIM) mode, method was developed for the analysis of TAGs in the olive oil; this is a method suitable for routine analysis. This method was developed using commercially available standard TAGs. The TAGs studied were separated according to their equivalent carbon number and degree of unsaturation. The peak assignment was carried out by locating the characteristic fragment ions having the same retention time on the SIM profile such as [RCO+74](+) and [RCO+128](+) ions, due to the fatty acyl residues on sn-1, sn-2 and sn-3 positions of the TAG molecule and the [M-OCOR](+) ions corresponding to the acyl ions. The developed method was very useful to eliminate the interferences that appeared in the mass spectrum since electron ionization can prevent satisfactory interpretation of spectra. Copyright 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Dawson, K.; Scheller, S.; Dillon, J. G.; Orphan, V. J.
2016-12-01
Stable isotope probing (SIP) is a valuable tool for gaining insights into ecophysiology and biogeochemical cycling of environmental microbial communities by tracking isotopically labeled compounds into cellular macromolecules as well as into byproducts of respiration. SIP, in conjunction with nanoscale secondary ion mass spectrometry (NanoSIMS), allows for the visualization of isotope incorporation at the single cell level. In this manner, both active cells within a diverse population as well as heterogeneity in metabolism within a homogeneous population can be observed. The ecophysiological implications of these single cell stable isotope measurements are often limited to the taxonomic resolution of paired fluorescence in situ hybridization (FISH) microscopy. Here we introduce a taxonomy-independent method using multi-isotope SIP and NanoSIMS for identifying and grouping phenotypically similar microbial cells by their chemical and isotopic fingerprint. This method was applied to SIP experiments in a sulfur-cycling biofilm collected from sulfidic intertidal vents amended with 13C-acetate, 15N-ammonium, and 33S-sulfate. Using a cluster analysis technique based on fuzzy c-means to group cells according to their isotope (13C/12C, 15N/14N, and 33S/32S) and elemental ratio (C/CN and S/CN) profiles, our analysis partitioned 2200 cellular regions of interest (ROIs) into 5 distinct groups. These isotope phenotype groupings are reflective of the variation in labeled substrate uptake by cells in a multispecies metabolic network dominated by Gamma- and Deltaproteobacteria. Populations independently grouped by isotope phenotype were subsequently compared with paired FISH data, demonstrating a single coherent deltaproteobacterial cluster and multiple gammaproteobacterial groups, highlighting the distinct ecophysiologies of spatially-associated microbes within the sulfur-cycling biofilm from White Point Beach, CA.
NASA Astrophysics Data System (ADS)
Granskog, Mats A.; MacDonald, Robie W.; Kuzyk, Zou Zou A.; Senneville, Simon; Mundy, Christopher-John; Barber, David G.; Stern, Gary A.; Saucier, Francois
2009-08-01
Distributions of freshwater (sea-ice melt and runoff) were investigated along inshore-offshore sections in southwestern Hudson Bay for fall conditions. Conductivity-temperature-density profiles and bottle samples collected for salinity, oxygen isotope (δ18O), and colored dissolved organic matter (CDOM) analyses were used to discriminate between contributions of river water (RW) and sea-ice melt (SIM). Stations had a fresh summer surface mixed layer 5-25 m thick overlying a cold subsurface layer indicative of the previous winter's polar mixed layer (PML). The fraction of RW decreased strongly with distance from shore, while the opposite was true for SIM. The majority of RW was constrained in a coastal domain within 100-150 km from shore, which, because of high alongshore velocities, accounts for the majority of freshwater and volume transports. On the basis of freshwater inventories and composition, brine and RW accumulate in the PML over winter because of ice formation and downward mixing. The summer surface circulation results in an annual net export of SIM from the region. Residence times for freshwater components in the southwestern sector of the bay, based on currents derived from a 3-D ocean model for Hudson Bay, are about 1-10 months, implying rapid transit of freshwater. Despite the short residence time for RW (1-3 months), CDOM is significantly photobleached and provides an unreliable tracer for RW. Photobleaching represents an important sink for dissolved organic carbon entering from rivers and could, in part, explain why Hudson Bay is only a minor sink for atmospheric CO2 in the open water season.
Dawson, Katherine S.; Scheller, Silvan; Dillon, Jesse G.; Orphan, Victoria J.
2016-01-01
Stable isotope probing (SIP) is a valuable tool for gaining insights into ecophysiology and biogeochemical cycling of environmental microbial communities by tracking isotopically labeled compounds into cellular macromolecules as well as into byproducts of respiration. SIP, in conjunction with nanoscale secondary ion mass spectrometry (NanoSIMS), allows for the visualization of isotope incorporation at the single cell level. In this manner, both active cells within a diverse population as well as heterogeneity in metabolism within a homogeneous population can be observed. The ecophysiological implications of these single cell stable isotope measurements are often limited to the taxonomic resolution of paired fluorescence in situ hybridization (FISH) microscopy. Here we introduce a taxonomy-independent method using multi-isotope SIP and NanoSIMS for identifying and grouping phenotypically similar microbial cells by their chemical and isotopic fingerprint. This method was applied to SIP experiments in a sulfur-cycling biofilm collected from sulfidic intertidal vents amended with 13C-acetate, 15N-ammonium, and 33S-sulfate. Using a cluster analysis technique based on fuzzy c-means to group cells according to their isotope (13C/12C, 15N/14N, and 33S/32S) and elemental ratio (C/CN and S/CN) profiles, our analysis partitioned ~2200 cellular regions of interest (ROIs) into five distinct groups. These isotope phenotype groupings are reflective of the variation in labeled substrate uptake by cells in a multispecies metabolic network dominated by Gamma- and Deltaproteobacteria. Populations independently grouped by isotope phenotype were subsequently compared with paired FISH data, demonstrating a single coherent deltaproteobacterial cluster and multiple gammaproteobacterial groups, highlighting the distinct ecophysiologies of spatially-associated microbes within the sulfur-cycling biofilm from White Point Beach, CA. PMID:27303371
HexSim version 2.0 is soon to be released by EPA's Western Ecology Division (WED). More than three years of work have gone into the development of this tool, which grew out of an EPA model called PATCH. HexSim makes it possible for non-programmers to develop sophisticated simula...
HexSim - A general purpose framework for spatially-explicit, individual-based modeling
HexSim is a framework for constructing spatially-explicit, individual-based computer models designed for simulating terrestrial wildlife population dynamics and interactions. HexSim is useful for a broad set of modeling applications. This talk will focus on a subset of those ap...
Reconstruction of radial thermal conductivity depth profile in case hardened steel rods
NASA Astrophysics Data System (ADS)
Celorrio, Ricardo; Mendioroz, Arantza; Apiñaniz, Estibaliz; Salazar, Agustín; Wang, Chinhua; Mandelis, Andreas
2009-04-01
In this work the surface thermal-wave field (ac temperature) of a solid cylinder illuminated by a modulated light beam is calculated first in two cases: a multilayered cylinder and a cylinder the radial thermal conductivity of which varies continuously. It is demonstrated numerically that, using a few layers of different thicknesses, the surface thermal-wave field of a cylindrical sample with continuously varying radial thermal conductivity can be calculated with high accuracy. Next, an inverse procedure based on the multilayered model is used to reconstruct the radial thermal conductivity profile of hardened C1018 steel rods, the surface temperature of which was measured by photothermal radiometry. The reconstructed thermal conductivity depth profile has a similar shape to those found for flat samples of this material and shows a qualitative anticorrelation with the hardness depth profile.
NASA Astrophysics Data System (ADS)
Matsubara, Atsuko; Kojima, Hisao; Itoga, Toshihiko; Kanehori, Keiichi
1995-08-01
High resolution depth profiling of arsenic (As) implanted into silicon wafers by a chemical technique is described. Silicon wafers are precisely etched through repeated oxidation by hydrogen peroxide solution and dissolution of the oxide by hydrofluoric acid solution. The etched silicon thickness is determined by inductively-coupled plasma atomic emission spectrometry (ICP-AES). Arsenic concentration is determined by hydride generation ICP-AES (HG-ICP-AES) with prereduction using potassium iodide. The detection limit of As in a 4-inch silicon wafer is 2.4×1018 atoms/cm3. The etched silicon thickness is controlled to less than 4±2 atomic layers. Depth profiling of an ultra-shallow As diffusion layer with the proposed method shows good agreement with profiling using the four-probe method or secondary ion mass spectrometry.
NASA Astrophysics Data System (ADS)
Garvelmann, J.; Külls, C.; Weiler, M.
2011-10-01
Predicting and understanding subsurface flowpaths is still a crucial issue in hydrological research. We present an experimental approach to reveal present and past subsurface flowpaths of water in the unsaturated and saturated zone. Two hillslopes in a humid moutainous catchment have been investigated. The H2O(liquid) - H2O(vapor) equilibration laser spectroscopy method was used to obtain high resolution δ2H vertical depth profiles of porewater at various points along a fall line of a pasture hillslope in the southern Black Forest, Germany. The Porewater Stable Isotope Profile (PSIP) approach was developed to use the integrated information of several vertical depth profiles of deuterium along two transects at the hillslopes. Different shapes of depth profiles were observed in relation to hillslope position. The statistical variability (inter-quartile range and standard deviation) of each profile was used to characterize different types of depth profiles. The profiles upslope or with a weak affinity for saturation as indicated by a low topographic wetness index preserve the isotopic input signal by precipitation with a distinct seasonal variability. These observations indicate mainly vertical movement of soil water in the upper part of the hillslope before sampling. The profiles downslope or at locations with a strong affinity for saturation do not show a similar seasonal isotopic signal. The input signal is erased in the foothills and a large proportion of pore water samples are close to the isotopic values of δ2H in stream water during base flow. Near the stream indications for efficient mixing of water from lateral subsurface flow paths with vertical percolation are found.
NASA Astrophysics Data System (ADS)
Richter, D., Jr.; Bacon, A. R.; Brantley, S. L.; Holbrook, W. S.
2015-12-01
To understand the relationship between geophysical measurements and chemical weathering at Earth's surface, we combine comprehensive chemical and physical analyses of a 70-m granite weathering profile in the Southern Piedmont in the southeastern United States. The research site is in the uplands of the Calhoun Critical Zone Observatory and is similar to many geomorphically stable, ancient, and highly-weathered Ultisol soils of the region. Surface and downhole geophysical analyses suggest significant physical changes to depths of about 40 m, where geophysical properties are consistent with competent and unweathered granite. At this depth, surface refraction velocities increase to >4.5 km/s; variations in downhole sonic velocities decrease by more than two-fold; and deviations in the downhole caliper log sharply decrease as well. Forty meters depth is also the depth of initiation of plagioclase feldspar weathering, as inferred from bulk geochemical measurement of the full 70-m deep core. Specifically, element-depth profiles, cast as mass transfer coefficient profiles using Ti and Zr as immobile elements, document inferred loss of plagioclase in the depth interval between 15 and 40-m depth. Plagioclase feldspar is the most abundant of the highly reactive minerals in the granite. Such a wide reaction front is characteristic of weathering granites. Some loss of K is observed at these depths but most K loss, as well as Mg loss, occurs at shallower depths. Nearby geophysical profiles and 3D stress models have been interpreted as showing that seismic velocities decrease at 40 m depth due to opening of fractures as rock is exhumed toward the surface. Given our interpretations of both the geochemical and geophysical data, we infer that the onset of chemical weathering of feldspar coincides with the opening of these fractures. The data highlight the ability of geochemistry and geophysics to complement each other and enrich our understanding of Earth's Critical Zone.
NASA Astrophysics Data System (ADS)
Rotella, H.; Caby, B.; Ménesguen, Y.; Mazel, Y.; Valla, A.; Ingerle, D.; Detlefs, B.; Lépy, M.-C.; Novikova, A.; Rodriguez, G.; Streli, C.; Nolot, E.
2017-09-01
The optical and electrical properties of transparent conducting oxide (TCO) thin films are strongly linked with the structural and chemical properties such as elemental depth profile. In R&D environments, the development of non-destructive characterization techniques to probe the composition over the depth of deposited films is thus necessary. The combination of Grazing-Incidence X-ray Fluorescence (GIXRF) and X-ray reflectometry (XRR) is emerging as a fab-compatible solution for the measurement of thickness, density and elemental profile in complex stacks. Based on the same formalism, both techniques can be implemented on the same experimental set-up and the analysis can be combined in a single software in order to refine the sample model. While XRR is sensitive to the electronic density profile, GIXRF is sensitive to the atomic density (i. e. the elemental depth profile). The combination of both techniques allows to get simultaneous information about structural properties (thickness and roughness) as well as the chemical properties. In this study, we performed a XRR-GIXRF combined analysis on indium-free TCO thin films (Ga doped ZnO compound) in order to correlate the optical properties of the films with the elemental distribution of Ga dopant over the thickness. The variation of optical properties due to annealing process were probed by spectroscopic ellipsometry measurements. We studied the evolution of atomic profiles before and after annealing process. We show that the blue shift of the band gap in the optical absorption edge is linked to a homogenization of the atomic profiles of Ga and Zn over the layer after the annealing. This work demonstrates that the combination of the techniques gives insight into the material composition and makes the XRR-GIXRF combined analysis a promising technique for elemental depth profiling.
Object Recognition in Flight: How Do Bees Distinguish between 3D Shapes?
Werner, Annette; Stürzl, Wolfgang; Zanker, Johannes
2016-01-01
Honeybees (Apis mellifera) discriminate multiple object features such as colour, pattern and 2D shape, but it remains unknown whether and how bees recover three-dimensional shape. Here we show that bees can recognize objects by their three-dimensional form, whereby they employ an active strategy to uncover the depth profiles. We trained individual, free flying honeybees to collect sugar water from small three-dimensional objects made of styrofoam (sphere, cylinder, cuboids) or folded paper (convex, concave, planar) and found that bees can easily discriminate between these stimuli. We also tested possible strategies employed by the bees to uncover the depth profiles. For the card stimuli, we excluded overall shape and pictorial features (shading, texture gradients) as cues for discrimination. Lacking sufficient stereo vision, bees are known to use speed gradients in optic flow to detect edges; could the bees apply this strategy also to recover the fine details of a surface depth profile? Analysing the bees’ flight tracks in front of the stimuli revealed specific combinations of flight maneuvers (lateral translations in combination with yaw rotations), which are particularly suitable to extract depth cues from motion parallax. We modelled the generated optic flow and found characteristic patterns of angular displacement corresponding to the depth profiles of our stimuli: optic flow patterns from pure translations successfully recovered depth relations from the magnitude of angular displacements, additional rotation provided robust depth information based on the direction of the displacements; thus, the bees flight maneuvers may reflect an optimized visuo-motor strategy to extract depth structure from motion signals. The robustness and simplicity of this strategy offers an efficient solution for 3D-object-recognition without stereo vision, and could be employed by other flying insects, or mobile robots. PMID:26886006
Object Recognition in Flight: How Do Bees Distinguish between 3D Shapes?
Werner, Annette; Stürzl, Wolfgang; Zanker, Johannes
2016-01-01
Honeybees (Apis mellifera) discriminate multiple object features such as colour, pattern and 2D shape, but it remains unknown whether and how bees recover three-dimensional shape. Here we show that bees can recognize objects by their three-dimensional form, whereby they employ an active strategy to uncover the depth profiles. We trained individual, free flying honeybees to collect sugar water from small three-dimensional objects made of styrofoam (sphere, cylinder, cuboids) or folded paper (convex, concave, planar) and found that bees can easily discriminate between these stimuli. We also tested possible strategies employed by the bees to uncover the depth profiles. For the card stimuli, we excluded overall shape and pictorial features (shading, texture gradients) as cues for discrimination. Lacking sufficient stereo vision, bees are known to use speed gradients in optic flow to detect edges; could the bees apply this strategy also to recover the fine details of a surface depth profile? Analysing the bees' flight tracks in front of the stimuli revealed specific combinations of flight maneuvers (lateral translations in combination with yaw rotations), which are particularly suitable to extract depth cues from motion parallax. We modelled the generated optic flow and found characteristic patterns of angular displacement corresponding to the depth profiles of our stimuli: optic flow patterns from pure translations successfully recovered depth relations from the magnitude of angular displacements, additional rotation provided robust depth information based on the direction of the displacements; thus, the bees flight maneuvers may reflect an optimized visuo-motor strategy to extract depth structure from motion signals. The robustness and simplicity of this strategy offers an efficient solution for 3D-object-recognition without stereo vision, and could be employed by other flying insects, or mobile robots.
Revisiting "Beyond Instructional Design"
ERIC Educational Resources Information Center
Sims, Rod
2015-01-01
Since the article "Beyond Instructional Design: Making Learning Design a Reality" (Sims, 2006) was published, much has changed in the opportunities we have for learning, and Professor Rod Sims's thinking has evolved. In this article, Professor Rod Sims reflects upon his original article, and he offers an evolved model of learning design,…
A novel ToF-SIMS operation mode for sub 100 nm lateral resolution: Application and performance.
Kubicek, Markus; Holzlechner, Gerald; Opitz, Alexander K; Larisegger, Silvia; Hutter, Herbert; Fleig, Jürgen
2014-01-15
A novel operation mode for time of flight-secondary ion mass spectrometry (ToF-SIMS) is described for a TOF.SIMS 5 instrument with a Bi-ion gun. It features sub 100 nm lateral resolution, adjustable primary ion currents and the possibility to measure with high lateral resolution as well as high mass resolution. The adjustment and performance of the novel operation mode are described and compared to established ToF-SIMS operation modes. Several examples of application featuring novel scientific results show the capabilities of the operation mode in terms of lateral resolution, accuracy of isotope analysis of oxygen, and combination of high lateral and mass resolution. The relationship between high lateral resolution and operation of SIMS in static mode is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hua, Xin; Szymanski, Craig; Wang, Zhaoying
2016-01-01
Chemical imaging of single cells is important in capturing biological dynamics. Single cell correlative imaging is realized between structured illumination microscopy (SIM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) using System for Analysis at the Liquid Vacuum Interface (SALVI), a multimodal microreactor. SIM characterized cells and guided subsequent ToF-SIMS analysis. Dynamic ToF-SIMS provided time- and space-resolved cell molecular mapping. Lipid fragments were identified in the hydrated cell membrane. Principal component analysis was used to elucidate chemical component differences among mouse lung cells that uptake zinc oxide nanoparticles. Our results provided submicron chemical spatial mapping for investigations of cell dynamics atmore » the molecular level.« less
Taylor, T; Massey, C
2001-01-01
Karl Sims' work on evolving body shapes and controllers for three-dimensional, physically simulated creatures generated wide interest on its publication in 1994. The purpose of this article is threefold: (a) to highlight a spate of recent work by a number of researchers in replicating, and in some cases extending, Sims' results using standard PCs (Sims' original work was done on a Connection Machine CM-5 parallel computer). In particular, a re-implementation of Sims' work by the authors will be described and discussed; (b) to illustrate how off-the-shelf physics engines can be used in this sort of work, and also to highlight some deficiencies of these engines and pitfalls when using them; and (c) to indicate how these recent studies stand in respect to Sims' original work.
Wind-farm simulation over moderately complex terrain
NASA Astrophysics Data System (ADS)
Segalini, Antonio; Castellani, Francesco
2017-05-01
A comparison between three independent software to estimate the power production and the flow field in a wind farm is conducted, validating them against SCADA (Supervisory, Control And Data Acquisition) data. The three software were ORFEUS, WindSim and WAsP: ORFEUS and WAsP are linearised solvers, while WindSim is fully nonlinear. A wake model (namely a prescribed velocity deficit associated to the turbines) is used by WAsP, while ORFEUS and WindSim use the actuator-disc method to account for the turbines presence. The comparison indicates that ORFEUS and WAsP perform slightly better than WindSim in the assessment of the polar efficiency. The wakes simulated with ORFEUS appear more persistent than the ones of WindSim, which uses a two-equation closure model for the turbulence effects.
Scalable and Axiomatic Ranking of Network Role Similarity
Jin, Ruoming; Lee, Victor E.; Li, Longjie
2014-01-01
A key task in analyzing social networks and other complex networks is role analysis: describing and categorizing nodes according to how they interact with other nodes. Two nodes have the same role if they interact with equivalent sets of neighbors. The most fundamental role equivalence is automorphic equivalence. Unfortunately, the fastest algorithms known for graph automorphism are nonpolynomial. Moreover, since exact equivalence is rare, a more meaningful task is measuring the role similarity between any two nodes. This task is closely related to the structural or link-based similarity problem that SimRank addresses. However, SimRank and other existing similarity measures are not sufficient because they do not guarantee to recognize automorphically or structurally equivalent nodes. This paper makes two contributions. First, we present and justify several axiomatic properties necessary for a role similarity measure or metric. Second, we present RoleSim, a new similarity metric which satisfies these axioms and which can be computed with a simple iterative algorithm. We rigorously prove that RoleSim satisfies all these axiomatic properties. We also introduce Iceberg RoleSim, a scalable algorithm which discovers all pairs with RoleSim scores above a user-defined threshold θ. We demonstrate the interpretative power of RoleSim on both both synthetic and real datasets. PMID:25383066
WholeCellSimDB: a hybrid relational/HDF database for whole-cell model predictions.
Karr, Jonathan R; Phillips, Nolan C; Covert, Markus W
2014-01-01
Mechanistic 'whole-cell' models are needed to develop a complete understanding of cell physiology. However, extracting biological insights from whole-cell models requires running and analyzing large numbers of simulations. We developed WholeCellSimDB, a database for organizing whole-cell simulations. WholeCellSimDB was designed to enable researchers to search simulation metadata to identify simulations for further analysis, and quickly slice and aggregate simulation results data. In addition, WholeCellSimDB enables users to share simulations with the broader research community. The database uses a hybrid relational/hierarchical data format architecture to efficiently store and retrieve both simulation setup metadata and results data. WholeCellSimDB provides a graphical Web-based interface to search, browse, plot and export simulations; a JavaScript Object Notation (JSON) Web service to retrieve data for Web-based visualizations; a command-line interface to deposit simulations; and a Python API to retrieve data for advanced analysis. Overall, we believe WholeCellSimDB will help researchers use whole-cell models to advance basic biological science and bioengineering. http://www.wholecellsimdb.org SOURCE CODE REPOSITORY: URL: http://github.com/CovertLab/WholeCellSimDB. © The Author(s) 2014. Published by Oxford University Press.